Axor ShowerCollection with Philippe Starck

Transcription

Axor ShowerCollection with Philippe Starck
Axor ShowerCollection with Philippe Starck
0
55870 39473
5
CA—Axor ShowerCollection Professional Brochure . Part No. MKT-12-137E . Printed October 2012
Subject to technical alterations and color discrepancies
Information and Inspiration for Professionals
To obtain more information on Axor products, call toll-free:
800-334-0455
www.hansgrohe.ca
CONTENTS
04
10
36
48
54
The Modular Principle
The Planning Examples
The Installations
Product Overview
Project References
PHILIPPE STARCK
Philippe Starck is one of the best known creative minds of our time.
Many people regard him as having a streak of genius, which regularly
provokes with its playful, often spectacular style.
· Interior and general designer
· Born in Paris, France, in 1949
· Founded the company ”Starck Product“ in 1979
· His partners include Kartell, Alessi, Duravit, Driade, Fossil and Cassina
· Projects: yoo Apartments, motor yacht A, Café Costes in Paris,
Hotel St. Martins Lane in London
· Collaboration with Axor since 1992
01
Axor ShowerCollection
5X
"
Haute Couture for the Shower
How much potential is in a square? Axor ShowerCollection shows there is a vast amount.
Showers, mixing valves and accessories that can be freely combined to create custom
solutions, which can be perfectly tailored to the requirements of your customer.
Each element of the collection was developed by Axor and Philippe Starck, based on a
5 x 5-inch square. On the following pages, you can see for yourself how perfectly all the
components work together.
We will explain how the modular principle informs not only the beautiful aesthetic of the
finished trims, but also the rough components behind the wall, making them very easy to
assemble. Six comprehensive planning examples provide you with detailed information
on the actual installation.
This brochure for professionals shows you how easy it is to turn an ordinary shower into
a personal spa with Axor ShowerCollection.
Axor ShowerCollection
Axor ShowerCollection
with Philippe Starck
02
03
Axor ShowerCollection
the Modular Principle
The Concept
A simple, modular system whose components can be freely arranged in almost
any configuration — that is the essence of Axor ShowerCollection. “Just mix it!” is
the motto for individuality and creativity in shower planning. From the Thermostatic
Module to the 10 x 10-inch Showerhead, from the Shelf to the ShowerHeaven,
your customer simply selects which components he would like to use.
Axor ShowerCollection is also impressive behind the wall, with solutions that are
both innovative and easy-to-install. So, the collection combines ultimate freedom
of design with reliable installation.
The "Just mix it!" principle has proven successful with a wide range of installation
scenarios, from the standard to the luxurious.
Axor ShowerCollection
04
05
Axor ShowerCollection
the Modular Principle
Squaring the Circle
The Collection
Few shower systems are as versatile as Axor ShowerCollection.
Philippe Starck continues his minimalist approach with this
collection, and all components are based on the 5 x 5 principle.
01
02
03
04
05
06
07
08
09
10
11
12
13
The benefits of Axor ShowerCollection:
· A versatile style which is a perfect fit for any Axor collection
and any design language
· A wealth of design options, thanks to the “Just mix it!” philosophy
01
02
03
Thermostatic Module (15 x 5 inches)
Thermostatic Mixer (5 x 5 inches)
Volume Control (5 x 5 inches)
Trio/Quattro Diverter (5 x 5 inches)
Handshower Module (5 x 5 inches)
Tub Spout (10 x 5 inches)
Shower Module (5 x 5 inches)
Showerhead (10 x 10 inches)
ShowerHeaven (28 x 28 inches)
Light Module (5 x 5 inches)
Speaker Module (5 x 5 inches)
Short Shelf (5 x 5 inches)
Long Shelf (10 x 5 inches)
04
05
Valve Trims
The valve trims captivate with their precision. The foundation is
the Thermostatic Module, with three integrated volume controls.
Additional trims are available for individual add-on functions.
The Handshower Module is especially elegant, with an integrated
volume control.
06
Tub Spout
An exciting addition to Axor ShowerCollection, this new
multifunctional tub spout serves as a 10-inch shelf and as
a spout with waterfall spray in one.
Axor ShowerCollection
09
08
07
06
07
Showers
Accessories
The 5 x 5-inch Shower Module presents water in a sleek
geometric design — whether in the form of an overhead,
shoulder or body shower. The new 10 x 10-inch showerhead
is a perfect blend of performance and installation versatility.
And with its size and elegant geometry, the ShowerHeaven
becomes a luxurious architectural design element.
Axor ShowerCollection excels down to the last detail. Two different
shelf sizes help to store and organize your shower accessories.
The speakers allow you to enjoy your favorite music, for a new
showering experience. Atmospheric lighting eases the stress of a
hectic lifestyle and exudes a sensual, harmonious ambiance.
10
11
12
13
Axor ShowerCollection
the Modular Principle
The ShowerHeaven
With three distinctive spray zones, the
ShowerHeaven guarantees a truly special
showering experience.
The Spray Zones (from left to right):
· Bodyzone is the 20 x 20-inch outermost showerhead zone
· Rainzone is the air-injected 10 x 10-inch central showerhead zone
· Laminar spray is a powerful 3 ⁄4"
diameter, non-aerated stream in the
very center
· A combination of spray zones (always comply with your local plumbing codes)
The Shower Module as
a Showerhead
Multiple Shower Modules can be
configured into an overhead shower
by mounting them adjacently or in
a custom pattern.
Axor ShowerCollection
The Showerheads
· 10 x 10-inch size is perfect for
any shower installation
· Two versions are available:
Ceiling-mounted (requires 10"
Ceiling Showerarm), or wall-mounted
with an integrated showerarm.
· Easy cleaning: The sprayface can
be detached for cleaning
The Tub Spout
· Luxurious waterfall spray
· Integrated shelf for storing
bath accessories
08
09
The Shower Module as
a Body Shower
· With three different vertical settings,
the water jets can be easily directed
towards specific parts of your body
(e.g. neck, shoulders, body or thighs)
and adjusted for different body sizes
· If rotated by 90° when installed,
the spray settings can be adjusted horizontally instead of vertically.
So the jets can either cover a larger area, or converge at a certain point.
Axor ShowerCollection
the PLANNING EXAMPLES
ShowerHeaven
The Shower for Minimalists
This planning example embodies the dream shower
of the designer Philippe Starck. All elements are
conventionally arranged vertically, and ergonomically.
