FIREGUARD 20, 60, 90, 180 FIREGUARD COLOR - Won-Door
Transcription
FIREGUARD 20, 60, 90, 180 FIREGUARD COLOR - Won-Door
FIREGUARD COLOR CHART Standard Color FIREGUARD 20, 60, 90, 180 #55 Platinum Optional Colors Available at Additional Cost #63 Sandalwood #53 Rose #62 Nile #77 Almond #64 Colonial Blue #33 Toast FIRE DOOR SELECTION GUIDE This guide will assist the specifier in selecting the most appropriate assembly and related options based on: 1. Fire rating required. 2. Special requirements for access control/security. FIRE RATINGS: 1. 2. 3. Won-Door FireGuard is listed as a fire-rated door (NFPA 252) with ratings up to 3 hours. Door Model Fire Rating Won-Door FireGuard 20 20 Minutes Won-Door FireGuard 60 1 Hour Won-Door FireGuard 90 1 1/2 Hours Won-Door FireGuard 180 3 Hours Won-Door FireGuard is also listed as a 450° temperature rise door (NFPA 252) with a 1 1/2 hour rating for use in stairwell enclosure applications Door Model Fire Rating Won-Door FireGuard 90TR 1 1/2 Hour Temperature Rise Won-Door FireGuard is also listed as a moveable fire wall (ASTM E-119) in straight, single parting configurations. Door Model Fire Rating Won-Door FireGuard MFWI 1 Hour Won-Door FireGuard MFWII 2 Hours SPECIAL REQUIREMENTS (OPTIONAL): 1. 2. 3. a. b. Exit Hardware may be specified at multiple locations along the door assembly to allow exiting from a space where a single exit device would not be sufficient. (see details on page 35) Vision Panels may be specified to meet code requirements for smoke barriers. (see details on page 33) Access Control Options. Where required, the Won-Door FireGuard assembly can be equipped to provide two levels of access control. (Note: Access Control is disabled when the door is in fire mode.): Level 1 Access Control – Disabled Exit Hardware When the door is in the normal supervisory mode, the door’s exit hardware is programmed to be inactive (it is active in emergency mode only). In addition, the closing system will seek the closed position. If an attempt is made to force the door off its closed limit, it immediately re-closes and sounds an alarm. The alarm can sound locally or remotely. When the door re-closes, the clutch engages for approximately 5 minutes to resist further attempts to force it open. A key switch or other access device is required to open/close the door, therefore specifiers must determine the type and location of the device(s) and specify the required boxes, conduit and wiring in the electrical section of the specification. (See pages 28, 29) For increased security, the standard sliding jamb and “quick release” jamb stops can be replaced with a heavygauge steel sliding jamb and rigid Z-shaped fixed jamb stops. An additional 25 mm of pocket depth is required. Level 2 Access Control – Electromagnetic Locking Device An electromagnetic locking clutch is added to the closing system and provides 182 kg to 227 kg of resistance to opening. A key switch or other access device is required to open/close the door, therefore specifiers must determine the type and location of the device(s) and specify the required boxes, conduit and wiring in the electrical section of the specification. (See pages 28, 29) USING OTHER TYPES OF ACCESS DEVICES (OPTIONAL) In the access control applications, other types of operating devices can be added including numeric keypads, push button and infrared operating devices, providing they are capable of receiving a low voltage signal via stranded 18gauge wire in conduit to the Won-Door automatic closing system control box. Additional operating device contacts can be added as required. These access devices should be defined, provided, and installed under the respective specification section. ADVANCED SYNCHRONIZED LOGISTICS (ASL) (OPTIONAL) The REMOTE CONTROL AND STATUS PC STATION will monitor and control up to 120 FireGuard assemblies and consists of a dedicated personal computer and customized software designed to indicate door status information and to provide remote operation of the doors. (See page 30) Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 13.26 – Horizontal Sliding, Accordion-Type Fire Doors SPECIFICATIONS: PART 1 – GENERAL 1.01 SUMMARY OF WORK A. Division 0 and Division 1, as indexed, apply to this section. B. Furnish and install all horizontal sliding, accordion-type fire doors shown on the drawings and specified herein. 1.02 RELATED SECTIONS A. All headers, support structures, surrounding insulation, jambs, storage pockets, pocket doors, access doors, blocking and trim shall be furnished and installed by other sections. B. All electrical wire, wiring, conduit and electrical boxes shall be furnished and installed by electrical section. C. [All track, soffit, chain guide and wall mounted striker posts shall be painted by Section 09900. Color shall be selected by the architect.] D. [(Note: The following paragraph should be included when 2.04 Option P, ASL-Advanced Synchronized Logistics, is specified) Regarding 2.04 Option P – The Microsoft Windows based PC shall be supplied by the owner. Wiring from the computer to the doors shall be furnished and installed by the electrical section and shall consist of one (1) USOC RJ14-6POS 4 wire jack per line, up to eight (8) lines, installed near the computer. From the computer, each line shall daisy chain up to 32 doors together with one (1) USOC RJ14-6POS 4 wire jack installed on the back wall of the storage pocket for each door. Wire used in the daisy chain shall be a minimum of CAT 3 twisted 2 pair cable. Each line shall be 1219 meters or less in length.] E. [(Note: The following paragraph should be included when 2.04 Option J, individual LCD door status display panel, is specified) Regarding 2.04 Option J– One (1) USOC RJ14-6POS 4 wire jack shall be supplied at the back of the storage pocket and shall be tied to the 4 square junction box adjacent to the door with CAT 3 twisted 2 pair cable. The junction box, RJ14 jack and wire shall be furnished and installed by the electrical section. Termination to the LCD panel shall be by punch down block and shall be by the electrical section as per the manufacturer’s instructions. If the LCD panel is supplied with 2.04 Option J, then the CAT 3 twisted 2 