CONTENTS
Transcription
CONTENTS
Angle Grinders ACB's 534-573 307,312 373 420 35,59,200 177 542-550, 573 239-252 290 299 164-165, 168-171, 175 295 123 Batteries - Indicators/Accessories Battery Chargers Borehole Depth Tester Break-Glass Stations Busbar Trunking Systems Busbar & Supports Borehole Pumps - Controls 70,74 70-71, 77 70-75 39 365 102 146-151 50-51 40-41 Cable Accessories 317-324, 332-335 277-278, 281-282 402-404 231, 551561 10,32,211 186-187 100-104, 109 110 109, 113 111 117-122 Access Control & Security Adaptors - Domestic - Industrial Air Conditioners Air Line Controls Alarm Annunciators Alarm Systems Audible & Visual Alarms Allen Keys AMF Controls Ammeters Cable Cutters Cable Racking Cameras Capacitive Relay & Sensors Capacitors Changeover Switches Circuit Breakers - DIN - 13mm Mini Rail - MCCB Conduit & Accessories Contactors Conveyor Monitoring Switches Converters (DC to DC) Counters Crane and DC Vehicle Controls Crimping Tools Current Relays CT's Daylight Dimmers - Switches - Relays Din Rail Diodes Distribution Blocks Distribution Boards Door Chimes & Locks Drill & Taps Dust Collection Systems Earth Braids Earth Leakage Protection 314-315, 368 89-93, 116, 117 35 70 20-23 201-203 228-285, 334 9 116-167 511 14 13, 304-305, 384-391, 506, 518 139, 285 340 144-145 110, 116, 354, 357 536-539 287 35 150-154 109, 111, 114-115 Specifications are subject to change without notice in this publication. CONTENTS Electric Drills & Hammers Electronic Education Equipment - Instrument Enclosures Enclosure Fittings Enclosures - 19" - Aluminium - Dbs - Instrument - Mild Steel - Polycarbonate - Polyester - Pushbutton - Standard Plastic - Stainless - Fittings - Municipal Energy Meters & Analysers Energy Saving Controller Explosion Proof Equipment Extender Sockets Extension Cords & Reels Fans Firemans Switches - Detection Systems - Protection Fixture Accessories Fish Tape Flip Flop Relay Float Switches Flow Switches Frequency Relays Fuse Switches Fuses & Fuse Holders Gas Detectors Gas Soldering Irons Generator Controls Generators Sets Glands Gloves, Safety Grommets Hammers Hand & Hair Driers Heaters Heat Detectors Heat Shrink Heat Sinks Hole Saws Hooters Hydrosperes Hygiene Products Humidity Controllers Insect Killers & Traps Insulators Intercoms Inverters (DC to AC) Irrigation Controllers/Pool 295 276 360-363 306 342-372 346-347 131, 361 354-357, 369-372 360 349-352, 356-357 358-361 353, 360, 366 131, 348 364, 367 347-350, 366 342-345, 352, 357, 359, 365 358 173, 174-175, 180-182, 264-265 183 256-263 307 307, 312-313 410-417 239 239-240 365 325-328 316 10 32-34, 37, 43 34 9, 12 97, 99, 105 134-139 240, 257 280 184-185 299-301 317, 321, 368, 381 265 321 290 406-419 408-410, 417 240 322 31, 338 291 244,259 43 418-419, 420 193 406-407 149, 285, 322 536-572 79, 82 59 Isolators 96-105, 109, 111, 113, 117, 121 Joy Stick Controllers Junction Boxes 127 322, 364, 367 322 Joint Kits 130, 500-510 LED's 130, 337, 483, 499 Legend Plates 130 Lighting 422-553 - Emergency 398, 475-479 - Advertising/Display 451-519 - Bulkheads 399, 429, 459 - Cabinet/Display 455 - Camping & Leisure 480-482 - Daylight/Motion Switches 511 - Dc 248,454, 506 - Downlights 435, 437-441, 456, 459 - Festive/Chandeliers 468, 520530 - Fibre-Optic 527 - Flameproof/ Explosion 256, 261-262 - Flood 400-401, 429-436 - Fluorescent 399, 422-427 - Garden 397, 462-465, 471-474 - Highbay 398, 401, 428-429 - LED 248-250, 426-435, 445-452, 462, 483-490 - LED Downlights 439, 442-444, 459 - LED Street 452 - Energy Saving Lamps 502-507 - Energy Saving Fittings 502-503 - Low Voltage 494-499, 503, 508-510 - Spot/Stage 457-464 , 531-533 - Street 453 - Solar 253-254, 453, 526 - Pendant 466-467 - Track 469 - Lighting Control Gear 491-492, 498, 515-518 - Outdoor 397, 448451, 458 - Underwater 470-471 - Weatherproof 422 - Accessories 491-492, 513-518, 316 Lightning Protection 154-159 Limit Switches 204-207 Lamps © Copyright - AC/DC 2010 CONTENTS 11,15, 32-36 236-238 15, 111 Sensors - Proximity - Vision/Fibre Optic Sequence Relays Signal Converters & Isolators Signal Transmitters Smoke/Gas/Heat Detectors Socket Outlets - Weatherproof Soft Starters Solar - Panel/Home Power - Regulators/Monitors - Mounting Accessories SSR's Starters - Fluorescent - Motor MCCB's 162 76-81 287 349, 353 163-165 168-172, 183 163 180-182 204-206 130, 508-509 161 106-107, 160 267-274 341, 380-381 117-122 Over Temperature Switches Overload Relays Office / Cable Routing 160 90-91 309-311 PCB Switches Pendant Controllers Phase Angle Relays Phase Failure Relays Pivot Shut-Down Relays Pilot Lights PLC's Plug Tops -Domestic Plugs & Sockets - Appliances - Industrial 336 202 40-41 8,12,14 6,41 125 - 133 178-179 312 341 373-379, 382-383 339 156-158 173, 188-189 12, 172-174, 183, 196 267 310-311, 405 66-69 294-296 43, 198-199 43-58 40-41 87 39-40, 124-128 129 129 133 130,133 Liquid Level Controls Loud Speakers Load Controls Mains Fitters Mains Stabilisers Measuring Tapes Meter Boxes & Kiosks Meter - Analoque - Digital - Running Hour - KWH Microswitches Miniature Lamps MOV's Motor Protection Multimeters Multipole Connectors Potentiometers Power Protection Power Factor Correction Power Monitors Power Skirting - Digital - Analogue Power Supplies (AC to DC) Power Tools Pressure Switches & Sensors Pumps - Protection Relays - Starters - Controllers Pushbutton - 22mm - 30mm - Miniature - 16mm - Lights Ready Boards Rectifiers Relays Rivets & Tools Rocker Switches Rope Pull Switches Rotary Encoders Running Hour Meters Security - DVR/CCTV Selector Switches 42,110 340 5, 15, 19, 24-31, 116 289 132 207 184 180-182 534-574 563-567 165 - Photoelectric/Laser - Motion (PIR) Storage Bins Sumersible Pump Seal Relays Surge Protection Swimming Pool Boxes/ Filters Switching Accessories AUTOMATION PRODUCTS 209-213, 227 214-228 208, 304, 387, 512 230-235 10 5-6, 12 6 240 308 86-87 83-85 83, 265 82 30-31, 192 517 89, 94-95, 108 297-298 11 156-161 42 302-303, 306-307, 384-396 TV & Audio Two - Way Radios 7 292 37-39 255, 541 190-196 7, 14 143, 365 336 146 140-142 264-275 273, 276 266 5 197, 384389, 392 2-4, 12-13, 16-19, 59, 92, 196 132-338 279, 298 277-295 253-254 176 60-66, 116 310-311, 321 534-535 36 Ultrasonic Level Controls UPS's 225 78, 80-81 Variable Speed Drives Voltage Regulators Voltage Relays Voltage/Phase Indicators Voltage Protection Voltmeters 88 76-77 9, 14-16 15, 78 163-165, 168-171, 175 Water Meter Boxes Water Taps - Automatic Water Dispensers Welding Machines Weicon Adhesive/Technical Spray Wire Wireless Switches Wind Turbine Generators 358 59,419 418 296 327-331 152-153 304-305 84 Tacho Relays Taps And Drills Telemetry Systems/ GSM Telephone Equipment Temperature - Controls - Relays Terminals - Blocks - PCB - Posts - Rail Mounting Test Instruments Test Leads Test Probes HV Thermistor Relays Thermostats Timers Toggle Swtiches Tool Boxes Tools Traffic Lights Transducers Transformers Trunking LEVEL, PUMPS & TELEMETRY POWER SUPPLIES & TRANSFORMERS SOLAR & WIND GENERATORS MOTOR CONTROL CIRCUIT BREAKERS, FUSE GEAR & ISOLATORS PUSHBUTTONS & PILOT LIGHTS TERMINALS, INSULATORS & COPPER SURGE, TEMPERATURE & NOISE PROTECTION INSTRUMENTS CAPACITORS & PFC TEMPERATURE CONTROLS CRANE & VEHICLE CONTROLS LIMIT & PRESSURE SWITCHES & SENSORS ALARMS & SPEAKERS FLAMEPROOF & TELEPHONES TEST INSTRUMENTS, TOOLS & GENSETS WIRING ACCESSORIES ELECTRONICS ENCLOSURES & FITTINGS GEWISS FANS, INSECT PROTECTION & HYGIENE LIGHTING SECURITY © Copyright - AC/DC 2010 TIMERS Unequal Repeating & Delay on Two-Shot timer UP1/M UP2/M DP1* DP2* DP3 UP1/MV UP2/MV Type Code Outputs SPDT Mode of Operation Multi range timer. Time ranges: 0.15S to 10S 1S to 60S 1.5S to 100S 10S to 10M 1M to 60M 10M to 10hr Selectable by DIP switches 1, 2, 3 & 4 at rear of timer. Timing functions: Unequal repeating (off first) Unequal repeating (on first) Two-shot (off first) Two-shot (on first) Selectable by DIP switches 5 & 6 at rear of timer. UP1/MV & UP2/MV Multivolt range 24-250VAC/DC Connection Diagram AUTOMATION PRODUCTS UP1/M ONLY 2 Note: Standard stock is 11 Pin. 8 Pin available on order Supply AC Multivolt Supply DC Specification + DPDT SPDT SPDT +INST IP1* SPDT IP2* IP3 DPDT SPDT +INST Upon application of the supply voltage the delay time period begins and the power LED lights up. On the expiry of the set time the relay LED will light up and the relay will operate and will not release until the supply voltage is disconnected. Upon application of the supply voltage the relay operates, the power and relay LED lights up and the time period begins. On the expiry of the set time, the relay releases and will not operate again, until the supply is re-applied. DP3: Output relay A is instantaneous. IP3: Output relay A is instantaneous. ‘t’ x10 SUPPLY VOLTAGE DPDT Interval UP2/M ONLY – 11 Pin SPDT Equal Repeating Delay off No Power EP1* EP2* DDP1* DDP2* DDP3 SPDT DPDT SPDT DPDT Upon application of the supply voltage the relay operates and the ON time period starts. After the ON period has expired the relay releases and an equal OFF time period starts. This equal operation continues until the supply voltage is disconnected. SPDT +INST No power required delay off function. Upon application of the supply voltage the relay operates. When the supply voltage is disconnected the time period starts and at the end of the time period the relay releases, the time is reset and the relay remains released until the supply voltage is reapplied. For time ranges above 600 sec there is a built-in battery. This timer is not to be used for short pulses, as battery requires 24H to recharge. Use IAP1or 2. ‘t’ x10 SUPPLY VOLTAGE 11 Pin DPDT SUPPLY VOLTAGE 11 Pin SPDT+INST A=Instantaneous Contact SUPPLY VOLTAGE 8 Pin SPDT SUPPLY VOLTAGE 8 Pin DPDT Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV) 60 - 250VAC/DC (available only on models marked *) 12, 24, 48VDC Range accuracy: Repeatability: Scale accuracy: Reset time: Operating temperature: Power consumption AC: 1.5VA DC: 100mA @ 12VDC Contact rating SPDT: 10A 250VAC DPDT: 5A 250VAC For external potentiometer: use 1MΩ ±5% 1% ±5% 300mSec -20 to 70°C M1 See Page 11 for time ranges TIMERS Delay on Pulse Start Interval Pulse Start WM1/M PP1 DAP1 DAP2 IAP1* IAP2* 2 x SPDT 2 x SPDT SPDT SPDT SPDT DPDT SPDT DPDT Outstanding value, two timers in one! Function: When the power is applied the contact between 1 and 4 closes. The contact remains closed for an adjustable forward or ON time period. It then opens for an adjustable pause or OFF time period. After the pause delay, contacts 1 & 3 close and remain closed for a reverse or ON time (same as the forward time). After the reverse period the contact between 1 & 3 opens for the pause time. This cycle is repeated until supply is removed. DIP Switches 1 to 5: On Pause & Time Ranges: 0.15s to 10s 1.5s to 100s 1s to 1m 10s to 10m 10s to 10m 100s to 100m 1m to 1h 10m to 10h DIP switch 6: OFF. Pause period first. ON: on period first. External POT 100K Upon application of the supply voltage the OFF time starts. At the end of the OFF time the relay operates and stays in operation for the remaining on time. Thereafter it returns to the OFF position. ie. The total OFF and ON period is equal to the full time. This recycling operation will continue until the supply voltage is removed. Start switch between 5 & 7: Apply supply voltage. Upon the closure of switch 5 & 7 the timing period starts, irrespective of whether the start switch is closed or not. After the set time the relay will operate. To repeat this function supply voltage must be removed and re-applied again. Start switch between 6 & 7: Apply supply voltage. Upon closure of switch 6 & 7 nothing happens. The timing period will only start when the switch between 6 & 7 has opened, upon opening the timing period begins. After the set time the relay will operate. MFMR DP/DP DP/IP DPDT Time ranges: 0.02 to 1S 0.15 to 10S 1S to 60S 10S to 600S 1M to 60M 10M to 10H 22M to 24H 3H45M to 240H Selectable by DIP switches 1, 2 & 3 at rear of timer. Functions: Delay on (DP2) Delay on pulse start (DAP2) Interval timer (IP2) Interval timer pulse start (IAP2) Equal repeating timer (EP2) OFF first Equal repeating timer (EP2) ON first Selectable by DIP switches 4 & 5 at rear of timer. MFMRV: Multivolt supply 24-250VAC/DC External POT 100K + SUPPLY VOLTAGE DP/DP Two delay on timers sharing common power supply. Independently adjustable. DP/IP One delay on timer and interval timer sharing common power supply. Independently adjustable. – SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE Start switch between 5 & 7: Apply supply voltage. Upon the closure of switch between 5 & 7 the relay operates and the time period starts. When the set time has expired the relay releases irrespective of whether the start switch is still closed or not. Start switch between 6 & 7: Apply supply voltage. Upon closure of start switch between 6 & 7 the relay operates. The time period only starts from the break of the switch. SUPPLY VOLTAGE SUPPLY VOLTAGE SPDT DPDT AUTOMATION PRODUCTS Dual Timers MFMRV Forward Reverse Timer (Multi-range) Percentage Timer Multi-Range Multi-Function Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV) Multivolt 60-250VAC/DC (available only on models marked*). 