INSTALLATION INSTRUCTIONS
IT600
THERMALLY INSULATED HURRICANE RESISTANT STOREFRONT
These instructions assume that the installer has adequate trade knowledge in aluminum glazing systems and
aluminum entrance installation guidelines and procedures. Including frame leveling & squaring techniques,
surface cleaning for sealant application and perimeter seal waterproofing. The following instructions give product
specific installation information required to ensure proper product performance. In the event of adverse field
installation conditions, it is the responsibility of the installer to contact United States Aluminum Corporation for
recommendations and support prior to product installation.
200 Singleton Drive
Waxahachie, Texas 75165
T: 972 937-9651 F: 972 937-0405
Page 2
IT600 Installation Instructions
UNITED STATES ALUMINUM
IT600 Huricane Resistant Storefront System
TABLE OF CONTENTS
PAGE
GENERAL NOTES........................................................................................................................................................ 2 - 3
FABRICATION.............................................................................................................................................................. 4 - 7
ASSEMBLY................................................................................................................................................................. 8 - 10
INSTALLATION......................................................................................................................................................... 11 - 16
GLAZING .........................................................................................................................................................................17
THRESHOLD RAM .................................................................................................................................................. 18 - 19
INSTALLATION INSTRUCTIONS
GENERAL NOTES
HANDLING, STORAGE AND PROTECTION OF ALUMINUM
The following precautions are recommended to protect the material against damage. Following these precautions will
help ensure early acceptance of your products and workmanship.
A. HANDLE CAREFULLY.
AII aluminum materials at job site must be stored in a safe place well removed from possible damage by other
trades. Cardboard wrapped or paper interleaved materials must be kept dry.
B. CHECK ARRIVING MATERIALS.
Check for quantity and keep records of where various materials are stored.
C. KEEP MATERIAL AWAY FROM WATER, MUD AND SPRAY.
Prevent cement plaster or other materials from damaging the finish.
D. PROTECT THE MATERIALS AFTER ERECTION.
Protect erected frame with polyethylene or canvas splatter screen. Cement, plaster, terrazzo, other alkaline solu- tions and acid based materials used to clean masonry are harmful to the finish. lf any of these materials come in contact with the aluminum, immediately remove with water and mild soap.
United States Aluminum Corporation warrants its High Impact Glazing Systems to perform at the published values for air and water infiltration and structural
performance. Testing standards allow for unit inter layer a maximum rip size after impact and cycle testing. Though considered as successfully passing the test,
water infiltration can occur through the glazing material in such cases. United States Aluminum does not warrant any glazing materials resulting from impact from
wind borne debris and subsequent cycling under storm conditions.
When using this product, United States Aluminum Corporation recommends specifying a uniform overall glazing thickness of plus or minus .004” over the entire
area of the glazing unit. This must include edges and center of unit. It is critical to check the glazing unit prior to glazing to insure the proper thickness of the
inter layer. Glass must be two pieces of 1/4” thick, heat strengthened with a.030 pvb for DOD or .090” polycarbonate interlayer for hurricane requirements, 1/2”
air space and 1/4” thick, heat strengthened out board light.
Due to the diversity in state/provincial, local and federal laws and codes that govern the design and application of architectural products, it is the responsibility of
the individual architect, owner and installer to assure that products selected for use on projects comply with all applicable building codes and laws. United States
Aluminum exercises no control over the use or application of its products, glazing materials and operating hardware and assumes no responsibility thereof.
The rapidly changing technology within the architectural aluminum products industry demands that United States Aluminum reserve the right to revise, discontinue
or change any product line, specification or electronic media without prior written notice.
NOTE: Dimensions in parentheses ( ) are millimeters unless otherwise noted.
Other metric units shown in this manual are:
m - meter Kg - kilogram
Pa - pascal KPa - kilopascal
MPa - megapascal
February 2010
UNITED STATES ALUMINUM
IT600 Installation Instructions Page 3
GENERAL INSTALLATION NOTES
Recommended guidelines for all instAllAtions:
1.
