certified home ventilating products directory

Transcription

certified home ventilating products directory
HVI Publication 911©
September 1, 2012
CERTIFIED
HOME VENTILATING
PRODUCTS
DIRECTORY
Certified Ratings in Air Delivery, Sound and Energy for Accurate
Specifications and Comparisons
Uniform Construction Index Classification
Assigned by the American Institute of Architects
11d Residential Equipment
88778
HOME VENTILATING INSTITUTE
3317 E. Bell Rd., Ste. 101122
Phoenix, AZ 85032 USA
Phone: 855.HVI.VENT (855.484.8368)
www.hvi.org
INDEX
PRODUCT CATEGORIES BY SECTION
SECTION 1

Bathroom Exhaust Fans

Downdraft Kitchen Exhausters

Inline Fans

Integrated Supply & Exhaust Ventilators

Kitchen Exhaust Fans

Kitchen Range Hoods – Ducted & Convertible

Other Room/Utility Room Exhaust Fans

Powered Attic Ventilators

Remote Exterior Mounted Ventilators

Whole House Comfort Ventilators

Soffit Vents

Energy Recovery Ventilators

Heat Recovery Ventilators
SECTION 2
SECTION 3
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 1
Abreezo ................................................................................ 1
ACME ................................................................................... 1
Aero Pure........................................................................... 1-2
Air King ........................................................................... 2--9
Aira (Canada) ..................................................................... 10
Air Specialty Canada, Ltd ................................................... 62
Airzone................................................................................ 10
American Aldes ................................................................... 10
Apollo .................................................................................. 62
AUPU ............................................................................. 50-51
Best................................................................................10-12
Broan ............................................................................. 13-28
Broan (Canada) ............................................................ 28-34
Broan-NuTone .................................................................... 35
Carnes Company ................................................................ 49
CFM .............................................................................. .44-45
Clever ................................................................................. 76
Cyclone Range Hoods ........................................................ 56
Dayton ................................................................................ 49
Delta ................................................................................... 45
Economizer ........................................................................... 1
Ekolos ................................................................................. 60
Elica .................................................................................... 45
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 1 (continued)
Elicent ................................................................................. 55
Eurodesign ..................................................................... 69-70
Fanam................................................................................. 54
Fantech ......................................................................... 66-69
GE Appliances ............................................................... 46-47
GE Industrial Systems ................................................... 48-49
GNN .................................................................................... 49
GuardianPlus Air Systems .................................................. 35
Haier .............................................................................. 49-50
Hampton Bay ...................................................................... 51
Harbor Breeze .................................................................... 54
HomeAire ............................................................................ 64
Homewerks Worldwide ....................................................... 51
Hoover ........................................................................... 51-52
Humidex................................................................................ 9
Hunter ................................................................................. 52
Infinitech ........................................................................ 52-53
Jetko ................................................................................... 53
K-Star.................................................................................. 53
Kanaire ............................................................................... 54
Kenmore ............................................................................. 70
Kenmore (Canada) ........................................................ 35-36
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 1 (continued)
King of Fans ........................................................................ 53
Lonon .................................................................................. 53
Mabe ................................................................................... 53
Marley ........................................................................... 55. 62
Milano ................................................................................. 56
Monogram ...................................................................... 47-48
NuTone .......................................................................... 36-41
NuTone (Canada) .......................................................... 41-44
Nuvent ................................................................................ 74
Orbit Fans ...................................................................... 56-57
Ortech ................................................................................. 57
Ostberg Americas .......................................................... 57-58
Panasonic ...................................................................... 58-60
Prime .................................................................................. 60
Progress Lighting ................................................................ 60
Quantum ............................................................................... 2
RadonAway ........................................................................ 65
RenewAire .......................................................................... 62
Reversomatic ................................................................. 62-63
Rheem ................................................................................ 63
Rona ............................................................................... 9, 74
Softaire ............................................................................... 63
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 1 (continued)
Soler & Palau ...................................................................... 64
Spruce ................................................................................ 65
Stelpro ........................................................................... 65-66
Sterling................................................................................ 61
Superfan ............................................................................. 66
Systemair ............................................................................ 69
Totaline ............................................................................... 69
Tuscany .............................................................................. 53
Uberhaus Design ................................................................ 64
Venmar .......................................................................... 70-72
Venmar Connaisseur ..................................................... 72-73
Venmar Jazz .................................................................. 73-74
Vents.............................................................................. 74-75
Whirlpool ........................................................................ 45-46
Win Air ................................................................................ 76
Windridge Fans ................................................................... 75
Zephyr................................................................................. 76
Zonex .................................................................................. 56
SECTION 2
Quality Aluminum .................................................................. 1
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 3
Aeromatic.......................................................................... 1-3
Airflow ................................................................................ 4-6
Airia Brands Inc. (Lifebreath®)......................................... 7-17
Air King .......................................................................... 17-19
Airtech-107 ......................................................................... 20
Alpine Pure .................................................................... 20-22
Amana Brand Indoor Air Quality Products ..................... 22-24
American Aldes .............................................................. 25-28
American Standard ........................................................ 29-30
Broan-NuTone ............................................................... 30-34
Bryant ............................................................................ 35-40
Carrier ............................................................................ 41-46
Fantech ......................................................................... 44-56
Field Controls ................................................................. 56-58
General Aire ........................................................................ 59
Goodman Indoor Air Quality Products ........................... 60-63
Greentek ........................................................................ 66-73
Honeywell ...................................................................... 63-66
Imperial .......................................................................... 74-81
Kenmore ............................................................................. 81
Lennox ........................................................................... 82-86
Lifebreath® ...................................................................... 7-17
Napoleon ............................................................................ 87
INDEX
BRAND NAMES BY SECTION
BRAND
PAGE/S
SECTION 3 (continued)
Nu-Air............................................................................. 88-93
Powrmatic of Canada, Ltd. (Direct Air) ........................ 94-101
RenewAire ................................................................. 102-104
Reversomatic ............................................................. 105-107
Rheem ....................................................................... 107-109
Ruud .......................................................................... 110-111
Sears Indoor Clean Air Services ....................................... 112
Soler & Palau ............................................................. 113-114
Standex Air Distribution Products .............................. 115-117
Titan ........................................................................... 118-119
Totaline ............................................................................. 120
Trane ......................................................................... 121-122
Trent Metals, Ltd. ....................................................... 123-130
vanEE ........................................................................ 131-145
Venmar Ventilation..................................................... 146-166
York .................................................................................. 167
Zehnder ............................................................................ 168
FOR MORE INFORMATION
Detailed information on proper ventilation is available online at
http://www.hvi.org.
Product catalogs with model illustrations, descriptions, specifications and
installation instructions are available from any of the manufacturers whose
products are listed in this directory.
LOOK FOR THESE HVI-CERTIFIED LABELS
Every HVI-Certified product is required to have an HVI-Certified Label affixed.
CALIFORNIA ENERGY COMMISSION Compliance Statement As of September 1, 2012 Section 1 of this directory has been approved by the California Energy Commission (Commission) for determining compliance with its Appliance Efficiency Regulations (Title 20, California Code of Regulations, Sections 1601‐1608) and its building standards (Title 24, California Code of Regulations, Part 6). UNLESS INDICATED OTHERWISE, any appliance* listed in Section 1 of this directory may be sold, offered for sale, or installed in new construction in California. For appliances manufactured by manufacturers participating in this directory, but who have not given authorization for data submittal to the Commission, this directory cannot be used for determining compliance. For information about such appliances, appliances that are beyond the scope of this directory, or appliances produced by manufacturers who do not participate in this directory, please contact the Commission's Building Standards Hotline at (916) 654‐5106, (800) 772‐3300 (in California only), or [email protected]. Manufacturers granting authorization for data submittal to the Commission as of the publication date of this directory include:  American Aldes Ventilation Corporation  Continental Fan Manufacturing  Delta Products  Fan Am, Inc.  Hangzhou Aupu Bathroom & Kitchen Technology Co. Ltd.  Homewerks Worldwide  Milano Electronics LLC  Orbit Industries  Qingdao Xingbang Electronic Appliances Co. Ltd.  Panasonic Home & Environment Co.  Renewaire LLC  Reversomatic Mfg. Ltd.  Spruce Environmental Technologies  Systemair Inc.  Ventamatic Ltd.  Windridge Fans Corporation Ltd.  Zhongshan Airzone Ventilated Technology *qualifying appliances are limited to the following product categories:  Bathroom exhaust fans  Other room/utility room exhaust fans  Inline fans  Kitchen range hoods  Whole house comfort ventilators SECTION I
HVI TESTED/CERTIFIED
Static
Pressures:
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static
pressure)
Fan Operating
Speeds:
BS+ = BOOST SPEED
HS+ = HIGH SPEED
LS+ = LOW SPEED
HOME VENTILATING FANS
•
•
•
•
•
•
•
•
•
•
Bathroom - Exhaust Fans
Downdraft Kitchen Exhausters
Inline Fans (all models)
Integrated Supply & Exhaust Ventilators
Kitchen Fans
Kitchen Range Hoods – Ducted & Convertible
Other Rooms – Exhaust Fans
Powered Attic Ventilators
Remote Exterior Mounted Ventilators
Whole House Comfort Ventilators
HVI Tested/Certified air delivery ratings are in Cubic Feet Per Minute (CFM).
HVI Tested/Certified sound emission ratings are in sones (S).
USE OF HVI LABEL
Companies whose products have been certified by HVI shall affix appropriate Labels to those products
RATINGS
FOR
QUALITY,
QUIETNESS
This directory lists the only
ventilating fans, which offer
a complete and uniform
basis for comparison and
rated performance – those,
which bear the HVI Tested/
Certified Label. Listed
herein are range hoods,
wall and ceiling exhaust fans, whole house fans and
powered attic space ventilators, which conform to HVI's
standards.
All HVI ratings for fans are based on independent tests at
HVI approved laboratories. Each fan is tested under
specific air resistance and other conditions related to
actual application, as distinct from "free air" or other nonstandard conditions.
Indoor fans carry dual ratings, for quietness as well as
ventilating performance. Simple validated numbers tell
the air movement in CFM (cubic feet per minute) and the
sound output in sones. Exterior-mount ventilators, usually
ducted to the kitchen, offer high capacity and quietness.
Whether their tasks are removal of the odors, fumes,
smoke, moisture and heat of indoor air pollution or
automatic removal of summer heat and winter moisture
from attics, fans with the HVI Label can be depended on
to exhaust the amount of air for which they are rated. All
are true ventilators, as distinguished from recirculating
devices.
HVI lists ratings in steps of 10 CFM and 0.5 sones. Fans
of multiple speeds must be rated for sound at maximum
CFM ratings and may be rated also at lower CFM levels.
Sone ratings permit easy and accurate comparisons of
exhaust fans tested under identical laboratory standards
and conditions. A fan rated at 3 sones makes half the
sound of one of 6 sones, just as 100 CFM is half the air
movement of 200 CFM. For adequate ventilation, the
Home Ventilating Institute recommends these guidelines
for air changes with wall or ceiling exhaust fans: kitchen,
15 changes an hour; bathroom, 8; family, recreation or
laundry room, 6.
To calculate the CFM capacity of wall or ceiling fan which
will deliver the needed air movement, multiply
floor area by the appropriate factor, as follows (assuming
an 8-foot ceiling): kitchen, 2; bathroom, 1.07; family,
recreation or laundry room, 0.8.
A different basis for selection applies to range hood fans.
Recommended minimums: 40 CFM per lineal foot of
range hood for along-wall placement. Higher ratings than
minimums often are desirable.
The recommended
minimum capacity for
whole-house fans is
based on the HVI
guideline, which
requires one complete
air change every two minutes within the occupied area.
This may be determined by multiplying the gross square
footage of the entire house (including non-occupied areas
like closets) by 3. Be sure to include the "upstairs" area of
multilevel homes. This formula assumes an 8' ceiling and
offsets typical non-occupied areas.
VENTILATION
GUIDELINES
For powered attic space ventilators, HVI guidelines are
minimum of 0.7 CFM per square foot of attic floor space,
plus 15% for dark roofs, and intake area of 1 square foot
of free opening per 300 CFM of fan capacity. Ratings are
based on testing of complete roof or gable units at .03"
static pressure.
WHAT’S A SONE?
The sone is an internationally recognized unit of loudness, which simplifies reporting of sound output. The sones translate laboratory decibel
readings into numbers that correspond to the way people sense loudness.
Sones follow a “linear” scale, like inches. Double the sone is double the loudness. In contrast, decibels follow a “logarithmic” scale, which stands
for a complete multiplying of numbers instead of simple adding. Sone readings offer easy, quick and accurate comparisons for both laymen and
engineers. In technical terms, the sone is equal is loudness to a pure tone of 1,000 cycles per second at 40 decibels above the listener’s
threshold of hearing. In everyday terms, one sone is equivalent to the sound of a quiet refrigerator in a quiet kitchen.
Regarding sound levels of Exterior Mount and In-line Fans, and HRV’s/ERV’s:
HVI, the Home Ventilating Institute, does not certify Sound Ratings for Exterior Mount and In-line fans, and Heat/Energy Recovery Ventilators.
Remote mounted fans can be extremely quiet if installed properly. Although different fans produce different amounts of sound power, variations
in installation yield significantly greater differences in perceived sound level for remote mounted fans. As is the case with furnaces, rating remote
mount fans for sound does therefore not make sense.
For bathroom and other exhaust or supply air applications using remote mount fans, HVI recommends using insulated flexible ducting (same as
used for HVAC ducting). Insulated flexible ducting has very good noise attenuating properties and minimizes condensation. With eight feet of
insulated flexible duct between the ceiling grill and the fan, almost no fan noise should be evident in the bathroom. Ensure that the ceiling grills
are large enough not to induce significant air noise. For bathroom applications an automatic timer is a recommended in order to keep the fan
from being left on inadvertently.
For range hood exhaust rigid metal duct shall always be used. Rigid ducting does not attenuate sound effectively. With the very powerful remote
mount fans often used for residential range hoods in “professional” style kitchens, a silencer designed for the purpose will significantly lower the
sound level.
CALIFORNIA ENERGY COMMISSION Compliance Statement As of September 1, 2012 Section 1 of this directory has been approved by the California Energy Commission (Commission) for determining compliance with its Appliance Efficiency Regulations (Title 20, California Code of Regulations, Sections 1601‐1608) and its building standards (Title 24, California Code of Regulations, Part 6). UNLESS INDICATED OTHERWISE, any appliance* listed in Section 1 of this directory may be sold, offered for sale, or installed in new construction in California. For appliances manufactured by manufacturers participating in this directory, but who have not given authorization for data submittal to the Commission, this directory cannot be used for determining compliance. For information about such appliances, appliances that are beyond the scope of this directory, or appliances produced by manufacturers who do not participate in this directory, please contact the Commission's Building Standards Hotline at (916) 654‐5106, (800) 772‐3300 (in California only), or [email protected]. Manufacturers granting authorization for data submittal to the Commission as of the publication date of this directory include:  American Aldes Ventilation Corporation  Continental Fan Manufacturing  Delta Products  Fan Am, Inc.  Hangzhou Aupu Bathroom & Kitchen Technology Co. Ltd.  Homewerks Worldwide  Milano Electronics LLC  Orbit Industries  Qingdao Xingbang Electronic Appliances Co. Ltd.  Panasonic Home & Environment Co.  Renewaire LLC  Reversomatic Mfg. Ltd.  Spruce Environmental Technologies  Systemair Inc.  Ventamatic Ltd.  Windridge Fans Corporation Ltd.  Zhongshan Airzone Ventilated Technology *qualifying appliances are limited to the following product categories:  Bathroom exhaust fans  Other room/utility room exhaust fans  Inline fans  Kitchen range hoods  Whole house comfort ventilators Rev. 09/01/2012
Section 1-1
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
Remote Exteriror Mounted Ventilators
Bathroom – Exhaust Fans (all models)
DELUX80
LIGHT5070
LIGHT80110
LS+
LS+
HS+
HS+
LS+
LS+
HS+
HS+
80
0.9
45.8
80
50
110
90
0.9
35.2
2.0
40.7
0.6
22.1
2.0
27.1
1.1
33.9
2.0
38.6
50
1.5
19.4
60
40
1.2
17.5
@ 0.25” SP
70
60
1.0
@ 0.25” SP
120
100
1.5
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
80
60
110
90
PUFF60
SILENT70
VOLO120
EC90
EC200
90
200
37.6
39.7
ACME ENGINEERING AND MANUFACTURING CORPORATION
AERO PURE
Bathroom – Exhaust Fans (all models)
AP50G2
AP50G3
AP50G4
AP50G5
AP50G6
HS+
80
60
0.3
80
50
1.1
@ 0.25” SP
90
67
0.3
@ 0.25” SP
110
87
0.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
150
131
1.1
41.2
@ 0.25” SP
VQ080ESL
VQ090ES
VQ110ES
VQ120ES
VQ150ES
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
Pascals (Pa) = in. wg x 250
31.8
28.6
AP70G1
HS+
31.8
35.8
AP70G4
AP70G5
AP70G6
22.2
50
38
1.3
22.2
@ 0.25” SP
50
38
1.3
22.2
@ 0.25” SP
50
38
1.3
22.2
@ 0.25” SP
50
1.2
21.9
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
80
80
80
80
80
100
2.0
2.0
2.0
2.0
2.0
2.0
26.1
26.1
26.1
23.9
26.3
34.7
100
90
70
50
2.0
41.4
1.0
36.4
HS+
HS+
AP70G3
50
38
1.3
@ 0.25” SP
HS+
HS+
Bathroom – Exhaust Fans (all models)
@ 0.25” SP
22.2
HS+
AP50L1
AP70G2
50
38
1.3
@ 0.25” SP
HS+
ACME
VQ080ES
32.3
49.6
Aero Pure
50
30
70
50
PUFF55
** CONVERSIONS:
WATTS
Economizer
Abreezo
LS+
LS+
HS+
HS+
SONES
ACTIVE VENTILATION PRODUCTS.
ABREEZO
DEUCE80110
CFM**
HS+
HS+
HS+
HS+
AP80G1
AP80G6 (S)
AP80G6 (W)
AP80L1
AP80L2
AP100L1
HS+
HS+
HS+
HS+
HS+
HS+
AP100L2
HS+
HS+
LS+
LS+
@ 0.25” SP
@ 0.25” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-2
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
AP110G1
AP110G2
AP110G3
AP110G4
AP110G5
AP110G6
AP110G6 (S)
AP110G6 (W)
STATIC
*
PRESSURE**
CFM**
HS+
110
95
2.0
39.5
2.0
39.5
@ 0.25” SP
110
95
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
110
2.0
2.0
39.5
39.5
HS+
HS+
HS+
HS+
HS+
HS+
HS+
@ 0.25” SP
SBF80G2
@ 0.25” SP
SBF80G3
@ 0.25” SP
SBF80G4
@ 0.25” SP
SBF80G5
@ 0.25” SP
HS+
HS+
SBF80G6
@ 0.25” SP
SBF80G6 (S)
SBF80G6 (W)
SBF80L1
HS+
HS+
HS+
@ 0.25” SP
SBF110G2
@ 0.25” SP
SBF110G3
@ 0.25” SP
SBF110G4
110
85
110
85
110
85
Pascals (Pa) = in. wg x 250
180
240
270
120
350
84.0
85.0
84.0
21.0
162.0
Air-King
Bathroom – Exhaust Fans (all models)
AK50LS
<0.3
22.9
AK55L
AK093
AK65
AK65FL
<0.3
22.9
AK80
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
0.4
0.7
22.9
23.4
23.4
22.9
23.4
23.4
23.7
50
32
0.3
70
70
70
70
5.0
3.5
3.5
3.5
80
63
1.5
27.6
@ 0.25” SP
80
68
1.0
28.1
@ 0.25” SP
80
70
1.5
27.5
@ 0.25” SP
80
68
1.0
28.1
@ 0.25” SP
80
68
1.0
28.3
@0.25” SP
90
78
1.5
29.9
@ 0.25”SP
90
80
1.5
28.9
@ 0.25”SP
@ 0.25”SP
90
80
1.5
1.5
28.9
26.0
100
100
2.5
2.5
37.0
37.0
100
86
50
1.5
29.9
0.5
26.9
1.5
28.0
@ 0.25” SP
22.9
AK80H
AK80-1
AK80LS
AK80LS-1
28.1
AK90
0.7
28.1
AK90-1
0.7
28.1
AK90R
0.7
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
NBQ-COMBI-4
NBQ-COMBI-5
NBQ-COMBI-6
NBQ-125-4
NBQ-325-6
<0.3
110
85
HS+
HS+
HS+
WATTS
Quantum
22.9
@ 0.25” SP
@ 0.25” SP
SONES
AIRIA BRANDS INC.
<0.3
0.7
HS+
HS+
CFM**
AIR KING, LTD.
110
85
SBF110G6
** CONVERSIONS:
80
60
DETAILS
STATIC
*
PRESSURE**
Inline Fans (all models)
@ 0.25” SP
SBF110G5
SBF110G6 (S)
SBF110G6 (W)
SBF110L1
80
60
80
60
80
60
80
60
80
60
80
80
80
80
80
SBF110G1
SBF110G5 (S)
SBF110G5 (W)
WATTS
@ 0.25” SP
SBF80G1
SBF80G5 (S)
SBF80G5 (W)
SONES
MODEL
OR SERIES
28.1
28.1
AK100L
AK100L-1
AK100D
110
110
0.7
0.7
28.1
28.1
110
85
0.7
28.1
110
110
110
0.7
0.7
1.3
28.1
28.1
29.4
HS+
HS+
LS+
@ 0.25” SP
AK110LS
AK110PN
@ 0.25” SP
110
90
100
86
1.5
@ 0.25” SP
130
2.5
HS+
AK130-1
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
26.4
29.9
Rev. 09/01/2012
Section 1-3
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
AK150LS
WATTS
150
116
0.8
@ 0.25” SP
200
185
1.4
62.0
@ 0.25” SP
290
265
3.0
79.9
@ 0.25” SP
AK200LS
AK300LS
AK863FL
AK863L
AK864
AK905
AK917
AK927
AK960
AK965FL
AK965L
AKF50LS
@ 0.25” SP
AKF55
AKF80LS
@ 0.25” SP
AKF80LSL
AKF100D HS+
HS+
LS+
LS+
SONES
@ 0.25” SP
@ 0.25” SP
34.6
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
BFQ80
50
33
0.3
90
100
120
2.5
3.5
4.0
50
38
0.5
28.1
@ 0.25” SP
50
38
0.5
28.1
@ 0.25” SP
70
57
1.5
28.7
@ 0.25” SP
70
57
1.5
28.7
@ 0.25” SP
70
57
1.5
28.7
@ 0.25” SP
80
61
2.0
32.0
@ 0.25” SP
100
70
70
70
70
70
3.5
4.0
4.0
4.0
4.0
4.0
80
49
30
<0.3
28.1
<0.3
24.7
<0.3
28.1
<0.3
24.7
<0.3
28.1
<0.3
24.7
BFQ90
BFQ110
BFQ140
70
5.0
BFQF50M
BFQF70
BFQF70M
26.4
BFQF75
BFQF80
80
70
1.0
80
0.8
100
84
50
33
1.5
29.2
0.3
26.4
@ 0.25” SP
DRLC107
DRLC701
DRLC702
DRLC703
DRLC707
DRLC709
ES80D
100
84
1.5
70
70
70
50
50
60
70
90
120
50
70
90
120
50
70
90
120
2.5
2.5
2.5
3.0
3.0
4.0
4.0
2.5
4.0
3.0
4.0
2.5
4.0
3.0
4.0
2.5
4.0
29.2
HS+
LS+
ES80DG
AKLC701
AKLC702
AKLC703
AS50
AS54
AS60
AS70
AS90
AS120
ASF50
ASF70
ASF90
ASF120
ASLC50
ASLC70
ASLC90
ASLC120
HS+
@ 0.25” SP
LS+
ES80DH
HS+
40.5
@ 0.25” SP
LS+
ES80S
<0.3
28.1
80
49
<0.3
28.1
@ 0.25” SP
80
49
<0.3
28.1
@ 0.25” SP
130
93
50
<0.3
34.9
<0.3
28.4
<0.3
34.9
<0.3
28.4
<0.3
34.9
<0.3
28.4
<0.3
34.9
ES80SH
50
38
0.5
28.1
@ 0.25” SP
1.5
28.7
@ 0.25”SP
70
57
HS+
1.5
@ 0.25” SP
70
57
70
57
1.5
@ 0.25”SP
LS+
ES130DG HS+
BFQ70
@ 0.25” SP
LS+
ES130DH HS+
BFQ70R
BFQ75
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
28.7
@ 0.25” SP
LS+
28.7
ES130S
80
49
30
80
499
ES80SG
ES130D
80
49
30
@ 0.25” SP
@ 0.25” SP
BFQ50
32.0
27.6
@ 0.25” SP
AKF100LS
WATTS
2.0
BFQF50
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
SONES
80
61
@ 0.25” SP
100
100
100
70
70
70
70
70
70
CFM**
HS+
@ 0.25” SP
130
93
50
130
93
50
130
93
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-4
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
ES130SG HS+
SONES
WATTS
130
93
<0.3
@ 0.25” SP
130
93
<0.3
34.9
@ 0.25” SP
0.3
26.4
@ 0.25” sp
50
32
80
68
1.0
@ 0.25” SP
90
78
1.5
29.9
@ 0.25” SP
100
86
50
1.5
29.9
0.5
26.9
1.5
29.9
0.5
26.9
110
94
2.0
34.0
130
2.5
ES130SH HS+
FRAK50LS
FRAK80
FRAK90
FRAK100 HS+
@ 0.25” SP
LS+
FRAK100D HS+
@ 0.25” SP
LS+
FRAK110
@ 0.25” SP
FRAK130
100
86
50
34.9
28.1
MODEL
OR SERIES
DETAILS
AP1030W-500
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
AP1036-300
LS+
300
1.5
95.0
AP1036-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
AP1036W-300
LS+
300
1.5
95.0
AP1036W-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
AP1836-300
HS+
300
1.5
AP1836-500
HS+
LS+
500
300
4.5
1.5
AP1836-600
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
AP1836W-300
LS+
300
1.5
95.0
AP1836W-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
Ver. HS+
Ver. LS+
500
180
5.0
0.8
47.5
APF1030-300
LS+
300
1.5
92.2
APF1030-500
Ver. HS+
Ver. LS+
500
300
4.5
1.5
134
92.2
APF1030-600
HS+
MS+
LS+
LS+
500
370
180
140
5.0
2.5
0.8
48.3
Ver. HS+
Ver. LS+
500
180
5.0
0.8
47.5
APF1036-300
LS+
300
1.5
92.2
APF1036-500
Ver. HS+
Ver. LS+
500
300
4.5
1.5
134
92.2
AP1030W-600
AP1036-600
AP1036W-600
Inline Fans (all models)
AIDB4Y
AIF4X
AIF4Y
AIF6X
AIF6Y
AIF8X
AIF10X
AIK14X
AIK14XF
AIK14XL
AIK16X
AIK24Y
AIK26Y
AIK26YF
AIK26YL
150
90
150
190
230
360
600
90
110
110
200
150
230
230
230
80.0
19.4
80.0
61.0
72.5
123
241
19.4
21.1
21.1
62.0
80.0
71.0
71.0
71.0
Kitchen Range Hoods – Ducted & Convertible
ALI36WH
ALI36SS
ALI36BL
500
500
500
11.0
11.0
11.0
AP1030-300
LS+
300
1.5
95.0
AP1030-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
LS+
300
1.5
95.0
AP1030-600
AP1030W-300
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
AP1836W-600
APF1030
APF1036
@ 0.25” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-5
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
APF1036-600
DETAILS
CFM**
SONES
WATTS
500
370
180
140
5.0
2.5
0.8
Ver. HS+
Ver. LS+
500
180
5.0
0.8
47.5
APF1830-300
Ver. LS+
300
1.5
92.2
APF1830-500
Ver. HS+
Ver. LS+
500
300
4.5
1.5
134
92.2
APF1830-600
HS+
MS+
LS+
500
370
180
5.0
2.5
0.8
Ver. HS+
Ver. LS+
500
180
APF1836-300
LS+
APF1836-500
APF1836-600
APF1830
APF1836
HS+
MS+
LS+
LS+
STATIC
*
PRESSURE**
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
AV1246
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1248
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1303
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1304
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1305
Ver. HS+
Hor. HS+
180
180
7.5
7.0
48.3
AV1306
Ver. HS+
Hor. HS+
180
180
7.5
7.0
5.0
0.8
47.5
AV1308
Ver. HS+
Hor. HS+
180
180
7.5
7.0
300
1.5
92.2
AV1363
MS+
LS+
500
300
4.5
1.5
134
92.2
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1364
HS+
MS+
LS+
LS+
500
370
180
140
5.0
2.5
0.8
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1365
Ver. HS+
Hor. HS+
180
180
7.5
7.0
@ 0.25” SP
@ 0.25” SP
48.3
48.3
AR1303
AR1304
AR1305
AR1306
AR1308
AR1363
AR1364
AR1365
AR1366
AR1368
ARA36GL
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
180
180
180
180
180
180
180
180
180
180
570
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
12.5
AV1366
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1368
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1423
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1424
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1213
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1425
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1214
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1426
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1215
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1428
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1216
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AX1303
Ver. HS+
Hor. HS+
160
160
6.5
6.5
AV1218
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AX1308
Ver. HS+
Hor. HS+
160
160
6.5
6.5
AV1243
Ver. HS+
Hor. HS+
180
180
7.5
7.0
AV1244
Ver. HS+
Hor. HS+
180
180
7.5
7.0
CAN36BL
CAN36CO
CAN36SS
CAN36WH
500
500
500
500
12.5
12.5
12.5
12.5
AV1245
Ver. HS+
Hor. HS+
180
180
7.5
7.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
DS1303
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1304
Ver. HS+
Hor. HS+
200
200
6.5
6.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-6
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DS1305
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1306
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1308
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1363
Ver. HS+
Hor. HS+
200
200
6.5
6.5
Ver. HS+
Hor. HS+
200
200
6.5
6.5
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1366
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DS1368
Ver. HS+
Hor. HS+
200
200
6.5
6.5
DQ1303
Ver. HS+
Hor. HS+
310
300
5.5
5.5
Ver. HS+
Hor. HS+
310
300
5.5
5.5
DQ1305
Ver. HS+
Hor. HS+
310
300
5.5
5.5
DQ1306
Ver. HS+
Hor. HS+
310
300
5.5
5.5
DQ1308
Ver. HS+
Hor. HS+
310
300
5.5
5.5
ES243ADA
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
WATTS
MODEL
OR SERIES
DETAILS
ES303ADA
ES304ADA
DS1364
DS1365
ES305ADA
ES306ADA
ES308ADA
DQ1304
ES363ADA
ES364ADA
ES365ADA
ES244ADA
ES245ADA
ES246ADA
ES248ADA
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
41.3
ES366ADA
41.0
ES368ADA
42.4
ESADPQ30
42.4
ESADPQ36
42.4
41.3
ESAPDQ1308
41.0
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
41.0
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
42.4
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
42.4
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
41.0
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
42.4
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
42.4
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
42.4
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.1
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
41.3
41.3
41.0
41.3
41.0
41.3
41.3
41.0
41.3
41.0
41.3
41.0
42.7
42.4
Rev. 09/01/2012
Section 1-7
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
ESAPDQ1368
ESDQ1243
ESDQ1244
ESDQ1245
ESDQ1246
ESDQ1248
ESDQ1303
ESDQ1304
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1..5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
3.5
1.1
WATTS
MODEL
OR SERIES
DETAILS
ESDQ1365
ESDQ1306
ESDQ1308
ESDQ1363
ESDQ1364
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
SONES
WATTS
270
150
270
150
4.0
1.5
3.5
1.1
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
41.0
ESSEV28S
HS+
MS+
LS+
300
200
140
4.5
2.5
0.7
87.3
65.6
48.3
ESSEV30S
HS+
MS+
LS+
300
200
140
4.5
2.5
0.7
87.3
65.6
48.3
ESVAL30B
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
HS+
MS+
LS+
300
200
120
4.5
2.5
0.8
46.4
42.4
ESDQ1366
41.3
41.0
ESDQ1368
42.4
42.4
41.3
41.0
41.3
42.4
41.3
41.0
41.3
ESVAL30S
41.0
41.3
ESVAL30W
41.0
ESVAL36B
42.7
42.4
42.7
42.4
ESVAL36W
41.3
41.0
GRAN30SS
GRAN36SS
GRAN48SS
IBIZ36GL
600
600
600
570
14.0
14.0
14.0
12.5
41.3
LH30SS
41.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
270
150
270
150
4.0
1.5
4.0
1.5
41.3
41.0
41.3
LH36SS
41.0
MAL36SS
600
41.3
41.0
14.0
42.4
P1030-300
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
CFM**
Ver HS+
Ver. LS+
Hor. HS+
Hor. LS+
42.7
ESVAL36S
ESDQ1305
STATIC
*
PRESSURE**
LS+
300
1.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
95.0
Rev. 09/01/2012
Section 1-8
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
P1030-500
P1030-600
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
MS+
LS+
500
300
4.5
1.5
HS+
MS+
600
500
5.5
4.5
900
1200
900
1200
11.0
15.0
11.0
15.0
WATTS
MODEL
OR SERIES
DETAILS
LS+
300
1.5
P1036-500
MS+
LS+
500
300
4.5
1.5
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
LS+
900
1200
300
11.0
15.0
1.5
95.0
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
900
1200
11.0
15.0
P1036-900
P1036-1200
P1036W-300
P1036W-500
P1036W-600
P1036W-900
P1036W-1200
95.0
LS+
300
1.5
95.0
P1842W-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
900
1200
11.0
15.0
95.0
1.5
95.0
P1836-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
900
1200
11.0
15.0
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
900
1200
11.0
15.0
P1848-900
P1848-1200
P1848W-300
LS+
300
1.5
95.0
P1848W-500
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
95.0
900
1200
250
450
450
11.0
15.0
5.5
11.5
11.5
P1848W-600
P1848W-900
P1848W-1200
SEV24SS-AB
SEV24SS
SEV30SS
Ver. HS+
Hor. HS+
260
250
6.0
5.5
QZ2305
Ver. HS+
Hor. HS+
260
250
6.0
5.5
QZ2306
Ver. HS+
Hor. HS+
260
250
6.0
5.5
QZ2308
Ver. HS+
Hor. HS+
260
250
6.0
5.5
QZ2363
Ver. HS+
Hor. HS+
260
250
6.0
5.5
95.0
QZ2364
Ver. HS+
Hor. HS+
260
250
6.0
5.5
95.0
QZ2365
Ver. HS+
Hor. HS+
260
250
6.0
5.5
95.0
QZ2366
Ver. HS+
Hor. HS+
260
250
6.0
5.5
MS+
LS+
500
300
4.5
1.5
95.0
HS+
MS+
LS+
600
500
300
5.5
4.5
1.5
LS+
900
1200
300
11.0
15.0
1.5
MS+
LS+
HS+
MS+
LS+
500
300
600
500
300
4.5
1.5
5.5
4.5
1.5
900
1200
11.0
15.0
Pascals (Pa) = in. wg x 250
500
300
QZ2304
P1836W-500
** CONVERSIONS:
MS+
LS+
95.0
95.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
P1848-500
6.0
5.5
1.5
P1842-900
P1842-1200
95.0
260
250
300
P1842-600
1.5
Ver. HS+
Hor. HS+
LS+
P1842-500
300
QZ2303
P1836W-300
P1836W-900
P1836W-1200
P1842-300
LS+
P1848-600
300
P1836W-600
P1848-300
95.0
LS+
P1836-900
P1836-1200
WATTS
95.0
P1836-300
P1836-600
SONES
P1842W-300
P1842W-900
P1842W-1200
P1036-300
P1036-600
CFM**
95.0
P1842W-600
P1030-900
P1030-1200
P1030W-900
P1030W-1200
STATIC
*
PRESSURE**
95.0
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-9
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
QZ2368
DETAILS
STATIC
*
PRESSURE**
CFM**
Ver. HS+
Hor. HS+
SONES
260
250
6.0
5.5
500
500
500
500
500
500
11.0
11.0
11.0
11.0
11.0
11.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
VH1306
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
VH1308
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
VH1364
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
VH1365
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
8.5
2.0
8.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
300
100
380
100
VAL30BL
VAL30SS
VAL30WH
VAL36BL
VAL36SS
VAL36WH
VH1303
VH1304
VH1305
VH1363
VH1366
VH1368
180
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
AIR KING, LTD.
Rona
Bathroom – Exhaust Fans (all models)
BFQ70R
BFQ75
@ 0.25”SP
BFQ115
70
1.5
28.7
70
57
1.5
28.7
100
3.0
AIR TECH EQUIPMENT, LTD.
Humidex
Other Rooms – Exhaust Fans (all models)
AGV-100-26-150 26” (1 piece model)
90
Designed for apartments and condominiums
2.0
BV-100-30-190
30” (1 piece model)
Crawl Space Model
180
4.0
BV-100-30-250
87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
240
7.0
BV-100-51-190
51” (1 piece model)
Designed for 4’ Basement
180
4.0
BV-100-102-190 87.5” – 103” (2 piece telescopic unit)
Designed for 8’ Basement
180
4.0
BV-100-102-250 87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
240
7.0
HCV-96
87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
240
7.0
HDS-103
30” (1 piece model)
Crawl Space Model
240
7.0
HDS-105
51” (1 piece model)
Designed for 4’ Basement
240
7.0
8.5
2.0
8.0
1.5
HDS-209
87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
30” (1 piece model)
Crawl Space Model
240
7.0
180
4.0
8.5
2.0
8.0
1.5
UNS-105
51” (1 piece model)
Designed for 4’ Basement
180
4.0
UNS-209
87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
180
4.0
WV-SCBT
87.5” – 103” (2 piece Telescopic Unit)
Designed for 8’ Basement
240
7.0
Other Rooms – Exhaust Fans (all models)
EWF180
WATTS
MODEL
OR SERIES
UNS-103
6.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
18.0
Rev. 09/01/2012
Section 1-10
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
AIR ZONE FANS INC.
MODEL
OR SERIES
DETAILS
A-12HP
PA1100V
110
87
1.0
26.2
@ 0.25” SP
110
88
1.0
26.0
@ 0.25” SP
PA1100VLE
AMERICAN ALDES VENTILATION CORPORATION
Inline Fans (all models)
A-4
@ 0.2” SP
@ 0.4” SP
@ 0.6” SP
110
83
55
20.7
20.2
19.0
A-4HP
@ 0.2” SP
@ 0.4” SP
@ 0.6” SP
150
134
119
71.0
70.0
69.0
A-5
@ 0.2:SP
@ 0.4” SP
@ 0.6” SP
130
99
66
20.4
21.2
20.3
@ 0.2” SP
@ 0.4” SP
@ 0.6” SP
190
160
112
73.0
72.0
68.0
A-6
@ 0.2” SP
@ 0.4” SP
@ 0.6” SP
270
232
164
73.6
75.3
74.2
A-6HP
@ 0.2” SP
@ 0.4” SP
@ 1.25” SP
450
409
243
157
160
158
@ 0.2” SP
@ 0.4” SP
@ 0.8” SP
410
351
243
121
124
128
A-8HP
@ 0.2” SP
@ 0.6” SP
@ 1.25” SP
470
388
266
145
156
159
A-10
@ 0.2” SP
@ 0.6” SP
@ 1.25” SP
480
407
269
141
153
158
A-10HP
@ 0.2” SP
@ 0.8” SP
@ 1.75” SP
560
472
306
200
211
209
A-12
@ 0.2” SP
@ 0.8” SP
@ 1.25” SP
680
433
290
184
204
203
A-8
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
SONES
BVS 120
BVS 200
DSVS 100
FSVS 100
MPVS 100
MPVS 120
MPVS 150
MPVS 200
VS-4
VS-4MAX
VS-6
VS-6MAX
WATTS
880
670
504
306
326
330
150
230
110
110
80
120
170
250
80
120
170
260
42.5
65.9
37.5
37.3
21.2
37.6
41.3
62.5
21.6
38.4
40.1
63.2
120
180
220
360
410
18.0
92.0
92.0
149.0
151.0
Remote Exterior Mounted Ventilators
American Aldes
A-5HP
CFM**
@ 0.2” SP
@ 0.8” SP
@ 1.25” SP
Airzone
Bathroom – Exhaust Fans (all models)
STATIC
*
PRESSURE**
XMVA4
XMVA4HP
XMVA6
XMVA6HP
XMVA8HP
BROAN –NUTONE LLC
Aira (Canada)
Bathroom – Exhaust Fans (all models)
VSBP50M
VSBP90M
50
90
3.0
2.5
180
180
210
7.5
7.0
7.0
Kitchen Range Hoods – Ducted & Convertible
HFRM
Ver. HS+
Hor. HS+
7” Ver. Rd. HS+
BROAN –NUTONE LLC
Best
Kitchen Range Hoods – Ducted & Convertible
CC34ISB
Hor. HS+
Hor. WS+
@ 0.021” SP
500
220
8.5
3.0
CP34I309SB
Ver. HS+
Ver. LS+
290
130
11.5
3.0
CP34I369SB
Ver. HS+
Ver. LS+
290
130
11.5
3.0
CP34I429SB
Ver. HS+
Ver. LS+
290
130
11.5
3.0
CP35I309SB
Ver. HS+
Ver. LS+
600
190
12.0
2.0
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-11
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
CP35I369SB
Ver. HS+
Ver. LS+
600
190
12.0
2.0
CP35I429SB
Ver. HS+
Ver. LS+
600
190
12.0
2.0
CP37I482SB
Ver. HS+
Ver. LS+
1200
380
13.5
2.0
CP45I362SB
Ver. HS+
Ver. LS+
600
210
8.5
1.1
CP45I369SB
Ver. HS+
Ver. LS+
600
210
8.5
1.1
CP45I489SB
Ver. HS+
Ver. LS+
600
210
8.5
1.1
CP47I362SB
Ver. HS+
Ver. LS+
1000
370
12.0
1.5
CP47I422SB
Ver. HS+
Ver. LS+
1000
370
12.0
1.5
CP47I482SB
Ver. HS+
Ver. LS+
1080
410
10.5
1.5
CP47I542SB
Ver. HS+
Ver. LS+
1110
420
10.5
1.5
CP47I602SB
Ver. HS+
Ver. LS+
1110
420
10.5
1.5
CP47I662SB
Ver. HS+
Ver. LS+
1110
420
10.5
1.5
CPDI362SB
Ver. HS+
Ver. WS+
@ 0.022” SP
1040
480
11.5
3.0
Ver. HS+
Ver. WS+
@ 0.022” SP
1040
480
11.5
3.0
Ver. HS+
Ver. WS+
@ 0.022” SP
1040
480
11.5
3.0
Ver. HS+
Ver. LS+
450
190
8.5
2.5
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
IS4290X130CMSS Ver. HS+
IS102SS
Ver. HS+
IS170SS
Ver. HS+
BER02ISSS
Ver. HS+
500
500
500
1000
1000
1000
450
500
8.5
8.5
8.5
11.5
11.5
12.0
8.0
9.0
CPDI482SB
CPDI602SB
IBF4I36SB
IS23BL
IS23SS
IS23WH
IS4270X100SS
IC35I90B
Ver. HS+
Ver. WS+
490
220
7.0
2.5
IC35I90W
Ver. HS+
Ver. WS+
490
220
7.0
2.5
IM33I45SP
Ver. HS+
Ver. WS+
400
200
7.0
3.0
IS502SS
Ver. HS+
450
8.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
ISER222SS
K1590CMSS
K2948SS
K2990CMSS
K3090CMSS
K3048SS
K3490CMSS
K4130SS
K4136SS
K4236SS
K4242SS
K4248SS
K4254SS
K27342SS
K27390CMSS
K313930BL
K313930SS
K313936BL
K313936SS
K313942SS
K350090CMSS
K738890CMSS
K778836SS
K778836SSB
K778836SSC
K778836SSR
K808730SS
K808736SS
KER22242SS
KER22248SS
KER22290CMSS
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
1000
500
500
500
500
500
500
500
500
1000
1000
1000
1000
500
500
400
400
400
400
400
450
450
440
440
440
440
450
450
1000
1000
1000
10.0
9.5
8.5
8.5
8.5
8.5
9.5
8.0
8.0
10.0
10.0
10.0
10.0
9.5
9.5
6.0
6.0
6.0
6.0
6.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
10.0
10.0
10.0
P5
Ver. HS+
Hor. HS+
460
500
10.5
10.0
P6
Ver. HS+
600
8.5
P8
Ver. HS+
Hor. HS+
850
900
10.5
10.0
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
P1952M70CMBL Ver. HS+
P1952M70CMSS Ver. HS+
PK2229
Ver. HS+
PK2238
Ver. HS+
U10230BLI
Ver. HS+
U10230SBI
Ver. HS+
U10236BLI
Ver. HS+
U10236SBI
Ver. HS+
1200
1200
450
450
450
450
800
800
1000
1000
500
500
500
500
11.0
12.0
7.5
7.5
7.5
7.5
10.0
10.0
10.5
10.5
10.0
10.0
10.0
10.0
P12
P12D
P1951M52CMBL
P1951M52CMSS
P1951M70CMBL
P1951M70CMSS
UP27I30SB
Ver. 3x10
Ver. 3x14
Hor. 3x10
Hor. 3x14
550
600
650
700
8.5
8.5
8.5
8.5
UP27I36SB
Ver. 3x10
Ver. 3x14
Hor. 3x10
Hor. 3x14
550
600
650
700
8.5
8.5
8.5
8.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-12
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
UP27I42SB
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
Ver. 3x10
Ver. 3x14
Hor. 3x10
Hor. 3x14
550
600
650
700
8.5
8.5
8.5
8.5
Ver. 3x10
Ver. 3x14
Hor. 3x10
Hor. 3x14
550
600
650
700
8.5
8.5
8.5
8.5
WBF4I30SB
Ver. HS+
Ver. LS+
450
190
8.5
2.5
WBF4I36SB
Ver. HS+
Ver. LS+
450
190
8.5
2.5
WC23I90CBG
Ver. HS+
Ver. LS+
410
110
9.0
1.0
WC23I90SBG
Ver. HS+
Ver. LS+
410
110
9.0
1.0
WT32I362SB
Ver. HS+
Ver. LS+
480
130
9.5
1.0
Ver. HS+
Ver. LS+
480
130
Ver. HS+
Ver. LS+
WC26I42SB
WC26I48CB
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
WM34I80SB
Ver. HS+
Ver. WS+
490
220
7.5
2.0
WM43I80SB
Ver. HS+
Ver. WS+
490
220
7.5
2.0
WM45I80SB
Ver. HS+
Ver. WS+
460
210
8.5
2.5
WPD38I36SB
Ver. HS+
Ver. WS+
1160
430
11.0
2.0
WPD38I48SB
Ver. HS+
Ver. WS+
1160
430
11.0
2.0
WPD38I60SB
Ver. HS+
Ver. WS+
1160
430
11.0
2.0
WT32I302SB
Ver. HS+
Ver. WS+
Ver. HS+
Ver. WS+
600
200
600
200
9.5
1.4
9.5
1.4
WT32I422SB
Ver. HS+
Ver. WS+
600
200
9.5
1.4
9.5
1.0
WT32I482SB
Ver. HS+
Ver. WS+
1200
400
12.0
2.0
480
130
9.5
1.0
Downdraft Kitchen Exhausters
Ver. HS+
Ver. LS+
480
130
9.5
1.0
Ver. HS+
Ver. LS+
480
130
9.5
1.0
WC26I48SB
Ver. HS+
Ver. LS+
480
130
9.5
1.0
ILB3
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
260
280
WC33I90SB
Ver. HS+
Ver. WS+
490
220
7.5
2.0
ILB6
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
600
600
WC34I90SB
Ver. HS+
450
9.0
ILB9
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
700
800
WC35I90SB
Ver. HS+
450
9.0
ILB11
WC43I80B
Ver. HS+
Ver. WS+
490
220
7.5
3.0
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
1000
1100
WC43I80W
Ver. HS+
Ver. WS+
490
220
7.5
3.0
EB6
@ 0.03” SP
@ 0.10” SP
640
600
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
530
140
540
150
8.5
1.0
9.0
1.0
EB9
@ 0.03” SP
@ 0.10” SP
940
900
EB12
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
530
140
540
150
8.5
1.0
9.0
1.0
@ 0.03” SP
@ 0.10” SP
1230
1200
EB15
@ 0.03” SP
@ 0.10” SP
1530
1500
Ver. HS+
Ver. WS+
400
200
7.0
3.0
UP27I48SB
WC26I36CB
WC26I36SB
WC26I42CB
DD0130SS
DD0136SS
DD0148SS
Ver. HS+
Ver. HS+
Ver. HS+
500
500
500
Inline Fans (all models)
Remote Exterior Mounted Ventilators
WM24I36AM
WM24I48AM
WM33I40R
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-13
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
BROAN –NUTONE LLC
MODEL
OR SERIES
761WHA
764BN
764RB
764WH
766BN
766RB
Broan
Bathroom – Exhaust Fans (all models)
100
85
2.0
70.2
66.0
770
@ 0.25” SP
100
85
2.0
70.2
66.0
771
@ 0.25” SP
70
70
50
70
70
70
70
50
50
70
70
60
110
110
110
3.5
3.5
1.5
4.0
4.0
4.0
4.0
2.5
3.5
6.0
