IMR E VIRO ME TAL EQUIPME T, I C. CATALOG

Transcription

IMR E VIRO ME TAL EQUIPME T, I C. CATALOG
IMR EVIROMETAL
EQUIPMET, IC.
CATALOG
IMR Environmental Equipment Inc.
3634 Central Ave. ST. Petersburg, FL 33711 Phone: 727-328-2818 Fax: 727-328-2826
Web: www.imrusa.com E-mail: [email protected]
Environmental Equipment, Inc
COMBUSTION GAS ANALYZERS - PRODUCT RANGE
A new standard in measuring equipment
IMR 1000
IMR 1400
IMR 2800
IMR 1000 1-4
X
X
X
O
X
X
IMR 1050X
X
X
X
X
X
IMR 1050X-NO
X
X
X
X
X
X
IMR 1400 C/CP
X
X O X O O S O S
S O X
IMR 1400 P
X
X O X O
X
X
IMR 1400 PL
X
X O X O X
S
X
X
IMR 1400 PS
X
X O X O X
S
X
S
S
X
X
IMR 1400 IR
X
X
X O
O
O X
X
IMR 1440 FL/COFL
X
X O X
O
O X
IMR 2000 P
X
X
X O X O X
S
S
X
X
IMR 2800 P
X
X
X O X
X
X
S
S
X
X
IMR 2800 A\IR
X
X
X
X
S
X
S
X O X
IMR 5000
O O
O O O O O O O O
IMR 400/500
DA-75
X = Standard Feature, O = Optional Feature, S = can switch for another sensor
DA-75
O
X
X
X
O
X
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Dust
Printer
Dryer
Losses
Ex. Air
Efficiency
Soot
Temp
Draft
HC
H2S
SO2
NO2
NO
CO2-Measured
CO2-Calc
CO -High
CO
O2
For the continuous and simultaneous measurement of air temperature/ flue-gas temperature / O2 / CO / CO2 / SO2 / NO / NO2 / H2S / HC / CH4 / H2 / NH3 /
O3 / HCl / HCN / Cl2 / losses / efficiency / excess air / draft / soot
Additional gases available upon request
AUTOMATIC CALIBRATION - SELF-CHECK - EASE OF OPERATION - USEABLE FOR ALL FUELS
MEASURING INSTRUMENTS FOR MANY INDUSTRIAL APPLICATIONS
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
IMR 5000
X
X
IMR 1400
IMR 400
IMR 5000

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
MEASURING INSTRUMENTS
THERMOMETERS
•
•
•
Thermocouples: Type J, K, T, E
Range: up to 1370°C
Thermistors
Range: up to 300°C
Infrared
Range: up to 420°C
DT301/DT302/DT304
INF200
DTK2
RLD10
CD200
LEAK DETECTORS
•
•
•
•
Combustible Gases (HC)
Halogen refrigerants
Visual and audible alarm
Flexible probe, length 45cm
CD100A
ELECTRONIC MANOMETER
•
•
ANEMOMETER
Single or Dual Input
Range: +/- 150mbar
EM200
•
•
•
Temperature
Air velocity
Min/Max/AVG
•
•
•
Temperature
Type K, J, E, T
Up to 4 channels
DAFM3
DATA LOGGERS
•
•
•
Multiple Inputs
Able to log and output data
Up to 18 channels
SDU5000
TX 450
AMBIENT AIR DETECTORS
•
•
Multiple Gases O2, CO, H2S,
CH4
High and low alarms
•
Single Gas each
•
CH4, H2, H2S, CO, O2,
C3H8, C2H5OH, NH3,CL2, SO2
•
High and low alarms
IX616
RPM Meter
•
•
•
•
•
IX170
Soot Meter
Tachometer: 180-10,000 RPM
DC: 200mV to 1000V
AC: 200V to 750V
Ohms: 200 to 2M
Transistor: PNP and NPN
•
•
•
Measures the soot number
from 0.0 to 9.9
More reliable than a paper scale
Approximately 100,000
measurements on one set of batteries
RPM METER
IMR® Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPAY - MADE I USA © Copyright IMR Environmental Equipment, Inc.
Soot Meter
Environmental Equipment, Inc.
IMR 5000
IMR 5000
Continuous Flue Gas Monitoring System
•
•
•
•
•
•
The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas
monitoring applications.
The IMR 5000 is a stand-alone analyzer that works automatically. The rugged wall mounted enclosure meets NEMA type 4X
(IP65) standards.
The modular approach of the IMR 5000 allows one or more gases (up to 12 gases) to be measure simultaneously.
The IMR 5000 uses the latest sensor technology from electro-chemical sensors up to NDIR benches.
The IMR 5000 can be build to customer specifications
Analog 4 – 20mA or 0 – 20mA, RS232, Ethernet, RS485 are supported by the IMR 5000
APPLICATIO$S
•
•
•
•
•
•
•
Page 1 of 10
Boiler / Burners
Turbines
Engines
Incinerators
Process Control
Landfills
Cogeneration plants
Environmental Equipment, Inc.
IMR 5000
IMR 5000 Configuration
O2
8
Page 2 of 10
Environmental Equipment, Inc.
IMR 5000
(1) Gas Probe / Flange / Stainless Steel Filter
Probe length: 750mm
(2) 1.5 meters heated hose between Gas Probe and IMR 400 (length can vary according to customer’s specifications)
(3) 115VAC/230VAC Pump
(4) IMR 400 Including gas dryer inside
IP or Nema Rating
(5) Silicon Hose between IMR 400 and IMR 5000 (5 meters included)
(6) IMR 5000(flue gas measuring unit)
1. Data Logger (SD5000)
2. Sensor(s)
3. 4 – 20mA or 0 – 20mA Output
4. RS-232 Output (Optional)
5. RS-485 Output (Optional)
6. Communication through Ethernet
7. Circuit protection (2Amps)
8. IP64 or up to Nema 4X
9. Capable of working between temperatures of -10 and 50°C
10. Gas Temperature 0 - 1200°C
11. Display
12. Storage Media (SD card 1G)
13. 115VAC/ 230VAC 60Hz/50Hz
(7) 24VDC Pump
(8) Flue Gas Control (Optional)
(9) Temperature Probe (0 - 1200°C ) (Optional)
Page 3 of 10
Environmental Equipment, Inc.
IMR 5000
IMR 5000 I$TER$AL CO$FIGURATIO$
4 – 20mA or 0 – 20mA
output card
Temperature Probe
IMR 400
CH4
SO2
NOx
O2
ON
CO
MULITPLE STACK CO$FIGURATIO$
Timer
H2 S
Solenoids
24VD Power Supply
PUMP 24VDC
24VDC Power Supply
Page 4 of 10
5VDC Power Supply
OFF
Environmental Equipment, Inc.
IMR 5000
TECH$ICAL DATA
Function Process
The Internal gas conditioning unit (peltier cooler or permeation dryer)
dries and conditions the gas. The conditioned flue-gas is then analyzed
by the individual sensors (NDIR or Electrochemical). Processing unit
inside the IMR 5000 process this information and display it on its
5.7inch screen and relays the information to a monitoring computer
provide by customer. Thanks to the software application installed in the
monitoring unit, the customer is able to monitor this data.
Gas Dryer
• Permeation Dryer
• Heated hose 1,5 meters (Thermostat set for 140OC)
• Filter system, Stainless Steal housing
• Gas Probe 750 mm
• Flange 100 mm(4”)
• Gas pump
• IP or Nema rating enclosures (Varies according to
specifications)
Page 5 of 10
Analyzer
• Data Logger
• SDU5000
• Sensor(s)
• 4 – 20mA or 0 – 20mA
• RS-232 Output (Optional)
• RS-485 Output (Optional)
• Communication through Ethernet
• Circuit protection (2Amps)
• Storage Media (SD card 1G)
• IP or Nema rating enclosures (Varies according to specifications)
• Capable of working between temperature of -10 and 50oC
• Gas Temperature 0 – 1200oC
• 115VAC / 230VAC 60Hz/50Hz
Environmental Equipment, Inc.
IMR 5000
SDU5000
Aspects
• 6.4"Color TFT LCD with 640X480 pixels resolution
• The High Flexibility :
1. User configurable I / O
2. Expandable modular architecture
3. Flexible screen configuration
• User-Friendly:
1. Soft keys coupled with interactive dialog
2. Simplify setup & operation procedures
3. Easy - to - access function keys
• Various Display Formats:
1. Vertical trend , Horizontal trend Bar Graph, Numerical or
mixed
• Fast sampling rate (200msec for all channels)
• Programmable alarm and messages
• Infrared detector that allows LCD to shut off automatically to
prolong LCD life and power
Graph and Bar Display
Page 6 of 10
Main Screen Display
Environmental Equipment, Inc.
IMR 5000
GAS RA$GES OPTIO$S*
CO (Carbon Monoxide)
Range:
0 – 50,000ppm
Resolution:
10ppm
O2 (Oxygen)
Range:
Resolution:
SO2 (Sulfur Dioxide)
Range:
0 – 2000ppm
Resolution:
1ppm
CH4(Methane) $DIR
Range:
0 – 100%LEL
Resolution:
0.1%
$O ($itric Oxide)
Range:
0 – 2,000ppm
Resolution:
1ppm
H2S (Hydrogen Sulfide)
Range:
0 – 200ppm
Resolution:
0.1ppm
Temp (Optional)
Range:
0 – 1200oC /
0 – 2192oF
Resolution:
1 oC / 1 oF
Particles System (Optional)
Range:
0 – 999,999ppm
Resolution:
1ppm
$O2 ($itrogen Dioxide)
Range:
0 – 2,000ppm
Resolution:
1ppm
HCl (Hydrogen Chloride)
Range:
0 – 100ppm
Resolution:
0.1ppm
HF (Hydrogen Fluoride)
Range:
0 – 100ppm
Resolution:
0.1ppm
$H3 (Ammonia)
Range:
0 – 100ppm
Resolution:
0.1ppm
HC (Hydro Carbon)
Range:
0 – 100% LEL
Resolution:
0.1 %
CL2 (Chlorine)
Range:
0 – 100ppm
Resolution:
0.1ppm
O3 (Ozone)
Range:
Resolution:
$2O ($itrogen Oxide)
Range:
0 – 1,000ppm
Resolution:
1ppm
0 – 21%
0.1%
0 – 100ppm
0.1ppm
ACURACY
Measurement Range: = 100%
0 – 20% = +/-5% of measure
20 -100% = +/-1% of measure range
CALCULATE PARAMETERS (Optional)
CO2 (Carbon Dioxide)
Range:
0 – 25%
(CO2 can also be measure upon request)
*Other gases and ranges upon request
Page 7 of 10
Efficiency (ETA)
Range:
0 – 100%
Excess Air (Lambda)
Range:
0 – 100%
Losses (QA)
Range:
0 – 100%
Environmental Equipment, Inc.
IMR 5000
Stack 1
Stack 4
Page 8 of 10
Stack 3
Stack 2
MULITPLE STACK CO$FIGURATIO$ (2 to 4 Stacks)
Environmental Equipment, Inc.
IMR 5000
MULTIPLE STACKS I$TER$AL CO$FIGURATIO$ (2 to 4 Stacks)
Gases and stack configuration will depend on customer’s requirements
Page 9 of 10
Environmental Equipment, Inc.
IMR 5000
OBSERVER II (Optional)
Every IMR 5000 is shipped with a copy of OBSERVER I,
which has the basic function for calibration and
configuration of IMR 5000 Instrument.
OBSERVER II includes the same functions as OBSERVER
I, however OBSERVER II allows the real time
monitoring/observation, calibration and configuration of
IMR 5000 unit. OBSERVER II is availabe upon request.
LTIPLE STACKS I$TER$AL CO$FIGURATIO$ (2 to 4 Stacks)
MULTIPLE STACKS I$TER$AL CO$FIGURATIO$ (2 to 4 Stacks)
IMR Environmental Equipment, Inc.
3634 Central Ave.
St. Petersburg, Fl 33711
Phone: 1-800-RING-IMR
E-mail: [email protected]
Website: www.imrusa.com
Page 10 of 10

