INSTALLATION INSTRUCTIONS
ENTICE SERIES
PREMIUM ENTRANCE SYSTEM
INTERIOR GLAZE
ALUMINUM
Phone: (800) 421-6144 • Fax: (800) 582-7501
crlaurence.com • usalum.com • crl-arch.com
11M0120
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
HANDLING, STORAGE, AND PROTECTION OF ALUMINUM
The following precautions are recommended to protect the material against damage. Following these
precautions will help ensure early acceptance of your products and workmanship.
A.HANDLE CAREFULLY.
All aluminum materials at job site must be stored in a safe place, well removed from possible damage by other trades.
Cardboard wrapped or paper interleaved materials must be kept dry.
B.CHECK ARRIVING MATERIALS.
Check for quantities and keep records of where various materials are stored.
C. KEEP MATERIALS AWAY FROM WATER, MUD, AND SPRAY.
Prevent cement plaster or other materials from damaging the finish.
D. PROTECT THE MATERIALS AFTER ERECTION.
Protect erected frame with polyethylene or canvas splatter screen. Cement, plaster, terrazzo, other alkaline solutions, and
acid based materials used to clean masonry are harmful to the finish. If any of these materials come in contact with the
aluminum, immediately remove with water and mild soap.
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE BEGINNING INSTALLATION.
crlaurence.com | usalum.com
2
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
GENERAL INSTALLATION NOTES
Recommended Guidelines For All Installations:
1. REVIEW CONTRACT DOCUMENTS. Check shop drawings, installation instructions, architectural drawings, and
shipping lists to become thoroughly familiar with the project. The shop drawings take precedence and include
specific details for the project. Note any field verified notes on the shop drawings prior to installing. The installation
instructions are of a general nature and cover most conditions.
2. INSTALLATION. All materials are to be installed plumb, level, and true. Install operable windows preglazed only.
3. BENCH MARKS. All work should start from bench marks and/or column lines as established by the architectural
drawings and the general contractor with guaranteed accuracy. Working from these datum points and lines
determine:
a) The plane of the wall in reference to offset lines provided on each floor.
b) The finish floor lines in reference to bench marks on the outer building columns.
c) Mullion spacing from both ends of masonry opening to prevent dimensional build-up of daylight opening.
4. FIELD WELDING. All field welding must be adequately shielded to avoid any splatter on glass or aluminum. Results
will be unsightly and/or structurally unsound. Advise general contractor and other trades accordingly. All field welds
of steel anchors must receive touch-up paint (zinc chromate) to avoid rust.
5. SURROUNDING CONDITIONS. Make certain that construction which will receive your materials is in accordance
with the contract documents. If not, notify the general contractor in writing and resolve differences before
proceeding with work.
6. I SOLATION OF ALUMINUM. Aluminum to be placed in direct contact with uncured masonry or incompatible
materials should be isolated with a heavy coat of zinc chromate or bituminous paint.
7. SEALANTS. Sealants must be compatible with all materials with which they have contact, including other sealant
surfaces. Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility,
cleaning, priming, tooling, adhesion, etc. It is the responsibility of the Glazing Contractor to submit a statement
from the sealant manufacturer indicating that glass and glazing materials have been tested for compatibility and
adhesion with glazing sealants, and interpreting test results relative to material performance, including
recommendations for primers and substrate preparation required to obtain adhesion. The chemical compatibility of
all glazing materials and framing sealants with each other and with like materials used in glass fabrication must be
established. This is required on every project.
8. FASTENING. Within the body of these instructions "fastening" means any method of securing one part to another
or to adjacent materials. Only those fasteners used within the system are specified in these instructions. Due to the
varying perimeter conditions and performance requirements, perimeter and anchor fasteners are not specified in
these instructions. For perimeter and anchor fasteners refer to the shop drawings or consult the fastener supplier.
9. BUILDING CODES. Due to the diversity in state/provincial local, and federal laws and codes that govern the design
and application of architectural products, it is the responsibility of the individual architect, owner, and installer to
assure that products selected for use on projects comply with all the applicable building codes and laws.
U.S. Aluminum exercises no control over the use or application of its products, glazing materials, and operating
hardware and assumes no responsibility thereof.
10. EXPANSION JOINTS. Expansion joints and perimeter seals shown in these instructions and in the shop drawings
are shown at normal size. Actual dimensions may vary due to perimeter conditions and/or difference in metal
temperature between the time of fabrication and the time of installation. Gaps between expansion members should
be based on temperature at time of installation.
11. WATER HOSE TEST. As soon as a representative amount of the wall has been glazed (500 square feet or 46.5 m2)
a water hose test should be conducted in accordance with AAMA 501.2 specifications to check the installation.
On all jobs the hose test should be repeated every 500 square feet (46.5 m2) during the glazing operation.
12. COORDINATION WITH OTHER TRADES. Coordinate with the general contractor any sequence with other trades
which offset curtain wall installation (i.e. fire proofing, back-up walls, partitions, ceilings, mechanical ducts,
converters, etc.)
