CENTI 2001 Wet Set Adhesive
Transcription
CENTI 2001 Wet Set Adhesive
CENTI 2001 Wet Set Adhesive Resilient Floor Tile and Plank Adhesive Specification Product Description CENTI 2001 Wet Set adhesive is solvent-free, non-flammable, freeze/thaw stable, and odorless when dry. CENTI 2001 Wet Set can be used where other adhesives might present potential health risks. It is suitable for office buildings, hotels, hospitals, schools, restaurants, assisted living facilities, etc. CENTI 2001 Wet Set contains micro-biocides to inhibit the growth of mold and mildew. CENTI 2001 Wet Set can be used to install luxury vinyl tile and vinyl plank flooring over porous floors. CENTI 2001 Wet Set exhibits quick grab, excellent moisture resistance, and spreads easily. Only Tandus Centiva LVT adhesive is to be used for installing Tandus Centiva LVT. CENTI 2001 Wet Set may be used to install Event, Contour,Victory & Venue Series products. CENTI 2001 Wet Set is manufactured in the USA for Tandus Centiva US LLC Product Specifications Base: Latex Color: Cream Weight: 9.3 lbs/gal VOCs: -0- calculated* Consistency: Medium Paste Shelf Life: One year, unopened Open Time: approximately 25 minutes, depending on temperature/humidity and sub-floor porosity Coverage: 125 sq. ft./gal. Coverage will vary depending on floor type * All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168 standards. For specific LEED® documents concerning Tandus Centiva LVT adhesives, see tandus-centiva.com 1. Do not use CENTI 2001 Wet Set over existing resilient flooring or painted subfloors. Not for use over non-porous floors such as sealed concrete, metal, existing sheet flooring. It is the responsibility of the user to determine whether or not the subfloor to be covered is porous. To determine if a sub-floor is porous, place two droplets of water in various areas. If the sub-floor is porous, the water will be absorbed within a few seconds. 6 3. Make sure all sub-floors are clean, dry, free of dirt, dust, old adhesives, grease, wax, and other foreign matter that might interfere with the adhesive bond. Painted or varnished surfaces must be sanded and dust-free. Concrete floors must be fully cured, free from dust, moisture, excessive alkalinity, curing agents, and excessive moisture vapor emissions. If applying over old cutback, all old adhesive must be removed so that the floor is smooth. 4. Use a high-quality latex/Portland cement based-type patching compound to fill or level any irregular areas. 5. The sub-floor, flooring material, and adhesive must be acclimatized to the installation area for a minimum of 48 hours prior to installation. The area should be fully enclosed, weather-tight, with permanent HVAC system set and maintained at a minimum temperature of 68-72°F for 48 hours prior to, during, and after installation. 6. It is essential that moisture tests be performed on all concrete sub-floors regardless of grade level or whether or not the concrete is freshly poured or is classified as an older slab. Moisture testing should be performed using ASTM F 1869 (calcium chloride test) or ASTM F 2170 (relative humidity). Moisture levels should not exceed 6 lbs/1,000 sq. ft. (CC) or 75% relative humidity in a 24 hour time period. If test results exceed the limitations, the installation should not proceed until the problem is corrected. See ASTM F 710 for additional information. 9. Check open time periodically by lifting a section just laid to be certain that at least 95% of the adhesive pattern has been transferred to the back of the plank or tile. 10. Position planks or tile firmly in the adhesive without sliding them. 11. Roll each section immediately upon completion with a 100 lb sectional roller. Reroll the entire floor after 1-2 hours. 12. Remove wet adhesive immediately with a damp cloth. Use mineral spirits to remove dried adhesive. Do not apply solvents directly to flooring material as a loss of strength/gloss/texture may result. If a tile needs to be cleaned of excess adhesive material on the finished surface, use the solvent sparingly in a slight rubbing manner. Limitations 13. Store indoors only. Protect from freezing. Adhesive is freeze/thaw stable to 10°F. Prolonged or repeated freeze/thaw cycles should be avoided. Should adhesive freeze, allow to thaw at room temperature and stir well before using. The finished installation must be protected from moisture and/or freezing for a minimum of 48 hours. 