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
THE ALL NEW
IMR 2800 P Series
IMR 2800 P
NEW FEATURES OF THE 2800P-Series
Latest sensor technology for a more accurate
measurement and longer life time
Improved interior design for easier service
and better unit protection
Continuously and simultaneously measuring
up to 18 parameters
Larger display for a better reading
Applications: Boilers, Burners, Engines,
Turbines, Cars, Trucks, Plants, Chemical
Industries, Steel Plants, Refineries, etc
STANDARD FEATURES
Portable combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
NO2
Nitrogen dioxide
CO
Carbon Monoxide
SO2
Sulfur dioxide
NO
Nitric oxide
TG
Flue-gas temperature
TA
Ambient Air temperature
Calculation of following parameters
Losses / Efficiency
NOx
Nitrogen Oxides
Excess Air / Lambda
CO2
Carbon Dioxide
23 Fuels are programmed – 4 fuels are programmable
Automatic zero calibration
Integrated self-check program
Simultaneous display parameters on the illuminated display
Printer with programmable print out cycles
Standard deviation and average value calculation
Draft measurement with optional upgrade for differential draft and velocity measured with a Pitot tube
3
3
Unit selection :
ppm – mg/Nm – mg/Nm (ref O2)
Gas sampling probe E – length 0.8 ft (250mm), hose 8 ft (2.5m)
Rechargeable battery with charger
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
♦
HCl, N2O, CL2, H2, NH3, HC or H2S measurement
CO2, CH4/HC and N2O NDIR sensors available
Speed RPM
Prepared for high temperature measurement
(up to 2732 °F / 1500 °C)
♦
♦
♦
♦
Gas sampling probes with different lengths
Soot measurement
Gas Flow m/s
Additional Instruments: RPM Meter, Soot Meter
THE PRIDE OF THE COMPAY - MADE I USA -

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
THE ALL NEW
IMR 2800 P
PARAMETER
PRINCIPLE
RESOLUTION
ACCURACY
RANGE**
O2
CO
Electro-chemical cell
Electro-chemical cell
NDIR
0.1 Vol.%
1 ppm
0.001 Vol.%
± 0.2 Vol. %
Z
0-20.9 Vol. %
0-2000/4000ppm
0-10/20 Vol.%
NO Nitric oxide
NO2 Nitrogen dioxide
SO2 Sulfur dioxide
H2S Hydrogen Sulfide
HC/CH4 Hydrocarbons
TG Flue gas temperature
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Pellistor or NDIR
NiCr-Ni thermocouple
1 ppm
1 ppm
1 ppm
1 ppm
0.1 %
1K
Z
Z
Z
Z
Z
±2%
TA
Semiconductor
1K
± 0.2 K
Solid state
Calculation
Calculation
NDIR
Electro-chemical
NDIR
Electro-chemical
Electro-chemical
Electro-chemical
Calculation
Calculation
Filter paper method
Solid state
Solid state
0.01 hPa
1 ppm
0.1 Vol.%
0.01 Vol.%
1 ppm
0.001 Vol. %
1 ppm
1 ppm
1 ppm
0.1 %
0.1 %
±2%
Z
± 0.2 Vol. %
± 0.2 Vol. %
Z
Z
Z
Z
Z
± 0.1 %
± 0.1 %
0.01 m/s
100 RPM
±2%
±2%
0-2000 ppm
0- 100 ppm
0-4000 ppm
0- 200 ppm
0-100% LEL
-4°F - 2192°F
0°C - 1200°C
-4°F / 248°F
0°C - 120°C
±40 hPa
0-NOx max
0- CO2 max
0-20 Vol. %
0-1000/5000 ppm
0-1 Vol. %
0-200 ppm
0-5000 ppm
0-10000 ppm
0-99.9 %
1.0-9.99
0-9
0-80 m/s
180-10000 RPM
Oxygen
Carbon monoxide
Air temperature
P
Draft
NOx Nitrogen oxides
CO2 Carbon dioxide
CO2 Carbon dioxide
NH3 Ammonia
N2O Nitrous Oxide
HCl Hydrogen Chloride
Cl2 Chlorine
H2 Hydrogen
Losses / Efficiency
Excess Air / Lambda
Soot
Velocity with Pitot tube
RPM Meter
** Different/customized ranges available.
STANDARD
DIR
Optional
Equipped with a maximum of 8 gas sensors
Z = 0 - 20 % of whole measurement range ± 5 %
21 - 100 % of whole measurement range ± 1 % of displayed measurement
MODEL
IMR 2800 P
Dimensions (inch): 15 x 6.5 x 12.4
(375mm x 165mm x 300mm)
Weight: 17 lbs. (8 kg)
PART-NO.
IMR 28000
Represented by:
OPTIONAL ITEM
Soot Meter
RPM Meter
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice
THE PRIDE OF THE COMPAY - MADE I USA -
PART-NO.
Soot Meter
RPM Meter

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
AUTOMOTIVE FLUE GAS ANALYZER
IMR 2800 A
THE ALL NEW
IMR 2800 A Series
NEW FEATURES OF THE 2800A-Series
Latest sensor technology for a more accurate
measurement and longer life time
Improved interior design for easier service
and better unit protection
Continuously and simultaneously measuring
up to 18 parameters
Larger display for a better reading
Applications: Boilers, Burners, Engines,
Turbines, Cars, Trucks, Plants, Chemical
Industries, Steel Plants, Refineries, etc
STANDARD FEATURES
Portable combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
NO2
Nitrogen dioxide
CO
Carbon Monoxide
SO2
Sulfur dioxide
NO
Nitric oxide
TG
Flue-gas temperature
TA
Ambient Air temperature
Calculation of following parameters
Losses / Efficiency
NOx
Nitrogen Oxides
Excess Air / Lambda
CO2
Carbon Dioxide
Automatic zero calibration
Integrated self-check program
Simultaneous display parameters on the illuminated display
Printer with programmable print out cycles
Standard deviation and average value calculation
Draft measurement with optional upgrade for differential draft and velocity measured with a Pitot tube
3
3
Unit selection :
ppm – mg/Nm – mg/Nm (ref O2)
Gas sampling probe E – length 0.8 ft (250mm), hose 8 ft (2.5m)
Rechargeable battery with charger
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
♦
HCl, N2O, CL2, H2, NH3, HC or H2S measurement
CO2, CH4/HC and N2O NDIR sensors available
Speed RPM
Prepared for high temperature measurement
(up to 2732 °F / 1500 °C)
♦
♦
♦
♦
Gas sampling probes with different lengths
Soot measurement
Gas Flow m/s
Additional Instruments: RPM Meter, Soot Meter
THE PRIDE OF THE COMPAY - MADE I USA -

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
THE ALL NEW
IMR 2800 A
PARAMETER
PRINCIPLE
RESOLUTION
ACCURACY
RANGE**
O2
Oxygen
CO Carbon monoxide
CO2 Carbon dioxide
HC/CH4 Hydrocarbons
NO Nitric oxide
NO2 Nitrogen dioxide
SO2 Sulfur dioxide
H2S Hydrogen Sulfide
TG Flue gas temperature
Electro-chemical cell
NDIR
NDIR
NDIR
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
NiCr-Ni thermocouple
0.1 Vol.%
0.001 Vol.%
0.01 Vol.%
0.1 %
1 ppm
1 ppm
1 ppm
1 ppm
1K
± 0.2 Vol. %
Z
± 0.2 Vol. %
Z
Z
Z
Z
Z
±2%
TA
Semiconductor
1K
± 0.2 K
Solid state
Calculation
Electro-chemical
NDIR
Electro-chemical
Electro-chemical
Electro-chemical
Calculation
Calculation
Filter paper method
Solid state
Solid state
0.01 hPa
1 ppm
1 ppm
0.001 Vol. %
1 ppm
1 ppm
1 ppm
0.1 %
0.1 %
±2%
Z
Z
Z
Z
Z
Z
± 0.1 %
± 0.1 %
0.01 m/s
100 RPM
±2%
±2%
0-20.9 Vol. %
0-10/20 Vol.%
0-20 Vol. %
0-100% LEL
0-2000 ppm
0- 100 ppm
0-4000 ppm
0- 200 ppm
-4°F - 2192°F
0°C - 1200°C
-4°F / 248°F
0°C - 120°C
±40 hPa
0-NOx max
0-1000/5000 ppm
0-1 Vol. %
0-200 ppm
0-5000 ppm
0-10000 ppm
0-99.9 %
1.0-9.99
0-9
0-80 m/s
180-10000 RPM
Air temperature
P
Draft
NOx Nitrogen oxides
NH3 Ammonia
N2O Nitrous Oxide
HCl Hydrogen Chloride
Cl2 Chlorine
H2 Hydrogen
Losses / Efficiency
Excess Air / Lambda
Soot
Velocity with Pitot tube
RPM Meter
** Different/customized ranges available.
STANDARD
Equipped with a maximum of 8 gas sensors
Z = 0 - 20 % of whole measurement range ± 5 %
21 - 100 % of whole measurement range ± 1 % of displayed measurement
MODEL
IMR 2800-A
Dimensions (inch): 15 x 6.5 x 12.4
(375mm x 165mm x 300mm)
Weight: 17 lbs. (8 kg)
PART-NO.
IMR 28100
Represented by:
OPTIONAL ITEM
Soot Meter
RPM Meter
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice
THE PRIDE OF THE COMPAY - MADE I USA -
PART-NO.
Soot Meter
RPM Meter

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
IR - FLUE GAS ANALYZER
THE ALL NEW
IMR 2800-IR Series
IMR 2800-IR
NEW FEATURES OF THE 2800IR-Series
Latest sensor technology for a more accurate
measurement and longer life time
Improved interior design for easier service
and better unit protection
Continuously and simultaneously measuring
up to 18 parameters
Larger display for a better reading
Applications: Boilers, Burners, Engines,
Turbines, Cars, Trucks, Plants, Chemical
Industries, Steel Plants, Refineries, etc
STANDARD FEATURES
Portable combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
NO2
Nitrogen dioxide
CO
Carbon Monoxide
SO2
Sulfur dioxide
NO
Nitric oxide
TG
Flue-gas temperature
TA
Ambient Air temperature
Calculation of following parameters
Losses / Efficiency
NOx
Nitrogen Oxides
Excess Air / Lambda
CO2
Carbon Dioxide
Automatic zero calibration
Integrated self-check program
Simultaneous display parameters on the illuminated display
Printer with programmable print out cycles
Standard deviation and average value calculation
Draft measurement with optional upgrade for differential draft and velocity measured with a Pitot tube
3
3
Unit selection :
ppm – mg/Nm – mg/Nm (ref O2)
Gas sampling probe E – length 0.8 ft (250mm), hose 8 ft (2.5m)
Rechargeable battery with charger
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
♦
HCl, N2O, CL2, H2, NH3, HC or H2S measurement
CO2, CH4/HC and N2O NDIR sensors available
Speed RPM
Prepared for high temperature measurement
(up to 2732 °F / 1500 °C)
♦
♦
♦
♦
Gas sampling probes with different lengths
Soot measurement
Gas Flow m/s
Additional Instruments: RPM Meter, Soot Meter
THE PRIDE OF THE COMPAY - MADE I USA -