12, 24, 48VDC Range accuracy: Repeatability: Scale accuracy: Reset time: Operating temperature: See Page 11 for time ranges ±5% 1% ±5% 300mSec -20 to 70°C Power consumption AC: 1.5VA DC: 100mA @ 12VDC Contact rating SPDT: 10A 250VAC DPDT: 5A 250VAC For External Potentiometer use 1MΩ M1 3 TIMERS Type Star-Delta Timer One-shot Timer Triac Flasher Relay Flasher Code SDP1 OSP1 OSP2 TFP1 RFP1 RFP1/A DET1 Outputs SPDT SPDT DPDT Triac output SPDT WITHOUT FAN DELAY Mode of Operation When supply voltage is applied connection between 1 and PIN 4 is made. The time period starts for Star connection. After the Star set time has elapsed connection between pin 1 & 4 is opened and stays in a neutral position for 100mS. After the 100mS pause connection is made between pin 1 & 3 for the Delta contactor. LINK:5-6: Pulse on energisation LINK 6-7: Pulse on de-energisation. When the power is applied the relay operates for 0.5 sec. When power is de-energised the relay operates for 0.5 sec. TFP1 (230VAC only) Upon applying the supply the lamp will flash with an equal on and off time until the supply is removed. This on and off time is adjustable from 0.02 - 1 sec. RFP1 On applying the supply, the lamp will flash with a fixed equal on and off time of 0.5 sec. This will continue until the supply is removed. Can be used to switch one lamp or two alternating lamp circuits. Upon application of supply voltage, cooling cycle starts, (4, 6, 8 or 12 hrs) followed by defrost cycle (1-60min). LINK 5-6: As above except defrost cycle starts first. DET1/F: Is for freezer rooms and has additional relay for fan delay (6-360 Sec). Leds “defrost on” “fan on”. Dip switch selection: TFP2 TFP2 (230VAC only) Upon applying the supply, lamp 1 will switch on then switch off and then lamp 2 will switch on. This on and off time is adjustable form 0.02 - 1 sec. Defrost Timer RFP1/A As per RFP1 except that the equal on and off time is adjustable from 0.02 to 3 sec. Repeating Pulse DET1/F RP1 WITH FAN DELAY SPDT Upon application of the supply voltage the delay period begins. On expiry of the set time, the relay pulses on for 0.5 sec and a new time period begins. This repeating pulse continues until the supply voltage is disconnected. cycle times 14 hour Triac: 1000W (4A) @ 250VAC 16 hour 18 hour 12 hour Connection Diagram OSP1 C:COOLING D:DEFROST F:FAN TEMP OVERRIDE TFP1 RFP1 & /A AUTOMATION PRODUCTS SUPPLY VOLTAGE OSP2 SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE Supply AC Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV) Supply DC 12, 24, 48VDC Specification 4 TEMP OVERRIDE TFP2 Power consumption: Output rating: SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC Triac: 1000W (4A) @ 250VAC M1 AC 1.5VA DC 100mA @ 12VDC PROCESS CONTROLS Type Alarm Relay 3I/P 3O/P Thermistor Relay Single & Dual Alarm Relay Differential Relay Signal Converter Code AL3 TH1 SAR1 DAR2 DIR Outputs SIC1† SIC1† 4 x SPST SPDT SPDT DPDT Mode of Operation On closing of any input contact, the corresponding output relay and hooter will energise. By using a common flasher connect to PIN 11 lamp 1 will flash. By pressing the accept button the lamp will steady and remain on until the fault is removed, and the hooter will stop. More alarms can be added by merely commoning up more modules with no restriction. Pins to be common when expanding; 11,10, 9, 7 and common of hooter. Failsafe design. SAR1: Single trip point DAR2: Two trip point (2 relay outputs independently adjustable) Latch facility Link PINS 7-9. Relay remains de-energised after tripping. To reset, break supply voltage or operate N/C external reset device connected to PINS 7-9. 0-10V This module provides a relay output with high and low set points from an analogue instrument signal. INPUT LINK 6 & 7 0 -20 mA NO LINK 6 & 7 4 - 20 mA SUPPLY VOLTAGE Lamp test Pin 7 Alarm accept Pin 9 Hooter Pin 8 To be utilised with relay flasher RFP1 to Pin 11 4-20mA The Signal Converter modules convert various input signals to a 4-20mA or 0-10V DC signal. They are intended for use with all PLC and other instrumentation The relay is normally The output relay will systems. de-energised and will energise on the high set †Input selection energise when the input point and de-energise on A: 0-5 Amps AC/DC signal reaches the set the low setpoint offering B: 0-1 Amps AC/DC level, set by a a wide adjustable R: Ohms potentiometer. The relay differential. V: Voltage range AC/DC will de-energise when the Calibration: For field input signal drops below When more than one unit calibration, energise module the set level by 3% is used in series and the and set input to maximum. supply is DC, an isolator Adjust SPAN until outputis The second alarm relay must be used for each 20mA/10V. Set input to operates the same but unit: minimumrequirement and set at a different trip ISO-12VDC adjust ZERO until output is level. ISO-24VDC 4mA/0V. Calibration is complete. Red LED: Power on. Connection Diagram Specification SPDT SIC2† SIC2† INPUT LINK 6 & 7 0 - 5VDC NO LINK 6 & 7 1 - 5VDC SUPPLY VOLTAGE Tripping resistance 1.2kV Input signal: No. of thermistors to be 4 - 20mA conntected in series not 0 - 20mA to exceed 1kV or 0 - 5VDC 1 - 5VDC SUPPLY VOLTAGE Input signal: 4 - 20mA 0 - 20mA DIR or 0 - 5VDC DIRV 1 - 5VDC } } SUPPLY VOLTAGE Inputs: SIC*A: 0-5 Amps, AC/DC SIC*B: 0-1 Amps, AC/DC SIC*R: 1-20kV SIC*V 10V: 0-10V, AC/DC SIC*V 150V: 0-150V, AC/DC SIC*V 300V: 0-300V, AC/DC SIC*V 600V: 0-600V, AC/DC * 1: for 4-20mA. 2: 0-10V output Power consumption DC: 600mA @12VDC AC ± 1.5VA Supply AC Not Available Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV) Supply DC 12, 24VDC Contact rating AUTOMATION PRODUCTS The relay is normally energised, when one of the thermistors reaches tripping temperature the relay de-energises. The relay will energise when the temperature drops to below trip level. DIRV 12, 24, 48VDC SPDT: 10A @ 250VAC M1 DPDT: 5A @ 250VAC 5 PROCESS CONTROLS Type Namur Sensor Relay Pivot Shut Down Relay Code NS1 VCT1 Outputs SPDT SPDT Mode of Operation Failsafe design. Failsafe design. The Namur sensor relay converts the changing current of an Inductive or Capacitive Namur sensor into a relay switching. The sensor can be connected between 5 & 6 to energise the relay when the sensor is activated, or between 6 & 7 to energise the relay when the sensor is deactivated. See page 210 for Namur sensors. Signal Isolator (Transducer) Input Output 4-20mA 4-20mA For use with centre pivot irrigation systems to prevent overwatering of the field. On application of voltage, the output relay energises for the adjustable start up delay period. Once running, if the pivot arm motors do not draw a minimum adjustable current within an adjustable time (usually 3 minutes for 20% watering), the output contact de-energises, switching off the Pump Start circuit. 