Introduction to OMNISEC system
Transcription
Introduction to OMNISEC system
03/05/2016 Introduction to OMNISEC system 1 03/05/2016 OMNISEC Separations module OMNISEC RESOLVE Sample characterization OMNISEC REVEAL Introduction to OMNISEC RESOLVE 2 03/05/2016 OMNISEC RESOLVE › › OMNISEC RESOLVE is the separations module Integration of all separations components makes OMNISEC RESOLVE a complete SEC separation solution Degasser › › › › Degassing removes dissolved gases for better baseline stability and pump performance Low-volume (2 x 1 mL channels), high efficiency degasser Faster solvent exchange and quicker equilibration Better baseline stability and reduced instrument down-time during solvent exchange 3 03/05/2016 SEC pump › Low pulsation isocratic pump ideal for SEC separations Better resolution More repeatable separations › Integrated seal back-flushing for reduced seal wear Reduced maintenance requirement › Self-priming pump means no need to draw mobile phase with a needle, simply open the purge valve Autosampler › › Injections from vials or 96-well microtiter plates Temperature controlled (4-60°C) plate holder › µl pickup mode › Zero injection overhead No sample waste during injections Partial loop mode › Preserve protein samples from aggregation Maintain polymer dissolution Improve injection of high viscosity samples (e.g. in DMSO) 45 µl sample overhead Improved injection accuracy and precision Post injection washing means undetectable carry-over 4 03/05/2016 Column oven › Store up to 6 analytical SEC columns or 1 GE Tricorn 300/10 (e.g. Superdex) column › Temperature control from 20 to 65°C OMNISEC RESOLVE design › › › › Complete separations module including columns allows detector to be plug and play Two connections to OMNISEC REVEAL minimizes setup complexity Space for solvent and waste bottles on top Simply connect to OMNISEC REVEAL to set up 5 03/05/2016 Separation module – OMINSEC RESOLVE › › › › › › › › Injection reproducibility 0.2% for maximum result quality Zero overhead autosampler (vs 50µl in GPCmax) Temperature controlled autosampler. Cooling to protect samples from degradation (e.g proteins) or warming reduce sample viscosity (e.g. samples in DMSO) Sampling from vials or from 96/384 well-plates Improved efficiency and smaller volume degasser (2ml vs 30 in GPCmax – quicker solvent changeover/stabilization) New pump with integral seal washing Large capacity column oven with highly effective temperature control Room for a vertical GE column in the oven Introduction to OMNISEC REVEAL 6 03/05/2016 OMNISEC REVEAL technology › OMNISEC REVEAL is the integrated detector module Refractive index › › › Refractive index Measure sample concentration of almost any sample Measure dn/dc OMNISEC contains a robust RI cell placing it at front of detector series UV/Vis PDA Minimizes band broadening (dispersion) between all detectors caused by RI temperature equilibration tubing › Wavelength matched with LS detector (640 nm) RALS/LALS Intrinsic viscosity 7 03/05/2016 UV/Vis PDA Refractive index UV/Vis PDA RALS/LALS Intrinsic viscosity Light scattering › › Refractive index The LS detector is a RALS/LALS detector The laser light is now fibre-delivered Better focussing of the laser light More power to the cell › 50 mW laser › Sensitivity improved UV/Vis PDA RALS/LALS Intrinsic viscosity 8 03/05/2016 Light Scattering › › Refractive index Molecular weight quantification at 100 ng! Polystyrene 105 KDa in THF, 0.01 mg/mL, 10 µL injection Parameter Retention volume (mL) Mn (Da) Mw (Da) Mz (Da) PD (Mw/Mn) 100 ng PS105 8.02 105,470 108,180 110,570 1.026 UV/Vis PDA RALS/LALS Intrinsic viscosity OMNISEC REVEAL light scattering sensitivity - Protein › › › Molecular weight quantification at 100 ng! BSA 66 KDa in PBS 0.05 mg/ml, 2 µL injection Accurate calculation of