Sectional doors

Transcription

Sectional doors
Sectional doors
Technical data sheets
09 - 2007
Sectional Doors Technical data sheets
-2-
01/09/07
DITEC S.p.A
CONTENTS
Sectional doors with staved panels - PARIS, LISBON, BAY ......................................................................... 04
Sectional doors with cassette panels - ROME WIEN ..................................................................................... 06
Extruded aluminium sections - GOLD ALU .................................................................................................... 08
WINDOWS and GRID .........
12
PEDESTRIAN DOOR INSERTED ...................................................................................................................... 14
POWERED SYSTEMS ........
18
RL - RESIDENTIAL LIFTING .............................................................................................................................. 24
NL - NORMAL LIFTING ......
26
HL - HIGH LIFTING.............
28
VL - VERTICAL LIFTING ....
30
RLO - REDUCED LIFTING (outside pulleys) ................................................................................................... 32
RLB - REDUCED LIFTING (back springs)........................................................................................................ 32
IL - INCLINED LIFTING ......
34
HLIL - HIGH INCLINED LIFTING ....................................................................................................................... 36
BAY INDUSTRIAL DOOR ...
38
FITTING WITH TUBOLAR PIPE SPACER ......................................................................................................... 39
CURTAIN WEIGHT TABLE
40
Legend
PL
PH
SS
SD
HA
G
GM
GA
Horizontal passage way
Vertical passage way
Left post
Right post
Headroom height
Total horizontal guide size
Total horizontal guide size for manual door.
Total horizontal size for automatic door.
N.B. Refer to the dimensions shown in the price-list
All rights reserved
The details furnished have been drawn up and checked with the utmost care. We cannot however assume any
liability for any errors, omissions or approximations due to technical or graphic requirements.
Sectional Doors Technical data sheets
-3-
01/09/07
DITEC S.p.A
PANNELLI A DOGHE (PARIS, BERN, LISBON, BAY)
LIFTING NL
LIFTING NL,HL,VL,RLO,RLB,IL,HLIL,DI
LIFTING RL
Posizione pannello dal basso
PH
1780
1890
2060
2170
2280
2390
2500
2560
2670
2780
2890
3000
3110
3280
3390
3500
3610
3720
3890
4000
4110
4220
4330
4500
4610
4720
4830
4940
5110
5220
5330
5440
5550
5720
5830
5940
6050
6160
6330
6440
6550
6660
6770
6940
7000*
1
610
610
500
500
610
610
610
500
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
2
500
610
500
500
500
610
610
500
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
3
610
610
500
500
500
500
610
500
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
4
5
6
7
8
9
10
11
12
500
610
610
610
610
500
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
500
610
610
610
610
610
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
610
610
610
610
610
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
500
610
610
610
610
610
610
500
500
500
500
610
500
500
500
610
610
500
500
610
610
610
610
610
500
500
500
500
610
500
500
610
610
610
610
610
500
500
610
610
PH
1780
1890
2060
2170
2280
2390
2500
2560
2670
2780
2890
3000
3110
3280
3390
3500
3610
3720
3890
4000
4110
4220
4330
4500
4610
4720
4830
4940
5110
5220
5330
5440
5550
5720
5830
5940
6050
6160
6330
6440
6550
6660
6770
6940
7000*
* The last panel 610 mm tall is cut.
NOTE: PL minimum 1800
The panels position order can be modified (if the curtain hasn’t special accessories).
Thermal insulation coefficient
PARIS, LISBON, BAY: standard colours
External side
White
Blue
Silver
Green
Moor black
Internal side
Veined simil RAL 9003W
Veined simil RAL 5010W
Veined simil RAL 9006W
Veined simil RAL 6005W
Veined simil RAL 8014W
White
Embossed simil RAL 9003E
Value calculated with the door
installed (certified data)
k = 1.51W/m2k
BERN: standard colours
Teak
wood effect flat White
Embossed simil RAL 9003E
Morado
wood effect flat
Embossed simil RAL 9003E
Sectional Doors Technical data sheets
White
-4-
01/09/07
DITEC S.p.A
center
40
65
15
37
57
15
center
150
37
57
SINGLE SIDE
HINGE (PL<=5200)
65
DOUBLE SIDE
HINGE (PL>5200)
78
PAINTED ZINC-COATED
15/10 STEEL SIDE
CASING RAL 9003
INTERMEDIATE HINGE
(DRILLED PANEL STEP
=1000 mm CA)
SEAL BETWEEN PANELS
INTERNAL VIEW
SIDE HINGE
ON DRILLED SIDE CASINGS
(NON-DRILLED PANEL)
H
(*) PL > 7300 = 110
500
526
610
636
EXTERNAL VIEW
100
66
(*)
35
75
60
OMEGA
REINFORCING
PROFILE
SEAL WIT
SINGLE GLAZING
SEAL WITH
DOUBLE GLAZING
123
57
WALL INTERNAL SIDE
Omega reinforcing profile positioning