13. CARE AND MAINTENANCE. Final cleaning of exposed aluminum surfaces should be done in accordance with
AAMA 609.1 for anodized aluminum and 610.1 for painted aluminum.
crlaurence.com | usalum.com
3
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
ORDER OF ASSEMBLY AND INSTALLATION
FABRICATION CALCULATIONS
���������������������������������������������������������������������
5
PARTS IDENTIFICATION�������������������������������������������������������������������������� 6 - 7
SITE PREPARATION
��������������������������������������������������������������������������������
DOOR WITH SIDELITE INSTALLATION
Threshold Installation
���������������������������������������������������������������������������
Sub Sill Track Installation
�����������������������������������������������������������������������
Top Track and Header Installation
Wall Jamb Installation
������������������������������������������������������������
9
10
11
��������������������������������������������������������������
12
��������������������������������������������������������������������������
13
Top and Bottom Rail Installation
Sidelite Glass Installation
����������������������������������������������������������������
14
�����������������������������������������������������������������������
15
Doorway Jamb at Sidelite Installation
Doorway Jamb at Wall Installation
Cladding Installation
8
������������������������������������������������������
16 - 17
��������������������������������������������������������������
18
����������������������������������������������������������������������������
19
TRANSOM DOOR INSTALLATION
�����������������������������������������������������������������
Transom Doorway Jamb Installation
20
������������������������������������������������������������
21
��������������������������������������������������������������
21
Transom Top Rail Installation
�������������������������������������������������������������������
22
Transom Header Installation
��������������������������������������������������������������������
22
���������������������������������������������������������������������
23
�������������������������������������������������������������������������
24
������������������������������������������������������������������������
25
Transom Vertical Jamb Installation
Transom Glass Installation
Support Fin Installation
FIXED LITE INSTALLATION
Fixed Lite Top and Bottom Rail Installation
Fixed Lite Glass Installation
������������������������������������������������������
26
��������������������������������������������������������������������
27
Intermediate Vertical Mullion Installation
��������������������������������������������������������
DOUBLE DOOR WITH FRAME INSTALLATION
28
����������������������������������������������������
29
��������������������������������������������������������������
30
DOOR INSTALLATION
�����������������������������������������������������������������������������
31
PERIMETER SEALING
�����������������������������������������������������������������������������
32
OPTIONAL CORNER INSTALLATION
GLASS REPLACEMENT FOR DOORS
Remove Damaged Glass
�������������������������������������������������������������
33
�����������������������������������������������������������������������
33
Install Replacement Glass
�����������������������������������������������������������������
34 - 35
JOB SITE ESSENTIALS������������������������������������������������������������������������������ 36
crlaurence.com | usalum.com
4
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
FABRICATION CALCULATIONS
FABRICATION DEDUCTIONS:
Wall Jamb
Intermediate Vertical Mullion
Doorway Jamb
Sub Sill
Top Anchor Track and Sidelite Rail (Wall to Doorway)
Top Anchor Track and Sidelite Rail (Wall to Wall)
R.O. Height Minus 1-3/32” (27.8 mm)
R.O. Height Minus 9-13/32” (238.9 mm)
R.O. Height Minus 1/2” (12.7 mm)
R.O. Width Minus 1/2” (12.7 mm)
Minus 2-5/8” (66.7 mm)
Minus 3” (76.2 mm)
DOOR SIZE:
Door Height with Standard Header and Threshold
Door Height with Recessed Flush Header
(for Overhead Closer) and Threshold
Door Width
R.O. Height Minus 1-5/16” (33.3 mm)
R.O. Height Minus 27/32” (21.4 mm)
D.L.O. Minus 1/4” (6.4 mm)
Top Anchor Track
Top Rail
Header
Jamb Anchor
Doorway Jamb
Doorway Jamb
Wall Jamb
Intermediate Mullion
Door with Sidelite and Fixed Lite
Rough Opening Height
D.L.O.
Bottom Rail
Sub Sill
Threshold
Rough Opening Width
NOTE: R.O. =
D.L.O. =
Rough Opening
Daylight Opening
crlaurence.com | usalum.com
5
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
PARTS IDENTIFICATION
4” Square Door Rail Housing
4” Square Door Rail Clad
10” Door Rail Extension
2-5/8” Door Stile
2-5/8” Door Stile Clad
Vertical Stile
Vertical Stile Clad
Stile Glass Attachment Strip
Door / Wall Jamb Mount
Center Pivot Vertical Stile
Center Pivot Vertical Stile Clad
Header for Top Pivots
Header Clad
Half Saddle Threshold Offset Pivot
Saddle Threshold Offset Pivot
Saddle Threshold Center Pivot
Half Saddle Threshold Center Pivot
Threshold Offset Pivot End Cap
Sidelite Rail Exterior and Interior
Top Anchor
Sidelite Rail Exterior Top Anchor /
Interior Bottom Anchor
Sidelite Rail Fastening Clip
Sidelite Rail Setting Block
4’ Square Sidelite Rail Housing
4’ Square Sidelite Rail Clad
For replacement parts, please contact Technical Sales at (800) 582-7501.
