CONTENTS

Transcription

CONTENTS
Angle Grinders
ACB's
534-573
307,312
373
420
35,59,200
177
542-550,
573
239-252
290
299
164-165,
168-171,
175
295
123
Batteries
- Indicators/Accessories
Battery Chargers
Borehole Depth Tester
Break-Glass Stations
Busbar Trunking Systems
Busbar & Supports
Borehole Pumps
- Controls
70,74
70-71, 77
70-75
39
365
102
146-151
50-51
40-41
Cable Accessories
317-324,
332-335
277-278,
281-282
402-404
231, 551561
10,32,211
186-187
100-104,
109
110
109, 113
111
117-122
Access Control & Security
Adaptors - Domestic
- Industrial
Air Conditioners
Air Line Controls
Alarm Annunciators
Alarm Systems
Audible & Visual Alarms
Allen Keys
AMF Controls
Ammeters
Cable Cutters
Cable Racking
Cameras
Capacitive Relay & Sensors
Capacitors
Changeover Switches
Circuit Breakers
- DIN
- 13mm Mini Rail
- MCCB
Conduit & Accessories
Contactors
Conveyor Monitoring Switches
Converters (DC to DC)
Counters
Crane and DC Vehicle Controls
Crimping Tools
Current Relays
CT's
Daylight
Dimmers
- Switches
- Relays
Din Rail
Diodes
Distribution Blocks
Distribution Boards
Door Chimes & Locks
Drill & Taps
Dust Collection Systems
Earth Braids
Earth Leakage Protection
314-315,
368
89-93,
116, 117
35
70
20-23
201-203
228-285,
334
9
116-167
511
14
13,
304-305,
384-391,
506, 518
139, 285
340
144-145
110, 116,
354, 357
536-539
287
35
150-154
109, 111,
114-115
Specifications are subject to change without notice in this publication.
CONTENTS
Electric Drills & Hammers
Electronic Education Equipment
- Instrument Enclosures
Enclosure Fittings
Enclosures
- 19"
- Aluminium
- Dbs
- Instrument
- Mild Steel
- Polycarbonate
- Polyester
- Pushbutton
- Standard Plastic
- Stainless
- Fittings
- Municipal
Energy Meters & Analysers
Energy Saving Controller
Explosion Proof Equipment
Extender Sockets
Extension Cords & Reels
Fans
Firemans Switches
- Detection Systems
- Protection
Fixture Accessories
Fish Tape
Flip Flop Relay
Float Switches
Flow Switches
Frequency Relays
Fuse Switches
Fuses & Fuse Holders
Gas Detectors
Gas Soldering Irons
Generator Controls
Generators Sets
Glands
Gloves, Safety
Grommets
Hammers
Hand & Hair Driers
Heaters
Heat Detectors
Heat Shrink
Heat Sinks
Hole Saws
Hooters
Hydrosperes
Hygiene Products
Humidity Controllers
Insect Killers & Traps
Insulators
Intercoms
Inverters (DC to AC)
Irrigation Controllers/Pool
295
276
360-363
306
342-372
346-347
131, 361
354-357,
369-372
360
349-352,
356-357
358-361
353, 360,
366
131, 348
364, 367
347-350,
366
342-345,
352, 357,
359, 365
358
173,
174-175,
180-182,
264-265
183
256-263
307
307,
312-313
410-417
239
239-240
365
325-328
316
10
32-34, 37,
43
34
9, 12
97, 99,
105
134-139
240, 257
280
184-185
299-301
317, 321,
368, 381
265
321
290
406-419
408-410,
417
240
322
31, 338
291
244,259
43
418-419,
420
193
406-407
149, 285,
322
536-572
79, 82
59
Isolators
96-105,
109, 111,
113, 117,
121
Joy Stick Controllers
Junction Boxes
127
322, 364,
367
322
Joint Kits
130,
500-510
LED's
130, 337,
483, 499
Legend Plates
130
Lighting
422-553
- Emergency
398,
475-479
- Advertising/Display
451-519
- Bulkheads
399, 429,
459
- Cabinet/Display
455
- Camping & Leisure
480-482
- Daylight/Motion Switches 511
- Dc
248,454,
506
- Downlights
435,
437-441,
456, 459
- Festive/Chandeliers
468, 520530
- Fibre-Optic
527
- Flameproof/ Explosion 256,
261-262
- Flood
400-401,
429-436
- Fluorescent
399,
422-427
- Garden
397,
462-465,
471-474
- Highbay
398, 401,
428-429
- LED
248-250,
426-435,
445-452,
462,
483-490
- LED Downlights
439,
442-444,
459
- LED Street
452
- Energy Saving Lamps 502-507
- Energy Saving Fittings 502-503
- Low Voltage
494-499,
503,
508-510
- Spot/Stage
457-464 ,
531-533
- Street
453
- Solar
253-254,
453, 526
- Pendant
466-467
- Track
469
- Lighting Control Gear 491-492,
498,
515-518
- Outdoor
397, 448451, 458
- Underwater
470-471
- Weatherproof
422
- Accessories
491-492,
513-518,
316
Lightning Protection
154-159
Limit Switches
204-207
Lamps
© Copyright - AC/DC 2010
CONTENTS
11,15,
32-36
236-238
15, 111
Sensors - Proximity
- Vision/Fibre Optic
Sequence Relays
Signal Converters & Isolators
Signal Transmitters
Smoke/Gas/Heat Detectors
Socket Outlets - Weatherproof
Soft Starters
Solar - Panel/Home Power
- Regulators/Monitors
- Mounting Accessories
SSR's
Starters - Fluorescent
- Motor
MCCB's
162
76-81
287
349, 353
163-165
168-172,
183
163
180-182
204-206
130,
508-509
161
106-107,
160
267-274
341,
380-381
117-122
Over Temperature Switches
Overload Relays
Office / Cable Routing
160
90-91
309-311
PCB Switches
Pendant Controllers
Phase Angle Relays
Phase Failure Relays
Pivot Shut-Down Relays
Pilot Lights
PLC's
Plug Tops -Domestic
Plugs & Sockets - Appliances
- Industrial
336
202
40-41
8,12,14
6,41
125 - 133
178-179
312
341
373-379,
382-383
339
156-158
173,
188-189
12,
172-174,
183, 196
267
310-311,
405
66-69
294-296
43,
198-199
43-58
40-41
87
39-40,
124-128
129
129
133
130,133
Liquid Level Controls
Loud Speakers
Load Controls
Mains Fitters
Mains Stabilisers
Measuring Tapes
Meter Boxes & Kiosks
Meter - Analoque
- Digital
- Running Hour
- KWH
Microswitches
Miniature Lamps
MOV's
Motor Protection
Multimeters
Multipole Connectors
Potentiometers
Power Protection
Power Factor Correction
Power Monitors
Power Skirting
- Digital
- Analogue
Power Supplies (AC to DC)
Power Tools
Pressure Switches & Sensors
Pumps
- Protection Relays
- Starters
- Controllers
Pushbutton - 22mm
- 30mm
- Miniature
- 16mm
- Lights
Ready Boards
Rectifiers
Relays
Rivets & Tools
Rocker Switches
Rope Pull Switches
Rotary Encoders
Running Hour Meters
Security
- DVR/CCTV
Selector Switches
42,110
340
5, 15, 19,
24-31, 116
289
132
207
184
180-182
534-574
563-567
165
- Photoelectric/Laser
- Motion (PIR)
Storage Bins
Sumersible Pump Seal Relays
Surge Protection
Swimming Pool Boxes/ Filters
Switching Accessories
AUTOMATION PRODUCTS
209-213,
227
214-228
208, 304,
387, 512
230-235
10
5-6, 12
6
240
308
86-87
83-85
83, 265
82
30-31, 192
517
89, 94-95,
108
297-298
11
156-161
42
302-303,
306-307,
384-396
TV & Audio
Two - Way Radios
7
292
37-39
255, 541
190-196
7, 14
143, 365
336
146
140-142
264-275
273, 276
266
5
197, 384389, 392
2-4, 12-13,
16-19, 59,
92, 196
132-338
279, 298
277-295
253-254
176
60-66, 116
310-311,
321
534-535
36
Ultrasonic Level Controls
UPS's
225
78, 80-81
Variable Speed Drives
Voltage Regulators
Voltage Relays
Voltage/Phase Indicators
Voltage Protection
Voltmeters
88
76-77
9, 14-16
15,
78
163-165,
168-171,
175
Water Meter Boxes
Water Taps - Automatic
Water Dispensers
Welding Machines
Weicon Adhesive/Technical Spray
Wire
Wireless Switches
Wind Turbine Generators
358
59,419
418
296
327-331
152-153
304-305
84
Tacho Relays
Taps And Drills
Telemetry Systems/ GSM
Telephone Equipment
Temperature - Controls
- Relays
Terminals - Blocks
- PCB
- Posts
- Rail Mounting
Test Instruments
Test Leads
Test Probes HV
Thermistor Relays
Thermostats
Timers
Toggle Swtiches
Tool Boxes
Tools
Traffic Lights
Transducers
Transformers
Trunking
LEVEL, PUMPS & TELEMETRY
POWER SUPPLIES & TRANSFORMERS
SOLAR & WIND GENERATORS
MOTOR CONTROL
CIRCUIT BREAKERS, FUSE GEAR & ISOLATORS
PUSHBUTTONS & PILOT LIGHTS
TERMINALS, INSULATORS & COPPER
SURGE, TEMPERATURE & NOISE PROTECTION
INSTRUMENTS
CAPACITORS & PFC
TEMPERATURE CONTROLS
CRANE & VEHICLE CONTROLS
LIMIT & PRESSURE SWITCHES & SENSORS
ALARMS & SPEAKERS
FLAMEPROOF & TELEPHONES
TEST INSTRUMENTS, TOOLS & GENSETS
WIRING ACCESSORIES
ELECTRONICS
ENCLOSURES & FITTINGS
GEWISS
FANS, INSECT PROTECTION & HYGIENE
LIGHTING
SECURITY
© Copyright - AC/DC 2010
TIMERS
Unequal
Repeating &
Delay on
Two-Shot timer
UP1/M
UP2/M DP1* DP2* DP3
UP1/MV UP2/MV
Type
Code
Outputs
SPDT
Mode of
Operation
Multi range timer.