0-10V Code SI-1A SI-1V 0-10V 4-20mA 0-10V 4-20mA 10-0V SI-1A/V SI-1AV REV All outputs are galvanically isolated from inputs. Output: 4-20mA into 0-600 ohms load. Isolation between IP/OP and Mains = 600V AUTOMATION PRODUCTS Supply AC Supply DC Contact rating 6 AC: ±1.5VA – SUPPLY VOLTAGE SUPPLY VOLTAGE Supply Voltage A = AC 85 to 265V DC 100 to 330V B = DC 20-60V Speed (Frequency Transmitter) For use with DIN type CT-5 current transformer (see page 128) (Input 0-4V) DC: 100mA @ 12VDC 1.5VA – SPDT: 10A @ 250VAC P: PT100 F: 0 to 100°C D: -50 to 200°C G: 0 to 200°C DC Output Multi-Range (Selectable by DIP Switch) V2: 0 – 5V A2: 0 – 10mA V3: 1 – 5V A3: 0 – 20mA V4: 0 – 10V A4: 4 – 20mA A1: 0 – 1mA Galvanic isolation with internal transformer 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV) – V2: 0 – 5V V3: 1 – 5V V4: 0 – 10V A1: 0 – 1mA A2: 0 – 10mA A3: 0 – 20mA A4: 4 – 20mA RTD (PT100) Transmitter (Isolator) A S4X-RR-P -A4- B + Power consumption V1: 0 – 50mV V2: 0 – 5V V3: 1 – 5V V4: 0 – 10V A1: 0 – 1mA A3: 0 – 20mA A4: 4 – 20mA Code: S4X-PT-A – Sensor current: 8mA Open voltage: 8.5V DC Input Range DC Output Range Supply Voltage: AC 85 – 265V/DC 100 – 330V Input Potentiometer: (3 Wire) 1: Total resistance 100V – 10KV + Specification Code: S4X-DT-* *Add Supply Voltage: A = 85 to 265VAC/100 to 330 VDC B = 20 to 60VDC Multi-range Input and Output Selectable by DIP switches on side of unit. Potentiometer Transmitter Connection Diagram SUPPLY VOLTAGE Signal Isolator Transmitter – DPDT: 5A @ 250VAC M1 S4X-RT-B-2-M-A 0-100Hz Input S4X-RT-E-2-M-A 0-1KHz Input S4X-RT-F-2-M-A 0-2KHz Input S4X-RT-H-2-M-A 0-10KHz Input Supply Volts: 85 to 265VAC Output Programmable: 4-20mA, 0-10V Specification: Accuracy: ± 0.1% RO. Isolation: Input/Output/Power Insulation Resistance: ≥ 100MV, DC 500V Impulse Withstand Test: IEC 1000-4-5, class 4 PROCESS CONTROLS Over/Under Speed & Tacho Relay Three Start Attempt Relay Coincidence Relay TSAP1 CS1 Start: SPDT Alarm: SPDT SPDT Failsafe design. External contacts A and B typically are pushbuttons mounted 1m + apart on a press or guillotine. The operator must press both buttons, keeping his hands safely away, before the machine operates. Apply the supply voltage. The contacts A & B must be actuated within 0.5s in order to make the relay operate. If one of the contacts is interrupted the relay will immediately release. Upon application of the supply voltage, the ‘start’ relay operates for a set ‘on’ duration followed by a set ‘dwell’ cycle. After the relay has operated for the no. of starts as per the dip switches and the supply voltage is still present, the ‘alarm’ relay will operate and this condition will prevail until the supply voltage is removed. Dip switch setting: 3-6 starts Start time: 0.5-30sec adjustable. TM1 TM4 TM4/R SPDT Failsafe design. Ideal for use in machine safety guard systems. Failsafe design. The Tacho relay connects to a PNP,NPN or Namur inductive or capacitive sensor. Under Speed: Link 5 & 11. The relay energises if input speed drops below the set limit. Over Speed: No link 5 & 11. The relay energises when the speed exceeds the set limit. DIP SW: SW1 ON: NPN SW1 OFF: PNP Output TM4: SW2 ON: 4-20mA SW2 OFF: 0-20mA Ranges: Posn RPM 1 2-20 2 5-50 3 10-100 4 20-200 5 50-500 Posn RPM 6 100-1k 7 200-2k 8 500-5k 9 1k-10k 10 2k-20k Temperature Relay for T/C: J & K TRJ2 TRK2 TRJ4 TRK4 SPD SPDT 0 to 400°C 0 to 200°C Failsafe design. TRJ2 & TRJ4 for J type thermocouple TRK2 & TRK4 for K type thermocouple The temperature relay connects to a temperature sensor. The relay energises when the temperature exceeds the set limit. The relay de-energises when the temperature drops below the set limit. Remote control available on request. Temperature Relay for T/C: PT100 SPDT -20 to +80°C TR1 SPDT 0 to 100°C SPDT +50 to 150°C SPDT +50 to 200°C TR2 TR3 TR4 Failsafe design. Link 8 & 9: (under temp). The temperature relay connects to a temperature sensor PT100. The relay energises when the temperature exceeds the set limit. The relay de-energises when the temperature drops below the set limit. NO Link 8 & 9: (over temp). The relay energises on application of power and will deenergise when the temp. exceeds the set value. AC Supply only PNP OR NPN Supply Voltage: 9-30VDC standard. Other Voltages available SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE TM1 - 1mA Output TM4 - 4-20mA Output TM5 - 0-20mA Output TM4/R - Remote 1MV pot Hysteresis: 3% fixed Namur connect 6-7 NPN/PNP connect 5-6-7 AC: ±1.5VA Control: On/Off Proportional on request Latch: Pin 8 & 9 Hysteresis 3% fixed Faulty thermocouple Indication: Flashing LED SUPPLY VOLTAGE AUTOMATION PRODUCTS SUPPLY VOLTAGE Overtemp: No link between PINS 8 & 9 Undertemp: Link 8 & 9 Hysteresis: 0 - 100% DC: 100mA @ 12VDC Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV) SPDT: 10A @ 250VAC M1 DPDT: 5A @ 250VAC 7 POWER MONITORS Type Phase Failure & Sequence Relay Phase Failure & Sequence Relay Supply Protection Relay Over & Under Voltage Three Phase Code SMP1 1000 SMP1 SMP1/N SMP2 SMP2/N SPR3 TWCP1 Outputs SPDT SPDT DPDT Mode of Operation Failsafe design. Failsafe design. This three phase (3 wire) unit monitors the supply voltage for all systems between 525 and 1000V. The output relay energises if the phases are all present and in the correct sequence. The relay de-energises when any phase is lost or the phase sequence is incorrect. The unit is housed in a DIN rail mounting housing suitable for 1000V connections. This three phase (3 or 4 wire) unit monitors the supply voltages. The output relay energises if the phases are all present, in the correct sequence and each voltage is within 5-15% range (adjustable) of each other. The relay de-energises on: a. A phase voltage imbalance exceeding the adj limit (5-15%). b. Total failure of one or more phases. c. Incorrect phase sequence. d. Supply exceeds 15% under/over nominal voltage (Link 2-10 options). Built-in optional facilities (SMP1 & SMP1/N only) 1. 180 sec fault restart delay. 2. 15% fixed over/under voltage. These facilities can be utilised by connecting external links as per the diagram below. SPR3/N SPDT SPDT Failsafe design. SPR3: 3 Phase (3 wires) SPR3/N: 3 Phase + N (4 wires) This three phase (3 or 4 wire) unit monitors the supply voltage and combines the protection features of the SMP1 and TWCP1. The output relay energises if the phases are all present, in the correct sequence and each voltage is to within the adjustable over and undervoltage limits. The relay de-energises on: a. Phase voltage imbalance exceeding the 10% (preset) b. Total failure of one or more phases. c. Incorrect phase sequence. d. Any phase falling outside the set voltage range. Built-in optional facilities: 1. External latch N/C 2. 10 sec start up delay 3. 