REVIEW CONTRACT DOCUMENTS. Check shop drawings, installation instructions, architectural drawings and shipping lists to become thoroughly familiar with the project. The shop drawings take precedence and include spe-
cific details for the project. Note any field verified notes on the shop drawings prior to installing. The installation
instructions are of general nature and cover most conditions.
2. INSTALLATION. AII materials are to be installed plumb, level and true.
3. BENCH MARKS. AII work should start from bench marks and/or column lines as established by the architectural drawings and the general contractor with guaranteed accuracy. Working from these datum points and lines deter
mine: a) The plane of the wall in reference to offset lines provided on each floor.
b) The finish floor lines in reference to bench marks on the outer building columns.
c) Mullion spacing from both ends of masonry opening to prevent dimensional build-up of daylight opening.
4. STEEL ANCHORS. Steel anchors that weld to steel structure are normally line set before mullions are hung.
Outstanding leg of anchors must be at 90° to offset lines. Mullion space should be held to ±1/32” (0.8). Anchor clips vary per job conditions. Follow approved shop drawings for size and location of clips.
5. FIELD WELDING. AII field welding must be adequately shielded to avoid any splatter on glass or aluminum.
Results will be unsightly and/or structurally unsound. Advise general contractor and other trades accordingly. AII field welds of steel anchors must receive touch-up paint (zinc chromate) to avoid rust.
6. SURROUNDING CONDITIONS. Make certain that construction which will receive your materials is in accordance with the contract documents. lf not, notify the general contractor in writing and resolve differences before proceed- ing with work.
7. ISOLATION OF ALUMINUM. Aluminum to be placed in direct contact with uncured masonry or incompatible ma terials should be isolated with a heavy coat of zinc chromate or bituminous paint.
8. SEALANTS. Due to stringent guidelines, silicone sealant requirements for impact glazing systems must be:
Tremco Spectrum II or DOW 795 for all metal to metal and perimeter seals.
Tremco Proglaze SSG or DOW 995 for all glass to metal structural adhesion.
Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility,
cleaning/priming, tooling, adhesion, etc. It is the responsibility of the Glazing Contractor to submit a statement
from the sealant manufacturer indicating that glass and glazing material have been tested for compatibility and
adhesion with glazing sealants, and interpreting test results relative to material performance, including recom mendations for primers and substrate preparation required to obtain adhesion. The chemical compatibility of all
glazing materials and framing sealants with each other and with like materials used in glass fabrication must be
established. This is required on every project.
9.
FASTENING. Within the body of these instructions “fastening” means any method of securing one part to another or to adjacent materials. Only those fasteners used within the system are specified in these instructions. Due to the varying perimeter conditions and performance requirements perimeter and anchor fasteners are not specified in these instructions. For perimeter and anchor fasteners refer to the shop drawings or consult the fastener sup- plier.
10.
BUILDING CODES. Due to the diversity in state/provincial local and federal laws and codes that govern the design and application of architectural products it is the responsibility of the individual architect owner and installer to
assure that products selected for use on projects comply with all the applicable building codes and laws. United States Aluminum exercises no control over the use or application of its products glazing materials and operating hardware and assumes no responsibility thereof.
11.
EXPANSION JOlNTS. Expansion joints and perimeter seals shown in these instructions and in the shop drawings are shown at normal size. Actual dimensions may vary due to perimeter conditions and/or difference in metal tem-
perature between the time of fabrication and the time of installation. Gap between expansion members should be based on temperature at time of installation.
12.WATER HOSE TEST. As soon as a representative amount of the wall has been glazed (500 square feet or 46.5 m2) a water hose test should be conducted in accordance with AAMA 501.2 specifications to check the installation. On all jobs the hose test should be repeated every 500 square feet (46.5 m2) during the glazing operation.
