13.01 Econometer Rev1.02 A4.cdr

Transcription

13.01 Econometer Rev1.02 A4.cdr
Econometer System
Mega-Guard ES:
Econometer System
8,4" Operator Panel
Torque, power and speed
Fuel consumption absolute (L/Hr, GAL/Hr, T/Hr)
Fuel consumption specific (Nm)
Optional GPS speed log (SOG)
Voyage cumulative
Trip based logging
IMO legislation SEEMP
Power supply voltage: 19~32Vdc
World wide service network
Class type approved
YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION
Econometer
Features
8,4" TFT Operator Panel with Value Mode
The Mega-Guard Econometer
System (ES) measures and
displays the actual fuel
consumption with the actual
power delivered. In addition,
the fuel consumption is totalized
and available to be loaded on
USB stick. The Econometer
System helps to realize IMO
legislation SEEMP (Ship Energy
Efficiency Management Plan).
The Econometer System (ES)
has the following system
features:
Continuous Torque, power
and speed measurement
Calculation of absolute and
relative fuel consumption
History data recording and
display capability
History data retrieval via
USB- or Ethernet file
transfer
Optional NMEA or
MODBUS interface to
external system
Value Mode
8,4" TFT Operator Panel with Graphic Mode
The TFT screen is displaying
a set of data on a mimic.
The user can choose out off
different datasets displaying
power, torque and speed data
on the mimic. For multiple
engine or shaft configuration,
each engine or shaft data may
be displayed at the same time
or separately.
Torque, power and speed
Fuel consumption
(l/hr, GPH, t/hr)
Fuel consumption per NM
GPS speed (SOG)
Voyage cumulative
This mode also includes
controls for trip based logging.
2
Fuel efficiency measurement
Graph Mode
1
Engine 1
Flow Meter 1
(4-20mA)
Engine 1
Torque Meter
(4-20mA)
13 B
2
Engine 1
Flow Meter 2
(4-20mA)
Engine 1
Generator
(4-20mA)
14 B
3
Engine 2
Flow Meter 1
(4-20mA)
Engine 2
Torque Meter
(4-20mA)
15B
4
Engine 2
Flow Meter 2
(4-20mA)
Engine 2
Generator
(4-20mA)
16 B
5
Engine 3
Flow Meter 1
(4-20mA)
Engine 3
Torque Meter
(4-20mA)
17 B
6
Engine 3
Flow Meter 2
(4-20mA)
Engine 3
Generator
(4-20mA)
18 B
98.6.034.800
X011
7
Engine 4
Flow Meter 1
(4-20mA)
Engine 4
Torque Meter
(4-20mA)
19 B
8
Engine 4
Flow Meter 2
(4-20mA)
Engine 4
Generator
(4-20mA)
20 B
9
Engine 5
Flow Meter 1
(4-20mA)
Engine 5
Torque Meter
(4-20mA)
21 B
B 10
Engine 5
Flow Meter 2
(4-20mA)
Engine 5
Generator
(4-20mA)
22 B
Engine 6
Flow Meter 1
(4-20mA)
Engine 6
Torque Meter
(4-20mA)
23 B
Engine 6
Flow Meter 2
(4-20mA)
Engine 6
Generator
(4-20mA)
24 B
A
B
C
A
B
C
A
B
C
A
B
C
A
Stat Mode
B
C
A
The Stat screen gives access to calculated statistics for the torque, power, speed
and fuel consumption data. The system presents the average (AVG), maximum (MAX),
and minimum (MIN) values for the last minute, the last hour or the last day.
B
C
A
B
C
A
B
C
A
B
Configuration screen
C
A
C
The Configuration screen allows the user to view the configuration status, to change the
system configuration, to transfer data and to access the sensor calibration mode.
A
B 11
C
A
B 12
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
24 channel Analog and Digital Input I/O Module
In graph mode, the TFT screen displays a chart style graph showing the evolution of