Time ranges:
0.15S to 10S
1S to 60S
1.5S to 100S
10S to 10M
1M to 60M
10M to 10hr
Selectable by DIP
switches 1, 2, 3 & 4
at rear of timer.
Timing functions:
Unequal repeating
(off first)
Unequal repeating
(on first)
Two-shot (off first)
Two-shot (on first)
Selectable by DIP
switches 5 & 6 at rear
of timer.
UP1/MV & UP2/MV
Multivolt range
24-250VAC/DC
Connection
Diagram
AUTOMATION PRODUCTS
UP1/M
ONLY
2
Note: Standard
stock is 11 Pin.
8 Pin available
on order
Supply AC
Multivolt
Supply DC
Specification
+
DPDT
SPDT
SPDT
+INST
IP1*
SPDT
IP2* IP3
DPDT
SPDT
+INST
Upon application of the
supply voltage the delay
time period begins and
the power LED lights up.
On the expiry of the set
time the relay LED will
light up and the relay will
operate and will not
release until the supply
voltage is disconnected.
Upon application of the
supply voltage the relay
operates, the power and
relay LED lights up and
the time period begins.
On the expiry of the set
time, the relay releases
and will not operate
again, until the supply is
re-applied.
DP3: Output relay A is
instantaneous.
IP3: Output relay A is
instantaneous.
‘t’ x10
SUPPLY
VOLTAGE
DPDT
Interval
UP2/M
ONLY
–
11 Pin SPDT
Equal Repeating
Delay off
No Power
EP1*
EP2*
DDP1* DDP2* DDP3
SPDT
DPDT
SPDT DPDT
Upon application of the
supply voltage the relay
operates and the ON time
period starts. After the
ON period has expired
the relay releases and an
equal OFF time period
starts. This equal
operation continues until
the supply voltage is
disconnected.
SPDT
+INST
No power required delay
off function. Upon
application of the supply
voltage the relay
operates. When the
supply voltage is
disconnected the time
period starts and at the
end of the time period
the relay releases, the
time is reset and the
relay remains released
until the supply voltage
is reapplied. For time
ranges above 600 sec
there is a built-in battery.
This timer is not to be
used for short pulses,
as battery requires
24H to recharge.
Use IAP1or 2.
‘t’ x10
SUPPLY
VOLTAGE
11 Pin DPDT
SUPPLY
VOLTAGE
11 Pin SPDT+INST
A=Instantaneous
Contact
SUPPLY
VOLTAGE
8 Pin SPDT
SUPPLY
VOLTAGE
8 Pin DPDT
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV)
60 - 250VAC/DC (available only on models marked *)
12, 24, 48VDC
Range accuracy:
Repeatability:
Scale accuracy:
Reset time:
Operating temperature:
Power consumption AC:
1.5VA
DC:
100mA @ 12VDC
Contact rating
SPDT: 10A 250VAC
DPDT: 5A 250VAC
For external potentiometer: use 1MΩ
±5%
1%
±5%
300mSec
-20 to 70°C
M1
See Page 11 for time ranges
TIMERS
Delay on
Pulse Start
Interval
Pulse Start
WM1/M
PP1
DAP1
DAP2
IAP1*
IAP2*
2 x SPDT 2 x SPDT
SPDT
SPDT
SPDT
DPDT
SPDT
DPDT
Outstanding value,
two timers in one!
Function: When the power is
applied the contact between 1
and 4 closes. The contact
remains closed for an
adjustable forward or ON time
period. It then opens for an
adjustable pause or OFF time
period. After the pause delay,
contacts 1 & 3 close and
remain closed for a reverse or
ON time (same as the forward
time). After the reverse period
the contact between 1 & 3
opens for the pause time.
This cycle is repeated until
supply is removed.
DIP Switches 1 to 5:
On Pause & Time Ranges:
0.15s to 10s 1.5s to 100s
1s to 1m
10s to 10m
10s to 10m 100s to 100m
1m to 1h
10m to 10h
DIP switch 6: OFF. Pause
period first. ON: on period
first.
External POT 100K
Upon application of the
supply voltage the OFF
time starts. At the end of
the OFF time the relay
operates and stays in
operation for the
remaining on time.
Thereafter it returns to
the OFF position. ie. The
total OFF and ON period
is equal to the full time.
This recycling operation
will continue until the
supply voltage is
removed.
Start switch between
5 & 7: Apply supply
voltage. Upon the
closure of switch 5 & 7
the timing period starts,
irrespective of whether
the start switch is
closed or not. After the
set time the relay will
operate. To repeat this
function supply voltage
must be removed and
re-applied again.
Start switch between
6 & 7: Apply supply
voltage. Upon closure of
switch 6 & 7 nothing
happens. The timing
period will only start
when the switch
between 6 & 7 has
opened, upon opening
the timing period
begins. After the set
time the relay will
operate.
MFMR
DP/DP DP/IP
DPDT
Time ranges:
0.02 to 1S
0.15 to 10S
1S to 60S
10S to 600S
1M to 60M
10M to 10H
22M to 24H
3H45M to 240H
Selectable by DIP switches
1, 2 & 3 at rear of timer.
Functions:
Delay on (DP2)
Delay on pulse start (DAP2)
Interval timer (IP2)
Interval timer pulse start
(IAP2)
Equal repeating timer (EP2)
OFF first
Equal repeating timer (EP2)
ON first
Selectable by DIP switches
4 & 5 at rear of timer.
MFMRV: Multivolt supply
24-250VAC/DC
External POT 100K
+
SUPPLY
VOLTAGE
DP/DP
Two delay on timers
sharing common
power supply.
Independently
adjustable.
DP/IP
One delay on timer
and interval timer
sharing
common power supply.
Independently
adjustable.
–
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
Start switch between 5 & 7: Apply supply
voltage. Upon the
closure of switch
between 5 & 7 the
relay operates and the
time period starts.
When the set time has
expired the relay
releases irrespective
of whether the start
switch is still closed or
not.
Start switch between
6 & 7: Apply supply
voltage. Upon closure
of start switch
between 6 & 7 the
relay operates. The
time period only
starts from the
break of the switch.
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
SPDT
DPDT
AUTOMATION PRODUCTS
Dual Timers
MFMRV
Forward
Reverse Timer
(Multi-range)
Percentage
Timer
Multi-Range
Multi-Function
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV)
Multivolt 60-250VAC/DC (available only on models marked*).
