SoloBeam 3000K - Man-D-Tec

Transcription

SoloBeam 3000K - Man-D-Tec
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08
Sample Tested
SoloBeam 3000K
Prepared for:
Man-D-Tec
8175 E. Paradise Lane
Scottsdale, AZ 85260
Phone: 480-998-0325
Technical Report Number
2662602-02
September 17, 2013
Prepared by:
Approved by:
James E. Berkeley, Program Manager
Wensheng Xu, Technical Advisor
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 1 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Program Description
Photometric and electrical testing of a “SoloBeam 3000K” replacement fixture to IES LM-79-08.
Executive Summary
Sample Tested = SoloBeam 3000K with housing
Luminous Efficacy*
(Lumens/Watt)
62.78
Luminous Flux*
(Lumens)
268.7
Input Power*
(Watts)
4.28
CCT (K)*
CRI*
2870.9
81.5
Power Factor*
1.00
Stabilization Time
(Light & Power)
30 minutes
* The above results are recorded / derived from measurements made using an Integrating Sphere
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 2 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
TABLE OF CONTENTS
Sample..................................................................................................................................................................... 4
Test Results ............................................................................................................................................................. 5
Spectral Flux ........................................................................................................................................................... 6
Chromaticity Diagram ............................................................................................................................................ 7
Flux Distribution – Zonal Lumen Summary........................................................................................................... 8
Illuminance Plots .................................................................................................................................................... 9
Candela Plots ........................................................................................................................................................ 10
Candela Tabulation ............................................................................................................................................... 11
Photometric Testing Information .......................................................................................................................... 12
Equipment List: ..................................................................................................................................................... 14
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 3 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Sample
The following sample was submitted for evaluation:
Man-D-Tec: SoloBeam 3000K
SoloBeam 3000K
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 4 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Test Results –
The following results were measured after stabilization of the sample in the Integrating Sphere (unless
otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power,
taken 15 minutes apart, is less than 0.50% (in accordance with IES LM-79-08).
Sample Reference
Key Photometric Results
SoloBeam 3000K
Luminous Efficacy (Lumens/Watt)
Total Luminous Flux (Lumens)
Integrating Sphere
62.78
Goniophotometer
65.77
268.7
280.20
Total Radiant Flux (Watts)
0.920
Correlated Color Temperature (CCT)
2870.9
Color Rendering Index (CRI) (Ra)
81.5
R1 thru R7 Value
80.7
86.7
89.2
79.3
77.5
79.1
89.1
R8 thru R14 Value
70.7
30.5
65.8
73.6
52
81.5
92.9
Chromaticity (Chroma x / Chroma y)
0.4476 / 0.4097
Chromaticity (Chroma u / Chroma v)
0.2550 / 0.3501
Chromaticity (Chroma u’ / Chroma v’)
0.2550 / 0.5252
Duv Value
0.00089
Stabilization Time (Light and Power)
Approx. 30 minutes
Total Run Time – Integrating Sphere
34 minutes
Total Run Time – Goniophotometer
103 minutes
1.06 (0° – 180°) / 1.08 (90° – 270°)
Spacing Criteria
Scotopic/Photopic ratio Φ(v')/Φ(v)
1.203
Sample Reference
Electrical Input Results:
SoloBeam 3000K
Integrating Sphere
4.28
Goniophotometer
4.26
Input Voltage (Volts DC)
6.80
6.07
Input Current (Amps)
0.70
0.70
0
0
1.00
1.00
Input Power (Watts)
Input Frequency (Hertz)
Power Factor
Total Harmonic Distortion (%THD V/A)
N/A
Sample Reference
Additional Information
SoloBeam 3000K
Ambient Temperature
24.9°C
Integrating Sphere Detector
CDS 600 Spectroradiometer
Absorption Correction used?
Yes
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 5 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Spectral Flux
The following graph shows the spectral response curve of the radiant flux for the sample:
Spectral response of the Radiant Flux
(350nm to 850nm – calibrated range of the Spectroradiometer).
