VID Fire-Kill Products Range

Transcription

VID Fire-Kill Products Range
VID Fire-Kill Product Catalogue
Year 2015 - rev 1
Catalogue2015
Index
1. Order form. ................................................................................................................................................................... 4
1.1 Model OH automatic nozzles.................................................................................................................................. 4
1.2 All other products ................................................................................................................................................... 5
2. Automatic Low Pressure Watermist Nozzles for wet pipe systems and related products. .......................................... 6
2.1 Automatic Low Pressure Watermist Nozzles type OH. .......................................................................................... 6
2.1.1 Model OH-L1 ................................................................................................................................................... 7
2.1.2 Model OH-L2 ................................................................................................................................................... 7
2.1.3 Model OH-PX1 ................................................................................................................................................. 8
2.1.4 Model OH-SWC................................................................................................................................................ 8
2.1.5 Model OH-CO .................................................................................................................................................. 9
2.1.6 Model OH-OS................................................................................................................................................... 9
2.1.7 Model OH-SW ................................................................................................................................................ 10
2.1.8 Model OH-VSO .............................................................................................................................................. 10
2.2 Rosettes ................................................................................................................................................................ 11
2.2.1 Model OH-R rosette for type OH automatic nozzles .................................................................................... 11
2.3 Installation Spanners ............................................................................................................................................ 11
2.3.1 Model OH-S36 installation nozzle spanner for type OH automatic nozzles ................................................. 11
3. Open Low Pressure Watermist Nozzles and Linear Nozzles for industrial applications where fluid hydrocarbons are
the main risk. .................................................................................................................................................................. 12
3.1 Open Nozzles ........................................................................................................................................................ 12
3.1.1 Model K6 ....................................................................................................................................................... 12
3.1.2 N-pipes for Model K6 nozzle ......................................................................................................................... 13
3.1.3 Hudson & Bengal Type B1 - open full cone low pressure water mist nozzles. ............................................. 14
3.1.4 Biscay Type N-pipe K1 ................................................................................................................................... 14
3.1.5 Tampa Type N-pipe F1................................................................................................................................... 15
4. Nozzles and Systems for defined applications. ........................................................................................................... 17
4.1 Application: Atriums, aulas, halls, multiple seating areas etc. ............................................................................. 17
4.1.1 Model APS – Atrium/hall protection system................................................................................................. 17
4.1.2 Model AU7 – Watermist nozzle for protection of concert halls and other multiple seated areas ............... 18
4.2 Application: Commercial and industrial fryers, and ducts ................................................................................... 19
4.2.1 Model DFI-1 – Small standalone system for commercial fat fryer system ................................................... 19
4.2.2 Model Vesuvius N-pipe Type 2V-BM1 – Linear Nozzle for commercial and industrial fat fryers. ................ 20
4.2.3 Model Etna N-pipe Type I-K1 – Linear Nozzle for commercial and industrial ventilation ducts. ................. 21
4.3 Application: Residential homes, institutions, elderly people homes, etc ............................................................ 22
4.3.1 Model BB – Fire suppression and life safety in residential areas.................................................................. 22
4.3.2 Model BBK – Local fire suppression and life safety in residential areas. ...................................................... 24
4.4 Application: Inventories, rack storages, Conveyor belts, attics, subfloor etc. ..................................................... 24
4.4.1 N-pipes with BM-1, K1 or F1 nozzles – Protection of class A+B fire risks. .................................................... 25
4.4.2 Model RS – protection of racks in inventories. ............................................................................................. 27
4.5 Application: Military, air force, navy .................................................................................................................... 28
4.5.1 Model F48 - deck nozzle ................................................................................................................................ 28
4.5.2 VID Model F102 - aircraft hangar low pressure water mist nozzle ............................................................... 29
4.6 Application: Road tunnels, rail, tunnels, metro tunnels, cable tunnels, etc. ....................................................... 29
4.6.1 Model Tunprotec – Watermist system for protection of infrastructure tunnels. ........................................ 29
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 2 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.7 Application: Rolling stock, train wagons, metro wagons ..................................................................................... 30
4.7.1 Model Wagon – Watermist system for protection on rolling stock. ............................................................ 30
4.7.2 Model BPS – Standalone system for protection of vehicle engine rooms. ................................................... 31
4.8 Application: Underground carparks and garages. ................................................................................................ 31
Open Nozzle - Model Suez & Panama OH-OPX1 .................................................................................................... 32
5. Water spray nozzles. ................................................................................................................................................... 33
5.1 High velocity nozzles............................................................................................................................................. 33
5.1.1 Type HS .......................................................................................................................................................... 33
5.2 Medium velocity nozzles ...................................................................................................................................... 35
5.2.1 Type MS ......................................................................................................................................................... 35
6. Valves .......................................................................................................................................................................... 37
6.1 Control Valves ....................................................................................................................................................... 37
6.1.1 Model C-EL – electrical operated control valve ............................................................................................ 37
6.2 Pre-Action Valves .................................................................................................................................................. 39
6.2.1 Model C-EL-PR – Pre-action valves................................................................................................................ 39
6.3 Alarm Check Valves for wet pipe systems. ........................................................................................................... 39
6.3.1 Model WAC - wet alarm check valve............................................................................................................. 39
6.4 One-shot deluge valves. ....................................................................................................................................... 40
6.4.1 Model SUFA100 – Thermal and electrical activated one-shot valves. .......................................................... 40
6.5 Pressure Reduction Valves ........................................................................................................................................ 41
6.5.1 Model C-PR – Pressure reduction valve ........................................................................................................ 41
7. Detection Systems....................................................................................................................................................... 43
7.1 Flame detectors .................................................................................................................................................... 43
7.1.1 Type DeFlameTec, model VFK-FD1 Flame detector. ..................................................................................... 43
7.2 Heat detectors ...................................................................................................................................................... 44
7.2.1 Model DA-1 – Thermal ”Rate of Rise” detector. ........................................................................................... 44
NB: VID Fire-Kill holds the right to change prices if the DKK to EURO currency changes more than 7.4 ± 0.2
and DKK to GBP currency change more than 8.6± 0.4.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 3 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
1. Order form.
Orders are sent to the closest sales office by e-mail or fax. Find your nearest office on our web page www.vid.eu
The order should minimum contain:
- Costumer name, Costumer order number, Date, VID Fire-Kill order code, Quantity, RAL colour.
1.1 Model OH automatic nozzles
All Model OH nozzles should be ordered with the following code:
S&O no. + NRT no. + Thread no. + RAL no. + Plate no. = [XXXXX] + [YYYY] + [ZZZ] + [QQQQ] + [UU]
S&O no. is the different products sales and order number
The sales & order number for each product can be found below in the pricelist.
NRT no. is Nominal release temperature number:
Nominal release
temperatures
NRT No.
57 ºC
68 ºC
79 ºC
93 ºC
141 ºC
0057
0068
0079
0093
0141
Thread no. is the thread type and size:
Thread type
NRT No.
½” BSP
501
½” BSP-T
502
½” NPT
503
RAL no. is the Plate finish RAL code number:
RAL Colour
RAL No.
Chrome
0000
Pure White
9010
Jet Black
9005
Pure Red
3028
Other RAL colours can be found on:
www.ralcolor.com
Plate no. is plate type:
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 4 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
1.2 All other products
All other product should be ordered with the following code:
S&O no. + Thread no. + RAL no = [XXXX] + [YYY] + [ZZZZ]
S&O no. is the different products sales and order number
The sales & order number for each product can be found below in the pricelist.
Thread no. is the thread type and size:
Some nozzle may not have all threads available.
Thread type
NRT No.
½” BSP
501
½” BSP-T
502
½” NPT
503
3/8” BSP
381
1” BSP
101
1” NPT
103
M8x1mm
810
M10x1mm
110
RAL no. is the Plate finish RAL code number:
Some nozzle may not have the possibility to be painted.
RAL Colour
RAL No.
Chrome
0000
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 5 of 44
Pure White
9010
Jet Black
9005
Pure Red
3028
Other RAL colours can be found on:
www.ralcolor.com
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2. Automatic Low Pressure Watermist Nozzles for wet pipe systems and related
products.
All Model OH nozzles are concealed nozzles to be installed with the nozzle plate flush with the ceiling surface and fit in ø50ø55mm ceiling holes using the Model OH-S36 nozzle spanner. Model OH-rosettes should be utilized as well.
Model OH nozzles are as standard available with the cover-plate finish in Chrome or RAL 9010 but can be supplied in any RAL
colour or metal plating’s on request. Model OH nozzles are all tested and approved to the latest land and maritime standards.
2.1 Automatic Low Pressure Watermist Nozzles type OH.
Nozzle version
OH-L1
Applications Land
Apartments, Atriums, Churches, Concealed spaces,
Gymnasiums, Hospitals, Hotel rooms, Institutions,
Kitchens, Libraries, Meeting rooms in convention,
centers and hotels, Metalworking shops with nonhydraulic cutting operations, Mineral processing such
as: glass, cement, ore treating, gypsum processing, etc.,
Museums, Nursing or convalescent homes, Offices,
Residential areas, Restaurant seating areas, Schools and
universities classrooms, Unused attics and such
applications.
IMO
IMO
FM5560,
DFL80728MSC265(84) MSC265(8
appendix I SW for open
for open
4) for open “light
spaces
spaces up
spaces up
hazard”
designed
to 2.5m
to 5m
according to
ceiling.
ceiling.
TS/CEN
height
Height
14972,
annex B.
Rooms no
larger than
18m2 as hotel
rooms, offices
and such
applications
Halls, corridors, Low ceiling
passages and
inventories, shops and
such
such applications.
applications
IMO
MSC265(84)
for cabins not
larger than 4m
x 4.5m.
IMO
MSC265(84) for
corridors not
wider than
1.5m.
Loyds
Register,
DNV
Loyds Register, Loyds Register,
DNV
DNV
Tested to
Approval
Risk
land
NFPA 13 &
NFPA 750
CEA 4001 /
EN12845 &
CEN/TS14972
FM5560
appendix I &
FM datasheet
no. 3-26
OH-L2
Loyds
Register,
DNV
OH-OS &
OH-VSO
Factory
Mutual
Approved
OH-SW
OH-SWC
DNV Witness
OH-PX1
IMO MSC265(84) for
shopping and storage
areas up to 2.5m
ceiling. height
Loyds Register, DNV
Ordinary Hazard,
group 1 (OH1)**
Light Hazard (LH)*
Light Hazard (LH) & Ordinary Hazard, group 1 (OH1)*
HC-1*
OH-CO
Ordinary Hazard,
group 2 & 3 (OH2 &
OH3)**
HC-2**
*exclusive high rack libraries, facilities with storage of electronics and plastic media, Hospital laboratories, Facilities with operation of
flammable and hydraulic liquids.
**only specific applications.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 6 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2.1.1 Model OH-L1
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-L1
Model OH-L1
Model OH-L1
Pendent
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
13.5 l/min/√bar
Max. 2.5 m.
Max. 4 m., 2 m. to walls
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
DNV TA F-20169, LR MED 1150274 & TA SAS F110370
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Sales and order no:
OHL1-10001
OHL1-10002
OHL1-10003
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
2.1.2 Model OH-L2
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-L2
Model OH-L2
Model OH-L2
Pendent
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
14.5 l/min/√bar
Max. 5 m.