12, 24, 48VDC
Range accuracy:
Repeatability:
Scale accuracy:
Reset time:
Operating temperature:
See Page 11 for time ranges
±5%
1%
±5%
300mSec
-20 to 70°C
Power consumption AC:
1.5VA
DC:
100mA @ 12VDC
Contact rating
SPDT: 10A 250VAC
DPDT: 5A 250VAC
For External Potentiometer use 1MΩ
M1
3
TIMERS
Type
Star-Delta
Timer
One-shot
Timer
Triac Flasher
Relay Flasher
Code
SDP1
OSP1
OSP2
TFP1
RFP1 RFP1/A DET1
Outputs
SPDT
SPDT
DPDT
Triac output
SPDT
WITHOUT
FAN DELAY
Mode of
Operation
When supply
voltage is applied
­connection between
1 and PIN 4 is
made. The time
period starts for
Star connection.
After the Star set
time has elapsed
connection between
pin 1 & 4 is opened
and stays in a
­neutral position for
100mS. After the
100mS pause
­connection is made
between pin 1 & 3
for the Delta
contactor.
LINK:5-6: Pulse on
energisation
LINK 6-7: Pulse on
de-energisation.
When the power is
applied the relay
operates for 0.5
sec. When power is
de-energised the
relay operates for
0.5 sec.
TFP1 (230VAC
only) Upon applying
the supply the lamp
will flash with an
equal on and off
time until the supply is removed.
This on and off time
is adjustable from
0.02 - 1 sec.
RFP1
On applying the
supply, the lamp will
flash with a fixed
equal on and off
time of 0.5 sec. This
will continue until
the supply is
removed. Can be
used to switch one
lamp or two alternating lamp circuits.
Upon application of
supply voltage,
cooling cycle starts,
(4, 6, 8 or 12 hrs)
followed by defrost
cycle (1-60min).
LINK 5-6: As above
except defrost cycle
starts first.
DET1/F: Is for
freezer rooms and
has additional relay
for fan delay (6-360
Sec).
Leds “defrost on”
“fan on”.
Dip switch selection:
TFP2
TFP2 (230VAC
only)
Upon applying the
supply, lamp 1 will
switch on then
switch off and then
lamp 2 will switch
on. This on and off
time is adjustable
form 0.02 - 1 sec.
Defrost Timer
RFP1/A
As per RFP1 except
that the equal on
and off time is
adjustable from 0.02
to 3 sec.
Repeating
Pulse
DET1/F RP1
WITH
FAN DELAY
SPDT
Upon application of
the supply voltage
the delay period
begins. On expiry of
the set time, the
relay pulses on for
0.5 sec and a new
time period begins.
This repeating pulse
continues until the
supply voltage is
disconnected.
cycle times
14 hour
Triac: 1000W (4A)
@ 250VAC
16 hour
18 hour
12 hour
Connection
Diagram
OSP1
C:COOLING
D:DEFROST
F:FAN
TEMP
OVERRIDE
TFP1
RFP1 & /A
AUTOMATION PRODUCTS
SUPPLY
VOLTAGE
OSP2
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
SUPPLY VOLTAGE
SUPPLY
VOLTAGE
SUPPLY VOLTAGE
Supply AC
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV)
Supply DC
12, 24, 48VDC
Specification
4
TEMP
OVERRIDE
TFP2
Power consumption:
Output rating: SPDT: 10A @ 250VAC
DPDT: 5A @ 250VAC
Triac: 1000W (4A) @ 250VAC
M1
AC 1.5VA
DC 100mA @ 12VDC
PROCESS CONTROLS
Type
Alarm Relay
3I/P
3O/P
Thermistor Relay
Single & Dual
Alarm Relay
Differential Relay
Signal Converter
Code
AL3
TH1
SAR1
DAR2
DIR
Outputs
SIC1†
SIC1†
4 x SPST
SPDT
SPDT
DPDT
Mode of
Operation
On closing of any input
contact, the
corresponding output
relay and hooter will
­energise. By using a
common flasher ­connect
to PIN 11 lamp 1 will
flash. By pressing the
accept button the lamp
will steady and remain
on until the fault is
removed, and the hooter
will stop. More alarms
can be added by merely
­commoning up more
modules with no
restriction. Pins to be
common when
expanding; 11,10, 9, 7
and common of hooter.
Failsafe design.
SAR1: Single trip point
DAR2: Two trip point
(2 relay outputs
independently
adjustable)
Latch facility
Link PINS 7-9. Relay
remains de-energised
after tripping.
To reset, break supply
voltage or operate N/C
external reset device
connected to PINS 7-9.
0-10V
This module provides a
relay output with high
and low set points from
an ­analogue instrument­
signal­.
INPUT
LINK 6 & 7
0 -20 mA
NO LINK 6 & 7
4 - 20 mA
SUPPLY
VOLTAGE
Lamp test Pin 7
Alarm accept Pin 9
Hooter Pin 8
To be utilised with
relay flasher RFP1 to Pin
11
4-20mA
The Signal Converter
­modules convert various
input signals to a 4-20mA or
0-10V DC signal. They are
intended for use with all PLC
and other instrumentation­
The relay is normally
The output relay will
systems.
de-energised and will
energise on the high set †Input selection
energise when the input point and de-energise on A: 0-5 Amps AC/DC
signal reaches the set
the low setpoint offering
B: 0-1 Amps AC/DC
level, set by a
a wide adjustable
R: Ohms
potentiometer. The relay differential­.
V: Voltage range AC/DC
will de-energise when the
Calibration: For field
input signal drops below When more than one unit calibration, energise module
the set level by 3%
is used in series and the and set input to maximum.
supply is DC, an isolator Adjust SPAN until output­is
The second alarm relay
must be used for each
20mA/10V. Set input to
operates the same but
unit:
minimum­requirement and
set at a different trip
ISO-12VDC
adjust ZERO until output is
level.
ISO-24VDC
4mA/0V. Calibration is
complete.
Red LED: Power on.
Connection
Diagram
Specification
SPDT
SIC2†
SIC2†
INPUT
LINK 6 & 7
0 - 5VDC
NO LINK 6 & 7
1 - 5VDC
SUPPLY
VOLTAGE
Tripping resistance 1.2kV Input signal:
No. of thermistors to be 4 - 20mA
conntected in series not 0 - 20mA
to exceed 1kV
or
0 - 5VDC
1 - 5VDC
SUPPLY
VOLTAGE
Input signal:
4 - 20mA
0 - 20mA
DIR
or
0 - 5VDC
DIRV
1 - 5VDC
}
}
SUPPLY
VOLTAGE
Inputs:
SIC*A: 0-5 Amps, AC/DC
SIC*B: 0-1 Amps, AC/DC
SIC*R: 1-20kV
SIC*V 10V: 0-10V, AC/DC
SIC*V 150V: 0-150V, AC/DC
SIC*V 300V: 0-300V, AC/DC
SIC*V 600V: 0-600V, AC/DC
* 1: for 4-20mA. 2: 0-10V output
Power
consumption
DC: 600mA
@12VDC
AC ± 1.5VA
Supply AC
Not Available
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Test volts 2kV)
Supply DC
12, 24VDC
Contact rating
AUTOMATION PRODUCTS
The relay is normally
energised, when one of
the thermistors reaches
tripping ­temperature the
relay de-energises. The
relay will energise when
the temperature drops to
below trip level.
DIRV
12, 24, 48VDC
SPDT: 10A @ 250VAC
M1
DPDT: 5A @ 250VAC
5
PROCESS CONTROLS
Type
Namur Sensor
Relay
Pivot Shut Down
Relay
Code
NS1
VCT1
Outputs
SPDT
SPDT
Mode of
Operation
Failsafe design.
Failsafe design.
The Namur sensor
relay converts the
changing current of an
Inductive or Capacitive
Namur sensor into a
relay switching. The
sensor can be
connected between 5
& 6 to energise the
relay when the sensor
is activated, or
between 6 & 7 to
energise the relay
when the sensor is
deactivated.
See page 210 for
Namur sensors.
Signal Isolator (Transducer)
Input
Output
4-20mA
4-20mA
For use with centre
pivot irrigation systems
to prevent overwatering
of the field.
On application of
­voltage, the output relay
energises for the
adjustable start up
delay period. Once
running, if the pivot arm
motors do not draw a
minimum adjustable
current within an
adjustable time (usually
3 ­minutes for 20%
watering), the output
contact de-energises,
switching off the Pump
Start circuit.