· Light and Speaker Modules are installed at
eye and ear level
· Short Shelf: Practical for storing personal items
· Shower Modules in the neck and lumbar region
can be vertically adjusted for different body sizes
· The Thermostatic Module controls your ideal
temperature and the 3 ShowerHeaven spray zones
· Handshower Module for easy access
·The Volume Control adjusts the Shower Modules
Light Module
Speaker Module
Short Shelf
Shower Module
Volume Control
Thermostatic Module
Shower Module
Handshower Module
Axor ShowerCollection
the PLANNING EXAMPLES
1
ShowerHeaven
PLANNING
EXAMPLE
Axor ShowerCollection
Axor ShowerCollection
Handshower
Module
Long Shelf
Volume
Control
Thermostatic
Module
10
11
This horizontal configuration combines
all functional and shelving modules at an
ergonomic height. So all functions can
be used comfortably, and your personal
accessories are at your fingertips.
· 4 Shower Modules can be used as a
neck shower, with 3 vertical adjustment positions to accommodate any body size
· Thermostatic Module is installed on the left with 3 integrated volume controls
for adjusting the ShowerHeaven
· Separate Volume Control for the
Shower Modules
· 10" Long Shelf offers convenient space
for personal items
Shower Module
The Deluxe Versions
the PLANNING EXAMPLES
1
ShowerHeaven
PLANNING
EXAMPLE
Axor ShowerCollection
Axor ShowerCollection
Handshower
Module
Long Shelf
Volume
Control
Thermostatic
Module
10
11
This horizontal configuration combines
all functional and shelving modules at an
ergonomic height. So all functions can
be used comfortably, and your personal
accessories are at your fingertips.
· 4 Shower Modules can be used as a
neck shower, with 3 vertical adjustment positions to accommodate any body size
· Thermostatic Module is installed on the left with 3 integrated volume controls
for adjusting the ShowerHeaven
· Separate Volume Control for the
Shower Modules
· 10" Long Shelf offers convenient space
for personal items
Shower Module
The Deluxe Versions
Hot Water
Cold Water
1
Mixed Water
Dimensions assume a
body height of 5'-11"
Components
Ceiling Construction
1 x ShowerHeaven
(concealed installation)
#10625801
1
Lowered Ceiling
The three supply lines for the ShowerHeaven must be routed through
the ceiling. To install the Shower­Heaven #10625801 flush with the
ceiling, you need an intermediate or lowered ceiling, made e. g. of
gypsum board with a clearance of at least 3". The net weight of the
ShowerHeaven without water is approximately 65 lbs.
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
Plumbing installation
8
Short Shelf
#40872000
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
2 x Shower Module Trim
#28491001
2 x Rough, Shower Module
#28486181
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
11
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
10
8
9
1 x Short Shelf
#40872000
5
6
3
4
5
1 x Mounting Plate
#10973180
7
44"
2
1 x Speaker Module
#40874001
1 x Light Module
#40871001
2 x Light/Speaker Modules Basic Set
#40876180
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly.
3
Supply Lines
Thermostatic Module with Volume Controls: 2 x 3 ⁄4" (hot/cold)
ShowerHeaven: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the ShowerHeaven. A rough
is required (#10750181) to install the Thermostatic Module
with Volume Controls. Both parts must be ordered separately.
Maximum throughput of module is 15 GPM at 44 PSI.
4
9
Mounting Plate
#10973180
For the optimized positioning (distance 1 ⁄ 2") of the Light Module,
Speaker Module and the Shelf, the Mounting Plate #10973180
is recommended.
Speaker Module
#40874001
Basic Set #40876180 is required.
Both parts must be ordered separately.
10
Light Module
#40871001
Basic Set #40876180 is required.
Both parts must be ordered separately.
11
Draining technique
12 Drain
The throughput of the drain must be at least 13 GPM.
5
Shower Module
#28491001
To maintain proper 1 ⁄ 2" spacing and alignment of the Shower
Modules adjacent to the other modules, rough #28486181
is required. Both parts must be ordered separately. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
6
Volume Control
#10972001
Required for controlling the two Shower Modules. To install
inline with other modules (1 ⁄ 2" spacing between modules)
use rough #10971181. Both parts must be ordered separately.
Maximum throughput of module is 14 GPM at 44 PSI.
You will find a detailed description of the individual installation steps starting
on page 38.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
12
Axor ShowerCollection
Hot Water
Cold Water
1
Mixed Water
Dimensions assume a
body height of 5'-11"
Components
Ceiling Construction
1 x ShowerHeaven
(concealed installation)
#10625801
1
Lowered Ceiling
The three supply lines for the ShowerHeaven must be routed through
the ceiling. To install the Shower­Heaven #10625801 flush with the
ceiling, you need an intermediate or lowered ceiling, made e. g. of
gypsum board with a clearance of at least 3". The net weight of the
ShowerHeaven without water is approximately 65 lbs.
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
Plumbing installation
8
Short Shelf
#40872000
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
2 x Shower Module Trim
#28491001
2 x Rough, Shower Module
#28486181
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
11
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
10
8
9
1 x Short Shelf
#40872000
5
6
3
4
5
1 x Mounting Plate
#10973180
7
44"
2
1 x Speaker Module
#40874001
1 x Light Module
#40871001
2 x Light/Speaker Modules Basic Set
#40876180
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly.
3
Supply Lines
Thermostatic Module with Volume Controls: 2 x 3 ⁄4" (hot/cold)
ShowerHeaven: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the ShowerHeaven. A rough
is required (#10750181) to install the Thermostatic Module
with Volume Controls. Both parts must be ordered separately.
Maximum throughput of module is 15 GPM at 44 PSI.
4
9
Mounting Plate
#10973180
For the optimized positioning (distance 1 ⁄ 2") of the Light Module,
Speaker Module and the Shelf, the Mounting Plate #10973180
is recommended.
Speaker Module
#40874001
Basic Set #40876180 is required.
Both parts must be ordered separately.
10
Light Module
#40871001
Basic Set #40876180 is required.
Both parts must be ordered separately.
11
Draining technique
12 Drain
The throughput of the drain must be at least 13 GPM.
5
Shower Module
#28491001
To maintain proper 1 ⁄ 2" spacing and alignment of the Shower
Modules adjacent to the other modules, rough #28486181
is required. Both parts must be ordered separately. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
6
Volume Control
#10972001
Required for controlling the two Shower Modules. To install
inline with other modules (1 ⁄ 2" spacing between modules)
use rough #10971181. Both parts must be ordered separately.
Maximum throughput of module is 14 GPM at 44 PSI.
You will find a detailed description of the individual installation steps starting
on page 38.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
12
Axor ShowerCollection
PLANNING
EXAMPLE
2
Shower
Module
the PLANNING EXAMPLES
The Complete Shower Experience
Installed in a corner, this solution offers the complete water
experience. Water from three sides: 6 overhead Shower Modules
and 6 body Shower Modules, 3 on each side.
