Mr. Kye-Won Park/ FILK(KFPA) [email protected]/ kwpark

Transcription

Mr. Kye-Won Park/ FILK(KFPA) [email protected]/ kwpark
Mr. Kye-Won Park/ FILK(KFPA)
[email protected]/
[email protected]
Nov. 2015
1
Façade fire accidents in S. Korea
창원
화재
Hotel
fire극장
in Seoul
(1971)
Multiplex fire in
High rise office fire in Seoul
ChangWon (2007)
(2008)
Residential tall
building fire in
Busan (2010)
• High-rise buildings with combustible exterior materials
• Rapid fire-spread risk from the façade fire
• However, No practical regulation and test method on façade fire
in Korea
• From the result of ISO 13785-2’s experiments, some issues come
out for revision
2
Status on revision proposal
Nov. 2013 : ISO TC92 SC1, Delft (* ISO 13785-2 Systematic Review)
- Comments from Korea, Japan for revision
April, 2014 : ISO TC92 SC1, Lund
- presentation on inputdata of ISO 13785-2 from Korea, Japan
Sep. 23rd, 2014 : Domestic PWI project’s approval from Korea government
Oct. 9th, 2014 : ISO TC92 SC1 – PWIP introduction
Nov. 12th, 2014 : Comparison tests in TUS and KICT for calibration method3
March. 31th, 2015 : Comparison tests in TUS and KICT for calibration method
Aug. 24th, 2015 : Calibration test in PAVUS of Czech republic
3
 Due to frequent fire cases in building facade over years, preventing
these facade fire is very important issue in Korea. Therefore,
technical issues(ig. test standard, assessment classification, and
measurement devices) concerning the façade fire of building are
being focused on. Furthermore, internationally there is no common
classification for assessment of façade fire and the test method over
countries. In conclusion, KFPA is trying to make the more refined
revision of the international standard (ISO 13785-2, façade fire test
method) and to develop the new criteria(classification). For this
issue, We would like to have the collaborating research institute in
European countires and, KFPA took place to make the related
proposal to ISO TC92 (International standard organization for fire
safety) for international contribution.
4
5
Test in PAVUS lab.
[2015. 08]
 Calibration test
 Several participant countries in Europe
6
7
Contents to be revised
8
Project proposal
We'd like to have the cooperation research institute for developing the
classification of the facade test's results to be available as the international
contribution.
We'd like to have the cooperation research institute for developing the
ISO facade test standard(ISO 13785-2) to be practically revised and for
making the related experiments.
We'd like to have the cooperation research institute for developing the
reasonalbe measument devices(ig. temperature measurement) to check the
assessment of face fire test.
9
KFPA (Korean Fire Protection Association) ?
10
KFPA (Korean Fire Protection Association) ?
11
FILK (Fire Insurers Lab. of Korea) ?
12
FILK (Fire Insurers Lab. of Korea) ?
13
FILK (Fire Insurers Lab. of Korea) ?
14
FILK (Fire Insurers Lab. of Korea) ?
15
16