Product Description
CENTI 2001 Wet Set adhesive is solvent-free,
non-flammable, freeze/thaw stable, and
odorless when dry. CENTI 2001 Wet Set can be
used where other adhesives might present
potential health risks. It is suitable for office
buildings, hotels, hospitals, schools,
restaurants, assisted living facilities, etc.
CENTI 2001 Wet Set contains micro-biocides to
inhibit the growth of mold and mildew. CENTI
2001 Wet Set can be used to install luxury vinyl
tile and vinyl plank flooring over porous floors.
CENTI 2001 Wet Set exhibits quick grab,
excellent moisture resistance, and spreads
easily. Only Tandus Centiva LVT adhesive is to
be used for installing Tandus Centiva LVT.
CENTI 2001 Wet Set may be used to install
Event, Contour,Victory & Venue Series products.
CENTI 2001 Wet Set is manufactured in the
USA for Tandus Centiva US LLC
Product Specifications
Base:
Latex
Color:
Cream
Weight:
9.3 lbs/gal
VOCs:
-0- calculated*
Consistency:
Medium Paste
Shelf Life:
One year, unopened
Open Time:
approximately 25
minutes, depending on
temperature/humidity
and sub-floor porosity
Coverage:
125 sq. ft./gal.
Coverage will vary
depending on floor type
* All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168
standards. For specific LEED® documents concerning Tandus
Centiva LVT adhesives, see tandus-centiva.com
1. Do not use CENTI 2001 Wet Set over
existing resilient flooring or painted subfloors. Not for use over non-porous floors
such as sealed concrete, metal, existing
sheet flooring. It is the responsibility of the
user to determine whether or not the subfloor to be covered is porous. To determine
if a sub-floor is porous, place two droplets of
water in various areas. If the sub-floor is
porous, the water will be absorbed within a
few seconds.
6
3. Make sure all sub-floors are clean, dry, free
of dirt, dust, old adhesives, grease, wax, and
other foreign matter that might interfere
with the adhesive bond. Painted or
varnished surfaces must be sanded and
dust-free. Concrete floors must be fully
cured, free from dust, moisture, excessive
alkalinity, curing agents, and excessive
moisture vapor emissions. If applying over
old cutback, all old adhesive must be
removed so that the floor is smooth.
4. Use a high-quality latex/Portland cement
based-type patching compound to fill or
level any irregular areas.
5. The sub-floor, flooring material, and
adhesive must be acclimatized to the
installation area for a minimum of 48 hours
prior to installation. The area should be fully
enclosed, weather-tight, with permanent
HVAC system set and maintained at a
minimum temperature of 68-72°F for 48
hours prior to, during, and after installation.
6. It is essential that moisture tests be
performed on all concrete sub-floors
regardless of grade level or whether or not
the concrete is freshly poured or is classified
as an older slab. Moisture testing should be
performed using ASTM F 1869 (calcium
chloride test) or ASTM F 2170 (relative
humidity). Moisture levels should not
exceed 6 lbs/1,000 sq. ft. (CC) or 75%
relative humidity in a 24 hour time period. If
test results exceed the limitations, the
installation should not proceed until the
problem is corrected. See ASTM F 710 for
additional information.
9. Check open time periodically by lifting a
section just laid to be certain that at least
95% of the adhesive pattern has been
transferred to the back of the plank or tile.
10. Position planks or tile firmly in the adhesive
without sliding them.
11. Roll each section immediately upon
completion with a 100 lb sectional roller. Reroll the entire floor after 1-2 hours.
12. Remove wet adhesive immediately with a
damp cloth. Use mineral spirits to remove
dried adhesive. Do not apply solvents
directly to flooring material as a loss of
strength/gloss/texture may result. If a tile
needs to be cleaned of excess adhesive
material on the finished surface, use the
solvent sparingly in a slight rubbing manner.
Limitations
13. Store indoors only. Protect from freezing.
Adhesive is freeze/thaw stable to 10°F.
Prolonged or repeated freeze/thaw cycles
should be avoided. Should adhesive freeze,
allow to thaw at room temperature and stir
well before using. The finished installation
must be protected from moisture and/or
freezing for a minimum of 48 hours.
