Sweets Armacell 404

Transcription

Sweets Armacell 404
FM
APPROVED
INSULATION PRODUCTS & ACCESSORIES
• AP/Armaflex®
SHEET & ROLL
INSULATION
• AP/Armaflex® SS
• AP/Armaflex®
• AP/Armaflex® W
• AP/Armaflex® SA
TUBE INSULATION
®
• AC/Armaflex® Coil
• AP/Armaflex Duct Liner
• HT/Armaflex®
• ArmaTuff® 25
• NH/Armaflex®
• ArmaTuff® Silver
• Tubolit
• ArmaTuff® White
• Tubolit® SS
• HT/Armaflex®
®
• NH/Armaflex®
ACCESSORIES
• Armafix IPH/NPH Pipe
Hangers
• Armaflex® 520 and 520
BLV Adhesives
• AP/Armaflex® Insulation
Tape
• WB/Armaflex® Finish
PIPE INSULATION
SELF-SEAL PIPE INSULATION
Performance approved
through continuing
supervision by Factory
Mutual Approvals.
FM
APPROVED
PROVEN PERFORMANCE LEADER
DESCRIPTION
AP Armaflex and AP Armaflex SS Self-Seal
Pipe Insulations are 25/50-rated flexible
elastomeric thermal insulations, black in color,
supplied as tubing in popular sizes up to 6"
IPS. (See wall thicknesses, next page.) The
expanded closed-cell structure of AP
Armaflex makes it an efficient insulation. It is
manufactured without the use of CFC’s,
HCFC’s or HFC’s. It is also formaldehyde free,
dust free, fiber free and resists mold and
mildew.
AP Armaflex Pipe Insulation, through 1″ wall
thickness has a flame-spread index of less
than 25 and a smoke-developed index of less
than 50 as tested by ASTM E 84 and
CAN/ULC S-102, “Method of Test for Surface
Burning Characteristics of Building Materials.”
AP Armaflex and AP Armaflex SS are
approved through continuing supervision by
Factory Mutual Approvals and consistently
provide actual values on these key
performance criteria for mechanical system
insulation:
Thermal Conductivity: 0.27 BTU-in/hr. ft2 °F
Water Vapor Permeability: 0.08 perm-inch
Fire Rating: will not contribute significantly
to fire (simulated end use testing)
Factory Mutual Approvals has determined that
AP Armaflex will not contribute significantly to
fire through tests deemed more predictive of
end use performance than ASTM E 84.
Factory Mutual Approvals supervision
includes continuing testing by these methods:
UBC 26-3 Room Fire Test Method and the
Factory Mutual Approvals Full Scale
Horizontal Simulated Pipe Chase Test.
Numerical flammability ratings alone may not
define the performance of products under
actual fire conditions. They are provided only
for use in the selection of products to meet
limits specified.
USES
AP Armaflex Pipe Insulations are used to
retard heat gain and control condensation drip
from cold-water plumbing, chilled-water, and
refrigeration lines. They also efficiently reduce
heat flow for hot-water plumbing and liquidheating and dual-temperature piping. (See
chart next page for recommended
temperature usage range.)
NOTE: Armaflex insulation products must be installed according
to “Installation of Armaflex Insulations.” Proper installation is
required to assure Armaflex insulation performance.
2
For use on cold pipes, AP Armaflex
thicknesses have been calculated to control
condensation on the insulation outer
surface, as shown in the table of thickness
recommendations.
RESISTANCE TO MOISTURE
VAPOR FLOW
The closed-cell structure of AP Armaflex
Insulations effectively retards the flow of
moisture vapor. AP Armaflex is considered a
low-transmittance vapor retarder. AP Armaflex
normally requires no supplemental vaporretarder protection. Additional vapor-retarder
protection may be necessary for AP Armaflex
when installed on very low temperature piping
or where exposed to continually high humidity
conditions.
APPLICATION
AP Armaflex Pipe Insulation in unslit tubular
form can be slipped onto piping before it is
connected, or it can be slit lengthwise and
snapped over piping already connected.
Apply AP Armaflex SS Insulation by placing
the slit tubing over pipe. Peel release liners
from adhesive surfaces and apply firm
pressure along entire longitudinal joint. Secure
butt ends using Armaflex 520 Adhesive or,
where a low V.O.C. adhesive is required,
Armaflex 520 BLV Adhesive.
Fitting covers may be fabricated from
metered-cut AP Armaflex Self-Seal tubing.
Fabricate miter-cut fitting covers and
assemble with Armaflex 520 or 520 BLV
Adhesive. Install over pipe fitting and seal to
adjoining sections of pipe insulation with 520
or 520 BLV Adhesive. 520 Adhesives are
contact adhesives; therefore, in all cases, both
surfaces to be joined are coated with
adhesive.
AP Armaflex is designed for installation above
ground. Indoors, no protective finish is
required. Outdoors, a weather-resistant
protective finish is to be applied. The
recommended protective finish is WB
Armaflex Finish; however, other compatible
finish systems are not ruled out.
SPECIFICATION COMPLIANCE
AP Armaflex developed to meet:
ASTM C 534, Type I — Tubular Grade 1
ASTM E 84
NFPA 225
UL 723
CAN/ULC S102
UL 94 5V-A, V-O, File E 55798
NFPA 90A, 90B
ASTM D 1056, 2B1
MIL-P-15280J — Form T
MIL-C-3133C (MIL STD 670B),Grade SBE 3
CGSB CAN 2-51.40-M80
MEA 96-85-M
City of LA - RR 7642
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
AP ARMAFLEX AND AP ARMAFLEX SS PIPE INSULATION PHYSICAL PROPERTIES
Approved by Factory Mutual Approvals to meet or exceed key property values.
PHYSICAL PROPERTIES
Thermal conductivity,
Btu • in./h • ft2 • °F (W/mk)
75°F (24°C) mean temp
90°F (32°C) mean temp
TEST METHOD
NOTES
0.27 (0.039)
0.276 (0.040)
-13
Water vapor permeability,
perm-in. [Kg/(s • m • Pa)]
0.08 (1.16 x 10 )
ASTM E 96
Procedure A
Flame spread and smoke developed
index through 1" (25mm)
thicknesses
25/50
ASTM E 84
Water absorption, % by volume
0.2
ASTM C 209
Ozone resistance
GOOD
–
Upper use limit (See note 1)
AP Armaflex
AP Armaflex SS
220°F (105˚C)
180˚F (82˚C) (See note 3)
–
Lower use limit (See note 2)
AP Armaflex
AP Armaflex SS
-70°F (-57˚C)* (See note 2)
-70°F (-57˚C)*
–
3/8" , 1/2" , 3/4" , 1" (10, 13, 19, 25 mm)
–
3/8" , ID to 6" IPS (10 mm ID to 168mm)**
6' (1.8 m)
–
–
AP Armaflex Sizes
Wall thickness, inches
(nominal)
Inside diameter, tubular form
Length of sections, feet,
tubular form
AP Armaflex SS Sizes
Wall thickness, inches
(nominal)
Inside diameter, tubular form
Length of sections, feet,
tubular form
1
On the heating cycle, AP Armaflex Pipe
Insulation will withstand temperatures as
high as 220°F (105°C). 520 Adhesive may
be used with pipe insulation applications
up to 220°F (105°C) or, where a low V.O.C.
adhesive is required, use Armaflex 520 BLV
Adhesive.
