Elite SL-3000-UL Series Gate Opener Instruction
Transcription
Elite SL-3000-UL Series Gate Opener Instruction
Installation Instructions Regarding the Gate Operator A) Install the gate operator only when: 1) The operator is appropriate for the construction and the usage Class of the gate. 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 1/4inch (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. 3) All exposed pinch points are eliminated or guarded, and 4) Guarding is supplied for exposed rollers. B) The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. C) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. D) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. E) F) Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line of sight of the gate outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. G) All warning signs and placards must be installed where visible in the area of the gate. H) For a gate operator utilizing a non-contact sensor such as a photo beam: 1) See instructions on the placement of non-contact sensor for each Type of application, 2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate still moving, and 3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. I) For a gate operator utilizing a contact sensor such as an edge sensor: 1) One or more contact sensors shall be located at the leading edge, trailing edge and postmounted both inside and outside of a vehicular horizontal slide gate. 2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. 5) A wireless contact sensor such as the one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. Important Safety Instructions WARNING - To Reduce the Risk of Injury or Death: 1. READ AND FOLLOW ALL INSTRUCTIONS! 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate while the gate is in operation. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE. 4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator, Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the emergency release only when the gate is not moving. Make sure the power for the gate operator is off. 6. KEEP GATES PROPERLY MAINTAINED. Read the manual. Have a qualified service person make repairs to the gate or gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS. Gate – A moving barrier such as a swinging, sliding, raising lowering, rolling, or like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. Vehicular horizontal slide-gate operator (or system) – A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like. Residential vehicular gate operator – Class I – A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith. Class I Commercial/General access vehicular gate operator – Class II – A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public. Class II Commercial/General access vehicular gate operator – Class III – A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. Class III Restricted access vehicular gate operator – Class IV – A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. Class IV IMPORTANT! Because gate coasting distance varies with temperature, Elite DOES NOT recommend the installation of a catch post. This could cause the gate to collide with the post. Correct Installation with Catch Rollers Incorrect Installation using a Catch Post! Gate in Fully Opened Position Guide Rollers (Elite Part # A UHM) Gate Clearances 1/4" Clearance from Top of Gate Catch Rollers 1/2" Clearance Between Gate and Rollers Wall Minimum Clearance of 5" Between Back of Gate and Wall or Other Objects in Gate's Path Gate For safety reasons, a physical stop MUST be installed on the gate prior to installation of the gate operator. This will assure that the gate does not exceed movement limits and derail while in motion. CAUTION IMPORTANT NOTICE! Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner. Also the warning sticker should be placed on the operator so it is clearly visible. Warning Signs on Both Sides of Gate Warning Sign Clearly Visible on Gate Operator Owners Must Never Let Pedestrians Cross the Path of a Moving Gate! CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall! CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate! CAUTION Warning Signs on Both Sides of Gate 3" Maximum Picket Width 2"x 2" Mesh Wire Across Entire Gate Guide Rollers Guide Rollers Over-Travel Stops on Both Ends of Gate Rail Steel V-Groove, High Speed Ball Bearing Wheels Warning Sign Clearly Visible on Gate Operator 115 VAC for Each Gate Operator Reinforced Concrete to Bolt Operator on U.L. Listed Underground Conduit for Wires Pedestrians MUST have a Separate Walkway! SL-3000-UL-DM SL-3000-UL Two-1/2 hp Motors, 120 VAC, 4.7 amp. Maximum Gate Length – 37 feet Maximum Gate Weight – 800 lbs. 1/2 hp Motor, 120 VAC, 4 amp. Maximum Gate Length – 37 feet Maximum Gate Weight – 1000 lbs. SL-3000-UL-1HP Two-1/2 hp Motors, 120 VAC, 8.4 amps. Maximum Gate Length – 37 feet Maximum Gate Weight – 2000 lbs. Be sure to read and follow all Elite and UL instructions before installing and operating any Elite products. Elite Access Systems, Inc. is not responsible for improper installations or failure to comply with local building codes. It is highly recommended installing over-travel stops at both ends of the gate rail in any type of installation, to prevent derailing. FRONT INSTALLATION Reason: Cost effecient Over-Travel Stop Over-Travel Stop REAR INSTALLATION Reason: Chain is not visible Over-Travel Stop Idler Wheel must have Safety Cover Over-Travel Stop CEILING MOUNT UNDERGROUND Reason: Space effecient/chain is not visible FRONT INSTALLATION Weld front bracket with gate in open position. Weld rear bracket with gate in closed position. REAR INSTALLATION Cut the cover 17 1/2 inches high. Make sure the idler wheel has a safety cover. REAR INSTALLATION COVER MODIFICATION Cut the chain access slot on the one side of the cover to the exact specifications. 17.5" 2" Important: For safe operation of the gate opener do not cut the slots any wider or longer than shown. DO NOT modify the housing in any way other than specified. C O N C R E T E P A D A N D G A T E A T T A C H M E N T Follow gate manufacturers specifications and local building codes for setting post. 12" 12" Above Ground 6" 10" Below 24" Ground 8" 24" 24" Concrete (Reinforced Recommended) Suggested installation for dirt ground. The measurements depend on the type of ground (ie., asphalt, cement, dirt) Red Head Fastener 1/2" x 3 1/2" Over-Travel Stops on Both Ends of Rail Cover over Wheel Rear Installation Over-Travel Stops on Both Ends of Rail Front Installation G A T E A N D O P E R A T O R D I S T A N C E 4" Minimum Distance Between Gate and Sprocket Correct Installation C H O O S I N G Omni Control Board CENTER SAFETY Incorrect Installation M O V E M E N T D I R E C T I O N Open to the Left MER 60 EXIT 1 OFF 3 ON DC-BACKUP W4 GB A MS LINK SYSTEM ON SENSORS TIMER 13 13 OFF 60 ON 3 13 POWER OVERLOAD OPEN LEFT OPEN RIGHT OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE RADIO GATE OPEN RECEIVERLOCKED EXIT LOOP SAFETY CENTER RESET MOTOR LOOP LOOP RADIO Open to the Right Omni Control Board MER 60 CENTER 1 OFF SAFETY EXIT 3 ON DC-BACKUP W4 GB A MS LINK OPEN LEFT RADIO OPEN RIGHT SYSTEM ON SENSORS TIMER 60 13 13 OFF ON 3 13 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE RADIO GATE OPEN RECEIVER LOCKED EXIT LOOP SAFETY CENTER RESET MOTOR LOOP LOOP POWER OVERLOAD H O W T O C O N N E C T P O W E R Do Not Use This Outlet Unless You Are An Authorized Service Technician Minimum: 15-Amp Breaker Switch Per Operator Required Suggestion: Seal all open holes of electronic box with sealant when finished wiring. White Wires (Neutral) Use U.L. Listed Conduit for Supplying Power to the Unit Black Wires (120 VAC) Green Wires (Ground) WIRE GUAGE REQUIREMENT FOR 120 VAC POWER SUPPLY: 1/2 HP AND DUAL MOTOR ONLY 16 Gauge 150 Feet 14 Gauge 250 Feet 12 Gauge 400 Feet 10 Gauge 650 Feet 8 Gauge 1000 Feet 4 Gauge 2200 Feet Caution: ELITE ACCESS SYSTEMS, INC. is not responsible for conflicts between the information listed in the above chart and the requirements of your local building codes. The information is for suggested use only. Check your local codes before installation. Gate Operator MUST be properly grounded. A D J U S T I N G G A T E T R A V E L I N G D I S T A N C E Nut Push Plate Plate Each notch indicates an estimated 1 inch of gate travel Before Adjusting, Do the Following: 1.Turn the Power OFF! 2. Push the plate inward. Roll the nut to the direction desired. 