Goetting

Transcription

Goetting
3
4
5
6
8
9
B
three inches = one foot
ABBREVIATIONS
AFF
ABOVE FINISHED FLOOR
EF
ENTRANCE FACILITY
FO
FIBER OPTIC
TELECOMMUNICATIONS SYMBOLS
GROUND
JB
JUNCTION BOX
NTS
NOT TO SCALE
ALL WORK PERFORMED BY THE TELECOMMUNICATIONS CONTRACTOR SHALL BE PERFORMED
IN ACCORDANCE WITH THE EIA/TIA STANDARDS AND BICSI METHODS, AS WELL AS THE
REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION OVER THIS WORK.
1.
1 VOICE AND 3 DATA OUTLET, CATEGORY 6
#
DATA OUTLET, # = QUANTITY OF OUTLETS, CATEGORY 6.
2.
THESE DRAWINGS INDICATE THE GENERAL EXTENT OF THE WORK AND ARE NOT INTENDED TO
INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND
COMPLETION OF THE CONTRACT.
3.
REFER TO ARCHITECTURAL DRAWINGS FOR OUTLET LOCATIONS AND HEIGHTS OF ALL
CONDUIT, SLEEVES, PULL-BOXES, POKE-THROUGHS, STUB UPS AND OUTLET BOXES
REQUIRED FOR TELECOMMUNICATIONS. INSTALLATION SHALL BE PROVIDED BY THE
ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED.
1 VOICE AND 3 DATA FLOORBOX OUTLET, CATEGORY 6
FODP FIBER OPTIC DISTR. PANEL
GRD
GENERAL NOTES
W
[
WALL MOUNTED TELEPHONE OUTLET. (1) CATEGORY 6 CABLE
CONDUIT RUN FROM CABLE TRAY TO OUTLET
CABLE TRAY (BASKET) - SIZE INDICATED ON DRAWING
4.
ALL WORK DETAILED IN THIS DRAWING SET SHALL BE PERFORMED BY THE
TELECOMMUNICATIONS CONTRACTOR UNLESS OTHERWISE NOTED.
5.
CONTRACTOR SHALL COORDINATE CONDUIT AND AND CABLE INSTALLATION WITH OTHER
TRADES AND WITH THE CONSTRUCTION MANAGER.
three quarters inch = one foot
C
P/P
PATCH PANEL
PNL
PANEL
TEL
TELEPHONE
UON
UNLESS OTHERWISE NOTED
CABLE RACK (LADDER) - SIZE INDICATED ON DRAWING
6.
7.
ALL CONDUITS SHALL BE DEBURRED, CLEANED, CAPPED, TAGGED, AND PROVIDED WITH
PULL-STRINGS AND BUSHINGS. WHERE CONDUITS OR WIREWAYS PASS THROUGH FIRE RATED
ASSEMBLIES, THE PENETRATIONS SHALL BE FIRE-STOPPED.
CONTRACTOR TO FOLLOW 90-DEGREE ANGLES AND TAKE THE SHORTEST PATHS SERVING
CABLE TRAYS, CONDUITS OR OTHER PATHWAYS.
8.
THEIR SHALL BE A MINIMUM OF ONE PULL-BOX FOR EVERY 100 FEET OF STRAIGHT CONDUIT
AND A PULL-BOX AFTER TWO 90-DEGREE BENDS. PULL-BOXES SHALL NOT BE USED IN THE
PLACE OF BENDS. ALL PULL-BOXES SHALL BE STRAIGHT-THROUGH.
ALL CABLING INSTALLED OVERHEAD, UNLESS NOTED OTHERWISE, WILL BE ROUTED IN THE
CABLE TRAY OR OPEN SUPPORTED PATHWAYS AS DETAILED ON THE PATHWAY PLANS. ALL
CABLES SHALL BE NEATLY BUNDLED WITH VELCO TIE-WRAPS. CABLE SHALL NOT BE
SUPPORTED BY DUCTWORK, SPRINKLER PIPES, ELECTRICAL CONDUIT, CEILING GRID
SUPPORTS OR GAS PIPES.