· The 6 overhead Shower Modules are centrally controlled by one of the Volume Controls, integrated in the Thermostatic Module
· Additional Shower Modules are installed in a corner setup
allowing for an exhilarating experience, the Shower Modules
on each side are controlled independently.
· The Handshower adds the increased versatility, not only allowing you to easily direct water towards specific areas of your body, but makes cleaning your shower area easier.
Axor ShowerCollection
Axor ShowerCollection
Handshower
Module
Short Shelf
Shower
Module
Shower
Module
Thermostatic
Module
14
15
PLANNING
EXAMPLE
2
Shower
Module
the PLANNING EXAMPLES
The Complete Shower Experience
Installed in a corner, this solution offers the complete water
experience. Water from three sides: 6 overhead Shower Modules
and 6 body Shower Modules, 3 on each side.
· The 6 overhead Shower Modules are centrally controlled by one of the Volume Controls, integrated in the Thermostatic Module
· Additional Shower Modules are installed in a corner setup
allowing for an exhilarating experience, the Shower Modules
on each side are controlled independently.
· The Handshower adds the increased versatility, not only allowing you to easily direct water towards specific areas of your body, but makes cleaning your shower area easier.
Axor ShowerCollection
Axor ShowerCollection
Handshower
Module
Short Shelf
Shower
Module
Shower
Module
Thermostatic
Module
14
15
3"
Hot Water
Cold Water
3"
Components
CEILING CONSTRUCTION
1 x ShowerHeaven
(exposed installation)
#10625801
Ceiling
The three supply lines for the ShowerHeaven must be routed
through the ceiling. The net weight of the ShowerHeaven
without water is approximately 65 lbs. The lowered ceiling must
be strong enough to carry the weight of the ShowerHeaven.
6
Volume Control
#10972001
Required for controlling the Shower Modules. To install inline
with other modules (1 ⁄ 2" spacing between modules) use
rough #10971181. Both parts must be ordered separately.
Maximum throughput of module is 14 GPM at 44 PSI.
PLUMBING installation
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
1
Mixed Water
Dimensions assume a
body height of 5'-11"
7"
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
4 x Shower Module Trim
#28491001
4 x Rough, Shower Module #28486181
3
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
5
1 x Long Shelf
#40873000
1 x Long Shelf Basic Set
#40878180
2
8
7
58"
6
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
3
Supply Lines
Thermostatic Module with Volume Controls: 2 x 3 ⁄4" (hot/cold)
ShowerHeaven: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the ShowerHeaven. A rough
is required (#10750181) to install the Thermostatic Module
with Volume Controls. Both parts must be ordered separately.
Maximum throughput of module is 15 GPM at 44 PSI.
4
5
Shower Module
#28491001
To maintain proper 1 ⁄ 2" spacing and alignment of the Shower
Modules adjacent to the other modules, rough #28486181
is required. Both parts must be ordered separately. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
8
Long Shelf
#40873000
Since the Long Shelf is installed between two water-bearing parts,
Basic Set #40878180 is needed as a water throughput
between the Volume Control and the Handshower Module.
Draining technique
9
Drain
The throughput of the drain must be at least 13 GPM.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
40"
4
1
9
Axor ShowerCollection
3"
Hot Water
Cold Water
3"
Components
CEILING CONSTRUCTION
1 x ShowerHeaven
(exposed installation)
#10625801
Ceiling
The three supply lines for the ShowerHeaven must be routed
through the ceiling. The net weight of the ShowerHeaven
without water is approximately 65 lbs. The lowered ceiling must
be strong enough to carry the weight of the ShowerHeaven.
6
Volume Control
#10972001
Required for controlling the Shower Modules. To install inline
with other modules (1 ⁄ 2" spacing between modules) use
rough #10971181. Both parts must be ordered separately.
Maximum throughput of module is 14 GPM at 44 PSI.
PLUMBING installation
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
1
Mixed Water
Dimensions assume a
body height of 5'-11"
7"
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
4 x Shower Module Trim
#28491001
4 x Rough, Shower Module #28486181
3
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
5
1 x Long Shelf
#40873000
1 x Long Shelf Basic Set
#40878180
2
8
7
58"
6
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
3
Supply Lines
Thermostatic Module with Volume Controls: 2 x 3 ⁄4" (hot/cold)
ShowerHeaven: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the ShowerHeaven. A rough
is required (#10750181) to install the Thermostatic Module
with Volume Controls. Both parts must be ordered separately.
Maximum throughput of module is 15 GPM at 44 PSI.
4
5
Shower Module
#28491001
To maintain proper 1 ⁄ 2" spacing and alignment of the Shower
Modules adjacent to the other modules, rough #28486181
is required. Both parts must be ordered separately. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
8
Long Shelf
#40873000
Since the Long Shelf is installed between two water-bearing parts,
Basic Set #40878180 is needed as a water throughput
between the Volume Control and the Handshower Module.
Draining technique
9
Drain
The throughput of the drain must be at least 13 GPM.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
40"
4
1
9
Axor ShowerCollection
the PLANNING EXAMPLES
PLANNING
EXAMPLE
3
Showerhead
The Complete Shower Experience
18
19
With its compact 10 x 10-inch Wall-Mounted
Showerhead, Axor ShowerCollection offers a
convenient solution for smaller bathrooms, too.
· Separate temperature control with a
Thermostatic Mixer
· Volume Control above the Thermostatic Mixer controls the Showerhead
· Handshower Module below the Thermostatic Mixer features an integrated Volume Control
· 2 Short Shelves provide space for personal items
Volume Control
Thermostatic Mixer
2 Short Shelves
Handshower Module
Axor ShowerCollection
Axor ShowerCollection
the PLANNING EXAMPLES
PLANNING
EXAMPLE
3
Showerhead
The Complete Shower Experience
18
19
With its compact 10 x 10-inch Wall-Mounted
Showerhead, Axor ShowerCollection offers a
convenient solution for smaller bathrooms, too.
· Separate temperature control with a
Thermostatic Mixer
· Volume Control above the Thermostatic Mixer controls the Showerhead
· Handshower Module below the Thermostatic Mixer features an integrated Volume Control
· 2 Short Shelves provide space for personal items
Volume Control
Thermostatic Mixer
2 Short Shelves
Handshower Module
Axor ShowerCollection
Axor ShowerCollection
Hot Water
Components
CEILING CONSTRUCTION
12 x Shower Module Trim
#28491001
2 x Rough, Shower Module
#28486181
1 x Shower Modules Mounting Plate
#28470181
Lowered Ceiling
To install the Shower Modules, the connecting lines must be
routed through the ceiling. For the proper installation of the 6
Shower Modules in the ceiling (#28491001), we recommend
using the Mounting Plate #28470181.
6
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
PLUMBING installation
7
Short Shelf
#40872000
Since the Short Shelf is installed between two water-bearing parts,
Basic Set #40877180 is needed as a water throughput
between the Shower Module and the Handshower Module.
