• SAVE INSTALLATION TIME AND AVOID CALL-BACKS •
• READ THIS MANUAL BEFORE MOUNTING COLLECTORS •
INSTALLATION MANUAL FOR
AQUATHERM INDUSTRIES
SOLAR COLLECTORS
USING STAINLESS STEEL
MOUNTING HARDWARE
MANUAL CONTENTS
This manual provides a detailed step-by-step
procedure for the installation of an Aquatherm
Industries Solar Pool Heating System. If the directions are followed correctly and only recommended
Aquatherm Industries hardware and components
are used, the installed system should provide years
of trouble free service, savings, and enjoyment.
CAUTION: SOLAR COLLECTORS ARE OFTEN INSTALLED
ON THE ROOFS OF BUILDINGS. UNLESS YOU ARE VERY
FAMILIAR WITH WORKING ON ROOFS AND HAVE THE
PROPER LADDERS AND SAFETY EQUIPMENT FOR
SUCH WORK, YOU SHOULD HIRE SOMEONE WITH THE
NECESSARY EXPERIENCE TO DO THE INSTALLATION.
FAILURE TO OBSERVE SAFE PRACTICES ON A ROOF OR
OTHER ELEVATED STRUCTURE MAY RESULT IN FALLING,
LEADING TO SERIOUS INJURY TO YOU.
Figure 1
MOUNTING
COMPONENTS
DIAGRAM
MOUNTING COMPONENTS
This section provides descriptions and part numbers of the
Aquatherm Industries Installation Kits required for each
solar pool heating system. The mounting location of each
kit component is shown by the corresponding circled number in the ‘Mounting Components’ diagram, shown above.
2 The System Kit (Part #12135-1 for 1 1/2” kit; #12135-2
for 2” kit) contains additional hold-down hardware, connection parts and adapters needed to complete water connections from the collectors to the system feed and return line.
The pipe adapters that connect the system piping to the collectors are high temperature CPVC. The system check
valve is 1 1/2” - 2” PVC. Installation and homeowner manuals are also included. Use one (1) kit per system.
1 The Collector Installation Kit (Part #12034-1 for 1 1/2” kit;
#12034-2 for 2” kit) contains the parts needed to fasten a single
solar collector to a supporting surface and to make water connections from one collector to another. Hold-down strap is not included and must be ordered separately Use one (1) kit per collector.
Part No Qty 1 1/2” Qty 2”
Description
10008-1 1
10008-2 __
50006
2
60691-1 2
60648-2 __
60003-1 4
60003-2 __
Outlet header hold-down bracket assembly
Outlet header hold-down bracket assembly
Hold-down strap bracket
Collector connector hose (3 3/4” long)
Collector connector hose (3 3/4” long)
Hose clamp, stainless steel
Hose clamp, stainless steel
__
1
2
__
2
__
4
2
Part No Qty 1 1/2” Qty 2”
Description
10003-1
10003-2
10008-1
10008-2
10011
30061-1
30061-2
30089-1
30089-2
50006
60691-1
60649-2
60003-1
60003-2
60019-2
19001
19697
Vacuum Relief Valve
Vacuum Relief Valve
Outlet header hold-down bracket assembly
Outlet header hold-down bracket assembly
Hold-down strap clamp assembly
End cap
End cap
Pipe adapter
Pipe adapter
Hold-down strap bracket
System connector hose (7” long)
System connector hose (7” long)
Hose clamp, stainless steel
Hose clamp, stainless steel
Check Valve (1 1/2” & 2”)
Installation Manual
Owner’s Manual
1
__
1
__
4
1
__
2
__
2
2
__
4
__
1
1
1
__
1
__
1
4
__
1
__
2
2
__
2
__
4
1
1
1
5 The Row Spacer Kit (Part #12017-1 for 1 1/2” kit; #12017-2
for 2” kit) is used when a row of collectors must be interrupted by
a space to allow for obstructions such as a chimney or roof vent.
It contains the hardware needed to space around any width
obstructions by connecting appropriate lengths of PVC pipe to
the pipe adapters at the inlet and outlet headers of the two collectors on either side of the obstructions. Use when required.
2A The Optional Supplemental System Isolation Kit
(Part #12033-5) includes a 1 1/2” - 2” PVC union ball
valve and a 1 1/2” -2” PVC check valve to permit manual isolation of the solar system from the pool or spa filtration system. Use one (1) kit per system.