0-10V
Code
SI-1A
SI-1V
0-10V
4-20mA
0-10V
4-20mA
10-0V
SI-1A/V
SI-1AV REV
All outputs are galvanically isolated from
inputs.
Output: 4-20mA into 0-600 ohms load.
Isolation between IP/OP and Mains =
600V
AUTOMATION PRODUCTS
Supply AC
Supply DC
Contact rating
6
AC: ±1.5VA
–
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
Supply Voltage
A = AC 85 to 265V DC 100 to 330V
B = DC 20-60V
Speed (Frequency Transmitter)
For use with DIN type
CT-5 current transformer
(see page 128)
(Input 0-4V)
DC: 100mA @ 12VDC
1.5VA
–
SPDT: 10A @ 250VAC
P: PT100
F: 0 to 100°C
D: -50 to 200°C
G: 0 to 200°C
DC Output Multi-Range
(Selectable by DIP Switch)
V2: 0 – 5V
A2: 0 – 10mA
V3: 1 – 5V
A3: 0 – 20mA
V4: 0 – 10V A4: 4 – 20mA
A1: 0 – 1mA
Galvanic isolation with internal transformer 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
–
V2: 0 – 5V
V3: 1 – 5V
V4: 0 – 10V
A1: 0 – 1mA
A2: 0 – 10mA
A3: 0 – 20mA
A4: 4 – 20mA
RTD (PT100) Transmitter (Isolator)
A
S4X-RR-P -A4- B
+
Power
consumption
V1: 0 – 50mV
V2: 0 – 5V
V3: 1 – 5V
V4: 0 – 10V
A1: 0 – 1mA
A3: 0 – 20mA
A4: 4 – 20mA
Code: S4X-PT-A
–
Sensor current: 8mA
Open voltage: 8.5V
DC Input Range DC Output Range
Supply Voltage:
AC 85 – 265V/DC 100 – 330V
Input Potentiometer: (3 Wire)
1: Total resistance 100V – 10KV
+
Specification
Code: S4X-DT-*
*Add Supply Voltage:
A = 85 to 265VAC/100 to 330 VDC
B = 20 to 60VDC
Multi-range Input and Output
Selectable by DIP switches
on side of unit.
Potentiometer Transmitter
Connection
Diagram
SUPPLY
VOLTAGE
Signal Isolator Transmitter
–
DPDT: 5A @ 250VAC
M1
S4X-RT-B-2-M-A 0-100Hz Input
S4X-RT-E-2-M-A 0-1KHz Input
S4X-RT-F-2-M-A 0-2KHz Input
S4X-RT-H-2-M-A 0-10KHz Input
Supply Volts: 85 to 265VAC
Output Programmable: 4-20mA, 0-10V
Specification:
Accuracy: ± 0.1% RO.
Isolation: Input/Output/Power
Insulation Resistance: ≥ 100MV, DC 500V
Impulse Withstand Test: IEC 1000-4-5, class 4
PROCESS CONTROLS
Over/Under Speed &
Tacho Relay
Three Start
Attempt Relay
Coincidence Relay
TSAP1
CS1
Start: SPDT
Alarm: SPDT
SPDT
Failsafe design.
External contacts A and B
typically are pushbuttons
mounted 1m + apart on a
press or
guillotine. The operator must
press both buttons, keeping
his hands safely away,
before the machine operates.
Apply the supply
voltage. The contacts
A & B must be actuated within 0.5s in order to make the
relay operate. If one of the
contacts is interrupted the
relay will immediately
release.
Upon application of the supply voltage, the ‘start’ relay
operates for a set ‘on’ duration followed by a set ‘dwell’
cycle. After the relay has
operated for the no. of starts
as per the dip switches and
the supply voltage is still
present, the ‘alarm’ relay will
operate and this condition
will prevail until the supply
voltage is removed.
Dip switch setting: 3-6 starts
Start time: 0.5-30sec adjustable.
TM1
TM4
TM4/R
SPDT
Failsafe design.
Ideal for use in machine
safety guard systems.
Failsafe design.
The Tacho relay connects to a
PNP,NPN or Namur inductive
or capacitive sensor.
Under Speed: Link 5 & 11.
The relay energises if input
speed drops below the set
limit.
Over Speed: No link 5 & 11.
The relay energises when the
speed exceeds the set limit.
DIP SW: SW1 ON: NPN
SW1 OFF: PNP
Output TM4:
SW2 ON: 4-20mA
SW2 OFF: 0-20mA
Ranges:
Posn RPM
1
2-20
2
5-50
3
10-100
4
20-200
5
50-500
Posn RPM
6
100-1k
7
200-2k
8
500-5k
9
1k-10k
10 2k-20k
Temperature Relay
for T/C: J & K
TRJ2
TRK2
TRJ4
TRK4
SPD
SPDT
0 to
400°C
0 to
200°C
Failsafe design.
TRJ2 & TRJ4 for
J type thermocouple
TRK2 & TRK4 for
K type thermocouple
The temperature relay connects to a temperature
sensor. The relay energises when the temperature
exceeds the set limit. The
relay de-energises when
the temperature drops
below the set limit.
Remote control available
on request.
Temperature Relay for
T/C: PT100
SPDT -20 to +80°C TR1
SPDT
0 to 100°C
SPDT +50 to 150°C
SPDT +50 to 200°C
TR2
TR3
TR4
Failsafe design.
Link 8 & 9: (under temp).
The temperature relay connects to a temperature sensor PT100. The relay energises when the temperature
exceeds the set limit. The
relay de-energises when the
temperature drops below the
set limit.
NO Link 8 & 9: (over temp).
The relay ener­gises on application of power and will deenergise when the temp.
exceeds the set value.
AC Supply only
PNP OR NPN
Supply Voltage:
9-30VDC ­standard.
Other Voltages available
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
TM1 - 1mA Output
TM4 - 4-20mA Output
TM5 - 0-20mA Output
TM4/R - Remote 1MV pot
Hysteresis: 3% fixed
Namur connect 6-7
NPN/PNP connect 5-6-7
AC: ±1.5VA
Control: On/Off
Proportional on request
Latch: Pin 8 & 9
Hysteresis 3% fixed
Faulty thermocouple
Indication: Flashing LED
SUPPLY
VOLTAGE
AUTOMATION PRODUCTS
SUPPLY
VOLTAGE
Overtemp: No link between
PINS 8 & 9
Undertemp: Link 8 & 9
Hysteresis: 0 - 100%
DC: 100mA @ 12VDC
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
SPDT: 10A @ 250VAC
M1
DPDT: 5A @ 250VAC
7
POWER MONITORS
Type
Phase Failure &
Sequence Relay
Phase Failure &
Sequence Relay
Supply
Protection Relay
Over & Under Voltage
Three Phase
Code
SMP1 1000
SMP1
SMP1/N
SMP2
SMP2/N
SPR3
TWCP1
Outputs
SPDT
SPDT
DPDT
Mode of
Operation
Failsafe design.
Failsafe design.
This three phase (3 wire) unit
monitors the supply voltage for
all systems between 525 and
1000V. The output relay
­energises if the phases are all
­present and in the correct
sequence. The relay
de-energises when any phase is
lost or the phase sequence is
incorrect.
The unit is housed in a DIN rail
mounting housing ­suitable for
1000V ­connections.
This three phase (3 or 4 wire) unit
monitors the supply voltages. The
output relay energises if the phases
are all present, in the correct
sequence and each voltage is within
5-15% range (adjustable) of each
other. The relay de-energises on:
a. A phase voltage imbalance
exceeding the adj limit (5-15%).
b. Total failure of one or more
­phases.
c. Incorrect phase sequence.
d. Supply exceeds 15% under/over
nominal voltage (Link 2-10
options).
Built-in optional facilities (SMP1 &
SMP1/N only)
1. 180 sec fault restart delay.
2. 15% fixed over/under voltage.
These facilities can be utilised by
connecting external links as per the
diagram below.
SPR3/N
SPDT
SPDT
Failsafe design.
SPR3: 3 Phase (3 wires)
SPR3/N: 3 Phase + N (4 wires)
This three phase (3 or 4 wire) unit monitors the
supply voltage and combines the protection
features of the SMP1 and TWCP1. The output
relay energises if the phases are all present, in
the correct sequence and each voltage is to
within the adjustable over and undervoltage
limits.
