OPERATING RANGES 70 m CE Manometric heads of up to: HORIZONTAL Stainless steel MULTISTAGE PUMPS 2 pole - 50 Hz 10 bar Max. operating pressure: 6 bar Max. intake pressure: Temperature range: MULTI-H 25 m3/h Flow rates of up to: Max. ambient temperature: – 15° to + 110°C + 40°C DN (nominal diameter) of ports: G11/4 to G2 APPLICATIONS 240 70 H m MULTi-H 0 MULTi-V 25 3 Qm/h 48 Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors: - Supply - Boosting - Watering - Irrigation - Washing stations - Drainage -Filling (pools, swimming pools...) - Heating - Air conditioning - Water treatment (demineralisation, filtration...) And for incorporation into all modular systems. Abstraction from wells, springs, rivers, ponds... Pumped fluids • 304 range: clear and non-corrosive liquids (drinking water, glycol water...). • 316L range: corrosive liquids (demineralised seawater, chlorinated water...). ADVANTAGES EFFICIENCY / RELIABILITY • IE2 motor. • Optimal reliability: high outputs thanks to the impeller profile, which reduces the number of stages, the sizes of the shafts and the axial thrusts. • S tainless steel hydraulic assembly: protection from corrosion and extended pump life. • Suction rings between very thick cells: impervious to thermal expansion and eliminates the risk of seizing. INSTALLATION • C ompact pump of one-piece design, requires little space and performs economically and quietly. • Easy installation. Certified • MULTI-H with three-phase motor • MULTI-H with single-phase motor MAINTENANCE • S tandardised mechanical seal withstands max. temperatures of +110°C without any maintenance. • Motor bearing fitted in the front shroud generously dimensioned and leak-tight. • ALL STAINLESS STEEL hydraulic assembly N.T. No 141-1/ENG. - Ed. 11/10-14 1 MULTI-H DESIGN HYDRAULIC PRESELECTION RANGE • Hydraulic part ALL Stainless steel - Horizontal, centrifugal, not self-priming. - Multi-stage, 2 to 6 stages. - A xial intake and vertical, upward delivery. - Impellers fitted directly onto the extended motor shaft. - Standardised mechanical seal ensures leaktightness of shaft passage. - Hydraulic assembly fixed to a lantern ring at 8 points. • Motor - IE2 standard ventilated - With extended shaft end - Single-phase motor with integrated thermal protection and automatic reset; capacitor integrated into the terminal box. - Rotor-shaft guide bearings lubricated for life. Rotation speed: Three-phase winding: Single-phase: Frequency: Insulation class: Protection class: 2900 rpm 230-400 V 230 V 50 Hz (optional 60 Hz) 155 (F) IP 54 BASIC CONSTRUCTION Main parts Corrosive liquids* Housing casing S steel 304 S steel 316 L Impellers S steel 304 S steel 316 L Pump shaft Cell centring device Mechanical seal O-rings Plugs Attachment support bearing S steel 304 S steel 316 L S steel 316 L S steel 316 L S steel 304 S steel 316 L Carbon/ Ceramic Tungsten carbide/ Carbon Ethylene Propylene EPDM VITON S steel 316L S steel 316 L Aluminium Aluminium * Except for MULTi-H1600 serie NOTA : 304 (X2CrNiMo 17.12.2) or 316 L (X2CrNiMo17-12) stainless steel - recommended materials offering excellent corrosion resistance. Clean and clear liquids with no fibres and low sand/silica content (max. concentration 40 g/m3). 