D
one half inch = one foot
10.
three eigths inch = one foot
E
C
CONTRACTOR SHALL COORDINATE THE INSTALLATION OF STATION CABLING AND FURNITUR
SYSTEM OUTLETS WITH THE FURNITURE SYSTEM VENDOR, TELECOMMUNICATIONS
CONSULTANT, AND CONSTRUCTION MANAGER.
9.
D
11.
TELECOMMUNICATIONS AND ELECTRICAL CONTRACTORS SHALL REVIEW ALL CONDUIT,
LADDER RACK AND CABLE TRAY SUPPORT CONDITIONS WITH THE GENERAL CONTRACTOR
AND PROJECT ARCHITECT.
12.
CAREFUL COORDINATION WILL BE REQUIRED BETWEEN THE TELECOMMUNICATIONS
CONTRACTOR AND OTHER TRADES. PROVIDE ALL REQUIRED COORDINATED ASSISTANCE AND
INFORMATION IN A TIMELY MANNER.
13.
ALL WALL MOUNTED OUTLETS TO HAVE A 4-11/16" SQUARE, 2-1/2" MINIMUM DEPTH OUTLET
BOX WITH A SINGLE DEVICE PLASTER RING UNLESS OTHERWISE NOTED.
14.
SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND REFLECTED CEILING PLANS
FOR HARD AND ACCESSIBLE CEILING LOCATIONS.
15.
CONTRACTOR SHALL REFER TO THE TELECOMMUNICATIONS SPECIFICATIONS AS WELL AS
TELECOMMUNICATIONS DRAWINGS FOR SPECIFIC PART NUMBERS.
E
REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR GROUNDING DETAILS.
one quarter inch = one foot
16.
MEP ENGINEER
ARCHITECT
Goetting
W
E S T
E
A S T
D
E S I G N
G
TELECOMMUNICATIONS
SYMBOLS & ABBREVIATIONS
R O U P
200 East Grayson, Suite 207 San Antonio, TX 78215
12710 Research Blvd. Suite 355.
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
Project Number
Project Title
Drawing Title
Approved Project Director
RESEARCH ADDITION
TO BUILDING 205
Location
WWW.WESTEASTDESIGN.COM
Date
Building Number
205
Drawing Number
CTVHCS - 1901 S. Veterans Memorial Dr.
Temple, TX 76504
210.530.0755
674-279
Checked
DRAWN
EW
RZ
T1.00
These documents can not be copied or reproduced without written consent from WestEast Design Group
FEBUARY 1, 2013
Revisions:
Date
Dwg. 1 of 8
VA FORM 08-6231
1
2
3
4
5
6
7
8
9
Office of
Construction
and Facilities
Management
Department of
Veterans Affairs
© These documents can not be copied or reproduced without written consent from WestEast Design Group,
USER ID: RZ
DATE: 1/31/2013 9:07:36 PM
FILE: C:\Users\preyes\Documents\VA TEMPLE MEP TTG_preyes(Recovery).rvt
F
1
one eigth inch = one foot
F
7
A
one inch = one foot
B
one and one half inch = one foot
A
2
This document has been produced from material that was stored and/or transmitted electronically and may have been inadvertently altered. Rely only on final hardcopy materials bearing the consultant's original signature and seal.
1
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
1
T TG
12710 Research Blvd. Suite 355
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
TELECOMMUNICATIONS BACKBONE (RISER)
1
T TG
12710 Research Blvd. Suite 355
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
TELECOMMUNICATIONS ONE-LINE DIAGRAM
1
3
three inches = one foot
4
5
6
7
8
9
TELECOMMUNICATIONS KEYED NOTES
This document has been produced from material that was stored and/or transmitted electronically and may have been inadvertently altered. Rely only on final hardcopy materials bearing the consultant's original signature and seal.
B
one and one half inch = one foot
A
2
1
2
PROVIDE CABLE TRAY 4" DEEP X 18' WIDE.
PROVIDE 1"C FROM OUTLET BOX TO CABLE TRAY.
BOND CONDUIT TO CABLE TRAY WITH #6 AWG
GROUND.
