IESNA LM79 Test Report

Transcription

IESNA LM79 Test Report
IESNA LM79-2008 Test Report
TÜV SÜD America
Photometric Testing and Evaluation in Accordance with LM79-2008
Report Prepared for:
David Delgado
Applications Engineer
Maxlite Inc.
12 York Ave.
West Caldwell, NJ 07006
United States
Telephone: (800) 555-5629
Sample Tested:
Sample Description:
Manufacturer:
Technical Report Number:
Report Issue Date:
Total Number of Pages:
LSU4806SU5040 / LSU4806SU50DV40
1x4 Luminaire for Ambient Lighting of
Interior Commercial Spaces
Maxlite, Inc.
JI1402259-04-LM79
March 13th, 2014
11 (including this page)
Report Prepared by:
Report Reviewed by:
Byrd Evans
TÜV SÜD Project Handler
Bryan Cubitt
TÜV SÜD Program Manager
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 1
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Summary of Key Test Results
Model#
LSU4806SU5040/50DV40
Manufacturer Maxlite, Inc.
TÜV Sample# 1260-4
Date of Test March 13th , 2014
Notes: Tested in intended orientation
(Aperture Downward)
Parameter
Luminous Flux
Input Power
Efficacy
C.C.T.
C.R.I. (Ra)
Beam Angle
Stabilization Time
In-Situ Temp Test (ISTMT)**
Measured Result
4,625 Lumens
47.54 Watts
97.28 Lumens/Watt
3864 K
83.2
90.7° (V) / 77.6° (H)
45 minutes
47.1°C (LED)
The above results are recorded / derived from measurements in accordance with LM79-08
**ISTMT in accordance with “Energy Star Program Requirements for Luminaires – Version 1.2”.
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 2
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
TABLE OF CONTENTS
Test Results ..............................................................................................................................................................4
Spectral Flux and Chromaticity Diagram .................................................................................................................5
Zonal Lumen Summary ............................................................................................................................................5
Illuminance Plots......................................................................................................................................................6
Candela Plots ...........................................................................................................................................................6
Candela Tabulation ..................................................................................................................................................7
Candela Tabulation ..................................................................................................................................................8
ISTMT Temperature Measurement .........................................................................................................................9
Photometric Testing Information ..........................................................................................................................10
Equipment List: ......................................................................................................................................................11
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 3
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Test Results –
The following results were obtained after stabilization of the sample in accordance with the requirements set
forth in section 5.0 of IES LM79-2008. Stability is achieved when the variation of 3 readings of light output and
electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.
Photometric Results
Total Luminous Flux (Lumens)
Luminous Efficacy (Lumens/Watt)
Total Radiant Flux (Watts)
Correlated Color Temperature (CCT)
Color Rendering Index (CRI – Ra)
R9 Value
Chromaticity (Chroma x / Chroma y)
Chromaticity (Chroma u / Chroma v)
Chromaticity (Chroma u’ / Chroma v’)
Duv Value
Electrical Results
(120V unless stated otherwise)
Input Power (Watts)
Input Voltage (Volts AC)
Input Current (Amps)
Power Factor @120VAC
Power Factor @277VAC
Input Frequency (Hertz)
A-THD @120VAC (Current %)
A-THD @277VAC (Current %)
Additional Parameters
Stabilization Time (Light and Power)
Test Geometry Configuration
Ambient Temperature
ISTMT (In-Situ Temperature Measurement)
Spacing Criteria
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Maxlite - LSU4806SU5040
Integrating Sphere
Goniophotometer
4625.0
4557.6
97.28
95.94
14.4
3864
83.2
17.0
0.3878 / 0.3849
0.2267 / 0.3375
0.2267 / 0.5062
0.00150
Maxlite - LSU4806SU5040
Integrating Sphere
Goniophotometer
47.54
47.50
120.02
120.04
0.400
0.400
0.989
0.988
0.910
N/A
60.0
60.0
8.24%
8.38%
14.18%
N/A
Maxlite - LSU4806SU5040
Integrating Sphere
Goniophotometer
45 minutes
47 minutes
Type C
4π
24.1°C
24.9°C
47.1°C (LED)
1.24 (0° – 180°) / 1.06 (90° – 270°)
Page 4
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Spectral Flux and Chromaticity Diagram
Spectral Flux
Chromaticity Diagram
Tristimulus values (from page 4):
Spectral response of the Radiant Flux
x / y = 0.3878 / 0.3849
(350nm to 850nm)
The locations on the diagram of the tristimulus
coordinates are indicated by the blue diamond.
