Surge Protection Devices - GE Industrial Solutions
Transcription
Surge Protection Devices - GE Industrial Solutions
Surge Protection Devices (SPD) Section 5 Critical Power Products Introduction ....................................................................................................5-2 Integrated Tranquell™ ME (to connect with GE “A”Series Panelboards).....................................................................5-3 Integrated Tranquell™ HE and ME (for GE Distribution Equipment) ..........................................................5-5 Tranquell™ 9X and 24X (Box Extensions for GE “A” Series Distribution Equipment) .............................................5-8 Tranquell™ HE and ME (Wall Mount) ....................................................5-12 Tranquell™ ME and LE (Wall Mount) .....................................................5-18 Tranquell™ DIN Rail Mount .......................................................................5-20 Protection Block Assembly ......................................................................5-22 Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 5-1 Surge Protection Device (SPD) Section 5 Critical Power Products Introduction General Electric has been a leader in lightning and surge protection for commercial, industrial and utility applications for decades. The GE Surge Protection Device product line utilizes the combined strengths of GE engineering capabilities and surge suppression technology. GE SPD products use quality materials and innovative designs to achieve the best possible performance while maintaining competitive prices. All units are 3rd party tested to the NEMA LS-1 standards, are rated in accordance with NEC Article 285 and comply with UL1449, 3rd Edition. We have a full line of SPD products available, integral to GE Distribution Equipment, or wall mounted. GE has a strong commitment to customer service. We offer a level of service and engineering support unmatched by our competition. Many of our products are designed to suit specific customer applications. Our application engineering team is ready to provide solutions for your surge suppression needs. Contact your local GE sales office for additional information. References Integrated SPD Wall Mounted DEA-390, DEA-391, DEA-393, DEA-394 DEA-300, DEA-320, DEA-391, DEA-392 5-2 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Integrated Tranquell™ ME Designed to Connect within GE “A Series™” Panelboards This SPD model connects directly to the A Series™ Panelboard bus bars without adding width or depth to the panel enclosure. These devices have been tested to surge current ratings per NEMA LS-1, including the fuses in the surge path. Since these surge protection units are mounted to the bus bars, a breaker feeder is not required or used. This design allows for maximum protection. Ratings are available from 65kA per mode to 100kA per mode. All mode protection is provided with surge components (MOVs) connected on the phase to neutral, phase to ground, and neutral to ground paths as appropriate for the voltage configuration. Integrated Tranquell™ ME products are engineered for reliability, flexibility and long life in the most extreme surge environment. The true maximum surge current rating, unlimited by fusing, has been proven successful in 3rd party tests. Features and Benefits Specifications —UL1449, 3rd Edition CUL —Optional UL1283 Noise Filters —UL Tested to 65,000 Amperes Symmetrical Withstand —Tranquell™ ME Device is Capable of Surviving a minimum of 5,000 Category C3 Impulses (10kA, 20kV) per mode —Form C Dry Contacts for Remote Monitoring —Green Status Indicating Lights, Red Service Light —Audible Alarm with Test/Disable Feature —Standard Surge Counter on AS —Factory installed in GE "A Series™" Panels —Standard 5 year limited warranty, Optional 20 year warranty Operating Frequency: Connection: Operating Temperature: Operating Humidity: Weight: 50/60 Hz Direct Bus Connection, Parallel Connected -40°C to +65°C 0% to 95% Non-Condensing 13 lbs. 1.331 [33.81] 0.312 [7.91] TYP 5.064 [128.62] 0.236 [ 5.99] HOLE (4 PLACES) 6.000 [152.40] 5.331 [135.41] 8.321 [211.36] 9.494 [241.15] 2.869 [72.87] 9.400 [238.76] Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 5-3 Surge Protection Device (SPD) Section 5 Critical Power Products Integrated Tranquell™ ME Designed to Connect within GE "A Series™" Panelboards For GE "A" Series Panelboards - 65 kA Symmetrical Fault Withstand Panelboard, Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current Product Number 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase TPME120S06AS TPME120Y06AS TPME220Y06AS TPME277Y06AS TPME480D06AS TPME347Y06AS TPME240H06AS TPME240D06AS TPME240Y06AS TME600D065AS TPME120S08AS TPME120Y08AS TPME220Y08AS TPME277Y08AS TPME480D08AS TPME347Y08AS TPME240H08AS TPME240D08AS TPME240Y08AS TME600D080AS TPME120S10AS TPME120Y10AS TPME220Y10AS TPME277Y10AS TPME480D10AS TPME347Y10AS TPME240H10AS TPME240D10AS TPME240Y10AS TME600D100AS Product # T P * M E * AS = Full featured, with UL 1283 noise filtering and surge counter ASNF = without UL 1283 noise filtering (Available 100kA per Mode) only ASNC = without UL 1283 noise filtering, without surge counter (Available 100kA per Mode) only Voltage Protection Rating (VPR) UL 1449, 3rd Edition September 2009 Revision Nominal System Voltage Voltage (Volts RMS) Configuration 120S HL-G 06 65kA 130kA — 600 — 600 1200 125% 08 80kA 160kA 600 1200 125% 10 100kA 200kA 700 120Y 120Y/208 3 Ph, 4 W + G 700 — 600 — 240 Delta 3 Ph, 3 W — — 900 — 240H 120/240 Delta HL 240Y 1800 115% 