14. Restrict heavy foot traffic or rolling loads for
at least 24 hours.
15. Do not wash or wax the floor for a minimum
of 48 hours after installation.
16. Not for use over non-porous floors.
Apply Adhesive
Prepare Surface
TANDUS-CENTIVA.COM
2. Use CENTI 2001 Wet Set on grade, above
grade, or below grade. CENTI 2001 Wet Set
may be used over porous structurally- sound
surfaces of plywood and concrete.
7. Apply adhesive using a 1⁄16 x 1⁄16 x 1⁄16 inch
square notched trowel.
8. Apply only that amount of adhesive that can
be covered in 25 minutes. Open time will
vary according to temperature, humidity,
and porosity of the sub-floor. For best
results, let the adhesive flash off before
installing the planks or tile. Do not allow
adhesive to skin over. If the open time is
exceeded and the film has skinned over,
adhesive must be scraped up, then
reapplied.
1701 Mars Hill Road, Florence AL USA 35630
1.888.CENTIVA
Use a 1⁄16 x 1⁄16 x 1⁄16 inch
square notched trowel.
Tel: 256.767.4990
Fax: 256.760.1763
CENTI 6000 SP Special Purpose Adhesive
Resilient Floor Tile and Plank Adhesive Specification
Product Description
CENTI 6000 SP Special Purpose adhesive is
solvent-free, non-flammable, freeze/thaw
stable, and odorless when dry. CENTI 6000 SP
can be used where other adhesives might
present potential health risks. It is suitable for
office buildings, hotels, hospitals, schools,
restaurants, assisted living facilities, etc. CENTI
6000 SP contains micro-biocides to inhibit the
growth of mold and mildew. CENTI 6000 SP can
be used to install luxury vinyl tile and vinyl plank
flooring over porous and non-porous floors.
CENTI 6000 SP exhibits quick grab, excellent
moisture resistance, and spreads easily. Centi
6000 SP has excellent resistance to plasticizer
migration and sets to a tough permanent bond.
Only Tandus Centiva adhesive is to be used for
installing Tandus Centiva LVT.
CENTI 6000 SP may be used to install Event,
Contour, Victory & Venue Series products,
excluding Coral Reef, Magics, and Mineral Chip.
CENTI 6000 SP is manufactured in the USA for
Tandus Centiva US LLC
Product Specifications
Base:
Acrylic
Color:
White
Weight:
9.7 lbs/gal
VOCs:
-0- calculated*
Consistency:
Medium Paste
Shelf Life:
1 year at 70˚F, unopened
Open Time:
on
45 minutes, depending
temperature/humidity
and sub-floor porosity
Coverage:
120-130 sq. ft./gal.
Coverage will vary
depending on floor type
* All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168
standards. For specific LEED® documents concerning Tandus
Centiva LVT adhesives, see tandus-centiva.com
Prepare Surface
1. CENTI 6000 SP may be used on all grade
levels of concrete-on, above, or below
grade, in the absence of moisture, as well as
suspended approved wood floors (APA).
2. Make sure all sub-floors are clean, dry, free
of dirt, dust, old adhesives, grease, wax, and
other foreign matter that might interfere
with the adhesive bond. Painted or
varnished surfaces must be sanded and
1701 Mars Hill Road, Florence AL USA 35630
dust-free. Concrete floors must be fully
cured, free from dust, moisture, excessive
alkalinity, curing agents, and excessive
moisture vapor emissions.
3. Use a high-quality latex/Portland cement
based-type patching compound to fill or
level any irregular areas.
4. The sub-floor, flooring material, and
adhesive must be acclimatized to the
installation area for a minimum of 48 hours
prior to installation. The area should be fully
enclosed, weather-tight, with permanent
HVAC system set and maintained at a
minimum temperature of 68-72°F for 48
hours prior to, during, and after installation.
5. It is essential that moisture tests be
performed on all concrete sub-floors
regardless of grade level or whether or not
the concrete is freshly poured or is classified
as an older slab. Moisture testing should be
performed using ASTM F 1869 (calcium
chloride test) or ASTM F 2170 (relative
humidity). Moisture levels should not
exceed 6 lbs/1,000 sq. ft. (CC) or 75%
relative humidity in a 24 hour time period. If
test results exceed the limitations, the
installation should not proceed until the
problem is corrected. See ASTM F 710 for
additional information.