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 6 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Chromaticity Diagram
The following image shows the chromaticity diagram for the sample:
Tristimulus values (from page 6):
x / y = 0.4476 / 0.4097
The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 7 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Test Results – Flux Distribution – Zonal Lumen Summary
The following table depicts the zonal lumen distribution for the sample:
Zone
Lumens
% Total
0 - 10
10 - 20
20 - 30
30 - 40
40 - 50
50 - 60
60 - 70
70 - 80
80 - 90
14.8
40.3
55.5
58.8
51.3
34.6
15.6
6.7
2.6
5.30%
14.40%
19.80%
21.00%
18.30%
12.30%
5.60%
2.40%
0.90%
Total
280.2 LUMENS
Zone
0-30
0-40
0-60
60-90
0-90
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
110.5
169.4
255.3
24.9
280.2
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 8 of 14
39.50%
60.50%
91.10%
8.90%
100%
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Test Results – Illuminance Plots
The following images depict the illuminance characteristics of the luminaire.
Beam Angle
Field Angle
Illuminance Plot (Footcandles)
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 9 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Test Results – Candela Plots
The following images depict the luminous intensity distribution characteristics of the luminaire.
Isocandela Plot
Polar Candela Distribution
Coefficients Of Utilization - Zonal Cavity Method
RCC %:
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
80
70
1.19
1.11
1.03
.95
.88
.82
.76
.71
.67
.63
.59
50
1.19
1.07
.96
.86
.78
.71
.64
.59
.54
.50
.47
70
30
1.19
1.04
.90
.79
.70
.63
.57
.51
.47
.43
.40
0
1.19
1.00
.86
.74
.65
.57
.51
.46
.41
.38
.35
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
70
1.16
1.08
1.00
.93
.86
.80
.75
.70
.65
.61
.58
50
1.16
1.05
.94
.85
.77
.70
.64
.58
.54
.50
.46
50
30
1.16
1.02
.89
.78
.70
.62
.56
.51
.46
.43
.39
0
1.00
.89
.78
.69
.61
.55
.49
.45
.41
.37
.34
50
1.11
1.01
.91
.82
.74
.68
.62
.57
.53
.49
.45
30
1.11
.98
.86
.76
.68
.61
.55
.50
.46
.42
.39
20
1.11
.96
.83
.72
.63
.56
.50
.45
.41
.38
.35
50
1.06
.97
.88
.79
.72
.66
.60
.56
.51
.48
.44
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 10 of 14
Effective Floor Cavity Reflectance: 20%
30
30
1.06
.95
.84
.75
.67
.60
.54
.50
.45
.42
.39
10
20
1.06
.93
.81
.71
.63
.56
.50
.45
.41
.37
.34
50
1.02
.93
.85
.77
.70
.64
.59
.54
.50
.47
.44
30
1.02
.92
.82
.73
.65
.59
.54
.49
.45
.41
.38
0
20
1.02
.90
.79
.70
.62
.55
.49
.45
.41
.37
.34
0
1.00
.88
.77
.68
.60
.53
.48
.43
.39
.36
.33
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Test Results – Candela Tabulation
The following table provides the tabulated Candela measurements:
Candela Table - Type C
0 10 20 30 40
0 158 158 158 158 158
2.5 158 158 158 158 158
5 157 157 157 157 157
7.5 155 155 155 155 156
10 152 152 152 153 152
12.5 148 148 149 149 149
15 144 144 144 145 145
17.5 139 139 139 139 140
20 133 133 134 134 134
22.5 127 127 128 128 128
25 120 121 121 122 122
27.5 113 114 115 115 115
30 106 107 108 109 109
32.5 100 101 102 102 102
35 93 94 95 95 96
37.5 86 88 88 89 89
40 79 80 81 81 81
42.5 72 73 74 74 74
45 65 66 67 67 67
47.5 58 59 59 59 59
50 50 51 52 52 52
52.5 43 43 44 44 44
55 36 36 36 37 37
57.5 29 29 30 30 30
60 23 23 23 23 23
62.5 18 18 18 18 18
65 14 14 13 13 13
67.5 11 11 11 10 10
70
9
9
9
8
8
72.5
7
7
7
7
7
75
6
6
6
6
6
77.5
5
5
5
5
5
80
5
5
5
4
4
82.5
3
3
3
3
3
85
2
2
2
2
2
87.5
1
1
1
1
1
90
1
1
1
1
1
50
158
158
157
155
153
149
145
140
135
128
122
116
109
102
95
88
81
74
67
59
52
44
37
30
23
17
13
10
8
6
5
4
4
3
2
1
1
60
158
158
157
155
153
149
145
140
135
129
122
116
109
102
95
88
81
74
67
60
52
45
37
30
23
17
13
9
7
6
5
4
4
3
2
1
1
70
158
158
157
155
153
149
145
140
135
128
122
116
109
102
95
89
81
74
67
60
52