3 Ph, 4 W + G 700 1200 600 1000 600 1200 115% 240Y/415 3 Ph, 4 W + G 1200 — 1000 — 1000 2000 130% 277Y 277Y/480 3 Ph, 4 W + G 1200 — 1000 — 1000 2000 115% 220Y 220Y/380 3 Ph, 4 W + G 1200 — 1000 — 1000 2000 145% 347Y 347Y/600 3 Ph, 4 W + G 1500 — 1500 — 1500 3000 115% 480D 480 Delta 3 Ph, 3 W — — 1500 — — — 3000 170% Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637 1738. BuyLog™ Catalog Per Phase L-G 240D 5-4 Per Mode HL-N 1 Ph, 3 W + G L-L Maximum Surge Current Capacity L-N 120/240 N-G MCOV % Max. Continuous Operating Voltage www.geindustrial.com Phase Rating = (L-N + L-G) Product # Example TPME277Y10AS —277Y/480 V, 3 Ph, 4 W + G —100kA per mode —Full featured, with UL 1283 noise filtering and surge counter Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Integrated Tranquell™ HE and ME Designed for GE Distribution Equipment This SPD model connects to the panelboard or switchboard bus bars without adding width or depth to the panel enclosure, and only occupying 7X of vertical bus space. These units have been tested to surge current ratings per NEMA LS-1, up to 200 kA per mode, including the fuses in the surge path. Standard features include a surge counter, audible alarm, indicating lights, dry contacts, and an integral surge rated disconnect. Rating options range from 65 kA per mode to 300 kA per mode. All mode protection is provided with surge components (MOVs) connected on the phase to neutral, phase to ground, and neutral to ground paths as appropriate for the voltage configuration. Integrated Tranquell™ HE and ME products are engineered for reliability, flexibility and long life in the most extreme surge environment. The true maximum surge current rating, unlimited by fusing, has been proven successful in 3rd party tests. Features and Benefits Specifications —UL1449, 3rd Edition CUL, UL1283 —UL Tested to 200,000 Amperes Symmetrical Withstand —Integral Surge Rated Disconnect —Factory installed in Spectra™ Series Panels and Switchboards (7X Mounting Space), or Switchgear —Tranquell™ ME Device is Capable of Surviving a minimum of 5,000 Category C3 Impulses (10kA, 20kV) per mode. —Tranquell™ HE Device is Capable of Surviving a minimum of 20,000 Category C3 Impulses (10kA, 20kV) per mode. —Device Capable of Surviving a minimum of 5,000 Longwave (10x1000ms) Impulses per mode. —Enhanced Thermal Protection Technology —Form C Dry Contacts for Remote Monitoring —Green Status Indicating Lights, Red Service Light —Audible Alarm with Test/Disable Feature —Standard Surge Counter —Standard 5 year limited warranty, Optional 20 year warranty Operating Frequency: Connection: Operating Temperature: Operating Humidity: Weight: 17.722 [450.130] 0.340 [8.636] 17.382 [441.494] 50/60 Hz 6 to 2/0 Conductors, Parallel Connected -40°C to +65°C 0% to 95% Non-Condensing 24 lbs. [ 0.280 7.112] HOLE (4 PLACES) 6.964 [176.877] 9.400 [238.755] 6.762 [171.751] TYP 7.202 [182.922] 2.638 [67.004] TYP Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 5-5 Surge Protection Device (SPD) Section 5 Critical Power Products Integrated Tranquell™ HE and ME Designed for GE Distribution Equipment For GE MCC Distribution Equipment For GE Spectra™ Panel or Switch Board Distribution Equipment - 200 kA Symmetrical Fault Withstand Panelboard, Lights, Alarm, Surge Counter, Form C Contacts 200 kA Symmetrical Fault Withstand Panelboard, Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current Product Number Maximum Surge Current Product Number 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase TPME120S06ME TPME120Y06ME TPME220Y06ME TPME277Y06ME TPME480D06ME TPME347Y06ME TPME240H06ME TPME240D06ME TPME240Y06ME TPME120S08ME TPME120Y08ME TPME220Y08ME TPME277Y08ME TPME480D08ME TPME347Y08ME TPME240H08ME TPME240D08ME TPME240Y08ME TPHE120S10ME TPHE120Y10ME TPHE220Y10ME TPHE277Y10ME TPHE480D10ME TPHE347Y10ME TPHE240H10ME TPHE240D10ME TPHE240Y10ME TPHE120S15ME TPHE120Y15ME TPHE220Y15ME TPHE277Y15ME TPHE480D15ME TPHE347Y15ME TPHE240H15ME TPHE240D15ME TPHE240Y15ME TPHE120S20ME TPHE120Y20ME TPHE220Y20ME TPHE277Y20ME TPHE480D20ME TPHE347Y20ME TPHE240H20ME TPHE240D20ME TPHE240Y20ME TPHE120S30ME TPHE120Y30ME TPHE220Y30ME TPHE277Y30ME TPHE480D30ME TPHE347Y30ME TPHE240H30ME TPHE240D30ME TPHE240Y30ME 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase TPME120S06PP TPME120Y06PP TPME220Y06PP TPME277Y06PP TPME480D06PP TPME347Y06PP TPME240H06PP TPME240D06PP TPME240Y06PP TPME120S08PP TPME120Y08PP TPME220Y08PP TPME277Y08PP TPME480D08PP TPME347Y08PP TPME240H08PP TPME240D08PP TPME240Y08PP TPHE120S10PP TPHE120Y10PP TPHE220Y10PP TPHE277Y10PP TPHE480D10PP TPHE347Y10PP TPHE240H10PP TPHE240D10PP TPHE240Y10PP TPHE120S15PP TPHE120Y15PP TPHE220Y15PP TPHE277Y15PP TPHE480D15PP TPHE347Y15PP TPHE240H15PP TPHE240D15PP TPHE240Y15PP TPHE120S20PP TPHE120Y20PP TPHE220Y20PP TPHE277Y20PP TPHE480D20PP TPHE347Y20PP TPHE240H20PP TPHE240D20PP TPHE240Y20PP TPHE120S30PP TPHE120Y30PP TPHE220Y30PP TPHE277Y30PP TPHE480D30PP TPHE347Y30PP TPHE240H30PP TPHE240D30PP TPHE240Y30PP 5-6 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Integrated Tranquell™ HE and ME Designed for GE Distribution Equipment For GE Switch Gear Distribution Equipment 200 kA Symmetrical Fault Withstand Panelboard, Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase 300kA per mode / 600kA per phase Product Number TPHE120S10SG TPHE120Y10SG TPHE220Y10SG TPHE277Y10SG TPHE480D10SG TPHE347Y10SG TPHE240H10SG TPHE240D10SG TPHE240Y10SG TPHE120S15SG TPHE120Y15SG TPHE220Y15SG TPHE277Y15SG TPHE480D15SG TPHE347Y15SG TPHE240H15SG TPHE240D15SG TPHE240Y15SG TPHE120S20SG TPHE120Y20SG TPHE220Y20SG TPHE277Y20SG