Chapter 2 Conducted Emission Test

Transcription

Chapter 2 Conducted Emission Test
Test Report ------------------------------------------------------------------------------- 2/30
Contents
Chapter 0 Emission and Susceptibility Standards.......................................... 3
Chapter 1 Introduction
Description of EUT ................................................................................................................... 4
Configuration of Test Setup ...................................................................................................... 5
List of Support Equipment ........................................................................................................ 6
Chapter 2 Conducted Emission Test
Test Condition and Setup .......................................................................................................... 7
Conducted Test Placement ........................................................................................................ 8
Chapter 3 Radiated Emission Test
Test Condition and Setup .......................................................................................................... 9
Radiated Test Placement .......................................................................................................... 10
Chapter 4 Electrostatic Discharges Immunity Test....................................... 11
EN 61000-4-2 Photo of Test Set-Up ........................................................................................ 12
Chapter 5 Radio Frequency Immunity Test (RS test)................................... 13
EN 61000-4-3 Photo of Test Set-Up ........................................................................................ 14
Chapter 6 Electrical Fast Transient/Burst Test (EFT test)........................... 15
EN 61000-4-4 Photo of Test Set-Up ........................................................................................ 16
Chapter 7 Surge Immunity Test .................................................................................. 17
EN 61000-4-5 Photo of Test Set-Up ........................................................................................ 18
Chapter 8 Continuous Wave Voltage Immunity Test .......................................... 19
EN 61000-4-6 Photo of Test Set-Up ........................................................................................ 20
Chapter 9 Power Frequency Magnetic Field Immunity Test ............................ 21
EN 61000-4-8 Photo of Test Set-Up ........................................................................................ 22
Chapter 10 Voltage DIP / Interruption Immunity Test ...................................... 23
EN 61000-4-11 Photo of Test Set-Up ...................................................................................... 24
Chapter 11 Harmonics Test........................................................................................... 25
Chapter 12 Voltage Fluctuation and Flicker Test ................................................. 26
Appendix A :
Conducted test result ................................................................................................................ 27
Appendix B :
Radiated test result ................................................................................................................... 29
Appendix C :
Photographs of EUT................................................................................................................. 30
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 3/30
Chapter 0
Emission and Susceptibility Standards
Emission Standards
Emission Standard
European Standard
International Standard
(X)
EN 61000-6-3/2001
IEC 61000-6-1/1996
(
)
EN 61000-6-4/2001
IEC 61000-6-1/1997
(
)
EN 50081-1/1992
(
)
EN 50081-1/8.93
(X)
EN 50091-2/1995
(
)
EN 55014/4.93
CISPR 14: 1993
(
)
EN 55015/12.93
CISPR 15: 1992
(
)
EN 55013/2001
CISPR 13: 2001
(
)
EN 55022/98
CISPR 22: 1997
(
)
EN 61000-3-2/2000
IEC 61000-3-2: 2000 + A1: 2001
(
)
EN 61000-3-3/1995+A1: 2001
IEC 61000-3-3: 1994 + A1: 2001
Susceptibility Standards
Susceptibility Standard European Standard
International Standard
(X)
EN 61000-6-1/2001
IEC 61000-6-1/1997
(
)
EN 61000-6-2/2001
IEC 61000-6-1/1999
(
)
EN 50082-1/1997
(
)
EN 50082-2/1994
(X)
EN 55024/1998
CISPR 24/1997
(
EN 55020/2002
CISPR 20/2002
)
(X)
EN 50091-2/1995
(X)
EN 61000-4-2:1995
IEC 61000-4-2:1995
(X)
EN 61000-4-3:1996
IEC 61000-4-3:1995
(X)
EN 61000-4-4:1995
IEC 61000-4-4:1995
(X)
EN 61000-4-5:1995
IEC 61000-4-5:1995
(X)
EN 61000-4-6:1996
IEC 61000-4-6:1996
(X)
EN 61000-4-8:1993
IEC 61000-4-8:1993
(X)
EN 61000-4-11:1994
IEC 61000-4-11:1994
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 4/30
Chapter 1 Introduction
Issued statement:
The EUT is UPS.
There are two samples only with different rating and the PCB layout are all the same.
These devices have been verified over each test item.
