Wiring, Communication and Busbar System
Transcription
Wiring, Communication and Busbar System
Wiring, Communication and Busbar System For Motor Power-Starter Components Class 8502 CONTENTS Schneider Electric Brands Description Page Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 & 3 Components with Spring Terminals using QUICKFIT™ Technology . . . . . . . . . . 5 - 8 Communication Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 & 10 Choice of Connection between Module and PLC . . . . . . . . . . . . . . . . . . . . . . .11 & 12 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 - 16 Dimensions and Schematics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 - 23 AK5 Pre-Assembled Panel Busbar System . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 - 34 Wiring, Communication and Busbar System for Motor Power-Starter Components Motor Power-Starter Components MOTOR POWER-STARTER COMPONENTS Selection Guide LAD3• APP2R• APP2D•• Functions QUICKFIT™ technology for assembly and connection of motor starter components with spring terminals, without using tools. Types of product Power connection kit Power/control splitter box Control connection module · APP2R · LAD3 · LAD2 APP2D · For contactors D-Line Type of starter Non-reversing and reversing Non-reversing Reversing Coil control — With Relay With Relay Use with motor power-starters — 8 starters (1) — Number of motor power-starters 1 2, 3, 4 limited to 50 A 1 Connection of earth cables — — Connection via — HE10 connector or adaptor for communication module Type of connection or bus — Number of channels — Pages 8 (1) Without Relay Without Relay — With LAD3B upstream terminal block HP Ratings (maximum for a motor) 10 hp 2 480 V / 600 V 5 hp 220 V / 240 V 3 hp 208 V © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Motor Power-Starter Components Selection Guide APP1CH APP1CV/1CE APP1CAS2 APP1C••0/3 APP1C••2/5 AS-i bus Other buses AS-i 2 addresses CAM Open, Device Net Interbus S and S optical, Profibus DP and DP optical 8I/8O 16I/8O Communicate with the processing device (i.e. PLC) Communication modules · APP1C — — — — — — Connector to PLCs Terminal block HE10 Screw or spring 8I/8O 16I/8O 32I/24O 10 7/01 © 2001 Schneider Electric All Rights Reserved 3 Wiring, Communication and Busbar System for Motor Power-Starter Components Motor Power-Starter Components General Presentation: Power and Control Components QUICKFIT™ is a modular system which standardizes and simplifies the implementation of motor power-starters with its prewired control and power circuits. Hence, installation of a motor power-starter is quick, simple, and flexible with no wires needed for interconnection between devices. In addition, this system enables the motor power-starter to be customized at a later date. The system reduces maintenance time and optimizes panel space by reducing the number of terminals, the amount of ducting, and intermediate interfaces. The following solution is offered: • A solution using QUICKFIT™ technology for TeSys™ motor power-starter components with spring terminals: D-Line contactors (9 to 32 A) and the GV2ME motor manual starters. Tego Power Design definition software This software on CD-ROM enables the motor power-starter application to be graphically defined according to the manual starters and contactors used. It determines which Tego Power products are required for the application. Referencing labels can also be created for the starters. How to Build TeSys™ Motor Power-Starters with Spring Terminals The motor power-starters concerned are those formed by combining: • GV2M manual starters • with 9 to 32 A D-Line (LC1) contactors Consisting of simple parts, Tego Power QUICKFIT™ technology is used to create motor starter assemblies up to 20 hp/ 460 V (15 kW/400 V). 4 f LAD31 2 · 5 LAD3B APP2R 7 3a LAD34 3b 6 ♦ For the power circuit: • a power kit comprising, for each starter, a plate (4) for mounting the contactor and the manual starter, and the two power connection modules (3a, 3b) • a power splitter box (1) for 2, 3 or 4 starters • an upstream terminal block (5) for a power supply up to 63 A (16 mm2) • a downstream terminal block (6) for connecting the motor power supply cables and the earth cables (6 mm2 ) For the control circuit: • a control splitter box (2) for 2, 3, or 4 starters, with control-command data on HE10 connector. The data on 4 to 8 starters can be fed back directly to the PLC via an 8I/8O or 16I/8O Telefast cable or to a fieldbus module (Device Net, CAN Open, AS-i, FIP, Interbus, Profibus) See page 3. • a control circuit connection module (7) which plugs directly into the contactor and the manual starter. This module concentrates the motor starter control-command data. It integrates the manual starter status data in the prewiring of the contactor control circuit. • contactor coil control voltage is limited to AC 12 to 240 volts, or DC 24 to 125 volts when using control connection module with electromechanical relay APP2D• and DC 24 to 48 volts when using control connection module without electromechanical relay APP2D•D. LAD32 1 LAD33 The main components which make up this range are: · APP2D LAD35 kit contains one LAD31 mounting plate, and two LAD34 power connection modules. General Presentation: Communication Modules General Communication modules are used to send I/O data from a QUICKFIT™ motor power-starter configuration to the PLC. The communication modules are selected according to the type of connection required (see page 9): • parallel mode (modules, terminal blocks, or HE10) • serial mode via the bus (CAN Open, Device Net, AS-i bus, Interbus S, or Profibus DP modules) The communication modules are the same, whether the TeSys™ motor power-starter system uses spring or screw terminals. How to Build TeSys™ Motor Power-Starter System with Communication Modules 9 · APPIC 8 2 APP2CX APP2R · f Motor power-starters can be connected to a PLC or a bus in two ways: • by direct connection from the control circuit splitter box (2) with 4 starters, with an HE10 connector (8I/8O), or two HE10 connectors (16 I and 8 O) • by a communication module (9) using an APP-2CX adaptor plate (8) 4 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Components for Spring Terminals using QUICKFIT™ Technology COMPONENTS WITH SPRING TERMINALS USING QUICKFIT™ TECHNOLOGY Description: Power Connectors The motor power-starters concerned are those created by combining: • • Telemecanique GV2 manual starters (mainly GV2ME) with an operating limit of 80% of full load current at 60°C ambient temperature, up to 690 V (see page 14). with 9 to 32 A Telemecanique D-Line contactors (LC1). The main components which make up this range are: For the power part: • power kits • power splitter boxes • upstream and downstream terminal blocks For the control-command part: • power and control splitter boxes • control connection modules Used with communication modules (see pages 4 and 9), these motor power-starters exchange control-command data with PLCs or a bus. They can also communicate directly with PLCs via a Telefast HE10 cable. How to Assemble Power Components 1 LAD32 4 · Power kits LAD3• Each motor power-starter requires a power kit which consists of a plate (4) and 2 QUICKFIT™ technology power connection modules (3a, 3b). The plate is used for mounting TeSys™ D-Line contactors (13), with spring terminals, non-reversing or reversing, equipped with an AC or DC coil, 9 to 32 A, and the GV2ME4 manual starter only. This plate is mounted on a 35 mm omega rail or screwed onto a base plate. The two power connection modules (3a and 3b) are identical regardless of the rating of the contactor, up to 32 A. The lower power connection module (3b) connects the power between the contactor and the manual starter. The upper power connection module (3a) connects the power between the splitter box (1) and the manual starter (12). 