13.01 Econometer Rev1.02 A4.cdr
Transcription
13.01 Econometer Rev1.02 A4.cdr
Econometer System Mega-Guard ES: Econometer System 8,4" Operator Panel Torque, power and speed Fuel consumption absolute (L/Hr, GAL/Hr, T/Hr) Fuel consumption specific (Nm) Optional GPS speed log (SOG) Voyage cumulative Trip based logging IMO legislation SEEMP Power supply voltage: 19~32Vdc World wide service network Class type approved YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION Econometer Features 8,4" TFT Operator Panel with Value Mode The Mega-Guard Econometer System (ES) measures and displays the actual fuel consumption with the actual power delivered. In addition, the fuel consumption is totalized and available to be loaded on USB stick. The Econometer System helps to realize IMO legislation SEEMP (Ship Energy Efficiency Management Plan). The Econometer System (ES) has the following system features: Continuous Torque, power and speed measurement Calculation of absolute and relative fuel consumption History data recording and display capability History data retrieval via USB- or Ethernet file transfer Optional NMEA or MODBUS interface to external system Value Mode 8,4" TFT Operator Panel with Graphic Mode The TFT screen is displaying a set of data on a mimic. The user can choose out off different datasets displaying power, torque and speed data on the mimic. For multiple engine or shaft configuration, each engine or shaft data may be displayed at the same time or separately. Torque, power and speed Fuel consumption (l/hr, GPH, t/hr) Fuel consumption per NM GPS speed (SOG) Voyage cumulative This mode also includes controls for trip based logging. 2 Fuel efficiency measurement Graph Mode 1 Engine 1 Flow Meter 1 (4-20mA) Engine 1 Torque Meter (4-20mA) 13 B 2 Engine 1 Flow Meter 2 (4-20mA) Engine 1 Generator (4-20mA) 14 B 3 Engine 2 Flow Meter 1 (4-20mA) Engine 2 Torque Meter (4-20mA) 15B 4 Engine 2 Flow Meter 2 (4-20mA) Engine 2 Generator (4-20mA) 16 B 5 Engine 3 Flow Meter 1 (4-20mA) Engine 3 Torque Meter (4-20mA) 17 B 6 Engine 3 Flow Meter 2 (4-20mA) Engine 3 Generator (4-20mA) 18 B 98.6.034.800 X011 7 Engine 4 Flow Meter 1 (4-20mA) Engine 4 Torque Meter (4-20mA) 19 B 8 Engine 4 Flow Meter 2 (4-20mA) Engine 4 Generator (4-20mA) 20 B 9 Engine 5 Flow Meter 1 (4-20mA) Engine 5 Torque Meter (4-20mA) 21 B B 10 Engine 5 Flow Meter 2 (4-20mA) Engine 5 Generator (4-20mA) 22 B Engine 6 Flow Meter 1 (4-20mA) Engine 6 Torque Meter (4-20mA) 23 B Engine 6 Flow Meter 2 (4-20mA) Engine 6 Generator (4-20mA) 24 B A B C A B C A B C A B C A Stat Mode B C A The Stat screen gives access to calculated statistics for the torque, power, speed and fuel consumption data. The system presents the average (AVG), maximum (MAX), and minimum (MIN) values for the last minute, the last hour or the last day. B C A B C A B C A B Configuration screen C A C The Configuration screen allows the user to view the configuration status, to change the system configuration, to transfer data and to access the sensor calibration mode. A B 11 C A B 12 C A C A C A C A C A C A C A C A C A C A C A 24 channel Analog and Digital Input I/O Module In graph mode, the TFT screen displays a chart style graph showing the evolution of one user selected data (torque, power, speed, absolute or relative fuel consumption) over time. C A C System Hardware Shaft Torque Meter - Optical measuring principle - Extreme accuracy of optical sensor - Wireless transmission of data and power Fuel oil Flow Meter - Capacity from 120 to 380 l/min, continous max. - Measuring accuracy +/- 0.2% - PT100 output for temperature compensation 3 Flow meter 4~20mA 24 channel Analog and Digital Input I/O Module - Dimensions: L=198mm, W=127mm, H=29mm - LED alarm indicator and text window for each channel - 32 bit ARM CPU - 24 analog or digital input channels with software selectable input ranges - Galvanic isolation of input to internal logic and to external modules - I/O Connector including power supply input - Earth fault detection on inputs - Out of range , open circuit and short circuit detection on inputs - Power consumption: 15W Torque meter 4~20mA 8.4” Colour Graphic TFT with 12 pushbuttons - Dimensions: L=240mm, W=160mm, H=51mm - 12 configurable pushbuttons - NMEA input (RS485) - Optional MODBUS or NMEA output (RS485) - USB maintenance port - Power supply 24Vdc - Power consumption: 15W Mega-Guard Econometer System Bridge Console Front 8,4" Operator Panel 19~32Vdc Main I/O Cable 1 Engine 1 Flow Meter 1 (4-20mA) Engine 1 Torque Meter (4-20mA) 13 B 2 Engine 1 Flow Meter 2 (4-20mA) Engine 1 Generator (4-20mA) 14 B 3 Engine 2 Flow Meter 1 (4-20mA) Engine 2 Torque Meter (4-20mA) 15B 4 Engine 2 Flow Meter 2 (4-20mA) Engine 2 Generator (4-20mA) 16 B 5 Engine 3 Flow Meter 1 (4-20mA) Engine 3 Torque Meter (4-20mA) 17 B 6 Engine 3 Flow Meter 2 (4-20mA) Engine 3 Generator (4-20mA) 18 B 98.6.034.800 X011 7 Engine 4 Flow Meter 1 (4-20mA) Engine 4 Torque Meter (4-20mA) 19 B 8 Engine 4 Flow Meter 2 (4-20mA) Engine 4 Generator (4-20mA) 20 B 9 Engine 5 Flow Meter 1 (4-20mA) Engine 5 Torque Meter (4-20mA) 21 B B 10 Engine 5 Flow Meter 2 (4-20mA) Engine 5 Generator (4-20mA) 22 B Engine 6 Flow Meter 1 (4-20mA) Engine 6 Torque Meter (4-20mA) 23 B Engine 6 Flow Meter 2 (4-20mA) Engine 6 Generator (4-20mA) 24 B Bridge Console Inside A B C A B C A B C A B C A B C A B C A B C A B C A B C A C A B 11 C A B 12 Sensors C Torque Sensor A C A C A C A C A C A C A C A A-In I/O Module C A C A C A C A C Flow Meter 1 Flow Meter 2 GPS (speed) optional Mega-Guard Ship Automation and Navigation System Alarm Monitoring and Control System Valve Control and Monitoring System Power Management System Propulsion Control System Econometer System Dynamic Positioning System Integrated Bridge System Heading Control System Fire Alarm System BNWAS Watch Alarm System Alarm and Monitoring System Navigation Light and Window Wiper System Branch offices: Head office: Praxis Automation China Praxis Automation Technology B.V. Zijldijk 24A, 2352 AB Leiderdorp, The Netherlands +31 (0)71 5255 353 +31 (0)71 5224 947 [email protected] www.praxis-automation.com Praxis Automation Korea Your representative: Praxis Automation Singapore Praxis Automation India YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION
Similar documents
Technical details - Andofe Shipping Management
Marine Equipments PTE Ltd – Singapore One set Capacity 200MT, height above deck 700 mm,
More information