> 5000 PL 5500
> 5500 PL 6500
PL > 6500
On odd panels only
One on each panel
Two on each panel
With four panels
> 5000 PL 5500
With pedestrian door
Two reinpreing profiles
Two reinpreing profiles
Sectional Doors Technical data sheets
-5-
01/09/07
DITEC S.p.A
CASSETTE PANELS (ROME, WIEN)
Panel position from below
PH
1
2
3
1780
610
500
610
4
5
6
PH
1890
610
610
610
2060
500
500
500
500
2060
2170
500
500
500
610
2170
2280
610
500
500
610
2280
2390
610
610
500
610
2390
2500
610
610
610
610
2560
500
500
500
500
500
2560
2670
500
500
500
500
610
2670
2780
610
500
500
500
610
2780
2890
610
610
500
500
610
2890
3000
610
610
610
500
610
3000
3110
610
610
610
610
610
3280
610
500
500
500
500
1780
1890
2500
3110
3280
610
NOTE: PH < 2000 cut cassettes
PL
2600
2800
3200
3500
4000
4600
5000
B - N° of cassettes per line
3
4
4
5
5
6
7
IS - distances between cassettes ~ (±5)
255
150
225
145
230
185
170
NOTE: PL minimum 1800
PL < 2000 cut cassettes
PH
IS
PL
ROME: Standard colours
External side
White
Green
Moor black
Thermal insulation coefficient
Internal side
Veined simil RAL 9003W
Veined simil RAL 6005W
Veined simil RAL 8014W
White
Embossed simil RAL 9003E
WIEN: Standard colours
Teak
Wood effect veined
White
Embossed simil RAL 9003E
Morado
Wood effect veined
White
Embossed simil RAL 9003E
Sectional Doors Technical data sheets
-6-
Value calculated with the door
installed (certified data)
k = 1.51W/m2k
01/09/07
DITEC S.p.A
20 min
Start box
EXTERNAL VIEW
INTERNAL VIEW
347
35
526
500
Seal between panels
506
40
EXTERNAL VIEW
INTERNAL VIEW
347
636
35
610
Seal between panels
Sectional Doors Technical data sheets
506
-7-
01/09/07
DITEC S.p.A
GOLD ALU
3+3 glass fill-in
3+9+3 acrylic double glazing
Acrylic fill-in / Net / Grid
1
2
3
4
5
6
7
Panel positions from below
8
9
1
2
3
4
5
6
2060
GA/500 GA
GA
GA
GA/500 GA
GA
GA
2170
GA/500 GA
GA
GA
GA/500 GA
GA
GA
2280
GA/610 GA
GA
GA
GA/610 GA
GA
GA
2390
GA/610 GA
GA
GA
GA/610 GA
GA
GA
2500
GA/610 GA
GA
GA
GA/610 GA
GA
GA
2560
GA/500 GA
GA
GA
GA
GA/500 GA
GA
GA
GA
2670
GA/500 GA
GA
GA
GA
GA/500 GA
GA
GA
GA
2780
GA/610 GA
GA
GA
GA
GA/610 GA
GA
GA
GA
2890
GA/610 GA
GA
GA
GA
GA/610 GA
GA
GA
GA
3000
GA/610 GA
GA
GA
GA
GA/610 GA
GA
GA
GA
3110
GA/610 GA
GA
GA
GA
GA/610 GA
GA
GA
GA
3280
GA/610 GA
GA
GA
GA
GA
GA/610 GA
GA
GA
GA
GA
3390
GA/610 GA
GA
GA
GA
GA
GA/610 GA
GA
GA
GA
GA
3500
GA/610 GA
GA
GA
GA
GA
GA/610 GA
GA
GA
GA
GA
3610
GA/610 GA
GA
GA
GA
GA
GA/610 GA
GA
GA
GA
GA
3720
GA/610 GA
GA/610 GA
7
8
9
PH maximum for completely Gold Alu curtain
Panel positions from below
PH
GA
GA
GA
GA
GA
GA
GA
GA
3890
610
G1
G2
G3
G4
G5
610
610
G1
G2
G3
G4
G5
610
4000
610
G1
G2
G3
G4
G5
610
610
G1
G2
G3
G4
G5
610
4110
610
G1
G2
G3
G4
G5
610
610
G1
G2
G3
G4
G5
610
4220
610
G1
G2
G3
G4
G5
610
610
G1
G2
G3
G4
G5
610
4330
610
G1
G2
G3
G4
G5
610
610
G1
G2
G3
G4
G5
610
4500
610
G1
G2
G3
G4
G5
G6
610
610
G1
G2
G3
G4
G5
500
610
4610
610
G1
G2
G3
G4
G5
G6
610
610
G1
G2
G3
G4
G5
500
610
4720
610
G1
G2
G3
G4
G5
G6
610
610
G1
G2
G3
G4
G5
500
610
4830
610
G1
G2
G3
G4
G5
G6
610
610
G1
G2
G3
G4
G5
500
610
4940
610
G1
G2
G3
G4
G5
G6
610
610
G1
G2
G3
G4
G5
610
610
5110
610
G1
G2
G3
G4
G5
G6
G7
610
610
G1
G2
G3
G4
G5
500
500
610
5220
610
G1
G2
G3
G4
G5
G6
G7
610
610
G1
G2
G3
G4
G5
500
500
610
5330
610
G1
G2
G3
G4
G5
G6
G7
610
610
G1
G2
G3
G4
G5
500
500
610
5440
610
G1
G2
G3
G4
G5
G6
G7
610
610
G1
G2
G3
G4
G5
610
500
610
5550
610
G1
G2
G3
G4
G5
G6
G7
610
610
G1
G2
G3
G4
G5
610
610
610
PH/PL
3000
4000
5000
7000
PH/PL
3000
4000
5000
3720
GA
GA
1°
1°
3720
GA
1°
1°
4330
1° - A
1° - A
1° - A
1° - A
4330
1° - A
1° - A
1° - A
4940
1° - A
1° - A
1° - A
1° - A
4940
1° - A
1° - A
1° - A
5550
1° - A
1° - A
1° - A
1° - A
5550
1° - A
1° - A
1° - A
Legend:
Legend:
1°
1° - A
1°
1° - A
= only the lower panel is insulated, 500 / 610
= the lower and the upper panels are insulated, 500 /
610
GA
= the door can be made completely of Gold Alu panels
G1....G7 = GA sections or insulated panels, 500 / 610
Sectional Doors Technical data sheets
= only the lower panel is insulated, 500 / 610
= the lower and the upper panels are insulated, 500 /
610
GA
= the door can be made completely of Gold Alu panels
G1....G5 = GA sections or insulated panels, 500 / 610
-8-
01/09/07
DITEC S.p.A
Gold Alu acrylic / net / grid from G1 to G7
Gold Alu 3+3 glass / acrylic double glazing from G1 a G5
PH
L
PH
L
PL
L
L
PH
...
...
G1
1
1
G1
...
PH
...
...
G5
6
G7
8
7-8
PL
PL
PL
L
PL
NOTES
Acrylic / Net / Grid
3+3 glass
acrylic double glazing 3+9+3
PL ≤ 3000
No reinforcement
≤ 1500
≤ 1500
PL ≤ 4000
Omega elements in aluminium in the GA panels
≤ 1000
≤ 1000
PL ≤ 5000
Omega elements in aluminium in the GA panels
In the 500 / 610 panels close to the GA panels, the omega
element in galvanised steel
PL ≥ 5200 double side hinge.