A
5
1
2
3
4
H
B
STORAGE
STAIR - 3
1V01
STAIR - 3
UP
F
HALLWAY
VESTIBULE
GOWNING AREA
1H1
1V02
1V05
MICE COLONY
(TYPICAL)
1
1V06
one inch = one foot
E
WOMEN LR.
MEN LR.
1V03
1V04
WOMEN RR
MEN RR
1V03a
1V04a
RAT COLONY
C
C
1V08
TELECOMMUNICATIONS GENERAL NOTES
D
three quarters inch = one foot
PROCEDURE ROOM
PROCEDURE ROOM
PROCEDURE ROOM
1V14
1V13
VESTIBULE
1V18
ABSL-2 HOLDING &
PROCEDURE AREA
1V10
W
2
W
2
1V10b
1V10a
HALLWAY
2
2
W
1H2
W
HALLWAY
(TYPICAL)HALLWAY
1
1H3
1H4
W
CLEAN SIDE
1V20
W
2
ABSL-2 HOLDING AREA
NECROPSY
2
CLEAN CAGE STORAGE
1V12
D
1V20a
PROCEDURE ROOM
W
1V16
2
1V19
PROCEDURE ROOM
AUTOCLAVE
1V17
one half inch = one foot
D
PALLET STORAGE
C
1V16a
FEED & BEDDING
1V21
PLASTIC RECYCLING
STORAGE
2
SOILED SIDE
2
TECH OFFICE
1V23
HALLWAY
GOWNING AREA
1V25b
1V25
1H5
1V22
2
E
2
2
ELEV. - 3
VETERINARIAN OFFICE
ELEV - 3
three eigths inch = one foot
2
1V23a
ELEV.M.R.
1V31
1V32
(TYPICAL)
1
W
TANK STOR.
2
B
2
ELECT.
STAIR - 4
W
E
1V26
STAIR - 4
WASTE STORAGE
IT / TELECOMM
1V29
1V28
TEMP. HOLD.
1V27
RADIO. WASTE
BUILDING 205
1V30
A
A
N
N
one quarter inch = one foot
1
0 1'
LEVEL 1 - TELECOM
1/8" = 1'-0"
4'
Project
8'
16'
F
MEP ENGINEER
ARCHITECT
Goetting
W
E S T
E
A S T
D
E S I G N
G
TELECOMMUNICATIONS PLAN
FIRST FLOOR
R O U P
200 East Grayson, Suite 207 San Antonio, TX 78215
12710 Research Blvd. Suite 355.
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
Project Number
Project Title
Drawing Title
Approved Project Director
RESEARCH ADDITION
TO BUILDING 205
Location
WWW.WESTEASTDESIGN.COM
Date
Building Number
205
Drawing Number
CTVHCS - 1901 S. Veterans Memorial Dr.
Temple, TX 76504
210.530.0755
674-279
Checked
DRAWN
EW
RZ
T2.01
These documents can not be copied or reproduced without written consent from WestEast Design Group
FEBUARY 1, 2013
Revisions:
Date
Dwg. 4 of 8
VA FORM 08-6231
1
2
3
4
5
6
7
8
9
Office of
Construction
and Facilities
Management
Department of
Veterans Affairs
© These documents can not be copied or reproduced without written consent from WestEast Design Group,
USER ID: RZ
DATE: 1/31/2013 9:18:14 PM
FILE: C:\Users\preyes\Documents\VA TEMPLE MEP TTG_preyes(Recovery).rvt
KEY PLAN
1
one eigth inch = one foot
F
ue
Tr
B
TELECOMMUNICATIONS KEYED NOTES
1
2
5
1
2
3
PROVIDE CABLE TRAY 4" DEEP X 18' WIDE.
PROVIDE 1"C FROM OUTLET BOX TO CABLE TRAY.
BOND CONDUIT TO CABLE TRAY WITH #6 AWG
GROUND.
4
H
LAB
2R38
STAIR - 3
UP
HALLWAY
2C2.1
(TYPICAL)
F
HALLWAY
2H1
1
2
2
2
W
CORE EQUIP.
