THE MENTAL HEALTHCARE LIGHTING CHALLENGE
The principal requirement
for Mental Healthcare lighting
has historically been to provide
safe and secure, anti-ligature
luminaires. The modern need
is to combine these elements
with a design that provides
a domestic quality and an
ambiance that promotes
rehabilitation and recovery,
whilst heeding the need
for energy efficiency.
2
www.thorlux.com
LED GUIDE
Thorlux designs, manufacturers and tests the vast majority of its own
LED electronic systems including the lenses for precise optical control.
We carefully consider end of life scenarios, for example, LED failures,
solder joint failures and isolated component failures to ensure new
designs have on-going system reliability even when individual
components fail.
Our 79 year company history, running into thousands of years
of combined experience, ensures every aspect of lighting a space
is carefully considered - a requirement all the more important as
LED lifetimes are now expected to reach 50,000 to 100,000 hours
or even more!
EXAMPLE:
LEDs have developed significantly now exceeding the performance
of even the best fluorescent solutions. Volume increases have reduced
costs, making them the ideal choice in many more applications. Not all
LED solutions are the same so Thorlux has introduced a simple marking
code into its literature to identify the key performance characteristics
of its LED based luminaires - an example is shown to the right.
LED CHARACTERISTICS
Ra
80+
LED characteristics are shown on web catalogue download pages
and show the best performance expected within the range. Please
check photometric data for specific model types which may be less
than the optimum figure tabulated.
P/U
P
°K
4000
%
>85
L70/B10
60K
R/Rx
R
Ra
%
Indicates colour rendering index (colour quality). A minimum
of Ra 80 is recommended for working areas.
This figure illustrates the LED driver efficiency.
°K
The approximate colour temperature of the light source. There will
be a band at which the LEDs are chosen from around this target figure.
More accurate information, for specialist applications, is available
upon request.
L70/B10
These figures illustrate the target life expectancy of the LED (for
example 60K = 60,000 hour life expectancy) which is a combination
of light output degradation (L70 = when the light output has reduced
to 70% of its initial level) and lamp failure expectation (B10 = when
10% of the LEDs have failed to meet operational expectations).
PF
>0.9
LL/CW
101.7
R/Rx
When the LED fails, some luminaires require replacement in their
entirety (Rx) some have replaceable LED “lamp” assemblies (R).
PF
Indicates LED driver power factor.
LL/CW
Luminaire lumens per circuit watt, the luminaire efficiency including
ALL optical and gear losses. It is very important to compare this
figure correctly - other manufacturers may state LED efficiency,
for example, which does not include all losses within the system
and could therefore be a misleading, much higher figure.
P/U
Some LED “lamps” comprise a number of LEDs connected in series
or in a series/parallel group. If the system is protected (P) then failure
of a single LED will not affect others in the group. If the system
is unprotected (U) failure of one LED will cause others in the group
to extinguish.
www.thorlux.com
3
CLEANLINE
LED TAMPER-RESISTANT AND IMPACT RESISTANT
RECESSED LUMINAIRES
RANGE
NOMINAL
SIZE
IP20
APPROX.
LED
CAT. No.
kg
CIRCUIT
26W CZ 17002T7.2
600 x 600
38W CZ 17003T7.2
ABOVE CEILING
IP65
BELOW CEILING
LED IK10
SPECIFICATION
• Steel body finished full polyester, non-yellowing
white
• Quick release extruded aluminium cover frame
L/A
L/A
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. CZ 17002LT etc.
• Cover seals to ceiling with FDA approved silicone
gasket
EMERGENCY VERSION - prefix catalogue number with:
ECZ - Emergency / TCZ - AutoTest e.g. ECZ 17002LT etc.
Emergency and AutoTest versions add 0.3kg to weights listed.
Tamper-resistant screw fixings
(Requires key - see Accessory table below)
l
• Fits most suspended ceiling types or cut apertures
• Fitted with 4000K LEDs
PHOTOMETRIC GUIDE
TRANSVERSE
AXIAL
LED CHARACTERISTICS
DIMENSIONS
TRANSVERSE
AXIAL
572
TRANSVERSE
AXIAL
TRANSVERSE
Ra
80+
P/U
101
%
>85
L70/B10
60K
AXIAL
LL/CW
TRANSVERSE
R/Rx
R
PF
106.7
>0.95 100
100
100
60
60
200
200
120
120
180
180
300
240
240
400
300
400
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
26W = 3200lm
38W = 4490lm
300
522
603
400
181
CANDELAS PER 1000 LUMENS
CANDELAS PER 1000 LUMENS
120
603
All dimensions in millimetres
4
P
°K
AXIAL
4000
www.thorlux.com
21mm dia.
mains entry
hole
For LED characteristics explanation
200 see page 3
CANDELAS PER 1000 LUMENS
ACCESSORY
DESCRIPTION
Tamper-resistant key
CANDELAS PER 1000 LUMENS
CAT. No.
KEY 12152
G4 : AL
SQUARE LED RECESSED DOWNLIGHTERS
IP20
IP40
ABOVE CEILING
BELOW CEILING
LED IK10
SPECIFICATION
• Steel frame finished full polyester satin white
(RAL 9016)
• Injection moulded reflector
• Choice of optics optimised for general area,
corridor and low glare (VDT)
• Clear 4mm thick polycarbonate front cover
• Die-cast sprung suspension arms for rapid installation
• Supplied with remote gear unit fitted with 2m lead
• Tamper-resistant pin Torx screw fixings
(Requires T20 tool - see Accessories table below)
• Optional reinforcing board with centre cut aperture
• Emergency, AutoTest and Scanlight AT versions
using integral, high power 1.5W LED
RANGE
• 16W and 32W very high efficiency versions
GENERAL AREA
LED
VERSION
• Fitted with 4000K LEDs
16W
32W
LED CHARACTERISTICS
Ra
80+
P/U
P
°K
LL/CW
60K
%
R/Rx
>85
>0.9
CIRCUIT
GF 163632.6 L/A
GF 163642.6 L/A
e.g. GF 16359L etc.
EMERGENCY VERSION - prefix catalogue number with:
EGF - Emergency / TGF - AutoTest / DGF - Scanlight AT e.g. EGT 16359L etc.