Zonal Lumen Summary
Zone
Lumens
% Lamp / Luminaire
0 - 60
60 - 90
0 - 90
90 - 180
0 - 180
3307.6
915.3
4222.9
334.8
4557.8
72.6 %
20.1 %
92.7 %
7.3 %
100.0 %
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 5
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Test Results – Illuminance Plots
The following images depict the illuminance characteristics of the luminaire.
Beam Angle = 90.7° (V) / 77.6° (H)
Field Angle = 141.4° (V) / 172.7° (H)
Test Results – Candela Plots
The following images depict the luminous intensity distribution characteristics of the luminaire:
Isofootcandle Plot
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Isocandela Plot
Polar Candela
Page 6
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Test Results – Candela Tabulation
The table below displays the tabulated Candela measurements from the IES file:
Horizontal (lateral) angles are shown in red across the top of the table, in increments of 22.5°.
Vertical (longitudinal) angles are shown in blue down the side of the table, in increments of 2.5°.
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
37.5
40.0
42.5
45.0
47.5
50.0
52.5
55.0
57.5
60.0
62.5
65.0
67.5
70.0
72.5
75.0
77.5
80.0
82.5
85.0
87.5
90.0
0.0
22.5
45.0
67.5
90.0
112.5
135.0
157.5
180.0
202.5
225.0
247.5
270.0
292.5
315.0
337.5
360.0
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1869
1871
1872
1869
1870
1872
1872
1869
1866
1863
1865
1866
1868
1868
1868
1870
1871
1871
1864
1861
1865
1862
1855
1859
1860
1856
1855
1855
1857
1857
1859
1861
1867
1866
1864
1860
1857
1860
1861
1852
1847
1845
1843
1841
1838
1836
1837
1838
1847
1859
1850
1860
1849
1848
1855
1849
1837
1831
1828
1825
1814
1816
1809
1804
1804
1819
1834
1837
1849
1829
1836
1839
1822
1808
1799
1801
1804
1789
1790
1773
1759
1759
1776
1801
1826
1829
1808
1814
1810
1782
1766
1759
1765
1775
1759
1756
1728
1702
1700
1723
1764
1801
1808
1783
1785
1768
1734
1717
1711
1722
1736
1728
1713
1671
1637
1630
1661
1714
1768
1783
1751
1750
1720
1682
1657
1650
1668
1691
1689
1659
1602
1554
1550
1592
1655
1728
1751
1711
1709
1668
1618
1571
1566
1602
1639
1636
1598
1520
1463
1453
1508
1593
1681
1711
1668
1658
1608
1528
1466
1471
1519
1577
1578
1533
1428
1359
1352
1408
1517
1624
1668
1617
1601
1532
1422
1358
1364
1422
1506
1513
1459
1331
1252
1245
1306
1431
1561
1617
1566
1536
1441
1316
1255
1257
1321
1424
1439
1370
1232
1154
1149
1205
1332
1494
1566
1504
1462
1340
1217
1160
1156
1221
1335
1358
1272
1130
1059
1064
1114
1231
1416
1504
1432
1381
1238
1127
1072
1063
1122
1236
1260
1166
1031
974
990
1033
1138
1333
1432
1349
1295
1141
1045
999
983
1025
1132
1167
1063
936
907
930
962
1046
1239
1349
1256
1204
1050
974
943
920
929
1027
1068
962
849
852
881
905
961
1137
1256
1155
1108
967
918
886
858
842
925
965
867
776
804
845
861
888
1040
1155
1052
1010
891
867
848
809
767
826
861
770
715
771
820
819
821
948
1052
953
914
819
818
822
773
707
726
761
671
661
742
794
782
759
858
953
852
824
756
782
802
746
657
631
662
579
614
717
777
749
706
769
852
757
736
702
753
788
724
606
543
568
498
568
692
762
719
664
683
757
662
652
655
724
775
697
558
459
476
422
523
666
745
690
619
600
662
576
570
604
691
749
670
515
387
388
358
483
636
715
662
570
522
576
494
495
553
659
717
641
476
328
313
305
445
602
678
635
526
451
494
416
424
506
631
674
606
439
280
252
261
411
568
632
608
485
390
416
344
364
463
605
631
570
405
244
209
232
382
531
585
579
447
337
344
285
311
423
576
587
533
374
216
178
209
359
490
542
544
411
294
285
233
268
385
538
541
493
347
197
153
190
334
449
491
503
377
256
233
196
235
353
498
498
453
327
180
140
174
307
400
437
455
348
229
196
178
209
326
452
446
409
305
158
116
153
278
351
383
403
321
204
178
154
187
304
406
397
364
278
144
97
136
244
303
327
350
295
185
154
142
165
276
357
344
313
247
122
72
112
208
254
275
299
263
163
142
113
146
248
308
285
261
212
101
45
89
170
209
230
252
228
143
113
93
125
222
258
234
213
173
76
12
64
137
172
187
211
195
122
93
64
104
193
213
190
173
140
54
1
51
117
147
151
176
163
98
64
41
82
161
172
154
148
118
50
1
46
106
129
141
145
136
74
41
Maximum Candela = 1872 at Horizontal: 112.5°, Vertical: 2.5°
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 7
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
Test Results – Candela Tabulation
The table below displays the tabulated Candela measurements from the IES file:
Horizontal (lateral) angles are shown in red across the top of the table, in increments of 22.5°.
