Liebert TVSS: The First Line of Defense

Transcription

Liebert TVSS: The First Line of Defense
Liebert TVSS: The First
Line of Defense Product Overview
Jim Tiesi
INTERCEPTOR
SURGE SUPPRESSION
Overall Design
True modular design
Low impedance copper
conduction plates
Best in class performance
Real-time status
Built-in test capability
Stringent third party testing
Warranty: 10 year
January 21, 2005
Board Meeting
3
Company Confidential
Enclosure
NEMA 4 w/status mounted
behind protected window
Black, textured paint, silkscreened
Status label includes
pushbutton to operate
Audible, Push to Test, BIT,
and Counter Reset
January 21, 2005
Board Meeting
4
Company Confidential
Copper Interior
Low impedance copper
conduction plates
Copper back plane
Maximizes surface area
High mechanical strength
Heavy duty tin plated copper lugs
Conductor sizes to # 1/0AWG
January 21, 2005
Board Meeting
5
Company Confidential
Rotary Disconnect (Fused)
Lock off-able safety feature
Extremely low impedance
Heavy duty industrial quality
Tin plated copper lugs and
conductor surfaces
True “through door” disconnect
for NEMA 4 rating
January 21, 2005
Board Meeting
6
Company Confidential
Capacitors
30 microfarad total capacitance;
highest in industry
Great ring-wave attenuation
EMI / RFI filtering
–100kHz: 41 dB
–10MHz: 35 dB
–1 MHz: 31 dB
–100MHz: 53 dB
January 21, 2005
Board Meeting
7
Company Confidential
Surge Module
MOV
Custom, Durez coated, 25 mm MOVs
– MOV surge capability 18 kA
Array of 7 MOVs per module matched
to +/- 1 volt
Fusing
Component level, coordinated fusing
99.9% pure, silver link fuse
200 kAIC rating
individual fuse links w/ monitoring on
all modes
January 21, 2005
Board Meeting
8
Company Confidential
Protection Redundancy
Industry Typical
Phase
Conductor
WEAK
Fuse Link
30 kA
18 kA 18 18 18 18 18 18 kA
No Weak Links
MOV
18 18 18 18 18 18 18 kA
Reality 30 kA
18 18 18 18 18 18 18 kA
125 kA Reality
NEUTRAL / GROUND
January 21, 2005
Board Meeting
9
Company Confidential
Surge Module
Surge Ratings
80 kA, 100 kA, and 125 kA modules
Independent surge current testing by R&B
Labs
Flexible per phase kA ratings from 160 kA
to 1000 kA
Endurance testing / 15,000 category C3
impulses < 1.5% degradation
Approved for direct bus connections
January 21, 2005
Board Meeting
10
Company Confidential
Unit Status
Internal and external LEDs
Audible alarm
Form C contacts
Built-in-Test feature
Self check logic buss
Tests each fuse/MOV in every
module L-N, L-G, N-G
% protection per phase
Undervoltage detection
Phase loss monitoring
January 21, 2005
Board Meeting
11
Company Confidential
NEMA LS 1 Test Package
High current abnormal over-voltage test (AIC Rating)
Maximum continuous operating voltage (MCOV)
Surge current test
UL 1449 suppressed voltage rating (SVR)
Frequency response curve
UL 1449 authorization
Endurance testing
January 21, 2005
Board Meeting
12
Company Confidential
Liebert Interceptor II Series Model
Number
SIxxxyyyYARSE
Surge Rating
016 (160kA)
025 (250kA)
032 (320kA)
040 (400kA)
050 (500kA)
060 (600kA)
075 (750kA)
100 (1000kA)
January 21, 2005
Board Meeting
Enclosure Options
E = NEMA 4(Std)
N = Caseless
Monitoring Options
Source
Voltage
S = Std
Configuration
120
C = 1 Counter
208 N = Single Phase L-N
D = Dual Counter
Connection Options
220 L = Single Phase L-L
R = With Disconnect
230 S = Split Phase
N = Wire Lug
D = 3-Phase Delta
240
Y = 3-Phase Wye
Protection
277
H = 3-Ph Delta Hi-leg Modes
480
A = All
13
Company Confidential
Summary: Liebert Interceptor II Series
Ideal protection for service entrance and
distribution
UL 1449, UL 1283, CE, and CUL
UL rated 200kAIC fuse network
160 kA to 1,000 kA /Phase surge
capacity
Independent Test Pkg. Nema LS1
Unmatched levels of redundancy
January 21, 2005
Board Meeting
14
Company Confidential
Liebert AccuVar Series
Protection for service
entrances less than 1200
amperes and distribution
panels
UL 1449, UL 1283, OWHX and CUL Listed
ACV models offer 65 kA per mode/ 130kA/
phase surge current capacity
ACVII models offer 80 kA per mode/ 160kA/
phase surge current capacity
UL Rated 200 kAIC fuse network
NEMA LS 1
January 21, 2005