TPHE480D20SG TPHE347Y20SG TPHE240H20SG TPHE240D20SG TPHE240Y20SG TPHE120S30SG TPHE120Y30SG TPHE220Y30SG TPHE277Y30SG TPHE480D30SG TPHE347Y30SG TPHE240H30SG TPHE240D30SG TPHE240Y30SG * * Product # Voltage Protection Rating (VPR) UL 1449, 3rd Edition September 2009 Revision System Nominal Voltage Voltage (Volts RMS) Configuration L-N HL-N L-G HL-G N-G L-L PP suffix available for all kA ratings (integral to Spectra™ panel or switchboard) SG suffix for all THE devices (100kA - 300kA) integral to switchgear ME suffix available for all kA ratings (integral to MCC) Maximum Surge Current Capacity MCOV % Max. Continuous Operating Voltage Exposure Level Per Mode Per Phase 06 TPME 65kA 130kA TPHE 120S 120/240 1 Ph, 3 W + G 900 — 800 — 700 1200 125% 08 TPME 80KA 160KA TPME 120Y 120Y/208 3 Ph, 4 W + G 900 — 800 — 700 1200 125% 10 TPME 100kA 200kA 1200 2000 220Y 220Y/380 3 Ph, 4 W + G 1500 — 1200 — 240D 240 Delta 3 Ph, 3 W + G — 1200 — 240H 120/240 Delta HL — 3 Ph, 4 W + G 1000 1200 800 1200 145% 12 TPHE 125kA 250kA 1800 196% 15 TPHE 150kA 300kA 700 2000 115% 20 TPHE 200kA 400kA 25 TPHE 250kA 500kA 30 TPHE 200kA 400kA — 240Y 240Y/415 3 Ph, 4 W + G 1500 — 1200 — 1200 2000 130% 277Y 277Y/480 3 Ph, 4 W + G 1500 — 1200 — 1200 2000 115% 347Y 347Y/600 3 Ph, 4 W + G 1500 480D 480 Delta 3 Ph, 3 W + G — — 1500 — — 1800 — 1500 2500 — 3000 115% 198% Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637-1738. Rev. 11/13 Data subject to change without notice www.geindustrial.com NOTE: For TVSS field installation kit, add the prefix “A” and replace “PP” suffix with “K” suffix Product # Example TPHE277Y15PP ATHE277Y15K BuyLog™ Catalog (factory installed) (field installation) 5-7 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ 9X and 24X Box Extensions Designed for GE “A Series™” Distribution Equipment This SPD model is installed in an extended box and connects to the "A Series™" Panelboard without adding width or depth to the panel enclosure and is ideal for aftermarket installations. These units have been tested to surge current ratings per NEMA LS-1, up to 200 kA per mode, including the fuses in the surge path. Standard features include a surge counter, audible alarm, indicating lights, dry contacts. Rating options range from 65 kA per mode to 300 kA per mode. All mode protection is provided with surge components (MOVs) connected on the phase-to-neutral, phase-to-ground, and neutralto-ground paths as appropriate for the voltage configuration. Tranquell™ 9X and 24X products are engineered for reliability, flexibility and long life in the most extreme surge environments. The true maximum surge current rating, unlimited by fusing, has been proven successful in 3rd party tests. Features and Benefits —UL1449, 3rd Edition —UL Tested to 200,000 Amperes Symmetrical Withstand for 24X —UL Tested to 65,000 Amperes Symmetrical Withstand for 9X —Field Installed with "A Series™" panels —Tranquell™ ME Device is Capable of Surviving a minimum of 5,000 Category C3 Impulses (10kA, 20kV) per mode. —Tranquell™ HE Device is Capable of Surviving a minimum of 20,000 Category C3 Impulses (10kA, 20kV) per mode. —Device Capable of Surviving a minimum of 5,000 Longwave (10x1000µs) Impulses per mode. —Form C Dry Contacts for Remote Monitoring —Green Status Indicating Lights, Red Service Light —Audible Alarm with Test/Disable Feature —Surge Counter —Standard 5 year limited warranty, Optional 20 year warranty Specifications Operating Frequency: Connection: Operating Temperature: Operating Humidity: Weight: 5-8 50/60 Hz 6 to 2/0 Conductors, Parallel Connected -40°C to +65°C 0% to 95% Non-Condensing 9X - 30 lbs., 12X - 52 lbs. BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ 9X and 24X Box Extensions Designed for GE “A Series™” Distribution Equipment 21.500 [546.10] 6.023 [152.98] 20.250 [514.35] 6.023 [152.984] 9.000 [228.60] 9.000 [228.6] 10.440 [265.18] 9.810 [249.174] 0.042 [1.067] 0.588 [14.94] 1.719 [43.675] 1.719 [43.67] 0.344 [8.738] 0.344 [8.74] 7.375 [187.338] 10.000 [254] 12.6255 [320.69] 15.400 [391.16] 7.375 [187.34] 10.000 [254.00] 12.625 [320.69] 15.400 [391.16] BX9F Dimensions BX9S Dimensions 21.500 [546.100] 20.250 [514.350] 6.023 [152.984] 9.000 [228.600] 6.412 [162.865] 6.023 [152.984] 9.000 [228.600] 7.042 [178.867] 9.810 [249.174] 10.440 [265.176] 1.617 [41.072] 7.239 [183.871] 0.588 [14.935] 2.247 [57.074] 6.609 [167.869] 13.624 [346.050] 14.254 [362.052] 2.389 [60.693] 2.389 [60.693] 0.344 [8.738] 7.375 [187.338] 10.000 [254.000] 12.625 [320.688] 15.400 [391.160] 15.400 [391.160] BX9WF Dimensions 7.085 [179.95] 6.333 [160.86] 12.560 [319.02] 5.390 [136.91] BX9WS Dimensions 6.074 [154.28] 6.899 [175.23] 7.624 [193.65] 7.085 [179.954] 6.810 [172.97] 6.333 [160.858] 0.711 [18.06] 21.500 [546.10] 20.280 [515.11] [8.738] 0.344 7.375 [187.338] 10.000 [254.000] 12.625 [320.688] 1.400 [35.56] 8.030 [203.96] 11.940 [303.276] 6.274 [159.360] 8.635 [219.33] 20.280 [515.112] 6.810 [172.969] 0.711 [18.059] 5.390 [136.906] 8.030 [203.962] 6.074 [154.280] 8.635 [219.329] 11.635 [295.529] 7.624 [193.650] 1.400 [35.560] 3.176 [80.67] 24.000 [609.60] 7.246 [184.048] 25.440 [646.18] Data subject to change without notice 3.176 [80.672] 7.246 [184.044] 24.743 [628.47] Rev. 11/13 24.000 [609.600] 24.743 [628.472] BX24WF Dimensions BX24WS Dimensions www.geindustrial.com BuyLog™ Catalog 5-9 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ 9X and 24X Box Extensions Designed for GE “A Series™” Distribution Equipment Tranquell™ 9X Box Extensions - 65 kA Symmetrical Fault Withstand Maximum Surge Current Enclosure Type A Series™ Extension Flush Mount