3. Place the plate back in the notch. 4. Turn the machine off. 5. If you need more adjusting, repeat the process. Adjusted by Qualified Service Personnel CENTER SAFETY EXIT Maximum Sensitivity 1 3 DC-BACKUP W4 G B A SYSTEM ON MS LINK TIMER SENSORS 60 3 1 POWER 3 1 OFF 1 OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT STRIKE OPEN RADIO RECEIVER EXIT SAFETY CENTER RESET LOOP MOTOR LOOP LOOP Minimum Sensitivity GATE LOCKED FIRE DEPT. DO NOT Touch Alarm Sensor The level of sensitivity has to do with the weight of the gate and the condition of installation. Too sensitive = if the gate stops or reverses by itself. Not sensitive enough = if the gate hits an object and does not stop or reverse. CAUTION: If the power supply to the gate operator is less than 99 volts, adjust the alarm by turning the alarm adjustment counter-clockwise enough to actuate the alarm when obstructed but not sensitive enough for false triggering to occur. A D J U S T A B L E T I M E R Timer ON TIMER CENTER SAFETY 60 EXIT OFF ON OPEN LEFT 3 1 Set Timer 1 to 60 seconds 3 OPEN RIGHT DC-BACKUP W4 GB MS LINK A SYSTEM ON TIMER SENSORS 60 3 1 OFF 1 3 1 ON 3 POWER OVERLOAD TIMER 3 OPEN LEFT 60 3 OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OFF OPEN LEFT Timer can be set from 1 to 60 seconds (Timer ON ), or for push open/push close type operation (Timer OFF ). 1 3 ON OPEN RIGHT Timer OFF M A S T E R A N D S L A V E W I T H T I M E R O N Master Omni Board Primary Control for System Master and Slave Boards are Interchangeable Use Low Voltage Wires to Connect Gate Operators Together Caution: 115 volts per operator required Master Omni Board TIMER CENTER SAFETY OFF EXIT OPEN LEFT 60 ON 3 1 3 Adjust Time Desired 0 to 60 seconds Slave Omni Board OPEN RIGHT CENTER DC-BACKUP GB A SYSTEM ON MS LINK TIMER SENSORS 60 3 1 OFF 1 3 1 SAFETY EXIT Master Timer “ON” W4 POWER OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT DC-BACKUP FIRE STRIKE RADIO GATE DEPT. OPEN RECEIVER LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR W4 G B A SYSTEM ON SENSORS MS LINK TIMER POWER 60 3 OVERLOAD 13 13 OFF 13 ON OPEN LEFT W4 G B A Use Shielded Twisted Wires to Connect Gate Operators Together MS LINK OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR W4 MAXIMUM Counterclockwise Setting G B A MS LINK TIMER 1. Connect G from master to G of slave. (G is the shield or a ground wire) OFF 2. Connect B from master to B of slave. OPEN LEFT 3 60 ON 1 3 OPEN RIGHT 3. Connect A from master to A of slave. 4. Turn timers on BOTH Omni boards to the “ON” position 5. Turn the SLAVE Timer adjustment all the way Counterclockwise 6. Use MASTER timer ONLY to select the desired time Slave Timer “ON” M A S T E R A N D S L A V E W I T H T I M E R O F F Use Low Voltage Wires to Connect Gate Operators Together Master Omni Board CENTER SAFETY Caution: 115 volts per operator required TIMER EXIT 60 3 Slave Omni Board OFF DC-BACKUP ON OPEN LEFT 1 3 OPEN RIGHT W4 CENTER GB SAFETY EXIT A SYSTEM ON MS LINK TIMER SENSORS 60 3 1 OFF 1 3 1 POWER OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR DC-BACKUP W4 G B A MS LINK SYSTEM ON SENSORS TIMER POWER 60 3 OVERLOAD 13 13 W4 G B A Use Shielded Twisted Wires W4 to Connect Gate Operators Together MS LINK ON OPEN LEFT OPEN RIGHT STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR G B A MS LINK 1. Connect G from master to G of slave. (G is the shield or a ground wire) 2. Connect B from master to B of slave. 3. Connect A from master to A of slave. 