Vertical (longitudinal) angles are shown in blue down the side of the table, in increments of 2.5°.
92.5
95
97.5
100
102.5
105
107.5
110
112.5
115
117.5
120
122.5
125
127.5
130
132.5
135
137.5
140
142.5
145
147.5
150
152.5
155
157.5
160
162.5
165
167.5
170
172.5
175
177.5
180
0.0
22.5
45.0
67.5
90.0
112.5
135.0
157.5
180.0
202.5
225.0
247.5
270.0
292.5
315.0
337.5
360.0
1
59
133
143
138
128
106
46
1
45
97
115
124
129
118
53
1
1
49
114
126
123
115
96
44
1
44
89
109
114
113
107
48
1
1
46
104
112
113
107
88
44
1
43
83
104
109
106
98
47
1
1
43
95
106
109
102
83
43
1
43
77
98
104
101
89
44
1
1
42
85
100
103
94
78
43
2
43
74
91
100
96
82
43
1
1
42
79
94
96
89
73
43
2
42
71
87
95
91
78
42
1
1
41
74
87
92
85
71
43
2
42
68
84
91
86
73
41
1
1
41
70
84
87
82
68
42
2
43
66
81
86
81
69
41
1
1
40
66
81
83
80
65
43
2
42
64
81
84
78
65
41
1
1
41
63
78
81
78
62
42
1
40
62
79
82
77
62
40
1
2
40
60
76
78
76
59
41
2
38
58
77
81
76
60
39
2
1
39
57
74
78
76
57
40
2
37
55
74
80
75
57
38
1
1
38
54
72
78
73
54
39
2
37
52
72
79
74
54
37
1
1
36
52
71
74
71
52
38
2
36
50
70
76
70
51
36
1
2
36
50
66
72
68
50
35
3
33
48
68
73
66
49
35
2
1
37
48
65
70
66
48
31
2
33
46
65
71
63
46
33
1
2
35
46
61
64
62
47
31
2
31
45
62
67
62
43
29
2
2
35
43
58
62
58
45
29
2
33
44
59
64
58
42
29
2
2
31
42
55
58
54
44
28
8
32
44
55
61
54
40
28
2
2
29
41
51
54
50
42
25
5
29
43
51
55
53
40
25
2
3
30
41
47
51
47
40
25
5
28
42
46
50
47
39
24
3
4
31
40
46
48
45
39
24
6
30
41
44
47
43
38
23
4
3
29
39
44
45
43
38
27
8
29
40
43
44
42
36
19
3
4
26
39
43
43
43
36
27
7
27
40
42
42
41
34
20
4
5
26
38
42
42
42
34
23
4
26
39
42
42
41
33
18
5
4
23
36
41
42
42
34
23
7
25
38
41
42
40
32
17
4
6
22
35
41
42
40
31
23
8
22
36
41
40
37
29
15
6
5
22
33
39
40
38
31
21
7
19
34
40
39
35
27
15
5
5
18
31
38
39
36
27
21
6
17
33
38
36
31
25
16
5
6
19
29
34
38
35
22
19
8
16
31
37
30
28
21
13
6
6
16
25
32
36
33
21
14
7
14
26
33
23
23
19
12
6
6
14
22
28
31
29
20
14
8
15
21
24
19
20
15
11
6
7
12
17
21
24
25
23
12
7
11
15
19
17
18
12
8
7
5
10
14
15
17
17
14
11
9
9
11
13
12
12
9
8
5
6
7
8
9
9
9
9
8
9
5
7
8
8
7
7
6
6
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 8
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
ISTMT Temperature Measurement
ISTMT temperature measurement at thermal stabilization (8 hours continuous operation).