6. CENTI 6000 SP is recommended for porous
and non-porous applications. It is the
responsibility of the user to determine
whether or not the sub-floor to be covered
is porous. To determine if a sub-floor is
porous, place two droplets of water in
various areas. If the sub-floor is porous, the
water will be absorbed within a few
seconds.
been placed into the adhesive with a 100 lb
roller. Remove any excess adhesive when rolling.
9. From the time the adhesive is allowed to dry to
the touch, to the time it must be covered is 3040 minutes depending on temperature and
humidity. If the adhesive is allowed to remain
uncovered, after initially drying, for periods
longer than recommended, a loss in adhesion
strength will result. The installer must take care
not to spread more adhesive than can be
worked appropriately within the recommended
time frame.
10. Remove wet adhesive immediately with a
damp cloth. Use mineral spirits to remove
dried adhesive. Do not apply solvents directly
to flooring material as a loss of
strength/gloss/texture may result. If a tile
needs to be cleaned of excess adhesive
material on the finished surface, use the
solvent sparingly in a slight rubbing manner.
Limitations
11. Store indoors only. Protect from freezing.
Adhesive is freeze/thaw stable 5 cycles to 0°F.
Prolonged or repeated freeze/thaw cycles
should be avoided. Should adhesive freeze,
allow to thaw at room temperature and stir well
before using. The finished installation must be
protected from moisture and/or freezing for a
minimum of 48 hours.
12. Restrict heavy foot traffic and rolling loads for
24 hours.
13. Do not wash or wax the floor for a minimum of
48 hours after installation.
Apply Adhesive
7. For porous sub-floors, apply adhesive using a
1
⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. Once
troweled, the adhesive should be allowed to
remain open (flash off) for 5-10 minutes before
placement of the flooring material. Once
placed, the material should be rolled
immediately using a 100 lb roller. Remove any
excess adhesive when rolling.
8. For non-porous sub-floors, apply adhesive
using a 1⁄32 x 1⁄16 x 1⁄32 inch U-notched trowel.
Adhesive must be allowed to dry to touch, so
that there is little or no transfer of adhesive to
the finger. Once the adhesive dries to the
touch, it is ready to accept flooring material.
Roll immediately after the flooring material has
1.888.CENTIVA
Tel: 256.767.4990
Use a 1⁄16 x 1⁄16 x 1⁄16 inch
square notched trowel.
(porous)
Use a 1⁄32 x 1⁄16 x 1⁄32 inch
U-notched trowel.
(non-porous)
Fax: 256.760.1763
TANDUS-CENTIVA.COM
7
CENTI 2000 EP Epoxy Adhesive Parts A & B
Resilient Floor Tile and Plank Adhesive Specification
Product Description
CENTI 2000 EP Epoxy adhesive is solvent-free,
non-flammable, and odorless when dry. CENTI
2000 EP can be used where other adhesives
might present potential health risks. It is
suitable for office buildings, hotels, hospitals,
schools, restaurants, assisted living facilities,
etc. CENTI 2000 EP contains micro-biocides to
inhibit the growth of mold and mildew. CENTI
2000 EP is a two-component product and cures
to a tough, flexible film. It is recommended for
the installation of vinyl flooring products on
approved sub-floors for both porous and nonporous applications. It is especially recommended
for use on non-porous sub-floors. Only Tandus
Centiva adhesive is to be used for installing
Tandus Centiva LVT.
CENTI 2000 EP may be used to install Event,
Contour, Victory & Venue Series products.
CENTI 2000 EP is manufactured in the USA for
Tandus Centiva US LLC
Product Specifications
Base:
Epoxy
Color:
Beige
Weight:
12.5 lbs/gal
VOCs:
-0- calculated*
Consistency:
Medium Paste
Shelf Life:
1 year at 70˚F, unopened
Open Time:
40-50minutes, depending
on temperature/humidity
and sub-floor porosity
Coverage:
130-150 sq. ft./gal.