6.0
4.5
4.0
4.0
4.0
50
39
2.5
679
679L
680
683
683L
70
70
100
80
80
3.5
3.5
4.0
2.5
2.5
684
80
68
2.5
3.0
50
60
60
100
70
70
4.0
5.5
3.0
4.5
3.5
3.5
70
55
1.5
34.4
32.3
QT90E
@ 0.25” SP
70
55
1.5
34.4
32.3
QT90L
@ 0.25” SP
70
55
1.5
34.4
32.3
QT110E
@ 0.25” SP
100
100
70
70
3.5
3.5
3.5
3.5
80
67
2.5
80
80
2.5
2.5
100HL
100HFL
162
164
576
655
655MX
657
658
659
670
671
671MX
673
674
676
676MX
678
@ 0.25” SP
@ 0.25” SP
688
689
690
696
741SN
741WH
744
744FL
744SFL
750
751
754RB
754SN
757SN
@ 0.25” SP
761BN
761RB
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
DETAILS
STATIC
*
PRESSURE**
17.8
50
35
1.5
70
4.0
80
68
2.0
24.9
@ 0.25” SP
80
65
2.0
26.1
@ 0.25” SP
50
38
1.5
27.1
@ 0.25” SP
50
38
1.5
27.1
@ 0.25” SP
50
38
1.5
@ 0.25” SP
27.0
25.1
80
67
2.5
@ 0.25” SP
29.0
27.8
80
65
2.5
@ 0.25” SP
49.0
48.0
70
60
50
6.0
4.5
2.5
1.1
25.6
1.3
25.7
@ 0.25”SP
80
60
70
55
80
55
0.8
28.4
@ 0.25” SP
@ 0.25” SP
80
55
0.8
1.0
28.4
28.1
90
72
1.5
36.3
@ 0.25” SP
90
72
1.5
@ 0.25” SP
36.3
36.2
110
90
1.0
36.3
@ 0.25”SP
110
90
1.0
36.3
@ 0.25”SP
130
116
130
114
2.0
48.3
1.5
49.0
778WH
784
HD50=RDH with HD50RDF
HD50L
HD80
HD80L
L671M
L673M
L678M
LP80
4” Duct
@ 0.25” SP
3” Duct
QT80E
QT80L
QT110LE
QT130E
29.0
27.8
4” Duct
4” Duct
6” Duct
6” Duct
WATTS
2.5
2.5
2.5
2.5
2.5
2.5
@ 0.25” SP
49.0
45.3
SONES
80
80
80
80
80
80
HD50
42.4
41.6
CFM**
@ 0.25” SP
@ 0.25” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
17.8
Rev. 09/01/2012
Section 1-14
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
QT130LE 4” Duct
4” Duct
6” Duct
6” Duct
QT140E
STATIC
*
PRESSURE**
CFM**
@ 0.25” SP
@ 0.25” SP
4” duct
4” duct
6” duct
6” duct
@ 0.25” SP
@ 0.25” SP
QT140LE 4” duct
4’ duct
6” duct
6” duct
SONES
130
116
130
114
130
116
140
123
WATTS
2.0
48.3
1.5
49.0
2.0
48.3
1.5
49.0
2.0
46.4
1.5
47.4
MODEL
OR SERIES
DETAILS
36.3
QTRE110FLT
110
90
1.3
36.3
@ 0.25” SP
QTRE110FLT=QTXR000HL with QTRE110FLFT
@ 0.25” SP
110
90
1.3
36.3
QTRE110RF
110
90
1.3
36.3
@ 0.25” SP
110
82
0.9
@ 0.25” SP
42.8
41.7
110
84
0.9
@ 0.25 “ SP
42.8
41.7
110
90
0.9
@ 0.25 “ SP
33.5
33.0
50
31
<0.3
19.6
@ 0.25 “ SP
80
55
0.3
23.3
@ 0.25 “ SP
80
55
0.3
23.3
@ 0.25 “ SP
110
90
0.7
33.5
@ 0.25 “ SP
110
90
0.7
33.5
@ 0.25 “ SP
110
90
0.7
33.5
@ 0.25 “ SP
110
90
0.7
@ 0.25 “ SP
33.5
33.0
150
118
1.4
51.3
@ 0.25 “ SP
150
118
1.4
51.3
@ 0.25 “ SP
80
55
0.3
23.3
@ 0.25 “ SP
110
90
0.7
33.5
@ 0.25 “ SP
50
49
50
50
<0.3
4.9
<0.3
5.1
50
48
50
50
<0.3
4.9
<0.3
5.3
50
28
0.4
80
66
1.0
@ 0.25” SP
80
66
1.0
@ 0.25” SP
110
98
1.5
@ 0.25” SP
110
98
1.5
@ 0.25” SP
6” Duct
4” Duct
140
130
2.0
2.5
QTXE110
6” Duct
4” Duct
140
130
2.0
2.5
QTXE110FLT
80
55
0.8
@ 0.25 “ SP
QTRE080=QTXR000HF with QTRE080F
@ 0.25 “ SP
80
55
0.8
QTRE080C2S
80
56
40
0.8
QTR080L
QTR110
QTR110L
QTR140
QTR140L
QTRE080
HS+
HS+
LS+
@ 0.25” SP
QTX110HFLT
26.8
26.6
QTX110HL
56.6
57.8
QTX110SL
56.6
57.8
QTXE050
70.5
69.2
QTXE080
70.5
69.2
QTXE080FLT
28.4
28.4
24.8
<0.3
12.9
0.8
28.4
@ 0.25 “ SP
80
55
QTRE080FLT=QTXR000HL with QTRE080FLFT
@ 0.25” SP
80
55
0.8
28.4
QTRE080R
0.8
28.4
@ 0.25” SP
80
55
0.8
28.4
@ 0.25” SP
80
55
QTXE110S
QTXE110SFLT
QTXE150
QTXE150FLT
QTRE080FLT
SSQTXE080
SSQTXE110
XB50
QTRE080RF
6” Rd. Duct
@ 0.25 “ SP
4” Duct
@ 0.25” SP
QTRE100S
@ 0.25 “ SP
100
81
1.5
36.3
XB50L
6” Rd. Duct
@ 0.25” SP
QTRE100S=HQT54 with FQTRE110S
@ 0.25 “ SP
100
81
1.5
QTRE110
110
90
1.3
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
1.3
@ 0.25” SP
QTR080
SONES
110
90
@ 0.25” SP
QTR050F
CFM**
QTRE110=QTXR000HF with QTRE110F
@ 0.25” SP
130
112
140
122
@ 0.25” SP
STATIC
*
PRESSURE**
36.3
4” Duct
@ 0.25” SP
36.3
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-15
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
XB80
DETAILS
STATIC
*
PRESSURE**
CFM**
6” Rd. Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
SONES
WATTS
80
79
80
80
<0.3
5.8
80
80
60
63
<0.3
6.0
<0.3
6.4
MODEL
OR SERIES
ZB110
DETAILS
STATIC
*
PRESSURE**
Airflow rate setting 110
@ 0.25” SP
0.3
7.6
Airflow rate setting 100
@ 0.25” SP
Airflow rate setting 90
XB80L
6” Rd. Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
XB110
6” Rd. Duct
110
110
<0.3
@ 0.25” SP
<0.3
@ 0.25” SP
110
110
7.7
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
XB110L
6” Rd. Duct
8.7
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
ZB80
6” Rd. Duct
Airflow rate setting 80
Airflow rate setting 30
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
80
79
70
71
60
61
50
49
40
36
30
23
<0.3
5.8
<0.3
5.1
@ 0.25” SP
ZB110L
Airflow rate setting 110
@ 0.25” SP
<0.3
4.4
Airflow rate setting 100
@ 0.25” SP
<0.3
4.0
Airflow rate setting 90
@ 0.25” SP
<0.3
3.7
Airflow rate setting 80
@ 0.25” SP
<0.3
3.4
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
ZB80
4” Duct
Airflow rate setting 80
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
ZB80L
6” Rd. Duct
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
ZB80L
4” Duct
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
80
80
70
70
60
60
50
47
40
34
30
22
80
80
70
70
60
60
50
50
40
40
30
30
60
63
50
54
40
43
30
30
0.3
7.6
Airflow rate setting 50
@ 0.25” SP
<0.3
6.5
Airflow rate setting 40
@ 0.25” SP
<0.3
5.5
Airflow rate setting 30
@ 0.25” SP
<0.3
5.1
<0.3
4.3
<0.3
3.9
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
<0.3
6.4
<0.3
5.6
<0.3
4.9
<0.3
4.4
CFM**
SONES
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
WATTS
<0.3
7.7
<0.3
7.0
<0.3
6.4
<0.3
5.8
<0.3
5.1
<0.3
4.6
<0.3
4.1
<0.3
3.7
<0.3
3.3
<0.3
8.7
<0.3
7.3
<0.3
6.5
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
Downdraft Kitchen Exhausters
273003
273603
RMDD3004
RMDD3604
RMDD4804
500
500
500
500
500
Inline Fans (all models)
MP100
@ 0.20” SP
@ 0.40” SP
110
98
MP140
@ 0.20” SP
@ 0.40” SP
150
141
MP200
@ 0.20” SP
@ 0.40” SP
210
200
MP280
@ 0.20” SP
@ 0.40” SP
290
265
HLB3
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
260
280
HLB6
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
600
600
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-16
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
HLB9
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP
HLB11
Ver. HS+
Hor. HS+
@ 0.20” SP
@ 0.20” SP 1100
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
700
800
403001
Ver. HS+
Hor. HS+
160
160
6.5
6.5
1000
403002
Ver. HS+
Hor. HS+
160
160
6.5
6.5
SP100
@ 0.20” SP
@ 0.40” SP
110
97
403004
Ver. HS+
Hor. HS+
160
160
6.5
6.5
SP140
@ 0.20” SP
@ 0.40” SP
150
133
403008
Ver. HS+
Hor. HS+
160
160
6.5
6.5
SP200
@ 0.20” SP
@ 0.40” SP
210
195
403023
Ver. HS+
Hor. HS+
160
160
6.5
6.5
403601
Ver. HS+
Hor. HS+
160
160
6.5
6.5
403602
Ver. HS+
Hor. HS+
160
160
6.5
6.5
403604
Ver. HS+
Hor. HS+
160
160
6.5
6.5
403608
Ver. HS+
Hor. HS+
160
160
6.5
6.5
403623
Ver. HS+
Hor. HS+
160
160
6.5
6.5
404201
Ver. HS+
Hor. HS+
160
160
6.5
6.5
Kitchen - Exhaust Fans
12C
502
503
504
505
506
507
508
509
509S
509SMX
L509SM
370
270
160
350
180
470
250
270
180
180
180
180
8.0
8.0
5.0
6.5
6.5
8.0
7.0
6.0
6.5
6.5
6.5
6.5
Kitchen Range Hoods – Ducted & Convertible
103023
Ver. HS+
Hor. HS+
360
360
5.0
4.5
404202
Ver. HS+
Hor. HS+
160
160
6.5
6.5
Ver. HS+
Hor. HS+
360
360
4.5
4.5
404208
Ver. HS+
Hor. HS+
160
160
6.5
6.5
153001
153004
153023
153601
153604
153623
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
300
300
300
300
300
300
4.5
4.5
4.5
4.5
4.5
4.5
402101
Ver. HS+
Hor. HS+
160
160
6.5
6.5
402102
Ver. HS+
Hor. HS+
160
160
6.5
6.5
402108
Ver. HS+
Hor. HS+
160
160
6.5
6.5
402401
Ver. HS+
Hor. HS+
160
160
6.5
6.5
402402
Ver. HS+
Hor. HS+
160
160
6.5
6.5
402404
Ver. HS+
Hor. HS+
160
160
6.5
6.5
422401
422401D
422402
422404
422408
423001
423001D
423002
423004
423008
423008D
423023
423601
423601D
423602
423604
423608
423608D
423623
424201
424201D
424202
424204
424208
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
402408
Ver. HS+
Hor. HS+
160
160
6.5
6.5
433004
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
113023
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-17
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
433011
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463023
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433018
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463601
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433022
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463602
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433023
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463604
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433604
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463608
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433611
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
463623
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433618
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
464201
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433622
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
464202
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
433623
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
160
220
7.0
7.0
8.0
464204
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
462401
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
464208
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
462404
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
462423
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
463001
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
523001
523002
523008
523601
524201
613004
614804
619004
637004
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
100
100
100
100
100
450
900
450
900
8.0
8.0
8.0
8.0
8.0
9.0
9.5
9.0
9.5
883001
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
883002
Ver. HS+
Hor. HS+
360
350
5.5
6.0
463004
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
7.5
7.5
7.5
883004
Ver. HS+
Hor. HS+
360
350
5.5
6.0
883008
463008
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
Ver. HS+
Hor. HS+
7” Rd.Ver. HS+
190
190
220
190
190
220
7.5
7.5
7.5
7.5
7.5
7.5
Ver. HS+
Hor. HS+
360
350
5.5
6.0
883011
Ver. HS+
Hor. HS+
360
350
5.5
6.0
463002
463011
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-18
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
883022
Ver. HS+
Hor. HS+
360
350
5.5
6.0
893904
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883023
Ver. HS+
Hor. HS+
360
350
5.5
6.0
894201
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883601
Ver. HS+
Hor. HS+
360
350
5.5
6.0
894204
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883604
Ver. HS+
Hor. HS+
360
350
5.5
6.0
894223
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883608
Ver. HS+
Hor. HS+
360
350
5.5
6.0
894801
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883623
Ver. HS+
Hor. HS+
360
350
5.5
6.0
894804
Ver. HS+
Hor. HS+
460
440
6.0
7.0
883901
Ver. HS+
Hor. HS+
360
350
5.5
6.0
AP130BL
883904
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
AP130SS
884201
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
884204
Ver. HS+
Hor. HS+
360
350
5.5
6.0
AP130WW
884223
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
884801
Ver. HS+
Hor. HS+
360
350
5.5
6.0
AP136BL
884804
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
AP136SS
884823
Ver. HS+
Hor. HS+
360
350
5.5
6.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS
440
120
440
130
7.0
0.5
7.0
0.5
893001
Ver. HS+
Hor. HS+
460
440
6.0
7.0
AP136WW
893004
Ver. HS+
Hor. HS+
460
440
6.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
893011
Ver. HS+
Hor. HS+
460
440
6.0
7.0
APE130SS
893023
Ver. HS+
Hor. HS+
460
440
6.0
7.0
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
440
200
440
200
7.0
0.7
7.0
0.9
160
70.1
162
70.2
893601
Ver. HS+
Hor. HS+
460
440
6.0
7.0
893604
Ver. HS+
Hor. HS+
460
440
6.0
7.0
893623
Ver. HS+
Hor. HS+
460
440
6.0
7.0
893901
Ver. HS+
Hor. HS+
460
440
6.0
7.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
@ 0.023” SP
@ 0.020” SP
B3030SS
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
300
120
270
120
270
120
6.0
1.0
6.0
0.8
6.0
0.8
84.3
57.8
83.7
58.5
82.4
58.0
B3036SS
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
300
120
270
120
270
120
6.0
1.0
6.0
0.8
6.0
0.8
84.3
57.8
83.7
58.5
82.4
58.0
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-19
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
B5630SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5636SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5730SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5736SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5830SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5836SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
B5936SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
E5490SS
Ver. HS+
Ver. LS+
480
230
9.5
3.0
E6030SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6036SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6042SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6042TSS
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E6048SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6048TSS
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
E6430SS
E6436SS
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
E6442SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
E6448SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
E6448TSS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E66130BL
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66130SS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66130WW
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66136BL
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66136SS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66136WW
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E66142SS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
550
290
120
600
310
130
8.5
2.5
0.4
8.5
2.5
<0.3
E5590SS
Ver. HS+
Ver. LS+
360
140
6.5
0.7
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-20
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
EI5936SS
DETAILS
CFM**
SONES
500
200
10.5
2.5
Ver. HS+
Ver. WS+
1160
430
11.0
2.0
EPD6148SS
Ver. HS+
Ver. WS+
1160
430
11.0
2.0
EW5630SS
Ver. HS+
Ver. WS+
@ 0.004” SP
500
200
10.5
2.5
Ver. HS+
Ver. WS+
@ 0.004” SP
500
200
10.5
2.5
Ver. HS+
Ver. WS+
@ 0.004” SP
500
200
10.5
2.5
Ver. HS+
Ver. WS+
@ 0.004” SP
500
200
10.5
2.5
EPD6136SS
EW5636SS
EW5830SS
EW5836SS
Ver. HS+
Ver. WS+
STATIC
*
PRESSURE**
@ 0.004” SP
WATTS
MODEL
OR SERIES
6.5
6.5
6.5
F403022
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403023
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403601
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403602
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403604
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403608
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403611
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403622
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403623
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404201
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404202
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404204
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404208
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404211
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
160
160
190
6.5
6.5
6.5
6.5
6.5
6.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
6.5
6.5
6.5
F402402
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F402404
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F402408
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F402411
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F402422
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F402423
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403001
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403002
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F403004
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404222
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
160
160
190
6.5
6.5
6.5
F404223
Pascals (Pa) = in. wg x 250
WATTS
160
160
190
160
160
190
** CONVERSIONS:
SONES
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
CFM**
F403011
F402401
F403008
DETAILS
STATIC
*
PRESSURE**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-21
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
P5
Ver. HS+
Hor. HS+
460
500
10.5
10.0
P8
Ver. HS+
Hor. HS+
850
900
10.5
10.0
PM250
PM390
PM390S
PM390WW
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
250
390
390
390
8.0
6.0
6.0
6.0
PM500SS
PME300
Ver. HS+
Ver. HS+
Ver. WS+
500
290
120
9.0
5.0
0.5
QDE30BL
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7”Rd. Ver. HS+
7”Rd. Ver. WS+ @ 0.039” SP
190
130
190
100
230
150
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7”Rd. Ver. HS+
7”Rd. Ver. WS+ @ 0.039” SP
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
7” Rd. HS+
7” Rd. WS+
QDE30SS
QDE30WW
QL130BC
QL130WW
QML30BL
QML30SS
QML30WW
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
7” Rd. HS+
7” Rd. WS+
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
7” Rd. HS+
7” Rd. WS+
@ 0.038” SP
@ 0.031” SP
@ 0.039” SP
@ 0.038” SP
@ 0.031” SP
@ 0.039” SP
@ 0.038” SP
@ 0.031” SP
@ 0.039” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QP130BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP130SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP130WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP136BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd Ver. HS+
7”Rd Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP136SS
6.0
2.0
6.0
2.0
6.0
2.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP136WW
190
130
190
100
230
150
6.0
2.0
6.0
2.0
6.0
2.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP142BL
200
130
190
100
250
150
5.0
2.0
4.5
1.5
4.5
2.0
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
300
100
280
100
260
90
5.0
0.8
5.0
0.8
5.5
0.8
QP142SS
200
130
190
100
250
150
5.0
2.0
4.5
1.5
4.5
2.0
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
300
100
280
100
260
90
5.0
0.8
5.0
0.8
5.5
0.8
QP142WW
200
130
190
100
250
150
5.0
2.0
4.5
1.5
4.5
2.0
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
300
100
280
100
260
90
5.0
0.8
5.0
0.8
5.5
0.8
282
43.8
36.2
36.2
36.2
36.2
36.2
36..2
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-22
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QP230BC
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP236SS
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP230BL
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP236WW
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP230SS
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP242BC
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP230WW
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP242BL
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP236BC
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP242SS
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP236BL
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
QP242WW
Hor. HS+
Hor. MS+
Hor. WS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
350
240
100
310
220
100
280
200
100
5.0
2.5
0.6
6.0
2.5
0.6
6.0
2.5
0.6
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-23
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QP330BL
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP336WW
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP330SS
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP342BL
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP330WW
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP342SS
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP336BL
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP342WW
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP336SS
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
450
360
230
100
390
320
210
100
340
300
200
100
7.0
4.5
1.5
<0.3
7.5
5.5
2.0
<0.3
7.0
5.5
2.0
<0.3
QP430SS
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
630
470
290
150
570
430
280
160
460
360
230
130
7.5
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-24
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
QP436SS
QP442SS
QS130AA
QS130BC
QS130BL
QS130SS
QS130SSMX
QS130WW
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
630
470
290
150
570
430
280
160
460
360
230
130
7.5
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
Hor. BS+
Hor. HS+
Hor. MS+
Hor. WS+
Ver. BS+
Ver. HS+
Ver. MS+
Ver. WS+
7” Rd. BS+
7” Rd. HS+
7” Rd. MS+
7” Rd. WS+
630
470
290
150
570
430
280
160
460
360
230
130
7.5
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
7.0
4.5
1.5
<0.3
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
220
200
5.5
5.0
5.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QS136AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS136BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS136BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS136SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS136WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS142AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS142BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS142BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS142SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-25
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QS142WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS236SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS236WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS242AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS242BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS242BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS242SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS236AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS242WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS236BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS330AA
QS236BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-26
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QS330BC
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS336BL
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS330BL
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS336SS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS330SS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS336WW
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS330WW
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS342AA
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS336AA
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS342BC
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS336BC
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS342BL
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-27
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
QS342SS
QS342WW
QSE130BL
QSE130SS
QSE130WW
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver.BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
QT230AA
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT230BC
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT230BL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT230SS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT230SSMX
Ver. HS+
Hor. HS+
7” Rd Ver. HS+
180
170
200
5.0
5.0
5.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
MODEL
OR SERIES
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
CFM**
SONES
WATTS
QT236AA
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT236BC
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT236BL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT236SS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT236WW
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT242AA
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT242BC
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT242BL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT242SS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.5
QT242WW
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
170
220
4.5
4.5
4.55
RM325H
RM326H
RM503001
RM503004
RM503023
RM503601
RM503604
RM503623
RM519004
RM523004
RM524204
RM523604
RM533004
RM533604
RM534204
RM659004
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
RME5030SS
Ver. HS+
Ver. WS+
RP130BL
QT230WW
DETAILS
STATIC
*
PRESSURE**
@ 0.013” SP
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
1200
270
270
270
270
270
270
370
370
370
370
370
370
370
450
6.0
12.0
6.5
6.5
6.5
6.5
6.5
6.5
7.0
7.0
7.0
7.0
7.0
7.0
7.0
9.0
290
130
5.5
0.5
440
120
440
130
7.0
0.5
7.0
0.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
295
46.0
Rev. 09/01/2012
Section 1-28
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
RP130SS
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP130WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP136BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP230BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP230SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP236SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP236WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
RP136SS
RP136WW
RP230WW
RP236BL
Other Rooms – Exhaust Fans (all models)
510
511
512
512M
L512M
380
180
90
70
70
6.5
4.5
3.5
3.5
3.5
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
349BR
353 w/ HVI Louver
353 w/ 433 Shutter
355BK
355BR
356BK
356BR
358
35316 w/ HVI Louver
35316 w/ 433 Shutter
@ 0.03” SP
@ 0.03” SP
Pascals (Pa) = in. wg x 250
WATTS
1000
760
1020
1200
1200
1600
1600
1200
1160
1600
Remote Exterior Mounted Ventilators
331H
@ 0.03” SP
@ 0.10” SP
640
600
332H
@ 0.03” SP
@ 0.10” SP
940
900
335
@ 0.03” SP
@ 0.10” SP
1230
1200
336
@ 0.03” SP
@ 0.10” SP
1530
1500
BROAN –NUTONE LLC
Broan (Canada)
Bathroom – Exhaust Fans (all models)
162
164
683C
741SNC
741WHC
70
70
80
70
70
3.5
3.5
2.5
3.5
3.5
70
55
2.0
70
70
80
50
50
70
70
90
110
50
60
70
50
50
3.5
3.5
2.5
2.5
2.5
3.5
3.5
2.5
4.0
3.0
3.0
5.5
0.4
0.4
50
38
1.5
27.1
@ 0.25 “ SP
50
38
1.5
27.1
@ 0.25 “ SP
80
2.5
744C
@ 0.25” SP
754RBC
754SNC
757SNC
DX50FL
DX50L
DX70FL
DX70L
DX90
DX110
EC50
EC60KIT
EC70
FQTR050C
FQTRE050C
HD50C
HD80C
** CONVERSIONS:
SONES
Powered Attic Ventilators
HD50C=DXH with FHD50C
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
CFM**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
34.4
32.3
Rev. 09/01/2012
Section 1-29
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
QTR070C
QTR070LC
QTR090C
QTR090LC
QTR110C
70
70
1.0
1.0
@ 0.10” SP
@ 0.25” SP
90
68
1.0
@ 0.10” SP
@ 0.25” SP
90
68
1.0
@ 0.10” SP
@ 0.25” SP
110
99
1.5
110
99
1.5
@ 0.25” SP
140
130
2.0
2.5
QTR110LC
QTR140C
SONES
6” duct
4” duct
WATTS
26.8
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SONES
WATTS
QTRE110C=HQTXR000C with FQTRE110C
@ 0.25” SP
110
90
1.3
36.3
QTRE110FLC
110
90
1.3
36.3
@ 0.25” SP
110
99
1.3
@ 0.25” SP
70.5
69.2
110
90
1.3
@ 0.25” SP
36.3
36.2
80
56
40
0.8
24.8
<0.3
12.9
29.7
26.4
QTRE110MG
70.5
69.2
QTRE110RF
70.5
69.2
QTRE2080WC
HS+
HS+
LS+
@ 0.25” SP
QTXE050C
50
31
<0.3
19.6
@ 0.25” SP
80
55
0.3
23.3
@ 0.25” SP
QTRE050RF
50
0.4
QTRE070C
0.8
28.4
@ 0.25 “ SP
70
48
26.4
70
48
0.8
28.4
@ 0.25” SP
90
68
0.6
QTRE070C=HQTXR000C with FQTRE070C
@ 0.25 “ SP
0.8
28.4
90
68
26.4
@ 0.25 “ SP
80
55
QTXE090C=HQTXE with FQTXE090C
@ 0.25” SP
0.6
QTRE075C
33.5
0.8
28.4
@ 0.25” SP
110
90
0.7
@ 0.25 “ SP
80
55
33.5
80
55
0.8
28.4
@ 0.25” SP
110
90
0.7
QTRE080C=HQTXR000C with FQTRE080C
@ 0.25 “ SP
51.3
80
56
40
0.8
24.8
@ 0.25” SP
150
118
1.4
QTRE080C2S
<0.3
12.9
50
49
50
50
<0.3
4.9
<0.3
5.1
90
90
90
89
<0.3
6.6
0.5
9.5
<0.3
6.5
<0.3
7.1
@ 0.25” SP
90
90
70
73
110
110
<0.3
7.7
@ 0.25” SP
110
110
<0.3
8.7
@ 0.25” SP
QTXE080C
QTXE090C
QTXE110C
QTRE080C
QTXE110H
QTXE150C
HS+
HS+
LS+
@ 0.25” SP
XB50C
6” Duct
@ 0.25” SP
QTRE080H
80
55
1.0
@ 0.25” SP
80
55
0.8
@ 0.25” SP
1.0
26.8
@ 0.25” SP
90
68
QTRE090C=HQTXR000C with FQTRE090C
@ 0.25” SP
90
68
1.0
26.8
QTRE080RF
28.4
28.1
28.4
4” Duct
@ 0.25” SP
XB90C
6” Rd. Duct
@ 0.25” SP
4” Duct
QTRE090C
@ 0.25” SP
XB90LC
QTRE090FLC
@ 0.25” SP
QTRE090MG
@ 0.25” SP
QTRE090RC
90
68
1.0
26.8
XB110C
1.0
29.7
26.4
90
68
1.0
29.7
26.4
100
81
1.5
36.3
@ 0.25 “ SP
110
90
1.3
36.3
@ 0.25” SP
QTRE110C
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
Pascals (Pa) = in. wg x 250
@ 0.25” SP
4” Duct
@ 0.25” SP
QTRE100H
** CONVERSIONS:
90
68
6” Rd. Duct
6” Rd. Duct
XB110LC 6” Rd. Duct
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-30
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
ZB90C
DETAILS
STATIC
*
PRESSURE**
CFM**
6” Rd. Duct
Airflow rate setting 90
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
4” Duct
Airflow rate setting 90
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25’ SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
6” Rd. Duct
Airflow rate setting 90
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
4” Duct
Airflow rate setting 70
6.6
<0.3
5.8
<0.3
5.1
<0.3
4.4
<0.3
4.0
<0.3
3.7
<0.3
3.4
Airflow rate setting 110
@ 0.25” SP
Airflow rate setting 100
@ 0.25” SP
Airflow rate setting 90
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
90
89
80
80
70
70
60
60
50
47
40
34
30
22
0.5
9.5
Airflow rate setting 30
@ 0.25” SP
0.3
7.6
<0.3
6.5
<0.3
5.5
<0.3
5.1
<0.3
4.3
<0.3
3.9
ZB110LC
Airflow rate setting 110
@ 0.25” SP
Airflow rate setting 100
@ 0.25” SP
Airflow rate setting 90
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
70
73
60
63
50
54
40
43
30
30
6.5
Airflow rate setting 50
@ 0.25” SP
<0.3
6.0
Airflow rate setting 40
@ 0.25” SP
<0.3
5.2
Airflow rate setting 30
@ 0.25” SP
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
<0.3
7.1
<0.3
6.4
<0.3
5.6
<0.3
4.9
502
503
504
505
508
509
<0.3
4.4
Kitchen Range Hoods – Ducted & Convertible
CFM**
SONES
WATTS
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
7.7
<0.3
7.0
<0.3
6.4
<0.3
5.8
<0.3
5.1
<0.3
4.6
<0.3
4.1
<0.3
3.7
<0.3
3.3
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
8.7
<0.3
7.3
<0.3
6.5
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
Downdraft Kitchen Exhausters
273003
273603
RMDD3004
RMDD3604
500
500
500
500
Kitchen - Exhaust Fans
@ 0.25’ SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25”SP
Airflow rate setting 30
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
<0.3
@ 0.25” SP
@ 0.25” SP
ZB90LC
90
90
80
79
70
71
60
61
50
49
40
36
30
23
DETAILS
STATIC
*
PRESSURE**
@ 0.25” SP
@ 0.25” SP
ZB90LC
WATTS
ZB110C
Airflow rate setting 80
ZB90C
SONES
MODEL
OR SERIES
Pascals (Pa) = in. wg x 250
153001
153004
153023
613004
619004
637004
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
APE130SS
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
@ 0.023” SP
@ 0.020” SP
270
160
350
180
270
180
8.0
5.0
6.5
6.5
6.0
6.5
300
300
300
450
450
900
4.5
4.5
4.5
9.0
9.0
9.5
440
200
440
200
7.0
0.7
7.0
0.9
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
160
70.1
162
70.2
Rev. 09/01/2012
Section 1-31
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
BC2130SS
Ver. HS+
Ver. WS+
290
130
9.0
1.5
E5036SS
Ver. HS+
Ver. LS+
BC4130SS
Ver. HS+
Ver. WS+
500
130
10.0
<0.3
E6030SS
BDF30SS
Ver. HS+
Ver. LS+
500
320
9.0
4.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6030SSC
BDF30WH
Ver. HS+
Ver. LS+
500
320
9.0
4.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.5
1.5
BDF302SS
Ver. HS+
Ver. LS+
500
320
9.0
4.5
E6036SS
BDF302WH
Ver. HS+
Ver. LS+
500
320
9.0
4.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
BP124ALN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
E6036SSC
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.5
1.5
BP124BLN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
E6036TSS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E6036TSSC
BP124WHN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E6042SS
BP130ALN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
BP130BLN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
E6042TSS
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
BP130SSN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
E6042TSSC
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E6048SS
BP130WWN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.5
1.5
E6048TSS
CM130WWN
Ver. HS+
Hor. HS+
160
160
6.5
6.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E1224SS
Ver. HS+
Ver. WS+
510
@ 0.003” SP 350
8.5
4.5
E6048TSSC
E1230SS
Ver. HS+
Ver. WS+
510
@ 0.003” SP 350
8.5
4.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1200
350
1200
350
14.5
2.0
14.0
2.0
E5030SS
Ver. HS+
Ver. LS+
510
340
9.0
5.0
E6430SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
BP124SSN
BP130WHN
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
510
340
9.0
5.0
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-32
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
E6430SSC
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.0
1.5
E66130SSAGLS Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
270
110
280
110
9.0
0.9
8.5
1.1
E6436SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
E66130WHAGLS Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
270
110
280
110
9.0
0.9
8.5
1.1
E6436SSC
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.0
1.5
EC621306SS
Ver. HS+
Ver. WS+
600
210
8.5
1.1
EC622301SS
Ver. HS+
Ver. WS+
1000
370
12.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
1100
300
1100
300
14.5
2.0
14.0
2.0
EC622309SS
Ver. HS+
Ver. WS+
900
470
14.5
4.5
ESB1030BL
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1100
300
1100
300
14.5
2.0
14.0
2.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.0
1.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
1100
300
1100
300
14.5
2.0
14.0
2.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1100
300
1100
300
14.5
2.0
14.0
2.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
GP124ALN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
600
150
600
150
13.0
1.5
13.0
1.5
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
GP124SSN
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
600
150
600
150
13.0
1.5
13.0
1.5
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
GP124WHN
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
1200
350
1200
350
14.5
2.0
14.0
2.0
GP124WWN
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
1100
300
1100
300
14.5
2.0
14.0
2.0
GP130SSN
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
GP130WHN
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
E6436TSS
E6436TSSC
ESB1030SS
E6442SS
ESB1030SSD
E6442SSC
ESB1030WH
E6442TSS
ESB1030WHD
E6442TSSC
E6448SS
E6448SSC
E6448TSS
E6448TSSC
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
36.2
Rev. 09/01/2012
Section 1-33
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
GP130WWN
Ver. HS+
Hor. HS+
7”Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
P5
Ver. HS+
Hor. HS+
460
500
10.5
10.0
P8
Ver. HS+
Hor. HS+
850
900
10.5
10.0
QP130BLC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP130SSC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QP130WWC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7”Rd. Ver. HS+
7”Rd. Ver. LS+
290
120
300
120
250
120
5.0
0.8
5.0
0.8
5.0
0.8
QS130AAN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS130BLN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS130SSN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
QS130WWN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230BLN
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QS230SSN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS230WWN
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
QS330BLN
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS330SSN
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS330WWN
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS3336SSN
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
QS3336WWN
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-34
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
QSE130BL
QSE130SS
QSE130WW
DETAILS
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
Hor. HS+
Hor. WS+
Ver. HS+
Ver. WS+
7” Rd. HS+
7” Rd. WS+
STATIC
*
PRESSURE**
CFM**
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
@ 0.027” SP
@ 0.046” SP
@ 0.042” SP
SONES
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
210
110
210
130
220
140
5.0
1.5
5.5
2.0
5.5
2.0
89.7
38.6
89.3
38.0
88.4
37.9
QT230AAN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
QT230BCN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
QT230BLN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
QT230WWN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
QT236BLN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
QT236SSN
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
RM503004
RM503604
RM523004
RM523604
RM533004
RM533604
RM659004
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver. HS+
Ver HS+
270
270
370
370
370
370
450
6.5
6.5
7.0
7.0
7.0
7.0
9.0
ROB1530BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.8
QT230SSN
QT236WWN
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
ROB1530SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.8
ROB1530WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.8
ROB1530WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.8
ROB3530BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROB3530BLD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROB3530SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROB3530SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROB3530WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROB3530WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
380
180
90
6.5
4.5
3.5
Other Rooms – Exhaust Fans (all models)
510
511
512
Remote Exterior Mounted Ventilators
331H
@ 0.03” SP
@ 0.10” SP
640
600
332H
@ 0.03” SP
@ 0.10” SP
940
900
335
@ 0.03” SP
@ 0.10” SP
1230
1200
336
@ 0.03” SP
@ 0.10” SP
1530
1500
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-35
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
BROAN –NUTONE LLC
MODEL
OR SERIES
277
110
237.0
237.0
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
252
103
229.0
229.0
6.0
5.0
5.5
31098
Hor. HS+
Ver. HS+
7” Rd. HS+
180
210
210
6.0
5.0
5.5
31099
Hor. HS+
Ver. HS+
7” Rd. HS+
180
210
210
6.0
5.0
5.5
31100
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31102
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31104
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31105
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31106
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31112
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31114
Hor. BS+
Hor. HS+
Ver. BS+
Ver. HS+
7” Rd. BS+
7” Rd. HS+
430
300
380
280
350
270
8.0
4.5
8.5
5.5
8.0
5.5
31193
Hor. HS+
Ver. HS+
7” Rd. HS+
180
210
210
6.0
5.0
5.5
GuardianPlus Air Systems
Integrated Supply & Exhaust Ventilators
GSHH3K
GSVH1K
Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
270
122
227.0
227.0
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
254
113
224.0
224.0
Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
277
110
237.0
237.0
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
252
103
229.0
229.0
Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
279
110
231.0
231.0
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
257
104
224.0
224.0
BROAN –NUTONE LLC
Kenmore (Canada)
Kitchen Range Hoods – Ducted & Convertible
31001
Hor. HS+
Ver. HS+
7” Rd. HS+
180
210
210
6.0
5.0
5.5
31020
Hor. HS+
Ver. HS+
7” Rd. HS+
180
180
210
7.0
7.5
7.0
31022
Hor. HS+
Ver. HS+
7” Rd. HS+
180
180
210
7.0
7.5
7.0
31090
Hor. HS+
Ver. HS+
7” Rd. HS+
180
210
210
6.0
5.0
5.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
180
210
210
BROAN –NUTONE LLC
GSEH3K
SONES
Hor. HS+
Ver. HS+
7” Rd. HS+
Integrated Supply & Exhaust Ventilators
Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
CFM**
31093
Broan-NuTone
HF 3.1
DETAILS
STATIC
*
PRESSURE**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-36
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
31600
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
605RP
665RP
668RP
31602
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
671R
31604
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
31605
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
31608
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
DETAILS
STATIC
*
PRESSURE**
Hor. HS+
Ver. HS+
7” Rd. HS+
300
280
280
4.5
5.5
5.0
Hor. HS+
Ver. HS+
7” Rd. HS+
300
280
280
4.5
5.5
5.0
31614
Hor. HS+
Ver. HS+
7” Rd. HS+
300
280
280
4.5
5.5
5.0
31615
Hor. HS+
Ver. HS+
7” Rd. HS+
300
280
280
4.5
5.5
5.0
31624
31812
31820
Hor. HS+
Ver. HS+
7” Rd. HS+
220
210
230
5.0
5.5
5.0
Hor. HS+
Ver. HS+
7” Rd. HS+
Hor. HS+
Ver. HS+
7” Rd. HS+
190
190
220
190
190
220
8.0
7.0
7.0
8.0
7.0
7.0
90
78
3.0
110
60
70
50
70
70
70
4.0
3.0
6.0
4.0
3.5
3.5
2.0
70
55
1.5
@ 0.25” SP
34.4
32.3
70
55
1.5
@ 0.25” SP
34.4
32.3
70
2.0
70
55
1.5
70
70
3.5
3.5
80
67
2.5
100
3.5
50
40
2.5
@ 0.25” SP
42.1
41.0
100
85
2.0
@ 0.25” SP
70.2
66.0
100
85
2.0
@ 0.25” SP
70.2
66.0
80
67
2.5
@ 0.25” SP
29.0
27.8
70
63
3.0
@ 0.25” SP
57.3
56.4
70
63
3.0
@ 0.25” SP
57.3
56.4
80
68
2.0
24.9
@ 0.25” SP
80
68
2.0
24.9
@ 0.25” SP
80
68
2.0
24.9
@ 0.25” SP
100
88
1.5
36.4
@ 0.25” SP
100
88
1.5
36.4
@ 0.25” SP
@ 0.25” SP
672R
690NT
695
696N
741SNNT
741WHNT
742RBNT
744NT
745BNNT
Hor. HS+
Ver. HS+
7” Rd. HS+
190
190
220
8.0
7.0
7.0
@ 0.25” SP
754RBNT
754SNNT
757SNNT
@ 0.25” SP
761WHNT
763RLN
765HL
765HFL
768CHNT
769RFT
31822
769RL
772RBNT
BROAN – NUTONE LLC
773BNNT
NuTone
778WHNT
Bathroom – Exhaust Fans (all models)
50NT
50
35
1.5
@ 0.25” SP
80
65
2.0
@ 0.25” SP
80NT
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
17.8
26.1
WATTS
4.0
4.0
4.0
744SFLNT
31612
SONES
70
70
70
744FLNT
31610
CFM**
781WHNT
788CHNT
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
72.8
70.3
34.4
32.3
29.0
27.8
Rev. 09/01/2012
Section 1-37
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
8663RP
8664RP
8814R
SONES
100
100
110
8832SA
@ 0.25” SP
8832WH
@ 0.25” SP
9093WH
9417DN
9427P
9905
9965
HD50LNT
@ 0.25” SP
HD50NT
80
69
3.5
3.5
4.0
2.5
80
69
2.5
70
70
70
70
70
3.5
3.5
3.5
4.0
4.0
50
38
1.5
50
38
1.5
@ 0.25” SP
50
38
1.5
@ 0.25” SP
HD50NT=RDA with HD50RDB
WATTS
MODEL
OR SERIES
DETAILS
QTNLEDB
60.8
59.0
60.8
59.0
4” duct
4” duct
6” duct
6” duct
STATIC
*
PRESSURE**
80
65
2.5
@ 0.25” SP
80
67
2.5
@ 0.25” SP
HD80NT
LPN80
4” Duct
@ 0.25” SP
3” Duct
@ 0.25”SP
80
60
70
55
80
55
0.8
28.4
@ 0.25” SP
QTREN080 =QTXRN000HF with QTREN080F
@ 0.25” SP
80
55
0.8
28.4
QTREN080FLT
80
55
0.8
28.4
80
55
0.8
28.4
110
90
1.3
36.3
@ 0.25” SP
QTREN110=QTXRN000HF with QTREN110F
@ 0.25” SP
110
90
1.3
36.3
QTREN110FLT
110
90
1.3
36.3
110
90
1.3
36.3
50
28
0.4
@ 0.25” SP
26.8
26.6
80
66
1.0
@ 0.25” SP
56.6
57.8
80
66
1.0
@ 0.25” SP
56.6
57.8
110
98
1.5
@ 0.25” SP
70.5
69.2
110
98
1.5
@ 0.25” SP
70.5
69.2
50
31
<0.3
19.6
@ 0.25” SP
80
55
0.3
23.3
@ 0.25” SP
80
55
0.3
23.3
@ 0.25” SP
110
90
0.7
33.5
@ 0.25” SP
110
90
0.7
33.5
@ 0.25” SP
110
90
0.7
33.5
@ 0.25” SP
110
90
0.7
@ 0.25” SP
33.5
33.0
150
118
1.4
51.3
@ 0.25” SP
QTREN080
QTREN080FLT=QTXRN000HL with QTREN080FLFT
@ 0.25” SP
QTREN110
49.0
48.0
29.0
27.8
25.6
1.3
25.7
QTREN110FLT=QTXRN000HL with QTREN110FLFT
@ 0.25” SP
QTRN050F
QTRN080
3.0
80
55
0.8
@ 0.25” SP
80
66
0.8
@ 0.25” SP
110
90
1.0
@ 0.25” SP
110
90
1.0
@ 0.25” SP
130
116
130
114
2.0
QTN80E
QTN80L
QTN110E
QTN110LE
QTN130E
QTN130LE
4” Duct
4” Duct
6” Duct
6” Duct
4” Duct
4” Duct
6” Duct
6” Duct
@ 0.25”SP
@ 0.25” SP
@ 0.25”SP
@ 0.25” SP
130
116
130
114
1.5
28.4
QTRN110
59.3
60.8
QTRN110L
36.3
QTXEN050
36.3
48.3
QTXEN080
QTXEN080FLT
4” duct
4” duct
6” duct
6” duct
@ 0.25” SP
@ 0.25” SP
90
72
110
90
QTXEN110
2.0
48.3
1.5
49.0
0.9
34.5
0.7
34.9
QTXEN110FLT
QTXEN110SFLT
QTXEN150
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
0.7
34.9
49.0
QTXEN110S
QTNLEDA
34.5
27.1
1.1
110
0.9
27.1
QTRN080L
QT9093WH
WATTS
@ 0.25” SP
@ 0.25” SP
HD80LNT
SONES
90
72
110
90
@ 0.25” SP
@ 0.25” SP
27.0
25.1
CFM**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-38
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
QTXEN150FLT
@ 0.25” SP
SONES
150
118
1.4
WATTS
51.3
50.1
MODEL
OR SERIES
ZN80L
DETAILS
STATIC
*
PRESSURE**
6” Rd. Duct
Airflow rate setting 80
@ 0.25” SP
QTXN110HL
110
84
0.9
@ 0.25” SP
0.9
@ 0.25” SP
110
84
42.8
41.7
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
QTXN110HFLT
42.8
41.7
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
QTXN110SL
@ 0.25” SP
110
90
0.9
33.5
33.0
50
49
50
50
<0.3
4.9
<0.3
5.1
50
48
50
50
<0.3
4.9
<0.3
5.3
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
XN50
6” Rd. Duct
@ 0.25 “ SP
4” Duct
@ 0.25” SP
@ 0.25” SP
ZN80L
4” Duct
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
XN50L
6” Rd. Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
XN80
6” Rd. Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
80
79
80
80
<0.3
5.8
0.3
7.6
ZN110
Airflow rate setting 110
@ 0.25” SP
Airflow rate setting 100
@ 0.25” SP
XN80L
6” Rd. Duct
@ 0.25” SP
80
80
60
63
@ 0.25” SP
110
110
@ 0.25” SP
4” Duct
<0.3
6.0
Airflow rate setting 90
@ 0.25” SP
<0.3
6.4
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
XN110
6” Rd. Duct
<0.3
7.7
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
XN110L
6” Rd. Duct
@ 0.25” SP
110
110
<0.3
8.7
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
ZN80
6” Rd. Duct
Airflow rate setting 80
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
ZN80
4” Duct
Airflow rate setting 80
<0.3
5.8
Airflow rate setting 30
@ 0.25” SP
<0.3
5.1
<0.3
4.4
<0.3
4.0
<0.3
3.7
<0.3
3.4
ZN110L
Airflow rate setting 110
@ 0.25” SP
Airflow rate setting 100
@ 0.25” SP
Airflow rate setting 90
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
80
79
70
71
60
61
50
49
40
36
30
23
Pascals (Pa) = in. wg x 250
80
80
70
70
60
60
50
47
40
34
30
22
0.3
7.6
Airflow rate setting 60
@ 0.25” SP
<0.3
6.5
Airflow rate setting 50
@ 0.25” SP
<0.3
5.5
Airflow rate setting 40
@ 0.25” SP
<0.3
5.1
Airflow rate setting 30
@ 0.25” SP
<0.3
4.3
<0.3
3.9
CFM**
SONES
80
80
70
70
60
60
50
50
40
40
30
30
WATTS
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
60
63
50
54
40
43
30
30
<0.3
6.4
<0.3
5.6
<0.3
4.9
<0.3
4.4
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
7.7
<0.3
7.0
<0.3
6.4
<0.3
5.8
<0.3
5.1
<0.3
4.6
<0.3
4.1
<0.3
3.7
<0.3
3.3
<0.3
8.7
<0.3
7.3
<0.3
6.5
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-39
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
Inline Fans (all models)
ILF120
ILF130
ILF250
ILF360
ILF530
ILRF
110
120
250
360
530
140
MODEL
OR SERIES
DETAILS
210
160
NS130BL
SONES
WATTS
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7” Rd. Ver. HS+
7” Rd. Ver. WS+ @ 0.039” SP
190
130
190
100
230
150
6.0
2.0
6.0
2.0
6.0
2.0
NS6530BL
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7”Rd. Ver. HS+
7”Rd. Ver. WS+ @ 0.039” SP
190
130
190
100
230
150
6.0
2.0
6.0
2.0
6.0
2.0
NS6530SS
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7”Rd. Ver. HS+
7”Rd. Ver. WS+ @ 0.039” SP
190
130
190
100
230
150
6.0
2.0
6.0
2.0
6.0
2.0
18.0
71.0
118
6.5
5.0
Kitchen Range Hoods – Ducted & Convertible
CFM**
NS6530BC
Kitchen - Exhaust Fans
8210
8310
STATIC
*
PRESSURE**
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
NS6530WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
Ver. HS+
Ver. WS+
@ 0.038” SP
Hor. HS+
Hor. WS+
@ 0.031” SP
7”Rd. Ver. HS+
7”Rd. Ver. WS+ @ 0.039” SP
190
130
190
100
230
150
6.0
2.0
6.0
2.0
6.0
2.0
NSP130SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