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1
1 x Short Shelf
#40872000
1 x Short Shelf Basic Set
#40877180
3
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
1
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
Draining technique
8
Drain
The throughput of the drain must be at least 13 GPM.
3
Supply Lines
Hot and Cold Supply: 2 x 3 ⁄4"
Shower Modules in the wall: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the Shower Modules installed
in the ceiling and the wall. A rough is required (#10750181) to
install the Thermostatic Module with Volume Controls. Both parts
must be ordered separately. Maximum throughput of module is
15 GPM at 44 PSI.
4
5
5
7
6
5
2
5
55"
4
5
24"
40"
5
5
Shower Module (Wall installation)
#28491001
The three Shower Modules on the left can be operated separately
from the three Shower Modules on the right. The control takes place
via the Thermostatic Module. To maintain proper 1 ⁄ 2" spacing and
alignment of the Shower Modules adjacent to the other modules
and the Thermostatic Module, rough #28486181 is required, and
must be ordered separately. The upper and lower Shower Modules
can be installed using a standard 1 ⁄ 2" wall connection. Maximum
flow rate (with 6 Shower Modules) is 6 GPM at 44 PSI.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
8
Axor ShowerCollection
Hot Water
Components
CEILING CONSTRUCTION
12 x Shower Module Trim
#28491001
2 x Rough, Shower Module
#28486181
1 x Shower Modules Mounting Plate
#28470181
Lowered Ceiling
To install the Shower Modules, the connecting lines must be
routed through the ceiling. For the proper installation of the 6
Shower Modules in the ceiling (#28491001), we recommend
using the Mounting Plate #28470181.
6
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
1 x Thermostatic Module Trim
with Volume Controls
#10751001
1 x Rough, Thermostatic Module
with Volume Controls
#10750181
PLUMBING installation
7
Short Shelf
#40872000
Since the Short Shelf is installed between two water-bearing parts,
Basic Set #40877180 is needed as a water throughput
between the Shower Module and the Handshower Module.
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1
1 x Short Shelf
#40872000
1 x Short Shelf Basic Set
#40877180
3
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
1
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
Draining technique
8
Drain
The throughput of the drain must be at least 13 GPM.
3
Supply Lines
Hot and Cold Supply: 2 x 3 ⁄4"
Shower Modules in the wall: 3 x 3 ⁄4" (mixed water)
Thermostatic Module with Volume Controls
#10751001
Thermostatic Module with Volume Controls with increased flow
performance is ideal for controlling the Shower Modules installed
in the ceiling and the wall. A rough is required (#10750181) to
install the Thermostatic Module with Volume Controls. Both parts
must be ordered separately. Maximum throughput of module is
15 GPM at 44 PSI.
4
5
5
7
6
5
2
5
55"
4
5
24"
40"
5
5
Shower Module (Wall installation)
#28491001
The three Shower Modules on the left can be operated separately
from the three Shower Modules on the right. The control takes place
via the Thermostatic Module. To maintain proper 1 ⁄ 2" spacing and
alignment of the Shower Modules adjacent to the other modules
and the Thermostatic Module, rough #28486181 is required, and
must be ordered separately. The upper and lower Shower Modules
can be installed using a standard 1 ⁄ 2" wall connection. Maximum
flow rate (with 6 Shower Modules) is 6 GPM at 44 PSI.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
8
Axor ShowerCollection
the PLANNING EXAMPLES
4
Showerhead
PLANNING
EXAMPLE
Axor ShowerCollection
Axor ShowerCollection
Volume Control
2 Shower Modules
Short Shelf
Short Shelf
Volume Control
Thermostatic Mixer
22
23
This walk-in shower has an open,
visually-balanced design — yet
offers the convenience of an
enclosure made possible by a
large sliding glass door.
· The new 10" Showerhead with Ceiling Showerarm offers the perfect balance of performance and installation versatility.
· Shelves provide space for
personal items on both sides
Handshower Module
The Walk-in Shower
the PLANNING EXAMPLES
4
Showerhead
PLANNING
EXAMPLE
Axor ShowerCollection
Axor ShowerCollection
Volume Control
2 Shower Modules
Short Shelf
Short Shelf
Volume Control
Thermostatic Mixer
22
23
This walk-in shower has an open,
visually-balanced design — yet
offers the convenience of an
enclosure made possible by a
large sliding glass door.
· The new 10" Showerhead with Ceiling Showerarm offers the perfect balance of performance and installation versatility.
· Shelves provide space for
personal items on both sides
Handshower Module
The Walk-in Shower
Hot Water
Components
CEILING CONSTRUCTION
1 x Wall-Mounted Showerhead
Trim with Showerarm
#10925001
1 x Rough, Wall-Mounted Showerhead
#10921181
Wall
Rough #10921181 is used to install the Wall-Mounted
Showerhead with Showerarm #10925001.
This ensures that the Shower­head is both mounted securely
and perfectly aligned to the wall. Rough #10921181 must be
ordered separately. The net weight of the Showerhead with
Showerarm without water is approximately 15 lbs.
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1 x Thermostatic Mixer Trim
#10755001
1 x Rough, Thermostatic Mixer
#10754181
1
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
3
1
PLUMBING installation
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
5
Volume Control
#10972001
Required for controlling the Showerhead. To install inline with other
modules (1⁄2" spacing between modules) use rough #10971181.
Both parts must be ordered separately. Maximum throughput of
module is 14 GPM at 44 PSI.
6
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
7
Short Shelf
#40872000
This installation uses two shelves, resulting in both visual symmetry
and functionality.
Draining technique
2 x Short Shelf
#40872000
Supply Lines
Thermostatic Mixer: 2 x 3 ⁄4" (hot/cold)
Wall-Mounted Showerhead with Showerarm: 1 x 3 ⁄4" (mixed water)
3
Thermostatic Mixer
#10755001
A rough is required (#10754181) to install the Thermostatic Mixer.
Both parts must be ordered separately. Maximum throughput of
module is 15 GPM at 44 PSI.
Drain
The throughput of the drain must be at least 5 GPM.
85"
4
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
5
7
7
6
47"
2
4
Axor ShowerCollection
Hot Water
Components
CEILING CONSTRUCTION
1 x Wall-Mounted Showerhead
Trim with Showerarm
#10925001
1 x Rough, Wall-Mounted Showerhead
#10921181
Wall
Rough #10921181 is used to install the Wall-Mounted
Showerhead with Showerarm #10925001.
This ensures that the Shower­head is both mounted securely
and perfectly aligned to the wall. Rough #10921181 must be
ordered separately. The net weight of the Showerhead with
Showerarm without water is approximately 15 lbs.
