Report: 2662602-02 Project: 2662602 Client: Man-D-Tec PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested SoloBeam 3000K Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 Phone: 480-998-0325 Technical Report Number 2662602-02 September 17, 2013 Prepared by: Approved by: James E. Berkeley, Program Manager Wensheng Xu, Technical Advisor 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 1 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Program Description Photometric and electrical testing of a “SoloBeam 3000K” replacement fixture to IES LM-79-08. Executive Summary Sample Tested = SoloBeam 3000K with housing Luminous Efficacy* (Lumens/Watt) 62.78 Luminous Flux* (Lumens) 268.7 Input Power* (Watts) 4.28 CCT (K)* CRI* 2870.9 81.5 Power Factor* 1.00 Stabilization Time (Light & Power) 30 minutes * The above results are recorded / derived from measurements made using an Integrating Sphere 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 2 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec TABLE OF CONTENTS Sample..................................................................................................................................................................... 4 Test Results ............................................................................................................................................................. 5 Spectral Flux ........................................................................................................................................................... 6 Chromaticity Diagram ............................................................................................................................................ 7 Flux Distribution – Zonal Lumen Summary........................................................................................................... 8 Illuminance Plots .................................................................................................................................................... 9 Candela Plots ........................................................................................................................................................ 10 Candela Tabulation ............................................................................................................................................... 11 Photometric Testing Information .......................................................................................................................... 12 Equipment List: ..................................................................................................................................................... 14 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 3 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Sample The following sample was submitted for evaluation: Man-D-Tec: SoloBeam 3000K SoloBeam 3000K 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 4 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Test Results – The following results were measured after stabilization of the sample in the Integrating Sphere (unless otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power, taken 15 minutes apart, is less than 0.50% (in accordance with IES LM-79-08). Sample Reference Key Photometric Results SoloBeam 3000K Luminous Efficacy (Lumens/Watt) Total Luminous Flux (Lumens) Integrating Sphere 62.78 Goniophotometer 65.77 268.7 280.20 Total Radiant Flux (Watts) 0.920 Correlated Color Temperature (CCT) 2870.9 Color Rendering Index (CRI) (Ra) 81.5 R1 thru R7 Value 80.7 86.7 89.2 79.3 77.5 79.1 89.1 R8 thru R14 Value 70.7 30.5 65.8 73.6 52 81.5 92.9 Chromaticity (Chroma x / Chroma y) 0.4476 / 0.4097 Chromaticity (Chroma u / Chroma v) 0.2550 / 0.3501 Chromaticity (Chroma u’ / Chroma v’) 0.2550 / 0.5252 Duv Value 0.00089 Stabilization Time (Light and Power) Approx. 