Max. 4 m., 2 m. to walls
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
DNV TA F-20169, LR MED 1150274 & TA SAS F110370
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 7 of 44
Sales and order no:
OHL2-10004
OHL2-10005
OHL2-10006
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2.1.3 Model OH-PX1
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-PX1
Model OH-PX1
Model OH-PX1
Pendent
Brass / stainless steel
NiSn
9-16 bar
< 350μm
23.0 l/min/√bar
Max. 2.5 m
Max. 4 m., 2 m. to walls
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
DNV TA F-20169, LR MED 1150274 & TA SAS F110370
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Sales and order no:
OHPX1-10007
OHPX1-10008
OHPX1-10009
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
2.1.4 Model OH-SWC
Type:
Materials:
Nozzle body finish:
Water pressures:
Dropsize Dv90:
K-factor:
Max. Ceiling height:
Installation height below ceiling:
Nozzle coverage:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-SWC
Model OH-SWC
Model OH-SWC
Side-wall
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
23.0 l/min/√bar
Max. 2.5 m.
0.10 – 0,20 meters
4m x 4.5m, 2m to corners
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
DNV TA F-20169, LR MED 1150274 & TA SAS F110370
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 8 of 44
Sales and order no:
OHSWC-10010
OHSWC-10011
OHSWC-10012
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2.1.5 Model OH-CO
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-CO
Model OH-CO
Model OH-CO
Pendent
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
15.5 l/min/√bar
Max. 2.5 m.
Max. 3m x 1.5m.
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
DNV TA F-20169, LR MED 1150274 & TA SAS F110370
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Sales and order no:
OHCO-10013
OHCO-10014
OHCO-10015
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
2.1.6 Model OH-OS
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-OS
Model OH-OS
Model OH-OS
Pendent
Brass / stainless steel
NiSn
10.5 – 16 bars (tested at 10.5 bar)
< 350μm
16.5 l/min/√bar
Max. 5 m.
Max. 4 m., 2 m. to walls
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
FM Approved FM3041497+3050321
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 9 of 44
Sales and order no:
OHOS-10016
OHOS-10017
OHOS-10018
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2.1.7 Model OH-SW
Type:
Materials:
Nozzle body finish:
Water pressures:
Dropsize Dv90:
K-factor:
Max. Ceiling height:
Installation height below ceiling:
Nozzle coverage:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Product
Model OH-SW
Model OH-SW
Model OH-SW
Side-wall
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
Witnessed by
12.5 l/min/√bar
Max. 2.5 m.
0.10 – 0,20 meters
3.7m x 3.7m, 1.85m to corners
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Sales and order no:
OHSW-10019
OHSW-10020
OHSW-10021
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
Package size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
2.1.8 Model OH-VSO
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle spacing:
Time response index (RTI):
Connection/thread:
Nominal release temperatures:
Approval:
Product
Model OH-VSO
Model OH-VSO
Model OH-VSO
Pendent
Brass / stainless steel
NiSn
8 – 16 bars (tested at 8 bar)
< 350μm
16.7 l/min/√bar
Max. 2.4 m.
Max. 4.5 m., 2.25 m. to walls
Fast response < 45m/√s
½” BSP or ½” NPT
57, 68, 79, 93,141 ºC
FM Approved FM3050321
Variant cover plate
Chrome plated
RAL 9010 (pure white)
Other RAL colour
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 10 of 44
Sales and order no:
OHVSO-10029
OHVSO-10030
OHVSO-10031
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
2.2 Rosettes
2.2.1 Model OH-R rosette for type OH automatic nozzles
The stainless steel rosette forms a fine finish between the semi concealed nozzles and the
ceiling and wall surfaces. The rosette is available in various finishes and RAL colours. The
rosette is screwed on the nozzles by thread connection. Besides the standard version Model
OH-R-T, the rosette also comes in a version (Model OH-R-TH) with four screw holes placed
on the top surface. These can be used to lock the rosette to the ceiling.
Product
Model OH-R-T
Model OH-R-T
Model OH-R-T
Model OH-R-TH
Model OH-R-TH
Model OH-R-TH
Variant cover plate
Stainless steel plating
RAL 9010 (pure white)
Other RAL colours
Stainless steel plating
RAL 9010 “white”
Other RAL colours
Sales and order no:
OHRT-10022
OHRT-10023
OHRT-10024
OHRTH-10026
OHRTH-10027
OHRTH-10028
Package size
30
30
30
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
On request
On request
On request
2.3 Installation Spanners
2.3.1 Model OH-S36 installation nozzle spanner for type OH automatic
nozzles
The OH-S36 is an installation tool for the OH-automatic nozzle series and should be used for
nozzle installations in walls and ceilings.
Product
Model OH-S36
Variant cover plate
Stainless steel plating
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 11 of 44
Sales and order no:
OHS36-10025
Package size
1
Package price DKK/Euro/GBP
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
3. Open Low Pressure Watermist Nozzles and Linear Nozzles for industrial
applications where fluid hydrocarbons are the main risk.
3.1 Open Nozzles
Overview:
Nozzle
name
Applicatio
n
Model K6
Tested to
FM5560
appendix G & H Machinery
spaces & turbine
enclosures.
Factory Mutual
Approval
Approvals
Machinery spaces and turbine enclosures and other such
applications
Model
Model
Model Biscay
Model Tampa
Hudson B1
Bengal B1 N-pipe K1
N-pipe F1
Industrial applications such as machinery spaces and turbine
enclosures, process areas, production areas and more.
IMO
MSC/Circ.
1165 - Full
Flooding
IMO MSC/Circ. 1387 Local Protection
IMO MSC/Circ. 1165 - Bilge Protection.
1% AFFF
after 7min
1% AFFF
Pure watermist
Loyds
Register, DNV
TA+MED
Loyds Register, DNV
TA+MED
DNV MED
DNV MED
DNV TA+MED
DNV TA+MED
3.1.1 Model K6
Model K6 is an open robust water mist nozzles for industrial applications. It has
been Factory Mutual tested and approved to the FM5560 test method for
machinery spaces and turbine enclosures in a volume of 4610m3 and with a ceiling
height of 12m. Further it has been tested to the IMO1165 machinery space tests in
3
volumes up to 5036m with 10m ceiling height.
It has also been tested to the latest revision of IMO1387 (local protection) from
0,75m to 11m above the risk area.
The K6 nozzle is MED and TA approved by Lloyds Register and MED and TA approved
by DNV to the mentioned test methods.
The Model K6 can be delivered with ordinary thread connections
or special M10x1 thread for connection to smart pipe Model N-pipes.
Approval FM:
Approval Local Protection:
Approval Full Flooding:
Type:
Materials:
Nozzle body finish:
Connection/thread:
Dropsize Dv90:
K-factor:
Water pressures:
Maximum enclosure height:
Maximum enclosure volume:
Maximum nozzle spacing:
N-pipe fit:
Spray angle:
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 12 of 44
FM Approved FM3040609
DNV TA F-20168, LR MED 1150272 & TA SAS F110368
DNV MED-B-9565 & TA F-20178, LR MED 1150271 & TA SAS F110367
Pendent installation
Naval Brass, stainless steel 316, titanium grade 2.
NiSn
½” BSP-T, ½” NPT, M10x1mm
< 350μm
5.6 l/min/√bar
FM5560
IMO1387
IMO1165(A)
7.7 – 16 bars
7.7 bar
12.5 bar
9 bar.
12m
12m
0.75-11m
10m
5036 m3
4610m3
NA.
5036m3
3m x 3m (1.5m to walls.)
3m x 3m
1.5m x 1.5m
3m x 3m
N-pipe type FF and type LP
Type FF
Type LP
Type FF
95 º
IMO1165(B)
8 bar
10m
3842m3
3m x 3m
Type FF
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
Variant
Sales and order no:
Model K6
Model K6
Model K6
Material: Brass + NiSn
Material: Stainless steel 316L
Material: Titanium Grade 2
K6-10100
K6-10101
K6-10102
Package
size
30
30
30
Package price DKK/Euro/GBP
On request
On request
On request
3.1.2 N-pipes for Model K6 nozzle
N-pipes are designed to save installation cost, time,
and to reduce the risk of getting impurities into the
system. N-pipes are 6m length stainless steel pipes
with premade installation holes in the pipes according
to the spacing of the different nozzle configurations.
For Full Flooding Systems the N-pipes should be ordered as Type FF, and for Local Protection systems they should be ordered as
Type LP.
- For Type FF they come with two premade installation holes placed 3m apart and with 1.5m to each end. This ensures the
spacing of 3m between all nozzles when more pipes are connected.
- For Type LP they come with four premade installation holes placed 1.5m apart and with 0.75m to each end. This ensures the
spacing of 1.5m between all nozzles when more pipes are connected.
N-Pipes are installed for fire protection of process areas, machinery spaces, around turbines and other areas where
simultaneous activation of multiple nozzles are required. N-pipes can be supplied with connections as specified by the cutomer.
General info:
Normal application:
Materials:
Connection/thread:
Water pressures:
Length:
Pipe size:
N-pipe types:
Full Flooding systems and Local Protection system
Stainless steel 316
Open ends for press fitting connection or ¾” BSP male and female threaded ends.
Maximum 16 bar.
6m
25mm, 28mm and 35mm. Other sizes can be supplied on request.
Type LP, Type FF.
Attention: The price below is exclusive nozzles.
Product:
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
type:
LP-25
FF-25
LP-28
FF-28
LP-35
FF-35
LP-S
FF-S
N-pipe size
25mm with ¾” male+female ends
25mm with ¾” male+female ends
28mm with open ends for press f.
28mm with open ends for press f.
35mm with open ends for press f.
35mm with open ends for press f.
Other sizes
Other sizes
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 13 of 44
Sales and order
no:
K6-Npipe-10103
K6-Npipe-10104
K6-Npipe-10105
K6-Npipe-10106
K6-Npipe-10107
K6-Npipe-10108
K6-Npipe-10109
K6-Npipe-10110
Package
size
1 x 6m
1 x 6m
1 x 6m
1 x 6m
1 x 6m
1 x 6m
1 x 6m
1 x 6m
Package price DKK/Euro/GBP
On request
On request
On request
On request
On request
On request
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
3.1.3 Hudson & Bengal Type B1 - open full cone low pressure water mist nozzles.
Type Hudson & Bengal B1 open full cone water mist nozzles are robust small dimension nozzles for bilge protection and other
such industrial applications. It has been tested and approved to the IMO 1165 bilge test.
Type:
Normal application:
Materials:
Nozzle body finish:
Connection/thread:
Water pressures:
Dropsize Dv90:
K-factor:
Installation height:
Bilge height (max.):
Nozzle coverage:
Spray angle:
Approval Full Flooding:
Horizontal installation
Bilge Protection
Brass, stainless steel 316
NiSn
3/8” BSP
10.5 – 16 bars (tested at 10.5 bar)
< 350μm
2.8 l/min/√bar
0.30 – 0.60 meters
1.1 m
1.5m x 4.0m
95 º
DNV MED-B-9565
Product
Variant
Sales and order no:
Type B1
Type B1
Type B1
Material: Naval Brass + NiSn
Material: Stainless steel 316
Material: Titanium Grade 2
Hud/Ben-B1-10111
Hud/Ben-B1-10112
Hud/Ben-B1-10113
Package
size
30
30
50
Package price DKK/Euro/GBP
On request
On request
On request
3.1.4 Biscay Type N-pipe K1
Type Biscay N-pipe K1 are 6 meter length stainless steel 316L
pipes with small robust nozzles integrated in the pipes. On one
6m pipe 24 nozzles are installed, 2 nozzles per 0.5meter. Every
pair are positioned with 180 degree between them and in
function they will spray watermist to both sides of the pipe. The
pipes are installed in parallel lines with 1.7meter between them
and throughout the full length of the area. The system has been
tested and approved to the IMO 1165 bilge test without use of
any foam enhancements. The Biscay type N-pipe K1 can be
supplied in pipes sizes and with pipe ends in accordance to
customer requirements.