45
38
30
24
18
13
9
7
6
5
4
4
3
2
1
1
80
158
158
157
155
153
149
145
140
134
129
122
116
109
102
95
89
82
75
67
60
53
45
38
31
24
18
13
10
8
6
5
5
4
3
2
1
1
90
158
158
157
155
152
149
145
139
134
128
122
116
109
102
96
89
82
75
68
61
53
46
39
31
25
19
14
10
8
7
6
5
4
3
2
1
1
100
158
158
157
155
152
148
144
139
134
128
122
115
109
102
96
89
83
76
68
61
54
46
39
32
25
19
14
11
8
7
6
5
5
4
2
1
1
110
158
157
157
155
152
148
144
139
133
128
121
115
109
102
95
89
82
75
68
61
54
46
39
32
25
19
14
11
9
7
6
5
5
4
2
1
1
120
158
157
156
154
151
148
143
138
133
127
121
114
108
101
95
88
81
74
67
60
53
47
42
37
32
26
21
16
11
7
6
5
4
4
2
1
1
130
158
157
156
154
151
147
143
138
132
126
120
114
107
100
93
87
80
73
66
59
52
45
38
31
24
19
14
10
8
7
6
5
4
3
2
1
1
140
158
157
156
154
151
147
143
138
132
126
120
113
106
100
93
86
79
72
65
58
51
44
37
30
24
18
14
10
8
7
6
5
4
3
2
1
1
150
158
156
155
153
151
147
142
137
132
125
119
113
106
99
92
85
78
71
64
57
50
43
36
30
23
18
14
10
8
6
6
5
4
3
2
1
1
160
158
157
155
153
150
146
142
137
131
125
119
112
105
99
92
85
79
71
65
58
51
44
37
30
24
18
14
10
8
7
6
5
4
3
2
1
1
170
158
156
155
153
150
146
142
136
131
125
118
112
106
99
92
86
79
72
65
58
52
44
37
31
24
19
14
11
9
7
6
5
4
4
2
1
1
180
158
158
157
156
153
150
145
140
135
129
122
116
110
103
96
90
84
77
70
63
56
48
41
35
28
22
17
13
10
8
7
6
5
4
3
2
1
190
158
158
157
155
153
149
145
140
134
129
122
116
109
103
97
90
84
77
70
63
56
49
42
35
28
22
17
13
10
8
7
6
5
4
3
2
1
200
158
158
157
155
153
149
145
140
134
128
122
116
109
103
97
90
83
77
70
63
56
49
42
35
29
22
17
13
10
8
7
6
5
5
3
2
1
210
158
158
157
155
152
149
144
139
134
128
122
115
109
102
96
89
83
76
69
62
55
48
42
35
28
22
17
13
10
8
7
6
5
4
3
2
1
220
158
158
157
155
152
149
144
139
133
127
121
115
108
101
95
88
82
75
68
61
55
48
41
35
28
22
17
13
10
8
7
6
5
4
3
1
1
230
158
158
156
155
152
149
144
139
133
127
121
114
108
101
94
87
81
74
67
60
54
47
40
34
28
21
16
12
9
8
7
5
5
4
3
1
1
240
158
158
156
154
152
148
144
139
133
127
120
114
107
100
94
87
80
73
66
60
53
47
40
34
27
21
16
12
9
8
7
5
4
4
2
1
1
250
158
157
156
154
152
148
144
138
133
127
120
114
107
100
93
87
80
73
66
60
53
46
40
34
27
21
16
12
9
8
6
5
4
4
2
1
1
260
158
157
156
154
151
148
143
138
133
126
120
114
107
100
93
87
80
73
66
60
53
46
40
34
27
21
16
12
9
8
6
5
4
4
2
1
1
270
158
157
156
154
151
147
143
138
132
126
120
114
107
100
94
87
81
74
67
60
54
47
40
34
27
21
16
12
10
8
7
6
5
4
2
1
1
280
158
157
156
154
151
148
143
138
132
126
120
114
107
101
94
87
81
74
67
60
54
47
40
34
28
22
16
12
10
8
7
6
5
4
2
1
1
290
158
157
156
154
151
147
143
137
132
126
120
114
107
100
94
87
81
74
67
60
54
46
40
34
27
21
16
12
10
8
7
6
5
4
2
1
1
300
158
157
156
154
151
147
143
137
132
126
120
113
107
100
93
87
80
73
66
60
53
46
39
33
26
20
16
12
9
8
6
5
5
4
2
1
1
310
158
157
155
154
151
148
143
138
132
126
120
113
107
100
93
86
79
72
66
59
52
45
38
32
26
20
15
11
9
7
6
5
4
4
2
1
1
320
158
157
155
154
151
148
143
138
132
126
120
113
106
99
93
86
79
72
65
58
51
44
37
31
25
19
15
11
9
7
6
5
4
3
2
1
1
330
158
156
156
154
151
148
143
138
133
127
120
113
107
100
93
86
79
72
65
58
51
44
37
31
25
19
15
11
9
7
6
5
4
3
2
1
1
340
158
157
156
154
152
148
144
139
133
127
121
114
107
100
93
86
79
72
65
58
51
44
38
31
25
19
15
11
9
7
6
5
4
4
2
1
1
350
158
157
156
154
152
148
144
139
133
127
121
115
108
101
94
87
80
73
66
59
52
45
38
32
25
19
15
12
9
8
6
5
5
4
2
1
1
360
158
158
157
155
152
148
144
139
133
127
120
113
106
100
93
86
79
72
65
58
50
43
36
29
23
18
14
11
9
7
6
5
5
3
2
1
1
Continued……
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 11 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Photometric Testing Information
The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a
goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments.