3 Hold-Down Strap is required to secure collectors to
the mounting surface. Use strap 10035-1 (54’) for rows of
up to 6 collectors or strap 10035-2 (107’) for rows of up to
12 collectors. Available in bulk, 1400 ft. roll. Part #10040.
Part No Qty 1 1/2” Qty 2”
Description
10008-1
10008-2
10011
30089-1
30089-2
50006
60691-1
60648-2
60003-1
60003-2
Outlet header hold-down bracket assembly
Outlet header hold-down bracket assembly
Hold-down strap clamp assembly
Pipe adapter
Pipe adapter
Hold-down strap bracket
Collector connector hose (3 3/4” long)
Collector connector hose (3 3/4” long)
Hose clamp, stainless steel
Hose clamp, stainless steel
1
__
4
4
__
2
2
__
4
__
__
1
4
__
4
2
__
2
__
4
6 Double Hole Outlet Header Bracket (Part #50069) may
also be used to terminate a strap run in high wind areas where
extra hold-down strength is required.
4 The Add-A-Row Kit (Part #12043-1 for 1 1/2” kit; #120432 for 2” kit) is used when more than one row of collectors is to
be installed. Use one (1) kit for each collector row after the first.
Part No Qty 1 1/2” Qty 2”
Description
10003-1
10003-2
10008-1
10008-2
10011
30061-1
30061-2
30089-1
30089-2
50006
60691-1
60649-2
60003-1
60003-2
Vacuum Relief Valve
Vacuum Relief Valve
Outlet header hold-down bracket assembly
Outlet header hold-down bracket assembly
Hold-down strap clamp assembly
End cap
End cap
Pipe adapter
Pipe adapter
Hold-down strap bracket
System connector hose (7” long)
System connector hose (7” long)
Hose clamp, stainless steel
Hose clamp, stainless steel
1
__
1
__
4
1
__
2
__
2
2
__
4
__
__
1
__
1
4
__
1
__
2
2
__
2
__
4
7 Aluminum Mounting Bracket & Header Clamp Assembly
The Aluminum Header Bracket Assembly (Part #30171-1 for
1 1/2” only) is used as supplemental outlet header mounting in
conjunction with the Outlet Header Hold-Down Bracket assembly
(Part #10008-1). The bracket is designed for installations that
require more flexibility for the outlet header mounting hardware
location, such as barrel tile roofs or installations that require additional mounting hardware to be anchored into rafters or beams.
The Aluminum Header Clamp Assembly (Part #10117-1 for
1 1/2”; #10117-2 for 2”) is used the same as the Aluminum
Header Bracket (Part #30171-1) and allows for collector
removal without disturbing the roof penetrations.
3
8 Header Inserts (Part #50055-1 for
1 1/2”; #50055-2 for 2”) are used
in special situations where
unusually high stagnation
temperatures are expected,
such as in a desert climate
or where abnormally high
system pressures may occur.
Use four (4) inserts per collector.
MOUNTING THE SOLAR COLLECTORS
Refer to Figure 2 throughout this section. When mounting
the collectors, always make provisions for inlet connections at the bottom header and outlet connections at the
top. The outlet headers must be pitched a vertical distance of at least 8” (20cm) above the inlet headers to
assure uniform flow and proper drainage to prevent
freezing. Plan the collector location to allow at least one
foot on all sides of the row of collectors for mounting
brackets and piping. The outlet pipe for each row of collectors must be connected diagonally opposite the inlet
pipe.
9 The Optional Supplemental High Wind Area
Collector Hold-Down Kit (Part #12035-1 for 1 1/2”,
#12035-2 for 2”) used in addition to the basic collector
installation kit in regions where high winds are prevalent.
Requires twice the amount of hold-down strap.
TABLE A
DISTANCE BETWEEN PANEL
HEADERS AND STRAPS
Collector
Panel Size
in feet
_________
12
10
8
6
4
Collector
Collector
(A) Distance (B) Distance
inches
(cm) inches
(cm)
_________
_________
60 (152)
48 (122)
36 (91)
24 (60)
_____
16 (40)
ASSEMBLY ON
ROOF DIAGRAM
Figure 2
4
1) Determine the position of the last outlet header holddown bracket for the row of collectors. Mark this point on
the roof. The collector outlet headers will be located approximately 1” (25mm) below this mark. Refer to Figure 3.