2
2R40
LAB
E
HAC
2R39
LAB #10
2R41
2R46
TISSUE
CULTURE
ROOM
2
W
2
2R41a
2
2
2
D
2
D
AIR
PLENUM
2
2
2R42a
2
TISSUE
2
CULTURE
ROOM
MECHANICAL
ROOM
HALLWAY
2H2
2R42
TELECOMMUNICATIONS GENERAL NOTES
2
2R43a
1
W
(TYPICAL)
LAB #11
2R43
2
2
2
C
C
COLD
PROCEDURE
ROOM
W
2
2
2
2
2R44
2
CORE
EQUIPMENT
2R45
ELECTRON
MICROSCOPE
SUITE,
PREPARATION
ROOM /LAB
2
2R47
W
W
2
ELEV. - 3
W
2
SCOPE ROOM
2 SUPPORT
2R47a
B
ELECTRICAL
ROOM
IT /
TELECOMM
2R48
STAIR - 4
(TYPICAL)
A
12710 Research Blvd. Suite 355
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
2R47b
ELECTRON
MICROSCOPE
SUITE,
MICROTOME
ALCOVE
2R47c
B
2
2R49
1
A
1
T TG
ELECTRON
MICROSCOPE
2
SUITE,
SCOPE
ROOM
2
LEVEL 2 - TELECOM
1/8" = 1'-0"
B
three inches = one foot
one and one half inch = one foot
A
2
3
This document has been produced from material that was stored and/or transmitted electronically and may have been inadvertently altered. Rely only on final hardcopy materials bearing the consultant's original signature and seal.
1
4
5
6
7
8
9
A
1
9
MGMT 2RU
36-PORT FODP
16
GENERAL NOTES:
MGMT 2RU
9
VOICE TIE CABLE
1
9
MGMT 2RU
9
MGMT 2RU
MGMT 2RU
9
MGMT 2RU
MGMT 2RU
MGMT 2RU
CONTRACTOR TO COORDINATE OVERHEAD LADDER RACK AND REQUIRED METAL
DROP-OUTS WITH THE EQUIPMENT RACKS AND VERTICAL CABLE MANAGERS.
10
2.
CONTRACTOR TO COORDINATE LADDER RACK WITH THE CONDUITS AND SLEEVES
INSTALLED BY THE ELECTRICAL CONTRACTOR.
10
3.
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL THE TELECOMMUNICATIONS MAIN
GROUND BAR (TMGB) & TELECOMMUNICATIONS GROUND BAR IF REQUIRED.
9
10
12
1.
20
9
10
9
5
8
7
5
1
three quarters inch = one foot
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL RISER SLEEVES, CONDUITS,
ETC. UNLESS OTHERWISE NOTED.
6.
CONTRACTOR IS TO ENSURE THAT ALL CABLING, POWER WIRING, AND/OR OTHER OBJECTS
DOES NOT INTERFERE WITH THE INSTALLATION OF EQUIPMENT IN THE EQUIPMENT RACKS.
7.
CONTRACTOR TO FURNISH AND INSTALL, IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS, ALL MISCELLANEOUS HARDWARE REQUIRED TO INSTALL THE
EQUIPMENT SHOWN ON ALL "T" SERIES DRAWINGS.
8.
ALL CABLES ARE TO BE NEATLY BUNDLED AND FASTENED TO WALLS, EQUIPMENT RACKS,
AND, CABLE RACKS WITH VELCRO TIE WRAPS.
9.
CABLE TROUGHS AND THE FRONT SIDE OF THE VERTICAL CABLE MANAGER ARE FOR THE
ROUTING OF PATCH CORDS AND NOT FOR ROUTING OF HORIZONTAL OR TIE CABLES. THE
HORIZONTAL OR TIE CABLES SHALL BE ROUTED THROUGH THE REAR MOUNTING BRACKET
OF THE VERTICAL CABLE MANAGER AND VELCRO TIE WRAPPED.
10.
CONTRACTOR TO GROUND EACH EQUIPMENT RACK, EACH LADDER RACK AND BOND THE
LADDER RACK TO CABLE TRAY VIA SLEEVE IN THE WALL TO THE TMGB/TGB WITHIN THE
TELECOMMUNICATIONS ROOM WITH A MINIMUM OF #6 AWG GREEN INSULATED STRANDED
GROUND WIRE.
11.