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
THE ALL NEW
IMR 2800 IR
PARAMETER
PRINCIPLE
RESOLUTION
ACCURACY
RANGE**
O2
Oxygen
CO Carbon monoxide
CO2 Carbon dioxide
HC/CH4 Hydrocarbons
NO Nitric oxide
NO2 Nitrogen dioxide
SO2 Sulfur dioxide
H2S Hydrogen Sulfide
TG Flue gas temperature
Electro-chemical cell
NDIR
NDIR
NDIR
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
NiCr-Ni thermocouple
0.1 Vol.%
0.001 Vol.%
0.01 Vol.%
0.1 %
1 ppm
1 ppm
1 ppm
1 ppm
1K
± 0.2 Vol. %
Z
± 0.2 Vol. %
Z
Z
Z
Z
Z
±2%
TA
Semiconductor
1K
± 0.2 K
Solid state
Calculation
Electro-chemical
NDIR
Electro-chemical
Electro-chemical
Electro-chemical
Calculation
Calculation
Filter paper method
Solid state
Solid state
0.01 hPa
1 ppm
1 ppm
0.001 Vol. %
1 ppm
1 ppm
1 ppm
0.1 %
0.1 %
±2%
Z
Z
Z
Z
Z
Z
± 0.1 %
± 0.1 %
0.01 m/s
100 RPM
±2%
±2%
0-20.9 Vol. %
0-10/20 Vol.%
0-20 Vol. %
0-100% LEL
0-2000 ppm
0- 100 ppm
0-4000 ppm
0- 200 ppm
-4°F - 2192°F
0°C - 1200°C
-4°F / 248°F
0°C - 120°C
±40 hPa
0-NOx max
0-1000/5000 ppm
0-1 Vol. %
0-200 ppm
0-5000 ppm
0-10000 ppm
0-99.9 %
1.0-9.99
0-9
0-80 m/s
180-10000 RPM
Air temperature
P
Draft
NOx Nitrogen oxides
NH3 Ammonia
N2O Nitrous Oxide
HCl Hydrogen Chloride
Cl2 Chlorine
H2 Hydrogen
Losses / Efficiency
Excess Air / Lambda
Soot
Velocity with Pitot tube
RPM Meter
** Different/customized ranges available.
STANDARD
Equipped with a maximum of 8 gas sensors
Z = 0 - 20 % of whole measurement range ± 5 %
21 - 100 % of whole measurement range ± 1 % of displayed measurement
MODEL
IMR 2800-IR
Dimensions (inch): 15 x 6.5 x 12.4
(375mm x 165mm x 300mm)
Weight: 17 lbs. (8 kg)
PART-NO.
IMR 28100
Represented by:
OPTIONAL ITEM
Soot Meter
RPM Meter
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice
THE PRIDE OF THE COMPAY - MADE I USA -
PART-NO.
Soot Meter
RPM Meter
Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727/328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
COMBUSTION GAS ANALYZER
IMR 1400 PS
IMR 1400 PS
„
„
„
„
„
measures flue gases of
‰ Boilers
‰ Burners
‰ Engines
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and will measure
all important parameters to adjust
and optimize the combustion process
has all features for a complete analysis
STANDARD FEATURES
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Oxygen
CO
Carbon Monoxide
Simultaneous measurement of
O2
NO
Nitric oxide
SO2
Sulfur dioxide
TG
Flue-gas temperature
AG
Ambient air temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Carbon Dioxide
Excess Air
CO2
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Thermal printer
Electronic controlled soot measurement
Draft measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
Rechargeable battery with charger
12V DC power jack
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe S with heated handle – length 0.9 ft , hose 11.5 ft
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
Gas sampling probes with different lengths
NO2-measurement
HC-measurement
THE PRIDE OF THE COMPANY - MADE IN USA -
Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727/328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
PARAMETER
O2
Oxygen
CO Carbon monoxide
COp CO pure
NO Nitric oxide
NO2 Nitric dioxide
SO2 Sulfur dioxide
HC Hydrocarbons
TG Flue gas temperature
TA Air temperature
P
Draft
CO2 Carbon dioxide
Efficiency
Losses
Excess Air
Soot
PRINCIPLE
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
RESOLUTION
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
5%
5%
5%
5%
5%
5%
±2%
RANGE
0-20.9Vol. %
0-2000/4000ppm
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-99.9 %
0-99.9 %
0-999 %
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
STANDARD
9
9
9
9
9
9
9
9
9
9
9
9
9
Other measurement ranges are available upon request
Equipped with max 4 sensors, HC or SO2 in exchange with NO2
MODEL
PART-NO.
IMR 1400 PS
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
IMR 14295
Useable for all fuels
Solid, liquid and gaseous fuels have varying calorific values according to
quality. To calculate fuel efficiency the IMR analyzers store the most
common fuel factors. Among other things the fact whether improvement is
made through a blower or atmospherically is taken into account. If desired
any other fuel factor can be entered by IMR. Apart from his IMR
combustion gas analyzer have programmable storage locations so that
the operator himself can enter unusual fuel factors on the job. The fuel
factor program is modified according to countries so that for each country
the appropriate fuel factors are available.
Represented by:
IMR Environmental Equipment International, Inc. reserves the right to adopt technical modifications without prior notice
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400
IMR 1400
Portable, continuous measuring flue gas
analysis instrument housed in an aluminum
case for measuring air temperature, flue gas
temperature, Oxygen O2, Carbon monoxide
CO (H2 comp.), Nitric oxide NO, Nitric dioxide
NO2, Sulfur dioxide SO2, Hydrocarbon HC,
losses, excess air, combustion efficiency,
Carbon dioxide CO2, draft and soot.
Simultaneous display of eight measured
variables on the illuminated LCD.
Integrated thermal printer and RS232
interface. Measurement printout or service
printout, both include date, time and fuel type.
ppm, mg, mg/kWh, mg (ref.O2) units are
selectable.
Automatic and manual CO-bypass.
Memory for 220 measurements.
Case has additional space for spare parts.
STANDARD INSTRUMENT
Gas analyzer in an aluminum case
Memory
Thermal printer
Gas sampling probe S, length 10.5" (270mm), flexible hose 11.5 ft. (3.5m)
Condensation trap with integrated filter
Soot filter paper, soot comparison table
Power cord
User manual
Model
Default
Sensors
Number of Optional
Sensors
Optional Sensors
1400 P
O2, CO
0
None
14280
1400 PL
O2, CO
1
NO, NO2, SO2, HC, H2S
14290
1400 PS
O2, CO
2
NO, NO2, SO2, HC, H2S
14295
Part-No.
THE PRIDE OF THE COMPAY - MADE I USA – Page 1

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
STANDARD EQUIPMENT
Illuminated display with
simultaneous display of 8
measured values
Languages: D, GB, F, USA, E,
TR, etc.
7 programmed and 5
programmable fuels
Measurement display is
switchable between ppm, mg,
mg(O2) and mg/kwh
Automatic zero calibration
within 3 minutes.
Re-calibration within 30 sec.
Interface RS 232
Printout of all measured and
calculated parameters
Electronic controlled soot
measurement
Automatic and manual CO
overflow shut-off
Battery status is shown on the
measurement display
After 1000 operating hours a
"Service needed" note appears
on the display.
Integrated self-check program
for all functions and parameters
Gas sampling probe, length
10.5" (270mm),NiCr-Ni,
flexible hose 11.5 ft. (3.5m)
Air probe, length 5"
(130mm), line 11.5 ft. (3.5m)
Condensation trap with
Integrated filter
Operating temperature
50°F..104°F
(10°C..40°C)
Storing temperature
-4°F..122°F
(-2°C..50°C)
Power supply 230V/50Hz,
110V/60Hz, 6VDC
TECHNICAL DATA
PARAMETER
MEASUREMENT
PRINCIPLE
RESOLUTION
ACCURACY RANGE**
O2 Oxygen
Electrochem. sensor
0.1 Vol.%
± 0.2 Vol. %
0-20.9 Vol. %
CO Carbon monoxide
Electrochem. sensor
1 ppm
Z
0-2000 ppm
1 ppm
Z
COp Carbon monoxide Calculation
STANDARD 1400 P
O2 corrected
NO Nitric oxide
Electrochem. sensor
1 ppm
Z
0-2000 ppm
1400PL 1400PS
NO2 Nitric dioxide
Electrochem. sensor
1 ppm
Z
0- 100 ppm
1400PL 1400PS
SO2 Sulfur dioxide
Electrochem. sensor
1 ppm
Z
0-4000 ppm
1400PL 1400PS
HC Hydrocarbons
Pellistor
0.1%
Z
0-100% LEL
1400PL 1400PS
H2S Hydrogen Sulfide
Electrochem. sensor
1 ppm
Z
0-200 PPM
1400PL 1400PS
TG Gas temperature
NiCr-Ni thermocouple
1K
±2%
-4°F..2192°F
-20°C..1200°C
TA Air temperature.
Semiconductor
1K
± 0.2 K
-4°F..248°F
-20°C..120°C
P Draft
Solid state
0.01 hPa
±2%
±40hPa
CO2 Carbon dioxide
Calculation
0.1 Vol. %
± 0.2 Vol. %
0- CO2 max
Combustion Efficiency Calculation
0.1 %
± 0.1 %
0-99.9 %
Losses
Calculation
0.1 %
± 0.1 %
0-99.9 %
Excess air
Calculation
0.1 %
± 0.1 %
1.0-9.99
Soot
Filter paper
0-9
Dimensions w x d x h
16.7 x 7.3 x 11.4 in. (425 x 185 x 290 mm)
Weight
13 lb. (5.8 kg)
** Different/customized ranges available.
Maximum of 3 sensors for IMR 1400 PL (3rd sensor is customer specified)
Maximum of 4 sensors for IMR 1400 PS (3rd sensor and 4th sensor are customer specified)
Z = 0 - 20 % of whole measurement range ± 5 % of maximum measurement
21 - 100 % of whole measurement range ± 1 % of displayed measurement
THE PRIDE OF THE COMPAY - MADE I USA – Page 2