As option the Type Biscay can be supplied in a special one spray version for installations which require only
protection on one side of the pipe.
Type:
Normal application:
Pipe size:
Materials pipes:
Materials nozzles:
Nozzle type:
Connection/thread:
Water pressures:
Spray angle:
Approvals:
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 14 of 44
Horizontal installation
Bilge Protection
Ø 28mm.
Stainless steel 316L
Brass + NiSn / SS 303
K1 with M10 x 1mm connection
Open end for press fittings.
11 – 16 bars (tested at 11 bars)
95 º
DNV MED-B-9565 & TA F-20178
Dropsize DN90:
K-factor per 6m pipe:
K-factor per nozzle:
Installation height:
Bilge height (max.):
Nozzle spacing on pipes:
N-pipe spacing parallel:
6m pipe coverage:
Nozzles per 6m:
< 300 μm
21.6 l/min/√bar
0.9 l/min/√bar
0.37 – 0.45 m
0.75 m
0.5 m x 1.7 m
Max. 1.7 m
6m x 1.7m
24 nozzles, type K1
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
Pipe type
Variant
Biscay type
N-pipe K1
28mm with open ends
Biscay type
N-pipe K1
25mm with ¾” male+female
ends
Biscay type
N-pipe K1
Biscay type
N-pipe K1
Other pipe sizes
2sidespraypresspipe28m
m, 6m
2sidespraythreadpipe25
mm, 6m
Special types
Biscay type
N-pipe K1
25x1.2mm with ¾”
male+female ends
Spares
K1 nozzle
NA.
28x1.2mm with open ends
for press fittings
1sidespraypresspipe28m
m, 6m
1sidespraythreadpipe25
mm, 6m
Spare nozzle
Model K1
Sales and
order no:
Biscay-K110114
Package size
1 x 6m + 24 nozzle
Package price
DKK/Euro/GBP
On request
Biscay-K110115
1 x 6m + 24 nozzle
On request
Biscay-K110116
Biscay-K110123
1 x 6m + 24 nozzle
On request
1 x 6m + 12 nozzle
On request
Biscay-K110124
1 x 6m + 12 nozzle
On request
Biscay-K110125
24
On request
3.1.5 Tampa Type N-pipe F1
Type Tampa N-pipe F1 are 6 meter length stainless steel 316L pipes
with small robust nozzles integrated in the pipes. On one 6m pipe 16
nozzles are installed, 2 nozzles per 0.75meter. Every pair are
positioned with 180 degree between them and in function they will
spray watermist to both sides of the pipe. The pipes are installed in
parallel lines with 1.75meter between them and throughout the full
length of the area. The system has been tested and approved to the
IMO 1165 bilge test without use of any foam enhancements. The
Tampa type N-pipe F1 can be supplied in pipes sizes and with pipe
ends in accordance to customer requirements.
As option the Type Tampa can be supplied in a special one spray
version for installations which require only protection on one side of the pipe.
Type:
Normal application:
Pipe size:
Materials pipes:
Materials nozzles:
Nozzle type:
Connection/thread:
Water pressures:
Spray angle:
Approvals:
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 15 of 44
Horizontal installation
Bilge Protection
Ø 28mm.
Stainless steel 316L
Brass + NiSn / SS 303
F1 with M10 x 1mm connection
Open end for press fittings.
11 – 16 bars (tested at 11 bars)
95 º
DNV MED-B-9565 & TA F-20178
Dropsize DN90:
K-factor per 6m pipe:
K-factor per nozzle:
Installation height:
Bilge height (max.):
Nozzle spacing on pipes:
N-pipe spacing parallel:
6m pipe coverage:
Nozzles per 6m:
< 300 μm
17.6 l/min/√bar
1.1 l/min/√bar
0.35 – 0.37 m
1.10 m
0.75 m
Max. 1.75 m
6m x 1.75m
16 nozzles, type F1
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
Pipe type
Variant
Tampa type
N-pipe F1
28mm with open ends
Tampa type
N-pipe F1
25mm with ¾” male+female
ends
Tampa type
N-pipe F1
Tampa type
N-pipe F1
Other pipe sizes
2sidespraypresspipe28m
m, 6m
2sidespraythreadpipe25
mm, 6m
Special types
Tampa type
N-pipe F1
25x1.2mm
with
male+female ends
Spares
F1 nozzle
NA.
28x1.2mm with open ends
for press fittings
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 16 of 44
¾”
1sidespraypresspipe28m
m, 6m
1sidespraythreadpipe25
mm, 6m
Spare nozzle
Model F1
Sales and
order no:
Tampa-F110117
Package size
1 x 6m + 16 nozzle
Package price
DKK/Euro/GBP
On request
Tampa-F110118
1 x 6m + 16 nozzle
On request
Tampa-F110119
Tampa-F110120
To be defined
On request
1 x 6m + 8 nozzle
On request
Tampa-F110121
1 x 6m + 8 nozzle
On request
Tampa-F110122
24
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4. Nozzles and Systems for defined applications.
4.1 Atriums, aulas, halls, lobbies, etc.
4.2 Commercial and industrial fryers, and ventilation ducts
4.3 Residential homes, institutions, elderly people homes, etc.
4.4 Inventories, conveyor belts, rack storages, etc.
4.5 Military, air force, navy
4.6 Road tunnels, rail, tunnels, metro tunnels, cable tunnels, etc.
4.7 Rolling stock, train wagons, metro wagons
4.8 Underground Car parks and garages.
4.1 Application: Atriums, aulas, halls, multiple seating areas etc.
Application:
System model
System type
Atriums, aulas, halls, lobbies, multiple seating areas etc.
Model APS
Model AU7
Horizontally installed system
Pop-up nozzles
4.1.1 Model APS – Atrium/hall protection system
VID Fire-Kill Atrium Fire Protection Systems Model APS are developed for fixed installed fire protection of atriums and other
similar locations without maximum limitations to heights and lengths of the rooms. Atrium locations are defined as tall indoor
areas with a large floor area, and a low fire load per area.
The Model APS system is installed on the atrium walls and provides firefighting with a horizontal water mist spray from the
walls. The system consists of 6m stainless small steel pipes with premade connection-threads for installation of small open
nozzles directly into the pipes. Optional the nozzles can be installed on the walls with the pipe installed behind. Here the
extension kit should be used. Nozzle type and configuration is specially designed to cover different size atriums. Connections to
the pipe can either be 28mm open ends prepared for press fittings, or they can be supplied with ¾” BSP/NPT, male/female
threads.
Type:
Pipe materials:
Pipe size:
Pipe threads on ends:
Nozzle material + finish:
Thread on nozzles:
Nozzles per 6 meter pipe:
Dropsize Dv90:
Installation height:
Water pressures:
Coverage area into room
K-factor per 6m pipe:
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 17 of 44
Horizontal installation
Stainless steel 316,
Thread end type: 25x1.2mm
Open end type: 28x1.2mm
¾” BSP or NPT, male or female.
Open ends prepared for press fitting connection.
Brass + NiSn
M8x1mm
6 pcs.
< 350μm
3 – 7 meter
Type A
Type B
6 – 16 bars
6 bar
6 bar
5 – 13 meter
8m
10m
26-62
37
52
Type C
10 bar.
13m
62
Type D
6 bar
5m
26
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
Variant
Model APS
Type A, Open ends for press fittings.
Model APS
Type A, Thread connections (Must be
specified)
Type B, Open ends for press fittings.
APS-10201
Type B, Thread connections (Must be
specified)
Type C, Open ends for press fittings.
APS-10203
Type C, Thread connections (Must be
specified)
Type D, Open ends for press fittings.
APS-10205
Type D, Thread connections (Must be
specified)
Special types
APS-10207
Model APS
Model APS
Model APS
Model APS
Model APS
Model APS
Model APS
Extra Options
Spare nozzles
Nozzles extension fitting kit straight <0.5m
Nozzles extension fitting kit –
angle <0.5m
RAL Color on nozzle
Sales
and
order no:
APS-10200
Package size
Package price DKK/Euro/GBP
APS-10311
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
6m pipe +
nozzles
To be defined
NA.
NA.
APS-10208
APS-10209
6 nozzles
6 sets
On request
On request
NA.
APS-10312
6 sets
On request
NA.
APS-10313
6 sets
On request
APS-10202
APS-10204
APS-10206
6
On request
6
On request
6
On request
6
On request
6
On request
6
On request
6
On request
6
On request
On request
4.1.2 Model AU7 – Watermist nozzle for protection of concert halls and
other multiple seated areas
The nozzles are designed for active fire fighting in large indoor spaces with high ceiling
heights, which contains moderate fire loads. Typical applications are concert halls,
cinemas, auditoriums, atriums and lobbies.
Type:
Normal application:
Materials:
Connection/thread:
Water pressures:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle coverage:
Spray height:
Product
Model AU7
Variant
Full assembly
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 18 of 44
Imbedded nozzle
Multiple seated areas.
Brass + NiSn
¾” BSP male.
8 – 16 bars
< 350μm
7 l/min/√bar
Imbedded in floor or furniture.
1m x 9m
5.5-6m
Sales and order no:
AU7-10210
Package size
30
Package price DKK/Euro/GBP
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.2 Application: Commercial and industrial fryers, and ducts
Application:
System model
System type
Commercial and industrial fryers, and ducts
Model DFI-1
Model Vesuvius
Model Etna
Stand-alone unit for
Pipe and nozzle
Pipe and nozzle
small commercial fryer system
system
<25l commercial fat
<25l commercial
Ducts.
fryers
fat fryers, and
<150l industrial fat
fryers.
Specific application
4.2.1 Model DFI-1 – Small standalone system for commercial fat fryer system
VID Fire-Kill develops and manufactures micro systems such as the model DFI-1 for protection of commercial fat fryer pools in
fast food restaurants, commercial kitchens, restaurants and cafes. DFI-1 is a small self-contained fire protection system with
both automatic and manual release, that is tested and approved by DNV (Det Norske Veritas) in accordance with the European
Norm EN 3-7:2004+A1:2007, class 25F, for protection of fat fryers up to 25 litres. The system is delivered fully assembled and
ready for fixed installation. In case of fire the system automatically sends a signal and turns off the heat to the fryer pool at the
same time activating a spray of extinguishing agent to suppress and extinguish the fire in a calm and controlled way without any
splashing from the fryer pool. The aerosol canisters should be replaced with new every two year.
Installation height above application:
Outputs:
Spray angle:
Spray Duration time:
Max. temperature on aerosol canister and control unit:
Replacement of canisters:
0,6m – 1,2m.
Normally Closed or Normally Open
60º.
10-20 sec
50ºC.
nd
Every 2 year
Product
Variant
DFI-1
A500 - Complete system incl.