≤ 1000
≤ 750
PL ≤ 7000
Omega elements in aluminium in the GA panels
In the 500 / 610 panels close to the GA panels, the omega
element in galvanised steel
PL ≥ 5200 double side hinge.
≤ 1000
Inserted pedestrian door
Acrylic fill-in / Net / Grid
PL
3+3 glass fill-in / acrylic double glazing
NOTES
PL
NOTES
PL ≤ 4000
DOIGA8, DOIGA, DOIGA (1) 12 - At centre position
PL ≤ 3000
DOIGA8, DOIGA, DOIGA 12 - At centre position
PL ≤ 5000
DOIGA8, DOIGA (1) - At centre position
PL ≤ 3500
DOIGA8, DOIGA - At centre position
(1) Variable dimension (self adjusting) following the Gold Alu frame sections in width.
Sectional Doors Technical data sheets
-9-
01/09/07
DITEC S.p.A
GOLD ALU
PL
FILLINGS
≤ 4000
≤ 5000
≤ 6000
≤ 7000
XGAM40T
XGAM50T
XGAM60T
XGAM70T
XGAM40S
XGAM50S
XGAM60S
XGAM70S
XGAV40T
XGAV50T
XGAV40S
XGAV50S
XGAM40C
XGAM50C
XGAR40V
XGAR50V
XGAR60V
GAR70V
XGAG40V
XGAG50V
3 mm transparent acrylic panel
3 mm pearl acrylic panel
Laminated 3+3 mm transparent glass
Laminated 3+3 mm pearl glass
Trasparent acrylic double glazing
Stretched 1.5 mm coated net 28x10
Ventilation grid with fixed inclined fins in anodised/coated
aluminium, 20 mm apart
NOTE: glass stop and natural anodised aluminium omega strengthening element
Table matching insulated panels to Gold Alu panels (simil RAL)
Insulated section
External side
White
Blue
Silver
Green
Moor black
Veined simil RAL 9003W
Veined simil RAL 5010W
Veined simil RAL 9006W
Veined simil RAL 6005W
Veined simil RAL 8014W
Internal side
White
Gold Alu section
Internal side
White
Blue
Anodised aluminium
Green
Moor black
simil RAL 9010
simil RAL 5010
Natural colour
simil RAL 6005
simil RAL 8014
Internal side
Embossed simil RAL 9003E
As external side
NOTE: colours other than those specified are not available for Gold Alu; so a door with Gold Alu section must has only the colours
and the twinning indicate on the table.
Sectional Doors Technical data sheets
- 10 -
01/09/07
DITEC S.p.A
See table p. 9
SECTION A-A ’
71
119
A
56
56
X
B
B’
71
X + 36
X = 500 610
A’
71
119
SECTION B-B’
119
SECTION C-C’
TOP
PROFILE
71
ACRYLIC PLATE 3 mm
LAMINATED GLASS 3+3
SECTION D-D’
Aluminium
reinforcing
profile
Double side hinge
Steel
reinforcing
profile
66
ACRYLIC DOUBLE
GLAZING
119
85
150
35
BOTTOM
PROFILE
Porta pedonale inserita
C
=
=
=
=
C’
=
=
PH
=
=
=
D
PL
D’
External view
Sectional Doors Technical data sheets
Internal view
- 11 -
01/09/07
DITEC S.p.A
OBLÒ and GRID
260
325
OBO1B - Black rectangular window in acrylic double glazing
425
490
Applicability (*)
PL (2)
N° max for
panel
1800 ÷ 2070
2070 ÷ 2700
2700 ÷ 3340
3340 ÷ 3970
3970 ÷ 4600
4600 ÷ 5000
5000 ÷ 5240
5240 ÷ 5500
2
3
4
5
6
7
7
8
1800 ÷ 2640
2640 ÷ 3460
3460 ÷ 4290
4290 ÷ 5000
5000 ÷ 7000
2
3
4
5
5
1800 ÷ 2590
2590 ÷ 3400
3400 ÷ 4200
4200 ÷ 5000
5000 ÷ 7000
2
3
4
5
5
1800 ÷ 2430
2430 ÷ 3180
3180 ÷ 3940
3940 ÷ 7000
2
3
4
5
•
1800 ÷ 2180
2180 ÷ 2840
2840 ÷ 3510
3510 ÷ 4180
4180 ÷ 5000
5000 ÷ 7000
2
3
4
5
6
6
•
1800 ÷ 1980
1980 ÷ 2580
2580 ÷ 3190
3190 ÷ 3790
3790 ÷ 7000
2
3
4
5
6
•
Notes
Paris
Bern
Rome
Wien
Lisbon
Bay
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1)
(1)
297
373
OBO2B - Black rectangular window in acrylic double glazing
•
(1)
604
680
267
343
OBO3B - Black oval porthole in acrylic double glazing
(1)
587
663
83
145
OBO4B - Black rectangular window in acrylic double glazing
548
610
272
360
WIW1, WIB1 - Al lacquered window with double glazing
437
525
(1)
56
95
GRI1B, GRI1W - Ventilation grid en PVC (3)
426
460
(*) On the last panel the applicability nust be evaluated by the eventual panel vertical cutting
(1) On 610 step panel
(2) Valid measurements for stave models (Paris, Lisbon), for cassette curtains refer to the indications on page 6: 1 porthole per cassette
(3) In case of GRI1 on the 1st panel the holes for the handle are not presented
Sectional Doors Technical data sheets
- 12 -
01/09/07
DITEC S.p.A
Paris / Bern / Lisbon / Bay
=
=
=
=
=
=
=
=
al centro della cassetta
5
=I
4
III
V
=
=
3
II
=
2
=
IV
=
al centro della cassetta
=
=
1
I
II
III
IV
V
I
III
V
Rome / Wien
at cassette centre
5
I
III
V
4
3
II
2
IV
at cassette centre
1
I
II
III
IV
V
I
Fastening
Frame colour
Fill-in
Illuminating
surfaces
OBO1B
Acrylic plate with double glazing
1100 cm2
OBO2B
Acrylic plate with double glazing
1790 cm2
•
OBO3B
Acrylic plate with double glazing
1490 cm2
•
OBO4B
Acrylic plate with double glazing
450 cm2
•
WIW1
3+3-9-3+3 double glazing
1180 cm2
•
WIB1
3+3-9-3+3 double glazing
1180 cm2
•
Model
Fill-in
Air opening
GRI1W
GRI1B
Model
Trip
III
Screw
White
•
Fastening
Trip
Plastic
•
•
•
•
•
•
•
•
Frame colour
Ventilation grid
175 cm2
•
•
Ventilation grid
175 cm2
•
Aluminium
•
•
White
- 13 -
Frame material
Black
•
Screw
Sectional Doors Technical data sheets
V
Black
•
Frame material
Plastic
Aluminium
•
•
•
01/09/07
DITEC S.p.A
PEDESTRIAN DOOR INSERTED
Model
Pedestrian door position (internal view)
Dimension L
Pusching at
Paris / Bern (1)
Lisbon (1)
DOI8R
Right
800
Right
•
•
DOI8L
Left
800
Left
•
•
DOI8C
Centre
800
Right
•
•
DOI12R
Right
1200
Right
•
•
DOI12L
Left
1200
Left
•
•
DOI12C
Centre
1200
Right
•
DOIGA
Centre
≤ 1000 (3)
Right
•
(2)
•
(2)
DOIGA 8
Centre
800
Right
•
(2)
•
(2)
DOIGA 12
Centre
1200
Right
•
(2)
•
(1) maximum size of sectional door PL ≤ 5000
(2) with Gold Alu section (see max. dimension at page 9)
(3) variabil dimensione following the Gold Alu frame division.
