www.LEUTRON.DE
www.LEUTRON.DE Lightning and surge protection We reserve the right to make alterations in style and form in line with technical development. The illustrations are non-binding. We do not assume liability for mistakes or printing errors. All orders will only be accepted in General Terms and Conditions of Sale of the Company of Leutron GmbH. © Leutron GmbH, 1st. Edition 04/2012. P/N 98 01 44 Contents overview n Surge protection for power supply systems.. . . . . . . . . . . . . 2 Crossreferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SPD type 2 for AC power supplies (leakage-current free). . . . . . . . . . . SPD type 3 for AC power supplies. . . . . . . . . . . . . . . . . . . . . . . . . . Selection guide.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 AC power supply.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DC power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lightning current arrester type 1 for DC power supplies. . . . . . . . . . . . Lightning current arrester type 1 for AC power supplies.. . . . . . . . . . . 11 Combined arrester type 1 + 2 for AC power supplies. . . . . . . . . . . . . 19 SPD type 2 for DC power supplies. . . . . . . . . . . . . . . . . . . . . . . . . . SPD type 2 for AC power supplies. . . . . . . . . . . . . . . . . . . . . . . . . 27Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 49 58 60 62 65 n Surge protection for measuring systems and automatic control devices . . . . 68 Crossreferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Pluggable SPD for high frequency MCR applications. . . . . . . . . . . . . . 97 One-piece SPD for MCR applications. . . . . . . . . . . . . . . . . . . . . . . 100 Selection guide.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Pluggable SPD for MCR applications. . . . . . . . . . . . . . . . . . . . . . . . 79 One-piece SPD with high discharge cappability for MCR applications. . 101 One-piece SPD with high discharge cappability and low protection level Pluggable SPD with high discharge cappability for MCR applications. . . 79 Pluggable SPD with high discharge cappability and low protection level for MCR applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 for MCR applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 One-piece SPD with low protection level for MCR applications. . . . . . . 113 n Surge protection for information technology and telecommunication installations. . . . . . . . . . . . . . . . . . . . SPD for communication networks. . . . . . . . . . . . . . . . . . . . . . . . . SPD for telecommunication networks. . . . . . . . . . . . . . . . . . . . . . Surge protective devices for LSA mounting.. . . . . . . . . . . . . . . . . . 120 124 130 133 n Surge protection for transmitting and receiving systems.. SPD for SAT/TV/Radio applications. . . . . . . . . . . . . . . . . . . . . . . . SPD with BNC connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPD with SMA connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPD with N connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 158 159 161 162 SPD according to test category D1+C2.. . . . . . . . . . . . . . . . . . . . . 135 SPD according to test category C2+C1.. . . . . . . . . . . . . . . . . . . . . 138 Lambda/4 stubline SPD with N connector. . . . . . . . . . . . . . . . . . . . SPD with DIN 7/16 connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . Lambda/4 stubline SPD with DIN 7/16 connector. . . . . . . . . . . . . . . SPD with FME connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 165 167 170 n EMC filter with integrated surge protection. . . . . . . . . . . . 172 Line filter up to 200 A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 MCR technology with integrated low-pass filter. . . . . . . . . . . . . . . . 181 n Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Universal function tester for GDT, MOV and diodes, mixed circuits. . . . Function tester for GDT and GDT based spark-gaps. . . . . . . . . . . . . Function tester for MOV and overvoltage protection diodes.. . . . . . . . 192 196 197 198 Portable test equipment for GDT in LSA magazines.. . . . . . . . . . . . . 199 Pulse counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 n Rare-gas-filled insulation spark gaps. . . . . . . . . . . . . . . . 202 Flexible mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 ATEX-certificated for explosion hazardous zones EX. . . . . . . . . . . . . 211 DIN rail mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 n Protective devices for AC arresting. . . . . . . . . . . . . . . . . . 214 AC-current diverter up to AC 80 A with lightning protection. . . . . . . . 218 Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 Numeric product register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 Dimension drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220Alphabetical product register. . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 Technical terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 General Terms and Conditions of Sale. . . . . . . . . . . . . . . . . . . . . . 234 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection with a new design The multi-pole combined modular arresters for protection against lightning strikes and transient surge voltages now have an even more attractive design. In addition to their outstanding technical properties, they are pluggable and provide a clearly readable function control indication and status display. The variable installation position – the base part can be plugged in two directions – enables a flexible and cost-saving wiring. Easy setup, secure operation: 2 nNew: Easy changing of the protection module thanks to a twopart design with a vibration-resistant locking nRemote signalling using only one signalling contact – even with 4-pole devices nRobust and maintenance-free due to the hermetically closed rare-gas-filled isolating spark gap without internal or external trigger electronics Surge Protection for Power Supply Systems The new design developed together with product design specialists allows for an easier handling. Surge Protection for Power Supply Systems Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 3 Two-piece pluggable surge protective devices for AC power supply systems New product line »Leutron Power«: Powerful and standardized pluggable modules for almost every power supply system available. nOptimized follow-on current extinguishing capability Mechanical status indicator: State of the surge protective device is optically indicated Locking function: Release of the latches by ergonomically shaped grip lugs Protection against mismating: Optimized installation due to arresters with coding Remote signalling: Combined remote contact (changeover contact) optionally available Turnable plug-in modules: The plug-in modules can be twisted on the basic module, thus, guaranteeing always good readability even with variable wiring 4 Surge Protection for Power Supply Systems Two-piece pluggable surge protective devices for DC power supply systems Mechanical function indicator: State of the surge protective device is indicated optically Arrester elements available for 600 V and 1,000 V applications Safety for photovoltaic installations: Disconnection function in case of overloads optimized for photovoltaic installations Remote signalling: Combined remote contact (changeover contact) optionally available Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 5 Cross reference list to select the appropriate products This cross reference helps to find the new, appropriate products on the basis of the previous product names. Previous product nameNew product name 6 37 39 12 PP B TT 50/100/FM 96 02 07 CT-T1/3+1-350-FM 37 39 22 PP BC TT 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 37 39 32 PP BCD TT 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 37 39 42 PP B TNS 50/100/FM 96 02 07 CT-T1/3+1-350-FM 37 39 52 PP BC TNS 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 37 39 62 PP BCD TNS 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 37 39 72 PP B TNC 50/100/FM 96 02 09 CT-T1/3+0-350-FM 37 39 82 PP BC TNC 26/75/FM 96 00 03 CT-T1+2/3+0-350-FM 37 39 92 PP BCD TNC 25/75/FM 96 00 03 CT-T1+2/3+0-350-FM 37 41 15 PP B TNC 50/100/FM-350 96 02 09 CT-T1/3+0-350-FM 37 41 25 PP B TNS 50/100/FM-350 96 02 07 CT-T1/3+1-350-FM 37 41 35 PP B TT 50/100/FM-350 96 02 07 CT-T1/3+1-350-FM 38 05 24 EP D TNC 275 96 02 04 CT-T3/Y3-275 38 05 25 EP D TNC 275/FM 96 02 05 CT-T3/Y3-275-FM 38 05 30 EP D TNS 275 96 02 04 CT-T3/Y3-275 38 05 31 EP D TNS 275/FM 96 02 05 CT-T3/Y3-275-FM 38 05 35 EP D TT 275 96 02 04 CT-T3/Y3-275 38 05 36 EP D TT 275/FM 96 02 05 CT-T3/Y3-275-FM 38 05 38 EP D TT1+1 275 96 02 02 CT-T3/Y1-275 38 05 39 EP D TT1+1 275/FM 96 02 03 CT-T3/Y1-275-FM 38 05 50 EP D TN 24V/16A 96 01 86 CT-T3/Y1-24 38 05 51 EP D TN 24V/16A/FM 96 01 87 CT-T3/Y1-24-FM 38 05 53 EP D TN 48V/16A 96 01 90 CT-T3/Y1-48 38 05 54 EP D TN 48V/16A/FM 96 01 91 CT-T3/Y1-48-FM 38 05 56 EP D TN 60V/16A 96 01 94 CT-T3/Y1-60 38 05 57 EP D TN 60V/16A/FM 96 01 95 CT-T3/Y1-60-FM 38 05 59 EP D TN 120V/16A 96 01 98 CT-T3/Y1-120 38 05 60 EP D TN 120V/16A/FM 96 01 99 CT-T3/Y1-120-FM 38 05 62 EP D TN 230V/16A 96 02 02 CT-T3/Y1-275 38 05 63 EP D TN 230V/16A/FM 96 02 03 CT-T3/Y1-275-FM 38 09 28 EP C TN 275A 96 01 32 CT-T2/2+0-275-VA 38 09 29 EP C S TN 275A/FM 96 01 33 CT-T2/2+0-275-VA-FM 38 09 30 EP C S TNC 275A 96 01 28 CT-T2/3+0-275-VA 38 09 31 EP C S TNC 275A/FM 96 01 29 CT-T2/3+0-275-VA-FM 38 09 32 EP C S TNS 275A 96 01 26 CT-T2/3+1-275-VA 38 09 33 EP C S TNS 275A/FM 96 01 27 CT-T2/3+1-275-VA-FM 38 09 50 EP C S TN 330A 96 01 46 CT-T2/2+0-350-VA 38 09 51 EP C S TN 330A/FM 96 01 47 CT-T2/2+0-350-VA-FM 38 09 52 EP C S TNC 330A 96 01 42 CT-T2/3+0-350-VA 38 09 53 EP C S TNC 330A/FM 96 01 43 CT-T2/3+0-350-VA-FM 38 09 54 EP C S TNS 330A 96 01 40 CT-T2/3+1-350-VA 38 09 55 EP C S TNS 330A/FM 96 01 41 CT-T2/3+1-350-VA-FM 38 10 24 EP C S TT1+1 275 96 00 50 CT-T2/1+1-275 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Cross reference list power supply systems Previous product nameNew product name Previous product nameNew product name 38 10 25 EP C S TT1+1 275/FM 96 00 51 CT-T2/1+1-275-FM 38 12 70 EP C S T 275 96 01 36 CT-T2/1+0-275-VA 38 10 30 EP C S TNC 275 96 00 44 CT-T2/3+0-275 38 12 75 EP C S T 2757/FM 96 01 37 CT-T2/1+0-275-VA-FM 38 10 35 EP C S TNC 275/FM 96 00 45 CT-T2/3+0-275-FM 38 13 00 EP C S T 440 96 00 80 CT-T2/1+0-440 38 10 40 EP C S TT 275 96 00 42 CT-T2/3+1-275 38 13 05 EP C S T 440/FM 96 00 81 CT-T2/1+0-440-FM 38 10 45 EP C S TT 275/FM 96 00 43 CT-T2/3+1-275-FM 38 13 10 EP C S T 550 96 00 94 CT-T2/1+0-550 38 10 50 EP C S TNS 275 96 00 42 CT-T2/3+1-275 38 13 15 EP C S T 550/FM 96 00 95 CT-T2/1+0-550-FM 38 10 55 EP C S TNS 275/FM 96 00 43 CT-T2/3+1-275-FM 38 20 22 EnerPro 220Tr/20kA 96 01 36 CT-T2/1+0-275-VA 38 11 31 PP B TT1+1 50/100/FM 96 02 15 CT-T1/1+1-350-FM 38 20 23 EnerPro 220Tr/20kA/Pk 96 01 37 CT-T2/1+0-275-VA-FM 38 11 33 PP BC TT1+1 25/100/FM 96 00 09 CT-T1+2/1+1-350-FM 38 50 10 PP BCD TNC 25/75/FM-350 96 00 03 CT-T1+2/3+0-350-FM 38 11 35 PP BCD TT1+1 25/100/FM 96 00 09 CT-T1+2/1+1-350-FM 38 50 30 PP BCD TNS 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 41 IP B TNC 60/100/FM 96 02 09 CT-T1/3+0-350-FM 38 50 50 PP BCD TT 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 71 IPK BC TNC 275/FM 96 00 03 CT-T1+2/3+0-350-FM 38 50 70 PP BCD TN 25/50/FM-350 96 00 07 CT-T1+2/2+0-350-FM 38 11 73 IPK BC TNS 275/FM 96 00 01 CT-T1+2/3+1-350-FM 38 50 90 PP BCD TT1+1 25/100/FM-350 96 00 09 CT-T1+2/1+1-350-FM 38 11 75 IPK BC TT 275/FM 96 00 01 CT-T1+2/3+1-350-FM 38 51 30 PP BC TNC 25/75/FM-350 96 00 03 CT-T1+2/3+0-350-FM 38 11 76 EP C TNC 275 96 01 28 CT-T2/3+0-275-VA 38 51 50 PP BC TNS 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 77 EP C TNC 275/FM 96 01 29 CT-T2/3+0-275-VA-FM 38 51 70 PP BC TT 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 78 EP C TNS 275 96 01 26 CT-T2/3+1-275-VA 38 51 90 PP BC TN 25/50/FM-350 96 00 07 CT-T1+2/2+0-350-FM 38 11 79 EP C TNS 275/FM 96 01 27 CT-T2/3+1-275-VA-FM 38 52 10 PP BC TT1+1 25/100/FM-350 96 00 09 CT-T1+2/1+1-350-FM 38 11 80 EP C TT 275 96 01 26 CT-T2/3+1-275-VA 38 53 10 IP BC TNC 25/75/FM-350 96 00 03 CT-T1+2/3+0-350-FM 38 11 81 EP C TT 275/FM 96 01 27 CT-T2/3+1-275-VA-FM 38 53 50 IP BC TNS 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 82 EP C TT1+1 275 96 01 34 CT-T2/1+1-275-VA 38 53 90 IP BC TT 25/100/FM-350 96 00 01 CT-T1+2/3+1-350-FM 38 11 83 EP C TT1+1 275/FM 96 01 35 CT-T2/1+1-275-VA-FM 38 54 30 IP BC TN 25/50/FM-350 96 00 07 CT-T1+2/2+0-350-FM 38 11 88 EP C TT1+1 350 96 01 48 CT-T2/1+1-350-VA 38 54 70 IP BC TT1+1 25/100/FM-350 96 00 09 CT-T1+2/1+1-350-FM 38 11 91 EP C TT1+1 350/FM 96 01 49 CT-T2/1+1-350-VA-FM 38 54 90 IPK BC TNC 350/FM 96 00 03 CT-T1+2/3+0-350-FM 38 12 11 PP B TN 50/100/FM 96 02 13 CT-T1/2+0-350-FM 38 55 10 IPK BC TNS 350/FM 96 00 01 CT-T1+2/3+1-350-FM 38 12 13 PP BC TN 25/50/FM 96 00 07 CT-T1+2/2+0-350-FM 38 55 30 IPK BC TT 350/FM 96 00 01 CT-T1+2/3+1-350-FM 38 12 15 PP BCD TN 25/50/FM 96 00 07 CT-T1+2/2+0-350-FM 38 55 40 EP C TN 350 96 01 46 CT-T2/2+0-350-VA 38 12 17 IP B TNC 25/75/FM 96 02 09 CT-T1/3+0-350-FM 38 55 50 EP C TN 350/FM 96 01 47 CT-T2/2+0-350-VA-FM 38 12 19 IP BC TNC 25/75/FM 96 00 03 CT-T1+2/3+0-350-FM 38 55 60 EP C TNC 350 96 01 42 CT-T2/3+0-350-VA 38 12 21 IP B TNS 25/100/FM 96 02 07 CT-T1/3+1-350-FM 38 55 70 EP C TNC 350/FM 96 01 43 CT-T2/3+0-350-VA-FM 38 12 23 IP BC TNS 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 38 55 80 EP C TNS 350 96 01 40 CT-T2/3+1-350-VA 38 12 25 IP B TT 25/100/FM 96 02 07 CT-T1/3+1-350-FM 38 55 90 EP C TNS 350/FM 96 01 41 CT-T2/3+1-350-VA-FM 38 12 27 IP BC TT 25/100/FM 96 00 01 CT-T1+2/3+1-350-FM 38 56 00 EP C TT 350 96 01 40 CT-T2/3+1-350-VA 38 12 29 IP B TT1+1 25/50/FM 96 02 15 CT-T1/1+1-350-FM 38 56 10 EP C TT 350/FM 96 01 41 CT-T2/3+1-350-VA-FM 38 12 31 IP BC TT1+1 25/100/FM 96 00 09 CT-T1+2/1+1-350-FM 38 56 40 EP C S TNC 350 96 00 58 CT-T2/3+0-350 38 12 37 IP B TN 25/50/FM 96 02 13 CT-T1/2+0-350-FM 38 56 50 EP C S TNC 350/FM 96 00 59 CT-T2/3+0-350-FM 38 12 39 IP BC TN 25/50/TN 96 00 07 CT-T1+2/2+0-350-FM 38 56 60 EP C S TNS 350 96 00 56 CT-T2/3+1-350 38 12 40 EP C S TN 275 96 00 48 CT-T2/2+0-275 38 56 70 EP C S TNS 350/FM 96 00 57 CT-T2/3+1-350-FM 38 12 41 EP C S TN 275/FM 96 00 49 CT-T2/2+0-275-FM 38 57 00 EP C S TT 350 96 00 56 CT-T2/3+1-350 38 12 47 EP C TN 275 96 01 32 CT-T2/2+0-275-VA 38 57 10 EP C S TT 350/FM 96 00 57 CT-T2/3+1-350-FM 38 12 48 EP C TN 275/FM 96 01 33 CT-T2/2+0-275-VA-FM 38 57 20 EP C S T 350 96 01 50 CT-T2/1+0-350-VA 38 12 54 EP D TN 275 96 02 02 CT-T3/Y1-275 38 57 30 EP C S T 350/FM 96 00 67 CT-T2/1+0-350-FM 38 12 55 EP D TN 275/FM 96 02 03 CT-T3/Y1-275-FM 39 10 22 EnerPro 230CG/10kA 96 01 32 CT-T2/2+0-275-VA Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 7 Network type Description Single-phase power supply Three-phase power supply L1 TN-S Three-phase power supply Separate N and PE L2 L3 N PE L1 TT Three-phase power supply Separate N and PE L2 L3 N PE L1 TN-C Three-phase power supply Common PEN L2 L3 PEN TN-S Single-phase power supply Separate N and PE L1 N PE TT TN-C Single-phase power supply Separate N and PE Single-phase power supply Common PEN L1 N PE L1 PEN * according to the lightning protection zones concept 8 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de L1 L2 L3 N PE L1 L2 L3 N PE L1 L2 L3 PEN L1 N PE L1 N PE L1 PEN selection guide power supply systems Adequate SPD circuit type Product example lightning current arrester type 1, applicable at the LPZ transition point 0A – 1* Product example surge protector type 2, applicable at the LPZ transition point 0B – 1* Product example terminal device protection type 3 arrester, applicable at the LPZ transition point 1 – 2 or higher* 4 + 0 / 3 + 1 CT-T1+2/3+1-350-FM (Item no. 96 00 01) CT-T2/4+0-275-FM (Item no. 96 00 55) CT-T3/Y3-230-FM (Item no. 96 02 05) 3 + 1 CT-T1+2/3+1-350-FM (Item no. 96 00 01) CT-T2/3+1-275-FM (Item no. 96 00 43) CT-T3/Y3-230-FM (Item no. 96 02 05) 3 + 0 CT-T1+2/3+0-350-FM (Item no. 96 00 03) CT-T2/3+0-275-FM (Item no. 96 00 45) 2 + 0 / 1 + 1 CT-T1+2/2+0-350-FM (Item no. 96 00 07) CT-T2/2+0-275-FM (Item no. 96 00 49) CT-T3/Y1-230-FM (Item no. 96 02 03) 1 + 1 CT-T1+2/1+1-350-FM (Item no. 96 00 09) CT-T2/1+1-275-FM (Item no. 96 00 51) CT-T3/Y1-230-FM (Item no. 96 02 03) 1 + 0 CT-T1+2/1+0-350-FM (Item no. 96 00 11) CT-T2/1+0-275-FM (Item no. 96 00 53) Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 9 Surge protection for power supply systems AC power supply 10 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 11 Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1/3+1 Lightning current discharge arrester with raregas-filled spark gap for the use in three-phase TT and TN-S systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 n n Basic circuit diagram n PE L3 n Applicable at the boundaries LPZ 0A - 1 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black N Technical Data CT-T1/3+1-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 / class I UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 100 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / 100 / - kA In 25 / 100 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 2,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 10 kAeff Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 144 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 8 TE Max. operating voltage remote contact 250 V AC/125 V DC Order Data Article-No. 96 02 07 Accessories Product CT-T1-350-M CT-T1-NPE-M Article-No. 96 02 37 96 02 38 Replacement protective plug for lightning current discharge arresters. Product available in 2nd half year 2012 12 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1/3+0 Lightning current discharge arrester with raregas-filled spark gap for the use in three-phase TNC systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 Basic circuit diagram n L3 n Applicable at the boundaries LPZ 0A - 1 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n n PE N Technical Data n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 108 mm n Remote changeover contact CT-T1/3+0-350-FM IEC category/EN type Type 1 / class I Nominal voltage Max. continous operating voltage AC UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 75 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp - / - / 75 (3L-PEN) kA In - / - / 75 (3L-PEN) kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 2,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 10 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 6 TE (108 mm) Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 02 09 Accessories Product CT-T1-350-M Article-No. 96 02 37 Replacement protective plug for lightning current discharge arresters. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 13 Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1/2+0 Lightning current discharge arrester with raregas-filled spark gap for the use in single-phase TN systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 Basic circuit diagram n n Applicable at the boundaries LPZ 0A - 1 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n PE N Technical Data CT-T1/2+0-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 / class I UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 50 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / - / - kA In 25 / - / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 2,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 10 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 72 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 4 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 02 13 Accessories Product CT-T1-350-M Article-No. 96 02 37 Replacement protective plug for lightning current discharge arresters. Product available in 2nd half year 2012 14 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1/1+1 Lightning current discharge arrester with raregas-filled spark gap for the use in single-phase TT and TN systems.They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L PE n Applicable at the boundaries LPZ 0A - 1 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N Technical Data n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 72 mm n Remote changeover contact CT-T1/1+1-350-FM IEC category/EN type Type 1 / class I Nominal voltage Max. continous operating voltage AC UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 50 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / 50 / - kA In 25 / 50 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 2,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 10 kAeff Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 4 TE Max. operating voltage remote contact 250 V AC/125 V DC Order Data Article-No. 96 02 15 Accessories Product CT-T1-350-M CT-T1-NPE-M Article-No. 96 02 37 96 02 38 Replacement protective plug for lightning current discharge arresters. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 15 Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1/1+0 Lightning current discharge arrester with raregas-filled spark gap for the use between L - N wire.They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the boundaries LPZ 0A - 1 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N/PEN Technical Data CT-T1/1+0-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 / class I UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 25 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / - / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp In Up 25 / - / 25 kA ≤ 2,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 10 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 36 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 2 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 02 17 Accessories Product CT-T1-350-M Article-No. 96 02 37 Replacement protective plug for lightning current discharge arresters. Product available in 2nd half year 2012 16 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Lightning current arrester type 1 for AC power supplies Example photo CT-T1-FS Lightning current cappable and rare-gas-filled summation current spark gap for the use between N - PE wire.They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the LPZ transition point 0A-1 respectively 0A-2 Test standard: IEC 61643-1 / EN 61643-11 n n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N/PEN Technical Data n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 36 mm CT-T1/0+1-FS-FM IEC category/EN type Type 1 / class I Nominal voltage UN 230 V Max. continous operating voltage AC Uc 260 V~ Lightning impulse current (10/350) Iimp 100 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp - / 100 / - kA In - / 100 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Up ≤ 2,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Voltage protection level at limp Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 2 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 02 33 Accessories Product CT-T1-NPE-M Article-No. 96 02 38 Replacement protective plug for lightning current capable summation spark gaps. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 17 Surge protection for power supply systems AC power supply 18 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 19 Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1+2/3+1 Lightning current discharge arrester with raregas-filled spark gap and very low protection level < 1 kV for the use in three-phase TT and TN-S systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 n n Basic circuit diagram n PE L3 n Applicable at the boundaries LPZ 0A - 2 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black N Technical Data CT-T1+2/3+1-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 + 2 / class I + II UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 100 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / 100 / - kA In 25 / 100 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 1,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 4 kAeff Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 144 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 8 TE Max. operating voltage remote contact 250 V AC/125 V DC Order Data Article-No. 96 00 01 Accessories Product CT-T1+2-350-M CT-T1-NPE-M Article-No. 96 02 36 96 02 38 Replacement protective plug for combined lightning current discharge and surge arresters. Product available in 2nd half year 2012 20 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1+2/3+0 Lightning current discharge arrester with raregas-filled spark gap and very low protection level < 1 kV for the use in three-phase TNC systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 Basic circuit diagram n L3 n Applicable at the boundaries LPZ 0A - 2 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n n PE N Technical Data n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 108 mm n Remote changeover contact CT-T1+2/3+0-350-FM IEC category/EN type Type 1 + 2 / class I + II Nominal voltage Max. continous operating voltage AC UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 75 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp - / - / 75 (3L-PEN) kA In - / - / 75 (3L-PEN) kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 1,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 4 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 6 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 00 03 Accessories Product CT-T1+2-350-M Article-No. 96 02 36 Replacement protective plug for combined lightning current discharge and surge arresters. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 21 Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1+2/2+0 Lightning current discharge arrester with raregas-filled spark gap and very low protection level < 1 kV for the use in single-phase TN systems. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L1 L2 Basic circuit diagram n n Applicable at the boundaries LPZ 0A - 2 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n PE N Technical Data CT-T1+2/2+0-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 + 2 / class I + II UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 50 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / - / - kA In 25 / - / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 1,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 4 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 72 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 4 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 00 07 Accessories Product CT-T1+2-350-M Article-No. 96 02 36 Replacement protective plug for combined lightning current discharge and surge arresters. Product available in 2nd half year 2012 22 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1+2/1+1 Lightning current discharge arrester with raregas-filled spark gap and very low protection level < 1 kV for the use in single-phase TT and TN systems.They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L PE n Applicable at the boundaries LPZ 0A - 2 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N Technical Data n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 72 mm n Remote changeover contact CT-T1+2/1+1-350-FM IEC category/EN type Type 1 + 2 / class I + II Nominal voltage Max. continous operating voltage AC UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 50 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / 50 / - kA In 25 / 50 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp Up ≤ 1,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 4 kAeff Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 4 TE Max. operating voltage remote contact 250 V AC/125 V DC Order Data Article-No. 96 00 09 Accessories Product CT-T1+2-350-M CT-T1-NPE-M Article-No. 96 02 36 96 02 38 Replacement protective plug for combined lightning current discharge and surge arresters. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 23 Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1+2/1+0 Lightning current discharge arrester with raregas-filled spark gap and very low protection level < 1 kV for the use between L - N wire. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the boundaries LPZ 0A - 2 n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N/PEN Technical Data CT-T1+2/1+0-350-FM IEC category/EN type Nominal voltage Max. continous operating voltage AC Type 1 + 2 / class I + II UN 230/400 V Uc 350 V~ Lightning impulse current (10/350) total Itotal 25 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp 25 / - / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Voltage protection level at limp In Up 25 / - / 25 kA ≤ 1,5 kV Follow current quenching capacity AC L-N (260V AC) Ifi 4 kAeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Space required for installation: 36 mm n Remote changeover contact TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 2 TE Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 00 11 Accessories Product CT-T1+2-350-M Article-No. 96 02 36 Replacement protective plug for combined lightning current discharge and surge arresters. Product available in 2nd half year 2012 24 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Combined arrester type 1 + 2 for AC power supplies Example photo CT-T1-FS Lightning current cappable and rare-gas-filled summation current spark gap for the use between N - PE wire. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the LPZ transition point 0A-1 respectively 0A-2 Test standard: IEC 61643-1 / EN 61643-11 n n Enclosure material: thermoplastic with the colors yellow and black Basic circuit diagram n N/PEN Technical Data n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 n Remote changeover contact CT-T1/0+1-FS-FM IEC category/EN type Nominal voltage UN 230 V Max. continous operating voltage AC Uc 260 V~ Lightning impulse current (10/350) Iimp 100 kA Lightning impulse current (10/350) L-N/N-PE/L-PEN Iimp - / 100 / - kA In - / 100 / - kA Nominal discharge current (8/20) L-N/N-PE/L-PEN Up ≤ 2,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 50 kAeff Voltage protection level at limp Max. acceptable backup fuse (branch wiring) 250 A gL/gG Max. acceptable backup fuse (V-type through wiring) 125 A gL/gG Operating temperature range TU -40 - +80 °C Min. conductor cross section at terminals 10mm² solid/flexible Max. conductor cross section 50mm² stranded/35mm² fexible Dimension (DIN 43880) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Order Data Article-No. 96 02 33 Accessories Product CT-T1-NPE-M Article-No. 96 02 38 Replacement protective plug for lightning current capable summation spark gaps. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 25 Surge protection for power supply systems AC power supply 26 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 27 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/4+0 Fully pluggable surge protective arrester for the use in three-phase TNS systems. FM L2 L3 N Basic circuit diagram L1 n Test standard: IEC 61643-1 / EN 61643-11 n Applicable at the boundaries LPZ 0B - 1 and higher Degree of protection according to IEC EN n 60529: IP 20 PE n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/4+0-150 CT-T2/4+0-150-FM CT-T2/4+0-275 CT-T2/4+0-275-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 120 V 120 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 150 V~ 150 V~ 275 V~ 275 V~ Nominal discharge current (8/20) In 15 kA 15 kA 20 kA 20 kA 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 0,7 kV ≤ 0,7 kV ≤ 1,2 kV ≤ 1,2 kV Protection level at 5 kA Up ≤ 0,5 kV ≤ 0,5 kV ≤ 0,9 kV ≤ 0,9 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 28 96 00 40 96 00 41 96 00 54 96 00 55 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/4+0-350 CT-T2/4+0-350-FM CT-T2/4+0-440 CT-T2/4+0-440-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 350 V~ 350 V~ 440 V~ 440 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 1,5 kV ≤ 1,5 kV ≤ 2,0 kV ≤ 2,0 kV Protection level at 5 kA Up ≤ 1,0 kV ≤ 1,0 kV ≤ 1,5 kV ≤ 1,5 kV Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 68 96 00 69 96 00 82 96 00 83 Accessories Product CT-T2-350-M CT-T2-275-M Article-No. 96 01 85 96 01 84 Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 29 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/3+1 Fully pluggable surge protective arrester for the use in three-phase TT and TNS systems. FM L2 PE L3 Basic circuit diagram L1 n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/3+1-150 CT-T2/3+1-150-FM CT-T2/3+1-275 CT-T2/3+1-275-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 120 V 120 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 150 V~ 150 V~ 275 V~ 275 V~ Nominal discharge current (8/20) In 15 kA 15 kA 20 kA 20 kA 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 0,7 kV ≤ 0,7 kV ≤ 1,2 kV ≤ 1,2 kV Protection level at 5 kA Up ≤ 0,5 kV ≤ 0,5 kV ≤ 0,9 kV ≤ 0,9 kV Protection level N-PE Max. impulse discharge current (8/20) Imax Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 30 96 00 28 96 00 29 96 00 42 96 00 43 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/3+1-350 CT-T2/3+1-350-FM CT-T2/3+1-440 CT-T2/3+1-440-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 350 V~ 350 V~ 440 V~ 440 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Imax Up ≤ 1,5 kV ≤ 1,5 kV ≤ 2,0 kV ≤ 2,0 kV Protection level at 5 kA Up ≤ 1,0 kV ≤ 1,0 kV ≤ 1,5 kV ≤ 1,5 kV Protection level N-PE Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse TU Operating temperature range Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 T 4 TE (72 mm) E 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 56 96 00 57 Product CT-T2-350-M CT-T2-NPE-M Article-No. 96 01 85 96 02 39 96 00 70 96 00 71 Accessories Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 31 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/3+0 Fully pluggable surge protective arrester for the use in three-phase TNC systems. FM L2 Basic circuit diagram L1 L3 n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 PEN n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/3+0-150 CT-T2/3+0-150-FM CT-T2/3+0-275 CT-T2/3+0-275-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 120 V 120 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 150 V~ 150 V~ 275 V~ 275 V~ Nominal discharge current (8/20) In 15 kA 15 kA 20 kA 20 kA 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 0,7 kV ≤ 0,7 kV ≤ 1,2 kV ≤ 1,2 kV Protection level at 5 kA Up ≤ 0,5 kV ≤ 0,5 kV ≤ 0,9 kV ≤ 0,9 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 32 96 00 30 96 00 31 96 00 44 96 00 45 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/3+0-350 CT-T2/3+0-350-FM CT-T2/3+0-440 CT-T2/3+0-440-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 350 V~ 350 V~ 440 V~ 440 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 1,5 kV ≤ 1,5 kV ≤ 2,0 kV ≤ 2,0 kV Protection level at 5 kA Up ≤ 1,0 kV ≤ 1,0 kV ≤ 1,5 kV ≤ 1,5 kV Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 58 96 00 59 96 00 72 96 00 73 Accessories Product CT-T2-350-M CT-T2-275-M Article-No. 96 01 85 96 01 84 Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 33 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/2+0 Fully pluggable surge protective arrester for the use in single-phase TN systems. FM Basic circuit diagram L1 L2 n Test standard: IEC 61643-1 / EN 61643-11 n Applicable at the boundaries LPZ 0B - 1 and higher Degree of protection according to IEC EN n 60529: IP 20 PEN n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/2+0-150 CT-T2/2+0-150-FM CT-T2/2+0-275 CT-T2/2+0-275-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 120 V 120 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 150 V~ 150 V~ 275 V~ 275 V~ Nominal discharge current (8/20) In 15 kA 15 kA 20 kA 20 kA 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 0,7 kV ≤ 0,7 kV ≤ 1,2 kV ≤ 1,2 kV Protection level at 5 kA Up ≤ 0,5 kV ≤ 0,5 kV ≤ 0,9 kV ≤ 0,9 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 34 96 00 34 96 00 35 96 00 48 96 00 49 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/2+0-350 CT-T2/2+0-350-FM CT-T2/2+0-440 CT-T2/2+0-440-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 350 V~ 350 V~ 440 V~ 440 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 1,5 kV ≤ 1,5 kV ≤ 2,0 kV ≤ 2,0 kV Protection level at 5 kA Up ≤ 1,0 kV ≤ 1,0 kV ≤ 1,5 kV ≤ 1,5 kV Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 62 96 00 63 96 00 76 96 00 77 Accessories Product CT-T2-350-M CT-T2-275-M Article-No. 96 01 85 96 01 84 Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 35 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/1+1 Fully pluggable surge protective arrester for the use in single-phase TT and TN systems. FM Basic circuit diagram L1 PE n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/1+1-150 CT-T2/1+1-150-FM CT-T2/1+1-275 CT-T2/1+1-275-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 120 V 120 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 150 V~ 150 V~ 275 V~ 275 V~ Nominal discharge current (8/20) In 15 kA 15 kA 20 kA 20 kA Protection level at In Up ≤ 0,7 kV ≤ 0,7 kV ≤ 1,2 kV ≤ 1,2 kV Protection level at 5 kA Up ≤ 0,5 kV ≤ 0,5 kV ≤ 0,9 kV ≤ 0,9 kV Protection level N-PE Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 125 A gL/gG Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC Max. impulse discharge current (8/20) Imax 2 TE (36 mm) 2 TE (36 mm) 250 V AC/125 V DC 1 A AC/200 mA DC 40 kA 40 kA 96 00 50 96 00 51 Order Data Article-No. Product available in 2nd half year 2012 36 96 00 36 96 00 37 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/1+1-350 CT-T2/1+1-350-FM CT-T2/1+1-440 CT-T2/1+1-440-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 350 V~ 350 V~ 440 V~ 440 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Imax Up ≤ 1,5 kV ≤ 1,5 kV ≤ 2,0 kV ≤ 2,0 kV Protection level at 5 kA Up ≤ 1,0 kV ≤ 1,0 kV ≤ 1,5 kV ≤ 1,5 kV Protection level N-PE Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse TU Operating temperature range Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1,5 Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 64 96 00 65 Product CT-T2-350-M CT-T2-NPE-M Article-No. 96 01 85 96 02 39 96 00 78 96 00 79 Accessories Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 37 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/1+0 Fully pluggable surge protective arrester for the use between L - N wires. FM Basic circuit diagram L n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N/PEN n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/1+0-75 CT-T2/1+0-75-FM CT-T2/1+0-150 CT-T2/1+0-150-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 60 V 60 V 120 V 120 V Nominal voltage UN Max. continous operating voltage AC Uc 75 V~ 75 V~ 150 V~ 150 V~ Nominal discharge current (8/20) In 10 kA 10 kA 15 kA 15 kA 25 kA 25 kA 40 kA 40 kA Protection level at In Up ≤ 0,4 kV ≤ 0,4 kV ≤ 0,7 kV ≤ 0,7 kV Protection level at 5 kA Up ≤ 0,33 kV ≤ 0,33 kV ≤ 0,5 kV ≤ 0,5 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1,51.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 38 96 00 24 96 00 25 96 00 38 96 00 39 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T2/1+0-275 CT-T2/1+0-275-FM CT-T2/1+0-350 CT-T2/1+0-350-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Max. impulse discharge current (8/20) 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,5 kV ≤ 1,5 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,0 kV ≤ 1,0 kV Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 00 52 96 00 53 96 00 66 96 00 67 Technical Data CT-T2/1+0-440 CT-T2/1+0-440-FM CT-T2/1+0-600 CT-T2/1+0-600-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II Nominal voltage UN 230 V 230 V 400 V 400 V Max. continous operating voltage AC Uc 440 V~ 440 V~ 600 V~ 600 V~ Nominal discharge current (8/20) Max. impulse discharge current (8/20) In 20 kA 20 kA 20 kA 20 kA Imax 40 kA 40 kA 40 kA 40 kA Protection level at In Up ≤ 2,0 kV ≤ 2,0 kV ≤ 2,5 kV ≤ 2,5 kV Protection level at 5 kA Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,8 kV ≤ 1,8 kV Ik 25 kAeff 25 kAeff 25 kAeff 25 kAeff Short-circuit withstand capability at max. back-up fuse Max. allowed prefuse Operating temperature range TU 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Min. conductor cross section at terminals 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Bestelldaten Article-No. 96 00 80 96 00 81 96 00 94 96 00 95 Accessories Product CT-T2-350-M CT-T2-150-M Article-No. 96 01 85 96 01 83 Replacement protective plug for surge protection devices type 2. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 39 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/0+1-FS Type 2 surge cappable and rare-gas-filled summation current spark gap for the use between N - PE wire. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the boundaries LPZ 0B - 1 and higher Test standard: IEC 61643-1 / EN 61643-11 n n Degree of protection according to IEC EN 60529: IP 20 Basic circuit diagram n N/PEN Technical Data CT-T2/0+1-FS CT-T2/0+1-FS-FM IEC category/EN type Type 2 / class II Type 2 / class II Nominal voltage UN 230 V 230 V Max. continous operating voltage AC Uc 260 V~ 260 V~ Nominal discharge current (8/20) In 20 kA 20 kA Imax 40 kA 40 kA Up ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG Max. impulse discharge current (8/20) Protection level N-PE Max. allowed prefuse Operating temperature range -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals TU 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 96 02 34 96 02 35 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 n Optional remote changeover contact Order Data Article-No. Accessories Product CT-T2-NPE-M Article-No. 96 02 39 Replacement protective plug for lightning current capable summation spark gaps. Product available in 2nd half year 2012 40 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 41 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/4+0-VA Fully pluggable and leakage-free surge protective arrester for the use in three-phase TNS systems. FM L2 L3 N Basic circuit diagram L1 n Applicable at the boundaries LPZ 0B - 1 and higher n Enhanced arrestor lifetime due to absence of leakage current n Test standard: IEC 61643-1 / EN 61643-11 PE n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/4+0-275-VA CT-T2/4+0-275-VA-FM CT-T2/4+0-350-VA CT-T2/4+0-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 01 38 96 01 39 96 01 52 96 01 53 Accessories Product CT-T2-350-VA-M CT-T2-275-VA-M Article-No. 96 01 97 96 01 96 Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 42 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/3+1-VA Fully pluggable and leakage-free surge protective arrester for the use in three-phase TT and TNS systems. Enhanced arrestor lifetime due to absence of leakage current. FM L2 PE L3 Basic circuit diagram L1 n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N n Mounting on 35 mm DIN rail n Inflammability class according to UL 94 V0 n Optional remote changeover contacthöher n Prüfnormen: IEC 61643-1 / EN 61643-11 Technical Data CT-T2/3+1-275-VA CT-T2/3+1-275-VA-FM CT-T2/3+1-350-VA CT-T2/3+1-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Protection level N-PE Max. impulse discharge current (8/20) Imax Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) 4 TE (72 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 01 26 96 01 27 Product CT-T2-275-VA-M CT-T2-NPE-M Article-No. 96 01 96 96 02 39 96 01 40 96 01 41 Accessories Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 43 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/3+0-VA Fully pluggable and leakage-free surge protective arrester for the use in three-phase TNC systems. FM L2 Basic circuit diagram L1 L3 n Enhanced arrestor lifetime due to absence of leakage current n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 PEN n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/3+0-275-VA CT-T2/3+0-275-VA-FM CT-T2/3+0-350-VA CT-T2/3+0-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 01 28 96 01 29 96 01 42 96 01 43 Accessories Product CT-T2-350-VA-M CT-T2-275-VA-M Article-No. 96 01 97 96 01 96 Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 44 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/2+0-VA Fully pluggable and leakage-free surge protective arrester for the use in single-phase TN systems. FM Basic circuit diagram L1 L2 n Applicable at the boundaries LPZ 0B - 1 and higher n Enhanced arrestor lifetime due to absence of leakage current n Test standard: IEC 61643-1 / EN 61643-11 PEN n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/2+0-275-VA CT-T2/2+0-275-VA-FM CT-T2/2+0-350-VA CT-T2/2+0-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 01 32 96 01 33 96 01 46 96 01 47 Accessories Product CT-T2-350-VA-M CT-T2-275-VA-M Article-No. 96 01 97 96 01 96 Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 45 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/1+1-VA Fully pluggable and leakage-free surge protective arrester for the use in single-phase TT and TN systems. FM Basic circuit diagram L1 PE n Enhanced arrestor lifetime due to absence of leakage current n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 N n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/1+1-275-VA CT-T2/1+1-275-VA-FM CT-T2/1+1-350-VA CT-T2/1+1-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Protection level N-PE Max. impulse discharge current (8/20) Imax Up ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 1 A AC/200 mA DC Max. operating current remote contact 1 A AC/200 mA DC 250 V AC/125 V DC Order Data Article-No. 96 01 34 96 01 35 Product CT-T2-275-VA-M CT-T2-NPE-M Article-No. 96 01 96 96 02 39 96 01 48 96 01 49 Accessories Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 46 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies (leakage-current free) Example photo CT-T2/1+0-VA Fully pluggable and leakage-free surge protective arrester for the use between L - N wires. FM Basic circuit diagram L n Applicable at the boundaries LPZ 0B - 1 and higher n Enhanced arrestor lifetime due to absence of leakage current n Test standard: IEC 61643-1 / EN 61643-11 N/PEN n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Inflammability class according to UL 94 V0 Optional remote changeover contact n Technical Data CT-T2/1+0-275-VA CT-T2/1+0-275-VA-FM CT-T2/1+0-350-VA CT-T2/1+0-350-VA-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II 230 V 230 V 230 V 230 V Nominal voltage UN Max. continous operating voltage AC Uc 275 V~ 275 V~ 350 V~ 350 V~ Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 25 kA 25 kA 25 kA 25 kA Protection level at In Up ≤ 1,2 kV ≤ 1,2 kV ≤ 1,7 kV ≤ 1,7 kV Protection level at 5 kA Up ≤ 0,9 kV ≤ 0,9 kV ≤ 1,3 kV ≤ 1,3 kV Max. impulse discharge current (8/20) Short-circuit withstand capability at max. back-up fuse Imax Ik Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 25 kAeff 25 kAeff 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG 125 A gL/gG 125 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 01 36 96 01 37 96 01 50 96 01 51 Accessories Product CT-T2-350-VA-M CT-T2-275-VA-M Article-No. 96 01 97 96 01 96 Replacement protective plug for leakage-free surge protection devices type 2. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 47 Surge protection for power supply systems AC power supply SPD type 2 for AC power supplies Example photo CT-T2/0+1-FS Type 2 surge cappable and rare-gas-filled summation current spark gap for the use between N - PE wire. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. FM L n Applicable at the boundaries LPZ 0B - 1 and higher Test standard: IEC 61643-1 / EN 61643-11 n n Degree of protection according to IEC EN 60529: IP 20 Basic circuit diagram n N/PEN Technical Data CT-T2/0+1-FS CT-T2/0+1-FS-FM IEC category/EN type Type 2 / class II Type 2 / class II Nominal voltage UN 230 V 230 V Max. continous operating voltage AC Uc 260 V~ 260 V~ Nominal discharge current (8/20) In 20 kA 20 kA Imax 40 kA 40 kA Up ≤ 1,5 kV ≤ 1,5 kV Follow current quenching capacity AC N-PE Ifi 100 Aeff 100 Aeff Short-circuit withstand capability at max. back-up fuse Ik 25 kAeff 25 kAeff 125 A gL/gG 125 A gL/gG Max. impulse discharge current (8/20) Protection level N-PE Max. allowed prefuse Operating temperature range -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals TU 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 96 02 34 96 02 35 n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 n Optional remote changeover contact Order Data Article-No. Accessories Product CT-T2-NPE-M Article-No. 96 02 39 Replacement protective plug for lightning current capable summation spark gaps. Product available in 2nd half year 2012 48 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 49 Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies Example photo CT-T3/Y1 Two-piece pluggable surge protection for singlephase terminal equipment and devices. PE Basic circuit diagram L N 12 11 14 L PE n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N Technical Data CT-T3/Y1-24 CT-T3/Y1-24-FM CT-T3/Y1-48 CT-T3/Y1-48-FM IEC category/EN type Type 3 / class III Type 3 / class III Type 3 / class III Type 3 / class III 24 V 24 V 48 V 48 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 30 V 30 V 60 V 60 V Nominal discharge current (8/20) In 1 kA 1 kA 1 kA 1 kA Total discharge current (8/20) L+N-PE Combined surge generator impulse Itotal 2 kA 2 kA 2 kA 2 kA Uoc 2 kV 2 kV 2 kV 2 kV 4 kV 4 kV 4 kV 4 kV Combined surge generator impulse L+N-PE Protection level L-N Up ≤ 0,18 kV ≤ 0,18 kV ≤ 0,35 kV ≤ 0,35 kV Protection level L/N-PE Up ≤ 0,63 kV ≤ 0,63 kV ≤ 0,73 kV ≤ 0,73 kV Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range Min. conductor cross section at terminals TU 6 kAeff 6 kAeff 6 kAeff 6 kAeff 25 A gL/gG 25 A gL/gG 25 A gL/gG 25 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 0,5mm² solid/flexible 0,5mm² solid/flexible 0,5mm² solid/flexible 0,5mm² solid/flexible Max. conductor cross section 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. Product available in 2nd half year 2012 50 96 01 86 96 01 87 96 01 90 96 01 91 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply Technical Data CT-T3/Y1-60 CT-T3/Y1-60-FM CT-T3/Y1-120 CT-T3/Y1-120-FM IEC category/EN type Type 3 / class III Type 3 / class III Type 3 / class III Type 3 / class III 60 V 60 V 120 V 120 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 75 V 75 V 150 V 150 V Rated load current IL 25 A 25 A 25 A 25 A Nominal discharge current (8/20) Total discharge current (8/20) L+N-PE Combined surge generator impulse In 2 kA 2 kA 2 kA 2 kA Itotal 4 kA 4 kA 4 kA 4 kA Uoc 4 kV 4 kV 4 kV 4 kV Combined surge generator impulse L+N-PE Protection level L-N Up Protection level L/N-PE Up Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range TU 8 kV 8 kV 8 kV 8 kV ≤ 0,40 kV ≤ 0,40 kV ≤ 0,64 kV ≤ 0,64 kV ≤ 0,73 kV ≤ 0,73 kV ≤ 0,80 kV ≤ 0,80 kV 6 kAeff 6 kAeff 6 kAeff 6 kAeff 25 A gL/gG 25 A gL/gG 25 A gL/gG 25 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals 0,5mm² solid/flexible 0,5mm² solid/flexible 0,5mm² solid/flexible 0,5mm² solid/flexible Max. conductor cross section 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Order Data Article-No. 96 01 94 96 01 95 Technical Data CT-T3/Y1-230 CT-T3/Y1-230-FM IEC category/EN type Type 3 / class III Type 3 / class III Nominal voltage UN 230 V 230 V Max. continous operating voltage (DC/AC) Uc 255 V 255 V Rated load current IL 25 A 25 A Nominal discharge current (8/20) In 3 kA 3 kA Itotal 5 kA 5 kA Total discharge current (8/20) L+N-PE Combined surge generator impulse Uoc Combined surge generator impulse L+N-PE 6 kV 6 kV 10 kV 10 kV Protection level L-N Up ≤ 1,25 kV ≤ 1,25 kV Protection level L/N-PE Up ≤ 1,50 kV ≤ 1,50 kV Short-circuit withstand capability at max. back-up fuse Ik Max. allowed prefuse Operating temperature range TU 6 kAeff 6 kAeff 25 A gL/gG 25 A gL/gG -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals 0,5mm² solid/flexible 0,5mm² solid/flexible Max. conductor cross section 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible Dimension (DIN 43880) 1 TE (18 mm) 1 TE (18 mm) Max. operating voltage remote contact 96 01 98 96 01 99 250 V AC/125 V DC Order Data Article-No. 96 02 02 96 02 03 Accessories Product CT-T3/Y1-230-M CT-T3/Y1-24-M Article-No. 96 02 44 96 02 40 Replacement protective plug for single-phase surge protection devices type 3. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 51 Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies Example photo CT-T3/Y3 Two-piece pluggable surge protection for threephase terminal equipment and devices. Basic circuit diagram L1 L1 L2 L2 L3 L3 12 11 14 PE PE n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 N N Technical Data CT-T3/Y3-230 CT-T3/Y3-230-FM IEC category/EN type Type 3 / class III Type 3 / class III Nominal voltage UN 230 V 230 V Max. continous operating voltage (DC/AC) Uc 255 V 255 V Rated load current IL 25 A 25 A Nominal discharge current (8/20) In 3 kA 3 kA Itotal 8 kA 8 kA Uoc 6 kV 6 kV Total discharge current (8/20) L1+L2+L3+N-PE Combined surge generator impulse Combined surge generator impulse L1+L2+L3+N-PE 16 kV 16 kV Protection level L-N Up ≤ 1 kV ≤ 1 kV Protection level L/N-PE Up ≤ 1,5 kV ≤ 1,5 kV Ik 6 kAeff 6 kAeff 25 A gL/gG 25 A gL/gG -40 - +80 °C -40 - +80 °C 0,5mm² solid/flexible Short-circuit withstand capability at max. back-up fuse Max. allowed prefuse Operating temperature range TU Min. conductor cross section at terminals 0,5mm² solid/flexible Max. conductor cross section 4mm² solid/ 2,5mm² flexible 4mm² solid/ 2,5mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n 250 V AC/125 V DC Order Data Article-No. 96 02 04 96 02 05 Accessories Product CT-T3/Y3-230-M Article-No. 96 02 45 Replacement protective plug for three-phase surge protection devices type 3. Product available in 2nd half year 2012 52 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies CombiPro S+ Pluggable combined overvoltage protection for electrical and electronic devices with supply voltage of 230 V. Application for analogue and digital telephone lines, IT networks and SAT aerials input. n SCHUKO plug for 230 V AC supply n With child protection n Power line control by green lamp ON Basic circuit diagram n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Extremely quick response-time (25 ns) n Low protection level Technical Data CPS+ 230 CPS+ 230Tel/Net CPS+ 230SAT CPS+ 230TV IEC category/EN type Type 3 / class III Type 3 / class III Type 3 / class III Type 3 / class III 230 V~ 230 V~ 230 V~ 230 V~ Nominal alternating voltage UN Max. continous operating voltage AC Uc 255 V~ 255 V~ 255 V~ 255 V~ Rated load current IL 16 A 16 A 16 A 16 A Nominal discharge current (8/20) Max. impulse discharge current (8/20) In Imax Maximum allowed voltage Uc Protection level Up 2,5 kA 2,5 kA 2,5 kA 2,5 kA 5 kA 5 kA 5 kA 5 kA -V 180 V/6 V 70 V 70 V 1,5 kV 0,4 kV/0,09 kV 0,3 kV 0,3 kV Installation dimensions (W × H × D) 65 x 100 x 35 mm 65 x 100 x 35 mm 65 x 100 x 35 mm 65 x 100 x 35 mm Type of connection % Combo Jack RJ45 IEC F 32 50 00 32 50 01 32 50 02 32 50 03 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 53 Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies EnerPro D 230 SM Universally useable device to protect equipment and devices up to 16 A power consumption against overvoltages. With test plug and acoustic fault indication. Basic circuit diagram n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Universal device for use in cable ducts and holder boxes Technical Data EP D 230 SM IEC category/EN type Type 3 / class III Nominal alternating voltage UN 230 V~ Max. continous operating voltage AC Uc 255 V~ Rated load current IL 16 A 16 A gL/gG Max. allowed prefuse Protection level L-N Up ≤ 0,95 kV Protection level L/N-PE Up ≤ 1,05 kV Nominal discharge current (8/20) Max. impulse discharge current (8/20) In Imax Response time L-N/L,N-PE 2,5 kA 6 kA ≤ 25/≤ 100 ns 6 kA Short-circuit withstand capability with 16 A back-up fuse Operating temperature range n Class III 2-pole mini SPD (fine protection) TU -20 - +80 °C Conductor cross section 3 x 1 mm² Dimensions L x W x H 31 x 20 x 13,5 mm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 Mounting on under-floor systems, cable trys and device installation boxes Order Data Article-No. 36 20 30 Dimension drawing, see pages 220 to 223 54 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies EnerPro D 230 KM Surge arrester for installation systems and terminal equipment with acoustic fault indication. Basic circuit diagram n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Universal device for use in cable ducts and holder boxes Technical Data n Class III 2-pole mini SPD (fine protection) n Protection against longitudinal and transverse voltages for loads up to 16 A EP D 230 KM IEC category/EN type Type 3 / class III Max. continous operating voltage AC Uc 255 V~ 16 A gL/gG Max. allowed prefuse Rated load current IL Protection level L-N Up ≤ 1,25 kV Protection level L/N-PE Up ≤ 1,5 kV Response time L-N/L,N-PE 16 A ≤ 25/≤ 100 ns Nominal discharge current (8/20) Max. impulse discharge current (8/20) In 3 kA Imax 6 kA TU Operating temperature range Combined surge generator impulse Uoc -15 - +60 °C 6 kV Conductor length ca. 100 mm Dimensions L x W x H 36 x 24 x 9 mm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Mounting on under-floor systems, cable trys and device installation boxes Order Data Article-No. 36 20 35 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 55 Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies NM 220V/5kA Surge voltage protection module for the protection of single-phase 230 V equipment with max. 16 A power consumption. PAS/EBB Verbraucher equipment PE L1 L1 PE N N Basic circuit diagram n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Compact module for equipment installation Technical Data NM 220V/5kA IEC category/EN type Nominal alternating voltage Type 3 / class III UN 230 V~ Rated load current IL Protection level L-N Up ≤ 1,0 kV Protection level L/N-PE Up ≤ 1,5 kV Response time tA ≤ 25 ns Nom. discharge current (8/20 μs) line-earth In 5 kA Nominal discharge current (8/20 μs) line-line In 2,5 kA Max. current (8/20 μs) line-line Ig 8 kA Max. current (8/20 μs) line-earth Ig 15 kA Operating temperature range n Protection against longitudinal and transverse voltages No leakage current to PE (leakage-current n free) TU 16 A -20 - +85 °C Mounting 2x M3-screws (25mm) Type of connection 2.5 (screw-type terminals) Max. conductor cross section 2,5 mm² Order Data Article-No. 36 05 22 Dimension drawing, see pages 220 to 223 56 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems AC power supply SPD type 3 for AC power supplies EnerPro 230 SDU Two-pole surge arrester for the protection of electronical devices, for the retrofitting of deep 220 V flush-mounted boxes. Basic circuit diagram n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-1 / EN 61643-11 Technical Data EnerPro 230 SDU IEC category/EN type Type 3 / class III Nominal alternating voltage UN 230 V~ Rated load current IL Protection level L-N Up ≤ 1,25 kV Protection level L/N-PE Up ≤ 1,5 kV Response time tA < 25 ns Nominal discharge current (8/20) In 2,5 kA Max. impulse discharge current (8/20) Operating temperature range Imax TU n Acoustic failure signal n Including disconnection mechanism 16 A 5 kA -20 - +80 °C Type of connection 3-adrig Mounting type Installation in 230V Flush sockets Order Data Article-No. 24 00 02 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 57 Surge protection for power supply systems DC power supply 58 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems DC power supply Lightning current arrester type 1 for DC power supplies SPD type 2 for DC power supplies Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 59 Surge protection for power supply systems DC power supply Lightning current arrester type 1 for DC power supplies PowerPro PV 800 When applied in PV installations, these devices are placed inside the connection box of the solar generator and on the DC side of the inverter. Basic circuit diagram + PE - n Two-pole DC combined modular arrester, class I and II. n Applicable at the LPZ transition point 0A-1 and higher n Test standard: IEC 61643-1 / EN 61643-11 Technical Data PP PV 800 IEC category/EN type Type 1 + 2 / class I + II Type 1 + 2 / class I + II UocSTC 800 V= 800 V= PV voltage PP PV 800/FM Max. continuous operating voltage DC Uc 850 V= 850 V= Protection level at In Up ≤ 2,2 kV ≤ 2,2 kV Protection level at 5 kA Up ≤ 1,8 kV ≤ 1,8 kV Response time tA ≤ 25 ns ≤ 25 ns Lightning impulse current (10/350 µs) per pole Iimp 12,5 kA 12,5 kA Max. impulse discharge current (8/20) Imax 40 kA 40 kA -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals 10 mm² 10 mm² Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Max. connection torque for terminals 4,5 Nm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 IP 20 Dimension (DIN 43880) 2 TE 2 TE Operating temperature range TU n Mounting on 35 mm DIN rail n Space required for installation: 36 mm (2 TE) n Optional remote signalling contact (FM) 4.5 Nm FM contact / contact type break contact Switching capacity 250 V/2 A Order Data Article-No. 37 44 00 37 44 01 Accessories Product DAK 2x 16 Article-No. 17 01 10 Adapter to enable feed-through wiring (V-wiring) for all surge protection modules with only one clamp per phase, such as PP PV 800 and 1000 and other SPDs for power supply systems. Dimension drawing, see pages 220 to 223 60 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems DC power supply Lightning current arrester type 1 for DC power supplies PowerPro PV 1000 When applied in PV installations, these devices are placed inside the connection box of the solar generator and on the DC side of the inverter. Basic circuit diagram + PE - n Two-pole DC combined modular arrester, class I and II. n Applicable at the LPZ transition point 0A-1 and higher n Test standard: IEC 61643-1 / EN 61643-11 Technical Data PP PV 1000 IEC category/EN type Type 1 + Type 2 (class I/class II) Type 1 + Type 2 (class I/class II) UocSTC 1000 V= 1000 V= PV voltage PP PV 1000/FM Max. continuous operating voltage DC Uc 1100 V= 1100 V= Protection level at In Up ≤ 4,2 kV ≤ 4,2 kV Protection level at 5 kA Up ≤ 3.5 kV ≤ 3.5 kV Response time tA ≤ 25 ns ≤ 25 ns Lightning impulse current (10/350 µs) per pole Iimp 12.5 kA 12.5 kA Max. impulse discharge current (8/20) Imax 40 kA 40 kA -40 - +80 °C -40 - +80 °C Min. conductor cross section at terminals 10 mm² 10 mm² Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Max. connection torque for terminals 4.5 Nm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 IP 20 Dimension (DIN 43880) 3 TE 3 TE Operating temperature range TU n Optional remote signalling contact (FM) n Space required for installation: 54 mm (3 TE) n Mounting on 35 mm DIN rail 4.5 Nm FM contact / contact type break contact Switching capacity 250 V/2 A Order Data Article-No. 37 44 02 37 44 03 Accessories Product DAK 2x 16 Article-No. 17 01 10 Adapter to enable feed-through wiring (V-wiring) for all surge protection modules with only one clamp per phase, such as PP PV 800 and 1000 and other SPDs for power supply systems. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 61 Surge protection for power supply systems DC power supply SPD type 2 for DC power supplies Example photo CT PV-T2/2-0 Fully pluggable surge protective device to be used in photovoltaic systems. Suitable fuse-free earthed photovoltaic applications with system voltages up to 600 or 1000 V DC. 12 11 14 + - n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Basic circuit diagram n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 Technical Data CT PV-T2/2-0/600 CT PV-T2/2-0/600-FM CT PV-T2/2-0/1000 CT PV-T2/2-0/1000-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II ≤ 600 V= ≤ 600 V= ≤ 1000 V= ≤ 1000 V= Open-circuit voltage UOC max. Max. continuous operating voltage DC Uc 600 V= 600 V= 1000 V= 1000 V= Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 30 kA 30 kA 30 kA 30 kA Protection Level L+-L- Up 3 kV 3 kV 5 kV 5 kV Operating temperature range TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. impulse discharge current (8/20) Imax Min. conductor cross section at terminals 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) 2 TE (36 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data 96 02 20 96 02 21 Accessories Product CT PV-T2-600-M CT PV-T2-1000-M Article-No. 96 02 46 96 02 47 96 02 22 96 02 23 Example photo Article-No. Replacement protective plug for DC surge arresters typ 2. Product available in 2nd half year 2012 62 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems DC power supply SPD type 2 for DC power supplies Example photo CT PV-T2/2+1 Fully pluggable surge protective device to be used in photovoltaic systems. Suitable fuse-free earthed photovoltaic applications with system voltages up to 600 or 1000 V DC. 12 11 14 + PE - n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic with the colors yellow and black n Inflammability class according to UL 94 V0 Optional remote changeover contact n Basic circuit diagram n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-1 / EN 61643-11 n Degree of protection according to IEC EN 60529: IP 20 Technical Data CT PV-T2/2+1/600 CT PV-T2/2+1/600-FM CT PV-T2/2+1/1000 CT PV-T2/2+1/1000-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II ≤ 600 V= ≤ 600 V= ≤ 1000 V= ≤ 1000 V= Open-circuit voltage UOC max. Max. continuous operating voltage DC Uc 600 V= 600 V= 1000 V= 1000 V= Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 30 kA 30 kA 30 kA 30 kA Protection Level L+-L- Up 3 kV 3 kV 5 kV 5 kV Protection level L+/L--PE Up 3 kV 3 kV 5 kV 5 kV Operating temperature range TU Max. impulse discharge current (8/20) Min. conductor cross section at terminals Imax -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data Article-No. 96 02 24 96 02 25 Product CT PV-T2-600-M CT PV-T2-1000-M Article-No. 96 02 46 96 02 47 96 02 26 96 02 27 Example photo Accessories Replacement protective plug for DC surge arresters typ 2. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 63 Surge protection for power supply systems DC power supply SPD type 2 for DC power supplies Example photo CT PV-T2/2+GDT Fully pluggable and leakage-free surge protective arrester for the use in photovoltaic applications. Suitable fuse-free earthed photovoltaic applications with system voltages up to 600 or 1000 V DC. 12 11 14 + PE - n Degree of protection according to IEC EN 60529: IP 20 Inflammability class according to UL 94 V0 n n Optional remote changeover contact Basic circuit diagram n Applicable at the boundaries LPZ 0B - 1 and higher n Leakage current-free n Test standard: IEC 61643-1 / EN 61643-11 n Mounting on 35 mm DIN rail Technical Data CT PV-T2/2+GDT/600 CT PV-T2/2+GDT/600-FM CT PV-T2/2+GDT/1000 CT PV-T2/2+GDT/1000-FM IEC category/EN type Type 2 / class II Type 2 / class II Type 2 / class II Type 2 / class II ≤ 600 V= ≤ 600 V= ≤ 1000 V= ≤ 1000 V= Open-circuit voltage UOC max. Max. continuous operating voltage DC Uc 600 V= 600 V= 1000 V= 1000 V= Nominal discharge current (8/20) In 15 kA 15 kA 15 kA 15 kA 30 kA 30 kA 30 kA 30 kA Protection Level L+-L- Up 3 kV 3 kV 5 kV 5 kV Protection level L+/L--PE Up 3 kV 3 kV 3,0 kV 3 kV Operating temperature range TU Max. impulse discharge current (8/20) Min. conductor cross section at terminals Imax -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible 1.5mm² solid/flexible Max. conductor cross section 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible 35mm² stranded/25mm² flexible Dimension (DIN 43880) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) 3 TE (54 mm) Max. operating voltage remote contact 250 V AC/125 V DC 250 V AC/125 V DC Max. operating current remote contact 1 A AC/200 mA DC 1 A AC/200 mA DC Order Data 96 02 28 96 02 29 Product CT PV-T2-600-M CT PV-T2-GDT-M Article-No. 96 02 46 96 02 48 Accessories 96 03 00 96 03 01 Example photo Article-No. Replacement protective plug for DC surge arresters typ 2. Product available in 2nd half year 2012 64 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems Accessories Accessories Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 65 Surge protection for power supply systems Accessories UAS 230-Tr All-purpose acoustic signalling device with test key for all surge protection devices with the nominal voltage of UN 230 V. Basic circuit diagram L N 230V 50Hz n For monitoring of remote contacts of surge protection devices n Mounting on 35 mm DIN rail FM FM FM Technical Data UAS 230-Tr Nominal alternating voltage UN 230 V~ Max. continuous operating voltage DC Uc 240 V= Nominal current IN 16 A Max. power 530 (Relais) W Coil resistance 26,9 Ω Max. conductor cross section Operating temperature range 50mm² mehr.... TU -25 - +65 °C Max. cross section of the remote signalling line 1,5 mm² Degree of protection (IEC EN 60529) IP 20 Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Mounting on 35 mm DIN rail (DIN EN 50 022) Order Data Article-No. 35 10 30 Dimension drawing, see pages 220 to 223 66 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for power supply systems Accessories All-purpose busbars The all-purpose busbar is designed to connect the earthing of all Leutron class II and III lightning and surge voltage components which are placed in a compact housing that can be snapped on 35 mm DIN rail (with multi-function terminals for conductors and busbar connectors). Basic circuit diagram n All-purpose busbar for multi-function terminals n For an optimal bridging of the grounding terminals n Available in different lengths Technical Data KA1/2 KA1/4 KA1/6 KA1/8 Description 1 pole; 2 Kämme 1 pole; 4 Kämme 1 pole, 6 Kämme 1 pole; 8 Kämme Net weight / pc 15 g 17 g 19 g 22 g 17 00 10 17 00 20 17 00 30 17 00 40 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 67 The new arresters – interruption-free and impedance-neutral plugging and unplugging without interrupting the signal The two-part protection devices with a construction width of 17.5 mm cover up to seven voltage types. Devices with a one-piece terminal block design and a construction width of only 6.2 mm allow for a high packing density in control cabinets. Convincing application advantages thanks to a symbiosis of design and optimized packing density – Leutron's new arresters for measuring systems and automatic control devices More versatile in use: 68 nOptimized basic modules for direct or indirect shield grounding via gas discharge tubes nOn pluggable surge protective devices the protection module can be detached and replaced without interrupting the signal nVersions for one pair of wires (1DA) with two signal lines and for two pairs of wires (2DA) with four signal lines available Surge protection for measuring systems and automatic control devices Leutron's two-piece arresters for measuring systems and automatic control devices – for all applications and voltage levels. Surge protection for measuring systems and automatic control devices Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 69 Two-piece, pluggable surge arresters New product line »Leutron Data«: nVoltage levels from 50 V to 180 V DC available nFrequency range: Dependent on the voltage level up to 25 MHz Space-saving installation width of only 18 mm required for up to four single wires Impedance-neutral replacing of protection modules Contacting to mounting rail with lightning current carrying capability Wiring connection up to 4 mm2 solid and 2,5 mm 2 flexible Variable shield grounding: Basic modules for direct or indirect shield grounding via gas discharge tube available 70 Surge protection for measuring systems and automatic control devices One-piece surge arresters nVoltage levels from 50 V to 180 V DC available nFrequency range: Dependent on the voltage level up to 25 MHz Space-saving installation width of only 6.2 mm Contacting to mounting rail with lightning current carrying capability Wiring connection up to 4 mm2 solid and 2,5 mm 2 flexible Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 71 cross reference list to select the substituted Products The cross reference list supports the selection of the new MCR product line modules based on the previous wellknown products. The new MCR product line, consist of a base part and a pluggable module. 72 Substituted product nameSubstituted item number DataPro2x1-SDSL-Tr 24 00 18 DP4x1-SDSL-Tr 24 00 20 DataPro2x1-24V-SDSL-Tr 24 00 24 DP2x1-12V/12V-0,3Ohm-Tr 26 12 12 DP2x1-24V/24V-0,3Ohm-Tr 26 24 24 DP2x1-36V/36V-0,3Ohm-Tr 26 36 36 DP2x1-RLC-Tr 27 00 00 IsoProData150V/150V-Tr 27 03 03 DP2x1-150V/150V-Tr 27 04 04 DP2x1-6V/6V-Tr 27 06 06 DP2x1-12V/12V-Tr 27 12 12 DP2x1-15V/15V-Tr 27 15 15 DP2x1-24V/24V-Tr 27 24 24 DP2x1-30V/30V-Tr 27 30 30 DP2x1-36V/36V-Tr 27 36 36 DP2x1-48V/48V-Tr 27 48 48 DP2x1-60V/60V-Tr 27 60 60 DP2x1-80V/80V-Tr 27 80 80 DP3x1-150V/150V-Tr 28 04 04 DP3x1-12V/12V-Tr 28 12 12 DP3x1-15V/15V-Tr 28 15 15 DP3x1-24V/24V-Tr 28 24 24 DP3x1-30V/30V-Tr 28 30 30 DP3x1-36V/36V-Tr 28 36 36 DP3x1-48V/48V-Tr 28 48 48 DP3x1-60V/60V-Tr 28 60 60 DP2x1-RLC/50V-Tr 28 70 50 IsoProData-Tr 27 30 02 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de cross reference list for measuring systems and automatic control devices ModulBasic New MCR products, consisting of modul and basic part MP 1x2 5V-HF ST MP Base 2x2-R MP Base 2x2-R MP 2x2 5V-HF ST MP 1x2 24V-HF ST MP Base 2x2-R MP 1x2 GDT+12V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+24V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+36V Ad-Ad-Pg ST MP Base 2x2-R MP Base 2x2-R MP 1x2 GDT+180V-Ad-Pg ST MP 1x2 GDT+180V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+180V-Ad-Ad-Pg ST MP Base 2x2-R MP Base 2x2-R MP 1x2 GDT+5V-Ad-Ad-Pg ST MP 1x2 GDT+12V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+24V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+24V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+36V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+36V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+48V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+60V-Ad-Ad-Pg ST MP Base 2x2-R MP 1x2 GDT+180V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+180V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+12V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+24V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+24V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+36V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+36V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+48V-Ad-Ad-Pg ST MP Base 2x2-R MP 2x2 GDT+60V-Ad-Ad-Pg ST MP Base 2x2-R MP Base 2x2-R MP 1x2 GDT+48V-Ad-Pg ST MP 1x2 GDT ST MP Base Item number modulItem number basic 97 10 52 97 00 00 97 10 50 97 00 00 97 10 53 97 00 00 97 00 47 97 00 00 97 00 48 97 00 00 97 00 49 97 00 00 97 00 38 97 00 00 97 00 52 97 00 00 97 00 52 97 00 00 97 00 46 97 00 00 97 00 47 97 00 00 97 00 48 97 00 00 97 00 48 97 00 00 97 00 49 97 00 00 97 00 49 97 00 00 97 00 50 97 00 00 97 00 51 97 00 00 97 00 52 97 00 00 97 00 45 97 00 00 97 00 40 97 00 00 97 00 41 97 00 00 97 00 41 97 00 00 97 00 42 97 00 00 97 00 42 97 00 00 97 00 43 97 00 00 97 00 44 97 00 00 97 00 36 97 00 00 97 00 10 97 00 02 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 73 Interface / SignalConnectionProtected linesProtection deviceItem no.Page 74 -20 mA, 4-20 mA (also with HART) screw terminals screw terminals screw terminals screw terminals 4 2 2 2 MP 2x2 GDT+24V-Ad-Pg ST MP 1x2 GDT+24V-Ad-Ad ST MP RK GDT+24V-Ad-Pg MP RK 24V-Ad-Pg 97 00 27 97 00 20 97 10 13 97 10 34 88 86 108 118 4-20 mA (also with HART) acc. to NAMUR-Empfehlung recommendationNE 21 or acc. EN 61000-4-5, Open-circuit voltage 1 kV Ad-Pg screw terminals screw terminals screw terminals LSA LSA 4 2 2 2 20 MP 2x2 GDT+24V-Ad-Ad ST MP 1x2 GDT+24V-Ad-Ad ST MP RK GDT+24V-Ad-Ad DP 1LSA-24 DP 10LSA-24V 97 00 13 97 00 20 97 10 06 24 00 34 24 00 27 84 86 106 138 147 3/4-Signal Measurement screw terminals 4 MP 2x2 GDT+24V-Ad-Pg ST 97 00 27 88 ADVANT screw terminals screw terminals screw terminals 4 2 2 MP 2x2 GDT+5V-Ad-Ad-Pg ST MP 1x2 GDT+5V-Ad-Ad-Pg ST MP RK GDT+5V-Ad-Ad-Pg 97 00 39 97 00 46 97 10 18 92 94 110 Binary signals screw terminals screw terminals 4 2 MP 2x2 GDT+XXV-Ad-Pg ST MP 1x2 GDT+XXV-Ad-Pg ST 97 00 25 - 97 00 31 97 00 32 - 97 00 38 89 91 screw terminals screw terminals LSA LSA 2 2 2 20 MP RK GDT+XXV-Ad-Pg MP RK XXV-Ad-Pg DP 1LSA-XX DP 10LSA-24V 97 10 11 - 97 10 17 97 10 32 - 97 10 38 24 00 31 - 24 00 39 24 00 27 108 116 138 147 Bitbus screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 BLN (Building Level Network) screw terminals screw terminals screw terminals screw terminals screw terminals screw terminals 4 4 2 2 2 2 MP 2x2 GDT+12V-Ad-Ad ST MP 2x2 GDT+48V-Ad-Ad ST MP 1x2 GDT+12V-Ad-Ad ST MP 1x2 GDT+48V-Ad-Ad ST MP RK GDT+12V-Ad-Ad MP RK GDT+48V-Ad-Ad 97 00 12 97 00 15 97 00 19 97 00 22 97 10 05 97 10 08 84 85 86 87 106 107 CAN-Bus (data line only) screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 C-Bus (Honeywell) Data Highway Plus screw terminals screw terminals screw terminals screw terminals 4 2 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST MP 2x2 GDT+12V-Ad-Ad ST MP 1x2 GDT+12V-Ad-Ad ST 97 10 50 97 10 52 97 00 12 97 00 19 98 99 84 86 Delta Net Peer Bus screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 Device Net (data line only) screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 Dupline screw terminals 2 MP 1x2 GDT+24V-Ad-Ad ST 97 00 20 86 E-Bus (Honeywell) screw terminals screw terminals 4 2 MP 2x2 GDT+48V-Ad-Ad ST MP 1x2 GDT+48V-Ad-Ad ST 97 00 15 97 00 22 85 111 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Selection Guide for measuring systems and automatic control devices Interface / SignalConnectionProtected linesProtection deviceItem no.Page EIB screw terminals 4 MP 2x2 GDT ST 97 00 07 80 screw terminals 2 MP 1x2 GDT ST 97 00 10 81 screw terminals 2 MP RK GDT 97 10 03 102 LSA 20 TelPro LSA-3EH230F1E-10kA 24 01 23 136 Electro acoustic system (ELA) screw terminals screw terminals screw terminals screw terminals screw terminals screw terminals LSA LSA 4 2 2 4 2 2 2 20 MP 2x2 GDT ST MP 1x2 GDT ST MP RK GDT MP 2x2 GDT+180V-Ad-Pg ST MP 1x2 GDT+180V-Ad-Pg ST MP RK GDT+180V-Ad-Pg DP 1LSA-110 DP 10LSA-110 97 00 07 97 00 10 97 10 03 97 00 31 97 00 38 97 10 17 24 00 39 24 01 40 80 80 102 89 91 109 139 147 ET 200 screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 Fieldbus Foundation screw terminals screw terminals screw terminals LSA 4 2 2 20 MP 2x2 GDT+24V-Ad-Ad ST MP 1x2 GDT+24V-Ad-Ad ST MP RK GDT+24V-Ad-Ad DP 10LSA-24V 97 00 13 97 00 20 97 10 06 24 00 27 84 86 106 147 FIPIO / FIPWAY screw terminals screw terminals screw terminals 4 2 2 MP 2x2 GDT+24V-Ad-Ad ST MP 1x2 GDT+24V-Ad-Ad ST MP RK GDT+24V-Ad-Ad 97 00 13 97 00 20 97 10 06 84 86 106 FIP I/O screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 FSK screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 Genius I/O Bus screw terminals screw terminals screw terminals 4 2 2 MP 2x2 GDT+12V-Ad-Ad ST MP 1x2 GDT+12V-Ad-Ad ST MP RK GDT+12V-Ad-Ad 97 00 12 97 00 19 97 10 05 84 86 106 DC power supply +24/30 V DC screw terminals 2 DP2x1-RLC/50V-Tr 28 70 50 188 IEC-Bus (RS 486) screw terminals screw terminals 4 2 MP 2x2 5V-HF ST MP 1x2 5V-HF ST 97 10 50 97 10 52 98 99 Industrial Ethernet RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 8 8 8 8 x 8 8 x 8 16 x 8 24 x 8 32 x 8 40 x 8 48 x 8 8 DP RJ45-CAT6-48V-Tr DP RJ45 f/f DP 1xRJ45-PoE-Alu DP 8xRJ45-6V-WG DP 1x8RJ45-19“ DP 2x8RJ45-19“ DP 3x8RJ45-19“ DP 4x8RJ45-19“ DP 5x8RJ45-19“ DP 6x8RJ45-19“ CPS+ 230Tel/Net 24 00 05 24 00 11 24 00 21 19 40 50 19 40 13 19 40 23 19 40 33 19 40 43 19 40 53 19 40 63 32 50 01 124 125 126 127 128 128 128 129 129 129 53 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 75 Interface / SignalConnectionProtected linesProtection deviceItem no.Page INTERBUS-INLINE (I/O) screw terminals screw terminals screw terminals 4 2 2 MP 2x2 GDT+48V-Ad-Ad ST MP 1x2 GDT+48V-Ad-Ad ST MP RK GDT+48V-Ad-Ad 97 00 15 97 00 22 97 10 08 85 87 107 INTERBUS-Loop screw terminals 2 MP RK 24V-Ad-Pg 97 10 34 118 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 Interbus INLINE Fernbus screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 K-Bus screw terminals 4 MP 2x2 GDT+24V-Ad-Ad ST 97 00 13 84 screw terminals 2 MP 1x2 GDT+24V-Ad-Ad ST 97 00 20 screw terminals 2 MP RK GDT+24V-Ad-Ad 97 10 06 106 KBR-Energy bus screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 KNX-Bus screw terminals 4 MP 2x2 GDT ST 97 00 07 80 screw terminals 2 MP 1x2 GDT ST 97 00 10 80 screw terminals 2 MP RK GDT 97 10 03 102 LSA 20 TelPro LSA-3EH230F1E-10kA 24 01 23 136 LON - TP/XF 78 screw terminals 4 MP 2x2 GDT+5V-Ad-Ad ST 97 00 11 84 screw terminals 2 MP 1x2 GDT+5V-Ad-Ad ST 97 00 18 86 screw terminals 2 MP RK GDT+5V-Ad-Ad 97 10 04 106 - TP/FTT10 und TP/LPT10 screw terminals 4 MP 2x2 GDT+48V-Ad-Ad ST 97 00 15 85 screw terminals 2 MP 1x2 GDT+48V-Ad-Ad ST 97 00 22 87 screw terminals 2 MP RK GDT+48V-Ad-Ad 97 10 08 107 - TP/FTT 10 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 LUXMATE-Bus screw terminals 4 MP 2x2 GDT+24V-Ad-Ad ST 97 00 13 84 screw terminals 2 MP 1x2 GDT+24V-Ad-Ad ST 97 00 20 86 screw terminals 2 MP RK GDT+24V-Ad-Ad 97 10 06 106 M-Bus screw terminals 4 MP 2x2 GDT+48V-Ad-Ad ST 97 00 15 85 screw terminals 2 MP 1x2 GDT+48V-Ad-Ad ST 97 00 22 87 screw terminals 2 MP RK GDT+48V-Ad-Ad 97 10 08 107 MODBUS screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 MPI Bus screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 N1 LAN screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 N2 Bus screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 (Johnson Controls, LON, FTT 10) screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 screw terminals 4 MP 2x2 GDT+24V-Ad-Ad-Pg ST 97 00 41 118 Optocoupler Interface 76 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Selection Guide for measuring systems and automatic control devices Interface / SignalConnectionProtected linesProtection deviceItem no.Page screw terminals 2 MP 1x2 GDT+24V-Ad-Ad-Pg ST 97 00 48 94 screw terminals 2 MP RK GDT+24V-Ad-Ad-Pg 97 10 20 110 Procontic SC31 screw terminals 2 MP 2x2 GDT+12V-Ad-Pg ST 97 00 26 88 (RS 232) screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 Procontic T200 (RS 422) PROFIBUS-DP/FMS screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 PROFIBUS-PA screw terminals 4 MP 2x2 GDT+24V-Ad-Ad ST 97 00 13 84 screw terminals 2 MP 1x2 GDT+24V-Ad-Ad ST 97 00 20 86 screw terminals 2 MP RK GDT+24V-Ad-Ad 97 10 06 106 LSA 2 DP 1LSA-C24FS-PTC 24 00 66 145 PROFIBUS SIMATIC NET screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 PSM-EG-RS 422 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 PSM-EG-RS 485 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 Rackbus (RS 485) screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 R-Bus screw terminals 4 MP 2x2 GDT+5V-Ad-Ad ST 97 00 11 84 screw terminals 2 MP 1x2 GDT+5V-Ad-Ad ST 97 00 18 86 screw terminals 2 MP RK GDT+5V-Ad-Ad 97 10 04 106 RS 485 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 LSA 2 DP 1LSA-C24FS-PTC 24 00 66 145 RS 422, V11 screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 S-Bus screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 SafetyBUS p screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 SDLC screw terminals 4 MP 2x2 5V-HF ST 97 10 50 98 screw terminals 2 MP 1x2 5V-HF ST 97 10 52 99 screw terminals 4 MP 2x2 GDT+5V-Ad-Ad ST 97 00 11 84 Securilan-LON-Bus (LONWORKS Technology screw terminals 2 MP 1x2 GDT+5V-Ad-Ad ST 97 00 18 86 standard bus based on Echelon) screw terminals 2 MP RK GDT+5V-Ad-Ad 97 10 04 106 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 77 Selection Guide for measuring systems and automatic control devices Interface / SignalConnectionProtected linesProtection deviceItem no.Page SIGMASYS Screw connecter 4 MP 2x2 GDT+48V-Ad-Ad ST 97 00 15 85 Screw connecter 2 MP 1x2 GDT+48V-Ad-Ad ST 97 00 22 87 (Siemens fire alarm systems) Screw connecter 2 MP RK GDT+48V-Ad-Ad 97 10 08 110 Screw connecter 4 MP 2x2 GDT+48V-Ad-Pg ST 97 00 29 89 Screw connecter 2 MP 1x2 GDT+48V-Ad-Pg ST 97 00 36 91 Screw connecter 2 MP RK GDT+48V-Ad-Pg 97 10 15 109 SINEC L1 Screw connecter 4 MP 2x2 5V-HF ST 97 10 50 98 Screw connecter 2 MP 1x2 5V-HF ST 97 10 52 99 SINEC L2 Screw connecter 4 MP 2x2 5V-HF ST 97 10 50 98 Screw connecter 2 MP 1x2 5V-HF ST 97 10 52 99 Screw connecter 4 MP 2x2 GDT+12V-Ad-Pg ST 97 00 26 88 SS97 SIN/X (RS 232) Screw connecter 2 MP 1x2 GDT+12V-Ad-Pg ST 97 00 33 90 Screw connecter 2 MP RK GDT+12V-Ad-Pg 97 10 12 108 SUCONET Screw connecter 4 MP 2x2 GDT+5V-Ad-Ad ST 97 00 11 84 Screw connecter 2 MP 1x2 GDT+5V-Ad-Ad ST 97 00 18 86 Screw connecter 2 MP RK GDT+5V-Ad-Ad 97 10 04 106 Temperature measuring Screw connecter 4 MP 2x2 GDT+5V-Ad-Pg ST 97 00 25 88 PT 100, PT 1000, Ni 1000, NTC, PTC Screw connecter 2 MP 1x2 GDT+5V-Ad-Pg ST 97 00 32 90 Screw connecter 2 MP RK GDT+5V-Ad-Pg 97 10 11 108 TTL Screw connecter 4 MP 2x2 GDT+12V-Ad-Pg ST 97 00 26 88 Screw connecter 2 MP 1x2 GDT+12V-Ad-Pg ST 97 00 33 90 Screw connecter 2 MP RK GDT+12V-Ad-Pg 97 10 12 108 TTY 4 - 20 mA Screw connecter 4 MP 2x2 GDT+24V-Ad-Pg ST 97 00 27 88 Screw connecter 2 MP 1x2 GDT+24V-Ad-Pg ST 97 00 34 90 Screw connecter 2 MP RK GDT+24V-Ad-Pg 97 10 13108 Screw connecter 2 MP RK 24V-Ad-Pg 97 10 34118 78 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability for MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 79 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability for MCR applications Example photo MP 2x2 GDT ST Fully pluggable two-parts lightning current discharge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 10 9 Basic circuit diagram * 3 4 7 8 11 12 n Protective circuit for 4 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP 2x2 GDT ST IEC category/EN type D1 / C2 / C1 / C3 Nominal voltage UN 180 V Max. continous operating voltage (DC/AC) Uc 180/120 V Nominal current IN 2A Iimp 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 550 V Protection level line-earth at Iimp D1 Up ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V Series resistance per line Max. operating frequency (3 dB) 0 Ω fG typ. 100 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 Conductor cross section (solid/stranded/AWG) Operating temperature range n Applicable at the boundaries LPZ 0A - 1 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm TU -40 - +80 °C Inflammability class according to UL 94 V0 Degree of protection (IEC EN 60529) IP 20 Order Data Article-No. 97 00 07 Accessories Product MP Base 2x2 MP Base 2x2 GDT Article-No. 97 00 03 97 00 04 Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2 has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2 GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Product available in 2nd half year 2012 80 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability for MCR applications Example photo MP 1x2 GDT ST Basic circuit diagram Fully pluggable two-parts lightning current discharge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 n Protective circuit for 2 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 10 9 * 4 3 Technical Data n Applicable at the boundaries LPZ 0A - 1 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm MP 1x2 GDT ST IEC category/EN type D1 / C2 / C1 / C3 Nominal voltage UN 180 V Max. continous operating voltage (DC/AC) Uc 180/120 V Nominal current IN 2A Iimp 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 550 V Protection level line-earth at Iimp D1 Up ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V Series resistance per line 0Ω Max. operating frequency (3 dB) fG 0.2-4.0/0.2-2.5 mm² / 24-12 Conductor cross section (solid/stranded/AWG) Operating temperature range typ. 100 MHz TU -40 - +80 °C Inflammability class according to UL 94 V0 Degree of protection (IEC EN 60529) IP 20 Order Data Article-No. 97 00 10 Accessories Product MP Base 2x2 MP Base 2x2 GDT Article-No. 97 00 03 97 00 04 Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2 has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2 GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 81 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications 82 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 83 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 2x2 GDT/Ad-Ad ST Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 10 9 Basic circuit diagram * 3 4 7 8 11 12 n Protective circuit for 4 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 2x2 GDT+5V-Ad-Ad ST MP 2x2 GDT+12V-Ad-Ad ST MP 2x2 GDT+24V-Ad-Ad ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 2x2 GDT+36V-Ad-Ad ST D1 / C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 26 V ≤ 52 V ≤ 68 V Protection level line-earth at Iimp D1 Up ≤ 550 V ≤ 550 V ≤ 550 V ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 11 97 00 12 97 00 13 97 00 14 Order Data Article-No. Product available in 2nd half year 2012 84 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 2x2 GDT+48V-Ad-Ad ST MP 2x2 GDT+60V-Ad-Ad ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 2x2 GDT+180V-Ad-Ad ST D1 / C2 / C1 / C3 48 V 60 V 180 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 80 V ≤ 110 V ≤ 270 V Protection level line-earth at Iimp D1 Up ≤ 550 V ≤ 550 V ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 15 97 00 16 97 00 17 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 85 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 1x2 GDT/Ad-Ad ST Basic circuit diagram Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 n Protective circuit for 2 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 10 9 * 4 3 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 1x2 GDT+5V-Ad-Ad ST MP 1x2 GDT+12V-Ad-Ad ST MP 1x2 GDT+24V-Ad-Ad ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 1x2 GDT+36V-Ad-Ad ST D1 / C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 26 V ≤ 52 V ≤ 68 V Protection level line-earth at Iimp D1 Up ≤ 550 V ≤ 550 V ≤ 550 V ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 18 97 00 19 97 00 20 97 00 21 Order Data Article-No. Product available in 2nd half year 2012 86 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 1x2 GDT+48V-Ad-Ad ST MP 1x2 GDT+60V-Ad-Ad ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 1x2 GDT+180V-Ad-Ad ST D1 / C2 / C1 / C3 48 V 60 V 180 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 80 V ≤ 110 V ≤ 270 V Protection level line-earth at Iimp D1 Up ≤ 550 V ≤ 550 V ≤ 550 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 22 97 00 23 97 00 24 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 87 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 2x2 GDT/Ad-Pg ST Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 10 9 Basic circuit diagram * 3 4 7 8 11 12 n Protective circuit for 4 signal lines with common ground n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 2x2 GDT+5V-Ad-Pg ST MP 2x2 GDT+12V-Ad-Pg ST MP 2x2 GDT+24V-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 2x2 GDT+36V-Ad-Pg ST D1 / C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 29 V ≤ 50 V ≤ 102 V ≤ 135 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 37 V ≤ 66 V ≤ 85 V Protection level line-line at 1 kV/μs C3 Up ≤ 20 V ≤ 38 V ≤ 90 V ≤ 116 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 25 97 00 26 97 00 27 97 00 28 Order Data Article-No. Product available in 2nd half year 2012 88 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 2x2 GDT+48V-Ad-Pg ST MP 2x2 GDT+60V-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 2x2 GDT+180V-Ad-Pg ST D1 / C2 / C1 / C3 48 V 60 V 180 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 160 V ≤ 220 V ≤ 520 V Protection level line-earth at Iimp D1 Up ≤ 95 V ≤ 125 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 140 V ≤ 180 V ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 29 97 00 30 97 00 31 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 89 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 1x2 GDT/Ad-Pg ST Basic circuit diagram Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 n Protective circuit for 2 signal lines with common ground n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 10 9 * 4 3 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 1x2 GDT+5V-Ad-Pg ST MP 1x2 GDT+12V-Ad-Pg ST MP 1x2 GDT+24V-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 1x2 GDT+36V-Ad-Pg ST D1 / C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 29 V ≤ 50 V ≤ 102 V ≤ 135 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 37 V ≤ 66 V ≤ 85 V Protection level line-line at 1 kV/μs C3 Up ≤ 20 V ≤ 38 V ≤ 90 V ≤ 116 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 32 97 00 33 97 00 34 97 00 35 Order Data Article-No. Product available in 2nd half year 2012 90 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 1x2 GDT+48V-Ad-Pg ST MP 1x2 GDT+60V-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 1x2 GDT+180V-Ad-Pg ST D1 / C2 / C1 / C3 48 V 60 V 180 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 160 V ≤ 220 V ≤ 520 V Protection level line-earth at Iimp D1 Up ≤ 95 V ≤ 125 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 140 V ≤ 180 V ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 36 97 00 37 97 00 38 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 91 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 2x2 GDT/Ad-Ad-Pg ST Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 10 9 Basic circuit diagram * 3 4 7 8 11 12 n Protective circuit for 4 signal lines with common ground n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 2x2 GDT+5V-Ad-Ad-Pg ST MP 2x2 GDT+12V-Ad-Ad-Pg ST MP 2x2 GDT+24V-Ad-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 5V 12 V 24 V 36 V MP 2x2 GDT+36V-Ad-Ad-Pg ST Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) D1 lightning impulse current (10/350 μs) per wire In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 26 V ≤ 52 V ≤ 68 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 37 V ≤ 66 V ≤ 85 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 39 97 00 40 97 00 41 97 00 42 Order Data Article-No. Product available in 2nd half year 2012 92 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 2x2 GDT+48V-Ad-Ad-Pg ST MP 2x2 GDT+60V-Ad-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 48 V 60 V 180 V MP 2x2 GDT+180V-Ad-Ad-Pg ST Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 80 V ≤ 110 V ≤ 270 V Protection level line-earth at Iimp D1 Up ≤ 95 V ≤ 125 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 43 97 00 44 97 00 45 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 93 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD with high discharge cappability and low protection level for MCR applications Example photo MP 1x2 GDT/Ad-Ad-Pg ST Basic circuit diagram Fully pluggable two-parts combined surge arrester for signal lines. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 n Protective circuit for 2 signal lines with common ground n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 10 9 * 4 3 n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm Technical Data MP 1x2 GDT+5V-Ad-Ad-Pg ST MP 1x2 GDT+12V-Ad-Ad-Pg ST MP 1x2 GDT+24V-Ad-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 5V 12 V 24 V 36 V MP 1x2 GDT+36V-Ad-Ad-Pg ST Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) D1 lightning impulse current (10/350 μs) per wire In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 26 V ≤ 52 V ≤ 68 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 37 V ≤ 66 V ≤ 85 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 97 00 46 97 00 47 97 00 48 97 00 49 Order Data Article-No. Product available in 2nd half year 2012 94 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Technical Data MP 1x2 GDT+48V-Ad-Ad-Pg ST MP 1x2 GDT+60V-Ad-Ad-Pg ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 48 V 60 V 180 V MP 1x2 GDT+180V-Ad-Ad-Pg ST Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA Prorection level line-line at Iimp D1 Up ≤ 80 V ≤ 110 V ≤ 270 V Protection level line-earth at Iimp D1 Up ≤ 95 V ≤ 125 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 97 00 50 97 00 51 97 00 52 Product MP Base 2x2-R MP Base 2x2-R GDT Article-No. 97 00 00 97 00 01 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2-R has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2-R GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 95 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications 96 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD for high frequency MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 97 Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD for high frequency MCR applications Example photo MP 2x2 HF ST Fully pluggable two-parts combined surge arrester for signal lines for high frequency applications such as bus systems or video transmission. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. 1 2 5 6 10 9 Basic circuit diagram * 3 4 7 8 11 12 n Protective circuit for 4 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP 2x2 5V-HF ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 2x2 24V-HF ST Nominal voltage UN 5V 24 V Max. continous operating voltage (DC/AC) Uc 6/4 V 33/23 V Nominal current IN 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 52 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 66 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 45 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 45 V 2,2 Ω 2,2 Ω typ. 70 MHz typ. 70 MHz Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range TU n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C Inflammability class according to UL 94 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 97 10 50 97 10 51 Product MP Base 2x2 MP Base 2x2 GDT Article-No. 97 00 03 97 00 04 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2 has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2 GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Product available in 2nd half year 2012 98 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices Pluggable SPD for MCR applications Pluggable SPD for high frequency MCR applications MP 1x2 HF ST Basic circuit diagram 1 2 5 6 Example photo Fully pluggable two-parts combined surge arrester for signal lines for high frequency applications such as bus systems or video transmission. The protective module can be removed for test or maintenance purposes without changeing the line impedance and therefore influencing the signal level. The base part can remain in the instalation without manipulating or removing any wire. n Protective circuit for 2 signal lines without reference to ground potential n Protective plug can be removed without changing the line impedance or influencing the useful signal n Test standard: IEC 61643-21 / EN 61643-21 10 9 * 4 3 Technical Data MP 1x2 5V-HF ST IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 MP 1x2 24V-HF ST Nominal voltage UN 5V 24 V Max. continous operating voltage (DC/AC) Uc 6/4 V 33/23 V Nominal current IN 0,5 A 0,5 A Iimp 2,5 kA 2,5 kA C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Prorection level line-line at Iimp D1 Up ≤ 25 V ≤ 52 V Protection level line-earth at Iimp D1 Up ≤ 27 V ≤ 66 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 45 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 10 V ≤ 45 V 2,2 Ω 2,2 Ω typ. 70 MHz typ. 70 MHz Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range TU n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Enclosure material: thermoplastic n Space required for installation: 17.5 mm 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C Inflammability class according to UL 94 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 97 10 52 97 10 53 Product MP Base 2x2 MP Base 2x2 GDT Article-No. 97 00 03 97 00 04 Order Data Article-No. Accessories Different base parts provide either direct or indirect earthing of the signal shielding: The MP Base 2x2 has the shield connectors 9/10 (GND) linked directly to the DIN rail and to the earth connector. The MP Base 2x2 GDT has a gas discharge tube linked between the shield connectors 9/10 (GND) and the DIN rail and erath connector. Therefore a galvanic insulation between the signal shield and the earth connection (PE) can be reached. Product available in 2nd half year 2012 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 99 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications 100 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability for MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 101 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability for MCR applications Example photo MP RK GDT Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p Basic circuit diagram n Protective circuit for 2 signal lines without reference to ground potential n Applicable at the boundaries LPZ 0B - 1 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK GDT IEC category/EN type C2 / C1 / C3 Nominal voltage UN 180 V Max. continous operating voltage (DC/AC) Uc 180/120 V Nominal current IN 2,0 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA C2 nominal discharge current (8/20 µs) per line In 5 kA Protection level line-line at In C2 Up ≤ 500 V Protection level line-earth at In C2 Up ≤ 500 V Protection level line-line at 1 kV/μs C3 Up ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V Series resistance per line Max. operating frequency (3 dB) 0Ω fG typ. 100 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 Conductor cross section (solid/stranded/AWG) Operating temperature range n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector TU -40 - +80 °C Inflammability class according to UL 94 V0 Degree of protection (IEC EN 60529) IP 20 Enclosure material / colour PA6 / yellow Order Data Article-No. Product available in 2nd half year 2012 102 97 10 03 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability for MCR applications IsoProData-Tr One-piece lightning current discharge arrester for signal lines with a discharge capabillity for use the at the building entry. Basic circuit diagram 1 1p 2 n Protective circuit for 2 signal lines without reference to ground potential n Applicable at the boundaries LPZ 0A - 1 and higher n Lightning current 5 kA (10/350 µs) per wire 2p Technical Data n Test standard: IEC 61643-21 / EN 61643-21 n Space required for installation: 17.5 mm n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 IsoProData-Tr IEC category/EN type D1 / C2 / C1 / C3 Nominal direct voltage UN 150 V= Max. continuous operating voltage DC Uc 170 V= Max. continous operating voltage AC Uc 120 V~ Nominal current IN 1,5 A Leakage current at Uc DC IL ≤ 0.001 µA Response time tA ≤ 50 ns In 20 kA D1 lightning impulse current (10/350 µs) in total C2 nominal discharge current (8/20 µs) Itotal 10 kA D1 lightning impulse current (10/350 μs) per wire Iimp 5 kA Protection level, residual voltage line-earth at In resp. 1 kV/µs Up ≤ 800 V Capacitance, line-earth < 0.005 nF C Risol Insulation resistance Operating temperature range TU >10 GΩ -25 - +85 °C Max. conductor cross section 16 massiv or 6 Litze mit Aderendhülse mm² Installation dimensions (W × H × D) 17,5 x 87 x 58 mm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Order Data Article-No. 27 30 02 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 103 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications 104 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability and low protection level for MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 105 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability and low protection level for MCR applications Example photo MP RK GDT/Ad-Ad Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines without reference to ground potential n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK GDT+5V-Ad-Ad MP RK GDT+12V-Ad-Ad MP RK GDT+24V-Ad-Ad MP RK GDT+36V-Ad-Ad IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 10 kA C2 nominal discharge current (8/20 µs) per line In 5 kA 5 kA 5 kA 5 kA ≤ 13 V ≤ 25 V ≤ 59 V ≤ 75 V Protection level line-line at In C2 Up Protection level line-earth at In C2 Up ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω typ. 1 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow 97 10 04 97 10 05 97 10 06 97 10 07 Order Data Article-No. Product available in 2nd half year 2012 106 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK GDT+48V-Ad-Ad MP RK GDT+60V-Ad-Ad MP RK GDT+180V-Ad-Ad IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 5 kA 5 kA 5 kA Protection level line-line at In C2 C2 nominal discharge current (8/20 µs) per line Up In ≤ 90 V ≤ 120 V ≤ 320 V Protection level line-earth at In C2 Up ≤ 500 V ≤ 500 V ≤ 500 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 500 V ≤ 500 V ≤ 500 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow 97 10 08 97 10 09 97 10 10 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 107 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability and low protection level for MCR applications Example photo MP RK GDT/Ad-Pg Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines with common ground n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK GDT+5V-Ad-Pg MP RK GDT+12V-Ad-Pg MP RK GDT+24V-Ad-Pg MP RK GDT+36V-Ad-Pg IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 10 kA C2 nominal discharge current (8/20 µs) per line In 5 kA 5 kA 5 kA 5 kA ≤ 26 V ≤ 50 V ≤ 118 V ≤ 150 V Protection level line-line at In C2 Up Protection level line-earth at In C2 Up ≤ 13 V ≤ 25 V ≤ 59 V ≤ 75 V Protection level line-line at 1 kV/μs C3 Up ≤ 20 V ≤ 38 V ≤ 90 V ≤ 116 V Protection level line-Pg at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω typ. 1 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow 97 10 11 97 10 12 97 10 13 97 10 14 Order Data Article-No. Product available in 2nd half year 2012 108 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK GDT+48V-Ad-Pg MP RK GDT+60V-Ad-Pg MP RK GDT+180V-Ad-Pg IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 5 kA 5 kA 5 kA Protection level line-line at In C2 C2 nominal discharge current (8/20 µs) per line Up In ≤ 180 V ≤ 240 V ≤ 600 V Protection level line-earth at In C2 Up ≤ 90 V ≤ 120 V ≤ 320 V Protection level line-line at 1 kV/μs C3 Up ≤ 140 V ≤ 180 V ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow 97 10 15 97 10 16 97 10 17 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 109 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with high discharge cappability and low protection level for MCR applications Example photo MP RK GDT/Ad-Ad-Pg Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines with common ground n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK GDT+5V-Ad-Ad-Pg MP RK GDT+12V-Ad-Ad-Pg MP RK GDT+12V-Ad-Ad-Pg MP RK GDT+36V-Ad-Ad-Pg IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 10 kA C2 nominal discharge current (8/20 µs) per line In 5 kA 5 kA 5 kA 5 kA ≤ 13 V ≤ 25 V ≤ 59 V ≤ 75 V Protection level line-line at In C2 Up Protection level line-earth at In C2 Up ≤ 13 V ≤ 25 V ≤ 59 V ≤ 75 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 2,2 Ω 2,2 Ω 2,2 Ω 2,2 Ω typ. 1 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow 97 10 18 97 10 19 97 10 20 97 10 21 Order Data Article-No. Product available in 2nd half year 2012 110 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK GDT+48V-Ad-Ad-Pg MP RK GDT+60V-Ad-Ad-Pg MP RK GDT+180V-Ad-Ad-Pg IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA 10 kA 10 kA 5 kA 5 kA 5 kA Protection level line-line at In C2 C2 nominal discharge current (8/20 µs) per line Up In ≤ 90 V ≤ 120 V ≤ 320 V Protection level line-earth at In C2 Up ≤ 90 V ≤ 120 V ≤ 320 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 2,2 Ω 2,2 Ω 2,2 Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow 97 10 22 97 10 23 97 10 24 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 111 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications 112 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with low protection level for MCR applications Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 113 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with low protection level for MCR applications Example photo MP RK/Ad-Ad Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines without reference to ground potential n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK 5V-Ad-Ad MP RK 12V-Ad-Ad MP RK 24V-Ad-Ad MP RK 36V-Ad-Ad IEC category/EN type C1 / C3 C1 / C3 C1 / C3 C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 2,0 A 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,8 kA 0,8 kA 0,6 kA 0,4 kA C1 nominal discharge current (8/20μs) per line In 0,4 kA 0,4 kA 0,3 kA 0,2 kA Protection level line-line at In C1 Up ≤ 13 V ≤ 25 V ≤ 48 V ≤ 70 V Protection level line-line at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 0Ω 0Ω 0Ω 0Ω typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow Installation width 6,2 mm 6,2 mm 6,2 mm 6,2 mm Mounting on 35 mm DIN rail (EN 60715) 35 mm DIN rail (EN 60715) 35 mm DIN rail (EN 60715) 35 mm DIN rail (EN 60715) 97 10 25 97 10 26 97 10 27 97 10 28 Order Data Article-No. Product available in 2nd half year 2012 114 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK 48V-Ad-Ad MP RK 60V-Ad-Ad MP RK 180V-Ad-Ad IEC category/EN type C1 / C3 C1 / C3 C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/48 V 180/120 V Nominal current IN 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,3 kA 0,24 kA 0,2 kA In 0,15 kA 0,12 kA 0,1 kA Protection level line-line at In C1 C1 nominal discharge current (8/20μs) per line Up ≤ 90 V ≤ 110 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 0Ω 0Ω 0Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow Installation width 6,2 mm 6,2 mm 6,2 mm Mounting on 35 mm DIN rail (EN 60715) 35 mm DIN rail (EN 60715) 35 mm DIN rail (EN 60715) 97 10 29 97 10 30 97 10 31 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 115 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with low protection level for MCR applications Example photo MP RK/Ad-Pg Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines with common ground n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK 5V-Ad-Pg MP RK 12V-Ad-Pg MP RK 24V-Ad-Pg MP RK 36V-Ad-Pg IEC category/EN type C1 / C3 C1 / C3 C1 / C3 C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 2,0 A 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,8 kA 0,8 kA 0,6 kA 0,4 kA C1 nominal discharge current (8/20μs) per line In 0,4 kA 0,4 kA 0,3 kA 0,2 kA Up ≤ 26 V ≤ 50 V ≤ 96 V ≤ 140 V Protection level line-line at In C1 Protection level line-earth at In C1 Up ≤ 13 V ≤ 25 V ≤ 48 V ≤ 70 V Protection level line-line at 1 kV/μs C3 Up ≤ 20 V ≤ 38 V ≤ 90 V ≤ 116 V Protection level line-Pg at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 0Ω 0Ω 0Ω 0Ω typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow 97 10 32 97 10 33 97 10 34 97 10 35 Order Data Article-No. Product available in 2nd half year 2012 116 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK 48V-Ad-Pg MP RK 60V-Ad-Pg MP RK 180V-Ad-Pg IEC category/EN type C1 / C3 C1 / C3 C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,3 kA 0,24 kA 0,2 kA In 0,15 kA 0,12 kA 0,1 kA Protection level line-line at In C1 C1 nominal discharge current (8/20μs) per line Up ≤ 180 V ≤ 220 V ≤ 600 V Protection level line-earth at In C1 Up ≤ 90 V ≤ 110 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 140 V ≤ 180 V ≤ 500 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 0Ω 0Ω 0Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow 97 10 36 97 10 37 97 10 38 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 117 Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications One-piece SPD with low protection level for MCR applications Example photo MP RK/Ad-Ad-Pg Terminal blocks with integrated surge protection can optimize the used space in a control cabinet and at the same time provide high level protection for terminal equipment and devices. 1 1p 2 2p n Mounting on 35 mm DIN rail n 6.2 mm DIN rail module n Earthing via DIN rail or connector Basic circuit diagram n Protective circuit for 2 signal lines with common ground n Applicable at the boundaries LPZ 1 - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Technical Data MP RK 5V-Ad-Ad-Pg MP RK 12V-Ad-Ad-Pg MP RK 24V-Ad-Ad-Pg MP RK 36V-Ad-Ad-Pg IEC category/EN type C1 / C3 C1 / C3 C1 / C3 C1 / C3 5V 12 V 24 V 36 V Nominal voltage UN Max. continous operating voltage (DC/AC) Uc 6/4 V 15/11 V 33/23 V 45/32 V Nominal current IN 2,0 A 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,8 kA 0,8 kA 0,6 kA 0,4 kA C1 nominal discharge current (8/20μs) per line In 0,4 kA 0,4 kA 0,3 kA 0,2 kA Up ≤ 13 V ≤ 25 V ≤ 48 V ≤ 70 V Protection level line-line at In C1 Protection level line-earth at In C1 Up ≤ 13 V ≤ 25 V ≤ 48 V ≤ 70 V Protection level line-line at 1 kV/μs C3 Up ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V Protection level line-Pg at 1 kV/μs C3 Up Series resistance per line Max. operating frequency (3 dB) fG Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 TU ≤ 10 V ≤ 19 V ≤ 45 V ≤ 58 V 0Ω 0Ω 0Ω 0Ω typ. 1,0 MHz typ. 3,0 MHz typ. 6,0 MHz typ. 8,0 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C V0 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow PA6 / yellow 97 10 39 97 10 40 97 10 41 97 10 42 Order Data Article-No. Product available in 2nd half year 2012 118 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for measuring systems and automatic control devices One-piece SPD for MCR applications Technical Data MP RK 48V-Ad-Ad-Pg MP RK 60V-Ad-Ad-Pg MP RK 180V-Ad-Ad-Pg IEC category/EN type C1 / C3 C1 / C3 C1 / C3 Nominal voltage UN 48 V 60 V 180 V Max. continous operating voltage (DC/AC) Uc 54/38 V 70/49 V 180/120 V Nominal current IN 2,0 A 2,0 A 2,0 A C1 nominal discharge current (8/20μs) total In 0,3 kA 0,24 kA 0,2 kA C1 nominal discharge current (8/20μs) per line In 0,15 kA 0,12 kA 0,1 kA Protection level line-line at In C1 Up ≤ 90 V ≤ 110 V ≤ 300 V Protection level line-earth at In C1 Up ≤ 90 V ≤ 110 V ≤ 300 V Protection level line-line at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 70 V ≤ 90 V ≤ 250 V 0Ω 0Ω 0Ω fG typ. 10 MHz typ. 12 MHz typ. 25 MHz 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 0.2-4.0/0.2-2.5 mm² / 24-12 TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Series resistance per line Max. operating frequency (3 dB) Conductor cross section (solid/stranded/AWG) Operating temperature range Inflammability class according to UL 94 V0 V0 V0 Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Enclosure material / colour PA6 / yellow PA6 / yellow PA6 / yellow 97 10 43 97 10 44 97 10 45 Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 119 Comprehensive protection of all communication networks For an unobstructed data transmission it is vital to protect the communication networks against surge voltages. Leutron’s products reliably protect server rooms, workstations, IT and telephone installations against surge voltages – protection concepts for large-scale as well as for small installations are offered. Leutron offers an optimum protection for the communication networks of its clients. Enhanced availability in complex communication environments: 120 nAll-purpose protection devices for all communication networks due to different interfaces and various bandwidths (up to 10 G Ethernet) nThe overvoltage is limited to non-hazardous values with protection levels adapted to the protection-needing equipment n Plug-and-play units for IT installations improve the operational availability Surge protection for information technology and telecommunication installations Well-proven protection of telecommunication installations – scalable in size and layout Surge protection for information technology and telecommunication installations Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 121 Protection of data networks, e.g. Ethernet and LAN RJ45 socket for different interfaces Mounting on rail Protection for LAN up to Cat. 6 (Gbit Ethernet) 122 Suitable for PoE (Power over Ethernet) Surge protection for information technology and telecommunication installations SSCT (LSA) mounting technology Approval for use in Telekom installations Arrester magazines with GDT (gas discharge tubes) up to 10 DA or with fine protection terminal available Cascadable on backmount frames for widespread communication installations, e.g. telecommunication distributors 2-pole gas-filled surge arrester (GDT) with failsafe characteristic Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 123 Surge protection for information technology and telecommunication SPD for communication networks DataPro RJ45-CAT6 Compact surge protective module for the protection of data networks, and network devices such as hubs, switches, server and desktop computer. The adaptor plug style provides an easy application in cable ducts or directly at the terminal equipment. Schirm shield Basic circuit diagram RJ 45 n Suitable for Cat. 6 / class E applications (up to Gbit Ethernet) n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Schirm shield Technical Data n All 8 signal lines (4 pair of wires) are protected simultaneously. n RJ45 SPD for PoE (Power over Ethernet) n Mounting on 35 mm DIN rail DP RJ45-CAT6-48V-Tr IEC category/EN type C2 / C1 / C3 Nominal direct voltage UN 48 V= Max. continuous operating voltage DC Uc 48 V Operating current 1.000 mA C2 nominal discharge current line-line In 0,15 kA C2 nominal discharge current (8/20 µs) total (In) In 10 kA Protection level at In (line-line) Up 150 V Protection level at In (line-earth) Up 550 V Max. frequency fG 250 MHz Response time tA 1 ns Terminal input/output RJ45, shielded Degree of protection (IEC EN 60529) IP 20 Housing material Metall Order Data Article-No. 24 00 05 Dimension drawing, see pages 220 to 223 124 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication SPD for communication networks DataPro RJ45 (f/f) Compact surge protective module for the protection of data networks, and network devices such as hubs, switches, server and desktop computer. The adaptor plug style provides an easy application in cable ducts or directly at the terminal equipment. Schirm shield Basic circuit diagram RJ 45 n Suitable for Cat. 5 / class D applications (up to Gbit Ethernet) n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Schirm shield Technical Data n Compatible to 10Base T / 100Base T n All 8 signal lines (4 pair of wires) are protected simultaneously. DP RJ45 f/f IEC category/EN type C2 / C1 / C3 Nominal direct voltage UN 6 V= Max. continuous operating voltage DC Uc 8 V= C2 nominal discharge current (8/20 µs) In 2,5 kA Protection level at In (8/20 µs) Up 35 V Max. frequency fG 100 MHz Operating temperature range TU -40 - +80 °C Terminal input/output RJ45, shielded Degree of protection (IEC EN 60529) IP 20 Housing material Metall Order Data Article-No. 24 00 11 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 125 Surge protection for information technology and telecommunication SPD for communication networks DataPro-1xRJ45-PoE-Alu Compact surge protective module for the protection of data networks, and network devices such as hubs, switches, server and desktop computer. The adaptor plug style provides an easy application in cable ducts or directly at the terminal equipment. Schirm shield Basic circuit diagram RJ 45 n Suitable for Cat. 5 / class D applications (up to Gbit Ethernet) n Applicable at the boundaries LPZ 0B - 2 and higher n Test standard: IEC 61643-21 / EN 61643-21 Schirm shield Technical Data n Compatible to 10Base T / 100Base T n RJ45 SPD for PoE (Power over Ethernet) n All 8 signal lines (4 pair of wires) are protected simultaneously. DP 1xRJ45-PoE-Alu IEC category/EN type C2 / C1 / C3 Nominal operating voltage UN 48 V= Max. continuous operating voltage DC Uc 60 V Operating current 650 mA Nominal discharge current (8/20 μs) line-line In 0,5 kA Nom. discharge current (8/20 μs) line-earth In 2,0 kA Protection level line-line at 1 kV/μs C3 Up ≤ 180 V Protection level line-Pg at 1 kV/μs C3 Up ≤ 600 V Max. frequency fG ≤ 100 MHz Terminal input/output RJ45, shielded Degree of protection (IEC EN 60529) IP 20 Housing material Metall Order Data Article-No. 24 00 21 Dimension drawing, see pages 220 to 223 126 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication SPD for communication networks DataPro-8xRJ45-6V-WG Compact surge protective module in a wall housing for the protection of data networks and network devices such as hubs, switches, server and desktop computer. Basic circuit diagram IN OUT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 n Applicable at the boundaries LPZ 1 - 2 and higher n RJ45 wall housing for eight ports n Suitable for Cat. 5 / class D applications (up to Gbit Ethernet) Technical Data n Compatible to 10Base T / 100Base T n Test standard: IEC 61643-21 / EN 61643-21 n All 8 signal lines (4 pair of wires) are protected simultaneously. DP 8xRJ45-6V-WG IEC category/EN type C2 / C1 / C3 Nominal direct voltage UN 6 V= Max. continuous operating voltage DC Uc 8,1 V= Nominal current per line (In) 100 mA C1 nominal discharge current (8/20μs) per line In 200 A Imax 2,5 kA C1 protection level line-line at ln Up ≤ 45 V C1 protection level line-earth at In Up ≤ 350 V C3 protection level line-line at 1kV/μs Up ≤ 40 V C3 protection level line-earth at 1 kV/μs (Up) Up ≤ 350 V Response time line-line; line-shield tA ≤ 1 ns Response time line-PE; PE-shield tA < 100 ns Max. frequency fG 100 MHz Operating temperature range TU -40 - +80 °C C2 Total discharge current (8/20μs) line-earth (PE) Terminal input/output 8 x RJ45, shielded Degree of protection (IEC EN 60529) IP 20 Housing material stainless steel Order Data Article-No. 19 40 50 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 127 Surge protection for information technology and telecommunication SPD for communication networks DataPro x8RJ45-19“ Compact surge protective module in 19“ housing with only 1 HE (45 mm) for the protection of data networks and network devices such as hubs, switches, server and desktop computer. Easy installation and wiring in all 19“ distribution and server racks possible. Basic circuit diagram IN OUT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 n Compatible to 10Base T / 100Base T n Test standard: IEC 61643-21 / EN 61643-21 n Additional modules for the protection of up to 24 ports can be installed optionally n All 8 signal lines (4 pair of wires) are protected simultaneously. n Applicable at the boundaries LPZ 1 - 2 and higher n Fully shielded 19“ housing can be equipped with up to 24 RJ45 protection ports. n Suitable for Cat. 5 / class D applications (up to Gbit Ethernet) Technical Data DP 1x8RJ45-19“ DP 2x8RJ45-19“ DP 3x8RJ45-19“ IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 6 V= 6 V= 6 V= Nominal direct voltage UN Max. continuous operating voltage DC Uc Nominal current per line (In) C1 nominal discharge current (8/20μs) per line C2 Total discharge current (8/20μs) line-earth (PE) C1 protection level line-line at ln 8,1 V= 8,1 V= 8,1 V= 100 mA 100 mA 100 mA In 200 A 200 A 200 A Imax 2,5 kA 2,5 kA 2,5 kA Up ≤ 45 V ≤ 45 V ≤ 45 V C1 protection level line-PE at In Up ≤ 350 V ≤ 350 V ≤ 350 V C3 protection level line-line at 1kV/μs Up ≤ 40 V ≤ 40 V ≤ 40 V C3 protection level line-PE at 1kV/μs Up ≤ 350 V ≤ 350 V ≤ 350 V Response time line-line; line-shield tA < 1 ns < 1 ns < 1 ns Response time line-PE; PE-shield tA < 100 ns < 100 ns < 100 ns Max. frequency fG 100 MHz 100 MHz 100 MHz Operating temperature