13. COORDINATION WITH OTHER TRADES. Coordinate with the general contractor any sequence with other trades which offset curtain wall installation (i.e. fire proofing, back-up walls, partitions, ceilings, mechanical ducts, con
verters etc.).
14. CARE AND MAINTENANCE. Final cleaning of exposed aluminum surfaces should be done in accordance with
AAMA. 609.1 for anodized aluminum and 610.1 for painted aluminum.
February 2010
Page 4
IT600 Installation Instructions
UNITED STATES ALUMINUM
FABRICATION
CUT LENGTHS FOR FRAME FABRICATION
1.
­­­
2.
Measure rough opening to determine frame width and height dimension. Measure rough opening vertically in
multiple places to determine shortest dimension. Allow a maximum of 1/2” (12.7) caulk space at head and jambs.
See approved shop drawings for all other caulk space allowances. Shim subsill as required for leveling.
Subsill length is determined by entrance locations. Subsill butts to door jambs. Determine last bay
installation and allow 1/8” (3.2) additional length to subsill. See Detail A & B.
Cut members to length:
Subsill length without entrance = Frame Dimension plus 1/4” (6.4). Subsill must extend 1/8” outside last wall jamb to allow last bay installation.Subsill runs through. See Detail B.
Vertical length = Frame Dimension minus 5/8” (15.9).
Horizontal length = Day Light Opening.
Glass stop length = Day Light Opening minus 1/32” (0.8).
Door Opening
Frame dimension
(D.L.O.)
Head
(D.O.)
Frame Dimension minus ⁵⁄₈" (15.9)
Frame Dimension = Rough Opening minus Head caulk space
Daylight Opening
Wall jambs
Intermediate vertical
Door jambs
Door header
TH811 Threshold
Intermediate horizontals
Sill
Subsill
Frame Dimension minus ⁵⁄₈" (15.9)
Frame Dimension = Rough Opening minus Head caulk space
Distance from jamb edge
to D.O. plus ¹⁄₈" (3.2)
Distance from jamb
D.O. + 5" (127)
edge to D.O. plus ¹⁄₈" (3.2)
Daylight Opening
Head
(D.L.O.)
Wall jambs
Intermediate verticals
Intermediate horizontals
Sill
Subsill
Detail B
Frames without
entrance
Frame Dimension = Rough Opening minus Jamb caulk spaces
¹⁄₈"
(3.2)
¹⁄₈"
(3.2)
Frame Dimension plus ¹⁄₄" (6.4)
February 2010
Detail A
Frames with
entrance
Frame Dimension = Rough Opening minus Jamb caulk spaces
UNITED STATES ALUMINUM
IT600 Installation Instructions FABRICATION
Page 5
3. Fabricate subsills for weep holes as shown in Detail C.
4. Drill end dam attachment holes as shown in Detail C. NOTE: End dams occure at wall jambs only.
IG570
³⁄₈" dia. weep holes
(9.5) Typ.
6"
(152.4)
²⁷⁄₃₂"
(21.4)
CL of vertical mullion
6"
6"
(152.4)
(152.4)
Detail C
6"
(152.4)
IG570
⁵⁄₁₆"
(7.9)
³⁄₈" dia. weep holes
(9.5) Typ.
NOTE:
3/8" Dia. weep
holes must
penetrate both
walls of subsill.
3. Fabricate subsills for anchor holes. Detail D shows base hole patterns. Finial anchoring bolt types, spacings and fabrication are to be project determined and supersede these instructions. See note below.
WALL JAMB
INTERMEDIATE VERTICAL
2 ⁵⁄₈"
(66.7)
⁷⁄₁₆" (11.1)
dia. hole or
expansion slot
DOOR JAMB
⁷⁄₁₆" (11.1)
dia. pinning holes
⁷⁄₁₆" (11.1)
dia. pinning hole
4 ¹⁄₂"
(114.3)
2"
(50.8)
2 ¹⁄₂"
(63.5)
⁷⁄₁₆" (11.1) dia. holes equally
spaced 16" (406) Min.