5 LAD38 f LAD31 12 3a GV2... LAD34 3b 13 LC1D... 6 LAD33 ♦ 7/01 Splitter box LAD32• Splitter boxes (1) are available for 2, 3, or 4 starters. They can be combined to create motor power-starters up to 63 A per power supply. A reversing starter occupies a width equivalent to that of 2 direct starters. Direct supply of power to the splitter boxes is possible up to 25 A, 12 AWG (4 mm2). Upstream terminal block LAD3B The upstream terminal block (5) performs two functions: • power supply up to 63 A, 6 AWG (16 mm2). • power supply between two connected splitter boxes The upstream terminal block plugs into the splitter box using QUICKFIT™ technology. It is positioned on the splitter box or straddling the two splitter boxes, and takes up a width equivalent to two motor power-starters. Downstream terminal block LAD33 The downstream terminal block (6) performs two functions: • connects motor power supply cables up to 10 AWG (6 mm2). • connects the motor earth cables In addition, the terminal block enables quick connection and disconnection for maintenance, avoiding the risk of phase reversal. The downstream terminal block plugs into the down-stream spring terminals on the contactor using QUICKFIT™ technology. LAD35 kit contains one LAD31 mounting plate, and two LAD34 power connection modules. © 2001 Schneider Electric All Rights Reserved 5 Wiring, Communication and Busbar System for Motor Power-Starter Components Components for Spring Terminals using QUICKFIT™ Technology Description: Control Connection Modules 1 2 LAD32 APP2R · 7 APP2D · 7a 7b Power and control splitter boxes APP2R•• These have the same specifications as the power splitter box (1) described on page 5. They are used to gather control-command data from the motor power-starters. Power and control splitter boxes (1, 2) for 2, 3, or 4 starters can be combined to create up to 8 starters. A reversing starter takes up the space of two direct starters. The mechanical assembly of two splitter boxes connects the control-command data and the power supply to the coil control. The coil control can be AC or DC, up to 250 V. Three types of splitter boxes are available: • • • APP2R•E with one 30-way HE10 connector for connection to the APP1C• communication module, using the APP2CX adaptor plate (these splitter boxes are also available for 2 or 3 starters) APP2R4H1 with one HE10 connector with 8I/8O, for direct connection to the PLC via a Telefast cable: the data communicated to the PLC for each starter is the coil control (1 output) and the contactor status (1 input), for up to 8 starters APP2R4H2 with two HE10 connectors (one for 16 inputs, the other for 8 outputs) for direct connection to the PLC via a Telefast cable: the data communicated to the PLC for each starter is the coil control (1 output), the contactor status (1 input) and the manual starter status (1 input), for up to 8 starters The range is completed by splitter boxes which have an APP2R•AS AS-i bus link. Parallel link splitter boxes can be connected together up to 63 A, with no limit to the number of starters. Two types of splitter boxes are available specifically for AS-i: • 2 starters, 2I/1O per APP2R2AS starter: the data communicated to the PLC for each starter is the coil control (1 output), the contactor status (1 input) and the circuit-breaker status (1 input) • 4 starters, 1I/1O per APP2R4AS starter: the data communicated to the PLC for each starter is the coil control (1 output), the contactor status (1 input). Control splitter boxes (1) are also available on their own, as replacement parts. They are mounted, by the user, on LAD32• power splitter boxes. Control circuit connection modules APP2D•• The control circuit connection module (7) plugs directly into the control terminals on the GV2 manual starter and the contactor, using QUICKFIT™ technology. It connects to the control splitter box (2) via its upper part. Mechanical locking ensures good quality connections and a firm hold. It is compatible with all contactor ratings up to 32 A. These modules are available in 4 versions: with or without a contactor coil control relay, and non-reversing or reversing starter. The version without a relay is designed to control the contactor coils with no interface, generally at 24 Vdc. The connection module integrates, in its lower part, the external shunt (7a) for connecting an external contact in series with the contactor coil or forced local control (according to the schematics on pages 18 & 19). The second item of contactor status data is available on a connector (7b) which is left to the choice of the user. 6 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Components for Spring Terminals using QUICKFIT™ Technology Selection: Control Splitter Boxes for Various Connection Types Three types of splitter boxes are available, depending on the required connection to the PLC: • • • Direct connection to the PLC via HE10 connector and Telefast cable Connection to the control system via communication module Connection to the control system via AS-i bus Direct Connection via 8I/8O HE10 Connector An HE10 connector, on the top of the APP-2R4H1 control splitter box (1), provides the contactor status (1 input) and the coil control (1 output) for each starter. This HE10 connector can feed data back to up to 8 starters. The Telefast cable (3) is chosen according to the PLC environment (see pages 11 and 12). 2 11 8E/8S 11 API HE10 2 8E/8S 11 HE10 APE1R1628 11 16E 16S 11 API 11 Direct Connection via 16I/8O HE10 Connectors Two HE10 connectors, on the top of the APP2R4H2 control splitter box (2), provide the circuit-breaker status (1 input), the contactor status (1 input) and the coil control (1 output) for each starter. These HE10 connectors can feed data back to up to 8 starters. The Telefast cables (3) are chosen according to the PLC environment (see pages 11 and 12). 11 11 16E 11 11 API HE10 2 HE10 8S 11 2 ABE7ACC02 16 S 11 API Connection via Communication Module APP1C••• 2 9 8 The APP2R•E control splitter boxes (2) (2, 3, or 4 starters) are connected to the PLC via a Tego module APP1C••• (9). An APP2CX adaptor (8) must be used to connect the module to the control splitter box. These modules can feed data back to up to 8 starters. The module is selected according to the type of connection required: terminal block, HE10 connector, or bus (see page 9). The advantages of using Tego modules are: - the ability to use terminal block connection, - when connecting using an APP1CH HE10 connector and APP1CAS2 AS-i connector, it is possible to choose, for each starter, feedback of the status either of the contactor, or the circuit-breaker, and to use the available I/O for external data, if there are fewer than 8 starters, or to access the Interbus S, Profibus DP, CAN Open, Device Net buses. Direct Connection via AS-i bus, with no Communication Module There are two versions for direct connection of the control splitter box to the AS-i bus: • APP2R2AS splitter box for 2 starters, providing the circuit-breaker status (1 input), the contactor status (1 input) and control of the coil (1 output) for each starter • APP2R4AS splitter box for 4 starters, providing the contactor status (1 input) and control of the coil (1 output) for each starter In both cases, it is possible to connect as many starters as required, up to 50 A. 7/01 © 2001 Schneider Electric All Rights Reserved 7 Wiring, Communication and Busbar System for Motor Power-Starter Components Components for Spring Terminals using QUICKFIT™ Technology Splitter Boxes (refer to items 1 & 2 in the drawing on pages 4 & 5) Description Type of Control-cmd Connection on Control System Side No. of I/O per Starter 50 A power splitter box — — 1 x HE10 8I/8O (1) 1 x HE10 16I and 1 x HE10 8O (1) APP2R4H1 50 A power and control splitter box No. of Starters per Unit Catalog Number Weight lb. (kg) 1I/1O 2 4 4 LAD322 LAD324 APP2R4H1 0.26 (0.120) 0.53 (0.240) 0.77 (0.348) 2I/1O 4 APP2R4H2 0.79 (0.358) 2 4 2 4 APP2R2E APP2R4E APP2R2AS APP2R4AS 0.40 (0.178) 0.77 (0.348) 0.44 (0.200) 0.83 (0.380) Via module APP1C••• (2) — AS-i (3) 2I/1O 1I/1O Splitter Box Extension A total of up to eight starters is permissible after extensions. (a) LAD322, LAD324, APP2R4H1, APP2R4H2, APP2R2E, APP2R4E: Use similar module for extension. It can be for 2 or 4. Starter capacity as per need. Example: For extending LAD322, one or more of LAD322 can be used. (b) APP2R2AS, APP2R4AS: Use similar module for extension. Example: For extending APP2R2AS, use another APP2R2AS. Power Connection Components for One Starter (refer to items 3 & 4 in the drawing on pages 4 & 5) Description Assembly and power connection kit LAD35 Reversing kit (4) Kit Consists of: Catalog Number Weight lb. (kg) 1 LAD31 plate for GV2ME and 2 LAD34 power connection modules 1 set of busbars and 1 mechanical interlock LAD35 0.20 (0.078) LAD32 0.09 (0.040) Power Connection Accessories for One Starter (refer to items 5 & 6 in the drawing on pages 4 & 5) LAD3B Description Max. Connection Cross-Section Upstream terminal block (50 A max) 16 mm2 (6 AWG) Downstream terminal block (50 A max) 6 mm2 (10 AWG) Weight lb. (kg) Use Catalog Number Power supply of 1 or 2 power splitter boxes or power control splitter box Connection of motor cables LAD3B 0.47 (0.212) LAD33 0.11 (0.050) Control Connection Module for One Starter Description LAD33 Control connection module (integrating contact block GVAE20) D-Line Coil Voltage Type of Coil Control Relay Type of Starter Catalog Number Weight lb. (kg) ac 12 to 240 V or dc 24 to 125 V Electromechanical (5) dc 24 to 48 V Without relay (6) Direct Reversing Direct Reversing APP2D1 APP2D2 APP2D1D APP2D2D 0.26 (0.120) 0.51 (0.230) 0.24 (0.110) 0.48 (0.220) Spare or Replacement Parts (refer to item 7 in the drawing on pages 4 & 4) Description Plate for mounting a GV2ME manual starter Power connection module Control-command splitter box (single, for mounting on a power splitter box) APP2D1• 8 Type of Control-cmd Connection on Control System Side No. of I/O per Starter No. of Starters Sold in Lots of Unit Weight Catalog Number lb. (kg) — — 1 10 LAD31 — — 1 10 LAD34 0.04 (0.018) 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O 1I/1O 4 1 APP2R4H3 0.24 (0.108) 2I/1O 4 1 APP2R4H4 0.26 (0.118) 2 4 2 4 1 1 1 1 APP2R2C APP2R4C APP2R2A APP2R4A 1.30 (0.058) 0.24 (0.108) 1.8 (0.080) 0.31 (0.140) Per module APP1C••• (2) — AS-i (3) 2I/1O 1I/1O Replacement electromechanical relay (for — 1 10 APP2ER control connection module) (1) Cables with 20-way Telefast HE10 connector, in accordance with selection table on page 12. (2) Connection to an APP-1C••• module via APP-2CX adaptor (see page 10). (3) Available 1st quarter 2002. (4) To create a D-Line reverser, use 2 LC1-D contactors, 1 assembly and power connection kit and 1 reversing kit. (5) Relay supplied mounted on the front panel of the control connection. (6) The use of D-Line low consumption contactors is recommended. © 2001 Schneider Electric All Rights Reserved 0.10 (0.042) 0.02 (0.010) 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Selecting Communication Modules COMMUNICATION MODULES Selection: Communication Modules and Accessories PLC Selection of the communication modules depends on the type of connection required: • by removable screw or spring terminal blocks • parallel via HE10 connector and Telefast cable • serial via bus (AS-i bus, Interbus S and S optical, Profibus DP and DP optical, CAN Open or Device Net modules). In the QUICKFIT™ version (spring terminals), connecting a module to the APP2R power and control splitter box requires the fitting of an APP2CX adaptor. Terminal block connection APP1CV and APP1CE modules are 16 input/8 output - screw or spring - removable terminal block modules which can be used for wire-to-wire connection of data from the circuit-breaker and contactor contacts as well as the coil control outputs of each motor starter. The removable terminal blocks are supplied with the modules. Parallel connection via HE10 connector The APP1CH 1 module is an 8 input/8 output module, fitted with an HE10 connector for fast connection to PLCs using a prefabricated Telefast cable (see selection guide, page 11). Connection to a TSX Micro PLC is direct, using the TSX DMZ16DTK 8I/8O module 2 and the ABFH20H••0 or TSX CDP••3 Telefast cable 3. Serial connection via bus ABF• The APP1CAS2 AS-i module is an 8 input/8 output module on AS-i bus (2 addresses). The APP1CIB0 Interbus S and APP1CIB3 Interbus S fibre optic modules, APP1CPF0 Profibus DP and APP1CPF3 Profibus DP fibre optic modules, APP1CCO0 CAN Open and APP1CDN0 Device Net modules are 16 input/8 output modules for connecting APP1B• sub-bases. The APP1CIB2 Interbus S and APP1CIB5 Interbus S fibre optic, APP1CPF2 Profibus DP and APP1CPF5 Profibus DP fibre optic, and APP1CCO2 CAN Open and APP1CDN2 Device Net modules are 32I/24O modules in total, i.e.: • 16 inputs/8 outputs for connecting APP1B• sub-bases with up to 8 starters • an additional 2 x 8I/8O available on 2 HE10 connectors 4 compatible with the Telefast cables, and therefore with the APP1CH HE10 module 1 and with the ABE7H16CM•1 or ABE7•16M111 Telefast 8I/8O sub-base or the APE1B24M Tego Dial sub-base. 4 1 1 ABE7 8 starters 8 starters 3 8 starters ··· or APE1B24M 3 3 APP1• Notes on 8 input/8 output modules The APP1CH (HE10 connector) and APP1CAS2 (AS-i 8I/8O) modules are fitted with a 4-switch system for making the following selections: • switches C and D: option to feed back to the PLC either data from the circuit-breaker contact, or from the contactor on each of the 8 starters • switch E: an external input can be selected for each of the 4 end starters (nos 5 to 8) if the starter is not being used • switch F: an external output can be selected for each of the 4 end starters (nos 5 to 8) if the starter is not being used The position of switches C, D, E, F can be defined using Tego Power Design software. Communication Module Selection Table Type of Connection Number of I/O Available for APP1B• Sub-base Number of HE10 Connectors (1) Number of I/O per HE10 Catalog Number HE10 connector 8I/8O – – APP1CH Removable screw terminal block 16I/8O – – APP1CV Removable spring terminal block 16I/8O – – APP1CE ASi bus 8I/8O – – APP1CAS2 0 – APP1CIB0 2 8I/8O APP1CIB2 0 – APP1CIB3 2 8I/8O APP1CIB5 0 – APP1CPF0 2 8I/8O APP1CPF2 0 – APP1CPF3 2 8I/8O APP1CPF5 0 – APP1CCO0 2 8I/8O APP1CCO2 0 – APP1CDN0 2 8I/8O APP1CDN2 Interbus S bus Interbus S optical bus Profibus DP bus APP1CIB2 Profibus DP optical bus CAN Open bus Device Net bus (1) 7/01 16I/8O 16I/8O 16I/8O 16I/8O 16I/8O 16I/8O HE10 connector for connecting either the APP1CH module, an ABE7H16CM•1 or ABE7•16M111 Telefast sub-base, or the APE1B24M Tego Dial Dialbase interface. © 2001 Schneider Electric All Rights Reserved 9 Wiring, Communication and Busbar System for Motor Power-Starter Components Selecting Communication Modules Communication Modules (1) (refer to item 8 in the drawing on page 4) Weight lb. (kg) Screw APP1CV 0.86 (0.390) Spring APP1CE 0.78 (0.356) Type of Connection or Bus Communication modules with terminal block Communication modules with connector No. of HE10 Connectors (2) Catalog Number Description HE10 – APP1CH 0.75 (0.343) AS-i (3) – APP1CAS2 0.91 (0.416) – APP1CIB0 1.17 (0.530) 2 APP1CIB2 1.17 (0.530) – APP1CIB3 1.17 (0.530) 2 APP1CIB5 1.17 (0.530) – APP1CPF0 1.17 (0.530) 2 APP1CPF2 1.17 (0.530) – APP1CPF3 1.17 (0.530) 2 APP1CPF5 1.17 (0.530) – APP1CCO0 1.17 (0.530) 2 APP1CCO2 1.17 (0.530) – APP1CDN0 1.17 (0.530) 2 APP1CDN2 1.17 (0.530) Interbus S Interbus S optical APP1CH Communication modules via bus Profibus DP Profibus DP optical CAN Open Device Net Accessories for Communication Module (refer to item 8 on page 4 and the items on page 7) APE1R1628 ABE7ACC02 Description Specifications Order in Multiples of: Unit Catalog Number Weight lb. (kg) Adaptor For APP1C• communication modules 1 APP2CX 0.28 (0.130) HE10 intelligent splitter box 16 I/16 O (2 x 8 I/8 