range TU Terminal input/output -40 - +80 °C -40 - +80 °C -40 - +80 °C 8 x RJ45, shielded 16 x RJ45, shielded 24 x RJ45, shielded Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Housing material Stainless steel Stainless steel Stainless steel 19 40 13 19 40 23 19 40 33 Order Data Article-No. Dimension drawing, see pages 220 to 223 128 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication SPD for communication networks DataPro x8RJ45-19“ (32,40,48 Ports) Compact surge protective module in 19“ housing with only 1 HE (45 mm) for the protection of data networks and network devices such as hubs, switches, server and desktop computer. Easy installation and wiring in all 19“ distribution and server racks possible. Basic circuit diagram IN OUT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 n Compatible to 10Base T / 100Base T n Test standard: IEC 61643-21 / EN 61643-21 n Additional modules for the protection of up to 48 ports can be installed optionally n All 8 signal lines (4 pair of wires) are protected simultaneously. n Applicable at the boundaries LPZ 1 - 2 and higher n Fully shielded 19“ housing can be equipped with up to 48 RJ45 protection ports. n Suitable for Cat. 5 / class D applications (up to Gbit Ethernet) Technical Data DP 4x8RJ45-19‘‘ DP 5x8RJ45-19“ DP 6x8RJ45-19“ IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 C2 / C1 / C3 6 V= 6 V= 6 V= Nominal operating voltage UN Max. permissible rated direct voltage Uc Nominal current per line (In) C1 nominal discharge current (8/20μs) per line C2 Total discharge current (8/20μs) line-earth (PE) C1 protection level line-line at ln 8,1 V 8,1 V 8,1 V 100 mA 100 mA 100 mA In 200 A 200 A 200 A Imax 2,5 kA 2,5 kA 2,5 kA Up ≤ 45 V ≤ 45 V ≤ 45 V C1 protection level line-PE at In Up ≤ 350 V ≤ 350 V ≤ 350 V C3 protection level line-line at 1kV/μs Up ≤ 40 V ≤ 40 V ≤ 40 V C3 protection level line-PE at 1kV/μs Up ≤ 350 V ≤ 350 V ≤ 350 V Response time line-line; line-shield tA < 1 ns < 1 ns < 1 ns Response time line-PE; PE-shield tA < 100 ns < 100 ns < 100 ns Max. frequency fG 100 MHz 100 MHz 100 MHz Operating temperature range TU Terminal input/output -40 - +80 °C -40 - +80 °C -40 - +80 °C 32 x RJ45, shielded 40 x RJ45, shielded 48 x RJ45, shielded Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Housing material Stainless steel Stainless steel Stainless steel 19 40 43 19 40 53 19 40 63 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 129 Surge protection for information technology and telecommunication SPD for telecommunication networks DataPro-ISDN-aP Overvoltage protection for RJ45 for ISDN S0 interface. RJ45- 8/ 4 6 protected side unprotected side Basic circuit diagram 3 4 n For ISDN interfaces n Applicable at the boundaries LPZ 0B - 2 and higher n RJ45 socket 5 Technical Data DataPro ISDN-aP IEC category/EN type C2 / C1 / C3 Nominal direct voltage UN 50 V= Max. continuous operating voltage DC Uc ± 6,2 V= Nominal current IN 1,5 A C2 nominal discharge current (8/20 µs) total (In) In 5 kA Protection level at In (line-line) Up ≤ 36 V Protection level at In (line-earth) Up ≤ 460 V Response time tA ≤ 500/≤ 100 ns Insertion loss in a 100 Ω system, typical 0.1 dB bis 10 MHz Max. operating frequency (3 dB) fG 80 MHz Capacitance/1 MHz, typ. C ≤ 25/ ≤ 15 pF TU -40 - +80 °C Operating temperature range n 2-stage, (5-point) coarse and fine protective circuit n Without coding n Test standard: IEC 61643-21 / EN 61643-21 Type of connection screw-type terminals / RJ45 Degree of protection (IEC EN 60529) IP 20 Order Data Article-No. 24 00 13 Dimension drawing, see pages 220 to 223 130 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication SPD for telecommunication networks DataPro-TAE/NFN-aP Surge protective device in a housing for surface mounting for the protection of analog telecommunication wires such as analog TAE or DSL interfaces. TAE / NFN - Cod e a2 protected side unprotected side N b2 E F W L1 Basic circuit diagram N n For analog telephone lines n Fax, modem, answering machine n Emergency dialling devices n Applicable at the boundaries LPZ 0B - 2 and higher L2 Technical Data n TAE connector, code NFN n Standard of the Deutsche Telekom n Test standard: IEC 61643-21 / EN 61643-21 n 2-stage, (5-point) coarse and fine protective circuit DataPro-TAE/NFN-aP IEC category/EN type C2 / C1 / C3 Nominal direct voltage UN 60 V= Max. continuous operating voltage DC Uc 185 V= Nominal current IN 1,5 A C2 nominal discharge current (8/20 µs) total (In) In 5 kA Protection level at In (line-line) Up ≤ 300 V Protection level at In (line-earth) Up ≤ 450 V Response time (line-line)/(ground-ground) tA ≤ 10 / ≤ 50 ns Max. operating frequency (3 dB) fG 1,5 MHz Resistance per path R 1Ω Operating temperature range TU -40 - +80 °C Type of connection screw-type terminals / TAE Degree of protection (IEC EN 60529) IP 20 Order Data Article-No. 24 00 04 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 131 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting 132 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting Surge protective devices for LSA mounting Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 133 Surge protection for information technology and telecommunication Wiring Diagrams for LSA Technology • LSA surge voltage magazines with 10 or 20 gas-filled surge arresters (coarse protection) • Applicable at the LPZ transition point 0A-2 and higher, depending on type • The magazines can be connected to both the connection and the disconnection module 1 DA IN 1 2 3 4 5 6 7 8 9 10 10 DA OU T • Surge voltage protection connector (coarse and fine protection) DP 1LSA or DP 10LSA to equip the LSA disconnection module (white) of the construction form 2 • Applicable at the LPZ transition point 0A-1 and higher, depending on type • The surge voltage protection connectors are only pluggable to the disconnection module • Earthing by a grounding bar, which is 1 DA connected to the backmount frame via the disconnection module unprotected IN b2 a ' 1p FS 10 DA OU T b' 2p protected (p) a1 example: DP 1LSA-12 134 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category D1+C2 TelPro LSA 2/10-2E 8x6 LSA surge voltage protection for two-electrode arresters (8x6 mm) for LSA (IDC) connection and disconnection modules. a1 ' 1p b1' 2p a7' 13p OU T b7' 14p a8 ' 15p OU T b8' 16p a9' 17p OU T b9' 18p a10' 19p OU T b10' 20p OU T For 10 pair s a1 1 IN b1 2 a7 13 IN b7 14 a8 15 IN b8 16 a9 17 IN b9 18 a1 0 19 IN b10 20 n Integrated fail-safe function Basic circuit diagram n Empty and filled magazines n Magazines are fitted with 20 gas-filled surge arresters (GDT) each Technische Daten Nennansprechspannung DC UagN Ansprechstoßspannung bei 1kV/µs Uas TelPro LSA 2/10-2E 8x6 TelPro LSA-2EH230-10kA TelPro LSA-2EH230F-10kA TelPro LSA-2EL230-20kA - V= 230 V= 230 V= 230 V= -V < 650 V < 650 V < 550 V NennableitwechselstromIwn -A 10 A 10 A 20 A D1 Blitzstoßstrom (10/350µs) - kA 2,5 kA 2,5 kA 5 kA Iimp C2 Nennableitstoßstrom (8/20) C3 Schutzpegel Ader-PE bei 1kV/µs Kapazität Ader-Erde In - kA 10 kA 10 kA 20 kA Up -V ≤ 650 V ≤ 650 V ≤ 550 V C - nF ≤ 1,5 pF at 1MHz nF ≤ 1,5 pF at 1MHz nF ≤ 1,5 pF at 1MHz nF -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 24 01 06 24 01 13 24 01 14 24 01 15 BetriebstemperaturbereichTU Bestelldaten Artikel-Nr. Technische Daten Nennansprechspannung DC Ansprechstoßspannung bei 1kV/µs TelPro LSA-2EH350-10kA TelPro LSA-2EH90-10kA UagN 350 V= 90 V= Uas < 800 V < 550 V 20 A 10 A Iimp 2,5 kA 2,5 kA In 10 kA 10 kA ≤ 800 V ≤ 550 V ≤ 1,5 at 1MHz nF ≤ 1,5 at 1MHz nF -40 - +80 °C -40 - +80 °C 24 01 16 24 01 17 NennableitwechselstromIwn D1 Blitzstoßstrom (10/350µs) C2 Nennableitstoßstrom (8/20) C3 Schutzpegel Ader-PE bei 1kV/µs Kapazität Ader-Erde Up C BetriebstemperaturbereichTU Bestelldaten Artikel-Nr. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 135 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category D1+C2 TelPro LSA 2/10-3E 8x13 LSA surge voltage protection for three-electrode arresters (8x13 mm or 8x10 mm) for LSA (IDC) connection and disconnection modules. a1 ' 1p b1' 2p a7' 13p OU T b7' 14p a8 ' 15p OU T b8' 16p a9' 17p OU T b9' 18p a10' 19p OU T b10' 20p OU T For 10 pair s a1 1 IN b1 2 a7 13 IN b7 14 a8 15 IN b8 16 a9 17 IN b9 18 a1 0 19 IN b10 20 Basic circuit diagram n Empty and filled magazines n Magazines are fitted with 10 gas-filled surge arrester (GDT) each n Integrated fail-safe function Technische Daten Nominal DC sparkover voltage Impulse sparkover voltage at 1 kV/μs Nominal alternating discharge current UagN Uas TelPro LSA 2/10-3E 8x13 TelPro LSA 2/10-3EH230E-10kA TelPro LSA-3EH230F1E-10kA TelPro LSA-3EL230E-20kA - V= 230 V= 230 V= 230 V= -V < 650 V < 650 V < 550 V Iwn -A 10 A 10 A 20 A D1 lightning impulse current (10/350 µs) in total Itotal - kA 5 kA 5 kA 10 kA D1 lightning impulse current (10/350 μs) per wire Iimp - kA 2,5 kA 2,5 kA 5 kA C2 nominal discharge current (8/20 µs) total In - kA 10 kA 10 kA 20 kA C2 nominal discharge current (8/20 µs) per line In - kA 5 kA 5 kA 10 kA C3 protection level line-line at 1kV/μs Up -V ≤ 500 V ≤ 500 V ≤ 500 V C3 protection level line-PE at 1kV/μs Up -V ≤ 500 V ≤ 500 V ≤ 500 V ≤ 1,5 at 1MHz nF Capacitance, line-earth Operating temperature range C TU - nF ≤ 1,5 at 1MHz nF -40 - +80 °C -40 - +80 °C 24 01 18 24 01 19 ≤ 1,5 at 1MHz nF -40 - +80 °C Bestelldaten Artikel-Nr. Technische Daten Nominal DC sparkover voltage UagN 24 01 23 TelPro LSA-3EL230F1E-20kA TelPro LSA-3EH90E-10kA TelPro LSA-3EH90F1E-10kA 230 V= 90 V= 90 V= Impulse sparkover voltage at 1 kV/μs Uas < 550 V < 550 V < 550 V Nominal alternating discharge current Iwn 20 A 10 A 10 A D1 lightning impulse current (10/350 µs) in total Itotal 10 kA 5 kA 5 kA D1 lightning impulse current (10/350 μs) per wire Iimp C2 nominal discharge current (8/20 µs) total C2 nominal discharge current (8/20 µs) per line In 2,5 kA 2,5 kA 10 kA 10 kA 10 kA 5 kA 5 kA C3 protection level line-line at 1kV/μs Up ≤ 500 V ≤ 450 V ≤ 500 V C3 protection level line-PE at 1kV/μs Up ≤ 500 V ≤ 450 V ≤ 500 V Capacitance, line-earth Operating temperature range In 5 kA 20 kA C TU ≤ 1,5 at 1MHz nF ≤ 1,5 at 1MHz nF ≤ 1,5pF at 1MHz nF -40 - +80 °C -40 - +80 °C -40 - +80 °C 24 01 25 24 01 26 24 01 27 24 01 24 Order Data Article-No. Dimension drawing, see pages 220 to 223 136 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category D1+C2 TelPro LSA 2/10-2E 8x20 LSA surge voltage protection for two-electrode arresters (8x20 mm) for LSA (IDC) connection and disconnection modules. a1 ' 1p b1' 2p a7' 13p OU T b7' 14p a8 ' 15p OU T b8' 16p a9' 17p OU T b9' 18p a10' 19p OU T b10' 20p OU T For 10 pair s a1 1 IN b1 2 a7 13 IN b7 14 a8 15 IN b8 16 a9 17 IN b9 18 a1 0 19 IN b10 20 Basic circuit diagram n Empty and filled magazines n Magazines are fitted with 20 gas-filled surge arresters (GDT) each n Integrated fail-safe function Technical Data Nominal DC sparkover voltage UagN Impulse sparkover voltage at 1 kV/μs Uas TelPro LSA 2/10-2E 8x20 TelPro LSA-2EY90-20kA TelPro LSA 2EY230-20kA TelPro LSA-2EY350-20kA - V= 90 V= 230 V= 350 V= -V < 550 V < 550 V < 700 V Nominal alternating discharge current Iwn -A 20 A 20 A 20 A D1 lightning impulse current (10/350 µs) Iimp - kA 5 kA 5 kA 5 kA C2 nominal discharge current (8/20 µs) C3 protection level line-PE at 1kV/μs Capacitance, line-earth Operating temperature range In - kA 20 kA 20 kA 20 kA Up -V ≤ 550 V ≤ 550 V ≤ 700 V C - nF ≤ 1,5 at 1MHz nF ≤ 1,5 at 1MHz nF ≤ 1,5 at 1MHz nF -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 24 01 28 24 01 31 24 01 29 24 01 32 TU Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 137 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 1LSA Surge voltage protective module for one pair of wires for measuring and control systems, in LSA (IDC) disconnection modules. The protective module provides coarse and fine protection in LSA systems (construction form 2). Surge voltage protection connector for 1DA, with fail-safe contact. a1 a ' 1p Basic circuit diagram IN OU T FS b2 n Versions for various voltage levels n Two-step, coarse and fine protection n Fail-safe thermal overload protection b' 2p DP 1LSA-5 DP 1LSA-12 DP 1LSA-15 DP 1LSA-24 Nominal direct voltage Technical Data UN 5 V= 12 V= 15 V= 24 V= Max. continuous operating voltage DC Uc 6 V= 14 V= 19 V= 29 V= Nominal alternating voltage UN 3 V~ 8 V~ 12 V~ 15 V~ Max. continous operating voltage AC Uc 4 V~ 10 V~ 12 V~ 20 V~ 150 mA 150 mA 150 mA 100 mA C2 nominal discharge current (8/20 µs) In 5 kA 5 kA 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA 10 kA 10 kA Nominal operating current at 25°C Protection level at 1kV/μs (line-PG) Residual voltage at 1 kV/μs (line-PG) Up ≤ 15 V ≤ 28 V ≤ 40 V ≤ 60 V Ures ≤ 12 V ≤ 22 V ≤ 31 V ≤ 46 V Response time tA ≤ 1 ns ≤ 1 ns ≤ 1 ns ≤ 1 ns Capacitance, line-earth C ≤ 4,5 nF ≤ 2,5 nF ≤ 2 nF ≤ 1,4 nF Series impedance per line at 25°C R 10 Ω 15 Ω 22 Ω 27 Ω Max. transmission frequency (fg) fg 1,6 MHz 2,4 MHz 3,1 MHz 4,2 MHz via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey 24 00 31 24 00 32 24 00 33 24 00 34 Earthing (Grounding) by Operating temperature range Enclosure material / colour TU Order Data Article-No. Dimension drawing, see pages 220 to 223 138 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting Technical Data UN Nominal direct voltage DP 1LSA-30 DP 1LSA-48 DP 1LSA-60 DP 1LSA-110 30 V= 48 V= 60 V= 110 V= Max. continuous operating voltage DC Uc 33 V= 80 V= 100 V= 180 V= Nominal alternating voltage UN 21 V~ 24 V~ 48 V~ 110 V~ Max. continous operating voltage AC Uc Nominal operating current at 25°C 23 V~ 56 V~ 70 V~ 123 V~ 100 mA 150 mA 150 mA 150 mA C2 nominal discharge current (8/20 µs) In 5 kA 5 kA 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA 10 kA 10 kA Up ≤ 70 V ≤ 240 V ≤ 300 V ≤ 600 V Protection level at 1kV/μs (line-PG) Ures ≤ 54 V ≤ 130 V ≤ 180 V ≤ 230 V Response time tA ≤ 1 ns ≤ 25 ns ≤ 25 ns ≤ 25 ns Residual voltage at 1 kV/μs (line-PG) Capacitance, line-earth C ≤ 1 nF ≤ 300 nF ≤ 250 nF ≤ 100 nF Series impedance per line at 25°C R 27 Ω 4,7 Ω 4,7 Ω 4,7 Ω Max. transmission frequency (fg) fg 4,5 MHz 5 MHz 5 MHz 10 MHz via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey 24 00 36 24 00 37 24 00 38 24 00 39 Earthing (Grounding) by Operating temperature range Enclosure material / colour TU Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 139 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 1LSA with PTC Surge protection device for data and signal lines in measuring systems and automatic control devices. Surge voltage protection connector for 1 DA, with surge current protection via PTC thermistors and fail-safe contact for LSA (IDC) disconnection modules. PT C Basic circuit diagram a1 a ' 1p IN OU T FS n Carse and fine protection n Surge current protection via PTC thermistors n Suitable for DC and AC application n Fail-safe thermal overload protection PT C b2 b' 2p DP 1LSA-5-PTC DP 1LSA-12-PTC DP 1LSA-15-PTC DP 1LSA-24-PTC Nominal direct voltage Technical Data UN 5 V= 12 V= 15 V= 24 V= Max. continuous operating voltage DC Uc 6 V= 14 V= 19 V= 29 V= Nominal alternating voltage UN 3 V~ 8 V~ 12 V~ 15 V~ Max. continous operating voltage AC Uc 4 V~ 10 V~ 12 V~ 20 V~ 150 mA 150 mA 150 mA 150 mA C2 nominal discharge current (8/20 µs) In 5 kA 5 kA 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA 10 kA 10 kA Nominal operating current at 25°C Protection level at 1kV/μs (line-PG) Residual voltage at 1 kV/μs (line-PG) Response time Up ≤ 15 V ≤ 28 V ≤ 40 V ≤ 60 V Ures ≤ 12 V ≤ 22 V ≤ 31 V ≤ 46 V tA ≤ 1 ns ≤ 1 ns ≤ 1 ns ≤ 1 ns thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC Thermal overload protection Capacitance, line-earth C ≤ 4,5 nF ≤ 2,5 nF ≤ 2 nF ≤ 1,4 nF Series impedance per line at 25°C R 9 - 11 Ω 9 - 11 Ω 9 - 11 Ω 9 - 11 Ω Max. transmission frequency (fg) fg 1,6 MHz 2,4 MHz 3,1 MHz 4,2 MHz via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey self-extinguishing thermoplastic (POCAN) UL 94 V0, grey 24 00 40 24 00 41 24 00 42 24 00 43 Earthing (Grounding) by Operating temperature range Enclosure material / colour TU Order Data Article-No. Dimension drawing, see pages 220 to 223 140 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting Technical Data UN Nominal direct voltage DP 1LSA-48-PTC DP 1LSA-60-PTC DP 1LSA-110-PTC 48 V= 60 V= 110 V= Max. continuous operating voltage DC Uc 80 V= 100 V= 180 V= Nominal alternating voltage UN 24 V~ 48 V~ 110 V~ Max. continous operating voltage AC Uc Nominal operating current at 25°C 56 V~ 70 V~ 123 V~ 150 mA 150 mA 150 mA C2 nominal discharge current (8/20 µs) In 5 kA 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA 10 kA ≤ 240 V ≤ 300 V ≤ 600 V Protection level at 1kV/μs (line-PG) Residual voltage at 1 kV/μs (line-PG) Response time Up Ures ≤ 130 V ≤ 180 V ≤ 230 V tA ≤ 25 ns ≤ 25 ns ≤ 25 ns thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC Thermal overload protection Capacitance, line-earth C ≤ 300 nF ≤ 250 nF ≤ 100 nF Series impedance per line at 25°C R 9 - 11 Ω 9 - 11 Ω 9 - 11 Ω Max. transmission frequency (fg) fg 5 MHz 5 MHz 10 MHz via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C -40 - +80 °C via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame 24 00 44 24 00 45 24 00 46 Earthing (Grounding) by Operating temperature range Enclosure material / colour TU Order Data Article-No. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 141 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 1LSA-180FS Lightning and surge protection for telephone installations. Pluggable module for LSA (IDC) disconnection modules. Surge voltage protection connector for 1 DA, for ADSL, ISDN Uk0 or a/b lines, with fail-safe contact. a1 a ' 1p Basic circuit diagram IN OU T FS b2 b' 2p Technical Data DP 1LSA-180FS Nominal direct voltage UN 110 V= Max. continuous operating voltage DC Uc 180 V= Uc 127 V~ Max. continous operating voltage AC Nominal DC sparkover voltage at 100V/s C3 protection level at 1 kV/μs (line-PG) UagN Up Nominal operating current at 25°C C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) 230 ±20% V= ≤450 V 150 mA In Imax Alternating discharge current 9 cycles, 50Hz (Iw) 5 kA 10 kA 50 A Response time line1-line2-PG tA Self-capacitance line-earth at 1 MHz C ≤ 3 pF Max. transmission frequency (fg) fg 50 MHz Thermal overload protection thermical fail-safe (short-circuit spring) Earthing (Grounding) by Operating temperature range Enclosure material / colour ≤ 50 ns via grounding bar and isolation unit on LSA backmount frame TU -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey Order Data Article-No. 24 00 47 Dimension drawing, see pages 220 to 223 142 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 1LSA-T110FS-PTC Surge voltage and surge current protection for communication and data transmission lines. Pluggable module for LSA (IDC) disconnection modules. Surge voltage protection connector for 1 DA with surge current protection via PTC thermistors, for analogue, ISDN and ADSL lines. Integrated coarse and fine protection and fail-safe contact. PT C a1 a ' 1p Basic circuit diagram TIS P IN OU T FS PT C b2 b' 2p Technical Data DP 1LSA-T110FS-PTC Nominal direct voltage UN 110 V= Max. continuous operating voltage DC Uc 180 V= Nominal operating current at 25°C 150 mA C2 nominal discharge current (8/20 µs) In 5 kA Max. discharge current (8/20μs) In 10 kA Voltage protection level at isn (ln) (L-PE, L1-L2) Residual voltage at 1 kV/μs (line-PG, line-line) Up ≤ 300 V Ures ≤ 300 V Response time tA ≤ 5 ns Transversal Capacitance C ≤ 60 pF Series impedance per line at 25°C R 9 - 11 Ω Max. transmission frequency (fg) fg > 20 MHz Thermal overload protection thermical fail-safe (short-circuit spring) and PTC Earthing (Grounding) by via grounding bar and isolation unit on LSA backmount frame Operating temperature range Enclosure material / colour TU -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey Order Data Article-No. 24 00 48 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 143 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 1LSA-TK180FS Lightning and surge protection for telephone installations. Pluggable module for LSA (IDC) disconnection modules. Surge voltage protection connector for 1 DA with fail-safe contact (only coarse protection) for analogue, ISDN and ADSL lines. a1 a ' 1p Basic circuit diagram IN FS b2 OU T b' 2p Technical Data DP 1LSA-TK180FS Nominal direct voltage UN 110 V= Max. continuous operating voltage DC Uc 180 V= Nominal DC sparkover voltage at 100V/s C3 protection level at 1 kV/μs (line-PG) UagN Up Nominal operating current at 25°C C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) 230 ±20% V= ≤ 600 V 1000 mA In Imax Alternating discharge current 9 cycles, 50Hz (Iw) 5 kA 10 kA 40 A Response time (line-line)/(ground-ground) tA Self-capacitance line-earth at 1 MHz C ≤ 5 pF Max. transmission frequency (fg) fg > 30 MHz ≤ 50 ns Thermal overload protection thermical fail-safe (short-circuit spring) Earthing (Grounding) by via grounding bar and isolation unit on LSA backmount frame Operating temperature range Enclosure material / colour TU -40 - +80 °C self-extinguishing thermoplastic (POCAN) UL 94 V0, grey Order Data Article-No. 24 00 49 Dimension drawing, see pages 220 to 223 144 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DP 1LSA-CxxFS-PTC Surge voltage protector for data and signal lines in measuring systems and automatic control devices. Surge voltage protection connector for 1 DA with surge current protection via PTC thermistors and fail-safe contact for higher frequency transmission range for measuring systems and automatic control devices, for LSA (IDC) disconnection modules. PT C Basic circuit diagram a1 IN a ' 1p OU T FS PT C b2 n Surge current protection via PTC thermistors n High impulse discharge current of 10 kA (8/20 µs) n Suitable for DC and AC application b' 2p DP 1LSA-C5FS-PTC DP 1LSA-C12FS-PTC DP 1LSA-C15FS-PTC DP 1LSA-C24FS-PTC Nominal direct voltage Technical Data UN 5 V= 12 V= 15 V= 24 V= Max. continuous operating voltage DC Uc 6 V= 14 V= 19 V= 29 V= Nominal alternating voltage UN o.A. V~ 8 V~ 12 V~ 15 V~ Max. continous operating voltage AC Uc o.A. V~ 10 V~ 12 V~ 20 V~ 150 mA 150 mA 150 mA 150 mA C2 nominal discharge current (8/20 µs) In 5 kA 5 kA 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA 10 kA 10 kA Nominal operating current at 25°C Protection level at In (line-line) Up ≤ 11 V ≤ 22 V ≤ 31 V ≤ 46 V Protection level at 1kV/μs (line-PG) Up ≤ 600 V ≤ 600 V ≤ 600 V ≤ 600 V Response time a-b tA Response time a,b to PG ≤ 1 ns ≤ 1 ns ≤ 1 ns ≤ 1 ns 100 ns < 100 ns < 100 ns < 100 ns Transversal Capacitance C ≤ 30 pF ≤ 30 pF ≤ 30 pF ≤ 30 pF Series impedance per line at 25°C R 9 - 11 Ω 9 - 11 Ω 9 - 11 Ω 9 - 11 Ω Max. transmission frequency (fg) fg ≤ 30 MHz ≤ 30 MHz ≤ 30 MHz ≤ 30 MHz Thermal overload protection thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC Earthing (Grounding) by via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C 24 00 63 24 00 64 24 00 65 24 00 66 Operating temperature range TU Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 145 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting Technical Data DP 1LSA-C48FS-PTC DP 1LSA-C60FS-PTC Nominal direct voltage UN 48 V= 60 V= Max. continuous operating voltage DC Uc 80 V= 100 V= Nominal alternating voltage UN 24 V~ 48 V~ Max. continous operating voltage AC Uc 56 V~ 70 V~ 150 mA 150 mA Nominal operating current at 25°C C2 nominal discharge current (8/20 µs) In 5 kA 5 kA Max. discharge current (8/20μs) In 10 kA 10 kA Protection level at In (line-line) Up ≤ 130 V ≤ 180 V Protection level at 1kV/μs (line-PG) Up ≤ 600 V ≤ 600 V Response time a-b tA ≤ 25 ns ≤ 25 ns < 100 ns <100 ns Response time a,b to PG Transversal Capacitance C ≤ 30 pF ≤ 30 pF Series impedance per line at 25°C R 9 - 11 Ω 9 - 11 Ω Max. transmission frequency (fg) fg ≤ 30 MHz ≤ 30 MHz Thermal overload protection thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC Earthing (Grounding) by via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame -40 - +80 °C -40 - +80 °C 24 00 61 24 00 62 Operating temperature range TU Order Data Article-No. 146 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 10LSA Pluggable surge arrester for telecommunication lines with 10 pair of wires (DA) for LSA (IDC) disconnection modules. a1' 1p OU T b1' 2p a7 ' 13p OU T b7' 14p a8 ' 15p OU T b8' 16p a9 ' 17p OU T b9' 18p a10' 19p OU T b10' 20p For 10 DA SI D S ID FS SI D FS S ID FS SI D FS FS for 10 pair s a1 1 IN b1 2 a7 13 IN b7 14 a8 15 IN b8 16 a9 17 IN b9 18 a10 19 IN b10 20 n Surge voltage protection against longitudinal and transverse voltages n PTC surge current protection at DP 10LSAPTC-110 and DP 10LSA-PTC12V Basic circuit diagram n Surge arrester for telecommunications n Protection for up to 10 pair of wires (DA) n Integrated coarse and fine protection DP 10LSA-12V DP 10LSA-24V DP 10LSA-110 Nominal direct voltage Technical Data UN 12 V= 24 V= 110 V= Max. continuous operating voltage DC Uc 14 V= 29 V= 180 V= Uc 10 V~ 21 V~ Ures ≤ 22 V ≤ 46 V ≤ 250 V 150 mA 150 mA 145 mA Max. continous operating voltage AC Residual voltage 1kV/μs Nominal operating current at 25°C C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) In Imax 5 kA 5 kA 5 kA 10 kA 10 kA 10 kA Protection level at In Up ≤ 28 V ≤ 60 V 220 V Response time tA ≤ 1 ns ≤ 1 ns < 1 ns ≤2s ≤2s <2 s Thermal fail-safe response time at 230VAC/23A and ambient TA temperature 25°C Capacitance, line-earth C < 2,5 nF < 1,4 nF < 0,1 nF Serial inductive impedance at 25°C L 47 µH 47 µH 47 µH Series impedance per line at 25°C R 15 Ω 27 Ω 3-6 Ω Max. transmission frequency (fg) fg < 2,4 MHz ≤ 4,2 MHz ≤ 1,2 MHz Montagewanne 0der Montagestange der Trennleiste Montagewanne 0der Montagestange der Trennleiste Montagewanne 0der Montagestange der Trennleiste Earthing (Grounding) by Operating temperature range Enclosure material / colour TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Thermoplastic: grey or yellow Thermoplastic: grey or yellow Thermoplastic: grey or yellow 24 00 25 24 00 27 24 01 40 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 147 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting SPD according to test category C2+C1 DataPro 10LSA-PTC Surge voltage arrester with surge current protection via PTC thermistors. Designed for telecommunication lines as a pluggable module with 10 pair of wires (DA) for LSA (IDC) disconnection modules. a1' 1p OU T a7 ' 13p b1' 2p OU T b7' 14p a8 ' 15p OU T b8' 16p a9 ' 17p OU T b9' 18p a10' 19p OU T b10' 20p For 10 DA SI D S ID FS SI D FS S ID FS SI D FS FS for 10 pair s a1 1 IN b1 2 a7 13 IN b7 14 a8 15 IN b8 16 a9 17 IN b9 18 a10 19 IN b10 20 n Surge voltage protection against longitudinal and transverse voltages n PTC surge current protection at DP 10LSAPTC-110 and DP 10LSA-PTC12V Basic circuit diagram n Surge arrester for telecommunications n Protection for up to 10 pair of wires (DA) n Integrated coarse and fine protection DP 10LSA-PTC-12V DP 10LSA-PTC-24V DP 10LSA-PTC 110 Nominal direct voltage Technical Data UN 12 V= 24 V= 110 V= Max. continuous operating voltage DC Uc 14 V= 29 V= 180 V= Max. continous operating voltage AC Residual voltage 1kV/μs Uc 10 V~ 21 V~ 180 V~ Ures ≤ 22 V ≤ 46 V ≤ 250 V Nominal operating current at 25°C C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) In Imax 150 mA 150 mA 145 mA 5 kA 5 kA 5 kA 10 kA 10 kA 10 kA Protection level at In Up ≤ 28 V ≤ 60 V 220 V Response time tA ≤ 1 ns ≤ 1 ns ≤ 1 ns Capacitance, line-earth C < 2,5 nF Series impedance per line at 25°C R 9 - 11 Ω < 1,4 nF < 0,1 nF 9 - 11 Ω 9 - 11 Ω Max. transmission frequency (fg) fg < 2,4 MHz ≤ 4,2 MHz ≤ 2 MHz Operating temperature range TU -40 - +80 °C -40 - +80 °C -40 - +80 °C Thermal overload protection thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC thermical fail-safe (short-circuit spring) and PTC Dimensions L x W x H 110 x 22 x 72 mm 110 x 22 x 72 mm 110 x 22 x 72 mm Earthing (Grounding) by via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame via grounding bar and isolation unit on LSA backmount frame Enclosure material / colour Thermoplastic: grey or yellow Thermoplastic: grey or yellow Thermoplastic: grey or yellow 24 00 26 24 00 28 24 01 42 Order Data Article-No. Dimension drawing, see pages 220 to 223 148 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting LSA Connection Module Each module can hold 10 DA at the cable and allocation side for a permanent connection. LSA magazines filled with gas-filled surge arresters can be plugged in. The connection module is grey. Basic circuit diagram n Corresponds with IEC 60352-4 and DIN 41611-6 n Wiring with two wires of same diameter is possible Technical Data LSA 2/10-AN Withstand voltage 2 kV Volume resistance < 10 mΩ Conductor diameter, solid wire Insulation resistance External diameter of insulation n Amply dimensioned elastic arrangement of the wiring 0,4-0,8 AWG 26-20 mm Ris 5x 10.000 MΩ 0,7-1,5 mm Order Data Article-No. 24 01 00 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 149 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting LSA Disconnection Module Each module can hold 10 DA at the cable and allocation side. To be equipped with surge voltage protection connectors (coarse and fine protection) DP 1LSA or DP 10LSA. Applicable at the LPZ transition point 1-2 and higher. The disconnection module is white. Technical Data LSA 2/10-TR Withstand voltage 2 kV Volume resistance < 10 mΩ Insulation resistance Ris 5x 10.000 MΩ Conductor cross-section 0,4 -0,8 mm External diameter of insulation 0,7-1,5 mm Order Data Article-No. 24 01 02 Dimension drawing, see pages 220 to 223 150 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Surge protective devices for LSA mounting LSA Ground Module To connect 38 earthing connectors and shields. Order Data LSA 2/10-ER38-rot Article-No. 24 01 04 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 151 Surge protection for information technology and telecommunication Surge protective devices for LSA mounting Further LSA parts LSA 2/10 KSR (24 01 08) Hinged label holder for LSA 2/10 connection modules and surge voltage protection magazines. LSA DIN ADAPT (24 01 37) Hat rail adapter: Metal line with M5 screw thread (without screw) 152 LSA 2/10 AD (24 01 09) Magazine cover for protection against dust and unwanted contact. Transparent for visual inspection of the arresters in the magazine. LSA 2/10-ES (24 01 33) Pluggable grounding rail: For 10DA connection modules serving as a connection between LSA backmount frame and surge voltage protection connector. LSA 2/10-MW10-25/22 (24 01 10) LSA backmount frame 10x 10DA (modular), 25 mm grid / depth 22 mm, easily detachable upon individual requirement, available up to a size of 78 connection modules LSA 2/10 KS-120 (24 01 36) SA edge protection profile for backmount frame, 20 mm length Order Data LSA 2/10 KSR LSA 2/10 AD LSA 2/10-MW10-25/22 LSA DIN ADAPT Article-No. 24 01 08 24 01 09 24 01 10 24 01 37 Order Data LSA 2/10 