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1 x Thermostatic Mixer Trim
#10755001
1 x Rough, Thermostatic Mixer
#10754181
1
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
3
1
PLUMBING installation
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
5
Volume Control
#10972001
Required for controlling the Showerhead. To install inline with other
modules (1⁄2" spacing between modules) use rough #10971181.
Both parts must be ordered separately. Maximum throughput of
module is 14 GPM at 44 PSI.
6
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
7
Short Shelf
#40872000
This installation uses two shelves, resulting in both visual symmetry
and functionality.
Draining technique
2 x Short Shelf
#40872000
Supply Lines
Thermostatic Mixer: 2 x 3 ⁄4" (hot/cold)
Wall-Mounted Showerhead with Showerarm: 1 x 3 ⁄4" (mixed water)
3
Thermostatic Mixer
#10755001
A rough is required (#10754181) to install the Thermostatic Mixer.
Both parts must be ordered separately. Maximum throughput of
module is 15 GPM at 44 PSI.
Drain
The throughput of the drain must be at least 5 GPM.
85"
4
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
5
7
7
6
47"
2
4
Axor ShowerCollection
PLANNING
EXAMPLE
5
26
27
Axor ShowerCollection
Axor ShowerCollection
PLANNING
EXAMPLE
5
26
27
Axor ShowerCollection
Axor ShowerCollection
Hot Water
Components
CEILING CONSTRUCTION
1 x Showerhead
#10926001
1 x Ceiling Showerarm, 10"
#26414001
1 x Thermostatic Mixer Trim
#10755001
1 x Rough, Thermostatic Mixer
#10754181
Ceiling Connector
To install Showerhead #10926001, the 10" Ceiling Showerarm
(sold separately) must be screwed into a 1⁄ 2" internal thread.
The Showerarm is then attached to the connection fitting and
fixed with screws. Lastly, the Showerhead is screwed tightly onto
the ceiling connector.
Attention: The net weight of the Showerhead is approximately
4.5 lbs. without water. Please provide an adequate ceiling
reinforcement at this point.
2 x Shower Module Trim
#28491001
PLUMBING installation
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1
2
5
8
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
2 x Short Shelf
#40872000
2x Short Shelf Basic Set
#40877180
3
Supply Lines
Thermostatic Mixer: 2 x 3 ⁄4" (hot/cold)
Showerhead: 1 x 3 ⁄4" (hot/cold)
Volume Control for Shower Modules: 1 x 3 ⁄4" (mixed water)
2 x Volume Control Trim
#10972001
2 x Rough, Volume Control
#10971181
3
3
1
6
Volume Control
#10972001
Required for controlling the Showerhead. To install inline with other
modules (1⁄ 2" spacing between modules) use rough #10971181.
Both parts must be ordered separately. Maximum throughput of
module is 14 GPM at 44 PSI.
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
8
Short Shelf
#40872000
Since the Short Shelf is installed between two water-bearing parts,
Basic Set #40877180 is needed as a water throughput
between the Shower Module and the Handshower Module.
Draining technique
9
Drain
The throughput of the drain must be at least 13 GPM.
6
7
Thermostatic Mixer
#10755001
A rough is required (#10754181) to install the Thermostatic Mixer.
Both parts must be ordered separately. Maximum throughput of
module is 15 GPM at 44 PSI.
4
4
5
47"
5
Shower Module
#28491001
Two Shower Modules are used for this installation. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
9
Axor ShowerCollection
Hot Water
Components
CEILING CONSTRUCTION
1 x Showerhead
#10926001
1 x Ceiling Showerarm, 10"
#26414001
1 x Thermostatic Mixer Trim
#10755001
1 x Rough, Thermostatic Mixer
#10754181
Ceiling Connector
To install Showerhead #10926001, the 10" Ceiling Showerarm
(sold separately) must be screwed into a 1⁄ 2" internal thread.
The Showerarm is then attached to the connection fitting and
fixed with screws. Lastly, the Showerhead is screwed tightly onto
the ceiling connector.
Attention: The net weight of the Showerhead is approximately
4.5 lbs. without water. Please provide an adequate ceiling
reinforcement at this point.
2 x Shower Module Trim
#28491001
PLUMBING installation
Cold Water
Mixed Water
Dimensions assume a
body height of 5'-11"
1
2
5
8
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
2
Hot Water Supply
Based on individual showering preferences as well as on the number
of users, each system must be designed on an individual basis.
Maximum Working Pressure: 110 PSI
Recommended Working Pressure: 46–70 PSI
Maximum Hot Water Temperature: 140°
Minimum Capacity Recommendation: 40 Gallons
Note: Large differences in pressure between the hot and cold
supplies must be balanced or the valve will not work properly
2 x Short Shelf
#40872000
2x Short Shelf Basic Set
#40877180
3
Supply Lines
Thermostatic Mixer: 2 x 3 ⁄4" (hot/cold)
Showerhead: 1 x 3 ⁄4" (hot/cold)
Volume Control for Shower Modules: 1 x 3 ⁄4" (mixed water)
2 x Volume Control Trim
#10972001
2 x Rough, Volume Control
#10971181
3
3
1
6
Volume Control
#10972001
Required for controlling the Showerhead. To install inline with other
modules (1⁄ 2" spacing between modules) use rough #10971181.
Both parts must be ordered separately. Maximum throughput of
module is 14 GPM at 44 PSI.
7
Handshower Module
#10651001
Installation of the Handshower Module requires the rough
#10650181. A volume control is built in. Both parts must be
ordered separately. Handshower flow rate is 2.5 GPM at 44 PSI.
Maximum throughput of module is 8 GPM at 44 PSI.
8
Short Shelf
#40872000
Since the Short Shelf is installed between two water-bearing parts,
Basic Set #40877180 is needed as a water throughput
between the Shower Module and the Handshower Module.
Draining technique
9
Drain
The throughput of the drain must be at least 13 GPM.
6
7
Thermostatic Mixer
#10755001
A rough is required (#10754181) to install the Thermostatic Mixer.
Both parts must be ordered separately. Maximum throughput of
module is 15 GPM at 44 PSI.
4
4
5
47"
5
Shower Module
#28491001
Two Shower Modules are used for this installation. Maximum
throughput is 1.0 GPM at 44 PSI per shower module.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
9
Axor ShowerCollection
PLANNING
EXAMPLE
6
30
31
Axor ShowerCollection
the PLANNING EXAMPLES
8"
Volume Control
Tub Spout
Thermostatic Mixer
In addition to creating personalized shower
installations, Axor ShowerCollection products
are well-suited for a bathtub setting with the
addition of a Tub Spout.