Emergency, AutoTest and Scanlight AT versions add 0.3kg to weights listed.
70.0
PF
R
GF 16361
GF 16362
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI)
L70/B10
4000
GF 16359
GF 16360
CORRIDOR LOW GLARE APPROX.
VERSION VERSION
kg
For LED characteristics explanation see page 3
ACCESSORIES
DIMENSIONS
DESCRIPTION
CAT. No.
81
86
200
APPROX.
kg
597 x 597mm ceiling reinforcing board
(3mm thick plywood with 185 x 185mm central cut-out)
GF 151450.55
T20 pin Torx bit
(Suitable for magnetic bit holder)
KEY 16975
-
200
PHOTOMETRIC GUIDE
Cut-out - 185 x 185
Minimum void depth - 115
TRANSVERSE
Remote Driver
31
179
31
100
150
280
200
300
420
300
450
400
600
AXIAL
560
LED Downlighter Power Unit
55
272
140
115
CANDELAS PER 1000 LUMENS
CANDELAS PER 1000 LUMENS
CANDELAS PER 1000 LUMENS
CORRIDOR - PLAIN
GENERAL AREA - PLAIN
LOW GLARE LENS - PLAIN
Luminaire Lumen Output
16W = 1200lm
32W = 2360lm
Luminaire Lumen Output
16W = 1260lm
32W = 2455lm
Luminaire Lumen Output
16W = 750lm
32W = 1470lm
All dimensions in millimetres
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
5
G3 : AL
CIRCULAR LED RECESSED DOWNLIGHTERS
IP20
ABOVE CEILING
IP65
BELOW CEILING
LED IK10
SPECIFICATION
• Steel ring finished full polyester satin white (RAL 9016)
• Extruded aluminium heat sink
• Injection moulded reflector
• Choice of 4mm thick clear or satin polycarbonate
front cover
• Supplied with remote gear unit fitted with 2m lead
• Tamper-resistant pin Torx screw fixings
(Requires T20 tool - see Accessories table below)
• Optional reinforcing board with centre cut aperture
RANGE
LED
CLEAR
SATIN
VERSION VERSION
12W
24W
GT 16550
GT 16551
• Emergency, AutoTest and Scanlight AT versions
using integral, high power 1.5W LED
APPROX.
kg
CIRCUIT
• 12W and 24W very high efficiency versions
GT 165523.0 L/A
GT 165533.0 L/A
• Fitted with 4000K LEDs
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. GT 16550L etc.
LED CHARACTERISTICS
EMERGENCY VERSION - prefix catalogue number with:
EGT - Emergency / TGT - AutoTest / DGT - Scanlight AT
e.g. EGT 16550L etc.
Emergency, AutoTest and Scanlight AT versions add 0.3kg to weights listed.
Ra
80+
P/U
P
°K
4000
%
>85
L70/B10
LL/CW
60K
R/Rx
72.9
PF
R
>0.9
For LED characteristics explanation see page 3
ACCESSORIES
DESCRIPTION
CAT. No.
APPROX.
kg
597 x 597mm ceiling reinforcing board
(3mm thick plywood with 185mm diameter
central cut-out)
GT 119700.55
T20 pin Torx bit
(Suitable for magnetic bit holder)
KEY 16975
-
DIMENSIONS
Remote Driver
PHOTOMETRIC GUIDE
123
118
31
179
31
206 dia.
100
100
200
200
300
300
400
400
CANDELAS PER 1000 LUMENS
6
CANDELAS PER 1000 LUMENS
CLEAR POLYCARBONATE
SATIN POLYCARBONATE
Luminaire Lumen Output
12W = 1020lm
24W = 1990lm
Luminaire Lumen Output
12W = 870lm
24W = 1690lm
WEB LINKS
thorlux.com/scanlight-at
LED Downlighter Power Unit
55
272
Cut-out - 180 dia.
Minimum void depth - 115
All dimensions in millimetres
115
G2 : AL
RECESSED LOW WATTAGE LED DOWNLIGHTERS
WITH REMOTE CONTROL GEAR
IP20
IP43
ABOVE CEILING
BELOW CEILING
LED IK09
SPECIFICATION
• High pressure die-cast bezel finished full polyester
satin white (RAL 9016)
• Injection moulded polycarbonate body housing
• Choice of 3mm thick prismatic polycarbonate
or satin polycarbonate lens
• Remote phosphor mixing chamber
• Supplied with remote gear unit fitted with 2m lead
• Tamper-resistant pin Torx screw fixings
(Requires T10 tool - see Accessory table below)
• Fitted with 4000K LEDs
Ra
P/U
P
°K
L70/B10
4000
LL/CW
60K
%
R/Rx
>85
R
LED
SATIN
PRISMATIC
POLYCARBONATEPOLYCARBONATE APPROX.
VERSION
VERSION
kg
CIRCUIT
GU 16834
GU 16836
6W
12W
LED CHARACTERISTICS
80+
RANGE
41.6
PF
>0.9
GU 16835 0.5L/A
GU 16837 0.5L/A
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. GU 16834L etc.
EMERGENCY VERSION - prefix catalogue number with:
EGU - Emergency / TGU - AutoTest / DGU - Scanlight AT e.g. EGU 16834LT etc.
Emergency, AutoTest and Scanlight AT versions add 0.4kg to weights listed.
For LED characteristics explanation see page 3
ACCESSORY
DESCRIPTION
CAT. No.
KEY 16974
T10 pin Torx bit (Suitable for magnetic bit holder)
PHOTOMETRIC GUIDE
DIMENSIONS
74
100
15mm deep
ceiling
111
Cut out - 89 dia.