EACH EQUIPMENT RACK IS TO BE BOLTED DIRECTLY TO THE FLOOR SLAB WITH (4)
ANCHORS, BOLTS, NUTS AND WASHERS AND SECURED TO THE ABOVE CABLE RACK.
12.
ALL TELECOMMUNICATIONS, COAXIAL CONNECTORS, AND DISTRIBUTION CABLING WITHIN
THE BUILDING TO BE FURNISH, INSTALLED, AND TESTED BY THE COMMUNICATIONS
CONTRACTOR.
13.
ELECTRICAL CONTRACTOR SHALL PROVIDE TWO CLEAN POWER 20-AMP MULTI-OUTLET
ASSEMBLIES ON WALL NEAR EQUIPMENT RACK IN TELECOMMUNICATIONS ROOMS.
15
2
POWER STRIP
POWER STRIP
POWER STRIP
POWER STRIP
RACK 2 DATA
RACK 1 VOICE
2
12
3
6
6
1
TR-1 (ROOM 1V28) LAYOUT
1
5.
2
17
RACK 1 VOICE
4
C
ELECTRICAL OUTLETS AND JUNCTION BOXES ARE SHOWN FOR REFERENCE ONLY. REFER
TO ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR DETAILS.
7
2
RACK 2 DATA
12
FRONT
one inch = one foot
13
4.
B
2
2
SCALE: NTS
TR-1 (ROOM 1V28) EQUIPMENT RACK ELEVATIONS
SCALE: NTS
KEYED NOTES:
1
D
C
GENERAL CONTRACTOR SHALL FURNISH AND INSTALL 4'x8'x
3/ "
4
FIRE RETARDANT PLYWOOD.
2
FURNISH AND INSTALL 120 VAC POWER STRIPS.
3
ELECTRICAL CONTRACTOR - FURNISH AND INSTALL (2) 4" PVC RISER SLEEVES TO SECOND FLOOR.
4
FURNISH AND INSTALL (2) 4" PVC WALL SLEEVES WITH BUSHINGS TO ACCESS CABLE TRAY IN HALLWAY, FIRE STOP.
5
FURNISH AND INSTALL 18" LADDER RACK, TELCO STYLE.
6
FURNISH AND INSTALL (2) 84" EIA 19" EQUIPMENT RACK (TYPICAL)
3/ "
8
D
one half inch = one foot
3
19
20
FIRE RETARDANT
PLYWOOD
18
1
CORNER
CORNER
COLUMN
7
8
9
FIRE RETARDANT
PLYWOOD
10
FURNISH AND INSTALL (2) 6" VERTICAL CABLE MANAGERS, DOUBLED SIDED & HINGED COVERS.
FURNISH AND INSTALL (1) 8" VERTICAL CABLE MANAGER, DOUBLED SIDED & HINGED COVERS.
FURNISH AND INSTALL HORIZONTAL CABLE MANAGER WITH DOUBLE HINGED COVER (2 RUs).
FURNISH AND INSTALL 48-PORT, CATEGORY 6, PATCH PANELS.
1
11
FURNISH AND INSTALL "D-RINGS" AS REQUIRED.
FURNISH AND INSTALL WALL BRACKET KIT - CPI P/N 11421-718 OR APPROVED EQUAL.
12
three eigths inch = one foot
E
FURNISH AND INSTALL WOOD 2'X4"X24" BACK SUPPRT FOR WALL BRACKET, PAINT GRAY.
13
21
15
FURNISH AND INSTALL 36-PORT FIBER OPTIC DISTRIBUTION PANEL.
16
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL TMGB IN ACCORDANCE WITH J-STD-607-A.
17
FURNISH AND INSTALL 110-300 CONNECTOR BLOCK, CATEGORY 5E, FOR RISER CABLES.
TR-1 (ROOM 1V28) LAYOUT - SOUTH WALL
18
SCALE: NTS
one quarter inch = one foot
3
19
FURNISH AND INSTALL 50-PAIR, CATEGORY 3, UTP, PLENUM CABLE. TERMINATE 50-PAIR ON 110-BLOCK & 48-PAIR ON 48-PORT
PATCH PANEL, PAIR 1 ON EACH PORT IN TR-2, VOICE RACK.