A Series™ Extension Flush Mount A Series™ Extension Flush Mount A Series™ Extension Flush Mount A Series™ Extension Flush Mount 100kA per mode / 200kA per phase A Series™ Extension Flush Mount 65kA per mode / 130kA per phase A Series™ Extension Surface Mount A Series™ Extension Surface Mount A Series™ Extension Surface Mount A Series™ Extension Surface Mount A Series™ Extension Surface Mount A Series™ Extension Surface Mount 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase Description 9" Box Ext,Flush Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Flush Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Flush Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 9" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 9" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Access Display, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Access Display, Lights, Alarm, Counter, Contacts 9" Box Ext,Surface Mount, Access Display, Lights, Alarm, Counter, Contacts Product Number TPMEXXXX06BX9F TPMEXXXX08BX9F TPMEXXXX10BX9F TPMEXXXX06BX9WF TPMEXXXX08BX9WF TPMEXXXX10BX9WF TPMEXXXX06BX9S TPMEXXXX08BX9S TPMEXXXX10BX9S TPMEXXXX06BX9WS TPMEXXXX08BX9WS TPMEXXXX10BX9WS Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). Tranquell™ 24X Box Extensions - 65kA Symmetrical Fault Withstand Maximum Surge Current Enclosure Type A Series™ Extension Flush Mount A Series™ Extension Flush Mount 100kA per mode / 200kA per phase A Series™ Extension Flush Mount 65kA per mode / 130kA per phase A Series™ Extension Surface Mount A Series™ Extension Surface Mount A Series™ Extension Surface Mount 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase Description 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts Product Number TPMEXXXX06BX24WF TPMEXXXX08BX24WF TPMEXXXX10BX24WF TPMEXXXX06BX24WS TPMEXXXX08BX24WS TPMEXXXX10BX24WS Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). Tranquell™ 24X Box Extensions - 200kA Symmetrical Fault Withstand Maximum Surge Current Enclosure Type 100kA per mode / 200kA per phase A Series™ Extension Surface Mount 150kA per mode / 300kA per phase A Series™ Extension Surface Mount 200kA per mode / 400kA per phase A Series™ Extension Surface Mount 300kA per mode / 600kA per phase A Series™ Extension Surface Mount 100kA per mode / 200kA per phase A Series™ Extension Flush Mount 150kA per mode / 300kA per phase A Series™ Extension Flush Mount 200kA per mode / 400kA per phase A Series™ Extension Flush Mount 300kA per mode / 600kA per phase A Series™ Extension Flush Mount Description 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Surface Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts 24" Box Ext,Flush Mount, DisplayAccess, Lights, Alarm, Counter, Contacts Product Number TPHEXXXX10BX24WS TPHEXXXX15BX24WS TPHEXXXX20BX24WS TPHEXXXX30BX24WS TPHEXXXX10BX24WF TPHEXXXX15BX24WF TPHEXXXX20BX24WF TPHEXXXX30BX24WF Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). 5-10 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ 9X and 24X Box Extensions Designed for GE “A Series™” Distribution Equipment ME – Medium Exposure Level * 9S T Product # P - Surface mounted, no display 9WS - Surface mounted, display access 9F - Flush mounted , no display 9WF - Flush mounted, display access X * B ME – Medium Exposure & HE – High Exposure Level * 24WS - Surface mounted, display access 24WF - Flush mounted, display access Nominal System Voltage Voltage (Volts RMS) Configuration MCOV % Max. Continuous Operating Voltage Maximum Surge Current Capacity Exposure Level ME 120S 120/240 1 Ph, 3 W + G 125% 06 ME HE 120Y 120Y/208 3 Ph, 4 W + G 125% 08 220Y 220Y/380 3 Ph, 4 W + G 145% 10 240D 240 Delta 3 Ph, 3 W + G 115% 240H 120/240 Delta HL 3 Ph, 4 W + G 240Y 240Y/415 277Y 347Y 480D Per Mode Per Phase 65kA 130kA ME 80kA 160kA ME 100kA 200kA 12 HE 125kA 250kA 115% 15 HE 150kA 300kA 3 Ph, 4 W + G 130% 20 HE 200kA 400kA 277Y/480 3 Ph, 4 W + G 115% 25 HE 250kA 500kA 347Y/600 3 Ph, 4 W + G 115% 30 HE 300kA 600kA 480 Delta 3 Ph, 3 W + G 170% Product # Example Phase Rating = (L-N + L-G) Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637 1738. TPHE277Y15BX24WF —277Y/480 V, 3 Ph, 4 W + G —150kA per mode —Flush mounted, display access Voltage Protection Rating (VPR) UL 1449, 3rd Edition — September 2009 Revision BX9 L-N HL-N L-G HL-G 120S 1500 — 1500 — 120Y 1500 — 1500 220Y 1800 — 240D — — BX24 N-G L-L L-N HL-N L-G HL-G 900 1800 1500 — 1500 — 1000 1800 — 900 1800 1500 — 1500 — 1000 1800 2000 — 1500 2500 1800 — 1800 — 1500 2500 1800 — — — 1800 — — 2500 N-G — L-L 2500 240H 1500 1800 1500 2000 900 1800 1500 1800 1500 1800 1000 1800 240Y 1800 — 2000 — 1500 2500 1800 — 1800 — 1500 2500 277Y 1800 — 2000 — 1500 2500 1800 — 1800 — 1500 2500 347Y 2000 — 2000 — 1800 3000 3000 — 2500 — 1800 3000 480D — 2500 — — — 2500 — Rev. 11/13 Data subject to change without notice — — 4000 www.geindustrial.com — 4000 BuyLog™ Catalog 5-11 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount These devices are available in a standard NEMA 12 enclosure. Optional enclosure types include NEMA 12 and 4X, flushmount, surface mount and stainless steel. These units have been tested to surge current ratings per NEMA LS-1, up to 200kA per mode, including the fuses in the surge path. Standard features include a surge counter, audible alarm, indicating lights, dry contacts, and an integral surge rated disconnect (WMN1 and WMN4 only). Rating options range from 65kA per mode to 300 kA per mode. All mode protection is provided with surge components (MOVs) connected on the phase to neutral, phase to ground, and neutral to ground paths as