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 – compact (SO2) Series
NEW
IMR 1400 – compact (SO2)
IMR 1400-c - compact (SO2)
Standard SO2-sensor
has been designed to measure
flue gases on
Boilers
Turbines
Cars
Burners
Engines
Trucks
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and will measure
all the important parameters to adjust
or optimize the combustion process
STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
CO
Carbon Monoxide
Sulfur Dioxide
SO2
TG
Flue-gas temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Excess Air
CO2
Carbon Dioxide
2
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft , hose 8 ft
Rechargeable battery with charger
Power supply 110V or 230V
NOW
SO -sensor
STANDARD
OPTIONAL FEATURES
♦
♦
♦
♦
♦
♦
Ambient air temperature probe
Gas sampling probe with heated handle
Gas sampling probes with different lengths
Electronic controlled soot measurement
Draft measurement
NOx-measurement
♦
♦
♦
♦
♦
♦
NO2-measurement
HC-measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
12V DC power jack
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IMR 1400-c - compact (SO2)
NEW
AND
IMPROVED
PARAMETER
O2
Oxygen
CO Carbon monoxide
COp CO pure
NO Nitric oxide
NO2 Nitric dioxide
SO2 Sulfur dioxide
HC Hydrocarbons
TG Flue gas temperature
PRINCIPLE
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
TA Air temperature
P
Draft
CO2 Carbon dioxide
Efficiency
Losses
Excess Air
Soot
RESOLUTION
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
5%
5%
5%
5%
5%
5%
±2%
RANGE
0-20.9Vol. %
0-2000/4000ppm
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-999 %
0-999 %
0-999 %
Other measurement ranges are available upon request
MODEL
IMR 1400-c – compact (SO2)
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
PART-NO.
IMR 14091
STANDARD
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
Equipped with max 4 sensors
IMR 1400-c/p -compact-printer (SO2)
IMR 1400-c/p – compact – printer (SO2) IMR 14191
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 – compact (NO) Series
NEW
IMR 1400 – compact (NO)
IMR 1400-c - compact (NO)
Standard NO-sensor
has been designed to measure
flue gases on
Boilers
Turbines
Cars
Burners
Engines
Trucks
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and will measure
all the important parameters to adjust
or optimize the combustion process
STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
CO
Carbon Monoxide
NO
Nitric oxide
TG
Flue-gas temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Excess Air
CO2
Carbon Dioxide
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft , hose 8 ft
Rechargeable battery with charger
Power supply 110V or 230V
NOW
NO-sensor
STANDARD
OPTIONAL FEATURES
♦
♦
♦
♦
♦
♦
Ambient air temperature probe
Gas sampling probe with heated handle
Gas sampling probes with different lengths
Electronic controlled soot measurement
Draft measurement
SO2-measurement
♦
♦
♦
♦
♦
♦
NO2-measurement
HC-measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
12V DC power jack
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IMR 1400-c - compact (NO)
NEW
AND
IMPROVED
PARAMETER
O2
Oxygen
CO Carbon monoxide
COp CO pure
NO Nitric oxide
NO2 Nitric dioxide
SO2 Sulfur dioxide
HC Hydrocarbons
TG Flue gas temperature
PRINCIPLE
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
TA Air temperature
P
Draft
CO2 Carbon dioxide
Efficiency
Losses
Excess Air
Soot
RESOLUTION
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
5%
5%
5%
5%
5%
5%
±2%
RANGE
0-20.9Vol. %
0-2000/4000ppm
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-999 %
0-999 %
0-999 %
Other measurement ranges are available upon request
MODEL
IMR 1400-c – compact (NO)
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
PART-NO.
IMR 14090
STANDARD
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
Equipped with max 4 sensors
IMR 1400-c/p -compact-printer (NO)
IMR 1400-c/p – compact – printer (NO) IMR 14190
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 – compact (HC) Series
NEW
IMR 1400 – compact (HC)
IMR 1400-c - compact (HC)
Standard HC-sensor
has been designed to measure
flue gases on
Boilers
Turbines
Cars
Burners
Engines
Trucks
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and will measure
all the important parameters to adjust
or optimize the combustion process
STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
CO
Carbon Monoxide
HC
Hydrocarbons
TG
Flue-gas temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Excess Air
CO2
Carbon Dioxide
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft , hose 8 ft
Rechargeable battery with charger
Power supply 110V or 230V
NOW
HC-sensor
STANDARD
OPTIONAL FEATURES
♦
♦
♦
♦
♦
♦
♦
Ambient air temperature probe
Gas sampling probe with heated handle
Gas sampling probes with different lengths
Electronic controlled soot measurement
Draft measurement
NOx-measurement
NO2-measurement
♦
♦
♦
♦
♦
♦
SO2-measurement
H2S-measurement
RS 232 interface
Memory for 200 measurements
12V DC power jack
CO-bypass valve with purging pump
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IMR 1400-c - compact (HC)
NEW
AND
IMPROVED
PARAMETER
O2
Oxygen
CO Carbon monoxide
COp CO pure
NO Nitric oxide
NO2 Nitric dioxide
H2S Hydrogen Sulfide
SO2 Sulfur dioxide
HC Hydrocarbons
TG Flue gas temperature
PRINCIPLE
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
TA Air temperature
P
Draft
CO2 Carbon dioxide
Efficiency
Losses
Excess Air
Soot
RESOLUTION
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
5%
5%
5%
5%
5%
5%
5%
±2%
RANGE
0-20.9Vol. %
0-2000/4000ppm
0-2000 ppm
0- 100 ppm
0- 500 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-999 %
0-999 %
0-999 %
Other measurement ranges are available upon request
MODEL
IMR 1400-c – compact (HC)
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
PART-NO.
IMR 14094
STANDARD
Equipped with max 4 sensors
IMR 1400-c/p -compact-printer (HC)
IMR 1400-c/p – compact – printer (HC) IMR 14194
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 series – compact
IMR 1400 - c
IMR 1400 – compact
has been designed to measure
flue gases on
Boilers
Burners
Engines
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and measures
all the important parameters to adjust
and optimize the combustion process
STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
CO
Carbon Monoxide
TG
Flue-gas temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Excess Air
CO2
Carbon Dioxide
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft , hose 8 ft
Rechargeable battery with charger
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
Ambient air temperature probe
Gas sampling probe with heated handle
Gas sampling probes with different lengths
Electronic controlled soot measurement
Draft measurement
NO-measurement
SO2-measurement
NO2-measurement
♦
♦
♦
♦
♦
♦
♦
CO2-measured (NDIR sensor)
HC-measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
12V DC power jack
Printer (1400 C/P)
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IMR 1400 - c
PARAMETER
O2
Oxygen
CO Carbon monoxide
COp CO pure
NO Nitric oxide
NO2 Nitric dioxide
SO2 Sulfur dioxide
HC Hydrocarbons
TG Flue gas temperature
PRINCIPLE
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
TA Air temperature
P
Draft
CO2 Carbon dioxide**
Efficiency
Losses
Excess Air
Soot
RESOLUTION
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
5%
5%
5%
5%
5%
5%
±2%
RANGE
0-20.9Vol. %
0-2000/4000ppm
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-999 %
0-999 %
0-999 %
Other measurement ranges are available upon request
**Optional: measured by CO2 NDIR sensor
MODEL
IMR 1400 – c
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
PART-NO.
IMR 14000
IMR 1400 – c/p (printer)
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
IMR 14100
STANDARD
Equipped with max 4 sensors
IMR 1400 –c/p (printer)
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA -
Environmental Equipment, Inc.
www.imrusa.com
IMR 1440FL / COFL
Exhaust Gas Analysis for Forklift Trucks
The exhaust gas analyzer, IMR 1440FL/COFL, is designed to measure exhaust gases of Forklift Trucks that are powered
by a variety of fuels. According to US regulations, the IMR 1440FL/COFL can measure soot and CO for Forklift Trucks. If
state regulations require NOx, the IMR 1440FL/COFL can be equipped with a NOx sensor. The IMR 1440COFL is equipped
with two CO sensors. One CO sensor operates in the low range and another CO sensor operates in the high range.
This new model can also measure the exhaust gas pressure before the soot filter. The measurement of the flue gas
temperature, oxygen, carbon dioxide and excess air are helpful for diagnostic reasons and the adjustment of the engine
to minimize CO emissions.
A flexible probe, which fits in most exhaust pipes, is inserted into the exhaust pipe and a clamp holds it in place.
Measuring exhaust gases is not only important to help control pollutants like CO, but it also helps optimizing fuel
efficiency and saving operating costs.
MEASURED PARAMETERS
• Oxygen
• Carbon Monoxide
• Nitric Oxides (Optional)
• Flue Gas Temperature
• Exhaust Gas Temperature
• Soot
CALCULATED PARAMETERS
• Carbon Dioxide
• Excess Air
O2 in Vol. %
CO in Vol. %
NOx in ppm
TG in °F
P in hPa
Filter Paper 0.0 – 9.9
CO2 in Vol. %
FEATURES
• Rugged case with additional compartments
• Menu navigation (soot, CO measurement or pressure measurement)
• Condensation trap with integrated filter
• 4-line, backlit LCD Display for simultaneous display of 8 values
• Rechargeable battery with status indicator; up to 6 hours
• Volume controlled soot measurement with soot paper and soot scale
• Exhaust gas pressure
• High speed thermal printer with an easy paper loading system
• Low CO switch valve with purge pump to protect the low CO-Sensor (IMR1440COFL)
• Diagnostic program
• Gas sampling probe with a flexible sheath
• Manual
• Power cord
Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711
Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
Environmental Equipment, Inc.
www.imrusa.com
OPTIONAL
• RS232
• Memory for 200 measurements
• NOx Sensor
TECHNICAL DATA
Parameter
O2
Oxygen
CO
Carbon Monoxide
CO
Carbon Monoxide
NOx
Nitric Oxides
TG
Flue Temperature
Principle
Electrochemical
Electrochemical
Electrochemical
Electrochemical
Thermocouple K
Resolution
0.1Vol. %
0.001 Vol. %
0.001 Vol. %
1 ppm
1K
Accuracy
±0.2%
Z
Z
Z
±2%
P
CO2
SZ
Solid State
Calculation
Filter Paper
0.1hPa
0.1 Vol. %
0.1
±2%
±0.2%
Exhaust Pressure
Carbon Dioxide
Soot
Fuels:
Gas sampling probe:
Power Supply:
Dimensions:
Weight:
Operating Temperature:
Range
0 - 20.9 Vol. %
0-10.000 Vol. %
0-0.200 Vol. %
0-5,000 ppm
-20 – 1200 °C
-4 °F - 2192°F
0 - 350 hPa
0 – CO2 max
0 - 9.9
Diesel, Natural Gas, Propane, Biogas
Biogas, Gasoline
Flexible
le sheath, length 250mm, hose 3.
3.5m (11.5 ft)
120VAC/60Hz 230VAC/
230VAC/50Hz, Rechargeable Battery
IMR1440FL/COFL: 245 x 185 x 290mm
IMR1440FL/COFL: 5.8Kg
0-40oC; 10
10-90% RH non condensing
IMR1440FL Part #:: 1440
14401
IMR1440COFL Part #:: 144
14406
IMR1440FL-KIT*
IMR1440COFL-KIT*
Part #: 14401-K
Part #: 14406-K
Other measuring ranges / sensors / fuels upon request (max. 4 sensors)
*Includes RPM Meter, CD100A and Soot Meter
Z = 0 - 20% of the measuring range 5%
% of the maximum value
= 21 – 100% of the measuring range 1%
% of the displayed value
ACCESORIES
RPM METER
Part #: RPM Meter
•
•
•
CD100A
Part #: CD100A
Tachometer: 180-10,000 RPM
DC: 200mV to 1000V
AC: 200V to 750V
SOOT METER
Part #: Soot Meter
•
•
•
•
•
Adjustable tick rate
Long 18" (45cm) flexible gooseneck
Detects gas leaks on gas fire forklift
trucks
IMR DATA – DATA Transfer Software
Part #: 90670
Measures the soot number from
0.0 to 9.9
More reliable than a paper scale
Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711
Phone 727-328-2818
2818 — 800
800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
1440FL
Optional
1440FLCO
Optional