12VDC-230VAC power supply
Extra options and spares
Power supply 12 Vdc 2 amp
Box w. Power 24h back-up
12Vdc & audio alarm
BOX w. power 24h back-up &
12Vdc & audio alarm & SMS
Alarm
A500 kitchen Aerosol cylinder
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 19 of 44
Sales and order
no:
DFI1-10211
Package
size
1
Package price
DKK/Euro/GBP
On request
For all systems
For all systems
DFI1-10212
DFI1-10213
1
1
On request
On request
For all systems
DFI1-10214
1
On request
For vertical and horizontal
installation (2 years lifetime)
DFI1-10215
1
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.2.2 Model Vesuvius N-pipe Type 2V-BM1 – Linear Nozzle for commercial and industrial fat fryers.
The VID Fire-Kill Model Vesuvius N-pipe Type 2V-BM1
Water Mist System is a linear nozzle with the length of
1.8m and is designed to fight fat fryer fires with pure
water. The system is installed in the kitchen hood as
close to the centerline as possible and covers up to
0.75m on each side of the centerline and a length of
1.8m. If more coverage area is needed, the system can
be connected in the ends to give a coverage area of
(no. of system x 1.8m x 1.5m. If the hood is wider than 1.5m
more strings of the N-pipe system should be installed parallel
with a maximum spacing of 1.5m. The system should in any case
be installed between 1m - 1.5m above the fat fryer surface.
The system is fast and simple to install and requires the use of a minimum of pipe fittings. The system is delivered in 1.8 meter
N-pipe lengths with pre-made threaded connections for VID Fire-Kill BM1 water mist micro nozzles. The nozzles are installed in
pairs of two with each pair position with 60° between them (30° from the vertical centerline) and with a spacing of 0.6m
between the pair of nozzles on the pipe. A total of six BM1 nozzles are used per 1.8m N-Pipe.
N-Pipes are available in ø25 x 1,2mm with ¾” BSP male/female end connections, and Ø28 x 1,2mm for connections with pressfittings.
Optional Plastic or Metal protection caps for BM-1 micro nozzles are available.
The system has successfully been fire tested to ISO 15371 fire test standard for water mist systems for fire protection of fat
fryers up to 25l, conducted by The Danish Fire Laboratories (DFL) and approved by DNV for MED and Type approval.
Further the system has been full scale fire tested in industrial fat fryer with surface areas up to 3m2 with 150l oil in the fryer.
Type:
Normal application:
Pipe size:
Materials pipes:
Materials nozzles:
Nozzles per 6m:
Nozzle type:
Connection/thread:
Water pressures:
Spray angle:
Product
Vesuvius
2V-BM1
N-pipe
Horizontal installation
Commercial & industrial fryers
Ø 28mm.
Stainless steel 316L
Stainless steel 316L
6 nozzles
BM-1-28
Open end for press fittings
7 – 9 bars
95 º
Pipe type
Variant
28mm with open ends
Type
VesuviusPR
Type
Vesuvius
Type
Vesuvius-S
Vesuvius N-pipe 25mm
with
2V-BM1
male+female ends
Vesuvius N-pipe Other pipe sizes
2V-BM1
Options
Plastic protection cap
Stainless steel protection cap with chain.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 20 of 44
¾”
NA.
NA.
Dropsize DN90:
< 300 μm
K-factor per 1.8m pipe:
16.8 l/min/√bar
K-factor per nozzle:
2.8 l/min/√bar
Installation height above fryer: 1.00m – 1.50 m
Fryer size (max.):
25l
Fryer surface (max.):
0.45m x 0.48m
Nozzle spacing on pipes:
0.6 m
N-pipe spacing parallel:
Max. 1.5 m
1.8m pipe coverage:
1.8m x 1.5m
Approvals:
DNV MED-B-7981 & TA F-20213
Sales and
order no:
Vesuvius10216
Package size
Package price DKK/Euro/GBP
1 x 1.8m + 6
nozzle
On request
Vesuvius10217
Vesuvius10218
1 x 1.8m + 6
nozzle
1 x 1.8m + 6
nozzle
On request
Vesuvius10314
Vesuvius10315
6 caps
On request
6 caps + chain
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.2.3 Model Etna N-pipe Type I-K1 – Linear Nozzle for commercial and industrial ventilation ducts.
The VID Fire-Kill Model Etna N-pipe Type I-K1 Water Mist
System is a linear nozzle with the length of 6m and is
designed to fights duct fires with pure water. The system is
installed in extraction ducts as close to one of the upper
corners for square ducts, and as close the upper sides in
round ducts as possible. The system will cover the whole duct volume
in a 6 meter duct. To cover longer ducts more systems are connected
to each other. The system has been tested and approved to cover any
length duct when installed throughout the duct and with duct cross
sections up to 0.3m x 0.6m for square ducts and a duct cross section
up to 0.57m in diameter for round ducts.
The system is fast and simple to install and requires the use of a
minimum of pipe fittings. The system is delivered in 6 meter N-pipe lengths with pre-made threaded connections for VID Fire-Kill
K1 water mist micro nozzles. The nozzles are installed with a spacing of 0.5m between each nozzle on the pipe. A total of 12 K1
micro nozzles are used per 6m N-Pipe.
N-Pipes are available in ø25 x 1,2mm with ¾” BSP male/female end connections, and Ø28 x 1,2mm for connections with pressfittings.
Optional Plastic or Metal protection caps for K1 micro nozzles are available. Extension nozzle kits are also available for
installation of the N-pipe outside the duct, and the nozzles inside the duct.
The system has successfully been fire tested to ISO 15371 fire test standard for water mist systems for fire protection of duct
conducted by The Danish Fire Laboratories (DFL) and approved by DNV for MED and Type approval.
Type:
Normal application:
Pipe size:
Materials pipes:
Materials nozzles:
Nozzle type:
Connection/thread:
Water pressures:
Spray angle:
Product
Horizontal installation
Ventilation Ducts
Ø 28mm.
Stainless steel 316L
SS 303
K1 with M10 x 1mm connection
Open end for press fittings.
6 – 16 bars (tested at 6 bars)
95 º
Pipe type
Etna type N- 28mm with open ends
pipe I-K1
Etna type N- 25mm with ¾” male+female
pipe I-K1
ends
Etna type N- Other pipe sizes
pipe I-K1
Options
K1-Extensionkit
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 21 of 44
Variant
Type EtnaPR
Type Etna
Type Etna-S
NA.
Dropsize DN90:
K-factor per 6m pipe:
K-factor per nozzle:
Duct cross section (max):
Duct length (max.):
Nozzle spacing on pipes:
Nozzles per 6m:
6m pipe coverage area
Approvals:
Sales and
order no:
Etna10219
Etna10220
Etna10221
Package size
Etna10316
< 300 μm
10.8 l/min/√bar
0.9 l/min/√bar
0.6m x 0.3m
NA.
0.50 m
12 nozzles, type K1
6m x 0.6m
DNV TA F-20213
1 x 6m + 12 nozzle
Package price
DKK/Euro/GBP
On request
1 x 6m + 12 nozzle
On request
Other lengths.
On request
12 pcs
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.3 Application: Residential homes, institutions, elderly people homes, etc
Application:
System model
System type
Residential homes, institutions, elderly people homes, etc
Model BB
Model BBK
Modular retrofit system
Object protect
4.3.1 Model BB – Fire suppression and life safety in residential areas.
The VID Model BB is designed for fast and simple protection of people’s lives in case of fire in private homes or institutions. The
system is easy to install and has a discrete design, and is designed to be installed in existing buildings.
The Model BB system consists of five main parts.
 A control unit which can operate up to 6 zone valves and six smoke detectors.
 Zone valves.
 Smoke detectors.
 Wall panels with water supply pipes and nozzles pipes integrated.
 A water supply unit.
The BB module panels are connected to 2.5 bar – 3.0 bars water pressure, which are common in most domestic water-supplies,
and the BB control unit is connected to the domestic power supply.
In case of fire the, smoke activates the smoke detector, and the heat of fire creates a rise of heat in the room. The rise of heat is
detected by the thermo sensor located closest to the fire. When both smoke and rise of heat is detected, the system
automatically activates a potential free alarm switch. The wall panels do hereafter distribute water onto the area from the
activated valve wall module and from the closest valve modules on both sides of the first activated valve wall module.
Valve modules have as additional safety also glass bulb activation, which will operate the system should power of any reason
fail. After system activation, the activated valve module should be replaced with a new one. Alarms may be provided from
computer LAN connection, by telephone SMS service or from traditional alarm circuits and modems. Rise of heat level and time
delays are customized to match the location by help of software and a computer / PC.
All valve and module panels can be supplied in any RAL colour. If not specified the colour will be white RAL9010.
The system can be supplied in loose parts as specified below, or can be designed to fit and actual application. Special designs can
be made by request to the sales department.
Product
Main parts
Basic control unit for 6 valve module incl. 48h power
back-up
Basic control unit + text and modem alarm output.
Smoke detector with socket and 10m flying wire with
plug.
Water
supply
module
with
¾”
BSP
connections(Electrical monitored stop valve w. lock,
strainer, non-return valve, pressure switch, drain tee)
10 m. wire kit for 6 zone valves.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 22 of 44
Sales and order no:
Package
size
Package price DKK/Euro/GBP
BB-10222
1
On request
BB-10230
BB-10223
1
1
On request
On request
BB-10224
1
On request
BB-10225
1
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Additions
USP Connector module
Software package
Zone valves
Valve unit
Nozzle panels with supply, nozzle pipes, nozzles and
wall hanger brackets
Panel: L= 0-500mm , 1x Nozzle , 2 x brackets
Panel: L= 501-1000mm , 1x Nozzle , 2 x brackets
Panel: L= 501-1000mm , 2x Nozzle , 2 x brackets
Panel: L = 1001-1500mm, 2 x Nozzles, 2 x brackets
Panel: L = 1001-1500mm, 3 x Nozzles, 2 x brackets
Panel: L = 1501-2000mm, 2 x Nozzle, 3 x brackets
Panel: L = 1501-2000mm, 3 x Nozzle, 3 x brackets
Nozzle panels without supply pipe, but with nozzle
pipes, nozzles and wall hanger brackets.
Panel: L= 0-500mm , 1x Nozzle , 2 x brackets
Panel: L= 501-1000mm , 1x Nozzle , 2 x brackets
Panel: L= 501-1000mm , 2x Nozzle , 2 x brackets
Panel: L = 1001-1500mm, 2 x Nozzles, 2 x brackets
Panel: L = 1001-1500mm, 3 x Nozzles, 2 x brackets
Panel: L = 1501-2000mm, 2 x Nozzle, 3 x brackets
Panel: L = 1501-2000mm, 3 x Nozzle, 3 x brackets
Panels with supply pipes, without nozzle pipes, but
with wall hanger brackets.