pair cable can be terminated in parallel with the ASL wiring in the same USOC RJ14-6POS 4 wire jack.] 1.03 QUALITY ASSURANCE A. Installation shall be performed by factory trained and certified installers with a minimum of three years experience installing accordion-type fire doors. B. Fire doors shall be tested in accordance with China Test standard GB14102-2005, listed by Underwriters Laboratories, and FM global for ratings as indicated, when tested in accordance with the requirements of UL 10B and ASTM E-2074. Fire doors shall comply with the requirements of the International Building Code Congress and NFPA 5000. C. Automatic closing system shall be tested in accordance with China Test standard GB 14102-2005 and listed by Underwriters Laboratories and FM Global in accordance with the requirements of UL 864 and be intended for use with assembly in compliance with NFPA 80, Chapter 9, Section 9.4.2.1. D. Fire doors used for smoke and draft control shall bear the “S” mark on the fire door label and shall be tested in compliance with China Test standard GB14102. E. Fire doors used at the point of access to an elevator shall bear the “S” mark on the fire door label shall be tested in compliance with China Test standard GB14102. Specifier’s Note Brackets [ ] indicate specifier’s option Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 – Horizontal Sliding, Accordion-Type Fire Doors 1.04 SUBMITTALS A. Refer to Section 01300 - Shop Drawings and Submittals. B. Indicate required stacking depth, storage pocket width and height of header above finished floor. Show installation details, layout, and electrical requirements. 1.05 DELIVERY, STORAGE, AND HANDLING A. Deliver to the job site in manufacturer's original, unopened package. 1.06 COORDINATION BY GENERAL CONTRACTOR A. Coordinate the efforts of the various trades affected by the work of this section. Assure accurate installation of header, jamb, and trim. Provide field dimensions for fabrication. Supervise unloading and handling of materials. B. Permanent power shall be in-place and ready for final connection when fire doors are erected. Assure access to and proper clearance for motor operators. C. After testing the fire alarm system, automatic-closing fire doors shall be re-set to the original positions. D. Store boxes flat (not more than three high) in a dry area and protect from elements that may damage materials. Replace damaged materials at no cost to the owner. 1.07 WARRANTY A. Materials and installation shall be warranted against defects in workmanship for a period of one (1) year from the date of substantial completion. B. [A Manufacturers Service Agreement shall cover years 2 thru 5 and include regularly scheduled testing and inspection of all door functions. The Service Agreement will include [select one: annual, semi-annual, quarterly or monthly] visits to inspect, test and perform all required maintenance. All service and maintenance functions are performed by factory-trained service technicians.] C. [A comprehensive owner training seminar will be conducted by a factory trained service technician. The owner training shall include horizontal sliding, accordion-type fire door operation, care, maintenance, testing and trouble-shooting.] SPECIFICATIONS: PART 2 – PRODUCTS 2.01 MANUFACTURER AND MODEL A. Horizontal sliding accordion-type fire doors shall be Won-Door FireGuard model WDFG[select one: 20, 60, 90, or 180] (number designates minutes of fire rating)(China classification code GFYJ-420480FY3-Cx-S-203) as manufactured by Won-Door Corporation, Salt Lake City, Utah. (Note: Add suffix “S” for smoke and draft OR suffix “E” if door is used at the point of access to an elevator.) B. Products of other manufacturers demonstrating complete compliance with each of the fire rating and performance criteria of the product specified will be considered for approval. Minimum proof of compliance shall include UL 864 9th edition listing, UL test report and independent testing agency report documenting compliance with IBC Section 1008.1.3.3 and NFPA 80, Chapter 9. Written requests for substitutions will be considered by the architect up to ten days prior to the bid date. C. [No substitutions allowed.] 2.02 FIRE RATING A. Fire Doors shall be tested in accordance with China Test standard GB 141102-2005 and listed by Underwriters Laboratory as special purpose fire doors having a fire resistive rating up to three hours in accordance with the requirements of UL 10B and ASTM E-2074. Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 – Horizontal Sliding, Accordion-Type Fire Doors 2.03 REMOTE MONITORING AND CONTROL (Note: Remote Monitoring and Control may be specified under 2.04 Option P) A. Fire doors shall be capable of being remotely monitored and controlled by a personal computer (PC). Information displayed on the computer shall indicate the voltage of the battery, AC line voltage and error conditions. Status information shall indicate whether the door(s) is closed, open, closing, opening, stopped, blocked or locked. Access using the Fire Exit Hardware shall be indicated as well as when the door(s) has received a fire signal. 2.04 MATERIALS A. Construction: shall consist of two parallel, accordion-type walls of panels independently suspended with no floor tracks, pantographs, or interconnections except at the lead-post. B. Panels shall be formed of 24-gauge (.7 mm) enamel coated steel V-grooved for strength and resilience. Panels shall be connected by full height 24-gauge (.7 mm) enamel coated steel hinges. Panels shall be modular in design and capable of in-place repair-ability. C. Suspension System: shall consist of two 14-gauge cold rolled steel (or 3 mm aluminum) tracks on 203 mm centers attached to the overhead structural support. Each lead post shall be suspended by an 8wheel ball bearing trolley. Each panel shall be suspended by a steel hanger pin and a ball bearing roller. D. Lead-posts: shall be of 24-gauge (.7 mm) cold rolled steel and shall be connected by specially formed steel panels. An internally mounted stabilizer bar shall keep lead-posts plumb and in proper alignment during operation and insure a tight fitting closure. E. Perimeter Seals: shall consist