180 sec fault restart delay These facilities can be utilised by connecting external links as per the diagram below. TWCP1/N Failsafe design. TWCP1: 3 Phase (3 wires) TWCP1/N: 3 Phase + N (4 wires) This three phase (3 or 4 wire) window voltage comparator monitors the supply voltage. The output relay energises if the voltage level is within the adjustable over and undervoltage limits and de-energises when the voltage is outside this range. Built-in optional facilities: 1. External latch 2. 10 sec start up delay 3. 180 sec fault restart delay These facilities can be utilised by connecting external links as per the diagram below. Connection Diagram AUTOMATION PRODUCTS SMP1 ONLY Specification Hystersis Contact rating 8 N: FOR SPR3/N N: FOR TWCP1/N For any 3 phase system with a SMP1 & SMP2 – 3 Phase nominal voltage from 525 to 1000V. SMP1/N & SMP2/N – 3Phase + N Phase imbalance: 5-15% ADJ. LED: SMP1 & SMP1/N only Supply healthy – Green Link 8 & 9 180sec fault restart delay DIN mounting housing Link 2 & 10 for SMP1 only 15% fixed over/under voltage protection. LED: Supply healthy – Green Available for 110, 230, 400V and 525V systems Link 8 & 9 External latch Link 9 & 10 10 sec start up delay Link 9 & 11 180 sec fault restart delay. Phase imbalance: 10% fixed Overvolts 0 - 20% ADJ. Undervolts 0 - 20% ADJ. LEDs: Over/Undervolt – Red Phase rotation – Red x2 Supply healthy – Green Link 8 & 9 Ext. Latch N/C Link 9 & 10 10 sec start up delay Link 9 & 11 180 sec fault restart delay Overvolts 5 - 20% ADJ. Undervolts 5 to 20% ADJ LEDs: Over voltage – Red Undervoltage – Red Supply healthy – Green 2% Fixed 2% Fixed 2% Fixed N: FOR SMP1/N ONLY 2% Fixed SPDT: 10A @ 250VAC M1 DPDT: 5A @ 250VAC POWER MONITORS Over Current Monitor Under Current Monitor Over & Under Current Monitor Over & Under Frequency Monitor WCPT1 VCP1 VCP1/M OCP1 OCP1/D UCP1 UCP1/D CWP1 FR1 SPDT SPDT SPDT SPDT SPDT SPDT Failsafe design. Failsafe design. This new single phase window voltage comparator replaces WCP1 and monitors the supply voltage. The output relay energises if the voltage level is within the adjustable over and undervoltage limits and de-energises when the voltage is outside this range. Built-in optional facilities: 1. External latch 2. 10 sec start up delay 3. 180 sec fault restart delay These facilities can be utilised by connecting external links as per the diagram below. SUPPLY VOLTAGE The output relay is energised when the voltage peak (peak voltage on AC) overshoots the level selected on the front face potentiometer. It de-energises when voltage falls below the normal voltage Ue by 5-50% or when supply breaks. The hysteresis is adjustable and its selection does not change the chosen voltage level. SUPPLY VOLTAGE SPDT SPDT SPDT CWP1 - 1A/5A AC/DC The relay senses the OCP1 - 1A/5A AC/DC UCP1 - 1A/5A AC/DC OCP1/D - 60mV/150mV UCP1/D - 60mV/150mV input current and the relay will energise, if the AC/DC AC/DC current is within the set overcurrent and Trip Point - The relay Trip Point - The relay undercurrent. de-energises when the de-energises when the The relay will input current rises above input current drops de-energise if the the set point and below the set point and current rises above the energises when the energises when the overcurrent setpoint or input current falls a input current rises a drops below the under certain percentage certain percentage current setpoint. (hysteresis) below the (hysteresis) above the set point. set point. LEDs: Hysteresis - The Hysteresis - The difference between the difference between the Over current – Red Under current – Red trip level and the set set trip level and the level. recovery level. Supply on – Green Failsafe design. Failsafe design. SUPPLY VOLTAGE SUPPLY VOLTAGE Link 8 & 9 External latch N/C Link 8 & 7 10 sec start up delay. Link 8 & 6 180 sec fault restart delay. Overvolts 5 - 30% ADJ. Undervolts 5 to 30% ADJ. LEDs: Over voltage – Red Under voltage – Red Supply healthy – Green VCP1/M: Multi voltage inputs: UCP1 OCP1 CWP1 Connect: Input: 5-8 0 -10VAC (RMS) DC AC: 0 - 1A 6-8 0.4 -40VAC (RMS) DC Pins 5 +7 7-8 4 -400VAC (RMS) DC 0 - 5A 11-8 6 -600VAC (RMS) DC Pins 6 +7 Startup delay: 10 seconds For external pot use 10kV UCP1/D OCP1/D 2% Fixed 5 - 50% Adjustable 2% Fixed DC: 0 - 150MV Pins 5 +7 0 - 60MV Pins 6 +7 5 - 50% Adjustable SPDT: 10A @ 250VAC M1 Failsafe design. The unit senses the supply frequency and the relay will energise if the frequency is within the set over frequency limits. The relay will de-energise if the frequency rises above the over frequency setpoint or drops below the under frequency setpoint. Link 6 & 5: Under Hz Link 6 & 7: Over Hz SUPPLY VOLTAGE AUTOMATION PRODUCTS Over & Under Voltage Single Phase Voltage Monitor Response delay: 1 sec Over: 52 - 58Hz adjustable Under: 48 - 42Hz adjustable LEDs: Over frequency – Red Under frequency – Red Supply on – Green 2% Fixed DPDT: 5A @ 250VAC 9 LEVEL AND PUMP CONTROL Flip-Flop Relay Pulse Start Flip-Flop Mains Controlled Pump Sequence Control Relay FNCP1 FFCP1 FFP1 FFP2 FFP3 FFP4 SPDT SPDT SPDT SPDT DPDT 3 Pumps 4 Pumps Failsafe design. For alternating pumps FNCP1 (No memory) Closing of contact across 5 & 7 the relay will energise. Closure of contact again, the relay will de-energise. When the relay is in the ON position and the supply voltage is removed, the relay will reset. (No memory). Type Capacitive Level Relay Code CLR1 Outputs Mode of Operation CLR2 CLR1 Using NPN Probe Filling: The relay energises when the level drops below the lower level sensor and de-energises when it reaches the high level sensor. Emptying: As above with opposite function. Link 7 & 9. Using PNP Probe Functions reverse. NPN Sensor: SD10G-ARN1 Page 32 NPN Sensor: CS-09 Page 211 CLR2 2 Wire Probe connection: Probe 1 5(+) 6(–) Probe 2 7(+) 6(–) Probes VR1A or VR1B Pg. 32. Single Probe connection: Probe 5(+) 7(–) FFCP1 (With memory) Closure of contact across 5 & 7, the relay will energise. On closure of the contact again the relay will de-energise. The relay remains in this position even on removal of supply. (with memory). Mains controlled: Change on removal of supply. The relay is initially in any state, on or off, apply supply voltage. The relay keeps its state. Remove the supply voltage. The relay will now change state and will keep its state without the supply. Apply and remove the supply again for the next change in state. Mains controlled: Change on application of supply. Link pins 5 and 7 (Link A). Apply supply voltage. The relay changes state. Remove supply. The relay keeps its state. Pulse controlled. Link pins 6 and 7 (Link B). The relay is initially in any state, apply supply voltage. The relay keeps its state. When the contact between pins 5 and 7 closes, the relay will change state. Remove the supply voltage. The