2
At -20°F (-29°C), flexible AP Armaflex
Insulation becomes hard and, as
temperatures drop below -20°F (29°C),
will be increasingly brittle; however, this
hardening characteristic does not affect
thermal efficiency or water vapor
permeability. For applications of -40°F to
-70°F (-40°C to -57°C), contact Armacell.
3
AP Armaflex SS has a temperature use
limit of -40°F to +220°F (-40°C to 105°C)
for intermittent exposure. For continuous
exposure, the upper use limit is 180°F
(82°C).
ASTM C 177
or C 518
* For applications of -40°F to -70°F
(-40°C to -57°C) contact Armacell
1/2" , 3/4" , 1" (13, 19, 25 mm)
5/8" ID to 4" IPS (15mm ID to 114mm)
6' (1.8 m)
ARMAFLEX PIPE INSULATION THICKNESS RECOMMENDATIONS
Thickness recommendations for controlling outer insulation surface sweating (based upon available manufactured
thicknesses)
PIPE SIZE
LINE TEMPERATURES
50°F (10°C)
35°F (2°C)
0°F (-18°C)
-20°F (-29°C)
Nom
Nom
Nom
Nom
Nom
Nom
Nom
Nom
BASED ON NORMAL DESIGN CONDITIONS*
3/8" ID through 1-1/8" ID (10 mm through 28 mm)
Over 1-1/8" ID through 2-1/8" ID (over 28 mm through 54 mm)
Over 2-1/8" ID through 2 -5/8" ID (over 54 mm through 65 mm)
Over 2 -5/8" ID through 6" IPS (over 65 mm through 168 mm)
Nom
Nom
Nom
Nom
BASED ON MILD DESIGN CONDITIONS**
3/8" ID through 2-5/8" ID (10 mm through 65 mm)
Over 2 -5/8" ID through 6" IPS (over 65 mm through 168 mm)
Nom 3/8" (10 mm)
Nom 1/2" (13 mm)
Nom 3/8" (10 mm)
Nom 1/2" (13 mm)
Nom 1/2" (13 mm)
Nom 1/2" (13 mm)
BASED ON SEVERE DESIGN CONDITIONS***
3/8" ID through 1-5/8" ID (10 mm through 40 mm)
Over 1-5/8" ID through 3-5/8" ID (over 40 mm through 90 mm)
Over 3-5/8" ID through 6" IPS (over 90 mm through 168 mm)
Nom 3/4" (19 mm)
Nom 3/4" (19 mm)
Nom 3/4" (19 mm)
Nom 1" (25 mm)
Nom 1" (25 mm)
Nom 1" (25 mm)
Nom 1-1/2" (38 mm) Nom 1-1/2" (38 mm)
Nom 1-1/2" (38 mm) Nom 1-3/4" (44 mm)
Nom 1-1/2" (38 mm) Nom 2" (50 mm)
3/8"
3/8"
3/8"
1/2"
(10
(10
(10
(13
mm)
mm)
mm)
mm)
Nom
Nom
Nom
Nom
1/2"
1/2"
1/2"
3/4"
(13
(13
(13
(19
mm)
mm)
mm)
mm)
3/4" (19 mm)
1" (25 mm)
1" (25 mm)
1" (25 mm)
1" (25 mm)
1" (25 mm)
1-1/4" (32 mm)
1-1/4" (32 mm)
Nom 3/4" (19 mm)
Nom 3/4" (19 mm)
NOTES
Thicknesses greater than 1" (25 mm) are multiple-layer applications, see technical bulletin #30.
* BASED ON NORMAL DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer
insulation surface sweating indoors under normal design conditions, a maximum severity of 85°F (29°C) and 70% RH. Armacell research and
field experience indicate that indoor conditions anywhere in the United States seldom exceed this degree of severity.
** BASED ON MILD DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer
insulation surface sweating indoors under mild design conditions, a maximum severity of 80°F (27°C) and 50% RH. Typical of these
conditions are most air-conditioned spaces and arid climates.
*** BASED ON SEVERE DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control
outer insulation surface sweating indoors under severe design conditions, a maximum severity of 90°F (32°C) and 80% RH. Typical of these
conditions are indoor areas in which excessive moisture is introduced or in poorly ventilated confined areas where the temperature may be
depressed below ambient.
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
3
TECHNICAL DATA
PHYSICAL PROPERTIES
FAST, CRISP AND CLEAN
FM
APPROVED
DESCRIPTION
AP Armaflex W pipe insulation is a flexible elastomeric thermal
insulation, white in color, supplied as unslit tubing in nominal wall
thicknesses of 1/2″, 3/4″ and 1″ (13 mm, 19 mm and 25 mm). In
popular sizes up to 2-5/8″ ID. The closed cell structure of AP
Armaflex W makes it an efficient insulation with performance
comparable to AP Armaflex. It is manufactured without the use of
CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free,
fiber free and resists mold and mildew.
USES
AP Armaflex W is engineered for residential and commercial air
conditioning and commercial refrigeration applications in which
speed and ease of installation are of primary importance,
especially in open ceiling facilities. AP Armaflex W provides the
thermal efficiency of AP Armaflex pipe insulation, meets all
Armaflex specifications, and reduces the need for priming or
painting.
INSTALLATION
AP Armaflex W slides on the pipe easier, making the installation
job faster, hassle-free, and more profitable for contractors. The
insulation includes a specially formulated lubricating powder that
efficiently reduces friction, plus relaxed I.D. tolerances to
accommodate elbows and fittings. AP Armaflex W installs with
simple hand tools and 520 Adhesive or, where a low V.O.C.
adhesive is required, use Armaflex 520 BLV Adhesives. 520
Adhesives are contact adhesives; therefore, in all cases, both
surfaces to be joined are coated with adhesives.
COIL
LONGER, MORE EFFICIENT
LESS WASTE
4
DESCRIPTION
AC Armaflex Coil is a system designed
for convenience and labor savings with
superior toughness. It is provided in
continuous-length coils, designed to
minimize waste, reduce butt joints, and is
packaged in easy-handle, easy-store cartons.