Figure 5
Figure 3
outlet header bracket chalk line, snap another chalk line
parallel to this line using the “A” dimension. The “B”
dimension is the same for all collector sizes, which is 16”
(40cm) up from the outside of the bottom header and can
be measured after the collectors are installed. Wait to
install the hold-down strap brackets until after the collectors are installed so as not to damage the collectors
when you are bringing them to the roof for installation.
2) Using this point, snap a chalkline to the opposite end
of the row. Slope this line down the roof toward the
inlet approximately 1” (25mm) for each 6 collectors in
the row. Using a 1/8” (3mm) drill bit (for 1/4” (6mm) diameter screws) drill a hole for the first outlet header bracket
on the first roof mark. Measure up 1” on center from the
first pilot hole and drill pilot hole for second screw.
Repeat this process all along the chalkline for the total
number of collectors to be installed.
5) Bring the first collector to the roof and slip the proper
hoses over both ends of the inlet and outlet headers on
the last return collector. Make sure that the side of the
collector with the serial number label on it is facing down.
The long hoses (7”) go on the outlet of the last collector
and the inlet of the first collector. Push UP TO the hose
locating shoulder, but NOT OVER it. Locate a hose
clamp 3/8” (10mm) from the end of the hose in order to
center it on the header groove. This clamp must face up
so as to be accessible for tightening and will not rub
against the mounting surface. Make sure you securely
tighten each clamp with a nutdriver. If a nutdriver is not
available, a ‘hex’ wrench or screwdriver will suffice. THE
HOSE CLAMPS MUST BE LOCATED OVER THE
GROOVES IN THE HEADER.
Figure 4
6) Position the collector on the roof so that the center of
the outlet connection hoses are directly beneath the
secured outlet header brackets and slip the bracket holddown clamps over the connection hoses. Lightly tighten
the clamp around the header hose. Refer to Figure 5.
Continue to install all the collectors in the array, coupling
them side to side.
3) Inject a generous amount of high quality sealant into
each hole and onto the surrounding roof surface. Bolt all
the outlet header hold down brackets to the roof as
shown in Figure 4.
7) If the Aluminum Header Clamp Assembly is to be
used for supplemental mounting hardware, install them
after both the outlet header brackets and the collectors
have been installed.
4) Locate the hold-down strap bracket holes using the
information in Figure 2, Table A. Measuring from the top
5
7) Proceed to the lower chalk line previously snapped on
the roof for the hold-down strap brackets. Mark a hole 2”
(5cm) to the side of the first collector and continue marking holes on the chalkline centered exactly between the
absorber surfaces until you reach the last collector.
Mark the last hole the same 2” (5cm) to the side of the
last collector. Drill a pilot hole and apply sealant at each
of these locations. Bolt the hold-down strap brackets on
the roof. Refer to Figure 6. It is OK to step on the collectors as long as you stay one foot away from the top
and bottom headers. Mark the holes for the bottom holddown strap by measuring up 16” (40cm)from the outside
of the bottom header and again centering them between
the absorbers and 2” (5cm) away from the first and last
collector.
Figure 8
both slots in the bracket located on the other side of the
collectors. Pull the straps taut against the face of the
collector. Repeat this procedure for the remaining holddown strap. Refer to Figure 9.
Figure 9
Figure 6
8) Install the vacuum relief valve in the outlet header of
each row. This will be located at the opposite end of the
row that is connected to the collector outlet pipe. Refer
to Figures 2, 11, and 12.
9) Install an end cap in the inlet header of each row,
opposite the end that is connected to the collector inlet
pipe. Refer to Figures 2, 10, 11, and 12.
10) INSPECT THE INSTALLATION AND CHECK ALL
CLAMPS FOR PROPER POSITION AND TIGHTNESS.