KS-120 LSA 2/10-ES Article-No. 24 01 36 24 01 33 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for information technology and telecommunication Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 153 Everything for the protection of transmission and receiving systems Due to an expansion of its product range Leutron now offers devices that cover all established interfaces and frequency ranges. Transmitting and receiving systems with broadband and narrowband signals up to 6 GHz as well as base stations for mobile communications and broadcasting systems can be protected. The protective devices combine a very low protection level with an optimum transmission of the wanted signal. Special solutions for uncommon interfaces are available on request. Fault-free transmitting and receiving operation: 154 nProtective devices with gas-filled surge protectors, impedanceadjusted for frequency ranges up to 6 GHz – simultaneous transmission of a DC supply voltage possible n Protective devices for radio installations with narrowband signals with Lambda/4 Stubline technology. This results in a high damping of the interfering noise, whilst the wanted signal transmitted without disturbance is Surge protection for transmitting and receiving systems High-quality protective devices for base stations for mobile communications with high capacity of absorbing interference energy. Surge protection for transmitting and receiving systems Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 155 Aerial system protection through Lambda/4 Stubline Applications for different installation types: nGSM and UMTS installations nTri-band systems nTerrestrial trunked radio (TETRA) Versions for N and DIN 7/16 connectors High damping values Bandpass filter, adjusted to the application 156 Surge protection for transmitting and receiving systems Surge protection for coaxial interfaces Versions for different interfaces: nBNC connectors nFME connectors nSMA connectors nN connectors nDIN 7/16 connectors Protection for different voltage levels Versions up to 6 GHz available Mounting on mounting plate or as adapter plug/ socket Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 157 Surge protection for transmitting and receiving systems SPD for SAT/TV/Radio applications DataPro-SAT and Radio/TV Surge protection device for radio and television equipment for the use directly at the building entry. F n high performance antenna protection n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n equipped with GDT surge voltage protector n Easy installation Basic circuit diagram F n Test standard: IEC 61643-21 / EN 61643-21 Technical Data DataPro-SAT IEC category/EN type D1 / C2 / C1 / C3 DataPro-Radio/TV D1 / C2 / C1 / C3 Plug connector F connector (acc. to IEC 60169-24) TV/Radio connector (acc. to IEC 60169-2) Max. permissible rated direct voltage Uc 75 V 75 V Nominal current IN 4A 4A Iimp 2,5 kA 2,5 kA In 10 kA 10 kA Up 600 V 600 V ImpedanceZ 75 Ω 75 Ω Insertion loss fE 4 dB 4 dB Frequency range fO 0 - 2.150 MHz 0 - 862 MHz Response time tA ≤ 100 ns ≤100 ns Operating temperature range TU -40 - +80 °C -40 - +80 °C Degree of protection (IEC EN 60529) IP 20 IP 20 Installation dimensions (W × H × D) 40 x 44 x 22 mm 40 x 44 x 42 mm Mounting type wall mounting wall mounting 21 00 20 21 00 30 D1 lightning impulse current (10/350 µs) C2 nominal discharge current (8/20 µs) Protection level at 1kV/μs Order Data Article-No. Dimension drawing, see pages 220 to 223 158 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems SPD with BNC connector DataPro Koax-8V-BNC Lightning and surge protection for coaxial signal lines with BNC connector for the use at the building entry. FME BNC Basic circuit diagram n High performance surge protector n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n For video surveillance cameras n Connector according to IEC 61169-8 Technical Data DataPro Koax-8V-BNC IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 Plug connector BNC (m/f) BNC (m/f) Max. continuous operating voltage DC Uc Max. power DataPro Koax-8V-BNC-75 Ohm 8 V= 8 V= 0,7 W 0,7 W Series restistance (DC resistance) per line Z 10 Ω 10 Ω Surge impedance Z 50 Ω 75 Ω Response time fine protection tA ≤ 2 ns ≤ 2 ns In 5 kA 5 kA C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) Imax 10 kA 10 kA D1 lightning impulse current (10/350 µs) Iimp 1 kA 1 kA C2 protection level line-shield at ln Up ≤ 20 V ≤ 20 V C3 protection level line-shield at 1kV/μs Up ≤ 13 V ≤ 13 V C3 protection level line-shield-PE at 1kV/μs (Up) Up ≤ 600 V ≤ 600 V Frequency range fO Return loss Operating temperature range TU Degree of protection (IEC EN 60529) n Grounding via connected earthing wire 0.75 mm², L=ca.30 mm n Test standard: IEC 61643-21 / EN 61643-21 0 - 60 MHz 0 - 60 MHz at 40 kHZ: > 20 dB at 40 kHZ: > 20 dB - 25 - +85 °C -25 - +85 °C IP 20 IP 20 54 43 46 54 43 40 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 159 Surge protection for transmitting and receiving systems SPD with BNC connector DataPro Koax BNC Surge protection device for coaxial signal lines with BNC connectors and very high frequencies. The discharge current arrester can be mounted in and earthed in a mounting plate. Basic circuit diagram n Surge protection device for extremly high freqeuncies up to 6 GHz n Applicable at the boundaries LPZ 0B - 1 and higher n Connector according to IEC 61169-8 Technical Data DP Koax BNC 50Ohm IEC category/EN type C2 / C1 / C3 Plug connector BNC (m/f) Surge impedance Z Frequency range fO Return loss Max. impulse discharge current (8/20) 150 - 250 V In Imax Max. transmission capacity Operating temperature range Degree of protection (IEC EN 60529) 50 Ω 0 - 6000 MHz ≥ 20 dB Breakdown voltage (100V/s) C2 nominal discharge current (8/20 µs) n Earthing via metal housing n Test standard: IEC 61643-21 / EN 61643-21 5 kA 10 kA 25 W TU -40 - +85 °C IP 67 Order Data Article-No. 54 43 30 Dimension drawing, see pages 220 to 223 160 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems SPD with SMA connector AntPro 5,8GHz-SMA Surge protection device for coaxial signal lines with SMA connectors.The very high frequency range of up to 6 GHz enables the use in wireless LAN and similar applications.The discharge current arrester can be mounted in and earthed in a mounting plate. Basic circuit diagram n Surge protection device for extremly high freqeuncies up to 6 GHz n Applicable at the boundaries LPZ 0B - 1 and higher n Connector according to IEC 61169-8 n Earthing via metal housing Technical Data AntPro 5,8GHz-SMA AntPro 5,8GHz-R-SMA IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 Plug connector SMA (m/f) R-SMA (f/m) 50 Ω 50 Ω Surge impedance Z Frequency range fO Return loss Breakdown voltage (100V/s) C2 nominal discharge current (8/20 µs) Max. impulse discharge current (8/20) In Imax Max. transmission capacity Operating temperature range TU 0 - 6000 MHz 0 - 6000 MHz ≥ 20 dB ≥ 20 dB 150 - 250 V 150 - 250 V 5 kA 5 kA 10 kA 10 kA 25 W 25 W -40 - +85 °C -40 - +85 °C 04 58 00 04 58 02 n Test standard: IEC 61643-21 / EN 61643-21 n Mounting with angle bracket or in mounting plate possible n Second version with inverse polarity (inner conductor is socket instead of plug) Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 161 Surge protection for transmitting and receiving systems SPD with N connector AntPro Koax-GSM-N/230 AntPro Koax-GSM-N was designed for the coarse protection of highly sensitive electronical HF amplifiers, e.g., for GSM aerial systems with GSM aerial cable RG213/U (max. 180 W at max. 1 GHz, Ø 10.5 mm). Basic circuit diagram n High performance surge arrester for broadband applications with frequency ranges from DC up to 2.5 GHz. n Applicable at the boundaries LPZ 0B - 1 and higher Technical Data AntPro Koax-GSM-N/230 AntPro Koax-GSM-N-230(f/f) IEC category/EN type C2 / C1 / C3 C2 / C1 / C3 Plug connector N (m/f) N (f/f) Surge impedance Z Frequency range fO 50 Ω 50 Ω 0 - 2500 MHz 0 - 2500 MHz Return loss dBtyp.: 1GHz: 30 dB/2,5 GHz: 23 dBtyp.: 1GHz: 30 dB/2,5 GHz: 23 Insertion loss dBtyp.:1GHz<0,1dB/2,5 GHz<0,2 dBtyp.:1GHz<0,1dB/2,5 GHz<0,2 DC spark-over voltage 230 V 230 V C2 nominal discharge current (8/20 µs) In 15 kA 15 kA Max. impulse discharge current (8/20) Imax 20 kA 20 kA Insulation resistance Risol ≥ 5 GΩ ≥ 5 GΩ Vertical resistance inner conductor R ≤ 2 mΩ ≤ 2 mΩ Vertical resistance outer conductor R ≤ 0,5 mΩ ≤ 0,5 mΩ -30 - +100 °C -30 - +100 °C IP 67 IP 67 04 00 01 04 00 04 Operating temperature range Degree of protection (IEC EN 60529) TU n Connector according to IEC 61169-8 n Test standard: IEC 61643-21 / EN 61643-21 n The f/f version can be mounted in a mounting plate or with an angle bracket. Order Data Article-No. Dimension drawing, see pages 220 to 223 162 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems Lambda/4 stubline SPD with N connector AntPro Lambda/4 N Surge protective device in maintenance-free Lamba/4 style with band-pass filter characteristic. Therefore a very good transmission characteristic combined with high attenuation of the disturbances can be reached. Remote antenna power supply is not possible because of the short-circuit characteristic for low-frequency signals. Basic circuit diagram n High performance Lambda/4 Stubline for antenna protection without interruption of the useful signal n Suitable for TETRA and GSM installations n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n Connector according to IEC 61169-16 n Test standard: IEC 61643-21 / EN 61643-21 Technical Data AntPro Lambda/4 N 0.51GHz AntPro Lambda/4 N 0.8GHz IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 Plug connector N (m/f) N (m/f) N (m/f) Surge impedance Z Frequency range fO AntPro Lambda/4 N 2.0GHz 50 Ω 50 Ω 50 Ω 380 - 512 MHz 800 - 900 MHz 1700 - 2300 MHz Return loss < - 23 dB < - 23 dB < - 20,5 dB Insertion loss < 0,1 dB < 0,1 dB < 0,1 dB min. 50 kA min. 50 kA min. 50 kA Max. impulse discharge current (8/20) Imax Vertical resistance inner conductor R ≤ 1,5 mΩ ≤ 1,5 mΩ ≤ 1,5 mΩ Vertical resistance outer conductor R ≤ 1 mΩ ≤ 1 mΩ ≤ 1 mΩ TU Operating temperature range Degree of protection (IEC EN 60529) -30 - +100 °C -30 - +100 °C -30 - +100 °C IP 67 IP 67 IP 67 04 00 20 04 00 22 04 00 23 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 163 Surge protection for transmitting and receiving systems Lambda/4 stubline SPD with N connector AntPro Lambda/4 N (f/f) Surge protective device in maintenance-free Lamba/4 style with band-pass filter characteristic. Therefore a very good transmission characteristic combined with high attenuation of the disturbances can be reached. Remote antenna power supply is not possible because of the short-circuit characteristic for low-frequency signals. Basic circuit diagram n High performance Lambda/4 Stubline for antenna protection without interruption of the useful signal n Applicable at the building entry at the boudaries LPZ 0A-1 and higher Technical Data AntPro Lambda/4 N 0.51GHz (f/f) AntPro Lambda/4 N 2.0GHz (f/f) IEC category/EN type D1 / C2 / C1 / C3 D1 / C2 / C1 / C3 Plug connector N (f/f) N (f/f) Surge impedance Z Frequency range fO 50 Ω 50 Ω 380 - 512 MHz 1700 - 2300 MHz Return loss < - 23 dB < - 20,5 dB Insertion loss < 0,1 dB < 0,1 dB min. 50 kA min. 50 kA Max. impulse discharge current (8/20) Imax Vertical resistance inner conductor R ≤ 1,5 mΩ ≤ 1,5 mΩ Vertical resistance outer conductor R ≤ 1 mΩ ≤ 1 mΩ -30 - +100 °C -30 - +100 °C IP 67 IP 67 04 00 21 04 00 24 Operating temperature range Degree of protection (IEC EN 60529) n Suitable for TETRA and GSM installations n Connector according to IEC 61169-16 n Test standard: IEC 61643-21 / EN 61643-21 n Mounting with angle bracket or in mounting plate possible TU Order Data Article-No. Dimension drawing, see pages 220 to 223 164 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems SPD with DIN 7/16 connector DataPro Koax 7/16 DataPro Koax 7/16 was developed for the coarse protection of highly sensitive RF amplifiers with DIN 7/16 connectors such as amplifiers for GSM antenna systems. Basic circuit diagram n High performance surge arrester for broadband applications with frequency ranges from DC up to 2.5 GHz. n Applicable at the boundaries LPZ 0B - 1 and higher Technical Data DP Koax 7/16 IEC category/EN type C2 / C1 / C3 Plug connector DIN 7/16 (m/f) Surge impedance Z Frequency range fO n Connector according to IEC 61169-4 n Test standard: IEC 61643-21 / EN 61643-21 50 Ω 0 - 2500 MHz Return loss typ.: 1GHz - 32dB; 2GHz - 23dB; 2,2GHz - 23dB; 2,5GHz - 20dB; 2,7GHz - 17 dB Insertion loss typ.: 2,2GHz <0,1dB; 2,5GHz <0,2 dB DC spark-over voltage 230 V C2 nominal discharge current (8/20 µs) In 15 kA Max. impulse discharge current (8/20) Imax 20 kA Insulation resistance Risol Vertical resistance inner conductor Vertical resistance outer conductor ≤ 0,4 mΩ R ≤ 0,2 mΩ TU Operating temperature range Degree of protection (IEC EN 60529) ≥ 10 GΩ R -55 - +155 °C IP 67 Order Data Article-No. 10 10 00 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 165 Surge protection for transmitting and receiving systems SPD with DIN 7/16 connector DataPro Koax 7/16 (f/f) DataPro Koax 7/16 was developed for the coarse protection of highly sensitive RF amplifiers with DIN 7/16 connectors such as amplifiers for GSM antenna systems. Basic circuit diagram n High performance surge arrester for broadband applications with frequency ranges from DC up to 2.5 GHz. n Applicable at the boundaries LPZ 0B - 1 and higher Technical Data DP Koax 7/16 (f/f) IEC category/EN type C2 / C1 / C3 Plug connector DIN 7/16 (f/f) Surge impedance Z Frequency range fO n Connector according to IEC 61169-4 n Test standard: IEC 61643-21 / EN 61643-21 n Mounting with angle bracket or in mounting plate possible 50 Ω 0 - 2500 MHz Return loss typ.: 1GHz - 32dB; 2GHz - 23dB; 2,2GHz - 23dB; 2,5GHz - 20dB; 2,7GHz – 17 dB Insertion loss typ.: 2,2GHz <0,1dB; 2,5GHz <0,2 dB DC spark-over voltage 230 V C2 nominal discharge current (8/20 µs) In 15 kA Max. impulse discharge current (8/20) Imax 20 kA Insulation resistance Risol Vertical resistance inner conductor Vertical resistance outer conductor Operating temperature range Degree of protection (IEC EN 60529) ≥ 10 GΩ R ≤ 0,4 mΩ R ≤ 0,2 mΩ TU -55 - +155 °C IP 67 Order Data Article-No. 10 10 01 Dimension drawing, see pages 220 to 223 166 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems Lambda/4 stubline SPD with DIN 7/16 connector AntPro Lambda/4 7/16 TRI Surge protective device in maintenance-free Lamba/4 style with band-pass filter characteristic. Therefore a very good transmission characteristic combined with high attenuation of the disturbances can be reached. Remote antenna power supply is not possible because of the short-circuit characteristic for low-frequency signals. Basic circuit diagram n High performance Lambda/4 Stubline for antenna protection without interruption of the useful signal n Suitable for 800/900 MHz and 1800/1900 MHz-GSM and UMTS systems Technical Data n Connector according to IEC 61169-4 n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n Test standard: IEC 61643-21 / EN 61643-21 AntPro Lambda/4 7/16 TRI IEC category/EN type D1 / C2 / C1 / C3 Plug connector DIN 7/16 (m/f) Surge impedance Z Frequency range fO 50 Ω 806 - 960 / 1710 - 2200 MHz Return loss typ.: <-23dB / 806-859 MHz; <-27dB / 860-960 MHz; <-27dB / 1710-1990 MHz; <-23 dB / 2000-2200 MHz Insertion loss < 0,1 dB Max. impulse discharge current (8/20) Imax Max. transmission capacity min. 50 kA W≤ 1,8 kW / 1 GHz Vertical resistance inner conductor Vertical resistance outer conductor Operating temperature range R ≤ 0,4 mΩ R ≤ 0,2 mΩ TU Degree of protection (IEC EN 60529) -55 - +150 °C IP 67 Order Data Article-No. 04 00 30 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 167 Surge protection for transmitting and receiving systems Lambda/4 stubline SPD with DIN 7/16 connector AntPro Lambda/4 7/16 TRI (f/f) Surge protective device in maintenance-free Lamba/4 style with band-pass filter characteristic. Therefore a very good transmission characteristic combined with high attenuation of the disturbances can be reached. Remote antenna power supply is not possible because of the short-circuit characteristic for low-frequency signals. Basic circuit diagram n High performance Lambda/4 Stubline for antenna protection without interruption of the useful signal n Suitable for 800/900 MHz and 1800/1900 MHzGSM and UMTS systems n Connector according to IEC 61169-4 Technical Data n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n Test standard: IEC 61643-21 / EN 61643-21 n Mounting with angle bracket or in mounting plate possible AntPro Lambda/4 7/16 TRI (f/f) IEC category/EN type D1 / C2 / C1 / C3 Plug connector DIN 7/16 (f/f) Surge impedance Z Frequency range fO 50 Ω 806 - 960 / 1710 - 2200 MHz Return loss typ.: <-23 dB / 806-859 MHz; <-27 dB / 860-960 MHz; <-27dB / 1710-1990 MHz; <-23 dB / 2000-2200 MHz Insertion loss < 0,1 dB Max. impulse discharge current (8/20) Imax Max. transmission capacity Vertical resistance inner conductor Vertical resistance outer conductor Operating temperature range Degree of protection (IEC EN 60529) min. 50 kA W≤ 1,8 kW / 1 GHz R ≤ 0,4 mΩ R ≤ 0,2 mΩ TU -55 - +150 °C IP 67 Order Data Article-No. 04 00 31 Dimension drawing, see pages 220 to 223 168 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems Lambda/4 stubline SPD with DIN 7/16 connector AntPro -7/16 Surge protective device in maintenance-free Lamba/4 style with band-pass filter characteristic. Therefore a very good transmission characteristic combined with high attenuation of the disturbances can be reached. Remote antenna power supply is not possible because of the short-circuit characteristic for low-frequency signals. Basic circuit diagram n High performance Lambda/4 Stubline for antenna protection without interruption of the useful signal n Suitable for TETRA installations (380 - 470 MHz) Technical Data n Applicable at the building entry at the boudaries LPZ 0A-1 and higher n Connector according to IEC 61169-4 n Test standard: IEC 61643-21 / EN 61643-21 AntPro Lambda 7/16 0.42GHz IEC category/EN type D1 / C2 / C1 / C3 Plug connector DIN 7/16 (f/f) Surge impedance Z Frequency range fO Return loss 50 Ω 380 - 512 MHz < -23 dB Insertion loss fE < 0,1 dB Max. impulse discharge current (8/20) Imax min. 50 kA Max. power transfer Pmax 5000 W Vertical resistance inner conductor R ≤ 0,4 mΩ Vertical resistance outer conductor R ≤ 0,2 mΩ Operating temperature range TU Degree of protection (IEC EN 60529) -55 - +150 °C IP 67 Order Data Article-No. 04 04 25 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 169 Surge protection for transmitting and receiving systems SPD with FME connector DataPro FME-AD Surge voltage protection for sensitive GSM modems with FME antenna connector.The set contains an dischrage current arrester with SMA connector and a freqeuncy range up to 6 GHz and adapters for FME connectors. Basic circuit diagram n High performance surge arrester for broadband applications with frequency ranges from DC up to 2 GHz. n Applicable at the boundaries LPZ 0B - 1 and higher Technical Data DP FME-AD IEC category/EN type C2 / C1 / C3 Plug connector FME (m/m) Surge impedance Z Frequency range fO Return loss Max. impulse discharge current (8/20) 150 - 250 V In Imax Max. transmission capacity Operating temperature range 50 Ω 0 - 2000 MHz ≥ 20 dB Breakdown voltage (100V/s) C2 nominal discharge current (8/20 µs) n Test standard: IEC 61643-21 / EN 61643-21 n Mounting with angle bracket or in mounting plate possible 5 kA 10 kA 25 W TU -40 - +80 °C Order Data Article-No. 16 05 20 Dimension drawing, see pages 220 to 223 170 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Surge protection for transmitting and receiving systems Notes Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 171 Filter with integrated surge protection For protection against overvoltages and harmonics Leutron offers EMC filters which are combined with a surge protection. These devices suppress harmonics and transient surges, hence, allowing equipment to operate smoothly even in high-interference environments. With the enhancement of its product range Leutron now offers protective devices for the area of measuring systems and automatic control, thus covering the complete field of industrial applications. Leutron guarantees reliable signals due to EMC filters. EMC filters combined with harmonized surge protection: 172 nProtection against transient overvoltages and harmonics nLeakage-current free nLow residual voltages mean reduced stress for the system to be protected nOutstanding differential-mode and common-mode damping of the filters EMC filters with Integrated surge protection The EMC filters convince with their compact construction and the optimally harmonised protection components filter and surge protection. EMC filters with integrated surge protection Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 173 Filters with integrated surge protection up to 200 A Robust and shielded design Versions up to a nominal current of 200 A available For one phase and three phase mains supplies 174 Harmonics filter, combined with surge protection EMC filters with Integrated surge protection Filters with integrated surge protection for measuring and control equipment Integrated surge protection Low-pass filter with threshold frequency of 30 to 600 kHz Mounting on DIN rail For two or three single wires Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 175 EMC filter with integrated surge protection Line filter up to 200A EnerPro Filter for mounting rail For overvoltage protection at single-pole TN systems with very sensitive electronical devices. Suitable for the application in single-phase TN Systems. The new protective circuit with filter contains an optimal decoupling between its coarse protection (varistors) and its fine protection (varistors). Basic circuit diagram n Applicable at the boundaries LPZ 0B - 2 and higher n All leakage current-afflicted elements are galvanically isolated from earth by a gas-filled surge arrester (GDT). Technical Data EPF 230V/16A-Tr EPF 230V/25A-Tr IEC category/EN type Type 2 + 3 / class II + III Type 2 + 3 / class II + III UN 230 V~ 230 V~ Nominal alternating voltage Max. continous operating voltage AC Uc 275 V~ 275 V~ Protection level at 5 kA (8/20 µs) Up ≤ 1,4 kV ≤ 1,4 kV Protection level at In (8/20 µs) Up ≤ 2 kV ≤ 2 kV Response time L-N/L,N-PE Nominal impulse discharge current (10 x 8/20) Max. impulse discharge current (1x 8/20 µs) In Imax Max. acceptable fuse or back-up fuse Operating temperature range TU ≤ 25 ns ≤ 25 ns 15 kA 15 kA 25 kA 25 kA 16 A gL/gG 25 A gL/gG -40 - +80 °C -40 - +80 °C Max. conductor cross section 50mm² stranded/35mm² fexible 50mm² stranded/35mm² fexible Recommended conductor cross section 25 mm² 25 mm² Max. connection torque for terminals 4,5 Nm 4,5 Nm Enclosure material / colour polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 Mounting on 35 mm DIN rail (DIN EN 50 022) 35 mm DIN rail (DIN EN 50 022) Installation dimensions (W × H × D) 88 x 107 x 67 mm 88 x 107 x 67 mm 25 30 16 25 30 17 n Test standard: IEC 61643-1 / EN 61643-11 IP 20 Order Data Article-No. Dimension drawing, see pages 220 to 223 176 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection Line filter up to 200A EnerPro Filter up to 35 A, two-pole For overvoltage protection at single-pole TN systems with very sensitive electronical devices. Suitable for the application in single-phase TN systems. n Test standard: IEC 61643-1 / EN 61643-11 n Maximum impulse discharge current of 20 kA (8/20µs) Basic circuit diagram n Applicable at the boundaries LPZ 0B - 2 and higher n The low-pass filter eliminates high-frequency electromagnetic interferences caused by lightning or switching actions in the network. Technical Data EPF 60V/16A-S EPF 48V/25A-S EPF 230V/16A-S EPF 230V/35A-S IEC category/EN type Type 2 + 3 / class II + III Type 2 + 3 / class II + III Type 2 + 3 / class II + III Type 2 + 3 / class II + III 60 V= 48 V= - V= - V= Nominal direct voltage UN Max. continuous operating voltage DC Uc 70 V= 70 V= - V= - V= Nominal alternating voltage UN 42 V~ 42 V~ 230 V~ 230 V~ Max. continous operating voltage AC Uc 50 V~ 50 V~ 275 V~ 275 V~ Voltage protection level (1kV/μs) Up ≤ 1,5 kV ≤ 1,0 kV ≤ 1,4 kV ≤ 1,4 kV Protection level at In (8/20 µs); worst case Up ≤ 2,5 kV ≤ 1,5 kV ≤ 2 kV ≤ 2 kV Response time L-N/L,N-PE Nominal discharge current (8/20) Max. impulse discharge current (8/20) In Imax Max. acceptable fuse or back-up fuse Operating temperature range TU ≤ 25 ns ≤ 25 ns ≤ 25 ns ≤ 25 ns 15 kA 15 kA 15 kA 15 kA 20 kA 20 kA 20 kA 20 kA 16 A gL/gG 25 A gL/gG 16 A gL/gG 35 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C -40 - +80 °C Max. conductor cross section 4 mm² 4 mm² solid. 10/ flexible. 6 mm² solid. 10/ flexible. 6 mm² Recommended conductor cross section 2,5 mm² 2,5 mm² Enclosure material / colour aluminium / silver aluminium / silver aluminium / silver aluminium / silver Dimensions L x W x H 211 x 71 x 106 mm 211 x 71 x 106 mm 211 x 71 x 106 mm 211 x 71 x 106 mm Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 25 30 22 25 30 53 25 30 20 25 30 85 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 177 EMC filter with integrated surge protection Line filter up to 200A Technical Data EPF 230V/16A-W IEC category/EN type Type 2 + 3 / class II + III Nominal direct voltage UN - V= Max. continuous operating voltage DC Uc - V= Nominal alternating voltage UN 230 / 400 V~ Max. continous operating voltage AC Uc 275 / 480 V~ Voltage protection level at 5kA (8/20µs) or 1kV/µs Up ≤ 1,4 kV Protection level at In (8/20 µs) Up ≤ 2 kV Response time L-N/L,N-PE Nominal discharge current (8/20) Max. impulse discharge current (8/20) ≤ 25 ns In Imax Max. acceptable back-up fuse or circuit-breaker (MCB) Operating temperature range 15 kA 20 kA 16 A gL/gG TU -40 - +80 °C Max. conductor cross section solid. 10/ flexible. 6 mm² Enclosure material / colour Aluminium / silver Dimensions L x W x H 211 x 106 x 72 mm Degree of protection (IEC EN 60529) IP 20 Mounting on Mounting plate Order Data Article-No. 178 25 30 25 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection Line filter up to 200A EnerPro Filter up to 35 A, four-pole For overvoltage protection at single-pole TN systems with very sensitive electronical devices. Suitable for the application in three-phase 230/400 V TN systems. Basic circuit diagram n Applicable at the boundaries LPZ 0B - 2 and higher n Leakage current-free n Test standard: IEC 61643-1 / EN 61643-11 n Protects foundation earthing electrode against AC-caused corrosion n To protect the supply of sensible equipment and installations n Maximum impulse discharge current of 20 kA (8/20µs) Technical Data EPF 230/400V/16A-W EPF 230/400V/25A-W EPF 230/400V/35A-W IEC category/EN type Type 2 + 3 / class II + III Type 2 + 3 / class II + III Type 2 + 3 / class II + III 230 / 400 V~ 230 / 400 V~ 230 / 400 V~ Nominal alternating voltage UN Max. continous operating voltage AC Uc 275 / 480 V~ 480 V~ 275 / 480 V~ Voltage protection level at 5kA (8/20µs) or 1kV/µs Up ≤ 1,4 kV ≤ 1,4 kV ≤ 1,4 kV Protection level at In (8/20 µs); worst case Up Response time L-N/L,N-PE Response time tA Nominal discharge current (8/20) Max. impulse discharge current (8/20) ≤ 2 kV ≤ 2 kV ≤ 25 ns ≤ 25 ns < 25 ns < 25 ns < 25 ns In 15 kA 15 kA 15 kA Imax 20 kA 25 kA 20 kA Max. acceptable back-up fuse or circuit-breaker (MCB) Operating temperature range ≤ 2 kV ≤ 25/ ≤ 50 ns TU 16 A gL/gG 25 A gL/gG 35 gL / gG A -40 - +80 °C -40 - +80 °C -40 - +80 °C Max. conductor cross section solid. 10/ flexible. 6 mm² solid. 10/ flexible. 6 mm² solid. 10/ flexible. 6 mm² Dimensions L x W x H 209 x 106 x 71 mm 211 x 106 x 72 mm 209 x 106 x 71 mm Enclosure material / colour Aluminium / silver Aluminium / silver Aluminium / silver Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Mounting on mounting plate Mounting plate Mounting plate 25 30 45 25 30 80 25 31 00 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 179 EMC filter with integrated surge protection Line filter up to 200A EnerPro Filter up to 200 A, 4-pole For overvoltage protection at single-pole TN systems with very sensitive electronical devices. Suitable for the application in three-phase 230/400 V TN systems. Basic circuit diagram n Applicable at the boundaries LPZ 0B - 2 and higher n 4-pole n Leakage current-free n Test standard: IEC 61643-1 / EN 61643-11 n Protects foundation earthing electrode against AC-caused corrosion n To protect the supply of sensible equipment and installations Technical Data EPF 230/400V/63A-E EPF 230/400V/100A-E EPF 230/400V/200A-E IEC category/EN type Type 2 + 3 / class II + III Type 2 + 3 / class II + III Type 2 + 3 / class II + III UN 230 / 400 V~ 230 / 400 V~ 230 / 400 V~ Max. continous operating voltage AC Uc 275 / 480 V~ 275 / 480 V~ 275 / 480 V~ Voltage protection level at 5kA (8/20µs) or 1kV/µs Up ≤ 1,4 kV ≤ 1,4 kV ≤ 1,4 kV Protection level at In (8/20 µs); worst case Up ≤ 2 kV ≤ 2 kV ≤ 2 kV ≤ 25 ns ≤ 25 ns ≤ 25 ns 15 kA 15 kA 15 kA Nominal alternating voltage Response time L-N/L,N-PE Nominal discharge current (8/20) Max. impulse discharge current (8/20) In Imax 25 kA 25 kA 25 kA 63 A gL/gG 100 A gL/gG 200 A gL/gG -40 - +80 °C -40 - +80 °C -40 - +80 °C Max. conductor cross section solid 25-95/flexible. 35-95 mm² solid 25-95/flexible. 35-95 mm² solid 25-95/flexible. 