The pipe insulation is tough but flexible elastomeric
thermal insulation, black in color, supplied as continuouslength unslit tubing in nominal wall thicknesses of 3/8″ (10mm)
and 1/2″ (13mm) in popular sizes up to 1-1/8″ ID. Its closed cell
structure makes it an efficient insulation with the proven
performance of Armaflex. It is manufactured without the use of
CFC’s, HCFC’s or HFC’s. It is also formaldehyde free, dust free, fiber
free and resists mold and mildew.
USES
AC Armaflex Coil is engineered for air conditioning applications in
which speed, ease of installation, convenient handling and on-site
durability are of primary importance. It slides on the pipe easier,
making the installation job faster and more profitable for contractors.
INSTALLATION
AC Armaflex uncoils easily from its convenient carton, so it can be
cut to desired lengths for longer runs with fewer seams. It also
slides on the pipe easier, making the installation job faster and
more profitable for contractors. The specially formulated lubricating
powder effectively reduces friction, and relaxed I.D. tolerances
accommodate elbows and fittings. Its thermal conductivity (0.27),
WVT (0.80), flame spread and smoke developed index (25/50) and
temperature use ranges (-70°F to +220°F) are the same as AP
Armaflex. Installs with simple hand tools and Armaflex 520
Adhesive or, where a low V.O.C. adhesive is required, use
Armaflex 520 BLV Adhesive. 520 Adhesives are contact adhesives;
therefore, in all cases both surfaces to be joined are coated with
adhesive.
TEST METHOD
Thermal conductivity,
Btu • in/h • ft2 °F (W/mk)
75° (24°C) mean temp
0.27 (0.039)
0.276 (0.040)
ASTM C 177
or C 518
Water Vapor permeability,
[kg/(s•m•Pa)]
0.08 [1.16 x 10-13]
ASTM E 96
Procedure A
Water absorption by volume
0.2%
ASTM C 209
Flame spread and smoke
developed index through
1″ (25mm) thickness
25/50
ASTM E 84
Ozone resistance
GOOD
—
Upper use limit
220°F (105˚C)
—
Lower use limit
-70°F (-57°C)*
—
Sizes
Wall thickness (nominal)
1/2″, 3/4″ and 1″ (13, 19 and 25mm)
Inside diameter, tubular form
3/8″ ID to 2-5/8″ ID
Length of sections, tubular form 6′ (1.83m)
Density, typical range
3
3.0 – 6.0 lbs/cu ft
ASTM D 1622
or D 1667
Notes
1
On the heating cycle AP Armaflex W pipe insulation will withstand temperatures as high as 220°F. 520 or 520
BLV Adhesive may be used with pipe insulation applications up to 220°F.
2
At -20°F Flexible AP Armaflex W insulation becomes hard and, as temperatures drop below -20°F, will be
increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor
permeability.
3
For reference only.
* For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell.
TECHNICAL DATA
PHYSICAL PROPERTIES
TEST METHOD
Thermal conductivity,
Btu • in./h • ft2 • °F (W/mk)
75°F mean temp (24°C)
90°F mean temp (32°C)
0.27 (0.039)
0.276 (0.040)
ASTM C 177
or C 518
Water vapor permeability,
perm-in. [Kg/(s•m•Pa)]
0.08 (1.16 x 10-13)
ASTM E 96
Procedure A
Water absorption, by volume
0.2%
ASTM C 209
Flame spread and smoke
developed index through
1″ (25mm) thickness
25/50
ASTM E 84
Ozone resistance
GOOD
—
Upper use limit
220˚F (105°C)
Lower use limit
-70˚F (-57°C)*
Sizes
Wall thickness, (nominal)
Inside diameter, tubular form
Length of sections,
tubular form
3/8″ (10mm), 1/2″ (13mm)
5/8″, 3/4″, 7/8″, 1-1/8″
Density, typical range
3
—
Varies by I.D.
3.0 – 6.0 lbs./ft3
ASTM D 1662
or D 1667
Notes
1
On the heating cycle, AC Armaflex Coil Pipe Insulation will withstand temperatures as high as 220°F (105°C).
520 or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C).
2
At -20°F (-29°C), flexible AC Armaflex Coil Insulation becomes hard and, as temperatures drop below -20°F
(-29°C), will become increasingly brittle; however, this hardening characteristic does not affect thermal
efficiency or water vapor permeability.
3
For reference only.
* For applications of -40°F to -70°F (-40°C to -57°C), contact Armacell.
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
TAKES ON HIGH TEMPERATURES
AND THE ELEMENTS
HT Armaflex is a black flexible
elastomeric thermal insulation
specifically developed to perform
in continuous high temperature
applications up to +300˚F (+150°C).
The formulation of HT Armaflex
provides exceptional ozone and
ultraviolet resistance. A closed-cell material, HT Armaflex
provides low thermal conductivity, good fire behavior, low
temperature flexibility and excellent protection against heat
flow and water vapor diffusion. It is manufactured without
the use of CFC’s, HFC’s HCFC’s. It is also formaldehyde
free, fiber free, dust free and resists mold and mildew.
HT Armaflex is used as insulation and protection for piping
in solar collectors, refrigeration and automotive applications.
The insulation withstands incidental oil contact and performs
on a broad range of metal pipes and tubing in applications.
Supplied in tube and roll form. HT Armaflex is installed in
the same easy manner as AP Armaflex. Armaflex HT625
Adhesive is required to seal the seams and joints
ASTM C 534, Type I (Tubular) Grade 2 and Type ll (Sheet)
Grade 2, UL V-O 5V-A.
HALOGEN-FREE
NH Armaflex is a nonhalogen
flexible elastomeric thermal
insulation, dark grey in color,
supplied as unslit tubing in nominal wall thicknesses of 1/2″
and 3/4″; sheets in thicknesses of 1/2″, 3/4″, and 1″. It was
specially developed by Armacell to eliminate the density of
smoke and reduce corrosive acid gases from combustion.
NH Armaflex will not carry a progressive flame and is
formulated without chlorine, bromines, or PVC.
TECHNICAL DATA
PHYSICAL PROPERTIES
Thermal Conductivity
BTU-in/hr sq.ft °F (W/mK)
32°F mean temperature (0°C)
75°F mean temperature (24°C)
120˚F mean temperature (50˚C)
0.05 [7.25 x 10 -14 ]
ASTM E 96
Procedure A
Water Absorption, % by volume
0.02
ASTM C 209
Ozone Resistance
Excellent
ASTM D 1149
Upper use limit
1
300°F (150°C)
Lower use limit
2
-58°F (-50°C)
Density, tpical range 3, lbs/ft3
3.0 – 6.0
ASTM D 1662 or
ASTM D 1667
Notes
1
Suitable for systems with occasional or intermittent temperatures to 350°F (175°C), with a recommended exposure limit
of one 30-minute period at 350°F (175°C) over 24 hours of operation.