relay will keep its state without the supply. Minimum time supply connected for relay to react: 1 second. NB: Voltage Free Inputs Connection Diagram FFP3 AUTOMATION PRODUCTS CLR1 SUPPLY VOLTAGE Response time: 500mS Sensor connections NPN: Pin 5 (P) H Level - Black Pin 6 (P) Common - Brown Pin 7 (N) Common Blue Pin 8 (P) L Level - Black Use VP02E or CS09 Power consumption SUPPLY VOLTAGE SUPPLY VOLTAGE FFCP1: Not available in 12VDC AC: ± 1.5VA SUPPLY VOLTAGE FFP4 Response time: 0.2S Not available in 12VDC DC: 100mA @ 12VDC Supply AC Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV) Supply DC 12, 24, 48VDC Contact rating 10 Float or Pressure switches are connected to pins 1, 11, 6 and common on 5. When the first switch closes, relay 1 energises. When the second and third switches close, the second and third relays energise. There will always be as many relays energised as there are input switches closed. When 1, 2 or 3 pressure switches open, 1, 2 or 3 relays will de-energise. The positions of the pressure switches do not matter, only how many are switched on at a time. When all switches open and no relays are energised, and a switch closes again, then relay 2 will be the primary relay, that is the first relay to energise, then relay 3, and then relay 4 or 1. Every time the first switch closes, the next relay will be the first to energise. The supply must be connected for the relays to energise. The currently selected primary relay is stored in nonvolatile memory. The relay will remember which relay to energise first, even if the supply is disconnected. SPDT: 10A @ 250VAC M1 DPDT: 5A @ 250VAC See also Phase Angle relays Page 41 LEVEL AND PUMP CONTROL ACCESSORIES For Plug-In Modules BC B2 2-Level Liquid Level Relay 3-Level Liquid Level Relay Submersible Pump Seal Monitor TE101 TE201 DLR SPSM1 SPDT DPDT DLRA DPST Failsafe design. Filling: Link 7 & 8. The relay energises when the level drops below the low level probe and deenergises when it reaches the high level probe. Top and bottom probes are interchangeable. Emptying: No link between 7 & 8. The relay energises when the level reaches the high probe and deenergises when it drops below the low probe. • For single level sensing connect pins 5 & 6 (Probes 5 & 7). • 1s response time to limit effect of water ripple. Longer times manufactured to order. TE101B: Dual voltage 230/400V For Probes, see Pg. 32 Accessories SPDT Failsafe design. Failsafe design. DLR For alternating pumps There are two relay outputs with flip-flop action each cycle for alternating duty of pumps. Relay is connected to four probes . Filling: Link 7 & 8. Pump 1 starts when the level drops below the start level probe. Pump 2 will start if the level drops to the second probe. Both pumps run until tank is full. The next cycle pump 2 first then pump 1. Emptying: No link between 7 & 8. Function as above but reversed. DLRA For one pump & alarm Output relay energises and de-energises between 2 levels like TE101. When extreme level is reached, the alarm output energises (2nd Relay). Alarm can be used for high or low function. For Probes, see Pg. 32 RC For protection of submersible motors against damage caused by the ingress of water. Terminals 5 & 7 connect to the monitoring terminals on the submersible motor. The output relay energises upon application of power. The relay will de-energise if probe current is more than 20µA or if probe resistance is less than 1Mohm. The relay will energise if probe current is less than 15µA or if probe resistance is more than 1,4Mohm. Timer box - Black Retaining clip 11 Pin base cover Bezel for panel mount Remote pot. 1mV Remote pot. 10kV Code A1024BK RC BC B2 POT 1MEG POT 10K External dimensions (mm) A1024BK SUPPLY VOLTAGE SUPPLY VOLTAGE SUPPLY VOLTAGE Max Voltage on probe = 24VDC Max Current through probe = 120µA = 0.12mA. LEDs: Power on – Red Seal healthy – Green Level sensor: Probe volts 5 VAC @ 1.5mA Adjustable sensitivity: 0 - 50 kV AC: ± 1.5VA DC: 100mA @ 12VDC Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV) 12, 24, 48VDC SPDT: 10A @ 250VAC DPDT: 5A @ 250VAC M1 0.02 - 1 sec 0.05 - 3 sec 0.20 - 10 sec 0.50 - 30 sec 1 - 60 sec 3 - 180 sec 6 - 360 sec 10 - 600 sec 0.25 - 15 min 0.05 - 30 min 1 - 60 min 2 - 120 min 3 - 180 min 0.08 - 5 hours 0.1 - 6 hours 0.13 - 8 hours 0.26 - 16 hours 0.4 - 24 hours All timers, 11 Pin and 8 Pin, above 360 seconds: prices differ. 8-Pin plug in timers The following timers are available in 8 Pin: DP1, DP2, DP3, IP2, IP3, EP1, EP2, UP1, UP2, DDP1, DDP2, DDP3, DAP1, IAP1, SDP1, PP1, TSP1 and OSP1. AUTOMATION PRODUCTS Standard time ranges 11 DIGITAL POWER MONITORS Operation Code Output Mounting Specification Digital 3-Phase Voltage Relay 0-999 AEVR-YH 400VAC AEVR-Y4 (400VAC+N) Digital Frequency Relay 0-99.9 AEFR-Y 8 PIN plug-in/Flush mount 8 PIN plug-in/Flush mount 11 PIN plug-in • Over and Under Voltage detection which is adjustable. • Over and Under Voltage Trip Delay adjustable 0.1-10 sec. • Phase Loss Detection. • Phase Sequence detection. • Phase Imbalance. • Manual/Auto Reset with 1-5 sec trip delay. • Cutout Size: 62 x 50mm. • Over Frequency: 50Hz-99Hz. • Under Frequency: 10Hz-60Hz. • Trip Delay: 1-10sec. • Manual/Auto Reset with 1-5 sec trip delay. • Cutout Size: 62 x 50mm. • Delay on Operation. • Supply Voltage: 230VAC, 110VAC, 24VAC/DC, 12VAC/DC. • Accuracy: < 0.3%. • Power consumption: < 3W. • Master reset on closure of contact on Pins 5 & 6. • Pause on closure of contact on Pins 5 & 6, timer will continue on opening of contact. SUPPLY VOLTAGE Range 9999 (S) (H) (M), 99M 59S, 99H 59S 99 Days 23H Supply: AC: 110 and 230VAC Code NT-411 Signal Converter/ Isolator ETK-MT3 Programmable Analogue + Alarm (open collector) min/max DIN Mounting Microprocessor based intelligent module for temperature sensor and other analog signal inputs. ETK-MT offers: • conversion capability from low level input signal into high level standard output • linearization and/or modification of the measured value • galvanic isolation between input and output • min and/or max alarm threshold with common output. Specifications: SUPPLY VOLTAGE SUPPLY VOLTAGE 85-264VAC DIN Timers Description Time Range Code Delay on Timer 0.1-10secs NTE8-10B 10-120secs Contacts: 5A @ 250VAC Operation: 4 digit setting & display timer with multi output mode: delay auto reset. Auto/man reset and self hold, Instant reset. Remote start/stop and reset. Mounting: 72 x 72mm SIGNAL CONVERTER/ ISOLATOR (14-36VDC) Relay 5A @ 250VAC Digital Timer with Display AUTOMATION PRODUCTS AS14S Relay 5A @ 250VAC AEVR-YH no neutral AEVR-Y4 with neutral 12 Digital Delay On Timer 0.025 to 99H99M Relay 5A @ 250VAC Connection Diagram Diagram: DIGITAL MULTIRANGE TIMER 0.5-8mins (480secs) Pulse