Darling New # DN 7536

Transcription

Darling New # DN 7536
Leben im Bad
Living bathrooms
Darling New
# DN 7536
38
74
B
74
38
170
110
Installation instructions
90
A
90
2050
1940
90
A
mm
B
mm
800
576
2x 100
4x S8
4x 5,5x50
Instructions for use
The bathroom furniture range complies with the standards and guidelines applicable at the time of delivery and is designed for use in bathrooms.
Direct contact with water should be avoided, for example, when showering.
A power supply of 110 V – 230 V must be available on site.
Distance from the sensor to the reflecting surfaces = > 75 mm.
We reserve the right to make technical improvements and design modifications to the products illustrated.
MAL_Darling New_DN7536/14.03.1
1
2
3
4
2
Ø 8 mm
1
230 V
4x
5
6
7
8
9
10
11
12
1
2
8x
4x
14
15
16
17
18
19
20
Best.-Nr. DN7536/14.03.1
13
Duravit AG, Werderstr. 36, 78132 Hornberg, Germany, Phone +49 78 33 700, Fax +49 78 33 70 289, [email protected], www.duravit.de
MAL_Darling New_DN7536/14.03.1
Leben im Bad
Living bathrooms
Mounting instructions
for bathroom furniture with a power supply
Safety
2
Electrical installation
3
Mounting
4
Safety
Intended use
Safety instructions
The mounting instructions come as part of the Duravit
product and are aimed at people who carry out the
electrical installation for the product. You must read
through the mounting instructions carefully and they must
be available at all times.
Danger to life
Contact with electricity may lead to an electric shock.
>> Carry out the electrical installation in accordance with
the national, European and international directives and
standards.
>> Observe protection zones for wet rooms in accordance
with country-specific standards, local regulations and
low voltage guidelines.
>> Connect the electrics using a ground fault circuit
interrupter (GFCI) in wet rooms or other specially
equipped rooms.
>> Disconnect electrical components from the power supply
before the installation.
>> Check that all components are de-energised.
>> Prevent the power supply from being switched on
accidentally.
Target readership and qualifications
The electrical installation may only be carried out by
qualified electricians.
Protection rating of Duravit products
The protection rating of Duravit products with a power
supply complies with the IP 44 standard as a minimum.
Protection class of wall lights
Protection class Connecting cable
I
H05VV-F, 3x 1.5 mm
II
H03VV-F, 2x 0.75 mm2
2
Standards and directives
Duravit products comply with the CE marking
directives:
Penetration of foreign bodies and water
Foreign bodies or water in equipment lead to a short circuit
that may cause damage to the product.
>> Observe the protection zones for Duravit products.
Protection zones
0
60
A
0
60
1
Icons and symbols
B
Meaning
This symbol highlights useful and important
information.
s
Seconds
>
Action required
2250
Symbol
2
0
A A mirror cabinet with an IP 44 rating may protrude into zone 2.
B A socket in a mirror cabinet must be mounted outside the zones.
2 MAL_51240/16.03.1
Electrical installation
Electrical installation for protection class I
Electrical connection
L
N
Optional connection of an external button
L
N
L'
Electrical installation for protection class II
Electrical connection
L
N
L
N
Optional connection of an external button
L
N
L'
MAL_51240/16.03.1 3
Mounting
Duravit AG · P.O. Box 240 · Werderstr. 36, 78132 Hornberg, Germany · Phone +49 7833 70 0 · Fax +49 7833 70 289 · [email protected] · www.duravit.com
Measuring mode
The control unit has a measuring mode. Once the
measuring mode is active, the light is switched on again
automatically 90 seconds after it has been switched off.
The measuring mode may be triggered during an
installation under voltage by accidentally actuating
the touch LED/infrared switch continuously.
>65 s
The light flashes 6 times.
>> Actuate the touch LED/infrared switch again for more
than 65 seconds to deactivate the measuring mode. Use
a reflective object (paper) for the infrared switch.
The light flashes 4 times.
4 MAL_51240/16.03.1
Order no. 51240/16.03.1 We reserve the right to make technical improvements and enhance the appearance of the products shown
>> Actuate the touch LED/infrared switch for longer than
65 seconds to activate the measuring mode. Use a
reflective object (paper) for the infrared switch.