14. Restrict heavy foot traffic or rolling loads for at least 24 hours. 15. Do not wash or wax the floor for a minimum of 48 hours after installation. 16. Not for use over non-porous floors. Apply Adhesive Prepare Surface TANDUS-CENTIVA.COM 2. Use CENTI 2001 Wet Set on grade, above grade, or below grade. CENTI 2001 Wet Set may be used over porous structurally- sound surfaces of plywood and concrete. 7. Apply adhesive using a 1⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. 8. Apply only that amount of adhesive that can be covered in 25 minutes. Open time will vary according to temperature, humidity, and porosity of the sub-floor. For best results, let the adhesive flash off before installing the planks or tile. Do not allow adhesive to skin over. If the open time is exceeded and the film has skinned over, adhesive must be scraped up, then reapplied. 1701 Mars Hill Road, Florence AL USA 35630 1.888.CENTIVA Use a 1⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. Tel: 256.767.4990 Fax: 256.760.1763 CENTI 6000 SP Special Purpose Adhesive Resilient Floor Tile and Plank Adhesive Specification Product Description CENTI 6000 SP Special Purpose adhesive is solvent-free, non-flammable, freeze/thaw stable, and odorless when dry. CENTI 6000 SP can be used where other adhesives might present potential health risks. It is suitable for office buildings, hotels, hospitals, schools, restaurants, assisted living facilities, etc. CENTI 6000 SP contains micro-biocides to inhibit the growth of mold and mildew. CENTI 6000 SP can be used to install luxury vinyl tile and vinyl plank flooring over porous and non-porous floors. CENTI 6000 SP exhibits quick grab, excellent moisture resistance, and spreads easily. Centi 6000 SP has excellent resistance to plasticizer migration and sets to a tough permanent bond. Only Tandus Centiva adhesive is to be used for installing Tandus Centiva LVT. CENTI 6000 SP may be used to install Event, Contour, Victory & Venue Series products, excluding Coral Reef, Magics, and Mineral Chip. CENTI 6000 SP is manufactured in the USA for Tandus Centiva US LLC Product Specifications Base: Acrylic Color: White Weight: 9.7 lbs/gal VOCs: -0- calculated* Consistency: Medium Paste Shelf Life: 1 year at 70˚F, unopened Open Time: on 45 minutes, depending temperature/humidity and sub-floor porosity Coverage: 120-130 sq. ft./gal. Coverage will vary depending on floor type * All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168 standards. For specific LEED® documents concerning Tandus Centiva LVT adhesives, see tandus-centiva.com Prepare Surface 1. CENTI 6000 SP may be used on all grade levels of concrete-on, above, or below grade, in the absence of moisture, as well as suspended approved wood floors (APA). 2. Make sure all sub-floors are clean, dry, free of dirt, dust, old adhesives, grease, wax, and other foreign matter that might interfere with the adhesive bond. Painted or varnished surfaces must be sanded and 1701 Mars Hill Road, Florence AL USA 35630 dust-free. Concrete floors must be fully cured, free from dust, moisture, excessive alkalinity, curing agents, and excessive moisture vapor emissions. 3. Use a high-quality latex/Portland cement based-type patching compound to fill or level any irregular areas. 4. The sub-floor, flooring material, and adhesive must be acclimatized to the installation area for a minimum of 48 hours prior to installation. The area should be fully enclosed, weather-tight, with permanent HVAC system set and maintained at a minimum temperature of 68-72°F for 48 hours prior to, during, and after installation. 