20
FURNISH AND INSTALL 50-PAIR, CATEGORY 3, UTP, PLENUM CABLE. TERMINATE 50-PAIR ON 110-BLOCK & 48-PAIR ON 48-PORT
PATCH PANEL, PAIR 1 ON EACH PORT IN TR-1, VOICE RACK.
21
ELECTRICAL CONTRACTOR - FURNISH AND INSTALL 120 VAC, 20 AMP, QUAD OUTLET.
MEP ENGINEER
ARCHITECT
Goetting
W
E S T
E
A S T
D
E S I G N
G
ENLARGED PLAN - FIRST FLOOR
TELECOM ROOM
R O U P
200 East Grayson, Suite 207 San Antonio, TX 78215
12710 Research Blvd. Suite 355.
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
Project Number
Project Title
Drawing Title
Approved Project Director
RESEARCH ADDITION
TO BUILDING 205
Location
WWW.WESTEASTDESIGN.COM
Date
Building Number
205
Drawing Number
CTVHCS - 1901 S. Veterans Memorial Dr.
Temple, TX 76504
210.530.0755
674-279
Checked
DRAWN
EW
RZ
T3.01
These documents can not be copied or reproduced without written consent from WestEast Design Group
FEBUARY 1, 2013
Revisions:
Date
Dwg. 6 of 8
VA FORM 08-6231
1
2
3
4
5
6
7
8
9
Office of
Construction
and Facilities
Management
Department of
Veterans Affairs
© These documents can not be copied or reproduced without written consent from WestEast Design Group,
USER ID: RZ
DATE: 1/31/2013 9:07:42 PM
FILE: C:\Users\preyes\Documents\VA TEMPLE MEP TTG_preyes(Recovery).rvt
F
1
one eigth inch = one foot
F
E
FURNISH AND INSTALL CABLE RACK SPLICE JUNCTION KIT - CPI P/N 11302-701 OR APPROVED EQUAL.
MGMT 2RU
1
3
TR-2 (ROOM 2R49) LAYOUT
TR-2 (ROOM 2R49) LAYOUT - SOUTH WALL
T TG
12710 Research Blvd. Suite 355
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
2
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
MGMT 2RU
TR-2 (ROOM 2R49) EQUIPMENT RACK ELEVATIONS
B
three inches = one foot
one and one half inch = one foot
A
2
This document has been produced from material that was stored and/or transmitted electronically and may have been inadvertently altered. Rely only on final hardcopy materials bearing the consultant's original signature and seal.
1
3
4
5
6
7
8
9
A
(1) 1" EMT CONDUIT TO SBOVE ACCESSABLE CEILING AND TO
CABLE TRAY. PROVIDED BY ELECTRICAL CONTRACTOR.
PAIR 2
STRUCTURE
4-11/16" SQUARE 2-1/8" DEEP BACK BOX (SIMILAR TO RACO-259)
WITH SINGLE GANG FACEPLATE (MUD RING). PROVIDED BY ELECTRICAL CONTRACTOR.
PAIR 3
PAIR 1
PAIR 4
B
NUT, TYP.
1 2 3 4 5 6 7 8
W-O O W-G BL W-BL G W-BR BR
TRAPEZE SUPPORT, TYP.
2"
JACK POSITIONS
one inch = one foot
S
S
1-PORT STAINLESS STEEL FACEPLATE. PROVIDED
BY THE COMMUNICATIONS CONTRACTOR.
WIRE-TYPE CABLE TRAY
12" OR 18" (WIDTH VARIES)
VOICE CAT. 6 RG-45 MODULAR CONNECTOR. COLOR
AS SPECIFIED IN SPECIFICATION. PROVIDED BY COMMUNICATIONS CONTRACTOR.
NOTE: SUPPORT CABLE TRAY IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
T568A PIN-OUT
W
C
C
T568A RJ45 JACK PINOUT TERMINATION
three quarters inch = one foot
5
3
SCALE: NTS
BASKET TRAY DETAIL (TYPICAL)
1
SCALE:NTS
WALL MOUNTED TELEPHONE DETAIL (TYPICAL)
SCALE: NTS
(1) 1" EMT CONDUIT TO SBOVE ACCESSABLE
CEILING AND TO CABLE TRAY. PROVIDED BY ELECTRICAL CONTRACTOR.