2
At -20 °F (-29 °C) flexible HT/Armaflex insulation becomes hard and as temperatures drop below -20 °F (29 °C), will be
increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability.
3
Reference Only
•
•
•
•
•
•
•
International Maritime Organization (IMO) SOLAS requirements
NH Armaflex is currently specified for use on US Navy vessels
UL-V-0 and HF-1 File Number E55798
ASTM C534 Type 1 (Tubular) Grade 3, Type II (Sheet) Grade 3
ASTM C 795
Nuclear Regulatory Commission Regulatory Guide 1.36
US Coast Guard Requirements (see Armacell for more details)
TECHNICAL DATA
NH Armaflex is used as insulation and protection for piping,
tanks and air ducts, and to prevent stress corrosion with
stainless steel pipes in the following applications: US Navy
applications, general shipbuilding, IMO, nuclear power
plants, other areas where nonhalogenated or chlorine-free
materials may be required.
Supplied in tube, sheet and roll form, NH Armaflex is easy to
snap on or sleeve over pipework. In sheet form, it installs
quickly on large flat or curved surfaces using Armaflex 520
Adhesive or, where a low V.O.C. adhesive is required,
Armaflex 520 BLV Adhesive. 520 Adhesives are contact
adhesives; therefore, in all cases both surfaces to be joined
are coated with adhesives. For pipes and fitting covers, only
seams and joints require adhesive.
• Shipbuilder Electric Boat Corp. EB 4013 Antisweat and
Refrigerant Insulation Systems (Sheets & Tubes).
ASTM C 177
or
ASTM C 518
0.275 (0.039)
0.30 (0.043)
0.32 (0.047)
Water Vapor Permeability
Perm-inch [Kg/s m Pa)]
A closed-cell material, NH Armaflex provides low thermal
conductivity low-temperature flexibility, good fire behavior, and
excellent protection against water vapor diffusion. It is
manufactured without the use of CFC’s, HFC’s or HCFC’s. It
is also formaldehyde free, fiber free, dust free and resists
mold and mildew. When installed in the same manner as
standard AP Armaflex flexible insulation, NH Armaflex
requires no additional vapor retarder under normal conditions.
SPECIFICATION APPROVALS
TEST METHOD
PHYSICAL PROPERTIES
TEST METHOD
Thermal Conductivity,
Btu • in./h • ft2 • °F (W/mK)
32°F mean temperature (0°C)
0.248 (0.036)
75°F mean temperature (24°C) 0.27 (0.039)
104°F mean temperature (40°C) 0.282 (0.041)
ASTM C177
or
ASTM C 518
Water Vapor Permeability
Perm-inch [Kg/(s m Pa)]
0.05 [7.25 x 10-14]
ASTM E 96
Procedure A
Water Absorption, % by volume
0.2
ASTM C 209
Ozone resistance
Excellent
ASTM D 1149
Upper use limit
250°F (120°C)
Lower use limit
-58°F (-50°C)
Toxicity
Free from Halogen/Dioxin/CFC/Mercury/
Carbon Black/Heavy Metal
IMO (International
Maritime Organization)
Combustion gas concentration
Smoke density
Heat release rate
Flame spread
Behavior in Fire
Does not support progressive flaming,
will not melt and drip.
Meets EB 4013 specifications
Meets IMO SOLAS requirements
Density, tpical range 2, lbs/ft3
3.0 – 6.0
Pass
Pass
Pass
Pass
Navy Large Scale
pipe insulation
room/corner test
ASTM D 1662 or
ASTM D 1667
Notes
1
2
At -20 °F (-29 °C) flexible NH/Armaflex insulation becomes hard and as temperatures drop below -20 °F (29 °C), will be
increasingly brittle; however, this hardening characteristic does not affect thermal efficiency or water vapor permeability
Reference Only
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
5
SHEET AND ROLL INSULATION
SELF-ADHERING SHEET AND ROLL INSULATION
Performance approved
through continuing
supervision by Factory
Mutual Approvals.
FM
APPROVED
PROVEN PERFORMANCE LEADER
DESCRIPTION
AP Armaflex and AP Armaflex SA SelfAdhering Sheet and Roll Insulation are flexible,
elastomeric thermal insulations, black in color.
Both are supplied in flat sheets 36″ x 48″ (.92m
x 1.22m), in popular thicknesses. AP Armaflex
and AP Armaflex SA are also available in 48″
(1.22m) continuous rolls in 3/8″, 1/2″, 3/4″, 1″,
1-1/2″ and 2″ (See sizes and metric
conversions, next page). The insulations are
furnished with a smooth skin one side which
forms the outer exposed insulation surface. The
expanded closed-cell structure of Armaflex
makes it an efficient insulation. It is
manufactured without the use of CFC’s,
HCFC’s or HFC’s. It is also formaldehyde free,
dust free, fiber free and resists mold and
mildew.
As tested by ASTM E 84, “Method of Test for
Surface Burning Characteristics of Building
Materials and CAN/UL S-102,” AP Armaflex
Sheet Insulations in thicknesses through 1″
(25mm) have a flame-spread index of less than
25 and a smoke-developed index of less than
50.
AP Armaflex and AP Armaflex SA are approved
through continuing supervision by Factory
Mutual Approvals and consistently provide
actual values on these key performance criteria
for mechanical system insulation.
Thermal Conductivity: 0.27 BTU-in/hr sq.ft. °F
Water Vapor Permeability: 0.08 perm-inch
Fire Rating: Will not contribute significantly to fire.
(simulated end-use testing)
Factory Mutual Approvals has determined that
AP Armaflex will not contribute significantly to
fire through tests deemed more predictive of
the end use performance than ASTM E 84.
Factory Mutual Approvals supervision includes
continuing testing by these methods: UBC 26-3
Room Fire Test Method and the Factory Mutual
Approvals Full-Scale Horizontal Simulated Pipe
Chase Test.
Numerical flammability ratings alone
may not define the performance
of products under actual fire
conditions. They are provided
only for use in the selection of
products to meet limits specified.
USES
AP Armaflex is used to retard heat
gain and control condensation drip from
chilled water and refrigeration systems. It
also efficiently reduces heat flow on hot
systems.
AP Armaflex Sheet/Roll Insulations are
particularly adaptable for insulating ductwork,
large piping and fittings, tanks, and vessels.