4. Turn timers onBOTH Omni boards to the “OFF” position P A R T I A L OFF 13 FIRE DEPT. TIMER OFF OPEN LEFT M A S T E R / I N D I V I D U A L 60 ON 3 1 3 OPEN RIGHT C O N T R O L IN ORDER FOR THE FOLLOWING OPERATION TO OCCUR, FOLLOW THE INSTRUCTIONS. EXAMPLE: There is a double gate, the entry gate is to be opened with a radio transmitter and the exit gate with a free exit loop. Only one safety loop system is to open both gates, and a fire department switch should open both gates at the same time. 1. Connect the radio receiver to entry gate only. 2. Connect the exit loop to exit gate only. 3. Connect the safety loop to both entry and exit gates. 4. Connect the fire department switch to both entry and exit gates. S O L E N O I D / M A G L O C K J 3 C O N N E C T I O N Wire Harness J3 2 CENTER SAFETY 1 3 Normally Closed 8 7 Common 10 9 EXIT Normally Open DC-BACKUP W4 G B A MS LINK SYSTEM ON SENSORS TIMER 60 POWER 3 OVERLOAD 1 OFF 1 3 1 3 ON Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit. 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Solenoid Lock Solenoid Lock J3 2 1 3 8 7 10 9 #3 Normally Closed Ground Plug-In Transformer #7 Common Wire Nut Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness) Power Ground Magnetic Lock Magnetic Lock J3 2 1 3 8 7 10 9 Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) Plug-In Transformer Ground #7 Common Wire Nut #8 Normally Open Power Ground QCC socket with QCC access ID inserted QCC “Mode of Operation” switch QCC A B DC-BACKUP OPEN STOP CLOSE MAGLOCK ALARM ARMED M/S LINK QCC W4 G B A OPEN A MS LINKCLOSE STOP B MAGLOCKALARMARMED SYSTEM ON M/S LINK TIMER SENSORS 60 1 3 1 POWER 3 1 OFF OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Omni Option Board Elite Part # O-OMNI EXB QCC is designed for slide gate operators only! 1 & 2 – Open Command 10 & 11 – Burglar Alarm Output 3 & 4 – Stop Command 12 & 13 – Burglar Alarm Input 14 – Ground 5 & 6 – Close Command Master/Slave RS485 15 – B 7 – Common 8 – Normally Closed Maglock or Solenoid 16 – A 9 – Normally Open Q C C ( Q U I C K QCC Access ID (Top Positive) C L O S E C U R C U I T ) QCC Access Socket Mode of Operation Switch QCC Access ID Elite Part # O-QCC OMNI Omni Option Board Elite Part # O-OMNI EXB the QCC can operate in two different modes. The mode of operation will depend on the switch on the Omni option board. Mode A (switch off) If the gate is closing while a car is driving over the safety loop detector, the QCC will stop the gate for a second then open the gate while the car is over the safety loop detector. As soon as the car leaves the safety loop, the QCC will resume closing the gate. Mode B (switch on) If the gate is closing, and a vehicle drives over the safety loop, the QCC will stop the gate. It will not open the gate. After the vehicle leaves the safety loop, the QCC will close the gate. SE MAGLOCK 7 – Common 8 – Normally Closed AL 9 – Normally Open Solenoid Lock CENTER SAFETY EXIT 7 8 9 Ground DC-BACKUP Plug-In Transformer QCC W4 GB A A B MS LINK OPENST OP CLOSE MAGLOCKALARMARMED M/S LINK SYSTEM ON TIMER SENSORS 60 3 1 OFF 1 3 1 POWER OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Wire Nut Power Omni Option Board Elite Part # O-OMNI EXB Ground SE CENTER SAFETY MAGLOCK 7 – Common 8 – Normally Closed AL 9 – Normally Open EXIT 7 8 Magnetic Lock 9 Ground DC-BACKUP QCC W4 GB A A MS LINK OPENST OP CLOSE B MAGLOCKALARMARMED M/S LINK SYSTEM ON TIMER SENSORS 60 3 1 OFF 1 3 1 3 ON 3 OPEN LEFT Omni Option Board Elite Part # O-OMNI EXB POWER OVERLOAD OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Wire Nut Power Ground Plug-In Transformer M A S T E R / S L A V E W I T H O P T I O N A L ED CENTER SAFETY M/S LINK G EXIT B O A R D B A DC-BACKUP QCC W4 GB A A MS LINK OPENST OP CLOSE B SYSTEM ON MAGLOCKALARM ARMED M/S LINK TIMER SENSORS 60 3 1 OFF 1 3 1 3 OPEN LEFT H O U S E POWER OVERLOAD 3 ON OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Use this socket (M/S LINK) if the Omni option board is being used, and Master/Slave option is needed. A L A R M / P R O X I M I T Y Omni Option Board Elite Part # O-OMNI EXB QCC A OPEN STOP CLOSE B MAGLOCKALARM