Description of EUT:
The EUT is an UPS, features as below:
Model No. Input Rating
Output Rating
M2000E
220-240Vac, 50/60Hz, 12A 2KVA 220-240Vac, 50/60Hz, 10/9/8.7/8.4 A, 2KVA cosψ0.7
M3000E
220-240Vac, 50/60Hz, 18A 3KVA 220-240Vac, 50/60Hz, 15/13.6/13/12.5 A, 3KVA cosψ0.7
Test method:
Pretest was found that the emission of “With Load” mode is worse than “Without Load”
mode. So, The final test is made at the “With Load” mode.
During testing, these model of EUT were powered to dummy load, the following modes
were tested:
#1 Charging at 50% power consumption.
#2 Charging at 100% power consumption.
#3 Discharging at 50% power consumption.
#4 Discharging at 100% power consumption.
The Conduction test was found out that the testing mode: “#2, M3000E” was the worst
case.
The Radiation pretest was found out that the testing mode: “#2, M3000E” was the worst
case.
We only recorded the worst case in this report.
The test placement as the photographs showed is the worst case emission placed. (If the
emission is close to the ambient, the resolution BW and view resolution will be reduced and the
data will be recorded by detection of maximum hold peak mode.)
The testing configuration of test setup is showing in the next page.
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 5/30
Configuration of test setup
Power
Source
Monitor
PC
Loads
Printer
Keyboard
Mouse
USB
USB
Mouse Joystick
Connections:
PC :
*Power port --- via a 1.8 m length power cable to the Power Output port 1 of EUT.
*Serial Port --- via a 1.78 m length RS-232 cable to the serial port of EUT.
*Monitor Port --- a monitor with 1.5m length data cable.
*Keyboard Port --- a keyboard with 1.60m length data cable.
*Mouse Port --- a mouse with 1.8m length data cable.
*USB port A --- a USB joystick with 1.8m long of data cable.
*USB port B--- a USB mouse with 1.8m long of data cable.
*Printer port --- a printer with 1.80m length data cable.
(Each port on PC is connected with suitable device)
EUT:
*Power Input port --- via a 1.8 m length power cable to the power Source.
*Power Output port --- via a 1.8 m length power cable to the power port of the Loads.
*Serial port --- via a 1.78 m length data cable to the RS-232 port of PC.
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 6/30
List of support equipment
PC
Model No.
Serial No.
FCC ID
Power type
Power cord
:
:
:
:
:
:
HP Pavilion t123d
Doc Approved
AC 100 –127 4.0A, 200-240 2.0A, 50 ~ 60Hz
Non-shielded, 2.33m long, Plastic, No ferrite core
Monitor
Model No.
Serial No.
FCC ID
Power type
Power cord
Data cable
:
:
:
:
:
:
:
HP pavilion mx70
P1283A
THTBR00257
DOC Approved
100 ~ 240V AC 15A 50/60Hz
Shielded, 1.83m long, No ferrite core
Shielded, 1.46m (1.80m) long, with two ferrite cores (no ferrite core)
Keyboard
Model No.
Serial No.
FCC ID
Power type
Data cable
:
:
:
:
:
:
HP
5308
BM05301256 REV:2.1
DOC Approved
By PC
Shielded, 1.73m long, with ferrite core
Mouse
Model No.
Serial No.
FCC ID
Power type
Power cord
:
:
:
:
:
:
HP
MO42KOA
0306044011
DOC Approved
By PC
Non-shielded, 1.88m long, No ferrite core
USB Mouse :
Model No.
:
Serial No.
:
FCC ID
:
Power type
:
Power cord :
Logitech Wheel Mouse
M-BJ-58
LN20901985
Doc Approved
By PC
Non-shielded, 1.88m long, No ferrite core
DD281A-AB0
TW31720157
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 7/30
Printer
Model No.
Serial No.
FCC ID
Power type
Power cord
Data cable
:
:
:
:
:
:
:
USB Joystick :
Model No.
:
Serial No.
:
FCC ID
:
Power type
:
Power cable :
HP
C2642A
SG69A196GV
B94C2642X
220VAC, 50Hz
Non-shielded, 2m long, no ferrite core
Shielded, 1.84m long, no ferrite core (1.7m)
Rockfire
QF-337uv
10600545
CE Approval
Powered by PC
Shielded, 1.8m long, No ferrite bead data cable
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 8/30
Chapter 2 Conducted Emission Test
Test condition and setup:
All the equipment is placed and setup according to the EN 55022.