Board Meeting
15
Company Confidential
Liebert AccuVar Series
Life cycle rating Category C3 Impulses
ACV 6,000 per mode/12,000/ phase
ACVII 8,000 per mode/16,000/ phase
Compact module design - easily retrofits
on panelboards
Flush mount kit
On-line monitoring in all modes
EMI/RFI filtering option
Any modes of protection available
Enclosure NEMA 4X
Warranty: 10 year
January 21, 2005
Board Meeting
16
Company Confidential
Liebert AccuVar Series Model Number
ACVxxxY101RKE
Note:
New Ratings
ACV = 65 kA Modules
ACVII = 80 kA Modules
Voltage
120
240
277
208
480
January 21, 2005
Board Meeting
Source
Configuration
N = Single Phase
S = Split Phase
D = 3-Phase Delta
Y = 3-Phase Wye
17
Company Confidential
Options
R = Red/Green LED
K = Form C Contact
E = EMI Filter
Surge Protection Modes
1xx = L-L or L-N
x1x = L-G
xx1 = N-G
And Number of Modules
e.g. 201
Liebert Interceptor Hybrid Advantage
Designed specifically for the needs
of the telecommunications
industry
True hybrid - integrates response time of SAD’s
with the high-energy capability of the
Interceptor MOV design
Industry’s only Active Disconnect System Surge
Surge current ratings from 50 kA to 750 kA per
phase
January 21, 2005
Board Meeting
18
Company Confidential
Interceptor Hybrid Advantage
Source
Load
Electronic
Electronic
Disconnect
Disconnect
Current
CurrentDiverter
Diverter
Module
Module
Current
CurrentDiverter
Diverter
Module
Module
SAD
SAD
Control
Control
Circuit
Circuit
Impedance
Impedance
Current
CurrentDiverter
Diverter
Module
Module
Ground
January 21, 2005
Board Meeting
Neutral
19
Company Confidential
MOV & SAD CLAMPING CHARACTERISTICS
MOV & SAD Clamping Characteristics
Clamping Voltage (Volts)
600.0
MOV
500.0
400.0
SAD
300.0
200.0
100.0
0.0
0
2500
5000
Surge Current (Amperes)
January 21, 2005
Board Meeting
20
Company Confidential
7500
10000
Interceptor Hybrid Advantage
Percentage of Surge Current (%)
SAD Hybrid Interceptor Surge Current Sharing Data
H2120Y222R-01
Hybrid SAD Module
100.0
Interceptor MOV Module
90.0
80.0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0
5000
10000
15000
20000
25000
Total Surge Current (Amperes)
January 21, 2005
Board Meeting
21
Company Confidential
30000
Interceptor Hybrid Advantage
All components are computer tested and
matched
SAD’s within ± 1%, MOVs within 1 volt
Matched low impedance buss system for
SAD and MOV modules
Primary stage joule ratings:
“H1” modules
250 joules
“H2” modules
500 joules
UL rated 200 kAIC fuse network
Options audible alarm, transient counters,
test set, NEMA 3R, 4, 4X enclosures
Warranty: 10 Year
January 21, 2005
Board Meeting
22
Company Confidential
Interceptor Hybrid Advantage Model
Number
H1xxxY111R
R = With Disconnect
H1 = 250 Joule SAD
H2 = 500 Joule SAD
Voltage
120
240
277
208
480
January 21, 2005
Board Meeting
Source
Configuration
S = Split Phase
D = 3-Phase Delta
Y = 3-Phase Wye
23
Company Confidential
Surge Current Ratings
111 Series 250kA/Phase
222 Series 320kA/Phase
333 Series 400kA/Phase
444 Series 750kA/Phase
Motorola R56 Version
Interceptor & Hybrid Advantage
Motorola R56 Standards & Guidelines for Communication Sites
Competition
Transtector
A-C Data
Northern Tech
January 21, 2005
Board Meeting
24
Company Confidential
Motorola
Interceptor Hybrid Advantage Type 1 & 1A
Source
Load
MOV
MOV
Current
CurrentDiverter
Diverter
Module
Module
Normal Mode (L-N, L-L)
January 21, 2005
Board Meeting
SAD
SAD
Impedance
Impedance
Neutral
25
Company Confidential
Motorola R56 Version Hybrid Advantage
Type 1A
– Protection for facilities located
where the level of exposure is high
Primary SAD module: 500 J / phase
Secondary MOV module: 5000 J / phase
L-N suppression only
330 volt protection level
Pulse life requirements
(40) 20 kV / 10 kA
(360) 6 kV / 3 kA
NEMA 4X
Warranty: 10 Year
January 21, 2005
Board Meeting
26
Company Confidential
Motorola R56 Version Interceptor
Type 2
– Protection for specific applications
MOV modules: 5000 J / phase
L-N suppression only
400 volt protection level
6 kV / 3 kA per UL 1449 Edition 2
Pulse life requirements
(400) 6 kV / 3 kA
NEMA 4X
Warranty: 10 Year
January 21, 2005
Board Meeting