Panel: L= 0-500mm, 2 x brackets
Panel: L= 501-1000mm, 2 x brackets
Panel: L= 501-1000mm , 2 x brackets
Panel: L = 1001-1500mm, 2 x brackets
Panel: L = 1001-1500mm, 2 x brackets
Panel: L = 1501-2000mm, 3 x brackets
Panel: L = 1501-2000mm, 3 x brackets
Corner Panels 90º
For inner corners: Inside corner panel w. supply pipe, w.
nozzle pipe L: 2 x 150mm
For outer corners: Outside corner panel w. supply pipe,
w. nozzle pipe L: 2x 150mm
Cover Panels
Cover panel 200mm white RAL (to cover panel joints)
Panel end cover plate 200mm white RAL – Right version
(to finish ends of panel assemblies)
Panel end cover plate 200mm white RAL – Left version
(to finish ends of panel assemblies)
Special Panels
Tee panel 200mm - white RAL
Through wall corner panel 200mm - white RAL
¾”BSP male Water supply connection
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 23 of 44
BB-10226
BB-10227
1
1
On request
On request
BB-10228
1
On request
BB-10231
BB-10232
BB-10233
BB-10234
BB-10235
BB-10236
BB-10237
1
1
1
1
1
1
1
On request
On request
On request
On request
On request
On request
On request
BB-10244
BB-10245
BB-10246
BB-10247
BB-10248
BB-10249
BB-10250
1
1
1
1
1
1
1
On request
On request
On request
On request
On request
On request
On request
BB-10257
BB-10258
BB-10259
BB-10260
BB-10261
BB-10262
BB-10263
1
1
1
1
1
1
1
On request
On request
On request
On request
On request
On request
On request
BB-10269
1
On request
BB-10270
1
On request
BB-10272
BB-10273
1
1
On request
On request
BB-10271
1
On request
BB-10274
BB-10275
BB-10265
1
1
1
On request
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.3.2 Model BBK – Local fire suppression and life safety in residential areas.
The VID Model BBK is designed for fast and simple local protection of people’s lives in case of fire in private homes or
institutions. The system is easy to install and has a discrete design, and is designed to be installed in existing buildings.
The Model BBK operates on 2.5 bar – 3.0 bars water pressure, which are common in most domestic water-supplies, and the BBK
integrated detection system is connected to the domestic power supply.
The BBK consists of a metal panel which has a simple detection system integrated as well as a valve and 3 small watermist
nozzles designed to fight fires in a local area. The Model BBK can be supplied in 3 lengths; 1.9m, 2.6m, 3.3m. Each length is
designed to cover an area, which also depends on the water pressure:
2.5 bar
1.9m: 2.1m x 2m
2.6m: 2.8m x 2m
3.3m: 3.5m x 2m
3bar
2.1m x 3m
2.8m x 3m
3.5m x 3m
In case of fire the heat of fire creates a rise of heat in the room. The rise of heat is detected by the thermo sensor integrated in
the panel. In case the rise of heat is higher than the preset value, the system automatically activates the valve and does also
send an alarm signal through a potential free alarm switch. As the valve opens, water is distributed to the nozzles and hereafter
the nozzles distribute fine watermist onto the area. After system activation, the activated valve module should be replaced with
a new one.
The Model BBK can be supplied in any RAL colour. If not specified the colour will be white RAL9010.
Product
Variant
Sales and order no:
Package size
Model BBK
Panel length: 1.9m. Includes 3 nozzle, 3
wall brackets
Panel length: 2.6m Includes 4 nozzle, 4
wall brackets
Panel length: 3.3m Includes 5 nozzle, 5
wall brackets
BBK-10276
1
Package
DKK/Euro/GBP
On request
BBK-10277
1
On request
BBK-10278
1
On request
For Model BBK only
BBK-10279
1
On request
Model BBK
Model BBK
Spares
Valve unit
4.4 Application: Inventories, rack storages, Conveyor belts, attics, subfloor etc.
Application:
System model
System type
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 24 of 44
Inventories, conveyor belts,
attics, subfloor
Model N-pipe with BM-1 nozzles
Pipe and nozzle system
Rack storages
Model RS
Pipe, nozzle, valve system
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
price
Catalogue2015
4.4.1 N-pipes with BM-1, K1 or F1 nozzles – Protection of class A+B fire risks.
In general N-Pipes are utilized in low pressure water mist installations, where the use of N-pipes represents significant
reductions in installation costs. N-Pipes are installed for fire protection of inventories, process areas, machinery spaces,
storages, cable tunnels and other local applications like below escalators, around turbines and other areas where simultaneous
activation of multiple nozzles are required.
N-pipes integrate small BM-1, K1 or F1 nozzles in different configurations in the pipe, as to suit the individual application. We
offer three standard solutions:
- Type I: Is designed with six BM-1 nozzles installed in the N-pipe in a straight row with 1m between each nozzle and 0.5m to
both pipe ends. Type I are used for protection of narrow areas not exceeding 1.5m such as conveyor belt, path ways etc.
- Type 2V: Is designed with 12 BM-1 nozzles installed in pairs with each nozzle pair separated with an angle of 90 degrees, and
having 1m between each nozzle pair and 0.5m to ends. Type 2V is typical used in OH 2/3 areas for protection of class A
fires, and can be installed up to 10-12m above fuel surface.
- Type 3V: Is designed with 18 BM-1 nozzles installed in pairs of three with each nozzle separated with an angle of 45 degrees,
and having every three nozzles separated with 1m between them on the pipes. Type 3V is only used for special category
risks where a lot of water is needed locally.
N-pipes with BM-1, K1 or F1 nozzles has been full scale tested and installed in many different applications, so it is advised to take
contact to our sales department for more advise on how best to utilize N-pipes.
N-pipes are delivered either in 25mm SS316 pipes with ¾” thread connections or 28mm, 35mm, 42mm, 54mm or 76.1mm
SS316 press pipes with open ends prepared for press fittings. Other pipe sizes can be supplied on request.
General info N-pipes:
Normal application:
Materials:
Connection/thread:
Water pressures:
Length:
Pipe size:
N-pipe types:
Industrial class A fire applications
Stainless steel 316L
¾” BSP male/female or open ends for press fitting connection.
Maximum 16 bar.
6m
25, 28, 35, 42, 54 & 76.1 mm. Other sizes can be supplied on request.
Type I, Type 2V, Type 3V.
Attention: N-pipes and nozzles are purchased separately.
Product
Pipe type
Variant
N-pipe
28x1.2mm with open ends for
press fittings
28x1.2mm with open ends for
press fittings
28x1.2mm with open ends for
press fittings
35x1.5mm with open ends for
press fittings
35x1.5mm with open ends for
press fittings
35x1.5mm with open ends for
press fittings
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 25 of 44
Type I-PR28
Sales
and
order no:
Npipe-10280
Package
size
1 x 6m
Package price
DKK/Euro/GBP
On request
Type 2V-PR28
Npipe-10281
1 x 6m
On request
Type 3V-PR28
Npipe-10282
1 x 6m
On request
Type I-PR35
Npipe-10283
1 x 6m
On request
Type 2V-PR35
Npipe-10284
1 x 6m
On request
Type 3V-PR35
Npipe-10285
1 x 6m
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
N-pipe
25x1.2mm with ¾” male+female
ends
25x1.2mm with ¾” male+female
ends
25x1.2mm with ¾” male+female
ends
42x1.5mm with open ends for
press fittings
42x1.5mm with open ends for
press fittings
42x1.5mm with open ends for
press fittings
54x1.5mm with open ends for
press fittings
54x1.5mm with open ends for
press fittings
54x1.5mm with open ends for
press fittings
76.1x2mm with open ends for
press fittings
76.1x2mm with open ends for
press fittings
76.1x2mm with open ends for
press fittings
On request
Type I-TR25
Npipe-10286
1 x 6m
On request
Type 2V-TR25
Npipe-10287
1 x 6m
On request
Type 3V-TR25
Npipe-10288
1 x 6m
On request
Type I-PR42
Npipe-10318
1 x 6m
On request
Type 2V-PR42
Npipe-10319
1 x 6m
On request
Type 3V-PR42
Npipe-10320
1 x 6m
On request
Type I-PR54
Npipe-10321
1 x 6m
On request
Type 2V-PR54
Npipe-10322
1 x 6m
On request
Type 3V-PR54
Npipe-10323
1 x 6m
On request
Type I-PR76
Npipe-10324
1 x 6m
On request
Type 2V-PR76
Npipe-10325
1 x 6m
On request
Type 3V-PR76
Npipe-10326
1 x 6m
On request
Special
Npipe-10227
On
request
On request
BM-1 nozzle
Type BM-1 is an open full cone water mist nozzle which is a robust, small dimension nozzle. The BM-1 nozzles are designed with
special M10x1mm thread for installation in N-pipes.
Type:
Normal application:
Materials:
Nozzle body finish:
K-factor (metric)
Connection/thread:
Water pressures:
Dropsize Dv90:
N-pipe fit:
Installation height:
Nozzle coverage:
BM-1
Industrial applications
Brass / stainless steel
NiSn
1.6, 2.4, 2.8, 3.6
M10x1mm
4 – 16 bars depending on application.
< 350μm
N-pipe Type I, Type 2V, Type 3V
Depending on application.
Depending on application.
Attention: N-pipes and nozzles are purchased separately.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 26 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
BM-1-16
BM-1-24
BM-1-28
BM-1-36
BM-1-16-SS
BM-1-24-SS
BM-1-28-SS
BM-1-36-SS
Variant
K: 1,6 l/min/√bar, SS303+304
K: 2,4 l/min/√bar, SS303+304
K: 2,8 l/min/√bar, SS303+304
K: 3,6 l/min/√bar, SS303+304
K: 1,6 l/min/√bar, SS316.
K: 2,4 l/min/√bar, SS316.
K: 2,8 l/min/√bar, SS316.
K: 3,6 l/min/√bar, SS316.
Sales and order no:
BM1-10290
BM1-10291
BM1-10292
BM1-10293
BM1-10294
BM1-10295
BM1-10296
BM1-10297
Package size
6
6
6
6
6
6
6
6
Package price DKK/Euro/GBP
On request
On request
On request
On request
On request
On request
On request
On request
K1 and F1 nozzle
20.25 mm
M10
7.5 mm
mm
6 mm
K1 & F1
Industrial applications
Stainless steel 304
0.9
1.1
M10x1mm
4 – 16 bars depending on application.
< 350μm
N-pipe Type I, Type 2V, Type 3V
Depending on application.
Depending on application.
6 mm
20.25 mm
M10
7.5 mm
mm
13
Type:
Normal application:
Materials:
K1 K-factor (metric):
F1 K-factor (metric):
Connection/thread:
Water pressures:
Dropsize Dv90:
N-pipe fit:
Installation height:
Nozzle coverage:
13
Type K1 and F1 nozzles are open full cone water mist nozzles which is a robust, small
dimension nozzle. The nozzles are designed with special M10x1mm thread for
installation in N-pipes.
Attention: N-pipes and nozzles are purchased separately.
Product
Type K1
Type F1
Variant
K: 0.9 l/min/√bar, SS304
K: 1.1 l/min/√bar, SS304
Sales and order no:
K1-10328
F1-10329
Package size
6
6
Package price DKK/Euro/GBP
On request
On request
4.4.2 Model RS – protection of racks in inventories.
Model RS-Systems are designed to provide automatic fire detection and suppression in rack storages with requirements to low
fire and water damages in the case of fire in rack storages with low water supply capacities .
The system consists of the following components two main parts. Stainless steel pipes with integrated low pressure watermist
nozzles, and zones valves which are operated by heat.
The idea behind the design is that all spaces between the levels in the racks should be protected. This is done with N-pipes
running in strings throughout the whole rack and on all levels except the top level which is protected by the ceiling nozzles.
To supply the N-pipes with water and to detect the fire, thermal activated valves are used. For each running 3 meter N-pipe such
a valve is installed. Water should be supplied to all valves.