Start Interval Timer 0.5-8mins (480secs) Contact: N/O 5 Amp @ 230VAC Supply: 230VAC Connection Diagram DPM NTE8-120B NTE8-480B NTE8-480A • Input Programme: TC/RTD (3 & 4 Wires) • Range & Minimum Span (Programmable) • Digital Input Filter (high noise attenuation): 4 levels configurable • Input Impedance: >1 mOhm (in V) >10 mOhm (in mV) >10 ohm (in mA) • Open Input Detection (thermocouple): out > max +5% • Sensor Current (RTD, resistance, potentiometer): 200µA ( 3 Wires) 400µA (4 Wires) • Sensor Wire Resistance (RTD, resistance, potentiometer): <500 Ohm • ETK-MT3 Programmable; Output 0-20/4-20mA 0-10/ -5+5VDC • Output Resolution: 4000 points • Alarms: min and/or max (configurable by PC) • Alarm Output: Open collector (isolated 2500Vrms) • Sampling Time: 35msec • Response Time: 200msec Programming Software ETK-MT Code Software package for the configuration of = input, working range, output type, digital input filter and alarm thresholds Timers MINI DIN TIMERS, STAIRCASE TIMERS & DIMMERS Operating temp: -20 to 60°C Type PCM-04* PCM-10* Multi-functional Timer Multi-functional Timer Output Relay 1 C/O - 16A 1 C/O - 16A Function This multi-function timer has 10 This multi-function timer has 10 independant operating modes. independant operating modes. Wide time adjustment 0.1sec to Wide time adjustment 10 days. 0.1sec to 100 days. • Delay ON operate. • Unequal repeating OFF first. • Delay OFF (Interval). • Unequal repeating ON first. • Repeating starting with OFF. • Two shot timer ON first. • Repeating starting with ON • Two shot timer OFF first. • Delay pulse on 0.5 secs • Permanent switch ON mode. • Interval pulse start on rising edge. • Permanent switch OFF • Interval pulse start on mode. falling edge. •Switch ON pulse start T1 • Bistable relay with time delay and pulse OFF T2 delay. • Switch ON/OFF delay. •Pulse start interval T1, • Interval pulse start with second pulse T2. •ON pulse OFF starts T1 & T2 retriggering. Supply *230VAC, * Add voltage to code *24V(AC/DC) Operating temp: -20 to 45°C Code PCM-03/U PCM-03* (12-240VAC/DC) Type Time Output relay Function Cycling Timer 0.1 Sec - 10 Days 1 C/O - 16A The one mode time relay has an equal ON/ OFF repeating time delay starting with OFF. Wide time adjustment range: 0.1sec to 10 days Power & Relay ON LED. Accuracy 0.2%. Supply *230VAC * Add voltage to code *24V (AC/DC) *230VAC, *24V(AC/DC) IP65 PCM-01* PCM-01/U (12-240VAC/DC) PCM-02* PCM-02/U (12-240VAC/DC Delay ON Delay OFF (Internal) 1 C/O - 16A The one mode time relay has a delayed switch on function. The relay is released by power to the system. Wide time adjustment range: 0.1sec to 10 days. Power & Relay ON LED. Accuracy 0.2%. 1 C/O - 16A Upon application of the supply voltage the relay operates and the time starts. On the expiry of the set time the relay releases. The relay is reset by Power OFF to the relay. Wide time adjustment range: 0.1sec to 10 days. Power & Relay ON LED. Accuracy 0.2%. PCM-06/U Delay OFF (no power) or Delay ON 2 C/O 8A Mode A: On application of the supply voltage the relay operates when the supply volage is disconnected the timer period starts. After the adjusted time is over the relay releases. Time ADJ 0.15s-10m for delay OFF. Time ADJ 0.1s-1h for delay ON Power & Relay on LED Accuracy 0.2% Mode B: Delay ON operation *230VAC, *24V(AC/DC) *230VAC, *24V(AC/DC) 12-240VAC/ DC IP40 ASH-01/U ASM-01/U DIP-02 DIM-20 Staircase Timer 10 Sec - 10 Min 1NO - 16A Staircase, corridor time delay device. Operating time adjustable from 10 secs to 10mins by means of potentiometer. 2 Way switching. 3-wire or 4-wire installation. Size: 69 x 56 x 27mm Staircase Timer 10 Sec - 10 Min 1NO - 16A Similar to ASH-01 but in DIN Power: Red LED indication Time adjustment: 10 secs to 10mins 1 Module width Light Dimmer – – Light intensity memory. Compact Design. LED indicator. 3 Wire design. Can fit into 4x2 flush box. Triac Output. Wiring: Black: Live Brown: Load Red: Switch Size: 50 x 50 x 26mm Max load: 350VA Resistive load Min load: 30VA Light Dimmer – – Intelligent dimmer lighting control unit for resistive, inductive loads or electronic ballasts and dimmable energy saving flourescent lamps. DIN Rail Mount. LED indicates load on. Lighting level memory when power OFF. Energy saving in Stand-by mode. Max load: 500VA Resistive or inductive load. Min:30VA 12-240VAC/ DC 12-240VAC/ DC 230VAC 230VAC 50/60Hz DPM AUTOMATION PRODUCTS Code 13 PHASE FAILURE, VOLTAGE, DAYLIGHT & TEMPERATURE RELAYS Operating temp: -20 to 60°C IP65 Code CKM-01 Type 3 Phase Failure & Sequence Output Relay 1 C/O - 10A Phase sequence, total Function and partial loss monitoring device. Monitors wrong phase sequence, or loss of one phase. < 180V Switch on Delay: 5-10 Secs Switch off Delay: 1-5 Secs Voltage Threshold ADJ 170 - 200V Hysteresis ±10V Correct / wrong phase seq. LED Supply CKH-01 PNM-10 3 Phase Failure & Sequence 1 C/O - 10A Phase sequence, total and partial loss monitoring device. Monitors wrong phase sequence, or loss of one phase. < 180V Switch on Delay: 5-10 Secs Switch off Delay: 1-5 Secs Voltage Threshold 185V Hysteresis ±10V Correct / wrong phase seq. LED Powered from own supply Powered from own supply 400V + N 400V + N 1 phase Over/ Under Voltage Relay 1 C/O - 10A Over/ under Voltage monitoring relay. Single phase monitoring Minimum and Maximum voltage adjustment Min value: 170V - 225V Max value: 235V - 290V Switch off time delay adjustment: 0 to 12Secs 230VAC 50/60Hz Operating temp: IP65 -20 to 45°C AUTOMATION PRODUCTS Code 14 WZH-01 WZM-01 Daylight Relay Type 230VAC 50/60Hz Supply Output relay 1NO - 16A Used to control lighting Function depending on lux density levels. The unit is resistant to momentary changes in lighting levels Lux adj 0.1 to 200Lx Photocell included Size: 69 x 56 x 27mm Switching delay: 30S Hysteresis: +5-60Lux Daylight Relay 230VAC 50/60Hz 1 C/O - 16A Used to control lighting depending on lux density levels. The unit is resistant to momentary changes in lighting levels Requires Light Sensor Lux adj 0.1 to 200Lx Sensor cable max length 50m Switching delay: 30S Hysteresis: +5-60Lux Daylight Sensor Daylight Sensor Code SOH-* The SOH-0* is designed for operation with the Daylight Switches. *01: 1m connecting cable. *03: 3m connecting cable *05: 5m connecting cable Code IP54 DPM PNM-32 3 phase Over/ Under Voltage Relay 1 C/O - 16A Over/ under Voltage monitoring relay. Three phase monitoring Minimum and Maximum voltage adjustment Min value: 170V - 225V Max value: 235V - 290V Switch off delay 5 secs Phase seq. LED Voltage asymmetry LED L1, L2, L3 phase LED Relay ON LED Powered from own supply 400V + N Digital Display Over/ Under Voltage Phase Failure 1 C/O 16A Protection of 3 phase systems against: • Phase sequence • Phase failure • Over/ Under volts adjustable 170-225V 235-290V phase to neutral volts • Features: - Delay ON time setting 2-15s - Delay OFF time setting 2-15s - Voltage histeresis 1-4V - Voltage asymmetry level setting 10-60V Powered from own supply 400V + N RTM-01 Temperature Regulator 230VAC, 50/60Hz 1 C/O - 16A DIN mounted temperature controller. -5°C to 40°C. Underfloor heating etc. For use with standard NTC sensor, from 3m to 50m (See below) RTM-20 Code IP67 RTM-30 Digital Temp Regulator 230VAC 50/60Hz 1C/O - 16A RTM-20: -5°C to 60°C. RTM-30: -10˚C to 90˚C Underfloor heating etc. LCD display No freeze, comfort, economy modes Indication of temp value and adjustable temp required. 