Their flexibility allows application to curved
and irregular surfaces. They are very
adaptable to making all types of fitting cover
insulations.
The recommended temperature usage range
for AP Armaflex Sheet Insulation is -70°F to
+220°F (-57°C to +105°C) according to
method of application. AP Armaflex sheet with
6
full adhesive coverage, and AP Armaflex SelfAdhering Sheet, may be used on surfaces with
operating temperatures up to 180°F (82°C).
When used for pipe insulation with adhesive
adhering seams and joints only, Armaflex Sheet
can be applied to lines that will operate to a limit
of 220°F (105°C).
For use on cold surfaces, AP Armaflex
thicknesses have been calculated to control
condensation on the insulation outer surface, as
shown in the table of thickness
recommendations.
RESISTANCE TO MOISTURE
VAPOR FLOW
The closed-cell structure of Armaflex Insulations
effectively retards the flow of moisture vapor,
and Armaflex is considered a low-transmittance
vapor retarder. For many applications, Armaflex
needs no supplementary protection.
Additional vapor-retarder protection may be
necessary for Armaflex when install on very lowtemperature surfaces or piping or where
exposed to continually high humidity conditions.
APPLICATION
AP Armaflex Sheet is installed using Armaflex
520 Adhesive or, where a low V.O.C. adhesive is
required, use Armaflex 520 BLV Adhesive. For
application to large flat or curved metal surfaces
such as ducts, very large pipes, tanks, and
vessels, full adhesive coverage is used. For
applications as pipe insulation and fitting covers,
only the seams and joints are adhered with
adhesive. 520 Adhesives are contact adhesives;
therefore, in all cases, both surfaces to be joined
are coated with adhesive.
AP Armaflex Self-Adhering Sheet has a factoryapplied adhesive system with long-term
performance similar to 520 Adhesive. It can be
applied to clean, non-oily metal surfaces. Simply
remove a portion of the release liner, position
sheet, adhere one edge, and then just peel and
press. Seams and joints are adhered using 520
or 520 BLV Adhesive.
AP Armaflex Sheet and Self-Adhering Sheet
insulations are designed for installation above
ground. Indoors, no protective finish is required.
Outdoor, a weather-resistant protective finish is
to be applied. The recommended protective
finish is WB Armaflex; however, other compatible
finish systems are not ruled out.
SPECIFICATION COMPLIANCE
AP Armaflex developed to meet:
ASTM C 534, Type II -- Sheet, Grade 1
ASTM C 1534
ASTM E 84
NFPA 255
UL 723
CAN/ULC-S102
UL 94 5V-A, V-0, File E 55798
NFPA 90A, 90B
ASTM D 1056, 2B1
MIL-P-15280J, FORM S
MIL-C-3133C (MIL STD 670B), Grade SBE 3
MEA 107-89-M
City of Los Angeles -- RR 7642
CGSB CAN 2-51.40-M80
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
AP ARMAFLEX SHEET AND ROLL AND SELF-ADHERING SHEET AND ROLL
INSULATION AVERAGE PHYSICAL PROPERTIES
Approved by Factory Mutual Approvals to meet or exceed key property values
PHYSICAL PROPERTIES
Thermal conductivity,
Btu • in./h • ft2 • °F (W/mK)
75°F mean temp (24°C)
90°F mean temp (32°C)
TEST METHOD
0.27 (0.039)
0.276 (0.040)
ASTM C 177
or C 518
Water vapor permeability,
perm-in. [Kg/(s•m•Pa)]
0.08 (1.16 x 10-13)
ASTM E 96
Procedure A
Water absorption, % by volume
0.2%
ASTM C 209
Flame spread and smoke
developed index through
1″ (25mm)
25/50
ASTM E 84
Ozone resistance
GOOD
—
Upper use limit
(See note 1)
220˚F (105˚C) AP Armaflex
180˚F (82°C) AP Armaflex SA (See note 3)
—
Lower use limit
(See note 2)
-70˚F (-57°C)*
—
Sizes – Sheet
Width and length
Thickness (nominal)
Sizes – Roll
Thickness (nominal) x Length
Notes
1
When AP Armaflex Sheet is installed by adhering butt
joints and seams only, the upper temperature limit is
220°F (105°C) using 520 or 520 BLV Adhesive. AP
Armaflex Sheet adhered with complete adhesive
coverage on flat or curved metal surfaces may be
applied to surfaces that will operate as high as 180°F
(82°C) using 520 or 520 BLV Adhesive.
2
At -20°F (-29°C), flexible AP Armaflex Insulation
becomes hard and, as temperatures drop below -20°F
(-29°C), will be increasingly brittle; however, this
hardening characteristic does not affect thermal
efficiency and resistance to water vapor permeability.
For applications of -40°F to -70°F (-40°C to -57°C),
contact Armacell.
3
AP Armaflex SA has an upper temperature use limit of
+180°F (+82°C)
* For applications of -40°F to -70°F
(-40°C to -57°C), contact Armacell.
36″ x 48″ (.92m x1.22m)
1/8″, 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/2″ & 2″
(3, 6, 10, 13, 19, 25, 38 & 50mm)
—
3/8″ x 100′ (10mm x 30.5m)
1/2″ x 70′ (13mm x 21.4m)
3/4″ x 50′ (19mm x 15.2m)
1″ x 35′ (25mm x 10.7m)
1-1/2″ x 25′ (38mm x 7.6m)
2″ x 18′ (50mm x 5.4m)
—
AP ARMAFLEX SHEET AND ROLL AND SELF-ADHERING SHEET AND ROLL
INSULATION THICKNESS RECOMMENDATIONS
THICKNESS RECOMMENDATIONS FOR CONTROLLING OUTER
INSULATION SURFACE SWEATING
DUCTS–TANKS–VESSELS–EQUIPMENT
METAL-SURFACE TEMPERATURE
50°F (10°C)
35°F (2°C)
0°F (–18°C)
BASED ON NORMAL DESIGN CONDITIONS
AP Armaflex in the thicknesses noted and within the specified
temperature ranges will control outer insulation surface condensation
indoors under normal design conditions, a maximum severity of
85°F (29°C) and 70% RH. Armacell research and field experience
indicate that indoor conditions anywhere in the United States seldom
exceed this degree of severity.
Nom 3/8″ (10mm)
Nom 3/4″ (19mm)
Nom 1-1/2″ (38mm)
BASED ON MILD DESIGN CONDITIONS
AP Armaflex in the thicknesses noted and within the specified
temperature ranges will control outer insulation surface condensation
indoors under mild design conditions, a maximum severity of 80°F
(27°C) and 50% RH. Typical of these conditions are most airconditioned spaces and arid climates.