440
120
440
130
7.0
0.5
7.0
0.5
NSPM250
NSPM390
Ver. HS+
Ver. HS+
250
390
8.0
6.0
NTM30SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
Ver. HS+
Ver. LS+
Ver. HS+
Ver. LS+
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
330
110
350
100
290
100
7.5
0.5
8.0
0.9
8.0
0.5
NS5430SS
Ver. HS+
Ver. LS+
350
190
8.5
2.5
NS5830SS
Ver. HS+
Ver. LS+
350
190
8.5
2.5
NS130SS
NS130WW
NS136BL
NS136SS
NS136WW
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
NTM30WW
500
320
500
320
9.0
4.5
9.0
4.5
WS130AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS130BC
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS130BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-40
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
WS130SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS142SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS130SSMX
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
200
220
200
5.5
5.0
5.5
WS142WW
WS130WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS230WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd.Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
WS236WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd.Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
WS242WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd.Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
WS330BL
WS136SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd.Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
WS330SS
WS136WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS142AA
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd.Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
WS330WW
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd.Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
WS136AA
WS136BC
WS136BL
WS142BL
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-41
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
WS336SS
WS342SS
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd.Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd.Ver. BS+
7” Rd. Ver. HS+
7” Rd. Ver. LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
7” Rd. HS+
7” Rd. WS+
210
110
220
100
210
110
5.5
1.2
5.0
1.0
5.5
1.3
WATTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
744NTC
@ 0.021” SP
@0.017” SP
12.0
80
80
70
110
80
80
100
100
70
70
80
100
2.5
2.5
3.0
4.0
2.5
2.5
3.5
3.5
3.5
3.5
2.5
4.0
70
48
0.8
28.4
@ 0.25” SP
80
55
0.8
28.4
@ 0.25” SP
80
56
40
0.8
24.8
<0.3
12.9
757SNNTC
765BNNTC
769RL
8814R
8832SA
8832WH
8663RP
8664RP
9417DN
9425WHC
NT080C
NT100C
QTREN070C
@ 0.033” ST
QTREN080C2S
HS+
HS+
LS+
@ 0.25” SP
QTREN080H
Other Rooms – Exhaust Fans (all models)
QT-200
QT-300
Ver.
Hor.
200
200
2.0
2.0
QTREN090C
Ver.
Hor.
300
300
4.5
4.5
QTREN090FLC
Remote Exterior Mounted Ventilators
600
640
@ 0.03” SP
332H
80
55
1.0
28.4
28.1
90
68
1.0
26.8
@ 0.25” SP
90
68
1.0
26.8
@ 0.25” SP
100
81
1.5
36.3
@ 0.25” SP
110
90
1.3
36.3
@ 0.25” SP
110
90
1.3
36.3
@ 0.25” SP
335
@ 0.03” SP
336
80
56
40
0.8
24.8
@ 0.03” SP
<0.3
12.9
QTREN110C
900
940
@ 0.03” SP
QTREN110FLC
1200
1230
1500
1530
QTREN2080WC
HS+
HS+
LS+
@ 0.25” SP
QTRN090C
BROAN - NUTONE LLC
90
68
1.0
@ 0.25” SP
29.7
26.4
90
68
1.0
@ 0.25” SP
29.7
26.4
110
99
1.5
@ 0.25” SP
70.5
69.2
110
99
1.5
@ 0.25” SP
70.5
69.2
50
31
<0.3
19.6
@ 0.25” SP
80
55
90
68
0.3
23.3
0.6
26.4
QTRN090LC
NuTone (Canada)
34.4
32.3
@ 0.25” SP
QTREN100H
331H
WATTS
70
55
@ 0.25” SP
QTREN080C
WS1530SS
SONES
QTRN110C
Bathroom – Exhaust Fans (all models)
QTRN110LC
671SP
672SP
690UPGKIT
695C
696NC
741SNNTC
741WHNTC
742RBNTC
90
110
60
70
50
70
70
70
2.5
4.0
3.0
5.5
3.0
3.5
3.5
2.0
QTXEN050C
QTXEN080C
@ 0.25” SP
QTXEN090C
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-42
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
QTXEN110C
@ 0.25” SP
SONES
110
90
0.7
WATTS
33.5
MODEL
OR SERIES
ZN90LC
DETAILS
STATIC
*
PRESSURE**
6” Rd. Duct
Airflow rate setting 90
@ 0.25” SP
QTXEN110H
110
90
0.7
@ 0.25” SP
1.4
@ 0.25” SP
150
118
33.5
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
QTXEN150C
51.3
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
XN50C
6” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
50
49
50
50
<0.3
4.9
Airflow rate setting 50
@ 0.25” SP
<0.3
5.1
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
XN90C
6” Rd. Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
90
90
90
89
<0.3
6.6
0.5
9.5
@ 0.25” SP
ZN90LC
4” Duct
Airflow rate setting 70
@ 0.25’ SP
XN90LC
6” Rd. Duct
@ 0.25” SP
90
90
70
73
@ 0.25” SP
110
110
@ 0.25” SP
4” Duct
<0.3
6.5
Airflow rate setting 60
@ 0.25” SP
<0.3
7.1
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
XN110C
6” Rd. Duct
<0.3
7.7
@ 0.25”SP
Airflow rate setting 30
@ 0.25” SP
XN110LC 6” Rd. Duct
@ 0.25” SP
110
110
<0.3
6” Rd. Duct
Airflow rate setting 90
ZN110C
Airflow rate setting 110
Airflow rate setting 100
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
90
90
80
79
70
71
60
61
50
49
40
36
30
23
<0.3
6.6
<0.3
5.8
<0.3
5.1
<0.3
4.4
<0.3
4.0
<0.3
3.7
<0.3
3.4
@ 0.25” SP
Airflow rate setting 90
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25” SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
ZN90C
4” Duct
Airflow rate setting 90
@ 0.25” SP
Airflow rate setting 80
@ 0.25” SP
Airflow rate setting 70
@ 0.25’ SP
Airflow rate setting 60
@ 0.25” SP
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
90
89
80
80
70
70
60
60
50
47
40
34
30
22
0.5
9.5
ZN110LC Airflow rate setting 110
@ 0.25” SP
0.3
7.6
Airflow rate setting 100
@ 0.25” SP
<0.3
6.5
Airflow rate setting 90
@ 0.25” SP
<0.3
5.5
Airflow rate setting 80
@ 0.25” SP
<0.3
5.1
Airflow rate setting 70
@ 0.25” SP
<0.3
4.3
Airflow rate setting 60
@ 0.25” SP
<0.3
3.9
Airflow rate setting 50
@ 0.25” SP
Airflow rate setting 40
@ 0.25” SP
Airflow rate setting 30
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
SONES
WATTS
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
6.5
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
70
73
60
63
50
54
40
43
30
30
<0.3
7.1
<0.3
6.4
<0.3
5.6
<0.3
4.9
<0.3
4.4
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
7.7
<0.3
7.0
<0.3
6.4
<0.3
5.8
<0.3
5.1
<0.3
4.6
<0.3
4.1
<0.3
3.7
<0.3
3.3
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
<0.3
8.7
<0.3
7.3
<0.3
6.5
<0.3
6.0
<0.3
5.2
<0.3
4.6
<0.3
4.1
<0.3
3.6
<0.3
3.3
8.7
@ 0.25” SP
ZN90C
CFM**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-43
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
Inline Fans (all models)
ILF120
ILF130
ILF250
ILF360
ILF530
ILRF
110
120
230
360
530
140
18.0
71.0
118
MODEL
OR SERIES
DETAILS
CFM**
SONES
WATTS
RL6130FSS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
RL6130FWH
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
RL6130FWW
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
RL6130WWC
Ver. HS+
Hor. HS+
160
160
6.5
6.5
SM6530AL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
SM6530BL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
SM6530SS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
SM6530WH
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
Kitchen Range Hoods – Ducted & Convertible
HDN1730SS
STATIC
*
PRESSURE**
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
HDN6430BL
Hor. HS+
Ver. HS+
7” Rd. HS+
180
180
210
7.0
7.5
7.0
SM6530WW
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
190
190
220
7.0
8.0
7.0
HDN6430SS
Hor. HS+
Ver. HS+
7” Rd. HS+
180
180
210
7.0
7.5
7.0
WA6530AA
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
HDN6430WW
Hor. HS+
Ver. HS+
7” Rd. HS+
180
180
210
7.0
7.5
7.0
WA6530BL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
NTM30SS
Ver. HS+
Ver. LS+
500
320
9.0
4.5
WA6530SS
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
NTM30WH
Ver. HS+
Ver. LS+
500
320
9.0
4.5
WA6530WW
NTM302SS
Ver. HS+
Ver. LS+
500
320
9.0
4.5
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
210
180
210
5.0
6.0
5.5
WS130AAC
NTM302WH
Ver. HS+
Ver. LS+
500
320
9.0
4.5
RL6124FAL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
WS130BLC
RL6124FWW
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
RL6130FAL
Ver. HS+
Hor. HS+
7” Rd. Ver. HS+
180
180
210
7.5
7.0
7.0
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
HDN1730SSD
HDN1730WH
HDN1730WHD
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-44
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
WS130SSC
WS130WWC
WS230BLC
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
210
110
220
110
230
120
5.5
1.5
5.0
1.5
5.0
1.5
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
7" Rd. Ver. HS+
7” Rd. Ver. LS+
280
110
300
100
280
110
5.5
1.0
4.5
0.9
5.0
0.8
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver HS+
7” Rd. Ver LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver HS+
7” Rd. Ver LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
Ver. BS+
Ver. HS+
Ver. LS+
Hor. BS+
Hor. HS+
Hor. LS+
7” Rd. Ver. BS+
7” Rd. Ver HS+
7” Rd. Ver LS+
380
280
110
430
300
100
350
270
100
8.5
5.5
0.3
8.0
4.5
0.4
8.0
5.5
0.5
WATTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
WS230WWC
WS330BLC
WS330SSC
WS330WWC
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
SONES
WATTS
Other Rooms – Exhaust Fans (all models)
QT-200
Ver.
Hor.
200
200
2.0
2.0
QT-300
Ver.
Hor.
300
300
4.5
4.5
Remote Exterior Mounted Ventilators
331H
@ 0.03” SP
600
640
@ 0.03” SP
900
940
@ 0.03” SP
1200
1230
@ 0.03” SP
1500
1530
332H
335
336
WS230SSC
CFM**
CONTINENTAL FAN MANUFACTURING, INC
CFM
Bathroom – Exhaust Fans (all models)
TBF90
HS+
LS+
TBF120
HS+
@ 0.25” SP
LS+
@ 0.25” SP
80
50
2.0
0.9
26.1
21.1
110
95
70
56
2.0
39.5
1.0
34.8
TBFR90L
HS+
LS+
80
50
2.0
0.4
23.9
20.6
TBFR120L
HS+
LS+
100
70
2.0
0.8
34.7
32.3
TBFS90L
HS+
HS+ @ 0.25” SP
LS+
LS+ @ 0.25” SP
70
60
50
40
2.0
24.9
1.0
20.1
HS+
LS+
90
70
2.0
1.0
32.6
31.1
TBFS120L
Inline Fans (all models)
AXC100A
AXC100AES
AXC100B
AXC125AES
AXC125B
AXC150A
AXC150AES
AXC150BES
AXC 200A
AXC200AES
AXC200BES
90
130
140
150
160
200
190
260
350
300
520
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
43.3
83.4
44.4
85.4
46.8
89.2
84.5
188
Rev. 09/01/2012
Section 1-45
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
AXC250ES
AXC300AES
AXC300BES
SONES
550
700
910
WATTS
197
206
312
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
VFB25AX
HS+
HS+
LS+
LS+
CFM**
@ 0.25” SP
@ 0.25” SP
VHB37AC
SONES
110
89
80
53
WATTS
1.0
0.5
16.0
18.1
7.7
8.7
80
3.0
12.3
DELTA ELECTRONICS INC..
Delta
ELICA S.p.A
Elica
Bathroom – Exhaust Fans (all models)
VFB050B3A1
@ 0.25” SP
50
36
1.0
1.2
6.4
6.3
@ 0.25” SP
50
36
<0.3
1.0
4.0
5.2
@ 025” SP
50
38
<0.3
0.7
4.3
5.8
70
54
2.0
1.5
13.2
11.6
@ 0.25” SP
70
54
50
36
2.0
1.5
1.0
1.2
13.2
11.6
6.5
6.4
@ 0.25” SP
80
66
0.8
1.1
7.9
9.3
@ 0.25” SP
80
66
0.8
1.0
8.7
9.7
@ 0.25” SP
80
58
0.5
1.0
9.0
11.3
ELICA S.p.A
80
56
<0.3
0.6
7.2
9.3
Whirlpool
@ 0.25” SP
@ 0.25” SP
80
56
<0.3
0.6
7.2
9.3
@ 0.25” SP
80
49
0.6
1.0
9.6
10.0
@ 0.25” SP
80
58
0.5
1.0
9.0
11.3
@ 0.25” SP
110
81
1.0
1.5
14.2
15.0
@ 0.25” SP
110
81
1.0
1.5
14.2
15.0
@ 0.25” SP
110
89
1.1
1.4
15.4
17.2
130
107
1.3
@ 0.25” SP
19.1
18.8
VFB050C4A1
VFB050C4L1
VFB070B3A1
@ 0.25” SP
VFB070B3X1 HS+
HS+
LS+
LS+
@ 0.25” SP
VFB080C4A1
VFB080C4L1
VFB080D4LED1
VFB25AC
VFB25ACH
VFB25ACL
VFB25ACLED
VFB25AD
VFB25ADH
VFB25ADL
VFB25AEH
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Kitchen Range Hoods – Ducted & Convertible
EBL230ES
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
270
150
290
150
7.0
0.3
7.0
<0.3
133
18.1
134
18.1
EBL236ES
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
270
150
290
150
7.0
0.3
7.0
<0.3
133
18.1
134
18.1
EMZ230ES
Ver. HS+
Ver. MS+
290
200
5.0
3.0
170
70
Ver. WS+
Ver. HS+
Ver. MS+
Ver. WS+
120
290
200
120
1.0
5.0
3.0
1.0
35
170
70
35
EMZ236ES
Kitchen Range Hoods – Ducted & Convertible
GXU7130DXB
Ver. HS+
Ver. MS+
Ver. WS+
Hor. HS+
Hor. MS+
Hor. WS+
270
170
150
290
170
150
7.0
2.0
0.3
7.0
1.5
<0.3
133
38.8
18.1
134
38.7
18.1
GXU7130DXQ
Ver. HS+
Ver. MS+
Ver. WS+ @ 0.013” SP
Hor. HS+
Hor. MS+
Hor. WS+ @ 0.011” SP
270
170
150
290
170
150
7.0
2.0
0.3
7.0
1.5
<0.3
133
38.8
18.1
134
38.7
18.1
GXU7130DXS
Ver. HS+
Ver. MS+
Ver. WS+ @ 0.013” SP
Hor. HS+
Hor. MS+
Hor. WS+ @ 0.011” SP
270
170
150
290
170
150
7.0
2.0
0.3
7.0
1.5
<0.3
133
38.8
18.1
134
38.7
18.1
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-46
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SONES
WATTS
GXW7330DXS
Ver. HS+
Ver. MS+
Ver. WS+ @ 0.010” SP
310
210
150
6.0
3.5
1.2
169
69.6
32.5
GXW7336DXS
Ver. HS+
Ver. MS+
Ver. WS+ @ 0.010” SP
310
210
150
6.0
3.5
1.2
169
69.6
32.5
GE APPLIANCES
MODEL
OR SERIES
DETAILS
CFM**
SONES
WATTS
JV248P
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
180
180
200
6.0
7.0
6.0
JV338HBB
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
160
160
170
6.0
7.0
6.0
JV338HCC
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
160
160
170
6.0
7.0
6.0
JV338HWW
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
160
160
170
6.0
7.0
6.0
JV347H
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
180
180
200
6.0
7.0
6.0
JV348L
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
180
180
200
6.0
7.0
6.0
JV367H
7” Rd. Ver. HS+
3-1/4 x 10 Ver. HS+
3 1/4 x 10 Hor. HS+
200
180
180
6.0
6.0
7.0
GE Appliances
Downdraft Kitchen Exhausters
STATIC
*
PRESSURE**
JP389BJBB
3-1/4 x 10 Ver. HS+
330
7.5
JP389WJWW
3-1/4 x 10 Ver. HS+
330
7.5
JVB37HBB
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
JVB67HBB
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
JVB94SHSS
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
JV394SBB
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
320
110
4.5
<0.3
JVB98SHSS
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
JV535HBB
PGP989DNBB
3-1/4 x 10 Ver. HS+
330
7.5
PGP989SNSS
3-1/4 x 10 Ver. HS+
330
7.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
PGP989TNWW
3-1/4 x 10 Ver. HS+
330
7.5
JV535HCC
PGP990DENBB 3-1/4 x 10 Ver. HS+
390
6.5
PGP990DENWW 3-1/4 x 10 Ver. HS+
390
6.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
PGP990SENSS 3-1/4 x 10 Ver. HS+
390
6.5
JV535HWW
PP989DNBB
3-1/4 x 10 Ver. HS+
330
7.5
PP989SNSS
3-1/4 x 10 Ver. HS+
330
7.5
PP989TNWW
3-1/4 x 10 Ver. HS+
330
7.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
JV536HSS
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
JV565HBB
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
Kitchen Range Hoods – Ducted & Convertible
CV936MSS
7” Rd. Ver HS+
7” Rd. Ver. WS
590
160
7.5
0.4
CV966TSS
7” Rd. Ver HS+
7” Rd. Ver. WS+
590
160
7.5
0.4
JV247P
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Hor. HS+
7” Rd. Ver. HS+
180
180
200
6.0
7.0
6.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-47
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
JV565HCC
JV565HWW
JV566HSS
JV635HBB
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3-1/4 x 10 Hor. WS+
240
160
220
140
220
150
4.5
2.0
4.5
1.5
4.5
1.5
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
7” Rd. Ver. HS+
7” Rd. Ver. WS+
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
3 1/4 x 10 Hor. HS+
3 1/4 x 10 Hor. WS+
390
160
350
150
380
150
7.0
0.8
8.5
1.0
7.5
1.0
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
320
110
4.5
<0.3
WATTS
MODEL
OR SERIES
DETAILS
JV636HSS
JV665HBB
JV665HWW
JV666HSS
JV694SBB
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
CFM**
SONES
WATTS
JV930SCBR
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
320
110
4.5
<0.3
JV936DSS
7” Rd. Ver HS+
7” Rd. Ver. WS+
590
160
7.5
0.4
JV960SCBR
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
320
110
4.5
<0.3
JV966DSS
7” Rd. Ver HS+
7” Rd. Ver. WS+
590
160
7.5
0.4
JVE40DTBB
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
3-1/4” X 10” Hor. HS+
3-1/4” X 10” Hor. WS+
210
110
240
120
6.0
1.3
5.5
1.2
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
3-1/4” X 10” Hor. HS+
3-1/4” X 10” Hor. WS+
210
110
240
120
6.0
1.3
5.5
1.2
3-1/4” X 10” Ver. HS+
3-1/4” X 10” Ver. WS+
3-1/4” X 10” Hor. HS+
3-1/4” X 10” Hor. WS+
210
110
240
120
6.0
1.3
5.5
1.2
8” Rd. Ver. HS+
8” Rd. Ver. WS+
8” Rd. Ver. HS+
8” Rd. Ver. WS+
450
210
450
210
7.0
1.5
7.0
1.5
8” Rd. Ver. HS+
8” Rd. Ver. WS+
450
210
7.0
1.5
JVE40DTWW
JVE40STSS
PV970NSS
JV635HWW
STATIC
*
PRESSURE**
PV976NSS
PV977NSS
GE APPLIANCES
Monogram
Downdraft Kitchen Exhausters
ZVB30BHBB
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
ZVB36BHBB
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
ZVB30SHSS
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
ZVB36SHSS
3-1/4 x 10 Ver. HS+
3-1/4 x 10 Ver. WS+
390
170
10.5
2.5
Kitchen Range Hoods – Ducted & Convertible
ZV30HSRSS
8” Rd. Ver. HS+
8” Rd. Ver. WS+
530
240
9.0
2.0
ZV30RSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
32.2
32.4
32.2
32.4
32.2
32.4
Rev. 09/01/2012
Section 1-48
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SONES
WATTS
ZV30SSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
ZVC36LSS
8” Rd. Ver. BS+
8” Rd. Ver. WS+
640
250
14.0
3.5
ZV30TSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
ZVC42LSS
8” Rd. Ver. BS+
8” Rd. Ver. WS+
1140
490
16.5
4.0
ZV36RSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
ZVC48LSS
8” Rd. Ver. BS+
8” Rd. Ver. WS+
1140
490
16.5
4.0
ZV36SSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
ZV36TSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
620
240
9.0
1.1
ZV42ISHSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
1090
430
13.0
2.5
ZV48RSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
1090
430
13.0
2.5
ZV48SSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
1090
430
13.0
2.5
ZV48TSFSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
1090
430
13.0
2.5
ZV54ISHSS
10” Rd. Ver. HS+
10” Rd. Ver. WS+
1090
430
13.0
2.5
ZV750SPSS
6” Rd. Ver. HS+
6” Rd. Ver. WS+
350
170
6.0
1.1
ZV755SPSS
6” Rd. Ver. BS+
6” Rd. Ver. WS+
490
210
10.0
2.0
ZV800BJBB
6” Rd. Ver. HS+
6” Rd. Ver. WS+
460
220
7.0
2.0
ZV800SJSS
6” Rd. Ver. HS+
6” Rd. Ver. WS+
460
220
7.0
2.0
ZV830SMSS
8” Rd. Ver. HS+
8” Rd. Ver. WS+
420
190
9.0
2.0
ZV850SPSS
6” Rd. Ver. HS+
6” Rd. Ver. WS+
350
170
6.0
1.1
ZV855SPSS
6” Rd. Ver. BS+
6” Rd. Ver. WS+
490
210
10.0
2.0
ZV900SLSS
8” Rd. Ver. HS+
8” Rd. Ver. WS+
490
230
8.0
2.0
ZV925SLSS
8” Rd. Ver. HS+
8” Rd. Ver. WS+
490
230
8.0
2.0
ZV950SDSS
8” Rd Ver. HS+
8” Rd. Ver. WS+
690
330
6.0
1.3
ZV1050SFSS
8” Rd. Ver. HS+
8” Rd. Ver. WS+
1040
450
10.0
2.5
ZVC30LSS
8” Rd. Ver. BS+
8” Rd. Ver. WS+
640
250
14.0
3.5
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
GE INDUSTRIAL SYSTEMS
GE Industrial Systems
Bathroom – Exhaust Fans (all models)
BF50
BF50EM
@ 0.25” SP
BF60CP
BF70
BF75
BF80S
@ 0.25” SP
BF80UQ
BF85
BF85OK
BF100EM
BF100S
BF100UQ
BF110S
BF110UQ
BF120EM
BF125EM
BF135UQ
BF145EM
BF150
BF210UQ
BF230UQ
BFL70
BFL50UQ
BFL60UQ
BFL80UQ
@ 0.25” SP
BFL85
BFL85ADW
BFL85DRB
BFL85DRN
BFL85DRS
BFL85DRW
BFL85RCB
BFL85RCC
BFL85SNS
BFL85SLN
BFL85SLW
BFL100RNL
BFL100UQ
BFL125RNL
BFL125UQ
BFLH70L
50
3.0
50
38
0.5
50
70
70
3.0
5.0
5.0
80
68
1.0
28.1
80
70
70
100
80
80
110
110
120
100
110
120
120
210
210
70
50
50
1.5
5.0
4.0
3.5
1.0
1.5
1.5
2.0
4.0
3.5
2.0
4.0
4.0
2.0
2.0
4.0
3.0
3.0
25.3
80
70
1.0
70
70
70
70
70
70
70
70
70
70
70
100
100
100
100
70
4.0
2.5
4.0
4.0
4.0
4.0
4.0
4.0
2.5
4.0
4.0
3.5
2.5
3.5
2.5
3.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
28.1
24.2
25.3
27.8
Rev. 09/01/2012
Section 1-49
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
BFLH85L
BH70DB
BH70SB
BH85DB
BH85SB
SONES
70
70
70
70
70
WATTS
MODEL
OR SERIES
DETAILS
3.5
3.5
3.5
3.5
3.5
CFM**
SONES
WATTS
HAIER AMERICA
Haier
Kitchen Range Hoods – Ducted & Convertible
Other Rooms – Exhaust Fans (all models)
WF180
180
6.5
HHX1030
Ver. HS+
Ver. WS+
Ver. Rd. HS+
Ver. Rd. WS+
Hor. HS+
Hor. WS+
170
120
220
150
180
120
6.5
3.0
6.5
3.0
8.0
4.0
HHX2030
Ver. HS+
Ver. WS+
Ver. Rd. HS+
Ver. Rd. WS+
Hor. HS+
Hor. WS+
170
120
220
150
180
120
6.5
3.0
6.5
3.0
8.0
4.0
HDD300SS6
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
300
100
290
100
4.0
0.4
3.5
0.8
HHV2230DBBB Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
160
80
150
80
220
110
8.0
1.5
9.0
2.5
7.5
1.4
HHV2230DBWW Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
160
80
150
80
220
110
8.0
1.5
9.0
2.5
7.5
1.4
HHV2230SBSS
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
160
80
150
80
220
110
8.0
1.5
9.0
2.5
7.5
1.4
HHV3330DBBB Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
300
210
350
230
250
180
7.5
3.0
5.5
2.0
6.5
3.0
HHV3330DBWW Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
300
210
350
230
250
180
7.5
3.0
5.5
2.0
6.5
3.0
HHV3330SBSS
300
210
350
230
250
180
7.5
3.0
5.5
2.0
6.5
3.0
GENUIN ELECTRIC CO., LTD. GUANGDONG
Carnes Company
Bathroom – Exhaust Fans (all models)
VCDK005C
VCDK009C
50
110
1.0
1.5
25.1
45.6
GENUIN ELECTRIC CO., LTD. GUANGDONG
GNN
Bathroom – Exhaust Fans (all models)
BPT 12-02A
50
41
1.0
25.1
50
2.5
22.0
70
41
0.8
34.4
@ 0.25” SP
80
61
1.0
35.2
@ 0.25” SP
110
69
1.5
28.8
@ 0.25” SP
110
95
1.5
45.6
@ 0.25” SP
180
153
1.5
43.2
@ 0.25” SP
@ 0.25” SP
BPT 12-02D1
BPT 12-14A
BPT 15-14A1
BPT15-24A
BPT 15-24A1
BPT 18-44A
Inline Fans (all models)
DPT12.5-35D
180
GRAINGER INDUSTRIAL SUPPLY
Dayton
Whole House Comfort Ventilators
5NRR9
5NRT0
5NRT1
5NRT2
5NRT3
5NRT4
3300
4740
2620
5250
9200
6550
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
STATIC
*
PRESSURE**
Pascals (Pa) = in. wg x 250
110
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-50
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
HHX3030
STATIC
*
PRESSURE**
CFM**
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
HHX6030
300
100
290
100
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
HHX7030
300
100
290
100
Ver. HS+
Ver. WS+
LHV3330DBBB
SONES
390
120
WATTS
4.0
0.4
3.5
0.8
AF69G4
7.5
3.0
5.5
2.0
6.5
3.0
LHV3330DBWW Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
300
210
350
230
250
180
7.5
3.0
5.5
2.0
6.5
3.0
LHV3330SBSS
300
210
350
230
250
180
7.5
3.0
5.5
2.0
6.5
3.0
AF69G5
HS+
HS+
LS+
LS+
2.5
28.2
1.3
22.6
@ 0.25” SP
80
66
50
38
50
38
1.3
22.2
@ 0.25” SP
2.5
28.2
1.3
22.6
@ 0.25” SP
80
66
50
38
50
38
1.3
22.2
@ 0.25” SP
2.5
28.2
1.3
22.6
@ 0.25” SP
80
66
50
38
50
38
1.3
22.2
@ 0.25” SP
80
50
2.0
0.4
23.9
20.6
80
70
50
40
2.0
26.3
1.0
21.4
2.0
24.9
1.0
20.1
2.0
39.5
1.0
34.8
2.0
39.5
1.0
34.8
2.0
39.5
1.0
34.8
2.0
39.5
1.0
34.8
2.0
39.5
1.0
34.8
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
AF69G6 (Low Speed)
AF69L1
HS+
LS+
AF69L2
HS+
HS+
LS+
LS+
AF69L3
HANGZHOU AUPU BATHROOM & KITCHEN TECHNOLOGY
AUPU
AF912G1
HS+
HS+
LS+
LS+
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
HS+
@ 0.25” SP
LS+
Bathroom – Exhaust Fans (all models)
AF50L1
AF69G1
HS+
HS+
LS+
LS+
@ 0.25” SP
@ 0.25” SP
AF69G1 (Low Speed)
HS+
HS+
LS+
LS+
HS+
HS+
LS+
LS+
1.3
50
38
1.3
@ 0.25” SP
80
66
50
38
2.5
28.2
1.3
22.6
Pascals (Pa) = in. wg x 250
@ 0.25” SP
LS+
@ 0.25” SP
AF912G3
@ 0.25” SP
@ 0.25” SP
HS+
22.6
2.5
@ 0.25” SP
AF912G2
28.2
80
66
50
38
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
2.5
21.9
1.3
AF69G2 (Low Speed)
AF69G3
80
66
50
38
1.2
50
38
@ 0.25” SP
AF69G2
@ 0.25” SP
50
HS+
@ 0.25” SP
22.2
LS+
@ 0.25” SP
1.3
28.2
AF912G4
HS+
@ 0.25” SP
22.6
LS+
@ 0.25” SP
22.2
AF912G5
WATTS
22.2
AF69G5 (Low Speed)
HS+
HS+
LS+
LS+
SONES
1.3
AF69G4 (Low Speed)
AF69G6
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
HS+
HS+
LS+
LS+
CFM**
50
38
@ 0.25” SP
6.5
1.5
300
210
350
230
250
180
DETAILS
STATIC
*
PRESSURE**
AF69G3 (Low Speed)
4.0
0.4
3.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
Ver. Rd. HS+
Ver. Rd. WS+
MODEL
OR SERIES
HS+
@ 0.25” SP
LS+
@ 0.25” SP
70
60
50
40
110
95
70
56
110
95
70
56
110
95
70
56
110
95
70
56
110
95
70
56
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-51
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
AF912G6
DETAILS
STATIC
*
PRESSURE**
CFM**
HS+
@ 0.25” SP
LS+
@ 0.25” SP
AF912L1
AF912L2
AF912L3
HS+
HS+
LS+
LS+
HS+
HS+
LS+
LS+
HS+
HS+
LS+
LS+
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
@ 0.25” SP
SONES
110
95
70
56
100
90
80
60
100
85
70
60
WATTS
MODEL
OR SERIES
39.5
HOME DEPOT
1.0
34.8
Hampton Bay
2.0
37.8
1.0
34.1
249872
2.5
41.4
1.1
36.4
2.5
38.6
1.4
35.2
316622
< 0.3
23.4
317768
80
60
< 0.3
23.4
317898
@ 0.25” SP
80
60
< 0.3
23.4
985893
@ 0.25” SP
80
60
< 0.3
23.4
986755
@ 0.25” SP
80
60
< 0.3
23.4
986793
@ 0.25” SP
80
60
< 0.3
23.4
@ 0.25” SP
0.4
@ 0.25” SP
80
60
23.7
23.0
110
85
0.7
@ 0.25” SP
110
85
0.7
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
0.7
28.1
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
110
85
110
85
1.3
@ 0.25” SP
29.4
28.5
AFS80G4
AFS80G5
AFS80G6
AFS80L1
AFS110G1
AFS110G2
AFS110G3
AFS110G4
AFS110G5
AFS110G6
AFS110L1
80
58
0.5
1.0
9.0
11.3
140
122
1.5
45.1
@ 0.25” SP
140
124
1.5
50.0
@ 0.25” SP
110
90
1.2
32.1
@ 0.25” SP
70
64
4.0
50.0
@ 0.25” SP
110
89
1.0
34.7
@ 0.25” SP
@ 0.25” SP
80
58
0.5
1.0
9.0
11.3
50
27
<0.3
20.4
@ 0.25” SP
80
60
1.0
30.0
@ 0.25” SP
2.0
1.5
13.1
11.5
316183
80
60
AFS80G3
HOMEWERKS WORLDWIDE
Homewerks Worldwide
28.1
Bathroom – Exhaust Fans (all models)
28.1
7111-03-L
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
70
54
@ 0.25” SP
HOMEWERKS WORLDWIDE
Hoover
Bathroom – Exhaust Fans (all models)
7123-01
80
3.0
12.3
7125-03
100
1.2
30.3
@ 0.25” SP
50
36
1.0
1.2
6.4
6.3
@ 0.25” SP
70
54
2.0
1.5
13.1
11.5
7127-02
7127-03
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
WATTS
@ 0.25” SP
315888
@ 0.25” SP
AFS80G2
SONES
Bathroom – Exhaust Fans (all models)
@ 0.25” SP
AFS80G1
CFM**
2.0
100
90
80
70
@ 0-.25” SP
DETAILS
STATIC
*
PRESSURE**
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-52
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
7127-04
SONES
WATTS
@ 0.25”SP
80
56
<0.3
0.6
7.2
9.3
0.8
33.2
@ 0.25” SP
110
85
@ 0.25” SP
80
49
0.6
1.0
9.6
10.0
1.2
32.0
@ 0.25” SP
110
93
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
IT050RFL
23.6
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
70
56
1.0
34.8
@ 0.25” SP
80
80
80
1.0
1.1
1.4
34.1
36.4
35.2
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
110
95
2.0
39.5
@ 0.25” SP
100
100
100
2.0
2.5
2.5
37.8
41.1
38.6
80
60
<0.3
23.4
@ 0.25” SP
80
60
<0.3
23.4
@ 0.25” SP
80
60
<0.3
23.4
@ 0.25” SP
80
60
<0.3
23.4
@ 0.25” SP
80
60
<0.3
23.4
@ 0.25” SP
80
60
<0.3
23.4
@ 0.25” SP
80
60
0.4
@ 0.25” SP
23.7
23.0
IT080G1
7128-02
IT080G2
HUNTER FAN COMPANY
IT080G3
Hunter
IT080G4
Bathroom – Exhaust Fans (all models)
80202
80212
80213
80500
80705
80707
81001
81002
81003
81004
81021
81030
81050
82004
82020
82022
82029
82030
82031
82032
82040
82048
83001
90052
90053
90058
90064
70
80
80
70
70
70
70
70
70
70
90
90
90
70
70
80
70
70
90
110
70
70
110
80
80
80
100
1.5
2.0
2.0
0.8
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
1.1
2.5
2.5
2.5
2.0
0.8
1.0
1.4
0.8
2.0
3.0
2.5
2.5
2.5
2.5
27.1
21.1
IT080FL1
IT080FL2
IT080FL3
IT110F1
IT110F2
20.0
20.0
20.0
24.5
20.4
20.4
21.0
21.5
19.2
20.5
23.0
19.5
20.3
30.9
21.0
21.0
21.0
32.8
IT110G1
IT110G2
IT110G3
IT110G4
IT110FL1
IT110FL2
IT110FL3
ITS080F1
ITS080F2
INFINITECH, INC
ITS080FG1
Infinitech
ITS080FG2
Bathroom – Exhaust Fans (all models)
IT050F1
IT050F2
IT050FG1
IT050FG2
IT050FG3
IT050FG4
IT050FL1
IT050FL2
IT050FL3
IT050RF
50
50
50
50
50
50
50
50
50
50
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
1.3
1.3
1.3
1.3
1.3
1.3
0.4
1.0
1.0
1.1
22.6
22.6
22.6
22.6
22.6
22.6
20.6
21.4
20.1
23.6
WATTS
1.2
IT080F2
7128-01
SONES
50
IT080F1
7127-05
CFM**
ITS080FG3
ITS080FG4
ITS080FL1
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-53
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
ITS110F1
SONES
WATTS
110
85
0.7
28.1
@ 0.25” SP
0.7
28.1
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
110
85
110
85
0.7
28.1
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
110
85
0.7
28.1
@ 0.25” SP
110
85
0.7
@ 0.25” SP
28.1
28.0
ITS110F2
ITS110FG1
ITS110FG2
ITS110FG3
ITS110FG4
ITS110FL1
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
WATTS
Tuscany
Bathroom – Exhaust Fans (all models)
611-5000
611-5001
70
70
2.0
2.0
33.1
33.1
K-STAR INTERNATIONAL GROUP INC.
K-Star
Bathroom – Exhaust Fans (all models)
KV110A
110
88
1.0
26.2
@ 0.25” SP
110
88
1.0
32.5
@ 0.25” SP
110
88
1.0
26.0
@ 0.25” SP
<0.3
<0.3
<0.3
0.3
0.4
0.5
0.8
0.9
1.0
0.8
0.7
0.9
2.5
0.8
2.0
2.0
3.0
3.0
3.5
3.5
2.5
3.0
3.0
3.5
3.5
16.2
17.0
20.1
21.1
23.0
23.6
33.0
33.1
35.4
35.7
39.5
39.1
19.0
15.8
18.6
19.1
23.6
24.7
39.8
44.0
29.6
31.2
30.8
34.2
35.5
KV110LB
Jetko
SONES
KING OF FANS
KV110LA
JETKO IMPORT & EXPORT INC.
CFM**
Bathroom – Exhaust Fans (all models)
E110XB06
110
87
0.6
35.6
@ 0.25” SP
0.7
33.1
@ 0.25” SP
90
68
N090XB07
LONON INDUSTRY CO. LTD
Lonon
Bathroom – Exhaust Fans (all models)
KING OF FANS
King of Fans
Bathroom – Exhaust Fans (all models)
7122-02
70
65
4.0
45.2
@ 0.25” SP
70
56
1.3
33.0
@ 0.25” SP
80
60
1.0
27.1
@ 0.25” SP
80
58
1.0
27.1
@ 0.25” SP
100
75
1.2
30.3
@ 0.25” SP
110
85
0.8
33.2
@ 0.25” SP
110
93
1.2
32.0
@ 0.25” SP
BF70
BF80
BF80L
BF90
BF110
BF110L
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
QV50
QV50L
QV80
QV80L
QV90
QV90L
QV110
QV110L
QV130
QV130L
QV150
QV150L
V50
V50L
V70
V70L
V80
V80L
V90
V90L
V90Q
V100
V100L
V110
V110L
50
50
80
80
90
90
110
110
130
130
150
150
50
50
70
70
80
80
90
90
90
100
100
110
110
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-54
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
LOWE’S HOME IMPROVEMENT
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MAGNAVENT, INC.
Harbor Breeze
Fanam
Bathroom – Exhaust Fans (all models)
Bathroom – Exhaust Fans (all models)
100
75
1.2
30.3
70
2.0
33.1
EQC165 Combo
SQ140
SQ210
UQ100
UQ200
110
85
0.8
33.2
@ 0.25” SP
UQS130
110
93
1.2
32.0
@ 0.25” SP
110
1.2
70
54
7105-01-L
@ 0.25” SP
7105-02-L
7107-01-L
7108-01-L
7108-02-L
7111-03-L
@ 0.25” SP
34998
35482
141666
200364
200366
290996
290997
379396
@ 0.25” SP
398999
0056948
0056974
0057823
0158087
HTR-REV02-L
170
130
200
100
200
4.0
2.5
5.5
1.0
3.5
HS+
LS+
130
20
2.5
0.9
72.4
27.2
UQS150
HS+
LS+
130
20
2.5
0.9
72.4
27.2
32.6
UQS185
2.0
1.5
13.1
11.5
HS+
LS+
180
50
3.5
0.7
85.2
30.8
UQS225
240
6.5
119.3
70
70
70
80
100
50
90
2.0
1.5
2.0
2.0
2.0
1.5
2.5
28.8
27.1
28.8
20.9
31.1
70
54
2.0
1.5
13.1
11.5
80
110
110
90
70
80
3.0
1.2
1.2
1.2
2.0
3.0
12.3
33.3
32.6
30.2
33.1
12.3
Inline Fans (all models)
DQ210
DQ300
EDB409
R100
R110
R125
R150
R200
R225
R250
R315
@ 0.20” SP
@ 0.20” SP
@ 0.2” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
170
200
280
120
160
240
320
400
620
660
810
112
170
93.9
34.1
97.4
101
102
125
253
243
275
MAGNAVENT, INC.
Kanaire
MABE CANADA, INC.
Bathroom – Exhaust Fans (all models)
Mabe
Kitchen Range Hoods – Ducted & Convertible
TV337NBB
3 x 9 Ver. HS+
3 x 9 Hor. HS+
7” Rd. Ver. HS+
160
140
170
6.0
7.5
6.0
47.0
47.8
45.7
TV337NWW
3 x 9 Ver. HS+
3 x 9 Hor. HS+
7” Rd. Ver. HS+
160
140
170
6.0
7.5
6.0
47.0
47.8
45.7
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
EQC165 Combo
SQ140
SQ210
UQ100
UQ200
HS+
HS+
HS+
HS+
HS+
170
130
200
100
200
4.0
2.5
5.5
1.0
3.5
UQS130
HS+
LS+
130
20
2.5
0.9
72.4
27.2
UQS150
HS+
LS+
130
20
2.5
0.9
72.4
27.2
UQS185
HS+
LS+
180
50
3.5
0.7
85.2
30.8
UQS225
HS+
240
6.5
119
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-55
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MAICO ITALIA SPA
Elicent
Inline Fans (all models)
AXC100AES
AXC100B
AXC125AES
AXC125B
AXC150AES
AXC150BES
AXC200AES
AXC200BES
AXC250ES
AXC300AES
AXC300BES
130
140
150
160
190
260
300
520
550
700
910
43.3
83.4
44.4
85.4
46.8
89.2
84.5
188
197
206
312
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
A647
A647B
A664IC
A728N
B560
B660W
MM647
MM647B
MM664IC
MM667IC
MM698
MM698F
MM698WC
MM728
MM728NL
MM748
TC667
MM648
CFM**
SONES
50
50
50
100
70
70
50
50
50
60
70
70
70
100
100
70
70
60
WATTS
4.5
4.5
3.5
4.0
5.5
4.0
4.5
4.5
4.0
5.0
3.0
3.0
3.0
6.0
6.0
5.0
4.0
3.5
Inline Fans (all models)
MARLEY ENGINEERED PRODUCTS
Marley
IF110
@ 0.20” SP
@ 0.50” SP
100
68
IF175
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
170
144
87
IF275
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
230
176
89
74.7
74.4
71.0
IF400
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
450
353
220
140.0
148.0
148.0
IF500
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
500
420
275
133.0
144.0
151.0
Bathroom – Exhaust Fans (all models)
761
763
782W
1001
1001BR
1001F
1100W
6060
6060L
6060RL
6080
6080L
6080RL
6100
6100RL
6100RLX2
6100X2
7100A
7100LA
7150FL
7150
7150L
768IC
70
90
60
100
100
100
80
60
60
60
80
80
80
110
110
110
110
100
100
100
150
150
90
2.0
3.0
4.5
4.5
4.5
4.5
4.0
4.0
4.0
3.5
3.0
2.5
2.5
4.0
4.0
4.0
4.0
1.5
1.5
2.5
3.5
3.0
3.0
80
72
1.0
@ 0.25” SP
80
73
1.0
@ 0.25” SP
90
90
1.0
1.0
140
111
2.5
46.3
@ 0.25” sp
140
107
2.5
@ 0.25” SP
48.6
46.6
8080ES
8080FL
8090
8090L
8140ES
8140FL
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
19.4
19.6
Kitchen - Exhaust Fans
69.3
69.3
69.3
69.3
68.4
68.4
760L
898L
899L
1047
1080
200
200
200
460
280
5.5
7.0
7.0
7.0
5.5
Powered Attic Ventilators
32.1
AGV14
ASRV14
GV16
1040
1060
1520
Whole-House Comfort Ventilators
31.6
26.8
2438
3038R
3638R
A20DD
3900
5500
7100
2900
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-56
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
GM-280
GM-400
GM-500
MILANO ELECTRONICS LLC
Milano
SONES
260
360
450
WATTS
4.5
2.0
3.5
Bathroom – Exhaust Fans (all models)
TY-50-A
50
14
<0.3
17.6
@ 0.25” SP
NORTH AMERICAN RANGE HOODS, INC.
50
27
0.5
21.0
Cyclone Range Hoods
@ 0.25” SP
<0.3
17.6
@ 0.25” SP
50
14
80
60
0.7
30.0
@ 0.25” SP
1.0
30.0
@ 0.25” SP
90
67
80
60
0.7
30.0
@ 0.25” SP
80
56
1.0
25.2
@ 0.25” SP
100
74
1.0
36.8
@ 0.25” SP
100
74
1.0
36.8
@ 0.25” SP
TY-50-A (HD)
TY-50-B
TY-80-A
TY-80-A (HD)
TY-80-B
TY-80-S
TY-100-A
TY-100-B
Kitchen Range Hoods – Ducted & Convertible
BOX-2000
HS+
WS+
LS+
540
280
210
8.0
7.0
5.0
CY1000
HS+
WS+
LS+
540
280
210
8.0
7.0
5.0
NA930
HS+
WS+
LS+
540
280
210
8.0
7.0
5.0
ORBIT INDUSTRIES, INC
Orbit Fans
Bathroom – Exhaust Fans (all models)
OD50
NATIONAL HVAC PRODUCTS, INC.
190
250
60
90
110
110
110
220
230
2.5
4.5
0.9
1.0
1.5
1.5
2.0
5.0
5.0
58.0
36.4
120
200
Pascals (Pa) = in. wg x 250
31.6
28.7
90
76
1.0
@ 0.25” SP
28.3
26.1
90
75
0.7
@ 0.25” SP
32.1
29.5
100
84
1.2
@ 0.25” SP
29.2
27.2
110
93
1.5
@ 0.25” SP
30.5
28.5
110
96
1.2
@ 0.25” SP
33.7
31.9
120
105
2.0
@ 0.25” SP
32.1
30.6
50
60
70
80
50
3.0
4.0
3.5
4.0
2.5
36.5
42.0
27.1
30.8
19.9
OD100
OD110
OD110L
OD120
OE50
OE60
OE70
OE80
OEP50
Other Rooms – Exhaust Fans (all models)
** CONVERSIONS:
80
64
0.5
@ 0.25” SP
OD90L
160
130
180
260
290
330
470
610
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
27.9
26.1
OD90
27.3
Inline Fans (all models)
GM-130
GM-180
80
67
0.8
@ 0.25” SP
OD80L
Bathroom – Exhaust Fans (all models)
DBF150
IL-130
IL-180
IL-280
IL-290
IL-400
IL-500
IL-700
31.7
28.5
OD80
Zonex
GI-70X2
GI-100x2
GM-60
GM-90
GM-120
GM-120FR
GM-120P
GM-220
GM-230
50
30
<0.3
@ 0.25” SP
1.0
2.5
77.9
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-57
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
OEP80
SONES
80
63
1.3
@ 0.25” SP
80
70
1.0
@ 0.25” SP
90
76
1.5
@ 0.25” SP
90
75
110
83
1.1
OEP80L
OEP90
OEP90L
@ 0.25” SP
OEP110
@ 0.25” SP
OEP110L
@ 0.25” SP
110
93
2.0
1.0
WATTS
MODEL
OR SERIES
DETAILS
31.2
30.9
OD-9007HSLT
29.2
28.8
OD-9007LT
24.5
22.8
OD-12012
24.5
22.7
27.0
25.3
OD-12012HS
27.3
25.9
STATIC
*
PRESSURE**
CFM**
WATTS
90
68
0.7
33.1
@ 0.25” SP
90
68
0.7
33.1
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
OD-12012HSLT
`
OD-12012LT
OD-12012MS
ORTECH INDUSTRIES INC
SONES
Ortech.
OSTBERG AMERICAS INC
Bathroom – Exhaust Fans (all models)
OD-1106
0.6
35.6
@ 0.25” SP
110
87
0.6
35.6
@ 0.25” SP
110
87
110
87
0.6
@ 0.25” SP
90
67
0.3
31.5
@ 0.25” SP
90
67
0.3
31.5
@ 0.25” SP
90
68
0.7
33.1
@ 0.25” SP
90
68
0.7
33.1
@ 0.25” SP
90
68
0.7
33.1
@ 0.25” SP
90
67
0.3
31.5
@ 0.25” SP
90
67
0.3
31.5
@ 0.25” SP
0.3
31.5
@ 0.25” SP
90
67
90
68
0.7
33.1
@ 0.25” SP
90
68
0.7
33.1
@ 0.25” SP
Ostberg Americas Inc.
Inline Fans (all models)
OD-1106HS
OD-1106LT
OD-8003
OD-8003LT
OD-8007
OD-8007HS
OD-8007LT
OD-9003
OD-9003HS
35.6
CK 4A
CK 4C
CK 5A
CK 5C
CK 6B
CK 6C
CK 8A
CK 8B
CK 10A
CK 10C
CK 12B
CK 12C
LPK4A
LPK4B
LPK5A
LPK5B
LPK6B
LPK6D
LPKB5A
LPKB5B
LPKB6B
LPKB6C
LPKB8A
LPKB8B
100
150
120
210
250
440
560
580
530
660
850
900
80
150
110
190
230
270
130
200
210
310
460
500
47.4
71.6
76.9
141
145
199
120
190
160
240
260
470
560
590
510
50.5
79.4
49.2
79.1
76.2
117
127
177
121
78.4
76.8
134
133
186
124
186
203
250
Remote Exterior Mounted Ventilators
OD-9003LT
OD-9007
OD-9007HS
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
KV4A
KV4C
KV5A
KV5C
KV6B
KV6C
KV8A
KV8B
KV10A
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-58
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
KV10C
KV12B
KV12C
RS5A
RS5C
RS6A
RS6C
TKC300A
TKC300B
TKC300C
TKC400A
TKC400B
TKC400C
TKK300A
TKK300C
TKK400A
TKK400B
TKK400D
SONES
640
830
880
90
140
290
390
160
210
240
380
470
540
180
270
380
490
750
WATTS
176
205
254
50.0
77.0
97.1
139
48.3
65.7
75.0
98.0
137
192
50.0
75.0
96.0
131
214
MODEL
OR SERIES
DETAILS
FV-08VFL3
STATIC
*
PRESSURE**
CFM**
3” Duct
0.5
0.8
0.5
0.8
28.4
28.0
28.8
28.6
@ 0.25” SP
70
56
80
62
0.8
1.0
0.9
1.1
24.3
24.0
24.5
24.3
@ 0.25” SP
80
79
<0.3
0.4
7.0
11.0
@ 0.25” SP
80
79
<0.3
0.6
7.4
12.4
80
81
70
71
60
60
50
50
40
40
30
32
<0.3
0.7
<0.3
0.7
<0.3
0.6
<0.3
0.5
<0.3
0.5
< 0.3
0.5
10.7
16.4
8.7
14.2
7.2
11.7
6.3
10.4
5.6
9.2
4.6
8.2
80
79
70
75
60
59
50
54
40
39
30
32
<0.3
0.4
<0.3
0.4
<0.3
0.3
<0.3
0.3
<0.3
<0.3
<0.3
<0.3
7.0
11.0
5.4
10.1
5.0
8.7
4.3
7.5
3.7
6.6
3.2
5.8
80
79
70
78
60
60
50
52
40
42
30
35
<0.3
0.6
<0.3
0.6
<0.3
0.5
<0.3
0.5
<0.3
0.5
<0.3
0.5
7.4
12.4
6.0
11.6
5.3
9.0
4.2
7.8
3.8
6.7
3.5
6.2
80
82
70
71
60
60
50
50
40
41
30
32
<0.3
0.7
<0.3
0.7
<0.3
0.6
<0.3
0.5
<0.3
0.5
< 0.3
10.6
16.2
8.6
14.0
7.0
11.8
6.1
10.2
5.6
9.2
4.7
8.2
4” Duct
@ 0.25” SP
3” Duct
@ 0.25” SP
4” Duct
FV-08VK3
FV-08VKL3
FV-08VKM2
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
PANASONIC
@ 0.25” SP
50 CFM speed
Panasonic
@ 0.25” SP
40 CFM speed
@ 0.25” SP
Bathroom – Exhaust Fans (all models)
FV-05VF2
30 CFM speed
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
FV-05VFL2
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
FV-05VFL3
3” Duct
50
35
50
35
<0.3
16.6
16.5
16.6
16.5
<0.3
15.9
15.8
15.9
15.8
@ 0.25” SP
50
34
50
30
0.4
0.8
<0.3
0.7
16.1
16.0
16.3
16.0
@ 0.25” SP
50
54
<0.3
0.3
4.3
7.5
@ 0.25” SP
50
36
<0.3
0.4
11.1
11.7
@ 0.25” SP
50
38
0.4
1.0
17.6
17.3
70
53
80
60
0.8
1.1
0.8
1.0
24.3
24.0
24.5
24.3
70
57
80
63
0.6
29.4
28.7
29.7
29.1
@ 0.25” SP
3” Duct
@ 0.25” SP
4” Duct
FV-05VK3
FV-05VQ5
FV-05VS1
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
FV-08VFL2
15.0
14.8
15.0
14.7
<0.3
0.5
<0.3
0.4
@ 0.25” SP
FV-08VF2
0.5
1.1
0.4
0.9
50
35
50
35
4’ Duct
FV-05VFM2
50
31
50
30
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
0.5
@ 0.25” SP
FV-08VKM3
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
40 CFM speed
@ 0.25” SP
30 CFM speed
@ 0.25” SP
FV-08VKML3
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
40 CFM speed
@ 0.25” SP
30 CFM speed
@ 0.25” SP
FV-08VKS2
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
40 CFM speed
@ 0.25” SP
30 CFM speed
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
70
60
80
67
@ 0.25” SP
FV-08VFM2
SONES
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-59
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
FV-08VKS3
DETAILS
STATIC
*
PRESSURE**
CFM**
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
40 CFM speed
@ 0.25” SP
30 CFM speed
@ 0.25” SP
SONES
WATTS
80
79
70
75
60
59
50
54
40
39
30
32
<0.3
0.4
<0.3
0.4
<0.3
0.3
<0.3
0.3
<0.3
<0.3
<0.3
<0.3
7.0
11.0
5.4
10.1
5.0
8.7
4.3
7.5
3.7
6.6
3.2
5.8
80
79
70
78
60
60
50
52
40
42
30
35
<0.3
0.6
<0.3
0.6
<0.3
0.5
<0.3
0.5
<0.3
0.5
<0.3
0.5
7.4
12.4
6.0
11.6
5.3
9.0
4.2
7.8
3.8
6.7
3.5
6.2
MODEL
OR SERIES
DETAILS
FV-11VFL2
STATIC
*
PRESSURE**
CFM**
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
FV-11VFL3
3” Duct
80 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
60 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
40 CFM speed
@ 0.25” SP
30 CFM speed
@ 0.25” SP
FV-08VQ5
@ 0.25” SP
FV-08VQC5
@ 0.25” SP
FV-08VQCL5
@ 0.25” SP
FV-08VQL5
@ 0.25” SP
80
62
80
59
80
62
80
62
<0.3
0.4
<0.3
<0.3
<0.3
0.4
<0.3
0.4
14.7
14.5
15.8
15.6
17.5
17.6
14.9
14.7
@ 0.25” SP
80
66
0.8
0.7
@ 0.25” SP
110
89
110
89
0.6
1.0
0.7
1.0
30.7
30.5
30.6
30.5
@ 0.25” SP
110
108
0.7
1.1
12.5
18.0
@ 0.25” SP
110
91
<0.3
0.5
21.1
20.7
@ 0.25” SP
110
91
0.3
0.5
24.3
24.2
@ 0.25” SP
110
89
0.7
0.7
25.2
25.0
@ 0.25” SP
110
90
0.5
0.6
23.4
23.0
@ 0.25” SP
130
135
<0.3
0.7
11.6
21.1
@ 0.25” SP
130
137
0.8
1.3
14.2
24.2
130
135
110
111
90
93
70
71
50
53
<0.3
0.7
<0.3
0.6
<0.3
0.6
<0.3
0.4
<0.3
<0.3
11.6
21.1
8.7
15.1
6.0
12.1
4.1
9.6
2.4
5.8
130
137
110
115
90
91
70
69
50
57
0.8
1.3
0.6
1.2
0.3
1.1
<0.3
0.9
<0.3
0.8
14.2
24.2
10.7
19.4
7.8
14.9
5.9
10.5
4.1
8.5
@ 0.25” SP
FV-11VH2
@ 0.25” SP
FV-11VKL3
FV-11VQ5
FV-11VQC5
FV-11VQCL5
FV-11VQL5
FV-13VK3
FV-13VKL3
20.5
19.5
130 CFM speed
110 CFM speed
@ 0.25” SP
90 CFM speed
FV-08VS1
@ 0.25” SP
80
71
1.3
1.5
27.4
27.6
@ 0.25” SP
80
67
1.3
1.5
24.4
24.9
@ 0.25” SP
80
67
1.3
1.5
24.6
25.0
@ 0.03” SP
70
1.1
18.0
@ 0.25” SP
70 CFM speed
@ 0.25” SP
FV-08VSL1
FV-08VSL2
50 CFM speed
@ 0.25” SP
FV-13VKML3
130 CVM speed
@ 0.25” SP
110 CFM speed
FV-08WQ1
@ 0.25” SP
90 CFM speed
FV-10VS1
@ .25” SP
100
90
1.5
1.5
36.4
36.1
@ 0.25” SP
100
90
1.5
2.5
36.6
36.3
@ 0.25” SP
100
90
1.5
2.5
36.6
36.3
90
78
110
94
1.5
2.0
1.5
1.5
33.8
33.5
33.5
33.2
@ 0.25” SP
70 CFM speed
@ 0.25” SP
FV-10VSL1
FV-10VSL2
FV-11VF2
3” Duct
@ 0.25” SP
4” Duct
@ 0.25” SP
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
1.3
50 CFM speed
@ 0.25” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
33.3
32.8
33.6
33.2
33.8
33.5
33.0
32.6
@ 0.25” SP
FV-08VRL1
1.5
1.5
2.0
1.3
1.5
4” Duct
FV-13VKM3
90
78
110
96
WATTS
90
78
110
96
@ 0.25” SP
FV-11VHL2
FV-08VKSL3
SONES
Rev. 09/01/2012
Section 1-60
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
FV-13VKS3
DETAILS
STATIC
*
PRESSURE**
CFM**
130 CFM speed
SONES
WATTS
130
135
110
111
90
93
70
71
50
53
<0.3
0.7
<0.3
0.6
<0.3
0.6
<0.3
0.4
<0.3
<0.3
11.6
21.1
8.7
15.1
6.0
12.1
4.1
9.6
2.4
5.8
@ 0.25” SP
130
137
110
115
90
91
70
69
50
57
0.8
1.3
0.6
1.2
0.3
1.1
<0.3
0.9
<0.3
0.8
14.2
24.2
10.7
19.4
7.8
14.9
5.9
10.5
4.1
8.5
150
123
0.6
@ 0.25” SP
31.4
30.2
@ 0.25” SP
150
127
<0.3
0.5
28.4
27.3
@ 0.25” SP
150
128
0.9
1.0
31.8
30.9
FV-10NLF1
@ 0.20” SP
@ 0.30” SP
@ 0.40” SP
120
105
82
36.2
35.0
33.5
FV-20NLF1
@ 0.20” SP
@ 0.30” SP
@ 0.40” SP
240
220
200
55.5
53.5
51.1
FV-30NLF1
@ 0.20” SP
@ 0.30” SP
@ 0.40” SP
340
322
302
95.2
93.5
91.5
FV-40NLF1
@ 0.20” SP
@ 0.30” SP
@ 0.40” SP
440
421
407
136
132
130
@ 0.25” SP
110 CFM speed
@ 0.25” SP
90 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
50 CFM speed
@ 0.25” SP
FV-13VKSL3
130 CVM speed
@ 0.25” SP
110 CFM speed
@ 0.25” SP
90 CFM speed
@ 0.25” SP
70 CFM speed
@ 0.25” SP
50 CFM speed
FV-15VQ4
6” Duct
FV-15VQ5
FV-15VQL5
Inline Fans (all models)
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
PRIME INDUSTRIAL PRODUCTS INC.
Ekolos
Bathroom – Exhaust Fans (all models)
FQB50
FQB70
FQB90
FQB110
FQB130
FVB50
50
70
90
110
130
50
<0.3
<0.3
0.8
1.1
1.5
0.8
24.7
24.5
28.4
35.1
40.8
27.7
<0.3
<0.3
0.8
1.1
1.5
0.8
24.7
24.5
28.4
35.1
40.8
27.7
PRIME INDUSTRIAL PRODUCTS INC.
PRIME
Bathroom – Exhaust Fans (all models)
PME 50
PME 70
PME 90
PME 110
PME130
PQ 50
50
70
90
110
130
50
Inline Fans (all models)
FV-11VK3
110
112
0.3
0.8
11.5
16.2
0.8
1.4
2.0
@ 0.25” SP
190
145
290
257
43.7
42.9
64.0
62.0
@ 0.25” SP
390
359
3.0
3.0
@ 0.25” SP
FV-20VQ3
@ 0.25” SP
FV-30VQ3
FV-40VQ3
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
Pascals (Pa) = in. wg x 250
PIL 150
PIL 200
PIL 250
PIL 300
PIL 550
PIL 600
PIL 850
120
180
240
210
470
590
720
80.4
105
101
91.7
238
232
210
PROGRESS LIGHTING
Progress Lighting
Bathroom – Exhaust Fans (all models)
Other Rooms – Exhaust Fans (all models)
** CONVERSIONS:
MODEL
OR SERIES
112
110
PV-008-09STRWB
70
56
1.3
33.0
@ 0.25” SP
70
56
1.3
33.0
@ 0.25” SP
80
58
1.0
27.1
@ 0.25” SP
80
1.0
27.2
PV-008-74STRWB
PV020-30
PV021-30WB
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-61
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
QINGDAO XINGBANG
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
SE110
Sterling
0.6
35.8
110
87
0.6
35.8
@ 0.25” SP
110
87
0.6
35.8
@ 0.25” SP
110
87
0.6
35.8
@ 0.25” SP
110
87
0.6
35.8
@ 0.25” SP
110
87
0.6
35.8
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
120
100
1.2
36.6
@ 0.25” SP
150
131
1.1
41.2
@ 0.25” SP
150
131
1.1
41.2
@ 0.25” SP
150
131
1.1
41.2
@ 0.25” SP
SN50
50
0.6
16.2
SN60
60
1.4
64.6
80
50
1.1
28.6
SN90
90
1.5
65.8
SN90L
90
3.0
SN100
100
1.5
SN100L
100
4.0
SN110
110
1.5
SN110L
110
1.5
SE110L
0.3
31.8
@ 0.25” SP
0.7
33.3
@ 0.25” SP
90
68
E080XB08
E110XB07
SE110LH
SE110X
110
87
0.6
@ 0.25” SP
120
100
1.2
@ 0.25” SP
N080XB10
80
0.7
N090XB30
90
3.0
N110XB15
N110XB40
110
100
1.5
4.0
70
3.5
63.0
90
68
0.7
33.3
@ 0.25” SP
90
68
0.7
@ 0.25” SP
90
68
0.7
@ 0.25” SP
80
60
0.3
@ 0.25” SP
90
67
0.3
31.5
@ 0.25” SP
90
68
0.7
33.3
@ 0.25” SP
0.7
33.3
@ 0.25” SP
90
68
0.7
33.3
@ 0.25” SP
90
68
90
68
0.7
33.3
@ 0.25” SP
0.3
31.8
@ 0.25” SP
90
67
90
67
0.3
31.8
@ 0.25” SP
90
67
0.3
31.8
@ 0.25” SP
100
87
0.6
35.8
@ 0.25” SP
E110XB07A
S70
SE80
SE80H
SE80L
SE80Q
SE80QL
SE90
SE90H
SE90L
SE90LH
SE90Q
SE90QH
SE90QL
SE100
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
35.8
36.6
SE110XL
SE120
SE120H
SE120L
33.3
33.3
31.8
WATTS
110
87
SE110H
90
60
SONES
@ 0.25” SP
Bathroom – Exhaust Fans (all models)
E080XB03
CFM**
SE120LH
SE120M
SE140
SE140L
SE150
SN80
@ 0.25” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
65.8
Rev. 09/01/2012
Section 1-62
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
RENEWAIRE LLC
RenewAire
Bathroom – Exhaust Fans (all models)
V50
50
31
<0.3
@ 0.25” SP
12.9
11.8
80
60
<0.3
@ 0.25” SP
16.1
15.2
110
93
0.8
@ 0.25” SP
24.2
23.0
150
110
<0.3
@ 0.25” SP
32.7
32.0
V80
V110
V150
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
EB-70
EB-80
EB-100
QB-80
QB-80LT
QB-100
QB130
QB-150
QCF-95
QCF-125
QCF-125CO
QCF-145
QCF170
QCF-200
QCF-300
QCF-400
QCF-500
QCF-600
QCF-800
CFM**
SONES
60
80
100
60
60
100
110
130
80
110
110
130
140
200
280
350
500
640
690
REVERSOMATIC HEATING AND MANUFACTURING, LTD.
WATTS
3.5
2.5
3.0
2.0
0.6
2.5
2.0
4.5
1.5
2.0
2.0
2.5
2.5
4.0
4.0
4.0
4.0
5.5
6.0
39.5
31.5
REVERSOMATIC HEATING AND MANUFACTURING, LTD
Air Specialty Canada, Ltd.
Marley
Inline Fans (all models)
Other Rooms – Exhaust Fans (all models)
SMP260
SMP350
200
290
610FRD
650FRD
680FRD
Kitchen Range Hoods – Ducted & Convertible
2000-200
4000-200
200
200
5.5
5.5
100
40
80
3.0
2.5
2.5
REVERSOMATIC HEATING AND MANUFACTURING, LTD.
Reversomatic
REVERSOMATIC HEATING AND MANUFACTURING, LTD.
Bathroom – Exhaust Fans (all models)
Apollo
CF-170ES
Bathroom – Exhaust Fans (all models)
CF-170BC
160
131
1.5
@ 0.25” SP
42.2
38.9
0.6
30.5
@ 0.25” SP
60
40
1.3
35.4
@ 0.25” SP
120
103
1.5
@ 0.25” SP
100
83
28.6
27.0
QB-80 BC
QCF-130 BC
QK-130 BC
160
131
1.5
@ 0.25” SP
42.2
38.9
60
43
2.0
40.0
@ 0.25” SP
80
69
0.3
@ 0.25” SP
22.8
22.3
100
88
0.9
@ 0.25” SP
27.3
27.2
110
95
1.2
@ 0.25” SP
33.2
30.4
110
90
2.0
@ 0.25” SP
36.0
35.1
120
103
1.3
@ 0.25” SP
35.4
34.0
100
83
1.5
@ 0.25” SP
28.6
27.0
QB-80
QCF-80ES
QCF-80ES (S)
QCF-110ES
QCF-125ES
Inline Fans (all models)
TLD-200BC
220
74.4
Other Rooms – Exhaust Fans (all models)
EB-50
EB-60
** CONVERSIONS:
QK-130ES
40
40