2 15 20 30 40 50 Hm Hft MULTi-H 70 50Hz 200 60 50 150 40 100 30 MULTi-H800 MULTi-H200 75 20 MULTi-H1600 MULTi-H400 15 10 Qm3/h 1 2 Ql/min 30 Ql/s 0,5 3 40 4 50 70 1 IDENTIFICATION MULTi-H 206 N -S E - M X V - T Material Non-corrosive liquids Cells (stage housing) 10 Imp.gpm Pump code HORIZONTALE MULTI-STAGE STAINLESS STEEL Nominal flowrate in m3/h Number of stages IE2 motor S: S steel 304 X: S steel 316L E : EPDM V : VITON T: three-phase motor M: single-phase motor 5 6 8 100 1,5 10 150 2 25 200 3 400 4 50 MULTI-H SECTIONAL DIAGRAM 1111 9621A 4610A 2510 1160 1154 1150 4213 4610C 9902 9825A 3180 9826A G 1"1/2 9906 9842 3011A 9842 9944 G 2" 9940 9822 9831 9922 2410A 4610B 9621B MECHANICAL SEAL 2410B 2250 2520 6545 2460B 4220 4240 2540 PARTS LIST 1111 - Housing • 1150 - Stage housing with interstage crossover • 1154 - Stage housing centring device • 1160 - Stage housing without interstage crossover • 2250 - Impeller 2410 - Impeller spacer 2460 A - Impeller thickness washer 2460 B - Mechanical seal spacer 2520 - Impeller support ring-snap ring 2540 - Deflector 2911 - Shaft end washer • 3011 A - Rolling bearing fan side • 3011 B - Rolling bearing pump side • 3134 - Motor mounting base 3180 - Lantern ring 4213 - Throat bushing casing • 4220 - Rotating part | Seal | Mechanical • 4240 - Fixed part • 4610 A - O-ring (filler plug) • 4610 B - O-ring (drain plug) • 4610 C - O-ring (lantern ring housing) 3011B 6545B 6515 6521 • 6545 6571 • 8110 • 9220 • 9460 • 9820 9822 • 9825 • 9831 • 9860 9902 A 9902 B 9902 C 9942 9944 9966 8110 3134 9903B 6571 - Drain plug - Bleeding and filling plug - Snap ring (support ring) - Motor assembly stud bolt - Electric motor housing - Rotor shaft - Terminal cover gasket - Fan - Fan housing - Motor terminal cover - Rear motor bearing - Capacitor - Lantern ring housing attachment screw - Shaft end screw - Cleaning screw - External tooth lock washer - Spring washer - Elastic pin (•) Recommended spare parts. 3 MULTI-H HYDRAULIC PERFORMANCE – SERIES 200 AND 400 - 2 POLE 80 0 5 10 Imp.gpm 15 MULTi-H200 Hm 50Hz 0 Hft 206 70 205 50 10 15 20 Imp.gpm 25 MULTi-H400 Hm 50Hz 200 60 405 50 150 204 40 150 404 40 203 100 30 403 100 30 202 402 20 20 50 10 10 1 % η% 30 2 3 4 Qm3/h 5 5) (20 NPSH (205) 10 0 1 2 3 4 Qm3/h 5 P kW % 205 0,6 204 203 0,4 1 0 0 0 10 2 20 30 0,5 3 40 50 4 60 1 80 20 0 0 3 4 5 6 7 8 Qm3/h 5) (40 η% 40 2 2 2 NPSH (405) 0 1 2 3 4 5 6 7 8 Qm3/h 1,2 406 0,9 405 404 403 402 0,3 Qm3/h 5 70 1 0,6 202 0,2 0 P kW 206 0,8 4 0 4 20 0,0 0 NPSH m 0 40 0 50 NPSH m 0 Hft 406 70 200 60 5 Ql/min 1,5 Ql/s 0,0 0 1 2 3 4 5 6 7 0 30 60 90 120 0 5 10 15 20 8 Qm3/h Ql/min Ql/s 0 MULTI-H HYDRAULIC PERFORMANCE – SERIES 800 AND 1600 - 2 POLE Imp.gpm 70 10 20 30 40 50 Hm 805 50 60 80 100 Hft 50Hz 55 50Hz 60 40 MULTi-H1600 