of continuous extruded vinyl sweeps attached to the top and bottom of the fire door to form a smoke and draft seal. F. Hanging weight shall be 27 kg/m2. G. Automatic Closing System shall consist of the following: 1. Microprocessor based Electronic Control box with these features: a. Ability to monitor dual power sources continually for peak performance including: i. Detect a missing battery, bad battery, or low battery condition. ii. Detect if the charging circuit is bad. iii. Detect fuse failures. iv. Detect high or low AC conditions. b. Ability to monitor the health of the drive train including: i. Direction errors, obstruction errors, hindrance errors, and position errors. ii. Active daily path checks, by actually closing and opening to assure a clear path and proper operation. iii. Ability to monitor a passive input such as an infrared light beam to assure the closing path is clear. c. Ability to monitor inputs including: i. Sticky door block, exit hardware, patron hardware, and key switches. ii. Key switch mis-wires where key open and key close are both on simultaneously. d. Ability to self-monitor the health of: i. Internal volatile and non-volatile memory. ii. Proper operation of firmware. Specifier’s Note Brackets [ ] indicate specifier’s option Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 – Horizontal Sliding, Accordion-Type Fire Doors 2. 3. 4. 5. e. Ability to run a “watch dog” monitoring circuit which will force a software restart in the event the software hangs, including the ability to track the number of resets that occur for diagnostic purposes. f. Ability to record the number of times the door has closed, opened, lost communication with external microprocessors, and the number of times the controller has been reset manually. g. Ability to monitor ambient temperature and lockout the operating devices once the environment at the door becomes untenable. h. Ability to enter a security mode to help control access through the door including: i. The ability to automatically re-close and secure itself after a legitimate patron access has occurred. ii. The ability to unlock and revert to a fire door in a fire alarm condition, including the ability to re-lock automatically after the fire alarm condition has cleared. i. Ability to withstand voltages up to 120 volts AC on the fire alarm input circuit without damage including the ability to indicate that the alarm circuit has not been wired as a dry contact, “no voltage” circuit when errant voltages are applied to the circuit. j. Ability to communicate with other microprocessors on the system via an internal bus system, including but not limited to microprocessors on the motor drive, in the leading edge of the door, and on a wall mounted display panel adjacent to the door. k. Ability to indicate trouble or supervised information both locally and at a remote location. Motor Operator Assembly including: a. A DC gear-motor, drive sprocket, clutch, and position sensors. The motor shall drive the fire door by means of a chain attached to a stabilizer bar trolley each time the door operates including the initial closing cycle. A door control momentary rocker switch shall be mounted on one side of the door near the lead post and shall have the following functions: Pressing the upper portion of the switch shall close the door and/or clear fault conditions. Pressing the lower portion of the switch shall open the door and/or temporarily mute the local horn. For doors using wall mounted key switches, 2.04 Option I, a color coordinated cover plate shall be provided to fill the hole left when the rocker switch is removed or not used. The control box shall be equipped with a service switch that performs the following functions: a. When the switch is off with AC power present, the controller shall emit an audible coded sound indicating the system is out of service. In this mode all normal functions shall cease including motor and communications. b. When the switch is off and AC power is not present, the controller shall enter a sleep mode during which the system shall use the battery to monitor the AC line for power but do nothing else. c. When the switch is moved from the off position to the on position, the controller shall enter a calibrate mode where it emits a coded audible alert indicating that the door needs to be closed to complete the calibration sequence. As soon as the door is closed, the controller shall automatically stop the audible alert, and resume all normal functions and monitoring. Leading Edge Obstruction Detector: Specifier’s Note Brackets [ ] indicate specifier’s option Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 – Horizontal Sliding, Accordion-Type Fire Doors a. Shall be pressure sensitive such that each contact with an obstruction shall cause the door to stop, reverse enough to remove pressure on the leading edge, pause, and then re-close when in an alarm condition. The leading edge obstruction detector shall be fully functional at all times, including during the initial closing cycle. b. Constant pressure to the leading edge in the direction of opening shall, while the door is opening under motor power, continue to open under motor power until the leading edge is released. This is termed motor assisted opening. c. Constant pressure to the leading edge while not under motor power shall prevent motor operation and allow the door to be opened manually. 6. Exit Hardware shall be located on both sides of each fire door. a. In emergency mode, a slight pressure on the hardware will cause the door to open a minimum of 813 mm, pause for 3 seconds, and then automatically close. b. The open distance shall be field programmable, up to the entire opening width, if the local authority requires an opening larger than 813 mm. c. The pause before re-close shall be field programmable, up to 30 seconds, if the local authority requires a longer pause time. d. The exit hardware shall have the ability when not in the emergency (fire) mode or the security (lock) mode to be used to open the door and move it back into the storage pocket. e. The exit hardware shall be field programmable to provide access control. When programmed, the exit hardware shall not respond when pressed until activated by signal from smoke detector or fire alarm. 