check/drop

Transcription

check/drop
2015
www.precon.ca
2
2014 PROJECTS
TABLE OF CONTENTS
2
2014 PROJECTS
3
TABLE OF CONTENTS
4
CATCH BASINS
5
MANHOLE MATERIALS
6
LARGE DIAMETER ROUND MANHOLES
7
ROUND CONNECTION OPTIONS
8
STANDARD VAULTS
9
MULTI-PANEL VAULTS
10 STORM POND STRUCTURES
20 VALUE ADDED ACCESSORIES
21
PRECAST SLABS/BASES
22
MECHANICAL
23
MECHANICAL
3
11
POLYETHYLENE LINED PRODUCTS
12
IMPACT BAFFLES
13
INLET/TURNOUTS
14
CHECK STRUCTURES
15
CHECK/DROP STRUCTURES
16
PANEL WALLS
17
BUILDINGS
18
TRENCH DRAINS/UTILITY DUCTS
19
FLAT WALL PIPE CONNECTIONS
4
CATCH BASINS
CATCH BASIN MATERIAL
Precon manufactures several Catch Basin pieces including tops, barrels, bases and adjuster
rings to accommodate the requirements of Alberta various cities and municipalities.
For Catch Basin Manhole materials please see Manhole Material on page 5.
USES
1. Municipal storm sewer infrastrucure
2. Leachate Collection Systems
SIZES
Precon manufactures both 600mm and 900mm
diameter catch basin material.
Precon is committed to maintaining a wide range of
catch basin material in stock. There are many different
sizes ranging from 1220mm monobases to 1200mm
high barrels. Any desired height can be easily achieved.
MANHOLE MATERIALS
5
MANHOLE MATERIALS
Precon’s precast concrete Manhole Materials are a combination of tops, barrels and bases and when
configured, allow the creation of manhole systems to suit a variety of needs. Custom Prebench Bases
are built to specification, with sized pipe connections at the appropriate angle, height and slope.
Bases are also prebenched with the correct trough, making installation easy, fast and worry-free.
Precon’s Slab Tops come in a variety of openings to suit any installation.
USES
1. Municipal Infrastructure
2. Lift Stations
3. Leachate collection systems
4. Toe drain collection systems
SIZES
Precon has a wide range of manhole material in stock.
There are many different sizes, ranging from 2000mm high
barrels to 50mm high grade rings. Any desired height can easily
be achieved.
6
LARGE DIAMETER ROUND MANHOLES
LARGE DIAMETER MATERIAL
Precon’s large diameter precast concrete Manhole Materials also consist of a combination of
tops, barrels and bases and when configured, allow the creation of manhole systems to suit
a variety of needs. Precon provides custom Prebench Bases for its large diameter Manholes
too. Like the standard 1200mm diameter Manholes, the large diameter Manholes are built to
specification, with sized pipe connections at the appropriate angle, height and slope. Bases are
also prebenched with the correct trough, making installation easy, fast and worry-free.
Precon’s Slab Tops come in a variety of openings to suit any installation.
USES
1. Municipal Infrastructure
2. Lift Stations
3. Leachate Collection Systems
4. Toe Drain Collection Systems
SIZES
Precon has a wide range of 1500mm, 1800mm and
2400mm manhole material in stock. Any desired
height can easily be achieved.
ROUND CONNECTION OPTIONS
CONNECTIONS INCLUDE:
Boot Connection
Grout Connection
Kwik Seal Connector™
Link Seal™
PVC Stub
A-Lok™
7
8
STANDARD VAULTS
STANDARD VAULTS
One of Precon’s most versatile products, the Standard Vault is an engineered, concrete box that
can be used in a variety of applications from manholes to water meter chambers.
Precon’s Standard Vaults are typically used to accommodate smaller vault installations. These
stackable pieces are available in standard 400mm increment riser sections so that the required
structure height is easily achieved. Custom riser heights are also available.
The Standard Vault piece, much like the rest of our product line, can also have many different types
of accessories cast in. It can also be poured with almost any size of hole. These pieces are quick
and easy to install.