MULTi-H800 Hm Imp.gpm 20 50 180 160 1604 45 804 140 40 40 803 1603 35 30 120 100 30 802 20 25 1602 80 20 60 10 15 40 0 10 0 2 4 6 8 10 12 80 60 η% 40 ) (802 20 0 NPSH m 0 2 4 8 6 4 2 NPSH (802) 6 8 10 12 Qm3/h 2 P2 kW 0 0 80 8 % 12 16 20 24 28 NPSH 603) η % (1 0 32 m 6 4 40 NPSH 1604 20 1,5 Qm 3 /h 4 8 2 12 16 20 24 28 32 0 kW 1,25 2,5 1 2,0 0,75 1,5 0,5 1,0 0,25 0,5 0 Qm 3 /h 4 60 0 1,75 20 5 Qm3/h 0 Ql/min Ql/s 2 50 21 4 6 100 8 2 150 10 12 200 3 Qm3/h 0 1604 1603 1602 Qm 3 /h 4 Ql/min Ql/s 8 100 12 16 200 2 20 24 300 4 400 6 28 32 500 8 5 MULTI-H SECTIONAL VIEW OF THE INSTALLATION • Suction pump MIN. Max. suction heads (Ha) and min. flooded heads (Hc) at the pump’s nominal flowrate. Niveaulevel haut High Fluid temperature Ha MULTi-H 200 MULTi-H 400/800/1600 Ha mCL Hc mCL Ha mCL Hc mCL + 20°C 7 --- 7 --- + 50°C 6 --- 6 --- + 80°C 2,2 --- 3 --- +110°C --8,1 --7 These values do not take account of losses of head in the suction pipe. Niveau bas Low level min. 0,70m Clapet de foot pied de crépine Strainer valve 0,10m • Flooded suction pump on storage tank or mains water system (with low water protection kit) Strainer Crépine Hc Mains supply Réseauwater de ville 6 MULTI-H ELECTRICAL DATA AND DIMENSIONS Filling L3 L5 DNA DN H1 H 104 Ø1 4 L4 Draining Ø1 4 Ø9 L1 L2 108 L MULTI-H202-SE-M MULTI-H202-SE-T MULTI-H203-SE-M MULTI-H203-SE-T MULTI-H204-SE-M MULTI-H204-SE-T MULTI-H205-SE-M MULTI-H206-SE-M MULTI-H402-SE-M MULTI-H402-SE-T MULTI-H403-SE-M MULTI-H403-SE-T MULTI-H404-SE-M MULTI-H405-SE-M MULTI-H406-SE-M MULTI-H802-SE-M MULTI-H803-SE-M MULTI-H804-SE-M ORDER REFERENCE COMMANDE REFERENCE masse mass MOTEUR MOTOR POMPE PUMP P2 Condensateur Orifices Capacitor Suction Orifices Ports H H1 H2 L L1 L2 L3 L4 L5 Rendement P2 Efficiency according Facteur Power vitesse tension moteur Speed motor voltage asp. ports. ref. selon charge (%) puissance to load (%) factor kW 4/4 3/4 2/4 µF DNA DNR mm mm mm mm mm mm mm mm mm kg Tr/min cos φ rpm 1x230 V 3x230 V 3x400 V 0,55 0,76 2860 4 – – 12 1 1 216 90 104 375 204 95 109,5 51 106 9,8 0,55 0,76 2860 – 3 1,7 – 1 1 192 90 104 375 204 95 109,5 51 106 8,9 0,55 0,76 2860 4 – – 12 1 1 216 90 104 375 204 95 109,5 51 106 9,8 0,55 0,76 2860 – 3 1,7 – 1 1 192 90 104 375 204 95 109,5 51 106 8,9 0,55 0,76 2860 4 – – 12 1 1 216 90 104 423 252 95 157,5 51 106 10,6 0,55 0,76 2860 – 3 1,7 – 1 1 192 90 104 423 252 95 157,5 51 106 9,7 0,75 79 78 76 0,82 2850 5,1 – – 16 1 1 216 90 104 423 252 95 157,5 51 106 12,2 1,1 80,5 80,5 78,0 0,82 2850 7,2 – – 30 1 1 224 90 104 472 276 103,5 181,5 51 106 15,7 0,55 0,76 2860 4 – – 12 1¼ 1 216 90 104 375 204 95 109,5 51 106 9,8 0,55 0,76 2860 – 3 1,7 – 1¼ 1 192 90 104 375 204 95 109,5 51 106 8,9 0,55 0,76 2860 4 – – 12 1¼ 1 216 90 104 375 204 95 109,5 51 106 10,7 0,55 0,76 2860 – 3 1,7 – 1¼ 1 192 90 104 375 204 95 109,5 51 106 9,8 0,75 79 78 76 0,82 2850 5,1 – – 16 1¼ 1 216 90 104 423 252 95 157,5 51 106 12,2 1,1 80,5 80,5 78,0 0,82 2850 7,2 – – 30 1¼ 1 224 90 104 448 252 103,5 157,5 51 106 15,2 1,5 82 82 