Installation Over Roof Vent Pipes
Slip one end of a hold-down strap through the slot in the
hold-down strap bracket at the end of the row, then through
the strap clamp and out through the other slot in the holddown bracket. Pull about 3” (7-8cm) of the strap through
Collector models 10001 and 10204 with intermittent sonically welded plates can be installed over or around different diameter roof vent pipes or other obstructions up
to 2” (63mm) in diameter. After snapping the top chalk
lines but before marking and pre-drilling for your outlet
header brackets, locate the seam in the collector nearest
to where the vent pipe is to come through. Separate by
pulling up on top plate, and pushing down on the lower
plate. Should the vent pipe protrude near a sonic tack
weld, it will have to be cut apart. Using a sharp utility
knife, cut through the weld while pulling the two plates
apart. Lay the collector over the vent pipe, keeping the
vent pipe at least 12” (30.5cm) away from a header. It
will be easier to complete an installation by mounting this
collector first and then working away from it.
Figure 7
and bend it back toward the clamp. Refer to Figure 7.
Slip the loose end of the strap through the strap clamp
and pull it tight. Clamp screw (A) should be tightened
securely, but not over-tightened to the point where the
clamp is distorted. Refer to Figure 8. Bring the remaining strap end across the collector face, passing through
If you have the installation flexibility it is easier to locate
vent pipes up to 2” between adjacent collectors.
6
Whenever there is more than 40 gpm (151.6l ) required
flow rate to the collectors or more than 100’ (12m) of piping used in a system, install 2” (63mm) piping to and from
the collectors.
With a roof vent pipe of 3” (8cm) in diameter, the collectors can be positioned on either side of the vent. Two system connector hoses (Part #60691 or 60649-2) can be
employed to couple the collectors together for vent pipes
or other obstacles up to 7” (17cm) in diameter. Mark your
51” (1.3m) centers wherever the outlet header brackets
‘fall’ on the upper chalk line. With obstructions of over 7”
(17cm), such as attic fans and skylights, lay out the collectors on either side of the obstruction using a Row
Spacer Kit (Part #12017-1 for 1 1/2”; #12017-2 for 2”).
Piping to and from the collectors should be the same type of
plastic piping and fittings approved for use with swimming
pool filters and pumps. It is recommended to always use
Schedule 40 PVC pipe and fittings. Although PVC pipe is
generally white, black is also available but may be difficult to
find locally. If for aesthetics black pipe is desired it can always
be painted black. Use a PVC cutter or a PVC wide-blade saw
(not a hacksaw) for cutting pipe. It is important to use both a
quality cleaner/primer and solvent in gluing a PVC joint.
Finally, use a cloth while either gluing or painting to keep the
job a clean one. Piping should also be supported at intervals
of 5’ (1.5m) for horizontal pipe and 8’ (2.5m) for vertical pipe.
Use Aquatherm Industries pipe brackets made from high
strength glass-filled polypropylene. They are available in 1
1/2” (30272-1 black; 30284-1 white) and 2” (30272-2 black
and 30284-2 white).
System Piping
Refer to Figures 10, 11 and 12 throughout this section. The
most common piping configurations use a pressure filter.
The pump draws the water from the skimmer and/or a
main drain, forcing it through the filter and sending it back
to the pool through the return lines.
If a fuel-fired heater or heat pump is installed, it is located
between the collector return line and the return line to the
pool. The pipes to and from the solar collectors are connected to the return line to the pool before the water enters
the fuel-fired heater, if one is used.
VACUUM RELIEF VALVE
SOLAR
COLLECTORS
SOLAR
SENSOR
Figure 10
END
CAP
PLUMBING
SYSTEM
SCHEMATIC
VACUUM
RELIEF VALVE
FLOW
METER
(optional location)
(optional)
OUTLET LINE
THERMOMETER
ELECTRONIC
CONTROL
(optional)
ISOLATION
BALL VALVE
ISOLATION
CHECK VALVE
(optional)
(optional)
HEATER BY-PASS
BALL VALVE
120/240
V-LINE
(optional)
FILTER
WATER
SENSOR
CHECK
VALVE
3-WAY
VALVE
OUTLET
TEE
PUMP
HEATED OUTLET
FROM COLLECTORS
COLD INLET
FROM POOL
7
HEATER
optional)
Manual Systems
Table B
COLLECTOR SIZE
4x12
Recommended flow rate per collector, gpm/l 5.0/18.9
Minimum flow rate per collector, gpm/l
3.0/11.4
Maximum flow rate per collector, gpm/l
10/37.85
Maximum # collectors per row:
1 1/2”10
2”12
Maximum square footage per array: 1 1/2”- 480 sq.ft. /
Pressure Drop, psi@gpm:
1 1/2”- [email protected]
2”- [email protected]
Some systems employ a manual control valve to control
the flow of water thru the solar collectors, although this
may reduce the overall heating capacity of the system. A
manual control valve usually consists of a non-positively
sealed 3-way valve used in place of the motorized valve
as shown in Figure 10. Water continuously flows through
the solar collectors when the filter pump is on, but can be
diverted manually by the pool owner if the pool becomes
too warm or during extended cloudy weather. During a
threat of freezing conditions it can also be diverted, by first
shutting off the pool pump, allowing the collectors to drain,
diverting the 3-way manual valve to the “bypass collector”
position and shutting the isolation valve on the collector
feed line. A lower end cap on the collectors or any of the
connecting hoses can be removed to make sure there is
no standing water in the collectors. The filter pump can
then be re-started to allow for normal pool filtration.