crlaurence.com | usalum.com
6
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
PARTS IDENTIFICATION (CONTINUED)
Sidelite Rail Exterior
Bottom Anchor
Transom Header Main Body
Transom Header Main Body Clad
Transom Header Main Body Clad
Corner, Wall Jamb and Transom
Header Removable Stop
Corner Main Body Clad Tall
Corner Main Body Clad Short
Corner Tall Interior Removable
Stop L Clad
Corner Short Interior Removable
Stop L Clad
Corner Main Body
Wall Jamb Main Body
Vertical Mullion Main Body
Vertical Mullion Removable Stop
Vertical Mullion Removable Stop
Clad
Shear Clip Aluminum Clad OR
Stainless Steel Clad
Vertical Shear Clip
PART # GH342
PART # NP238
Gasket
Gasket
PART # 20092003
PART # 10X112HHDTEK
10-16 X 5/8” Hex Washer
Self Drilling Screw
10 X 1-1/2” Hex Washer
Self Drilling Screw
Corner Shear Clip
Recessed Shear Clip
1” x 4” x 1/8”
(25.4 mm x 101.6 mm x 3.2 mm)
65 +- 5 Durometer
Neoprene Edge Block
Setting Block
crlaurence.com | usalum.com
7
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
SITE PREPARATION
1. Review and measure the opening.
2. Verify rough window opening size 1/2” (12.7) clearance in both width and height to the window. Verify
framing is plumb, straight, and true around window opening. Measure opening at each end and at center
vertically and horizontally. Make corrections to openings as required. Measure opening diagonally to
check squareness. Chip concrete high points to flush and rounded corners to square.
Measure
LEVEL
VERTICAL DIMENSION
Measure
Measure
SQUARE
crlaurence.com | usalum.com
HORIZONTAL DIMENSION
8
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOOR WITH SIDELITE INSTALLATION
3
5
33
Door with Sidelite Installation Order
Sidelite
4
6
Door
7
8
10
5
2
4
1 Threshold
Page 10
2 Sub Sill
Page 11
3 Top Track and Header
Page 12
4 Wall Jamb
Page 13
5 Top and Bottom Rail
Page 14
6 Sidelite Glass
Page 15
7 Doorway Jamb at Sidelite
Page 16
8 Doorway Jamb at Wall
Page 18
9 Cladding
Page 19
10 Door
Page 31
11 Finishing and Sealing
Page 32
1
8
7
6
3
3
10
5
Wall Jamb
Exterior
Doorway Jamb
at Sidelite
Doorway Jamb
at Wall
5
Exterior
Exterior
2
1
Sidelite
crlaurence.com | usalum.com
Door
9
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
THRESHOLD INSTALLATION
1. Determine the perimeter centerline of the opening and location of the bottom door spindle from the shop
drawings.
2. Install the cement box and closer if applicable.
3. Apply a continuous bead of Cat. No. 33S Sealant to the floor substrate around the perimeter line below
the threshold. Leave two weep gaps for water drainage and set threshold while sealant is wet.
4. Fasten the threshold to the floor with the appropriate fasteners as specified in the engineering
requirements. Cover fastener heads with Cat. No. 33S Sealant.
NOTE: For installations with doors, the threshold must be installed first to determine the location of the other
components.
Threshold is notched on each end for Doorway Jambs that run through.
Centerline
Threshold
Closer
Drainage gaps
in sealant
Exterior
Cat. No. 33S
Sealant
Threshold Options
OR
Half Saddle Threshold
Offset Pivot
OR
Saddle Threshold Offset Pivot
OR
Saddle Threshold
Center Pivot
Half Saddle Threshold
Center Pivot
NOTE: Saddle Threshold Offset Pivot shown in illustrations.
crlaurence.com | usalum.com
10
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
SUB SILL TRACK INSTALLATION
NOTE: Sub Sills are delivered with Fastening Clips installed in the track and End Dams sealed at each end.
1. Shim at each screw with Cat. No. PHS4 Horseshoe Shims turned parallel to Sub Sill. Position screws
in center of slotted hole to allow for expansion.
SUB SILL
Fastening Clips and End Dams are factory installed.
Use holes in Sidelite Rails as a guide for Clip placement.
Maximum distance between clips = 9” (229 mm)
Non Slotted
Hole next to
Doorway
Concrete Screw
Threshold is
notched for
Doorway Jamb
Part No. 1/4 X 2-3/4 HWH TAPCON
SUB SILL
Position Non Slotted Hole next to Doorway
Jamb to prevent expansion into Doorway.
Position screws in
center of Slotted Holes.
Insert Cat. No. PHS4
Shim. Turn to parallel.
Do NOT block Weep Holes.
2. Seal over screw heads with Cat. No. 33S Sealant.
NOTE: Do NOT block weep holes in Sub Sill.
Cat. No. 33S.
crlaurence.com | usalum.com
11
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TOP TRACK AND HEADER INSTALLATION
TOP TRACK
TOP TRACK
HEADER
FASTENING CLIPS
CUT SHORT
CENTER
DIRECTLY
OVER
Fastening Clips must be installed before Sidelite Rails.
Use holes in Sidelite Rails as a guide for placement.
Maximum distance between clips = 9” (229 mm)
SUB SILL
MOUNT
DIRECTLY
ABOVE
THRESHOLD
1. Level and mount Header directly above Threshold.
2. Slide Fastening Clips into each top track. Mount track directly above Sub Sill. Secure with screws
centered in slots.
Position screws in
center of slotted holes.