80 0,77 2900 9,2 – – 40 1¼ 1 224 90 104 472 276 103,5 181,5 51 106 17,8 2850 5,1 – – 16 0,75 79 78 76 0,82 1½ 1¼ 216 90 104 387 216 95 121,5 51 106 15,8 1,1 80,5 80,5 78,0 0,82 2850 7,2 – – 30 1½ 1¼ 224 90 104 412 216 103,5 121,5 51 106 14,5 1,5 82 82 80 0,77 2900 9,2 – – 40 1½ 1¼ 224 90 104 472 276 103,5 181,5 51 106 16 P2 kW MULTI-H205N-SE-T MULTI-H206N-SE-T MULTI-H404N-SE-T MULTI-H405N-SE-T MULTI-H406N-SE-T MULTI-H802N-SE-T MULTI-H803N-SE-T MULTI-H804N-SE-T MULTI-H805N-SE-T MULTI-H1602N-SE-T MULTI-H1603N-SE-T MULTI-H1604N-SE-T 0,75 1,1 0,75 1,1 1,1 0,75 1,1 1,5 2,2 1,5 2,2 2,2 MOTEUR MOTOR Rendement Efficiency according selon Facteur Power vitesse Speed to charge load (%) (%) puissance factor 4/4 79 80,5 79 80,5 80,5 79 80,5 82 84 82 84 84 3/4 78 80,5 78 80,5 80,5 78 80,5 82 84 82 84 84 2/4 76 78,0 76 78,0 78,0 76 78,0 80 82 80 82 82 cos φ 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,77 0,89 0,77 0,89 0,89 Tr/min rpm 2850 2850 2850 2850 2850 2850 2850 2900 2900 2900 2900 2900 tension motor voltage moteur 3x230 V 3x400 V 3,2 4,3 3,2 4,3 4,3 3,2 4,3 5,7 8,8 5,7 8,8 8,8 1,85 2,5 1,85 2,5 2,5 1,85 2,5 3,3 5,1 3,3 5,1 5,1 Orifices Suction Orifices Ports ports. asp. ref. DNA DNR 1 1 1¼ 1¼ 1¼ 1½ 1½ 1½ 1½ 2 2 2 1 1 1 1 1 1¼ 1¼ 1¼ 1¼ 1½ 1½ 1½ H POMPE PUMP H1 H2 L mm mm mm mm 219 219 219 219 219 219 219 240 240 240 240 240 90 90 90 90 90 90 90 90 90 90 90 90 104 104 104 104 104 104 104 104 104 105 105 105 L1 L2 mm 457 252 481 276 457 252 457 252 481 276 421 216 421 216 523 276 523 276 482 236 482 235,5 526 280,5 L3 L4 mm mm mm mm 110 110 110 110 110 110 110 148 148 148 148 148 157,5 181,5 157,5 157,5 181,5 121,5 121,5 181,5 181,5 138 138 183 52 52 52 52 52 52 52 52 52 55 55 55 L5 52 52 52 52 52 52 52 52 52 52 52 52 masse mass ORDER REFERENCE COMMANDE REFERENCE 190 kg 13 13,8 13 13,8 16 12,3 13,1 19,1 20,5 19 21,4 22,1 7 MULTI-H RECOMMENDED ACCESSORIES • ACSON : ON/OFF control device and protection against lack of water. • Shut-off valve • Strainer foot valve • Protective slave switch for three-phase motor • Non-return valve FEATURES a) Electrical - IE2 “T” types: 230-400 V - 50 Hz three-phase - “M” types: - 230 V - 50 Hz single-phase with capacitor integrated into the terminal box. - Three-phase motors MUST be protected by a slave switch. - Stuffing box used for connections to the motor terminal box Provide a switch and low-water protection box in both single-phase and three-phase. b) Fitting - On solid base using foundation bolts. - Installation of pump in suction mode with compulsory strainer foot valve, or flooded suction mode on storage tank or mains water system with low water protection kit. - Connection to pump via a flexible hose or rigid piping. - The installation must allow for the protection of the pump against adverse weather conditions and frost (avoid direct exposure to rain or sun). c) Packaging Pump delivered in cardboard packaging, without connection fittings. d) Maintenance Replacement of recommended spare parts (•) subject to