30 minutes Total Run Time – Integrating Sphere 34 minutes Total Run Time – Goniophotometer 103 minutes 1.06 (0° – 180°) / 1.08 (90° – 270°) Spacing Criteria Scotopic/Photopic ratio Φ(v')/Φ(v) 1.203 Sample Reference Electrical Input Results: SoloBeam 3000K Integrating Sphere 4.28 Goniophotometer 4.26 Input Voltage (Volts DC) 6.80 6.07 Input Current (Amps) 0.70 0.70 0 0 1.00 1.00 Input Power (Watts) Input Frequency (Hertz) Power Factor Total Harmonic Distortion (%THD V/A) N/A Sample Reference Additional Information SoloBeam 3000K Ambient Temperature 24.9°C Integrating Sphere Detector CDS 600 Spectroradiometer Absorption Correction used? Yes 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 5 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Spectral Flux The following graph shows the spectral response curve of the radiant flux for the sample: Spectral response of the Radiant Flux (350nm to 850nm – calibrated range of the Spectroradiometer). 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 6 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Chromaticity Diagram The following image shows the chromaticity diagram for the sample: Tristimulus values (from page 6): x / y = 0.4476 / 0.4097 The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond. 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 7 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Test Results – Flux Distribution – Zonal Lumen Summary The following table depicts the zonal lumen distribution for the sample: Zone Lumens % Total 0 - 10 10 - 20 20 - 30 30 - 40 40 - 50 50 - 60 60 - 70 70 - 80 80 - 90 14.8 40.3 55.5 58.8 51.3 34.6 15.6 6.7 2.6 5.30% 14.40% 19.80% 21.00% 18.30% 12.30% 5.60% 2.40% 0.90% Total 280.2 LUMENS Zone 0-30 0-40 0-60 60-90 0-90 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com 110.5 169.4 255.3 24.9 280.2 This report shall not be reproduced, except in full, without the approval of CSA Group Page 8 of 14 39.50% 60.50% 91.10% 8.90% 100% Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Test Results – Illuminance Plots The following images depict the illuminance characteristics of the luminaire. Beam Angle Field Angle Illuminance Plot (Footcandles) 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 9 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Test Results – Candela Plots The following images depict the luminous intensity distribution characteristics of the luminaire. Isocandela Plot Polar Candela Distribution Coefficients Of Utilization - Zonal Cavity Method RCC %: RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10 80 70 1.19 1.11 1.03 .95 .88 .82 .76 .71 .67 .63 .59 50 1.19 1.07 .96 .86 .78 .71 .64 .59 .54 .50 .47 70 30 1.19 1.04 .90 .79 .70 .63 .57 .51 .47 .43 .40 0 1.19 1.00 .86 .74 .65 .57 .51 .46 .41 .38 .35 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com 70 1.16 1.08 1.00 .93 .86 .80 .75 .70 .65 .61 .58 50 1.16 1.05 .94 .85 .77 .70 .64 .58 .54 .50 .46 50 30 1.16 1.02 .89 .78 .70 .62 .56 .51 .46 .43 .39 0 1.00 .89 .78 .69 .61 .55 .49 .45 .41 .37 .34 50 1.11 1.01 .91 .82 .74 .68 .62 .57 .53 .49 .45 30 1.11 .98 .86 .76 .68 .61 .55 .50 .46 .42 .39 20 1.11 .96 .83 .72 .63 .56 .50 .45 .41 .38 .35 50 1.06 .97 .88 .79 .72 .66 .60 .56 .51 .48 .44 This report shall not be reproduced, except in full, without the approval of CSA Group Page 10 of 14 Effective Floor Cavity Reflectance: 20% 30 30 1.06 .95 .84 .75 .67 .60 .54 .50 .45 .42 .39 10 20 1.06 .93 .81 .71 .63 .56 .50 .45 .41 .37 .34 50 1.02 .93 .85 .77 .70 .64 .59 .54 .50 .47 .44 30 1.02 .92 .82 .73 .65 .59 .54 .49 .45 .41 .38 0 20 1.02 .90 .79 .70 .62 .55 .49 .45 .41 .37 .34 0 1.00 .88 .77 .68 .60 .53 .48 .43 .39 .36 .33 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Test Results – Candela Tabulation The following table provides the tabulated Candela measurements: Candela Table - Type C 0 10 20 30 40 0 158 158 158 158 158 2.5 158 158 158 158 158 5 157 157 157 157 157 7.5 155 155 155 155 156 10 152 152 152 153 152 12.5 148 148 149 149 149 15 144 144 144 145 145 17.5 139 139 139 139 140 20 133 133 134 134 134 22.5 127 127 128 128 128 25 120 121 121 122 122 27.5 113 114 115 115 115 30 106 107 108 109 109 32.5 100 101 102 102 102 35 93 94 95 95 96 37.5 86 