Turn PHS4 Shims parallel.
Header is notched
for Doorway Jamb.
# 10 Fastener appropriate for substrate
TOP TRACK
HEADER
Fastening Clip
SUB SILL
Sidelite
crlaurence.com | usalum.com
THRESHOLD
Door
12
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
WALL JAMB INSTALLATION
1. Fit the Wall Jamb Main Body on the Sub Sill with the cladded side facing the exterior. Push it tight against
the End Dam and wall.
2. Shim and fasten to the wall.
NOTE: Cladded side faces exterior.
Main Body with Gasket
Cladded Side
WALL JAMB
SITS ON
SUB SILL
DOORWAY
JAMBS
RUN
THROUGH
SUB SILL
THRESHOLD
END DAMS
# 10 Fastener appropriate for substrate
Cladded Side
GASKET
Part No. GH342
WALL JAMB MAIN BODY
Position screws in
Turn PHS4 Shims parallel.
center of slotted holes.
Wall Jamb
(Assembled)
WALL JAMB
MAIN BODY
# 10 Fastener
GASKET
Part No. GH342
WALL JAMB
REMOVABLE STOP
Interior
END DAM
Wall Jamb sits on Sub Sill
tight against End Dam.
crlaurence.com | usalum.com
13
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TOP AND BOTTOM RAIL INSTALLATION
1. Position Top and Bottom Rails with Shear Clips next to Doorway Jamb.
2. Position Fastening Clips to line up with holes in Top and Bottom Rails. Secure with 10X112HHDTEK
drilling screws.
Wall Jamb
NOTE: Do not block the drain slots placed between the mounting holes.
Fastening Clips
Header slotted for Doorway Jamb
Top Rail
Shear Clip
attaches to
Doorway Jamb
Part No. 10X112HHDTEK
Shear Clip
Do not block Drain Slots.
Bottom Rail
Shear Clip
attaches to
Doorway Jamb
Shear Clip
Wall Jamb
Fastening Clips
Threshold slotted for Doorway Jamb
View from Exterior
NOTE: The Shear Clips also act as
spacers for the cladding. These clips
are used only where the Rail butts
against a Doorway Jamb.
Sidelite Rail Options
10” Sidelite Rail
4” Sidelite Rail
OR
Fastening Clip
10” Sidelite Rail Clip
NOTE: 4” Rails shown in illustrations.
crlaurence.com | usalum.com
14
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
SIDELITE GLASS INSTALLATION
1. Trim edges of the glass at face and sides with
a sharp utility knife to remove any excess
Silicone Sealant.
2. Place Setting Blocks at quarter points in Bottom
Rail and Edge Blocks at quarter points inside
Wall Jamb pocket.
1/4
Neoprene Edge Block
1/4
1/4
Setting Block
1/4
1/4
1/4
1/4
1/4
3. Lift and set glass into pocket. Position glass so one end is outside opening 1/2” (12.7 mm).
1
3
2
1/2” to 9/16”
(5 to 14.3 mm)
Glass Bite
crlaurence.com | usalum.com
1/2” to 17/32”
(5 to 13.5 mm)
Glass Bite
15
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOORWAY JAMB AT SIDELITE INSTALLATION
1. With Slotted Holes next to Top Rail, fit
Doorway Jamb onto glass and lightly
tap into place.
2. Secure Jamb to Top and Bottom Rail Shear
Clips with Cap Screws.
Slotted Holes at top
Tighten Cap Screws into
holes in Shear Clip
Wall Jamb
Main Body
Cap Screws
secure Jamb
to Sidelite Rails
Doorway
Jamb
NOTE: Spray glass edge with Cat. No. 1973 to
prevent Doorway Jamb Gaskets from binding.
3. Ensure glass is fully inserted into both Jambs.
Tighten Cap Screws into
holes in Shear Clip
Doorway Jamb
(Assembled)
1/2” (5 mm)
Minimum Glass Bite
CRITICAL
ULTRA NARROW
VERTICAL STILE
4. Fit Removable Stop to Wall Jamb Main Body and secure with screws at all predrilled hole locations.
Wall Jamb
GASKET
Part No. GH342
GASKET
Part No. GH342
WALL JAMB
REMOVABLE STOP
WALL JAMB
REMOVABLE STOP
Part No. 20092003
crlaurence.com | usalum.com
Wall Jamb
Removable Stop
Wall Jamb
Main Body
Interior
16
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOORWAY JAMB AT SIDELITE INSTALLATION (CONTINUED)
5. Hand tighten Set Screws in Doorway Jamb to center glass in Sidelite Rails. Torque 1/8 turn past tight to
secure.
Included Hex Driver
Wall Jamb
Doorway
Jamb
Set Screws can shift Jamb from
side to side for centering on Sidelite Rail.
6. Roll NP238 Gaskets into both sides of Top and Bottom Rails using a CRL Vinyl Roller.
Top Rail
Top Rail
Gasket
GASKET
GASKET
Part No. NP238
Part No. NP238
Gasket
Bottom Rail
Bottom Rail
Roll Gaskets into Rails
Sidelite (Assembled)
crlaurence.com | usalum.com
17
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOORWAY JAMB AT WALL INSTALLATION
1. Mount Jamb Anchor to wall.
Jamb Anchor
Header
Turn PHS4 Shims parallel.