24hr 7day ON/ OFF settings RTM-20 Heating only RTM-30 Heating & cooling For use with standard NTC sensor, from 3m to 50m. (See below) Temperature Sensor SOS-01 The SOS-01 is a standalone sensor. To be used with WZM-01. The length of the interconnecting cable may not exceed 50m. PNM-31 NTC-03 For use with the RTM-01 and RTM-20 temperature regulator. Cable length: 3m (can be extended up to 50m) Temperature -5°C to 60°C Code Type Output Relay Function Supply 3 phase LDM-10 LDM-30 Voltage Indicator – – The module is used for graphical presentation of either one phase or three phase voltage supply system levels. The voltage value is shown by lines of LEDs. Range from 195V to 254VAC PH/N LDM-30 Loss of L1 will cause total switch off Input voltage tolerance: -15-10% LDM-10: 1 phase 230VAC monitoring LDM-30: 3 phase 400 VAC + N monitoring PMH-01 PMM-01 Over Current Limiter 1 NO - 16A AC1 4kW Used to monitor and switch off supply when the Load power value has been exceeded, Adj: 0.2 - 2kW. Unit measures current every 40 secs. 230VAC 50/60Hz Over Current Limiter 1 NO - 16A AC1 4kW Used to monitor and switch off supply when the Load power value has been exceeded, Adj: 0.2 - 2kW. Unit measures current every 40 secs. 230VAC 50/60Hz PPM-05/5 (0.5-5A) PPM-05/16 (1.6-16A) Load Control Relay 1 C/O - 16A AC1 4kW When the adjusted current value is exceeded (term 1, 2) the monitor switches off the non-priority load, with the adjusted time delay. Current values and time delay can be adjusted. 230VAC 50/60Hz On application of the supply voltage, the relay will energise, and the geyser will switch on. Current adjustment can be set so that if one stove plate is on, the geyser will remain on. When the second stove plate is switched on the geyser will be switched off after an adjustable time delay. Current can also be set so that even if one stove plate is switched the geyser will switch off. Use PPM-05/16 for 3kW geyser. Use PPM-05/5 with CT's for larger loads For geysers use external contacts. Operating temp: -20 to 45°C N Code Type Supply *Add voltage to code Function Output relay LED Indication Dimensions PBM-01* PBM-02* Bi-stable Relay SSRC-04* Liquid Level Relay *230VAC or *24V (VAC/DC) *230VAC, 400VAC Used to control lighting or other devices by means of a pushbutton in parallel. Pushing any button causes switching on or switching off. L or N line signal PBM-02. Internal relay memory remembers postition of relay when power fails. Can be centrally controlled. SSRC-04 is used for the level and discharge control of conductive liquids in tanks located in industrial plants and domestic applications. The output relay switches ON when the liquid reaches the upper level electrode. The output relay switches OFF when the lower level electrode is no longer in contact with the liquid. The sensitivity (i.e. impedance between electrodes) can be adjusted to 5-50Ω for different liquids by means of the knob of the front panel. The LED on the front panel lights when the relay is ON position. 1C/O 8A 1NO @ 16A AC 1 4kW LED Green: Power LED LED Red: Relay on LED Test button 17.5mm width DIN mounting L Stove Geyser = Lamp to indicate that geyser is off. Stove load not to exceed 16 Amps, if larger use external CT. Eg. DS-505 50/5A with relay PPM-05/5. N L C1 LED Green: Power LED LED Red: Relay on LED CT AUTOMATION PRODUCTS 1 phase VOLTAGE & CURRENT RELAYS Geyser Stove C1 35mm width DIN mounting DPM 15 MINI DIN TIMERS, VOLTAGE & CURRENT RELAYS Monitoring Relays 35.5mm wide Code DBB51C M24* DUB71C B23* DAC51C M24 DUA52C 724 DIA53S 724* Type Delay off Star-Delta Over/Under Voltage Battery Monitor Over Current Monitor Input – – 0.1-10V AC/DC 2-500V AC/DC 8-28VDC 2-20A AC *20A 5-50A AC *50A 10-100A AC *100A Output Function Supply SPDT (with neutral posn) 5A @ 250VAC SPDT 5A @ 250VAC SPDT 5A @ 250VAC *Add to order Code Over/Under Voltage monitoring relay. 1 Phase AC/DC TRMS comparator. Set-point adjustable. Hysteresis adjustable. Time delay adjustable. For 0.1-10V CT see page 116 For use with Star-Delta motor starters. Ranges: 0.1s - 1s; 1s - 10s; 6s - 60s; 60s - 600s. Adj. delay between Star and Delta 50 to 130ms. True delay on release. *Time ranges: 1s - 10s 10s 6s - 60s 1m 60s - 600s10m DBB51 should not be operated by pulses <200ms. 115/230VAC 24 to 240VAC/DC 24VDC/24 to 240VAC *10V *500V SPDT 5A @ 250VAC NPN-PNP open collector NO(1) Under voltage monitoring relay for DC battery circuits. Measures own powesupply. Self-point adustable. Hysteresis adjustable. Taken from input Over current monitoring relay. 1 Phase AC setpoint adjustable 2 wire connection. Integral CT with 12mm dia hole. *Add CT range to order Code. (1)100mA 40VDC max 12-24VDC DIGITAL SCHOOL TIMER Electronic School Timer No. of channels Code AUTOMATION PRODUCTS SDM-10/U 16 1 Time Range 24hrs/ 7 days Total no. of programmes Working Minimum Reserve Interval 50 on + 50 off 3 years User friendly, and easy to program. Lesson times can easily be added or changed. The controller has a real time clock and calendar. Adjustable ringing duration. Width: 35mm (2 Module width) Complete with protective flap. 1 sec. Width in DIN Relay Output 2 16A, C/O Supply Voltage: 24V - 230VAC/DC Relay output rated at 16A, AC1 rating. Battery backup, preventing data loss during power failure. LED illumination of the LCD display. Able to back up programmed times for 10 years. Seasonal and holiday programming available Electronic School Control Box Code EW-01 The Electronic School Janitor is an assembled unit. Used for controlling school utilizing the SDM-10. It consists of: • Over Voltage Protection • Bell Controller (SDM-10) • Electromagnetic Relay x 2 • Alarm Button • Accoustic Alarm Indicator • Short period selection button DPM Features: Two ways of connecting directly to the school bell or connecting to the existing installation instead of manually ringing the bell. • Easily programmable timetable. • Real time clock. • Adjustable ringing duration. • Programmable alarm bells. • Seasonal and holiday programming available