electrolysis hair remo

Transcription

electrolysis hair remo
8
2
9
CONDUCT IV E G E L
1
0
Fault/Cause
remedy
Amber treatment
light does not
stay/comeon
and console
bleeps.
Good contact
with the hair
is not being
maintained or
your finger is not
touching tweezer
button.
Check tweezers
are connected
The contact
with the hair or
tweezer button
has been lost.
If the contact is not
re-established
within three
seconds the
treatment timer will
assume you have
moved onto a new
hair and restart
the treatment from
the beginning.
Ensure you are
using gel.
Grasp hair at
skin level.
instructions
7
Problem
HAIR REMOVER ™
6
TRO uBLEsHO O TING
ELECTROLYSIS
YO U R E L E C T R O LY S I S
H A I R R E M OV E R
5
4
B AT T ER Y 9V P P 3
© The Dezac Group
professional range
BODY CARE
3
1. Console
6. Wand output socket
2. PowerON/OFFbutton
7. Power adapter socket
!
(optional extra available
from the Customer Careline)
3. Treatment indicator
(AMBER)
8. Tweezer Socket
4. Control dial
9. Tweezers
5. Treatment complete
indicator(GREEN)
10. Conductive gel
11.9VPP3Battery
The amber light
has gone out and
the console is
bleeping.
Grasp hair
at skin level.
The console is
bleeping and the
power light is
flashing.
Console left on and not used.
Turn the
console off.
Console is
bleeping
constantly.
Low Battery.
Replace battery.
The hair is
difficult to
remove.
More than a
single treatment
is required to kill
this hair.
If there is a lot
of resistance
an additional
treatment or longer
treatment time of
the same hair
may be required
Hair regrows.
It is not always
possible to kill
all of the papilla
cells in a single
treatment.
Repeat the
treatment when the
hair grows back.
© The Dezac Group
T I PS
• TheElectrolysisHairRemoverwillnotoperateifitcannot
detect the conductive gel.
• IfthepowerON/OFFbuttonisflashingthisindicatesthe
battery power is low and it needs replacing.
• Alwaysusethecorrecttypeofbattery(9VPP3).
The use of a good quality, leak-proof alkaline battery
is recommended.
• Iftheunitisleftunusedforalongperiodoftime,remove
the battery or unplug from the mains.
Redness of skin
after treatment.
Use a longer
treatment time.
This is quite
normal, you may
wish to apply an
antiseptic cream,
however the
redness should
fade within one
or two hours.
• TheElectrolysisHairRemovermayalsobeusedwitha
power adapter, which plugs into the adapter socket on
the side. To order please call the Customer Careline.
Using micro current technology the Electrolysis Hair Remover
destroys the hair root and papilla to prevent future hair growth.
The micro current changes the pH in the hair follicle to alkaline
which then starts to attack the hair root and papilla cells (it is
these cells which are responsible for hair growth). This action
continues for sometime after the treatment is complete and
the hair has been removed.
It is not always possible to kill all of the papilla cells in a single
treatment and in these situations the hair may regrow. If it does
regrow it is generally much finer and lighter than previously.
Successive treatments will kill the papilla cells giving a
permanent result. You may use your normal epilation
methods in between treatments.
© The Dezac Group
G E N E R A L C A R E
• Donotimmersetheconsoleortweezersinwater.
Treatment light
on continuously.
Contact is being
maintained
even when the
tweezers are not
in use.
Clean tweezers
with a damp
cloth thoroughly,
removing all traces
of conductive gel.
• Toenhancethelifetimeofyourtweezerskeepthem
on the console unit and do not use them for any other
purpose than intended.
• Afteruse,wipethetweezerscleanwithaslightlydamp
cloth, the console unit can also be wiped over.
Rio, Dezac and Electrolysis Hair Remover™
are trademarks of The Dezac Group Ltd
© The Dezac Group Ltd 2012
PO Box 17, Cheltenham Spa, England GL53 7ET
www.riobeauty.com
1-IN-CNHR2-UK / 1.1
The destruction of the hair root cells continues for some
time after the treatment has finished. It makes no difference
whether you remove the hair immediately or not.