USES
1. Municipal Infrastructure
2. Lift Stations
3. Valve Chambers
4. Drain Chambers
5. Air Valve Chambers
6. Water Reservoirs
7. Water Meter Chambers
8. Pump Stations
9. Storm Pond Control Structures
MULTI-PANEL VAULTS
9
MULTI-PANEL VAULTS
Precon’s Multi-Panel Vault Structure is an engineered, multi-piece structure that is assembled
on-site. The Multi-Panel Vault is typically used to accommodate larger vault installations. The structure
is highly versatile in its assembly. Large structures can be designed, produced and shipped with
minimal assembly. Typically, installation and backfill can be achieved in one day. This structure can
accommodate all kinds of pipe penetrations, grout holes, thimbles and personnel access.
Integrated splitter walls, weir walls and intermediate floors are also possible with
Multi-Panel Vaults allowing for wet well/dry well combinations, energy dissipation and access to large
mechanical or valve equipment.
The installation process provides unique opportunities for accommodating difficult installations.
For instance, when installing large diameter water mains with valve assemblies, a portion of the
structure can be installed, followed by the installation of the interior piping and valve assembly and
completed with the installation of the remaining pieces of the structure.
USES
1. Large Vaults Exceeding Standard Vault Sizing
2. Lift Stations
3. Valve Chambers
4. Drain Chambers
5. Air Valve Chambers
6. Water Reservoirs
7. Water Meter Chambers
8. Pump Stations
9. Storm Pond Control Structures
SIZES
Multi-Panel vaults can be produced in sizes up to and including 5000mm ID x 65000mm ID. The width
and length are in increments of 250mm and the height is in increments of 250mm. All Multi-Panel
Vaults range from 1250mm – 8000mm inside height with wall thicknesses of 204mm or 254mm.
10
STORM POND STRUCTURES
STORM POND STRUCTURES
Precon’s Storm Pond Structures are engineered structures consisting of Standard or Multi-Panel
Vaults. These storm pond structures can be used in a variety of applications, with or without weir
walls and built to accommodate gates and ICD control devices, and super catch basin vaults.
Precon vaults can accommodate grated, straight, or sloped tops to be used as large catch basins.
These structure tops can accommodate a variety of slopes.
The storm pond structures, like the rest of our product line, can also have many of the different
types of accessories cast in, or can be poured with almost any size of rough hole.
POLYETHYLENE LINED PRODUCTS
11
POLYETHYLENE LINED PRODUCTS
Precon can cast a polyethylene liner onto the inner surface of most of our products*. The polyethylene
liner protects against corrosion, permeation and groundwater intrusion.
Precon’s polyethylene liner is resistant to most acids, bases, hydrocarbons, vapors and microbiological
attacks.
For more details please see www.precon.ca
* requires field welding at joints
12
IMPACT BAFFLES
IMPACT BAFFLES
Precon’s Impact Baffle Structure is an outlet style structure, with an engineered basin and
headwall, designed to dissipate energy as water is introduced into a drainage system or natural
water course. The dissipation of energy is controlled by a baffle wall that is cast into the structure
and can handle flows up to 5.6m3/second. The headwall is also constructed with a unique
anchoring system that acts as a seepage barrier.
The Impact Baffle is easy to handle and install. It has been designed to USBR standards and
Precon can accommodate many different thimbles or pipes that can be cast directly into the
structure.
USES
1. Pipeline terminal structures requiring energy
dissipation during normal or event type flow situations
SIZES
Precon’s Impact Baffle Structures are produced in five
standard sizes to accommodate flows between
0.4m3/second to 5.6m3/second and pipe sizes up to
1350mm diameter.
INLET/TURNOUTS
13
INLET/TURNOUTS
Precon’s Inlet/Turnout Structure is an engineered structure consisting of a headwall and basin
designed for water inlet and outlet control. The structure is exceptionally easy to handle and install
and the unique design of the headwall acts as an anchoring system as well as a seepage barrier.
The Inlet/Turnout is ideal for municipal, irrigation and farm turnouts or pond inlets. This structure
compliments Precon’s Check and Check/Drop structures, creating a system that allows efficient
water control in a water conveyance system.
The Inlet/Turnout is designed based on the shape of the canal or existing topography, required flow,
and pipe size. Several different types of connection accessories (eg. 86 or 150 psi thimbles) can also
be cast into the headwall that can accommodate numerous gates, pipe thimbles and valves with a
variety of bolt hole patterns.