appropriate for the voltage configuration. Tranquell™ HE and ME products are engineered for reliability, flexibility and long life in the most extreme surge environment. The true maximum surge current rating, unlimited by fusing, has been proven successful in 3rd party tests. Features and Benefits —UL1449, 3rd Edition CUL, UL1283 —UL Tested to 200,000 Amperes Symmetrical Withstand —Integral Surge Rated Disconnect —Tranquell™ ME Device is Capable of Surviving a minimum of 5,000 Category C3 Impulses (10kA, 20kV) per mode. —Tranquell™ HE Device is Capable of Surviving a minimum of 20,000 Category C3 Impulses (10kA, 20kV) per mode. —Device Capable of Surviving a minimum of 5,000 Longwave (10x1000µs) Impulses per mode. —Patented Thermal Fuse Technology in Combination with Surge Rated Fuses —Form C Dry Contacts for Remote Monitoring —Green Status Indicating Lights, Red Service Light —Audible Alarm with Test/Disable Feature —Surge Counter —Standard 10 year limited warranty, Optional 20 year warranty Specifications Operating Frequency: Connection: Operating Temperature: Operating Humidity: Weight: 50/60 Hz 6 to 2/0 Conductors, Parallel Connected -40°C to +65°C 0% to 95% Non-Condensing 50 lbs.: (THE), 32 lbs. (TME) *Must be installed downstream from breaker 60 Amp or less. 12.000 [304.80] 15.330 [389.38] 0.282 [ 7.16] HOLES (8 PLACES) 8.978 [228.04] 12.015 [305.18] 14.759 [374.88] 13.478 [342.34] 1.852 [47.04] 0.571 [14.50] [ 0.440 11.18] HOLE (2 PLACES) 0.625 [15.87] 18.759 [476.48] 16.000 [406.40] 15.478 [393.14] 3.852 [97.84] 26.500 [673.10] 24.000 [609.60] 0.571 [14.50] 1.471 [37.36] 6.440 [163.58] 19.330 [490.98] 15.330 [389.38] 0.625 [15.87] 8.978 [228.04] 9.276 [235.61] 1.250 [31.75] 12.000 [304.80] 12.000 [304.80] WMN12F Dimensions 5-12 BuyLog™ Catalog 10.750 [273.05] 0.440 [ 11.18] (2 PLACES) WMN1 Dimensions www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount Wall Mount Tranquell™ ME - 200kA Symmetrical Fault Withstand – Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase Enclosure Type Product Number NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel TMEXXXX065WMN12F TMEXXXX080WMN12F TMEXXXX100WMN12F TMEXXXX065WMN1 TMEXXXX080WMN1 TMEXXXX100WMN1 TMEXXXX065WMN12S TMEXXXX080WMN12S TMEXXXX100WMN12S TMEXXXX065WMN4S TMEXXXX080WMN4S TMEXXXX100WMN4S TMEXXXX065WMN4 TMEXXXX080WMN4 TMEXXXX100WMN4 TMEXXXX065WMN4X TMEXXXX080WMN4X TMEXXXX100WMN4X Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). Wall Mount Tranquell™ HE - 200kA Symmetrical Fault Withstand – Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase Enclosure Type Product Number NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel THEXXXX100WMN12F THEXXXX150WMN12F THEXXXX200WMN12F THEXXXX300WMN12F THEXXXX100WMN1 THEXXXX150WMN1 THEXXXX200WMN1 THEXXXX300WMN1 THEXXXX100WMN12S THEXXXX150WMN12S THEXXXX200WMN12S THEXXXX300WMN12S THEXXXX100WMN4S THEXXXX150WMN4S THEXXXX200WMN4S THEXXXX300WMN4S THEXXXX100WMN4 THEXXXX150WMN4 THEXXXX200WMN4 THEXXXX300WMN4 THEXXXX100WMN4X THEXXXX150WMN4X THEXXXX200WMN4X THEXXXX300WMN4X Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 5-13 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount WM N Product # Nominal Voltage (Volts RMS) System Voltage Configuration Voltage Protection Rating (VPR) UL 1449, 3rd Edition September 2009 Revision L–N HL–N L–G HL–G THE 120S 120/240 1 Ph, 3W + G 1000 — 1000 TME 120Y 120Y/208 3 Ph, 4W + G 1000 — 1000 — -— 220Y 220Y/380 3 Ph, 4W + G 1500 — 1500 — HL-L MCOV % Max. Continuous Operating Voltage 700 1200 -— 125% 700 1200 — 125% 065 ME 65kA 130kA 1000 2000 — 145% 080 ME 80kA 160kA N–G L-L 240D Exposure Level Per Mode Per Phase 240 Delta 3 Ph, 4W — — 1500 — — 1800 — 240H 120/240 Delta HL 3 Ph, 4W + G 1000 1500 1000 1500 700 1200 2500 196% 100 ME 100kA 200kA 115% 125 HE 125kA 250kA 240Y 240Y/415 3 Ph, 4W + G 1500 — 1500 — 1000 2000 — 130% 150 HE 150kA 300kA 277Y 277Y/480 3 Ph, 4W + G 1500 — 1500 — 1000 2000 — 115% 200 HE 200kA 400kA 347Y 347Y/600 3 Ph, 4W + G 1800 — 1500 — 1500 2500 — 115% 250 HE 250kA 500kA 480D 480 Delta 3 Ph, 4W — 2000 — 4000 — 198% 300 HE 300kA 600kA Product # Example THE277Y150WMN12S 5-14 Maximum Surge Current Capacity BuyLog™ Catalog — — Suffix Description NEMA Enclosure Mounting Disconnect 1 Painted Steel 1 Surface Yes 12S Painted Steel 12 Surface No 12F Painted Steel 12 Flush No 4 Fiberglass 4X Surface Yes 4S Painted Steel 4 Surface No 4X Stainless Steel 4X Surface No www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount, with Enhanced Thermal Protection Introduction Recommended installation locations are primary and secondary distribution and point of use levels. Designed for distribution and point of use locations, but rated for service entrance, the Tranquell™ HE and ME with enhanced thermal protection has been third-party tested to ANSI/IEEE C3 10kA 8x20µs impulses. The entire Tranquell™ HE and ME line-up has been engineered to the highest standards and is designed for rigorous duty and long life, as evidenced in our outstanding minimum repetitive surge current capacity test results. These devices are available in a standard NEMA 12 enclosure. Optional enclosure types from NEMA 12 – NEMA 4x include flush mount, surface mount, fiberglass and stainless steel. These units have been tested to surge current ratings per NEMA LS-1, up to 200kA per mode, 400kA per phase. Standard features include a surge counter, audible alarm, indicating lights, dry contacts, and an integral surge rated disconnect. Rating options range from 65kA – 300kA per mode, 130kA – 600kA per phase. GE engineers design and build transient voltage surge suppressors in