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
Pascals (Pa) = in. wg x 250
QCF-130ES
2.5
2.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-63
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
QK-150ES
SONES
WATTS
MODEL
OR SERIES
DETAILS
130
116
1.0
@ 0.25” SP
38.4
37.3
3000-300
4000-200
150
132
0.9
40.4
39.0
4000-250ES2
@ 0.25” SP
1.5
@ 0.25” SP
180
157
QK-160ES
QK-180ES
50.9
50.4
Ver. HS+
Ver. HS+
Ver. WS+
Hor. HS+
Hor. HS+
Hor. WS+
STATIC
*
PRESSURE**
CFM**
@ 0.25” SP
@ 0.25” SP
SONES
WATTS
250
200
6.0
5.5
210
166
120
230
183
100
3.5
2.0
3.0
1.5
76.8
73.4
38.7
77.3
74.0
30.2
Inline Fans (all models)
DK260
RI150
RI200
RI250
SMP260
SMP350
TL-240
TL-240ES
TL-340
TLD200
TLD200BC
TLD200ES
TLD300
230
130
170
190
200
290
210
210
330
180
180
220
270
REVERSOMATIC HEATING AND MANUFACTURING, LTD.
Bathroom – Exhaust Fans (all models)
74.4
Kitchen - Exhaust Fans
QK-100
4.5
2.5
4.5
1.0
2.0
2.5
2.5
2.5
3.5
3.0
90
50
1.0
0.7
QB-100S
QCF-110
100
100
2.5
1.0
QCF-125
QCF-150
QCF-200
QCF-300
QCF-400
QCF-500
QCF-600
QCF-800
RS-85
RS-95
RS-90
RS-100
110
130
200
280
350
500
640
690
80
80
90
100
2.0
2.5
4.0
4.0
4.0
4.0
5.5
6.0
2.5
1.5
2.5
2.5
230
140
140
200
160
11.0
CF130
CF170
EB-45
EB-50
EB-55
EB-100
LSF80
HS+
LS+
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
19.0
50
39
2.0
@ 0.25” SP
35.4
34.9
80
59
0.3
@ 0.25” SP
22.8
21.0
110
90
1.0
@ 0.25” SP
27.4
26.5
110
90
1.0
@ 0.25” SP
27.4
26.5
170
152
1.5
@ 0.25” SP
46.8
45.6
210
181
3.0
72.2
@ 0.25” SP
SA-90S
SA-90SM
SA-150S
SA-200S
RHEEM
Rheem
Integrated Supply & Exhaust Ventilators
49.0
Kitchen Range Hoods – Ducted & Convertible
1000-225
1000-160
1000-160N
1000-200
2000-200
60
39
<0.3
@ 0.25” SP
SA-70D
40
160
80
110
140
40
40
60
100
HS+
LS+
SA-50D
SA-50E
130
Other Rooms – Exhaust Fans (all models)
B50-P
CF100
Softaire
71.2
106
8.0
6.0
84-HRV-HEPA3 Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
277
110
252
103
237.0
237.0
229.0
229.0
84-HRV-HEPA4 Gross Airflow-Recirculation @ 0.20” SP
Net Ventilation Airflow
@ 0.20” SP
Gross Airflow-Recirculation @ 0.40” SP
Net Ventilation Airflow
@ 0.40” SP
270
122
254
113
227.0
227.0
224.0
224.0
50.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-64
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
RONA
MODEL
OR SERIES
350
250
180
7.0
4.5
2.0
190
145
120
SOLER & PALAU
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
100
88
78
PV-100X
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
130
115
101
PV-125
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
86
69
PV-125X
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
170
144
116
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
200
161
PV-150X
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
350
305
260
PV-200
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
380
325
274
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
490
436
366
PV-250
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
510
457
410
PV-250X
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
570
525
478
PV-315
HS+
HS+
HS+
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
620
572
525
PVR-100
HS+
@ 0.20 » SP
170
PV-150
PV-200X
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
70
60
23.5
21.4
TD100X
HS+
LS+
@ 0.20” SP
@ 0.20” SP
100
60
27.0
18.8
TD100XS
5” duct HS+
5” duct LS+
4” duct HS+
4” duct LS+
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
150
80
100
60
35.4
20.0
34.5
19.8
TD125
HS+
LS+
@ 0.20” SP
@ 0.20” SP
180
110
42.9
27.1
TD150
HS+
LS+
@ 0.20” SP
@ 0.20” SP
260
170
62.7
51.6
TD150S
HS+
LS+
@ 0.20” SP
@ 0.20” SP
300
190
64.5
54.5
TD200
HS+
LS+
@ 0.20” SP
@ 0.20” SP
470
390
98.6
81.3
TD200S
HS+
LS+
@ 0.20” SP
@ 0.20” SP
480
350
123
110
TD250
HS+
LS+
@ 0.20” SP
@ 0.20” SP
690
430
240
160
TD315
HS+
LS+
@ 0.20” SP
@ 0.20” SP
950
600
315
207
@ 0.20” SP
100
90
@ 0.20” SP
160
154
@ 0.20” SP
220
203
@ 0.20” SP
330
314
@ 0.20” SP
390
373
Inline Fans (all models)
HS+
HS+
HS+
SONES
@ 0.20” SP
@ 0.20” SP
Soler & Palau
PV-100
CFM**
HS+
LS+
Kitchen Range Hoods – Ducted & Convertible
Ver. Rd. HS+
Ver. Rd. MS+
Ver. Rd. WS+
DETAILS
TD100
Uberhaus Design
FSD-B02
STATIC
*
PRESSURE**
Remote Exterior Mounted Ventilators
SWF-100
SWF-100X
125
SWF-150
SWF-150X
SWF-200
175
SPRUCE ENVIRONMENTAL TECHNOLOGIES
HomeAire
200
98.0
Inline Fans (all models)
ADC-4
@ 0.20” SP
@ 0.50” SP
110
70
20.8
20.7
ADC-5
@0.20” SP
@0.50” SP
@1.00” SP
150
126
82
71.2
69.1
63.0
ADC-6
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
230
176
89
74.7
74.4
71.0
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-65
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
SPRUCE ENVIRONMENTAL TECHNOLOGIES
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
110
70
20.8
20.7
RP145
@0.20” SP
@0.50” SP
@1.00” SP
150
126
82
71.2
69.1
63.0
RP260
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
230
176
89
74.7
74.4
71.0
RP265
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
300
247
176
128
128
127
RP380
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
450
353
220
140.0
148.0
148.0
280
238
164
84.2
88.2
89.0
RL450
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
460
371
241
130
150
150
RL500
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
500
419
275
133
143
153
RL600
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
610
511
332
199
206
215
RV100
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
100
71
18
RV125
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
110
98
71
RV150
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
140
119
76
RV175
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
160
136
80
RV200
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
170
144
87
RV250
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
190
149
93
SPRUCE ENVIRONMENTAL TECHNOLOGIES
Spruce
Inline Fans (all models)
RB110
@ 0.20” SP
@ 0.50” SP
100
68
19.4
19.1
RB275
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
230
176
89
74.7
74.4
71.0
RB300
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
270
211
135
86.3
86.7
84.5
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
300
247
176
128
128
127
RB400
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
450
353
220
140
148
148
RB500
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
500
420
275
133
144
151
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
150
123
76
@ 0.20” SP
@ 0.60” SP
@ 1.00” SP
240
179
117
RB350
RL200
RL300
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
STELPRO DESIGN, INC.
Stelpro Design
Bathroom – Exhaust Fans (all models)
BSFQ 050
50
30
0.3
26.5
@ 0.25” SP
80
50
0.6
28.8
@ 0.25” SP
110
90
1.2
34.6
@ 0.25” SP
150
120
1.1
39.2
@ 0.25” SP
180
150
1.5
51.4
@ 0.25” SP
50
50
50
70
1.7
1.7
1.7
3.0
42.0
54.6
54.6
56.5
BSFQ 080
BSFQ 110
BSFQ 150L5
BSFQ 180L5
77.7
78.9
74.8
WATTS
@ 0.20” SP
@ 0.50” SP
@ 1.00” SP
Inline Fans (all models)
@ 0.20” SP
@ 0.50” SP
SONES
RL350
RadonAway
RP140
CFM**
SBF050
SBF050FR6
SBF050M06
SBF070
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-66
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SBF070FR6
SBF070M06
SBF090
SBF090FR6
SBF090M06
SBF120
SBFHL070
SBFL070
SPBF050
SPBF070
SQBF070
SQBF090
SQBF110
SQBF140
SQBF160
SQBFL110
SONES
70
70
90
90
90
120
70
70
50
70
70
90
110
140
160
110
3.0
3.0
2.5
2.5
2.5
4.0
5.0
3.0
0.6
1.5
<0.3
0.7
1.3
1.5
2.5
1.3
WATTS
73.1
73.1
31.1
90.2
90.2
42.4
45.9
56.5
25.5
26.1
17.2
23.7
28.2
41.0
54.0
27.3
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
Hor.
Ver.
Ver. R ound
175
170
210
7.5
7.0
8.0
320
283
249
123.0
123.0
123.0
CVS400A
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
380
352
324
156.0
157.0
157.0
DBF4XL
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
134
119
71.0
70.0
69.0
DBF4XLT
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
134
119
71.0
70.0
69.0
DBF110
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
133
113
80.0
79.0
78.0
DLX150FL
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
FG4
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
55
20.7
20.2
18.1
FG4XL
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
134
119
71.0
70.0
69.0
FG5
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
130
99
66
20.4
21.2
20.3
FG5XL
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
190
160
113
73.0
72.0
68.0
FG6
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
73.6
75.3
70.6
FG6M
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
370
317
224
122
124
124
FG 6M EC
@ 0.20” SP
330
79.1
FG6S
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
200
152
121
69.1
69.8
68.1
FG6XL
@ 0.20” SP
@ 0.40” SP
@ 1.25” SP
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
450
409
243
410
351
243
157
160
158
121
124
125
@ 0.20” SP
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
380
470
388
266
73.9
145
156
159
Whole House Comfort Ventilators
Superfan
@ 0.1” SP
@ 0.2” SP
@ 0.5” SP
1850
1810
1694
SYSTEMAIR MFG INC.
Fantech
Bathroom – Exhaust Fans (all models)
FQ80
80
60
<0.3
23.4
@ 0.25” SP
0.4
@ 0.25” SP
80
60
23.7
23.0
110
85
0.7
@ 0.25” SP
28.1
28.0
1.3
@ 0.25” SP
110
85
29.4
28.5
FQ80FL
FQ110
FQ110FL
FG8
Inline Fans (all models)
BFRK100
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
60
21.1
21.1
20.3
CVS275A
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
220
192
171
92.0
90.0
90.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
WATTS
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
SUPERFAN CORPORPORATION
Superfan
SONES
CVS300A
Kitchen Range Hoods – Ducted & Convertible
SHR200
CFM**
FG 8 EC
FG8XL
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-67
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
FG10
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
480
407
269
141
153
158
FGC10XL
@ 0.20” SP
@ 0.80” SP
@ 1.75” SP
560
472
306
200
211
209
FG 10 EC
@ 0.20” SP
460
93.6
FGC12
FG10XL
@ 0.20” SP
@ 0.80” SP
@ 1.75” SP
560
472
306
200
211
209
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
680
433
290
184
204
203
FGC12XL
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
680
433
290
184
204
203
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
880
670
504
306
326
330
FR100
FG 12 EC
@ 0.20” SP
600
142
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
90
71
52
19.4
19.1
18.1
FG12XL
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
880
670
504
306
326
330
FR110
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
133
113
80.0
79.0
78.0
FG 12XL EC
@ 0.20” SP
750
172
FR125
FGC 6M EC
@ 0.20”SP
330
75.3
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
120
88
47
18.0
18.0
17.0
FGC4
@ 0.20”SP
@ 0.40” SP
@ 0.60” SP
110
83
55
20.7
20.2
19.0
FR140
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
200
170
138
62.0
63.0
61.8
FGC5
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
130
99
66
20.4
21.2
20.3
FR150
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
72.5
73.0
73.5
FGC6
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
73.6
75.3
74.2
FR160
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
260
233
206
129.0
129.0
130.0
FGC6M
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
370
317
224
122
124
124
FR200
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
360
308
259
123
127
128
FGC6MEC
@ 0.20” SP
330
79.1
FR225
FGC6S
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
200
152
121
69.1
69.8
68.1
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
400
367
334
137
141
145
FR250
@ 0.20” SP
@ 0.40” SP
@ 1.25” SP
450
409
243
154
160
158
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
600
553
506
241.0
246.0
249.0
FX4
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
410
351
243
121
124
128
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
55
20.0
20.0
18.0
FX4XL
FGC 8 EC
@ 0.20” SP
380
73.9
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
150
134
119
71.0
70.0
69.0
FGC8XL
@ 0.20” SP
@ 0.60” SP
@ 1.25 “ SP
470
388
266
145
156
159
FX5
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
130
100
66
20.0
21.0
20.0
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
480
407
269
141
153
158
FX5XL
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
190
160
113
73.0
72.0
68.0
@ 0.20” SP
460
93.6
FG12
FGC6XL
FGC8
FGC10
FGC 10 EC
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-68
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
FX6
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
72.0
74.0
73.0
PB230FV-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
FX6XL
@ 0.20” SP
@ 0.40” SP
@ 1.25” SP
450
409
243
153.0
158.0
156.0
PB230H-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
FX8
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
410
351
243
119.0
122.0
122.0
PB230HV-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
FX8XL
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
470
388
266
142.0
153.0
157.0
PB270-2
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
73.6
75.3
74.2
FX10
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
480
407
269
138.0
150.0
155.0
PB270F-2
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
72.0
74.0
73.0
FX10XL
@ 0.20” SP
@ 0.80” SP
@ 1.75” SP
560
472
306
196.0
207.0
208.0
PB270FV-2
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
72.0
74.0
73.0
FX12
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
680
434
290
181.0
202.0
201.0
PB360-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
360
308
259
122.0
125.0
127.0
FX12XL
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
880
670
505
301.0
320.0
325.0
PB370-2
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
370
317
224
122
124
124
HP190
@ 0.20” SP
140
PB100
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
60
21.1
21.1
20.3
PBW110
@ 0.10” SP
@ 0.20” SP
@ 0.6” SP
120
112
37
18.2
18.6
17.6
PB100F
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
60
21.1
21.1
20.3
PBW110F
@ 0.10” SP
@ 0.20” SP
@ 0.40” SP
120
112
83
18.0
19.0
19.0
PB100H
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
60
21.1
21.1
20.3
PBW110H
@ 0.10” SP
@ 0.20” SP
@ 0.40” SP
120
112
83
18.0
19.0
19.0
PB110
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
55
20.7
20.2
19.0
RE54
@ 0.10” SP
@ 0.20” SP
@ 0.50” SP
100
91
61
18.4
18.7
18.3
PB110F
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
55
20.0
20.0
18.0
REC54
@ 0.10” SP
@ 0.20” SP
@ 0.50” SP
100
91
61
18.4
18.7
18.3
PB190
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
200
152
121
69.1
69.8
68.1
RVF4
@ 0.10” SP
@ 0.20” SP
@ 0.60” SP
120
112
37
18.2
18.6
17.6
PB230-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
RVF4XL
@ 0.10” SP
@ 0.40” SP
@ 0.60” SP
180
154
136
91.0
91.0
90.0
PB230F-2
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
RVF6
@ 0.10” SP
@ 0.40” SP
@ 0.60” SP
220
177
150
92.0
91.0
91.0
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Remote Exterior Mounted Ventilators
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-69
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
RVF6XL
@ 0.10” SP
@ 0.40” SP
@ 0.60” SP
360
315
285
149
153
156
K 12 EF
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
680
433
290
184
204
203
RVF8XL
@ 0.10” SP
@ 0.40” SP
@ 0.60” SP
410
348
312
152
154
154
K 12XL EC
@ 0.20” SP
750
172
K 12XL EF
@ 0.20” SP
@ 0.80” SP
@ 1.25” SP
880
670
504
306
326
330
K 150M EC
K 200 EC
K 250 EC
K 300 EC
K 300XL EC
KC 6M EC
KC 8 EC
KC 10 EC
KC 150M EC
KC 200 EC
KC 250 EC
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
@ 0.20” SP
330
380
460
600
750
330
380
460
330
380
460
75.3
70.4
89.2
135
164
79.1
73.9
89.2
75.3
70.4
89.2
Whole House Comfort Ventilators
1WHS24BD
1WHS24DD
1WHS30BD
1WHS30DD
1WHS36BD
1WHS42BD
2620
3300
5250
4740
9200
6550
SYSTEMAIR MFG INC.
Systemair
Remote Exterior Mounted Ventilators
Inline Fans (all models)
K 4 EF
@ 0.20” SP
@ 0.40” SP
@ 0.6” SP
110
83
55
20.7
20.2
19.0
K 5 EF
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
130
99
66
20.4
21.2
20.3
K 6 EF
@ 0.20” SP
@ 0.40” SP
@ 0.80” SP
270
232
164
73.6
75.3
74.2
K 6XL EF
@ 0.20” SP
@ 0.4” SP
@ 1.25” SP
450
409
243
157
160
158
K 6M EC
@ 0.20” SP
330
79.1
K 8 EC
@ 0.20” SP
380
73.9
K 8 EF
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
410
351
243
121
124
125
K 8XL EF
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
470
388
266
145
156
159
K 10 EC
@ 0.20” SP
460
93.6
RVF 4-EF
@ 0.10” SP
@ 0.20” SP
@ 0.60” SP
120
112
37
18.2
18.6
17.6
TFER 5-EF
@ 0.10” SP
@ 0.20” SP
@ 0.50” SP
100
91
61
18.4
18.7
18.6
TOTALINE
Totaline
Inline Fans (all models)
P451-REG100
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
110
83
60
21.1
21.1
20.3
P451-REG140
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
190
162
132
61.0
62.0
61.0
P451-DLX150
@ 0.20” SP
@ 0.40” SP
@ 0.60” SP
230
198
167
71.0
72.0
73.0
VENMAR VENTILATION, INC.
K 10 EF
@ 0.20” SP
@ 0.60” SP
@ 1.25” SP
480
407
269
141
153
158
K 10XL EF
@ 0.20” SP
@ 0.80” SP
@ 1.75” SP
560
472
306
200
211
209
@ 0.20” SP
600
142
K 12 EC
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Eurodesign
Kitchen Range Hoods – Ducted & Convertible
ED37030BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-70
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
ED65036SS
ED37030BLD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ED37030SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED600E30BLD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED600E30SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED600E30SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED600E30WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED600E30WHD Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
ED65030SS
Ver. HS+
Hor. HS+
490
600
10.5
10.5
ED65030SSD
Ver. HS+
Hor. HS+
490
600
10.5
10.5
ED65030WH
Ver. HS+
Hor. HS+
490
600
10.5
10.5
ED65030WHD
Ver. HS+
Hor. HS+
490
600
10.5
10.5
ED37030SSD
ED37030WH
ED37030WHD
ED600E30BL
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
STATIC
*
PRESSURE**
CFM**
Ver. HS+
Hor. HS+
SONES
490
600
WATTS
10.5
10.5
VENMAR VENTILATION, INC.
Kenmore
Kitchen Range Hoods
31000
31052
31053
31059
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
36.3
36.2
36.3
36.2
36.3
36.2
36.3
36.2
VENMAR VENTILATION, INC.
Venmar
Integrated Supply & Exhaust Ventilators
HEPA 2000
Gross Airflow-Recirculation
Net Ventilation Airflow
Gross Airflow-Recirculation
Net Ventilation Airflow
@ 0.20” SP
@ 0.20” SP
@ 0.40” SP
@ 0.40” SP
279
110
257
104
231.0
231.0
224.0
224.0
HEPA 3100
Gross Airflow-Recirculation
Net Ventilation Airflow
Gross Airflow-Recirculation
Net Ventilation Airflow
@ 0.20” SP
@ 0.20” SP
@ 0.40” SP
@ 0.40” SP
277
110
252
103
237.0
237.0
229.0
229.0
HEPA 4100
Gross Airflow-Recirculation
Net Ventilation Airflow
Gross Airflow-Recirculation
Net Ventilation Airflow
@ 0.20” SP
@ 0.20” SP
@ 0.40” SP
@ 0.40” SP
270
122
254
113
227.0
227.0
224.0
224.0
Kitchen Range Hoods – Ducted & Convertible
ESV1030SBL
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
121
36.3
123
36.2
Rev. 09/01/2012
Section 1-71
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
ESV1030BLD
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
ROV3530WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ESV1030SS
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
ROV3530WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ESV1030SSD
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
V1030BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
ESV1030WH
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
V1030SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
ESV1030WHD
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
V1030WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.8
ROV1530BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
V1030WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
ROV1530SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
V3030BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROV1530WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
V3030BLD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROV1530WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
240
100
280
100
6.5
0.9
5.5
0.9
V3030SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROV3530BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
V3030SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROV3530BLD
Ver. HS+
Ver. LS+
Hor. HS+
310
100
390
8.5
0.7
8.0
V3030WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
ROV3530SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
V3030WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
V40E30BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
380
140
510
150
8.0
1.0
7.5
1.0
ROV3530SSD
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
@ 0.02” SP
@ 0.02” SP
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-72
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
V40E30SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
380
140
510
150
8.0
1.0
7.5
1.0
C37030WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
V40E30SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
380
140
510
150
8.0
1.0
7.5
1.0
C37030WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
V40E30WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
380
140
510
150
8.0
1.0
7.5
1.0
C37030BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
C37030BLD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
C37030SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
C37030SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
310
100
390
100
8.5
0.7
8.0
0.7
C600E30BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
C600E30SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
C600E30SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
C600E30WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
120
670
120
10.5
0.7
10.0
0.5
C600M30BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
240
670
250
10.5
4.0
10.0
3.0
C600M30SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
240
670
250
10.5
4.0
10.0
3.0
C600M30SSD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
240
670
250
10.5
4.0
10.0
3.0
VENMAR VENTILATION, INC.
Venmar Connaisseur
Kitchen Range Hoods – Ducted & Convertible
C18030WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
C27030BL
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
C27030BLD
C27030SS
C27030SSD
C27030WH
C27030WHD
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
@ 0.02” SP
160
100
170
100
3.5
1.0
3.0
1.0
240
100
280
100
6.5
0.9
5.5
0.8
240
100
280
100
6.5
0.9
5.5
0.8
240
100
280
100
6.5
0.9
5.5
0.8
240
100
280
100
6.5
0.9
5.5
0.8
240
100
280
100
6.5
0.9
5.5
0.8
240
100
280
100
6.5
0.9
5.5
0.8
CC32I30SS
Ver. HS+
Ver. LS+
600
200
9.5
1.4
CC32I36SS
Ver. HS+
Ver. LS+
600
200
9.5
1.4
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
36.7
37.2
36.7
37.2
36.7
37.2
36.7
37.2
36.7
37.2
36.7
37.2
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-73
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
C600M30WH
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
240
670
250
10.5
4.0
10.0
3.0
CP300030SS
Hor. HS+
500
13.0
CPM1309SS
Ver. HS+
Ver. LS+
600
210
8.5
1.1
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
470
240
670
250
10.5
4.0
10.0
3.0
CPM1369SS
Ver. HS+
Ver. LS+
600
210
8.5
1.1
CPM1429SS
Ver. HS+
Ver. LS+
600
190
12.0
2.0
Ver. HS+
Hor. HS+
600
450
11.5
11.0
CPM2362SS
Ver. HS+
Ver. LS+
1000
370
12.0
1.5
Ver. HS+
Hor. HS+
600
450
11.5
11.0
CPM2422SS
Ver. HS+
Ver. HS+
1000
370
12.0
1.5
Ver. HS+
Hor. HS+
600
450
11.5
11.0
CPM2482SS
Ver. HS+
Ver. LS+
1080
410
10.5
1.5
Ver. HS+
Hor. HS+
600
450
11.5
11.0
ESC27030BL
C70030WH
Ver. HS+
Hor. HS+
600
450
11.5
11.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
C70036BL
Ver. HS+
Hor. HS+
600
450
11.5
11.0
ESC27030SS
C70036BY
Ver. HS+
Hor. HS+
600
450
11.5
11.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
ESC27030SSD
C70036WG
Ver. HS+
Hor. HS+
600
450
11.5
11.0
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
C70036WH
Ver. HS+
Hor. HS+
600
450
11.5
11.0
ESC27030WH
CC700I30BL
Ver. HS+
600
10.5
Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
CC700I30GY
Ver. HS+
600
10.5
CC700I30WG
CC700I30WH
Ver. HS+
Ver. HS+
600
600
10.5
10.5
ESC27030WHD Ver. HS+
Ver. WS+
Hor. HS+
Hor. WS+
250
120
290
130
6.0
1.1
5.5
0.8
121
36.3
123
36.2
CC700I36BL
Ver. HS+
600
10.5
CC700I36GY
Ver. HS+
600
10.5
CC700I36WG
Ver. HS+
600
10.5
CC700I36WH
Ver. HS+
600
10.5
CIC700I16BL
Ver. HS+
540
9.5
CIC700I16GY
Ver. HS+
540
9.5
CIC700I16WG
Ver. HS+
540
9.5
CIC700I16WH
Ver. HS+
540
9.5
CIS700I36BL
Ver. HS+
600
9.5
CIS700I36GY
Ver. HS+
600
9.5
CIS700I36WG
Ver. HS+
600
9.5
CIS700I36WH
Ver. HS+
600
9.5
C600M30WHD
C70030BL
C70030GY
C70030WG
C70030WGD
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
VENMAR VENTILATION, INC.
Venmar Jazz
Kitchen Range Hoods – Ducted & Convertible
HDN62330SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ10430SS
Ver. HS+
Ver. WS+
270
180
7.0
3.5
VJ10430WH
Ver. HS+
Ver. WS+
270
180
7.0
3.5
VJ50430SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-74
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
VJ504302SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ60330SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ603302SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ60430SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ604302SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ70330SS
Ver. HS+
Ver. LS+
370
190
8.5
2.5
VJ70430SS
Ver. HS+
Ver. LS+
450
210
8.0
2.0
WATTS
MODEL
OR SERIES
STATIC
*
PRESSURE**
DETAILS
NXMR70FL
NXMR70L
NXMR90
NXMR90L
NXMR110
NXMR110FL
NXMR110L
NXMS50
NXMS50L
NXMS70
NXMS70FL
NXMS70L
NXMS90
NXMS90L
NXMS110
NXMS110FL
NXMS110L
NXSH50
NXSH80
@ 0.25” SP
VJ70524SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ70530SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ70536SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
VJ70636SS
Ver. HS+
Ver. LS+
450
190
8.5
2.5
NXSH80FL
NXSH80L
NXSH110
NXSH110FL
NXSH110L
NXSH130
NXSH130L
NXSS50
NXSS80
NXSS80L
NXSS110
NXSS110L
CFM**
SONES
WATTS
70
70
90
90
110
110
110
50
50
70
70
70
90
90
110
110
110
50
4.5
4.5
3.5
3.5
3.5
3.5
3.5
3.0
3.0
4.5
4.5
4.5
3.5
3.5
3.5
3.5
3.5
0.8
49.4
49.4
55.5
55.5
61.8
61.8
61.8
46.6
46.6
49.4
49.4
49.4
55.5
55.5
61.8
61.8
61.8
30.3
80
65
80
80
110
110
110
120
120
50
80
80
110
110
1.5
42.3
38.1
31.2
31.2
46.6
46.6
46.6
44.9
44.9
40.4
55.2
55.2
88.4
88.4
1.3
1.3
2.0
2.0
2.0
2.0
2.0
0.7
1.0
1.0
2.0
2.0
VENMAR VENTILATION, INC.
RONA
VENTILATION SYSTEMS USA
Kitchen Range Hoods – Ducted & Convertible
Vents
RO300030SS
Hor. HS+
400
12.0
ROQP130SS
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
280
120
280
120
5.0
0.8
5.0
0.8
ROQP130WH
Ver. HS+
Ver. LS+
Hor. HS+
Hor. LS+
280
120
280
120
5.0
0.8
5.0
0.8
Inline Fans (all models)
VENTAMATIC, LTD.
TT100
HS+
LS+
@ 0.20” SP
@ 0.20” SP
30
20
36.0
30.0
TT125
HS+
LS+
@ 0.20” SP
@ 0.20” SP
90
20
41.0
31.0
TT150
HS+
HS+
LS+
LS+
@ 0.20” SP
@ 0.50” SP
@ 0.20” SP
@ 0.50” SP
410
371
380
335
191
189
149
148
TT200
HS+
HS+
LS+
LS+
@ 0.20” SP
@ 0.50” SP
@ 0.20” SP
@ 0.50” SP
430
348
290
155
111
111
70.0
70.0
@ 0.20” SP
@ 0.50” SP
@ 0.20” SP
@ 0.50” SP
990
902
770
633
353
353
236
236
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
150
140
132
106
106
106
Nuvent
Bathroom - Exhaust Fans
NX503
NX703
NXDHVL
NXHVL
NXMR50
NXMR70
50
60
70
70
50
70
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
TT315
Pascals (Pa) = in. wg x 250
4.0
5.5
5.5
5.5
3.0
4.5
50.1
60.8
66.6
66.6
46.6
49.4
VK100
HS+
HS+
LS+
LS+
`
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-75
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
VK125
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
210
189
174
114
114
114
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
280
254
238
113
113
114
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
D90L
VK200
VK250
VK315
VKM125
VKM150
VKM200
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
540
490
458
142
150
147
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
670
618
580
293
297
301
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
770
700
650
271
276
279
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
220
200
187
112
112
112
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
270
235
210
110
110
110
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
480
420
390
196
199
201
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
610
542
480
232
234
235
VKM305
VKP125
VKP150
@ 0.20” SP
@ 0.375” SP
@ 0.5” SP
730
688
659
244
250
254
@ 0.20” SP
@ 0.5” SP
190
163
86.0
86.0
@ 0.20” SP
@ 0.5” SP
@ 0.75” SP
290
256
230
170
170
170
WATTS
90
75
0.7
32.1
29.5
100
84
1.2
@ 0.25” SP
29.2
27.2
110
93
1.5
@ 0.25” SP
30.5
28.5
110
96
1.2
@ 0.25” SP
33.7
31.9
120
105
2.0
@ 0.25” SP
32.1
30.6
E50
50
3.0
36.5
E60
E70
E80
EP50
60
70
80
50
4.0
3.5
4.0
2.5
42.0
27.1
30.8
19.9
80
63
1.3
@ 0.25” SP
31.2
30.9
80
70
1.0
@ 0.25” SP
29.2
28.8
90
76
1.5
@ 0.25” SP
24.5
22.8
90
75
1.1
@ 0.25” SP
24.5
22.7
110
83
2.0
@ 0.25” SP
27.0
25.3
110
93
1.0
@ 0.25” SP
27.3
25.9
D110
D110L
D120
EP80
EP80L
EP90
EP90L
VKM250
SONES
@ 0.25” SP
D100
VK150
CFM**
EP110
EP110L
ZEPHYR
Zephyr
Kitchen Range Hoods – Ducted & Convertible
ES1-E30AB
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
290
130
250
120
5.5
0.8
6.0
1.1
123
36.2
121
36.3
ES1-E30AS
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
290
130
250
120
5.5
0.8
6.0
1.1
123
36.2
121
36.3
ES1-E30AW
Hor. HS+
Hor. LS+
Ver. HS+
Ver. LS+
290
130
250
120
5.5
0.8
6.0
1.1
123
36.2
121
36.3
WINDRIDGE FANS CORP.
Windridge Fans
Bathroom – Exhaust Fans (all models)
D50
50
30
<0.3
@ 0.25” SP
31.7
28.5
0.8
@ 0.25” SP
80
67
27.8
26.1
80
64
0.5
@ 0.25” SP
31.6
28.7
Downdraft Kitchen Exhausters
90
76
1.0
@ 0.25” SP
28.3
26.1
DD1-E30AS
DD1-E36AS
D80
D80L
D90
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
500
500
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
Rev. 09/01/2012
Section 1-76
CERTIFIED VENTILATING FAN PRODUCTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
WATTS
MODEL
OR SERIES
DETAILS
STATIC
*
PRESSURE**
CFM**
SONES
ZHONGSHAN AIRZONE VENTILATED TECHNOLOGY CO. LTD
Win Air
Bathroom – Exhaust Fans (all models)
BPT12-13D
70
64
4.0
50.0
@ 0.25” SP
70
52
1.0
17.0
@ 0.25” SP
1.0
26.2
1.0
34.7
@ 0.25” SP
110
88
110
89
140
122
1.5
45.1
@ 0.25” SP
140
124
1.5
50.0
@ 0.25” SP
110
90
1.2
33.0
@ 0.25” SP
BPT12-13H
BPT14-24A
@ 0.25” SP
BPT18-34A-1
BPT18-54A
BPT18-54AL
BPT18-34ALE-1
ZHONGSHAN GUIDA HARDWARE ELECTRICAL APPLIANCES CO. LTD.
Clever
Bathroom – Exhaust Fans (all models)
ME050
ME070
ME080
ME090
ME100
ME110
ME120
MEHL75
MEL75
MEQ50
MEQ70
MQBF070
MQBF090
MQBF110
MQBF140
MQBF160
MQBFL090
MQBFL110
50
70
80
90
100
110
120
70
70
50
70
70
90
110
140
160
90
110
1.5
3.0
4.0
2.5
3.0
3.5
4.0
4.0
3.0
0.6
1.5
0.3
0.7
1.3
1.5
2.5
0.8
1.3
400
9.0
45.0
60.0
38.0
38.0
40.0
50.0
26.0
28.0
20.0
25.0
30.0
50.0
55.0
25.0
30.0
Kitchen Range Hoods – Ducted & Convertible
SR600
* STATIC PRESSURE {INCHES WATER GAGE (IN. W.G.)}:
** CONVERSIONS:
Pascals (Pa) = in. wg x 250
Direct Discharge Fans (Non-Ducted) @ 0.03 in. wg
Ducted Fans @ 0.10 in. wg; 0.25 in. wg (optional)
Inline Fans @ 0.20 in. wg; two additional (optional) for static pressure
Litres per Second (L/s) = cfm x 0.47
NOTE: CHANGES IN RED INDICATE RECENT REVISIONS TO THE HVI CERTIFIED HOME VENTILATING PRODUCTS DIRECTORY.
WATTS
SECTION II
HVI TESTED/CERTIFIED
STATIC PRODUCTS
("NET FREE AREA")
PRODUCT CATEGORY
Soffit Ventilators
USE OF HVI LABEL
Companies whose products have been certified by HVI shall affix appropriate Labels to those products
HOW ATTIC
VENTILATION
WORKS
The principle of attic ventilation is simple: placing air vents as
near the roof peak as possible to allow warm air to escape —
and intake vents in the soffit or undereaves to allow air to enter
the attic area.
Various forms of exhaust vents are available — powered fans, ridge vents, roof vents,
turbines, and gable end vents. The intake vents that balance the system are cornice vents
and soffit or undereave vents.
The important consideration is that both intake and exhaust vents must be in the system to
promote air movement, and they must be in balance. HVI recommends that 60% of the net
free area of the required ventilation be placed at the undereave location and 40% at the
roof or gable location. HVI guidelines recommend one square foot of ventilator net free
area for each 300 square feet of attic floor space. If no vapor barrier is used, the net free
area of ventilation should be doubled.
To determine your static ventilator needs, first multiply
attic length by attic width to find square feet, then
divide that number by 300 to find required net free
area.
Because most vents are marked in square inches of net free area, multiply the above
number by 144. The total of static vents you install should equal that number in total
square inches. If no vapor barrier is used, multiply the total square inches by 2.
TO CALCULATE
NET FREE AREA
For ease in calculating required static ventilation, request a “HOME
VENTILATION & INDOOR AIR QUALITY” guide from the Home Ventilating
Institute.
Rev. 09/01/2012
CERTIFIED STATIC VENTILATING DEVICES
MODEL
OR SERIES
DESCRIPTION
HVI CERTIFIED NET
FREE AREA (SQ. IN.)*
QUALITY ALUMINUM PRODUCTS, INC.
Quality Aluminum
Soffit Vents
LVP10
Double 5” Lanced V-Panel Soffit
9.6 in²
LVP12
Double 6” Lanced V-Panel Soffit
11.4 in²
CVPT4
Triple 4” Center Lanced V-Panel Soffit
LVPT4
Triple 4” Full Lanced V-Panel Soffit
CVPQ4
Quad 4” Center Lanced V-Panel Soffit
LVPQ4
Quad 4” Full Lanced V-Panel Soffit
10.2 in²
8VTL
8” Vertical Lanced Soffit
10.5 in²
*Per Lineal Feet
4.9 in²
14.8 in²
6.2 in²
MODEL
OR SERIES
DESCRIPTION
Section 2-1
HVI CERTIFIED NET
FREE AREA (SQ. IN)*
SECTION III
HVI TESTED/CERTIFIED
HEAT RECOVERY VENTILATORS
AND
ENERGY RECOVERY VENTILATORS
(HRV/ERV)
(DUCTED HEAT AND ENERGY RECOVERY VENTILATORS)
NOTICE:
HVI Certification of these products is based on CAN/CSA C439, Standard Laboratory Methods of Test for
Rating the Performance of Heat/Energy-Recovery Ventilators, as its test standard for measuring product
performance for certification. Testing for these products has been conducted by an HVI-designated
laboratory.
HVI-Certified product performance ratings for HRV/ERVs are available online at www.hvicertified.org or
from the manufacturer. Companies whose products have been certified by HVI are required to affix
appropriate HVI-Certified Labels to those products. The equipment tested to achieve Certification was
supplied by the manufacturer and is representative of the designated model offered for sale. HVI-Certified
products are subject to regular, random verification testing confirming the performance of production
equipment. ASHRAE Handbook - Fundamentals (SI Edition) was used for conversion factors to convert
cubic feet per minute to liters per second and inches water gage to Pascals.
This Certified data is intended for the ventilation designer, contractor and purchaser of HRV/ERV
equipment. Government and utility programs may also refer to these Certified ratings with confidence.
HVI-Certified equipment can be expected to provide indicated ventilation capacity and energy
performance under specific indoor and outdoor air temperature and humidity conditions.
CONSULT THE EQUIPMENT SUPPLIER FOR PERFORMANCE AT CONDITIONS OTHER THAN
THOSE DESCRIBED.
USE OF HVI LABEL
Companies whose products have been certified by HVI shall affix appropriate Labels to those products.
INTRODUCTION
Heat or energy recovery ventilators are mechanical ventilation systems used to provide substantially
balanced ventilation by providing two separate air paths. It is the combination of an exhaust system and
a supply system in a single packaged solution. The exhaust system removes air from the building and the
supply system adds outdoor air into the building. All products in Section III of the HVI Certified Products
Directory transfer heat (in the case of HRVs) or heat and humidity (in the case of ERVs) reclaiming
energy otherwise wasted in an exhaust air stream and minimizing the cost associated with ventilation.
The HRV/ERV products listed in the HVI Certified Products Directory have been evaluated for airflow
performance as well as their effectiveness of transferring heat or energy.
VENTILATION PERFORMANCE TERMS
External Static Pressure: The total static pressure loss of the exhaust or supply system in the ductwork.
In the case of the exhaust system, the total static pressure differential is the static pressure measured at
point 4 minus the static pressure measured at point 3. The supply system total static pressure differential
is the static pressure measured at point 2 minus the static pressure measured at point 1.
Gross Airflow: The measured airflow rate at points 2 and 3, which may contain cross-leakage between
the supply and exhaust airstreams. These values are used for duct design.
Exhaust Air Transfer (EAT): The percent of exhaust air found in the supply airstream at the specified
external total static pressure. Gross Airflow x (1-(EAT/100)) = Net Airflow.
Net Supply Airflow: The gross supply airflow reduced by measured cross-leakage (EAT). This is the
actual amount of outdoor air delivered by the supply system of the unit and is used for sizing the
equipment for the required ventilation rate.
Very Low Temperature Ventilation Reduction (VLTVR): The percent reduction in airflow rate of the
supply and exhaust systems at the end of the 72-hour test compared with operation under non-frosting
conditions. The final airflow rate is taken as the average of the last 12 hours of the test. This reduction in
airflow results from frost and ice buildup in the exchanger and variation in mechanical ventilation during
defrosting.
Very Low Temperature Airflow Imbalance (VLTAI): The percent of airflow imbalance of the Supply
System Airflow compared to Exhaust System Airflow over the last 12 hours of the 72-hour test.
Latent Recovery/Moisture Transfer (LRMT): Moisture recovered divided by moisture exhausted and
corrected for the effects of cross-leakage. LRMT = 0 indicates that moisture was not transferred (net of
cross-leakage) from the exhaust airstream to the supply airstream. LRMT = 1 would indicate complete
transfer of moisture. LRMT is provided for the Heating Season Performance and the Very Low
Temperature Test as an indication of moisture handling characteristics, and may be used to evaluate the
moisture transfer ability of the equipment in order to assess the humidification or dehumidification
performance of the product at the specified test condition.
ENERGY PERFORMANCE TERMS
Values for energy performance are listed for various outdoor air temperature and humidity conditions at a
specific net airflow selected by the manufacturer. It is important to recognize that for comparison of
equipment, only values at equivalent outdoor air conditions and net airflow should be used.
Heating Season Performance: This is a mandatory test for HVI Certification at 0°C (+32°F) and 75%
relative humidity for the outdoor air and at 22°C (71.6°F) and 40% relative humidity for the indoor air.
This test represents the typical steady-state energy performance of the HRV/ERV. Performance is more
comparable using this Heating Season Performance data due to the absence of frost formation.
Very Low Temperature Test: This is an optional test for HVI Certification. The Very Low Temperature
Test is typically conducted at -25°C (-13°F) and at 22°C (71.6°F) and 40% relative humidity for the indoor
air, although the manufacturer may chose to conduct this test at any outdoor temperature below freezing.
The test duration is 72 hours. The Net Supply Airflow and all other energy performance values are
calculated by using the averages of the last 12 hours of the test.
Cooling Season Performance: This is an optional test for HVI Certification. Outdoor air conditions are
35°C (95°F) at 50% relative humidity, indoor air conditions are 24°C (75°F) at 50% relative humidity.
Total Recovery Efficiency (see below) is reported in place of Sensible Recovery Efficiency (see below) as
the latter value is less relevant for cooling load applications.
Watts: The average power consumed during the specific test. DO NOT USE THIS VALUE TO
DETERMINE REQUIRED ELECTRIC SERVICE. REFER TO THE ELECTRICAL RATING
INFORMATION SUPPLIED BY THE MANUFACTURER.
Apparent Sensible Effectiveness (ASEF): The measured temperature rise of the supply airstream
divided by the difference between the outdoor temperature (point 1) and entering exhaust system air
temperature (point 3), then multiplied by the ratio of mass flow rate of the supply airflow divided by the
mass flow rate of the lower of the supply or exhaust system airflows. Apparent Sensible Effectiveness is
useful to predict final delivered air temperature at a given flow rate and should be used for energy
modeling when wattage for air movement is separately accounted for in the energy model.
Sensible Recovery Efficiency (SRE): The net sensible energy recovered by the supply airstream as
adjusted by electric consumption, case heat loss or heat gain, air leakage, airflow mass imbalance
between the two airstreams and the energy used for defrost (when running the Very Low Temperature
Test), as a percent of the potential sensible energy that could be recovered plus the exhaust fan energy.
This value is used to predict and compare Heating Season Performance of the HRV/ERV unit.
Total Recovery Efficiency (TRE): The net total energy (sensible plus latent, also called enthalpy)
recovered by the supply airstream adjusted by electric consumption, case heat loss or heat gain, air
leakage and airflow mass imbalance between the two airstreams, as a percent of the potential total
energy that could be recovered plus the exhaust fan energy. This value is used to predict and compare
Cooling Season Performance for the HRV/ERV unit.
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-1
AEROMATIC
Model: 7230  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.06 @ 100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: ---% Supply ---% Exhaust  Low Temp. Imbalance Factor: -
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
48
103
51
107
57
cfm
122
50
0.2
44
94
46
98
52
111
75
0.3
40
85
42
89
48
101
100
0.4
35
74
37
78
41
87
125
0.5
29
61
30
64
36
76
150
0.6
22
48
23
59
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
38
58
42
57
48
54
NET
AIR FLOW
L/S
CFM
22
46
26
54
33
71
°F
+32
+32
+32
APPARENT
SENSIBLE
EFFECTIVENESS
68
66
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.00
AEROMATIC
Model: 7260  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 32% Supply 18% Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
87
55
117
50
0.2
35
75
37
78
51
108
75
0.3
32
67
33
69
46
97
100
0.4
28
60
29
62
41
87
125
0.5
25
53
26
55
36
77
150
0.6
23
48
23
50
32
69
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
54
31
66
39
82
-13
22
47
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
98
64
110
63
124
61
97
49
APPARENT
SENSIBLE
EFFECTIVENESS
79
77
76
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
0.01
80
0.09
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-2
AEROMATIC
Model: 7290  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 1.8
Exhaust Air Transfer Ratio: 0.03@ 100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15.1% Supply 25.1% Exhaust  Low Temp. Imbalance Factor: 1.07
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
66
141
68
145
69
147
50
0.2
60
128
62
133
62
133
75
0.3
56
120
58
124
56
120
100
0.4
51
109
53
113
51
108
125
0.5
48
103
50
106
45
95
150
0.6
44
94
46
97
38
81
175
0.7
40
85
41
88
29
63
200
0.8
34
73
36
76
17
37
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
41
87
51
109
-25
-13
33
+35
+35
+95
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
128
65
152
63
172
62
70
136
62
APPARENT
SENSIBLE
EFFECTIVENESS
80
77
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.02
82
TOTAL RECOVERY EFFICIENCY
Not tested
0.06
AEROMATIC
Model: 7292v  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 1.8
Exhaust Air Transfer Ratio: 0.02@ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18% Supply 25% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
205
99
209
102
217
50
0.2
89
188
91
192
94
198
75
0.3
82
174
84
178
86
183
100
0.4
77
162
78
166
89
169
125
0.5
71
150
73
154
74
156
150
0.6
65
138
67
141
68
144
175
0.7
59
125
60
128
62
132
200
0.8
53
112
54
114
56
119
225
0.9
46
98
47
101
49
104
250
1.0
41
86
42
88
41
88
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
32
67
46
98
54
115
-13
33
70
POWER
CONSUMED
WATTS
86
104
118
SENSIBLE
RECOVERY
EFFICIENCY
69
66
65
APPARENT
SENSIBLE
EFFECTIVENESS
81
77
75
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
99
64
85
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-3
AEROMATIC
Model: S75D  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 0.6
Exhaust Air Transfer Ratio: 0.03@ 100 Pa/0.4 in. wg 0.23 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16% Supply 25% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
51
107
52
110
55
cfm
116
50
0.2
45
96
46
98
50
106
75
0.3
40
84
41
86
44
94
100
0.4
34
72
35
74
38
81
125
0.5
29
60
29
62
32
68
150
0.6
23
49
24
50
26
55
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
20
42
31
65
42
90
-13
32
POWER
CONSUMED
WATTS
28
52
66
SENSIBLE
RECOVERY
EFFICIENCY
66
61
60
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.04
0.02
0.02
54
57
74
-0.02
67
AEROMATIC
Model: S180D  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 1.8
Exhaust Air Transfer Ratio: 0.03@ 100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17% Supply 19% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
111
236
111
237
117
cfm
249
50
0.2
102
216
102
217
106
225
75
0.3
93
199
94
199
96
205
100
0.4
84
179
84
179
90
191
125
0.5
77
163
77
164
82
175
150
0.6
67
142
67
142
77
163
175
0.7
60
127
60
127
69
146
200
0.8
52
111
53
112
58
122
225
0.9
46
99
47
99
50
107
250
1.0
37
79
37
80
40
86
275
1.1
32
68
32
68
36
76
300
1.2
26
55
26
55
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
32
32
NET
AIR FLOW
L/S
CFM
32
67
47
99
-13
33
70
POWER
CONSUMED
WATTS
70
82
SENSIBLE
RECOVERY
EFFICIENCY
67
65
APPARENT
SENSIBLE
EFFECTIVENESS
77
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.01
82
60
79
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-4
AIRFLOW
Model: AIR 130-R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: .92% Supply n/a Exhaust  Low Temp. Imbalance Factor: .92
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
74
156
70
160
67
153
50
0.2
69
146
71
150
69
146
75
0.3
63
134
65
137
60
128
100
0.4
59
124
61
127
59
122
125
0.5
54
115
56
117
54
114
150
0.6
49
104
51
106
49
102
175
0.7
45
95
47
98
45
94
200
0.8
40
85
41
87
40
77
225
0.9
33
69
34
71
33
68
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
66
40
85
55
117
-13
36
POWER
CONSUMED
WATTS
74
86
140
SENSIBLE
RECOVERY
EFFICIENCY
61
61
56
APPARENT
SENSIBLE
EFFECTIVENESS
74
73
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
96
63
78
0.04
76
AIRFLOW
Model: AIR 150-D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 0% Exhaust  Low Temp. Imbalance Factor: n/a
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
83
177
83
177
88
187
50
0.2
77
164
77
164
84
179
75
0.3
73
156
73
156
85
181
100
0.4
67
143
67
143
83
176
125
0.5
58
123
58
123
81
171
150
0.6
47
100
47
100
74
158
175
0.7
18
38
18
38
70
149
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