Position screws in center of slotted holes. Secure Jamb Anchor to wall.
2. Place Doorway Jamb and secure using the Set Screws on each side.
Included Hex Driver
Jamb Anchor
Doorway Jamb with
Jamb Anchor
Doorway Jamb
Slide Doorway Jamb
against Jamb Anchor.
Hand tighten Set Screws in Doorway
Jamb evenly. Torque 1/8 turn past tight.
Doorway Jamb at Wall
(Assembled)
ULTRA NARROW
VERTICAL STILE
# 10 Fastener appropriate for substrate
JAMB ANCHOR
crlaurence.com | usalum.com
18
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
CLADDING INSTALLATION
Remove liner from VHB Tape and apply Cladding. Roll On Pressure = 15 Pounds Per Linear Inch.
Doorway Jamb at Sidelite
Doorway Jamb at Wall
Wall Jamb
Intermediate Mullion
Transom Header
Corner
NOTE: Apply Cladding to Header
before hanging doors.
Header
crlaurence.com | usalum.com
19
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TRANSOM DOOR INSTALLATION
1
4
6
8 3
1
3 8
Transom
5
4
Door
2
5
2
9
Transom Door Installation Order
1 Threshold and Top Track
Pages 10, 12
2 Transom Doorway Jambs
Page 21
3 Transom Vertical Jambs
Page 21
4 Transom Top Rail
Page 22
5 Transom Header
Page 22
6 Transom Glass
Page 23
7 Cladding
Page 19
8 Support Fins
Page 24
9 Door
Page 31
10 Finishing and Sealing
Page 32
1
1
2
3
3
2
TOP TRACK
6
TOP TRACK
Interior
8
FASTENING CLIPS
8
CUT SHORT
CENTER
ABOVE
THRESHOLD
TOP RAIL
TRANSOM
VERTICAL
JAMBS SIT ON
HEADER
HEADER
DOORWAY
JAMBS NOTCHED
FOR HEADER AND
TRANSOM VERTICALS
1. Follow instructions on Page 8 for Site Preparation, Page 10 for Threshold Installation, and Page 12 for
Top Track Installation.
crlaurence.com | usalum.com
20
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TRANSOM DOORWAY JAMB INSTALLATION
1. Install Doorway Jambs with notched ends at top, facing the door opening. See Pages 16-18 for mounting
options.
NOTCHED
END AT TOP
FACING
DOOR
OPENING
Exterior
TRANSOM VERTICAL
MAIN BODY
DOORWAY JAMB
Shown without Jamb
Anchor or glazing inserts.
See Pages 16-17 for options.
GASKET
Part No. GH342
TRANSOM VERTICAL
REMOVABLE STOP
Transom Vertical
(Assembled)
Doorway Jamb
(Notched)
NOTE: Doorway Jamb body only is shown in illustrations.
Doorway
Jamb
Doorway
Jamb
TRANSOM VERTICAL JAMB INSTALLATION
1. Align Transom Vertical Jamb Main Body with top of Doorway Jamb. Fasten with 10-24 X 3/4” Phillips
PHMS screws.
Align at top
Transom
Vertical
Transom
Verticals
Cladded side
faces interior
Doorway Jamb
Transom
Vertical
Doorway
Jamb
Secure with
10-24 X 3/4”
Phillips PHMS
ALIGN TO
TOP
TRANSOM VERTICAL
MAIN BODY
Cladded Side
GASKET
Part No. GH342
Doorway
Jamb
Doorway
Jamb
View from Interior
Transom Header aligns with
bottom notch. Transom Vertical
sits on Header.
crlaurence.com | usalum.com
21
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TRANSOM TOP RAIL INSTALLATION
1. Position Fastening Clips above holes in Top Rail and secure.
Fastening Clips
4” Sidelite Rail
Part No. 10X112HHDTEK
TRANSOM HEADER INSTALLATION
1. Attach Left and Right Support Fin Bottom Fittings to each end of Transom Header Main Body.
NOTE: Header ends are notched to accept Support Fins. Support Fins are installed on interior.
GASKET
Part No. GH342
TRANSOM HEADER
REMOVABLE STOP
Cladded Side
Exterior
Support Fin
Bottom Fitting Right
TRANSOM HEADER
MAIN BODY
Transom Header (Assembled)
Transom Header is
notched at both ends.
Part No. 10-16X3/4FHDSM
Support Fin
Bottom Fitting Left
2. Match holes on Doorway Jambs with holes of Support Fin Fitting and secure with screws.
Doorway Jamb
Transom Vertical
Transom Vertical
Transom Vertical
Transom Header
Transom Header
Part No. 10-16X3/4FHDSM
Transom Header
Views from Interior
Doorway Jamb
Doorway Jambs
crlaurence.com | usalum.com
Part No. 10-16X3/4FHDSM
22
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
TRANSOM GLASS INSTALLATION
1. Trim edges of the glass at face and sides
with a sharp utility knife to remove any
excess Silicone Sealant.
2. Place Setting Blocks 4” from each end of
Transom Header and Edge Blocks at quarter
points inside Transom Jamb Vertical pocket.