Minimum void depth
for emergency and AutoTest
versions - 165
100
200
200
400
300
600
400
800
CANDELAS PER 1000 LUMENS
CANDELAS PER 1000 LUMENS
SATIN LENS
PRISMATIC LENS
Luminaire Lumen Output
6W = 315lm
12W = 625lm
Luminaire Lumen Output
6W = 305lm
12W = 610lm
All dimensions in millimetres
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
7
ARCADIAN
LED ANTI-LIGATURE LUMINAIRES
IP65 LED
IK10++
SPECIFICATION
• Spun strong steel body
• 5mm polycarbonate cover moulding with white
trim as standard
• Anti-ligature design
• Anti-pick mastic can be used to seal the body whilst
still allowing the cover to be removed for maintenance
• Other colour trim options available to special order
• Tamper-resistant pin Torx screw fixings
(Requires T30 tool - see Accessory table below)
• Circadian tunable white version available
• Microwave presence detector option with stand-by
light level feature
• Standard versions fitted with 3000K or 4000K LEDs.
Tunable white version fitted with 3000-6500K LEDs
LED CHARACTERISTICS - Standard
RANGE
LED
3000/
4000
P/U
%
>85
P
APPROX.
CAT. No.
kg
CIRCUIT
Standard version
21W 3000K
21W 4000K
°K
Ra
80
L70/B10
60K
R/Rx
R
PF
0.95
LL/CW
90.2
LED CHARACTERISTICS - Tunable
AN 170743.1 L/A
AN 170753.1 L/A
Tunable white version
21W 3000-6500K
AN 170763.1 L/A
°K
Ra
30006500
P/U
%
>85
80
P
L70/B10
60K
R/Rx
R
PF
0.95
LL/CW
85.2
For LED characteristics explanation see page 3
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. AN 17074L etc.
EMERGENCY VERSION - prefix catalogue number with:
EAN - Emergency / TAN - AutoTest / DAN - Scanlight AT
e.g. EAN 17074L etc.
AutoTest and Scanlight AT versions add 0.3kg to weights listed.
DIMENSIONS
445 dia.
138
354
8 x fixing holes
INTEGRAL NIGHT LIGHT VERSION - suffix catalogue number with:
N e.g. AN 17074LN etc.
354
PHOTOMETRIC GUIDE
TRANSVERSE
EASY COVER REMOVAL
Rear conduit entry
AXIAL
All dimensions in millimetres
Anti-pick
sealant
100
ACCESSORY
200
DESCRIPTION
300
400
Secure
fixed
body
Cover
CAT. No.
T30 pin Torx bit (Suitable for magnetic bit holder)
KEY 16977
CANDELAS PER 1000 LUMENS
OPTION
Luminaire Lumen Output
21W 3000/4000K = 2255lm
21W 3000-6500K = 2130lm
DESCRIPTION
Microwave presence detector
8
WEB LINKS
thorlux.com/scanlight-at
thorlux.com/microwave
SUFFIX
MD
EXAMPLE
AN 17074MD
COBALT : AL
CIRCULAR SURFACE LED LUMINAIRES
IP66 LED IK10
SPECIFICATION
• Strong die-cast aluminium body and spun
aluminium cover frame finished full polyester
satin white (RAL 9016) as standard
• Silver finish option
•Satin polycarbonate front cover
• Tamper-resistant pin Torx screw fixings
(Requires T30 tool - see Accessory table below)
• Fitted with 4000K LEDs
LED CHARACTERISTICS
Ra
80
P/U
P
°K
4000
%
>90
L70/B10
60K
R/Rx
R
PF
0.95
LL/CW
87.6
RANGE
APPROX.
CAT. No.
kg
CIRCUIT
LED
For LED characteristics explanation see page 3
CT 161143.4 L/A
16W
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. CT 16114L etc.
DIMENSIONS
355 dia.
SILVER OPTION - add suffix SV3
115
220
63
All dimensions in millimetres
Fixings:
4 x Spot faces,
drill as required
220
T30 pin Torx bit (Suitable for magnetic bit holder)
EMERGENCY VERSION - prefix catalogue number with:
ECT - Emergency / TCT - AutoTest / DCT - Scanlight AT
e.g. ECT 16114L etc.
Emergency, AutoTest and Scanlight AT versions add 0.3kg
to weights listed.
Rear conduit entry:
1 x Spotface,
drill as required
PHOTOMETRIC GUIDE
ACCESSORY
DESCRIPTION
e.g. CT 16114LSV3 etc.
CAT. No.
KEY 16977
420
420
280
280
140
140
140
140
280
280
420
CANDELAS PER 1000 LUMENS
420
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
16W = 1665lm
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
9
CLEANLINE
VENTEGO
LED TAMPER-RESISTANT AND IMPACT RESISTANT
SURFACE LUMINAIRES
IP65 LED
IK10++
SPECIFICATION
• Robust and durable extruded aluminium body
finished white (RAL 9010)
• Die cast aluminium end caps finished white
(RAL 9010)
• Clear prismatic polycarbonate lens
• Body dissipates heat, ensuring long control gear
life in higher ambient temperatures
• Suitable for both individual and in-line mounting
• Fitted with 4000K LEDs
LED CHARACTERISTICS
RANGE
LENGTH
(mm)
APPROX.
LED
CAT. No.
kg
697
1307
19W
56W
Ra
CIRCUIT
80
P/U
VT 172155.0 L/A
VT 172169.0 L/A
P
EMERGENCY VERSION - prefix catalogue number with:
EVT - Emergency e.g. EVT 17215L etc.
Emergency versions add 0.3kg to weights listed.
TRANSVERSE
DIMENSIONS
AXIAL
64
80
160
240
320
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
19W = 1450lm
56W = 4150lm
10
www.thorlux.com
%
>85
L70/B10
70K
R/Rx
R
PF
0.95
LL/CW
66.0
For LED characteristics explanation see page 3
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. VT 17215L etc.
PHOTOMETRIC GUIDE
°K
4000
260
697 - 19W
1307 - 56W
All dimensions in millimetres
A-LINE : AL
MULTI-PURPOSE, CORROSION-RESISTANT
LED LUMINAIRES
IP65 LED IK10
SPECIFICATION
• Robust and durable extruded aluminium body
with die-cast ends finished full polyester,
non-yellowing white
• Body dissipates heat, ensuring long control gear
life in higher ambient temperatures
• High impact-resistant textures, flame retardant
polycarbonate cover
• Tamper-resistant cover screws (Tool supplied)
• Removable gear tray, hangs on safety straps
for easy maintenance
• Available with 1W LED night light
• Fitted with 4000K LEDs
RANGE
LED CHARACTERISTICS
Ra
80+
P/U
P
°K
L70/B10
4000
60K
%
R/Rx
>85
R
PF
>0.95
NOMINAL
SIZE (mm)
LL/CW
130.3
For LED characteristics explanation see page 3
1500
LAMP
CAT. No.