32
32
32
NET
AIR FLOW
L/S
CFM
32
67
44
94
56
118
-25
-13
32
35
95
31
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
66
95
64
110
60
68
82
66
74
60
APPARENT
SENSIBLE
EFFECTIVENESS
76
72
68
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.20
-0.02
78
TOTAL RECOVERY EFFICIENCY
20
0.08
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-5
AIRFLOW
Model: AIR 200-D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 1% Supply 2% Exhaust  Low Temp. Imbalance Factor: 0.967
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
101
214
102
216
97
206
50
0.2
97
206
98
208
93
197
75
0.3
91
193
93
197
88
186
100
0.4
87
184
88
186
82
174
125
0.5
80
170
81
172
75
159
150
0.6
73
155
74
157
67
142
175
0.7
65
137
65
138
54
114
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
68
144
63
133
56
119
-13
-13
60
55
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
114
59
109
58
100
60
127
117
100
59
60
APPARENT
SENSIBLE
EFFECTIVENESS
66
66
67
LATENT
RECOVERY/MOISTURE
TRANSFER
0
0
0
69
0
AIRFLOW
Model: 120 AIR-R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.0% Supply 15.0% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
Pa
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
67
142
68
144
72
154
50
0.2
64
137
65
138
69
147
75
0.3
62
131
62
133
66
141
100
0.4
60
128
61
129
64
135
125
0.5
58
123
58
124
60
128
150
0.6
54
115
55
116
58
123
175
0.7
53
113
54
114
55
116
200
0.8
49
105
50
106
51
109
225
0.9
48
102
48
103
48
102
250
1.0
45
96
46
97
45
95
275
1.1
42
90
43
91
41
87
300
1.2
39
84
40
85
33
71
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
33
70
42
89
56
130
-13
32
67
POWER
CONSUMED
WATTS
76
94
156
SENSIBLE
RECOVERY
EFFICIENCY
59
57
52
APPARENT
SENSIBLE
EFFECTIVENESS
68
67
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.03
0.03
109
56
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-6
AIRFLOW
Model: 200 AIR-R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
109
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
AIRFLOW
Model: 155 AIR-R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
68
144
70
149
80
cfm
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-7
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 150 ERVD  Options Installed: None
Electrical Requirements: Volts: 115 Amps: 1.0
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 0.9% Supply 6.7% Exhaust  Low Temp. Imbalance Factor: 1.01
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
142
69
147
74
156
50
0.2
65
139
68
143
70
147
75
0.3
60
127
62
131
62
132
100
0.4
57
121
59
125
58
123
125
0.5
50
106
51
109
53
111
150
0.6
41
87
42
90
44
94
175
0.7
32
67
33
69
40
84
200
0.8
25
53
26
54
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
°F
HEATING
0
+32
0
+32
0
+32
COOLING
NET
AIR FLOW
L/S
CFM
31
66
33
71
54
114
LATENT
RECOVERY/MOISTURE
TRANSFER
0.57
0.56
0.48
POWER
CONSUMED
WATTS
69
70
106
SENSIBLE
RECOVERY
EFFICIENCY
69
70
66
APPARENT
SENSIBLE
EFFECTIVENESS
80
80
76
57
75
TOTAL RECOVERY EFFICIENCY
49
-25
-13
36
76
77
+35
+95
31
65
68
0.54
AIRIA BRANDS
INC. (LIFEBREATH®)
AIRFLOW
Model: 155 ECM  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 6% Supply 8% Exhaust  Low Temp. Imbalance Factor: 0.92
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
77
164
78
166
80
170
50
0.2
74
157
75
159
76
160
75
0.3
69
147
70
149
71
150
100
0.4
69
146
70
148
64
136
125
0.5
66
140
67
142
56
119
150
0.6
65
138
66
140
48
102
175
0.7
62
131
63
133
43
91
200
0.8
57
121
58
123
40
84
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
°F
HEATING
0
+32
0
+32
0
+32
COOLING
NET
AIR FLOW
L/S
CFM
31
66
46
98
55
118
POWER
CONSUMED
WATTS
33
74
67
SENSIBLE
RECOVERY
EFFICIENCY
66
63
64
APPARENT
SENSIBLE
EFFECTIVENESS
72
70
69
67
79
TOTAL RECOVERY EFFICIENCY
18
-25
-13
31
66
36
+35
+95
31
66
33
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-8
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 195DCS  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 4.3% Exhaust  Low Temp. Imbalance Factor: .93
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
101
216
108
229
103
219
92
195
97
207
96
205
85
181
91
193
90
192
74
158
79
168
84
179
68
144
72
153
77
164
59
125
63
133
69
146
50
107
53
114
61
130
34
72
36
76
51
109
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
-25
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
35
73
46
98
54
114
73
155
-13
53
POWER
CONSUMED
WATTS
74
88
98
123
SENSIBLE
RECOVERY
EFFICIENCY
82
78
78
75
APPARENT
SENSIBLE
EFFECTIVENESS
92
88
86
82
LATENT
RECOVERY/MOISTURE
TRANSFER
0.10
0.07
0.05
0.02
97
72
88
0.01
112
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 195ECM  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.7
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 5% Exhaust  Low Temp. Imbalance Factor: 0.87
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
90
191
94
201
81
173
86
184
91
193
79
169
83
177
87
186
76
161
80
169
83
178
74
156
75
159
79
167
69
146
71
152
75
159
64
135
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
55
117
-13
55
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
81
67
78
74
69
APPARENT
SENSIBLE
EFFECTIVENESS
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.04
0.04
87
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-9
RIA BRANDS INC. (LIFEBREATH®)
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 300DCS  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.9
Exhaust Air Transfer Ratio: 0.06 @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 4% Supply 3% Exhaust  Low Temp. Imbalance Factor: 0.90
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
02
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
110
232
117
247
123
261
100
212
107
226
117
248
96
202
102
215
112
238
86
183
92
195
105
222
77
163
82
174
95
202
68
144
72
153
88
187
58
123
62
131
79
166
43
92
46
98
68
144
36
76
38
81
55
117
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
66
140
96
203
-13
62
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
118
79
132
77
207
74
132
125
70
APPARENT
SENSIBLE
EFFECTIVENESS
90
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.14
0.05
0.04
88
0.04
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 95MAX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
36
76
40
84
49
cfm
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
98
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
61
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-10
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 150 ERV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply - NA Exhaust - NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
71
151
74
157
73
154
50
0.2
67
141
69
146
69
147
75
0.3
62
132
65
137
67
142
100
0.4
59
124
61
129
61
130
125
0.5
50
107
52
111
54
116
150
0.6
46
98
48
102
48
101
175
0.7
38
81
40
84
41
87
200
0.8
28
60
30
63
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
-25
-13
+35
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
69
94
67
108
65
NET
AIR FLOW
L/S
CFM
30
63
45
96
55
117
30
65
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
.50
.42
.38
TOTAL RECOVERY EFFICIENCY
47
68
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 155 MAX Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
68
144
70
149
80
cfm
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-11
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 155 MAXRX Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 200 ERV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
65
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
64
98
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
TRANSFER
EFFECTIVENESS
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-12
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 200 MAX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
°F
NET
AIR FLOW
L/S
CFM
0
0
0
+32
+32
+32
31
45
55
66
96
117
81
99
113
64
63
61
SENSIBLE
EFFECTIVENESS
74
71
69
-25
-13
51
109
119
62
73
HEATING
APPARENT
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
0.01
AIRIA BRANDS INC. (LIFEBREATH®)
Model: 200 MAXRX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
°F
NET
AIR FLOW
L/S
CFM
0
0
0
+32
+32
+32
31
45
55
66
96
117
81
99
113
64
63
61
SENSIBLE
EFFECTIVENESS
74
71
69
-25
-13
51
109
119
62
73
APPARENT
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-13
AIRIA BRANDS INC. (LIFEBREATH®)
Model: MAXTOP  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 6% Supply 13% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
93
196
94
199
93
197
50
0.2
89
188
90
190
88
186
75
0.3
84
178
85
181
83
176
100
0.4
78
165
79
167
77
163
125
0.5
70
149
71
151
73
154
150
0.6
62
131
63
133
63
134
175
0.7
51
109
52
110
51
108
200
0.8
37
79
38
80
41
86
225
0.9
23
48
23
49
22
47
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
69
94
67
105
64
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
45
96
55
117
-25
-13
31
67
84
+35
+95
30
64
72
70
APPARENT
SENSIBLE
EFFECTIVENESS
80
75
72
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
83
TOTAL RECOVERY EFFICIENCY
22
0.03
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC5-TPD  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3% Supply 7% Exhaust  Low Temp. Imbalance Factor: 0.92
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
74
156
70
160
67
153
50
0.2
69
146
71
150
69
146
75
0.3
63
134
65
137
60
128
100
0.4
59
124
61
127
60
122
125
0.5
54
115
56
117
54
114
150
0.6
49
104
51
106
49
102
175
0.7
45
95
47
98
45
94
200
0.8
40
85
41
87
40
77
225
0.9
33
69
34
71
33
68
250
1.0
27
58
28
60
28
60
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
85
55
117
-13
36
76
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
61
86
61
140
56
96
63
APPARENT
SENSIBLE
EFFECTIVENESS
74
73
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-14
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC5-TPF  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.78
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
82
174
83
176
82
174
50
0.2
77
165
78
166
77
162
75
0.3
73
154
73
156
71
150
100
0.4
67
143
68
145
65
138
125
0.5
62
132
63
133
60
126
150
0.6
56
120
57
121
54
114
175
0.7
51
107
51
108
48
102
200
0.8
45
95
45
96
43
90
225
0.9
39
83
39
83
37
78
250
1.0
33
71
34
71
31
66
275
1.1
28
60
28
60
26
54
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
30
64
46
97
55
117
-13
33
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
60
66
76
65
92
63
69
61
56
APPARENT
SENSIBLE
EFFECTIVENESS
75
73
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
-0.03
-0.02
79
0.00
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC10  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 0% Exhaust  Low Temp. Imbalance Factor: n/a
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
83
177
83
177
88
187
50
0.2
77
164
77
164
84
179
75
0.3
73
156
73
156
85
181
100
0.4
67
143
67
143
83
176
125
0.5
58
123
58
123
81
171
150
0.6
47
100
47
100
74
158
175
0.7
18
38
18
38
70
149
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
78
66
95
64
110
60
°F
32
32
32
NET
AIR FLOW
L/S
CFM
32
67
44
94
56
118
-25
-13
32
68
82
35
95
31
66
74
60
APPARENT
SENSIBLE
EFFECTIVENESS
76
72
68
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.20
-0.02
78
TOTAL RECOVERY EFFICIENCY
20
0.08
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-15
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC20  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 1% Supply 2% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
101
214
102
216
97
206
50
0.2
97
206
98
208
93
197
75
0.3
91
193
93
197
88
186
100
0.4
87
184
88
186
82
174
125
0.5
80
170
81
172
75
159
150
0.6
73
155
74
157
67
142
175
0.7
65
137
65
138
54
114
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
68
144
63
133
56
119
-13
-13
60
55
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
114
59
109
58
100
60
127
117
100
59
60
APPARENT
SENSIBLE
EFFECTIVENESS
66
66
67
LATENT
RECOVERY/MOISTURE
TRANSFER
0
0
0
69
0
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC95  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
36
76
40
84
49
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
98
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
61
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-16
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC120D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.6% Supply 14.9% Exhaust  Low Temp. Imbalance Factor: 6.5%
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
142
68
144
72
154
50
0.2
64
137
65
138
69
147
75
0.3
62
131
62
133
66
141
100
0.4
60
128
61
129
64
135
125
0.5
58
123
58
124
60
128
150
0.6
54
115
55
116
58
123
175
0.7
53
113
54
114
55
116
200
0.8
49
105
50
106
51
109
225
0.9
48
102
48
103
48
102
250
1.0
45
96
46
97
45
95
275
1.1
42
90
43
91
41
87
300
1.2
39
84
40
85
33
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
33
70
42
89
56
120
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
76
59
94
57
156
52
67
109
56
APPARENT
SENSIBLE
EFFECTIVENESS
68
67
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.03
0.03
72
0.01
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC155 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-17
AIRIA BRANDS INC. (LIFEBREATH®)
Model: RNC 200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
cfm
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
109
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
AIR KING
Model: AKERV150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply - NA Exhaust - NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
71
151
74
157
73
cfm
154
50
0.2
67
141
69
146
69
147
75
0.3
62
132
65
137
67
142
100
0.4
59
124
61
129
61
130
125
0.5
50
107
52
111
54
116
150
0.6
46
98
48
102
48
101
175
0.7
38
81
40
84
41
87
200
0.8
28
60
30
63
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
-25
-13
+35
+95
NET
AIR FLOW
L/S
CFM
30
63
45
96
55
117
30
65
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
69
94
67
108
65
68
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
73
TOTAL RECOVERY EFFICIENCY
47
LATENT
RECOVERY/MOISTURE
TRANSFER
.50
.42
.38
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-18
AIR KING
Model: AKERV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
65
117
64
98
LATENT
APPARENT
RECOVERY/MOISTURE
SENSIBLE
EFFECTIVENESS
TRANSFER
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
AIR KING
Model: AKHRV149  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3% Supply 7% Exhaust  Low Temp. Imbalance Factor: 0.92
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
74
156
70
160
67
153
50
0.2
69
146
71
150
69
146
75
0.3
63
134
65
137
60
128
100
0.4
59
124
61
127
60
122
125
0.5
54
115
56
117
54
114
150
0.6
49
104
51
106
49
102
175
0.7
45
95
47
98
45
94
200
0.8
40
85
41
87
40
77
225
0.9
33
69
34
71
33
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
85
55
117
-13
36
76
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
61
86
61
140
56
96
63
APPARENT
SENSIBLE
EFFECTIVENESS
74
73
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-19
AIR KING
Model: AKHRV155 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
AIR KING
Model: AKHRV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
:
HEATING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
°F
NET
AIR FLOW
L/S
CFM
0
0
0
+32
+32
+32
31
45
55
66
96
117
81
99
113
64
63
61
SENSIBLE
EFFECTIVENESS
74
71
69
-25
-13
51
109
119
62
73
APPARENT
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-20
AIRTECH-107
Model: H-140  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.9
Exhaust Air Transfer Ratio: 0.001 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
57
122
58
123
56
cfm
120
50
0.2
52
110
52
111
49
105
75
0.3
46
99
47
100
44
93
100
0.4
41
87
41
87
36
76
125
0.5
34
73
34
73
31
65
150
0.6
26
54
26
55
21
44
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
52
71
68
67
90
65
NET
AIR FLOW
L/S
CFM
31
66
41
88
48
103
°F
+32
+32
+32
-13
+35
+35
+95
+95
30
64
52
APPARENT
SENSIBLE
EFFECTIVENESS
80
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.60
0.55
0.53
TOTAL RECOVERY EFFICIENCY
55
ALPINE PURE
Model: APERV200H  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
65
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
64
98
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-21
ALPINE PURE
Model: APHRV150V Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3% Supply 7% Exhaust  Low Temp. Imbalance Factor: 0.92
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
74
156
70
160
67
153
50
0.2
69
146
71
150
69
146
75
0.3
63
134
65
137
60
128
100
0.4
59
124
61
127
60
122
125
0.5
54
115
56
117
54
114
150
0.6
49
104
51
106
49
102
175
0.7
45
95
47
98
45
94
200
0.8
40
85
41
87
40
77
225
0.9
33
69
34
71
33
68
250
1.0
27
58
28
60
28
60
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
85
55
117
-13
36
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
61
86
61
140
56
76
96
63
APPARENT
SENSIBLE
EFFECTIVENESS
74
73
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
0.04
ALPINE PURE
Model: APHRV200H  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
°F
NET
AIR FLOW
L/S
CFM
0
0
0
+32
+32
+32
31
45
55
66
96
117
81
99
113
64
63
61
SENSIBLE
EFFECTIVENESS
74
71
69
-25
-13
51
109
119
62
73
APPARENT
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-22
ALPINE PURE
Model: APHRV300H  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.9
Exhaust Air Transfer Ratio: 0.06 @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 4% Supply 3% Exhaust  Low Temp. Imbalance Factor: 0.90
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
02
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
110
232
117
247
123
261
100
212
107
226
117
248
96
202
102
215
112
238
86
183
92
195
105
222
77
163
82
174
95
202
68
144
72
153
88
187
58
123
62
131
79
166
43
92
46
98
68
144
36
76
38
81
55
117
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
66
140
96
203
-25
-13
62
+35
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
118
79
132
77
207
74
132
125
APPARENT
SENSIBLE
EFFECTIVENESS
90
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.14
0.05
0.04
88
0.04
70
TOTAL RECOVERY EFFICIENCY
Not tested
AMANA BRAND INDOOR AIR QUALITY PRODUCTS
Model: HRV150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
73
56
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-23
AMANA BRAND INDOOR AIR QUALITY PRODUCTS
Model: HRV150D  Options Installed: Damper
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 14% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
78
167
80
169
86
182
50
0.2
74
158
75
160
79
168
75
0.3
71
150
72
152
75
160
100
0.4
67
142
68
144
68
145
125
0.5
65
137
66
140
63
135
150
0.6
58
124
59
126
58
123
175
0.7
52
110
53
112
52
110
200
0.8
47
100
48
101
46
98
225
0.9
42
89
43
91
40
84
250
1.0
36
76
36
77
34
71
275
1.1
28
60
28
60
27
58
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
49
104
76
161
-13
32
POWER
CONSUMED
WATTS
72
102
148
SENSIBLE
RECOVERY
EFFICIENCY
59
61
58
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
-0.01
96
61
77
0.02
68
AMANA BRAND INDOOR AIR QUALITY PRODUCTS
Model: HRV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
325
1.3
350
1.4
375
1.5
NET SUPPLY
AIR FLOW
L/s
cfm
114
243
109
230
103
218
95
201
86
182
78
166
71
151
65
137
59
125
53
112
46
98
42
88
37
78
31
66
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
116
246
120
254
110
233
115
244
104
221
106
225
96
204
101
215
87
185
94
199
79
168
87
184
72
154
79
168
66
139
71
151
60
127
64
136
53
113
56
118
47
99
51
108
42
90
44
93
37
79
39
83
32
67
35
75
26
56
30
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
129
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
154
59
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-24
AMANA BRAND INDOOR AIR QUALITY PRODUCTS
Model: HRV200D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
325
1.3
350
1.4
375
1.5
NET SUPPLY
AIR FLOW
L/s
cfm
114
243
109
230
103
218
95
201
86
182
78
166
71
151
65
137
59
125
53
112
46
98
42
88
37
78
31
66
26
55
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
116
246
120
254
110
233
115
244
104
221
106
225
96
204
101
215
87
185
94
199
79
168
87
184
72
154
79
168
66
139
71
151
60
127
64
136
53
113
56
118
47
99
51
108
42
90
44
93
37
79
39
83
32
67
35
75
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
126
141
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
64
AMANA BRAND INDOOR AIR QUALITY PRODUCTS
Model: HRV300D  Options Installed: None
Electrical Requirements: Volts: 115 Amps: 2.7
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
126
268
131
277
139
294
50
0.2
124
262
127
270
132
279
75
0.3
116
246
119
253
126
266
100
0.4
109
231
112
238
117
247
125
0.5
103
219
107
226
111
236
150
0.6
96
204
100
211
101
215
175
0.7
93
196
95
202
101
213
200
0.8
89
188
92
194
94
200
250
1.0
77
163
79
168
82
174
300
1.2
69
147
71
151
71
151
350
1.4
56
118
57
121
58
123
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
55
117
74
157
POWER
CONSUMED
WATTS
126
212
262
SENSIBLE
RECOVERY
EFFICIENCY
76
78
78
-25
-25
-13
-13
57
55
121
117
224
220
72
72
+35
+35
+95
+95
54
74
115
159
206
260
APPARENT
SENSIBLE
EFFECTIVENESS
91
92
91
LATENT
RECOVERY/MOISTURE
TRANSFER
.02
.01
-.09
91
-TOTAL RECOVERY EFFICIENCY
18
17
.09
--
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-25
AMERICAN ALDES VENTILATION CORPORATION
Model: LT15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 0% Exhaust  Low Temp. Imbalance Factor: n/a
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
83
177
83
177
88
187
50
0.2
77
164
77
164
84
179
75
0.3
73
156
73
156
85
181
100
0.4
67
143
67
143
83
176
125
0.5
58
123
58
123
81
171
150
0.6
47
100
47
100
74
158
175
0.7
18
38
18
38
70
149
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
32
32
32
NET
AIR FLOW
L/S
CFM
32
67
44
94
56
118
-25
-13
32
35
95
31
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
66
95
64
110
60
68
82
66
74
60
APPARENT
SENSIBLE
EFFECTIVENESS
76
72
68
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.20
-0.02
78
TOTAL RECOVERY EFFICIENCY
20
0.08
AMERICAN ALDES VENTILATION CORPORATION
Model: LT20  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 1% Supply 2% Exhaust  Low Temp. Imbalance Factor: 0.967
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
101
214
102
216
97
206
50
0.2
97
206
98
208
93
197
75
0.3
91
193
93
197
88
186
100
0.4
87
184
88
186
82
174
125
0.5
80
170
81
172
75
159
150
0.6
73
155
74
157
67
142
175
0.7
65
137
65
138
54
114
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
68
144
63
133
56
119
-13
-13
60
55
127
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
114
59
109
58
100
60
100
59
60
APPARENT
SENSIBLE
EFFECTIVENESS
66
66
67
LATENT
RECOVERY/MOISTURE
TRANSFER
0
0
0
69
0
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-26
AMERICAN ALDES VENTILATION CORPORATION
Model: 95 SRD  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
36
76
40
84
49
cfm
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
98
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
61
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
AMERICAN ALDES VENTILATION CORPORATION
Model: 120 SRD  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.6% Supply 14.9% Exhaust  Low Temp. Imbalance Factor: .065
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
142
68
144
72
154
50
0.2
64
137
65
138
69
147
75
0.3
62
131
62
133
66
141
100
0.4
60
128
61
129
64
135
125
0.5
58
123
58
124
60
128
150
0.6
54
115
55
116
58
123
175
0.7
53
113
54
114
55
116
200
0.8
49
105
50
106
51
109
225
0.9
48
102
48
103
48
102
250
1.0
45
96
46
97
45
95
275
1.1
42
90
43
91
41
87
300
1.2
39
84
40
85
33
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
33
70
42
89
56
120
-13
32
67
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
76
59
94
57
156
52
109
56
APPARENT
SENSIBLE
EFFECTIVENESS
68
67
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.03
0.03
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-27
AMERICAN ALDES VENTILATION CORPORATION
Model: 155 SRD Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
AMERICAN ALDES VENTILATION CORPORATION
Model: 200S  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
65
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
64
98
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-28
AMERICAN ALDES VENTILATION CORPORATION
Model: 200 SRD  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
62
AMERICAN ALDES VENTILATION CORPORATION
Model: 300DDD  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.9
Exhaust Air Transfer Ratio: 0.06 @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 4% Supply 3% Exhaust  Low Temp. Imbalance Factor: 0.90
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
02
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
110
232
117
247
123
261
100
212
107
226
117
248
96
202
102
215
112
238
86
183
92
195
105
222
77
163
82
174
95
202
68
144
72
153
88
187
58
123
62
131
79
166
43
92
46
98
68
144
36
76
38
81
55
117
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
66
140
96
203
-25
-13
62
+35
+95
132
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
118
79
132
77
207
74
125
70
APPARENT
SENSIBLE
EFFECTIVENESS
90
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.14
0.05
0.04
88
0.04
TOTAL RECOVERY EFFICIENCY
Not tested
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-29
AMERICAN STANDARD
Model Number: AERVR100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
77
165
79
168
79
168
50
0.2
72
153
73
156
73
156
75
0.3
64
137
66
140
66
140
100
0.4
59
126
61
129
61
129
125
0.5
49
104
50
106
50
106
150
0.6
37
79
38
81
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
61
130
COOLING
+95
61
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
102
71
130
102
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.53
TOTAL RECOVERY EFFICIENCY
48
AMERICAN STANDARD
Model Number: AERVR200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa /0.4 in. wg 0.03 @ 50 Pa/0.2 in. wg
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
213
109
232
50
0.2
90
192
93
199
104
221
75
0.3
88
186
90
192
101
216
100
0.4
83
176
85
181
96
204
125
0.5
79
168
81
173
88
187
150
0.6
70
149
72
154
76
162
175
0.7
57
122
59
126
68
145
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
85
181
COOLING
+95
85
+35
180
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
157
78
155
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
85
0.62
TOTAL RECOVERY EFFICIENCY
52
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-30
AMERICAN STANDARD
Model Number: AERVR300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg --- @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
100
0.4
147
311
150
317
143
303
125
0.5
139
295
142
301
133
283
150
0.6
131
277
133
282
125
265
175
0.7
121
256
123
261
108
230
200
0.8
101
215
103
219
94
198
225
0.9
90
191
92
195
74
156
250
1.0
80
170
82
174
47
99
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
139
297
COOLING
+95
138
+35
POWER
CONSUMED
WATTS
315
294
SENSIBLE
RECOVERY
EFFICIENCY
67
313
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
74
0.54
TOTAL RECOVERY EFFICIENCY
46
BROAN – NUTONE LLC
Model: ERV90HCS  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 34.1% Supply 33.0% Exhaust  Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
55
116
56
119
55
116
50
0.2
53
113
54
115
53
112
75
0.3
51
108
52
111
51
108
100
0.4
50
105
51
108
50
105
125
0.5
48
102
50
105
47
100
150
0.6
46
97
47
99
45
95
175
0.7
44
94
45
96
43
92
200
0.8
42
89
43
92
41
87
225
0.9
40
85
41
87
40
85
250
1.0
38
80
39
83
37
78
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
42
68
46
68
70
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
21
45
27
58
41
87
-25
-13
22
47
58
+35
+95
21
44
42
55
APPARENT
SENSIBLE
EFFECTIVENESS
79
76
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.63
0.58
0.48
78
TOTAL RECOVERY EFFICIENCY
52
0.60
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-31
BROAN – NUTONE LLC
Model: ERV90HCT Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 34.1% Supply 33.0% Exhaust  Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
55
116
56
119
55
116
50
0.2
53
113
54
115
53
112
75
0.3
51
108
52
111
51
108
100
0.4
50
105
51
108
50
105
125
0.5
48
102
50
105
47
100
150
0.6
46
97
47
99
45
95
175
0.7
44
94
45
96
43
92
200
0.8
42
89
43
92
41
87
225
0.9
40
85
41
87
40
85
250
1.0
38
80
39
83
37
78
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
42
68
46
68
70
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
21
45
27
58
41
87
-25
-13
22
47
58
+35
+95
21
44
42
APPARENT
SENSIBLE
EFFECTIVENESS
79
76
71
55
LATENT
RECOVERY/MOISTURE
TRANSFER
0.63
0.58
0.48
78
TOTAL RECOVERY EFFICIENCY
52
0.60
BROAN - NUTONE LLC
Model: ERV 100 HC  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.07 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 22.6% Supply 25.2% Exhaust  Low Temp. Imbalance Factor: 1.08
EXT. STATIC
PRESSURE
Pa
in wg
25
50
75
100
125
150
175
0.1
0.2
0.3
0.4
0.5
0.6
0.7
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
76
70
64
58
50
39
31
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
162
149
136
123
106
83
65
81
74
68
61
53
41
32
171
157
144
130
113
88
69
86
79
71
61
51
42
22
183
169
151
130
109
89
47
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
68
82
67
124
64
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
61
131
-25
-13
37
78
100
+35
+95
30
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
80
77
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.53
0.42
0.37
78
TOTAL RECOVERY EFFICIENCY
49
0.60
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-32
BROAN - NUTONE LLC
Model: ERV 200 HC  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: ---- @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.84
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
109
231
116
245
128
271
50
0.2
108
228
114
241
123
260
75
0.3
101
214
107
227
118
249
100
0.4
95
201
101
213
110
233
125
0.5
86
182
91
193
102
217
150
0.6
79
167
84
177
92
195
175
0.7
62
132
66
140
81
172
200
0.8
40
85
42
90
55
116
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
93
69
130
64
193
60
NET
AIR FLOW
L/S
CFM
52
110
74
157
96
203
°F
+32
+32
+32
-15
5
52
110
122
+35
+95
50
106
89
55
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.45
0.38
0.30
76
TOTAL RECOVERY EFFICIENCY
41
0.26
BROAN – NUTONE LLC
Model: Guardian Plus HR 2.6  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust  Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
54
114
56
119
52
110
53
112
55
117
50
106
50
106
52
111
49
103
49
104
51
109
47
99
47
99
49
103
45
95
45
96
48
101
43
91
44
93
46
98
41
87
42
88
44
93
38
80
41
87
43
91
36
76
38
81
40
85
34
71
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
35
POWER
CONSUMED
WATTS
116
147
189
SENSIBLE
RECOVERY
EFFICIENCY
63
59
57
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
114
58
95
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-33
BROAN – NUTONE LLC
Model: HRV90HS  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21.8% Supply 32.9% Exhaust  Low Temp. Imbalance Factor: 1.1
EXT. STATIC
PRESSURE
Pa
in wg
25
50
75
100
125
150
175
200
225
250
275
300
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
52
50
48
46
44
41
39
37
36
33
32
28
110
108
102
97
93
87
82
79
76
70
67
60
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
53
51
49
47
45
42
39
38
37
34
32
29
112
108
104
100
95
89
84
81
77
72
68
61
57
54
52
50
48
46
44
42
40
37
36
34
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
18
39
24
50
40
85
-13
23
121
115
110
106
103
97
92
90
84
79
77
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
37
66
44
65
68
59
48
56
57
APPARENT
SENSIBLE
EFFECTIVENESS
78
74
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.01
84
0.03
BROAN – NUTONE LLC
Model: HRV90HT  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21.8% Supply 32.9% Exhaust  Low Temp. Imbalance Factor: 1.1
EXT. STATIC
PRESSURE
Pa
in wg
25
50
75
100
125
150
175
200
225
250
275
300
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
52
50
48
46
44
41
39
37
36
33
32
28
110
108
102
97
93
87
82
79
76
70
67
60
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
53
51
49
47
45
42
39
38
37
34
32
29
112
108
104
100
95
89
84
81
77
72
68
61
57
54
52
50
48
46
44
42
40
37
36
34
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
18
39
24
50
40
85
-13
23
48
121
115
110
106
103
97
92
90
84
79
77
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
37
66
44
65
68
59
56
57
APPARENT
SENSIBLE
EFFECTIVENESS
78
74
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.01
84
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-34
BROAN – NUTONE LLC
Model: HRV 100H  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 22% Exhaust  Low Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
177
88
186
90
190
50
0.2
80
169
84
178
86
182
75
0.3
77
163
81
171
81
171
100
0.4
69
146
72
153
76
161
125
0.5
61
130
65
137
66
139
150
0.6
46
98
49
103
52
110
175
0.7
38
81
40
85
32
67
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
46
97
65
138
-13
26
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
54
75
78
67
124
64
55
62
67
APPARENT
SENSIBLE
EFFECTIVENESS
83
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.03
0.01
-0.02
89
0.05
BROAN - NUTONE LLC
Model: HRV 200H  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 23% Exhaust  Low Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
50
0.2
119
253
125
264
126
268
75
0.3
118
250
124
262
118
251
100
0.4
111
235
116
245
114
241
125
0.5
102
216
106
224
107
226
150
0.6
87
185
91
193
96
204
175
0.7
76
160
79
167
81
172
200
0.8
57
120
59
124
57
121
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET AIR
FLOW
L/S
CFM
51
109
73
155
102
215
-13
52
110
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
92
70
128
65
191
62
104
60
APPARENT
SENSIBLE
EFFECTIVENESS
77
72
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.02
-0.01
94
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-35
BRYANT
Model: ERVBBLHA1200-A  Options Installed:
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg .01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 24.8% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
105
222
106
225
106
cfm
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
39
80
54
114
79
167
POWER
CONSUMED
WATTS
84
113
169
SENSIBLE
RECOVERY
EFFICIENCY
60
58
56
-25
-13
31
65
116
41
+35
+35
+95
+95
39
82
81
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.60
0.53
0.45
86
TOTAL RECOVERY EFFICIENCY
52
0.47
BRYANT
Model: ERVBBSHB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
21
45
30
64
COOLING
+95
21
+35
44
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
42
67
60
65
72
63
58
60
71
55
42
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
79
0.61
75
0.55
71
0.48
75
0.60
71
0.57
TOTAL RECOVERY EFFICIENCY
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-36
BRYANT
Model: ERVBBSVB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
21
45
30
64
COOLING
+95
21
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
42
67
60
65
72
63
58
60
71
55
44
42
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
79
0.61
75
0.55
71
0.48
75
0.60
71
0.57
TOTAL RECOVERY EFFICIENCY
50
BRYANT
Model: HRVBBLHA1150-A  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
81
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
83
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-37
BRYANT
Model: HRVBBLHA1250-A  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust  Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
72
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
0.08
BRYANT
Model: HRVBBLVU1330-B ·Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 4.6
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 15.8% Exhaust ·Low Temp. Imbalance Factor: 0.99
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
168
357
172
364
148
cfm
314
50
0.2
166
352
170
360
139
294
75
0.3
158
334
160
340
132
279
100
0.4
151
321
155
328
126
266
125
0.5
142
300
144
306
117
247
150
0.6
136
288
139
294
109
232
175
0.7
126
267
128
272
100
211
200
0.8
116
246
118
251
93
198
225
0.9
103
219
105
223
84
179
250
1.0
82
173
84
177
74
157
275
1.1
63
133
64
136
33
70
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
219
80
290
74
436
70
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
86
183
117
249
-25
-13
55
117
264
+35
+35
+95
+95
85
115
181
245
286
434
74
APPARENT
SENSIBLE
EFFECTIVENESS
94
86
83
LATENT
RECOVERY/MOISTURE
TRANSFER
0.07
0.02
-0.01
89
TOTAL RECOVERY EFFICIENCY
12
9
0.17
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-38
BRYANT
Model: HRVBBSHB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.009 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
45
64
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
BRYANT
Model: HRVBBSVB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.009 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
45
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-39
BRYANT
Model: HRVXXLHB1150-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
81
POWER
CONSUMED
WATTS
67
74
90
SENSIBLE
RECOVERY
EFFICIENCY
67
65
61
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
87
60
76
0.02
BRYANT
Model: HRVXXLHB1200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
105
222
106
225
106
cfm
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
COOLING
+35
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
38
80
54
114
79
167
-13
31
65
+95
39
82
POWER
CONSUMED
WATTS
84
113
169
SENSIBLE
RECOVERY
EFFICIENCY
60
58
56
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
60
53
45
116
41
86
47
81
TOTAL RECOVERY EFFICIENCY
52
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-40
BRYANT
Model: HRVXXLHB1250-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.00 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
106
225
107
227
118
cfm
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
POWER
CONSUMED
WATTS
71
129
SENSIBLE
RECOVERY
EFFICIENCY
65
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
114
60
76
0.03
BRYANT
Model: HRVXXSVU1157  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 31% Exhaust  Low Temp. Imbalance Factor: 1.1
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
92
195
91
cfm
194
50
0.2
86
182
86
183
86
182
75
0.3
80
170
81
171
80
169
100
0.4
74
157
74
158
74
157
125
0.5
67
142
67
143
69
147
150
0.6
62
132
62
133
63
133
175
0.7
55
117
56
118
57
120
200
0.8
47
101
48
101
49
104
225
0.9
40
86
41
87
43
92
250
1.0
33
71
34
71
35
74
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
63
POWER
CONSUMED
WATTS
56
64
86
SENSIBLE
RECOVERY
EFFICIENCY
70
68
64
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
79
61
83
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-41
CARRIER CORPORATION
Model: ERVCCLHA1200-A  Options Installed:
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
105
222
106
225
106
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
39
80
54
114
79
167
POWER
CONSUMED
WATTS
84
113
169
SENSIBLE
RECOVERY
EFFICIENCY
60
58
56
-25
-13
31
65
116
41
+35
+35
+95
+95
39
82
81
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.60
0.53
0.45
86
TOTAL RECOVERY EFFICIENCY
52
0.47
CARRIER CORPORATION
Model: ERVCCSHB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
21
45
30
64
COOLING
+95
21
+35
44
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
42
67
60
65
72
63
58
60
71
55
42
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
79
0.61
75
0.55
71
0.48
75
0.60
71
0.57
TOTAL RECOVERY EFFICIENCY
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-42
CARRIER CORPORATION
Model: ERVCCSVB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
21
45
30
64
COOLING
+95
21
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
42
67
60
65
72
63
58
60
71
55
44
42
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
79
0.61
75
0.55
71
0.48
75
0.60
71
0.57
TOTAL RECOVERY EFFICIENCY
50
CARRIER CORPORATION
Model: HRVCCLHA1150-A  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
85
180
86
182
92
cfm
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
81
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
83
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-43
CARRIER CORPORATION
Model: HRVCCLHA1250-A  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust  Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
72
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
0.08
CARRIER CORPORATION
Model: HRVCCLVU1330-B  Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 4.6
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 15.8% Exhaust  Low Temp. Imbalance Factor: 0.99
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
168
357
172
364
148
cfm
314
50
0.2
166
352
170
360
139
294
75
0.3
158
334
160
340
132
279
100
0.4
151
321
155
328
126
266
125
0.5
142
300
144
306
117
247
150
0.6
136
288
139
294
109
232
175
0.7
126
267
128
272
100
211
200
0.8
116
246
118
251
93
198
225
0.9
103
219
105
223
84
179
250
1.0
82
173
84
177
74
157
275
1.1
63
133
64
136
33
70
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
219
80
290
74
436
70
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
86
183
117
249
-25
-13
55
117
264
+35
+35
+95
+95
85
115
181
245
286
434
74
APPARENT
SENSIBLE
EFFECTIVENESS
94
86
83
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.07
0.02
-0.01
89
TOTAL RECOVERY EFFICIENCY
12
9
0.07
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-44
CARRIER CORPORATION
Model: HRVCCSHB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.009 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
45
64
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
CARRIER CORPORATION
Model: HRVCCSVB1100-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.009 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
45
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-45
CARRIER CORPORATION
Model: HRVXXLHB1150-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
81
POWER
CONSUMED
WATTS
67
74
90
SENSIBLE
RECOVERY
EFFICIENCY
67
65
61
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
87
60
76
0.02
CARRIER CORPORATION
Model: HRVXXLHB1200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
105
222
106
225
106
cfm
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
COOLING
+35
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
38
80
54
114
79
167
-13
31
65
+95
39
82
POWER
CONSUMED
WATTS
84
113
169
SENSIBLE
RECOVERY
EFFICIENCY
60
58
56
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
60
53
45
116
41
86
47
81
TOTAL RECOVERY EFFICIENCY
52
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-46
CARRIER
Model: HRVXXLHB1250-A  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.00 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
106
225
107
227
118
cfm
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
POWER
CONSUMED
WATTS
71
129
SENSIBLE
RECOVERY
EFFICIENCY
65
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
114
60
76
0.03
CARRIER CORPORATION
Model: HRVXXSVU1157  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 31% Exhaust  Low Temp. Imbalance Factor: 1.1
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
92
195
91
cfm
194
50
0.2
86
182
86
183
86
182
75
0.3
80
170
81
171
80
169
100
0.4
74
157
74
158
74
157
125
0.5
67
142
67
143
69
147
150
0.6
62
132
62
133
63
133
175
0.7
55
117
56
118
57
120
200
0.8
47
101
48
101
49
104
225
0.9
40
86
41
87
43
92
250
1.0
33
71
34
71
35
74
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
63
POWER
CONSUMED
WATTS
56
64
86
SENSIBLE
RECOVERY
EFFICIENCY
70
68
64
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
79
61
83
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-47
FANTECH
Model: FLEX 100H  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 12% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
69
146
70
148
70
148
50
0.2
61
129
62
132
63
133
75
0.3
55
116
56
118
57
120
100
0.4
49
105
50
107
51
107
125
0.5
45
96
46
97
45
95
150
0.6
41
88
42
89
40
84
175
0.7
38
80
39
82
35
73
200
0.8
34
73
35
74
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
33
69
47
99
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
70
56
67
102
64
72
69
66
APPARENT
SENSIBLE
EFFECTIVENESS
80
75
73
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.08
-0.06
-0.04
78
0.00
FANTECH
Model: SH704 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
45
96
47
100
49
104
50
0.2
40
85
41
88
41
88
75
0.3
32
67
33
70
34
73
100
0.4
26
56
27
58
28
59
125
0.5
20
42
20
43
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
26
55
32
67
39
84
-13
34
73
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
57
40
55
40
54
35
53
APPARENT
SENSIBLE
EFFECTIVENESS
67
63
60
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
0.00
66
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-48
FANTECH
Model: SHR 1504  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio:0.03 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
68
73
56
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
FANTECH
Model: SHR1505R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
85
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
93
63
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
76
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-49
FANTECH
Model: SHR 2004  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
114
243
116
246
120
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
129
154
59
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
FANTECH
Model: SHR 2005R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
114
243
116
246
120
cfm
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
126
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
141
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-50
FANTECH
Model: SHR 3005R  Options Installed: None
Electrical Requirements: Volts: 115 Amps: 2.7
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
126
268
131
277
139
294
50
0.2
124
262
127
270
132
279
75
0.3
116
246
119
253
126
266
100
0.4
109
231
112
238
117
247
125
0.5
103
219
107
226
111
236
150
0.6
96
204
100
211
101
215
175
0.7
93
196
95
202
101
213
200
0.8
89
188
92
194
94
200
250
1.0
77
163
79
168
82
174
300
1.2
69
147
71
151
71
151
350
1.4
56
118
57
121
58
123
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
126
76
212
78
262
78
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
55
117
74
157
-25
-25
-13
-13
57
55
121
117
224
220
+35
+35
+95
+95
54
74
115
159
206
260
72
72
APPARENT
SENSIBLE
EFFECTIVENESS
91
92
91
LATENT
RECOVERY/MOISTURE
TRANSFER
.02
.01
-.09
91
-TOTAL RECOVERY EFFICIENCY
18
17
.09
--
FANTECH
Model: SHR 3205R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 13.4% Exhaust  Low Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
75
0.3
140
297
144
306
153
326
100
0.4
126
267
129
275
141
299
125
0.5
114
243
117
250
125
266
150
0.6
104
222
108
229
115
244
175
0.7
92
195
94
201
103
219
200
0.8
80
171
83
176
89
190
225
0.9
69
147
71
151
79
169
250
1.0
58
124
60
128
71
150
275
1.1
47
101
49
103
55
117
300
1.2
38
81
39
84
45
96
325
1.3
30
63
30
65
31
66
350
1.4
21
44
21
46
18
39
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
56
118
76
162
116
248
-13
58
123
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
136
66
182
66
272
64
168
67
APPARENT
SENSIBLE
EFFECTIVENESS
77
76
74
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.03
79
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-51
FANTECH