2"
(DLO - 4")Number
(50.8)
of anchor spaces
Day Light Opening (DLO)
2"
(50.8)
⁷⁄₁₆" (11.1) dia. holes equally
spaced 16" (406) Min.
2"
2"
(DLO - 4")Number
(50.8) (50.8)
of anchor spaces
Day Light Opening (DLO)
2 ¹⁄₂"
(63.5)
2 ¹⁄₂"
(63.5)
Detail D
IMPORTANT NOTE:
Subsills exceeding 24’ in length must provide for thermal expansion. Pin fixed locations to direct expansion movement away from
entrance doors and wall jambs as shown in Detail E. Locations shown only illustrate anchor pattern types at each mullion and
does not show anchor locations required between mullion spans. (16” max. typical)
EXPANSION
MOVEMENT
FIXED
WALL
JAMB
VERT
MULL
VERT
MULL
EXPANSION
MOVEMENT
VERT
MULL
EXPANSION
MOVEMENT
EXP
JOINT
VERT
MULL
EXPANSION
MOVEMENT
EXP
JOINT
VERT
MULL
Single door with water resistant threshold.
(Subsill runs through)
VERT
MULL
EXP
JOINT
FIXED
VERT
MULL
FIXED
FIXED
DOOR
JAMB
DOOR
JAMB
DOOR
JAMB
EXPANSION
MOVEMENT
EXP
JOINT
Detail E
VERT
MULL
FIXED
DOOR
JAMB
FIXED
EXPANSION
MOVEMENT
VERT
MULL
VERT
MULL
EXP
JOINT
EXPANSION
MOVEMENT
VERT
MULL
Fastener Diameter plus
expansion joint size
Fastener Diameter
plus 1/16”
ANCHOR SLOT
February 2010
Page 6
IT600 Installation Instructions
UNITED STATES ALUMINUM
FABRICATION
5. Fabricate vertical members for horizontal attachment. Drill attachment and access holes as shown in Detail F & G.
NOTE: Details shown with deep pocket right orientation.
NOTE: Door frame members are sold pre-fabricated per project door shedule and approved shop drawings.
C
L
Vertical
filler
Align with top
of vertical
1¹⁄₂"
1¹⁄₂"
(38.1)
(38.1)
Jamb
Use these drill
ports for head
member.
Vertical
Align with top of
horizontal member.
2"
Use these drill
ports for horizontal
member.
3"
(76.2)
1"
(25.4)
(50.8)
¹⁄₄"
(6.4)
2"
(50.8)
1"
(25.4)
.228 dia.
hole (5.8)
(#1 drill)
(50.8)
INTERIOR
EXTERIOR
2"
2"
Equal spaces
16" maxamum
(50.8)
2"
⁷⁄₁₆" (11.1) dia. perimeter anchor holes
At Jambs only
(50.8)
¹⁄₄"
(6.4)
2"
(50.8)
2"
(50.8)
¹⁄₄"
Detail F
(6.4)
Align with bottom
of vertical
Use these drill
ports for sill
member.
Equal spaces
16" maxamum
Drill fixture
INTERMEDIATE VERTICAL
FABRICATION
Detail G
February 2010
UNITED STATES ALUMINUM
IT600 Installation Instructions FABRICATION
Page 7
8. Fabricate head and sill members for anchor and weep holes as shown in Detail H.
Optional for condensation.
Drill ¹⁄₄" (6.4) dia. weep hole
through both walls.