ARMED M/SLINK 10 CENTER SAFETY S W I T C H 11 12 13 EXIT DC-BACKUP QCC W4 AB A P C L O S E MAGLOCKALARMARMED OGP EBN S T O M/S LINK MS LINK SYSTEM ON SENSORS TIMER 60 POWER 3 OVERLOAD 13 13 OFF 13 ON OPEN LEFT Use Low Voltage Wire 20 AWG OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OmniControl Board 12VDC House Alarm System Dry Contact 2" Max. House Alarm Proximity Switch Elite Part # A PRS CENTER SAFETY CAUTION: EXIT Use different frequencies for every single loop detector. Turn off gate operator (from switch on electrical box) during installation. DC-BACKUP W4 G B MS LINK A SYSTEM ON TIMER SENSORS 60 1 OFF 1 3 1 POWER 3 OVERLOAD 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Wire-Loop “Safety Loop” Elite Loop detectors needed to do this function. Elite Part # A ELD Wire-Loop “Exit Loop” Omni Option Board Needed OPEN STOP CLOSE CENTER 1 2 3 4 5 SAFETY EXIT 6 DC-BACKUP QCC W4 G B OPEN MS LINK STOP A A CLOSE B MAGLOCK ALARMARMED M/ S LI NK SYSTEM ON TIMER SENSORS 60 3 POWER OVERLOAD 1 OFF 1 3 1 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR W4 Three Push Button System (OPEN-STOP-CLOSE) Step 1 - Cut off jumper wire #W4. Step 2 - Install Omni option board. Step 3 - Connect OPEN push button to # 1 & 2. Step 4 - Connect STOP push button to # 3 & 4. Step 5 - Connect CLOSE push button to # 5 & 6. Note: If using the Master/Slave board configuration, unplug the Master/Slave link plug on main board and connect it into the Omni option board M/S link socket. CAUTION: Make sure each push button is dry contact and there are no jumper wires between them. 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR OPEN 1 3 ON MADE IN USA STOP 3 1 OFF CLOSE Terminal 8 = Ground (-) Terminal 10 = 24 DC (+) 1 REVERSE SENSOR Output Power COMMAND PROCESSED ALARM SENSOR TERMINAL INPUT CONNECTIONS 1 2 3 4 5 6 7 8 9 10 Fire or Any Key Switch Radio Receiver Output Power Card Reader Terminal 8 = 24 Volt Terminal 9 = Relay Terminal 10 = Radio Power External “Exit” Loop Detector Push Button Photo Cell 1 4 7 HELP 2 3 5 6 8 9 Phone Entry 0 External “Safety” Loop Detector S A F E T Y L O O P S Y S T E M The safety loop prevents the gate from closing while a car or any other object remains in the gates pathway. 4' 4' 4' Twisted Wires 4' From Loop Cut 4' 1/4" 1 1/2" 4' Typical Fill Loop Cuts with Proper Sealer E X I T L O O P Three Wire Layers in Loop Cut S Y S T E M The exit loop automatically allows the gate to open when a car is exiting. 4' Twisted Wires 4' From Loop Cut 4' 4' 4' 1/4" 1 1/2" 4' Typical Fill Loop Cuts with Proper Sealer Three Wire Layers in Loop Cut E M E R G E N C Y R E L E A S E Standard Manual Crank Cover 1. Turn the power OFF! 2. Make sure the crank tool fits the crank input, as shown above: Turn the crank to open the gate. To speed up the process you may use a wireless power drill (6 ”/sec). Option 1: Elite Part # CP-17 Pull firmly on the “T” Handle to release the chain. Turn the power OFF to the gate operator and unlock the fire box. The chain is held in place by a spring loaded pin. Option 2: Elite Part # DC-1000U-SL Condition A: In case of power failure the gate opens automatically one time and stays open. when power is restored the operator returns to normal condition. Power Back-Up Condition B: In case of power failure the gate will not open automatically until activated by a key switch or push button. for More Details contact your Local Dealer R E P L A C I N G T H E C O N T R O L B O A R D Disconnect 2 wire harnesses from OmniControl board. Unscrew 3 nuts to remove board. A U D I O A L A R M When one of the following events happensTwice Consecutively, an Alarm will Sound! To turn alarm off, cut the power or use the optional stop button. Refer to “Stop Button Alarm” 1 The gate is too heavy. 2 Objects are on the gate's track such as mud, rocks dirt, etc. 4 The gate has one or more broken wheels. 3 The gate is hitting a wall or any other object. 