PH
H pedestrian door from floor
1800 ÷ 1895
1740
1900 ÷ 2160
PH - 134
2165 ÷ 2405
2040
2410 ÷ 2515
2060
2520 ÷ 2575
2230
2580 ÷ 2685
2340
2690 ÷ 2905
2040
2910 ÷ 3125
2060
3130 ÷ 3405
2040
3410 ÷ 3735
2060
3740 ÷ 3905
2040
3910 ÷ 5540
2060
NOTE: pedestrian door configurations other than those shown are also available on request. Please contact the our
technical sales office.
Sectional Doors Technical data sheets
- 14 -
01/09/07
DITEC S.p.A
External view
800 - 1200
> 120
_
1700
~
2030
H
~1050
~1090 con SOF
X
L
L
66
66
X=
210
PL = L-150
Left side door
push to left
Right side door
push to right
400
Centre door
=
400
Internal view
Sectional Doors Technical data sheets
X=
170
PL = L-100
=
Internal view
- 15 -
01/09/07
DITEC S.p.A
PEDESTRIAN DOOR INSERTED
INSERTION WINDOWS
With pedestrian door of 800, side
With pedestrian door of 800, centre
OBO1B
≤ 2640
2640 ÷ 3670
3670 ÷ 4700
4700 ÷ 5000
Max n°of
windows for
panel
2
3
4
OBO2B
≤ 2730
2730 ÷ 3860
3860 ÷ 5000
2
3
OBO3B
≤ 2720
2720 ÷ 3840
3840 ÷ 5000
2
3
OBO4B
≤ 2700
2700 ÷ 3790
3790 ÷ 4880
4880 ÷ 5000
2
3
4
•
•
≤ 2590
2590 ÷ 4170
4170 ÷ 5000
1
3
5
•
•
WIW1
≤ 2650
2650 ÷ 3700
3700 ÷ 4750
4750 ÷ 5000
2
3
4
•
•
≤ 2500
2500 ÷ 4000
4000 ÷ 5000
1
3
5
•
•
WIB1
≤ 2650
2650 ÷ 3700
3700 ÷ 4750
4750 ÷ 5000
2
3
4
•
•
≤ 2500
2500 ÷ 4000
4000 ÷ 5000
1
3
5
•
•
GRI1B
≤ 2620
2620 ÷ 3640
3640 ÷ 4660
4660 ÷ 5000
2
3
4
•
•
≤ 2440
2440 ÷ 3870
3870 ÷ 5000
1
3
5
•
•
GRI1W
≤ 2620
2620 ÷ 3640
3640 ÷ 4660
4660 ÷ 5000
2
3
4
•
•
≤ 2440
2440 ÷ 3870
3870 ÷ 5000
1
3
5
•
•
PL
Applicability
PL
Max n°of
windows for
panel
Paris Bern
Lisbon
•
•
≤ 2470
2470 ÷ 3930
3930 ÷ 5000
•
•
Lisbon
1
3
5
•
•
≤ 2660
2660 ÷ 4310
4310 ÷ 5000
1
3
5
•
•
•
≤ 2640
2640 ÷ 4280
4280 ÷ 5000
1
3
5
With pedestrian door of 1200, side
PL
Max n°of
windows for
panel
OBO1B
≤ 3240
3240 ÷ 4470
4470 ÷ 5000
OBO2B
Applicability
Paris Bern
•
With pedestrian door of 1200, side
Applicability
PL
Max n°of
windows for
panel
Paris Bern
Lisbon
2
3
•
•
≤ 3270
3270 ÷ 5000
≤ 3330
3330 ÷ 4660
4660 ÷ 5000
2
3
•
•
OBO3B
≤ 3320
3320 ÷ 4640
4640 ÷ 5000
2
3
OBO4B
≤ 3300
3300 ÷ 4590
4590 ÷ 5000
2
3
WIW1
≤ 3250
3250 ÷ 4500
4500 ÷ 5000
WIB1
Applicability
Paris Bern
Lisbon
1
3
•
•
≤ 3460
4660 ÷ 5000
1
3
•
•
•
≤ 3440
4440 ÷ 5000
1
3
•
•
≤ 3390
3390 ÷ 5000
1
3
•
•
2
3
•
•
≤ 3300
3300 ÷ 5000
1
3
•
•
≤ 3250
3250 ÷ 4500
4500 ÷ 5000
2
3
•
•
≤ 3300
3300 ÷ 5000
1
3
•
•
GRI1B
≤ 3220
3220 ÷ 4440
4440 ÷ 5000
2
3
•
•
≤ 3240
3240 ÷ 5000
1
3
•
•
GRI1W
≤ 3220
3220 ÷ 4440
4440 ÷ 5000
2
3
•
•
≤ 3240
3240 ÷ 5000
1
3
•
•
01/09/07
DITEC S.p.A
•
NOTE: windows on pedestrian door only from the 3rd panel upwards.