The EUT is assembled on a wooden table that is 80 cm high, is placed 40 cm from the
back-wall that is a vertical conducting plane. One LISN is for EUT, the other LISN is for support
equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch
box for selecting L1 or L2, then connect to a preamplifier and spectrum for pretest.
The spectrum measured from 150KHz to 30MHz. Conducted emission levels are detected
at max. peak mode. But if the max. peak mode failed or over average limit, it will be measured
by QP and average detection mode using the Receiver.
While testing, there is the worst-emission plot printed at peak detection mode, and there are
more than 6 highest emissions relative to limit recorded. The plot is kept as the original data, not
included in test report.
List of test Instrument :
Calibration Date
Instrument Name Model No.
Spectrum analyzer 8591EM
LISN (EUT)
3825/2
LISN (Support E.) 3825/2
Preamplifier
CB-001
Line switch box
CB-01
FTB-1-6 Attenuator
15542
05/28/05
20dB Attenuator CAT-20
BNC3200B-0058
Coixal Cable
Coixal Cable
BNC31VB-0316
50ohm terminator 370BNM
50ohm terminator 370BNM
50ohm terminator 370BNM
50ohm terminator 370BNM
Brand
HP
EMCO
EMCO
TRC
TRC
mini-circuits
Serial No.
3710A01203
9411-2284
9210-2007
98-02
98-04
9620 03
mini-circuits
Jyebao
Jyebao
NARDA
NARDA
NARDA
NARDA
9620 13
CL-05
Last time
05/13/04
07/21/03
09/03/03
05/29/04
05/29/04
05/29/04
05/29/04
05/29/04
IF-01ca0069-036 05/29/04
PWR5W
07/21/03
PWR5W
07/21/03
PWR5W
09/03/03
PWR5W
09/03/03
Next time
05/12/05
07/20/04
09/02/04
05/28/05
05/28/05
05/28/05
05/28/05
05/28/05
07/20/04
07/20/04
09/02/04
09/02/04
The level of confidence of 95% , the uncertainty of measurement of conducted emission is +3.1/-4.84 dB .
Test Result : Pass (Appendix A)
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 9/30
Conducted Test Placement: (Photographs)
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 10/30
Chapter 3 Radiated emission test
Test condition and setup:
Pretest:
Prior to the final test (OATS test), the EUT is placed in a shielded enclosure,
and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the
EUT.
Final test : Final radiation measurements is made on a 10 – meter, open-field test
site. The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x
1.5 meter. The placement is according to EN 55022.
The M. E. whole range Antenna is used to measure frequency from 30 MHz to 1GHz. The
final test is used the Receiver.
Measure more than six top marked frequencies generated form pretest by computer step by
step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from
1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and
vertical polarization.
Appropriated preamplifier that is made by TRC is used for improving sensitivity and
precaution is taken to avoid overloading. The spectrum analyzer’s 6dB bandwidth is set to 120 K
Hz, and the EUT is measured at quasi-peak mode.
If the emission is close to the frequency band of ambient, the tester will recheck the data
and the corrected data will be written in the test data sheet. If the emission is just within the
ambient, the data from shielded room will be taken as the final data.
List of test Instrument :
Calibration Date
Instrument Name
Receiver
Control Box
Antenna
Open test side
Pre-amplifier
Model No.
SCR3102
TWR95-4
CBL6141A
Brand
SCHAFFNER
TRC
SCHAFFNER
TRC-CB-2
Coixal Cable(20meter) RG-214/U
Coixal Cable(50cm)
Coixal Cable(20cm)
Coixal Cable(55cm)
Coixal Cable(55cm)
TRC
Jyebao
BNC31VB-0316 Jyebao
BNC31VB-0318 Jyebao
BNC31VB-0316 Jyebao
BNC31VB-0316 Jyebao
Serial No.