5. It is essential that moisture tests be performed on all concrete sub-floors regardless of grade level or whether or not the concrete is freshly poured or is classified as an older slab. Moisture testing should be performed using ASTM F 1869 (calcium chloride test) or ASTM F 2170 (relative humidity). Moisture levels should not exceed 6 lbs/1,000 sq. ft. (CC) or 75% relative humidity in a 24 hour time period. If test results exceed the limitations, the installation should not proceed until the problem is corrected. See ASTM F 710 for additional information. 6. CENTI 6000 SP is recommended for porous and non-porous applications. It is the responsibility of the user to determine whether or not the sub-floor to be covered is porous. To determine if a sub-floor is porous, place two droplets of water in various areas. If the sub-floor is porous, the water will be absorbed within a few seconds. been placed into the adhesive with a 100 lb roller. Remove any excess adhesive when rolling. 9. From the time the adhesive is allowed to dry to the touch, to the time it must be covered is 3040 minutes depending on temperature and humidity. If the adhesive is allowed to remain uncovered, after initially drying, for periods longer than recommended, a loss in adhesion strength will result. The installer must take care not to spread more adhesive than can be worked appropriately within the recommended time frame. 10. Remove wet adhesive immediately with a damp cloth. Use mineral spirits to remove dried adhesive. Do not apply solvents directly to flooring material as a loss of strength/gloss/texture may result. If a tile needs to be cleaned of excess adhesive material on the finished surface, use the solvent sparingly in a slight rubbing manner. Limitations 11. Store indoors only. Protect from freezing. Adhesive is freeze/thaw stable 5 cycles to 0°F. Prolonged or repeated freeze/thaw cycles should be avoided. Should adhesive freeze, allow to thaw at room temperature and stir well before using. The finished installation must be protected from moisture and/or freezing for a minimum of 48 hours. 12. Restrict heavy foot traffic and rolling loads for 24 hours. 13. Do not wash or wax the floor for a minimum of 48 hours after installation. Apply Adhesive 7. For porous sub-floors, apply adhesive using a 1 ⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. Once troweled, the adhesive should be allowed to remain open (flash off) for 5-10 minutes before placement of the flooring material. Once placed, the material should be rolled immediately using a 100 lb roller. Remove any excess adhesive when rolling. 8. For non-porous sub-floors, apply adhesive using a 1⁄32 x 1⁄16 x 1⁄32 inch U-notched trowel. Adhesive must be allowed to dry to touch, so that there is little or no transfer of adhesive to the finger. Once the adhesive dries to the touch, it is ready to accept flooring material. Roll immediately after the flooring material has 1.888.CENTIVA Tel: 256.767.4990 Use a 1⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. (porous) Use a 1⁄32 x 1⁄16 x 1⁄32 inch U-notched trowel. (non-porous) Fax: 256.760.1763 TANDUS-CENTIVA.COM 7 CENTI 2000 EP Epoxy Adhesive Parts A & B Resilient Floor Tile and Plank Adhesive Specification Product Description CENTI 2000 EP Epoxy adhesive is solvent-free, non-flammable, and odorless when dry. CENTI 2000 EP can be used where other adhesives might present potential health risks. It is suitable for office buildings, hotels, hospitals, schools, restaurants, assisted living facilities, etc. CENTI 2000 EP contains micro-biocides to inhibit the growth of mold and mildew. CENTI 2000 EP is a two-component product and cures to a tough, flexible film. It is recommended for the installation of vinyl flooring products on approved sub-floors for both porous and nonporous applications. It is especially recommended for use on non-porous sub-floors. Only Tandus Centiva adhesive is to be used for installing Tandus Centiva LVT. CENTI 2000 EP may be used to install Event, Contour, Victory & Venue Series products. CENTI 2000 EP is manufactured in the USA for Tandus Centiva US LLC Product Specifications Base: Epoxy Color: Beige Weight: 12.5 lbs/gal VOCs: -0- calculated* Consistency: Medium Paste Shelf Life: 1 year at 70˚F, unopened Open Time: 40-50minutes, depending on temperature/humidity and sub-floor porosity Coverage: 130-150 sq. ft./gal. Coverage will vary depending on floor type standards. For specific LEED® documents concerning Tandus Centiva LVT adhesives, see tandus-centiva.com Prepare Surface 1. CENTI 2000 EP may be used on all grade levels of concrete-on, above, or below grade, in the absence of moisture, as well as suspended approved wood floors (APA). 