our state-of-the-art lab and production facilities. Extensive testing is performed at GE and third-party test labs across North America. Production is carried out at our factory in Bonham, Texas utilizing Six Sigma, ISO 9001 methodologies and lean manufacturing processes. Features and Benefits Specifications Operating Frequency 50/60 Hz Connection 6 to 2/0 Conductors, Parallel Connected Operating Temperature -40° F to 140° F (-40° C to +65° C) Operating Humidity 0% to 95% Non-Condensing Weight NEMA Enclosure Suffix: 1 63 lbs. (28.5 kg) 4 56 lbs. (25.4 kg) 4S, 12S, 12F 44 lbs. (20.0 kg) 4X 50 lbs. (22.7 kg) —UL 1449 3rd Edition, September 2009, cUL —UL 1283 noise filtering. The TVSS device EMI-RFI noise rejection or attenuation value is measured in accordance with the procedures outlined in NEMA LS 1-1992 (R2000)/MIL–STD-220B. Attenuation is -50db minimum @ 100kHz. —UL tested to 200,000 amperes symmetrical withstand —Integral surge rated disconnect —Tranquell™ ME device is capable of surviving a minimum of 5,000 category C3 impulses (10kA, 20kV) per mode —Tranquell™ HE device is capable of surviving a minimum of 20,000 category C3 impulses (10kA, 20kV) per mode —Thermally protected MOVS eliminate the need for additional upstream fuses —NO/NC Form C dry type contacts for remote monitoring —Green status indicating lights, red service light —Audible alarm with test/disable feature —Standard LCD surge counter —10 year limited warranty (standard), 20 year limited warranty (optional) Rev. 11/13 Data subject to change without notice www.geindustrial.com BuyLog™ Catalog 5-15 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount, with Enhanced Thermal Protection 12.000 [304.80] 20.000 [508.00] 12.015 [305.18] 12.651 [321.34] 0.440 [ 11.18] HOLE (2 PLACES) 0.625 [15.87] 26.500 [673.10] 24.000 [609.60] 25.500 [647.70] 24.000 [609.60] 0.625 [15.87] 9.276 [235.61] 1.250 [31.75] 0.440 [ 11.18] (2 PLACES) 10.750 [273.05] 12.000 [304.80] 21.500 [546.10] 9.912 [251.76] WMN4 Dimensions WMN1 Dimensions 15.330 [389.38] [ 0.282 7.16] HOLES (8 PLACES) 8.978 [228.04] 14.759 [374.88] 13.478 [342.34] 1.852 [47.04] [ 9.226 [234.33] 10.399 [264.14] 0.380 9.65] HOLE (4 PLACES) 0.571 [14.50] 18.759 [476.48] 16.000 [406.40] 15.478 [393.14] 19.118 [485.61] 19.330 [490.98] 17.659 [448.53] 3.852 [97.84] 0.571 [14.50] 1.471 [37.36] 1.475 [37.46] 15.330 [389.38] 6.440 [163.58] 6.439 [163.56] 11.999 [304.77] 8.978 [228.04] 9.226 [234.33] 12.000 [304.80] WMN12S, WMN4S, WMN4X Dimensions WMN12F Dimensions Wall Mount Tranquell™ ME - 200kA Symmetrical Fault Withstand – Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase 65kA per mode / 130kA per phase 80kA per mode / 160kA per phase 100kA per mode / 200kA per phase Enclosure Type Product Number NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel TPMEXXXX06WMN12F TPMEXXXX08WMN12F TPMEXXXX10WMN12F TPMEXXXX06WMN1 TPMEXXXX08WMN1 TPMEXXXX10WMN1 TPMEXXXX06WMN12S TPMEXXXX08WMN12S TPMEXXXX10WMN12S TPMEXXXX06WMN4S TPMEXXXX08WMN4S TPMEXXXX10WMN4S TPMEXXXX06WMN4 TPMEXXXX08WMN4 TPMEXXXX10WMN4 TPMEXXXX06WMN4X TPMEXXXX08WMN4X TPMEXXXX10WMN4X Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). 5-16 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ HE and ME Wall Mount, with Enhanced Thermal Protection Wall Mount Tranquell™ HE - 200kA Symmetrical Fault Withstand – Lights, Alarm, Surge Counter, Form C Contacts Maximum Surge Current 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase 100kA per mode / 200kA per phase 150kA per mode / 300kA per phase 200kA per mode / 400kA per phase 300kA per mode / 600kA per phase Enclosure Type Product Number NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Flush NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface, Integral Disconnect NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 12 Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4 Painted Steel Surface NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Fiberglass, Integral Disconnect NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel NEMA 4X Stainless Steel TPHEXXXX10WMN12F TPHEXXXX15WMN12F TPHEXXXX20WMN12F TPHEXXXX30WMN12F TPHEXXXX10WMN1 TPHEXXXX15WMN1 TPHEXXXX20WMN1 TPHEXXXX30WMN1 TPHEXXXX10WMN12S TPHEXXXX15WMN12S TPHEXXXX20WMN12S TPHEXXXX30WMN12S TPHEXXXX10WMN4S TPHEXXXX15WMN4S TPHEXXXX20WMN4S TPHEXXXX30WMN4S TPHEXXXX10WMN4 TPHEXXXX15WMN4 TPHEXXXX20WMN4 TPHEXXXX30WMN4 TPHEXXXX10WMN4X TPHEXXXX15WMN4X TPHEXXXX20WMN4X TPHEXXXX30WMN4X Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). Product # T Nominal Voltage (Volts RMS) P System Voltage Configuration W M Voltage Protection Rating (VPR) UL 1449, 3rd Edition September 2009 L–N HL–N L–G HL–G N–G L–L — 800 — 700 1200 N MCOV % HL–L Max. Continuous Operating Voltage — 125% 06 ME 65kA Maximum Surge Current Capacity ME 120S 120/240 1 Ph, 3W + G 900 HE 120Y 120Y/208 3 Ph, 4W + G 900 — 800 — 700 1200 — 125% 220Y 220Y/380 3 Ph, 4W + G 1500 — 1200 — 1200 2000 — 145% 08 ME 80kA 160kA 240D 240 Delta 3 Ph, 4W — 1200 — 1800 — 196% 10 ME 100kA 200kA — — Exposure Level Per Mode Per Phase 130kA 240H 120/240 Delta HL 3 Ph, 4W + G 1000 1200 800 1200 700 2000 2200 115% 12 HE 125kA 250kA 240Y 240Y/415 3 Ph, 4W + G 1500 — 1200 — 1200 2000 — 130% 15 HE 150kA 300kA 277Y 277Y/480 3 Ph, 4W + G 1500 — 1200 — 1200 2000 — 115% 20 HE 200kA 400kA 347Y 347Y/600 3 Ph, 4W + G 1500 ---- 1500 ---- 1500 2500 ---- 115% 25 HE 250kA 500kA 480D 480 Delta 3 Ph, 4W 198% 30 HE 300kA 600kA ---- ---- 1800 ---- ---- 3000 ---- Also available in 600D configurations. For details, please contact GE Power Quality Customer Service at 800 637 1738. Phase Rating = (L-N + L-G) Product # Example TPHE277Y15WMN12S —277Y/480 V, 3 Ph, 4 W + G —150kA per mode —Surface mount enclosure without disconnect —Painted steel Rev. 11/13 Data subject to change without notice www.geindustrial.com Suffix Description NEMA Enclosure Mounting Disconnect 1 Painted Steel 1 Surface Yes 12S Painted Steel 12 Surface No 12F Painted Steel 12 Flush No 4 Fiberglass 4X Surface Yes 4S Painted Steel 4 Surface No 4X Stainless Steel 4X Surface No BuyLog™ Catalog 5-17 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ ME and LE Wall Mount The Tranquell™ ME and LE feature compact, economical, universal designs for use at medium exposure, distribution or branch panels and are available in a standard NEMA 12 enclosure. These devices have been tested to surge current ratings per NEMA LS-1, including the fuses in the surge path. These units come standard with indicating lights and dry contacts. Ratings are available from 25kA per mode to 100kA per mode. These surge protection devices provide all mode protection, with surge components (MOVs) connected on the phase- to-neutral, phase-to-ground, and neutral-to-ground paths as appropriate for the voltage configuration. Features and Benefits —Universal design allows for easy retrofit installation —UL1449, 3rd Edition cUL —Tranquell™ ME devices with UL1283 Noise Filters —UL Tested to 65,000 Amperes Symmetrical Withstand —Tranquell™ ME Device is Capable of Surviving a minimum of 5,000 Category C3 Impulses (10kA, 20kV) per mode —Tranquell™ ME Device Capable of Surviving a minimum of 5,000 Longwave (10x1000ms) Impulses per mode —Tranquell™ LE Device is Capable of Surviving a minimum of 3,500 Category C3 Impulses (10kA, 20kV) per mode —Form C Dry Contacts for Remote Monitoring —Green Status Indicating Light(s) —Standard 10 year limited warranty, Optional 20 year warranty Specifications Operating Frequency: Connection: Operating Temperature: Operating Humidity: Weight: 50/60 Hz 10 AWG Conductors, Parallel Connected -40°C to +65°C 0% to 95% Non-Condensing (TME) 19 lbs., (TLE) 11.4 lbs. *Must be installed downstream from 60 Amp breaker or less. TME TLE 4.00 3/4" N.P.T. 6.75 6.25 7.50 6.25 4.37 2.85 1.55 6.00 5-18 BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ ME and LE Wall Mount Wall Mount Tranquell™ ME and LE - 65 kA Symmetrical Fault Withstand Maximum Surge Current 25 kA per mode / 50 kA per phase 50 kA per mode / 100 kA per phase 65 kA per mode / 130 kA per phase 80 kA per mode / 160 kA per phase 100 kA per mode / 200 kA per phase Enclosure Type Description Product Number NEMA 12 NEMA 12 NEMA 12 NEMA 12 NEMA 12 Lights, Form C Contacts Lights, Form C Contacts Lights, Form C Contacts Lights, Form C Contacts Lights, Form C Contacts TLEXXXX025WM TLEXXXX050WM TMEXXXX065WM TMEXXXX080WM TMEXXXX100WM Note: Replace XXXX in Product Number with nomenclature for Nominal Voltage (Volts RMS). * Voltage Protection Rating, UL1449, 3rd Edition ** Maximum Continuous Operating Voltage Product # WM TLE Voltage Protection Rating (VPR) UL 1449, 3rd Edition September 2009 HL–G N–G L–L HL–L — 600 1000 — 125% — 600 1000 — 125% — 1200 1800 — 145% — — 1800 — 196% 600 1000 600 1000 1800 115% — 1000 — 1200 1800 — 130% 1200 — 1000 — 1200 1800 — 115% — — 1800 — — 4000 — 198% System Voltage Configuration L–N HL–N L–G — 600 — 600 — 1000 — 900 600 1200 3 Ph, 4W + G 1200 277Y/480 3 Ph, 4W + G 480 Delta 3 Ph, 4W TLE 120S 120/240 1 Ph, 3W + G 600 TME 120Y 120Y/208 3 Ph, 4W + G 600 220Y 220Y/380 3 Ph, 4W + G 1200 240D 240 Delta 3 Ph, 4W — 240H 120/240 Delta HL 3 Ph, 4W + G 240Y 240Y/415 277Y 480D Rev. 11/13 Data subject to change without notice www.geindustrial.com MCOV % Max. Continuous Operating Voltage Nominal Voltage (Volts RMS) 025 25kA per mode 50 kA per phase (TLE) 050 50kA per mode 100 kA per phase (TLE) 065 65 kA per mode 130 kA per phase (TME) 080 80 kA per mode 160 kA per phas e (TME) 100 100 kA per mode 200 kA per phase (TME) BuyLog™ Catalog 5-19 Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ DIN Rail Mount The full-featured Tranquell™ DIN Rail Mount SPD (Surge Protection Device) is a Type 2 surge protection device that is modular and easy to install. DIN Rail mount housing allows for quick installation. Each unit has a compact footprint and user-replaceable phase surge pluggable modules with an IP20 finger-safe design. Both visual indicators and remote indicators (dry contact) provide SPD status to critical control circuits. Features and Benefits —Built-in thermal protection —200kA interrupting rated —DIN Rail mount —Pluggable modules, finger-safe design – IP20 rating —Built-in visual status indicator —Remote indicator with 3 pin COM/NO/NC contacts —Easy installation or retrofit —Fail-safe / self-protected design —Small footprint —No external fusing or circuit breakers required —Standard 5 year limited warranty, optional 20 year warranty Dimensional Diagrams 3.89 98.9 .35 8.9 .60 15.2 .70 17.8 Poles A 1-Pole 0.71 in [18 mm] 2-Pole 1.42 in [36 mm] 3-Pole 2.13 in [54 mm] 4-Pole 2.84 in [72 mm] A .15 3.9 Specifications —UL1449, 3rd edition (September 2009) —UL type 2 device —RoHS compliant —ANSI/IEEE C62.41 5-20 BuyLog™ Catalog 2.00 50.7 2.82 71.8 Microswitch .44 11.1 NOTE: All dimensions in the diagram above are for reference only and are shown in Inches [millimeters] www.geindustrial.com Rev. 11/13 Data subject to change without notice Surge Protection Device (SPD) Section 5 Critical Power Products Tranquell™ DIN Rail Mount Product Numbers and Specifications Product Configuration Nominal Voltage (50/60 Hz) Product Number TD120Y4025RMN TD120Y4050RMN TD277Y4025RMN TD277Y4050RMN