Coverage will vary
depending on floor type
standards. For specific LEED® documents concerning Tandus
Centiva LVT adhesives, see tandus-centiva.com
Prepare Surface
1. CENTI 2000 EP may be used on all grade
levels of concrete-on, above, or below
grade, in the absence of moisture, as well as
suspended approved wood floors (APA).
2. Make sure all sub-floors are clean, dry, free of
dirt, dust, old adhesives, grease, wax, and other
foreign matter that might interfere with the
adhesive bond. Painted or varnished surfaces
must be sanded and dust-free. Concrete floors
must be fully cured, free from dust, moisture,
excessive alkalinity, curing agents, and
excessive moisture vapor emissions.
8
4. The sub-floor, flooring material, and
adhesive must be acclimatized to the
installation area for a minimum of 48 hours
prior to installation. The area should be fully
enclosed, weather-tight, with permanent
HVAC system set and maintained at a
minimum temperature of 68-72°F for 48
hours prior to, during, and after installation.
If adhesive is subject to heat, setup time will
be shortened significantly. The opposite will
occur if stored in a cold area.
5. It is essential that moisture tests be
performed on all concrete sub-floors
regardless of grade level or whether or not
the concrete is freshly poured or is classified
as an older slab. Moisture testing should be
performed using ASTM F 1869 (calcium
chloride test) or ASTM F 2170 (relative
humidity). Moisture levels should not
exceed 6 lbs/1,000 sq. ft. (CC) or 75%
relative humidity in a 24 hour time period. If
test results exceed the limitations, the
installation should not proceed until the
problem is corrected. See ASTM F 710 for
additional information.
8. After installation roll the floor using a 100 lb
sectional roller, first in one direction and
then in a direction at a right angle to the first
line of direction. Remove any excess
adhesive when rolling. THE FLOOR MUST
BE ROLLED BEFORE THE ADHESIVE
HARDENS.
9. Use denatured alcohol or mineral spirits to
remove wet adhesive. Do not apply solvents
directly to flooring material as a loss of
strength/gloss/texture may result. If a tile
needs to be cleaned of excess adhesive
material on the finished surface, use the
solvent sparingly in a slight rubbing manner.
Cured adhesive is very difficult to remove.
Limitations
10. Store indoors only. Protect from freezing.
Adhesive is freeze/thaw stable to 0°F.
Prolonged or repeated freeze/thaw cycles
should be avoided. Should adhesive freeze,
allow to thaw at room temperature and stir
well before using. The finished installation
must be protected from moisture and/or
freezing for a minimum of 24 hours.
11. Allow 8-12 hours for light foot traffic and 2448 hours for heavy foot traffic.
12. Do not wash or wax the floor for a minimum
of 48 hours after installation.
Apply Adhesive
* All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168
TANDUS-CENTIVA.COM
3. Use a high-quality latex/Portland cement
based-type patching compound to fill or
level any irregular areas.
6. A unit of CENTI 2000 EP consists of two (2)
parts labeled Part A and Part B. After
opening each container use a can opener to
cut the rims off both containers. Thoroughly
mix Part A and Part B separately. Combine
the two (2) parts making sure that ALL of the
contents of one can are added to ALL the
contents of the second can. Mix the two
parts together thoroughly until they are a
uniform color. Immediately after mixing the
two parts together, pour the contents into
an open, flat pan or on the floor. Epoxy
adhesive cures by chemical reaction; the
heat generated by that process reduces the
open time and curing is accelerated if left in
the can.
Use a 1⁄16 x 1⁄16 x 1⁄16 inch
square notched trowel.
7. Spread the adhesive using a 1⁄16 x 1⁄16 x 1⁄16 inch
square notched trowel. After spreading the
adhesive lay the tile into it immediately. Check
open time periodically by lifting a section just
laid to be certain there is transfer of adhesive
to the back of the floor covering. The open
time will vary with the temperature, humidity,
and porosity of the sub-floor. Use a kneeling
board or work off of the tile whenever possible.
1701 Mars Hill Road, Florence AL USA 35630
1.888.CENTIVA
Tel: 256.767.4990
Fax: 256.760.1763
| S
CHÖNOX Roll and Go™
®
Product data sheet
10.67
Rollable Acrylic Adhesive for Luxury Vinyl Tiles
suitable for bonding of luxury vinyl tiles (LVT) on suitable substrates in interior areas.