29W LED
58W LED
LENGTH (mm)
APPROX.
kg
CIRCUIT
AL 16111 8.1 L/A
1598
AL 16110
8.1 L/A
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. AL 16111L etc.
EMERGENCY VERSION - prefix catalogue number with:
EAL - Emergency / TAL - AutoTest / DAL - Scanlight AT e.g. EAL 16111L etc.
Emergency, AutoTest and Scanlight AT versions add 0.3kg to weights listed.
INTEGRAL NIGHT LIGHT VERSION - suffix catalogue number with:
N e.g. AL 16111LN etc.
DIMENSIONS
121
158
All dimensions in millimetres
PHOTOMETRIC GUIDE
TRANSVERSE
AXIAL
80
160
240
320
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
29W = 3050lm
58W = 6100lm
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
11
VANDALUX
LED VANDAL-RESISTANT SEALED LUMINAIRES
IP65 LED IK10
SPECIFICATION
• 1.0mm steel body finished full polyester powder
coated textured black
• 1.5mm steel front cover frame retained with
tamper-resistant captive fixings (key supplied)
• White finish option
• Satin diffusing, 5mm thick polycarbonate front cover
• Continuous mounting available using infills
• Complies with M.O.D. JSP482 Document for
‘Category C’ areas
• High impact strength - IK10
• Tamper-resistant pin hex screw fixings
(Requires tool - see Accessories table below)
• Safe cell prison versions available (see below)
• Fitted with 4000K LEDs
RANGE
NOMINAL
SIZE (mm)
APPROX.
LED
CAT. No.
kg
CIRCUIT
34W
VN 1575813.0 L/A
1500
74W
VN 1575913.2 L/A
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. VN 15758L etc.
WHITE OPTION - add suffix W3
e.g. VN 15758LW3 etc.
LED CHARACTERISTICS
°K
Ra
80+
4000
P/U
%
90
P
L70/B10
60K
R/Rx
R
PF
>0.95
LL/CW
84.5
EMERGENCY VERSION - prefix catalogue number with:
EVN - Emergency / TVN - AutoTest / DVN - Scanlight AT e.g. EVN 15758L etc.
Emergency, AutoTest and Scanlight AT versions add 0.3kg to weights listed.
For LED characteristics explanation see page 3
ACCESSORIES
DIMENSIONS
DESCRIPTION
APPROX.
CAT. No.
kg
1500mm Infill (for use with continuous mounting)
VN 13327
Key for 3mm tamper-
resistant screws
KEY 13328
174
1616
174
13.6
5
23
NOTE: Supply entries and fixing points to be drilled on site
IP65 integrity must be maintained
All dimensions in millimetres
Infill - VN 13327
12
WEB LINKS
thorlux.com/scanlight-at
SAFE CELL
Version available to special order with National
Offender Management Service (NOMS) approval
for use in Prison “Safer Cells”. Contact our Sales
Department for details
REALTA MICRO
3W silver version
LOW LIGHT LEVEL, WALL MOUNTED LUMINAIRES
IP66 LED TC-S
IK10++
6W graphite version
SPECIFICATION
• Graphite full polyester powder finish
• Silver or white options
• White polyester powder coated internal gear tray/
reflector
• Strong die-cast LM24 aluminium body
• One piece injection moulded UV stabilised
polycarbonate cover
RANGE
LAMP
CAT. No.
APPROX.
kg
3W LED
RL 13543L1.3
• Hex fixings for cover and wall bracket
6W LED
RL 16607L1.5
MAINS
• Compact fluorescent or LED lamp sources
• Fitted with 4000K lamp or LEDs
LED CHARACTERISTICS
°K
80
4000
P/U
%
80
P
L70/B10
LL/CW
60K
R/Rx
R
PF
0.5
60.6
DIMENSIONS
ERL 135421.3
5W TC-S
3W LED s
TRL 13543L
6W LED
TRL 16607L
SCANLIGHT AT
For LED characteristics explanation see page 3
AUTOTEST
Ra
EMERGENCY
NON
APPROX.
LAMP
MAINTAINEDMAINTAINED
kg
1.3
TRL166081.5
3W LED s
DRL 13543L
6W LED
DRL 16607L
1.3
DRL166081.5
CIRCUIT TYPE - L - non-dimming (LED)
134
COLOUR OPTIONS -Silver add suffix SV3 e.g. RL 13543LSV3 etc.
White add suffix W12 e.g. RL 13543LW12 etc.
s
Can be wired during installation for maintained or non-maintained operation
130
137
260
1 x 21 dia.
cable entry hole
(IP 66 grommet
supplied)
47
32
ACCESSORY
DESCRIPTION
CAT. No.
Wall mounting kit for 20mm conduit
(side entry only)
RL 15419
APPROX.
kg
0.4
COLOUR OPTIONS -Silver add suffix SV3 e.g. RL 15419SV3 etc.
White add suffix W12 e.g. RL 15419W12 etc.
100
All dimensions in millimetres
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
13
REALTA
REALTA
PHOTOMETRIC GUIDE
PERFORMANCE GUIDE - Wide Distribution
POLYCARBONATE COVER - 18W LED
(Wide Distribution)
Photometric Performance 18W LED with polycarbonate cover
D.L.O.R. 98%
Spacing
U.L.O.R. 2%
SPACING
300
120
600
240
3m mounting height - 3m forward throw
10m ctrs
15m ctrs
20m ctrs
900
360
CANDELAS PER 1000 LUMENS
CANDELAS PER 1000 LUMENS
POLYCARBONATE COVER - 32W LED
(Area Distribution)
D.L.O.R. 98%
U.L.O.R. 2%
120
18 lux
12 lux
10 lux
0.53
0.49
0.35
Mounting
height
4m mounting height - 4m forward throw
Luminaire Lumen Output
18W = 1430lm
AVERAGEUNIFORMITY
ILLUMINANCE
(min/av)
10m ctrs
15m ctrs
20m ctrs
15 lux
9 lux
7 lux
0.64
0.55
0.49
Forward throw
5m mounting height - 5m forward throw
10m ctrs
15m ctrs
20m ctrs
10 lux
7 lux
5 lux
e.g. At 3m mounting height and
10m centres: 18 lux average
horizontal illuminance
at ground level
0.56
0.49
0.55
FIGURES ARE BASED ON INITIAL LUMENS
240
360
CANDELAS PER 1000 LUMENS
Luminaire Lumen Output
32W = 2700lm
ACCESSORY
DESCRIPTION
Key for 4mm tamper-resistant screws
14
www.thorlux.com
CAT. No.