In case of fire the valve/valves closes to the fire will open automatically as the thermal link holding the valves closed, breaks by
the heat. Each valve will supply water for 3meter N-pipe on both sides of the valve.
In case of fire spread, other valves will automatic open and distribute water where needed.
There should as minimum be calculated water for protection of the total rack in height and at least 9 meter running meter rack.
Prices and system design is supplied on project base. For assistance contact the sales department.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 27 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.5 Application: Military, air force, navy
Application:
System model
System type
Military, air force, navy
Model F48
Model F102
Pop-up nozzle for deck protection Pop-up nozzle for hangar
protection
4.5.1 Model F48 - deck nozzle
Model F48 deck nozzles are designed for fire protection and
cooling of decks for example helicopter decks or navy ship
decks for protection and flushing of decks.
The Model F48 design allows the nozzles to be cast into the
deck coating, and at a later time being serviced without
dismounting the nozzles from the deck coating.
On customer request Model F48 nozzles are custom designed
to specific deck thickness etc. Listed prices are for standard
versions made in Stainless steel (AISI 316):
Type:
Normal application:
Materials:
Connection/thread:
Water pressures:
Dropsize Dv90:
K-factor:
Installation height:
Spray height:
Nozzle coverage diameter:
Floor nozzle
Deck protection
Stainless steel 316
¾” BSP or ¾” NPT
2 – 16 bars
< 350μm
48 l/min/√bar
Imbedded in deck.
Range: 0.8m at 2bar. 0.95m at 6bar
Range: 8.4m at 2bar. 10.6m at 6bar.
Product
Variant
Model F48
Full assembly with drain in
house
Full assembly without drain
in house
Model F48
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 28 of 44
Sales and order
no:
10298
Package size
Package price DKK/Euro
10
On request
10299
10
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.5.2 VID Model F102 - aircraft hangar low pressure water mist nozzle
The nozzles are installed in military aircraft hangars (NATO) to
protect helicopters, fighter planes, transport - and aviation planes
against fire, with only pure water mist as the extinguishing agent.
The nozzles do automatic elevate from the floor surface of the
hangar to distribute water mist sprays in case of fire. They are cast
into the hangar floors to be positioned flush to the floor surface.
Type:
Normal application:
Materials:
Connection/thread:
Water pressures:
Dropsize Dv90:
K-factor:
Installation height:
Nozzle coverage:
Spray angle:
Floor nozzle
Hangar protection
Stainless steel 316
¾” BSP-T female.
8 – 16 bars
< 350μm
10 l/min/√bar
Imbedded in floor.
2m x 4m
Horizontal 95 º
Product
Variant
Model F102
Model F102
Full assembly – one way spray
Full assembly – two way spray
Sales and order
no:
F102-10305
F102-10306
Package size
Package price DKK/Euro/GBP
1
1
On request
On request
4.6 Application: Road tunnels, rail, tunnels, metro tunnels, cable tunnels, etc.
Application:
System model
System type
Road tunnels, rail, tunnels, metro tunnels, cable tunnels, etc.
Model Tunprotec
Modular build system with integrated detection and activation
system. Modules pre- fabricated and pre-tested from factory for fast,
easy and simple installation.
4.6.1 Model Tunprotec – Watermist system for protection of infrastructure tunnels.
The tunnel system is a low pressure water mist system with an integrated double knock detection system.
The active fire fighting system operates with a minimum water pressure on the nozzles of 10 bars. The system consists of tunnel
modules for installation inside the tunnel pipe, and a pump skid to supply water to the tunnel protection modules inside the
tunnel pipe. The installation inside tunnel pipes consist of pre-assembled pipe modules of 10m in lengths, which are installed in
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 29 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
centre of the tunnel pipe, and which divide the whole tunnel length into protection zones. Each protection zone being 20m long,
and covering the whole tunnel width (maximum 10m).The Tunnel Modules include tunnel riser pipe, nozzle pipes, water mist
nozzles, monitored stop and activation valve. The tunnel modules are flanged assembled together to form a continuous string of
pipes in the tunnel pipe ceiling. The tunnel modules include hangers to make a fast and efficient installation in the tunnel pipe.
In case of a fire in the tunnel pipe, the tunnel protection system automatically activates and distributes water mist in the
protection zone, where the fire was detected and its two neighbour zones. Water mist is distributed in total tunnel length of
60m.The system delivers a minimum water density of 2.5 mm/min in the protected area, with a waterflow of approximately
1610 l/min at 10 bar over three 20m zones. The system has been successfully tested in accordance to the UPTUN test
programme with this configuration. The system has been tested in fires with HRR up from5MW - 100MW in the Runhammar test
tunnel.
The double knock detection system consists of linear heat detection throughout the tunnel and two flame detectors in each
zone. The signals from the detection systems are sampled in a local control box. Every 20 control boxes are connected in a Can
Bus and sampled in a gateway panel. All gateway panels are connected in fiber optics to a control computer. The control
computer is supplied with software for visual overview and active control and activation of the system. The system can also
activate manually if needed.
The Tunprotec system can be supplied with hydraulic system and detection system integrated or can be supplied as separate
systems. The hydraulic system comes in different sizes depending on tunnel length.
Prices and system design is supplied on project base. For assistance contact the sales department.
4.7 Application: Rolling stock, train wagons, metro wagons
Application:
System model
System type
Rolling stock, train wagons, metro wagons
Model Wagon
Model BPS
Total protection of rolling stock.
Complete bus engine protection
system.
4.7.1 Model Wagon – Watermist system for protection on rolling stock.
The Wagon system provides fast fire detection with double knock fire detection system.
It allocates the location of fire to automatically activate active fire fighting with water mist enhanced with aspirated
film forming foam, directly on the place on fire providing supreme fire suppression capacity with minimum agent
consumption.
The VID Fire-Kill Wagon fire protection system is suitable for automatic fire protection inside passenger
compartments as well as of technical installations located outside the passenger compartment.
The VID Fire-Kill Wagon system is custom designed to match the design of the individual wagons. The Wagon
Systems is a fully monitored system applying VID Fire-Kill, standard products.
Prices and system design is supplied on project base. For assistance contact the sales department.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 30 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
4.7.2 Model BPS – Standalone system for protection of vehicle engine rooms.
The VID Fire-Kill Model BPS system is a little local application fire extinguishing system designed for fast response fire
fighting in mobile machinery spaces, such as in trucks and busses and entrepreneur machineries etc.
The System is a 7 bar air pressurized standalone system which automatically fights fires in engine room
compartments with sprays of: Water Mist with 3% foam enhancement (AFFF), Where the water mist provides good
cooling in the well ventilated engine room compartments and the foam enhancement provides good fire
extinguishing in locations where fuel assembles in minor pools hidden to direct sprays hidden, and provide fast fire
knockdown and protection against fires reigniting.
Prices and system design is supplied on project base. For assistance contact the sales department.
4.8 Application: Underground carparks and garages.
Underground Car parks spaces are defined as areas with large fuel loads situated next to each other, and with many potential
ignition sources in the area.
For such applications systems may be automatically activated, manually activated or automatically activated with manual
release capabilities, all depending on the local authority.
To cover such a risk, VID Fire-Kill can offer Low Pressure Water Mist Nozzles Model OH-OPX1 which are patented open, low
pressure water mist nozzles, ideal for installations where cars and trucks are parked. The nozzles provide a highly reliable and
enhanced firefighting performance along with low water requirements.
The nozzles have been tested in accordance with IMO Resolution MSC.1/Circ. 1272 for RORO spaces and special category spaces
and Model OH-OPX1 nozzles are MED and TA approved by DNV.
Below is an overview of the different open and automatic nozzles:
Nozzle name
Application
Nozzle type
Spacing
Tested to
Suez OH-OPX1
Vehicle decks up 2.5m ceiling height.
Open nozzle
2
4m x 4m (16m )
MSC.1/Circ. 1272 for vehicle decks up to 2.5m
ceiling height.
Panama OH-OPX1
Vehicle decks up 5m ceiling height.
Open nozzle
2
3.5m x 3.5m (12.25m )
MSC.1/Circ. 1272 for vehicle decks up to 5m ceiling height.
Approval
DNV, MED
DNV, MED
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 31 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Open Nozzle - Model Suez & Panama OH-OPX1
Type:
Materials:
Nozzle body finish:
Water pressure:
Dropsize Dv90:
K-factor:
Connection/thread:
Approval:
Pendent
Brass / stainless steel
NiSn
6 – 16 bars (tested at 6 bar)
< 350μm
23 l/min/√bar
½” BSP or ½” NPT
DNV MED-B-8011 & TA F-20291
Application Ceiling height:
Installation height:
Nozzle spacing:
Nozzle brand name:
1.5 – 2.5m
Max. 2.5 m.
Max. 4 m., 2 m. to walls
Suez
Product
Material
Model Suez & Panama OHOPX1
Model Suez & Panama OHOPX1
Model Suez & Panama OHOPX1
Material: Brass + NiSn
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 32 of 44
Material: Stainless steel
316L
Material: Titanium Grade
2
2.5 – 5.0m
Max. 5 m.
Max. 3.5 m., 1.75 m. to walls
Panama
Sales
and
order no:
SUEX-PAN10334
SUEX-PAN10335
SUEX-PAN10336
Package size
Package price DKK/Euro/GBP
30
On request
30
On request
30
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
5. Water spray nozzles.
5.1 High velocity nozzles
5.1.1 Type HS
The Type HS nozzles are designed to provide water-spray for fire
protection against hydro-carbon fires such as off-shore installations,
transformers, refineries etc. These nozzles distribute water in sprays of
relatively large droplets which makes the water spray little sensitive to
windy conditions. Type HS nozzles are available with and without
strainers. Strainers come in same material as nozzle house. Type HS
nozzles are FM approved.
Type:
Normal application:
Materials:
Connection/thread:
Water pressures:
K-factor:
Spray angle:
Nozzle Strainer:
Product
HS23-120
HS23-120
HS23-120
HS23-120
HS23-120
HS23-120
HS23-120
HS23-120
HS23-120
HS43-120
HS43-120
HS43-120
HS43-120
High velocity nozzle
Off-shore installations, transformers, refineries
Brass + NiSn, Naval Brass, SS AISI 316, Titanium Grade 2.
1” NPT.
2 – 16 bars
24.5, 42.5, 80 (FM approved version). Others: 66.
Full cone 120º and 90º (FM approved version). Others: 60º.