Product characteristics
EMICODE EC1: very low emission
for interior use only
solvent free
long open time
high coverage
to be applied with SCHÖNOX Roll and
Go™ ROLLER
upright application
easy to apply
low odor
can take immediate loading
s uitable on underfloor heating systems
s uitable on all SCHÖNOX floor leveling
compounds, preferably SCHÖNOX AP
conforms with MED 96/98/EC
Applications
SCHÖNOX Roll and Go™ is suitable for
bonding of:
Luxury Vinyl in Sheets and Tiles following
the list of approved LVTs (available on
Internet) on SCHÖNOX self leveling
compounds or smooth, porous concrete
in residential and commercial areas.
Requirements of substrate
B efore using SCHÖNOX Roll and Go™
prime the thoroughly dried SCHÖNOX self
leveling compound (preferably SCHÖNOX
AP) or smooth, porous concrete with
SCHÖNOX KH FIX following the referring
product data sheet.
S ubfloors must be smooth, sound, clean,
dry and free of any contaminants which
may hinder adhesion.
S urface treatments or any “friable” areas
of the subfloor must be mechanically
removed and the subfloor repaired with
SCHÖNOX underlayments as required.
To ensure an ideal, dust-free surface,
vacuum the substrate properly using an
industrial vacuum cleaner.
W ith subsequent laying of floor coverings
on
cementitious
substrates,
where
moisture readings are above 85% RH or
6 lbs./1000 sq.ft./24hrs. then application
of SCHÖNOX SDG or SCHÖNOX EPA may be
used to suppress residual moisture (see
data sheet). Always follow the directions
of the floor covering manufacturer
regarding
the
maximum
allowable
moisture content and test the substrate
prior to installing SCHÖNOX Roll and
Go™.
Gypsum screeds should always be dry. Do
not use moisture mitigation systems on
gypsum substrates.
ld water-soluble adhesives should be
O
removed completely, old water-resistant
adhesives
should
be
mechanically
removed as far as possible. The complete
mechanical removal of cutback (i.e.
grinding, sanding, blasting) can be
hazardous as old cutback adhesive
may contain asbestos. Do not sand or
grind adhesive residue. Harmful dust
may result. Inhalation of asbestos
dust may cause asbestosis or other
serious bodily harm. Please consult the
adhesive manufacturer and all applicable
government agencies for rules and
regulations concerning the removal
of flooring and adhesives that contain
asbestos. Prime remaining adhesive
residues accordingly.
F ollow the technical product information
of the LVT manufacturers regarding
specific substrate requirements for their
coverings.
All slabs on or below grade level must
be known to have an intact vapor
retarder directly beneath the concrete in
conformance to the relevant standards.
If in doubt, please contact our SCHÖNOX
representative for further advise.
O ld, suitable and well fitted coverings
should be thoroughly cleaned, sanded,
primed and leveled with SCHÖNOX AP.
T he requirements of the relevant valid
standards, guidelines and data sheets
apply.
Recommended method of
working
S CHÖNOX Roll and Go™ is stirred before
use.
Coverings to be bonded with SCHÖNOX
Roll and Go™ should be conditioned,
unstressed and in a flat position.
Apply SCHÖNOX Roll and Go™ with
the SCHÖNOX Roll and Go™ ROLLER
evenly on the substrate avoiding pools of
adhesive.
After fitting the LVT without any bubbles,
roll the covering using a metal roller. A
second rolling should be done if required
at a later stage.
Trafficking, loading and polishing of
coverings bonded with SCHÖNOX Roll
and Go™ can be done immediately.