O) 24 V Ue/30 V max. Output type: 2.6 W tungsten filament lamp 1 APE1R1628 0.28 (0.130) Splitter subbase 16 channels (2 x 8) 1 ABE7ACC02 0.16 (0.075) Self-stripping connector (for external I/O on APP1CH and APP1CAS2 modules) 2 pin, 5 mm intervals Wire cross-section: 0.75 mm2 16 APE1PAD21 0.44 (0.020) Connector with vampire clip for AS-i bus Yellow 5 LA9Z32825 0.22 (0.100) Design Definition Software Description Language Support Version Catalog Number Weight lb. (kg) Definition software English and French CD-ROM 01 APP2C00M 0.22 (0.100) (1) Use adaptor APP2CX for connecting a QUICKFIT™ version module (spring terminals). (2) For connecting additional external I/O. APE1PAD21 10 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Choice of Connection between Module and PLC Choice of Connection between the Splitter Box Communication Module (APP1CH) and the PLC PLC Components Necessary for Connecting the PLC Brand/Type Connection Modularity 8 In + 8 Out Telemecanique Micro PLC Terminal Blocks — Compatible PLC Cards TSXDMZ16DTK Communication Module or Control Splitter Box with 8I/8O Control Splitter Telefast Cables Splitter Box Box 16I/8OO 16 In + 16 Out Splitter Box 16 (2x8) APP1CH or APP2R4H1/H3 APP2RH2/H4 ABE7ACC02 (2) 1 — 1 16 In + 16 Out Telemecanique TSX 47107 16 In + 16 Out Modicon Compact 984/ A120 16 In + 16 Out Modicon Quantum 32 In + 32 Out April 1 — TSXDEY32D2K/64D2K, TSXDSY32T2K/64T2K, TSXDEY16FK 1 — TSXBLK71 + TSXDET32••, TSXBLK91 + TSXDST3292 DA0216, DAP216/217, DE0216, DEP217/220, DEP216 1 — 1 1 — 8 In + 8 Out (included in Telefast cable) 4218MA12/4318MA11 4418MA11/4518MA11 16 In + 16 Out 6EP 5••••AA00 4828MA13 6EP 5••••1AA00 4207LA11, 4307LA12, 4417LA11, 4517LA11/21 1 4204UA14, 4304UA14, 4414UA14, 451UA14 1 3211B•0•0AA0, 3221B•0•0AA0 1 4211B•0•0AA0, 4221B•0•0AA0 1 Siemens 135/155U 8In + 8 Out Siemens S7300 8 In + 8 Out Siemens S7400 8 In + 8 Out 16 In + 8 Out 16 In + 8 Out 16 In + 16 Out 16 In + 16 Out 6EP 5••••1AA00 6ES79213AB0 00AA0 6ES79213AB0 00AA0 — 1 32 In + 32 Out (1) (2) — 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1746OB16/1746IB16 1 Allen Bradley SLC500 1 1 1 1 16 In + 16 Out 1 1 1 1 32 In + 32 Out 8 In + 8 Out 1 DDI353/853, DD0353 IDB3224, QDB3205, QPA3205 Siemens 115U 1 1 1 1 1 1 1 2 1 1 Siemens 95U/100U 2 1 1 — 1 TSXDMZ64DTK 1 Telemecanique Premium APE1R1628 (1) 1 1 16 In + 16 Out ABFH20H••0 TSX CDP••3 1746IB32, 1746OV32, 1746OB32 1 1 1 1 1 1 1 1 8 inputs + 8 outputs remain available. To connect a second APP1CH module or APP2••• 8 input + 8 output control splitter box, use an additional ABFH20H••0 or TSXCDP••4 cable. 8 outputs remain available on ABE7ACC02. To connect them to a second AAP2•••16 input/8 output control splitter box, use an additional ABFH20 ••0 or TSXCDP••3 cable. 7/01 © 2001 Schneider Electric All Rights Reserved 11 Wiring, Communication and Busbar System for Motor Power-Starter Components Choice of Connection between Module and PLC Telefast Cables for Connection to the PLC ABF H20H••0 or TSX CDP••• ABF H20H••1 ABF H28H••0 ABF H14H••0 ABF S16••H0 ABF ABF H40H••0 H40H••1 R16H••0 R16H••1 M16H••0 ABF ABF M16H••1 H32H••0 ABF H16H••0 ABF ABF M32H••0 A32H••0 2 1 2 1 2 2 1 1 1 1 2 2 2 2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12 1 1 1 1 1 1 1 1 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Specifications Specifications General Environment Type of Sub-base and Splitter Box APP-2R••, LAD-32• Standard IEC 60439-1 Approvals UL, CSA (pending) Degree of protection Conforming to IEC 60529 Resistance to incandescent wire Conforming to IEC 60695-2-1 Shock resistance Conforming to IEC 6068-2-27 IP 40 (mounted assembly) °F (°C) Vibration resistance Conforming to IEC 6068-2-6 and BV/LR Withstand to electrostatic discharges Conforming to IEC 61000-4-2 Withstand to radiated fields Conforming to IEC 61000-4-3 Immunity to rapid transients Conforming to IEC 61000-4-4 Surge withstand Conforming to IEC 61000-4-5 Kv Immunity to radio electrical fields Ambient air temperature Space required around mounted assembly 1760 (960) 11 ms and 15 gn (half sinewave) gn 5…300 Hz: 4 and 3…100 Hz: 0.7 Level 3 V/m 10 (26…1000 MHz) Level 3 2 in common mode, 0.6 in differential mode Wave form: 1.2/50 µs - 8/20 µs Conforming to IEC 61000-4-6 V 10 (0.15 to 80 MHz) Operation in floor-standing enclosure °F (°C) 23 to 140 (- 5 to + 60) Operation in wall-mounted enclosure °F (°C) 23 to 104 (- 5 to + 40) Storage °F (°C) -40 to 158 (- 40 to + 70) For inserting cables and heat dissipation in (mm) > 1.2 (30) Degree of pollution 3 Fixing of the assembly 35 mm rail or 2 x Ø 5.5 mm screws per plate for GV2-ME Number of wires Voltage supply for power 3 Tightening torque lb-in (N•m) 19.4 (2.2) Flexible cable with end AWG (mm2) 6 (16) Flexible cable without end AWG (mm2) 4 (25) Solid cable AWG (mm2) 4 (25) Suitable wire cross-sections Number of wires Voltage supply for contactor coil control Connection of pins to the circuit-breaker or contactor terminals 2 Tightening torque lb-in (N•m) 7.0 (0.8) Flexible cable with end (maximum) AWG (mm2) 16 (1.5) Flexible cable without end (max.) AWG (mm2) 14 (2.5) Solid cable (maximum) AWG (mm2) 14 (2.5) power lb-in (N•m) 15.0 (1.7) control lb-in (N•m) 10.6 (1.2) Tightening torque 3-phase Power Circuit Specifications per power supply Conforming to IEC 60439-1 A 63 (single power supply to one or more sub-bases or splitter boxes) per sub-base Conforming to IEC 60439-1 A 50 Maximum current GV2 operating limit 80% of Imax at 60° C ambient temp. (see page 12) Maximum current per starter A 32 (for 16A and above, keep one blank slot on right and left sides) Insulation voltage V 750 Operating voltage V 690 U imp kV 6 Rated frequency Hz 50-60 Conditional rated short-circuit current Isc at 415 V Conforming to IEC 60439-1 kA 50 Permissible rated short time current Icw Conforming to IEC 60439-1 kA 9.1 (for 70 ms) V ac 5 to 250 V dc 5 to 250 Control Circuit Specifications Contactor coil control voltage 7/01 © 2001 Schneider Electric All Rights Reserved 13 Wiring, Communication and Busbar System for Motor Power-Starter Components Specifications GV2 Circuit-breaker Current Limitation at 60°C Ambient Temperature with QUICKFIT™ System Circuit-Breaker Catalog Number GV2 Rating (1) GV2ME06 1 - 1.6 A Maximum Current of GV2 with QUICKFIT™ System 1.28 A GV2ME07 1.6 - 2.5 A 2A GV2ME08 2.5 - 4 A 3.2 A GV2ME10 4 - 6.3 A 5A GV2ME14 6 - 10 A 8A GV2ME16 9 - 14 A 11.2 A GV2ME20 13 - 18 A 14.4 A GV2ME21 17 - 23 A 18 A Electromechanical Relay Specifications Type of connection block APP 1D1A, 1D2A, 1K1B, 1K2B, 1ER, 2D1, 2D2, 2ER Specifications of the Electromechanical Relay Control Circuit (PLC end) Rated voltage at Us V dc 24 Energization threshold at 40 °C V dc 19.2 Drop-out voltage at 20 °C V dc 2.4 Maximum operating voltage V dc 30 Maximum current at Us mA 15 Drop-out current at 20 °C mA 1 Maximum power dissipated at Us W 0.36 Disappearance of voltage ms 5 Specifications of the Electromechanical Relay Output Circuit Type of contact 1F Vac 250 Vdc 250 Operating current frequency Hz 50/60 Maximum current of the contact A 4 Between coil energization and closing of the contact ms 10 Between coil de-energization and opening of the contact ms 5 At no-load Hz 10 At Ie Hz Maximum switching voltage Other Specifications of the Electromechanical Relay Maximum operating time at Us (including bounce) Maximum switching frequency Mechanical durability In millions of operating cycles 0.5 20 Dielectric strength V 1000 (50/60 Hz) - 1 min Rated impulse withstand voltage kV 2.5 Primary/secondary rated insulation voltage V 300 24 V - DC13 A 0.6 230 V - AC15 A 0.9 Maximum current for 500,000 operations (1) Thermal release adjustment range. 