· The Handshower Module is installed on
the left-hand wall — easily accessible for cleaning the bathtub
· Thermostatic Mixer for the temperature control and Handshower Module are
easily accessible from outside the bathtub
· Volume Control adjusts the Tub Spout
· Tub Spout also serves as a shelf for
personal items
Handshower Module
Bathtub Solution
Bathtub Rim
Hot Water
Cold Water
Mixed Water
Axor ShowerCollection
Components
PLUMBING INSTALLATION
1 x Thermostatic Mixer Trim
#10755001
1 x Rough, Thermostatic Mixer
#10754181
Supply Lines
Thermostatic Mixer: 2 x 3 ⁄4" (hot/cold)
Volume Control for Tub Spout: 1 x 3 ⁄4" (mixed water)
1 x Handshower Module Trim
#10651001
1 x Rough, Handshower Module
#10650181
1 x Volume Control Trim
#10972001
1 x Rough, Volume Control
#10971181
1 x Tub Spout Trim
#10942001
1 x Rough, Tub Spout
#10941181
Thermostatic Mixer
#10755001
A rough is required (#10754181) to install the Thermostatic Mixer.
Both parts must be ordered separately.
Maximum throughput of module is 15 GPM at 44 PSI.
Tub Spout
#10942001
The projection of the Tub Spout is 7". This dimension must be taken into consideration
when selecting the bathtub, so that the water spray protrudes over the bathtub rim in
any event. A rough is required (#10941181) to guarantee accurate installation with a
spacing of 1 ⁄ 2" to the directly adjacent Volume Control. The Tub Spout is controlled via
the Thermostatic Mixer, in conjunction with a separate Volume Control.
Volume Control
#10972001
Required for controlling the Tub Spout. To install inline with other modules (1⁄ 2" spacing
between modules) use rough #10971181. Both parts must be ordered separately.
Maximum throughput of module is 14 GPM at 44 PSI.
Handshower Module
#10651001
Installation of the Handshower Module requires the rough #10650181. A volume control
is built in. Both parts must be ordered separately. Handshower flow rate is 2.5 GPM at
44 PSI. Maximum throughput of module is 8 GPM at 44 PSI.
Detailed installation instructions are included with the respective products and
can also be downloaded from www.hansgrohe-usa.com
Axor ShowerCollection
32
33
Concepts for
Individual Planning
You can use the flexible modular system of the Axor
Shower­Collection to create your own individual shower
areas. The following illustrations show possible ideas
for the concept of your personal well-being zone.
For All Sizes: The Shower Module is worked into an adjustable
metal escutcheon. A simple sliding motion will change the
jet angle of the shower. This example shows the installation
with the jets at a vertical adjustment. Depending on the
user's needs and body height, this can easily be adjusted.
Light, sound
Showers
Function
Showers
Light
Sensual Arrangement for Body and Mind!
The Light Modules ensure a mood-pleasing lighting of the shower.
Ideally, these are arranged close to the ceiling or close
to the floor. The Speaker Modules are also at head level.
The shower and temperature control are always within reach.
Larger Areas or One Point: If the Shower Module is
rotated by 90° during the installation, the water jets can
be adjusted horizontally. This is useful when the Shower
Modules are installed in a corner. By altering the angle,
the jets either hit a certain point or a larger area of the body.
The Leading Shower System for Your Wellbeing:
All functions of the controls are arranged vertically. Shelves
are arranged on a horizontal level, providing immediate
access to shower supplies. The body showers are also
arranged horizontally, one pair each for the neck and the
back, as well as at the height of the thighs.
Showerhead on Demand: When installed in the
ceiling, the Shower Module becomes a showerhead.
The connection of several modules to each other creates
a larger showerhead area. The combination of the
controls and fittings lets you assign the jets as desired.
Axor ShowerCollection
Inspirations for Creative
Showering Solutions
With the endless possible combinations that the
Axor ShowerCollection has to offer, individual
requirements can be realized in a creative manner.
The following installation inspirations show how
space and function, design and architecture,
always work together.
Sitting Down Relaxed: The seating area integrated in this shower
is equipped with neck and back massaging jets. The lower Shower
Modules provide a loosening calf massage. For a refreshing rain
shower, stand up and let the Showerhead spoil you. The laminar spray
of the Handshower Module can be used for water therapy applications.
1
2
3
34
35
Simply Logical: All shower functions are logically controlled
by the centrally-located Thermostatic Module. The upper Volume
Control controls the Showerhead (1). Below it is the control
for the upper body shower (2). The third valve regulates the two
lower body showers (3).
For Large Solutions: The Axor Starck ShowerCollection also
lets you realize elaborate solutions for any type of wellness area.
Its balanced symmetry is shown in this example, where two showers
are combined into one unit. The controls are arranged side by side
for each respective shower.
Switch on. Step in. Relax! The Thermostatic Module
is located in the entrance area of the shower. Thus, the correct
shower temperature can simply be adjusted from the outside — even with the water running and without getting wet. The separately
controlled Handshower Module is installed on the side.
Showering in the Bathtub. With the addition of the Tub Spout,
Axor ShowerCollection is well-suited for bathtub solutions. The individual
elements of the collection can be easily integrated into bathtub concepts.
Practical and elegant, the Thermostatic Module is used to adjust
the correct bath temperature. Note: Observe installation guidelines.
Axor ShowerCollection
the INSTALLATIONS
The Modular Installation Principle
The modular system evident in the positioning of the trims is complemented by an
equally well-considered installation system behind the wall. The unique mounting
system for the roughs, plus several installation aids are available to ensure precise
spacing between modules. These enable the individual modules
to be installed accurately in a perfect line.
· Roughs can be easily inserted into each other
· Trims are installed using consistent 1 ⁄ 2" spacing
· No distortion or detaching of the roughs — thanks to roll pins
· Optimal flow of water inside the roughs
Axor ShowerCollection
36
37
Axor ShowerCollection
the INSTALLATIONS
Mixing Valves/Shower Modules/Accessories
Installation in a Vertical Line
01
Below we explain how to install the Mixing Valves, Shower Modules
and the accessories from Planning Example 1 in a vertical line.
Unscrew the pre-installed plugs
from the top and bottom of the
Thermostatic Module rough.
02
03
Install the Volume Control
Valve rough at the top of
the Thermostatic Module rough
and secure with locking pins.
Install the Shower Module
rough at the top of the
Volume Control rough and
secure with locking pins.
04
05
Install the Shower Module
rough at the bottom of the
Thermostatic Module rough
and secure with locking pins.
Install the Handshower Module
rough at the bottom of the
Shower Module rough and
secure with locking pins.
Note: Installation information provided in this brochure is intended as a general aid for bathroom planning only. For detailed technical installation instructions, please visit www.hansgrohe-usa.com.
Axor ShowerCollection
06
07
Screw in plugs in the
shown positions.