Sectional Doors Technical data sheets
- 16 -
Side door
=
=
Paris / Bern / Lisbon
=
≥ 400
=
=
=
=
=
External view
Centre door
Paris/ Bern / Lisbon
=
=
=
=
=
=
=
=
=
=
External view
Sectional Doors Technical data sheets
- 17 -
01/09/07
DITEC S.p.A
MOTORIZZAZIONI
Globe
GA
GA
PH / PL
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
PH ≤ 2280
PH > 2280
3420
4540
4750
5000
5250
5500
2060
2170
2280
2390
2500
2560
2670
2780
2890
3000
3110
3280
Globe 7
Globe 10
DOD 14 - 15
Manual
LSD
LSA
100
30
27
320
65
100
5
LSDR
LSAR
25.4 (1")
65
135
LSD - LSA
LSDR - LSAR
LSAR + SP3F
264
Power supply
Absorption
DOD 14
230 V 50 Hz
3A
DOD 15
400 V 50 Hz
1.2 A
Sectional Doors Technical data sheets
Torque
60 Nm
75 Nm
65 Nm
- 18 -
Shaft revs
22 RPM
32 RPM
Curtain
speed
Protection
rating
≤ 0,3 m/s
≤ 0,24 m/s
≤ 0,3 m/s
IP 54
IP 54
01/09/07
DITEC S.p.A
Powered version
(LSD)
Automatic version monophase
(LSA)
Automatic version triphase
(LSAR + SP3F)
DOD 14 / 50E
DOD 15 / 49E
DOD 14PS
Not available for BAY model
10 m
230 V
400 V 3F
1,5 m
230 V
DOD External vertical powered system
420
362
285
145
400 min
265
(1)
(1) Version RLO e RLB + 100 mm.
Sectional Doors Technical data sheets
- 19 -
01/09/07
DITEC S.p.A
DOD Transmission powered system
145
570
285
265
DOD Internal vertical powered system (only for lifting VL)
400
410
550
350
Horizontal external powered system
395
680
336
140
145
400 min
265
Sectional Doors Technical data sheets
- 20 -
01/09/07
DITEC S.p.A
DOD manual release
The release cable must be used only for maintenance by authorized technicians.
Minimum height of
2,5 m from floor
DOD SBC (manual motion chain version)
Catena di prolunga
Extension chain
DODLCG
H DOD
H DOD
DODLCG
≤
5000
No
≤
9000
Sì
DOD SBV, SBO (manual motion rod version)
H DOD ≤ 4,5 m
H DOD ≤ 7,5 m
H DOD ≤ 10,5 m
5
1
1
1
3
3
Legend for accessories
2
4
3
3
2
2
Sectional Doors Technical data sheets
- 21 -
1 - DOD SBV
Manual vertical release
2 - MN3
Push rod L 3000 mm
3 - DOD SBRIN
Gear motor release drive with rod
H DOD >4.5 m from the ground
4 - DOD SBP
Release extension H DOD >7.5 m
from the ground (max 10.5 m)
5 - DOD SBO
Manual horizontal release
01/09/07
DITEC S.p.A
GLOBE - accessories
Globe SB
LOX SB - external release
300
External view
Internal view
LOX 1 - internal/external lock
LOX 1
External view with cassette
External view
Internal view
LOX 1
290
300
Sectional Doors Technical data sheets
300
- 22 -
300
01/09/07
DITEC S.p.A
LIFTING
PL
PH
HA
min.
max.
min.
max.
min.
1800
5500
1800
3280
160
5570
420
SS (2) SD (2)
max.
G
Weight in kg.
min.
min.
min.
max.
100
100
Vedi tabella
pag.24
250
RL (residential)
HA
PH
NL (normal)
HA
1800
8000
500
1800
PH
150
7000
150
PH + 1060
510
700
HL (hight)
960
HA
1800
7000
1800
2860
5940
650
150
2860
PH
150
PH - HA + 1100
4460
575
VL (vertical)
4000
HA
1800
6000
1800
600
PH + 300
150
150
5940
PH
500
RLO (reduced-outside pulleys)
HA
1800
5500
1800
4500
285
200
200
PH + 1030
290
1800
5500
1800
4500
200
200
200
PH + 1330
290
5570
490
PH
RLB (riduced-back springs)
(1)
HA
PH
IL (inclined)
HA
1800
7000
500
1800
150
5940
PH
150
PH + 560
550
700
HLIL (HL + IL)
2860
HA
1800
7000
1800
5940
960
PH
650
150
150
PH - HA + 560
4460
575
2020
650
DI (double inclination) (1)
490
HA
1800
7000
1800
5940
150
550
PH
150
3150
575
(1) Only by special execution, ask to technical office.
(2) For motorized dimension see page 19-20.
Sectional Doors Technical data sheets
- 23 -
01/09/07
DITEC S.p.A
RL - RESIDENTIAL LIFTING
PL
Model
PH
HA
SS
SD
GM
Weight
min
max
min
max
min
min
min
max
Paris
1800
5500
1800
3280
160
100
100
250
Bern
1800
5500
1800
3280
160
100
100
Rome
1800
5000
1800
3280
160
100
100
250
Wien
1800
5000
1800
3280
160
100
100
250
PH
GM
PH ≤ 2280
2780
2280 ≤ PH ≤ 2500
3000
2500 ≤ PH ≤ 3000
3500
3000 ≤ PH ≤ 3280
3780
See table
250
For the automatic (GLOBE) version see page 18
SPRINGS
Number of manoeuvres for standard version: 15.000
Heavy usage supplement available on request: 25.000 - 50.000 - 100.000, only after technical office check.