Nom 1/8″ (3mm)
Nom 1/4″ (6mm)
Nom 1/2″ (13mm)
BASED ON SEVERE DESIGN CONDITIONS
AP Armaflex in the thicknesses noted and within the specified
temperature ranges will control outer insulation surface condensation
indoors under severe design conditions, a maximum severity of 90°F
(32°C) and 80% RH. Typical of these conditions are indoor areas in
which excessive moisture is introduced or in poorly ventilated confined
areas where the temperature may be depressed below ambient.
Nom 1″ (25mm)
Nom 1-1/2″ (38mm)
Nom 2″ (50mm)
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
7
DUCT LINER
HELPS PREVENT
MOLD & MILDEW
PATENTED
MEETS NFPA 90A AND 90B
HOSPITAL GRADE
DESCRIPTION
AP Armaflex SA is a black flexible elastomeric thermal insulation with a self-adhering backing. It
is a closed-cell elastomeric foam that can reduce or eliminate conditions amplifying biological
contamination and bioaerosols in commercial air systems.
Engineered to control condensation, AP Armaflex SA has an inherent vapor retarder and
requires no additional mastics or coatings. It is nonwicking and has a very low rate of water
absorption. It continues to prevent water infiltration even after incidental mechanical abuse.
The surface of the insulation is smooth, so that dirt and debris that may enter the air stream tend
not to accumulate. The surface is durable and erosion-resistant. AP Armaflex SA is also cleanable
and washable, providing a basis for continuing system hygiene. With its self-adhering backing,
AP Armaflex SA is fast and easy to install and requires no mechanical fasteners in systems
operating at 4,000 FPM (20.3 m/second) or below. The expanded closed-cell structure of
Armaflex makes it an efficient insulation. It is mnufactured without the use of CFC’s, HCFC’s. It
is also formaldehyde free, fiber free, dust free and resists mold and mildew.
AP Armaflex SA Duct Liner is supplied in self-adhering sheets 36″ x 48″ (.915 m x 1.22 m), in
nominal wall thicknesses of 3/8″, 1/2″, 3/4″ and 1″ (10, 13, 19 and 25 mm). Acoustical
performance is comparable to half-inch thick fiberglass insulation. The product is approved
through continuing supervision by Factory Mutual Approvals.
USES
AP Armaflex SA Duct Liner is a suitable replacement for traditional duct liner in air handlers,
VAV units, ducts, and other air system components requiring condensation control and moisture
and damage resistance. It meets the requirements of NFPA 90A, NFPA 90B for Duct Coverings
and Linings and UL 181.
TECHNICAL DATA
PHYSICAL PROPERTIES
TEST METHOD
Thermal Conductivity
BTU-in/hr • sq.ft • °F (W/mK)
75°F mean temperature (24°C)
90°F mean temperature (32°C)
0.27 (0.039)
0.276 (0.040)
ASTM C 177 or C 518
Water Vapor Permeability
Perm-inch [Kg/(s m Pa)]
0.08 [1.16 x 10-13]
ASTM E 96 Procedure A
Water Absorption, % by volume
0.2
ASTM C 209
Flame spread and Smoke
developed index 1 Through1″ (25 mm)
25/50
ASTM E 84
CAN ULC S-102
ALCOHOL
The temperature of the air Prepare surface by cleaning
and of the insulation should with appropriate cleaner.
be between 40°F (4°C) and Measure.
100°F (38°C) at the time of
installation. Surface to be
covered must be clean and
free of any loose materials
such as rust.
Cut with sharp knife.
Upper Use Temperature Limit,
2
180°F (82°C)
Lower Use Temperature Limit,
3
-58°F (-50°C)
Microbial Growth
No Growth
Erosion Resistance
Does not break away,
flake off or show
ASTM C 1071
evidence of
delamination at
velocities of 6,000 ft/min
Corrosiveness
Noncorrosive
Peel back enough release
liner to start.
Odor Emissions
Reach behind the Armaflex
sheet and peel liner back
while pressing the sheet to
the surface. Remove the
entire liner piece.
ASTM C 665
No objectionable odors ASTM C 665
Density, typical range, lbs/ft
Square off sheet along an
edge or corner. Press the
sheet to the surface taking
care not to trap any air.
ASTM G 21 (Fungal),
ASTM G 22 (Bacterial)
ASTM C 1338
4
3.0 -- 6.0
ASTM D 1662 or
ASTM D 1667
Notes
1
AP/Armaflex SA Duct Liner
has a flame spread index of
less than 25 and a smoke
developed index of less than
50 for all thicknesses up to
and including 1″ (25mm) when
tested according to ASTM E
84 and CAN ULC S-102.
Numerical flammability ratings
alone may not define the
performance of products under
actual fire conditions. They
are provided only for use in the
selection of products to meet
limits specified.
2
Withstands temperature of
250°F (121°C) when tested
according to ASTM C 411.
"Test Method for Surface
Performance of HighTemperature Insulations". At
this temperature, AP/Armaflex
SA Duct Liner insulation
shows no evidence of flaming,
glowing, smoldering,
delamination, melting or
insulation collapse. Although
this insulation will withstand
high temperatures, continuous
use temperature should be
limited to 180°F (82°C)
3
At -20°F (-29°C) flexible
Armaflex insulation becomes
hard and as temperatures drop
below -20°F (-29°C), will be
increasingly brittle; however,
this hardening characteristic
does not affect thermal
efficiency or water vapor
permeability.
4
Reference Only
Sound Absorption Coefficients at Frequency
Thickness
125Hz
250Hz
500Hz
1000Hz
2000Hz
4000Hz
NRC†
3/4″ (19mm)
0.04
0.07
0.16
0.69
0.18
0.25
0.30
1″ (25 mm)
0.00
0.08
0.32
0.55
0.23
0.21
0.30
†
ASTM C 423 with ASTM E 795 Type “A” Mounting
Sound Transmission Class (STC)
1/4"
Press firmly. Butt joints
require the use of
compression joints to
prevent the possible
opening of seams.
Thickness
STC Class
1/2″ (13 mm)
25
1″ (25 mm)
25
Test Method ASTM E90
8
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
Products
LAMINATED
SHEET & ROLLS
ArmaTuff 25
• The best choice for exceptional durability. The white laminate is a rugged thermoplastic
rubber (TPR) membrane with a 25-year warranty against degradation due to ultraviolet
radiation. With Armatuff 25, maintenance is practically eliminated, so the lifestyle costs are
substantially reduced. The product also provides superior resistance to acid rain and
chemicals.
ArmaTuff White
• Offers great durability and UV resistance, at a lower cost. The laminate is a foil and polymer
composite, with an extra coating for resistance to both acid rain and chemicals.