To Mullion Connection
To filler connection
1⁷⁄₃₂"
(30.9)
2¹⁄₂"
(63.5)
⁷⁄₁₆" (11.1) dia.
anchor holes
HEAD
Equal anchor hole spacing
2"
(50.8)
2"
(50.8)
16" (406.4) O.C. max
Center on head
SILL
.228" (5.8) dia. anchor
holes (#1 drill)
To Filler Connection
To Mullion connection
1"
(25.4)
1 ²¹⁄₃₂"
(42.1)
³⁄₈" (9.5) dia.
weep holes
Equal anchor hole spacing
2"
(50.8)
6"
(152.4)
16" (406.4) O.C. max
Center on sill
2"
(50.8)
6"
(152.4)
Detail H
1. Clean ends of subsills that are to receive end dams. Clean end dams, apply sealant and install to ends of subsill as shown in Detail I.
CRITICAL NOTE:
Clean all contact surfaces with
adequate solvent type and wipe
with a lint free cloth using the 3
cloth cleaning method.
EC870 End cap
BT870
Subsill
(2) ST173
#8 x ¹⁄₂" F.H.S.M.S.
Apply bed of
silicone prior to
assembly. Silicone
must have full coverage
of subsill intersection.
Detail I
February 2010
Page 8
IT600 Installation Instructions
UNITED STATES ALUMINUM
ASSEMBLY
2. Clean and apply Tremco Spectrum II or DOW 795 silicone sealant to ends of horizontals and thresholds. Attach horizontals to verticals using ST266 #12 x 1” H.W.H. Grade 5 screws. See Detail J. Clean excess sealant from exposed joints.
ST266
#12 x 1" H.W.H. SMS
(Typ)
Apply silicone sealant
Door header
Head member
Intermediate
horizontal
Air resistant
threshold
MS175
#12-24 x 1/4"
F.H. M.S.
Sill member
Threshold clip
ST266
#12 x 1" H.W.H. SMS
(Typ)
ST266
#12 x 1" H.W.H. SMS
(Typ)
Detail J
February 2010
Water resistant
threshold
UNITED STATES ALUMINUM
IT600 Installation Instructions ASSEMBLY
Page 9
3. Install water deflectors into vertical glass pockets at vertical/horizontal intersections as shown in Detail K. Install water deflectors into vertical member at head as shown in Detail L. Apply sealant as shown.
Remove one leg
for handing
FLIP
TO HAND
Apply sealant to
interior glass pocket
wall prior to installing
water deflector.
Making sure to fill
the spacer reglet.
Inject sealant
into reglet.
Seal joining pocket
after water deflector
is installed.
Inject sealant
into reglet.
Leave these two areas open
to allow water to drain down to
the subsill.
Detail K
Apply sealant to interior glass pocket
wall prior to installing water deflector.
Making sure to fill the spacer reglet as
shown in Detail K.
Thoroughly seal horizontal
to vertical joint
Place water deflector
into glass pocket and
seal all contact edges.
Inject sealant
into reglet.
Inject sealant
into reglet.
Detail L
February 2010
Page 10
IT600 Installation Instructions
UNITED STATES ALUMINUM
ASSEMBLY
4. Prior to installing closure plates to tops of mullions, modify closure plates as shown in Detail M.
Note: Modification not required at jamb members.
¹⁄₄"
Trim portion of exterior down spouts
from mullion closure plates.
Jamb closure plates do not require
this modification.
T
E OW
X A
T R
E
R D
IO S
R
Mullion contact surface
Trim shoud be cut flush with main plane
of plate to allow good seal with top of mullion.
Detail M
5. Clean closure plates and top cut surface of mullions & jambs.
6. Apply silicone sealant to top of vertical member and press closure plate into place. See Detail N.
T
E OW
X
T A
E R
R D
IO S
R
Detail N
February 2010
Closure plate
T
E OW
X
T A
E R
R D
IO S
R
Apply silicone sealant to top edge
of mullions and jamb members and
press closure plate firmly into place.
UNITED STATES ALUMINUM
IT600 Installation Instructions INSTALLATION
Page 11
7. Install steel reinforcement. Slide steel into mullion as shown in Detail O.
NOTE: Steel position is CRITICAL at sill to allow access for sealing of door jamb base shown on Detail Y page 15.