14 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Specifications Specifications of Parallel Link Communication Modules and Control Splitter Boxes Type of Module APP1CV, APP1CE APP1CH APP2R4H1/H3 Inputs 16 8 8 APP2R4H2/H4 16 Outputs 8 8 8 8 Number of channels Display of supply voltages (V In, V Out) Input specifications Output specifications By LED By LED – – Supply voltage Vdc 24 24 24 24 Max. current per channel mA 20 20 20 20 Total max. current mA 320 160 160 320 Operating voltage V dc 24 dc 24 dc 24 dc 24 Max. current per channel mA 500 100 500 500 Total max. current A 1 1 2 2 1 (8I/8O) 1 (8I/8O) 1 (16I) and 1 (8O) Connection to the sub-base By 30-way, HE10 connector No. of 20-way HE10 connectors per Telefast cable – Connection of the 24 V supply By removable connector at intervals of 5.08 mm, provided Wire cross-section: 14 AWG (2.5 mm2) without end, 16 AWG (1.5 mm2 ) with end Tightening torque: 7.1 lb-in (0.8 N•m) Connection of external I/O By removing connector at intervals of 5.08 mm, not provided. Wire cross-section: 14 AWG (2.5 mm2) without end, 16 AWG (1.5 mm2) with end. Tightening torque: 7.1 lb-in (0.8 N•m) 7/01 © 2001 Schneider Electric All Rights Reserved 15 Wiring, Communication and Busbar System for Motor Power-Starter Components Specifications Communication via Bus Modules Type of Module Ambient air temperature °F (°C) APP1CAS2 APP1CIB0/3, APP1CCO0 APP1CPF0/3, APP1CDN0 APP1CIB2/5, APP1CCO2 APP1CPF2/5, APP1CDN2 32 to 131 (0 to + 55) 32 to 131 (0 to + 55) 32 to 131 (0 to + 55) Inputs 8 16 16 + (2 x 8 external on HE10) = 32 Outputs 8 8 8 + (2 x 8 external on HE10) = 24 Number of channels Power supply Via the AS-i bus External by removable connector at intervals of 5.08 mm Display By LED (I/O and power supply) By LED (I/O communication and faults) – Current drawn on the bus mA < 280 x 2 V 24 mA 5 per input V 24 mA – Inputs Outputs 50 per output (relay compulsory) 500 per output AS-i profile S7.0 x 2 – Connection to the sub-base By 30-way HE10 connector By 30-way HE10 connector Connection of external I/O – – APP1CIB0, AAP1CIB2: By 2-way removable connector at intervals of 0.2" (5.08 mm) Connection to the bus APP1CPF0, AAP1CPF2: APP1CC0•, AAP1CDN•: APP1CIB3, AAP1CIB5: APP1CPF3, AAP1CPF5: By 2 x 20-way HE10 connectors 2 shielded SUB-D 9 connectors: - male for signal input - female for signal output Shielded SUB-D 9 connector 5-way connector at intervals of 0.2" (5.08 mm). F-SMA fibre optic connector HP-SIMPLEX fibre optic connector Specifications of the Connection Kit Type of kit APP1EL Operating voltage Ue V 690 Max. current per phase A 32 Communing link For the coil control Operating voltage Ue V 250 Communing link for the I/O control Operating voltage Vdc 24 Communing link for the power 16 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Dimensions DIMENSIONS Adaptor APP2CX Splitter Sub-Base ABE7ACC02 A B 1.37 35 4.04 102.7 10.0 254 1.88 48 2.24 57 3.5 90 1.37 35 0.86 22 1.96 50 1.96 50 0.6 15 Intelligent Splitter Box APE1R1628 10 254 0.3 8 C 2.75 70 2.28 58 Communication Module APP1C••• 3.46 88 0.6 15 0.86 48 2.24 57 5.1 128.7 5.78 147 a APP a 1CAS2 1.37" (35 mm) 1CIB• 1.77" (45 mm) 1CPF• 1.77" (45 mm) 1CC0• 1.77" (45 mm) 1CDN• 1.77" (45 mm) 1.37 35 2 51 Dual Dimensions inches mm Mounted Assembly (for components with spring terminals, using QUICKFIT™ System) 9.01 229 9.72 247 10.94 278 5 4 3 2 6 12.52 318 5.90 150 1 2 1.37 35 7 5.78 147 4.44 113 7/01 Manual Starter Support Plate Power Connection Module Power Splitter Box Control Splitter Box Upstream Terminal Block Control Connection Module Downstream Terminal Block 3.60 91,5 1.37 0.62 35 16 b " (mm) b1 " (mm) + " (mm) 2 starters 3.54 (90) 5.55 (141) 4 starters 7.09 (180) 9.1 (231) 0.35 (9.09) 8 starters 14.9 (380) 16.18 (411) 0.63 (16.18) b b1 © 2001 Schneider Electric All Rights Reserved 0.21 (5.55) 17 Wiring, Communication and Busbar System for Motor Power-Starter Components Schematics SCHEMATICS APP2D1 Sx ac (N) dc (+) - Km1 21 13 22 14 0V E1 x - KM1 + VIn 13 24 14 23 C - Q1 E2 x ac dc (Ph) (-) APP2D1D (24 Vdc) Sx 21 13 22 14 E1 x - KM1 + VIn 13 23 C 14 24 - Q1 E2 x 0V 18 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Schematics APP2D2 Sx ac (N ) dc (+) 21 13 22 14 - Km1 - KM1 0V E1 x + VIn 14 24 23 13 C - Q1 E2 x ac (Ph ) dc (-) ac (N ) dc (+) Sx - Km2 21 13 22 14 0V E1 x Shunt - KM2 + VIn C APP2D2D (24 Vdc) Sx 21 13 22 14 E1 x - KM1 + VIn 14 24 23 13 C - Q1 E2 x 0v Sx Shunt 21 13 22 14 E1 x - KM2 + VIn C 7/01 © 2001 Schneider Electric All Rights Reserved 19 Wiring, Communication and Busbar System for Motor Power-Starter Components Schematics + – + – KmO.8 – Km8 – Km1 X3 KmO.1 – KM8 KMI.8 X2 – KM1 – Q8 QI.8 X1 KMI.1 – Q1 A QI.1 APP1CE and APP1CV Communication Modules V In X4 V Out B 24 V power supply: VIn: inputs Sub-base. VOut: outputs Communication module. Removable terminal block for connecting circuit-breaker contacts 1 to 8 (terminals QI.1 to QI.8). Removable terminal block for connecting contactor contacts 1 to 8 (terminals KMI.1 to KMI.8). Removable terminal block for connecting interface relays 1 to 8 (terminals KmO.1 to KmO.8). Removable terminal block for I/O 24 V power supply. A B X1 X2 X3 X4 X1 X2 0 V COM 24 V IN 24 V OUT 0 V COM 19 20 – KA8 0 V COM 24 V IN 18 0 V COM 20 17 0 V COM 24 V OUT 19 24 V IN X4 18 17 16 – KA4 – KA1 9 0 V COM 20 8 24 V OUT 19 – KA5 – Q8 0 V COM 18 X3 1 24 V IN 17 16 9 8 1 (1) – KM8 – Q5 – Q4 – KM5 A – KM4 – KM1 – Q1 Can Open APP1CCO2 and Device Net APP1CDN2 Communication Modules X5 B (1) A B X1 X2 X3, X4 X5 Can Open or Device Net bus Sub-base. Communication module. Removable terminal block, 5 pins, for connecting the bus. Address switch. 20-way HE10 connectors for connecting 8 external inputs and 8 external outputs. Removable terminal block, 4 pins, at intervals of 5.08 mm, for connecting the 24 V IN and 24 V OUT module power supplies. Profibus DP, APP1CPF2 Communication Module With the exception of X1 and X2 the scheme is identical to that shown above. IN OUT Interbus S, APP1CIB2 Communication Module With the exception of X1 and X2, the scheme is identical to that shown above. X1 X2 B X1 X2 X1 X2 B Male SUB-D connector for the Interbus S input. Female SUB-D connector for the Interbus S output. 20 X1 X2 Female SUB-D connector for the Profibus DP connection. Address switches. © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Schematics APP-1CH Communication Module, Scheme and Operating Principle Switches C and D are used to select feedback from the contactor or circuit-breaker contact (pins 1 to 8 on the HE10 connector) for each starter. In addition, on the last 4 starters, it is possible to choose between feedback from the contactor or circuit-breaker contacts and an external input (switch E and pins 5 to 8 on the HE10 connector). External inputs are connected to terminals I.4 to I.7. Interface relays are connected to pins 9 to 16 on the HE10 connector. For the last 4 starters, it is possible to choose either coil control (Km5 to Km8) or connection of local external outputs (terminals Q.4 to Q.7) using switch F – Km8 – Km5 – Km4 – Km1 – Q8 – Q5 – KM8 – KM5 – Q4 – Q1 – KM4 – KM1 . A C F D X2 + – + – – Q.7 – Q.4 + 0 V OUT 20 I.7 24 V OUT 19 + 0 V IN 18 + – + – X1 I.4 24 V IN 17 16 13 12 9 8 5 4 1 E X4 VIn X3 VOut B Local inputs 24 V power supply: VIn: inputs VOut: outputs Local outputs Option of connecting 4 local external inputs and 4 local external outputs: selection via switches F and E. APP-1CAS2, Communication Module, Scheme and Operating Principle C D – Km8 – Km5 – Km4 – Km1 – Q8 – KM8 – Q5 – KM5 – Q4 – KM4 – Q1 A – KM1 Same operating principle as the APP-1CH module: switches E and F are used to select the local I/O and switches C and D are used to select the contactor or circuit-breaker contact. With this module, the data is fed back to the PLC via the AS-i bus. F Local inputs A B X1 X2, X3 X4 C, D E F 7/01 AS-i + AS-i + X4 AS-i – – – O.8 X3 AS-i – X2 O.5 + I.8 + I.5 S8 S5 S4 S1 E5 – + E8 AS-i + AS-i – Bus AS-i B E4 E1 E Local outputs Option of connecting 4 local external inputs and 4 local external outputs: selection via switches F and E Sub-base. Communication module. 