The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-7908 and is applicable for all types of LED products (directional and non-directional light projections). Its
spectroradiometer is an array-type detector manufactured and calibrated by Labsphere.
The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the
standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a
halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere.
Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the
integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance
away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate
any direct optical radiation from the sample under test.
Luminaire Stabilization.
The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage
alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates
and electrical power measurements contained in this report are the numeric averages of the three readings upon
which stabilization is verified. The stabilization times shown on the results pages of this report denote the time
of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is
assumed to have taken to reach stabilization.
The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:
Manufacturer: Sylvania
Model# 75Q/CL-28V
Voltage = 28.0 Volt
Wattage = 75.0 Watts
Calibration Current = 2.679 Amperes
Luminous Flux = 1538.8 Lumens
Calibration Date = 8-18-2005 (calibrated by Labsphere – NIST traceable).
Continued…..
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 12 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Photometric Testing Information (continued)
The goniophotometer Mayer Engineering Type C is calibrated using a frosted tungsten filament FDS/DZE lamp
with the following specifications:
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-A
Voltage: 16.59 Volts DC reference
Calibration Current: 4.810 Amperes
Luminous Intensity: 154.7 Candelas
Calibration Date: 7/12/12 (NIST traceable)
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-B
Voltage: 16.61 Volts DC reference
Calibration Current: 4.819 Amperes
Luminous Intensity: 150.6 Candelas
Calibration Date: 7/12/12(NIST traceable)
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-C
Voltage: 16.66 Volts DC reference
Calibration Current: 4.815 Amperes
Luminous Intensity: 155.4 Candelas
Calibration Date: 7/12/12 (NIST traceable)
A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample.
CSA is an accredited Test Laboratory (TL-430)
to IESNA LM79-08 by IAS (International Accreditation
Service)
National Voluntary Laboratory Accreditation Program
(NVLAP)200732-0
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 13 of 14
Telephone: 678-992-0134
Fax: 770-500-3948
Report: 2662602-02
Project: 2662602
Client: Man-D-Tec
Equipment List: Goniophotometer Type C (Mirror 1)
Manufacturer and
Description
Model Number
Optometer
Gigahertz Optik P9801
Chroma Instruments 61602PRegulated Power Supply
80-60
Regulated Power Supply
Chroma Instruments 61602
Power Analyzer
Yokogawa WT210
Equipment List: Sphere C Equipment
Manufacturer and
Description
Model Number
Integrating Sphere 76”
Labsphere LMS760
Spectroradiometer
Labsphere CDS1100
Auxiliary Lamp PSU
Labsphere LPS100
Power Analyzer
Yokogawa WT210
Regulated Power Supply
Chroma Instruments 61603
CSA Instrument
Reference Number
N/A
Calibration Due
Date
N/A
N/A
N/A
N/A
POA400
N/A
11/2013
CSA Instrument
Reference Number
SPH300
CDS600C
LPS100
PA112
AC302
Calibration Due
Date
N/A
N/A
N/A
1/2014
N/A
All equipment is calibrated to ISO / IEC 17025-2005 guidelines.
6215 Shiloh Crossing
Alpharetta, Georgia 30005
www.csagroup.com
This report shall not be reproduced, except in full,
without the approval of CSA Group
Page 14 of 14
Telephone: 678-992-0134
Fax: 770-500-3948