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727/328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
COMBUSTION GAS ANALYZER
IMR 1400 – IR
IMR 1400 – IR
Measures CO2 with NDIR Technology
This latest model does not only measure the most common
parameters but also CO2 !!
Measures flue gases of
Boilers
Burners
Engines
Developed to meet the customers need
High quality combustion gas analyzer using the
latest sensor technology
Easy to use and will measure
all important parameters to adjust
and optimize the combustion process
Includes all needed features for a complete analysis
STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Simultaneous measurement of
O2
Oxygen
CO2
Carbon Dioxide
NO
Nitric oxide
CO
Carbon monoxide
TG
Flue-gas temperature
AG
Ambient air temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
Excess Air
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
Thermal printer
Electronic controlled soot measurement
Draft measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
Rechargeable battery with charger
12V DC power jack
Integrated self-check program
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe S with heated handle – length 0.9 ft , hose 11.5 ft
Power supply 110V or 230V
N
NE
EW
W
C
CO
O22 N
ND
DIIR
RS
SE
EN
NS
SO
OR
R
OPTIONAL FEATURES
♦
♦
♦
♦
Gas sampling probes with different lengths
NO2-measurement
SO2-measurement
HC/CH4-measurement NDIR
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727/328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
PARAMETER
O2
Oxygen
CO2
Carbon dioxide
CO
Carbon monoxide
COp
CO pure
NO
Nitric oxide
NO2
Nitric dioxide
SO2
Sulfur dioxide
HC/CH4 Hydrocarbons
TG Flue gas temperature
TA
Air temperature
PRINCIPLE
Electro-chemical cell
NDIR
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
NDIR
NiCr-Ni
thermocouple
Semiconductor
P
Draft
Solid state
0.01 hPa
±2%
Calculation
Calculation
Calculation
Filter paper method
1%
1%
1%
± 0.5 %
± 0.5 %
±2%
Efficiency
Losses
Excess Air
Soot
RESOLUTION
0.1 Vol.%
0.01 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
ACCURACY
± 0.2 %
±5%
5%
5%
5%
5%
5%
5%
±2%
1K
± 0.5 K
RANGE
0-20.9 Vol. %
0- 30 Vol.%
0-2000/4000ppm
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
-20°C / 1200°C
-4°F / 248°F
-20°C / 120°C
±40 hPa
0-100 %
0-100 %
0-999 %
STANDARD
Other measurement ranges are available upon request
Max 4 sensors are possible Standard: O2, CO, CO2 – 1 more sensor is possible(NO or NO2 or SO2 or HC)
MODEL
PART-NO.
IMR 1400 - IR
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
IMR 14296
Useable for all fuels
Solid, liquid and gaseous fuels have varying calorific values according to
quality. To calculate fuel efficiency IMR analyzers store the most common
fuel factors. The fact whether improvement is made through a blower or
atmospherically is taken into account. If desired any other fuel factor can
be entered by IMR. Apart from this IMR combustion gas analyzers have
programmable storage locations so that the operator himself can enter
unusual fuel factors on the job. The fuel factor program is modified
according to countries so that for each country the appropriate fuel factors
are available.
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 FO
IMR 1400 FO
IMR 1400 FO
The combustion gas analyzer IMR 1400 FO is easy to
use, compact and rugged.
One CO-sensor is installed for high CO-measurements.
This helps to get the best possible accuracy for different
applications (e.g. wood fired applications or forklifts).
Measured parameters:
- Oxygen O2
- Carbon monoxide CO in Vol. %
Calculated parameters:
- Losses qA
- Combustion Efficiency ETA
- Excess Air LAMBDA
- Carbon dioxide CO2
The series IMR 1400 FO can also measure draft, soot
and stack gas temperature and ambient temperature.
IMR 1400FO – Overview
„
„
„
„
„
„
„
„
Case:
Rugged aluminum with an
additional compartment
Sensors:
O2-CO
Display:
Illuminated and simultaneous
display of 8 values
Fuels:
7 programmed; 5 programmable
Units:
ppm, mg, mg(O2), mg/kWh
Interface:
RS232
Memory:
200 measurements
Battery:
Status is shown on the LCD;
8 hrs
„
„
„
„
Printer:
Highspeed thermal-printer;
Width 58mm;
Capable of printing 1, 2 or 3
printouts at once with all values
including date, time and fuel type
Soot measurement:
Electronic controlled pump
Zero-point adjustment:
3 min
Serviceprogram:
Component check and printout
capability of all parameters;
„
„
„
„
„
„
Monitoring working hours
Gas sampling probe:
Heated handle (soot);
l=270mm; ∅ 10mm;
Thermocouple Type K;
Hose length 3.5m
Ambient temperature probe:
l=150mm;
Line 3.5m
Condensation trap:
Integrated Filter
Power:
12VDC;
240VAC/50Hz;
120VAC/60Hz
Operating temperature:
10°C..40°C
Storage temperature:
-20°C..50°C
THE PRIDE OF THE COMPANY - MADE IN USA © Copyright 2012 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
TECHNICAL DATA
PARAMETER
PRINCIPLE
RES.
ACC.
RANGE
IMR 1400CO
O2
Electro-chemical
0.1 Vol.%
± 0.2 %
0-20.9Vol. %
9
0.001 Vol.%
Z
0-4 Vol.%
Oxygen
COCarbon monoxideElectro-chemical
NO
Nitric oxide
Electro-chemical
1 ppm
Z
0- 2000 ppm
optional
SO2
Sulfur dioxide
Electro-chemical
1 ppm
Z
0- 4000 ppm
optional
TG
Stack gas temperature
Thermocouple K
1K
±2%
-20°C / 1200°C
9
VL
Ambient temperature
Semiconductor
1K
± 0.5 K
-20°C / 120°C
9
P
Draft
Solid state
0.01 hPa
±2%
-30hPa / +50hPa
9
CO2
Carbon dioxide
Calculation
0.1 Vol.%
± 0.2 %
0- CO2 max
9
ETA
Efficiency
Calculation
0.1 %
± 0.5 %
0-99.9 %
9
qA
Losses
Calculation
0.1 %
± 0.5 %
0-99.9 %
9
λ
Excess Air
Calculation
0.01
±2%
1-9.99
9
Soot
Filter paper
9
Max. 4 sensors
Other measuring ranges upon request
Z = 0-20% of the measuring range ± 1% of the maximum value
= 21-100% of the measuring range ± 5% of the displayed value
STANDARD
Combustion gas analyzer
Dimensions in mm: 425 x 185 x 290
Weight in kg: 5.8
High speed thermal printer
Gas sampling probe S with heated handle
Ambient temperature probe
Condensation trap with integrated filter
Soot paper, soot scale
Power cord
Manual
Calibration certificate
Distributor:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA © Copyright 2012 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 CO
IMR 1400 CO
IMR 1400 CO
The combustion gas analyzer IMR 1400 CO is easy to
use, compact and rugged.
Two CO-sensors are installed, one for low COmeasurements and one for high CO-measurements.
This helps to get the best possible accuracy for different
applications (e.g. wood fired applications).
Measured parameters:
- Oxygen O2
- Carbon monoxide CO in ppm
- Carbon monoxide CO in Vol. %
Calculated parameters:
- Losses qA
- Combustion Efficiency ETA
- Excess Air LAMBDA
- Carbon dioxide CO2
The series IMR 1400 CO can also measure draft, soot
and stack gas temperature and ambient temperature.
IMR 1400CO – Overview
„
„
„
„
„
„
„
„
Case:
Rugged aluminum with an
additional compartment
Sensors:
O2-CO-CO
Display:
Illuminated and simultaneous
display of 8 values
Fuels:
7 programmed; 5 programmable
Units:
ppm, mg, mg(O2), mg/kWh
Interface:
RS232
Memory:
200 measurements
Battery:
Status is shown on the LCD;
6 hrs
„
„
„
„
„
Printer:
Highspeed thermal-printer;
Width 58mm;
Capable of printing 1, 2 or 3
printouts at once with all values
including date, time and fuel type
CO-Switch:
Solenoid valve to automatically
switch between the low and high
CO-sensor.
2nd pump to purge the low COsensor (faster regeneration);
Soot measurement:
Electronic controlled pump
Zero-point adjustment:
3 min
Serviceprogram:
Component check and printout
capability of all parameters;
„
„
„
„
„
„
Monitoring working hours
Gas sampling probe:
Heated handle (soot);
l=270mm; ∅ 10mm;
Thermocouple Type K;
Hose length 3.5m
Ambient temperature probe:
l=150mm;
Line 3.5m
Condensation trap:
Integrated Filter
Power:
12VDC;
240VAC/50Hz;
120VAC/60Hz
Operating temperature:
10°C..40°C
Storage temperature:
-20°C..50°C
THE PRIDE OF THE COMPANY - MADE IN USA © Copyright 2006 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
TECHNICAL DATA
PARAMETER
PRINCIPLE
RES.
ACC.
RANGE
IMR 1400CO
O2
Oxygen
Electro-chemical
0.1 Vol.%
± 0.2 %
0-20.9Vol. %
9
CO
Carbon monoxide
Electro-chemical
1 ppm
Z
0-2000 ppm
9
CO
Carbon monoxide
Electro-chemical
0.001 Vol.%
Z
0-4.000 Vol.%
9
NO
Nitric oxide
Electro-chemical
1 ppm
Z
0- 2000 ppm
optional
SO2
Sulfur dioxide
Electro-chemical
1 ppm
Z
0- 4000 ppm
optional
TG
Stack gas temperature
Thermocouple K
1K
±2%
-20°C / 1200°C
9
VL
Ambient temperature
Semiconductor
1K
± 0.5 K
-20°C / 120°C
9
P
Draft
Solid state
0.01 hPa
±2%
-30hPa / +50hPa
9
CO2
Carbon dioxide
Calculation
0.1 Vol.%
± 0.2 %
0- CO2 max
9
ETA
Efficiency
Calculation
0.1 %
± 0.5 %
0-99.9 %
9
qA
Losses
Calculation
0.1 %
± 0.5 %
0-99.9 %
9
λ
Excess Air
Calculation
0.01
±2%
1-9.99
9
Soot
Filter paper
9
Other measuring ranges upon request
Z = 0-20% of the measuring range ± 1% of the maximum value
= 21-100% of the measuring range ± 5% of the displayed value
Max. 4 sensors
STANDARD
Combustion gas analyzer
Dimensions in mm: 425 x 185 x 290
Weight in kg: 5.8
High speed thermal printer
Gas sampling probe S with heated handle
Ambient temperature probe
Condensation trap with integrated filter
Soot paper, soot scale
Power cord
Manual
Calibration certificate
Model
Sensors
Part-No.
IMR 1400CO
O2, CO, CO
14291
Distributor:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA © Copyright 2006 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1400 – compact (NO/SO2) Series
NEW
IMR 1400 – compact (NO/SO2)
IMR 1400-c - compact (NO/SO2)
Standard NO-sensor and SO2-sensor
„
„
„
„
has been designed to measure
flue gases on
† Boilers
† Turbines
† Cars
† Burners
† Engines
† Trucks
has been developed to meet
the customers need
is a high quality combustion
gas analyzer using the
latest sensor technology
is easy to use and will measure
all the important parameters to adjust
or optimize the combustion process
STANDARD FEATURES
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Oxygen
Simultaneous measurement of
O2
CO
Carbon Monoxide
NO
Nitric oxide
SO2
Sulfur dioxide
TG
Flue-gas temperature
Calculation of following parameters according ASME-equations
Combustion efficiency
Losses
NO-sensor
Excess Air
Carbon Dioxide
CO2
and
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
SO2-sensor
Integrated self-check program
STANDARD
Simultaneous display of eight parameters on the illuminated display
Unit selection :
ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft , hose 8 ft
Rechargeable battery with charger
Power supply 110V or 230V
OPTIONAL FEATURES
♦
♦
♦
♦
♦
♦
Ambient air temperature probe
Gas sampling probe with heated handle
Gas sampling probes with different lengths
Electronic controlled soot measurement
Draft measurement
NO2-measurement
♦
♦
♦
♦
♦
♦
HC-measurement
CO-bypass valve with purging pump
RS 232 interface
Memory for 200 measurements
12V DC power jack
Pitot Tube (Flow Measurement)
THE PRIDE OF THE COMPANY - MADE IN USA -

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IMR 1400-c - compact (NO/SO2)
NEW
AND
IMPROVED
PARAMETER
PRINCIPLE
RESOLUTION
ACCURACY
RANGE
O2
CO
COp
NO
NO2
SO2
HC
TG
Electro-chemical cell
Electro-chemical cell
Calculation
Electro-chemical cell
Electro-chemical cell
Electro-chemical cell
Sensor
NiCr-Ni
thermocouple
Semiconductor
Solid state
Calculation
Calculation
Calculation
Calculation
Filter paper method
0.1 Vol.%
1 ppm
1 ppm
1 ppm
1 ppm
1 ppm
0.1%
1K
± 0.2 %
5%
5%
5%
5%
5%
5%
±2%
0-20.9Vol. %
0-2000/4000ppm
1K
0.004” H2O
0.1 Vol.%
1%
1%
1%
± 0.5 K
±2%
± 0.2 %
± 0.5 %
± 0.5 %
±2%
-4°F / 248°F
- 12” / 20” H2O
0- CO2 max
0-99.9 %
0-99.9 %
0-999 %
Oxygen
Carbon monoxide
CO pure
Nitric oxide
Nitric dioxide
Sulfur dioxide
Hydrocarbons
Flue gas temperature
TA Air temperature
P
Draft
CO2 Carbon dioxide
Efficiency
Losses
Excess Air
Soot
Other measurement ranges are available upon request
0-2000 ppm
0- 100 ppm
0-4000 ppm
0-100% LEL
-4°F / 2192°F
STANDARD
14090/14190
9
9
9
9
14095/14195
Equipped with max 4 sensors
MODEL
IMR 1400-c – compact (NO)
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
PART-NO.
IMR 14090
IMR 1400-c – compact (NO&SO2)
Dimensions (inch): 12 x 9 x 4.6
Weight: 6.7 lb. (2.9kg)
IMR 14095
IMR 1400-c/p – compact – printer (NO)
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
IMR 14190
IMR 1400-c/p – compact – printer (NO&SO2)
Dimensions (inch): 16.7 x 7.3 x 11.4
Weight: 13 lb. (5.8kg)
IMR 14195
IMR1400-C/P (NO/SO2)
Represented by:
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA -
9
9
9
9
9
Environmental Equipment, Inc.
TX450
THERMO LOGGER
Support Thermocouple Type: K, J, E, T
250 VAC Isolated input Protection
FEATURES
•
•
•
•
•
•
•
•
•
•
Auto range
PC interface
LED back light
Four channel input
Four channel display
Resolution 0.1oC/0.1oF
With windows software
Auto shut off for battery saving
16, 000 records data logger each channel
Isolated input protection up to 250VAC
between any two inputs
Four Channel Display
T1-T2 Display
SPECIFICATIONS
Measurement Range: -200oC~1372oC(K type)
-328oF~2501oF(K type)
Accuracy: -200oC~1372oC…. +/-0.1rdg + 0.7oC
-328oF~…. +/-0.1rdg +0.7oF
Battery: 9V Battery
Operating Condition: -10oC to 50oC (<90%RH)
Storage Condition: -40oC to 60oC(<75%RH)
Dimensions: 197mm X 65mm X 36mm
Weight: Approx. 310g
IMR® Environmental Equipment, Inc.
3634 Central Ave. St. Petersburg, FL 33711 USA – Phone: 727-328-2818 – E-mail: [email protected]
WWW.IMRUSA.COM
ENVIRONMENTAL EQUIPMENT, INC.
SOOT METER
Technical data:
Accurately measures the soot number from 0.0 to 9.9
More reliable than a paper soot scale
Approximately 100,000 measurements with 1 set of batteries (or accus)
Input voltage 2.8 - 5.0 volts
3 x 1.5 Volt AA batteries or 3 x 1.2 Volt Mignon accus
Measuring spot diameter 2.5 mm
The Soot Meter possesses the following important elements:
3 Pushbuttons M, C, P
16-digit LCD-display
Light sensor
Battery case for 3 1.5V AA batteries
IMR® Environmental Equipment, Inc.
3634 Central Ave. St. Petersburg, FL 33711 USA – Phone: 727-328-2818 – E-mail: [email protected]
WWW.IMRUSA.COM
Environmental Equipment, Inc.
IMR 5000
SDU5000
Aspects
• 6.4"Color TFT LCD with 640X480 pixels resolution
• The High Flexibility :
1. User configurable I / O
2. Expandable modular architecture
3. Flexible screen configuration
• User-Friendly:
1. Soft keys coupled with interactive dialog
2. Simplify setup & operation procedures
3. Easy - to - access function keys
• Various Display Formats:
1. Vertical trend , Horizontal trend Bar Graph, Numerical or
mixed
• Fast sampling rate (200msec for all channels)
• Programmable alarm and messages
• Infrared detector that allows LCD to shut off automatically to
prolong LCD life and power
Graph and Bar Display
Page 1 of 2
Main Screen Display
Environmental Equipment, Inc.
IMR 5000
TECHNICAL DATA
SDU5000
• Data Logger
• 4 – 20mA or 0 – 20mA output
• RS-232 Output (Optional)
• RS-485 Output (Optional)
• Communication through Ethernet
• Storage Media (SD card 1G)
• Capable of working between temperature of -10 and 50oC
• 6.4” TFT Color LCD with VGA Display in 640x480 pixels
• 6 or 18 isolated Analog Inputs maximum
• Plug & play I/O cards for easy expansion
• Infrared detector to prolong LCD lifetime
• High accuracy 18-bit A-D Analog Input
• 15-bit D-A Analog Output
• Bench top with convenient portable handle, easily converted into panel mount
• Dimensions: Panel Mount style: 166 (W) x 144 (H) x 174mm (D)
• Dimensions: Bench Top style: 166 (W) x 192 (H) x 194mm (D)
• 90-250VAC, 47-63Hz, 60VA, 30W maximum
• 11-18VDC or 18-36 VDC, 60VA, 30W maximum
• For more detailed specifications, please see page 8 of the manual:
http://www.imrusa.com/PDF/SDU5000_manual.pdf
Page 2 of 2
ENVIRONMENTAL EQUIPMENT, INC.
RPM METER
DESCRIPTION
This automotive multimeter allows you to measure
AC/DC voltage, dwell angle and ENGINE RPM from the
comfort of your own garage. With the large easy-to-read
LCD display, readings are clearly visible even in low-light
settings. Functions on this automotive multimeter include
diode test, HFT auto range, resistance measurement,
capacitor test, Ohm, tach, low battery, auto zero,
continuity and temperature.
• Large easy-to-read LCD display
• Automatic polarity
• K-type temperature kit
• Accurately measure dwell angle and engine RPM
• Reads AC and DC voltage
Uses one 9V battery, included.
SPECIFICATIONS
Name
RPM-METER
Battery(s) Included (y/n)
Yes
Display type
LCD
Product Depth
7-7/8 in.
Product Height
1-1/2 in.
Product Width
3-4/5 in.
Accessories Included
Black and red test leads, bead probe,
spark plug signal pickup clamp, 9 V
battery, and hard shell carry case,
automatic shutoff
Tachometer
180 – 10,000 RPM
DC Voltage
200mV to 1000V
AC Voltage
200V to 750V
DC Current
20 mA t0 10A
Ohms
200 to 2M
Transistor
PNP and NPN
IMR® Environmental Equipment, Inc.
3634 Central Ave. St. Petersburg, FL 33711 USA – Phone: 727-328-2818 – E-mail: [email protected]
WWW.IMRUSA.COM