35-95 mm² Max. connection torque for terminals 4,5 Nm 4,5 Nm 4,5 Nm Dimensions L x W x H 240 x 106 x 110 mm 420 x 380 x 170 mm 420 x 380 x 170 mm Enclosure material / colour Aluminium / silver Aluminium / silver Aluminium / silver Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 Mounting on Mounting plate Mounting plate Mounting plate 25 31 30 25 31 40 25 31 60 Max. acceptable back-up fuse or circuit-breaker (MCB) Operating temperature range TU Order Data Article-No. Dimension drawing, see pages 220 to 223 180 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection MCR technology with integrated low-pass filter MCR Technology with integrated low-pass filter Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 181 EMC filter with integrated surge protection MCR technology with integrated low-pass filter IsoProData 150V/150V-Tr EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment. Basic circuit diagram 1 1p 2 n Signal and data line protection with low-pass filter n Protective circuit for 2 signal lines without reference to ground potential n Lightning current 5 kA (10/350 µs) per wire n Applicable at the boundaries LPZ 0A - 2 and higher 2p Technical Data IsoProData 150V/150V-Tr IEC category/EN type C1 / C2 / C3 / D1 Nominal direct voltage UN 150 V= Max. continuous operating voltage DC Uc 160 V= Max. continous operating voltage AC Uc 112 V~ Nominal current IN 1,5 A Leakage current at Uc DC IL ≤ 5 µA Series restistance (DC resistance) per line Z 0,3 Ω Series inductance, typ. (L) 130 µH Response time tA ≤ 2 ns C2 nominal discharge current (8/20 µs) In 20 kA D1 lightning impulse current (10/350 µs) in total Itotal 10 kA D1 lightning impulse current (10/350 μs) per wire Iimp 5 kA Protection level, residual voltage line-earth at In resp. 1 kV/µs Up ≤ 250 V Capacitance, line-earth C <1 nF Max. operating frequency (< 3 dB) fG 600 kHz Operating temperature range TU -25 - +85 °C Max. conductor cross section n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Space required for installation: 17.5 mm 16 mm² massiv or 6 mm² Litze with wirecap Order Data Article-No. 27 03 03 Dimension drawing, see pages 220 to 223 182 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro2x1 for DIN rail EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment. Basic circuit diagram 1 1p 2 n Signal and data line protection with low-pass filter n Protective circuit for 2 signal lines with common ground n Maximum nominal current 500 mA n Applicable at the boundaries LPZ 0B - 2 and higher 2p n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Space required for installation: 17.5 mm Technische Daten DP2x1-6V/6V-Tr DP2x1-12V/12V-Tr DP2x1-15V/15V-Tr DP2x1-24V/24V-Tr IEC-Prüfklasse/EN-Type C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 NenngleichspannungUN 6 V= 12 V= 15 V= 24 V= Höchste Dauerspannung DC Uc 7 V= 13,6 V= 17 V= 28 V= Höchste Dauerspannung AC Uc 5 V~ 10 V~ 12 V~ 20 V~ NennstromIN 0,5 A 0,5 A 0,5 A 0,5 A C2 Nennableitstoßstrom (8/20) gesamt In 20 kA 20 kA 20 kA 20 kA C2 Nennableitstoßstrom (8/20) pro Ader In 10 kA 10 kA 10 kA 10 kA Up ≤9V ≤ 18 V ≤ 23 V ≤ 36 V Leckstrom bei Umax IL ≤ 5 µA ≤ 5 µA ≤ 5 µA ≤ 5 µA Grenzfrequenz (< 3 dB) fG Schutzpegel bei In (Ader-Erde) GleichstromwiderstandR 600 kHz 600 kHz 600 kHz 600 kHz 4,6 Ω 4,6 Ω 4.6 Ω 4.6 Ω Längsinduktivität, typ. (L) 28 µH 28 µH 28 µH 28 µH AnsprechzeittA ≤ 2 ns ≤ 2 ns ≤2 ns ≤ 2 ns Kapazität Ader-Erde 4 nF <2,3 nF ≤ 1.5 nF ≤ 1.3 nF BetriebstemperaturbereichTU C -25 - +85 °C -25 - +85 °C -25 - +85 °C -25 - +85 °C Max. Anschlussdrahtquerschnitt 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² Gehäusematerial/Farbe polycarbonate (halogen-free) UL 94-V0 / yellow polycarbonate (halogen-free) UL 94-V0 / yellow polycarbonate (halogen-free) UL 94-V0 / yellow polycarbonate (halogen-free) UL 94-V0 / yellow 27 06 06 27 12 12 27 15 15 27 24 24 Bestelldaten Artikel-Nr. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 183 EMC filter with integrated surge protection MCR technology with integrated low-pass filter Technical Data DP2x1-30V/30V-Tr DP2x1-36V/36V-Tr DP2x1-48V/48V-Tr DP2x1-60V/60V-Tr IEC category/EN type C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 30 V= 36 V= 48 V= 60 V= Nominal direct voltage UN Max. continuous operating voltage DC Uc 33 V= 40 V= 53 V= 64 V= Max. continous operating voltage AC Uc 22 V~ 29 V~ 37 V~ 45 V~ Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA ≤ 55 V ≤ 72 V ≤ 90 V Up ≤ 45 V Leakage current at Umax. IL ≤ 5 µA Max. operating frequency (< 3 dB) fG 600 kHz 600 kHz 600 kHz 600 kHz DC resistance R 4.6 Ω 4.6 Ω 4.6 Ω 4.6 Ω 28 µH 28 µH 28 µH 28 µH tA ≤ 2 ns Protection level at In (line-earth) Series inductance, typ. (L) Response time Capacitance, line-earth ≤ 1 nF ≤ 1 nF ≤ 0.8 nF ≤ 0.7 nF -25 - +85 °C -25 - +85 °C -25 - +85 °C -25 - +85 °C Max. conductor cross section 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² Enclosure material / colour Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Article-No. 27 30 30 27 36 36 27 48 48 27 60 60 Technical Data DP2x1-80V/80V-Tr DP2x1-150V/150V-Tr IEC category/EN type C1 / C2 / C3 C1 / C2 / C3 Operating temperature range C TU Order Data Nominal direct voltage UN 80 V= 150 V= Max. continuous operating voltage DC Uc 85 V= 160 V= Max. continous operating voltage AC Uc 60 V~ 112 V~ Nominal current IN 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA Up ≤ 140 V ≤ 250 V Leakage current at Uc DC IL ≤ 5 µA Max. operating frequency (< 3 dB) fG 600 kHz 600 kHz DC resistance R 4,6 Ω 4.4 Ω ≤ 28 µH 28 µH ≤ 1 nF ≤ 1 nF -25 - +85 °C -25 - +85 °C Max. conductor cross section 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² Enclosure material / colour Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 IP 20 27 80 80 27 04 04 Protection level at In (line-earth) Series inductance, typ. (L) Capacitance, line-earth Operating temperature range C TU Bestelldaten Article-No. 184 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro3x1 for DIN rail Basic circuit diagram EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment. 1 1p 2 2p n Signal and data line protection with low-pass filter n Protective circuit for 3 signal lines with common ground n Maximum nominal current 500 mA n Applicable at the boundaries LPZ 0B - 2 and higher p n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Space required for installation: 17.5 mm Technical Data DP3x1-12V/12V-Tr DP3x1-15V/15V-Tr DP3x1-24V/24V-Tr DP3x1-30V/30V-Tr IEC category/EN type C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 12 V= 15 V= 24 V= 30 V= Nominal direct voltage UN Max. continuous operating voltage DC Uc 13,6 V= 17 V= 28 V= 33 V= Max. continous operating voltage AC Uc 12 V~ 12 V~ 20 V~ 22 V~ Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 10 kA Up ≤ 18 V ≤ 23 V ≤ 36 V ≤ 45 V Leakage current at Umax DC IL ≤ 5 µA ≤ 5 µA ≤ 5 µA ≤ 5 µA Max. operating frequency (< 3 dB) fG 600 kHz 600 kHz 600 kHz 600 kHz DC resistance R 4.6 Ω 4.6 Ω 4.6 Ω 4.6 Ω 28 µH 28 µH 28 µH 28 µH C ≤ 2.3 nF ≤ 1,5 nF ≤ 1.3 nF ≤ 1 nF Protection level at In (line-earth) Series inductance, typ. (L) Capacitance, line-earth Operating temperature range TU -25 - +85 °C -25 - +85 °C -25 - +85 °C -25 - +85 °C Max. conductor cross section 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² 2,5 massiv or 1,5 Litze with wircap mm² Enclosure material / colour Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 28 12 12 28 15 15 28 24 24 28 30 30 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 185 EMC filter with integrated surge protection MCR technology with integrated low-pass filter Technical Data DP3x1-36V/36V-Tr DP3x1-48V/48V-Tr DP3x1-60/60V-Tr DP3x1-150V/150V-Tr IEC category/EN type C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 C1 / C2 / C3 Nominal direct voltage UN 36 V= 48 V= 60 V= 150 V= Max. continuous operating voltage DC Uc 40 V= 53 V= 64 V= 160 V= Max. continous operating voltage AC Uc 29 V~ 37 V~ 45 V~ 112 V~ Nominal current IN 0,5 A 0,5 A 0,5 A 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 20 kA 20 kA 20 kA 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA 10 kA 10 kA 20 kA Up ≤ 55 V ≤ 72 V ≤ 90 V ≤ 250 V Protection level at In (line-earth) Leakage current at Umax DC IL ≤ 5 µA ≤ 5 µA ≤ 5 µA ≤ 5 µA Max. operating frequency (< 3 dB) fG 600 kHz 600 kHz 600 kHz 600 kHz DC resistance R Series inductance, typ. (L) 4.6 Ω 4.6 Ω 4.4 Ω 28 µH 28 µH 28 µH ≤ 1 nF ≤ 0.8 nF ≤ 0.7 nF ≤ 1 nF -25 - +85 °C -25 - +85 °C -25 - +85 °C -25 - +85 °C Conductor cross section 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve Enclosure material / colour Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Polycarbonate (halogen-free) UL 94-V0 / yellow Degree of protection (IEC EN 60529) IP 20 IP 20 IP 20 IP 20 28 36 36 28 48 48 28 60 60 28 04 04 Capacitance, line-earth Operating temperature range C 4.6 Ω 28 µH TU Order Data Article-No. 186 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro2x1 0,3Ohm-Tr EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment.Lightning current and surge voltage protection for particularly long signal and bus lines. Thanks to the extremely low volume resistance (impedance only 0.3Ω) no noteworthy signal losses occur. It is a combined arrester to protect two single wires. Applicable at the LPZ transition point 0A-1 and higher. Basic circuit diagram 1 1p 2 n Signal and data line protection with low-pass filter n Very low volume resistance n Protective circuit for 2 signal lines with common ground n Maximum operating current 1.5 A 2p n Applicable at the boundaries LPZ 0A - 2 and higher n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Space required for installation: 17.5 mm Technical Data DP 2x1-12V/12V-0,3Ω -Tr DP 2x1-24V/24V-0,3Ω -Tr DP 2x1-30V/30V-0,3Ω-Tr DP 2x1-36V/36V-0,3Ω -Tr IEC category/EN type C1 / C2 / C3 / D1 C1 / C2 / C3 / D1 C1 / C2 / C3 / D1 C1 / C2 / C3 / D1 12 V= 24 V= 30 V= 36 V= Nominal direct voltage UN Max. continuous operating voltage DC Uc 28 V= 33 V= 35 V= 40 V= Max. continous operating voltage AC Uc 20 V~ 22 V~ 25 V~ 29 V~ Nominal current IN 1,5 A 1,5 A 1,5 A 1,5 A Series restistance (DC resistance) per line Z 0,3 Ω 0,3 Ω 0,3 Ω 0,3 Ω 28 µH 28 µH 28 µH 28 µH Series inductance, typ. (L) Response time fine protection tA ≤ 2 ns ≤ 2 ns ≤ 2 ns ≤ 2 ns C2 nominal discharge current (8/20 µs) In 10 kA 10 kA 10 kA 10 kA D1 lightning impulse current (10/350 µs) in total Itotal 5 kA 5 kA 5 kA 5 kA D1 lightning impulse current (10/350 μs) per wire Iimp 2,5 kA 2,5 kA 2,5 kA 2,5 kA ≤ 18 V ≤ 36 V ≤ 42 V ≤ 55 V Protection level, residual voltage line-earth at In resp. 1 kV/µs Up Capacitance, line-earth C ≤ 2,3 nF ≤ 1,3 nF ≤ 1,1 nF ≤ 1 nF Max. operating frequency (< 3 dB) fG <600 kHz < 600 kHz < 600 kHz <600 kHz Insulation resistance Operating temperature range Type of connection Risol TU >10 GΩ > 10 GΩ > 10 GΩ >10 GΩ -25 - +85 °C -25 - +85 °C -25 - +85 °C -25 - +85 °C 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve 2.5 mm² flexible with sleeve 26 12 12 26 24 24 26 30 30 26 36 36 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 187 EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro2x1-RLC/50V-Tr For overvoltage protection at single-pole TN systems with very sensitive electronical devices. Surge voltage protector for electronical equipment with an operating voltage of up to 50 V DC, with an impulse current withstand strength of 20 kA (8/20µs). The devices was designed to protect sensitive electronic equipment. Basic circuit diagram n Signal and data line protection with low-pass filter n Protective circuit for 2 signal lines without reference to ground potential n Maximum nominal current 100 mA Technical Data n Applicable at the boundaries LPZ 0B - 2 and higher n Mounting on 35 mm DIN rail n Space required for installation: 17.5 mm (1 TE) DP 2x1-RLC/50V-Tr IEC category/EN type C1 / C2 / C3 Max. continuous operating voltage DC Uc 50 V= Nominal current IN 0,1 A C2 nominal discharge current (8/20 µs) total (In) In 20 kA C2 nominal discharge current (8/20 µs) per line In 10 kA Protection level at 1 kV/µs (1p-2p) Up ≤ 60 V Protection level at 1 kV/µs (1p,2p-PE) Up ≤ 650 V Response time 1p-2p, 2-PE (bei 1 kV/µs) tA ≤ 2/25 ns Operating temperature range TU -25- +85 °C Max. conductor cross section 2.5 mm² flexible with sleeve Enclosure material / colour Polycarbonate (halogen-free) UL 94-V0 / yellow Protection circuit casting compound Polyurethan, flexibel Degree of protection (IEC EN 60529) IP 20 Dimension (DIN 43880) 1 TE (17.5 mm) Order Data Article-No. 28 70 50 Dimension drawing, see pages 220 to 223 188 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro2x1-RLC-Tr EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment. 1p 2 2p Basic circuit diagram protected side unprotected side 1 n Signal and data line protection with low-pass filter n Operating voltage up to 150 V DC n Protective circuit for 2 signal lines with common ground n Maximum nominal current 500 mA Technische Daten DP 2x1-RLC-Tr IEC-Prüfklasse/EN-Type C1 / C2 / C3 NenngleichspannungUN 150 V= Höchste Dauerspannung DC Uc 170 V= Höchste Dauerspannung AC Uc 120 V~ NennstromIN 0,5 A C2 Nennableitstoßstrom (8/20) gesamt In 20 kA C2 Nennableitstoßstrom (8/20) pro Ader In 10 kA Leckstrom bei Umax DC IL ≤ 0,001 µA Grenzfrequenz (< 3 dB) fG 100 kHz GleichstromwiderstandR 4,3 Ω Längsinduktivität, typ. (L) 185 µH Kapazität Ader-Erde C Schutzniveau Ader-Erde bei 1kV/µs und In n Nominal impulse discharge current 20 kA (8/20µs) n Mounting on 35 mm DIN rail n Degree of protection according to IEC EN 60529: IP 20 n Space required for installation: 17.5 mm ≤ 2,2 nF ≤ 800 V BetriebstemperaturbereichTU -25 - +85 °C Max. Anschlussdrahtquerschnitt 2.5 mm² flexible with sleeve Einbaumaße (DIN 43880) 1 TE (17.5 mm) Bestelldaten Artikel-Nr. 27 00 00 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 189 EMC filter with integrated surge protection MCR technology with integrated low-pass filter DataPro2-2MB-Tr EMC filter for data and signal lines combined with surge protection enables smooth operation of sensitive electronic equipment in rough environment. L1 Basic circuit diagram 1 2 1P n Signal and data line protection with low-pass filter n Applicable for transmission rates of 2 MBit/s (ISDN, PCM) n Maximum nominal current 500 mA 2P L2 Technical Data DP2-2MB-Tr IEC category/EN type C1 / C2 / C3 Nominal direct voltage UN 150 V= Max. continuous operating voltage DC Uc 170 V= Max. continous operating voltage AC Uc 120 V~ Nominal current IN 0,5 A C2 nominal discharge current (8/20 µs) total (In) In 10 kA C2 nominal discharge current (8/20 µs) per line In 5 kA Protection level line-earth at 1 kV/µs Up ≤ 600 V Max. frequency fG 8 MHz Operating temperature range TU -25 - +85 °C DC resistance per path n Applicable at the boundaries LPZ 0B - 2 and higher n Mounting on 35 mm DIN rail n Space required for installation: 17.5 mm (1 TE) R 0,5 Ω Signal tranismission rate bis 2 Mbit/s Conductor cross section 2.5 mm² flexible with sleeve Dimension (DIN 43880) 1 TE Order Data Article-No. 24 00 17 Dimension drawing, see pages 220 to 223 190 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de EMC filter with integrated surge protection Notes Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 191 Smooth operation guaranteed The measuring and testing devices are applied to check the sparkover voltage of lightning or surge protectors. These periodical tests of the protective function are demanded by the standards to ensure a steady and error-free operation. Down-time caused by overload of the surge protection can be eliminated by periodical reviews – with measuring and testing devices from Leutron. Tested for safety – manually or automatically: 192 n Manual measurement with the arrester tester, the varistor tester or the combined tester n F ully automatic measurement with the portable test equipment for SSCT magazines nA vailable adaptors for all types of gas-filled surge protectors monitoring Due to their robust design Leutron's measuring and testing devices are perfectly suited for regular mobile use. monitoring Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 193 Portable test equipment for SSCT (LSA) magazines Variable adapters for different types of magazines PC interface for remote control and data archiving Robust and mobile set-up in an easy to handle aluminium case 194 Fully automated test of SSCT (LSA) magazines for overvoltage protection monitoring kombitester Combined tester nTo test the sparkover voltage of lightning or surge protectors, e.g. MOV and gas discharge tubes Shipment in robust carrying case Combined tester for gas discharge tubes, isolating spark gaps and varistors with a sparkover voltage of up to 1,100 V Various adapters and measuring leads available Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 195 Monitoring Universal function tester for GDT, MOV and diodes as well as mixed circuits H65 For the testing of spark over voltage of lightning and surge voltage arresters, e.g. metal oxide varistors (MOV) and gas-filled surge arrester (GDT) or individually MOV and GDT. It is a mobile, easy-tohandle and microprocessor operated digital meter with a large LCD display for maintenance. n Digital measuring instrument with large LCD display n 9V battery operation or net work power unit n Measuring adapter (optional) for all popular GDTs Technical Data H65 Voltage measurement range 40 - 1100 V Test current 0,8 - 1,11 mA Display division 1V Rate-of-Rise (voltage) 1000 V/s Battery 9 V IEC 22 (compound battery) External AC/DC adapter 8 - 11 V DC / 200mA Typical current consumption display ca. 1 mA Typical current consumption during measuring activity Operating temperature range n Automatic fixing of indicated value n Scope of delivery includes: 1 carrying case, 1 test leads (2 pieces 1m each), 2 test terminals, 1 external power supply 230V 20 - 200 mA TU -10 - +35 °C Dimensions L x W x H 180 x 90 x 30 mm Enclosure material / colour self-extinguishing plastic / Black Order Data Article-No. 196 87 01 50 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Monitoring Function tester for GDT and GDT based spark-gaps H35 For the testing of spark over voltage of lightning and surge voltage arresters based on expulsiontype spark gap. Mobile, easy-to-handle digital meter with a large LCD display for maintenance. n Digital measuring instrument with large LCD display n 9V battery operation or net work power unit n Measuring adapter (optional) for all popular GDTs Technical Data H35 Measured value display LCD, digital, 3,5 stellig in V Measuring range 40 - 1000 V Max. testing voltage 1200 V Test current 0,1 mA Testing period min. 1s up to measuring value is seen Display division 1V Rate-of-Rise (voltage) 20 Battery 9V IEC 22 (compound battery) Test terminals (4mm banana jack) Minuspol: black / Pluspol: red External AC/DC adapter 8 - 11 V DC/300mA Typical current consumption in stand-by position 0,2 mA Typical current consumption during measuring activity Operating temperature range n Automatic fixing of indicated value n Scope of delivery includes: 1 carrying case, 1 test leads (2 pieces 1m each), 2 test terminals, 1 external power supply 230 V 35 mA TU -10 - +35 °C Enclosure material / colour self-extinguishing plastic / black Dimensions L x W x H 180 x 90 x 30 mm Order Data Article-No. 87 00 10 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 197 Monitoring Function tester for MOV and overvoltage protection diodes H45 For testing of the spark-over voltage of lightningand surge voltage arresters. Digital measuring device with large LCD display. Mobile and easyto-handle, usable for the service area. n Digital measuring instrument with large LCD display n 9V battery operation or net work power unit n comprehensive accessories included Technical Data H45 Measured value display LCD, digital, 3,5 stellig in V Measuring range 40 - 1100 V Max. testing voltage 1200 V Test current 800-120 mA Display division 1V Testing period min. 1s bis sich Messwert einstellt Battery 9 V IEC 6F22 / NEMA-1604-A (Alcaline comound battery) External AC/DC adapter 230V AC / 8 -12 VDC / 200mA Typical current consumption in stand-by position 0,2 mA Typical current consumption during measuring activity 20 - 200 mA Typical current consumption display 200 mA Test terminals (4mm banana jack) Operating temperature range n Automatic fixing of indicated value n Scope of delivery includes: 1 carrying case, 1 test leads (2 pieces 1m each), 2 test terminals, 1 external power supply 230V Minuspol: black / Pluspol: red TU -10 - +35 °C Dimensions L x W x H 180 x 90 x 30 mm Enclosure material / colour self-extinguishing plastic / black Order Data Article-No. 198 16 02 00 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Monitoring Portable test equipment for GDT in LSA magazines A46 For the testing of GDT equipped LSA magazines. The test equipment is embedded in a metal case which has additional space for accessories like network adapters and test adapters for different arrester magazines. n PC connection n Individual tester can be stored in a PC or printed via included software n Other test adapters are available on request n Mobile device in aluminium protection case Technical Data A46 Slow ramp (CCITT/VDE) 100 V/s Fast ramp 1000 V/s Measuring range 5-800 V Test current 0,05 mA Auflösung, intern 12 bit = 0,2 V Display resolution 1V Accuracy +/- 1 V +1 % rel. Resolution 0,2 Battery 9 V IEC 22 External AC/DC adapter 8-5 V / 50 mA Typical current consumption in stand-by position 5 mA Typical current consumption during measuring activity 30 mA Max. usable positions 30 pos Order Data Article-No. 87 01 00 Each GDT in the magazine is tested on both polarities, and the static dc sparkover voltage is compared with the tolerance values. The A45 allows for an accurate measuring of the dc sparkover voltage, by detecting the first sparkover with a linear ramp. It is important to measure on both polarities in order to prevent damages to the gas-filled surge arrester. A quality assessment system can be set up with the software PRO-TEST. The A46 can operate entirely remote controlled from a PC via its serial interface. A special optocoupler-based cable is necessary to provide an interference protection for the PC. The whole testing of the magazine takes place automatically, including the comparison of the measured values with the tolerance values and the fault detection. The test of a complete magazine filled with 20 GDTs takes about 13 seconds. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 199 Monitoring Pulse counter Pulse counter For the potential-free measurement of discharge currents of surge protective devices. Easy snapon installation on the earth conductor with the help of an two-piece ring core. n Pulse counting assembly in 1.5 TE DIN railmounted device n including twisted sensor cable (lenght 1 m) n Batteries are included in the delivery scope Technical Data LC 1 Ansprechwelle für Stoßströme (Anstiegszeit ≥ 8µs) > 1 kA Impulsfolge <1s LCD display 0 - 99 Supply Operating temperature range n Push button to adjust the meter reading (e.g. after battery change) 9 V-battery TU -10 - +50 C° Mounting on 35 mm DIN rail Enclosure material / colour Thermoplast, yellow Degree of protection (IEC EN 60529) IP 20 Lenght of connection cable (sensor) max. 1 m Dimension (L x B x H) 63 x 27 x 90 mm Sensor max. conductor cross section 25 mm² Order Data Article-No. 200 87 00 05 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Monitoring Notes Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 201 The strengths of Leutron since 1947 The long experience and, therefore, the lead in research and development makes Leutron one of the leading manufacturers of isolation spark gaps. Intelligently designed components, compact constructions and an ideal choice of rare-gas fillings are only some elements that, in their totality, provide an optimal protection for various applications in the areas of electronics and electrical engineering. Robust and powerful protection against direct lightning strikes – Leutron's isolation spark gaps. Gas-filled isolating spark gaps for more safety: 202 nLow DC and AC voltage protection level n Very high ignition constancy even in demanding environments nMaintenance-free due to automatic signalization in case of an overload nIdeally suited for application in explosion-hazard environments nImproved operator protection due to low sparkover voltage isolating spark gaps filled with rare-gas Secure application even in explosion-hazard environments isolating spark gaps filled with rare-gas Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 203 Isolation spark gap for mounting on DIN rail nHigh discharge capacity up to 100 kA (10/350 µs), class H n Low sparkover voltage Hermetically closed, gas-filled isolation spark gap Fail-safe characteristic: The double fail-save limits the surface temperature in case of a fault Optional remote signalling on request 204 isolating spark gaps filled with rare-gas Isolation spark gaps for areas in danger of explosion: ATEX nHigh discharge capacity up to 100 kA (10/350 µs), class H n Low sparkover voltage Fail-safe characteristic: The double fail-safe limits the surface temperature in case of a fault Hermetically closed, gas-filled isolation spark gap Degree of protection IP 67 (according to IEC EN 60529), suited for outdoor application Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 205 Rare-gas-filled insulation spark gaps Flexible Mounting TSF 100 and 500 Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines.For internal or similar applications. Basic circuit diagram PE 1 n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Free from radioactive substances n High lightning current discharge capacity of 100 kA (10/350 µs) PE 2 Technical Data TSF 100 TSF 500 IEC category/EN type Class H Class H 100 ±20% V= 500 ±15% V= Nominal DC sparkover voltage at 100V/s UagN n High reliability, robust n Stable performance, long service life n Fail-safe characteristic n Test standard EN 50164-3 Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±15% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V 100 kA 100 kA 100 kA 100 kA 100 / 1 A 100 / 1 A 200 / 0,5 A 200 / 0,5 A <70V / <20A V <230V / <100A V Insulation resistance at 10V, 100V > 1 GΩ >1 GΩ Self-capacitance at 1 kHz 6 pF 4 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 Relative humidity 10%...95% rh 10%...95% rh Degree of protection IP 67 IP 67 -40 - +80 °C -40 - +80 °C M8 bolt/nut (NIROSTA stainless steel) M8 bolt/nut (NIROSTA stainless steel) 44 90 69 48 78 01 Lightning impulse current discharge capacity Iimp (10/350 µs) Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause Ipeak In Iwn Nominal alternating discharge current (50 Hz) Spark-gap extinguishing conditions Operating temperature range Terminals Vex TU Order Data Article-No. Accessories Product TSF-H1 Article-No. 44 91 75 For solid fixation of isolation spark gaps TSF100 and TSF500 at the installation. Dimension drawing, see pages 220 to 223 206 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Rare-gas-filled insulation spark gaps Flexible Mounting TSF 50 SWISS Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines. Basic circuit diagram PE 1 n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Fault indication via LED n Test key to check the indicator function n Extremely low sparkover voltage of 50 V AC /100 V DC PE 2 Technical Data n Stable performance, long service life n Fail-safe characteristic n Test standard EN 50164-3 TSF 50 SWISS IEC category/EN type Class 1L Nominal DC sparkover voltage at 100V/s UagN 100 ±20 V= Nominal AC sparkover voltage (50 Hz) Uaw 50 ±20 V Typical impulse sparkover voltage Uas 650 V Max. impulse sparkover voltage Uas 950 V Max. impulse current (10/350µs) Iimp Insulation resistance at 10V, 100V Capacitance at 1 MHz 25 kA > 1 GΩ C 6 pF Relative humidity 10-95% rh Degree of protection (IEC EN 60529) IP 66 Terminals M8 srew terminals Dimensions (Ø × L) 60 x 137 mm Order Data Article-No. 44 91 30 Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 207 Rare-gas-filled insulation spark gaps Flexible Mounting SGO 70 und 350 Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines. Weatherresistant, moulded metal/ceramic isolating spark gap with terminal lugs for M8 screw connection. Waterproof moulded in polyurethan diecast. Basic circuit diagram PE 1 n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Free from radioactive substances n High lightning current discharge capacity of 100 kA (10/350 µs) PE 2 Technical Data SGO 70 SGO 350 IEC category/EN type Class H Class H 100 ±20% V= 500 ±15% V= Nominal DC sparkover voltage at 100V/s UagN Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±15% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V 100 kA 100 kA 100 kA 100 kA 100 / 1 A 100 A Lightning impulse current discharge capacity Iimp (10/350 µs) Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause Ipeak In Iwn Nominal alternating discharge current (50 Hz) Alternating current critical load (50 Hz) Iwgr Insulation resistance at 10V, 100V Spark-gap extinguishing conditions 200 / 0,5s A 200/0,5s A 4.000 / 0,25 A/s 4.000 / 0,25 A/s >1 GΩ >1 GΩ <70V/ <20A V < 230 V Self-capacitance at 1 kHz 9 pF 7 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 Relative humidity 10%...95% rh 10%...95% rh Degree of protection IP 67 IP 67 -40 - +80 °C -40 - +80 °C 47 21 17 47 22 13 Operating temperature range Vex TU n Extremely low sparkover voltage n Highly riliable, robust and waterproof n Fail-safe characteristic n Stable performance, long service life n Test standard EN 50164-3 Order Data Article-No. Dimension drawing, see pages 220 to 223 208 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Rare-gas-filled insulation spark gaps Flexible Mounting TA 100 und 500 C Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines.The product is for outdoor use where a high level of protection against lightning and other climatic influences as well as mechanical stress is needed. PE 1 Basic circuit diagram PE 2 n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Free from radioactive substances n High discharge capacity up to 100 kA n Highly riliable, robust and waterproof Technical Data TA 100 C TA 500 C IEC category/EN type Class H Class H 100 ±20% V= 500 ±15% V= Nominal DC sparkover voltage at 100V/s UagN Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±15% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V 100 kA 100 kA 100 kA 100 kA 100 A 100 A Lightning impulse current discharge capacity Iimp (10/350 µs) Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause Ipeak In Iwn 200 / 0,5 A 200/0,5 A Alternating current critical load (50 Hz) Iwgr 4.000 / 0,25 A/s 4.000 / 0,25 A/s Spark-gap extinguishing conditions Vex <70V / <20A V < 230V/<100A V Insulation resistance at 10V, 100V >1 GΩ >1 GΩ Self-capacitance at 1 kHz 9 pF 7 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 Relative humidity 10%...95% rh 10%...95% rh Degree of protection IP 67 IP 67 -40 - + 80 °C -40 - +80 °C 48 78 14 48 78 27 Nominal alternating discharge current (50 Hz) Operating temperature range TU n Extremely low sparkover voltage n Stable performance, long service life n Fail-safe characteristic n Test standard EN 50164-3 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 209 Rare-gas-filled insulation spark gaps Flexible Mounting SGO 70 and 350 QA Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines.Waterproof isolating spark-gap for underground installation (soil). Moulded in PU diecast, with cables. 