20-way HE10 connector. Removable terminal blocks, 8 pins, at intervals of 5.08 mm, for connecting 4 external inputs and 4 external outputs. Removable terminal blocks, 4 pins, at intervals of 5.08 mm, for the I/O 24 V power supply (APP-1CH) or for the AS-i bus (APP-1CAS2). Switches for selecting between feedback to the PLC from the circuit-breaker or contactor status contact for each of the 8 starters. Switch for each of the last 4 starters (5 to 8), for selecting between feedback to the PLC of the circuit-breaker or contactor status (result of switch D) or an external input (if the starter is not used). Switch for each of the last 4 starters (5 to 8), for selecting between controlling the contactor coil or an external output (if the starter is not used). © 2001 Schneider Electric All Rights Reserved 21 Wiring, Communication and Busbar System for Motor Power-Starter Components Communication Modules: Configuring Input and Output Switches Communication Modules: Configuring Input and Output Switches APP1CAS2 communication modules: procedure for configuring input switches C, D and E, and output switch F. The table below can be used to set the position of the switches on the front panels of the modules. Switch C Switch D Switch E Switch F Power-starter components 5 to 8 or Control of power-starter components 5 to 8 or Power-starter components 1 to 4 Power-starter components 5 to 8 external inputs external outputs DP No. 5 DP No. 6 DP No. 7 DP No. 8 DP W DP X DP Y DP Z DP No. 5 DP No. 6 DP No. 7 DP No. 8 or DP No. 1 DP No. 2 DP No.3 DP No. 4 or W or X or Y or Z or I5 or I6 or I7 or I8 or Q5 or Q6 or Q7 Q8 CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. W I5 X I6 Y I7 Z I8 Coil 5 Q5 Coil 6 Q6 Coil 7 Q7 Coil 8 Q8 0 v v v v v v v v v v v v v v v v 0 1 v v v v v v v v v v v v v v v v 1 2 v v v v v v v v v v v v v v v v 2 3 v v v v v v v v v v v v v v v v 3 4 v v v v v v v v v v v v v v v v 4 5 v v v v v v v v v v v v v v v v 5 6 v v v v v v v v v v v v v v v v 6 7 v v v v v v v v v v v v v v v v 7 8 v v v v v v v v v v v v v v v v 8 9 v v v v v v v v v v v v v v v v 9 10 v v v v v v v v v v v v v v v v 10 11 v v v v v v v v v v v v v v v v 11 12 v v v v v v v v v v v v v v v v 12 13 v v v v v v v v v v v v v v v v 13 14 v v v v v v v v v v v v v v v v 14 15 v v v v v v v v v v v v v v v v 15 Switch Positions Corresponding to Configuration Selected Input Data on the state of: 8 manual starters (1 to 8) 8 contactors (1 to 8) 4 circuit-breakers and 4 external inputs 4 contactors and 4 external inputs Switches C D E 0 15 0 15 0 15 Insignificant Insignificant 0 0 15 15 Output Control of: 4 motor power-starter 4 external outputs Switch F 0 15 Example of the Procedure to be used to Set the Display for Input Switches C, D and E, and Output Switch F 1 Select the required data on the 8 input channels and 4 output channels Input Channel 1 2 3 4 5 Data CB CB CB Contactor Contactor Then, in the table below: 6 CB 7 8 External External Output 5 6 Contactor CB 7 Contactor 2 Select the display for switch C, which is reserved for motor power-starter components 1 to 4 only. Shade in the 4 columns corresponding to the circuit-breaker for channels 1, 2 and 3, and to the contactor for channel 4. The horizontal line containing the four shaded indicates the number of switch C to be displayed: 8. 3 Select the display for switch D, for the motor power-starter components and external inputs 5 to 8. Shade in the 4 columns corresponding to the contactor for channel 5, to the circuit-breaker for channel 6, and the 2 columns for channels 7 and 8 (external inputs). The horizontal line containing the four shaded indicates the four display options for switch D as being: 1, 5, 9 or 13. 4 Select the display for switch E, for the last 4 inputs. Shade in columns W and X for channels 5 and 6, and columns I7 and I8 for external inputs 7 and 8. The horizontal line containing the four shaded indicates the number of switch E to be displayed: 12. 5 Select the display for switch F, for the 4 outputs. Shade in the 4 coil columns for channel 5, Q6 channel 6, coil channel 7, Q8 channel 8. The horizontal line containing the four shaded indicates the number of switch F to be displayed: 10. 8 CB 5 5 5 5 Switch C Power-starter components 1 to 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Switch E Power-starter components 5 to 8 or external inputs DP No. 1 DP No. 2 DP No. 3 DP No. 4 DP No. 5 DP No. 6 DP No. 7 DP No. 8 DP W DP X DP Y DP Z or W or X or Y or Z or I5 or I6 or I7 or I8 CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. CB Cont. W I5 X I6 Y I7 Z I8 v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Explanation of the Symbols Used: 22 Switch D Power-starter components 5 to 8 v v v v Coil = state of output to a coil contactor Q = state of output to any external circuit v v v v v Switch F Control of power-starter components 5 to 8 or external outputs DP No. 5 DP No. 6 DP No. 7 or Q5 or Q6 or Q7 Coil 5 Q5 Coil 6 Q6 Coil 7 Q7 v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v DP No. 8 or Q8 Coil 8 Q8 v v v v v v v v v v v v v v v v v I = external input DP W, DP X, DP Y, DP Z = input selected by the state of DP (CB or contactor) © 2001 Schneider Electric All Rights Reserved 7/01 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Wiring, Communication and Busbar System for Motor Power-Starter Components Schematics for using Components with Screw Terminals X Control-command circuit diagrams for a direct starter created using components with screw terminals. (conforming to standards “Low voltage installation regulations” C 15-100 and “Machine safety” NF EN 60205-1) 1 - Direct starter with relay and with front-mounted auxiliary contact GV-AE20. 2 - Direct starter without relay, with front-mounted auxiliary contact GV-AE20. U1 U1 (4) (4) – Km1 (3) (3) 13 X1 – KM1 – KM1 (5) 14 (2) 23 13 X4 – Q1 (4) U2 A B X4 24 14 24 14 – Q1 B (5) + VIn 13 + VIn – KM1 (2) 24 V 14 – KM1 13 (1) 23 X1 24 V (4) U2 A 3 - With forced local control, wired on shunt (3) - (APP-1//// D connection blocks not used GV-AE20 used). A shunt for forced local control can also be wired with APP-1//// D connection blocks U1 (4) (6) – Km1 X1 1 (1) 13 24 V 2 (7) (3) – KM1 – KM1 14 (2) (5) 13 23 + VIn X4 B 24 14 – Q1 (4) U2 A A B X1, X4 Q1 (1) (2) (3) (4) (5) (6) (7) Sub-base. Communication module. HE10 connector, removable terminal block (See below). Thermal-magnetic motor circuit-breaker. Km1: APP-1ER interface relay. KM1: contactor coil. External shunt on lower connection block. It can be used to connect an external input. To communication module. Control voltage of contactor coils. Control unit (optional) for forced local control. 2-position auto/manual selector switch (optional). Accessories for communication modules Intelligent splitter box APE-1R1628 7/01 1 8 9 16 17 18 19 20 8 9 16 17 18 19 20 16 17 18 19 20 8 9 X4 1 16 17 18 19 20 C 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 X3 B X2 1 16 17 18 19 20 9 8 X1 1 0 V OUT 0 V IN 24 V OUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A 24 V IN Splitter sub-base ABE7ACC02 © 2001 Schneider Electric All Rights Reserved 23 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5 GENERAL INFORMATION 2 3 1 4 5 5 5 1 2 8 10 11 12 6 9 8 6 7 13 10 24 15 12 © 2001 Schneider Electric All Rights Reserved 14 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System The assembly of automated control and distribution panels requires the use of products that are simple and quick to mount and cable. The AK5 pre-assembled busbar system meets these criteria by incorporating prefabricated elements which provide 3 principal functions: Current Supply Pre-assembled 160 A (at 35 °C) 4-pole busbar system (1). The busbar systems are available in 6 lengths: 344 (13.5"), 452 (17.8"), 560 (22"), 668 (26.3"), 992 (39"), and 1100 mm (43.3"). An incoming supply terminal block (2) is located at the extreme left of the busbar system. “Knock-out” partitions allow cabling from above or below to the terminal block