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
NEW
REFRIGERANT LEAK DETECTOR
RLD10
NEW
RLD10
Detect leaking refrigerant using the high sensitivity mode
then switch to the low sensitivity mode to pinpoint its
source. If background noise makes the audible tick hard to
hear, you can count on the color scaled LED indicators.
¾
Audible tick rate
¾
LED panel indicates refrigerant leak concentration
¾
Two position sensitivity selector
¾
Auto zeros when turned on
¾
Long gooseneck probe
¾
One-hand operation
¾
Automatically detects all existing halogen refrigerants
and blends
¾
Fast response time (< 1 second)
SPECIFICATIONS
Power Supply
9V Alkaline battery
Battery life
Approx. 8 hours
Sensor
Advanced ionization detection
Sensitivity
.5 oz. per year R134A
Warm-Up
< 10 seconds
Response time
< 1 second
Sensor
Gooseneck
18” (450mm)
Sensor Tip Guard
Ambient conditions
32 to 102°F (0 to 40°C)
0-80% RH (non condensing)
Level Indicators
Audible: tick rate
Visual: LEDs
REPLACEMENT PARTS
ACCESSORIES
Vinyl Carrying Case
Hard Carrying Case
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
© Copyright 2012 IMR Environmental Equipment, Inc.
Environmental Equipment, Inc.
IMR 5000
Observer II Software
Aspects
• All of the features of Observer I plus streaming real time data
• Data can be streamed over Ethernet, RS232 or RS485
• User customizable display options independent of recorder
• User-Friendly:
1. Remote programming and viewing
2. Simplify setup & operation procedures
3. Easy - to - access and edit all channels
• Various Display Formats:
1. Vertical trend , Horizontal trend Bar Graph, Numerical or
mixed
• Fast sampling rate (200 msec for all channels)
• Programmable alarm and messages
Digital Display
Page 1 of 1
Bar Graph Display

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
IR-THERMOMETER
INF155
o
o
o
o
o
MAX-Hold
Auto Shut off after 15 seconds
Holster
Backlit display
Over-molded handle with comfort grip
Temperature
INF185
0.1°F (0.1°C)
Accuracy
±2% of reading or 4°F (2°C) whichever is greater
Distance to spot
10:1
Operating range
32°F-122°F (0-50°C)
Emissivity
Battery
0.95
2x AAA-Batterien / typ. 18 hrs
Dimension
3.25“ x 7“ x 1,75“ (8.3 x 17.8 x 4.4 cm)
Weight
7 oz. (200g)
o
o
o
o
o
o
o
o
o
MIN/MAX/DIFF/AVG – Hold
Auto Shut off after 15 seconds
Worklight
Contact probe input – Thermocouple Type K
Adjustable emissivity
Holster
Hi/Lo - Alarm
Backlit display
Over-molded handle with comfort grip
Temperature
INF215
-58°F to 750°F (-50°C to 400°C)
Resolution
-76°F to 932°F (-60°C to 500°C)
Resolution
0.1°F (0.1°C)
Accuracy
Thermocouple Type K
± 1.8°F (1.0°C)
-83.2°F to 1999°F (-64°C to 1400°C)
Accuracy
±1% of reading or 1.8°F (1.0°C)
Distance to spot
12:1
Operating range
32°F-122°F (0-50°C)
Emissivity
Adjustable
Battery
Dimension
2x AAA-Batterien / typ. 18 hrs
3.25“ x 7“ x 1,75“ (8.3 x 17.8 x 4.4 cm)
Weight
7 oz. (200g)
o
o
o
o
o
o
o
o
o
MIN/MAX/DIFF/AVG - Hold
Auto Shut off after 15 seconds
UV - worklight
Contact probe input – Thermocouple Type K
Adjustable emissivity
Holster
Hi/Lo-Alarm
Backlit display
Over-molded handle with comfort grip
Temperature
-76°F to 1400°F (-60°C bis 760°C)
Resolution
0.1°F (0.1°C)
Accuracy
± 1.8°F (1.0°C)
Thermocouple Type K
-83.2°F to 1999°F (-64°C to 1400°C)
Accuracy
Distance to spot
±1% of reading or 1.8°F (1.0°C)
30:1
Operating range
32°F to 122°F (0-50°C)
Emissivity
Adjustable
Battery
2x AAA-Batterien / typ. 18 hrs
Dimension
3.25“ x 7“ x 1,75“ (8.3 x 17.8 x 4.4 cm)
Weight
7 oz. (200g)
IMR Enviromental Equipment, Inc. reserves the right to adopt technical modification without prior notice.
Environmental Equipment, Inc.
IMR IX616 Multi Gas Detector
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Gas sampling method: natural diffusion
Gas sensor type: catalytic (for combustible
gas) and electrochemical (for H2S, CO and
O2)
Detecting gas: combustible gas, H2S, CO, O2
Accuracy: ≤±5%FS
Response time: ≤30s
Indication: LCD displays real-time and
system status, LED, audio and vibration alert
for gas leakage, fault and low voltage
Working environment: -20 to 50°C, 95% RH
(no dew)
Power source: 3.6V DC Rechargeable Li-on
battery, 1,800Ah
Charging time: ≤6h
Working time: ≥8h continuously (without
alarming)
Gas sensor life: 2 years
Explosion-proof grade: ExiallCT4
Protection grade: IP65
Weight: 200g (with battery)
Dimensions: 116 x 66 x 30mm
Gas Ranges
IMR Environmental Equipment, Inc.
3634 Central Ave.
St. Petersburg, Fl 33711
Phone: 1-800-RING-IMR
E-mail: [email protected]
Website: www.imrusa.com
Page 1 of 1
Environmental Equipment, Inc.
IMR IX170 Single Gas Detector with ATEX
IX170 portable single gas detector
can make continuous detection to
combustible and toxic gases. It is
suitable for combustible and toxic
gas leakage detection in
underground pipe or mines, and
keeps the workers safe, prevents
the facilities from being destroyed.
The detector, adopting excellentquality sensor, makes detection in
the way of natural diffusion. It has
good sensitivity and reproducibility.
The detector adopts embedded MCU
controller, easy to operate.
The shell adopts special high
strength material and anti-smooth
rubber, with the characters of
water-proof, explosion-proof and
dust-proof. The alarms are visual
and audible with vibration.
Gas Ranges:
Model
IX170-CH4
IX170-C3H8
IX170-H2
IX170-H2
IX170-H2S
IX170-CO
IX170-CO
IX170-O2
IX170-C2H5OH
IX170-+H3
IX170-CL2
IX170-SO2
Range
0-100%LEL
0-100%LEL
0-100%LEL
0-1000ppm
0-100ppm
0-1000ppm
0-2000ppm
0-30%vol
0-100%LEL
0-100ppm
0-20ppm
0-100ppm
L-Alarm Range
10%LEL~5%LEL
10%LEL~25%LEL
10%LEL~25%LEL
20ppm~150ppm
5ppm~15ppm
25ppm~100ppm
25ppm~100ppm
16%vol~19.5%vol
10%LEL~25%LEL
20ppm~30ppm
3ppm~10ppm
1ppm~3ppm
IMR Environmental Equipment, Inc.
3634 Central Ave.
St. Petersburg, Fl 33711
Phone: 1-800-RING-IMR
E-mail: [email protected]
Website: www.imrusa.com
Page 1 of 1
H-Alarm Range
25%LEL~80%LEL
25%LEL~80%LEL
25%LEL~80%LEL
150ppm~500ppm
15ppm~30ppm
100ppm~500ppm
100ppm~500ppm
22.5%vol~24%vol
25%LEL~80%LEL
30ppm~70ppm
5ppm~15ppm
3ppm~10ppm
L-Alarm
20%LEL
20%LEL
20%LEL
35ppm
10ppm
35ppm
35ppm
19.5%vol
20%LEL
25ppm
5ppm
2ppm
H-Alarm
50%LEL
50%LEL
50%LEL
250 ppm
15ppm
200ppm
200ppm
23.5%vol
50%LEL
50ppm
10ppm
5ppm
Environmental Equipment, Inc. IMR 1050X
IMR 1050X
The newly redesigned IMR 1050X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro chemical O2 sensor with the EOS Technology™ CO2 sensor, the IMR 1050X now takes direct CO2 measurements and calculates the O2 level. This lowers the cost of ownership by doing away with the annual replacements of the O2 sensor and reducing calibration drifting typically found with standard electro‐chemical sensors. The EOS Technology sensor has an unmatched industry‐leading life expectancy of 10 years! Features
 Measures: Differential flue temperature, Carbon Dioxide (CO2), flue & ambient carbon monoxide (CO) & Differential Pressure
 Calculates: oxygen, gross/net efficiency, excess air, & CO air free
 Worklight
 4 line backlit LCD display
 179 memory positions
 User customizable parameters view
 Individual report printouts
 Unique DMM style rotary selector
 Protective boot w/integral magnet
 Real time clock
 CO readings to 1 ppm
 Infrared printer port
Measures, Calculates** or Displays:






