scuba tank filling and storage

Transcription

scuba tank filling and storage
SCUBA TANK FILLING AND STORAGE
Tank R ack s , Fill B aths & D ive Resource C enters
Brownie’s designs, builds and installs a variety of
scuba tank storage and filling stations to meet
almost any need. From the most basic tank racks
intended solely to eliminate rolling on deck to the
most elaborate dive support stations equipped
with integrated flat screen monitors and fill whips,
we have a solution to make diving easier and more
efficient onboard. As with Brownie’s other custom
designed systems, a representative will assess each
customer’s diving needs and available space to
ensure a unique, attractive and functional product.
Some examples of available options are fill baths,
vertical and horizontal storage bays, repair benches,
equipment rinse sinks and fill controls.
Installations
HIGH PRESSURE STORAGE/CASCADE SYSTEMS
High P ressure Tank Storage
Brownie’s designs storage systems for air, oxygen,
nitrox, helium or any other specialized gas needed
on your vessel. Valves, regulators, plumbing and
rack construction requirements are all taken into
consideration at the earliest stages of the process. The
result is a system integrated into your vessel.
Storing large volumes of air, nitrox or other gas allows
you to fill your scuba or firefighting scba tanks much
more quickly and efficiently than filling directly from
the compressor. For instance, filling 4 standard scuba
tanks on our YP55 system would take approximately 52
minutes. By contrast, filling the same 4 cylinders from
a cascade system would take less than 5 minutes. This is
especially important for firefighting considerations.
# of Storage Cylinders
GUIDE TO CASCADE SYSTEMS
2
3
4
5
6
Total Volume of stored gas (cubic feet @ 4500 psi)
888
1332
1776
2220
2664
# of direct SCUBA fills without running compressor
(Cascade fill with control valve per storage cylinder)
6
12
17
22
27
# of direct SCUBA fills without running compressor
(Bulk fill from storage without cascade control)
4
6
8
10
12
Actual gas consumed by cascade filling (cubic feet)
400
800
1133
1467
1800
Compressor Model
Free Air Displacement
Time to recharge banks to 4500 PSI
(minutes)
YP45DF
4.1 CFM
98
195
276
358
439
YP55DF
5 CFM
80
160
227
293
360
YP75DF
7 CFM
57
114
162
210
257
YP135DF
11.1 CFM
36
72
102
132
162
Brownie’s