Last time
Next time
012
05/13/04
05/12/05
C9001-2
N/A
N/A
4206
05/27/04
05/26/05
05/29/04
05/28/05
CB-002
05/29/04
05/28/05
CL-002
05/29/04
05/28/05
CL-002
05/29/04
05/28/05
CL-007
05/29/04
05/28/05
CL-006
05/29/04
05/28/05
CL-005
05/29/04
05/28/05
The level of confidence of 95%, the uncertainty of measurement of radiated emission is +2.85/-2.77 dB.
Test Result : Pass (Appendix B)
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 11/30
Radiated Test Placement: (Photographs)
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 12/30
Chapter 4 Radio Frequency Immunity Test (RS)
Test information:
Test setup: According to EN 61000-4-3
Test Frequency:
( X ) 80 ~ 1000 MHz
( ) 27 ~ 500 MHz Without Modulation
Modulation:
( ) FM %
( X ) 80% AM Modulation with 1KHz
( ) 900 KHz ± 5 KHz with PM 200 Hz and 100% depth
Step size:
( X ) ≤ 1% step size
Sweep time:
( X ) 2.5 Second
Field strength:
( ) 1V/m
( X ) 3V/m
( ) 10V/m
Test mode: Ref. Test method of Chapter 1
Test instruments:
Name
Model Number
Serial Number
Selected
Shielding Room
AC5-001
N/A
X
DC Power Supply
GPR-3520H
7090069
X
Signal Generator
900
287104
X
Amplifier
AC5-002
N/A
X
Power Meter
1219-D-007
157
X
Spectrum Analyzer
8594EM
3710A00198
X
Preamplifier
AC3-002
N/A
X
Comment:
Performance Criteria
(X)A
(
)B
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 13/30
EN 61000-4-3 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 14/30
Chapter 5 Electrostatic Discharges Immunity Test
Test information:
Test setup: Shielded Room
Test Voltage:
( X ) 4KV contact discharge
( X ) 8KV air discharge
Indirect Discharges:( X ) HCP
( X ) VCP
Polarity:
( X ) positive ( X ) negative
Test mode: Ref. Test method of Chapter 1
Test points: Each Port of EUT
Test instruments:
Name
Serial Number
Selected
NoiseKen Electrostatic ESS-100L(A)
Discharge Simulator
2100C03605
X
NoiseKen Electrostatic TC-815P
Discharge Gun
2100C03566
X
Comment:
Performance Criteria
Model Number
(
)A
(X)B
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 15/30
EN 61000-4-2 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 16/30
Chapter 6 Electric Fast Transient/Burst Requirements Test
Test information:
Test setup:
According to EN 61000-4-4
Test Voltage: DC Power line
( ) 0.5 KV, 5 KH
AC Power line
(X) 1 KV, 5 KHz
Signal & Control line ( ) 0.5 KV, 5 KHz
( ) 1 KV, 5 KHz
Polarity:
(X) Positive
(X) Negative
Test Duration:
( ) 1 minute
(X ) 3 minutes
Connected lines: ( ) Power line shielded
( X ) Power line non-shielded
( ) Signal & Control line non-shielded
( ) Signal & Control line shielded
Test mode: Ref. Test method of Chapter 1.
Test instruments:
Name
Model Number
BEST EMC Test
Instrument
BEST EMC V2.3 199918-006SC
(-8, -9)
X
Induction Coil
INA 701 BEST
X
Comment:
Performance Criteria
(
)A
(X)B
Serial Number
199922-001SC
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Selected
Test Report ------------------------------------------------------------------------------- 17/30
EN 61000-4-4 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 18/30
Chapter 7 Surge Immunity Test
Test information:
Test setup: According to EN 61000-4-5
Test Voltage: DC Power line ( ) 0.5 KV
AC Power line ( X ) 1 KV, line to line
( X ) 2 KV, line to ground
Control line
( ) 0.5 KV
Signal
( ) 2 KV
Time :
( X ) 1.2/50µs (8/20µs)
Connected lines:
( ) Power line shielded ( X ) Power line non-shielded
( ) Signal & Control line non-shielded ( ) Signal & Control line shielded
Test mode: Ref. Test method of Chapter 1.
