Compact units field test - IEA Heat Pump Programme
Transcription
Compact units field test - IEA Heat Pump Programme
Evaluation of system performance by field test results Bernd Hafner Viessmann Werke, Allendorf (Eder) IEA Annex 28 Las Vegas 2005 Page 1 Vitotres 343 Technical Data Dimensions 200 x 60 x 68 cm DHW storage tank 250 l Prepared for solar collectors Ventilation heat recovery Air flow rate 70 to 250 m³/h Exhaust air heat-pump 1,5 kW with additional ambient air Electric heater 6 kW Hydraulic heating circuit Active cooling IEA Annex 28 Las Vegas 2005 Page 2 Passive House Field test Vitotres 343 Herzhausen Lightweight construction Surface 180 m² Volume 450 m³ Ground heat exchanger 2 x 30 m Heating demand 14,1 kWh/m² Vacuum tube collector 3 m² IEA Annex 28 Las Vegas 2005 Page 3 Passive House Field test Vitotres 343; Giessen Standard construction Surface 70 to 120 m² per flat Flat plate solar collector (approx. 10 m²) for 3 flats Heating demand 15 kWh/m² IEA Annex 28 Las Vegas 2005 Page 4 Energy consumption for house heating and hot water Energy in kWh/(m²a) 40 30 20 Energy delivered by compact unit Giessen 2 Herzhausen PHPP 10 Preliminary results 0 IEA Annex 28 Las Vegas 2005 Page 5 Seasonal Performance of HP 3,5 Evaluation without heat recovery Seasonal Performance Factor 3 2,5 2 1,5 Giessen 2 Herzhausen 1 Preliminary results 0,5 0 IEA Annex 28 Las Vegas 2005 Page 6 Electric consumption Herzhausen Giessen 2 9,5% 11,8% 1,3% 2,7% 9,1% 16,4% internal pump solar pump el. heater heat pump internal pump solar pump el. heater heat pump 69,1% 80,1% Preliminary results IEA Annex 28 Las Vegas 2005 Page 7 Heat delivered Giessen 2 Herzhausen 8,8% 7,9% 28,6% solar el. heater heat pump solar el. heater heat pump 3,1% 68,3% 83,3% Preliminary results IEA Annex 28 Las Vegas 2005 Page 8 Conclusion and Outlook • Data show a good behaviour of the system • Hydraulic scheme applicable for small systems with fsolar= 50 % • Control strategy applicable for other solar systems IEA Annex 28 Las Vegas 2005 Page 9