2. Make sure all sub-floors are clean, dry, free of dirt, dust, old adhesives, grease, wax, and other foreign matter that might interfere with the adhesive bond. Painted or varnished surfaces must be sanded and dust-free. Concrete floors must be fully cured, free from dust, moisture, excessive alkalinity, curing agents, and excessive moisture vapor emissions. 8 4. The sub-floor, flooring material, and adhesive must be acclimatized to the installation area for a minimum of 48 hours prior to installation. The area should be fully enclosed, weather-tight, with permanent HVAC system set and maintained at a minimum temperature of 68-72°F for 48 hours prior to, during, and after installation. If adhesive is subject to heat, setup time will be shortened significantly. The opposite will occur if stored in a cold area. 5. It is essential that moisture tests be performed on all concrete sub-floors regardless of grade level or whether or not the concrete is freshly poured or is classified as an older slab. Moisture testing should be performed using ASTM F 1869 (calcium chloride test) or ASTM F 2170 (relative humidity). Moisture levels should not exceed 6 lbs/1,000 sq. ft. (CC) or 75% relative humidity in a 24 hour time period. If test results exceed the limitations, the installation should not proceed until the problem is corrected. See ASTM F 710 for additional information. 8. After installation roll the floor using a 100 lb sectional roller, first in one direction and then in a direction at a right angle to the first line of direction. Remove any excess adhesive when rolling. THE FLOOR MUST BE ROLLED BEFORE THE ADHESIVE HARDENS. 9. Use denatured alcohol or mineral spirits to remove wet adhesive. Do not apply solvents directly to flooring material as a loss of strength/gloss/texture may result. If a tile needs to be cleaned of excess adhesive material on the finished surface, use the solvent sparingly in a slight rubbing manner. Cured adhesive is very difficult to remove. Limitations 10. Store indoors only. Protect from freezing. Adhesive is freeze/thaw stable to 0°F. Prolonged or repeated freeze/thaw cycles should be avoided. Should adhesive freeze, allow to thaw at room temperature and stir well before using. The finished installation must be protected from moisture and/or freezing for a minimum of 24 hours. 11. Allow 8-12 hours for light foot traffic and 2448 hours for heavy foot traffic. 12. Do not wash or wax the floor for a minimum of 48 hours after installation. Apply Adhesive * All Tandus Centiva LVT adhesives meet SCAQMD Rule 1168 TANDUS-CENTIVA.COM 3. Use a high-quality latex/Portland cement based-type patching compound to fill or level any irregular areas. 6. A unit of CENTI 2000 EP consists of two (2) parts labeled Part A and Part B. After opening each container use a can opener to cut the rims off both containers. Thoroughly mix Part A and Part B separately. Combine the two (2) parts making sure that ALL of the contents of one can are added to ALL the contents of the second can. Mix the two parts together thoroughly until they are a uniform color. Immediately after mixing the two parts together, pour the contents into an open, flat pan or on the floor. Epoxy adhesive cures by chemical reaction; the heat generated by that process reduces the open time and curing is accelerated if left in the can. Use a 1⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. 7. Spread the adhesive using a 1⁄16 x 1⁄16 x 1⁄16 inch square notched trowel. After spreading the adhesive lay the tile into it immediately. Check open time periodically by lifting a section just laid to be certain there is transfer of adhesive to the back of the floor covering. The open time will vary with the temperature, humidity, and porosity of the sub-floor. Use a kneeling board or work off of the tile whenever possible. 