7. Suffix “E” doors shall include the following extras; track seals, anti-sway brackets every five feet or less across the opening, modified lead post trolleys and foil tape between the panels and the smoke liner. OPTIONS H. [Vision Panel shall consist of frame and clear glass assembly with listings from Underwriters Laboratory up to 1 1/2 hours]. (Note: required only in smoke barriers in Group I occupancies.) I. [A Key switch module shall be provided.] (Note: required for doors equipped with Access Control devices.) J. [An individual LCD door status display panel shall be provided adjacent to the door to indicate in the English language the status of the door, i.e. door position and trouble conditions. It shall have a port that allows easy access to a diagnostic tool for the purposes of field programming the door to customized settings. When used with the ASL system, it shall be compatible and not disrupt the ASL communications] (Note: Electrical requirements for the LCD panel can be found in 1.02 Option E) K. [Air Pressure Resistance. When the differential pressure on the two sides of the fire resistant and smoke resistant shutter is 20 Pa, the amount of smoke leaked through when it is in a standard state (20 deg C) shall not be greater than 0.2 m3 (m2*min).] L. [An infrared light beam shall be provided on non-curved doors to monitor the opening path. In the event that an object is placed in the path of the door for more than 4 minutes, the beam shall cause the door to sound an alarm indicating a path obstruction.] Specifier’s Note Brackets [ ] indicate specifier’s option Specifications FireGuard 20, 60, 90, 180 SECTION 08 35 13.23 – Horizontal Sliding, Accordion-Type Fire Doors M. [Acoustic Insulation: Interior surfaces of both walls shall be completely covered with a continuous blanket of .454 kg density foil-backed fiberglass fastened in place with steel spring-clips]. (Note: When specifying insulated doors, contact the manufacturer for pocket depths, hanging weight and size limitations.) OPTIONS - ACCESS CONTROL/MONITORING (Note: Level 1 and Level 2 Access Control options are independent systems and may not be specified in conjunction with each other) N. [Level 1 Access Control. The Exit Hardware shall not respond when pressed until activated by signal from smoke detector or fire alarm. Upgrades to the fire door for this level of access control shall include a heavy-gauge steel sliding jamb and rigid jamb stops.] (Note: at least one key-switch required.) O. [Level 2 Access Control. An Electromagnetic lock shall be added to the motor operator assembly to provide 181-226 kg of resistance to manual opening until activated by a signal from fire alarm. When the fire alarm is cleared, the door returns to normal access control. Upgrades to the fire door for this level of access control shall include a heavy-gauge steel sliding jamb, rigid jamb stops and 10-gauge steel vertical reinforcement to the lead post.] (Note: at least one key-switch required.) P. [Advanced Synchronized Logistics- an integrated building asset management system (ASL), as manufactured by Won-Door Corporation, shall be furnished and installed to continuously control and monitor the status of up to 256 doors. ASL shall consist of a Multi-port On-site Monitor box, a serial cable, a 12-volt power supply and software on CD-ROM media. Installation, jacks, a computer (PC) and wiring shall be provided by others.] (Note: Electrical requirements for the ASL system can be found in 1.02 Option D) 2.05 COLOR A. Color shall be manufacturer’s standard #55 Platinum. B. [Color shall be selected from manufacturer's optional colors at additional cost.] C. [Color shall be selected by architect and field painted by others.] SPECIFICATIONS: PART 3 – EXECUTION 3.01 PREPARATION BY GENERAL CONTRACTOR A. Openings shall be to the dimensions specified, plumb and level. B. Headers shall be parallel with the finished floor within ±3 mm tolerance over the entire length of the opening. C. Manufacturer shall make available to the general contractor a DVD showing door opening preparation. 3.02 INSPECTION A. Inspect openings prepared for fire doors and surrounding conditions. Immediately notify the architect, in writing, of any unacceptable conditions. 3.03 INSTALLATION A. Install fire doors in accordance with manufacturer's instructions for clearance and fastenings. B. Adjust for smooth, quiet operation. Verify that all operations are functional and meet the requirements of applicable codes and regulations. C. Upon completion of the installation, general contractor shall protect fire doors from damage and shall replace or repair subsequent damage so that doors are acceptable to the architect at no additional cost to the owner. D. Installation shall be performed by factory trained and certified installers with a minimum of three years experience installing accordion-type fire doors. 3.04 DEMONSTRATION A. Manufacturer’s onsite field technician shall demonstrate the operation of the doors to the General Contractor. A DVD outlining the operation, scheduled maintenance, basic troubleshooting and care of the door system shall be provided to the owner by the door manufacturer. Copyright © 2011 by Won-Door Corporation, all rights reserved. END OF SECTION Specifier’s Note Brackets [ ] indicate specifier’s option This page intentionally left blank. STRAIGHT DOOR – HEAD DETAIL STANDARD HEAD w/POCKET MOUNTED MOTOR CAD FILE: FGHD1METRIC STANDARD HEAD w/POCKET MOUNTED MOTOR CAD FILE: FGHD1 1. 2. 3. 4. 5. 6. 7. 8. 12 mm dia. threaded rod with nuts and washers by others. (457 mm O.C. in opening, 305 mm O.C. in stack area.) 1 layer 19 mm x 438 mm continuous plywood and 2 layers 19 mm x 381 mm continuous plywood. Stagger joints, glue and screw together @ 610 mm O.C. with 2 #7 x 41 mm screws. [OR] 12 mm X 457 mm steel plate. Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Two layers 16 mm x 457 mm x continuous type ”X” gypsum board and three layers 12 mm x 92 mm type “X” gypsum board terminating 305 mm into the pocket. All gypsum to be furnished, installed, finished, and field painted by others. Motor operator unit. (Mounted at back of pocket. (See page 14) Structural support or anchorage by others. Structural support is not limited to concrete deck. Minimum dimension required to meet U.L. compliance. The dimension may be increased to further recess the head condition if required. L-shaped trim piece with pre-finished white color to match track by Won-Door. (Provides transition from track to gypsum soffit.) Specifier’s Note Brackets [ ] indicate specifier’s option STRAIGHT DOOR – PLAN VIEW SINGLE PARTING SINGLE PARTING CAD FILE: FGPL1METRIC 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Sliding jamb assembly. Exit Hardware. Blocking by others. Sliding jamb stops mounted 127 mm back from face of pocket. Non-rated pocket cover door by others. (See page 26, 27) Door bumper by others required when spring loaded hinge is not used by others. (See page 27) Maintain 229 mm clearance on each side of the centerline of the door. Fire rated bulkhead above, drop or flush with ceiling. Striker by Won-Door recessed into rated construction and caulked by others. Center striker pocket on door centerline. Specifier’s Note Brackets [ ] indicate specifier’s option *To determine pocket depth, see the Instructions on page 17 and Pocket Depth Calculation Chart on page 18. STRAIGHT DOOR – PLAN VIEW BI-PARTING BI-PARTING CAD FILE: FGPL2METRIC 1. 2. 3. 4. 5. 6. 7. 8. 9. Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Sliding jamb assembly. Exit Hardware. Blocking by others. Sliding jamb stops mounted 127 mm back from face of pocket. Non-rated pocket cover door by others. (See page 26, 27) Door bumper by others. Bumper required when spring loaded hinge is not used. (See page 27) Maintain 229 mm clearance on each side of the centerline of the door. Fire rated bulkhead above, drop or flush with ceiling. Specifier’s Note Brackets [ ] indicate specifier’s option *To determine pocket depth, see the Instructions on page 17 and Pocket Depth Calculation Chart on page 18. STRAIGHT DOOR – ELEVATION SIDE VIEW STANDARD POCKET MOUNTED MOTOR CAD FILE: FGELEV1METRIC 1. 2. 3. 4. 5. 6. 7. 8. 9. Top of door track. (Fabrication height.) Ceiling line. Motor operator assembly. Folding fire door by Won‐Door. Storage pocket. Electronic control box by Won‐Door. [Optional keyswitch by Won‐Door. (See page 31.] Fire exit hardware. (Allows passage through the door when closed.) Two 102 mm x 102 mm junction boxes surface mounted side by side on back wall of pocket 305 mm above finished floor for required electrical connections. Specifier’s Note Brackets [ ] indicate specifier’s option STRAIGHT DOOR – ELEVATION FRONT VIEW STRAIGHT DOOR CAD FILE: FGELEV4METRIC 1. 2. 3. Fabrication height/field dimension height taken from top of track to top of finished floor. Finished floor. (Carpet, tile, etc.) Sub floor. (Concrete, etc.) Door Profile Widths: • Stacked Width: 406 mm • Extended Width: 292 mm STRAIGHT DOOR – HEAD DETAIL STEEL PAN HEADER STEEL PAN HEAD w/POCKET MOUNTED MOTOR CAD FILE: SPHFGHD1METRIC 1. 2. 3. 4. 12 mm threaded rods, Steel Pan Header and track assembly by Won-Door. Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Motor operator unit. (Mounted at back of pocket. (See page 14) Minimum dimension required to meet U.L. compliance. The dimension may be increased to further recess the head condition if required. Specifier’s Note The Steel Pan Header System may be specified for straight doors less than 9144 mm wide and 3048 tall. POCKET DEPTH CHART INSTRUCTIONS Single Parting Straight Doors The term CLEAR OPENING WIDTH on the Pocket Depth Calculation Chart refers to the distance from the front of the storage pocket to face of the striker. To determine the pocket depth requirement of a door: 1. Determine the door’s CLEAR OPENING WIDTH 2. Find the appropriate range for that width (From-To columns) 3. Refer to the “Single” (for single parting) column. 4. Consult the Options Affecting Pocket Depth section below the chart to determine how optional equipment affects stack requirements. Example below: Pocket depth for FireGuard 60 single parting door w/ 2540 mm clear opening (in the range from 2489 mm to 2692 mm). Minimum pocket depth = 965 mm. Clear Opening Width Min. Pocket Depth From: To: Single Bi-Part 2236 2464 940 1067 2465 2692 965 1092 2693 2921 1016 1143 Bi Parting Straight Doors Bi‐part doors require two storage pockets. Instead of using the total CLEAR OPENING WIDTH when referring to the stack chart, use 1/2 of the CLEAR OPENING WIDTH (which is the distance from the front of storage pocket on one side to the center of the door opening), then follow the same instructions listed in “single parting” (above) to determine the pocket depth requirement. For bi‐parting doors, a motor operator can be placed in each pocket to increase the maximum door size for a standard pocket mounted motor. For unequal bi‐parting doors, consult the factory. Example below: Pocket depth for FireGuard 60 bi‐parting door with 4775 mm clear opening width. Look up 2386 mm on stack chart (1/2 of 4775). Min. pocket depth = 1067 mm for each pocket. Clear Opening Width Min. Pocket Depth From: To: Single Bi-Part 2236 2464 940 1067 2465 2692 965 1092 2693 2921 1016 1143 List of Options Affecting Pocket Depth Once you have determined the appropriate depth requirements using the chart on the next page, consult the Options Affecting Pocket Depth section below the chart. Optional equipment such as the access control sliding jambs, vision panels, and multiple exit hardware will also affect pocket depth as will pocket cover doors in excess of 51 mm thick. STRAIGHT DOOR – POCKET DEPTH CALCULATION CHART FireGuard 20, 60, 90, 180 *For bi‐parting doors: Use Clear Opening Width Single Bi1/2 the clear opening width. Minimum Pocket Depth is Parting Parting From: To: 0 1295 736 863 affected by door height. 1296 1529 762 889 The charts on this page 1530 1762 812 939 show Minimum Pocket 1763 1996 863 965 Depths for doors 3048 mm 1997 2230 889 1016 in height or less. 2231 2463 939 1066 Minimum Pocket Depths for 2464 2697 965 1092 taller doors are shown 2698 2931 1016 1143 Height Single Bi-Part 2932 3164 1041 1168 3165 3398 1092 1219 3048 940 991 3399 3632 1117 1244 3962 1118 1168 3633 3865 1168 1295 3866 4099 1193 1320 4877 1295 1346 4100 4333 1244 1371 below. 