4x10
4x8
4.0/15.1 3.25/12.5
2.5/9.5
2.5/9.5
10/37.85 10/37.85
12
12
12
14
2”- 576 sq.ft.
[email protected] [email protected]
[email protected] [email protected]
uniformly cool to the touch, and there should be no residual air left in the pool return lines. If either of these two
conditions persist, chances are that the flow rates thru
the collectors are inadequate or the system is not properly balanced. A flow meter can be installed in the collector feed line to check on the flow rate. If the flow rates
are within the limits as shown in Table B, then the system may not be properly balanced, especially with systems requiring multiple banks of collectors. Refer to the
following section on Special System Layouts.
Automatic Control Systems
The performance of a solar pool heating system can be
improved with the use of an electronic control and motorized 3-way valve. The control activates the motorized
valve and either sends water thru the collectors for heating
(or nocturnal cooling) or automatically bypasses the collectors when the pool is warm enough or insufficient sunlight
is available. Refer to the manufacturer’s instructions
included with the automatic control you use.
If the flow rate is below the minimum as shown in the
table above, then the pool pump horse power or pipe
size should be increased, or a booster pump installed in
some cases. If the flow rate is excessive (more than 10
GPM/(37.9l ) collector), or if the system pressure is
greater than 30 psi, a bypass line should be installed
between the collector feed and return lines above the 3way valve to prevent problems with the collectors and
connection hoses.
During normal operation of the system when the 3-way
valve is in the ‘bypass collector’ position all the water in the
collectors should drain back through the 3-way valve (nonpositively sealed) when the filter pump shuts off. An alternate way to protect against sudden freezes can be accomplished by running a bypass line (1/8”-1/4”, 3-6mm)
between the collector feed and return line above the isolation valves, if any. It is possible that a small amount of water
may be present in the collectors when a non-positively
sealed 3-way valve is used and the filter pump is on. If a
positively sealed 3-way valve is used, a bypass line as mentioned above is mandatory to allow for collector drainage.
If there is residual air in the pool return lines and the collectors do feel cool to the touch, refer to the section concerning the vacuum relief valve test on page 10.
Optional Isolation Valves
Isolation valves may be installed in the collector piping
so that the pool may be operated while the collectors are
being serviced or during freezing weather. Install a manually operated ball valve in the collector inlet line and a
check valve on the collector return line. Both valves,
available in the Optional Supplemental System
Isolation Kit (Part #12033-1) are made to accept either
1 1/2” or 2” PVC pipe. Make sure that the arrow on the
check valve is pointing away from the collectors, and that
the ball valve and check valve are located close to the
control valve and outlet ‘T’, respectively. For further precautions in warm climates where pools are operated
year round and periodic freezes can occur, a bypass line
(small diameter tubing) can be located above the ball
and check valve so as to prevent any accidental trapping
of water in the collectors by the pool owner. To make
sure no water is left in the collectors for servicing or during freezes, remember that the pool pump should be
shut off, allowing the collectors to drain naturally, before
the optional isolation valves are used.
Other Equipment
Some pools employ an automatic pool cleaner. This
should be plumbed before the control valve to assure
positive flow to the cleaner at all times. If the pool uses
an automatic chlorinator, this should be plumbed after
the outlet tee on the return to the pool.
Flow Rates
In order to receive optimum results from Aquatherm
Industries collectors, the following recommended flow
rates and number of collectors per row should be followed.