ArmaTuff 25
Maximum
Durability
ArmaTuff Sliver
• The most economical option. Although there are other foil-faced insulations available,
ArmaTuff Silver is the only one with genuine Armaflex.
ArmaTuff is installed using Armaflex 520 or, where a low V.O.C. adhesive is required, use
Armaflex 520 BLV Adhesive. Adhesives or with pre-applied pressure sensitive adhesive (PSA)
for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or
tanks. The seams must be installed in compression and sealed with Armaflex 520 Adhesives.
Cover the seam with Armatuff Seal Tape.
ArmaTuff White
Excellent
Performance
ArmaTuff
Seal Tape
Sizes
Sheets
Continuous Rolls
ArmaTuff 25
36″ x 48″ (0.915 x 1.22m)
1″, 1-1/2″ and 2″ thickness
with PSA only
48″ wide (1.22m)
2″, 4″, 6″
1″, 1-1/2″ and 2″ thickness
without PSA only
ArmaTuff Silver,
ArmaTuff White
36″ x 48″ (0.915 x 1.22m)*
1/2″, 3/4″, 1″, 1-1/2″ and
2″ thickness
48″ wide (1.22m)*
1″, 1-1/2″ and
2″ thickness
ArmaTuff Silver
Economical
2″, 4″, 6″
and 23-1/2″
* With or without PSA
PHYSICAL DATA
PHYSICAL PROPERTIES
TEST METHOD
Thermal Conductivity,
Btu-in-hr-ft•F (W/mK)
75°F mean temperature (24°C)
90°F mean temperature (32°C)
0.27 (0.039)
0.276 (0.040)
ASTM C 177 or C 518
Water Vapor Permeability,
perm-inch [kg/(s m Pa)]
0.02 [2.9 x 10-14]
ASTM E 96 Procedure A
Water Absorption % by volume
0.2
ASTM C 209
Upper Use Temperature Limit
180°F (82°C)
Lower Use Temperature Limit
-70°F (-57°C)
UltraViolet (UV) Resistance
Excellent
Chemical Resistance
ArmaTuff 25, ArmaTuff White
ArmaTuff Silver
Excellent
Good
Weatherability
ArmaTuff 25, ArmaTuff White
ArmaTuff Silver
Excellent
Good
Durability
ArmaTuff 25
ArmaTuff Silver, ArmaTuff White
Excellent
Good
Microbial Growth
No Growth
ASTM G 21 (Fungal)
ASTM G 22 (Bacterial)
3.0 - 6.0
ASTM D 1622 or
ASTM D 1667
Density, typical range 3 ,lbs/ft
3
Installation
1. Always prepare surface
by cleaning with
denatured alcohol.
2. Insulate sides first. Apply
thin, uniform coat of
Armaflex 520 or 520 BLV
Adhesive.
3. Roll thin coat of 520 or
520 BLV Adhesive to
insulation.
4. Position carefully and
apply ArmaTuff. Contact
adhesive bonds instantly.
5. Apply ArmaTuff to top
surface, overlapping the
side pieces.
6. Seal and protect exposed
edges and seams with
ArmaTuff Seal Tape.
QUV Chamber
ASTM D 471
1
At -20°F (-29°C) flexible Armaflex insulation becomes hard and, as temperatures drop below -20°F (-29°C), will be increasingly brittle; however, this
hardening characteristic does not affect thermal efficiency or water vapor permeability.
2
For reference only.
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
9
PIPE INSULATION AND
PIPE INSULATION
QUICK &
COST EFFECTIVE
DESCRIPTION
Tubolit and Tubolit Self-Seal Pipe Insulations
are 25/50-rated flexible closed-cell black
polyolefin/polyethylene pipe insulations,
supplied as semi-slit or self-seal, in nominal
wall thicknesses of 3/8″, 1/2″, 3/4″, and 1″
(10, 13, 19 and 25 mm), in the most
frequently specified sizes. Tubolit is
expanded without the use of CFC’s, HCF’s
or HCFCs. It is also formaldehyde free, dust
free, fiber free and resists mold and mildew.
USES
Tubolit Pipe Insulations are particularly
effective for cost-efficient thermal insulation
of domestic heating and plumbing lines. The
recommended temperature usage range for
Tubolit Insulations 0°F to +180°F (–17°C to +
82°C).
As tested by ASTM E 84, “Method of Test
for Surface Burning Characteristics of
Building Materials,” Tubolit insulations
through 1″ wall have a flame-spread index of
less than 25 and a smoke-developed index
of less than 50.
Tubolit Self-Seal Insulation is snapped over
new or existing pipework.
Both install with simple hand tools and
Armaflex 520 Adhesive or, where a low
V.O.C. adhesive is required, Armaflex 520
BLV Adhesive. Butt joints should be sealed
with either 520 or 520 BLV Adhesive. 520
Adhesives are contact adhesives; therefore,
in all cases, both surfaces to be joined are
coated with adhesive. Seams can be sealed
with 520 or 520 BLV Adhesive.
Tubolit and Tubolit SS must be protected
from direct sunlight exposure and weather
elements and must be protected when
installed outdoors with weather-resistant
jacketing or WB Armaflex Finish.
SPECIFICATION COMPLIANCE
ASTM C1427-Tubolit
MEA 6-02M
APPLICATIONS
Tubolit Pipe Insulation in tubular form
is easy to sleeve over new
pipework, or cut longitudinally to
snap over existing pipework.
TECHNICAL DATA
AVERAGE PHYSICAL PROPERTIES (See Note 1)
Thermal conductivity,
Btu • in/h • ft2 °F (W/mK)
75° (24°C) mean temp
TEST METHOD
0.25 (0.036)
ASTM C 177
or C 518
Water vapor transmission,
perm-in [kg/(s•m•Pa)]
0.02 (2.9 x 10-14)
ASTM E 96
Procedure A
Flame spread and smoke
developed index through 1″
thicknesses (see note 2)
25/50
ASTM E 84
Density, lbs/ft3 (Kg/m3)
2 (32)
ASTM D 1622
3
Ozone resistance
GOOD
Upper use limit
Tubolit 200°F (93°C)
Tubolit SS 180°F (82°C)
Lower use limit
-200 of (-129°C)
Sizes
Wall thickness (nominal)
Inside diameter, tubular form
Length of sections, tubular form
3/8″, 1/2″, 3/4″ and 1″ (10, 13, 19, 25 mm)
3/8″ ID to 4″ IPS (10 mm ID to 114 mm)
6′ (1.83 m)
NOTES
1
Average values are not to be used for writing material specifications. Contact Armacell for specification ranges.