8. Match drill through holes in steel reinforcement into mullion with #26 bit (.147” dia.). See Detail O.
9. Attach steel to mullion with ST238 #10 x C\,” FH SMS. See Detail P.
Steel channel
reinforcement
Head
Mullion
Steel anchor
Match drill through
holes in steel channel
reinforcement into
mullion for attachment
screws.
Sill
2"
(50.8)
ST238
#10 x ³⁄₈" FH SMS
(TYP)
Threshold
Detail O
Detail P
February 2010
Page 12
IT600 Installation Instructions
UNITED STATES ALUMINUM
INSTALLATION
1. Place fabricated subsill into opening allowing for jamb shim space and door frame. Match drill anchor holes using subsill as template.
2. Remove subsill, clean substratum. Apply full bed of sealant across both ends and full length of interior subsill line. Run full bed of sealant across front area leaving a 3” gap at each end as shown in Detail Q.
Note: Shim subsill as required for leveling. Coordenate shim space dimension with vertical member cut lengths.
Door jamb anchor locations
require dual fasteners.
Also see Details D & E.
CRITICAL SEALS:
Apply full beds of sealant leaving
gaps for drainage as shown and
seal around all anchor holes.
Subsill end dam not
shown for clarity.
Detail Q
3. Replace subsill into opening and anchor to substratum using required fasteners as described in approved shop drawings. Seal over all fastener heads as shown in Detail R­.
Cover fastener
heads with sealant.
BT570
Detail R
4. Subsill must be spliced for runs longer than 24’ (731.5 cm). Apply ¾” (19.1) wide bond breaker tape across center of bottom side of splice sleeve as shown in Detail S.
Apply bond-breaker
tape to center, bottom
side of splice sleeve
prior to assembly.
Bottom
Detail S
February 2010
UNITED STATES ALUMINUM
IT600 Installation Instructions INSTALLATION
Page 13
5. Insert backer rod into rectangular voids of subsill ends and seal as shown in Detail T.
Insert backer rod
into space between
subsill ends and
apply silicone then
tool.
Cover unfastened edge
of splice sleeve with
bond breaker tape
Insert backer rod
into hollow and
fill with silicone.
Detail T
6. Attach one side of splice sleeve to subsill with ST206 #8 x ½” S.M.S. Apply bond breaker tape to unfastened end of splice sleeve as shown. Seal over tape extending sealant ¼” each side of tape edges as shown in Detail U. Seal all remaining sleeve edges as shown.
Seal entire perimeter of
splice sleeve with silicone.
CRITICAL DIMENSION
Completely cover
bond breaker tape
extending ¹⁄₄" on
each side.
Seal over screw head
⁵⁄₈"
(15.9)
Fill gap with
sealant.
Fasten one end of splice sleeve
with ST206 #8 x ¹⁄₂" P.H.S.M.S.screw
Detail U
7. Prior to installing first and last frame panels apply sealant to subsill end dam joints and screw tips. Tool sealant. Shim between end dam and building. See Detail V.
This is a critical seal
EC870
End Dam
Apply silicone to
all contact areas.
Detail V
February 2010
Page 14
IT600 Installation Instructions
UNITED STATES ALUMINUM
INSTALLATION
8. Seal ends of subsill that abutt door jambs as shown in Detail W.
Insert backer rod into
voids and fill with silicone.
After filling voids seal over exposed
edges and to finish floor.
Detail W
9. Prepairing for installation of frame panels. Door frame must be installed prior to side light panels.
See Detail X for erection sequence example.
DOOR FRAME
Insertion method
Erection order
Panel
1
Panel
3
Panel
3
2
Panel
Panel
4
5
DIRECTION OF WORK
Detail X
February 2010
Panel
6
Panel
6
UNITED STATES ALUMINUM
IT600 Installation Instructions INSTALLATION
Page 15
10. Seal base of all installed door frame panel jambs and joining subsill edges prior to sidelight installation.
See Detail Y.