connections (3), which are protected by a removable cover (4). Current Distribution The tap-offs (5) clip onto the busbar system with instantaneous mechanical and electrical connections to the busbar. Two ratings are available: 16 and 32 A. The tap-off units not only ensure rapid mounting but also provide visual “symmetry” for the power distribution circuit and complete safety when accessing under live circuit conditions. Component Mounting Component mounting plate incorporating electrical tap-off. — Tap-off rating: 25 A or 50 A. (No UL rating on 50 A) The mounting plates clip onto the mounting rail (11), which also supports the busbar system, and at the same time make electrical connection via the incorporated tap-off. Two types of mounting plates are available: — Single plate (6) height 4.14" (105 mm) with bolt-on 35 mm wide ( rail (7). This omega rail may be bolted in one of two positions, each with a 10 mm vertical step, — Double plate (8) and (14) height 7.48" (190 mm) with two bolt-on 35 mm wide ( rails (9) mounted on 100 mm mounting centers. Each rail may be bolted in one of four positions, each with a 10 mm vertical step. These mounting plates are supplied with connectors (12) to allow wiring between control and protection devices. Bolt-on width extension plates (10) are also available for mounting wider components. Using a lateral end stop (15) in conjunction with these plates also supports the AK5-JB busbar system when used vertically. A control terminal block (13), comprising of a support plate bolted onto the single or double mounting plates and a 10-pole plug-in block, enables connection of the control circuit wires, c.s.a. 16 AWG (1.5 mm 2 max.). NOTE: Numbers in (parenthesis) corresponds to the drawing on page 24. 7/01 © 2001 Schneider Electric All Rights Reserved 25 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5 SPECIFICATIONS Pre-assembled Panel Busbar System Characteristics Conforming to standards: Approvals EC 439 UL, CSA, DNV, LROS UL File Number E161251 CCN NMTR CSA File Number LR 89150 Class 6228 01 Degree of protection Against access to live parts IP XXB conforming to IEC 60529 Flame resistance - Conforming to IEC 60695 - Conforming to UL 94 850 (incandescent wire) V0 Number of conductors AK5JB14• °C 4 c Supply current Rated operational frequency Rated operational current Hz 50 or 60 Ambient air temperature 35 °C A 160 Derating coefficient K applicable to rated operational current °C 35 40 45 50 55 60 0.96 0.92 0.88 0.83 0.78 for ambient temperature greater than 35 °C K 1 - Conforming to IEC 60439-1 - Conforming to UL and CSA V V 690 600 - Conforming to IEC 60439-1 - Conforming to UL, CSA V V Off-load plugging-in and unplugging, with supply switched on 400 480 - Conforming to IEC 60439-1 - Conforming to UL, CSA V V Plugging-in and unplugging with supply switched off 690 600 Maximum permissible peak current kA 25 Maximum let-through energy A2 s 1 x 10 7 Rated insulation voltage Operational voltage Short-circuit (1) and overload protection Type of protection Square D circuit breaker (1) (2) 26 161H aM gF 160 160 160 100 Rating A 160 Prospective short-circuit current kA 25 50 100 Operational current A 160 160 160 Wiring Mounting position Fuses 161N 160 Maximum c.s.a. Minimum c.s.a. Flexible cable with cable end mm2 70 2.5 Solid cable mm2 70 2.5 Stranded cable AWG 2/0 8 Tightening torque N•m 10 N•m; 88 lb-in Horizontal or vertical (2) Fixing with screws supplied For conditions where conditional short-circuit current exceeds 25 kA. Using lateral end stop AK5BT01 in conjunction with mounting plates AK5PA. © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System Tap-off Characteristics Type AK5 PC12PH Conforming to standards IEC 60439 Approvals UL, LROS, CSA, DNV Degree of protection Against access to live parts: IP XXB conforming to IEC 60529 Polarity Phase + Phase 3-phase Phase + Phase 3-phase AWG (mm2) 2 x 14 (2 x 2.5) 3 x 14 (3 x 2.5) 2 x 12 (2 x 4) 3 x 12 (3 x 4) Black Black Black Black A 16 16 32 (25 A UL rated) 32 (25 A UL rated) Number of conductors and conductor c.s.a. (UL cables) Conductor colors Permissible current AK5 PC13 Rated insulation voltage V 690 conforming to IEC 60439-1 Rated peak current kA 6 Maximum let-through energy A2s 100,000 Conductor insulation AK5 PC32LPH AK5 PC33 PC33L 200,000 PVC 105 °C Mounting Plate/Tap-off Characteristics Type AK5 PA231 PA232 PA232S AK5 PA532 Conforming to standards IEC 60439 Approvals UL, LROS, CSA, DNV Degree of protection Against access to live parts: IP XXB conforming to IEC 60529 Polarity 3-phase 3-phase 3 x 12 (3 x 4) 2 x (3 x 12) 2 x (3 x 4) A 25 50 V 690 conforming to IEC 60439-1 Rated peak current kA 6 Maximum let-through energy A2 s 200,000 Number of conductors and conductor c.s.a. (UL cables) AWG (mm2) Permissible current Rated insulation voltage Conductor insulation PVC 105 °C Characteristics of Mounting Rails AM1DL201 and AM1DL2017 “Top hat” " (width 75 mm, depth 15 mm) Type Material 2.5/32" (2 mm) sheet steel Surface treatment Zinc chromate 7/01 © 2001 Schneider Electric All Rights Reserved 27 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5 APPLICATION INFORMATION AK5PA231 AK5PA232 AK5PA232S AK5PA532 Width in mm 54 54 108 108 Height in mm 105 190 190 190 No. of 18 mm pitches 3 3 6 6 Rated current 25A 25A 25A 50A (not UL rated for 50 A) Mounting Plate with Tap-off GV Manual Starters Number of 18 mm Pitches used on the Busbar System GV2•01 to •22 (up to 1 side-mount aux block) 3 – – – GV2•01 to •22 (up to 2 side-mount aux block or 1 side-mount trip unit) 4 – – – GV2•01 to •22 (up to 2 side-mount aux block and 1 side-mount trip unit) 5 – – – GV2M32, GV3M01 to M40 (no limit on sidemount aux blocks) – – – 6 GV2•01 to •20 (up to 1 side-mount aux block) + LC1D09 to D18 (no side-mount blocks) – 3 – – GV2•01 to •20 (up to 2 side-mount aux block or 1 side-mount trip unit) + LC1D09 to D18 (up to 2 LA8D••• block) – 4 – – GV2•01 to •20 (up to 2 side-mount aux block and 1 side-mount trip unit) + LC1D09 to D18 (up to 2 LA8D••• block) – 5 – – GV2•01 to •22 (up to 2 side-mount aux block or 1 side-mount trip unit) + LC1D09 to D18 (up to 2 LA8D••• block) ♦ – 4 – – GV2•01 to •22 (up to 2 side-mount aux block and 1 side-mount trip unit) + LC1D09 to D18 (up to 2 LA8D••• block) ♦ – 5 – – GV3M01 to M40 (with or without GV1•• aux) + LC1D09 to D32 (no LA8 aux) Mounted side by side – – – 7 GV3M01 to M40 with GV1•• + LC1D09 to D32 (with up to 1 LA8 aux) Mounted side by side – – – 8 GV2•01 to •20 (no limit on GV aux blocks) + LC2D09 to D18 (no side-mount blocks) – – 6 – GV2•01 to •20 (no limit on GV aux blocks) + LC2D09 to D18 (up to 1 LA8D••• block) – – 7 – GV2•01 to •20 (no limit on GV aux blocks) + LC2D09 to D18 (up to 2 LA8D••• blocks) – – 8 – GV2•01 to •22 (no limit on GV aux blocks) + LC2D25 to D32 (no side-mount blocks) ♦ – – 7 – GV2•01 to •22 (no limit on GV aux blocks) + LC2D25 to D32 (up to 1 LA8D••• block) ♦ – – 8 – GV2•01 to •22 (no limit on GV aux blocks) + LC2D25 to D32 (up to 2 LA8D••• blocks) ♦ – – 9 – GV Manual Starters + Contactor GV Manual Starters + Reversing Contactor ♦ 28 Applications up to 25A only. © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5PA231 AK5PA232 AK5PA232S AK5PA532 Width in mm 54 54 108 108 Height in mm 105 190 190 190 No. of 18 mm pitches 3 3 6 6 Rated current 25A 25A 25A 50A (not UL rated for 50 A) Mounting Plate with Tap-off Type of Starter Number of 18 mm Pitches Used on the Busbar System Integral 18 Starter LD1LB030 (no add-on blocks) 3 – – – LD1LB030 (up to 2 LA1LB add-on blocks) 4 – – – LD1LB030 (up to 3 LA1LB add-on blocks) 5 – – – LD4LC030 (no aux blocks) 4◆■ – – 6 LD4LC030 (up to 2 LA1LC aux blocks) ▲ 5◆■ – – 6 LD4LC030 (up to 3 LA1LC aux blocks) ▲ 6◆■ – – 6 LD4LC030 (up to 4 LA1LC aux blocks) ▲ 7◆■ – – 7 LD4LC030 (with 1 LA1LC01• aux block and 1 reset module LA1LC052•, and up to 1 LA1LC030 aux block) 7◆■ – – 7 LD4LC030 (with 1 LA1LC01• aux block and 1 reset module LA1LC052•, and up to 2 LA1LC030 aux block) 8◆■ – – 8 LD5LB130 – – 6 – LD5LB130 with up to 2 LA1LB add-on blocks – – 7 – LD5LB130 with up to 3 LA1LB add-on blocks – – 8 – Integral 32 ® Starter Reversing Integral 18 Starter ◆ ■ ▲ Applications up to 25 A only. Using AK5PE17 extension plate in combination with AK5PA231 mounting plate. Auxiliary block LA1LC010 counts as two normal auxiliary blocks. (It is twice the width of the other LA1LC blocks.) 