TD347Y4025RMN TD347Y4050RMN TD240H4025RMN TD240H4050RMN TD480H4025RMN TD480H4050RMN TD120Y3025RMP TD120Y3050RMP TD277Y3025RMP TD277Y3050RMP TD347Y3025RMP TD347Y3050RMP TD240D3025RMP TD240D3050RMP TD480D3025RMP TD480D3050RMP TD120S2025RMP TD120S2050RMP TD240S2025RMP TD240S2050RMP TD120S1025RMP TD120S1050RMP TD240S1025RMP TD240S1050RMP TD277S1025RMP TD277S1050RMP TD347S1025RMP TD347S1050RMP No. of Wires 120 / 208V 277 / 480V 347 / 600V 5-Wire / 4 Pole 120 / 240V 240 / 480V 120 / 208V 277 / 480V 347 / 600V 4-Wire / 3 Pole 240V 480V 120 / 208V, 120 / 240V 240 / 480V 3 Wire / 2 Pole 120V 240V 277V 2 Wire / 1 Pole 347V Max Discharge Current (Imax, 8/20 µs, kA) 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA 25kA 50kA Wiring Configuration* 3 Phase Wye, plus N-G 3 Phase High Leg Delta 3 Phase Wye, common N/G 3 Phase Delta Split Phase Single Phase UL Specifications Nominal Electrical Discharge Voltage Current MCOV MCOV MCOV Configuration** (In, kA) (Vc) L-L (Vc) L-G (Vc) L-N 20 360 360 180 20 360 360 180 20 640 500 320 Figure C 20 640 500 320 10 840 695 420 10 840 695 420 20 20 *** Figure E 10 10 — 20 360 180 20 360 — 180 20 640 320 Figure C — 20 640 320 10 840 420 10 840 420 20 550 275 — 20 550 275 — Figure D 10 1100 550 10 1100 550 — 20 360 180 20 360 — 180 Figure B — 20 550 275 20 550 275 — — 20 180 20 — — 180 20 275 20 275 Figure A — — 20 320 20 320 10 420 10 420 Voltage Protection Rating (VPR) (Up @ In) L-N 600 600 1000 1000 1500 1500 600 600 900 900 600 600 1000 1000 1500 1500 — — 600 600 900 900 600 600 900 900 1000 1000 1500 1500 L-G 1200 1200 1500 1500 2000 2000 1200 1200 1500 1500 — — N-G 600 600 600 600 900 900 600 600 600 600 — — 900 900 1800 1800 — — — — — — — — — — L-L 1200 1200 1800 1800 2500 2500 1200 1200 1800 1800 1200 1200 1800 1800 2500 2500 1800 1800 3000 3000 1200 1200 1800 1800 — — — — — — — H-L1 — — H-N — — H-G — 1500 1500 2500 2500 — — — 900 900 1800 1800 — — — — — — — — — — — — — — — — — — — — — — — 1500 1500 2000 2000 — ***Please contact the factory for details Configuration Diagrams (NOTE: Shown(NOTE with no power applied) **Wiring Wiring Configuration Diagrams : Shown with no power applied) SINGLE PHASE 3 PHASE DELTA / 3 PHASE WYE, COMMON N/G SPLIT PHASE L1 L L2 L1 L2 L3 3 PHASE HIGH LEG DELTA / 3 PHASE WYE, PLUS N-G L2 L1 L3 G G/N G/N G/N N **Electrical Voltage Configurations ** Electrical Voltage Configurations L L1 L1 L1 L3 L2 N N N N G L2 G L2 L3 G L3 G L1 L2 FIGURE A FIGURE B FIGURE C FIGURE D FIGURE E Single Phase 2 Wire + Ground Split Phase 3 Wire + Ground 3 Phase Wye 4 Wire + Ground 3 Phase Delta 3 Wire + Ground 3 Phase Delta Hi-Leg 4 Wire + Ground Rev. 11/13 Data subject to change without notice www.geindustrial.com NOTE: GE’s Tranquell™ Series SPD DIN Rail mount devices are tested for safe operation without any dedicated overcurrent protection, when correctly matched to the power system parameters. A gG 160 Amp NH Fuse may be chosen to meet other requirements in an IEC application. Consult local codes and standards for appropriate fuse sizing. BuyLog™ Catalog 5-21 Surge Protection Device (SPD) Section 5 Critical Power Products Protection Block Assembly–Surge Protection Device Introduction The GE 427 patented 5 Pin Protection Block Assembly is equipped with a multi-layered printed circuit board, providing a connectorized interface for cable assemblies. It accommodates 25, 50 or 100 pair cable. It is used in many applications, including: central offices, remote switching sites, customer premises and building entrances, to protect telephone and voice/data lines. When wiring cabinets with conventional wire wrap blocks each block becomes a different part number and causes difficulty for OEMs who have to inventory parts. The same GE 427 Protection Block Assembly is used in every position of a cabinet or mainframe. The cables are now treated as less expensive parts and are stocked by length and mating connector type. Manual labor, in running cables and making wire wrap connections, is reduced significantly by employing GE Connectorized Block Assemblies. Performance Features —Gold pins and sockets ensure proper electrical connections —Self-locking aluminum hood (optional) provides protection to connectors and printed circuit board and serves as the cable strain relief tie point —Multi-layered printed circuit board —Handle heavy transient current surges —U.S. Patent No. 5,457,593 Protection Block Assembly Protection Block Assembly–Surge Protection Device Pair Block Type Hood Product Number 50 Marconi Block YES 427-050-202 100 Avaya Block YES 427-100-102 100 Marconi Block YES 427-100-202 100 Corning Block YES 427-100-302 Benefits —Provides maximum reliability by eliminating all wire wraps —Provides the high quality installation of a protection block —Provides additional flexibility for equipment installations —Easily serviceable in the field —Eliminates the need for wire wrapping —Allows connectorization into many different applications and greatly reduces installation, labor and repair costs —All cables connected to this unit can be removed, permitting specific cable change out or change out of the entire protection block assembly. This allows the protected equipment to quickly be put back into service. —Covered by a two year limited product warranty Specifications Voltage Class: BIL rating: Primary Currents: 5-22 600 V 10 kV 10 to 5000 amps BuyLog™ Catalog www.geindustrial.com Rev. 11/13 Data subject to change without notice
Similar documents
Datasheet - Littelfuse
• Meet MSL level1, per J-STD-020, LF maximun peak of 260°C • Matte tin lead–free plated
More information