Model: VH704  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.04 @ 100 Pa / 0.4 in. wg 0.03 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 7 % Supply 9 % Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
45
96
47
100
49
104
50
0.2
40
85
41
88
41
88
75
0.3
32
67
33
70
34
73
100
0.4
26
56
27
58
28
59
125
0.5
20
42
20
43
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
26
55
32
67
39
84
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
57
40
55
40
54
73
35
53
APPARENT
SENSIBLE
EFFECTIVENESS
67
64
60
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
0.00
66
0.01
FANTECH
Model: VH704 V09  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 15 % Supply 0 % Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
32
32
NET
AIR FLOW
L/S
CFM
30
64
35
75
-13
31
66
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
44
59
44
59
40
53
APPARENT
SENSIBLE
EFFECTIVENESS
67
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
-0.01
72
-0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-52
FANTECH
Model: VHR100R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 12% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
69
146
70
148
70
cfm
148
50
0.2
61
129
62
132
63
133
75
0.3
55
116
56
118
57
120
100
0.4
49
105
50
107
51
107
125
0.5
45
96
46
97
45
95
150
0.6
41
88
42
89
40
84
175
0.7
38
80
39
82
35
73
200
0.8
34
73
35
74
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
33
69
47
99
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
70
56
67
102
64
72
69
66
APPARENT
SENSIBLE
EFFECTIVENESS
80
75
73
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.08
-0.06
-0.04
78
0.00
FANTECH
Model: VHR704  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.04 @ 100 Pa / 0.4 in. wg 0.03 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 7 % Supply 9 % Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
45
96
47
100
49
104
50
0.2
40
85
41
88
41
88
75
0.3
32
67
33
70
34
73
100
0.4
26
56
27
58
28
59
125
0.5
20
42
20
43
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
26
55
32
67
39
84
-13
34
73
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
57
40
55
40
54
35
53
APPARENT
SENSIBLE
EFFECTIVENESS
67
64
60
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
0.00
66
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-53
FANTECH
Model: VHR704 V09  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 15 % Supply 0 % Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
32
32
NET
AIR FLOW
L/S
CFM
30
64
35
75
-13
31
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
44
59
44
59
66
40
53
APPARENT
SENSIBLE
EFFECTIVENESS
67
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
-0.01
72
-0.01
FANTECH
Model: VHR704R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11 % Supply 14 % Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
25
52
30
64
35
75
-13
27
57
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
61
44
59
44
59
42
61
APPARENT
SENSIBLE
EFFECTIVENESS
69
67
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-54
FANTECH
Model: VHR904  Options Installed: Damper
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.10 @ 100 Pa / 0.4 in. wg 0.10 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 12 % Supply 2 % Exhaust  Low Temp. Imbalance Factor: 0.88
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
114
55
116
59
124
50
0.2
50
107
51
109
55
117
75
0.3
48
102
49
104
52
111
100
0.4
46
97
47
99
49
104
125
0.5
42
88
42
90
46
97
150
0.6
37
79
38
80
41
87
175
0.7
33
69
33
70
35
75
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
88
69
175
62
180
61
NET
AIR FLOW
L/S
CFM
28
60
41
88
53
113
°F
32
32
32
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.02
0.02
FANTECH
Model: VHR1404  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 5 % Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
73
56
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.00
0.00
77
-0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-55
FANTECH
Model: VHR1405R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
85
93
63
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
76
0.00
FANTECH
Model: VHR2004  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
114
243
116
246
120
cfm
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
129
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
154
59
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-56
FANTECH
Model: VHR2005R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.01 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
114
243
116
246
120
cfm
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
126
141
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
\
FIELD CONTROLS
Model: FC95HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.9
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
32
69
36
76
41
87
50
0.2
31
66
34
73
40
84
75
0.3
30
64
33
70
39
82
100
0.4
28
60
31
66
37
79
125
0.5
26
55
29
60
36
76
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
61
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-57
FIELD CONTROLS
Model: FC150ERV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply - NA Exhaust - NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
71
151
74
157
73
154
50
0.2
67
141
69
146
69
147
75
0.3
62
132
65
137
67
142
100
0.4
59
124
61
129
61
130
125
0.5
50
107
52
111
55
116
150
0.6
46
98
48
102
48
101
175
0.7
38
81
40
84
41
87
200
0.8
28
60
30
63
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
63
45
96
55
117
COOLING
+95
30
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
69
94
67
108
65
65
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
.50
.42
.38
TOTAL RECOVERY EFFICIENCY
47
68
FIELD CONTROLS
Model: FC155HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
68
144
70
149
80
cfm
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-58
FIELD CONTROLS
Model: FC200HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-59
GENERAL FILTERS, INC. (GENERAL AIRE)
Model: 8160  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
91
194
103
cfm
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
76
72
56
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
GENERAL FILTERS, INC. (GENERAL AIRE)
Model: 8220  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
117
248
118
250
130
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
300
1.2
29
61
29
62
26
54
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
105
58
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-60
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV70D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.03 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 14% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
25
52
30
64
35
75
-13
27
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
61
44
59
44
59
63
42
APPARENT
SENSIBLE
EFFECTIVENESS
69
67
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
73
0.01
61
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV140D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
85
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
93
63
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
76
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-61
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
68
73
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
56
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV150D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
85
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
93
63
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
76
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-62
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
EXT. STATIC
NET SUPPLY
PRESSURE
Pa
in wg
AIR FLOW
L/s
cfm
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
114
243
116
246
120
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
GROSS AIR FLOW
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
129
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
154
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
59
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV200D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
EXT. STATIC
NET SUPPLY
PRESSURE
Pa
in wg
AIR FLOW
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
114
243
116
246
120
254
50
0.2
109
230
110
233
115
244
75
0.3
103
218
104
221
106
225
100
0.4
95
201
96
204
101
215
125
0.5
86
182
87
185
94
199
150
0.6
78
166
79
168
87
184
175
0.7
71
151
72
154
79
168
200
0.8
65
137
66
139
71
151
225
0.9
59
125
60
127
64
136
250
1.0
53
112
53
113
56
118
275
1.1
46
98
47
99
51
108
300
1.2
42
88
42
90
44
93
325
1.3
37
78
37
79
39
83
350
1.4
31
66
32
67
35
75
375
1.5
26
55
26
56
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
126
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
141
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-63
GOODMAN INDOOR AIR QUALITY PRODUCTS
Model: HRV300D  Options Installed: None
Electrical Requirements: Volts: 115 Amps: 2.7
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
126
268
131
277
139
294
50
0.2
124
262
127
270
132
279
75
0.3
116
246
119
253
126
266
100
0.4
109
231
112
238
117
247
125
0.5
103
219
107
226
111
236
150
0.6
96
204
100
211
101
215
175
0.7
93
196
95
202
101
213
200
0.8
89
188
92
194
94
200
250
1.0
77
163
79
168
82
174
300
1.2
69
147
71
151
71
151
350
1.4
56
118
57
121
58
123
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
55
117
74
157
POWER
CONSUMED
WATTS
126
212
262
SENSIBLE
RECOVERY
EFFICIENCY
76
78
78
-25
-25
-13
-13
57
55
121
117
224
220
72
72
+35
+35
+95
+95
54
74
115
159
206
260
APPARENT
SENSIBLE
EFFECTIVENESS
91
92
91
LATENT
RECOVERY/MOISTURE
TRANSFER
.02
.01
-.09
91
-TOTAL RECOVERY EFFICIENCY
18
17
.09
--
HONEYWELL, INC.
Model: VNT5070E1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.3% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.75
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
49
105
49
105
46
97
50
0.2
46
97
47
99
41
86
75
0.3
44
92
44
93
41
86
100
0.4
37
80
38
81
34
73
125
0.5
34
73
35
74
29
63
150
0.6
29
62
29
63
25
52
175
0.7
23
48
23
49
18
37
200
0.8
22
46
22
47
10
20
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-15
°F
+32
+32
5
NET
AIR FLOW
L/S
CFM
20
41
30
64
16
35
COOLING
+95
19
POWER
CONSUMED
WATTS
30
36
27
SENSIBLE
RECOVERY
EFFICIENCY
65
64
54
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.47
0.40
0.39
TOTAL RECOVERY EFFICIENCY
+35
41
30
43
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-64
HONEYWELL, INC.
Model: VNT5070H1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
47
99
48
100
48
102
50
0.2
44
93
45
94
43
92
75
0.3
39
83
40
84
38
80
100
0.4
35
75
35
75
36
78
125
0.5
30
65
30
66
32
68
150
0.6
27
56
27
57
25
52
175
0.7
22
46
22
47
19
41
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
19
40
30
65
-13
18
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
28
64
40
59
37
30
55
APPARENT
SENSIBLE
EFFECTIVENESS
72
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
73
-0.01
HONEYWELL, INC.
Model: VNT5150E1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9.4% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.74
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
99
210
99
211
50
0.2
89
189
91
193
91
193
75
0.3
88
187
84
179
84
178
100
0.4
75
159
76
162
76
162
125
0.5
70
148
71
150
69
147
150
0.6
62
131
63
133
62
131
175
0.7
55
116
55
118
55
117
200
0.8
49
104
50
106
48
102
225
0.9
42
90
43
91
43
92
250
1.0
36
77
37
78
40
86
275
1.1
32
68
32
69
32
69
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
38
80
56
118
POWER
CONSUMED
WATTS
58
76
96
SENSIBLE
RECOVERY
EFFICIENCY
65
65
62
APPARENT
SENSIBLE
EFFECTIVENESS
76
73
70
52
78
TOTAL RECOVERY EFFICIENCY
34
-15
5
26
55
59
+35
+95
30
64
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.32
0.29
0.26
0.26
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-65
HONEYWELL, INC.
Model: VNT5150H1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
91
193
91
194
103
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
76
72
56
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
HONEYWELL, INC.
Model: VNT5200E1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5.7% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.77
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
115
244
116
247
108
230
50
0.2
106
225
107
228
101
215
75
0.3
98
208
99
210
95
202
100
0.4
88
188
89
190
83
177
125
0.5
81
173
82
175
74
157
150
0.6
71
150
71
152
67
142
175
0.7
65
139
66
140
60
127
200
0.8
57
122
58
124
52
110
225
0.9
49
105
50
106
42
89
250
1.0
40
86
41
87
67
74
275
1.1
34
72
34
73
30
63
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
37
78
50
107
71
150
POWER
CONSUMED
WATTS
74
80
102
SENSIBLE
RECOVERY
EFFICIENCY
71
72
69
APPARENT
SENSIBLE
EFFECTIVENESS
81
79
77
58
82
TOTAL RECOVERY EFFICIENCY
48
-15
5
36
75
65
+35
+95
35
75
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.44
0.41
0.35
0.27
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-66
HONEYWELL, INC.
Model: VNT5200H1000  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
117
248
118
250
130
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
105
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
58
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: DH 7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.94
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
89
189
90
191
113
239
50
0.2
81
173
82
174
104
221
75
0.3
75
159
75
160
94
200
100
0.4
69
146
69
148
84
179
125
0.5
62
132
63
133
77
163
150
0.6
57
121
58
122
66
140
175
0.7
53
112
53
113
57
121
200
0.8
46
98
47
99
48
102
225
0.9
40
85
40
86
40
85
250
1.0
34
73
35
74
35
74
275
1.1
30
63
30
64
28
60
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
68
43
92
56
119
-13
32
67
POWER
CONSUMED
WATTS
90
104
114
SENSIBLE
RECOVERY
EFFICIENCY
68
67
65
APPARENT
SENSIBLE
EFFECTIVENESS
82
78
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
92
64
84
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-67
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: PE 7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9.4% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.74
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
97
207
99
210
99
cfm
211
50
0.2
89
189
91
193
91
193
75
0.3
88
187
84
179
84
178
100
0.4
75
159
76
162
76
162
125
0.5
70
148
71
150
69
147
150
0.6
62
131
63
133
62
131
175
0.7
55
116
55
118
55
117
200
0.8
49
104
50
106
48
102
225
0.9
42
90
43
91
43
92
250
1.0
36
77
37
78
40
86
275
1.1
32
68
32
69
32
69
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
38
80
56
118
POWER
CONSUMED
WATTS
58
76
96
SENSIBLE
RECOVERY
EFFICIENCY
65
65
62
APPARENT
SENSIBLE
EFFECTIVENESS
76
73
70
52
78
TOTAL RECOVERY EFFICIENCY
34
-15
5
26
55
59
+35
+95
30
64
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.32
0.29
0.26
0.26
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: PE 10.22  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5.7% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.77
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
115
244
116
247
108
cfm
230
50
0.2
106
225
107
228
101
215
75
0.3
98
208
99
210
95
202
100
0.4
88
188
89
190
83
177
125
0.5
81
173
82
175
74
157
150
0.6
71
150
71
152
67
142
175
0.7
65
139
66
140
60
127
200
0.8
57
122
58
124
52
110
225
0.9
49
105
50
106
42
89
250
1.0
40
86
41
87
67
74
275
1.1
34
72
34
73
30
63
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
37
78
50
107
71
150
POWER
CONSUMED
WATTS
74
80
102
SENSIBLE
RECOVERY
EFFICIENCY
71
72
69
APPARENT
SENSIBLE
EFFECTIVENESS
81
79
77
58
82
TOTAL RECOVERY EFFICIENCY
48
-15
5
36
75
65
+35
+95
35
75
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.44
0.41
0.35
0.27
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-68
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: PH7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
91
193
91
194
103
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
76
72
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
56
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: PH 10.22  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
117
248
118
250
130
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
300
1.2
29
61
29
62
26
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
54
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
105
58
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-69
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: RNC 1.5  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
91
194
103
cfm
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
76
72
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
56
IMPERIAL AIR TECHNOLOGIES, INC. GREENTEK)
Model: RNC 2.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
117
248
118
250
130
cfm
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
300
1.2
29
61
29
62
26
54
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
105
58
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-70
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: Solace XPH 1.5  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.00 @100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 8% Exhaust  Low Temp. Imbalance Factor: .90
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
72
153
72
153
67
142
50
0.2
67
142
68
143
61
129
75
0.3
61
130
62
130
55
116
100
0.4
55
117
55
118
47
101
125
0.5
49
103
49
103
41
87
150
0.6
42
88
42
89
34
73
175
0.7
35
75
35
75
27
59
200
0.8
28
61
28
61
22
46
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
84
50
106
-13
32
POWER
CONSUMED
WATTS
52
64
74
SENSIBLE
RECOVERY
EFFICIENCY
75
73
70
APPARENT
SENSIBLE
EFFECTIVENESS
84
80
77
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
49
62
81
0.00
68
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: Solace XPH 2.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 4% Exhaust  Low Temp. Imbalance Factor: .82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
122
258
126
260
120
cfm
254
50
0.2
114
241
115
242
111
235
75
0.3
105
223
106
225
103
218
100
0.4
98
207
99
209
94
199
125
0.5
89
189
90
190
85
180
150
0.6
81
172
82
174
76
161
175
0.7
72
152
73
154
67
142
200
225
0.8
63
133
64
135
58
123
0.9
56
119
57
121
50
106
250
1.0
48
102
48
102
42
89
275
1.1
41
87
42
88
35
74
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
29
61
43
91
60
127
-13
31
66
POWER
CONSUMED
WATTS
62
74
92
SENSIBLE
RECOVERY
EFFICIENCY
78
76
73
APPARENT
SENSIBLE
EFFECTIVENESS
90
85
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
59
66
88
-0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-71
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.12 DD (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 36.8% Exhaust  Low Temp. Imbalance Factor: 1.31
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
59
125
62
131
64
135
50
0.2
52
109
54
114
59
124
75
0.3
49
104
52
109
55
115
100
0.4
45
95
47
100
49
105
125
0.5
39
83
41
87
46
97
150
0.6
34
71
35
74
37
79
175
0.7
28
60
30
63
32
68
200
0.8
23
49
24
51
26
55
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
32
67
41
87
POWER
CONSUMED
WATTS
76
86
104
SENSIBLE
RECOVERY
EFFICIENCY
61
59
55
APPARENT
SENSIBLE
EFFECTIVENESS
78
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.12 DD (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 36.8% Exhaust  Low Temp. Imbalance Factor: 1.31
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
59
125
62
131
64
135
50
0.2
52
109
54
114
59
124
75
0.3
49
104
52
109
55
115
100
0.4
45
95
47
100
49
105
125
0.5
39
83
41
87
46
97
150
0.6
34
71
35
74
37
79
175
0.7
28
60
30
63
32
68
200
0.8
23
49
24
51
26
55
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
32
67
41
87
POWER
CONSUMED
WATTS
76
86
104
SENSIBLE
RECOVERY
EFFICIENCY
61
59
55
APPARENT
SENSIBLE
EFFECTIVENESS
78
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-72
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.12 FSD (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.82
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
56
119
67
142
50
0.2
51
109
53
112
62
132
75
0.3
45
95
47
100
58
123
100
0.4
39
84
40
85
53
113
125
0.5
35
75
36
76
47
100
150
0.6
31
65
32
68
42
90
175
0.7
27
58
28
59
35
75
200
0.8
23
49
24
21
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
44
94
54
116
POWER
CONSUMED
WATTS
82
108
124
SENSIBLE
RECOVERY
EFFICIENCY
61
57
52
APPARENT
SENSIBLE
EFFECTIVENESS
74
68
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.12 FSD (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.82
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
56
119
67
142
50
0.2
51
109
53
112
62
132
75
0.3
45
95
47
100
58
123
100
0.4
39
84
40
85
53
113
125
0.5
35
75
36
76
47
100
150
0.6
31
65
32
68
42
90
175
0.7
27
58
28
59
35
75
200
0.8
23
49
24
21
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
44
94
54
116
POWER
CONSUMED
WATTS
82
108
124
SENSIBLE
RECOVERY
EFFICIENCY
61
57
52
APPARENT
SENSIBLE
EFFECTIVENESS
74
68
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-73
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.80 FSD ERV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.3% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.75
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
49
105
49
105
46
97
50
0.2
46
97
47
99
41
86
75
0.3
44
92
44
93
41
86
100
0.4
37
80
38
81
34
73
125
0.5
34
73
35
74
29
63
150
0.6
29
62
29
63
25
52
175
0.7
23
48
23
49
18
37
200
0.8
22
46
22
47
10
20
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-15
°F
+32
+32
5
NET
AIR FLOW
L/S
CFM
20
41
30
64
16
35
POWER
CONSUMED
WATTS
30
36
27
SENSIBLE
RECOVERY
EFFICIENCY
65
64
54
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.47
0.40
0.39
TOTAL RECOVERY EFFICIENCY
COOLING
+35
+95
19
41
30
43
IMPERIAL AIR TECHNOLOGIES, INC. (GREENTEK)
Model: SS 3.80 FSD HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
47
99
48
100
48
102
50
0.2
44
93
45
94
43
92
75
0.3
39
83
40
84
38
80
100
0.4
35
75
35
75
36
78
125
0.5
30
65
30
66
32
68
150
0.6
27
56
27
57
25
52
175
0.7
22
46
22
47
19
41
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
19
40
30
65
-13
18
37
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
28
64
40
59
30
55
APPARENT
SENSIBLE
EFFECTIVENESS
72
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
73
-0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-74
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: DH 7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.94
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
89
189
90
191
113
239
50
0.2
81
173
82
174
104
221
75
0.3
75
159
75
160
94
200
100
0.4
69
146
69
148
84
179
125
0.5
62
132
63
133
77
163
150
0.6
57
121
58
122
66
140
175
0.7
53
112
53
113
57
121
200
0.8
46
98
47
99
48
102
225
0.9
40
85
40
86
40
85
250
1.0
34
73
35
74
35
74
275
1.1
30
63
30
64
28
60
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
68
43
92
56
119
-13
32
POWER
CONSUMED
WATTS
90
104
114
SENSIBLE
RECOVERY
EFFICIENCY
68
67
65
APPARENT
SENSIBLE
EFFECTIVENESS
82
78
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
92
64
84
0.04
67
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: PE 7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9.4% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.74
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
97
207
99
210
99
cfm
211
50
0.2
89
189
91
193
91
193
75
0.3
88
187
84
179
84
178
100
0.4
75
159
76
162
76
162
125
0.5
70
148
71
150
69
147
150
0.6
62
131
63
133
62
131
175
0.7
55
116
55
118
55
117
200
0.8
49
104
50
106
48
102
225
0.9
42
90
43
91
43
92
250
1.0
36
77
37
78
40
86
275
1.1
32
68
32
69
32
69
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
38
80
56
118
LATENT
RECOVERY/MOISTURE
TRANSFER
0.32
0.29
0.26
POWER
CONSUMED
WATTS
58
76
96
SENSIBLE
RECOVERY
EFFICIENCY
65
65
62
APPARENT
SENSIBLE
EFFECTIVENESS
76
73
70
52
78
TOTAL RECOVERY EFFICIENCY
34
-15
5
26
55
59
+35
+95
30
64
66
0.26
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-75
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: PE 10.22  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5.7% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.77
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
115
244
116
247
108
230
50
0.2
106
225
107
228
101
215
75
0.3
98
208
99
210
95
202
100
0.4
88
188
89
190
83
177
125
0.5
81
173
82
175
74
157
150
0.6
71
150
71
152
67
142
175
0.7
65
139
66
140
60
127
200
0.8
57
122
58
124
52
110
225
0.9
49
105
50
106
42
89
250
1.0
40
86
41
87
67
74
275
1.1
34
72
34
73
30
63
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
37
78
50
107
71
150
POWER
CONSUMED
WATTS
74
80
102
SENSIBLE
RECOVERY
EFFICIENCY
71
72
69
APPARENT
SENSIBLE
EFFECTIVENESS
81
79
77
58
82
TOTAL RECOVERY EFFICIENCY
48
-15
5
36
75
65
+35
+95
35
75
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.44
0.41
0.35
0.27
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: PH7.15  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
91
194
103
cfm
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
76
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
72
56
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-76
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: PH 10.22  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
117
248
118
250
130
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
300
1.2
29
61
29
62
26
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
54
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
120
105
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
58
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: RNC 1.5  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
91
193
91
194
103
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
76
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
66
80
63
94
60
72
56
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
73
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-77
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: RNC 2.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.3% Supply 0.2% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
117
248
118
250
130
cfm
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
100
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
300
1.2
29
61
29
62
26
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
54
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
106
61
132
58
150
55
105
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
72
0.01
58
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: Solace XPH 1.5  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 8% Exhaust  Low Temp. Imbalance Factor: .90
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
72
153
72
153
67
142
50
0.2
67
142
68
143
61
129
75
0.3
61
130
62
130
55
116
100
0.4
55
117
55
118
47
101
125
0.5
49
103
49
103
41
87
150
0.6
42
88
42
89
34
73
175
0.7
35
75
35
75
27
59
200
0.8
28
61
28
61
22
46
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
62
40
84
50
106
-13
32
68
POWER
CONSUMED
WATTS
52
64
74
SENSIBLE
RECOVERY
EFFICIENCY
75
73
70
APPARENT
SENSIBLE
EFFECTIVENESS
84
80
77
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
49
62
81
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-78
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: Solace XPH 2.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 4% Exhaust  Low Temp. Imbalance Factor: .82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
122
258
126
260
120
cfm
254
50
0.2
114
241
115
242
111
235
75
0.3
105
223
106
225
103
218
100
0.4
98
207
99
209
94
199
125
0.5
89
189
90
190
85
180
150
0.6
81
172
82
174
76
161
175
0.7
72
152
73
154
67
142
200
225
0.8
63
133
64
135
58
123
0.9
56
119
57
121
50
106
250
1.0
48
102
48
102
42
89
275
1.1
41
87
42
88
35
74
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
29
61
43
91
60
127
-13
31
66
POWER
CONSUMED
WATTS
62
74
92
SENSIBLE
RECOVERY
EFFICIENCY
78
76
73
APPARENT
SENSIBLE
EFFECTIVENESS
90
85
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
59
66
88
-0.01
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.12 DD (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 36.8% Exhaust  Low Temp. Imbalance Factor: 1.31
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
59
125
62
131
64
135
50
0.2
52
109
54
114
59
124
75
0.3
49
104
52
109
55
115
100
0.4
45
95
47
100
49
105
125
0.5
39
83
41
87
46
97
150
0.6
34
71
35
74
37
79
175
0.7
28
60
30
63
32
68
200
0.8
23
49
24
51
26
55
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
32
67
41
87
POWER
CONSUMED
WATTS
76
86
104
SENSIBLE
RECOVERY
EFFICIENCY
61
59
55
APPARENT
SENSIBLE
EFFECTIVENESS
78
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-79
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.12 DD (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 36.8% Exhaust  Low Temp. Imbalance Factor: 1.31
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
59
125
62
131
64
135
50
0.2
52
109
54
114
59
124
75
0.3
49
104
52
109
55
115
100
0.4
45
95
47
100
49
105
125
0.5
39
83
41
87
46
97
150
0.6
34
71
35
74
37
79
175
0.7
28
60
30
63
32
68
200
0.8
23
49
24
51
26
55
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
51
32
67
41
87
POWER
CONSUMED
WATTS
76
86
104
SENSIBLE
RECOVERY
EFFICIENCY
61
59
55
APPARENT
SENSIBLE
EFFECTIVENESS
78
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.12 FSD (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.82
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
56
119
67
142
50
0.2
51
109
53
112
62
132
75
0.3
45
95
47
100
58
123
100
0.4
39
84
40
85
53
113
125
0.5
35
75
36
76
47
100
150
0.6
31
65
32
68
42
90
175
0.7
27
58
28
59
35
75
200
0.8
23
49
24
21
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
44
94
54
116
POWER
CONSUMED
WATTS
82
108
124
SENSIBLE
RECOVERY
EFFICIENCY
61
57
52
APPARENT
SENSIBLE
EFFECTIVENESS
74
68
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-80
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.12 FSD (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.4% Supply 9.6% Exhaust  Low Temp. Imbalance Factor: 0.82
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
56
119
67
142
50
0.2
51
109
53
112
62
132
75
0.3
45
95
47
100
58
123
100
0.4
39
84
40
85
53
113
125
0.5
35
75
36
76
47
100
150
0.6
31
65
32
68
42
90
175
0.7
27
58
28
59
35
75
200
0.8
23
49
24
21
27
57
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
44
94
54
116
POWER
CONSUMED
WATTS
82
108
124
SENSIBLE
RECOVERY
EFFICIENCY
61
57
52
APPARENT
SENSIBLE
EFFECTIVENESS
74
68
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.80 FSD ERV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.3% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.75
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
49
105
49
105
46
97
50
0.2
46
97
47
99
41
86
75
0.3
44
92
44
93
41
86
100
0.4
37
80
38
81
34
73
125
0.5
34
73
35
74
29
63
150
0.6
29
62
29
63
25
52
175
0.7
23
48
23
49
18
37
200
0.8
22
46
22
47
10
20
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-15
°F
+32
+32
5
NET
AIR FLOW
L/S
CFM
20
41
30
64
16
35
POWER
CONSUMED
WATTS
30
36
27
SENSIBLE
RECOVERY
EFFICIENCY
65
64
54
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.47
0.40
0.39
TOTAL RECOVERY EFFICIENCY
COOLING
+35
+95
19
41
30
43
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-81
IMPERIAL AIR TECHNOLOGIES, INC. (IMPERIAL)
Model: SS 3.80 FSD HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.85
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 11.8% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
47
99
48
100
48
102
50
0.2
44
93
45
94
43
92
75
0.3
39
83
40
84
38
80
100
0.4
35
75
35
75
36
78
125
0.5
30
65
30
66
32
68
150
0.6
27
56
27
57
25
52
175
0.7
22
46
22
47
19
41
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
19
40
30
65
-13
18
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
28
64
40
59
37
30
55
APPARENT
SENSIBLE
EFFECTIVENESS
72
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
73
-0.01
KENMORE
Model: ES 1.5  Options Installed: Damper
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 22.6% Supply 35.6% Exhaust  Low Temp. Imbalance Factor: 1.1
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
89
189
89
190
87
cfm
185
50
0.2
83
177
84
179
83
177
75
0.3
79
167
79
169
79
167
100
0.4
74
156
74
158
73
155
125
0.5
69
147
69
148
68
146
150
0.6
64
136
64
137
63
133
175
0.7
59
126
60
127
58
123
200
0.8
54
115
54
116
51
108
225
0.9
47
100
47
101
45
96
250
1.0
40
86
41
87
38
80
275
1.1
35
74
35
75
31
65
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
-25
°F
+32
+32
+32
+32
-13
NET
AIR FLOW
L/S
CFM
23
49
30
64
38
81
57
122
29
61
POWER
CONSUMED
WATTS
24
26
32
54
40
SENSIBLE
RECOVERY
EFFICIENCY
75
74
73
67
64
APPARENT
SENSIBLE
EFFECTIVENESS
83
80
78
72
89
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
0.01
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-82
LENNOX
Model: ERV3-150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply - NA Exhaust - NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
71
151
74
157
73
154
50
0.2
67
141
69
146
69
147
75
0.3
62
132
65
137
67
142
100
0.4
59
124
61
129
61
130
125
0.5
50
107
52
111
54
116
150
0.6
46
98
48
102
48
101
175
0.7
38
81
40
84
41
87
200
0.8
28
60
30
63
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
-25
-13
+35
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
69
94
67
108
65
NET
AIR FLOW
L/S
CFM
30
63
45
96
55
117
30
65
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
.50
.42
.38
TOTAL RECOVERY EFFICIENCY
47
68
LENNOX
Model: ERV3-200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
65
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
64
98
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-83
LENNOX
Model: HRV3-095  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .9
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.5% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
36
76
40
84
49
cfm
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
98
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
HEATING
°C
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-25
-13
29
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
61
76
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
.03
.04
86
.02
68
LENNOX
Model: HRV3-095GDX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
36
76
40
84
49
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
98
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
61
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-84
LENNOX
Model: HRV3-195  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 4.3% Exhaust  Low Temp. Imbalance Factor: .93
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
101
216
108
229
103
219
92
195
97
207
96
205
85
181
91
193
90
192
74
158
79
168
84
179
68
144
72
153
77
164
59
125
63
133
69
146
50
107
53
114
61
130
34
72
36
76
51
109
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
-25
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
35
73
46
98
54
114
73
155
-13
53
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
82
88
78
98
78
123
75
112
97
72
APPARENT
SENSIBLE
EFFECTIVENESS
92
88
86
82
LATENT
RECOVERY/MOISTURE
TRANSFER
0.10
0.07
0.05
0.02
88
0.01
LENNOX
Model: HRV3-150 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
HEATING
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°C
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-85
LENNOX
Model: HRV3-150GDX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
LENNOX
Model: HRV3-200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2.2% Supply 10.8% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
HEATING
°C
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-25
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-86
LENNOX
Model: HRV3-200GDX  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
LENNOX
Model: HRV3-300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.9
Exhaust Air Transfer Ratio: 0.06 @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 4% Supply 3% Exhaust  Low Temp. Imbalance Factor: 0.90
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
02
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
110
232
117
247
123
261
100
212
107
226
117
248
96
202
102
215
112
238
86
183
92
195
105
222
77
163
82
174
95
202
68
144
72
153
88
187
58
123
62
131
79
166
43
92
46
98
68
144
36
76
38
81
55
117
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
66
140
96
203
-13
62
132
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
118
79
132
77
207
74
125
70
APPARENT
SENSIBLE
EFFECTIVENESS
90
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.14
0.05
0.04
88
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-87
NAPOLEON
Model: NP150HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
NAPOLEON
Model: NP200HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-88
NU-AIR VENTILATION SYSTEMS, INC.
Model: CEA13  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .7
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18.3% Supply 25.3%Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
143
68
144
82
174
50
0.2
58
124
59
125
71
150
75
0.3
51
109
52
110
64
135
100
0.4
47
104
48
101
58
122
125
0.5
43
92
44
93
49
104
150
0.6
37
78
37
79
44
93
175
0.7
30
63
30
64
41
86
200
0.8
22
46
22
47
34
72
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
116
-13
28
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
50
71
80
64
90
63
60
69
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
73
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.00
82
0.00
NU-AIR VENTILATION SYSTEMS, INC.
Model: CEA20-D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 6%Exhaust  Low Temp. Imbalance Factor: 0.87
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
179
86
183
92
196
50
0.2
83
176
85
180
87
184
75
0.3
79
169
81
173
82
174
100
0.4
76
162
78
165
78
166
125
0.5
70
149
72
153
72
154
150
0.6
65
138
66
141
67
142
175
0.7
59
125
60
128
60
127
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
140
60
158
59
178
59
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
40
86
54
116
64
135
-25
-13
56
118
176
+35
+95
54
114
156
57
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.03
73
TOTAL RECOVERY EFFICIENCY
24
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-89
NU-AIR VENTILATION SYSTEMS, INC.
Model: EL1300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .7
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18.3% Supply 25.3%Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
64
136
65
137
78
165
50
0.2
56
118
56
119
67
142
75
0.3
47
103
49
104
60
128
100
0.4
45
95
45
96
55
116
125
0.5
41
87
42
88
46
99
150
0.6
35
74
35
75
42
88
175
0.7
28
60
29
61
39
82
200
0.8
21
44
21
45
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
116
-13
28
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
50
71
80
64
90
63
60
69
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
73
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.00
82
0.00
NU-AIR VENTILATION SYSTEMS, INC.
Model: EL1650  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 6%Exhaust  Low Temp. Imbalance Factor: 0.87
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
83
176
84
179
86
cfm
183
50
0.2
79
167
80
169
81
171
75
0.3
71
152
74
155
75
158
100
0.4
66
141
67
142
68
144
125
0.5
61
130
62
132
63
134
150
0.6
56
118
58
120
58
123
175
0.7
49
104
49
105
53
112
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
29
62
41
86
54
115
-13
30
63
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
65
62
63
76
61
53
59
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
-0.01
78
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-90
NU-AIR VENTILATION SYSTEMS, INC.
Model: ES100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.7
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17% Supply 24%Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
69
147
71
150
81
172
50
0.2
61
131
63
134
72
153
75
0.3
56
118
57
121
64
135
100
0.4
49
104
50
107
58
123
125
0.5
43
91
44
93
52
111
150
0.6
36
76
37
78
43
92
175
0.7
30
64
31
66
37
79
200
0.8
24
52
25
53
30
64
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
26
54
31
66
40
85
-13
25
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
48
70
52
68
72
65
53
53
65
APPARENT
SENSIBLE
EFFECTIVENESS
79
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
82
0.0
NU-AIR VENTILATION SYSTEMS, INC.
Model: ES150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .7
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18.3% Supply 25.3%Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
143
68
144
82
174
50
0.2
58
124
59
125
71
150
75
0.3
51
109
52
110
64
135
100
0.4
47
104
48
101
58
122
125
0.5
43
92
44
93
49
104
150
0.6
37
78
37
79
44
93
175
0.7
30
63
30
64
41
86
200
0.8
22
46
22
47
34
72
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
116
-13
28
60
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
50
71
80
64
90
63
69
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
73
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.00
82
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-91
NU-AIR VENTILATION SYSTEMS, INC.
Model: ES170  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 6%Exhaust  Low Temp. Imbalance Factor: 0.87
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
87
185
88
188
91
193
50
0.2
83
176
84
178
85
180
75
0.3
75
160
76
163
78
166
100
0.4
70
148
71
150
71
152
125
0.5
64
137
65
139
67
141
150
0.6
58
124
59
126
61
130
175
0.7
52
110
52
111
55
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
29
62
41
86
54
115
-13
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
65
62
63
76
61
63
53
59
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
-0.01
78
0.02
NU-AIR VENTILATION SYSTEMS, INC.
Model: ES210  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.5% Supply 29.8% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
107
227
108
230
133
282
50
0.2
96
203
97
206
124
262
75
0.3
92
194
93
196
115
244
100
0.4
84
177
84
179
105
222
125
0.5
76
162
78
164
97
206
150
0.6
70
149
71
150
89
188
175
0.7
62
130
62
132
78
165
200
0.8
54
115
55
116
68
144
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
46
97
51
107
-13
43
91
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
70
82
66
86
65
89
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
74
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.05
0.03
0.02
77
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-92
NU-AIR VENTILATION SYSTEMS, INC.
Model: NU-145  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .7
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18.3% Supply 25.3%Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
143
68
144
82
174
50
0.2
58
124
59
125
71
150
75
0.3
51
109
52
110
64
135
100
0.4
47
104
48
101
58
122
125
0.5
43
92
44
93
49
104
150
0.6
37
78
37
79
44
93
175
0.7
30
63
30
64
41
86
200
0.8
22
46
22
47
34
72
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
116
-13
28
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
50
71
80
64
90
63
60
69
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
73
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.01
0.00
82
0.00
NU-AIR VENTILATION SYSTEMS, INC.
Model: NU165  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 6%Exhaust  Low Temp. Imbalance Factor: 0.87
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
87
185
88
188
91
193
50
0.2
83
176
84
178
85
180
75
0.3
75
160
76
163
78
166
100
0.4
70
148
71
150
71
152
125
0.5
64
137
65
139
67
141
150
0.6
58
124
59
126
61
130
175
0.7
52
110
52
111
55
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
29
62
41
86
54
115
-13
30
63
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
65
62
63
76
61
53
59
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
-0.01
78
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-93
NU-AIR VENTILATION SYSTEMS, INC.
Model: NU-175  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 6%Exhaust  Low Temp. Imbalance Factor: 0.87
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
179
86
183
92
196
50
0.2
83
176
85
180
87
184
75
0.3
79
169
81
173
82
174
100
0.4
76
162
78
165
78
166
125
0.5
70
149
72
153
72
154
150
0.6
65
138
66
141
67
142
175
0.7
59
125
60
128
60
127
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
140
60
158
59
178
59
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
40
86
54
116
64
135
-25
-13
56
118
176
+35
+95
54
114
156
57
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.03
73
TOTAL RECOVERY EFFICIENCY
24
0.03
NU-AIR VENTILATION SYSTEMS, INC.
Model: NU205  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.5% Supply 29.8% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
107
227
108
230
133
282
50
0.2
96
203
97
206
124
262
75
0.3
92
194
93
196
115
244
100
0.4
84
177
84
179
105
222
125
0.5
76
162
78
164
97
206
150
0.6
70
149
71
150
89
188
175
0.7
62
130
62
132
78
165
200
0.8
54
115
55
116
68
144
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
46
97
51
107
-13
43
91
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
70
82
66
86
65
89
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
74
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.05
0.03
0.02
77
0.00
Rev. 09/01/2012
Section 3-94
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV96 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
45
96
47
100
49
104
50
0.2
40
85
41
88
41
88
75
0.3
32
67
33
70
34
73
100
0.4
26
56
27
58
28
59
125
0.5
20
42
20
43
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
26
55
32
67
39
84
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
57
40
55
40
54
73
35
APPARENT
SENSIBLE
EFFECTIVENESS
67
63
60
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
0.00
66
0.01
53
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV96 V09  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.4
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15.2% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
52
30
64
35
75
-13
31
66
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
61
44
59
44
59
40
53
APPARENT
SENSIBLE
EFFECTIVENESS
69
67
56
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.00
-0.01
72
-0.01
Rev. 09/01/2012
Section 3-95
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV 140  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio:0.03 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
72
60
98
59
144
55
68
73
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
56
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV 150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio:0.03 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
181
87
184
84
180
50
0.2
80
170
82
174
79
169
75
0.3
75
159
76
162
75
159
100
0.4
70
149
71
151
68
146
125
0.5
65
138
66
141
64
136
150
0.6
60
128
61
130
59
125
175
0.7
55
116
56
119
54
114
200
0.8
49
104
50
106
47
100
225
0.9
43
91
43
92
41
87
250
1.0
36
77
37
79
35
75
275
1.1
30
63
30
64
29
61
300
1.2
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
73
56
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
Rev. 09/01/2012
Section 3-96
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV155  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
85
93
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
63
76
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
0.00
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRV160  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa / 0.4 in. wg 0.02 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 11% Supply 19% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