molecular weight RV (mL) Mn (g/mol) Mw (g/mol) Mz (g/mol) Mw/Mn 9.083 63,800 65,070 66,290 1.02 9 03/05/2016 Viscometer technology › Refractive index The exchangeable bridge can be removed and replaced in just 10 minutes +IP SEC IN UV/Vis PDA - DP + RALS/LALS OUT Intrinsic viscosity Viscometer › › Refractive index Automated bridge balancing mechanism As the capillary moves within its sleeve, the resistance changes altering the bridge balance UV/Vis PDA RALS/LALS Intrinsic viscosity 10 03/05/2016 Viscometer › Refractive index The software automatically searches for the zero position Viscometer signal UV/Vis PDA 0 RALS/LALS Intrinsic viscosity OMNISEC REVEAL user-focussed design › OMNISEC REVEAL is the integrated detector module › Developed with the user and servicing in mind 11 03/05/2016 OMNISEC REVEAL design › › The user can only interact with those parts that may need maintenance Quick and easy replacement of: UV bulb Viscometer bridge Delay columns Detector module – OMNISEC REVEAL › › › › › Redesigned RALS/LALS with significant sensitivity improvements New viscometer design (self-balancing bridge with userexchangeable capillaries) Improved RI, including change of position in detector module, and excellent sensitivity Completely new UV-diode array (full UV/Vis range) Temperature control of all detectors and inter-detector tubing (20 to 65°C) 12 03/05/2016 Systems or detectors Detector-only or complete system › Having a complete OMNISEC system means: A complete solution from a single supplier designed and manufactured to work together A single software package for control of the hardware, data acquisition and data analysis A single point of contact for service and support issues 13 03/05/2016 Detector-only or complete system › Taking a detector-only option means: Saving money by upgrading an existing system to advanced detection Using an established method and getting additional information 3rd party SEC system OMNISEC system AQUEOUS APPLICATIONS 14 03/05/2016 Conditions for Aqueous analysis › › › › Eluent: 0.05 M sodium suphate Flow rate: 1.0 mL/min Columns: 2 x A6000M Temperatures °C: Autosampler: Columns: 35 Detectors: 35 10 PEO standards - RI and RALS 196 to 992,000 Da 992,000 Da 196 Da 15 03/05/2016 PEO 196 Da by Triple Detection ! › › PEO 196 Da 3.9 mg/ml, 100 µl injection Low molecular weight examples Low dn/dc examples 16 03/05/2016 Triple Chromatogram of Bisphenol A (MW = 228) › › Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 3 mg/mL Flow Rate: dn/dc: 1 mL/min 0.195 Example Triple Chromatogram of Polypropylene Glycols › › Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 6 mg/mL Flow Rate: dn/dc: 1 mL/min 0.0454 17 03/05/2016 Summary of Molecular values of Polypropylene Glycols Samples › › Mw Mn PDI IV dn/dc % Recovery PPG-1A 2,806 2,487 1.13 0.062 0.0454 100.1 PPG-1B 2,644 2,061 1.28 0.061 0.0454 101.6 AVE 2,725 2,274 1.21 0.061 0.0454 100.9 PPG-2A 2,831 2,691 1.05 0.067 0.0454 99.2 PPG-2B 2,753 2,394 1.15 0.061 0.0454 100.1 AVE 2,792 2,543 1.10 0.064 0.0454 99.6 PPG-3A 2,789 2,717 1.03 0.062 0.0454 99.5 PPG-3B 3,217 2,897 1.11 0.071 0.0454 99.4 AVE 3,003 2,807 1.07 0.067 0.0454 99.4 Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 6 mg/mL Flow Rate: dn/dc: 1 mL/min 0.0454 Triple Chromatogram of Polycaprolactone A (Mw = 1,800) › › Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 8 mg/mL Flow Rate: dn/dc: 1 mL/min 0.06 18 03/05/2016 Triple Chromatogram of Polycaprolactone B (Mw = 1,600) › › Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 5 mg/mL Flow Rate: dn/dc: 1 mL/min 0.06 Example Triple Chromatogram of Silicone Oils (Mw = 44,000) › › Mobile Phase: THF Temperature: 30C Columns: Injections: 2 X T2500 100 uL of 5 mg/mL Flow Rate: dn/dc: 1 mL/min 0.029 19 03/05/2016 OMNISEC REVEAL - summary Thanks for listening 20