Thermocouple locations (shown below) are in accordance with manufacturers recommended / stated
guidelines for TMP - Temperature Measurement Point.
“LED” Thermocouple location at TMP
Test Results for
Maxlite- LSU4806SU5040
47.1°C
LED TMP Temperature
All temperatures are normalized to 25°C ambient.
Test Equipment
Description
Thermometer
Manufacturer / Model#
Fluke 52-II
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
TÜV SÜD Ref#
ATLE0118
Calibration Due Date
1/16/2015
Page 9
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
TÜV SÜD Photometric Testing Information
Testing is performed in accordance with the procedures outlined in IESNA LM79-2008. The sample is
evaluated for photometric and electrical characteristics using an integrating sphere and a goniophotometer,
located in an accredited, temperature and humidity-controlled, draft free photometric laboratory.
Sphere Geometry
The integrating spheres used for measurement utilize a “4π geometry” configuration in accordance with
section 9 of IES LM-79-2008 and is applicable for all types of SSL products (directional and non-directional light
projections). The spectroradiometer is an array-type detector manufactured and calibrated by Labsphere
(Model# CDS1100).
Self-Absorption Correction
The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the
standard reference lamp and the test samples being measured. This auxiliary correction lamp is a halogen type
lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere (model LPS150).
Ambient temperature is measured using a thermocouple located inside the integrating sphere at the same
height as the sample under test (UUT) and not more than 1 meter in horizontal distance away from the sample
(section 2.2 of LM79-2008). The thermocouple is located behind a baffle in order to eliminate any direct
optical radiation from the sample under test.
Sample Stabilization
The sample (UUT) is placed inside the integrating sphere and powered by a regulated and conditioned
alternating or direct current supply. The stabilization times shown on the results pages of this report denote
the time of the 3rd measurement (of the 3 consecutive readings) since this is the minimum time that the
sample is assumed to have taken to reach stabilization in accordance with section 5.0 of LM79-2008.
Sphere Calibration
The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:
Manufacturer: EYE Lighting International
Model# J94/JD28V75W
Voltage = 28.0 Volts DC
Wattage = 75.0 Watts
Calibration Current = 2.679 Amperes
Luminous Flux = 1685 Lumens
Calibration Date = 2-17-2011 (calibrated by Labsphere – NIST traceable).
Continued…..
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19
Page 10
NRG_F_10.04
Confidential Report
Lab Code: 500065-0
TÜV SÜD America is
accredited under the
NVLAP EEL program.
Report# JI1402259-04-LM79
IESNA LM79-2008
TEST REPORT
March 13, 2014
TÜV SÜD Photometric Testing Information (continued)
Goniophotometer
The Goniophotometer is a Mirror based Type C optical measurement system in accordance with section 9.3.1
of IESNA LM79-2008.
Goniophotometer Calibration
The Goniophotometer is calibrated using a frosted tungsten filament FDS/DZE lamp with the following
specifications:
Manufacturer: General Electric
Part Number: CSB-110
Lamp Number: 112-A
Voltage: 16.52 Volts DC
Wattage: 150.0 Watts
Calibration Current: 4.816 Amperes
Luminous Intensity: 151.5 Candelas
Calibration Date: 02-13-2011 (NIST traceable)
TÜV SÜD Test Equipment List:
TÜV SÜD Sphere System – contains the following:
Description
Manufacturer / Model#
Integrating Sphere
Labsphere LM760
Spectroradiometer
Labsphere CDS1100
Power Analyzer
Yokogawa WT210
Power Source
Chroma 61602
Thermometer
Fluke 52-II
TÜV SÜD Ref#
SPH003
ATLE0048
ATLE0058
AC003
ATLE0008
TÜV SÜD Mirror Goniophotometer System – contains the following:
Goniophotometer
M.E. GONC02
GON002
Spectroradiometer
Gigahertz Optik P9801
GIG002
Power Analyzer
Yokogawa WT210
ATLE0031
Power Source
Chroma 61603
AC007
Calibration Due Date
weekly
9/7/2016
3/7/2014
N/A
11/17/2014
Weekly
Weekly
11/16/2014
N/A
This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single
examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.
This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government
TÜV SÜD America, Inc.
5945 Cabot Parkway, Suite 100,
Alpharetta GA 30005
Telephone: 678-341-5900 www.tuvamerica.com
NRG_F_10.04, Rev. 0, Effective: 2012-01-19