88
188
50
0.2
82
174
84
178
84
178
75
0.3
77
164
79
168
79
168
100
0.4
71
152
73
156
74
158
125
0.5
65
137
66
139
68
146
150
0.6
57
121
59
125
63
133
175
0.7
50
107
51
109
57
121
200
0.8
46
97
46
97
51
109
225
0.9
41
87
42
89
45
95
250
1.0
40
85
40
85
39
83
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
40
85
48
101
75
159
-13
40
85
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
60
94
62
140
60
93
63
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
76
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.02
-0.01
0.00
Rev. 09/01/2012
Section 3-97
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PHRV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
25
50
75
100
125
150
175
200
225
250
275
300
325
350
375
in wg
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
L/s
114
109
103
95
86
78
71
65
59
53
46
42
37
31
26
GROSS AIR FLOW
SUPPLY
cfm
243
230
218
201
182
166
151
137
125
112
98
88
78
66
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
L/s
116
110
104
96
87
79
72
66
60
53
47
42
37
32
26
EXHAUST
cfm
246
233
221
204
185
168
154
139
127
113
99
90
79
67
56
L/s
120
115
106
101
94
87
79
71
64
56
51
44
39
35
30
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
cfm
254
244
225
215
199
184
168
151
136
118
108
93
83
75
63
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
129
154
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
59
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PHRVR 96  Options Installed: None
Electrical Requirements: Volts: 120 Amps: .4
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10.6% Supply 13.9% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
41
86
43
91
50
0.2
35
76
36
77
38
81
75
0.3
30
64
31
66
33
70
100
0.4
26
55
26
56
27
58
125
0.5
21
44
21
45
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
52
30
64
35
75
-13
27
63
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
61
44
59
44
59
42
61
APPARENT
SENSIBLE
EFFECTIVENESS
69
67
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0
0
0
73
0.01
Rev. 09/01/2012
Section 3-98
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRVR100R  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 12% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
69
146
70
148
70
148
50
0.2
61
129
62
132
63
133
75
0.3
55
116
56
118
57
120
100
0.4
49
105
50
107
51
107
125
0.5
45
96
46
97
45
95
150
0.6
41
88
42
89
40
84
175
0.7
38
80
39
82
35
73
200
0.8
34
73
35
74
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
33
69
47
99
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
70
56
67
102
64
72
69
66
APPARENT
SENSIBLE
EFFECTIVENESS
80
75
73
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.08
-0.06
-0.04
78
0.00
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Direct Air PHRVR104  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 12% Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
69
146
70
148
70
cfm
148
50
0.2
61
129
62
132
63
133
75
0.3
55
116
56
118
57
120
100
0.4
49
105
50
107
51
107
125
0.5
45
96
46
97
45
95
150
0.6
41
88
42
89
40
84
175
0.7
38
80
39
82
35
73
200
0.8
34
73
35
74
30
63
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
33
69
47
99
-13
34
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
70
56
67
102
64
69
66
APPARENT
SENSIBLE
EFFECTIVENESS
80
75
73
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.08
-0.06
-0.04
78
0.00
Rev. 09/01/2012
Section 3-99
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PHRVR 155  Options Installed: Damper
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 14% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
78
167
80
169
86
182
50
0.2
74
158
75
160
79
168
75
0.3
71
150
72
152
75
160
100
0.4
67
142
68
144
68
145
125
0.5
65
137
66
140
63
135
150
0.6
58
124
59
126
58
123
175
0.7
52
110
53
112
52
110
200
0.8
47
100
48
101
46
98
225
0.9
42
89
43
91
40
84
250
1.0
36
76
36
77
34
71
275
1.1
28
60
28
60
27
58
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
49
104
76
161
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
59
102
61
148
58
68
96
61
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
-0.01
77
0.02
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PHRVR 160  Options Installed: Damper
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 14% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
78
167
80
169
86
182
50
0.2
74
158
75
160
79
168
75
0.3
71
150
72
152
75
160
100
0.4
67
142
68
144
68
145
125
0.5
65
137
66
140
63
135
150
0.6
58
124
59
126
58
123
175
0.7
52
110
53
112
52
110
200
0.8
47
100
48
101
46
98
225
0.9
42
89
43
91
40
84
250
1.0
36
76
36
77
34
71
275
1.1
28
60
28
60
27
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
49
104
76
161
-13
32
68
58
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
59
102
61
148
58
96
61
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
-0.01
77
0.02
Rev. 09/01/2012
Section 3-100
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PHRVR 205  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
325
1.3
350
1.4
375
1.5
NET SUPPLY
AIR FLOW
L/s
cfm
114
243
109
230
103
218
95
201
86
182
78
166
71
151
65
137
59
125
53
112
46
98
42
88
37
78
31
66
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
116
246
120
254
110
233
115
244
104
221
106
225
96
204
101
215
87
185
94
199
79
168
87
184
72
154
79
168
66
139
71
151
60
127
64
136
53
113
56
118
47
99
51
108
42
90
44
93
37
79
39
83
32
67
35
75
26
56
30
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
126
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
141
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: PHRVR210  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 18% Exhaust  Low Temp. Imbalance Factor: 1.09
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
325
1.3
350
1.4
375
1.5
NET SUPPLY
AIR FLOW
L/s
cfm
114
243
109
230
103
218
95
201
86
182
78
166
71
151
65
137
59
125
53
112
46
98
42
88
37
78
31
66
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
116
246
120
254
110
233
115
244
104
221
106
225
96
204
101
215
87
185
94
199
79
168
87
184
72
154
79
168
66
139
71
151
60
127
64
136
53
113
56
118
47
99
51
108
42
90
44
93
37
79
39
83
32
67
35
75
26
56
30
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
59
126
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
108
62
154
62
246
60
141
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
81
0.01
Rev. 09/01/2012
Section 3-101
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
\
Model: Powrmatic PHRVR 305  Options Installed: None
Electrical Requirements: Volts: 115 Amps: 2.7
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 7% Supply 9% Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
126
268
131
277
139
294
50
0.2
124
262
127
270
132
279
75
0.3
116
246
119
253
126
266
100
0.4
109
231
112
238
117
247
125
0.5
103
219
107
226
111
236
150
0.6
96
204
100
211
101
215
175
0.7
93
196
95
202
101
213
200
0.8
89
188
92
194
94
200
250
1.0
77
163
79
168
82
174
300
1.2
69
147
71
151
71
151
350
1.4
56
118
57
121
58
123
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
126
76
212
78
262
78
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
55
117
74
157
-25
-25
-13
-13
57
55
121
117
224
220
+35
+35
+95
+95
54
74
115
159
206
260
72
72
APPARENT
SENSIBLE
EFFECTIVENESS
91
92
91
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.01
-0.09
91
-TOTAL RECOVERY EFFICIENCY
18
17
0.09
---
POWRMATIC OF CANADA, LTD. (DIRECT AIR)
Model: Powrmatic PW150  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.10 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 2% Exhaust  Low Temp. Imbalance Factor: 0.88
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
71
151
72
153
68
145
50
0.2
67
142
68
144
66
139
75
0.3
65
137
65
138
62
132
100
0.4
60
128
61
130
58
123
125
0.5
57
120
57
121
55
116
150
0.6
52
111
53
112
50
105
175
0.7
48
102
49
103
45
95
200
0.8
43
91
43
92
41
86
225
0.9
40
84
40
85
36
76
250
1.0
34
72
34
72
32
67
275
1.1
29
62
30
63
26
56
300
1.2
26
56
27
57
21
44
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
94
61
121
59
168
56
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
39
83
57
121
-25
-25
-13
-13
41
30
87
64
119
86
+35
+35
+95
+95
30
53
64
113
96
163
56
55
APPARENT
SENSIBLE
EFFECTIVENESS
72
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
0.02
69
--TOTAL RECOVERY EFFICIENCY
14
12
0.05
---
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-102
RENEWAIRE LLC
Model Number: BR70  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
41
86
42
89
46
97
50
0.2
34
73
35
75
39
84
75
0.3
28
59
29
61
32
69
100
0.4
21
46
22
47
25
53
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
32
69
COOLING
+95
30
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
94
66
64
94
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.53
TOTAL RECOVERY EFFICIENCY
42
RENEWAIRE LLC
Model Number: BR130  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
cfm
EXHAUST
L/s
cfm
25
0.1
70
148
71
151
75
159
50
0.2
66
141
67
143
69
147
75
0.3
62
132
63
134
64
135
100
0.4
53
113
54
115
56
119
125
0.5
44
94
45
96
47
99
150
0.6
32
69
33
70
29
62
175
0.7
24
52
25
53
21
45
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
58
124
COOLING
+95
59
+35
126
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
121
72
121
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
80
0.55
TOTAL RECOVERY EFFICIENCY
46
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-103
RENEWAIRE LLC
Model Number: EV70  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
43
92
44
93
44
93
50
0.2
36
77
37
79
37
79
75
0.3
29
61
29
62
29
62
100
0.4
22
47
22
48
22
48
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
34
73
COOLING
+95
34
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
84
69
71
83
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
78
0.54
TOTAL RECOVERY EFFICIENCY
47
RENEWAIRE LLC
Model Number: EV130  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
77
165
79
168
79
168
50
0.2
72
153
73
156
73
156
75
0.3
64
137
66
140
66
140
100
0.4
59
126
61
129
61
129
125
0.5
49
104
50
106
50
106
150
0.6
37
79
38
81
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
61
130
COOLING
+95
61
+35
130
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
102
71
102
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.53
TOTAL RECOVERY EFFICIENCY
48
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-104
RENEWAIRE LLC
Model Number: EV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa /0.4 in. wg 0.03 @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
97
207
100
213
109
232
50
0.2
90
192
93
199
104
221
75
0.3
88
186
90
192
101
216
100
0.4
83
176
85
181
96
204
125
0.5
79
168
81
173
88
187
150
0.6
70
149
72
154
76
162
175
0.7
57
122
59
126
68
145
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
85
181
COOLING
+95
85
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
157
78
180
155
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
85
0.62
TOTAL RECOVERY EFFICIENCY
52
RENEWAIRE LLC
Model Number: EV300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg --- @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
100
0.4
147
311
150
317
143
303
125
0.5
139
295
142
301
133
283
150
0.6
131
277
133
282
125
265
175
0.7
121
256
123
261
108
230
200
0.8
101
215
103
219
94
198
225
0.9
90
191
92
195
74
156
250
1.0
80
170
82
174
47
99
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
139
297
COOLING
+95
138
+35
294
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
315
67
313
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
74
0.54
TOTAL RECOVERY EFFICIENCY
46
Rev. 09/01/2012
Section 3-105
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
REVERSOMATIC MFG. LTD.
Model: RERV-D100  Options Installed: Internal Ventilation System Controller
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 32 % Supply 30 % Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
55
116
55
117
50
106
50
0.2
52
111
53
113
48
103
75
0.3
50
106
50
107
47
99
100
0.4
48
103
49
104
45
96
125
0.5
45
97
46
98
44
93
150
0.6
44
94
45
95
41
87
175
0.7
42
89
42
90
39
83
200
0.8
38
81
38
82
35
74
225
0.9
34
73
35
73
29
62
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
62
82
60
92
59
°F
32
32
32
NET
AIR FLOW
L/S
CFM
30
64
36
77
42
89
-25
-13
21
45
71
+35
+35
+95
+95
22
30
46
64
56
70
53
APPARENT
SENSIBLE
EFFECTIVENESS
71
69
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.39
0.36
0.33
73
TOTAL RECOVERY EFFICIENCY
43
40
0.32
REVERSOMATIC MFG. LTD.
Model: RERV-S100  Options Installed: Internal Ventilation System Controller
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 32 % Supply 30 % Exhaust  Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
55
116
55
117
50
106
50
0.2
52
111
53
113
48
103
75
0.3
50
106
50
107
47
99
100
0.4
48
103
49
104
45
96
125
0.5
45
97
46
98
44
93
150
0.6
44
94
45
95
41
87
175
0.7
42
89
42
90
39
83
200
0.8
38
81
38
82
35
74
225
0.9
34
73
35
73
29
62
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
62
82
60
92
59
°F
32
32
32
NET
AIR FLOW
L/S
CFM
30
64
36
77
42
89
-25
-13
21
45
71
+35
+35
+95
+95
22
30
46
64
56
70
53
APPARENT
SENSIBLE
EFFECTIVENESS
71
69
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.39
0.36
0.33
73
TOTAL RECOVERY EFFICIENCY
43
40
0.32
Rev. 09/01/2012
Section 3-106
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
REVERSOMATIC MFG. LTD.
Model: RHRV-D100A  Options Installed: Internal Ventilation System Controller
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 9.2 % Supply 10.3 % Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
60
128
61
130
62
132
50
0.2
59
124
59
126
60
138
75
0.3
57
120
57
122
57
121
100
0.4
54
115
55
116
56
114
125
0.5
52
110
52
111
52
110
150
0.6
50
106
50
107
48
101
175
0.7
47
101
48
102
45
95
200
0.8
45
96
46
97
43
92
225
0.9
42
90
43
91
39
83
250
1.0
38
82
39
83
36
77
275
1.1
33
71
34
71
30
64
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
30
64
36
77
43
91
-13
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
58
84
56
100
55
64
75
60
APPARENT
SENSIBLE
EFFECTIVENESS
70
67
65
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.03
72
0.02
REVERSOMATIC MFG. LTD.
Model: RHRV-S100A  Options Installed: Internal Ventilation System Controller
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 9.2 % Supply 10.3 % Exhaust  Low Temp. Imbalance Factor: 0.97
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
60
128
61
130
62
132
50
0.2
59
124
59
126
60
138
75
0.3
57
120
57
122
57
121
100
0.4
54
115
55
116
56
114
125
0.5
52
110
52
111
52
110
150
0.6
50
106
50
107
48
101
175
0.7
47
101
48
102
45
95
200
0.8
45
96
46
97
43
92
225
0.9
42
90
43
91
39
83
250
1.0
38
82
39
83
36
77
275
1.1
33
71
34
71
30
64
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
30
64
36
77
43
91
-13
30
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
58
84
56
100
55
75
60
APPARENT
SENSIBLE
EFFECTIVENESS
70
67
65
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.03
72
0.02
Rev. 09/01/2012
Section 3-107
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
REVERSOMATIC MFG. LTD.
Model: RHRV-D100P  Options Installed: Internal Ventilation System Controller
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. wg 0.01 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 14.2 % Supply 18.2 % Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
54
116
56
119
50
0.2
52
110
52
111
52
110
75
0.3
49
105
50
106
49
105
100
0.4
47
101
48
102
47
100
125
0.5
44
94
44
96
46
97
150
0.6
41
87
41
87
44
93
175
0.7
38
80
38
81
41
88
200
0.8
34
73
35
74
38
81
225
0.9
31
66
32
67
31
65
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
32
67
36
77
43
91
-13
31
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
76
68
84
67
100
65
65
84
61
APPARENT
SENSIBLE
EFFECTIVENESS
80
77
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.00
75
0.03
RHEEM
Model: 84-ERV-100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @ 100 Pa / 0.4 in. wg 0.06 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 0 % Supply 0 % Exhaust  Low Temp. Imbalance Factor: 0.79
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
82
173
87
184
93
197
50
0.2
78
165
83
175
86
182
75
0.3
72
152
76
162
80
169
100
0.4
67
142
71
151
77
163
125
0.5
55
117
59
124
67
143
150
0.6
46
98
49
104
56
118
175
0.7
36
77
39
82
41
87
200
0.8
30
63
32
67
24
51
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
32
32
32
NET
AIR FLOW
L/S
CFM
29
60
47
100
65
137
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
56
71
80
64
126
60
-15
5
31
65
64
+35
+95
28
59
52
56
APPARENT
SENSIBLE
EFFECTIVENESS
79
73
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.52
0.41
0.36
81
TOTAL RECOVERY EFFICIENCY
45
0.41
Rev. 09/01/2012
Section 3-108
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
RHEEM
Model: 84-ERV-200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: --- @ 100 Pa / 0.4 in. wg 0.06 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.84
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
109
231
116
245
128
271
50
0.2
108
228
114
241
123
260
75
0.3
101
214
107
227
118
249
100
0.4
95
201
101
213
110
233
125
0.5
86
182
91
193
102
217
150
0.6
79
167
84
177
92
195
175
0.7
62
132
66
140
81
172
200
0.8
40
85
42
90
55
116
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
93
69
130
64
°F
+32
+32
NET
AIR FLOW
L/S
CFM
52
110
74
157
-15
-25
+32
-5
96
52
203
110
193
122
+35
+95
50
106
89
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.45
0.38
68
76
TOTAL RECOVERY EFFICIENCY
41
0.30
0.26
RHEEM
Model: 84-HRV-100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @ 100 Pa/0.4 in. wg 0.05 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 22% Exhaust  Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
177
88
186
90
190
50
0.2
80
169
84
178
86
182
75
0.3
77
163
81
171
81
171
100
0.4
69
146
72
153
76
161
125
0.5
61
130
65
137
66
139
150
0.6
46
98
49
103
52
110
175
0.7
38
81
40
85
32
67
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
46
97
65
138
-13
26
55
POWER
CONSUMED
WATTS
54
78
124
SENSIBLE
RECOVERY
EFFICIENCY
75
67
64
APPARENT
SENSIBLE
EFFECTIVENESS
83
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.03
0.01
-0.02
62
67
89
0.05
Rev. 09/01/2012
Section 3-109
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
RHEEM
Model: 84-HRV-200  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: --- @ @100 Pa/0.4 in. wg 0.04 @ 50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 23% Exhaust  Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
50
0.2
119
253
125
264
126
268
75
0.3
118
250
124
262
118
251
100
0.4
111
235
116
245
114
241
125
0.5
102
216
106
224
107
226
150
0.6
87
185
91
193
96
204
175
0.7
76
160
79
167
81
172
200
0.8
57
120
59
124
57
121
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
51
109
73
155
102
215
-13
52
110
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
92
70
128
65
191
62
104
60
APPARENT
SENSIBLE
EFFECTIVENESS
77
72
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-.0.01
-0.02
-0.01
94
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-110
RUUD
Model: 84-ERV-100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @ 100 Pa / 0.4 in. wg 0.06 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 0 % Supply 0 % Exhaust  Low Temp. Imbalance Factor: 0.79
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
82
173
87
184
93
197
50
0.2
78
165
83
175
86
182
75
0.3
72
152
76
162
80
169
100
0.4
67
142
71
151
77
163
125
0.5
55
117
59
124
67
143
150
0.6
46
98
49
104
56
118
175
0.7
36
77
39
82
41
87
200
0.8
30
63
32
67
24
51
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
56
71
80
64
126
60
NET
AIR FLOW
L/S
CFM
29
60
47
100
65
137
°F
32
32
32
-15
5
31
65
64
+35
+95
28
59
52
56
APPARENT
SENSIBLE
EFFECTIVENESS
79
73
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.52
0.41
0.36
81
TOTAL RECOVERY EFFICIENCY
45
0.41
RUUD
Model: 84-ERV-200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: --- @ 100 Pa / 0.4 in. wg 0.06 @50 Pa/0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.84
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
109
231
116
245
128
271
50
0.2
108
228
114
241
123
260
75
0.3
101
214
107
227
118
249
100
0.4
95
201
101
213
110
233
125
0.5
86
182
91
193
102
217
150
0.6
79
167
84
177
92
195
175
0.7
62
132
66
140
81
172
200
0.8
40
85
42
90
55
116
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
52
110
74
157
96
203
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
93
69
130
64
193
60
-15
5
52
110
122
+35
+95
50
106
89
55
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.45
0.38
0.30
76
TOTAL RECOVERY EFFICIENCY
41
0.26
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-111
RUUD
Model: 84-HRV-100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.05 @50 Pa/0.2 in. wg --- @ 100 Pa / 0.4 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 22% Exhaust  Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
177
88
186
90
190
50
0.2
80
169
84
178
86
182
75
0.3
77
163
81
171
81
171
100
0.4
69
146
72
153
76
161
125
0.5
61
130
65
137
66
139
150
0.6
46
98
49
103
52
110
175
0.7
38
81
40
85
32
67
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
46
97
65
138
-13
26
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
54
75
78
67
124
64
55
62
67
APPARENT
SENSIBLE
EFFECTIVENESS
83
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.03
0.01
-0.02
89
0.05
RUUD
Model: 84-HRV-200  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: 0.04 @50 Pa/0.2 in. wg --- @ 100 Pa / 0.4 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 23% Exhaust  Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
50
0.2
119
253
125
264
126
268
75
0.3
118
250
124
262
118
251
100
0.4
111
235
116
245
114
241
125
0.5
102
216
106
224
107
226
150
0.6
87
185
91
193
96
204
175
0.7
76
160
79
167
81
172
200
0.8
57
120
59
124
57
121
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
51
109
73
155
102
215
-13
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
110
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
92
70
128
65
191
62
104
60
APPARENT
SENSIBLE
EFFECTIVENESS
77
72
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-.0.01
-0.02
-0.01
94
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-112
SEARS INDOOR CLEAN AIR SERVICES
Model: Sears155 Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
144
70
149
80
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
SEARS INDOOR CLEAN AIR SERVICES
Model: Sears200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-113
SOLER & PALAU
Model: TR70  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply NA Exhaust NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
43
92
44
93
44
93
50
0.2
36
77
37
79
37
79
75
0.3
29
61
29
62
29
62
100
0.4
22
47
22
48
22
48
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
34
73
COOLING
+95
34
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
84
69
71
83
APPARENT
SENSIBLE
EFFECTIVENESS
78
LATENT
RECOVERY/MOISTURE
TRANSFER
0.54
TOTAL RECOVERY EFFICIENCY
47
SOLER & PALAU
Model: TR130  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply NA Exhaust NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
77
165
79
168
79
168
50
0.2
72
153
73
156
73
156
75
0.3
64
137
66
140
66
140
100
0.4
59
126
61
129
61
129
125
0.5
49
104
50
106
50
106
150
0.6
37
79
38
81
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
61
130
COOLING
+95
61
+35
130
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
102
71
102
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.53
TOTAL RECOVERY EFFICIENCY
48
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-114
SOLER & PALAU
Model: TR200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply NA Exhaust NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
213
109
232
50
0.2
90
192
93
199
104
221
75
0.3
88
186
90
192
101
216
100
0.4
83
176
85
181
96
204
125
0.5
79
168
81
173
88
187
150
0.6
70
149
72
154
76
162
175
0.7
57
122
59
126
68
145
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
85
181
COOLING
+95
85
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
157
78
180
155
APPARENT
SENSIBLE
EFFECTIVENESS
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.62
TOTAL RECOVERY EFFICIENCY
52
SOLER & PALAU
Model: TR300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.3
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply NA Exhaust NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
100
0.4
147
311
150
317
143
303
125
0.5
139
295
142
301
133
283
150
0.6
131
277
133
282
125
265
175
0.7
121
256
123
261
108
230
200
0.8
101
215
103
219
94
198
225
0.9
90
191
92
195
74
156
250
1.0
80
170
82
174
47
99
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
139
297
COOLING
+95
138
+35
294
cfm
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
315
67
313
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
74
0.54
TOTAL RECOVERY EFFICIENCY
46
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-115
STANDEX AIR DISTRIBUTION PRODUCTS
Model: ERV150-E  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply - NA Exhaust - NA  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
71
151
74
157
73
154
50
0.2
67
141
69
146
69
147
75
0.3
62
132
65
137
67
142
100
0.4
59
124
61
129
61
130
125
0.5
50
107
52
111
54
116
150
0.6
46
98
48
102
48
101
175
0.7
38
81
40
84
41
87
200
0.8
28
60
30
63
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
-25
-13
+35
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
70
69
94
67
108
65
NET
AIR FLOW
L/S
CFM
30
63
45
96
55
117
30
65
68
APPARENT
SENSIBLE
EFFECTIVENESS
81
76
73
LATENT
RECOVERY/MOISTURE
TRANSFER
.50
.42
.38
TOTAL RECOVERY EFFICIENCY
47
STANDEX AIR DISTRIBUTION PRODUCTS
Model: ERV200-E  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: NA @100 Pa/0.4 in. wg NA @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: NA% Supply NA% Exhaust  Low Temp. Imbalance Factor: NA
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
89
189
90
191
50
0.2
80
169
83
176
84
179
75
0.3
74
157
77
164
79
167
100
0.4
69
146
72
152
71
150
125
0.5
62
132
65
138
63
134
150
0.6
56
118
58
123
56
119
175
0.7
48
101
50
105
48
102
200
0.8
39
82
41
86
42
89
225
0.9
22
47
24
50
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
+35
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
55
116
+95
+95
30
55
65
117
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
72
97
69
64
98
LATENT
APPARENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
81
.48
76
.61
TOTAL RECOVERY EFFICIENCY
47
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-116
STANDEX AIR DISTRIBUTION PRODUCTS
Model: HRV95SC  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
36
76
40
84
49
104
50
0.2
34
73
38
81
48
101
75
0.3
33
70
37
78
46
96
100
0.4
31
66
34
73
44
94
125
0.5
29
60
32
67
43
91
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
42
89
-13
29
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
61
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
STANDEX AIR DISTRIBUTION PRODUCTS
Model: HRV150SC  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.7% Supply 13.8% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
68
144
70
149
80
cfm
171
50
0.2
63
134
65
139
78
165
75
0.3
59
125
61
129
75
160
100
0.4
53
113
55
117
74
157
125
0.5
43
92
45
95
70
149
150
0.6
34
73
36
76
64
137
175
0.7
28
59
29
61
57
122
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
64
104
63
119
61
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
96
55
117
-25
-13
35
74
96
+35
+95
29
62
77
66
APPARENT
SENSIBLE
EFFECTIVENESS
73
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
78
TOTAL RECOVERY EFFICIENCY
17
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-117
STANDEX AIR DISTRIBUTION PRODUCTS
Model: HRV200SC  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
STANDEX AIR DISTRIBUTION PRODUCTS
Model: HRV300DC  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.9
Exhaust Air Transfer Ratio: 0.06 @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 4% Supply 3% Exhaust  Low Temp. Imbalance Factor: 0.90
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
02
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
110
232
117
247
123
261
100
212
107
226
117
248
96
202
102
215
112
238
86
183
92
195
105
222
77
163
82
174
95
202
68
144
72
153
88
187
58
123
62
131
79
166
43
92
46
98
68
144
36
76
38
81
55
117
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
66
140
96
203
-25
-13
62
+35
+95
132
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
118
79
132
77
207
74
125
70
APPARENT
SENSIBLE
EFFECTIVENESS
90
88
85
LATENT
RECOVERY/MOISTURE
TRANSFER
0.14
0.05
0.04
88
0.04
TOTAL RECOVERY EFFICIENCY
Not tested
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-118
TITAN
Model: THRV70  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.90
Exhaust Air Transfer Ratio: 0.10 @100 Pa/0.4 in. wg 0.08 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply, 22% Exhaust Low  Temp. Imbalance Factor: 1.00
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
32
69
36
76
41
87
50
0.2
31
66
34
73
40
84
75
0.3
30
64
33
70
39
82
100
0.4
28
60
31
66
37
79
125
0.5
26
55
29
60
36
76
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
33
71
43
89
-13
29
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
59
75
58
73
89
73
61
76
68
APPARENT
SENSIBLE
EFFECTIVENESS
88
86
84
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
0.03
0.04
86
0.02
TITAN
Model: THRV100D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3% Supply 7% Exhaust  Low Temp. Imbalance Factor: 0.92
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
74
156
70
160
67
153
50
0.2
69
146
71
150
69
146
75
0.3
63
134
65
137
60
128
100
0.4
59
124
61
127
60
122
125
0.5
54
115
56
117
54
114
150
0.6
49
104
51
106
49
102
175
0.7
45
95
47
98
45
94
200
0.8
40
85
41
87
40
77
225
0.9
33
69
34
71
33
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
85
55
117
-13
36
76
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
74
61
86
61
140
56
96
63
APPARENT
SENSIBLE
EFFECTIVENESS
74
73
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-119
TITAN
Model: THRV120D  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3% Supply 15% Exhaust  Low Temp. Imbalance Factor: 7%
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
142
68
144
72
154
50
0.2
64
137
65
138
69
147
75
0.3
62
131
62
133
66
141
100
0.4
60
128
61
129
64
135
125
0.5
58
123
58
124
60
128
150
0.6
54
115
55
116
58
123
175
0.7
53
113
54
114
55
116
200
0.8
49
105
50
106
51
109
225
0.9
48
102
48
103
48
102
250
1.0
45
96
46
97
45
95
275
1.1
42
90
43
91
41
87
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
32
32
32
NET
AIR FLOW
L/S
CFM
33
70
42
89
56
120
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
76
59
94
57
156
52
67
109
56
APPARENT
SENSIBLE
EFFECTIVENESS
68
67
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.03
0.03
0.03
72
0.01
TITAN
Model: THRV200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 2% Supply 11% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
214
108
230
50
0.2
94
200
97
206
103
218
75
0.3
87
184
90
191
97
207
100
0.4
80
171
84
179
96
203
125
0.5
71
152
76
161
88
187
150
0.6
61
130
66
140
82
174
175
0.7
55
116
60
129
67
143
200
0.8
40
86
46
98
56
118
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
45
96
55
117
-13
51
109
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
81
64
99
63
113
61
119
62
APPARENT
SENSIBLE
EFFECTIVENESS
74
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.03
0.03
73
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-120
TOTALINE (TOTALINE)
Model: P707-SHR1504  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio:0.03 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 5% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.82
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
85
181
87
184
84
180
80
170
82
174
79
169
75
159
76
162
75
159
70
149
71
151
68
146
65
138
66
141
64
136
60
128
61
130
59
125
55
116
56
119
54
114
49
104
50
106
47
100
43
91
43
92
41
87
36
77
37
79
35
75
30
63
30
64
29
61
23
49
24
50
22
46
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
67
51
109
76
161
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
72
60
98
59
144
55
73
56
APPARENT
SENSIBLE
EFFECTIVENESS
73
70
63
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.11
0.00
0.00
77
-0.02
TOTALINE (TOTALINE)
Model: P707-SHR2004  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 8% Supply 0% Exhaust  Low Temp. Imbalance Factor: 0.81
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
300
1.2
325
1.3
350
1.4
375
1.5
NET SUPPLY
AIR FLOW
L/s
cfm
114
243
109
230
103
218
95
201
86
182
78
166
71
151
65
137
59
125
53
112
46
98
42
88
37
78
31
66
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
116
246
120
254
110
233
115
244
104
221
106
225
96
204
101
215
87
185
94
199
79
168
87
184
72
154
79
168
66
139
71
151
60
127
64
136
53
113
56
118
47
99
51
108
42
90
44
93
37
79
39
83
32
67
35
75
26
56
30
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
55
117
90
191
-13
61
129
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
108
62
154
62
246
60
154
59
APPARENT
SENSIBLE
EFFECTIVENESS
77
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.06
0.07
0.00
79
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-121
TRANE
Model Number: TERVR100  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.02 @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
77
165
79
168
79
168
50
0.2
72
153
73
156
73
156
75
0.3
64
137
66
140
66
140
100
0.4
59
126
61
129
61
129
125
0.5
49
104
50
106
50
106
150
0.6
37
79
38
81
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
61
130
COOLING
+95
61
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
102
71
130
102
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.53
TOTAL RECOVERY EFFICIENCY
48
TRANE
Model Number: TERVR200  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa /0.4 in. wg 0.03 @ 50 Pa/0.2 in. wg
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
97
207
100
213
109
232
50
0.2
90
192
93
199
104
221
75
0.3
88
186
90
192
101
216
100
0.4
83
176
85
181
96
204
125
0.5
79
168
81
173
88
187
150
0.6
70
149
72
154
76
162
175
0.7
57
122
59
126
68
145
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
85
181
COOLING
+95
85
+35
180
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
157
78
155
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
85
0.62
TOTAL RECOVERY EFFICIENCY
52
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-122
TRANE
Model Number: TERVR300  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg --- @ 50 Pa/0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
100
0.4
147
311
150
317
143
303
125
0.5
139
295
142
301
133
283
150
0.6
131
277
133
282
125
265
175
0.7
121
256
123
261
108
230
200
0.8
101
215
103
219
94
198
225
0.9
90
191
92
195
74
156
250
1.0
80
170
82
174
47
99
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
+32
NET
AIR FLOW
L/S
CFM
139
297
COOLING
+95
138
+35
294
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
315
67
313
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
74
0.54
TOTAL RECOVERY EFFICIENCY
46
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-123
TRENT METALS (2012) LIMITED
Model: Summeraire NW65 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 6% Supply 5% Exhaust • Low Temp. Imbalance Factor: 1.07
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
42
90
43
91
58
123
50
0.2
37
78
37
79
41
87
75
0.3
33
69
33
70
32
68
100
0.4
29
61
29
61
27
57
125
0.5
25
53
25
54
22
47
150
0.6
23
50
24
50
18
38
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
19
40
31
66
34
72
-13
22
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
50
62
40
61
40
61
47
52
52
APPARENT
SENSIBLE
EFFECTIVENESS
74
68
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.02
0.02
73
0.00
TRENT METALS (2012) LIMITED
Model: Summeraire NW130 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 20% Exhaust • Low Temp. Imbalance Factor: 0.93
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
67
143
70
149
70
149
50
0.2
62
132
65
137
64
136
75
0.3
56
118
58
123
59
125
100
0.4
49
104
51
108
54
113
100
125
0.5
43
91
45
95
47
150
0.6
38
80
40
84
41
86
175
0.7
34
72
35
75
33
71
200
0.8
30
63
31
66
26
57
225
0.9
25
52
25
54
22
47
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
33
70
45
96
55
117
-13
30
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
60
65
94
61
94
60
71
60
APPARENT
SENSIBLE
EFFECTIVENESS
80
70
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.07
0.01
-0.01
76
0.07
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-124
TRENT METALS (2012) LIMITED
Model: Summeraire NW140 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.12
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18% Supply 14% Exhaust • Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
71
151
74
157
64
136
50
0.2
65
138
68
144
61
130
75
0.3
60
127
62
133
58
123
100
0.4
55
117
57
122
55
117
125
0.5
50
107
52
111
52
110
150
0.6
45
96
47
100
48
102
175
0.7
41
87
43
90
44
94
200
0.8
36
76
37
79
41
87
225
0.9
32
68
33
70
37
79
250
1.0
24
52
26
54
34
72
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
63
46
98
55
118
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
80
68
118
63
136
61
69
102
59
APPARENT
SENSIBLE
EFFECTIVENESS
82
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
0.02
82
0.04
TRENT METALS (2012) LIMITED
Model: Summeraire NW160 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.27
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply 14% Exhaust • Low Temp. Imbalance Factor: 0.89
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
178
86
184
110
234
50
0.2
77
163
79
169
103
220
75
0.3
71
152
74
157
99
210
100
0.4
63
134
65
139
91
194
125
0.5
55
116
56
120
81
173
150
0.6
43
92
45
96
67
143
175
0.7
23
49
24
51
53
113
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
95
54
114
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
76
90
71
101
69
85
69
APPARENT
SENSIBLE
EFFECTIVENESS
86
80
77
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.04
-0.03
88
0.06
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-125
TRENT METALS (2012) LIMITED
Model: Summeraire NW220 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.27
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply 16% Exhaust • Low Temp. Imbalance Factor: 0.95
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
cfm
GROSS AIR FLOW
SUPPLY
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
110
234
112
237
105
223
50
0.2
106
226
108
229
100
214
75
0.3
102
217
103
220
95
203
100
0.4
98
209
100
212
88
187
125
0.5
92
197
94
200
82
175
150
0.6
86
183
87
185
74
157
175
0.7
79
169
81
171
61
129
200
0.8
66
140
67
142
39
82
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
103
68
132
62
158
58
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
40
84
66
140
86
182
-25
-13
34
72
116
+35
+95
42
89
104
61
APPARENT
SENSIBLE
EFFECTIVENESS
77
68
64
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.00
79
TOTAL RECOVERY EFFICIENCY
29
0.03
TRENT METALS (2012) LIMITED
Model: Summeraire NW260 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.7
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17% Supply 18% Exhaust • Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
75
0.3
125
265
133
283
138
294
100
0.4
121
257
129
274
131
279
125
0.5
118
251
126
268
125
266
150
0.6
116
246
123
262
119
254
175
0.7
113
240
120
256
114
243
200
0.8
110
235
118
251
110
234
225
0.9
106
226
114
241
102
217
250
1.0
100
212
106
226
96
205
275
1.1
94
200
101
214
92
196
300
1.2
86
183
92
195
86
182
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
46
97
67
141
100
213
-13
41
88
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
176
69
222
70
400
64
213
66
APPARENT
SENSIBLE
EFFECTIVENESS
86
84
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
87
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-126
TRENT METALS (2012) LIMITED
Model: Summeraire SERV110 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.1
Exhaust Air Transfer Ratio: 0.04 @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
GROSS AIR FLOW
SUPPLY
cfm
L/s
EXHAUST
cfm
L/s
cfm
25
0.1
69
146
72
152
73
154
50
0.2
63
135
66
140
67
143
131
75
0.3
59
126
61
131
62
100
0.4
53
113
55
117
56
119
125
0.5
49
104
51
108
52
110
150
0.6
43
91
44
94
47
100
175
0.7
39
82
40
85
42
88
200
0.8
33
71
35
74
38
80
225
0.9
28
60
29
62
33
70
250
1.0
21
45
22
46
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
45
97
56
119
COOLING
+95
31
+35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
68
68
92
66
114
63
66
70
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
80
0.48
76
0.40
73
0.35
TOTAL RECOVERY EFFICIENCY
45
TRENT METALS (2012) LIMITED
Model: Summeraire SERV130 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @ 100 Pa/0.4 in. wg 0.05 @ 50 Pa / 0.2 in. wg
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
194
96
204
87
cfm
185
50
0.2
84
179
88
188
81
171
159
75
0.3
78
166
82
175
75
100
0.4
72
153
76
161
67
143
125
0.5
62
132
65
139
57
120
150
0.6
54
116
57
122
33
69
175
0.7
24
51
25
54
22
46
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
+35
+35
+35
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
65
46
97
60
128
+95
+95
+95
30
45
60
64
95
128
POWER
CONSUMED
WATTS
60
79
92
57
75
93
SENSIBLE
RECOVERY
EFFICIENCY
68
65
63
APPARENT
LATENT
SENSIBLE
RECOVERY/MOISTURE
EFFECTIVENESS
TRANSFER
77
0.44
73
0.37
70
0.39
TOTAL RECOVERY EFFICIENCY
33
29
28
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-127
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV115RD • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.2
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 17.8% Supply 13.8% Exhaust • Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
71
151
74
157
64
136
50
0.2
65
138
68
144
61
130
75
0.3
60
127
62
133
58
123
100
0.4
55
117
57
122
55
117
125
0.5
50
107
52
111
52
110
150
0.6
45
96
47
100
48
102
175
0.7
41
87
43
90
44
94
200
0.8
36
76
37
79
41
87
225
0.9
32
68
33
70
37
79
250
1.0
24
52
26
54
34
72
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
63
46
98
55
118
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
80
68
118
63
136
61
69
102
59
APPARENT
SENSIBLE
EFFECTIVENESS
82
74
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
0.02
82
0.04
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV120ED • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 18% Supply 11% Exhaust • Low Temp. Imbalance Factor: 0.92
VENTILATION PERFORMANCE
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
NET SUPPLY
AIR FLOW
L/s
cfm
70
150
GROSS AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
73
155
77
163
50
75
100
125
150
62
57
49
31
12
67
60
52
33
13
0.2
0.3
0.4
0.5
0.6
133
121
105*
67
27
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
142
129
111
71
29
73
65
57
47
16
155
138
120
99
35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
100
54
76
57
65
62
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
43
91
31
66
-25
-13
30
64
69
+35
+95
45
95
94
56
APPARENT
SENSIBLE
EFFECTIVENESS
63
66
74
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.08
0.08
73
TOTAL RECOVERY EFFICIENCY
11
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-128
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV130RD • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.03 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.9% Supply 13.8% Exhaust • Low Temp. Imbalance Factor: 0.89
EXT. STATIC
PRESSURE
Pa
in wg
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
178
86
184
110
234
50
0.2
77
163
79
169
103
220
75
0.3
71
152
74
157
99
210
100
0.4
63
134
65
139
91
194
125
0.5
55
116
56
120
81
173
150
0.6
43
92
45
96
67
143
175
0.7
23
49
24
51
53
113
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
45
95
54
114
-13
32
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
76
90
71
101
69
68
85
APPARENT
SENSIBLE
EFFECTIVENESS
86
80
77
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.02
-0.04
-0.03
88
0.06
69
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV150DM • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.03 @ 100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 21% Supply 20% Exhaust • Low Temp. Imbalance Factor: 0.07
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
67
143
70
149
70
149
50
0.2
62
132
65
137
64
136
75
0.3
56
118
58
123
59
125
100
0.4
49
104
51
108
54
113
125
0.5
43
91
45
95
47
100
150
0.6
38
80
40
84
41
86
175
0.7
34
72
35
75
33
71
200
0.8
30
63
31
66
27
57
225
0.9
25
52
25
54
22
47
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
33
70
45
96
55
117
-13
30
64
POWER
CONSUMED
WATTS
60
94
94
SENSIBLE
RECOVERY
EFFICIENCY
65
61
60
APPARENT
SENSIBLE
EFFECTIVENESS
80
70
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.07
0.01
-0.01
71
60
76
0.07
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-129
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV180ED • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14% Supply 0% Exhaust • Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
104
222
106
226
113
241
50
0.2
97
207
99
211
103
219
75
0.3
92
197
94
200
100
213
100
0.4
80
173
82
177
95
202
125
0.5
71
151
73
155
89
189
150
0.6
46
98
47
100
80
171
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
57
121
64
136
80
170
POWER
CONSUMED
WATTS
100
108
128
SENSIBLE
RECOVERY
EFFICIENCY
72
71
67
-25
-13
67
143
108
61
+35
+95
62
132
104
APPARENT
SENSIBLE
EFFECTIVENESS
81
78
74
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.00
80
TOTAL RECOVERY EFFICIENCY
27
0.00
TRENT METALS (2012) LIMITED
Model: SHRV190RD • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 15% Supply 16% Exhaust • Low Temp. Imbalance Factor: 0.95
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
105
223
50
0.2
106
226
108
229
100
214
75
0.3
102
217
103
220
95
203
100
0.4
98
209
100
212
88
187
125
0.5
92
197
94
200
82
175
150
0.6
86
183
87
185
74
157
175
0.7
79
169
81
171
61
129
200
0.8
66
140
67
142
39
82
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
40
84
66
140
86
182
-13
34
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
103
68
132
62
158
58
116
61
APPARENT
SENSIBLE
EFFECTIVENESS
77
68
64
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.00
79
0.03
TOTAL RECOVERY EFFICIENCY
COOLING
+35
+95
42
89
104
29
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-130
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV240RD • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 3.7
Exhaust Air Transfer Ratio: 0.05 in 0.4 in.Wg (100 pa) 0.05 in 0.2 Wg (50 Pa)
Low Temp. Vent Reduction Factor: 16% Supply 18% Exhaust • Low Temp. Imbalance Factor: 0.96
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
75
0.3
125
265
133
283
138
294
100
0.4
121
257
129
274
131
279
125
0.5
118
251
126
268
125
266
150
0.6
116
246
123
262
119
254
175
0.7
113
240
120
256
114
243
200
0.8
110
235
118
251
110
234
225
0.9
106
226
114
241
102
217
250
1.0
100
212
106
226
96
205
275
1.1
94
200
101
214
92
196
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
46
97
67
141
100
213
-25
-13
41
+35
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
176
69
222
70
400
64
88
213
66
APPARENT
SENSIBLE
EFFECTIVENESS
86
84
80
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
87
TOTAL RECOVERY EFFICIENCY
Not tested
0.03
TRENT METALS (2012) LIMITED
Model: Summeraire SHRV124T • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.12
Exhaust Air Transfer Ratio: 0.01 @ 50 pa/0.2 in. Wg 0.01 @ 100 pa/0.4 in. Wg