Test instrument:
Name
Model Number
Serial Number
BEST EMC Test
Instrument
BEST EMC V2.3 199918-006SC
(-8, -9)
X
Induction Coil
INA 701 BEST
X
199922-001SC
KeyTek
Pulsed-EMI E103,
E501B, 0008260 ~0008264,
Test System
E502B,
E503, 0008254
E505A, E4552A
Comment:
Performance Criteria:
(
)A
(X)B
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Selected
Test Report ------------------------------------------------------------------------------- 19/30
EN 61000-4-5 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 20/30
Chapter 8 Continuous Wave Voltage Immunity Test
Test information:
Test setup: According to EN 61000-4-6
Test Frequency:
( X ) 0.15 ~ 80MHz
Modulation:
( ) FM %
( X ) 80% AM Modulation with 1KHz
( ) 900 MHz ± 5 MHz with PM 200 Hz and 50% duty cycle
Step size:
Field strength:
( X ) ≤ 1% step size
( ) 1V
( X ) 3V
(
) 10V
Test mode: Ref. Test method of Chapter 1
Test instruments:
Name
Model Number Serial Number
Selected
SCHAFFNER
NSG 2070-1
RF-SYNTHE SIZERIAMP2IFIER
1020
X
SCHAFFNER CDN
M325
13773
X
SCHAFFNER CDN
M216
15604
SCHAFFNER CDN
T004
15230
SCHAFFNER CDN
S501
15167
SCHAFFNER FM-Koppelzange
KEMZ 801
14301
Comment:
Performance Criteria:
(X)A
(
)B
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
X
Test Report ------------------------------------------------------------------------------- 21/30
EN 61000-4-6 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 22/30
Chapter 9 Power Frequency Magnetic Field Immunity Test
Test information:
Test setup: According to EN 61000-4-8
Test method : ( X ) Continuous ( ) Short duration
Magnetic Field Strength: ( X ) 1A/m
Frequency: 50Hz
polarization: ( X ) X polarization ( X ) Y polarization ( X ) Z polarization
Test mode: Ref. Test method of Chapter 1
Test Duration:
( X ) 30 seconds ( ) 1~3 seconds
Connected lines: ( ) Power line shielded
( X ) Power line non-shielded
( X ) Signal & Control line non-shielded
( ) Signal & Control line
shielded
** Power Frequency Magnetic Field in the horizontal and vertical polarity.**
Test instruments:
Name
Model Number
Serial Number
Selected
BEST EMC Test
Instrument
BEST EMC V2.3
(-8, -9)
199918-006SC
X
Induction Coil
INA 701 BEST
199922-001SC
X
Comment:
Performance Criteria:
(X)A
(
)B
(
)C
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 23/30
EN 61000-4-8 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 24/30
Chapter
11 Voltage DIP / Interruption Test
Test information:
Test setup: According to EN 61000-4-11
Voltage dips / Test specification / Units:
( X ) > 95%, 0.5period
( X ) 30%, 25periods
Voltage interruptions/ Test specification / Units: ( X ) > 95%, 250periods
Test mode: Ref. Test method of Chapter 1
Test instruments:
Name
Model Number
Serial Number
Selected
BEST EMC Test
Instrument
BEST EMC V2.3 199918-006SC
(-8, -9)
X
Induction Coil
INA 701 BEST
X
199922-001SC
Comment:
Performance Criteria:
Dips: (1) >95%
(
)A
(X)B
(
Interruptions : (2) >95%
(
)A
(
)B
(X)C
(
)A
(
)B
(X)C
Dips : (3) 30%
Test Result : Pass
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
)C
Test Report ------------------------------------------------------------------------------- 25/30
EN 61000-4-11 PHOTO OF TEST SET-UP
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 26/30
Chapter 12
Harmonics Test
Test information:
Test setup: According to EN 61000-3-2
Test Item: Quasi – stationary & Fluctuating Current Harmonics Test
Test mode: Ref. Test method of Chapter 1
Test instrument:
Name
Model Number
Harmonic/Flicker Test HP 6842A
System
Serial Number
Selected
3531A-00102
X
Test Equipment Settings:
Quasi-stationary Current