Attach the Mounting Plate
to the Shower Module rough
from behind. Screw the
integrated wall sockets for
the Speaker and Light Modules
to the Mounting Plate.
08
09
Align the pre-installed rough in
the unfinished wall and affix.
The fitting must be piped,
flushed and tested. Cement the
rough into the wall surface.
Fill the seams with silicone.
38
39
10
11
Install a sealing collar and
press into the glue and the
silicone below.
Cut all construction protection
pieces off 1 ⁄16" in front of
the tiles.
Axor ShowerCollection
the INSTALLATIONS
12
13
Screw in the threaded sleeves
and shorten to 1 ⁄ 2" from
the wall. All elements must
now be sealed with silicone
toward the wall.
Insert the threaded adapter
and shorten to 1" from the
wall surface.
14
15
Remove the flushing block
and install the Thermostatic
Module unit into the
Thermostatic Module rough.
Install and fasten the
threaded adapter and
the handle stop. Install the
chrome-plated sleeve.
Install the cover plate of
the Thermostatic Module.
16
17
Screw the three handle sleeves
onto the threaded sleeve kit of
the Thermostatic Module and
then insert the handles. Install
the thermostatic handle and
tighten the fastening screws.
Screw the handle sleeve
onto the threaded sleeve kit
of the Volume Control and
then attach the handle.
Note: Installation information provided in this brochure is intended as a general aid for bathroom planning only. For detailed technical installation instructions, please visit www.hansgrohe-usa.com.
Axor ShowerCollection
18
19
Pre-install the water guide
of the Handshower Module.
Position the pre-installed unit
and screw the handle sleeve
onto the threaded sleeve kit
of the Handshower Module,
then install the handle.
Screw the 1⁄ 2" connection
into the Shower Module rough.
Then affix the Shower Module
cartridge to the 1⁄2" connection.
Then install the cover plate
on the cartridge using socket
head screws.
20
21
Align the borings for the
Short Shelf by means of
a drilling template. Install
the fixation plate on the
wall. Install the shelf on
the fixation plate.
Install the Speaker Module
and secure it to the rough
using four screws. Then install
the cover.
22
23
Route a secondary line from
the transformer to the rough.
Connect the plugs, Light
Module and the secondary
cable. Insert the Light Module
and fasten using four screws.
After that, pre-adjust the readyto-use kit using grub bolts
and then hook them in and
secure them.
Perform a functional test.
40
41
Axor ShowerCollection
the INSTALLATIONS
ShowerHeaven Installation
01
This explains the installation of the ShowerHeaven
(28 x 28 inches) step by step, as shown in Planning Example 1.
To install the ShowerHeaven, you need a suspended
intermediate ceiling. The frame of the ShowerHeaven can
be installed in the pre-construction phase.
Prior to installation, the
ShowerHeaven must be
disassembled. The cylinder
screws must be loosened and
the four bearing bolts must
be pulled out. The dimensions
of the ceiling connections
must be 7" from the center of
the ShowerHeaven. Hold the
frame to the desired ceiling
location and align accordingly.
Mark the boring placement.
02
03
Drill the borings with
a diameter of 5 ⁄16". Every boring
has to be fitted with
a dowel. Screw in the hanger
bolts and attach the frame
to the ceiling using washers
and nuts (SW 1 ⁄ 2").
Screw in the T-pieces and
angle cleats. Install the
functional unit using bearing
bolts and cylinder screws.
04
05
Connect the equipotential
bonding and the ground to
the frame.
Secure the functional unit
to the long carabine hook.
Screw the pressure hoses
to the ceiling connectors.
Note: Installation information provided in this brochure is intended as a general aid for bathroom planning only. For detailed technical installation instructions, please visit www.hansgrohe-usa.com.
Axor ShowerCollection
06
07
Fold the functional unit
upward and secure with
the short carabine ­hook.
Examine hose connections
for tightness. Install the
functional unit using
bearing bolts and cylinder­
screws. Install the
intermediate ceiling.
Hook the decorative plate
on the three bowden cables
using carabine hooks.
08
09
Insert the decorative plate
into the pre-mounted centering
sleeves and secure with
counter-sunk screws.
Remove the centering sleeves.
42
43
10
11
Secure the decorative plate
using counter-sunk screws.
Perform a functional test.
Axor ShowerCollection
the INSTALLATIONS
Shower Modules for Ceiling Installation
01
In addition to their installation for a body or a neck shower, the
Shower Module can also be combined with several others into
a showerhead. In this case, 6 Shower Modules are combined.
Adapt the Mounting Plate
to 6 Shower Modules.
02
03
Pipe the connectors and
install the threaded bars
into the ceiling to secure
the Mounting Plate.
Hold the Mounting Plate with
the piping against the desired
location on the ceiling and
screw it on using the threaded
bars and align it. After that,
check the lines for leaks.
04
05
Install the intermediate
ceiling and prepare the
6 borings for the 1 ⁄ 2"
connectors. After that,
screw the 1 ⁄ 2" connectors
into the Mounting Plate.
Align the Shower Modules
with the flat side of the
1
⁄ 2" connectors.
06
07
Secure the Shower Module
cartridges to the 1 ⁄ 2"
connectors. Then install the
cover plate on the cartridge
and secure by loosening
the socket head screws.
Perform a functional test.
Note: Installation information provided in this brochure is intended as a general aid for bathroom planning only. For detailed technical installation instructions, please visit www.hansgrohe-usa.com.
Axor ShowerCollection
44
45
Axor ShowerCollection
CLEANING INSTRUCTIONS
01
02
03
04
05
06
07
08
The Showerhead
is Easy to Clean
The metal cover of the Showerhead
(10 x 10 inches) is easy to remove and
can conveniently be cleaned by hand
or in the dishwasher. Please note our
cleaning recommendations in the
installation manual or on our website.