Low Temp. Vent Reduction Factor: 19.0% Supply 29.9% Exhaust • Low Temp. Imbalance Factor: 1.12
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
73
155
74
157
75
160
50
0.2
69
146
70
148
70
149
75
0.3
64
135
65
137
64
137
100
0.4
57
122
58
124
60
129
125
0.5
52
110
52
111
55
117
150
0.6
46
98
47
100
50
107
175
0.7
39
84
40
85
45
95
200
0.8
34
72
34
73
38
82
225
0.9
28
60
29
61
34
72
250
1.0
22
47
23
48
28
59
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
45
96
55
117
-13
32
68
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
78
73
98
72
124
68
101
64
APPARENT
SENSIBLE
EFFECTIVENESS
86
83
78
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.00
0.01
91
0.04
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-131
vanEE
Model: ERV60H (SP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust • Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
115
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
42
67
60
65
72
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
-25
-25
-13
-13
21
30
45
64
58
71
+35
+95
21
44
42
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.61
0.55
0.48
75
71
TOTAL RECOVERY EFFICIENCY
50
0.60
0.57
vanEE
Model: ERV60H (TP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust • Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
Pa
in wg
L/s
25
0.1
50
0.2
GROSS AIR FLOW
SUPPLY
EXHAUST
cfm
L/s
cfm
L/s
cfm
54
115
55
117
55
117
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
42
67
60
65
72
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
-25
-25
-13
-13
21
30
45
64
58
71
+35
+95
21
44
42
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.61
0.55
0.48
75
71
TOTAL RECOVERY EFFICIENCY
50
0.60
0.57
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-132
vanEE
Model: ERV 90H-V ECM • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16.8 Supply 13.1 Exhaust • Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
76
161
77
163
78
166
50
0.2
74
157
75
158
74
156
75
0.3
69
147
70
149
71
150
100
0.4
66
140
67
142
65
138
125
0.5
59
125
60
127
62
132
150
0.6
55
117
56
119
58
122
175
0.7
50
105
50
107
53
111
200
0.8
44
93
45
95
45
95
225
0.9
37
77
37
79
39
83
250
1.0
29
61
29
62
34
73
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
24
67
30
67
36
65
60
62
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
31
65
39
83
57
122
-25
-13
33
70
39
+35
+95
24
51
24
60
APPARENT
SENSIBLE
EFFECTIVENESS
73
72
71
67
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.55
0.52
0.46
75
TOTAL RECOVERY EFFICIENCY
52
0.61
vanEE
Model: HRV 60H (SP) • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
50
75
100
125
150
175
200
225
250
275
300
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
53
51
48
46
43
41
39
37
34
34
31
29
111
107
101
98
91
88
82
79
73
71
65
61
53
51
48
47
43
42
39
38
35
34
31
29
112
108
102
99
92
88
83
80
74
72
65
62
57
54
52
49
47
45
43
40
37
36
34
32
120
114
110
105
100
96
91
85
79
76
72
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
45
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-133
vanEE
Model: HRV 60H (TP) • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
50
75
100
125
150
175
200
225
250
275
300
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
53
51
48
46
43
41
39
37
34
34
31
29
111
107
101
98
91
88
82
79
73
71
65
61
53
51
48
47
43
42
39
38
35
34
31
29
112
108
102
99
92
88
83
80
74
72
65
62
57
54
52
49
47
45
43
40
37
36
34
32
120
114
110
105
100
96
91
85
79
76
72
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
43
65
58
62
70
59
45
64
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
vanEE
Model: THH 1.0 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust • Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
50
75
100
125
150
175
200
225
250
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
48
47
45
44
41
41
39
37
37
34
102
100
95
93
87
86
83
79
78
73
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
51
50
47
46
43
42
41
39
38
36
107
105
99
98
92
90
88
83
81
76
52
50
48
46
45
43
41
38
36
33
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
35
110
106
103
99
95
91
87
80
76
71
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
116
63
147
59
189
57
114
58
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
95
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-134
vanEE
Model: THSF 104 • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust • Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
50
75
100
125
150
175
200
225
250
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
53
53
50
49
46
45
44
42
41
38
114
112
106
104
99
96
93
88
87
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
56
55
52
51
49
48
46
44
43
40
119
117
111
109
103
101
98
93
91
85
52
50
48
46
45
43
41
38
36
33
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
110
106
103
99
95
91
87
80
76
71
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
116
63
147
59
189
57
35
114
58
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
95
0.01
vanEE
Model: 60H NOVO+ • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.9
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.2% Supply 28.0% Exhaust • Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
72
152
72
153
72
153
50
0.2
63
134
63
135
64
136
75
0.3
56
120
57
120
57
122
100
0.4
49
104
49
105
51
109
96
125
0.5
44
94
44
94
45
150
0.6
37
79
37
79
41
87
175
0.7
32
68
32
69
35
74
200
0.8
26
54
26
55
28
59
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
54
33
70
48
102
-13
26
54
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
73
54
70
84
65
61
64
APPARENT
SENSIBLE
EFFECTIVENESS
81
78
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
84
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-135
vanEE
Model: 90H • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
120
125
0.5
67
141
67
142
57
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
81
83
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
vanEE
Model: 90H NOVO+ • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
81
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
83
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-136
vanEE
Model: 90H-V • Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 20.8% Supply 30.6% Exhaust • Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
91
193
92
195
91
194
50
0.2
86
182
86
183
86
182
75
0.3
80
170
81
171
80
169
100
0.4
74
157
74
158
74
157
125
0.5
67
142
67
143
69
147
150
0.6
62
132
62
133
63
133
175
0.7
55
117
56
118
57
120
200
0.8
47
101
48
101
49
104
225
0.9
40
86
41
87
43
92
250
1.0
33
71
34
71
35
74
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
56
70
64
68
86
64
63
79
61
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
83
0.01
vanEE
Model: 90H-V ECM • Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 22.6% Supply 35.6% Exhaust • Low Temp. Imbalance Factor: 1.10
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
89
189
89
190
87
185
50
0.2
83
177
84
179
83
177
75
0.3
79
167
79
169
79
167
155
100
0.4
74
156
74
158
73
125
0.5
69
147
69
148
68
146
150
0.6
64
136
64
137
63
133
175
0.7
59
126
60
127
58
123
200
0.8
54
115
54
116
51
108
225
0.9
47
100
47
101
45
96
250
1.0
40
86
41
87
38
80
275
1.1
35
74
35
75
31
65
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
-25
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
49
30
64
38
81
57
122
-13
29
61
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
24
75
26
74
32
73
54
67
40
64
APPARENT
SENSIBLE
EFFECTIVENESS
83
80
78
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
0.01
89
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-137
vanEE
Model: 190H • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust • Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
72
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
0.08
vanEE
Model: 190H NOVO+ • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust • Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
0.08
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-138
vanEE
Model: 100H • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
67
67
74
65
90
61
81
87
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
vanEE
Model: 200H • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust • Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
106
225
107
227
118
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
65
129
60
114
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-139
vanEE
Model: 2000HE • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.2
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12.8% Supply 9.4% Exhaust • Low Temp. Imbalance Factor: 0.93
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
109
231
116
246
107
cfm
227
50
0.2
107
227
114
242
103
218
75
0.3
99
209
105
222
97
206
100
0.4
93
197
99
210
93
197
125
0.5
89
189
95
201
88
186
150
0.6
81
171
86
182
81
172
175
0.7
75
159
80
169
76
161
146
200
0.8
67
143
72
153
69
225
0.9
62
131
66
140
58
123
250
1.0
55
116
58
123
50
106
27
1.1
43
92
46
97
35
74
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
158
84
--84
184
79
210
79
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
52
111
55
117
71
151
84
179
-25
-13
57
121
176
+35
+35
+95
+95
55
76
117
162
160
198
72
APPARENT
SENSIBLE
EFFECTIVENESS
95
--90
89
LATENT
RECOVERY/MOISTURE
TRANSFER
0.05
---0.03
0.12
88
TOTAL RECOVERY EFFICIENCY
13
15
-0.04
vanEE
Model: 3000 HE • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 4.6
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.02 @ 55 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 15.8% Exhaust • Low Temp. Imbalance Factor: 0.99
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
168
357
172
364
148
314
50
0.2
166
352
170
360
139
294
75
0.3
158
334
160
340
132
279
100
0.4
151
321
155
328
126
266
125
0.5
142
300
144
306
117
247
150
0.6
136
288
139
294
109
232
175
0.7
126
267
128
272
100
211
200
0.8
116
246
118
251
93
198
225
0.9
103
219
105
223
84
179
250
1.0
82
173
84
177
74
157
275
1.1
63
133
64
136
33
70
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
219
80
290
74
436
70
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
86
183
117
249
-25
-13
55
117
264
+35
+35
+95
+95
85
115
181
245
286
434
74
APPARENT
SENSIBLE
EFFECTIVENESS
94
86
83
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.07
0.02
-0.01
89
TOTAL RECOVERY EFFICIENCY
12
9
0.07
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-140
vanEE
Model: 1001 ERV • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: ---- @100 Pa/0.4 in. wg 0.07 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 22.6% Supply 25.2% Exhaust • Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
76
162
81
171
86
183
50
0.2
70
149
74
157
79
169
75
0.3
64
136
68
144
71
151
100
0.4
58
123
61
130
61
130
125
0.5
50
106
53
113
51
109
150
0.6
39
83
41
88
42
89
175
0.7
31
65
32
69
22
47
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
-13
NET
AIR FLOW
L/S
CFM
30
64
45
96
61
131
33
70
COOLING
+95
30
+35
POWER
CONSUMED
WATTS
62
82
124
100
64
SENSIBLE
RECOVERY
EFFICIENCY
68
67
64
55
APPARENT
SENSIBLE
EFFECTIVENESS
80
77
73
78
LATENT
RECOVERY/MOISTURE
TRANSFER
0.53
0.42
0.37
0.60
TOTAL RECOVERY EFFICIENCY
49
60
vanEE
Model: 1001HRV • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.05 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 22%Exhaust • Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
177
88
186
90
190
50
0.2
80
169
84
178
86
182
75
0.3
77
163
81
171
81
171
100
0.4
69
146
72
153
76
161
125
0.5
61
130
65
137
66
139
150
0.6
46
98
49
103
52
110
175
0.7
38
81
40
85
32
67
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
28
60
46
97
65
138
-13
26
55
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
54
75
78
67
124
64
62
67
APPARENT
SENSIBLE
EFFECTIVENESS
83
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.03
0.01
-0.02
89
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-141
vanEE
Model: 2001 ERV • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 0% Exhaust • Low Temp. Imbalance Factor: 0.84
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
109
231
116
245
128
271
50
0.2
108
228
114
241
123
260
75
0.3
101
214
107
227
118
249
100
0.4
95
201
101
213
110
233
125
0.5
86
182
91
193
102
217
150
0.6
79
167
84
177
92
195
175
0.7
62
132
66
140
81
172
200
0.8
40
85
42
90
55
116
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
93
69
130
64
193
60
NET
AIR FLOW
L/S
CFM
52
110
74
157
96
203
°F
+32
+32
+32
-15
5
52
110
122
+35
+95
50
106
89
55
APPARENT
SENSIBLE
EFFECTIVENESS
76
71
68
LATENT
RECOVERY/MOISTURE
TRANSFER
0.45
0.38
0.30
76
TOTAL RECOVERY EFFICIENCY
41
0.26
vanEE
Model: 2001 HRV • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.9
Exhaust Air Transfer Ratio: ---- @100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 0% Supply 23% Exhaust • Low Temp. Imbalance Factor: 1.0
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
50
0.2
119
253
125
264
126
268
75
0.3
118
250
124
262
118
251
100
0.4
111
235
116
245
114
241
125
0.5
102
216
106
224
107
226
150
0.6
87
185
91
193
96
204
175
0.7
76
160
79
167
81
172
200
0.8
57
120
59
124
57
121
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
51
109
73
155
102
215
-13
52
110
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
92
70
128
65
191
62
104
60
APPARENT
SENSIBLE
EFFECTIVENESS
77
72
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.02
-0.01
94
0.05
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-142
vanEE
Model: NOVO+ 100H • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust • Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
67
67
74
65
90
61
81
87
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
vanEE
Model: NOVO+ 200H • Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust • Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
106
225
107
227
118
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
65
129
60
114
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-143
vanEE
Model: Vigor ERV (SP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25.2% Supply 22.3% Exhaust • Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
39
82
39
84
39
cfm
83
50
0.2
37
78
38
80
37
79
75
0.3
35
75
36
77
35
75
100
0.4
33
70
34
72
34
71
125
0.5
32
67
33
69
32
67
150
0.6
29
62
30
64
29
61
175
0.7
28
59
28
60
27
57
200
0.8
26
55
26
56
24
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
66
50
60
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
35
30
64
-25
-13
17
36
43
+35
+95
17
36
34
56
APPARENT
SENSIBLE
EFFECTIVENESS
77
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.54
75
0.55
TOTAL RECOVERY EFFICIENCY
50
vanEE
Model: Vigor ERV (TP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25.2% Supply 22.3% Exhaust • Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
39
82
39
84
39
83
50
0.2
37
78
38
80
37
79
75
0.3
35
75
36
77
35
75
71
100
0.4
33
70
34
72
34
125
0.5
32
67
33
69
32
67
150
0.6
29
62
30
64
29
61
175
0.7
28
59
28
60
27
57
200
0.8
26
55
26
56
24
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
66
50
60
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
35
30
64
-25
-13
17
36
43
+35
+95
17
36
34
56
APPARENT
SENSIBLE
EFFECTIVENESS
77
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.54
75
0.55
TOTAL RECOVERY EFFICIENCY
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-144
vanEE
Model: Vigor HRV • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.8% Supply 25.3% Exhaust • Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
39
82
39
83
43
90
50
0.2
37
78
38
80
40
86
75
0.3
35
73
35
74
39
82
100
0.4
33
71
34
72
37
78
73
125
0.5
31
66
32
67
35
150
0.6
30
63
30
64
33
71
175
0.7
28
59
28
60
31
65
200
0.8
25
54
26
55
28
60
225
0.9
23
49
24
50
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
36
31
65
-13
18
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
40
55
54
48
38
41
53
APPARENT
SENSIBLE
EFFECTIVENESS
70
59
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
72
0.01
vanEE
Model: Vigor HRV Plus (SP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.4% Supply 23.3% Exhaust • Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
40
85
40
85
50
0.2
38
80
38
81
38
81
75
0.3
36
77
37
78
37
79
74
100
0.4
34
73
35
73
35
125
0.5
33
70
33
71
34
71
150
0.6
31
65
31
66
32
68
175
0.7
29
60
29
61
29
62
200
0.8
26
56
27
57
27
57
225
0.9
25
52
25
53
25
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
20
42
30
64
38
81
18
39
30
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
67
52
61
54
58
42
60
53
55
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
65
81
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
0.02
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-145
vanEE
Model: Vigor HRV Plus (TP) • Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.4% Supply 23.3% Exhaust • Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
40
85
40
85
50
0.2
38
80
38
81
38
81
75
0.3
36
77
37
78
37
79
100
0.4
34
73
35
73
35
74
125
0.5
33
70
33
71
34
71
150
0.6
31
65
31
66
32
68
62
175
0.7
29
60
29
61
29
200
0.8
26
56
27
57
27
57
225
0.9
25
52
25
53
25
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
20
42
30
64
38
81
18
39
30
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
67
52
61
54
58
42
60
53
55
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
65
81
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
0.02
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-146
VENMAR VENTILATION, INC.
Model: AVS 1.5 Constructo  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
81
83
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
60
VENMAR VENTILATION, INC.
Model: AVS 2.0 Constructo  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust  Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
0
0
0
-25
°F
+32
+32
+32
NET AIR
FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
0.08
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-147
VENMAR VENTILATION, INC.
Model: AVS Constructo 1.0 ERV (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
114
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
42
67
60
65
72
63
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
49
30
64
40
84
-25
-25
-13
-13
21
30
45
64
58
71
+35
+95
21
44
42
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.61
0.55
0.48
75
71
TOTAL RECOVERY EFFICIENCY
50
0.60
0.57
VENMAR VENTILATION, INC.
Model: AVS Constructo 1.0 ERV (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 26.3% Supply 22.1% Exhaust  Low Temp. Imbalance Factor: 1.04
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
54
114
55
117
55
117
50
0.2
53
112
54
115
54
114
75
0.3
51
109
53
111
52
110
100
0.4
49
105
50
106
50
106
125
0.5
48
102
49
104
49
103
150
0.6
45
96
47
99
47
99
175
0.7
44
93
45
94
45
94
200
0.8
42
89
43
92
42
88
225
0.9
40
85
41
87
41
87
250
1.0
38
81
39
82
38
81
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
°F
NET
AIR FLOW
L/S
CFM
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
LATENT
RECOVERY/MOISTURE
TRANSFER
+32
23
49
42
67
79
0.61
0
+32
30
64
60
65
75
0.55
0
+32
40
84
72
63
71
0.48
-25
-13
21
45
58
60
75
0.60
-25
-13
30
64
71
55
71
0.57
TOTAL RECOVERY EFFICIENCY
COOLING
+35
+95
21
44
42
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-148
VENMAR VENTILATION, INC.
Model: AVS Constructo 1.0 HRV (SP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
43
65
58
62
70
59
45
64
56
64
60
55
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
78
72
0.01
0.00
VENMAR VENTILATION, INC.
Model: AVS Constructo 1.0 HRV (TP)  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 19.3% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
53
111
53
112
57
120
50
0.2
51
107
51
108
54
114
75
0.3
48
101
48
102
52
110
100
0.4
46
98
47
99
49
105
125
0.5
43
91
43
92
47
100
150
0.6
41
88
42
88
45
96
175
0.7
39
82
39
83
43
91
200
0.8
37
79
38
80
40
85
225
0.9
34
73
35
74
37
79
250
1.0
34
71
34
72
36
76
275
1.1
31
65
31
65
34
72
300
1.2
29
61
29
62
32
68
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
50
30
64
39
83
-13
-13
21
30
45
64
POWER
CONSUMED
WATTS
43
58
70
SENSIBLE
RECOVERY
EFFICIENCY
65
62
59
APPARENT
SENSIBLE
EFFECTIVENESS
74
70
66
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
56
64
60
55
78
72
0.01
0.00
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-149
VENMAR VENTILATION, INC.
Model: AVS Constructo 1.5 V HRV  Options Installed: Dampers
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 20.8% Supply 30.6% Exhaust  Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
91
193
92
195
91
cfm
194
50
0.2
86
182
86
183
86
182
75
0.3
80
170
81
171
80
169
100
0.4
74
157
74
158
74
157
125
0.5
67
142
67
143
69
147
150
0.6
62
132
62
133
63
133
175
0.7
55
117
56
118
57
120
200
0.8
47
101
48
101
49
104
225
0.9
40
86
41
87
43
92
250
1.0
33
71
34
71
35
74
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
WATTS
EFFICIENCY
56
70
64
68
86
64
63
79
61
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
83
0.01
VENMAR VENTILATION, INC.
Model: AVS Constructo 2.0 HRV  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
106
225
107
227
118
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
POWER
CONSUMED
WATTS
71
129
SENSIBLE
RECOVERY
EFFICIENCY
65
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
114
60
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-150
VENMAR VENTILATION, INC.
Model: AVS Duo 1.2  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 16% Exhaust  Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
62
131
63
133
65
137
50
0.2
59
125
60
127
61
130
75
0.3
58
123
59
124
58
123
100
0.4
54
114
55
116
55
117
125
0.5
51
108
52
110
50
107
150
0.6
45
95
45
96
47
99
175
0.7
39
83
40
84
40
85
200
0.8
31
65
31
66
29
62
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
°F
+32
+32
NET
AIR FLOW
L/S
CFM
32
68
56
119
COOLING
+95
31
+35
POWER
CONSUMED
WATTS
108
156
66
SENSIBLE
RECOVERY
EFFICIENCY
77
71
APPARENT
SENSIBLE
EFFECTIVENESS
87
81
LATENT
RECOVERY/MOISTURE
TRANSFER
0.61
0.56
TOTAL RECOVERY EFFICIENCY
75
103
VENMAR VENTILATION, INC.
Model: AVS Duo 1.4  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16% Supply 17% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
68
145
70
148
78
165
50
0.2
65
137
66
140
72
153
75
0.3
60
127
61
129
65
138
100
0.4
57
120
58
123
60
127
125
0.5
49
104
50
106
49
104
150
0.6
43
91
44
93
42
89
175
0.7
30
64
31
66
31
66
200
0.8
22
46
22
47
23
49
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
110
70
164
65
172
64
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
68
47
100
57
121
-25
-13
29
61
120
+35
+35
+95
+95
31
57
66
121
104
168
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.79
0.67
0.60
79
TOTAL RECOVERY EFFICIENCY
69
61
0.65
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-151
VENMAR VENTILATION, INC.
Model: AVS Duo 1.9  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.2
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: Supply Exhaust  Low Temp. Imbalance Factor:
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
97
206
99
211
100
cfm
214
50
0.2
92
196
95
201
95
203
75
0.3
85
181
87
186
90
192
100
0.4
79
169
81
173
85
180
125
0.5
72
153
74
156
79
168
150
0.6
63
134
65
138
70
149
175
0.7
51
108
52
111
62
132
200
0.8
38
81
39
83
50
106
225
0.9
33
69
33
71
35
75
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
0
0
COOLING
+35
°F
+32
+32
NET
AIR FLOW
L/S
CFM
56
119
83
177
+95
55
POWER
CONSUMED
WATTS
137
201
116
SENSIBLE
RECOVERY
EFFICIENCY
69
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.79
0.75
TOTAL RECOVERY EFFICIENCY
70
132
VENMAR VENTILATION, INC.
Model: AVS ERV EKO 1.5  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16.8 Supply 13.1 Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
76
161
77
163
78
166
50
0.2
74
157
75
158
74
156
75
0.3
69
147
70
149
71
150
100
0.4
66
140
67
142
65
138
125
0.5
59
125
60
127
62
132
150
0.6
55
117
56
119
58
122
175
0.7
50
105
50
107
53
111
200
0.8
44
93
45
95
45
95
225
0.9
37
77
37
79
39
83
250
1.0
29
61
29
62
34
73
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
24
67
30
67
36
65
60
62
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
31
65
39
83
57
122
-25
-13
33
70
39
+35
+95
24
51
24
60
APPARENT
SENSIBLE
EFFECTIVENESS
73
72
71
67
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.55
0.52
0.46
75
TOTAL RECOVERY EFFICIENCY
52
0.61
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-152
VENMAR VENTILATION, INC.
Model: AVS HE 1.8  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.2
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.06 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12.8% Supply 9.4% Exhaust  Low Temp. Imbalance Factor: 0.93
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
109
231
116
246
107
227
50
0.2
107
227
114
242
103
218
75
0.3
99
209
105
222
97
206
100
0.4
93
197
99
210
93
197
125
0.5
89
189
95
201
88
186
150
0.6
81
171
86
182
81
172
175
0.7
75
159
80
169
76
161
200
0.8
68
143
72
153
69
145
225
0.9
62
131
66
140
58
123
250
1.0
55
116
58
123
50
106
275
1.1
43
92
46
97
35
74
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
158
84
--84
184
79
210
79
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
52
111
55
117
71
151
84
179
-25
-13
57
121
176
+35
+35
+95
+95
55
76
117
162
160
198
72
APPARENT
SENSIBLE
EFFECTIVENESS
95
--90
89
LATENT
RECOVERY/MOISTURE
TRANSFER
0.05
---0.03
0.12
88
TOTAL RECOVERY EFFICIENCY
13
15
-0.04
VENMAR VENTILATION, INC.
Model: AVS HE 2.6  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 4.6
Exhaust Air Transfer Ratio: --- @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 13.3% Supply 15.8% Exhaust  Low Temp. Imbalance Factor: 0.99
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
168
357
172
364
148
314
50
0.2
166
352
170
360
139
294
75
0.3
158
334
160
340
132
279
100
0.4
151
321
155
328
126
266
125
0.5
142
300
144
306
117
247
150
0.6
136
288
139
294
109
232
175
0.7
126
267
128
272
100
211
200
0.8
116
246
118
251
93
198
225
0.9
103
219
105
223
84
179
250
1.0
82
173
84
177
74
157
275
1.1
63
133
64
136
33
70
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
219
80
290
74
436
70
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
117
86
183
117
249
-25
-13
55
117
264
+35
+35
+95
+95
85
115
181
245
286
434
74
APPARENT
SENSIBLE
EFFECTIVENESS
94
86
83
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.07
0.02
-0.01
89
TOTAL RECOVERY EFFICIENCY
12
9
0.07
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-153
VENMAR VENTILATION, INC.
Model: AVS HRV EKO 1.5  Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 22.6% Supply 35.6% Exhaust  Low Temp. Imbalance Factor: 1.10
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
89
189
89
190
87
cfm
185
50
0.2
83
177
84
179
83
177
75
0.3
79
167
79
169
79
167
100
0.4
74
156
74
158
73
155
125
0.5
69
147
69
148
68
146
150
0.6
64
136
64
137
63
133
175
0.7
59
126
60
127
58
123
200
0.8
54
115
54
116
51
108
225
0.9
47
100
47
101
45
96
250
1.0
40
86
41
87
38
80
275
1.1
35
74
35
75
31
65
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
0
-25
°F
+32
+32
+32
+32
NET
AIR FLOW
L/S
CFM
23
49
30
64
38
81
57
122
-13
29
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
24
75
26
74
32
73
54
67
61
40
64
APPARENT
SENSIBLE
EFFECTIVENESS
83
80
78
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
0.01
0.01
89
0.02
VENMAR VENTILATION, INC.
Model: AVS Kubix ERV (SP)  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25.2% Supply 22.3% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
39
82
39
84
39
83
50
0.2
37
78
38
80
37
79
75
0.3
35
75
36
77
35
75
100
0.4
33
70
34
72
34
71
125
0.5
32
67
33
69
32
67
150
0.6
29
62
30
64
29
61
175
0.7
28
59
28
60
27
57
200
0.8
26
55
26
56
24
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
66
50
60
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
35
30
64
-25
-13
17
36
43
+35
+95
17
36
34
56
APPARENT
SENSIBLE
EFFECTIVENESS
77
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.54
75
0.55
TOTAL RECOVERY EFFICIENCY
50
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-154
VENMAR VENTILATION, INC.
Model: AVS Kubix ERV (TP)  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.03 @100 Pa/0.4 in. wg 0.02 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25.2% Supply 22.3% Exhaust  Low Temp. Imbalance Factor: 1.03
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
39
82
39
84
39
83
50
0.2
37
78
38
80
37
79
75
0.3
35
75
36
77
35
75
100
0.4
33
70
34
72
34
71
125
0.5
32
67
33
69
32
67
150
0.6
29
62
30
64
29
61
175
0.7
28
59
28
60
27
57
200
0.8
26
55
26
56
24
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
34
66
50
60
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
35
30
64
-25
-13
17
36
43
+35
+95
17
36
34
APPARENT
SENSIBLE
EFFECTIVENESS
77
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.59
0.54
75
0.55
56
TOTAL RECOVERY EFFICIENCY
50
VENMAR VENTILATION, INC.
Model: AVS Kubix HRV  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.8% Supply 25.3% Exhaust  Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
39
82
39
83
43
90
50
0.2
37
78
38
80
40
86
75
0.3
35
73
35
74
39
82
100
0.4
33
71
34
72
37
78
125
0.5
31
66
32
67
35
73
150
0.6
30
63
30
64
33
71
175
0.7
28
59
28
60
31
65
200
0.8
25
54
26
55
28
60
225
0.9
23
49
24
50
26
55
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
17
36
31
65
-13
18
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
40
55
54
48
41
53
APPARENT
SENSIBLE
EFFECTIVENESS
70
59
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.02
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-155
VENMAR VENTILATION, INC.
Model: AVS Kubix HRV Plus (SP)  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.4% Supply 23.3% Exhaust  Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
40
85
40
85
50
0.2
38
80
38
81
38
81
75
0.3
36
77
37
78
37
79
100
0.4
34
73
35
73
35
74
125
0.5
33
70
33
71
34
71
150
0.6
31
65
31
66
32
68
175
0.7
29
60
29
61
29
62
200
0.8
26
56
27
57
27
57
225
0.9
25
52
25
53
25
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
67
52
61
54
58
42
60
53
55
NET
AIR FLOW
L/S
CFM
20
42
30
64
38
81
18
39
30
64
°F
+32
+32
+32
-13
-13
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
65
81
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
0.02
0.01
VENMAR VENTILATION, INC.
Model: AVS Kubix HRV Plus (TP)  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.5
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 14.4% Supply 23.3% Exhaust  Low Temp. Imbalance Factor: 1.08
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
40
84
40
85
40
85
50
0.2
38
80
38
81
38
81
75
0.3
36
77
37
78
37
79
100
0.4
34
73
35
73
35
74
125
0.5
33
70
33
71
34
71
150
0.6
31
65
31
66
32
68
175
0.7
29
60
29
61
29
62
200
0.8
26
56
27
57
27
57
225
0.9
25
52
25
53
25
52
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
-25
°F
+32
+32
+32
-13
-13
NET
AIR FLOW
L/S
CFM
20
42
30
64
38
81
18
39
30
64
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
36
67
52
61
54
58
42
60
53
55
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
65
81
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
0.02
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-156
VENMAR VENTILATION, INC.
Model: AVS SOLO 1.5  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
81
83
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
60
VENMAR VENTILATION, INC.
Model: AVS Solo 2.0  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust  Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-13
34
72
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
80
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
.08
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-157
VENMAR VENTILATION, INC.
Model: AVS THH 1.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust  Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
48
102
51
107
52
110
47
100
50
105
50
106
45
95
47
99
48
103
44
93
46
98
46
99
41
87
43
92
45
95
41
86
42
90
43
91
39
83
41
88
41
87
37
79
39
83
38
80
37
78
38
81
36
76
34
73
36
76
33
71
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
35
POWER
CONSUMED
WATTS
116
147
189
SENSIBLE
RECOVERY
EFFICIENCY
63
59
57
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
114
58
95
0.01
VENMAR VENTILATION, INC.
Model: AVS THSF 104  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust  Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
53
114
56
119
52
110
53
112
55
117
50
106
50
106
52
111
48
103
49
104
51
109
46
99
46
99
49
103
45
95
45
96
48
101
43
91
44
93
46
98
41
87
42
88
44
93
38
80
41
87
43
91
36
76
38
81
40
85
33
71
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
35
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
116
63
147
59
189
57
114
58
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
95
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-158
VENMAR VENTILATION, INC.
Model: ERV Constructo 1.5 Quattro  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.02 @ 100 Pa/0.4 in. wg 0.04 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 28.6% Supply 29.5% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
84
179
85
181
92
196
50
0.2
82
173
83
175
88
187
75
0.3
74
156
75
158
85
181
100
0.4
70
148
71
151
77
163
125
0.5
64
135
65
137
67
143
150
0.6
58
124
59
125
54
114
175
0.7
50
105
50
106
33
71
200
0.8
41
87
42
88
20
43
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
66
61
77
60
137
57
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
30
64
46
97
66
141
-25
-13
22
47
92
+35
+95
31
65
63
+35
+95
49
APPARENT
SENSIBLE
EFFECTIVENESS
75
71
69
LATENT
RECOVERY/MOISTURE
TRANSFER
62
58
52
80
TOTAL RECOVERY EFFICIENCY
56
56
VENMAR VENTILATION, INC.
Model: ERV Constructo 2.0 ES  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
105
222
106
225
106
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
84
60
113
58
169
56
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
39
80
54
114
79
167
-25
-13
31
65
116
+35
+35
+95
+95
39
82
81
41
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
60
53
45
86
TOTAL RECOVERY EFFICIENCY
52
47
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-159
VENMAR VENTILATION, INC.
Model: ERV Constructo 2.0 Quattro  Options Installed: none
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 25% Supply 43% Exhaust  Low Temp. Imbalance Factor: 1.28
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
105
222
106
225
106
225
50
0.2
99
209
100
212
104
220
75
0.3
93
198
94
200
100
212
100
0.4
86
183
88
186
93
198
125
0.5
76
162
78
165
87
185
150
0.6
70
148
71
150
75
158
175
0.7
60
128
61
130
56
119
200
0.8
50
107
51
108
29
61
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
84
60
113
58
169
56
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
39
80
54
114
79
167
-25
-13
31
65
116
+35
+35
+95
+95
39
82
81
41
APPARENT
SENSIBLE
EFFECTIVENESS
72
69
66
LATENT
RECOVERY/MOISTURE
TRANSFER
60
53
45
86
TOTAL RECOVERY EFFICIENCY
52
47
VENMAR VENTILATION
Model: ERV DUO 1.5  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.4
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 16% Supply 17% Exhaust  Low Temp. Imbalance Factor: 0.94
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
68
145
70
148
78
165
65
137
66
140
72
153
60
127
61
129
65
138
57
120
58
123
60
127
49
104
50
106
49
104
43
91
44
93
42
89
30
64
31
66
31
66
22
46
22
47
23
49
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
110
70
164
65
172
64
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
68
47
100
57
121
-25
-13
29
+35
+95
31
66
104
79
TOTAL RECOVERY EFFICIENCY
69
+35
+95
57
121
168
61
61
120
64
APPARENT
SENSIBLE
EFFECTIVENESS
80
74
72
LATENT
RECOVERY/MOISTURE
TRANSFER
0.79
0.67
0.60
0.65
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-160
VENMAR VENTILATION
Model: ERV DUO 2.0  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.2
Exhaust Air Transfer Ratio: 0.02 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 16% Exhaust  Low Temp. Imbalance Factor: 0.86
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
97
206
99
211
100
214
92
196
95
201
95
203
85
181
87
186
90
192
79
169
81
173
85
180
72
153
74
156
79
168
63
134
65
138
70
149
51
108
52
111
62
132
38
81
39
83
50
106
33
69
33
71
35
75
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
SUPPLY
TEMPERATURE
°C
HEATING
0
0
°F
+32
+32
NET
AIR FLOW
L/S
CFM
56
119
83
177
COOLING
+95
55
+35
116
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
137
69
201
64
APPARENT
SENSIBLE
EFFECTIVENESS
77
71
LATENT
RECOVERY/MOISTURE
TRANSFER
0.79
0.75
TOTAL RECOVERY EFFICIENCY
70
132
VENMAR VENTILATION
Model: HRV 2600  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.6
Exhaust Air Transfer Ratio: 0.05 @100 Pa/0.4 in. wg --- @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 3.6% Supply 4.2% Exhaust  Low Temp. Imbalance Factor: 1.20
EXT. STATIC
PRESSURE
Pa
in wg
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
VENTILATION PERFORMANCE
NET SUPPLY
GROSS AIR FLOW
AIR FLOW
SUPPLY
EXHAUST
L/s
cfm
L/s
cfm
L/s
cfm
54
114
56
119
52
110
53
112
55
117
50
106
50
106
52
111
49
103
49
104
51
109
47
99
47
99
49
103
45
95
45
96
48
101
43
91
44
93
46
98
41
87
42
88
44
93
38
80
41
87
43
91
36
76
38
81
40
85
34
71
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
24
52
35
74
44
94
-13
16
35
POWER
CONSUMED
WATTS
116
147
189
SENSIBLE
RECOVERY
EFFICIENCY
63
59
57
APPARENT
SENSIBLE
EFFECTIVENESS
85
75
75
LATENT
RECOVERY/MOISTURE
TRANSFER
0.02
0.05
0.01
114
58
95
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-161
VENMAR VENTILATION, INC.
Model: HRV CONSTRUCTO 1.5 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
67
67
74
65
90
61
81
87
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
VENMAR VENTILATION, INC.
Model: HRV CONSTRUCTO 2.0 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
106
225
107
227
118
cfm
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
65
129
60
114
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-162
VENMAR VENTILATION, INC.
Model: HRV NOVO+ 1.5 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
67
67
74
65
90
61
81
87
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
VENMAR VENTILATION, INC.
Model: HRV NOVOFIT 2.0 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
106
225
107
227
118
cfm
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
65
129
60
114
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-163
VENMAR VENTILATION, INC.
Model: HRV SOLO 1.5 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
54
115
-13
38
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
67
67
74
65
90
61
81
87
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
VENMAR VENTILATION, INC.
Model: HRV SOLO 2.0 ES  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.00 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 9% Supply 20% Exhaust  Low Temp. Imbalance Factor: 1.02
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
106
225
107
227
118
cfm
249
50
0.2
102
215
102
216
115
243
75
0.3
96
204
97
205
111
235
100
0.4
90
192
91
193
107
226
125
0.5
83
177
84
179
100
211
150
0.6
76
161
76
162
89
189
175
0.7
67
142
67
143
75
159
SUPPLY
TEMPERATURE
°C
HEATING
0
0
-25
°F
+32
+32
NET
AIR FLOW
L/S
CFM
39
82
61
130
-13
40
84
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
71
65
129
60
114
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
69
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.01
76
0.03
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-164
VENMAR VENTILATION, INC.
Model: NOVOFIT 1.0  Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: .9
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.2% Supply 28% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
72
152
72
153
72
153
50
0.2
63
134
63
135
64
136
75
0.3
56
120
57
120
57
122
100
0.4
49
104
49
105
51
109
125
0.5
44
94
44
94
45
96
150
0.6
37
79
37
79
41
87
175
0.7
32
68
32
69
35
74
200
0.8
26
54
26
55
28
59
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
54
33
70
48
102
-13
26
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
46
73
54
70
84
65
54
61
APPARENT
SENSIBLE
EFFECTIVENESS
81
78
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
84
0.02
64
VENMAR VENTILATION, INC.
Model: NOVOFIT 1.5  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 1.3
Exhaust Air Transfer Ratio: 0.01 @100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 12% Supply 21% Exhaust  Low Temp. Imbalance Factor: 1.01
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
85
180
86
182
92
194
50
0.2
82
174
82
175
86
182
75
0.3
77
163
77
164
81
171
100
0.4
71
150
71
151
71
151
125
0.5
67
141
67
142
57
120
150
0.6
60
128
61
130
40
85
175
0.7
51
108
52
110
27
57
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
40
86
57
120
-13
38
81
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
62
67
75
64
90
61
83
60
APPARENT
SENSIBLE
EFFECTIVENESS
79
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
76
0.02
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-165
VENMAR VENTILATION, INC.
Model: NOVOFIT 2.0  Options Installed:
Electrical Requirements: Volts: 120 Amps: 2.1
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg - @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 10% Supply 13% Exhaust  Low Temp. Imbalance Factor: 0.90
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
110
234
112
237
112
237
50
0.2
103
219
105
223
106
225
75
0.3
98
208
100
211
99
210
100
0.4
89
189
91
192
91
193
125
0.5
84
177
85
180
82
174
150
0.6
71
151
72
153
70
149
175
0.7
64
136
65
138
44
94
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
COOLING
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
66
56
119
86
182
-25
-13
34
+35
+35
+95
+95
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
85
69
124
60
197
53
72
114
62
APPARENT
SENSIBLE
EFFECTIVENESS
81
70
62
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
80
TOTAL RECOVERY EFFICIENCY
Not tested
.08
VENMAR VENTILATION, INC.
Model: PRO215  Options Installed: Defrost
Electrical Requirements: Volts: 120 Amps: 0.9
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 19.2% Supply 28.0% Exhaust  Low Temp. Imbalance Factor: 1.05
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
72
152
72
153
72
153
50
0.2
63
134
63
135
64
136
75
0.3
56
120
57
120
57
122
100
0.4
49
104
49
105
51
109
125
0.5
44
94
44
94
45
96
150
0.6
37
79
37
79
41
87
175
0.7
32
68
32
68
35
74
200
0.8
26
54
26
55
28
59
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
25
54
33
70
48
102
-13
26
54
POWER
CONSUMED
WATTS
46
54
84
SENSIBLE
RECOVERY
EFFICIENCY
73
70
65
APPARENT
SENSIBLE
EFFECTIVENESS
81
78
73
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
61
64
84
0.02
\
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-166
VENMAR VENTILATION, INC.
Model: PRO225  Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 20.8% Supply 30.6% Exhaust  Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
76
161
77
163
77
162
50
0.2
72
152
72
153
72
152
75
0.3
67
142
68
143
67
141
100
0.4
62
131
63
132
62
131
125
0.5
56
119
56
119
58
123
150
0.6
52
110
53
111
53
111
175
0.7
46
98
47
99
48
100
200
0.8
40
84
40
84
41
87
225
0.9
34
72
34
73
36
77
250
1.0
28
59
28
59
29
62
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
63
POWER
CONSUMED
WATTS
56
64
86
SENSIBLE
RECOVERY
EFFICIENCY
70
68
64
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
79
61
83
0.01
VENMAR VENTILATION, INC.
Model: PRO250  Options Installed: Dampers Defrost
Electrical Requirements: Volts: 120 Amps: 1.0
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa/0.4 in. wg 0.01 @ 50 Pa / 0.2 in. wg
Low Temp. Vent Reduction Factor: 20.8% Supply 30.6% Exhaust  Low Temp. Imbalance Factor: 1.06
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
76
161
77
163
77
162
50
0.2
72
152
72
153
72
152
75
0.3
67
142
68
143
67
141
100
0.4
62
131
63
132
62
131
125
0.5
56
119
56
119
58
123
150
0.6
52
110
53
111
53
111
175
0.7
46
98
47
99
48
100
200
0.8
40
84
40
84
41
87
225
0.9
34
72
34
73
36
77
250
1.0
28
59
28
59
29
62
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
32
67
40
86
56
120
-13
30
63
ENERGY PERFORMANCE
POWER
SENSIBLE
CONSUMED
RECOVERY
EFFICIENCY
WATTS
56
70
64
68
86
64
79
61
APPARENT
SENSIBLE
EFFECTIVENESS
78
75
70
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.01
0.01
83
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
Section 3-167
YORK
Model: S1-HRV160 York  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. Wg 0.01 @ 50 Pa / 0.2 in. Wg
Low Temp. Vent Reduction Factor: 11.3% Supply 7.6% Exhaust  Low Temp. Imbalance Factor: 0.94
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
cfm
25
0.1
91
193
91
104
103
217
50
0.2
84
178
85
179
95
201
75
0.3
77
163
77
163
86
183
100
0.4
71
150
71
151
80
169
125
0.5
63
133
63
134
71
152
150
0.6
57
120
57
121
66
138
175
0.7
51
109
51
109
57
121
200
0.8
46
96
46
96
50
106
225
0.9
40
85
40
86
43
91
250
1.0
35
75
36
75
39
82
275
1.1
29
62
29
62
34
71
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
39
83
50
107
-13
36
POWER
CONSUMED
WATTS
72
80
94
SENSIBLE
RECOVERY
EFFICIENCY
66
63
60
APPARENT
SENSIBLE
EFFECTIVENESS
75
72
67
LATENT
RECOVERY/MOISTURE
TRANSFER
-0.01
-0.01
-0.01
72
56
73
0.00
76
YORK
Model: S1-HRV220 York  Options Installed: None
Electrical Requirements: Volts: 120 Amps: 1.5
Exhaust Air Transfer Ratio: 0.01 @ 100 Pa / 0.4 in. Wg 0.01 @ 50 Pa / 0.2 in. Wg
Low Temp. Vent Reduction Factor: 1.03% Supply 1.03% Exhaust  Low Temp. Imbalance Factor: 0.91
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
117
248
118
250
130
cfm
277
50
0.2
108
229
109
231
119
253
75
0.3
102
218
103
220
110
234
00
0.4
94
200
95
202
101
216
125
0.5
85
181
86
183
92
197
150
0.6
77
163
78
165
82
175
175
0.7
69
146
70
148
71
151
200
0.8
61
129
61
131
60
128
225
0.9
52
110
52
111
49
104
250
1.0
45
96
46
97
40
86
275
1.1
37
79
38
80
32
68
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
-25
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
55
118
75
160
87
185
-13
57
120
POWER
CONSUMED
WATTS
106
132
150
SENSIBLE
RECOVERY
EFFICIENCY
61
58
55
APPARENT
SENSIBLE
EFFECTIVENESS
71
65
62
LATENT
RECOVERY/MOISTURE
TRANSFER
0.00
0.00
0.00
105
58
72
0.01
Rev. 09/01/2012
CERTIFIED HEAT AND ENERGY RECOVERY VENTILATORS
ZEHNDER
Model: CA 350 HRV  Options Installed: None
Electrical Requirements: Volts: 230 Amps: 1.77
Exhaust Air Transfer Ratio: 0 @ 100 Pa / 0.4 in. Wg 0 @ 50 Pa / 0.2 in. Wg
Low Temp. Vent Reduction Factor: 0% Supply 0% Exhaust  Low Temp. Imbalance Factor: 1.07
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
PRESSURE
AIR FLOW
GROSS AIR FLOW
SUPPLY
EXHAUST
Pa
in wg
L/s
cfm
L/s
cfm
L/s
25
0.1
123
260
123
261
126
cfm
266
50
0.2
119
251
119
252
124
262
75
0.3
115
243
115
244
121
255
00
0.4
111
236
112
237
117
247
125
0.5
108
229
109
230
113
239
150
0.6
105
223
105
223
109
230
175
0.7
102
216
102
217
105
223
200
0.8
99
210
99
210
102
217
225
0.9
96
203
96
204
100
212
250
1.0
94
198
94
199
98
208
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
°C
HEATING
0
0
0
°F
+32
+32
+32
NET
AIR FLOW
L/S
CFM
31
65
47
99
61
129
POWER
CONSUMED
WATTS
20
32
50
SENSIBLE
RECOVERY
EFFICIENCY
88
87
85
APPARENT
SENSIBLE
EFFECTIVENESS
93
93
91
LATENT
RECOVERY/MOISTURE
TRANSFER
0.01
0.00
0.00
Section 3-168

Similar documents

more information - DASH Home Inspections

more information - DASH Home Inspections Continental Fan Manufacturing Delta Products Fan Am, Inc. Hangzhou Aupu Bathroom & Kitchen Technology Co. Ltd. Homewerks Worldwide Milano Electronics LLC Orbit Industries Qingdao Xingbang Electroni...

More information