5 A moving object has hit the gate and the gate is off the track. Refer to the Troubleshooting Table S T O P B U T T O N A L A R M S H U T - O F F Omni Option Board Needed OPEN STOP CLOSE #3 CENTER Stop Button 1 2 3 4 5 SAFETY EXIT 6 #4 DC-BACKUP QCC W4 A B G B A LINK O P E N S MS TOP C L O S E MAGLOCKALARMARMED M/S LINK Install the stop button in a secure accessible place. SYSTEM ON SENSORS TIMER 3 60 POWER OVERLOAD 1 OFF 1 3 1 3 ON 3 OPEN LEFT OPEN RIGHT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR W4 Cut off jumper wire #W4. This is an important command required to stop the audio alarm in case it has been triggered. Otherwise the alarm will sound for 5 minutes and reset itself. Use STOP Button: •To stop the movement of the gate in case of potential entrapment. •To reset the audio alarm, (check for obstructions). •To stop the gate operator while traveling. When using the Omni option board, use the“STOP” input to connect the stop button. S E C O N D A R Y E N T R A P M E N T P R O T E C T I O N Wiring Installation OmniControl Board CENTER SAFETY P EXIT DC-BACKUP W4 G B Edge Sensor A SYSTEM ON MS LINK TIMER SENSORS 3 60 POWER OVERLOAD 1 1 1 3 3 ON OFF 3 OPEN RIGHT OPEN LEFT FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR Mounting Installation Drill 1/2" Hole if necessary to Feed Wire Through 2 Wires to Gate Operator Omni Control Board Use #10 Screws as Necessary to Mount Edge Black Mounting Tab All of the installed edge sensors are connected in parallel at the sensor input terminals on the Omni control board. Top View of Gate Operation Recommended Installation Locations Recommended Edge Sensor Locations Wall Wall Gate Edge Sensor Recommended Location Install edge sensors appropriately at recommended locations to insure sufficient entrapment protection for your installation to prevent injury. SL Operator Edge Sensor Recommended Location If you are going to use a contact sensor as a secondary entrapment protection you should use a recognized component to comply with the revised UL 325 for use in class I or class II gate operator. Electric Sensing Edge, Miller Edge Models: MGR20 or MGS20 T R O U B L E S H O O T I N G L E D I N F O R M A T I O N Resetting Motor Reset Motor LED Light is “ON” Motor Reset Button Press firmly to reset thermal breaker on the motor. Gate Will Not Close! Gate Will Not Open! Symptom: The radio receiver LED on the control Symptom: The radio receiver LED on the control board remains “ON” when using the remote control. board remains “OFF” when using the remote control. Possible Solutions: Stuck remote control Possible Solutions: Dead battery in the remote button. The radio receiver has malfunctioned in the “ON” position. control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the “OFF” position. T R O U B L E S H O O T I N G CONDITION POSSIBLE CAUSES T A B L E SOLUTIONS OVERLOAD LED ON And POWER LED OFF 1.Short circuit at terminals 8 and 10 2.Short circuit at any of the loop detectors in the board 3.Short circuit in the control board OVERLOAD LED ON And POWER LED ON 1.Excessive current draw at terminal 10 1.Reduce the accessories load from 2.Over-voltage at the 120 VAC line input terminal 10 2.Verify your electrical power SYSTEM ON LED FLASHING 1.One limit switch is faulty 2.Motor thermal fuse has poped-out 1.Remove the short circuit condition at the terminals 2.Remove the defective loop detector 3.Send the board to repair 1.Test the limit switches and wire connections, fix the fault 2.Reset the motor REVERSE SENSOR LED 1.Gate has encountered and obstruction 1.Remove the obstruction during traveling 2.Turn the reverse sensor switch counter ON 2.Reverse sensor is extra sensitive clockwise a little more and try again ALARM SENSOR LED ON 1.Gate encountered an obstruction during traveling 2.Alarm sensor is extra sensitive 1.Remove the obstruction 2.Turn the alarm sensor switch counter clockwise a little more and try again ALARM SENSOR LED ON 1.Gate encountered and obstruction during traveling 2.Alarm sensor is extra sensitive 1.Remove the obstruction 2.Turn the alarm sensor switch counter clockwise a little more and try again COMMAND PROCESSED 1.There is a command hold active LED ON TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING 1.There is a command holding the gate open TIMER LED BLINKING, 1.Gate has reopened because it COMMAND PROCESSED encountered an obstruction while LED BLINKING And closing. REVERSE SENSOR LED ON AUDIO ALARM ON ANY “LOOP LED” ON And NO VEHICLE ON THE SENSING AREA 1.This is a normal response of the gate operator. It does not represent necessarily that there is a problem. 