one user selected data (torque, power, speed, absolute or relative fuel consumption)
over time.
C
A
C
System Hardware
Shaft Torque Meter
- Optical measuring principle
- Extreme accuracy of optical sensor
- Wireless transmission of data and power
Fuel oil Flow Meter
- Capacity from 120 to 380 l/min, continous max.
- Measuring accuracy +/- 0.2%
- PT100 output for temperature compensation
3
Flow meter 4~20mA
24 channel Analog and Digital Input I/O Module
- Dimensions: L=198mm, W=127mm, H=29mm
- LED alarm indicator and text window for each channel
- 32 bit ARM CPU
- 24 analog or digital input channels with software selectable input ranges
- Galvanic isolation of input to internal logic and to external modules
- I/O Connector including power supply input
- Earth fault detection on inputs
- Out of range , open circuit and short circuit detection on inputs
- Power consumption: 15W
Torque meter 4~20mA
8.4” Colour Graphic TFT with 12 pushbuttons
- Dimensions: L=240mm, W=160mm, H=51mm
- 12 configurable pushbuttons
- NMEA input (RS485)
- Optional MODBUS or NMEA output (RS485)
- USB maintenance port
- Power supply 24Vdc
- Power consumption: 15W
Mega-Guard Econometer System
Bridge Console Front
8,4"
Operator Panel
19~32Vdc Main
I/O Cable
1
Engine 1
Flow Meter 1
(4-20mA)
Engine 1
Torque Meter
(4-20mA)
13 B
2
Engine 1
Flow Meter 2
(4-20mA)
Engine 1
Generator
(4-20mA)
14 B
3
Engine 2
Flow Meter 1
(4-20mA)
Engine 2
Torque Meter
(4-20mA)
15B
4
Engine 2
Flow Meter 2
(4-20mA)
Engine 2
Generator
(4-20mA)
16 B
5
Engine 3
Flow Meter 1
(4-20mA)
Engine 3
Torque Meter
(4-20mA)
17 B
6
Engine 3
Flow Meter 2
(4-20mA)
Engine 3
Generator
(4-20mA)
18 B
98.6.034.800
X011
7
Engine 4
Flow Meter 1
(4-20mA)
Engine 4
Torque Meter
(4-20mA)
19 B
8
Engine 4
Flow Meter 2
(4-20mA)
Engine 4
Generator
(4-20mA)
20 B
9
Engine 5
Flow Meter 1
(4-20mA)
Engine 5
Torque Meter
(4-20mA)
21 B
B 10
Engine 5
Flow Meter 2
(4-20mA)
Engine 5
Generator
(4-20mA)
22 B
Engine 6
Flow Meter 1
(4-20mA)
Engine 6
Torque Meter
(4-20mA)
23 B
Engine 6
Flow Meter 2
(4-20mA)
Engine 6
Generator
(4-20mA)
24 B
Bridge Console Inside
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
C
A
B 11
C
A
B 12
Sensors
C
Torque
Sensor
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
A-In
I/O Module
C
A
C
A
C
A
C
A
C
Flow
Meter 1
Flow
Meter 2
GPS
(speed)
optional
Mega-Guard Ship Automation and Navigation System
Alarm Monitoring
and Control System
Valve Control and
Monitoring System
Power
Management System
Propulsion
Control System
Econometer
System
Dynamic
Positioning System
Integrated
Bridge System
Heading
Control System
Fire
Alarm System
BNWAS
Watch Alarm System
Alarm and
Monitoring System
Navigation Light and
Window Wiper System
Branch offices:
Head office:
Praxis Automation China
Praxis Automation Technology B.V.
Zijldijk 24A, 2352 AB Leiderdorp, The Netherlands
+31 (0)71 5255 353
+31 (0)71 5224 947
[email protected]
www.praxis-automation.com
Praxis Automation Korea
Your representative:
Praxis Automation Singapore
Praxis Automation India
YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION

Similar documents

Technical details - Andofe Shipping Management

Technical details - Andofe Shipping Management Marine Equipments PTE Ltd – Singapore One set Capacity 200MT, height above deck 700 mm,

More information