When the system is running, all the collectors should feel
8
a large pressure drop. By placing a heater in a by-pass
loop, pump size, and electrical energy requirements may
be reduced.
Special System Layouts
Use a divided system when installing more than the recommended maximum number of collectors per row,
when avoiding roof obstructions, or where limited space
dictates. This provides uniform distribution of water
through all the collectors. If water distribution through the
collectors is non-uniform, the heating capacity of the system will be reduced.
SYSTEM START-UP AND TEST
System Start-up and Checkout for
Automatic Systems
To check out an automatic system for proper operation
turn on the filter system. Set the temperature control to its
highest level. Switch the control to the “flow through collector” mode. The “flow through collector” light should
come on. The 3 way valve will then be sending water thru
the collectors, and air will be purged out of the collectors
into the pool return line for several minutes, and should
then clear. The collectors should feel uniformly cool to the
touch. Switch the control to the “bypass collector” mode.
The corresponding light will go on and the 3 way valve will
be sending water directly back to the pool, bypassing the
solar collectors. After about 5-10 minutes, feel the solar
collectors again. They should have begun to warm up.
Now switch to the automatic mode. If the sun is still shining on the solar collectors, the “flow thru collector” light
should go on again. Adjust the temperature control lower.
WHEN INSTALLING A DIVIDED SYSTEM, THE OUTLET HEADERS FROM EACH OF THE LOWER (OR
CLOSEST) ROWS OF COLLECTORS MUST BE CONNECTED TO THE HIGHEST (OR FURTHEST) POINT IN
THE SYSTEM. Refer to Figure 11 and 12
A divided system requires an Add-A-Row Kit (Part
#12043-1/-2) for each additional row of collectors.
A more complex divided system is shown in Figure 12.
This also illustrates the application of the Row Spacer Kit
to clear a roof obstruction.
Booster Pump System
In some cases, the pool filter pump may not be able to circulate water at a high enough flow rate to allow for proper
collector operation. If so, it may be necessary to replace
the filter pump with a larger one or add a booster pump. If
the pump size is increased, it may also be necessary to
upgrade the filter with one with greater flow ratings.
When you reach the actual temperature of the pool
water, the light will turn off. The flow bypass collector light
will go on again. Move the temperature control to the
desired comfort level. The “flow through collector” light
will go back on. For more detailed information on the system startup, trouble shooting and valve/control installation, follow the manufacturers’ instructions included with
the automatic control system.
Supplemental Gas, Oil-Fired,
or Electric Heaters
It is desirable to pipe the stand-by heater in a bypass
loop. Refer to Figure 10. Fuel-fired heaters often create
Figure 11
DIVIDED
SYSTEM
ASSEMBLY
ON ROOF
9
Figure 12
temperature readings. If they are not identical, make a
notation of the difference and add or subtract (as appropriate) this difference to or from the reading taken while
you are testing. This is necessary in order to provide an
accurate indication of the temperature rise of the water
passing through the solar collectors.
Manual Control of System
To test collector operation, follow either the flow-rate or
temperature-rise procedure. Divert water through the collectors. Turn on the pump and either observe flow rate or
temperature rise. The flow rate or temperature rise would
be the same as that specified in the “System Start-Up and
Test” section. If it is not, then check for the indicated probable causes and make necessary corrections.
Turn the pump on and move the flow switch to the “COLL”
position. Observe valve action...it should divert water
through the collectors. After flow through the collectors has
continued for a least fifteen minutes, compare the pool
water temperature with the temperature of the water flowing through the outlet line. On an average sunny day, with
the air temperature approximately 700F (210C) the water
leaving the collectors should be 1 to 70F (1 to 40C) higher
than that in the pool. If the water rise is greater than this,
insufficient water is flowing through the collectors. This may
be caused by a clogged filter, undersized piping, to many
elbows in the piping or an inadequate pump. It is important that the temperature rise through the collectors be
kept as low as possible in order to deliver the maximum amount of heat to the pool.
FLOW RATE TEST METHODS
Flowmeter
The preferred system test method is flow rate. This is also
the easiest and quickest method. To check flow rate, install
a flow meter in the inlet line to the collectors (follow installation instructions provided with the flowmeter).
Temperature Rise Test Method
An alternate test method is temperature rise. To prepare
the system for testing, obtain two accurate thermometers.