7/01 © 2001 Schneider Electric All Rights Reserved 29 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System Maximum Number of Components per Busbar System Mounting Plate AK5 Bus-bar Used With JB143 JB144 JB145 JB146 JB149 JB1410 Integral 18 4 6 8 10 16 18 Integral 18 + 1 aux block 4 6 8 10 16 18 Integral 18 + 2 aux block 3 4 6 7 12 14 Integral 18 + 3 aux block 2 4 5 6 10 12 GV2 + up to 1 side-mount aux block 4 6 8 10 16 18 GV2 + up to 2 side-mount aux block or 1 side-mount trip unit 3 5 6 8 13 15 GV2 + up to 2 side-mount aux block and 1 side-mount trip unit 2 4 5 6 10 12 Integral 32 (no aux blocks) ◆ ■ 3 4 6 8 13 14 Integral 32 (1 aux block) ◆ ■ 2 4 5 6 10 12 Integral 32 (2 aux blocks) ◆ ■ 2 3 4 5 9 10 Integral 32 (3 aux blocks) ◆ ■ 2 3 4 5 8 9 Integral 32 (4 aux blocks) ◆ ■ 1 2 3 4 7 8 AK5PA231 AK5PA231 + AK5PE17 ◆ AK5PA532 AK5PA232 ▲ AK5PA232S ▲ ■ ◆ ▲ Integral 32 (with 1 LA1LC01• aux block and 1 reset module LA1LC052) ◆ 1 2 3 4 7 8 GV3 (no limit on side-mount aux blocks) 2 3 4 5 8 9 Integral 32 (up to 3 aux blocks) 2 3 4 5 8 9 Integral 32 (4 aux blocks) 1 2 3 4 7 8 Integral 32 (with 1 LA1LC01• aux block and 1 reset module LA1LC052) ◆ 1 2 3 4 7 8 GV2 + LC1D09 to D18 (no aux blocks) 4 6 8 10 16 18 GV2 + LC1D09 to D18 (up to 1 LA8D••• block) 3 5 7 9 15 16 GV2 + LC1D09 to D18 (up to 2 LA8D••• blocks) 3 4 6 7 12 13 GV2 + LC1D25 to D32 (up to 1 LA8D••• block) ◆ 3 4 6 7 12 14 GV2 + LC1D25 to D32 (up to 2 LA8D••• block) ◆ 2 4 5 6 10 12 GV2 + LC2D09 to D18 (no side-mount blocks) 2 3 4 5 8 9 GV2 + LC2D09 to D18 (up to 1 LA8D••• block) 1 2 3 4 7 8 GV2 + LC2D09 to D18 (up to 2 LA8D••• blocks) 1 2 3 4 6 7 GV2 + LC2D25 to D32 (no side-mount blocks) ◆ 1 2 3 4 6 7 GV2 + LC2D25 to D32 (up to 1 LA8D••• block) ◆ 1 2 3 3 6 6 GV2 + LC2D25 to D32 (up to 2 LA8D••• block) ◆ 1 2 2 3 5 6 Auxiliary block LA1LC010 counts as two normal auxiliary blocks. (It is twice the width of the other LA1LC blocks). Applications up to 25 A only. For installations using a GV plus a contactor mounted one above the other, follow the steps below for determining the maximum number of devices per busbar: 1. Determine how many GVs could be installed from the AK5PA231 section above. Be sure to properly select the number of side mounted auxiliaries that will be used. 2. Determine how many contactors could be installed from the AK5PA232 (for non-reversing contactors) or AK5PA232S (for reversing contactors) section above. Be sure to properly select the number of side mounted auxiliaries that will be used. 3. Choose the smaller of the two numbers from step 1 and 2. NOTE: For combinations of components not shown, refer to table on pages 28-29 to determine spacing required. 30 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5 SELECTION INFORMATION 160 Ampere Three Phase Busbar System Maximum Number of Tap-offs or Mounting Plates AK5JB143 Total Number of 18 mm “Pitches” 36 mm (3 phase) Tap-Offs Std (54 mm) Mounting Plate Double-width (108 mm) Mounting Plate Busbar Length in mm Catalog Number 12 6 4 2 13.39 344 AK5JB143 18 9 6 3 17.64 452 AK5JB144 24 12 8 4 21.85 560 AK5JB145 30 15 10 5 26.05 668 AK5JB146 48 24 16 8 38.69 992 AK5JB149 54 27 18 9 42.90 1100 AK5JB1410 Mounting Rail Must be used for Mounting Plate Tap-offs. AM1DL201 Description Material Depth (mm) Length (mm) Catalog Number 75 mm Omega Rail 2 mm steel with 10 microns of zinc chromate 15 2000 AM1DL201 Bus Tap-Offs Plugs into Busbar for Wiring to a Separately Mounted Device. Width Wire Length Sold in Lots Of Catalog Number 7.87 6 AK5PC13 9.84 6 AK5PC33 39.37 6 AK5PC33L Rated Current AK5PC33 (mm) (in) 36 1.42 36 1.42 36 1.42 (mm) (in) 16 A 200 32 A 250 32 A 1000 Mounting Plate Tap-Offs Combines a Bus Tap-off with a Prefabricated Mounting Plate for Convenient Mounting of Contactors, GV Manual Starters, and Integral Self-protected Starters. AK5PA231 Application Width (See page 30 for mounting restrictions) In (mm) Height In (mm) Number of DIN Rails Required Number of Rated 18 mm Spaces Current Catalog Number GV2 Manual Starter Integral 18 Starter 2.15 (54) 4.13 (105) 1 3 25 A AK5PA231 GV2 + Contactor 2.15 (54) 7.48 (190) 2▲ 3 25 A AK5PA232 GV2 + Reversing Contactor Reversing Integral 18 4.25 (108) 7.48 (190) 2▲ 6 25 A AK5PA232S Integral 32 Starter GV3 + LC1D Contactor (mounted side by side) 4.25 (108) 7.48 (190) 1 6 50 A AK5PA532 ▲ Mounting plate tap-offs with 2 DIN rails include a 25 A rated prefabricated connector for easily wiring the top component to the bottom component. AK5PA232S AK5PA532 7/01 © 2001 Schneider Electric All Rights Reserved 31 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System Extension Plate Used to Support Wider Components. Bolts onto Standard Width Plate, After Having Removed the DIN Rail. AK5PE17 Application Attach Mounting Plate Width In (mm) Height In (mm) Number of DIN Rails Number of 18 mm Spaces Required Catalog Number Integral 32 (for applications less than 25 A) AK5PA231 2.79 (71) 4.13 (105) 1 4 AK5PE17 GV2 + Contactor (with or without side-mounted auxiliaries) AK5PA232 2.79 (71) 7.48 (190) 2 4 AK5PE27 Side Stop Used to Secure Components on Mounting Plates when AK5 Busbar is Mounted Vertically. Description Sold in Lots Of Catalog Number Metal side stop clip 4 AK5BT01 AK5BT01 32 © 2001 Schneider Electric All Rights Reserved 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System AK5 DIMENSIONS 1.18 30 3.23 82 Busbar System AK5JB••• 1.77 45 3.19 81 3.11 79 G a a in (mm) G in (mm) No. of 18 mm Points JB143 13.54 (344) 12.99 (330) 12 JB144 17.80 (452) 17.24 (438) 18 JB145 22.05 (560) 21.50 (546) 24 JB146 26.30 (668) 25.75 (654) 30 JB149 39.06 (992) 38.50 (978) 48 JB1410 43.31 (1100) 42.76 (1086) 54 Mounting Plates Incorporating Tap-offs 25 A AK5PA231 AK5PC33 AK5PC33L 1.50 38 1.40 35.5 Single Width Extension Plates AK5PE17 2.09 53 (1) 4.13 105 4.13 105 2.09 53 (1) 0.39 10 0.39 10 0.59 15 1.81 46 2.13 54 AK5PC13 1.79 45.5 AK5 0.59 15 0.28 7 2.80 71 Dual Dimensions inches mm 7/01 © 2001 Schneider Electric All Rights Reserved 33 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System Z Mounting Plates Incorporating Tap-offs AK5PA232 Double Width Extension Plate AK5PE27 2.09 53 (1) 3.94 100 2.09 53 (1) 1.57 40 0.39 10 47 7.48 190 3.94 100 7.48 190 0.39 10 0.28 7 0.59 15 1.81 46 0.39 10 2.80 71 2.13 54 0.59 15 Mounting Plates Incorporating Tap-offs AK5PA232S AK5PA532 2.09 53 (1) 3.66 93 3.94 100 7.48 190 7.48 190 0.39 10 4.17 106 0.27 x 0.57 6.8 x 14.5 Ø 0.26 6.5 0.61 15.5 1.97 0.98 50 25 0.49 0.59 12.5 15 34 25.59 650 27.56 700 0.87 22 0.17 4.2 0.27 x 0.57 6.8 x 14.5 2.95 75 0.26 6.5 Side Stop AK5BT01 0.79 20 Mounting Rails AM1DL201 (length 2000 undrilled) AM1DL2017 Ø 4.17 106 2.48 63 0.03 0.8 2.48 63 28.54 725 29.53 750 © 2001 Schneider Electric All Rights Reserved 0.28 7 Dual Dimensions inches mm 7/01 Wiring, Communication and Busbar System for Motor Power-Starter Components Pre-Assembled Panel Busbar System NOTE: Related product catalogs for additional information are listed below: 8502CT9901 R2/01 2520CT0001 9421CT0001 7/01 IEC Contactors and Starters Manual Motor Starters, Controllers and Protectors, Type GV2, GV3, and GV7 Manual Control Switches and Disconnects, Type Vario GS1, and LK3 © 2001 Schneider Electric All Rights Reserved 35 Square D Company 8001 Highway 64 East Knightdale, NC 27545 USA 1-888-SquareD (1-888-778-2733) www.squared.com Schneider Canada Inc. 19 Waterman Avenue, M4B 1 Y2 Toronto, Ontario 1-800-565-6699 www.schneider-electric.ca Catalog No. 8502CT0101 July 2001 © 2001 Schneider Electric All Rights Reserved