T he replacement of planks/tiles is
possible
without
further
substrate
preparation using SCHÖNOX Roll and
Go™. Replacements are done using the
contact method first applying SCHÖNOX
| www.schonox.us |
Technical data
Basis:
acrylic dispersion with bonding
additives
Color: light green
Density: 1.0 kg/l
storage temperature: not below 41 °F
floor temperature: not below 51 °F
coverage:- a pprox. 540 sq.ft. per 1.06
gal. unit (as part of the
SCHÖNOX ROLL AND GOSet)
- a pprox. 2,025 sq.ft. per 3.96
gal. unit
waiting time: approx. 10-15 min
open time: approx. 2 hours
drying time: none, immediately loadable
final strength: after approx. 72 hours
All values are approximate, are subject
to local climatic fluctuations based upon
conditions at 70°F with atmosphere of
less than 65 % relative humidity following
the recommended mixing ratio. Do not
install under­lay­ment or topping before the
substrate has dried thorough­ly.
| SCHÖNOX Roll and Go™
®
Roll and Go™ on the backing of the new
LVT. After drying to transparency press
the covering to the substrate covered
with SCHÖNOX Roll and Go™.
Remove fresh securing spots by using
soapy water, dried spots clean with
SCHÖNOX FIX CLEAN.
Limited suitability in heavy loaded
areas
(humidity,
temperature)
as
conservatories. Contact us for further
advice.
Packaging
kg / 1.06 gallons in plastic container as
4
part of the SCHÖNOX Roll and Go™-SET:
1
1
2
1
1
1
SCHÖNOX Roll and Go™ 4 kg/1.06 gal.
SCHÖNOX Roll and Go™ ROLLER
SCHÖNOX KH FIX 1 kg/0.25 gal.
SCHÖNOX KH FIX ROLLER
SCHÖNOX HANDLE
SCHÖNOX TRAY
15 kg / 3.96 gallons in plastic container
Storage
and follow all cautions and warnings
on product label. For complete safety
information, please refer to the Material
Safety Data Sheet, or visit our website at
www.schonox.us.
Limitation of Liability
To the best of our knowledge, the technical
data contained herein are true and accurate
at the date of issuance but are subject to
change without prior notice. We guarantee
our product to conform to the specifications
contained herein. We make no other
warranty or guarantee of any kind, express
or implied, including merchantability and
fitness for particular purpose. Liability, if any,
is limited to replacement of the product or
refund of the purchase price. Labor or cost
of labor and other consequential damages
are hereby excluded. SCHÖNOX does not
authorize
anyone,
including
SCHÖNOX
Representatives, to make any statements
which supersede, modify or supplement the
information provided on its printed literature
or package labels without written
confirmation.
Product data sheet
10.67
The applicable recommendations, guidelines,
regulations and safety data sheets are to
be obser ved, together with the recognized
architectural and engineering regulations. We
guarantee that our products leave the factor y in
perfect condition. While our recommendations
for
use
are
based
on
tests
and
practical
experience, they can only provide general
guidance without any assurance as to product
characteristics, since we have no influence
over the conditions on site, the execution of
the work or the method of processing. This
product data sheet supersedes all previous
editions.
tore in cool, frost-free conditions.
S
S helf life: 1 year unopened.
Containers that have been opened should
be closed immediately.
Remove any skin that has formed, do not
stir in.
Disposal
mpty containers and dispose of in
E
accordance with federal, state and local
waste disposal regulations.
VOC Content
0g/l (calculated), SCAQMD 1168
LEED
Precautions
ollow the product data sheets for the
F
SCHÖNOX
supplementary
products
mentioned and used.
If in doubt, please obtain further
manufacturer’s information or test in a
small area.
Avoid eye and skin contact. Close
container after each use. Do not reuse
container. Do not flush adhesive down
drains, sewers or waterways. KEEP OUT
OF REACH OF CHILDREN. Carefully read
The SCHÖNOX management system is certified
to ISO 9001 and 14001 by DQS.
SCHÖNOX GmbH
P.O. Box 11 40
D-48720 Rosendahl/Germany
Phone
+49 (0) 2547-910-0
Fax
+49 (0) 2547-910-101
[email protected]
http://www.schoenox.com
In North America provided by:
HPS North America, Inc
Phone:256.246.0345
Fax:256.246.0346
Email:[email protected]
http://www.hpsubfloors.com
| Let´s stick together | www.schonox.us |
B _1067us_13-10
May help contribute to LEED certification of
projects in the categories:
IEQ Credit 4.1
Low-Emitting Materials –
Adhesives & Sealants 1 point
IEQ Credit 4.3
Low-Emitting Materials –
Flooring Systems 1 point