10
2
See Armacell Info-Services #008 and #022, and “Fire Performance: Differences Between Elastomeric and Polyethylene
Insulations.”
See Armacell Info-Service #010 for details.
3
For reference only.
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
INSULATION PIPE HANGERS
DESCRIPTION
Armafix Insulation Pipe Hangers are quick,
innovative alternatives to traditional block
and dowel pipe supports. The engineered,
foam-to-foam solutions provide optimum
load bearing while protecting against
thickness compression and condensation
gaps that can compromise system integrity.
USES
Armafix is used to support insulated pipes
with pre-insulated hangers that retard heat
gain and control condensation drip from
cold-water plumbing, chilled-water and
refrigeration lines. It is engineered from
Armaflex or NH/Armaflex insulation, with
polyurethane inserts 30mils thick and
aluminum (IPH) or stainless steel (NPH)
jacket. It is single-piece construction, selfadhesive closure with exclusive foam-tofoam bond. Armafix (IPH) pipe hangers are
available in nominal 3/4″ and 1″ wall
thicknesses with ID’s ranging from 3/8″ ID to
8″ IPS. Also available in nominal 1/2″ wall
thickness by special order. Armaflex NPH:
NH/Armaflex nonhalogen insulation
formulation available in 3/4″ nominal wall
thickness with ID’s ranging from 3/8″ ID to 8″
IPS. Armaflex insulation’s thermal
conductivity resistance to moisture vapor
flow (WVT) and closed cell structure provide
for total system integrity.
EFFICIENT,
FASTER SUPPORT
APPLICATION
Armafix longitudinal seams are selfadhering. The ends are easily sealed with
Armaflex 520 Adhesive or, where a low
V.O.C. adhesive is required, Armaflex 520
BLV Adhesive to ensure a completely sealed
system. For some applications, saddles are
recommended. To minimize the movement of
Armafix, it is recommended that a pair of
non-skid pads, be adhered to the clamps. In
addition to prevent loosening of the clamps,
use of an anti-vibratory fastener, such as a
nylon looking nut, is also recommended.
Painted aluminum or stainless steel jacket
Armaflex
Supports
made
of CFC-free
PUR/PIP
Selfclosure
Painted aluminum or stainless steel jacket
TECHNICAL DATA
PHYSICAL PROPERTIES
TEST METHOD
Thermal Conductivity
BTU-in/hr • sq.ft. • °F (W/mK)
75°F mean temperature (24 °C)
90°F mean temperature (32 °C)
0.27 (0.039)
0.276 (0.040)
Water Vapor Permeability
Perm-inch [Kg/(s m Pa)]
(IPH) 0.08 [1.16 x 10-13]
(NPH) 0.05 [7.25 x 10-14]
ASTM E 96 Procedure A
Water Absorption, % by volume
0.2
ASTM C 209
Upper Use Temperature Limit
220 °F (105 °C)
Lower Use Temperature Limit
1
Density, typical range 2 , lbs/ft3
ASTM C 177 or C 518
-58 °F (-50 °C)
8.0 -- 11.0
ASTM D 1662 or
ASTM D 1667
Notes
1
At -20 °F (-29 °C) flexible Armaflex insulation becomes hard and as temperatures drop below -20 °F
(-29 °C), will be increasingly brittle; however, this hardening characteristic does not affect thermal
efficiency or water vapor permeability.
2
Reference only.
Easy Application on Clevis (saddle)
Application with insulation
Clamp (Friction fit)
FOR MORE INFORMATION, CALL 919-304-3846, FAX 919-304-3847 OR EMAIL: [email protected]. Website: www.armacell.com
11
Insulation Products for Mechanical Systems
520 & 520 BLV ADHESIVES
FINISH
INSULATION TAPE
Armaflex® 520 Adhesive is an air-drying
contact adhesive that is excellent for joining
seams and butt joints of AP and NH
Armaflex Pipe and Sheet Insulation and
Tubolit Pipe Insulation or, where a low V.O.C.
adhesive is required, use Armaflex 520 BLV
Adhesive.
WB/Armaflex Finish is a white water-based
latex enamel for use over all forms of
Armaflex Insulations. It provides a protective
semi-gloss finish for both indoor and outdoor
applications. WB Armaflex Finish brushes or
rolls on easily. Its water base formulation
makes it fast-drying without solvent fumes.
Cleans up with soap and warm water. WB
Armaflex Finish is supplied in gallon and
quart containers.
AP/Armaflex Insulation Tape is made of the
same high-quality elastomeric thermal
insulation material as AP Armaflex
Insulation. The tape is supplied in
convenient strip form, 2″ (50 mm) wide, 30′
(9.1 m) long and 1/8″ (3 mm) thick. AP
Armaflex Insulation Tape provides a fast,
easy method for insulating pipes and fittings.
It is used to control condensation drip on
domestic cold-water, chilled water, and other
cold piping and fittings and to reduce heat
loss when applied to hot-water lines that will
operate up to 180°F (82°C).
520 Adhesive meets Military Specification
MIL-A-24179A and Amend-2 as Type II,
Class 1. Both 520 Adhesives when dried to a
film meet flammability classification
requirements of codes and specifications of
less than 25 for flame spread index and less
than 50 for smoke developed index when
tested by ASTM E 84 Test Method.
ARMACELL LLC
7600 Oakwood Street Extension
P. O. Box 1038
Mebane, NC 27302
WB Armaflex Finish adheres to clean
Armaflex surfaces and dries to a pliant
coating. Up to 400 square feet (37 square
meters) per gallon coverage per single brush
coat depending on temperature and location.
Indoors, it provides a clean white protective
finish, which is impervious to moisture.
Outdoors, its special properties make it
exceptionally durable and weather resistant
to ultraviolet (UV) and ozone. Like typical
paint coatings, WB Armaflex finish requires
routine maintenance Outdoor surfaces
should be recoated every 2-4 years.
Meets Flammability classification
requirements of codes and specifications of
less than 25 for flame spread index and less
than 50 for smoke developed index when
tested by ASTM E 84 test method.
Armacell provides all information contained in this catalog as a technical service. To the extent the information is
derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to
provide accurate information. Information provided as a result of Armacell’s own technical analysis and testing is
accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and
procedures. Each user of these products, or information, should perform their own tests to determine the safety,
fitness and suitability of the products or combination of products, for any foreseeable purposes, applications and
uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control
the end use of these products, Armacell does not guarantee that the user will obtain the same results as published in
this document.The data and information are provided as a technical service and are subject to change without notice.
TEL. 919 304-3846
FAX 919 304-3847
E-MAIL [email protected]
INTERNET www.armacell.com
999S 001S
05
04
NA
NA
© 2004 Armacell LLC
Printed in United States of America