KEY 7979
REALTA
LED VANDAL-RESISTANT SEALED LUMINAIRES
IP66 LED
IK10++
SPECIFICATION
• Graphite full polyester powder finish. Silver option
• Strong die-cast LM2 aluminium body
• High efficiency prismatic polycarbonate front refractor
• Wide distribution (18W LED) or area distribution
(32W LED) options
• Highly specular, multi-faceted injection moulded
vacuum metallised reflector
• Excellent distribution with less than 2% upward
light component
• Optional photocell control
• Conventionally switched and Smart External versions
• Tamper-resistant pin hex screw fixings
(Requires tool - see Accessory table below)
Wide distribution
Area distribution
• Fitted with 5000K LEDs (18W) and 5700K LEDs (32W)
Realta Design Registration Number 3024955
18W LED CHARACTERISTICS
Ra
°K
65
5000
P/U
%
>85
P
L70/B10
LL/CW
60K
R/Rx
R
61.9
PF
>0.95
RANGE
LED
32W LED CHARACTERISTICS
Ra
°K
65
5700
P/U
%
>88
P
L70/B10
60K
R/Rx
R
PF
>0.95
WIDE
AREAAPPROX.
DISTRIBUTION DISTRIBUTION
kg
CIRCUIT
18W
RL 14436T
3.8L/A
32W
RL 15849T3.9 L/A
LL/CW
73.0
CIRCUIT TYPE - suffix catalogue number with:
L - non-dimming (LED) / A - dimming (DALI) e.g. RL 14436LT etc.
SILVER OPTION - add suffix SV3
For LED characteristics explanation see page 3
e.g. RL 14436LTSV3 etc.
EMERGENCY VERSION - prefix catalogue number with:
ERL - Emergency / TRL - AutoTest / DRL - Scanlight AT e.g. ERL 14436LT etc.
Emergency, AutoTest and Scanlight AT versions add 0.4kg to weights listed
OPTION
DESCRIPTION
SUFFIX
PC
Photocell
Single luminaire pole mounting
attachment - RL 13759
EXAMPLE
RL 14436LTPC
Twin luminaire pole mounting
attachment - RL 14175
DIMENSIONS
Spot marked for
side entry on
both sides.
Customer
to drill if
required.
Photocell
location
18
Photocell
location
220
318
1 x 20 dia.
cable entry
hole (IP66
grommet
supplied)
3 x 6.5 dia. holes
290
266
157
100
All dimensions
in millimetres
262
360
WEB LINKS
thorlux.com/scanlight-at
248
thorlux.com/smart-external
15
ECO-TOUCH : AL
STYLISH DSI/DALI WALL MOUNTED MANUAL
DIMMING CONTROLLER
IK10
A stylish anti-ligature wall-mounted controller
designed to promote convenient and flexible control
of lighting in mental health environments.
ECO-Touch : AL is a sophisticated but simple touch
sensitive controller providing on, off and dimming
control of luminaires fitted with DSI ballasts (Thorlux
product catalogue numbers suffixed T) or DALI
ballasts (suffixed A).
Features
A touch sensitive slider allows the user to dim
luminaires to suit their preferences.
Tamper-resistant pin Torx screw fixings (Supplied
with T10 tool)
RANGE
DESCRIPTION
CAT. No.
APPROX.
kg
ECO 16578
ECO-Touch : AL
Add ‘T‘ suffix to luminaire catalogue number for DSI ballast
or ‘A‘ suffix to luminaire catalogue number for DALI ballast
DIMENSIONS
33
102
ON
112
OFF
3
All dimensions in millimetres
16
www.thorlux.com
0.10
SUITABLE CONTROL GEAR TYPES
ECO-Touch : AL has a DSI/DALI selector switch.
Both types cannot be mixed on the same circuit.
Maximum 25 ballasts.
INSTALLATION NOTES
Standard United Kingdom surface or recessed
single-gang switch box (recommended depth
of 45mm).
Smart Choice
SMART CHOICE FINANCING
With energy savings in excess
of 70% and Smart Choice
Smart Choice
funding, your Thorlux lighting
upgrade really can pay for itself
Smart Choice
Funding for Energy Efficient
Mental Healthcare Lighting
Smart Choice
Smart Choice removes a significant barrier
to wider adoption of energy efficient lighting
in Mental Healthcare establishments by
eliminating the need for an upfront capital
investment. Costs can be spread over an
agreed term allowing for savings in energy
to match or exceed payments.
Key Benefits
Funding provided directly by Thorlux
l
Lighting (No third party involvement)
l No upfront capital payment
l 5 year Thorlux warranty
l No complicated approval process
l Flexible payment profile
Subject to terms and conditions
Four Step Process
How does
it work?
1
Survey of
proposed site
The following four step process is carried out by a Thorlux Lighting
engineer to maximise energy savings and return on investment:
2
3
4
Development of
Calculation of the
Agreement of term
a suitable lighting return on investment
and payment profile
and control scheme
from the scheme
17
Emergency Lighting Systems
The purpose of emergency lighting
is to provide light in the event of a
mains or local power supply failure.
