Flyer NP75-NPL75 Hydrant

Transcription

Flyer NP75-NPL75 Hydrant
M-NPL75
SafeWater Hydrant
Non-Pollutible, Sanitary
SafeWater HYDRANT
M-NPL75
• Full Flow - NO restrictions, NO Venturi!
• ASSE 1057 certified & registered
• ASSE 1011 compliant vacuum breaker • ASSE 1052 compliant vacuum
breaker optional
• Empties storage cavity upon next use
• Lockable lever handle or wheel handle
• Easily serviced from above grade with
proper equipment
• NO cross-connections
• NO chance of groundwater contamination
M-NP75
SafeWater Hydrant
with Wheel Handle
The right need-specific hydrants
for campgrounds, parks and any
area requiring clean water!
Always check local codes for compliance
U.S. Patent US7,234,479 B2
Certified
by:
PO Box 3527 City of Industry, CA 91744 USA
P 800-453-7465 F 626-855-4860
murdock-supersecur.com
A member of Acorn Engineering’s Family of Companies
SafeWater Hydrants - M-NPL75 and M-NP75
Exclusively from Murdock-Super Secur
Non-Pollutible, Sanitary Supply Hydrant
M-NP75 ASSEMBLY
WITH WHEEL HANDLE (shown)
FEATURES
Handle top 25”to
finished grade level
Patent - U.S. Patent US7,234,479 B2
Inlet - 3/4” female NPT
Accessible lever handle
operates with 180°
rotation between full open
and closed positions
(See valve assembly inset)
Working Pressure - 25-80
Outlet - 3/4” hose thread
• ASSE 1011 Compliant Vacuum Breaker
Nozzle center 18” to
finished grade level
Handles - Lockable lever handle
or wheel handle
Flow Rate - 4.5 gal/min at 25 psi
( ASSE 1052 Compliant Vacuum Breaker Optional )
(with ASSE 1011 compliant vacuum
breaker)
• Field serviceable
Maintenance - Inspect annually
• Air By-Pass Valve for Positive Drainback
• Serviceable from above grade
Finish - Painted
Exclusive Valve Assembly
Air by-pass
ACTIVATION
DELIVERY
CLOSED
Activation purges
stored water in less
than 1/2 second
Drainback cavity
(8 oz maximum
based on 6 ft bury)
Valve in
closed position
Piston Assembly-Normal
service includes replacement
of standard o-rings and
food-grade lubricant
Valve assembly- Normal service
includes replacement of tapered
faucet washer and one o-ring
Frost Line
6 1/2” Valve body
with storage cavity
M-NPL75
ACCESSIBLE HANDLE
(With padlock hole)
Padlock not included
Full on
position
Hold open
setting
Full closed
position
(lockable)
General Specifications - M-NPL75 and M-NP75
The M-NPL75/M-NP75 is sealed against surface and below grade
contamination. No cross-connections. Positive displacement action evacuates
the stored water that is held below the frost line (6 feet maximum bury)
through the riser pipe and exiting at the 3/4” outlet nozzle.
Outlet is protected by use of an ASSE 1011 compliant vacuum breaker that
remains attached during the use of a hose. Positive drain back will occur by use
of an air by-pass valve even when hose is attached.
No venturi is used. Positive flow is maintained at 4.5 gallons per minute at 25
psi inlet water. Best operation at 40-60 psi.
Field serviceable from above grade without digging for operating parts.
Recommend a shut-off device prior to the hydrant so that maintenance may be
done without shutting down entire area. All serviceable parts are available from
Murdock Super Secur.
All components are made of brass, stainless steel, or neoprene. All wear parts
are lubricated with food grade materials. Lead-free castings are used in all
waterways.
3/4” inlet with a 3/4” hose outlet standard.
Optional handles (Wheel, Lever). Lever handle standard full-open or adjustable
to automatic shut-off.
Potable, freeze resistant, year round use, post type hydrant.
ANSI/NSF-61 and ASSE 1057 Certified.
Product is