GM
500
HA
485
240
300
PH
400
170
100
Maximum
size limit,
including
accessories
Limite massimo
ingombri,
accessori
inclusi
170
Sectional Doors Technical data sheets
- 24 -
01/09/07
DITEC S.p.A
HA
PH
180
HA
RL
485
500
GM
APPLICATION COMPENSATION ELEMENT
PLATE FOR
MOUNTING
CEILING
SAFETY
DEVICE
*
PH
160
12/10 ZINC-COATED
PLATE FALSE
HEADROOM
40
PH
* For false headroom H>160 use braket KPAM
A - A'
SS
SD
100
100x50x2
COMPENSATION COLUMN
A'
2
50
A
PL
OUT FROM DOORWAY
INDOOR WAY
70
B - B'
B
Sectional Doors Technical data sheets
B'
- 25 -
01/09/07
DITEC S.p.A
NL - NORMAL LIFTING
PL
PH
HA
SS (1)
SD (1)
G
Weight
min
max
min
max
min
min
min
min
max
LS- LSD- LSA- LSDR- LSAR
1800
7000
1800
5550
420
150
150
PH + 1060
500
LSAR + SP3F
1800
8000
1800
5550
420
150
150
PH + 1060
500
LS- LSD- LSA- LSDR- LSAR
1800
7000
1800
5550
510
150
150
PH + 1060
750
LSAR + SP3F
1800
8000
1800
7000
510
150
150
PH + 1060
750
(1) For motorized version see overall dimensions on page 19-20
For manual version only G = PH + 500
SPRINGS
Number of manoeuvres for standard version: 20.000
Heavy usage supplement available on request: 25.000 - 50.000 - 100.000, only after technical office check.
G
= (*)
= (*)
1000
HA
A
1500
(*) Eventuale
calata aggiuntiva
Eventual additional
ceiling bracket
160
585
A (mm)
420
310
510
400
PH
HA (mm)
200
150
Limite massimo
ingombri,
accessori
inclusi
Maximum
size limit,
including
accessories
200
Sectional Doors Technical data sheets
- 26 -
01/09/07
DITEC S.p.A
HA
PH
B’
246 – 5
192 – 5
HA
B
CTB ANTI-JUMPING KIT
G
B - B’
420
PH
CEILING FIXING
BRACKET
A
A’
FALSE HEADROOM
WITH INSULATED STAVE PANEL
APPLICATION ELEMENT IN PANEL
A - A’
SS
PL
SD
150
150x50x2 COMPENSATION
COLUMN
50
167
2
OUT FROM DOORWAY
INDOOR WAY
70
Sectional Doors Technical data sheets
- 27 -
01/09/07
DITEC S.p.A
NL
HL - HIGH LIFTING
PL
PH
HA
SS (1)
SD (1)
G
Weight
min
max
min
max
min
max
min
min
min
max
LS- LSD- LSA- LSDR- LSAR
1800
7000
1800
5930
960
2860
150
150
PH - HA + 1100
650
LS- LSDR- LSAR
1800
7000
1800
5930
2860
4460
150
150
PH - HA + 1100
575
(1) For motorized version see overall dimensions on page 19-20
SPRINGS
Number of manoeuvres for standard version: 20.000
Heavy usage supplement available on request: 25.000 - 50.000 - 100.000, only after technical office check.
G
= (*)
= (*)
1000
HA
400
1500
(*) Eventuale
calata aggiuntiva
Eventual additional
ceiling bracket
560
690
PH
245
200
150
Maximum
size limit,
including
accessories
Limite
massimo
ingombri,
accessori
inclusi
200
Sectional Doors Technical data sheets
- 28 -
01/09/07
DITEC S.p.A
HA
PH
HL
300 – 60
B
B’
REAR
SHOCK ABSORBER
HA
G
B - B’
CEILING FIXING
BRACKET
A - A’
A’
SS
PL
PH
A
SD
150
150x50x2
COMPENSATION COLUMN
50
2
OUT FROM DOORWAY
INDOOR WAY
70
For PL > 4000 and dark colours, verify fitting spacers as per page 39
Sectional Doors Technical data sheets
- 29 -
01/09/07
DITEC S.p.A
VL - VERTICAL LIFTING
PL
560
min
LS- LSD- LSA- LSDR- LSAR 1800
PH
HA
SS (1) SD (1) Weight
max
min
max
min
min
min
max
6000
1800
3700
PH + 300
150
150
600
LS- LSDR- LSAR
1800
6000
1800
4000
PH + 300
150
150
600
LS- LSDR- LSAR
1800
6000
1800
5940
PH + 300
150
150
500
(1) For motorized version see overall dimensions on page 19-20
HA
SPRINGS
Number of manoeuvres for standard version: 20.000
Heavy usage supplement available on request: 25.000 - 50.000 - 100.000, only after
technical office check.
PH
240
200
150
Maximum
size limit,
including
accessories
Limite massimo
ingombri,
accessori
inclusi
200
Sectional Doors Technical data sheets
- 30 -
01/09/07
DITEC S.p.A
HA
PH
REAR
SHOCK ABSORBER
HA
END PROFILE AT C
FOR FITTING
SHOCK ABSORBER
A’
SS
PL
SD
150x50x2
COMPENSATION COLUMN
150
2
50
PH
A
OUT FROM DOORWAY
INDOOR WAY
70
For PL > 4000 and dark colours, verify fitting spacers as per page 39
Sectional Doors Technical data sheets
- 31 -
01/09/07
DITEC S.p.A
VL
RLO / RLB - REDUCED LIFTING
RLO
HA
SS
SD
G
Weight
min
PL
max
min
PH
max
min
min
min
min
max
1800
5500
1800
4500
285
200
200
PH + 1030
290
G
Weight
RLB (only by special execution on request to technical commercial office)
PL
PH
HA
SS (1)
SD (1)
min
max
min
max
min
min
min
min
max
1800
5500
1800
4500
200
200
200
PH + 1330
290
(1) For motorized version see overall dimensions on page 19-20
SPRINGS
Number of manoeuvres for standard version: 20.000
Heavy usage supplement available on request: 25.000 - 50.000 - 100.000, only after technical office check.