The emergency lighting design must take into account
the following:
Escape route signs
l
Stairs so that each flight receives direct light
l
Changes in level
l
Changes of escape route direction
l
Corridor intersections
l
First aid posts
l
Fire alarm call points or pieces of fire fighting equipment
l
External areas in the immediate vicinity of final exits
l
Moving stairways and walkways
l
Toilet facilities exceeding 8m² or any multiple closet
facility without borrowed light
l
Toilet facilities for disabled use
l
Motor generator, control and plant rooms
l
All other areas as deemed by the Risk Assessment
l
Emergency
Stand-alone Standard Emergency
A range of individually engineered or modified standard luminaires meeting all relevant emergency
luminaire standards but requiring manual testing and maintenance regimes to ensure continued
product integrity.
AutoTest
Stand-alone Emergency
AutoTest emergency luminaires not only meet the basic requirements of standard emergency lighting
products but include the Thorlux AutoTest automatic self-test system. AutoTest products only require visual
inspection as the integral luminaire status LED advises the operational status of the luminaire and the type
of fault, should a fault have occurred.
Scanlight AT
Grouped systems with off-site monitoring capability
The Scanlight AT system offers the benefits of AutoTest but with the added convenience of single point
local small group monitoring of up to 30 luminaires, single point multi-group monitoring of up to 7500
luminaires or single or multi-site web based monitoring. Scanlight AT systems are ideally non-maintained
systems based on the use of recessed LED downlighters and LED exit and ancillary luminaires. This system
is offered in a number of platforms from local user responsibility through to Thorlux monitoring and
maintenance. Truly fit and forget emergency lighting.
18
www.thorlux.com
LED EMERGENCY DOWNLIGHTER : AL
ANTI-LIGATURE LED LUMINAIRES
FOR RECESSED MOUNTING
IP20
DOWNLIGHTER
(BELOW CEILING)
IP20
CONTROL UNIT
IP40
DOWNLIGHTER
(ABOVE CEILING)
LED
SPECIFICATION
l
Small size - unobtrusive
l
Impact resistant and anti-ligature
l
Three hour, non-maintained emergency operation
l
Stand-alone self-test and Scanlight AT compatible
l
May be positioned for maximum effect
l
Reliable LED technology
l
Status indicator shows operational condition
l
Low power consumption (4W total)
l
Superb photometric performance
l
Die-cast heat sink for long LED life
Standard Version - supplied
complete with Control Unit
Die-cast heat sink
DIMENSIONS
RANGE
DISTRIBUTION CAT. No.
40
80
95 dia.
All dimensions in millimetres
APPROX.
kg
TYPE
Area
SLA 172190.9Non-maintained
Standard
SLA 172200.9Non-maintained
Non-AutoTest version on request
37
Luminaires used at Scanlight AT platforms 1 and 2 may self-test
at any time. Consequently, caution should be exercised in
situations where this may be inconvenient. Scanlight AT
platform 3 has inhibit features.
42
207
45
LED DALI Emergency Control
Unit supplied with Scanlight
LED Downlighters
ACCESSORIES
DESCRIPTION
CAT. No.
Mounting bracket for control module ✚
SLA 13101
Mains supply plug (required when not using
modular wiring cables)
SLA 12982
✚
Fits across ceiling T-bars
WEB LINKS
www.thorlux.com
thorlux.com/scanlight-at
19
5 YEAR WARRANTY
Thorlux designs and manufactures its luminaires to the
highest standards, ensuring optimal performance and
reliability. All Thorlux LED and conventional luminaires
delivered after the 1st January 2013 are covered by a 5 year
warranty (excluding lamps and batteries). Customers can
therefore purchase Thorlux luminaires with even
more confidence.
A long and stable history reassures Thorlux customers that
its warranty is meaningful. Many companies offer a pre-sale
warranty, but post-sale claims require that the company
is still trading.
See terms and conditions for full details.
20
www.thorlux.com
WHY BUY FROM THORLUX?
Thorlux, from its technically sophisticated facilities in the UK, designs and
manufactures a comprehensive range of professional lighting and control
systems, including energy-efficient solutions. When choosing Thorlux for
architectural, commercial, floodlighting, industrial, hazardous area or
healthcare applications, you can be confident of receiving:
• Professional, competent advice from a long-established
UK company
•
A choice of lighting and control systems subject to stringent
quality control (BS EN ISO 9001:2008)
•
Excellent customer service and a 5-year warranty
Thorlux, for nearly 80 years, has manufactured increasingly sophisticated
luminaires in the Birmingham area. Over the last 20 years, the company has
focused on high technology products, including the development of its first
electronic energy-saving lighting control system in the mid-1990s. Huge
investment in design and testing facilities in Worcestershire has now put
Thorlux at the forefront of its market sector.
Thorlux Headquarters,
Redditch
Thorlux luminaires are subject to stringent quality control, as demonstrated
by the company’s BS EN ISO 9001:2008 (Quality management systems)
accreditation. Additionally, accreditation of Thorlux to BS EN ISO 14001:2004
(Environmental management systems) gives the customer assurance that
the company manufactures its products in the most environmentally
friendly manner.
MADE IN THE UK
Thorlux Lighting, the largest company in the F.W. Thorpe
Plc group, is proud that around 97% of its products are
manufactured in the UK.
The F.W. Thorpe Plc group employs over 500 people.
In 2013/14, the group paid over £11 million in tax to the
UK government – an amount which supports UK local
authorities and jobs within them.
By manufacturing in the UK, Thorlux can meet urgent
customer demands without the need to transport products
by air to the UK, which would involve additional financial
and environmental costs.
www.thorlux.com
21
LATEST LED
TECHNOLOGY
Thorlux is able to exploit recent advances in LED technology to help meet customer demand
for energy-efficient solutions. The company’s considerable technical expertise and its ability
to invest position it to maximise the opportunities offered by LED technology.
Backed by the group’s modern facilities, Thorlux designers and developers have worked
over recent years to create LED luminaires to meet customers’ operational and aesthetic
requirements. Thorlux has made a huge investment in LED technology, including
in house circuit-board design, software development, thermal modelling and optical
lens design.
To increase the range and performance of its LED luminaires, Thorlux both designs dedicated
LED luminaires from scratch, to optimise optical and thermal performance, and adapts
existing conventional products to offer an LED option.