Transom Vertical Jamb
1/4
Transom Vertical Jamb
1/4
Neoprene Edge Block
1/4
1/4
1/4
1/4
1/4
1/4
Transom Header
4”
(101.6 mm)
4. Roll NP238 Gaskets into both sides of Top Rail
using a CRL Vinyl Roller.
3. Lift and set glass into pocket. Center.
2
4”
(101.6 mm)
1
Top Rail
Top Rail
Transom Glass
NP225 Gasket
Transom Header
Transom Glass
GASKET
Part No. NP238
3
Transom
Header
1/2” (5 mm)
Minimum Glass Bite
CRITICAL
Transom (Assembled)
5. Install Removable Stop for Header and then install Removable Stops for Transom Verticals. Secure with
screws at all predrilled hole locations.
Transom Vertical
Removable Stop
Transom Doorway
Vertical
Jamb
TRANSOM VERTICAL
REMOVABLE STOP
GASKET
Part No. GH342
TRANSOM VERTICAL
REMOVABLE STOP
Part No. 20092003
GASKET
Part No. GH342
Transom Vertical
Main Body
2
GASKET
2
Part No. GH342
Transom Header
Main Body
TRANSOM HEADER
REMOVABLE STOP
Part No.
20092003
Part No. 20092003
TRANSOM HEADER
REMOVABLE STOP
Transom Header
1
1
Transom Header
Removable Stop
crlaurence.com | usalum.com
View from Interior
23
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
SUPPORT FIN INSTALLATION
NOTE: Go to Page 19 to install Cladding before proceeding with the Support Fin installation.
Doorway Jamb
Sex Bolt
Shanks
Ceiling Fin Mounting Bracket
Sex Bolts
Vinyl Insert
Nylon Grommets
1/4” Flat Head Screws
Fasteners supplied by others
Gasket
Position Mounting Bracket flush against
cladded Doorway Jambs. Secure to ceiling.
Install Nylon Grommets in top holes
and slide glass into Mounting Bracket.
Secure.
Fitting Cover
Nylon Grommet
Gasket
Clamping Plate
Insert Nylon Grommet in bottom hole.
Position Clamping Plate and Gasket.
crlaurence.com | usalum.com
Sex Bolt
Shank
Sex Bolt
Secure.
Fitting Cover
Remove paper from Double Stick
Tape and apply Fitting Covers.
24
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
FIXED LITE INSTALLATION
1
1
3
3
1
Fixed Lite
44
2
44
5
Fixed Lite Installation Order
3
Fixed Lite
2
3
Pages 11, 12
2 Wall Jambs
Page 13
3 Top and Bottom Rail
Page 26
4 Fixed Lite Glass
Page 27
5 Intermediate Mullion
Page 28
6 Cladding
Page 19
7 Finishing and Sealing
Page 32
1
3
Fixed Lite
1
1
5
2
1 Sub Sill and Top Track
2
4
4
Exterior
Wall Jamb
Intermediate Mullion
Wall Jamb
TOP TRACK
FASTENING CLIPS
CUT SHORT
CENTER
DIRECTLY
OVER
FASTENING CLIPS
SUB SILL
INTERMEDIATE MULLION FITS
BETWEEN TOP AND BOTTOM RAILS
WALL JAMB
SITS ON
SUB SILL
WALL JAMB
SITS ON
SUB SILL
BOTTOM RAIL
SUB SILL
END DAMS
1. Follow instructions on Page 8 for Site Preparation and Pages 11-12 to install Sub Sill and center Top Track
above it. (Top Track is cut 1/2” (12.7 mm) short.)
2. Follow instructions on Page 13 to install Wall Jambs.
crlaurence.com | usalum.com
25
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
FIXED LITE TOP AND BOTTOM RAIL INSTALLATION
1. Attach Vertical Shear Clips at Intermediate
Mullion position on Top and Bottom Rails.
2. Position Fastening Clips above holes in
Top and Bottom Rails and secure.
TOP RAIL
Fastening Clips
4” Sidelite Rail
Part No. 10X112HHDTEK
Vertical Shear Clips
BOTTOM RAIL
Part No. 10X112HHDTEK
Do not block Drain Slots.
Vertical Shear Clips
Part No. 10X112HHDTEK
Fastening Clips
4” Sidelite Rail
Part No. 1GSR4SDU
crlaurence.com | usalum.com
26
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
FIXED LITE GLASS INSTALLATION
1. Trim edges of the glass at face and sides with
a sharp utility knife to remove any excess
Silicone Sealant.
2. Place Setting Blocks at quarter points in each
section of Bottom Rail and two Edge Blocks
inside each Wall Jamb Vertical pocket.
1/4
1/4
Neoprene Edge Blocks
1/4
1/4
1/4
1/4
Setting Blocks
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3. Lift and set each glass panel into pocket and center.
1
Fixed Lite
Glass
Fixed Lite
Glass
3
1/2” (5 mm)
Minimum Glass Bite
CRITICAL
2
4. Place Removable Stop on Wall Jamb Main Body and secure with screws at all predrilled hole locations.
Wall Jamb
Wall Jamb
Main Body
Wall Jamb
WALL JAMB
REMOVABLE STOP
Part No.