1701 Mars Hill Road, Florence AL USA 35630 1.888.CENTIVA Tel: 256.767.4990 Fax: 256.760.1763 | S CHÖNOX Roll and Go™ ® Product data sheet 10.67 Rollable Acrylic Adhesive for Luxury Vinyl Tiles suitable for bonding of luxury vinyl tiles (LVT) on suitable substrates in interior areas. Product characteristics EMICODE EC1: very low emission for interior use only solvent free long open time high coverage to be applied with SCHÖNOX Roll and Go™ ROLLER upright application easy to apply low odor can take immediate loading s uitable on underfloor heating systems s uitable on all SCHÖNOX floor leveling compounds, preferably SCHÖNOX AP conforms with MED 96/98/EC Applications SCHÖNOX Roll and Go™ is suitable for bonding of: Luxury Vinyl in Sheets and Tiles following the list of approved LVTs (available on Internet) on SCHÖNOX self leveling compounds or smooth, porous concrete in residential and commercial areas. Requirements of substrate B efore using SCHÖNOX Roll and Go™ prime the thoroughly dried SCHÖNOX self leveling compound (preferably SCHÖNOX AP) or smooth, porous concrete with SCHÖNOX KH FIX following the referring product data sheet. S ubfloors must be smooth, sound, clean, dry and free of any contaminants which may hinder adhesion. S urface treatments or any “friable” areas of the subfloor must be mechanically removed and the subfloor repaired with SCHÖNOX underlayments as required. To ensure an ideal, dust-free surface, vacuum the substrate properly using an industrial vacuum cleaner. W ith subsequent laying of floor coverings on cementitious substrates, where moisture readings are above 85% RH or 6 lbs./1000 sq.ft./24hrs. then application of SCHÖNOX SDG or SCHÖNOX EPA may be used to suppress residual moisture (see data sheet). Always follow the directions of the floor covering manufacturer regarding the maximum allowable moisture content and test the substrate prior to installing SCHÖNOX Roll and Go™. Gypsum screeds should always be dry. Do not use moisture mitigation systems on gypsum substrates. ld water-soluble adhesives should be O removed completely, old water-resistant adhesives should be mechanically removed as far as possible. The complete mechanical removal of cutback (i.e. grinding, sanding, blasting) can be hazardous as old cutback adhesive may contain asbestos. Do not sand or grind adhesive residue. Harmful dust may result. Inhalation of asbestos dust may cause asbestosis or other serious bodily harm. Please consult the adhesive manufacturer and all applicable government agencies for rules and regulations concerning the removal of flooring and adhesives that contain asbestos. Prime remaining adhesive residues accordingly. F ollow the technical product information of the LVT manufacturers regarding specific substrate requirements for their coverings. All slabs on or below grade level must be known to have an intact vapor retarder directly beneath the concrete in conformance to the relevant standards. If in doubt, please contact our SCHÖNOX representative for further advise. O ld, suitable and well fitted coverings should be thoroughly cleaned, sanded, primed and leveled with SCHÖNOX AP. T he requirements of the relevant valid standards, guidelines and data sheets apply. Recommended method of working S CHÖNOX Roll and Go™ is stirred before use. Coverings to be bonded with SCHÖNOX Roll and Go™ should be conditioned, unstressed and in a flat position. Apply SCHÖNOX Roll and Go™ with the SCHÖNOX Roll and Go™ ROLLER evenly on the substrate avoiding pools of adhesive. After fitting the LVT without any bubbles, roll the covering using a metal roller. A second rolling should be done if required at a later stage. Trafficking, loading and polishing of coverings bonded with SCHÖNOX Roll and Go™ can be done immediately. T he replacement of planks/tiles is possible without further substrate preparation using SCHÖNOX Roll and Go™. Replacements are done using the contact method first applying SCHÖNOX | www.schonox.us | Technical data Basis: acrylic dispersion with bonding additives Color: light green Density: 1.0 kg/l storage temperature: not below 41 °F floor temperature: not below 51 °F coverage:- a pprox. 