Unlike a traditional light source, a bare LED is a very intense point-source of light which
has high glare and emits light in one direction only; therefore optical design is very
important. Thorlux takes different approaches to optical design, according to the desired
outcome:
• LEDs, as with lamps, can sit behind a controller or diffuser which will help
to spread the light over a wider area, providing a uniform light
•
Having multiple LEDs on a luminaire provides the option of having individual
optics for each LED
•
Blue light LEDs in combination with a remote phosphor disc and a mixing
chamber made from highly reflective material can maximise efficiency, with
the added benefit of diffusing the light over a wider area, thus reducing glare
from the LED itself
Almost all LED products benefit from bespoke LED printed circuit boards (PCBs) designed
by the Thorlux electronics team. These PCBs ensure that Thorlux luminaires deliver
maximum performance.
In-house LED Printed Circuit
Board Production
22
www.thorlux.com
In-house Goniophotometer
THORLUX
PRODUCT
TESTING
Rigorous product testing is essential in maintaining a reputation
for reliability and quality.
The Thorlux “Lighting Industry Association” registered Photometric
Laboratory enables the company to obtain the best optical performance
from its luminaires. In addition, customers can be sure that photometric
data provided by Thorlux is accurate.
In the photometric test laboratory, a sophisticated goniophotometer
gives fast and reliable measurements of the light distribution from
luminaires. An integrating sphere equipped with spectral analyser
accurately measures light quality, efficiency and colour temperature.
Other in-house testing covers environmental and electrical parameters
including extreme ambient temperatures, dust/water ingress,
electromagnetic compatibility and current harmonics, in accordance
with relevant European standards.
All test equipment is subject to regular in-house maintenance and
calibration, with external third party calibration at regular intervals
to ensure accuracy of data.
www.thorlux.com
23
THORLUX COMPANY
ACCREDITATIONS
THORLUX ISO 9001:2008 CERTIFICATION
THORLUX ISO 14001:2004 CERTIFICATION
ISO 9001:2008 specifies the criteria for a company-wide quality
management system. Using ISO 9001:2008 helps Thorlux ensure that
its customers get consistently good quality products and services.
ISO 14001:2004 sets out the criteria for an effective environmental
management system. Being accredited to ISO 14001:2004 assures
customers that Thorlux measures and reduces its environmental
impacts and complies with environmental legislation.
Thorlux has implemented procedures for designing and developing
products using process control, to ensure consistency of manufacturing.
All manufactured products are subject to full testing procedures
covering both functional and, very importantly, electrical safety.
Records of all production tests as well as all design and development
tests are kept for future reference.
Internal auditing ensures that quality management procedures are
appropriate and maintained. Any issues can be dealt with through
continual improvement. Corrective action is also followed with
preventative action to improve the process and eliminate any chance
of a reoccurrence. Compliance with ISO 9001 is externally audited
by a third party.
HOW TO SPECIFY YOUR
LIGHTING SUPPLIER
24
www.thorlux.com
Compliance with ISO 14001 has put a focus on product design.
Thorlux uses the most efficient materials and components, reducing
the environmental impact through the life of each luminaire.
The manufacturing process is constantly monitored to improve
resource efficiency and reduce waste. Any waste generated, including
end-of-life components, is subject to ethical disposal or recycling.
Thorlux’s UK operation is carbon offset via an independently
endorsed, government approved, company controlled scheme.
1. The supplier shall have ISO 9001 (Quality) independent
assessment and accreditation.
2. The supplier shall be responsible for its environmental
activities and demonstrate genuine concern. This shall
be proven by independent assessment and accreditation
to ISO 14001.
3. The supplier shall provide Certificates of Conformity
demonstrating compliance with European legislation
directives 2006/95/EC, 2004/108/EC and 2011/65/EU.
4. Photometric test information shall be available from
equipment which is independently assessed.
5. The supplier shall offer a commissioning service, provided
by its own trained technicians. A commissioning certificate
shall be provided.
6. All products will be fully tested before despatch to include
safety earth circuit continuity, high voltage electrical
strength testing, full circuit functionality including dimming,
and checks on current drawn.
7. Products and services shall be backed by a comprehensive
5-year warranty – the supplier will have an established
history and track record.
ISO
9001
Quality
Management
FM 10913
ISO
9001
ISO
14001
FM 10913
EMS 532104 EMS 532104
Quality
Management
FM 10913
Environmental
Management
ISO
14001
Environmental
Management
EMS 532104
THORLUX DECLARATIONS OF CONFORMITY
Thorlux products are manufactured to the most stringent quality
control standards in the most environmentally friendly manner.
Declarations of Conformity are available stating that Thorlux luminaires
have been tested to and comply with the relevant international
standards for the manufacture and testing of luminaires and related
products. The standards used are:
EN 55015 Limits and measurement of radio disturbance
EN 61547 Electromagnetic compatibility immunity requirements
Declaration of Conformity
(Directive 2006/95/EC, Directive 2004/108/EC and Directive 2011/65/EU)
ISO
9001
Document Number:
Dated:
Manufacturer:
Address:
Product:
Types:
EN 61000-3-2 Limits for harmonic current emissions
EN 60598-1 Luminaires: general requirements and tests
EN 60598-2-1 Fixed general purpose luminaires
EN 60598-2-22 Luminaires for emergency lighting
Each declaration also confirms that products are manufactured
to an approved ISO 9001 quality system, and that products are fully
tested before despatch. Tests include those for safety earth circuit
continuity, high voltage electrical strength, full circuit functionality
including dimming, and current drawn. Specialist in-house protection
circuitry is employed to prevent damage to equipment under test
conditions.
ISO
14001
Quality
Management
Environmental
Management
FM 10913
EMS 532104
1101
07.10.2015
Thorlux Lighting
Merse Road, North Moons Moat, Redditch, Worcestershire, B98 9HH, UK
Fluorescent Switchstart, Electronic Start, High Frequence and Smart
Kanby, Welby, FG-Line, A-Line, Jubilee, Pendo, Prismalette, Slim Jim,
Radiance, Microdot, Microbloc, Eight-65, Mini-8, Cornice, Exit Sign, Sky-Dome,
Dot, Mercian, Hi-Style, XL-Five, SP-Five, Thoroproof, Glo-Drop, Solow, SolowXL,
Juno, Cleanline, Pitlight, G3, G2, Cobalt, Passlight, Prismalux, Prismatic, CL-Five,
Wall Washer, Glodome, Probe, Tunnel, Flute, Compact 54, Realta,Vandalux,
Thorlux Light Line, Starguard, Notos, Silva, Sortie, Azmet 70, Solow T5,
Solow XLP and Plateau T5
This is to certify that the above product ranges have been designed and manufactured to comply with the EC Directive
2006/95/EC for low voltage equipment, the EC Directive 2004/108/EC for electromagnetic compatibility and the RoHS II
Directive 2011/65/EU restriction of hazardous substances in electrical and electronic equipment.