Oxygen (O2)**
Carbon Monoxide (CO)
Carbon Dioxide (CO2)
Combustion efficiency**
Pressure (draft)
Date & time






Temperature (flue, inlet & net**)
Excess air**
CO Air Free**
Battery level
Fuel type
Nitric Oxide (IMR 1050X‐NO)
www.imrusa.com 3634 Central Ave. St. Petersburg, Fl 33711 * Phone: 727‐328‐2818 * 1‐800‐RING‐IMR * Fax: 727‐328‐2826 Email: [email protected] Page 1 of 3 Environmental Equipment, Inc. IMR 1050X Specifications
Temperature Measurement Flue Temp Range Inlet Temperature (probe ‐ T2) Inlet Temperature (ambient) Net Temperature (_T)** Resolution Flue (T1, Inlet T2 & _T) Accuracy Inlet Temperature Accuracy Gas Measurement Oxygen O2 resolution / accuracy Carbon Monoxide (CO) CO resolution / accuracy Carbon Dioxide (CO2) CO2 Resolution / accuracy Efficiency** Efficiency resolution / accuracy Excess Air** Excess Air resolution / accuracy CO / CO2 ratio** CO / CO2 resolution / accuracy Nitric Oxide (NO1) NO1 resolution / accuracy Pressure (Differential) Pressure Resolution 1050X 1050X‐NO 20~2400°F (‐29~1315°C) 20~2400°F (‐29~1315°C) 32~112°F (0~50°C) 20~2400°F (‐29~1315°C) 0.1°C/F ±(0.3% rdg +3.6°F(2°C)) ±(0.3% rdg +1.8°F(1°C)) 0~21%**
0~21%**
0.1% / ±0.3%
0.1% / ±0.3%
0~2000 ppm(4000 max 15 min)* 1ppm / ±10ppm < 100ppm ±5% rdg > 100ppm 0~20%
0~20% 0.1% / ±2%
0.1% / ±2%
0~99.9%**
0~99.9%**
0.1% / ±3%
0.1% / ±3%
0~250%
0~250% 0.1% / ±3%
0.1% / ±3%
0~0.999
0~0.999 0.001 / ±5% rdg
0.001 / ±5% rdg
‐
0~100 ppm
‐
±5 ppm < 100 ppm
Range
Accuracy ±0.08” wc (±0.2mBar)
±0.002” wc (±0.005mBar)
±0.4” wc (±1mBar) ±32” ±0.01” wc (±0.03mBar) wc (±80mBar) ±3% rdg 0.001” wc < 9.999” wg 0.01” wc < 10.0” wg 0.001 mBar < 24.999 mBar 0.01 mBar > 25 mBar * Measured at STP (standard temperature and pressure) ** Calculated value 1050X 1050X‐NO 1050X KIT 1050X‐NO KIT O2, CO2, CO, draft, Condensation Trap, Flue Probe Particle Filter, Hard Case, Batteries, Quick Start Guide Owner’s Manual O2, CO2, CO, NO, draft, Condensation Trap, Flue Probe, Particle Filter, Hard Case, Batteries, Quick Start Guide Owner’s Manual 1050X Analyzer, Flue Probe, IR Printer, (2) K‐Type Temp Probes, (2) Static Pressure Hoses (1) True Draft Probe, Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner’s Manual 1050X‐NO Analyzer Flue Probe, IR Printer, (2) K‐Type Temp Probes, (2) Static Pressure Hoses, (1) True Draft Probe, Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner’s Manual www.imrusa.com 3634 Central Ave. St. Petersburg, Fl 33711 * Phone: 727‐328‐2818 * 1‐800‐RING‐IMR * Fax: 727‐328‐2826 Email: [email protected] Page 2 of 3 Environmental Equipment, Inc. More Details About IMR 1050X
COMBUSTION • Verify Ambient CO
• Verity CO Air Free
• Verify Proper Combustion
• Verify Combustion Gas, Make Up 02, CO, CO2,
Excess Air
• Verify Stack Loss and Efficiency
Allows for live fire / real time analysis and trouble
shooting, while verifying and documenting needed
adjustments, repairs or replacements.
MODULATING & MULTI STAGE SYSTEM SET UP & TESTING: The IMR 1050X allows the technician to simultaneously set gas pressure while doing a combustion test. Which allows for live fire viewing of combustion gases (over / under fire) while viewing and setting gas pressure to manufacture suggested specifications. USER PROGRAMMABLE AUXILIARY SCREEN: The auxiliary screen allows the tech to choose from an assortment of HVAC test parameters they want to view while performing various HVAC applications. This screen also allows a variety of test to be done simultaneously. 1050X KIT
1050X-NO KIT
www.imrusa.com 3634 Central Ave. St. Petersburg, Fl 33711 * Phone: 727‐328‐2818 * 1‐800‐RING‐IMR * Fax: 727‐328‐2826 Email: [email protected] Page 3 of 3 
Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS DRYER
IMR 500
FLUE GAS DRYER
This device is for the cleaning of gases and is
suitable for use in conjunction with all gas
measuring and analysis instruments.
It is encased in a handy portable case. It is
especially designed for use with the IMR 2000
P/ IMR 3000 P gas analyzer.
The dust free gas is led directly to the IMR 500
P via heated tube without being cooled.
Leading the gas through a tube, the outside of
that has dry gas flowing over it, performs the
selective and continuous removal of water
vapor. The water vapor permeates the tube
and is drown off by the dry gas while the other
constituents remain. At the end of the
operation dry and dust free gas is left.
IMR 500 P IN A 19" RACK SYSTEM
FEATURES
TECHNICAL DATA
Gas drier IMR 500 P
Capacity : 2.5 l/min
Heated gas tube, including filter and gas sampling probe
Heated gas tube 5 ft. (1.5 m):
Connection tube between drier and measuring instrument
Temperature regulation: 338°F (170°C)
Power cord
Power supply: 110 V / 60 Hz (230 V / 50 Hz)
User manual
Dimensions : 14.6 x 7.3 x 13.4 in. (370 x 185 x 340 mm)
Weight : 13.2 lb. (6 kg)
THE PRIDE OF THE COMPANY - MADE IN USA -
®
Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
COMBUSTION GAS ANALYZER
IMR 1000
IMR1000-1/,052
IMR 1000
IMR1000-3/,054
The IMR1000 is a hand held pocket size stack gas
analyzer for combustion tests on boilers, burners, etc.
The IMR1000-1/,05-2 have up to two sensors with
a 2-line LCD while the IMR1000-3/,05-4 have a
4-line LCD and come with up to 3 sensors.
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
Up to 3 sensors
Small and rugged
Easy to operate
Light weight
Memory
Infrared Interface for printer
Protective boot with integral magnet
Large backlit display
Reliable Technology
Easy to service
Displayed parameter can be chosen
Measured parameters:
„ Oxygen O2
„ Carbon Monoxide CO
„ Carbon Monoxide CO (ambient)
„ Nitric Oxide NO
„ Flue-Gas Temperature
STANDARD
; Enclosure:
;
;
;
Calculated values:
„ Combustion Efficiency
„ Excess Air
„ Carbon Dioxide
„ CO corrected to 0% O2
; Zero point calibration:
Rugged plastic case with protective boot
and magnet
Fuels:
Natural Gas, Propane, Butane, LPG,
Light Oil
Measuring units:
ppm, mg/m3
Service program:
Check of all values
;
;
;
;
; Gas sampling probe:
Max. 60 seconds
Battery:
> 8 hrs
Languages:
English, German, French, etc.
Condensation trap:
Integrated filter
Operating Conditions
32-104°F / 0-40°C;
10-90% rel. humidity, noncondensing
THE PRIDE OF THE COMPANY - MADE IN USA -
;
;
;
Thermocouple Type K;
∅ 0.25"/ 6mm;
Length 9"/220mm;
Hose 9'/3m
Power Supply:
4 x AA
Weight
2.2lbs / 1kg
Dimensions
7.9x1.8x3.5” /
200x45x90mm
© Copyright 2010 IMR Environmental Equipment, Inc.
®
Environmental Equipment, Inc.
IMR1000 Specifications
Features
Worklight
Low battery indicator
Individual print-out reports
Rotary selector
Memory positions (various tests)
Infrared printer port
Backlit display
Boot with integral magnet
User programmable headers
Time & date stamp
1 yr warranty
Temp Measurement
Flue Temp Range (T13/4)
Inlet Temp Range (T2 3/4)
Inlet Temp Range (Ambient)
Net Temp (∆T)**
Resolution
Flue (T1, Inlet T2, & Net ∆T) Accuracy
Inlet Temp Ambient Accuracy
Gas Measurement
Oxygen
O2 Resolution/Accuracy
Carbon Monoxide (2/3/42QO\)
CO Resolution/Accuracy
(IMR1000-2/3/4 Only)
Carbon Dioxide**
CO2 Resolution/Accuracy
Efficiency**
Efficiency Resolution/Accuracy
Excess Air**
Excess Air Resolution/Accuracy
CO/CO2**
CO/CO2 Resolution/Accuracy
Nitric Oxide
Nitric Oxide Resolution/Accuracy
IMR1000-1/,05
IMR1000-3
IMR1000-4
✔
✔
✔
✔
179
✔
4 Lines
✔
✔
✔
✔
✔
20
✔
2 Lines
✔
✔
✔
✔
✔
✔
✔
✔
179
✔
4 Lines
✔
✔
✔
✔
32 ~ 1112°F / 0 ~ 600°
20 ~ 2400˚F / -29 ~ 1315˚C
-
32 ~ 1112˚F / 0 ~ 600˚C
32 ~ 112˚F / 0 ~ 50˚C
1˚F/˚C
±[0.3% rdg +5˚F(3˚C)]
±[0.3% rdg +1˚F(1˚C)]
0 ~ 21%
0.1% / ±0.2%*
0 ~ 1000 ppm
1 ppm/±10 ppm < 100 ppm*
±5% reading
0 ~ 30%
1.0%/±0.3% reading
0 ~ 99.9%
0.1%/±1.0% reading
0 ~ 250%
0.1%/±0.2% reading
-
32 ~ 112˚F / 0 ~ 50˚C
20 ~ 2400˚F / -29 ~ 1315˚C
0.1˚F/˚C
±[0.3% rdg +3.6˚F(2˚C)]
±[0.3% rdg +1.8˚F(1˚C)]
0 ~ 21%
0.1% / ±0.2%*
0 ~ 4000 ppm
1 ppm/±10 ppm < 100 ppm*
±5% reading
0 ~ 30%
1.0%/±0.3% reading
0 ~ 99.9%
0.1%/±1.0% reading
0 ~ 250%
0.1%/±0.2% reading
0 ~ 0.999%
0.0001%/±5% reading
-
0 ~ 21%
0.1% / ±0.2%*
0 ~ 4000 ppm
1 ppm/±10 ppm < 100 ppm*
±5% reading
0 ~ 30%
1.0%/±0.3% reading
0 ~ 99.9%
0.1%/±1.0% reading
0 ~ 250%
0.1%/±0.2% reading
0 ~ 0.999%
0.0001%/±5% reading
1 ppm/±2 ppm < 30 ppm*
±5 ppm > 30 ppm
Pressure (Differential)
Range ±0.2mBar 0.08”wg
Range ±1mBar 0.4”wg
Range ±80mBar 32”wg
Dimensions
Weight
Handset
Probe
Operating temp
Battery
Warranty
0.001mBar/±0.005mBar ±0.002”wg
0.001mBar/±0.03mBar ±0.01”wg
0.01mBar/±3% reading
2.2lbs. with boot
7.9 x 1.8 x 3.5”
11.8 x 0.25 x 9.4” stainless steel shaft, type K thermocouple (9’ hose)
0 to 40˚C/10% to 90% Relative Humidity non-condensing
x4 “AA” cells / 12 hour life typical with Alkaline “AA” cells
1 year limited warranty
0.001mBar/±0.005mBar ±0.002”wg
0.001mBar/±0.03mBar ±0.01”wg
0.01mBar/±3% reading
Pre-Programmed Fuels
Natural Gas, Propane, Butane, LPG, Light Oil
*Measures **Calculates
© Copyright 2010 IMR Environmental Equipment, Inc.
®
Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
OPTIONAL
AC adapter with rechargeable batteries
Infrared printer
Soft carrying case
Hard carrying case
1000-1
O2, condensation trap, gas sampling probe, batteries, manual
1000-2
O2, CO, condensation trap, gas sampling probe, batteries, manual
1000-3
O2, CO, draft, condensation trap, gas sampling probe, batteries, manual
1000-4
O2, CO, NO, draft, condensation trap, gas sampling probe, batteries, manual
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPANY - MADE IN USA © Copyright 2010 IMR Environmental Equipment, Inc.
Product Specification of:
IMR FLOWMETERS
Environmental Equipment, Inc.
KEY FEATURES
• Available for use with both water and air
• Flow tube and body molded of high
high-impactpolycarbonate
• Precision adjusting valve for accurate, leak
leak-free flow control
• Molded High Impact Polycarbonate
• High Quality Construction
• Economy Combined with Accuracy
• Monitor or Control Air and Water Flows
• Flow Ranges: Air 50 CCM to 100 LPM Water 4 CCM to 40 GPH
• Supplied with Easy-to-Read
Read 10:1 Turn Direct Reading Scales
• Standard Black Body, Custom Colors Available upon Request
ITEM #: FLOW CONTROLLER
ITEM #: 90700
SPECIFICATIONS
Accuracy:
Ambient Pressure:
Floats:
Temperature:
Pressure:
Fittings:
Valve:
(optional)
Seal Material:
± 4% Full Scale
Polycarbonate
Black glass, Carbide,
Stainless Steel or Aluminum
150º F / 65º C Maximum
100 PSI 6.9 Bar Maximum
Brass or Stainless Steel
Brass or Stainless Steel
Cartridge Type
Buna-N w/ Brass Fittings
IMR® Environmental Equipment, Inc.
3634 Central Ave. St. Petersburg, FL 33711
Phone: 727-328-2818
FAX: 727-328-2826
E-Mal: [email protected]
Page 1 of 2
www.imrusa.com
DESCRIPTION
Molded of high-impact resistant polycarbonate
these flowmeters are available in customized
ranges. These units are supplied with scales in LPM
Air, SCFH Air, CCM Water and GPH Water, all with
10:1 turn down ratios. The IMR Flow meters has
been designed to maintain maximum pressures to
100 psig and temperatures to 150°F. These
economically engineered units have been designed
to provide the highest quality with precision
accuracy. These flowmeters are fitted with 1/8"
FNPT inlet and outlet connections. An optional
inlet or outlet control valve can be specified.
*Specifications subject to change without prior notification.
Contact IMR for latest data.
IMR® Environmental Equipment, Inc.
3634 Central Ave. St. Petersburg, FL 33711
Phone: 727-328-2818
FAX: 727-328-2826
E-Mal: [email protected]
Page 2 of 2
www.imrusa.com

