DEPAC DEPAC Auto-Dynamic Load (ADL) Control System:
Transcription
DEPAC DEPAC Auto-Dynamic Load (ADL) Control System:
DEPAC 201 Mill St. Rome, NY 13440 (315) 339-1265 www.depac.com Dyno Systems Setting The engine testing Standards for this century DEPAC Auto-Dynamic Load (ADL) Control System: INSTALLATION Diagrams: DEPAC Load Control System for Stuska® 800 Dyno. 1. 2. 3. 4. 5. 6. 7. 8. Complete Kit of parts and Instructions are included to ensure a proper installation. Refer to the Diagrams for proper layout. Best to have pump and water tank close. Use 1 ½ “ (or greater) pipe size water lines. Best to use Rubber Hose, 150 PSI. For pumps less than 15 feet from the dyno use 1 ½” EDPM Rubber Hose in place of any solid PVC or Copper lines with elbows. Use 10 Gallon Diaphragm Accumulator as shown for water lines up to to 50 feet. Use Two 10 Gallon Accumulators for Solid lines out to 100 feet. 3 units for more. Always use 2’ EDPM hose and fitting (with PSI gauge) included for the Control Valve. Replace the Stuska Restrictors with the DEPAC outlet manifold and Refer to the Table to Set the single outlet Gate Valve. (Example: 4 quarter turns open for 600 BHP.) Important that each rotor hold the same amount of water for proper operation. Diaphragm Accumulator, 10 Gal, is from Granger 4UP01 (Amtrol ST-25V or Equivalent) EPDM Rubber hose 1 1/2”, rated 150 PSI, is from McMaster 5304K47, by the foot. DEPAC Dyno Systems 201 Mill St. Rome, NY 13440 (315) 339-1265 www.depac.com Pre-Charge Air to 70% of Working Water Pressure. 1" Hose 10 GAL Expansion Tank ACCUMULATOR ADL Inlet Valve When Feeding water from the SIDE 1.5" Rubber Hose PSI 0 Floor Bypass DRAIN 100 90 10 80 20 70 30 40 50 60 Fixed Mount to Frame Go Power or DTS Dyno Pre-Charge Air to 70% of Working Water Pressure. 10 GAL Expansion Tank 1" Hose ACCUMULATOR 1.5" Rubber Hose Do this ONLY when Plumbing Water from the REAR of the Dyno PSI 0 100 90 10 80 20 70 30 40 50 60 Bypass DRAIN Floor ADL Inlet Valve (FULL Load) 1 2 O (ALT) T S T S O O O O LOAD 60 O 50 % 201 Mill St. Rome, NY 13440 (315) 339-1265 40 70 O 30 (Max RATE) Auto-Dynamic Load Control 10 100 % MAX OPEN LOAD 0% Speed-Hold O RATE 6 7 4 8 2 10 www.depac.com Valve MODE AUTO STOP DWN 4 RPM 11 6 7 3 UP HOLD Load MORE 1 STABLE Not Stable LESS Load 9 3 Manual 90 5 SN DIRECT 20 80 SET SET % LOAD RPM DEPAC Warm-up Mode 4 O 8 2 9 1 0 RATE 10 (FULL Load) 1 2 O (ALT) T S T S O O O O LOAD 60 O 50 % 201 Mill St. Rome, NY 13440 (315) 339-1265 40 70 O 30 (Max RATE) Auto-Dynamic Load Control 10 100 % MAX OPEN LOAD 0% Speed-Hold O RATE 6 7 4 8 2 10 www.depac.com Valve MODE AUTO UP STOP HOLD Load MORE 1 STABLE Not Stable LESS Load 9 3 Manual 90 5 SN DIRECT 20 80 SET SET % LOAD RPM DEPAC Warm-up Mode 4 O DWN 4 RPM 11 6 3 7 1 9 8 2 0 RATE 10