Bed of sealant at base
of door jamb must be
tapered toward subsill
to direct water toward
weep holes.
Door jamb.
Left jamb shown
right jamb opposite.
Completely fill
bottom of door
jambs with silicone.
Seal all subsill to
door jamb joints.
TH821
Threshold
Plug and seal
at subsill end.
See Detail W.
Seal and tool
exterior and
interior door
jambs to structure.
WATER
Interior & Exterior subsill end plugs
(See Detail U on Page 13)
NOTE: These are CRITICAL seals. Sealant must form a water tight dam at base of door jamb.
Detail Y
11. Apply a continuous bead of Tremco Spectrum II or DOW 795 Silicone sealant to interior and exterior snap legs as shown in Detail Z.
Apply sealant full length
at interior and exterior
to mullion snap legs.
(Steel reinforcement not shown)
Detail Z
February 2010
Page 16
IT600 Installation Instructions
UNITED STATES ALUMINUM
INSTALLATION
12. Install assembled frame panels into opening starting at left jamb shimming for proper caulk spaces. Match drill through anchor holes in sill into subsill as shown in Detail AA. Attach sill to subsill with ST268 (#12 x 3/4” HWH SMS type B). Shim at anchor locations and fasten jamb and head member to building. Install next panels in left to right sequence anchoring each panel in place. Last bays and panels adjacent to installed door frame require “accordion” method to clear end dams and snap legs.
13. Seal over fastener heads at head members as shown in Detail AA.
Push frame to back
wall of subsill and
match drill .182 (4.6)
Dia. hole, #14 bit
through sill member
into subsill.
PUSH
Anchor sill members
with ST268 HWH SMS
Seal over bolt heads.
Subsill bolt heads must be
sealed prior to frame installation.
Detail AA
14. Install backer rod and apply silicone sealant to interior and exterior frame perimeter at head and jambs.
15. Inject a bead of sealant into exterior and interior reveals of subsill and sill members as shown in Detail BB.
Put this seal at interior and
exterior space between
subsill legs and framing.
Detail BB
February 2010
UNITED STATES ALUMINUM
IT600 Installation Instructions GLAZING
Page 17
16. Lace gaskets into door stops, header and threshold leaving 1/8” (3.2) extension past each end to insure a tight joint with connecting gaskets. Apply Tremco Spectrum II or DOW795 silicone sealant to door stop adaptor and door stop as shown on Detail CC.
17. Attach door stop adaptors with ST197 #8 x 3/8” PH SMS 1” form each end and 12” O.C. and snap on door stops. Seal gasket intersections at head and threshold with small joint sealant. See detail Detail CC.
ST197
#8 x 3/8 PH SMS
12" O.C.
IG146
Door stop
NP801
Gasket
BT847
Door stop
adaptor
Seal all door gasket
intersections with
small joint sealer.
Tremco
Spectrum II
or DOW795
Sealant
Threshold
Door Jamb
Detail CC
February 2010
Page 18
IT600 Installation Instructions
UNITED STATES ALUMINUM
FABRICATION / INSTALLATION
1. Clean glazing areas of frames that will come in contact with structural silicone.
2. Install spacer gaskets and setting blocks. Locate setting blocks at quarter points or as directed by approved shop drawings.
3. Clean surfaces of glass that will come in contact with structural silicone.
DO NOT ALLOW CLEANING SOLUTION TO COME IN CONTACT WITH LAMINATE AT EDGE OF GLASS.
4. Install glass as shown in Detail DD. Center glass in opening. It is recommended to mark edges of glass to guage proper glass bite. PROPER GLASS BITE OF 9/16” (14.3) ­­­IS CRITICAL.