(1) 1" EMT CONDUIT TO ABOVE ACCESSABLE CEILING AND TO
CABLE TRAY. PROVIDED BY ELECTRICAL CONTRACTOR.
4-11/16" SQUARE 2-1/8" DEEP BACK BOX
(SIMILAR TO RACO-259) WITH SINGLE GANG
FACEPLATE (MUD RING). PROVIDED BY ELECTRICAL CONTRACTOR.
4-11/16" SQUARE 2-1/8" DEEP BACK BOX (SIMILAR TO
RACO-259) WITH SINGLE GANG FACEPLATE (MUD RING).
PROVIDED BY ELECTRICAL CONTRACTOR.
D
SEQUENCE PER EACH TELECOMMUNICATIONS ROOM
D
one half inch = one foot
FOR EXAMPLE: 1ST TR = "1" AND 1ST PANEL = "A", THEN PORT NUMBER CABLED, E.G., "1-A01".
A
1
24
MGMT 2RU
B
1
48
V1
D1
D2
D3
three eigths inch = one foot
(2) CAT. 6 RG-45 MODULAR CONNECTOR. COLOR AS
SPECIFIED IN SPECIFICATION. PROVIDED BY COMMUNICATIONS CONTRACTOR.
D1
V1
(3) DATA CAT. 6 RG-45 MODULAR
CONNECTOR. COLOR AS SPECIFIED IN
SPECIFICATION. PROVIDED BY COMMUNICATIONS CONTRACTOR.
E
(2) PORTS WITH BLANK COVERS. COLOR AS
SPECIFIED IN SPECIFICATION. PROVIDED BY COMMUNICATIONS CONTRACTOR.
E
PORT DESIGNATOR
PANEL DESIGNATOR
3
PATCH PANEL LABELING EXAMPLE
SCALE: NTS
4
WALL MOUNTED 4-PORT OUTLET DETAIL (TYPICAL)
2
SCALE: NTS
WALL MOUNTED 2-PORT OUTLET DETAIL
SCALE: NTS
one quarter inch = one foot
6
MEP ENGINEER
ARCHITECT
Goetting
W
E S T
E
A S T
D
E S I G N
G
TELECOMMUNICATIONS
INSTALLATION DETAILS
R O U P
200 East Grayson, Suite 207 San Antonio, TX 78215
12710 Research Blvd. Suite 355.
Austin, Texas 78759
512.416.1654 FAX:512.416.7547
Project Number
Project Title
Drawing Title
Approved Project Director
RESEARCH ADDITION
TO BUILDING 205
Location
WWW.WESTEASTDESIGN.COM
Date
Building Number
205
Drawing Number
CTVHCS - 1901 S. Veterans Memorial Dr.
Temple, TX 76504
210.530.0755
674-279
Checked
DRAWN
EW
RZ
T4.01
These documents can not be copied or reproduced without written consent from WestEast Design Group
FEBUARY 1, 2013
Revisions:
Date
Dwg. 8 of 8
VA FORM 08-6231
1
2
3
4
5
6
7
8
9
Office of
Construction
and Facilities
Management
Department of
Veterans Affairs
© These documents can not be copied or reproduced without written consent from WestEast Design Group,
USER ID: RZ
DATE: 1/31/2013 9:07:43 PM
FILE: C:\Users\preyes\Documents\VA TEMPLE MEP TTG_preyes(Recovery).rvt
F
1
one eigth inch = one foot
F
4-PORT FACEPLATE COLOR WHITE OR IVORY TO MATCH
ELECTRICAL FACEPLATES. PROVIDED BY THE COMMUNICATIONS CONTRACTOR.
4-PORT FACEPLATE COLOR WHITE OR
IVORY TO MATCH ELECTRICAL
FACEPLATES. PROVIDED BY THE COMMUNICATIONS CONTRACTOR.
VOICE CAT. 6 RG-45 MODULAR
CONNECTOR. COLOR AS SPECIFIED
IN SPECIFICATION. PROVIDED BY COMMUNICATIONS CONTRACTOR.