G
= (*)
= (*)
1000
HA
325
1500
Eventual additional
ceiling bracket
(*) Eventuale
calata aggiuntiva
222
600
PH
RLB (back
(mollesprings)
posteriori)
200
200
300
Limite massimo
ingombri,
accessori
inclusi
Maximum
size limit,
including
accessories
200
Sectional Doors Technical data sheets
- 32 -
01/09/07
DITEC S.p.A
HA
PH
RLO
HA
RLO VERSION SLIDING
35
65
G
HA
PH
B
RLB
RLB SLIDING VERSION
B’
G
PH
B - B’
A
A’
CEILING FIXING
BRACKET
SS
PL
SD
200x50x2
COMPENSATION COLUMN
A - A’
200
50
2
OUT FROM DOORWAY
INDOOR WAY
70
Sectional Doors Technical data sheets
- 33 -
01/09/07
DITEC S.p.A
IL - INCLINED LIFTING
PL
PH
HA
SS
SD
G
α
Weight
min
max
min
max
min
min
min
min
max
max
1800
7000
1800
5590
490
150
150
PH + 560
45°
500
1800
7000
1800
5930
550
150
150
PH + 560
45°
700
00
10
0
46
*)
=(
G
*)
=(
00
15
HA
Eventualeadditional
calata aggiuntiva
(*) Eventual
ceiling bracket
160
490
PH
255
200
100
Limite
massimo
ingombri,
accessori
inclusi
Maximum
size limit,
including
accessories
200
Sectional Doors Technical data sheets
- 34 -
01/09/07
DITEC S.p.A
HA
PH
B
HA
B’
G
α
B - B’
PH
CEILING FIXING
BRACKET
A - A’
A
A’
SS
PL
SD
150
150x50x2
COMPENSATION COLUMN
50
2
OUT FROM DOORWAY
167
Sectional Doors Technical data sheets
INDOOR WAY
70
- 35 -
01/09/07
DITEC S.p.A
IL
IL
HLIL - HIGH INCLINED LIFTING
PL
PH
HA
SS
SD
G
α
Weight
min
max
min
max
min
max
min
min
min
max
max
1800
7000
1800
5940
960
4460
150
150
PH - HA + 560
45°
650
INCLINED LIFTING
Inclination angle (α) linked to h (misured at 1m from α)
α
h
1m
α
h (mm)
α
h (mm)
α
h (mm)
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
11°
12°
13°
14°
15°
18
35
52
70
88
104
123
141
158
176
194
213
231
249
268
16°
17°
18°
19°
20°
21°
22°
23°
24°
25°
26°
27°
28°
29°
30°
287
306
325
344
364
384
404
425
445
466
488
510
532
554
577
31°
32°
33°
34°
35°
36°
37°
38°
39°
40°
41°
42°
43°
44°
45°
600
625
650
675
700
726
754
780
810
840
868
900
932
965
1000
Sectional Doors Technical data sheets
- 36 -
01/09/07
DITEC S.p.A
HA
PH
B
B’
G
HA
α
B - B’
CEILING FIXING
BRACKET
A - A’
A
A’
SS
PL
SD
150
2
50
PH
150x50x2
COMPENSATION COLUMN
OUT FROM DOORWAY
INDOOR WAY
70
For PL > 4000 and dark colours, verify fitting spacers as per page 39
Sectional Doors Technical data sheets
- 37 -
01/09/07
DITEC S.p.A
HL
IL
INDUSTRIAL BAY DOOR
SLINDING
LS- LSD- LSDR
PL
PH
HA
min
max
min
max
VL
1800
3100
2780
3110
HL
1800
3100
2780
3110
min
SS (1)
max
≥ PH + 300
960
2860
SD (1)
G
min
min
min
150
150
150
150
PH - HA + 1100
(1) For motorized version see overall dimensions on page 19-20
BAY optional template
For quotes and drowings please refer to HL - HIGHT LIFTING page 28 or VL - VERTICAL LIFTING page 30
Per quote e disegni far riferimento a HL - SCORRIMENTO ALTO pg.28 o VL - SCORRIMENTO VERTICALE pg.30
Sectional Doors Technical data sheets
- 38 -
01/09/07
DITEC S.p.A
FITTING WITH TUBOLAR PIPE SPACER
HA
HA
PH
HL
PH
HA
VL
PH
Spacing accessories to be used on doors with PL > 4000 and
standard colours RAL 8014, RAL 6005 e RAL 5010, and on all dark
no-standard colours .
���
��
���
Cod.S4560B25
�������
��
��
Closing detail
Sectional Doors Technical data sheets
- 39 -
01/09/07
DITEC S.p.A
HL
IL
CURTAIN WEIGHTS TABLE (kg)
Only for blind curtains with no portholes or doors
PH / PL
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
4500
4750
1560
46
51
56
61
66
71
75
80
85
90
95
100
105
1670
48
53
58
64
69
74
79
84
89
94
100
105
110
1780
50
56
61
67
72
77
83
88
93
99
104
110
115
1890
52
58
64
69
75
81
86
92
98
103
109
115
120
2060
59
65
72
78
85
91
97
104
110
117
123
130
136
2170
61
68
74
81
88
94
101
108
114
121
127
134
141
2280
63
70
77
84
91
98
104
112
118
125
132
139
146
2390
65
72
79
87
94
101
108
116
123
130
137
144
151
2500
67
75
82
90
97
104
112
119
127
134
141
149
156
2560
72
80
88
96
104
111
119
128
135
143
151
159
167
2670
74
82
90
99
107
115
123
131
139
147
155
164
172
2780
76
84
93
102
110
118
126
135
143
152
160
169
177
2890
78
87
95
104
113
121
130
139
148
156
165
174
182
3000
80
89
98
107
116
125
134
143
152
160
169
179
187
3110
82
91
100
110
119
128
137
147
156
165
174
183
192
3280
89
99
109
119
129
139
148
159
168
178
188
198
208
3390
91
101
111
122
132
142
152
163
173
183
193
203
213
3500
93
103
114
125
135
145
155
166
177
187
197
208
218
3610
95
106
116
127
138
149
159
170
181
191
202
213
224
3720
97
108
119
130
141
152
163
174
185
196
206
218
229
3890
104
115
127
139
151
162
174
186
198
209
221
233
244
4000
106
118
130
142
154
166
177
190
202
213
225
238
250
4110
108
120
132
145
157
169
181
194
206
218
230
243
255
4220
110
122
135
148
160
172
185
198
210
222
234
247
260
4330
112
125
137
151
163
176
188
201
214
226
239
252
265
4500
119
132
145
160
173
186
199
213
227
240
253
267
281
4610