The relay de-energises on:
a. Phase voltage imbalance exceeding the
10% (preset)
b. Total failure of one or more phases.
c. Incorrect phase sequence.
d. Any phase falling outside the set voltage
range.
Built-in optional facilities:
1. External latch N/C
2. 10 sec start up delay
3. 180 sec fault restart delay
These facilities can be utilised by connecting
external links as per the diagram below.
TWCP1/N
Failsafe design.
TWCP1: 3 Phase (3 wires)
TWCP1/N: 3 Phase + N
(4 wires)
This three phase (3 or 4 wire)
window voltage comparator
monitors the supply voltage. The
output relay energises if the
voltage level is within the
adjustable over and undervoltage
limits and de-energises when the
voltage is outside this range.
Built-in optional facilities:
1. External latch
2. 10 sec start up delay
3. 180 sec fault restart delay
These facilities can be utilised by
connecting external links as per
the diagram below.
Connection
Diagram
AUTOMATION PRODUCTS
SMP1 ONLY
Specification
Hystersis
Contact rating
8
N: FOR SPR3/N
N: FOR TWCP1/N
For any 3 phase system with a
SMP1 & SMP2 – 3 Phase
nominal voltage from 525 to 1000V. SMP1/N & SMP2/N – 3Phase + N
Phase imbalance: 5-15% ADJ.
LED:
SMP1 & SMP1/N only
Supply healthy – Green
Link 8 & 9
180sec fault restart delay
DIN mounting housing
Link 2 & 10 for SMP1 only
15% fixed over/under voltage protection.
LED:
Supply healthy – Green
Available for 110, 230, 400V and 525V
systems
Link 8 & 9
External latch
Link 9 & 10
10 sec start up delay
Link 9 & 11
180 sec fault restart delay.
Phase imbalance: 10% fixed
Overvolts 0 - 20% ADJ.
Undervolts 0 - 20% ADJ.
LEDs:
Over/Undervolt – Red
Phase rotation – Red x2
Supply healthy – Green
Link 8 & 9
Ext. Latch N/C
Link 9 & 10
10 sec start up delay
Link 9 & 11
180 sec fault restart delay
Overvolts 5 - 20% ADJ.
Undervolts 5 to 20% ADJ
LEDs:
Over voltage – Red
Undervoltage – Red
Supply healthy – Green
2% Fixed
2% Fixed
2% Fixed
N: FOR SMP1/N ONLY
2% Fixed
SPDT: 10A @ 250VAC
M1
DPDT: 5A @ 250VAC
POWER MONITORS
Over Current
Monitor
Under Current
Monitor
Over & Under
Current Monitor
Over & Under
Frequency Monitor
WCPT1
VCP1
VCP1/M OCP1
OCP1/D UCP1
UCP1/D CWP1
FR1
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
Failsafe design.
Failsafe design.
This new single phase
­window voltage comparator
replaces WCP1 and
monitors the supply voltage.
The ­output relay energises if
the voltage level is within
the adjustable over and
undervoltage limits and
de-energises when the
voltage is outside this
range.
Built-in optional facilities:
1. External latch
2. 10 sec start up delay
3. 180 sec fault restart delay
These facilities can be
utilised by connecting
external links as per the
diagram below.
SUPPLY
VOLTAGE
The output relay is
energised when the
voltage peak (peak
voltage on AC)
overshoots the level
selected on the front
face potentiometer. It
de-energises when
voltage falls below the
normal voltage Ue by
5-50% or when supply
breaks.
The hysteresis is
adjustable and its
selection does not
change the chosen
voltage level.
SUPPLY
VOLTAGE
SPDT
SPDT
SPDT
CWP1 - 1A/5A AC/DC
The relay senses the
OCP1 - 1A/5A AC/DC
UCP1 - 1A/5A AC/DC
OCP1/D - 60mV/150mV UCP1/D - 60mV/150mV input current and the
relay will energise, if the
AC/DC
AC/DC
current is within the set
overcurrent and
Trip Point - The relay
Trip Point - The relay
undercurrent.
de-energises when the de-energises when the The relay will
input current rises above input current drops
de-energise if the
the set point and
below the set point and ­current rises above the
energises when the
energises when the
overcurrent ­setpoint or
input ­current falls a
input ­current rises a
drops below the under­
certain percentage
certain percentage
current setpoint.
(hysteresis) below the
(hysteresis) above the
set point.
set point.
LEDs:
Hysteresis - The
Hysteresis - The
­difference between the ­difference between the Over current – Red
Under current – Red
trip level and the set
set trip level and the
level.
recovery level.
Supply on – Green
Failsafe design.
Failsafe design.
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
Link 8 & 9
External latch N/C
Link 8 & 7
10 sec start up delay.
Link 8 & 6
180 sec fault restart delay.
Overvolts 5 - 30% ADJ.
Undervolts 5 to 30% ADJ.
LEDs:
Over voltage – Red
Under voltage – Red
Supply healthy – Green
VCP1/M: Multi voltage
inputs:
UCP1
OCP1
CWP1
Connect:
Input:
5-8 0 -10VAC (RMS) DC AC: 0 - 1A
6-8 0.4 -40VAC (RMS) DC Pins 5 +7
7-8 4 -400VAC (RMS) DC 0 - 5A
11-8 6 -600VAC (RMS) DC Pins 6 +7
Startup delay: 10 seconds
For external pot use 10kV
UCP1/D
OCP1/D
2% Fixed
5 - 50% Adjustable
2% Fixed
DC: 0 - 150MV
Pins 5 +7
0 - 60MV
Pins 6 +7
5 - 50% Adjustable
SPDT: 10A @ 250VAC
M1
Failsafe design.
The unit senses the
supply frequency and
the relay will energise if
the ­frequency is within
the set over ­frequency
limits.
The relay will
de-energise if the
­frequency rises above
the over frequency
setpoint or drops below
the under frequency
­setpoint.
Link 6 & 5: Under Hz
Link 6 & 7: Over Hz
SUPPLY
VOLTAGE
AUTOMATION PRODUCTS
Over & Under
Voltage Single Phase Voltage Monitor
Response delay: 1 sec
Over: 52 - 58Hz
adjustable
Under: 48 - 42Hz
adjustable
LEDs:
Over frequency – Red
Under frequency – Red
Supply on – Green
2% Fixed
DPDT: 5A @ 250VAC
9
LEVEL AND PUMP CONTROL
Flip-Flop Relay Pulse
Start
Flip-Flop Mains
Controlled
Pump Sequence
Control Relay
FNCP1
FFCP1
FFP1
FFP2
FFP3
FFP4
SPDT
SPDT
SPDT
SPDT
DPDT
3 Pumps
4 Pumps
Failsafe design.
For alternating pumps
FNCP1 (No memory)
Closing of contact across 5 & 7
the relay will energise. Closure
of contact again, the relay will
de-energise. When the relay is
in the ON position and the
­supply voltage is removed, the
relay will reset. (No memory).
Type
Capacitive
Level Relay
Code
CLR1
Outputs
Mode of
Operation
CLR2
CLR1
Using NPN Probe
Filling: The relay energises
when the level drops below the
lower level sensor and
­de-energises when it reaches
the high level ­sensor.
Emptying: As above with
­opposite function. Link 7 & 9.
Using PNP Probe
Functions reverse.
NPN Sensor: SD10G-ARN1
Page 32
NPN Sensor: CS-09 Page 211
CLR2
2 Wire Probe ­connection:
Probe 1 5(+) 6(–)
Probe 2 7(+) 6(–)
Probes VR1A or VR1B Pg. 32.
Single Probe ­connection:
Probe 5(+) 7(–)
FFCP1 (With memory)
Closure of contact across 5 &
7, the relay will energise. On
closure of the contact again the
relay will
de-energise. The relay
remains in this position even
on removal of supply. (with
memory).
Mains controlled: Change on
removal of supply.
The relay is initially in any state, on
or off, apply supply voltage. The
relay keeps its state. Remove the
supply voltage. The relay will now
change state and will keep its state
without the supply. Apply and
remove the supply again for the
next change in state.
Mains controlled: Change on
application of supply.
Link pins 5 and 7 (Link A). Apply
supply voltage. The relay changes
state. Remove supply. The relay
keeps its state.