USES
1. Inlets for Irrigation Pipelines
2. Inlet/Turnout for Irrigation Water Delivery
3. Inlet/Turnout for Storm Pond Control
4. Outlet for Drainage Control
SIZES
Precon Inlet/Turnouts sizes are sized based on the slope of the
canal or pond and the size of the conveyance pipe. Precon can
accommodate slopes of 2:1, 2.5:1 and 3:1.
14
CHECK STRUCTURES
CHECK STRUCTURES
Precon’s Check Structure is a multi-piece (typically using between 9 and 13 pieces) precast
concrete structure that assembles in the shape of an ‘H’ and is installed in an irrigation canal
perpendicular to the flow of water. The shape of the structure provides a double water cutoff,
helping to prevent bank erosion by ensuring that water cannot migrate around or under the
structure.
The Check Structure is engineered and designed to USBR standards and is a reliable solution for
water level control in a water conveyance system. The Check Structure allows the designer to
control water levels and water velocity. It works well in conjunction with Precon’s Inlet/Turnout as
a way to obtain necessary water levels for water delivery.
The structure is designed for canals with flows as large as 3.5m3/second. The width of the
canals at the top and bottom, the flow of water, and the type of gate are taken into account when
designing. The structure can accommodate Overshot gates, Stop Log Systems and several other
popular gate systems. The Check Structure can also be used to measure the flow of the water.
USES
1. Level control in the storage, delivery and
drainage of water systems
2. Weir Structure
SIZES
Precon’s Check Structures are produced in many different
sizes to accommodate the specific application. Size depends
on flow. Precon can design structures for flows between
1.0m3/second to 3.5m3/second.
CHECK/DROP STRUCTURES
15
CHECK/DROP STRUCTURES
Precon’s Check/Drop Structure is a multi-piece (typically using 9-13 pieces) precast concrete
structure that assembles in the shape of an ‘H’ and is installed in an irrigation canal perpendicular to
the flow of water. The shape of the structure provides a double water cutoff, helping to prevent bank
erosion by ensuring that water cannot migrate around or under the structure.
The Check/Drop Structure is engineered and designed to USBR standards and is a reliable solution
for water level and grade control in a water conveyance system, where there is also a change in
elevation. The Check/Drop Structure allows the designer to control water levels and water velocity.
It works well in conjunction with Precon’s Inlet/Turnout as a way to obtain necessary water levels for
water delivery.
The structure is designed for canals with flows as large as 3.0m3/second. The width of the canal at
the top and bottom, the flow of water and the type of gate are taken into account when designing the
structure. The structure can accommodate Overshot gates, Stop Log Systems and several other
popular gate systems. The Check/Drop Structure can also be used to measure the flow of the water.
USES
1. Level and grade control in the storage, delivery and drainage
of water systems where there is a change in elevation
2. Weir Structure
3. Check/Drop Structure
4. Drop Structure
SIZES
Precon Inlet/Turnouts sizes are sized based on the slope of the canal or pond and the size of the
conveyance pipe. Precon can accommodate slopes of 2:1, 2.5:1 and 3:1.
16
PANEL WALLS
PANEL WALLS
Precon’s precast concrete Panel Walls are constructed using smaller, more manageable pieces
that are assembled to make a wall of any length. The Panel Wall is engineered and designed
based on the opening required and the depth necessary to eliminate seepage. The product is
shipped in pieces. On site, it is easily assembled, making it ideal for remote areas. Stability of the
wall must be taken into account when selecting this structure
USES
1. Simple Canal Weir Structure
2. Pond Level Control
SIZES
Panel Walls can be built to a maximum height
of 4000mm and any length. Wall pieces can be
poured 152mm, 204mm or 254mm thick.
BUILDINGS
17
BUILDINGS
Precon’s precast concrete Building is an engineered, two piece structure that combines a safe,
secure location for electrical, computer or automated equipment with a maintenance-free exterior.
The precast concrete Building, when equipped with a heavy duty steel door, is vandal resistant. It is
water tight, fire resistant and vermin proof, making it ideal in harsh environments.
The precast concrete Building can be insulated (R20) and several other accessories or options can be
built in. Installation is quick and easy and, when compared with alternative steel or wood products, the
precast concrete Building provides a long lasting solution.