4334 4566 1295 1422 4567 4800 1320 1447 For doors over 3048 mm in 4801 5034 1371 1498 height, if the Minimum 5035 5267 1397 1524 Pocket Depth shown on the 5268 5501 1447 1574 charts for the required width 5502 5735 1473 1600 is less than that shown 5736 5969 1524 1651 above use the appropriate 5970 6202 1549 1676 value from above instead. If 6203 6436 1600 1727 it is not, use the value 6437 6670 1625 1778 shown on the charts. For 6671 6903 1676 1803 doors over 4572 mm in 6904 7137 1727 1854 height, the minimum pocket 7138 7371 1752 1879 7372 7604 1803 1930 width of 508 mm is 7605 7838 1828 1955 required. 7839 8072 1879 2006 For doors over 6096 mm in 8073 8305 1905 2032 height, please consult the 8306 8539 1955 2082 factory. The above chart is 8540 8773 1981 2108 for straight door openings 8774 9006 2032 2159 less than 183 m2. For 9007 9240 2082 2209 straight doors openings 2 greater than 183 m , please consult the factory. Clear Opening Width Single BiParting Parting From: To: 9241 9474 2108 2235 9475 9707 2184 2311 9708 9941 2235 2362 9942 10175 2260 2387 10176 10408 2311 2438 10409 10642 2336 2463 10643 10876 2387 2514 10877 11109 2438 2540 11110 11343 2463 2590 11344 11577 2514 2641 11578 11811 2540 2667 11812 12044 2590 2717 12045 12278 2616 2743 12279 12512 2667 2794 12513 12745 2692 2819 12746 12979 2743 2870 12980 13213 2768 2895 13214 13446 2819 2946 13447 13680 2870 2997 13681 13914 2895 3022 13915 14147 2946 3073 14148 14381 2971 3098 14382 14615 3022 3149 14616 14848 3048 3175 14849 15082 3098 3225 15083 15316 3124 3251 15317 15549 3175 3302 15550 15783 3200 3352 15784 16017 3251 3378 16018 16250 3302 3429 16251 16484 3327 3454 16485 16718 3378 3505 16719 16951 3403 3530 16952 17185 3454 3581 17186 17419 3479 3606 17420 17653 3530 3657 17654 17886 3556 3683 17887 18120 3606 3733 18121 18354 3657 3784 OPTIONS AFFECTING POCKET DEPTH: Access Control sliding jamb: Add 25 mm to pocket depth. Pocket Cover Door: Above charts allow for 51 mm thick cover door. Add appropriate amount if cover door and finish materials are thicker than 51 mm. (See page 26, 27) Vision Panel: Add 152 mm to pocket depth. Additional exit hardware: Add 25 mm to pocket depth for each exit device. Maximum of 3 sets of exit hardware per door leaf. FireGuard SE for doors used at the point of access to an elevator: Minimum stack depth is 813 mm. CURVED DOOR – HEAD DETAIL CURVED HEAD w/POCKET MOUNTED MOTOR CAD FILE: FGHD3METRIC 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 12 mm dia. threaded rod with nuts and washers by others. (457 mm O.C. in opening, 305 mm O.C. in stack area.) 3 layers 19 mm x 457 mm continuous plywood and 2 layers 16 mm x 140 mm continuous plywood. Stagger joints, glue and screw together @ 610 mm O.C. with 2 #7 x 41 mm screws. 2 layers 16 mm x 178 mm continuous type “X” gypsum board by others. 2 layers 16 mm x 171 mm continuous type “X” gypsum board by others. Three layers 12 mm x 92 mm type “X” gypsum board terminating 305 mm into the pocket. All gypsum to be furnished, installed finished, and field painted by others. Motor operator unit. (Mounted at back of pocket. See page 14.) Structural support or anchorage by others. (Structural support is not limited to concrete deck.) Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Minimum dimension required to meet U.L. compliance. The dimension may be increased to further recess the head condition if required. L‐shaped trim piece with pre‐finished white color to match track by Won‐Door. (Provides transition from track to gypsum soffit.) Specifier’s Note Brackets [ ] indicate specifier’s option CURVED DOOR – PLAN VIEW SINGLE PARTING CURVED DOOR CAD FILE: FGPL1CURVEDMETRIC 1. Provide rated construction on each side corresponding to rating required for opening by others (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) 2. Sliding jamb assembly. 3. Exit Hardware. 4. Blocking by others. 5. Sliding jamb stops mounted 127 mm back from face of pocket. 6. Non-rated pocket cover door by others. (See page 26, 27) 7. Door bumper by others. Bumper required when spring loaded hinge is not used. (See page 27) 8. Maintain 229 mm clearance on each side of the centerline of the door. 9. Fire rated bulkhead above, drop or flush with ceiling. 10. Striker by Won-Door recessed into rated construction and caulked by others. Specifier’s Note Brackets [ ] indicate specifier’s option *To determine pocket depth, see Instructions on page 24 and Pocket Depth Calculation Chart on page 25. Minimum radius is 1524 mm. Standard radii are 1524 mm and 3048 mm. Custom curves greater than 1524 mm and multiple curves are available. CURVED DOOR – PLAN VIEW BI-PARTING CURVED DOOR CAD FILE: FGPL2CURVEDMETRIC 1. 2. 3. 4. 5. 6. 7. 8. 9. Provide rated construction on each side corresponding to rating required for opening by others. (Note: 1 hour condition shown. To view additional rated conditions, visit our website @ www.wondoor.com) Sliding jamb assembly. Exit Hardware. Blocking by others. Sliding jamb stops mounted 127 mm back from face of pocket. Non-rated pocket cover door by others. (See page 26, 27) Door bumper by others. Bumper required when spring loaded hinge is not used. (See page 27) Maintain 229 mm clearance on each side of the centerline of the door. Fire rated bulkhead above, drop or flush with ceiling. Specifier’s Note Brackets [ ] indicate specifier’s option *To determine pocket depth, see Instructions on page 24 and Pocket Depth Calculation Chart on page 25. Minimum radius is 1524 mm. Standard radii are 1524 mm and 3048 mm. Custom curves greater than 1524 mm and multiple curves are available. CURVED DOOR GUIDELINES 1. 2. 3. Centerline of header. (Radius of curved track is determined by measuring the centerline of the header.) Centerline of outside track. Centerline of inside track. 1. Specifier’s Note 2. Standard 1524 mm and 3048 mm radius with custom curves greater than 1524 mm and multiple curves available. Templates of header radii are supplied to the field upon request. CURVED DOOR – ELEVATION FRONT VIEW CURVED DOOR CAD FILE: FGELEV5 1. 2. 