Pulse controlled. Link pins 6 and
7 (Link B). The relay is initi­ally in
any state, apply supply voltage. The
relay keeps its state. When the contact between pins 5 and 7 closes,
the relay will change state. Remove
the supply voltage. The relay will
keep its state without the supply.
Minimum time supply connected for
relay to react: 1 second.
NB: Voltage Free Inputs
Connection
Diagram
FFP3
AUTOMATION PRODUCTS
CLR1
SUPPLY
VOLTAGE
Response time: 500mS
Sensor connections NPN:
Pin 5 (P) H Level - Black
Pin 6 (P) Common - Brown
Pin 7 (N) Common Blue
Pin 8 (P) L Level - Black
Use VP02E or CS09
Power
consumption
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
FFCP1: Not available in 12VDC
AC: ± 1.5VA
SUPPLY
VOLTAGE
FFP4
Response time: 0.2S
Not available in 12VDC
DC: 100mA @ 12VDC
Supply AC
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
Supply DC
12, 24, 48VDC
Contact rating
10
Float or Pressure switches are
­connect­ed to pins 1, 11, 6 and ­common
on 5.
When the first switch closes, relay 1
energises. When the second and third
switches close, the second and third
relays energise. There will always be as
many relays energised as there are
input switches closed. When 1, 2 or 3
pressure switches open, 1, 2 or 3 relays
will de-energise. The positions of the
pressure switches do not matter, only
how many are switched on at a time.
When all switches open and no
relays are energised, and a switch
closes again, then relay 2 will be the
primary relay, that is the first relay to
energise, then relay 3, and then relay 4
or 1. Every time the first switch closes,
the next relay will be the first to
­energise.
The supply must be connected for
the relays to energise. The currently
selected primary relay is stored in nonvolatile memory. The relay will remember which relay to energise first, even if
the supply is disconnected.
SPDT: 10A @ 250VAC
M1
DPDT: 5A @ 250VAC
See also Phase Angle relays Page 41
LEVEL AND PUMP CONTROL
ACCESSORIES
For Plug-In Modules
BC
B2
2-Level Liquid
Level Relay
3-Level Liquid
Level Relay
Submersible Pump
Seal Monitor
TE101
TE201
DLR
SPSM1
SPDT
DPDT
DLRA
DPST
Failsafe design.
Filling: Link 7 & 8. The relay
energises when the level drops
below the low level probe and deenergises when it reaches the high
level probe. Top and bottom
probes are interchangeable.
Emptying: No link between 7 & 8.
The relay energises when the level
reaches the high probe and deenergises when it drops below the
low probe.
• For single level sensing connect
pins 5 & 6 (Probes 5 & 7).
• 1s response time to limit effect
of water ripple. Longer times manufactured to order.
TE101B: Dual voltage 230/400V
For Probes, see Pg. 32
Accessories
SPDT
Failsafe design.
Failsafe design.
DLR
For alternating pumps
There are two relay outputs with flip-flop
action each cycle for alternating duty of
pumps. Relay is connected to four
probes .
Filling: Link 7 & 8. Pump 1 starts
when the level drops below the start
level probe. Pump 2 will start if the
level drops to the ­second probe. Both
pumps run until tank is full. The next
cycle pump 2 first then pump 1.
Emptying: No link between 7 & 8.
Function as above but reversed.
DLRA
For one pump & alarm
Output relay energises and de-energises between 2 levels like TE101. When
extreme level is reached, the alarm output energises (2nd Relay).
Alarm can be used for high or low function.
For Probes, see Pg. 32
RC
For protection of submersible
motors against damage caused by
the ingress of water.
Terminals 5 & 7 ­connect to the
­monitoring terminals on the
­submersible motor.
The output relay energises upon
­application of power. The relay will
de-energise if probe current is
more than 20µA or if probe resistance is less than 1Mohm. The
relay will ­energise if probe current
is less than 15µA or if probe resistance is more than 1,4Mohm.
Timer box - Black
Retaining clip
11 Pin base cover
Bezel for panel mount
Remote pot. 1mV
Remote pot. 10kV
Code
A1024BK
RC
BC
B2
POT 1MEG
POT 10K
External dimensions (mm) A1024BK
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
Max Voltage on probe = 24VDC
Max Current through probe =
120µA = 0.12mA.
LEDs:
Power on – Red
Seal healthy – Green
Level sensor:
Probe volts 5 VAC @ 1.5mA
Adjustable sensitivity: 0 - 50 kV
AC: ± 1.5VA
DC: 100mA @ 12VDC
Galvanic isolation with internal transformer 12, 24, 48, 110, 230, 400, 525VAC ±15% (Isolation test volts 2kV)
12, 24, 48VDC
SPDT: 10A @ 250VAC
DPDT: 5A @ 250VAC
M1
0.02 - 1 sec
0.05 - 3 sec
0.20 - 10 sec
0.50 - 30 sec
1 - 60 sec
3 - 180 sec
6 - 360 sec
10 - 600 sec
0.25 - 15 min
0.05 - 30 min
1 - 60 min
2 - 120 min
3 - 180 min
0.08 - 5 hours
0.1 - 6 hours
0.13 - 8 hours
0.26 - 16 hours
0.4 - 24 hours
All timers, 11 Pin and 8 Pin, above
360 seconds: prices differ.
8-Pin plug in timers
The following timers are available in
8 Pin: DP1, DP2, DP3, IP2, IP3, EP1,
EP2, UP1, UP2, DDP1, DDP2,
DDP3, DAP1, IAP1, SDP1, PP1,
TSP1 and OSP1.
AUTOMATION PRODUCTS
Standard time ranges
11
DIGITAL POWER MONITORS
Operation
Code
Output
Mounting
Specification
Digital 3-Phase Voltage Relay
0-999
AEVR-YH 400VAC
AEVR-Y4 (400VAC+N)
Digital Frequency Relay
0-99.9
AEFR-Y
8 PIN plug-in/Flush mount
8 PIN plug-in/Flush mount
11 PIN plug-in
• Over and Under Voltage
detection which is adjustable.
• Over and Under Voltage Trip
Delay adjustable 0.1-10 sec.
• Phase Loss Detection.
• Phase Sequence detection.
• Phase Imbalance.
• Manual/Auto Reset with 1-5 sec
trip delay.
• Cutout Size: 62 x 50mm.
• Over Frequency: 50Hz-99Hz.
• Under Frequency: 10Hz-60Hz.
• Trip Delay: 1-10sec.
• Manual/Auto Reset with 1-5 sec
trip delay.
• Cutout Size: 62 x 50mm.
• Delay on Operation.
• Supply Voltage: 230VAC,
110VAC, 24VAC/DC, 12VAC/DC.
• Accuracy: < 0.3%.
• Power consumption: < 3W.
• Master reset on closure of
contact on Pins 5 & 6.
• Pause on closure of contact on
Pins 5 & 6, timer will continue on
opening of contact.
SUPPLY
VOLTAGE
Range
9999 (S) (H) (M),
99M 59S, 99H 59S
99 Days 23H
Supply:
AC: 110 and 230VAC
Code
NT-411
Signal Converter/
Isolator
ETK-MT3
Programmable Analogue + Alarm
(open collector) min/max
DIN Mounting
Microprocessor based intelligent
module for temperature sensor
and other analog signal inputs.
ETK-MT offers: • conversion
capability from low level input
signal into high level standard
output • linearization and/or
modification of the measured
value • galvanic isolation between
input and output • min and/or max
alarm threshold with common
output.
Specifications:
SUPPLY
VOLTAGE
SUPPLY
VOLTAGE
85-264VAC
DIN Timers
Description
Time Range
Code
Delay on Timer
0.1-10secs
NTE8-10B
10-120secs
Contacts:
5A @ 250VAC
Operation:
4 digit setting & ­display
timer with multi output
mode: delay auto reset.
Auto/man reset and self
hold, Instant reset.
Remote start/stop and
reset.