wear. • Water hammer tank • Vibration-damping sleeves • Bladder tank OPTIONS AND ACCESSORIES • Shut-off valves • Non-return valves • Strainer foot valve • Vibration-damping sleeves • Suction kit • Bladder or galvanised tanks • Water hammer tanks • ME low-water protection kit • ACSON: ON/OFF control device and protection against lack of water • Protective slave switch for three-phase motor… 8 OPERATING RANGES 55 m Manometric heads of up to: 4 bar Max. operating pressure: +50°C Max. temperature: 7m Max. suction head: 1” - 1”1/4 DN suction: 1” DN delivery: APPLICATIONS 65 Pressure maintenance for water distribution systems with insufficient or non-existent pressure in the domestic and small-scale collective sectors: • Water supply and distribution from wells, springs or storage tanks. • Irrigation - watering. 55 ELINOX-H ALTi-H Hm HYDROMINI MULTi-H 0 HYDROMINI MULTI-H 8 m3/h Flow rates of up to: Qm3/h 2 pompes ALTISON 8 • Raising the pressure of a weak mains water system (if the total pressure does not exceed 4 bar). For detached houses, rural homes, small farms, small-scale industries... 30 Certified • HYDROMINI MULTi-H ADVANTAGES • Surpresseurs entièrement montés, câblés et préréglés, prêts à l’emploi. • Easy installation: one electrical connection and two hydraulic connections. • Stainless steel hydraulic assembly. • Interchangeable butyl, food-grade bladder tank. • Integrated thermal protection of motor on all models. • User-friendly operation and maintenance at low cost DESIGN Automatic booster pumps, pre-assembled and ready for fitting, equipped with: - MULTi-H single-phase or three-phase pump (203; 204; 205; 404; 405) - Tank with an interchangeable bladder (24, 50 and 100 l) - Filler plug - Drain plug - Cable and plug (single-phase version) - Pump/tank connection hose - Inflation valve - Pressure gauge and pressure switch. HYDROMINI SINGLE-PHASE - Thermal protection integrated into the winding, automatic resetting after cooling. HYDROMINI THREE-PHASE - Thermal protection of motor integrated into the pressure switch; manual resetting. The installation must allow for the protection of the pump against adverse weather conditions and frost (avoid direct exposure to rain or sun). The setting of on-off pressures on the contact or pressure switch is carried out in the factory. Standards: EN 60335-2-41 9 HYDROMINI MULTI-H MULTI-H HYDRAULIC, ELECTRICAL AND DIMENSIONAL SPECIFICATIONS Imp.gpm 5 10 15 205 204 40 MULTi-H 200 50Hz 203 30 Hft 150 100 20 50 10 1 Qm3/h Ql/min 20 Ql/s 0,2 0,4 2 3 40 0,6 4 0,8 60 1 5 80 0 1,2 DNR H 0 Imp.gpm 5 10 10 15 15 0 20 2520 Imp.gpm 30 Hm Hm Hft 405 MULTi-H 400 Hft MULTi-H200 50 205 150 80 50Hz 60Hz 404 40 70 204 100 30 20 60 50 203 20 50 40 10 10 30 0 0 20 2 3 4 5 6 7 8 9 Qm3/h 10 40 60 80 100 120 140 Ql/min 0 0 Ql/s 13 0 1 0,5 2 41,5 5 2 6 Qm32,5 /h DNA Hm 50 Tension Voltage Volume 50Hz L H L P H1 L1 L2 P1 X X1 mm mm mm mm mm mm mm mm mm Multi-H-203-M-H20 1” 1” 1~230 V 20 570 500 280 385 220 170 230 110 375 Multi-H-203-M-H50 