121
134
148
162
176
189
203
217
231
244
258
272
286
4720
123
137
151
165
179
193
206
221
235
249
262
277
291
4830
125
139
153
168
182
196
210
225
239
253
267
282
296
4940
127
141
156
171
185
199
214
229
243
257
272
287
301
5110
134
149
164
180
195
210
225
241
256
271
286
302
317
5220
136
151
166
183
198
213
228
245
260
275
290
307
322
5330
138
153
169
185
201
216
232
248
264
279
295
311
327
5440
140
156
171
188
204
220
236
252
268
284
300
316
332
5550
142
158
174
191
207
223
239
256
272
288
304
321
337
5720
149
165
182
200
217
234
250
268
285
302
318
336
353
5830
151
168
185
203
220
237
254
272
289
306
323
341
358
5940
153
170
187
206
223
240
257
276
293
310
328
346
363
6050
155
172
190
209
226
244
261
280
297
315
332
351
368
6160
157
175
192
211
229
247
265
284
301
319
337
356
373
6330
164
182
201
220
239
257
276
296
314
332
351
371
389
6440
166
184
203
223
242
261
279
299
318
337
355
376
394
6550
168
187
206
226
245
264
283
303
322
341
360
380
399
6660
170
189
208
229
248
267
286
307
326
345
365
385
404
6770
172
191
211
232
251
271
290
311
330
350
369
390
410
6940
177
197
217
239
259
279
299
321
341
361
382
403
423
7000
178
198
218
240
260
280
300
322
342
362
383
404
424
Sectional Doors Technical data sheets
- 40 -
01/09/07
DITEC S.p.A
5000
5250
5500
5750
6000
6250
6500
6750
7000
7250
7500
7750
8000
PH / PL
110
131
137
149
155
160
166
194
201
206
265
273
281
1560
115
137
143
155
161
167
173
202
208
214
273
281
290
1670
120
143
149
161
167
174
180
209
216
222
281
290
298
1780
126
149
155
168
174
180
187
216
223
230
289
298
307
1890
142
173
181
194
202
209
217
255
263
270
348
359
370
2060
148
179
187
200
208
216
224
262
271
278
356
367
378
2170
153
185
193
207
215
223
231
269
278
286
364
375
387
2280
158
190
199
213
221
229
238
276
286
293
372
384
395
2390
164
196
204
219
228
236
245
283
293
301
380
392
404
2500
175
209
218
240
249
258
268
315
325
334
431
445
459
2560
180
215
224
246
255
265
275
322
333
342
439
453
467
2670
185
220
230
252
262
271
282
329
340
350
447
462
476
2780
191
226
236
258
268
278
289
336
348
358
455
470
484
2890
196
232
242
264
275
285
296
344
355
365
463
478
493
3000
202
238
248
271
281
292
303
351
363
373
471
486
501
3110
218
262
274
297
309
320
333
389
403
414
531
547
564
3280
223
268
280
304
315
327
339
396
410
421
539
556
573
3390
229
273
286
310
322
334
346
404
417
429
547
564
581
3500
234
279
292
316
328
340
353
411
425
437
555
572
590
3610
239
285
297
322
335
347
360
418
432
445
563
580
598
3720
256
304
317
349
362
376
390
456
472
485
622
641
661
3890
261
309
323
355
369
383
397
464
480
493
630
650
670
4000
267
315
329
361
375
389
404
471
487
501
638
658
678
4110
272
321
335
368
382
396
411
478
495
508
646
666
687
4220
277
326
341
374
388
403
418
485
502
516
654
674
695
4330
294
351
367
400
416
432
448
524
542
557
713
736
758
4500
299
357
373
407
422
438
455
531
549
565
721
744
767
4610
305
362
379
413
429
445
462
538
557
573
729
752
775
4720
310
368
384
419
435
452
469
545
564
580
737
761
784
4830
315
374
390
425
442
458
476
553
572
588
745
769
792
4940
332
393
410
452
470
487
506
591
611
629
804
830
855
5110
337
398
416
458
476
494
513
598
619
636
812
838
864
5220
342
404
422
464
482
501
520
606
626
644
820
846
872
5330
348
410
428
471
489
507
527
613
634
652
828
855
881
5440
353
415
434
477
495
514
534
620
641
660
836
863
889
5550
370
440
460
504
523
543
564
658
681
700
896
924
952
5720
375
446
466
510
530
549
571
666
689
708
904
932
961
5830
380
451
472
516
536
556
578
673
696
716
912
941
969
5940
386
457
477
522
543
563
585
680
704
723
920
949
978
6050
391
463
483
528
549
570
592
687
711
731
928
957
986
6160
408
482
503
555
577
598
621
726
751
772
987
1018
1050
6330
413
487
509
561
583
605
628
733
758
780
995
1027
1058
6440
418
493
515
568
590
612
635
740
766
788
1003
1035
1067
6550
424
499
521
574
596
618
642
747
773
795
1011
1043
1075
6660
429
504
527
580
603
625
649
755
781
803
1019
1051
1084
6770
444
525
548
602
626
650
675
789
816
843
1078
1112
1146
6940
445
526
549
603
627
651
676
790
817
844
1079
1113
1147
7000
Sectional Doors Technical data sheets
- 41 -
01/09/07
DITEC S.p.A
Technical data sheets 09 - 2007
Sectional doors
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - [email protected]
DITEC BELGIUM
DITEC DEUTSCHLAND
DITEC FRANCE
DITEC SVIZZERA
DITEC AMERICA
DITEC CHINA
DITEC ESPAÑOLA
LOKEREN
OBERURSEL
PALAISEAU
BALERNA
ORLANDO-FLORIDA-USA
SHANGHAI
BARCELONA
Tel. +32 9 3560051
Tel. +49 6171914150
Tel. +33 1 64532860
Tel. +41 91 6463339
Tel. +1 407 8880699
Tel. +86 21 62363863
Tel. +34 937958399
Fax +32 9 3560052
Fax +49 61719141555
Fax +33 1 64532861
Fax +41 91 6466127
Fax +1 407 8882237
Fax +86 21 62363863
Fax +34 937959026
ISO 9001