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. Check inputs for command. 1.Any re-new command will resume normal operation. Check for obstructions. 1.Gate has encountered two 1.Any re-new command will resume normal consecutive obstructions while trying operation but not a radio command. Check for to close or open obstructions. 2.You can stop the alarm by using the stop button. 1.The loop detector needs to be reset. 2.The wire loop has been disrupted 3.The loop detector needs to work in a different frequency 4.The loop detector is too sensitive 1.Reset the loop detector (If you use Elite Plug-in Loop detectors, change the setting for sensitivity and come back to your original setting). 2.Verify and correct connections 3.Set a different working frequency 4.Decrease the sensitivity of the loop detector S L - 3 0 0 0 P A R T S Limit Switch Assembly Power Back-Up SL Q010 Q164 *Q029 SL DM *Q032 Q065 O-DC Q031 Q123 Q051 *Q101 Q209 Q033 Q143 O-DC-SL O-DC-SL DM Q023 Q024 Q177 Q254 Electronic Box Assembly Q030 Q421 Q028 Q039 Q237 Q025 Q020 Q027 Q420 Q021 Q112 Q402 1/2 HP Q403 1 HP Q014 Q018 Q016 Q408 Q015 A H-110 #41 *Q013 Q404 Q401 Q400 A H-113 A H-111 #40 A ELD A H-125 Q006 O-OMNI EXB Q005 *Q003 *Q004 Q009 O-QCC OMNI Note: *Sold Individually, 2 Shown. For part names, refer to parts list S L - 3 0 0 0 P A R T S L I S T AH-110 - Gate Chain No.41 (10 ft) A H-111 - Gate Chain No.40 (10 ft) A H-113 - Master Link, Nickel Plated A H-125 - Master Link Limit Switch Assembly Q003 - Chain Bolt Q010 - Limited Switch Box Cover Q004 - Chain Bracket Q023 - Limit Switch Box Q005 - SL-3000 Chassis Q006 - PC Board Nuts (1 Set) Q024 Q031 - Limit Switch / Shaft Q032 - Limit Switch Adjustment Nuts Q009 - Electronic Access Panel Q014 - Drive Sprocket Q051 - Limit Switch / Shaft Bearing Q015 - Gear Reducer Q101 - Limit Switch Bearing Holder Q016 - Limited Switch Drive Sprocket Q018 - 1/2 HP Electric Motor Power Back-Up Unit Q020 - Drive Belt Q065 - Drive Belt (DM) Q021 - Gear Pulley Q123 - Back-Up Motor DC 12V Q025 - Motor Pulley Q143 - Chassis DC Back-Up O-DC-SL Q027 - Motor Capacitor O-DC-SL DM Q164 - Drive Belt Q028 - Manual Crank Q177 - Wire Harness DC-1000 Q029 - Limit Switch Q209 - Pulley DC-1000 1/2 ID Q030 - Limit Switch / Chain Q033 - Limit Switch Sprocket Q039 - Drive Belt, DM and 1 HP Electronic Box Assembly Q112 - Wire Harness-B Terminal Block Q402 1/2 HP Q403 1 HP Q237 - Crank Input Q254 - Cover HD Polyethylene Flexible Assembly for 1/2 Horse Motor Q400 - OMNI Main PCB Q420 Wire Harness and Conduit Q401 - OMNI 1 Horsepower Board # Q404 - OMNI Alarm Flexible Assembly for Dual Motor Q408 - Electronic Power Strip Q421 Wire Harness and Conduit A ELD - Loop Detector # Muliple Parts “Q” Numbers O-OMNI EXB - OMNI Option Board# #OmniControl Board Accessories O-QCC OMNI - QCC Access ID# Idler Sprocket Assembly Q013 M A I N T E N A N C E 1. 2. 3. 4. 5. 6. Make sure the reversing sensor is functioning properly. Refer to “Reverse Sensor”. Make sure the gate track is clear of dirt, rocks or other substances. Make sure the wheels are operating smoothly on the track. If you hear an Alarm, Refer to “Audio Alarm”. Clean the cover on a regular basis. For part illustrations, Refer to “SL-3000 Parts”. If you need further assistance, please contact your local service company. External “Safety” Loop Detectors Remote Control System Three Push Button Key Switch Card Reader Photo Electric Eye Outdoor Digital Lock Outdoor Digital Lock with Intercom Key Station Indoor Intercom Speaker Outdoor Intercom Speaker