Polycarbonate and acrylic controllers are UV stabilised. Polycarbonate controllers comply with the 850 degree hot wire test
We declare that the above product range conforms with the standards listed. They are manufactured to an approved
ISO9001 quality system and are 100% tested for safety and operation during production.
Reference
Type
BS EN 55015:2013
EN 61547:2009
BS EN 61000-3-2:2014
BS EN 60598-1:2015
EN 60598-2-1:1989
BS EN 60598-2-22:2014
BS 2782-0:2011
RFI
Immunity
Harmonics
Luminaires: General requirements and tests
Fixed general purpose luminaires
Emergency luminaires
Methods of testing plastic
Name and signature of authorised persons
Ian Mulhall
Technical Director
Mark Laishley
Quality Manager
PN 2438E
The accreditations to ISO 9001 and ISO 14001, coupled with the
in-house testing to BS standards, are clear statements that Thorlux
cares about the quality of its products and about the environment.
TECHNICAL
SUPPORT
The Thorlux Technical Services department
is ready to answer all queries regarding Thorlux
products and the use of these products in specific
environments.
The company also offers a professional on-site
commissioning service to ensure that products
are configured to provide the desired performance
and return on investment. For this service, Thorlux
employs its own fully trained personnel.
www.thorlux.com
25
VNA Fork Lift Trucks
INVESTING FOR
THE FUTURE
Thorlux has recently opened a new 2400m² warehouse
and distribution centre at its headquarters in Redditch, UK.
In line with the company’s environmental policy, the building
has clear roof lights to benefit from natural light, and insulated
cladding to improve thermal efficiency. A steel-fibre-reinforced
super-flat floor ensures that fork lift trucks can operate at full
speed in total safety. Lighting is achieved with the latest Smart
controlled Solow LED luminaires. A passive infrared sensor
detection system, maintained illuminance and daylight
harvesting ensure that a minimum of energy is consumed.
To allow efficient picking of finished goods, two 1.5-tonne
capacity “man-up” very narrow aisle fork lift trucks will raise
the warehouse order pickers to the highest pallet locations to
pick individual luminaires, without the need to bring full pallets
down to floor level. For safety, a personal protection system
automatically stops the fork lift truck if a person or object
is detected nearby.
The new Thorlux warehouse enables core product ranges
to be stocked and made available for speedy delivery using
Thorlux vehicles in the majority of cases.
26
www.thorlux.com
CARBON OFFSETTING
The Thorlux Way
Thorlux is committed to minimising the environmental impact of both
its manufacturing processes and its products. However, even with
the most responsible approach, some carbon dioxide (CO2) will
be released into the atmosphere as an indirect result of factory
and selling activities and customers’ use of luminaires.
In 2009, Thorlux established an ambitious carbon-offsetting scheme
to help compensate for these emissions. The company has chosen
to plant trees. Why trees? Trees and other plants absorb CO2 during
photosynthesis. One tree grown to maturity in open space can
absorb approximately 1 tonne of CO2 over its lifetime. A forest
covering many acres can effectively lock up CO2, creating
a ‘carbon sink’.
The scheme is now accredited under the Woodland Carbon Code.
On its own land in Monmouthshire, Wales, Thorlux has to date
planted over 70,000 trees (Spring 2015).
www.thorlux.com
27
Designers, manufacturers and suppliers
of professional lighting systems
INDUSTRIAL LUMINAIRES
COMMERCIAL LUMINAIRES
FLOODLIGHTING LUMINAIRES
ARCHITECTURAL LUMINAIRES
HEALTHCARE LUMINAIRES
HAZARDOUS AREA LUMINAIRES
CONTROLS AND SYSTEMS
A DIVISION OF F.W. THORPE PLC
Thorlux Carbon Offsetting Project:
www.thorlux.com/trees
The information given in this catalogue is typical and
must not be interpreted as a guarantee of individual
product performance and/or characteristics. We
reserve the right to alter specifications and designs
without prior notice.
Thorlux Lighting
Merse Road
North Moons Moat
Redditch
Worcestershire
B98 9HH
England
+44 (0)1527 583200
+44 (0)1527 584177
[email protected]
www.thorlux.com
Direct UK Sales Line: 01527 583222
T
F
E
W
Thorlux Lighting Ireland
1st Floor, Unit H3
Centrepoint Business Park
Oak Road
Dublin 12
Ireland
T
F
E
W
+353 (0)1 460 4608
+353 (0)1 460 4609
[email protected]
www.thorlux.ie
Thorlux Lighting Deutschland
Ernst Gnoß Strasse 7
40219 Düsseldorf
Deutschland
T
F
E
W
FM 10913
28
P.N. 2591A Oct. 15
EMS 532104
+49 (0)211 695 603-10
+49 (0)211 695 603-11
[email protected]
www.thorlux.de
Thorlux Lighting Australasia Pty Ltd.
18-30 Salisbury Street
Silverwater
Sydney
NSW 2128
Australia
T
F
E
W
+61 (0)2 9648 5611
+61 (0)2 9748 6839
[email protected]
www.thorlux.com.au
Registered Office
15 Industrial Avenue
Wacol QLD 4076
Sales Support All Capitals
Registered No. ACN 139 400 507
Thorlux Lighting LLC
Suite 101
Building No. 425
Sultan Bin Zayed the First Street
PO Box 108168
Abu Dhabi
United Arab Emirates
T
F
E
W
+971 (0)2 656 5842
+971 (0)2 622 4149
[email protected]
www.thorlux.ae