20092003
GASKET
Part No. GH342
GASKET
Part No. GH342
WALL JAMB
REMOVABLE STOP
Part No.
20092003
Interior
Part No.
20092003
Wall Jamb Removable Stop
crlaurence.com | usalum.com
27
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
INTERMEDIATE VERTICAL MULLION INSTALLATION
INTERMEDIATE MULLION
MAIN BODY
Exterior
GASKET
Part No. GH342
GASKET
GASKET
Part No. GH342
INTERMEDIATE MULLION
MAIN BODY
Part No. GH342
INTERMEDIATE MULLION
REMOVABLE STOP
INTERMEDIATE MULLION
REMOVABLE STOP
Part No.
20092003
1. Fit Vertical Mullion Main Body between Vertical
Mullion Shear Clips.
2. Fit Removable Stop and secure with screws at
all predrilled hole locations.
Intermediate Mullion
Main Body
Vertical
Shear Clips
Intermediate Mullion
Removable Stop
Intermediate Mullion
Main Body
Intermediate Mullion
Removable Stop
Vertical
Shear Clip
Part No.
20092003
Bottom Rail
Interior
Interior
3. Roll NP238 Gaskets into both sides of Top
and Bottom Rails using a CRL Vinyl Roller.
Top Rail
Gasket
Top Rail
Top Rail
Gasket
GASKET
Part No. NP238
Gasket
Gasket
Bottom Rail
Bottom Rail
Roll Gaskets into Rails
crlaurence.com | usalum.com
GASKET
Part No. NP238
Bottom Rail
Fixed Lite (Assembled)
28
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOUBLE DOOR WITH FRAME INSTALLATION
2
Door
Door
4
3
Double Door with Frame Installation Order
4
3
1 Threshold
Page 10
2 Header
Page 12
3 Doorway Jambs
Page 18
4 Cladding
Page 19
5 Door
Page 31
6 Finishing and Sealing
Page 32
1
3
3
2
4
4
Exterior
Doorway Jamb
at Wall
Doorway Jamb
at Wall
Exterior
1
Door
crlaurence.com | usalum.com
29
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
OPTIONAL CORNER INSTALLATION
1. Install Mitered Sub Sill and Top Track above.
2. Install Corner Main Body and Wall or Doorway Jambs on either side of it.
Corner (Assembled)
SUB SILL
GASKET
Part No. GH342
CORNER
REMOVABLE STOP
SUB SILL
CORNER
MAIN BODY
CORNER
SITS ON MITERED
SUB SILL
Interior
GASKET
Part No. GH342
3. Install Top and Bottom Sidelite Rails with Corner Shear Clips next to Corner Main Body.
TOP SIDELITE RAIL
BOTTOM SIDELITE RAIL
Corner Shear Clip
attaches to Corner
Corner Shear Clip
attaches to Corner
4. Prepare and install glass panels. Fit Removable Stops and secure with screws at all predrilled hole
locations.
GASKET
Part No. GH342
Corner
Removable Stop
Corner
Main Body
CORNER
REMOVABLE STOP
Part No.
20092003
GASKET
Part No. GH342
Top Rail
crlaurence.com | usalum.com
30
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
DOOR INSTALLATION
The doors for the Entice System are shipped fully assembled. Because of the weight of both the aluminum
and the glass, it is advisable that two individuals are involved in moving and installing this door.
NOTE: Installation varies with hardware selection. Consult Installation Instructions in hardware packages.
Use included T-Handle Key to turn the adjustment screws on the top and bottom of the hinge side of the door.
With the door open, turn clockwise to adjust the Door Rail away from the jamb and counter-clockwise to
adjust the Door Rail towards the jamb. Make sure the gaps are parallel and the correct size.
NOTE: A slight clicking noise may be heard. This sound is caused by our friction retention mechanism that
will help prevent the screw from loosening out of alignment.
CENTER PIVOT DOORS:
To center the door, loosen the two Pan Head Phillips Screws holding the arm to the block, then adjust the two
hex bolts at the end of each arm to slightly change the angle of the arm as it mounts in the Door Rail. Make
sure that both hex bolts are tightened against the inside face of the Door Rail, and the two Pan Head Phillips
Screws are tightened to the block when adjustment is complete to secure the adjustments into place.
crlaurence.com | usalum.com
31
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
PERIMETER SEALING
1. Seal around Doorway Jamb at Threshold.
2. Seal joints between Bottom Rail and
Sub Sill inside and outside.
Seal around Doorway Jamb at notched
Threshold with Cat. No. 33S Clear Silicone.
Bottom Rail
Doorway Jamb
Cat. No. 33S Clear
Cat. No. 95C Black
Cat. No. 33S Clear
Shim
Sub Sill
Backer Rod
Cat. No. 95C Black
Threshold
3. Install Backer Rod and seal perimeter with Cat. No. 95C
Silicone Sealant at all shimmed areas inside and outside.
Cat. No. 95C Black
4. Seal interior perimeter at all verticals 2”
(203 mm) up from ground where they
meet Bottom Rails.