540 sq.ft. per 1.06 gal. unit (as part of the SCHÖNOX ROLL AND GOSet) - a pprox. 2,025 sq.ft. per 3.96 gal. unit waiting time: approx. 10-15 min open time: approx. 2 hours drying time: none, immediately loadable final strength: after approx. 72 hours All values are approximate, are subject to local climatic fluctuations based upon conditions at 70°F with atmosphere of less than 65 % relative humidity following the recommended mixing ratio. Do not install underlayment or topping before the substrate has dried thoroughly. | SCHÖNOX Roll and Go™ ® Roll and Go™ on the backing of the new LVT. After drying to transparency press the covering to the substrate covered with SCHÖNOX Roll and Go™. Remove fresh securing spots by using soapy water, dried spots clean with SCHÖNOX FIX CLEAN. Limited suitability in heavy loaded areas (humidity, temperature) as conservatories. Contact us for further advice. Packaging kg / 1.06 gallons in plastic container as 4 part of the SCHÖNOX Roll and Go™-SET: 1 1 2 1 1 1 SCHÖNOX Roll and Go™ 4 kg/1.06 gal. SCHÖNOX Roll and Go™ ROLLER SCHÖNOX KH FIX 1 kg/0.25 gal. SCHÖNOX KH FIX ROLLER SCHÖNOX HANDLE SCHÖNOX TRAY 15 kg / 3.96 gallons in plastic container Storage and follow all cautions and warnings on product label. For complete safety information, please refer to the Material Safety Data Sheet, or visit our website at www.schonox.us. Limitation of Liability To the best of our knowledge, the technical data contained herein are true and accurate at the date of issuance but are subject to change without prior notice. We guarantee our product to conform to the specifications contained herein. We make no other warranty or guarantee of any kind, express or implied, including merchantability and fitness for particular purpose. Liability, if any, is limited to replacement of the product or refund of the purchase price. Labor or cost of labor and other consequential damages are hereby excluded. SCHÖNOX does not authorize anyone, including SCHÖNOX Representatives, to make any statements which supersede, modify or supplement the information provided on its printed literature or package labels without written confirmation. Product data sheet 10.67 The applicable recommendations, guidelines, regulations and safety data sheets are to be obser ved, together with the recognized architectural and engineering regulations. We guarantee that our products leave the factor y in perfect condition. While our recommendations for use are based on tests and practical experience, they can only provide general guidance without any assurance as to product characteristics, since we have no influence over the conditions on site, the execution of the work or the method of processing. This product data sheet supersedes all previous editions. tore in cool, frost-free conditions. S S helf life: 1 year unopened. Containers that have been opened should be closed immediately. Remove any skin that has formed, do not stir in. Disposal mpty containers and dispose of in E accordance with federal, state and local waste disposal regulations. VOC Content 0g/l (calculated), SCAQMD 1168 LEED Precautions ollow the product data sheets for the F SCHÖNOX supplementary products mentioned and used. If in doubt, please obtain further manufacturer’s information or test in a small area. Avoid eye and skin contact. Close container after each use. Do not reuse container. Do not flush adhesive down drains, sewers or waterways. KEEP OUT OF REACH OF CHILDREN. Carefully read The SCHÖNOX management system is certified to ISO 9001 and 14001 by DQS. SCHÖNOX GmbH P.O. Box 11 40 D-48720 Rosendahl/Germany Phone +49 (0) 2547-910-0 Fax +49 (0) 2547-910-101 [email protected] http://www.schoenox.com In North America provided by: HPS North America, Inc Phone:256.246.0345 Fax:256.246.0346 Email:[email protected] http://www.hpsubfloors.com | Let´s stick together | www.schonox.us | B _1067us_13-10 May help contribute to LEED certification of projects in the categories: IEQ Credit 4.1 Low-Emitting Materials – Adhesives & Sealants 1 point IEQ Credit 4.3 Low-Emitting Materials – Flooring Systems 1 point