3. Fabrication height/field dimension height taken from top of track to top of finished floor. Finished floor. (Carpet, tile, etc.) Sub floor. (Concrete, etc.) Door Profile Widths: Stacked Width: 406 mm Extended Width: 292 mm POCKET DEPTH CHART INSTRUCTIONS Single Parting Curved Doors The term CLEAR OPENING WIDTH on the Pocket Depth Calculation Chart refers to the distance from the front of the storage pocket to face of the striker. To determine the pocket depth requirement of a door: 1. Determine the door’s CLEAR OPENING WIDTH 2. Find the appropriate range for that width (From-To columns) 3. Refer to the “Single” (for single parting) column. 4. Consult the Options Affecting Pocket Depth section below the chart to determine how optional equipment affects stack requirements. Example below: Pocket depth for FireGuard 60 single parting door w/ 2540 mm clear opening (in the range from 2489 mm to 2692 mm). Minimum pocket depth = 991 mm. Clear Opening Width Min. Pocket Depth From: To: Single Bi-Part 2185 2413 940 1067 2414 2642 991 1118 2643 2870 1016 1143 Bi Parting Curved Doors Bi‐part doors require two storage pockets. Instead of using the total CLEAR OPENING WIDTH when referring to the stack chart, use 1/2 of the CLEAR OPENING WIDTH (which is the distance from the front of storage pocket on one side to the center of the door opening), then follow the same instructions listed in “single parting” (above) to determine the pocket depth requirement. For bi‐parting doors, a motor operator can be placed in each pocket to increase the maximum door size for a standard pocket mounted motor. For unequal bi‐parting doors, consult the factory. Example below: Pocket depth for FireGuard 60 bi‐parting door with 4775 mm clear opening width. Look up 2388 mm on stack chart (1/2 of 4775 mm). Min. pocket depth = 1067 mm for each pocket. Clear Opening Width Min. Pocket Depth From: To: Single Bi-Part 2185 2413 940 1067 2414 2642 991 1118 2643 2870 1016 1143 List of Options Affecting Pocket Depth Once you have determined the appropriate depth requirements using the chart on the next page, consult the Options Affecting Pocket Depth section below the chart. Optional equipment such as the access control sliding jambs, vision panels, and multiple exit hardware will also affect pocket depth as will pocket cover doors in excess of 51 mm thick. CURVED DOOR – POCKET DEPTH CALCULATION CHART FireGuard 20, 60, 90, 180 Clear Opening Width Single BiParting Parting From: To: 0 1295 736 863 1296 1524 762 889 1525 1752 812 939 1753 1981 863 965 1982 2209 889 1016 2210 2438 939 1066 2439 2667 965 1092 2668 2895 1016 1143 2896 3124 1041 1168 3125 3352 1092 1219 3353 3581 1117 1244 3582 3810 1168 1295 3811 4038 1193 1320 4039 4267 1244 1371 4268 4495 1295 1422 4496 4724 1320 1447 4725 4953 1371 1498 4954 5181 1397 1524 5182 5410 1447 1574 5411 5638 1473 1600 5639 5867 1524 1651 5868 6096 1549 1676 6097 6324 1600 1727 6325 6553 1625 1778 6554 6781 1676 1803 6782 7010 1727 1854 7011 7239 1752 1879 7240 7467 1803 1930 7468 7696 1828 1955 7697 7924 1879 2006 7925 8153 1905 2032 8154 8382 1955 2082 8383 8610 1981 2108 8611 8839 2032 2159 8840 9067 2082 2209 9068 9296 2108 2235 9297 9525 2159 2286 152.4 m2, please consult the factory. *For bi‐parting doors: Use 1/2 the clear opening width. Minimum Pocket Depth is affected by door height. The charts on this page show Minimum Pocket Depths for doors 3048 mm in height or less. For single parting doors 3049 -3961 mm in height, the minimum pocket depth is 940 mm. For bi-parting doors 3962-6096 mm in height the minimum pocket depth is 1168 mm. For doors over 3962 mm in height, if the Minimum Pocket Depth shown on the charts for the required width is less than that shown above use the appropriate value from above instead. If it is not, use the value shown on the charts. For doors over 4572 mm in height, the minimum pocket width of 508 mm is required. For doors over 4572 mm in height, please consult the factory. The above chart is for curved door openings less than 152.4 m2. For curved doors openings greater than Clear Opening Width Single BiParting Parting From: To: 9526 9753 2184 2311 9754 9982 2235 2362 9983 10210 2260 2387 10211 10439 2311 2438 10440 10668 2336 2463 10669 10896 2387 2514 10897 11125 2438 2540 11126 11353 2463 2590 11354 11582 2514 2641 11583 11811 2540 2667 11812 12039 2590 2717 12040 12268 2616 2743 12269 12496 2667 2794 12497 12725 2692 2819 12726 12954 2743 2870 12955 13182 2768 2895 13183 13411 2819 2946 13412 13639 2870 2997 13640 13868 2895 3022 13869 14097 2946 3073 14098 14325 2971 3098 14326 14554 3022 3149 14555 14782 3048 3175 14783 15011 3098 3225 15012 15240 3124 3251 15241 15468 3175 3302 15469 15697 3200 3352 15698 15925 3251 3378 15926 16154 3302 3429 16155 16383 3327 3454 16384 16611 3378 3505 16612 16840 3403 3530 16841 17068 3454 3581 17069 17297 3479 3606 17298 17526 3530 3657 17527 17754 3556 3683 17755 17983 3606 3733 OPTIONS AFFECTING POCKET DEPTH: Access Control sliding jamb: Add 25 mm to pocket depth. Pocket Cover Door: Above charts allow for 51 mm thick cover door. Add appropriate amount if cover door and finish materials are thicker than 51 mm. (See page 26, 27) Vision Panel: Add 152 mm to pocket depth. Additional exit hardware: Add 25 mm to pocket depth for each exit device. Maximum of 3 sets of exit hardware per door leaf. FireGuard SE for doors used at the point of access to an elevator: Minimum stack is 813 mm for single parting doors and 940 mm for bi-parting doors. POCKET COVER DOOR GUIDELINES Pocket cover doors are not required, but may be used to aesthetically conceal Won‐Door Fireguard doors. When properly done, they add to the continuity of the project and provide anonymity to the installation. Won‐Door Corporation does not manufacture or install pocket cover doors. Therefore, they should be specified in a separate specification section. Unless specifically required by the Authority Having Jurisdiction, pocket doors need not be fire‐rated, but solid core doors are preferable for reasons of durability. The door thickness and covering material is at the discretion of the designer. Many covering materials have been successfully used including: plastic laminates, wood veneers, vinyl, paint, bronze, stainless steel, and marble. If the aggregate thickness of the pocket cover door exceeds 51 mm, however, the additional thickness must be added to the calculation of the pocket depth (see Pocket Depth Calculation Chart on page 17,24.) Some basic criteria for the successful design of pocket cover doors are listed below: 1. Doors must be side hinge swinging and must swing at least 90°. When in the open position, pocket doors may not encroach on the 457 mm minimum opening width required for the pocket. Designing “notches” on either side of the pocket opening to accommodate the cover door thickness will prevent this (see Pocket Cover Door Detail on page 27.) 