Mounting:
72 x 72mm
SIGNAL
CONVERTER/
ISOLATOR
(14-36VDC)
Relay 5A @ 250VAC
Digital Timer with Display
AUTOMATION PRODUCTS
AS14S
Relay 5A @ 250VAC
AEVR-YH no neutral
AEVR-Y4 with neutral
12
Digital Delay On Timer
0.025 to 99H99M
Relay 5A @ 250VAC
Connection
Diagram
Diagram:
DIGITAL MULTIRANGE TIMER
0.5-8mins (480secs)
Pulse Start Interval Timer 0.5-8mins (480secs)
Contact:
N/O 5 Amp @ 230VAC
Supply:
230VAC
Connection
Diagram
DPM
NTE8-120B
NTE8-480B
NTE8-480A
• Input Programme: TC/RTD
(3 & 4 Wires)
• Range & Minimum Span
(Programmable)
• Digital Input Filter (high noise
attenuation): 4 levels
­configurable
• Input Impedance:
>1 mOhm (in V) >10 mOhm (in
mV) >10 ohm (in mA)
• Open Input Detection
­(thermocouple): out
> max +5%
• Sensor Current (RTD,
­resistance, potentiometer):
200µA ( 3 Wires) 400µA
(4 Wires)
• Sensor Wire Resistance (RTD,
resistance, potentiometer): <500
Ohm
• ETK-MT3 Programmable; Output
0-20/4-20mA 0-10/ -5+5VDC
• Output Resolution: 4000 points
• Alarms: min and/or max
(configurable by PC)
• Alarm Output: Open collector
(isolated 2500Vrms)
• Sampling Time: 35msec
• Response Time: 200msec
Programming Software
ETK-MT
Code
Software package for the
­configuration of = input, working
range, output type, digital input
filter and alarm thresholds
Timers
MINI DIN TIMERS, STAIRCASE TIMERS & DIMMERS
Operating temp:
-20 to 60°C
Type
PCM-04*
PCM-10*
Multi-functional Timer
Multi-functional Timer
Output Relay 1 C/O - 16A
1 C/O - 16A
Function
This multi-function timer has 10 This multi-function timer has 10
independant operating modes. independant operating modes.
Wide time adjustment 0.1sec to Wide time adjustment
10 days.
0.1sec to 100 days.
• Delay ON operate.
• Unequal repeating OFF first.
• Delay OFF (Interval).
• Unequal repeating ON first.
• Repeating starting with OFF. • Two shot timer ON first.
• Repeating starting with ON • Two shot timer OFF first.
• Delay pulse on 0.5 secs • Permanent switch ON mode.
• Interval pulse start on rising edge. • Permanent switch OFF
• Interval pulse start on mode.
falling edge.
•Switch ON pulse start T1 • Bistable relay with time delay and pulse OFF T2 delay.
• Switch ON/OFF delay. •Pulse start interval T1, • Interval pulse start with second pulse T2.
•ON pulse OFF starts T1 & T2
retriggering.
Supply
*230VAC,
* Add voltage to code *24V(AC/DC)
Operating temp:
-20 to 45°C
Code
PCM-03/U
PCM-03* (12-240VAC/DC)
Type
Time
Output relay
Function
Cycling Timer
0.1 Sec - 10 Days
1 C/O - 16A
The one mode time relay
has an equal ON/ OFF
repeating time delay
starting with OFF.
Wide time adjustment
range: 0.1sec to 10 days
Power & Relay ON LED.
Accuracy 0.2%.
Supply
*230VAC
* Add voltage to code *24V (AC/DC)
*230VAC,
*24V(AC/DC)
IP65
PCM-01*
PCM-01/U
(12-240VAC/DC)
PCM-02*
PCM-02/U
(12-240VAC/DC
Delay ON
Delay OFF (Internal)
1 C/O - 16A
The one mode time relay has
a delayed switch on function.
The relay is released by
power to the system.
Wide time adjustment range:
0.1sec to 10 days.
Power & Relay ON LED.
Accuracy 0.2%.
1 C/O - 16A
Upon application of the
supply voltage the relay
operates and the time starts.
On the expiry of the set time
the relay releases. The relay
is reset by Power OFF to the
relay. Wide time adjustment
range: 0.1sec to 10 days.
Power & Relay ON LED.
Accuracy 0.2%.
PCM-06/U
Delay OFF (no power)
or Delay ON
2 C/O 8A
Mode A: On application of
the supply voltage the relay
operates when the supply
volage is disconnected the
timer period starts. After the
adjusted time is over the
relay releases.
Time ADJ 0.15s-10m for
delay OFF.
Time ADJ 0.1s-1h for delay ON
Power & Relay on LED
Accuracy 0.2%
Mode B: Delay ON
operation
*230VAC,
*24V(AC/DC)
*230VAC,
*24V(AC/DC)
12-240VAC/ DC
IP40
ASH-01/U
ASM-01/U
DIP-02
DIM-20
Staircase Timer
10 Sec - 10 Min
1NO - 16A
Staircase, corridor time
delay device. Operating
time adjustable from 10
secs to 10mins by means
of potentiometer. 2 Way
switching. 3-wire or 4-wire
installation.
Size: 69 x 56 x 27mm
Staircase Timer
10 Sec - 10 Min
1NO - 16A
Similar to ASH-01 but in DIN
Power: Red LED indication
Time adjustment: 10 secs to
10mins
1 Module width
Light Dimmer
–
–
Light intensity memory.
Compact Design. LED
indicator. 3 Wire design. Can
fit into 4x2 flush box. Triac
Output. Wiring: Black: Live
Brown: Load
Red: Switch
Size: 50 x 50 x 26mm
Max load: 350VA
Resistive load
Min load: 30VA
Light Dimmer
–
–
Intelligent dimmer lighting
control unit for resistive,
inductive loads or
electronic ballasts and
dimmable energy saving
flourescent lamps. DIN Rail
Mount. LED indicates load
on. Lighting level memory
when power OFF. Energy
saving in Stand-by mode.
Max load: 500VA Resistive
or inductive load. Min:30VA
12-240VAC/ DC
12-240VAC/ DC
230VAC
230VAC 50/60Hz
DPM
AUTOMATION PRODUCTS
Code
13
PHASE FAILURE, VOLTAGE, DAYLIGHT & TEMPERATURE RELAYS
Operating temp:
-20 to 60°C
IP65
Code
CKM-01
Type
3 Phase Failure &
Sequence
Output Relay 1 C/O - 10A
Phase sequence, total
Function
and partial loss monitoring
device. Monitors wrong
phase sequence, or loss
of one phase. < 180V
Switch on Delay: 5-10 Secs
Switch off Delay: 1-5 Secs
Voltage Threshold ADJ
170 - 200V
Hysteresis ±10V
Correct / wrong phase
seq. LED
Supply
CKH-01
PNM-10
3 Phase Failure &
Sequence
1 C/O - 10A
Phase sequence, total and
partial loss monitoring
device. Monitors wrong
phase sequence, or loss of
one phase. < 180V
Switch on Delay: 5-10 Secs
Switch off Delay: 1-5 Secs
Voltage Threshold 185V
Hysteresis ±10V
Correct / wrong phase
seq. LED
Powered from own supply
Powered from own supply 400V + N
400V + N
1 phase Over/ Under
Voltage Relay
1 C/O - 10A
Over/ under Voltage
monitoring relay. Single
phase monitoring
Minimum and Maximum
voltage adjustment
Min value: 170V - 225V
Max value: 235V - 290V
Switch off time delay
adjustment: 0 to 12Secs
230VAC 50/60Hz
Operating temp: IP65
-20 to 45°C
AUTOMATION PRODUCTS
Code
14
WZH-01
WZM-01
Daylight Relay
Type
230VAC 50/60Hz
Supply
Output relay 1NO - 16A
Used to control lighting
Function
depending on lux density
levels. The unit is
resistant to momentary
changes in lighting levels
Lux adj 0.1 to 200Lx
Photocell included
Size: 69 x 56 x 27mm
Switching delay: 30S
Hysteresis: +5-60Lux
Daylight Relay
230VAC 50/60Hz
1 C/O - 16A
Used to control lighting depending on lux
density levels. The unit is resistant to
momentary changes in lighting levels
Requires Light Sensor
Lux adj 0.1 to 200Lx
Sensor cable max length 50m
Switching delay: 30S
Hysteresis: +5-60Lux
Daylight Sensor
Daylight Sensor
Code
SOH-*
The SOH-0* is designed
for operation with the
Daylight Switches.
*01: 1m connecting cable.