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
NEW
ELECTRONIC MANOMETER
EM200
NEW
EM200
Small and easy to use manometer with dual inputs.
¾
Ruggedized with sturdy metal fittings
¾
Rubber boot with built-in magnet
¾
Min/Max function
¾
Data hold
¾
Auto power off
¾
Large, backlit display
¾
Latest technology
SPECIFICATIONS
Power Supply
9V Alkaline battery
Battery life
Approx. 40 hours
Sensor
Solid state
Range
-60” to +60”WG
-150 to 150mBar
Accuracy
+/- 1.5% (full scale)
Resolution
0.01” : -9.99”WG to +9.99”WG
0.1” : < -10”WG
0.1” : > +10”WG
Dimensions
5” x 2.7” x 1.4”
(130 x 69 x 34mm)
Ambient conditions
32 to 102°F (0-40°C)
10-90% RH (non condensing)
ACCESSORIES
Soft Carrying Case
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
© Copyright 2012 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
NEW
DIGITAL THERMOMETER
DTK2
NEW
DTK2
The DTK2 digital thermometers accept type K probes to
accommodate your existing process technology. The
DTK2 allows you to measure two inputs simultaneously.
Dual input with differential (T1 – T2)
Min / Max capture (T1 & T2)
Temperature in °C or °F
Magnetic mount
Large display
Latest technology
SPECIFICATIOS
Power Supply
9V Alkaline battery
Probes
Type K thermocouple
Range
Type K
-328 to 2498°F (-200 to 1370°C)
Accuracy
+/- 0.1% reading + 2.0°F (+1.0°C)
Resolution
0.1°F, 1°F (0.1°C, 1°C)
ACCESSORIES
Standard bead probes
Surface probes
Right angle probes
Soft carrying case
Hard carrying case
IPUT OPTIOS
STADARD
Model
Inputs
9V battery
DTK2
Two
2 Standard bead probe, Type K
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPAY - MADE I USA © Copyright 2003 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. — St. Petersburg, Florida 33711 — Phone 727-328-2818 — 800-RING-IMR — FAX 727/328-2826 — E-mail: [email protected]
www.imrusa.com
NEW
NEW
DIGITAL THERMOMETER
DT301 / DT302 / DT304
DT301 / DT302 / DT304
The DT301 / DT302 / DT304 digital thermometers accept
type J, K, T or E probes to accommodate your existing
process technology. Its backlight displays are easy to
read, even in low-light areas. The DT302 allows you to
measure two inputs simultaneously. The DT304 allows
you to measure four inputs simultaneously.
Accepts K, J, T, or E thermocouples
Time-stamped multifunction record
Relative function displays temperature change
Differential temperature (DT302 / DT304)
Temperature in °C or °F
Large, backlit display
Latest technology
SPECIFICATIOS
Power Supply
2x AAA Alkaline 1.5V battery
Probes
Type K, J, T or E thermocouple
Range
Type K
-328 to 2498°F (-200 to 1370°C)
Type J
-346 to 2192°F (-200 to 1200°C)
Type T
-418 to 752°F (-250 to 400°C)
Type E
-238 to 1832°F (-150 to 1000°C)
Accuracy
+/- 0.1% reading + 1.0°F (+0.5°C)
Resolution
0.1°F, 1°F (0.1°C, 1°C)
ACCESSORIES
Standard bead probes
Air probes
IPUT OPTIOS
Model
Inputs
DT301
One
DT302
Two
DT304
Four
Surface probes
Liquid probes
STADARD
Right angle probes
2x AAA battery
Soft carrying case
Standard bead probe, Type J
Hard carrying case
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
THE PRIDE OF THE COMPAY - MADE I USA © Copyright 2003 IMR Environmental Equipment, Inc.

DAFM3
Digital Air Flow Meter
SIX HVAC/R PARAMETERS IN ONE!
Measures:
• Air Velocity
• Temperature
• Relative Humidity
Calculate:
• Wet Bulb
• Dew Point
• Air Volume
Protective Twist Cap
for Sensor
3634 Central Ave. St. Petersburg Fl, 33711 * Phone: 727 -328-2818 or 1 800 – RING- IMR Fax: 727-328-2826
E-mail: [email protected] * Web: www.imrusa.com
DAFM3 • Digital Air Flow Meter
The DAFM3 Anemometer/Psychrometer meter is
designed with 6 HVAC/R must have parameters in one
instrument. These are included in a portable battery
operated instrument for measuring Relative Humidity, Air
temp., Dew Point, Wet Bulb, Air Velocity and Air Volume.
The sensor is built into the remote fan and is specially
protected by a twist cap. While in operation, open the
cap for accurate temperature and relative humidity
readings.
The DAFM3
has the following features:
• Measures Air Velocity, Temperature and Relative Humidity
• Calculate Wet Bulb, Dew Point, and Air Volume (CFM, CMM)
• Protective twist cap for temperature/humidity sensor
• 8-Point Average for Air Velocity
• 60 Second Average for Air Volume
• Total Volume from multiple outlets
• Large LCD digital display
• Professional remote vane
• English/Metric scales
• Low battery indication
• Fast response
• Microprocessor circuitry for reliability
• Auto Power Off selectable
• Powered by 1 9V battery
• One year limited warranty
Distributed By:
Specifications
Temperature
-4˚ to 140˚F (-20˚ to 60˚C)
Accuracy: +1˚F (+0.6˚C)
Resolution: 0.1˚F (0.1˚C)
Relative Humidity 0 to 100% RH
Accuracy: +3% at 10 to 60% RH
+5% at other range
Resolution: 0.1%
Dew Point
-90˚ to 158˚F (-68˚ to 70˚C)
Accuracy: +3% at 10 to 60% RH
+5% at other range
Resolution : 0.1%
Wet Bulb
-7.6˚ to 158˚F (-22˚ to 70˚C)
Temperature
Accuracy: +3% at 10 to 60% RH
+5% at other range
Resolution : 0.1%
Air Velocity
0.3 yo 35 m/s (1 to 114 ft/s)
Accuracy: +5%
Resolution : 0.1%
Air Volume
0 to 99999 m3/s (0 to 99999 cfm)
Accuracy: +5%
Resolution: 0.1(0 - 9999.9) or
1 (10000 - 99999)
Power
(1) 9V Alkaline battery or
9V > 200mA adapter
Dimensions
Meter: 175 x 70 x 33 mm
Vane: 170 x 77 x 40 mm

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
NEW
COMBUSTIBLE GAS LEAK DETECTOR
CD200
NEW
CD200
The CD200 is small, easy to use and has a 18” long
flexible gooseneck with a bright LED tip to find
combustible gas leaks in tight areas.
¾
¾
¾
¾
¾
¾
¾
¾
¾
Adjustable tick rate to locate leaks quickly and easily
Visual leak detection by LED indicators
Separate user adjustable alarm for predetermined
level detection
Precision sensor detects even the smallest leaks
Red LED located on the tip to illuminate the search
area
Fast response time (<2 seconds to 40%LEL)
Small and light
Earphone
Impact resistant storage case
Partial list of gases detected:
Acetone, Alcohol, Ammonia, Butane, Gasoline, Halon,
Hyydrogen Sulfide, Industrial Solvents, Jet Fuel, Laquer
Thinners, Naphta, Natural Gas, Propane, Select
Refrigerants ... and more
SPECIFICATIONS
Power Supply
4 AA Alkaline batteries
Battery life
Approx. 12 hours
Sensor
Solid state semiconductor
Sensitivity
< 50ppm Methane
Warm-Up
Approx. 1 minute
Response time
< 2 seconds (to 40%LEL)
Recovery time
< 4 seconds (from 40%LEL)
Dimensions
8.6” x 3.1” x 2.3” (220x80x58 mm)
Gooseneck
18” (45cm)
Level Indicators
Audible: adjustable tick
Replacement Sensor Cap
Visual: Six LEDs (green to red)
Earphones
ACCESSORIES
Replacement Sensor
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
© Copyright 20 IMR Environmental Equipment, Inc.

Environmental Equipment, Inc.
3634 Central Ave. · St. Petersburg, Florida 33711 · Phone 727-328-2818 · 800-RING-IMR · FAX 727/328-2826 · E-mail: [email protected]
www.imrusa.com
NEW
COMBUSTIBLE GAS LEAK DETECTOR
CD100A
NEW
CD100A
The CD100A is designed to detect combustible gas leaks
in residential and small commercial applications.
It is small, easy to use and has a 18” long flexible
gooseneck for hard to reach areas.
¾
¾
¾
¾
¾
¾
¾
¾
¾
Simple adjustable tick rate increases as the sensor tip
approaches a leak
Audio and visual tick rate, fully adjustable
Easy one hand operation
Long 18” (45cm) gooseneck for hard to reach areas
‘Tip light’ in sensor cover illuminates the area of the
leak
Rubber boot protects instrument
Sensor provides accurate detection
Headphone jack
Separate battery compartment for quick and easy
battery replacement
Partial list of gases sensed:
Acetone, Alcohol, Ammonia, Benzene, Butane,
Gasoline, Halon, Hyydrogen Sulfide, Industrial Solvents,
Jet Fuel, Laquer Thinners, Methane, Naphta, Natural Gas,
Propane,Refrigerants, Toluene ... and more
SPECIFICATIONS
Power Supply
9V Alkaline battery
Battery life
5 hours typical use
Sensor
Solid state semiconductor
Sensitivity
50 ppm
Dimensions
8” x 4” x 1.5” (200x100x38 mm)
Gooseneck
18” (450mm)
Tick adjustment
Fully adjustable thumbwheel
Tick indication
Flashing LED
ACCESSORIES
Replacement Sensor
Replacement Sensor Cap
Headphones
Hard Carrying Case
IMR Environmental Equipment, Inc. reserves the right to adopt technical modifications without prior notice.
© Copyright 2012 IMR Environmental Equipment, Inc.