Optional
Variant
Materials
Strainer
Sales
and
order no:
Package
size
Package price DKK/Euro/GBP
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
K-factor: 24.5,
angle: 120°
Brass + NiSn
w.o. S
HS23-10504
30
On request
Naval brass
CuZn35Ni
AISI 316L
w.o. S
HS23-10505
30
On request
w.o. S
HS23-10506
50
On request
Titanium
Grade 2
Brass + NiSn
w.o. S
HS23-10507
50
On request
w. S
HS23-10512
30
On request
Naval brass
CuZn35Ni
AISI 316L
w. S
HS23-10513
30
On request
w. S
HS23-10514
50
On request
Titanium
Grade 2
w. S
HS23-10515
50
On request
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
Brass + NiSn
w.o. S
HS43-10500
30
On request
Naval brass
CuZn35Ni
AISI 316L
w.o. S
HS43-10501
30
On request
w.o. S
HS43-10502
50
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 33 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
HS43-120
HS43-120
HS43-120
HS43-120
HS43-120
HS66-60
HS66-60
HS66-60
HS66-60
HS66-60
HS66-60
HS66-60
HS66-60
HS66-60
HS80-90
HS80-90
HS80-90
HS80-90
HS80-90
HS80-90
HS80-90
HS80-90
HS80-90
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
K-factor: 42.5,
angle: 120°
Titanium
Grade 2
Brass + NiSn
w.o. S
HS43-10503
50
On request
w. S
HS43-10508
30
On request
Naval brass
CuZn35Ni
AISI 316L
w. S
HS43-10509
30
On request
w. S
HS43-10510
50
On request
Titanium
Grade 2
w. S
HS43-10511
50
On request
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
K-factor: 66,
angle: 60°
Brass + NiSn
w.o. S
HS66-10516
30
On request
Naval brass
CuZn35Ni
AISI 316L
w.o. S
HS66-10517
30
On request
w.o. S
HS66-10518
50
On request
Titanium
Grade 2
Brass + NiSn
w.o. S
HS66-10519
50
On request
w. S
HS66-10520
30
On request
Naval brass
CuZn35Ni
AISI 316L
w. S
HS66-10521
30
On request
w. S
HS66-10522
50
On request
Titanium
Grade 2
w. S
HS66-10523
50
On request
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
K-factor: 80.0,
angle: 90°
Brass + NiSn
w.o. S
HS80-10524
30
On request
Naval brass
CuZn35Ni
AISI 316L
w.o. S
HS80-10525
30
On request
w.o. S
HS80-10526
50
On request
Titanium
Grade 2
Brass + NiSn
w.o. S
HS80-10527
50
On request
w. S
HS80-10528
30
On request
Naval brass
CuZn35Ni
AISI 316L
w. S
HS80-10529
30
On request
w. S
HS80-10530
50
On request
Titanium
Grade 2
w. S
HS80-10531
50
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 34 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
5.2 Medium velocity nozzles
5.2.1 Type MS
The medium velocity spray nozzle is a vital part of deluge systems for
the protection of plant structures and machineries against fires,
which involve flammable liquids and solids. Type MS nozzles are as
standard available with ½” NPT connection.
Type:
Normal application:
Materials:
Connection/thread:
Water pressures:
K-factor:
Spray angle:
Product
MS16MS16-90
MS16-90
MS16-90
MS16-90
MS16-120
MS16-120
MS16-120
MS16-120
MS23MS23-90
MS23-90
MS23-90
MS23-90
MS23-120
MS23-120
Medium velocity nozzle
Off-shore installations, transformers,
refineries
Brass + NiSn, Naval Brass, SS AISI 316,
Titanium Grade 2.
1/2” NPT.
1.5 – 16 bars
16, 23, 40 & 59.
Full cone 90º & 120º.
Variant
Materials
Sales and order
no:
Package
size
Package price DKK/Euro/GBP
K-factor: 16,
angle: 90°
K-factor: 16,
angle: 90°
K-factor: 16,
angle: 90°
K-factor: 16,
angle: 90°
K-factor: 16,
angle: 120°
K-factor: 16,
angle: 120°
K-factor: 16,
angle: 120°
K-factor: 16,
angle: 120°
Brass + NiSn
MS16-90-10604
30
On request
Naval brass CuZn35Ni
MS16-90-10605
30
On request
AISI 316L
MS16-90-10606
50
On request
Titanium Grade 2
MS16-90-10607
50
On request
Brass + NiSn
MS16-120-10612
30
On request
Naval brass CuZn35Ni
MS16-120-10613
30
On request
AISI 316L
MS16-120-10614
50
On request
Titanium Grade 2
MS16-120-10615
50
On request
K-factor: 23,
angle: 90°
K-factor: 23,
angle: 90°
K-factor: 23,
angle: 90°
K-factor: 23,
angle: 90°
K-factor: 23,
angle: 120°
K-factor: 23,
angle: 120°
Brass + NiSn
MS23-90-10600
30
On request
Naval brass CuZn35Ni
MS23-90-10601
30
On request
AISI 316L
MS23-90-10602
50
On request
Titanium Grade 2
MS23-90-10603
50
On request
Brass + NiSn
MS23-120-10608
30
On request
Naval brass CuZn35Ni
MS23-120-10609
30
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 35 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
MS23-120
MS23-120
MS40-60
MS40-90
MS40-90
MS40-90
MS40-90
MS40-120
MS40-120
MS40-120
MS40-120
MS59-90
MS59-90
MS59-90
MS59-90
MS59-90
MS59-120
MS59-120
MS59-120
MS59-120
K-factor: 23,
angle: 120°
K-factor: 23,
angle: 120°
AISI 316L
MS23-120-10610
50
On request
Titanium Grade 2
MS23-120-10611
50
On request
K-factor: 40,
angle: 90°
K-factor: 40,
angle: 90°
K-factor: 40,
angle: 90°
K-factor: 40,
angle: 90°
K-factor: 40,
angle: 120°
K-factor: 40,
angle: 120°
K-factor: 40,
angle: 120°
K-factor: 40,
angle: 120°
Brass + NiSn
MS40-90-10616
30
On request
Naval brass CuZn35Ni
MS40-90-10617
30
On request
AISI 316L
MS40-90-10618
50
On request
Titanium Grade 2
MS40-90-10619
50
On request
Brass + NiSn
MS40-120-10620
30
On request
Naval brass CuZn35Ni
MS40-120-10621
30
On request
AISI 316L
MS40-120-10622
50
On request
Titanium Grade 2
MS40-120-10623
50
On request
K-factor: 59,
angle: 90°
K-factor: 59,
angle: 90°
K-factor: 59,
angle: 90°
K-factor: 59,
angle: 90°
K-factor: 59,
angle: 120°
K-factor: 59,
angle: 120°
K-factor: 59,
angle: 120°
K-factor: 59,
angle: 120°
Brass + NiSn
MS59-90-10624
30
On request
Naval brass CuZn35Ni
MS59-90-10625
30
On request
AISI 316L
MS59-90-10626
50
On request
Titanium Grade 2
MS59-90-10627
50
On request
Brass + NiSn
MS59-120-10628
30
On request
Naval brass CuZn35Ni
MS59-120-10629
30
On request
AISI 316L
MS59-120-10630
50
On request
Titanium Grade 2
MS59-120-10631
50
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 36 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
6. Valves
6.1 Control Valves
6.1.1 Model C-EL – electrical operated control valve
Model C control valves are designed to control water access to
nozzle pipes on sprinkler style and low pressure water mist
systems. Model C control valves are installed in local application
systems and deluge systems, in pipe system designed with PN16
pipes. The valves are operated by a 12VDC solenoid valve. The
valve in – and outlet are placed in a 90 degree position for easy service and maintenance. The valves are made in Stainless steel
316 and come with flange connection. The valves can be supplied in different sizes with different pressure loss curves depending
on the waterflow.
The valve can are delivered with different operation methods which includes manual release and electrical release through
solenoid valve. The valves can be delivered with either normal 24VDC,8W solenoid valve or Impulse 24VDC,10W solenoid valve.
As standard they are delivered with normal solenoid valve.
Gaskets and O-rings shall be replaced accordingly to their schedules. Basic gaskets shall be replaced every two years, and full
gaskets shall be replaced every four years. Basic and Full gasket kits can be supplied by request.
Materials:
Valve Design:
Working pressure:
Test pressure:
Size:
AISI SS316L
Valve in angle design with flange and threads in- and outlet ports.
0.5 bar – 16 bar
Factory tested to maximum 25 bar ½ hour.
DN50/2”, DN80/3”
Product
Size
Variant
C-EL-50-50
Size: 2”,
Inlet: DN50,
Outlet: DN50.
C-EL-50-50Impulse
Size: 2”,
Inlet: DN50,
Outlet: DN50.
C-EL-80-80
Size: 3”,
Inlet: DN80,
Outlet: DN80.
C-EL-80-80Impulse
Size: 3”,
Inlet: DN80,
Outlet: DN80.
C-EL-2”-2”
Size: 2”
Inlet: 2”
Outlet: 2”
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
impulse solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
impulse solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
solenoid valve.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 37 of 44
Sales and
order no:
CEL10401
Package
size
1
Package price
DKK/Euro/GBP
On request
CEL10402
1
On request
CEL10403
1
On request
CEL10404
1
On request
CEL10405
1
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
C-EL-2”-2”Impulse
Size: 2”
Inlet: 2”
Outlet: 2”
C-EL-3”-3”
Size: 3”
Inlet: 3”
Outlet: 3”
C-EL-3”-3”Impulse
Size: 3”
Inlet: 3”
Outlet: 3”
Spares
To be used for
product types
For 2” / DN50 CEL & C-EL-PR
valves
For 2” / DN50 CEL & C-EL-PR
valves
Basic Gasket
Kit for C-EL
Full Gasket
Kit for C-EL
Basic Gasket
Kit for C-EL
Full Gasket
Kit for C-EL
For 3” / DN80 CEL & C-EL-PR
valves
For 3” / DN80 CEL & C-EL-PR
valves
Model C-EL
Valve
Wrench
Model C-EL
Core
For 3” / DN80 CEL & C-EL-PR
valves
For 2” / DN50 CEL & C-EL-PR
valves
Model C-EL
Core
For 3” / DN80 CEL & C-EL-PR
valves
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 38 of 44
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
impulse solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
solenoid valve.
Stainless steel 316 control valve
with easy to maintain function,
drain, 2 x pressure gauges, 1 x
impulse solenoid valve.
Includes
Includes:
1 x Valve Piston O-ring
1 x O-ring Lubricant
Includes:
Basic gasket kit +
1 x Flange Gasket
1 x Valve plate Gasket
1 x Valve Spring
Includes:
1 x Valve Piston O-ring
1 x O-ring Lubricant
Includes:
Basic gasket kit +
1 x Flange Gasket
1 x Valve plate Gasket
1 x Valve Spring
1 x Wrench for use when servicing
the 3”/DN80 valve core.
1 x Valve core for 2” / DN50 size
valve. To be used for fast full
servicing instead of changing valve
core seals.
1 x Valve core for 3” / DN80 size
valve. To be used for fast full
servicing instead of changing valve
core seals.
CEL10406
1
On request
CEL10425
1
On request
CEL10426
1
On request
Sales and
order no:
CEL10427
Package
size
1
Package price
DKK/Euro/GBP
On request
CEL10419
1
On request
CEL10420
1
On request
CEL10421
1
On request
CEL10422
1
On request
CEL10423
1
On request
CEL10424
1
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
6.2 Pre-Action Valves
6.2.1 Model C-EL-PR – Pre-action valves
The VID Fire-Kill Model C-EL-PA Pre-Action Control Valves are a series of robust and reliable pre-action, angle positioned, pilot
controlled valves created entirely in Stainless Steel (316L) capable of functioning under harsh conditions and designed to be
connected to systems where no corrosion is allowed. The inclusion of the Model C-EL-PA Pre-Action trim, allows the system to
monitor dry-pipe pressure drops, creating an additional means of false alarm prevention.
The Model C-EL-PA Control Valve features smaller external trim than other conventional pre-action valves, making the valve
easy to install and limits the end-product costs, and greatly diminishes the spatial requirements of such valves.
The Valve can easily be disassembled for easy maintenance and refurbishment, without removing the valve housing from the
connected system.
Gaskets and O-rings shall be replaced accordingly to their schedules. Basic gaskets shall be replaced every two years, and full
gaskets shall be replaced every four years. Basic and Full gasket kits can be supplied by request.