USES
1. Control Buildings
2. Generator Sites
3. Accessory to Lift or Pump Stations
4. Mechanical Room
SIZES
Precon’s Buildings are produced in four standard sizes
BD2025 (2.0m OD x 2.5m OD), BD2530 (2.5m OD x 3.0m OD),
BD3040 (3.0m OD x 4.0m OD), BD3050 (3.0m OD x 5.0m OD).
Insulation can vary in thickness depending on the application.
18
TRENCH DRAINS/UTILITY DUCTS
TRENCH DRAINS/UTILITY DUCTS
Trench Drains/Utility Ducts are engineered, 3-sided concrete boxes that can be used in a wide
variety of applications from cableways to fluid conveyance trenches. Precon’s Standard Trenches
are available in a wide variety of spans from 508mm to 4000mm wide. These connectable pieces
are also available with a variety of tops types (eg. CL-800 precast tops and grating tops).
Trench Drains/Utility Ducts, much like the rest of our product line, can also have many different
types of accessories cast in. It can also be poured with almost any size of hole. These pieces are
quick and easy to install.
USES
1. Trench Drains
2. Utility Ducts
3. Cableways
4. Rupture Disk Trenches
FLAT WALL PIPE CONNECTIONS
19
CONNECTIONS INCLUDE:
Weldable ‘F’ Thimble
Boot Connection
‘F’ Type Thimbles
Grout Connection
Steel Sleeve
Link Seal
‘E’ Type Thimbles
Kwik Seal Connection
20
VALUE ADDED ACCESSORIES
PRECON HAS A WIDE VARIETY OF
ACCESSORIES INCLUDING:
• Ladder Rungs
• Ladder Extensions
• Hatches
• Lifting Devices
• Grates, Walkways and Safety Platforms
• Water Control Gates
• LIfting Davits
• Trash Racks
• Inlet Control Devices
• Various Sealants
HYDROGUARD
HYDROGUARD
Stormwater Hydrodynamic Separator
• Treats storm water quality
• Treats Low and High Flows
• Separate low flow path prevents scour at high flows
• Separate high flow path captures floatables
• Captures oil spills, TSS and trash
• Small footprint
• Engineered for traffic loading
• Can be used as a inlet or a bend structure
• Sized based on independent TSS removal results,
local hydrology and continuous simulation
• Vertical baffles and multiple access points
HYDROGUARD WATER QUALITY FLOW RATES (cfs)
Model
(70 um)
(100 um)
(OK110)
150 um**
200 um**
HG 4 / HG 4i
0.8
1.1
0.9
1.3
1.6
HG 5
1.3
1.7
1.4
2.1
2.5
HG 6
1.8
2.6
2.0
3.0
3.6
HG 8
3.2
4.9
3.6
5.4
6.4
*60% Annual TSS Removal
**80% TSS Removal at WQF
For more information, please contact your local Hydroworks representative
21
22
PRECAST SLABS/BASES
PRECAST SLABS/BASES
Precon’s precast concrete slab and bases are engineered and designed for each individual
project and application. These products are highly customizable.
Slabs and bases, much like the rest of our product line, can also have many different types of
accessories cast in. These pieces can also be poured with almost any size of opening. On site, they
are easily installed, making them ideal for remote areas.
USES
1. CSP Bases
2. Pipeline Protection Slabs
3. Boat Ramp Slabs
4. Anti-Floatation Slabs
5. Compressor Bases
MECHANICAL
23
MECHANICAL
Precon offers complete packages for Valve Chambers and PRV’s, including the mechanical. All Precon’s Valve Chambers are engineered to meet Alberta’s CL-800 loading and all installed mechanical
components are pressure tested prior to shipping. Precon’s prepackaged mechanical structures are
one less thing for you to worry about.
USES
1. PRV’s
2. Backflow Valves Chambers
3. Flow Meters
4. Air Relief Valve Manholes
35
Sales Office
Main Office/Production Plant
Sales Office
#212, 160 Broadway Blvd
Sherwood Park, Alberta T8H 2A3
Phone: 780.464.0755
#2, CP Rail Road, Kipp Road
Coalhurst, Alberta
Phone: 403.382.4938
#333, 4615 112 Avenue SE
Calgary, Alberta T2C 5J3
Phone: 403.723.7225
Toll Free: 1.800.661.8020 · www.precon.ca