Aquatherm Industries dial thermometers (Part #60054-2)
are excellent for this application. One of these thermometers is installed in the outlet line from the collectors as
shown in Figure 10. The other is used to check the temperature of the pool water, to compare it with that of the
water leaving the solar collectors. Before installing the
thermometer in the outlet line, immerse both thermometers in the pool water for several minutes to compare the
Vacuum Relief Valve Test
When the solar system is first turned on, air in the collectors will be expelled into the pool and bubbles will appear.
The appearance of bubbles in the pool should stop after
a few minutes. If, after a few minutes, bubbles continue to
be discharged at the return to the pool, remove the vacuum
10
relief valve(s) and replace it with and end cap. Relocate a
vacuum relief valve to a position in the inlet piping which
is at a height of approximately three-fourths of the elevation of the collectors above the pool. Refer to Figure 2.
Annual Service
Collector Clamps:
In particularly hot climates, such as Arizona and
Southern Florida, the clamps which are used to connect
the solar collectors may become loose. If you notice
leaks around the hose couplings, use a nutdriver to tighten clamps. Do not tighten to the extent that the pipe collapses or the clamp gears strip. In areas where unusually high stagnation temperatures are prevalent or where
abnormally high system pressures occur, use header
insert (Part #50055-1/-2).
(A quicker alternate method is to first try to reverse the
end cap and the vacuum relief valve on the collector
array to see if this stops the bubbles in the return lines.
Sometimes the end cap is about 3/4 of the elevation of
the collectors and this is a lot quicker than cutting in a tee
in the supply pipe.)
MAINTENANCE
Winterizing Procedures
COLLECTOR REPAIR
This method allows for an easy and permanent on site
repair of a collector by isolating the leaking riser tube.
Referring to the figure below, locate the tube to be isolated. (End tube has been shown for clarity.) Using a sharp
utility knife, very carefully cut away approximately 1” of
the tube at both headers. Drive a #10 - #12 sheet metal
screw, preferably stainless, into the hole in the header.
The screw must be between 1/2” and 3/4” long. DO NOT
OVERTIGHTEN! If the screw strips out, or if the repair
leaks, use a larger screw. This repair method will not void
the collector warranty.
The solar collectors should drain automatically each time
the pump cycles off. There are no special requirements
for winterizing the solar collectors. The pool piping should
be winterized as per your normal practice. In southern
parts of the country pool owners operate their pools
throughout the winter although light freezing conditions
may occur. The accepted procedure for avoiding freezing
of the pool piping and filtration system has been to continuously circulate the water. When solar heaters are
used on a pool under these conditions, anti-freeze precautions should be taken. In order to protect the collectors as well as appurtenant components such as
end caps and pipe fittings and against unusual or
severe freezing conditions, one of the following two
procedures should be followed when freezing weather
is imminent.
1. Turn circulating system off and allow solar collectors
and piping to drain. Isolate collectors with gate or ball
valve in collector feed line and a check valve in the collector return line. Switch the solar control to the bypass
position. The pool filtering system may then be turned
back on. When freezing conditions have passed, open
isolation valves and switch the solar control to “AUTO”.
2. Switch the solar control to the “COLL” position so that
water circulates through the collector. When freezing conditions have passed, switch the solar control to “AUTO”.
THIS METHOD IS NOT RECOMMENDED WHERE
TEMPERATURE LEVELS MAY DROP SEVERELY.
11
VACUUM RELIEF VALVE
SOLAR
COLLECTORS
SOLAR
SENSOR
Figure 14
END
CAP
BOOSTER PUMP
SYSTEM DIAGRAM
FOR OUTDOOR
POOLS
VACUUM
RELIEF VALVE
FLOW
METER
(optional location)
(optional)
OUTLET LINE
THERMOMETER
ELECTRONIC
CONTROL
(optional)
ISOLATION
BALL VALVE
(optional)
VALVE CONTROL LINE
BOOSTER
PUMP
ISOLATION
CHECK VALVE
(optional)
HEATER BY-PASS
BALL VALVE
120/240
V-LINE
(optional)
FILTER
WATER
SENSOR
CHECK
VALVE
3-WAY
VALVE
OUTLET
TEE
HEATER
optional)
PUMP
HEATED OUTLET
FROM COLLECTORS
COLD INLET
FROM POOL
®