88 88 89 89 40 79 80 81 81 81 42.5 72 73 74 74 74 45 65 66 67 67 67 47.5 58 59 59 59 59 50 50 51 52 52 52 52.5 43 43 44 44 44 55 36 36 36 37 37 57.5 29 29 30 30 30 60 23 23 23 23 23 62.5 18 18 18 18 18 65 14 14 13 13 13 67.5 11 11 11 10 10 70 9 9 9 8 8 72.5 7 7 7 7 7 75 6 6 6 6 6 77.5 5 5 5 5 5 80 5 5 5 4 4 82.5 3 3 3 3 3 85 2 2 2 2 2 87.5 1 1 1 1 1 90 1 1 1 1 1 50 158 158 157 155 153 149 145 140 135 128 122 116 109 102 95 88 81 74 67 59 52 44 37 30 23 17 13 10 8 6 5 4 4 3 2 1 1 60 158 158 157 155 153 149 145 140 135 129 122 116 109 102 95 88 81 74 67 60 52 45 37 30 23 17 13 9 7 6 5 4 4 3 2 1 1 70 158 158 157 155 153 149 145 140 135 128 122 116 109 102 95 89 81 74 67 60 52 45 38 30 24 18 13 9 7 6 5 4 4 3 2 1 1 80 158 158 157 155 153 149 145 140 134 129 122 116 109 102 95 89 82 75 67 60 53 45 38 31 24 18 13 10 8 6 5 5 4 3 2 1 1 90 158 158 157 155 152 149 145 139 134 128 122 116 109 102 96 89 82 75 68 61 53 46 39 31 25 19 14 10 8 7 6 5 4 3 2 1 1 100 158 158 157 155 152 148 144 139 134 128 122 115 109 102 96 89 83 76 68 61 54 46 39 32 25 19 14 11 8 7 6 5 5 4 2 1 1 110 158 157 157 155 152 148 144 139 133 128 121 115 109 102 95 89 82 75 68 61 54 46 39 32 25 19 14 11 9 7 6 5 5 4 2 1 1 120 158 157 156 154 151 148 143 138 133 127 121 114 108 101 95 88 81 74 67 60 53 47 42 37 32 26 21 16 11 7 6 5 4 4 2 1 1 130 158 157 156 154 151 147 143 138 132 126 120 114 107 100 93 87 80 73 66 59 52 45 38 31 24 19 14 10 8 7 6 5 4 3 2 1 1 140 158 157 156 154 151 147 143 138 132 126 120 113 106 100 93 86 79 72 65 58 51 44 37 30 24 18 14 10 8 7 6 5 4 3 2 1 1 150 158 156 155 153 151 147 142 137 132 125 119 113 106 99 92 85 78 71 64 57 50 43 36 30 23 18 14 10 8 6 6 5 4 3 2 1 1 160 158 157 155 153 150 146 142 137 131 125 119 112 105 99 92 85 79 71 65 58 51 44 37 30 24 18 14 10 8 7 6 5 4 3 2 1 1 170 158 156 155 153 150 146 142 136 131 125 118 112 106 99 92 86 79 72 65 58 52 44 37 31 24 19 14 11 9 7 6 5 4 4 2 1 1 180 158 158 157 156 153 150 145 140 135 129 122 116 110 103 96 90 84 77 70 63 56 48 41 35 28 22 17 13 10 8 7 6 5 4 3 2 1 190 158 158 157 155 153 149 145 140 134 129 122 116 109 103 97 90 84 77 70 63 56 49 42 35 28 22 17 13 10 8 7 6 5 4 3 2 1 200 158 158 157 155 153 149 145 140 134 128 122 116 109 103 97 90 83 77 70 63 56 49 42 35 29 22 17 13 10 8 7 6 5 5 3 2 1 210 158 158 157 155 152 149 144 139 134 128 122 115 109 102 96 89 83 76 69 62 55 48 42 35 28 22 17 13 10 8 7 6 5 4 3 2 1 220 158 158 157 155 152 149 144 139 133 127 121 115 108 101 95 88 82 75 68 61 55 48 41 35 28 22 17 13 10 8 7 6 5 4 3 1 1 230 158 158 156 155 152 149 144 139 133 127 121 114 108 101 94 87 81 74 67 60 54 47 40 34 28 21 16 12 9 8 7 5 5 4 3 1 1 240 158 158 156 154 152 148 144 139 133 127 120 114 107 100 94 87 80 73 66 60 53 47 40 34 27 21 16 12 9 8 7 5 4 4 2 1 1 250 158 157 156 154 152 148 144 138 133 127 120 114 107 100 93 87 80 73 66 60 53 46 40 34 27 21 16 12 9 8 6 5 4 4 2 1 1 260 158 157 156 154 151 148 143 138 133 126 120 114 107 100 93 87 80 73 66 60 53 46 40 34 27 21 16 12 9 8 6 5 4 4 2 1 1 270 158 157 156 154 151 147 143 138 132 126 120 114 107 100 94 87 81 74 67 60 54 47 40 34 27 21 16 12 10 8 7 6 5 4 2 1 1 280 158 157 156 154 151 148 143 138 132 126 120 114 107 101 94 87 81 74 67 60 54 47 40 34 28 22 16 12 10 8 7 6 5 4 2 1 1 290 158 157 156 154 151 147 143 137 132 126 120 114 107 100 94 87 81 74 67 60 54 46 40 34 27 21 16 12 10 8 7 6 5 4 2 1 1 300 158 157 156 154 151 147 143 137 132 126 120 113 107 100 93 87 80 73 66 60 53 46 39 33 26 20 16 12 9 8 6 5 5 4 2 1 1 310 158 157 155 154 151 148 143 138 132 126 120 113 107 100 93 86 79 72 66 59 52 45 38 32 26 20 15 11 9 7 6 5 4 4 2 1 1 320 158 157 155 154 151 148 143 138 132 126 120 113 106 99 93 86 79 72 65 58 51 44 37 31 25 19 15 11 9 7 6 5 4 3 2 1 1 330 158 156 156 154 151 148 143 138 133 127 120 113 107 100 93 86 79 72 65 58 51 44 37 31 25 19 15 11 9 7 6 5 4 3 2 1 1 340 158 157 156 154 152 148 144 139 133 127 121 114 107 100 93 86 79 72 65 58 51 44 38 31 25 19 15 11 9 7 6 5 4 4 2 1 1 350 158 157 156 154 152 148 144 139 133 127 121 115 108 101 94 87 80 73 66 59 52 45 38 32 25 