1” 1” 1~230 V 50 655 700 360 470 350 300 280 110 375 Multi-H-203-M-H100 1” 1” 1~230 V 100 750 820 450 565 400 350 320 110 375 Multi-H-203-T-H20 1” 1” 3~230/400 V 20 570 500 280 385 220 170 230 110 375 Multi-H-203-T-H50 1” 1” 3~230/400 V 50 655 700 360 470 350 300 280 110 375 Multi-H-203-T-H100 1” 1” 3~230/400 V 100 750 820 450 565 400 350 320 110 375 Multi-H-204-M-H20 1” 1” 1~230 V 20 570 500 280 385 220 170 230 158 423 Multi-H-204-M-H50 1” 1” 1~230 V 50 655 700 360 470 350 300 280 158 423 Multi-H-204-M-H100 1” 1” 1~230 V 100 750 820 450 565 400 350 320 158 423 Multi-H-204-T-H20 1” 1” 3~230/400 V 20 570 500 280 385 220 170 230 158 423 Multi-H-204-T-H50 1” 1” 3~230/400 V 50 655 700 360 470 350 300 280 158 423 Multi-H-204-T-H100 1” 1” 3~230/400 V 100 750 820 450 565 400 350 320 158 423 1” 1” 1~230 V 20 570 500 280 385 220 170 230 158 423 Multi-H-205-M-H50 1” 1” 1~230 V 50 655 700 360 470 350 300 280 158 423 Multi-H-205-M-H100 1” 1” 1~230 V 100 750 820 450 565 400 350 320 158 423 1” 1” 3~230/400 V 20 597 500 280 385 220 170 230 158 457 1” 1” 3~230/400 V 50 682 700 360 470 350 300 280 158 457 1” 1” 3~230/400 V 100 777 820 450 565 400 350 320 158 457 1”1/4 1” 1~230 V 20 570 500 280 385 220 170 230 158 423 1”1/4 1” 1~230 V 50 655 700 360 470 350 300 280 158 423 1”1/4 1” 1~230 V 100 750 820 450 565 400 350 320 158 423 Multi-H-404N-T-H20 1”1/4 1” 3~230/400 V 20 597 500 280 385 220 170 230 158 457 Multi-H-404N-T-H50 1”1/4 1” 3~230/400 V 50 682 700 360 470 350 300 280 158 457 Multi-H-404N-T-H100 1”1/4 1” 3~230/400 V 100 777 820 450 565 400 350 320 158 457 Multi-H-405-M-H20 1”1/4 1” 1~230 V 20 570 500 280 385 220 170 230 158 448 Multi-H-405-M-H50 1”1/4 1” 1~230 V 50 655 700 360 470 350 300 280 158 448 Multi-H-405-M-H100 1”1/4 1” 1~230 V 100 Multi-H-405N-T-H20 1”1/4 1” 3~230/400 V 20 750 820 450P1565 400 350 320 158 448 Multi-H-405N-T-H50 1”1/4 1” 3~230/400 V 50 682 700 360 470 350 300 280 158 457 Multi-H-405N-T-H100 1”1/4 1” 3~230/400 V 100 777 820 450 565 400 350 320 158 457 Mean flow rate: Capacity: 2 000 to 8 000 l/h Pressure on: Pressure off: DN (nominal diameter) suction: DN delivery: 10 20 to 100 l 1,5 to 2 bar 3 to 3,5 bar 1” - 1”1/4 1” X1 X H1 Multi-H-404-M-H50 Multi-H-404-M-H100 TANKS P H Multi-H-205N-T-H20 Multi-H-205N-T-H50 Multi-H-205N-T-H100 P1 DNR Multi-H-205-M-H20 Multi-H-404-M-H20 H1 DNA DNR DNA Produit Product L2 597 500 280 385 220 170 230 158 457 P • Low-water protection kit for connecting HYDROMINI to the mains system. L1 L RECOMMENDED ACCESSORIES • Strainer foot valve (max. flow section 1 mm). • 1/4 T valve on suction. • 1/4 T valve on delivery. • Non-return valve • Pipe hanger. • Low-water protection kit (connection to mains system). • Float switch, pressure switch or PMS
Similar documents
ASP Axially Split Case Pumps
Wear rings Bronze G-CuPb10 Sn B584 C93 700 Shaft Stainless Steel X12cr13 A276 Type 410 Designaton Material Temperature Mechanical seal Carbon / Silicon-Carbide / EPDM -8 to 120°C (others on request)
More information