If there is a particularly stubborn hair, an additional treatment
or longer treatment time may be required.
As with all hair removal treatments it is recommended that
the area you have treated is washed with cool water and a
mild antiseptic cream applied.
warnings
•Read all instructions thoroughly and
retain for future reference.
•This appliance is not intended for use
by persons with reduced physical,
sensory or mental capabilities, or
lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the
appliance by a person responsible for
their safety.
fitting the batter y
STEP 5
5
Gel
STEP 1
1
Only apply a gentle pressure on the
tweezers, do NOT press the button fully
(see step 7). You must use a bare finger on
the tweezer button. Do not wear a glove.
Release the clip to open the battery cover.
B AT T E R Y 9 V P P 3
6
STEP 2
2
Take hold of the hair at the point where it
meets the skin.
STEP 6
© The Dezac Group
•Do not treat the following areas:
pimples, warts, hair on black spots
or moles, dark freckles, skin disease,
burns, eczema, or eyelashes.
Connect a PP3 alkaline battery and
replace battery cover ensuring it is shut
firmly in place.
B AT T E R Y 9 V P P 3
HA ir R E moval
The amber treatment light will start flashing,
indicating the treatment is in progress.
If the amber light does not come on, check
the tweezers are plugged in and that you
are making a good contact with the hair at
the point where it meets the skin.
7
When the treatment is complete you will
hear a short bleep and the green ‘treatment
complete indicator’ will illuminate. The
hair can now be removed by increasing
the pressure on the tweezer button to
pluck the hair out of the hair follicle.
(The unit will then automatically reset itself
to start again).
STEP 1
1
Wash area to be treated with warm water
and mild soap. This will remove any
excess oil from the skin.
2
STEP 2
Check the speed control is on minimum
and turn the unit on with the On/Off button.
STEP 7
© The Dezac Group
The On/Off light will illuminate.
CONDUCTIVE G EL
•Not for use on or by children under 14
years old. Not for use on or by children
between 14 and 17 years old without
parental supervision.
STEP 3
3
•Do not use after drinking alcohol or if
you are feeling unwell or fatigued.
professional range
BODY CARE
B AT T E R Y 9 V P P 3
Turn the Control dial to suit the type of hair
being treated. The treatment time varies
between five and thirty seconds depending
on the setting (see hair treatment chart).
H A I R TREATME N T C H ART
•Please remove all jewellery in the
vicinity of the treatment area before use.
•There are no user serviceable parts
inside the unit or wand. Do NOT
dissemble or repair. If you have any
problems using the product, contact
our Customer Care Department.
Hair Type
Dial Setting
Treatment Time
Fine hair
eg lip
2-5
5 - 15 seconds
8
STEP 8
If contact with the hair is broken
during treatment the amber treatment
light will go out and the unit will bleep
three times. If the contact is not
re-established within three seconds the
treatment timer will assume you have
moved onto a fresh hair and will restart the
treatment programme.
C ustomer C are
If you have any questions, please call our Customer
Careline on: +44 (0) 1242 702345 or email us at:
[email protected]
To register your two year guarantee
www.riobeauty.co.uk/warranty.html
online
visit:
© The Dezac Group
4
Medium hair
eg eyebrow
6-9
15 - 25 seconds
Thick hair
eg bikini line
10 - 13
25 - 30 seconds
STEP 4
Apply a small amount of conductive gel to
the hairs which are to be treated OR put a
blob of gel on the skin, into which you can
dip the tweezers before taking hold of the
individual hair.
D isposal
The Waste of Electrical and Electronic Equipment
(WEEE) Directive (2002/96/EC) has been put in
place to recycle products using best available
recovery and recycling techniques to minimise the
impact on the environment, treat any hazardous
substances and avoid the increasing landfill.
The product is classed as Electrical or Electronic equipment
so please ensure that at the end of the life of this product
it is disposed of in the correct manner in accordance with
local authority requirements. It must NOT be disposed of with
household waste.