2. Cover doors must be operable with less than 22.68 kg of lateral force. As the Won‐Door FireGuard door is activated, the leading edge will make contact with the cover door and push it open. 22.68 kg is the normal operating force required for egress‐type swinging doors and only if the cover door is unusually heavy would special considerations need to be taken. 3. When activated, pocket doors should remain in the open position so as not to obstruct the path of the Won‐Door FireGuard door when it is closing. 4. Won‐Door recommends specifying either (a) a spring‐action such as the Hager #1257 (with reversed spring action)to hold the cover door open when activated or (b) a continuous hinge such as a Stanley #314. a. The reversed spring action in the Hager #1257 butt hinge makes the cover door selfopening rather than self‐closing. Cover doors without spring action hinges may swing back into the operating path of the Won‐Door FireGuard and cause damage or obstruct emergency operation. b. For aesthetic considerations, a continuous hinge is preferable because it does not protrude beyond the face of the pocket cover door and therefore presents a “hinge less” appearance. When a continuous hinge is used, however, a “bumper” is required. The bumper prevents the pocket door from swinging back in to the operating path of the Won‐Door FireGuard. Won‐door does not provide bumpers, but its design is shown on page 27. 5. A magnetic catch not to exceed 13.608 kg can serve to keep the pocket cover doors in the closed position when the Won‐Door Fireguard door is not in use. Positive latches such as hooks or throw bolts are not permitted because they prevent the Won‐door FireGuard door from pushing the cover door open during operation. 6. A door frame is not required although one may be used. For aesthetic considerations, however, a “frame less” design may be preferable because it leaves only two slight reveals at the door edges and provides a less noticeable pocket door installation. POCKET COVER DOOR DETAIL 1. 2. 3. 4. 5. 6. Provide fire rated construction corresponding to rating required for opening by others. Blocking for sliding jamb stops centered at 127 mm from face of pocket by others. Spring action hinge or continuous hinge by others. Non-rated pocket cover door by others. Magnetic catch (not to exceed 13.608 kg) by others. Bumper (mounted on inside of pocket cover door 76 mm above finished floor) by others. Specifier’s Note Bumpers must be specified when non-spring action hinges are used. POCKET MOUNTED MOTOR OPERATOR ELECTRICAL DIAGRAM Specifier’s Note Note: Cable lengths referred to in this detail are actual cable lengths, not straight line distances. If cable length exceeds 7.62 wire meters, consult the factory. Key switch is required with access control. LARGE DOOR MOTOR OPERATOR ASSEMBLY WIRING DIAGRAM Specifier’s Note Note: Cable lengths referred to in this detail are actual cable lengths, not straight line distances. If cable length exceeds 7.62 wire meters, consult the factory. ASL – ADVANCED SYNCHRONIZED LOGISTICS Specifier’s Note The PC-based remote display provides central control and monitoring capabilities for up to 120 fire doors. The display screen monitors current status of each door (closed, closing, open, opening, stopped, blocked, access using fire exit hardware, or locked), battery voltage, and AC line voltage. The remotely located PC allows all monitored Won-Door FireGuard doors to be opened or closed from a central control station. Doors equipped with optional magnetic locks may also be remotely locked or unlocked. Changes in door status are displayed on the monitor when doors are in fire mode or a malfunction is detected. The Remote control and Status Display Station is a dedicated PC for use with Won-Door Fireguard assemblies only. OPTIONAL KEY SWITCH 1. 2. 3. Key switch module. Plaster ring by others. 102 mm x 102 mm x 64 mm electrical box by others. Specifier’s Note Key switches are optional except with access control options. For safety reasons, a key switch must be installed within line-of-sight of the operation of the Won-Door FireGuard door. CCOM ROCKER SWITCH Specifier’s Note CCOM rocker switch is included when a key switch is not specified. The switch is used to open and close the door and to reset and silence door faults. OPTIONAL VISION PANEL 1. 2. 3. Ceiling line. 1 1/2-hour U.L. listed Vision Panel. Required only for smoke barrier applications in Group I occupancies. Maximum size is 146 mm x 67 mm. Exit hardware. Specifier’s Note Add 152 mm to pocket depth for vision panel (except when the vision panel is required to be closer than 1219 mm to the leading edge of the door or 2438 mm on a curved door. In these cases, contact the factory for details.) OPTIONAL SINGLE DOOR DISPLAY 1. 2. 3. Single door display module. Plaster ring by others. 102 mm x 102 mm x 64 mm electrical box by others. Specifier’s Note The Single Door Display communicates door status & fault information to building tenants. Mounted in a standard 102 mm x 102 mm recessed “J” box. OPTIONAL MULTIPLE EXIT HARDWARE DETAIL 1. 2. 3. 4. Top of track. Ceiling line. Finished floor. Exit hardware. (In sets, one on each side of the door, or one side only.) 1. Specifier’s Note 2. Up to three (3) sets of exit hardware per leaf may be specified at any horizontal locations on the door (example above shows two sets in front of a bank of elevators). Upon activation of the exit hardware, the FireGuard door will open to a field-programmable distance. Add 25 mm to stack or pocket depth for each set of exit hardware.