27
Company Confidential
Liebert AccuGuide
Transmits transients generated by
lightning and switching
Minimal voltage drops
Patented coaxial cables
Minimizes inductance through a reduced
coaxial aspect ratio
Extremely low impedance (2-10 Ω)
Losses are under 4.2 V / ft / kA
Especially valuable in cases where SPD
cannot be installed close to the point of
protection (> 5 ft)
January 21, 2005
Board Meeting
28
Company Confidential
AccuGuide Coax Construction
l
l
l
Conventional conductor voltage losses
exceed 16V/ft/kA
AccuGuide coax voltage losses are less than
4.2V/ft/kA
AccuGuide provides 400% improved
performance
Jacket
Outer Braid
Inner Braid
Conductor
Primary & Secondary
Insulation
January 21, 2005
Board Meeting
29
Company Confidential
AccuGuide 3kA Performance
#10 AWG
AccuGuide
Clamping Voltage
3500
3000
2500
2000
1500
1000
500
0
0
7.5
16.5
26
Distance Feet
January 21, 2005
Board Meeting
30
Company Confidential
33
43
Liebert LM Series®
Service entrances and
distribution panel applications
“Competitive Grade” product for
competitor controlled specifications
Modular design
120 kA to 500 kA per phase surge
current capacity
UL rated 200kAIC fuse network
All modes of protection
Internal and external LEDs, Form C
Contacts, & Audible Alarm
January 21, 2005
Board Meeting
31
Company Confidential
Liebert LM Series®
EMI / RFI filtering
Complete Testing/Certifications:
UL 1449, UL 1283, and CSA Listed
NEMA LS1 (up to LM200)
5 year parts warranty
Options: disconnect, counter, test set,
enclosures - NEMA 3r, 4 & 4X
January 21, 2005
Board Meeting
32
Company Confidential
Model # designation - LM Series
LM 1 - 2 - 3 - 4 - 5- 6 - 7
Ex: LM080120YARSE
1
Surge Level per Mode : 060, 080, 100, 125, 150, 200, 225,
250, 300
2
Voltage: 120, 208, 220, 230, 240, 277, 347, 480, 600
3
Phase Configuration: N (1 ph L-N), L (1 ph L-L), S (split), Y
(Wye), D (Delta), H (Delta Hi-Leg), X (Wye no neutral)
4
Modes of Protection: A (All)
5
Disconnect: N (no disconnect), R (disconnect)
6
Options: S (standard: LEDs, form C, AA), C (Counter)
7
Enclosure: E (standard 12), R (3R), T (4), X (4X)
January 21, 2005
Board Meeting
33
Company Confidential
Liebert PowerSure Medium Exposure
Non modular TVSS
Ideal for 800 Amp panels or less
Surge Current Ratings: 100kA, 160kA
Fault tested to 65 kAIC
Dimensions:
100kA - 6.0”x4.0”x3.0” ,
160kA-8.0”x6.0”x4.0”
EMI/RFI Noise Attenuation
Status Indication: LED, Form C
Certifications: UL 1449, CUL
Warranty:
January 21, 2005
Board Meeting
34
Company Confidential
5 Years
Model # designation - PowerSure Medium
Exposure
LPM - 1 - 2 - 3
EX: LPM277Y160
1 - Voltage: 120, 208, 240, 277, 480
2 - Phase Configuration: N (1 ph L-N), L (1 ph L-L), S (split),
Y (Wye), D (Delta), H (Delta Hi-Leg), X (Wye no neutral)
3 - Surge Capacity:
160 (160 kA per ph/ 80 kA per mode)
100-2 (100 kA L-N, N-G)
January 21, 2005
Board Meeting
35
Company Confidential
Liebert PowerSure Low Exposure
Non modular TVSS
Ideal for 400 Amp panels or less
Surge Current Ratings: 25kA, 50kA, 100kA
Fault Tested to 14 kAIC
Dimensions:
4.72”x4.72”x2.36”
EMI/RFI Noise Attenuation
Status Indication: LED, Form C Contacts
Certifications: UL 1449, CUL
Warranty:
January 21, 2005
Board Meeting
5 Years
36
Company Confidential
Model # designation - PowerSure Low
Exposure
LPL - 1 - 2 - 3
Ex: LPL120S25-2
1 - Voltage: 120, 208, 240, 277, 480
2 - Phase Configuration: N (1 ph L-N), L (1 ph L-L), S (split),
Y (Wye), D (Delta), H (Delta Hi-Leg), X (Wye no neutral)
3 - Surge Capacity:
100 (100 kA per ph/ 50 kA per mode)
50 (50 kA per ph/25 kA per mode)
25-2 (25 kA L-N, N-G)
January 21, 2005
Board Meeting
37
Company Confidential
Why LIEBERT TVSS?
l
MOV / SAD Matching - Every MOV / SAD is voltage matched to
allow complete current sharing
l
Component Level Fusing - Every MOV/SAD is individually fused
and monitored
l
200 kAIC Silver Fuse Network - Allows rated surge current to
pass without fuse operation
l
NEMA LS 1 complete documentation package
l
Modular and non-modular devices/power, data, and telecom
l
Broadest range of ratings 25 kA to 1000 kA
January 21, 2005
Board Meeting
38
Company Confidential