Axor ShowerCollection
46
47
Axor ShowerCollection
PRODUCT OVERVIEW
Showers
2
4
9½"
20⅞"–22¾"
1⅛"
4¾"
1
1¾"
9½"
16⅛"–18"
⅞"
9½"
1"
½"
G½
28⅜"
20⅝"
9⅝"
5
28⅜"
3
4¾"/4¾"
2⅝"
2¼"
4"
3⅜"
10¾"
1⅛"/1⅛"
2⅜"
½" NPT
3"
1 12 "
⅜"
⅞"
NPT ½"
4⅝"
G½
2⅜"
4"
Showers
1 ShowerHeaven
Part No. 10625, -801, -821
2 Showerhead
Part No. 10926, - 001, -821
4 Wall-Mounted Showerhead Trim with Showerarm
Part No. 10925, - 001, -821
3 Ceiling Showerarm, 10"
Part No. 26414, - 001, -821
5 Rough, Wall-Mounted Showerhead
Part No. 10921181
Finish: Chrome (- 000, - 001), Polished Stainless Steel (-801), Brushed Nickel (-820, -821)
Axor ShowerCollection
4¼"
5"
7
9
4¾"
1"
1⅛"
4¾"
½"
6¼"
4¾"
6
48
49
6⅞"
13¾"
8
10
4¼"
3⅛"
G½
1⅝"
¾
6"
4"
¾" NPT
½
6"
5⅜"
2¾"
3⅜"
1¾"
4¼"
3⅛"
G¾
Installation Aid
6 Shower Modules Mounting Plate
Part No. 28470181
7 Shower Module Trim
Part No. 28491, - 001, -821
9 Handshower Module Trim
Part No. 10651, - 001, -821
8 Rough, Shower Module*
Part No. 28486181
10Rough, Handshower Module
Part No. 10650181
* Needs Rough if installed
adjacent to other modules
Axor ShowerCollection
PRODUCT OVERVIEW
Thermostatic Modules/Valves
3
5
14⅛"
4¾"
2
¾"
4¾"
1⅜"
4¾"
4¾"
2"
4¾"
3½"
Ø 1⅞"
1
4¾"
¾" NPT
2¾"
14⅜"
4
6
5½"
4¼"
¾" NPT
5¼"
3⅛"
4¼"
3⅜"
G½
3⅛"
G¾
Thermostatic Modules
1⅝"
6"
3½"
4⅛"
¾" NPT
3¾"
¾" NPT
G¾
3¾"
3¾"
G¾
Valves
1 Thermostatic Module Trim
Part No. 10751, - 001, -821
3 Thermostatic Mixer Trim
Part No. 10755, - 001, -821
5 Volume Control Trim
Part No. 10972, - 001, -821
2 Rough, Thermostatic Module
Part No. 10750181
4 Rough, Thermostatic Mixer
Part No. 10754181
6 Rough, Volume Control
Part No. 10971181
Finish: Chrome (- 000, - 001), Polished Stainless Steel (-801), Brushed Nickel (-820, -821)
Axor ShowerCollection
Diverters/Tub Spout
9½"
4⁹⁄₁₆"
9½"
¾"
4⁹⁄₁₆"
7"
7⅛"
G¾
2⅜"
4¾"
4¾"
G¾
2⅜"
4¾"
4¾"
Ø 2"
4¾"
1⅞"
2⅝"
4¾"
10
7
7"
7⅛"
50
51
8
11
9
¾" NPT
¾" NPT
3¼"
4⅜"
1⅛"
2⅜"
2⅜"
3¾"
¾" NPT
¾" NPT
2⅜"
¾" NPT
G½
1⅛"
3¾"
2⅜"
G¾
6⅜"
¾" NPT
¾" NPT
10¾"
Diverters
7 Trio/Quattro Diverter Trim
Part No. 10932, - 001, -821
Tub Spout
8 Rough, Trio 2-Way Diverter
Part No. 15984181
9 Rough, Quattro 3-Way Diverter
Part No. 15930181
10 Tub Spout Trim
Part No. 10942, - 001, -821
11 Rough, Tub Spout
Part No. 10941181
Rough, Trio 2-Way Diverter with Shut-off
Part No. 15981181
Rough, Quattro Green 3-Way Diverter
Part No. 15936181
Axor ShowerCollection
PRODUCT OVERVIEW
Accessories
2
4¾"
4¾"
4¾"
2¾"
4¾"
1
3½
1⅛"
Ø 2⅞
⅞
4
⅞"
5¾"
2⅜"
½"
2⅜"
2⅜"
22⅜"
3
3⅜"
4½"
2⅜"
4⅜"
4¾"
Accessories
1 Speaker Module
Part No. 40874, - 001, -821
Installation Aid
3 Basic Set for Light/Speaker Modules
Part No. 40876180
2 Light Module
Part No. 40871, - 001, -821
Finish: Chrome (- 000, - 001), Polished Stainless Steel (-801), Brushed Nickel (-820, -821)
Axor ShowerCollection
4 Mounting Plate
Part No. 10973180
Required to install
Basic Set #40876180
4¾"
9½"
⅞"
½"
½"
4¾"
7
4¾"
5
⅞"
4"
4"
52
53
G¾
2⅛"
G½
4"
2"
2⅜"
G½
8
6
6"
10⅜"
1⅜"
10¾"
G¾
2¾"
Accessories
5 Short Shelf
Part No. 40872, - 000, -820
7 Long Shelf
Part No. 40873, - 000, -820
6 Basic Set for Short Shelf
Part No. 40877180*
8 Basic Set for Long Shelf*
Part No. 40878180
*The Basic Set for the shelves is only necessary between water-bearing parts
Axor ShowerCollection
PROJECT REFERENCES
Sunseeker Predator
This 125-foot luxury yacht from Sunseeker, based
in southern England, provides first-class comfort for
up to 10 passengers. The interiors are tailored to
the owner's requirements. Products from Axor
ShowerCollection with Philippe Starck emphasizes
this individuality and shows that it is possible to
design your own personal spa in a compact space.
Builder: Sunseeker International Limited, Poole, UK
Budersand Hotel Golf & Spa, Sylt
Guests at the exclusive Budersand Hotel Golf & Spa
on the southern coast of Sylt are greeted by this
luxurious spa. The centerpiece of the facility
is the colorful, illuminated swimming pool with
its clear ocean view. The 'experience shower' gives
Axor ShowerCollection with Philippe Starck its
special flair — crowned by the ShowerHeaven.*
The 21 rooms and suites are equipped with the
Axor Citterio collection.
Architects: Dierks, Kunze & Oevermann (dko), Berlin, Germany
Interior Designer: Jan Wichers, Hamburg, Germany
*ShowerHeaven with lights not available in the US
Axor ShowerCollection
CONTENTS
04
10
36
48
54
The Modular Principle
The Planning Examples
The Installations
Product Overview
Project References
PHILIPPE STARCK
Philippe Starck is one of the best known creative minds of our time.
Many people regard him as having a streak of genius, which regularly
provokes with its playful, often spectacular style.
· Interior and general designer
· Born in Paris, France, in 1949
· Founded the company ”Starck Product“ in 1979
· His partners include Kartell, Alessi, Duravit, Driade, Fossil and Cassina
· Projects: yoo Apartments, motor yacht A, Café Costes in Paris,
Hotel St. Martins Lane in London
· Collaboration with Axor since 1992
Axor ShowerCollection with Philippe Starck
0
55870 39473
5
CA—Axor ShowerCollection Professional Brochure . Part No. MKT-12-137E . Printed October 2012
Subject to technical alterations and color discrepancies
Information and Inspiration for Professionals
To obtain more information on Axor products, call toll-free:
800-334-0455
www.hansgrohe.ca