Harmonics Test
Fluctuating Current
Harmonics Test
Line Voltage
230VAC
230VAC
Line Frequency
50Hz
50Hz
Device Class
A
A
Test Limit Overrides
None
None
Total Number of Failures:
None
None
Total Number of Errors:
None
None
Test Result : N/A
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 27/30
Chapter 13
Voltage Fluctuation and Flicker Test
Test information:
Test setup: According to EN 61000-3-3
Test mode: Ref. Test method of Chapter 1
Test instrument:
Name
Model Number
Harmonic/Flicker Test HP 6842A
System
Serial Number
Selected
3531A-00102
X
Test Equipment Settings:
Line Voltage
230VAC
Line Frequency
50Hz
Test Limit Overrides
None
Total Number of Failures:
Pst: (0), Plt: (0)
Dc: (0), Dmax (0), Dt (0)
Total Number of Errors:
None
Test Result : N/A
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 28/30
Appendix A
Conducted Emission Test Result: (Test Mode: #2, M3000E)
Testing room :
Temperature : 20 ° C
Humidity : 80 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
357.00
65.83
64.60
57.82
79.00
66.00
-8.18
386.00
416.00
66.32
67.52
65.41
67.10
58.00
58.70
79.00
79.00
66.00
66.00
-8.00
-7.30
418.00
68.13
66.99
58.72
79.00
66.00
-7.28
445.00
476.00
505.00
68.96
68.59
66.05
65.63
65.18
64.70
56.31
55.43
54.30
79.00
79.00
73.00
66.00
66.00
60.00
-9.69
-10.57
-5.70
7609.00
23962.00
24015.00
63.42
64.88
64.53
59.15
58.80
59.12
51.71
49.63
49.66
73.00
73.00
73.00
60.00
60.00
60.00
-8.29
-10.37
-10.34
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
7772.00
67.10
63.18
55.16
73.00
60.00
-4.84
23914.00
24030.00
24184.00
70.39
69.41
70.05
63.60
63.58
53.85
53.95
73.00
73.00
60.00
60.00
63.24
53.76
73.00
60.00
-6.15
-6.05
-6.24
24216.00
24418.00
24571.00
24556.00
68.90
70.52
71.24
69.42
62.84
62.82
62.92
53.48
53.29
53.25
73.00
73.00
73.00
60.00
60.00
60.00
63.01
53.25
73.00
60.00
24626.00
69.56
25161.00
25169.00
69.31
67.26
62.70
61.93
61.84
53.12
52.41
52.52
73.00
73.00
73.00
60.00
60.00
60.00
*The reading amplitudes are all under limit.
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
-6.52
-6.71
-6.75
-6.75
-6.88
-7.59
-7.48
Test Report ------------------------------------------------------------------------------- 29/30
Appendix B
Radiated Emission Test Result: (Test Mode: #2, M3000E)
Test Conditions:
Testing site
Frequency
MHz
:
Temperature :
Reading
Ant.
Amplitude
Height
dBµV/m
m
25° C
Table
degree
Humidity : 86 % RH
Correction
Corrected
Class A
Factors
Amplitude
Limit
dB
dBµV/m
dBµV/m
Margin
dB
(Horizontal)
35.9350
32.28
3.97
17
2.11
34.39
40.00
-5.61
37.0440
34.40
3.97
105
1.29
35.69
40.00
-4.31
42.3660
37.34
0.97
145
-1.66
35.68
40.00
-4.32
44.9570
37.56
0.97
326
-2.49
35.07
40.00
-4.93
45.0600
37.18
0.97
107
-2.53
34.65
40.00
-5.35
47.8940
38.54
0.97
228
-3.77
34.77
40.00
-5.23
32.9840
31.85
2.50
171
3.65
35.50
40.00
-4.50
36.4340
32.51
2.50
235
1.74
34.25
40.00
-5.75
38.6050
34.90
2.50
227
0.13
35.03
40.00
-4.97
45.8090
37.08
2.50
296
-2.86
34.22
40.00
-5.78
48.1450
37.94
2.50
316
-3.88
34.06
40.00
-5.94
74.7840
46.01
2.50
77
-10.21
35.80
40.00
-4.20
***
(Vertical)
***
Note:
1. Margin = Amplitude - limit, if margin is minus means under limit.
2. Corrected Amplitude = Reading Amplitude + Correction Factors
3. Correction factor = Antenna factor + ( Cable Loss - Amplitude gain )
(For example : 30MHz correction factor = 15.5 + (-15.26) = 0.24 dB/m)
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report ------------------------------------------------------------------------------- 30/30
Appendix C
Photographs of EUT
Report No.: P44CE449
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778