5. Install glass stops and exterior gaskets.
3
4
1
2
5
Detail DD
6. Mask off aluminum at edge of glass pocket and mask glass 1/8” (3.2) from the edge of aluminum as shown in Detail EE.
7. Apply structural silicone, tool and remove tape. Use caution in removing tape to avoid marring tooled silicone.
Follow manufacturers recommendations for cure times.
It's critical that sealant
be injected full depth of
void for proper adhesion.
¹⁄₈" Min.
(3.2)
Tremco SSG
or DOW 995
Silicone
Tape
NP225 Exterior gasket
SP250 Silicone spacer
Detail EE
February 2010
⁹⁄₁₆"
(14.3)
UNITED STATES ALUMINUM
IT600 Installation Instructions Page 19
FABRICATION / INSTALLATION
ADA THRESHOLD RAMP FABRICATION LAYOUT
NOTE: Water resistant threshold and threshold rams are only available for single entrances.
Door frames with TH800 thresholds require ADA threshold ramps. The dimensions given are for reference only. Field
measuring will be required to achieve proper miter joint alignment. Special consideration will be required for unlevel
concrete conditions at entrance locations. Shimming under the small return end pieces may be required for proper leveling.
1. Cut pieces to length. See Detail FF.
2. Drill .221 (5.6) Dia. holes and countersink at .437 (11.1) Dia. X 82o for anchoring as shown. Anchor holes are shown with equal spacing and should not exceed 18” O.C.
D.O. + 70 ¹⁄₁₆" (1779.6)
D.O. + 54 ¹⁹⁄₃₂" (1386.7)
D.O. + 39 ³⁄₃₂" (993.0)
anchor at 7 equal spaces
5"
(127)
5"
anchor at 6 equal spaces
5"
(127)
2 ⁹⁄₁₆"
anchor at 5 equal spaces
5"
(127)
5 ¹⁄₁₆"
5"
(127)
2 ¹⁵⁄₃₂" (62.7)
(65.1)
5"
2 ¹⁵⁄₃₂"
(127)
2 ¹¹⁄₁₆" (68.3)
(62.7)
(128.6)
2" (50.8)
.178 (4.5)
Door Opening (D.O.)
26¹⁄₂" (673.1)
1¹⁄₂" (38.1)
2¹⁄₂"
1³⁄₄" (44.5)
(63.5)
5"
(196.9)
2 ¹⁵⁄₃₂"
(62.7)
(127)
12 ¹³⁄₁₆" (325.4)
(127)
7 ³⁄₄"
5"
(127)
2 ⁹⁄₁₆" (65.1)
(130.2)
2"
(50.8)
2 ⁹⁄₁₆"
anchor at 5 equal spaces
5"
5"
(127)
(127)
5¹⁄₈"
15 ¹⁄₂" (393.7)
41 ³⁄₁₆" (1046.2)
20 ⁹⁄₁₆" (522.3)
5"
(127)
(65.1)
5"
(127)
2 ⁹⁄₁₆"
5"
Detail FF
(127)
(65.1)
anchor at 6 equal spaces
D.O. + 44 ¹⁵⁄₃₂" (1129.5)
5"
(127)
D.O. + 59 ³¹⁄₃₂" (1523.2)
ADA Note:
Ramps for single doors must extend 24” (609.6) beyond outside edge of lock jamb for approch access.
Detail GG shows hinge right
layout with lock jamb to left.
Detail GG
24" (609.6) Min.
from edge of lock jamb
February 2010
Page 20
IT600 Installation Instructions
UNITED STATES ALUMINUM
FABRICATION / INSTALLATION
4. Notch hook and exterior end pieces to clear frame components as shown in Details HH and I I.
.178 (4.5)
Remove hook from exterior
TH801 outside of door opening.
See Detail DD on page 18 for notching
locations.
Detail HH
Notch area
Dimensions are for reference and
may vary per actual job conditions.
Field measure and notch as required.
IG470
7 ¹⁄₁₆" (179.4)
TH803
⁷⁄₃₂" (5.6)
TH802
Detail I I
February 2010