Doorway Jamb
Cat. No. 95C Black
Wall Jamb
.8
(50
2”
Backer Rod
Backer Rod
Wall Jamb
Cat. No. 95C Black
.8
(50
2”
Doorway Jamb
at Wall
Cat. No. 95C Black
)
mm
)
mm
Cat. No. 33S Clear
Interior
Cat. No. 33S Clear
5. Seal outside bottom corners where all verticals meet Bottom Rails.
Doorway Jamb
Wall Jamb
Intermediate Mullion
Cat. No. 33S Clear
Cat. No. 33S Clear
Bottom Rail
Exterior
Bottom Rail
crlaurence.com | usalum.com
Cat. No. 33S Clear
Cat. No. 33S Clear
Bottom Rail
Exterior
32
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
GLASS REPLACEMENT FOR DOORS
REMOVE DAMAGED GLASS
Support door on sturdy sawhorses.
Remove door handles and panic or exit
devices and store in a safe place.
Loosen Set Screws on both sides of Vertical Stiles.
Remove Socket Head Cap Screws from each corner.
crlaurence.com | usalum.com
NOTE: Handle Cladding
with care so as to not
bend or scratch it.
Remove Cladding from both sides of Vertical Stiles.
Back out Clamping Screws on Top and Bottom Rails.
Remove Vertical Stiles and Top and Bottom Rails. If
Gaskets are not in good condition, remove them. If
replacing Top and Bottom Rail Cladding, do so now.
33
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
INSTALL REPLACEMENT GLASS
Verify replacement glass size and
mounting hole placement for handles.
Place Top and Bottom Rails and tighten Clamping Screws.
NOTE: Ensure Rails are properly supported until secured to Vertical Stiles.
Vertical Stile
Install replacement gasket
Clamping Strip
Gasket Housing
Replace Gaskets in Vertical Stiles if needed.
Spray glass edges with Cat. No. 1973 to prevent Gaskets from
binding and install Vertical Stiles.
Blue Loctite
NOTE: The Vertical Stiles may be installed as
three separate pieces. First apply the Clamping
Strip to the glass, then fit the Gasket Housing
over it and finally slide the Vertical Stile over it.
This works well with oversized glass thickness.
Ensure Stiles
are Straight
Apply Blue Loctite to Socket Head Cap Screws
and fasten Vertical Stiles to Top and Bottom Rails.
Hinge Side
Vertical Stile
Rubber Setting Block
inside Bottom Rail
Ensure Bottom Rail
is tight against glass
Push frame at bottom to ensure Setting Block is in contact
with glass. Ensure Bottom Rail is tight against glass and
Vertical Stiles are straight.
crlaurence.com | usalum.com
Tighten Set Screws evenly on Hinge Side of
the Vertical Stiles. Torque 1/8 turn past tight.
34
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
INSTALL REPLACEMENT GLASS (CONTINUED)
Measure Diagonally
Use Adjuster
to raise Handle
Side corner
Handle Side
Vertical Stile
1/8”
(3.2 mm)
Turn Adjuster in Top Rail on Handle Side clockwise until it contacts
glass. Measure diagonally to corners. If needed, turn Adjuster again
to raise corner a maximum of 1/8” (3.2 mm) until door is square.
Tighten Set Screws evenly on Handle Side of
the Vertical Stiles. Torque 1/8 turn past tight.
Measure Between Stiles
1
ER
23
CK
24
LO
AD
2
24
RE
TH
Blue Loctite
Measure between Vertical Stiles near Bottom Rail
and again at middle to ensure Stiles are straight.
Apply Blue Loctite on all attachment
fasteners and install door handles.
Follow instructions on
Page 30 to install and
adjust door.
Use Adjuster to
raise Handle
Side corner
1/8”
(3.2 mm)
NOTE: If Handle Side sags, loosen Set Screws and
turn Adjuster to raise. Then tighten Set Screws.
crlaurence.com | usalum.com
Remove liner from VHS Tape and
apply Cladding to Vertical Stiles.
Roll On Pressure = 15 Pounds Per Linear Inch
35
ALUMINUM
ENTICE SERIES ENTRANCE SYSTEMS INTERIOR GLAZE
JOB SITE ESSENTIALS
ALUMINUM
Helpful Tools and Supplies for Installing CRL U.S. Aluminum
Entrances, Storefronts, Windows, and Curtain Wall Systems
CRL 95C Silicone
Building Sealant
CAT. NO. 95C
CRL RTV408 Neutral
Cure Silicone
CAT. NO. RTV408
CRL33S Silicone
Sealant
CAT. NO. 33S
CRL12:1 Ratio Strap
Frame Caulking Gun
CAT. NO. GA1203
CRL Complete Set of Seven
All Stainless Steel Spatulas
CAT. NO. AB958G
CRL Open Cell
Backer Rod
CAT. NO. B0CBR58C
CRL Backer Rod
Roller Tool
CAT. NO. SBRR
CRL Glass Cleaner
CAT. NO. 1973
CRL Glass Wipes
CAT. NO. 1550
CRL Clear Loctite® Poxy-Pak™ TwoPart Epoxy
CAT. NO. 81120
CRL 1.69 Fl. Oz. (50 ml) Bottle
Loctite® Threadlocker
CAT. NO. 24231
CRL Plumb Bob Alignment Tool for
Premium Balanced Doors
CAT. NO. BDPS105
crlaurence.com | usalum.com
36
ALUMINUM