Materials:
Valve Design:
Working pressure:
Working air pressure:
Alarm pressure value:
Pressure drop signal:
Size:
AISI SS316L
Valve in angle design with flange and thread in- and outlet ports.
0.5 bar – 16 bar
4 – 6 bar
2.5 – 3 bar
Relay NO or NC.
DN50/2”, DN80/3”
Product
Size
Variant
C-EL-PA
Fits to C-EL
versions: 2”, 3”,
DN50, DN80
Pre-action trim and test valve built
into Model C-EL deluge valves.
Sales and
order no:
CELPA10428
Package
size
1
Package price
DKK/Euro/GBP
On request *
* The price does not include a C-EL valve. See chapter 6.1.1 for individual C-EL valve prices.
6.3 Alarm Check Valves for wet pipe systems.
6.3.1 Model WAC - wet alarm check valve
Valves for installation in wet pipe sprinkler and low pressure water
mist systems. Valves are available in DN 50 & DN 40 versions for PN
16 bar working pressure. The valves perform as clapper check with
electric flow alarm. Flow alarm is inductive without direct contact to
moving parts. The valves have built in alarm test, drain and electrical
anti false alarm, in the form of a in time delay relay (8 sec) to avoid
false alarms from water pressure surges in the pipe system.
The valves, as Vafer Style Type, are installed between two flanges
and are made in bronze.
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 39 of 44
Anti False Alarm Unit
Serial No.:
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Materials:
Valve Design:
Working pressure:
Test pressure:
Bronze
Valve are Vafer Style design to be installed between flanges.
0.5 bar – 16 bar
Factory tested to maximum 25 bar ½ hour.
Product
Variant:
Package size
Package price DKK/Euro/GBP
DN50
Sales and order
no:
WAC-10407
Complete w. anti false alarm
unit
Complete w. Anti false alarm
unit
Spares
Gasket kit
Gasket kit
Inductive alarm kit (house &
sensor)
Spindel & hangers
Spindel & hangers
Anti false alarm unit (print)
DN50 – DN60 installation
adapters
1
On request
DN40
WAC-10408
1
On request
DN50
DN40
DN40 & DN 50
WAC-10409
WAC-10410
WAC-10411
1
1
1
On request
On request
On request
DN 50
DN 40
DN 40 & DN 50
DN 60
WAC-10412
WAC-10413
WAC-10414
WAC-10429
1
1
1
8
On request
On request
On request
On request
6.4 One-shot deluge valves.
65 mm
6.4.1 Model SUFA100 – Thermal and electrical
activated one-shot valves.
Working pressure:
Test pressure:
Operation bulb temp.:
SUFA 100 X 2
47 mm
Materials:
Finish:
KV-Factor(SUFA 1x):
KV-Factor(SUFA 2x):
Valve Design:
3/4"
75 mm
VID Model SUFA 100 control valves are a series of small robust
one shot valves, which are designed for control of water from wet
supply pipes to nozzle pipes with water spray or low pressure
water mist systems. For thermal activation, the nominal release
temperature should be specified at order.
35 mm
Brass CuZn58
NiSn.
70 liter/minute/√bar ± 3%, measured with 1m ¾” pipes on both outlet ports.
97 liter/minute/√bar ± 3%, measured with 1m ¾” pipes on both outlet ports.
Valve in angel/tee design with one/two ¾” BSP inline outlet ports and one ¾” centrally positioned
inlet port.
0.5 bar – 16 bar
Factory tested to maximum 28 bar ½ hour.
57,68,93ºC
Product
Variant:
Sales and order no:
Package size
Package price DKK/Euro/GBP
Model SUFA
100-1X
SUFA valve with one outlet
port and heat activation
SUFA-10415
1
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 40 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Model SUFA
100-2X
Model SUFA
100-1X-EL
Model SUFA
100-2X-EL
SUFA valve with two outlet
ports and heat activation
SUFA valve with one outlet
port and heat and electric
activation
SUFA valve with two outlet
ports and heat and electric
activation
SUFA-10416
1
On request
SUFA-10417
1
On request
SUFA-10418
1
On request
6.5 Pressure Reduction Valves
6.5.1 Model C-PR – Pressure reduction valve
The VID Fire-Kill Model C-PR Pressure Reduction Valve is a series of
Patented robust and reliable pressure reduction, angle positioned,
pilot controlled valves made entirely in Stainless Steel 316L for
operation in systems where it is necessary to reduce and control
water pressures independent of inlet pressure and flow. The
model C-PR valves are capable of function under harsh conditions
due to the robust design and due to the valve material all being
stainless steel 316L.
The Model C-PR Pressure Control Valves feature mostly internal trim and is therefore very compact making it easy to
fit most places. These unique features give high safety and differ from more conventional types of pressure control
valves. The Model C-PR valves are designed with a special turbo function making it possible to bypass the preset
reduced pressure, and get the full pressure instead. This function can be used in case of need of additional pressure
or flow.
The Model C-PR valve pressure reduction levels are preset and factory tested before supply. The valves shall always
be returned to VID Fire-Kill for adjustment and test if other settings are needed.
The Model C-PR pressure reduction Valves are suitable for installation in: Fixed firefighting systems to control of
water pressures at lower levels in high rise buildings, control of water pressures to system pipes requiring lower
water pressures, water pressure balancing of different water sprays systems on common water supply systems, and
control of water supply pressure to fire hoses for firefighting ( hydrant systems).
Materials:
Valve Design:
Working pressure:
Pressure reduction level:
Test pressure:
Size:
AISI SS316L
Valve in angle design with flange in- and outlet ports.
0.5 bar – 16 bar
4 – 16 bar
Factory tested to maximum 25 bar ½ hour.
DN50, DN80
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 41 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
Product
Size
Variant
C-PR-50-50
Size: 2”,
Inlet: DN50,
Outlet: DN50.
C-EL-80-80
Size: 3”,
Inlet: DN80,
Outlet: DN80.
C-EL-2”-2”
Size: 2”
Inlet: 2”
Outlet: 2”
C-EL-3”-3”
Size: 3”
Inlet: 3”
Outlet: 3”
Spares
Basic Gasket
Kit for C-PR
To be used for
product types
For 2” / DN50
C-PR valve
Stainless steel 316 pressure reduction
valve, 2 x pressure gauges, Pressure
control value to be specified at order
(between 4-16 bar)
Stainless steel 316 pressure reduction
valve, 2 x pressure gauges, Pressure
control value to be specified at order
(between 4-16 bar)
Stainless steel 316 pressure reduction
valve, 2 x pressure gauges, Pressure
control value to be specified at order
(between 4-16 bar)
Stainless steel 316 pressure reduction
valve, 2 x pressure gauges, Pressure
control value to be specified at order
(between 4-16 bar)
Includes
Full Gasket
Kit for C-PR
For 2” / DN50
C-PR valve
Basic Gasket
Kit for C-PR
For 3” / DN80
C-PR valve
Full Gasket
Kit for C-PR
For 3” / DN80
C-PR valve
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 42 of 44
Includes:
1 x Valve Piston O-ring
1 x O-ring Lubricant
Includes:
Basic gasket kit +
1 x Flange Gasket
1 x Valve Spring
Includes:
1 x Valve Piston O-ring
1 x O-ring Lubricant
Includes:
Basic gasket kit +
1 x Flange Gasket
1 x Valve Spring
Sales and
order no:
CPR-10430
Package
size
1
Package price
DKK/Euro/GBP
On request
CPR-10432
1
On request
CPR-10431
1
On request
CPR-10433
1
On request
Sales and
order no:
CPR-10434
Package
size
1
Package price
DKK/Euro/GBP
On request
CPR-10435
1
On request
CPR-10436
1
On request
CPR-10437
1
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
7. Detection Systems
7.1 Flame detectors
7.1.1 Type DeFlameTec, model VFK-FD1 Flame detector.
The CE marked DeFlameTec flame detector is a patented, robust and reliable flame
detector which has been successfully tested to the EN54-10 for flame detectors. The
Deflametec flame detector is an ATEX class 2 approved flame detector.
DeFlameTec detectors provide the means of reducing risks of false alarms to a
minimum. DeFlameTec detects fires exclusively from the narrow spectral range, which
equals the light radiated from carbon oxidation.
Further, a time delay can be set so the alarm signal first is transferred after it has seen
a flame for a certain time.
The DeFlameTec detector is housed in a stainless steel casing, which is water and dust
proof for IP class 67.
All output signals are supplied from either Normally Open (NO) or Normally Closed (NC) signal.
Material house:
Power supply:
Housing:
Output Signal:
Angle Horizontal:
Angle Vertical:
Visibility:
Delay options:
AISI 316L
24VDC
IP67
NO/NC
140°
140°
Approximately 30m
FD1: 3 impulses in 30 seconds
FD2: 50 impulses in 5 seconds
FD3: 5 impulses in 1 second
FD4: Customer defined.
Product
Variant:
Sales and order no:
Package size
Package price DKK/Euro/GBP
VFK-FD1-NO
VFK-FD1-NC
VFK-FD2-NO
VFK-FD2-NC
VFK-FD3-NO
VFK-FD3-NC
VFK-FD4-NO
VFK-FD4-NC
Normally Open (NO)
Normally Closed (NC)
Normally Open (NO)
Normally Closed (NC)
Normally Open (NO)
Normally Closed (NC)
Normally Open (NO)
Normally Closed (NC)
DEFLAMETEC-10701
DEFLAMETEC-10702
DEFLAMETEC-10704
DEFLAMETEC-10705
DEFLAMETEC-10706
DEFLAMETEC-10707
DEFLAMETEC-10708
DEFLAMETEC-10709
1
1
1
1
1
1
1
1
On request
On request
On request
On request
On request
On request
On request
On request
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 43 of 44
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,
Catalogue2015
7.2 Heat detectors
7.2.1 Model DA-1 – Thermal ”Rate of Rise” detector.
The VID Fire-Kill Model DA1 system is an automatic, reliable and safe detection and activation system.
The system consists of a small electrical panel, a power-supply and a thermocouple.
The electrical panel is powered with 12V DC / 2A, and has a built in 24 hour back-up power supply. The power supply, which
comes with the Model DA1, is a 230V AC – 12V DC power supply.
The thermocouple is 5 meter long, but can be made in lengths according to the customer’s wish. The thermocouple should be
placed, where the risk of fire is highest, or in the centre of the room. In case of fire, the panel can send a 12VDC signal as well as
one NO/NC relay signal.
Thermocouple:
Temperature area:
Standard ROR value:
Power supply:
Alarm Outputs:
Product
Model DA-1
Model DA-1
Model DA-1
Model DA-1
Model DA-1
Model DA-1
Type K
50-100 °C
0.25°C/sec over 3 seconds
1 x 12VDC
1 x relay signal NC
Variant – Alarm
temperature
50°C
60°C
70°C
80°C
90°C
100°C
Doc. no.: 150105-1
Doc.Name: Catalogue 2015 rev1
Page: 44 of 44
Sales and order no:
Package size
Package price DKK/Euro/GBP
DA1-10710
DA1-10711
DA1-10712
DA1-10713
DA1-10714
DA1-10715
1
1
1
1
1
1
On request
On request
On request
On request
On request
On request
VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg,
Tel: +45 6262 1024, Fax: +45 6262 3661, www.vid.eu,