*03: 3m connecting cable
*05: 5m connecting cable
Code
IP54
DPM
PNM-32
3 phase Over/ Under
Voltage Relay
1 C/O - 16A
Over/ under Voltage
monitoring relay. Three
phase monitoring
Minimum and Maximum
voltage adjustment
Min value: 170V - 225V
Max value: 235V - 290V
Switch off delay 5 secs
Phase seq. LED
Voltage asymmetry
LED
L1, L2, L3 phase LED
Relay ON LED
Powered from own
supply 400V + N
Digital Display Over/ Under
Voltage Phase Failure
1 C/O 16A
Protection of 3 phase systems against:
• Phase sequence
• Phase failure
• Over/ Under volts
adjustable 170-225V
235-290V
phase to neutral volts
• Features:
- Delay ON time setting 2-15s
- Delay OFF time setting 2-15s
- Voltage histeresis 1-4V
- Voltage asymmetry level
setting 10-60V
Powered from own supply
400V + N
RTM-01
Temperature Regulator
230VAC, 50/60Hz
1 C/O - 16A
DIN mounted temperature
controller. -5°C to 40°C.
Underfloor heating etc.
For use with standard NTC
sensor, from 3m to 50m
(See below)
RTM-20
Code
IP67
RTM-30
Digital Temp Regulator
230VAC 50/60Hz
1C/O - 16A
RTM-20: -5°C to 60°C.
RTM-30: -10˚C to 90˚C
Underfloor heating etc. LCD display
No freeze, comfort, economy modes
Indication of temp value and
adjustable temp required.
24hr 7day ON/ OFF settings
RTM-20 Heating only
RTM-30 Heating & cooling
For use with standard NTC sensor,
from 3m to 50m. (See below)
Temperature Sensor
SOS-01
The SOS-01 is a standalone sensor. To be used
with WZM-01. The length of
the interconnecting cable
may not exceed 50m.
PNM-31
NTC-03
For use with the RTM-01 and
RTM-20 temperature regulator.
Cable length: 3m (can be
extended up to 50m)
Temperature -5°C to 60°C
Code
Type
Output Relay
Function
Supply
3 phase
LDM-10
LDM-30
Voltage Indicator
–
–
The module is used for graphical presentation of
either one phase or three phase voltage supply
system levels. The voltage value is shown by
lines of LEDs.
Range from 195V to 254VAC PH/N
LDM-30 Loss of L1 will cause total switch off
Input voltage tolerance: -15-10%
LDM-10: 1 phase 230VAC monitoring
LDM-30: 3 phase 400 VAC + N monitoring
PMH-01
PMM-01
Over Current Limiter
1 NO - 16A
AC1 4kW
Used to monitor and
switch off supply when
the Load power value
has been exceeded, Adj:
0.2 - 2kW. Unit
measures current every
40 secs.
230VAC 50/60Hz
Over Current Limiter
1 NO - 16A
AC1 4kW
Used to monitor and
switch off supply when
the Load power value
has been exceeded, Adj:
0.2 - 2kW. Unit
measures current every
40 secs.
230VAC 50/60Hz
PPM-05/5 (0.5-5A)
PPM-05/16 (1.6-16A)
Load Control Relay
1 C/O - 16A
AC1 4kW
When the adjusted current value is
exceeded (term 1, 2) the monitor
switches off the non-priority load, with
the adjusted time delay. Current values
and time delay can be adjusted.
230VAC 50/60Hz
On application of the supply voltage, the
relay will energise, and the geyser will
switch on. Current adjustment can be set
so that if one stove plate is on, the geyser will remain on. When the second
stove plate is switched on the geyser will
be switched off after an adjustable time
delay. Current can also be set so that
even if one stove plate is switched the
geyser will switch off.
Use PPM-05/16 for 3kW geyser.
Use PPM-05/5 with CT's for larger loads
For geysers use external contacts.
Operating temp:
-20 to 45°C
N
Code
Type
Supply
*Add voltage to code
Function
Output relay
LED
Indication
Dimensions
PBM-01*
PBM-02*
Bi-stable Relay
SSRC-04*
Liquid Level Relay
*230VAC or *24V (VAC/DC)
*230VAC, 400VAC
Used to control lighting or other devices by
means of a pushbutton in parallel. Pushing
any button causes switching on or switching
off. L or N line signal PBM-02. Internal relay
memory remembers postition of relay when
power fails. Can be centrally controlled.
SSRC-04 is used for the level and discharge control of
conductive liquids in tanks located in industrial plants
and domestic applications. The output relay switches
ON when the liquid reaches the upper level electrode.
The output relay switches OFF when the lower level
electrode is no longer in contact with the liquid. The
sensitivity (i.e. impedance between electrodes) can be
adjusted to 5-50Ω for different liquids by means of the
knob of the front panel. The LED on the front panel
lights when the relay is ON position.
1C/O 8A
1NO @ 16A
AC 1 4kW
LED Green: Power LED
LED Red: Relay on LED
Test button
17.5mm width
DIN mounting
L
Stove
Geyser
= Lamp to indicate that geyser is off.
Stove load not to exceed 16 Amps, if
larger use external CT. Eg. DS-505
50/5A with relay PPM-05/5.
N
L
C1
LED Green: Power LED
LED Red: Relay on LED
CT
AUTOMATION PRODUCTS
1 phase
VOLTAGE & CURRENT RELAYS
Geyser
Stove
C1
35mm width DIN mounting
DPM
15
MINI DIN TIMERS, VOLTAGE & CURRENT RELAYS
Monitoring
Relays
35.5mm wide
Code
DBB51C M24*
DUB71C B23*
DAC51C M24
DUA52C 724
DIA53S 724*
Type
Delay off
Star-Delta
Over/Under Voltage
Battery Monitor
Over Current Monitor
Input
–
–
0.1-10V AC/DC
2-500V AC/DC
8-28VDC
2-20A AC
*20A
5-50A AC
*50A
10-100A AC *100A
Output
Function
Supply
SPDT (with neutral posn)
5A @ 250VAC
SPDT
5A @ 250VAC
SPDT
5A @ 250VAC
*Add to order Code
Over/Under Voltage
monitoring relay.
1 Phase AC/DC TRMS
comparator. Set-point
adjustable. Hysteresis
adjustable. Time delay
adjustable. For 0.1-10V
CT see page 116
For use with Star-Delta
motor starters.
Ranges: 0.1s - 1s;
1s - 10s; 6s - 60s;
60s - 600s. Adj. delay
between Star and Delta
50 to 130ms.
True delay on release.
*Time ranges:
1s - 10s 10s
6s - 60s 1m
60s - 600s10m
DBB51 should not be
operated by pulses
<200ms.
115/230VAC
24 to 240VAC/DC
24VDC/24 to 240VAC
*10V
*500V
SPDT
5A @ 250VAC
NPN-PNP open
collector NO(1)
Under voltage
­monitoring relay for DC
battery circuits.
Measures own powesupply. Self-point adustable. Hysteresis adjustable.
Taken from input
Over current monitoring
relay. 1 Phase AC setpoint adjustable 2 wire
connection. Integral CT
with 12mm dia hole.
*Add CT range to order
Code. (1)100mA 40VDC
max
12-24VDC
DIGITAL SCHOOL TIMER
Electronic School Timer
No. of
channels
Code
AUTOMATION PRODUCTS
SDM-10/U
16
1
Time
Range
24hrs/
7 days
Total no. of
programmes
Working Minimum
Reserve Interval
50 on + 50 off
3 years
User friendly, and easy to program. Lesson times can
easily be added or changed. The controller has a real time
clock and calendar.
Adjustable ringing duration.
Width: 35mm (2 Module width)
Complete with protective flap.
1 sec.
Width in
DIN
Relay
Output
2
16A, C/O
Supply Voltage: 24V - 230VAC/DC
Relay output rated at 16A, AC1 rating.
Battery backup, preventing data loss during power failure.
LED illumination of the LCD display.
Able to back up programmed times for 10 years.
Seasonal and holiday programming available
Electronic School Control Box
Code
EW-01
The Electronic School Janitor is an assembled unit.
Used for controlling school utilizing the SDM-10.
It consists of:
• Over Voltage Protection
• Bell Controller (SDM-10)
• Electromagnetic Relay x 2
• Alarm Button
• Accoustic Alarm Indicator
• Short period selection button
DPM
Features:
Two ways of connecting directly to the school bell or
connecting to the existing installation instead of manually
ringing the bell.
• Easily programmable timetable.
• Real time clock.
• Adjustable ringing duration.
• Programmable alarm bells.
• Seasonal and holiday programming available