19 15 12 9 8 6 5 5 4 2 1 1 360 158 158 157 155 152 148 144 139 133 127 120 113 106 100 93 86 79 72 65 58 50 43 36 29 23 18 14 11 9 7 6 5 5 3 2 1 1 Continued…… 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 11 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Photometric Testing Information The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments. The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-7908 and is applicable for all types of LED products (directional and non-directional light projections). Its spectroradiometer is an array-type detector manufactured and calibrated by Labsphere. The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere. Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate any direct optical radiation from the sample under test. Luminaire Stabilization. The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates and electrical power measurements contained in this report are the numeric averages of the three readings upon which stabilization is verified. The stabilization times shown on the results pages of this report denote the time of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is assumed to have taken to reach stabilization. The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications: Manufacturer: Sylvania Model# 75Q/CL-28V Voltage = 28.0 Volt Wattage = 75.0 Watts Calibration Current = 2.679 Amperes Luminous Flux = 1538.8 Lumens Calibration Date = 8-18-2005 (calibrated by Labsphere – NIST traceable). Continued….. 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 12 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Photometric Testing Information (continued) The goniophotometer Mayer Engineering Type C is calibrated using a frosted tungsten filament FDS/DZE lamp with the following specifications: Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-A Voltage: 16.59 Volts DC reference Calibration Current: 4.810 Amperes Luminous Intensity: 154.7 Candelas Calibration Date: 7/12/12 (NIST traceable) Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-B Voltage: 16.61 Volts DC reference Calibration Current: 4.819 Amperes Luminous Intensity: 150.6 Candelas Calibration Date: 7/12/12(NIST traceable) Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-C Voltage: 16.66 Volts DC reference Calibration Current: 4.815 Amperes Luminous Intensity: 155.4 Candelas Calibration Date: 7/12/12 (NIST traceable) A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample. CSA is an accredited Test Laboratory (TL-430) to IESNA LM79-08 by IAS (International Accreditation Service) National Voluntary Laboratory Accreditation Program (NVLAP)200732-0 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 13 of 14 Telephone: 678-992-0134 Fax: 770-500-3948 Report: 2662602-02 Project: 2662602 Client: Man-D-Tec Equipment List: Goniophotometer Type C (Mirror 1) Manufacturer and Description Model Number Optometer Gigahertz Optik P9801 Chroma Instruments 61602PRegulated Power Supply 80-60 Regulated Power Supply Chroma Instruments 61602 Power Analyzer Yokogawa WT210 Equipment List: Sphere C Equipment Manufacturer and Description Model Number Integrating Sphere 76” Labsphere LMS760 Spectroradiometer Labsphere CDS1100 Auxiliary Lamp PSU Labsphere LPS100 Power Analyzer Yokogawa WT210 Regulated Power Supply Chroma Instruments 61603 CSA Instrument Reference Number N/A Calibration Due Date N/A N/A N/A N/A POA400 N/A 11/2013 CSA Instrument Reference Number SPH300 CDS600C LPS100 PA112 AC302 Calibration Due Date N/A N/A N/A 1/2014 N/A All equipment is calibrated to ISO / IEC 17025-2005 guidelines. 6215 Shiloh Crossing Alpharetta, Georgia 30005 www.csagroup.com This report shall not be reproduced, except in full, without the approval of CSA Group Page 14 of 14 Telephone: 678-992-0134 Fax: 770-500-3948
Similar documents
IESNA LM79 Test Report
The sample (UUT) is placed inside the integrating sphere and powered by a regulated and conditioned alternating or direct current supply. The stabilization times shown on the results pages of this ...
More information