1m isol. 1m isol . PE 1 PE 2 Basic circuit diagram n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Free from radioactive substances n High discharge capacity up to 100 kA n Extremely low sparkover voltage Technical Data SGO 70 QA IEC category/EN type Class H Class H 100 ±20% V= 500 ±15% V= Nominal DC sparkover voltage at 100V/s UagN SGO 350 QA Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±15% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V Lightning impulse current discharge capacity I imp (10/350 µs) Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause 100 kA Ipeak In Iwn 100 kA 100 kA 100/1 A 100/1 A 200 / 0,5 A 200 / 0,5s A Alternating current critical load (50 Hz) Iwgr 4.000 / 0,25 A/s 4.000 / 0,25 A/s Spark-gap extinguishing conditions Vex Nominal alternating discharge current (50 Hz) < 70V / <20A V < 230V/< 100A V Insulation resistance at 10V, 100V >1 GΩ >1 GΩ Self-capacitance at 1 kHz 9 pF 7 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 Relative humidity 10%...95% rh 10%...95% rh IP 67 IP 67 -40 - +80 °C -40 - +80 °C 47 21 04 47 21 11 Degree of protection Operating temperature range TU n Highly reliable, stable functioning n Fail-safe characteristic n Including 2m connection cables with 25mm² n SNAM execution n Test standard EN 50164-3 Order Data Article-No. Dimension drawing, see pages 220 to 223 210 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Rare-gas-filled insulation spark gaps ATEX-certificated for explosion hazardous zones TC 100 and 500 A ATEX approved Ex-protection category. Lightningprotective equipotential bonding in hazardous areas, e.g. insulating flanges at gas pipelines, at ca-thodic corrosion protection and protection of pressure transmitters. FS 1 1 M10 Bolzen M10 thread bolt M10 Buchse M10 nut FS 2 2 PE 1 PE 2 n High reliability, robust n Stable performance, long service life n Fail-safe behaviour (twofold) n Patented product n Test standard EN 50164-3 Basic circuit diagram n High-quality industrial ceramics n Rare-gas filled, hermetically sealed n Free from radioactive substances n Extremely low sparkover voltage n High discharge capacity up to 100 kA Technical Data TC 100 A TC 500 A IEC category/EN type Class H Class H 100 ±20% V= 500 ±15% V= Nominal DC sparkover voltage at 100V/s UagN Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±15% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V 100 kA 100 kA 10x 100 kA 100 kA 100/s A 100 A Lightning impulse current discharge capacity Iimp (10/350 µs) Ipeak Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause In Iwn Nominal alternating discharge current (50 Hz) 200/0,5s A 200 / 0,5s A < 70V / < 20A V < 230 V/ 100A V Insulation resistance at 10V, 100V >1 GΩ >1 GΩ Self-capacitance at 1 kHz 20 pF 20 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 Relative humidity 10%...95% rh 10%...95% rh Degree of protection IP 67 IP 67 ATEX protection class Ex II 2G EEx m II T3 ( ZELM 02 ATEX 0095X) EX II 2G EEx m II T3 (ZELM 02 ATEX 0095x) Spark-gap extinguishing conditions Operating temperature range Vex TU -40 - +90 °C - 40 - +90 °C 48 78 30 48 78 50 Order Data Article-No. Accessories Product K1/150 K1/300 IF3 IF1 Article-No. 49 51 06 49 51 08 82 30 16 82 30 11 Connectors are made of hot-dip galvanized steel and have a 20mm drill hole for Installation. Connecting cable set K1 for TC 100A and TC 500A spark gaps Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 211 Rare-gas-filled insulation spark gaps DIN rail mounting TSF for DIN rail mountig Rare-gas-filled spark gap for the lightning protection equipotential bonding, the insulation of electrically separated parts and the bridging of insulating flanges of gas pipelines. Basic circuit diagram PE 1 n AC spark-over voltage : 70 V n DC spark-over voltage : 100 V bzw. 500 V n DC impulse spark-over voltage (1kV/µs): 650 V n Lightning impulse current resistance (10/350µs): 100 kA PE 2 Technical Data TSF 50-Tr TSF 100-Tr TSF 500-Tr IEC category/EN type Class 1L Class H Class H 100 ±20% V= 500 ±20% V= Nominal DC sparkover voltage at 100V/s UagN Nominal AC sparkover voltage (50 Hz) Uaw 70 ±20% V 350 ±20% V Typical impulse sparkover voltage Uas 650 V 950 V Max. impulse sparkover voltage Uas 950 V 1300 V 25 kA 100 kA 100 kA 25 kA 100 kA 100 kA 100 A 100/1 A 200 A / 0,5s A 200/0,5s A Lightning impulse current discharge capacity Iimp (10/350 µs) Nominal impulse discharge current (10 x 8/20) 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause Ipeak In 50 ±15% V Iwn Nominal alternating discharge current (50 Hz) n Mounting on 35 mm DIN rail n Test standard EN 50164-3 n Degree of protection according to IEC EN 60529: IP 20 Alternating current critical load (50 Hz) Iwgr 4.000 A / 0,25s A/s 4000/0,25 A/s Spark-gap extinguishing conditions Vex <70V / < 20A V < 230 V/ < 100 A V Insulation resistance at 10V, 100V >1 GΩ >1 GΩ > 1 GΩ Self-capacitance at 1 kHz 6 pF 6 pF 4 pF Test category/climatic category DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 DIN IEC 60068-1 / 40/90/21 10%...95% rh 10%...95% rh 10%-95% rh -40 - +80 °C -40 - +80 °C -40 - +80 °C 50mm² stranded /35mm² flexible 50mm² stranded /35mm² 50mm² stranded /35mm² flexible flexible 44 90 76 44 90 80 Relative humidity Operating temperature range Max. conductor cross section TU Order Data Article-No. 44 90 85 Dimension drawing, see pages 220 to 223 212 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Rare-gas-filled insulation spark gaps DIN rail mounting TF for mounting rail Protects measuring transformers; lightning and surge voltage protector for 1A respectively 5A cores in current transformers. I 1 / n 1 (x 1 ) Thermoschalter Basic circuit diagram n K1 n Very high impulse and AC current resistivity n No blow-out vents, thus, not requiring any safety clearance to other installations n High insulation resistance Risol: >10 GΩ n Very long service life Pk Technical Data n Lightning impulse current discharge capacity 100 kA (10/350µs) n Rremote signal contact (PK) TF 100Tr/Th-Pk TF 500-Tr TF 500Tr/Th-Pk TF 2000Tr/Th-Pk DC spark-over voltage (Uag) Uag 100 ±20% V= 500 ±20% V= 500 ±20% V= 2000 (-10% / +20%) V= AC spark-over voltage Uaw 70 ±20% V~ 350 ±20% V~ 350 ±20% V~ 1414 (-10% /+-20%) V~ < 3.000 V Impulse sparkover voltage at 1 kV/μs Uas typ. 650 / max. 900 V typ. 1000 / max. 1300 V typ. 1000 / max. 1300 V Impulse sparkover voltage at 1 kV/ns (100 MHz) Uas typ. 1600 / max. 1900 V typ. 2800 / max. 3000 V typ. 2800 / max. 3000 V CapacitanceC ≤ 18 nF ≤ 6 nF ≤ 16 [pF] nF <=16 nF Insulation resistance at 10 V ≥ 1 GΩ ≥ 1 GΩ ≥ 1 GΩ ≥ 1 GΩ 10x 100 kA 10x 100 kA 10x 100 kA 10 x 100 kA 1x 100 kA 1x 100 kA 1x 100 kA 1 x 60 kA 50 As 50 As 50 As 30 As 2500 kJ/Ω 2500 kJ/Ω 2500 kJ/Ω 900 kJ/Ω 20x 60 kA 20x 60 kA 20x 60 kA 20 x 60 kA Lightning impulse current Iimp (10/45 µs) + half-wave 1.6 kA (DIN 48810) (Q) 10 As 10 As 10 As 10 As Lightning impulse current Iimp (10/45µs) + half-wave 1.6 kA (DIN 48810) 100 kJ/Ω 100 kJ/Ω 100 kJ/Ω 100 kJ/Ω 100 A 100 A 100 A 100 A Ris Nominal discharge current (8/20) In Lightning impulse current (10/350 µs) (Iimp) + long-time current 200 A/0.5 s/100 As W/R Lightning impulse current (10/350 µs) (Iimp)+long-time current 200 A/0.5 s/100 As Ipeak Lightning impulse current (10/350 µs) (Iimp)+ long-time current 200 A/0.5 s/100 As Lightning impulse current Iimp (10/45 µs) + half-wave 1.6 kA (DIN 48810) Ipeak 5x Nominal alternating discharge current at 50Hz, 1s, 3min pause Iwn Operating temperature range TU -40 - +75 °C -40 - +75 °C -40 - +75 °C -40 - +75 °C Conductor cross section 25 mm² 25 mm² 25 mm² 25 mm² Max. connection torque for terminals 4,5 Nm 4,5 Nm 4,5 Nm 4,5 Nm 53 43 72 53 43 98 53 43 85 55 04 11 Order Data Article-No. Dimension drawing, see pages 220 to 223 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 213 Smaller, more compact and most efficient Extended metal structures like gas pipelines are endangered by induced AC voltages from high-voltage overhead lines and suchlike. These voltages can cause corrosion and pitting and, therefore, have to be diverted. Leutron's PLPro is the most compact and, at the same time, most robust solution available for such problems. The application of Leutron's worldwide tried and tested technology saves time and money. Protection of outdoor installations: 214 nMonitoring possible by remote measurement of the current flow nLightning current carrying capacity up to lightning protection level LPL 1 nNo interference with detection signals on pipelines nCascadable, i.e., adaptable to the value of the current to divert nReliable diversion of harmful AC voltages in metal structures Protective devices for AC arresting Leutron's protective devices are maintenance-free due to enclosed arresters Protective devices for AC arresting Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 215 AC current diverter for 80 A for the protection of cathodic corrosion protection systems (CCPS) of pipelines nHigh discharge capacity up to 100 kA (10/350 µs), class H n Low sparkover voltage Cascadable to divert higher currents 216 Lightning current up to 100 kA (10/350 µs), suited for lightning protection level LPL 1 Arresters up to 80 A AC No interference with detection signals on pipelines due to a bandpass filter Integrated current transformer to monitor the diverted current continuously Connection terminal up to 150 mm2 Protective devices for AC arresting Reference: V&C Kathodischer Korrosionsschutz Ges.m.b.H., Austria »For a number of years we now use Leutron's PLPro system to divert alternating currents. The systems installed so far operate smoothly, and we never received any complaints from customers. At the insulating flanges of our cathodic corrosion protection systems we very often apply ATEX certified isolation spark gaps TC 100 A. They too work to the satisfaction of our customers. So far no malfunction or break-down occurred.« Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 217 Protective devices for AC arresting AC-current diverter up to AC 80A with lightning protection PLPro With an active cathodic corrosion protection the installation is permanently protected against the electrochemical process of corrosion. For that matter a grid supplied rectifier is inserted between the installation (e.g. a pipeline) and an anode that serves as earth electrode. By connecting two or three PLPro units in parallel the overall current can be elevated up to 80 respectively 120 A. Basic circuit diagram n AC discharge current: 40 or 80 A n Several PLPro devices can be connected in parallel to raise the total discharge current nMaintenance-free, without liquids n No disturbance of search signals Technical Data Rated voltage (P-E) Max. continuous diverting current 50Hz (P-E) Short-time discharge current for 1s/50Hz (P-E) PLPro-40A-iV PLPro-80A-iV Umax 25 V= 25 V= IA 40 A~ 80 A~ Imax 400 A~ 400 A~ Leakage current (P-E) IL ≤ 1 mA ≤ 1 mA Nominal discharge current (8/20 µs) (P-E) In 10x 100 kA 10x 100 kA 100 kA 100 kA -40 - +80 °C -40 - +80 °C Lightning impulse current (10/350) Operating temperature range Iimp TU Terminals (P/E) min. 16 / max. 150 mm² min. 16/max. 150 mm² Current transformer 100:1 A 100:1 A 25 mm² max. 2,5 mm² -20 - +45 °C -20 - +45 °C Mounting type Wall mounting Wall mounting Dimensions L x W x H 400 x 300 x 132 mm 600 x 400 x 132 mm Degree of protection (IEC EN 60529) IP 65 IP 65 55 04 40 55 04 41 Terminals (current transformer i1, i2) Current transformer: operating temperature T n Monitoring of discharge current with integrated current transformer possible n Integrated lightning and surge current protection up to 100 kA (10/350 µs) n Safety switch for discharging the capacitors Order Data Article-No. Dimension drawing, see pages 220 to 223 218 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Standards Test Standards/application standards Test Standards Application standards DIN EN 61643-11 VDE 0675-6-11:2007-08 DIN EN 62305-1 VDE 0185-305-1:2011-10 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and tests (IEC616431:1998 + corrigendum 1998, modified); German version EN 61643-11:2002 + A11:2007 Protection against lightning - Part 1: General principles (IEC 62305-1:2010, modified); German version EN 62305-1:2011 IEC 61643-1:2005-03 Protection against lightning - Part 2: Risk management (IEC 62305-2:2006); German version EN 62305-2:2006 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods DIN EN 61643-21 VDE 0845-3-1:2010-03 Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and test methods (IEC61643-21:2000 + Corrigendum 2001 + A1:2008, modified); German version EN 61643-21:2001 + A1:2009 IEC 61643-21 (2009-04) Ed. 1.1 IEC 61643-21:2000 + A1:2008 DIN EN 62305-2 VDE 0185-305-2: 2006-10 DIN EN 62305-3 VDE 0185-305-3: 2011-10 Protection against lightning - Part 3: Physical damage to structures and life hazard (IEC 62305-3:2010, modified); German version EN 62305-3:2011 DIN EN 62305-4 VDE 0185-305-4:2011-10 Protection against lightning - Part 4: Electrical and electronic systems within structures (IEC 62305-4:2010, modified); German version EN 62305-4:2011 Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods IEC 62305-1 (2010-12) Ed. 2.0 DIN EN 50164-3 VDE 0185-203:2009-09 Protection against lightning - Part 2: Risk management Lightning Protection Components (LPC) - Part 3: Requirements for isolating spark gaps; German version EN 50164-3:2006 + A1:2009 DIN EN 60715:2001-09 Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installations (IEC 60715:1981 + A1:1995); German version EN 60715:2001 Protection against lightning - Part 1: General principles IEC 62305-2 (2010-12) Ed. 2.0 IEC 62305-3 (2010-12) Ed. 2.0 Protection against lightning - Part 3: Physical damage to structures and life hazard IEC 62305-4 (2010-12) Ed. 2.0 Protection against lightning - Part 4: Electrical and electronic systems within structures DIN EN 60529 VDE 0470-1:2000-09 Degrees of protection provided by enclosures (IP code) (IEC 60529:1989 + A1:1999); German version EN 60529:1991 + A1:2000 IEC 60529 (2001-02) Ed. 2.1 Degrees of protection provided by enclosures (IP Code) Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 219 dimension drawing 220 CT Product line EnerPro 230 SDU MP RK Product line CPS+ Product line PP PV 800 and PP PV 1000 DataPro (DP) Product line EnerPro D 230 SM CT PV Product line DataPro RJ45-CAT6-48V-Tr EnerPro D 230 KM Busbar KA DataPro RJ45 f/f NM 22V/5kA MP Product line DataPro-1xRJ45PoE-Alu Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de dimension drawing DataPro 8xRJ45-6V-WG TelPro LSA – SSCT magazines DataPro 10LSA (10 SSCT) DataPro 1x8 to 3x8RJ45-19“ TelPro LSA – SSCT magazines SSCT disconnection module LSA 2/10-TR DataPro 4x8 to 6x8RJ45-19“ TelPro LSA – SSCT magazines SSCT connection module LSA 2/10-AN DataPro ISDN-aP LSA – SSCT Connector fine and coarse protection SSCT ground module LSA 2/10-ER38-rot DataPro-TAE/NFN-aP LSA – SSCT Connector coarse protection LSA – SSCT frame Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 221 dimension drawing 222 SSCT ground bar DataPro BNC 50 Ohm DataPro Koax 7/16 SSCT magazine cover AntPro 5,8GHz SMA AntPro Lambda 7/16 0.42GHz SSCT backmount frame AntPro Koax-GSM-N/230 (f/f) DataPro Koax 7/16 (f/f) DataPro-SAT and DataPro-Radio/TV AntPro Lambda/4 N 0.51GHz AntPro Lambda/4 7/16 TRI DataPro Koax-8V-BNC AntPro Lambda/4 N 0.51GHz (f/f) AntPro Lambda/4 7/16 TRI (f/f) Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de dimension drawing EnerProFilter 230-Tr, EMC Filter TSF 50 SWISS EPF, EMC Filter (single-phase) SGO 70 and 350 EPF, EMC Filter (three-phase) up to 35 A TA 100C and 500C EPF, EMC Filter (three-phase) from 63 A SGO 70QA and 350QA TSF 100 and 500 TC 100A and 500A PLPro 40A-IV Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 223 Technical terms A Active Parts Active parts are conductors and conductive parts of equipment that are alive under normal operational conditions. Aging Aging is the alteration of the original conductivity. It is caused by disturbance pulses, normal operation or unfavourable environmental conditions. Approach (today: Separation Distance) An approach is a too narrow distance between the lightning protection installation and conductive installations or electrical installations with a risk of a flashover or breakdown at lightning strikes. Arc Voltages Ubo The arc voltage is the instantaneous value of the voltage over a discharge path during an arc discharge process. Arresters Equipment that in general consists of voltage-controlled resistors and/or spark gaps. Both items can be used separately or connected in series or in parallel. Arresters protect other electrical equipment or installations against unacceptable high surge voltages. Asymmetrical Interference “Asymmetrical” means that the interference source or drain is related to the ground. It exists a capacitive or galvanic connection to the protective conductor. Asymmetrical Voltage, Common-Mode Voltage Average voltage between every conductor and a specified reference point, usually reference earth or ground. B C 224 D Direct or Close-up Strikes Direct and close-up strikes cause surge voltages with an energy content that contains a considerable part of the total energy of a lightning discharge. Disconnection Device If an arrester fails to operate, the disconnection device separates it from the power grid to avoid a fire hazard and to report the defective arrester. Note: It is not the task of the disconnection device to ensure the protective measure „Protection at indirect contact“. Disturbance Voltage, symmetrical The symmetrical disturbance voltage is a disturbance voltage between two wires of a conductor (e.g. at a double-circuit line) or between the terminals of an electrical installation for such a line. E Earth Earth signifies the ground or the soil. Earthing (noun) Earthing refers to the total of all means and measures for earthing. Earthing (verb) To earth means to connect a conductive part, e.g. the lightning protection installation, via an earth-termination system to the earth. Earthing Conductor The earthing conductor connects the installation which has to be earthed with the earthing electrode, as far as the earthing conductor runs above soil or insulated in the soil. Burst A burst consists of repeatedly occurring pulses within a certain time period. Earthing Electrode An earthing electrode is a conductor buried into the ground with an electrically conductive connection to the earth. Parts of connectors that run to the earthing electrode which are lying non-insulated in the ground are part of the earthing electrode as well. Combined Arrester The combined arrester is a surge-voltage protection device consisting of lightning current arrester and surge arrester. Electromagnetic Compatibility (EMC) The electromagnetic compatibility of a device or a system is its capability of a satisfactory operation in its electromagnetic environment, without causing unacceptable electromagnetic disturbances to other installations in this environment. Combined Impulse A combined impulse is generated by a combination wave generator which generates a no-load impulse voltage (1.2/50), respectively, a short-circuit impulse current (8/20). The voltage, the amplitude of the current and the waveforms are determined by the generator and the impedance of the SPD. The ratio of the peak values of the no-load voltage and the short-circuit current is 2 Ω. This value is called the fictitious impedance Zf. The short-circuit current is referred to as Ics. Uoc is the no-load voltage of the generator. Electromagnetic Interference The electromagnetic interference refers to a quality loss in operational behaviour, a malfunction or the breakdown of an electrical or electronically device caused by an electromagnetic disturbance. Critical Discharge Current iSG The critical discharge current is a current pulse of the waveform 8/20 μs which just about triggers the disconnection device and which does not yet lead to a mechanical damage of the arrester. Endurance Test In an endurance test the surge arrester has to undergo load tests, that simulate loads frequently occurring in practice. Electrostatic Discharge (e.s.d.) An electrostatic discharge is the transfer of electric charges between objects with different electrostatic potentials, which takes place at approximation or contact. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Technical terms Equipotential Bonding (Potential Equalization) Potential equalization means to remove potential differences (at the operation of consumer‘s electrical installations), e.g. between the protective conductor of the electrical power installation and the pipes for the water, gas and heating supply, as well as between the individual pipes. The equipotential bonding at lightning effects requires measures beyond the specifications of VDE 0190. Therefore, the lightning protection installation is connected to other conductive installations via conductors or isolation spark gaps and, if necessary, to active parts of electrical installations via surge protection devices. These measures are called “lightning protection potential equalization”. Impulse Sparkover Voltage of a Surge Protection Device Highest voltage value between the electrodes of the spark gap of a surge protection device, just before the sparkover occurs. Impulse Voltage (1.2/50) This impulse voltage has a front time (between 10 % and 90 % of its peak value) of 1,2 μs and a time to half-value of 50 μs (at Uoc = 6 kV). Equipotential Bonding Bar This bar connects protective conductors, potential equalization conductors and, where applicable, functional earthing conductors with the earthing conductor and the earth electrodes. F G I Follow-on Current If The follow-on current flows through the SPD after the diverting process. It is supplied from the grid and differs fundamentally from the continuous operating current. Foundation Earthing Electrode The foundation earthing electrode is a conductor that is embedded into the concrete foundation of a construction. Gas-filled Surge Arrester (GDT) A gas-filled surge arrester is a discharge path filled with another gas than air, normally rare gas. Ground Resistance The ground resistance is the resistance between the earthing system and the reference earth. The amount of the ground resistance depends on the interaction of the individual earthing electrodes. Impulse Current (8/20) This impulse current has a front time of 8 μs and a time to half-value of 20 μs. Impulse Withstand Voltage Ust The impulse withstand voltage is the peak value of the highest pulse voltage of a predefined waveform and polarity, which does not result in a breakdown under predefined test conditions. The impulse withstand voltage is equal to or higher as the rated impulse withstand voltage. Insertion Loss The insertion loss of an SPD is, at a given frequency, the ratio of the voltages at a supply network point immediately downstream to the SPD before and after the insertion of this SPD. The value is given in decibel. Insulation Resistance Riso The insulation resistance is the resistance of the surge arrester in the non-conductive state. Interference Suppression Interference suppression comprises all measures to abate or avoid electromagnetic interferences. Isolation Spark Gap The isolation spark gap is a spark gap to isolate conductive parts of an installation. When the spark gap is triggered by a lightning strike, the parts are temporarily conducted (lightning-protection equipotential bonding). L Lightning Current Arrester The lightning current arrester is a surge-voltage protection device which is capable of carrying direct lightning currents. Impulse Discharge Current Discharge current that flows through the arrester after it is triggered. It is given as a peak value. The nominal impulse discharge current is the peak value of an impulse current of the pulse form 8/20 μs. Lightning Impulse Current Discharge (Lightning Impulse Current) The 10/350 μs lightning impulse current has a front time of 10 μs and a time to half-value of 350 μs. Lightning Impulse Current Iimp The lightning impulse current Iimp is defined by its peak value Imax, its charge Q and the specific energy W/R with a 10/350 μs waveform. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 225 Technical terms Potential Equalization Conductor The potential equalization conductor is a conductive link to achieve potential equalization. Lightning Protection Installation The lightning protection installation is the sum of all equipment for the external and internal lightning protection of the installation to be protected. Potential Equalization Installation The potential equalization installation is the total of all interconnected potential equalization conductors, including all other conductive parts which work in the same way, e.g. housings or other conductive installations. The potential equalization installation can either be the earth-termination system or part of it. Lightning Surge Voltage The lightning surge voltage is a surge voltage caused by a lightning discharge. Longitudinal Voltage Drop The longitudinal voltage drop is a means (instead of the insertion loss) to evaluate overvoltage arresters for d.c. voltages or low operating frequencies up to a maximum of 400 Hz. The longitudinal voltage drop is measured along the current path or paths at nominal current and, where applicable, operating frequency. M Main Supply Short-Circuit Current IK The main supply short-circuit current is the short-circuit current which results from the impedance of the test network and the connecting cables at the installation point of the test object. Measured Limiting Voltage Maximum voltage that is measured at the terminals of an SPD while pulses with a preset form and amplitude are applied. N Power-Frequency Withstand Voltage The power-frequency withstand voltage is the r.m.s. value of the highest sinusoidal voltage at system frequency, which does not result in a breakdown under predefined test conditions. Protection Level Up The protection level is a parameter which characterizes the performance of an SPD to limit the voltage between its terminals. The protection level is chosen from a list of standard values and has to exceed the highest value of the measured limiting voltages. Protection Path The parts of an SPD can be connected as “conductor against conductor” or “neutral conductor against earth”, or a combination of these possibilities. These methods of connection are called protection paths. Pulse A pulse is a rapid, temporary change of a physical parameter followed by a fast change back to the original value. R Nominal Alternating Discharge Current Iwn The nominal alternating discharge current is the alternating current with frequencies between 15 and 62 Hz (primarily 50 Hz), which the test object is dimensioned for in a specific test procedure. Rate of Rise The rate of rise is the average change rate of a parameter between two certain values, e.g. between 10 % and 90 % of the peak value. Nominal Impulse Discharge Current In The nominal impulse discharge current is the peak value of a current with the waveform 8/20 that flows through a surge protection device. It is used to classify the test for class II surge protection devices. Rated Voltage of an Arrester Uc Maximum acceptable root-mean-square value of the power-frequency a.c. voltage that can be permanently applied to the terminals of the arrester. Nominal Load Current IL The nominal load current is the maximum continuous, alternating or direct current which can flow from the output of an SPD to the connected load. Nominal Voltage UN The nominal voltage, as a rounded voltage value, specified by the manufacturer of an electrical apparatus to identify it and to specify the voltage range for which it is designed. O Overvoltage Category The overvoltage category is the classification of a piece of electrical equipment to the expected overvoltages. 226 P The test is carried out according to the test procedure of the operation duty test. It is used to classify the test for class I surge protection devices. Reference Earth Reference earth is the reference ground (especially the earth’s surface) that is so far apart from the earthing electrodes that, if a current is diverted into the ground, no relevant voltage differences occur between the points of this area. Remote Signalling Contact Remote signalling contacts belong to a circuit which is separated from the main circuit of the SPD. The disconnection device of the SPD and/or an operation indication are part of the same circuit. Remote Strikes Remote strikes cause surges with a considerable smaller energy content compared to close-up strikes. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Technical terms Residual Current Protective Device (RCD) Residual current protective devices disconnect the circuit if the residual current against earth exceeds a certain value. Transverse Voltage The transverse voltage is the interference voltage which occurs between two conductors of the same circuit. Residual Voltage Ures The residual voltage is the peak value of the voltage that appears between the terminals of an SPD during the flow of a discharge current or immediately after it. Triggering Current of the Disconnection Device The triggering current of the disconnection device is the root-meansquare value of the current through the arrester, which causes the disconnection device to operate within 30 seconds. Short-circuit Withstand Capability The short-circuit withstand capability is the highest unaffected shortcircuit current the surge protection device can withstand. Triggering Triggering is referred to, if either the peak value of the ohmic component of the current through the arrester reaches 5 mA or a voltage drop caused by the rise of the peak value of the current through the arrester exceeds 5 mA. S Sparkover Voltage The sparkover voltage is the highest instantaneous value of the voltage at the terminals of an arrester, just before it is triggered. Specialist in Lightning Protection A specialist in lightning protection has a professional training, knowledge and expertise as well as knowledge of the corresponding regulations that allow him to assess the work assigned to him as well as to identify possible dangers. (To judge the professional training, one can also consider several years of working in the corresponding field.) Status Display The status display indicates the state of operation of an SPD. Surge Voltage A surge voltage is a voltage that puts people and/or technical equipment like conductors and devices at risk. It can permanently (overvoltage) or temporarily (surge voltage) occur between conductor and earth in error-free installations (in disconnected conductors as well). Surge-voltage Protection Device (SPD A surge-voltage protection device limits transient surges and diverts impulse currents. It includes at least one non-linear component. T Temperature Range The temperature range describes the lowest and highest temperatures that are allowed at or inside the housing. For devices without self-heating this range refers to the ambient temperature. For devices with self-heating it indicates the maximum operating temperature range. TOV Characteristics The TOV characteristics describe the behaviour of an SPD to which a temporary overvoltage (TOV) is applied for a certain period of time. Transient A transient is a non-periodic and very short positive or negative change of voltage or current between two steady states. transient A transient behaviour describes the behaviour of a phenomenon or value which changes between two consecutive steady states in a very short time in comparison to the considered timescale. V W Varistors A varistor is a bipolar non-linear resistor with symmetrical voltagecurrent characteristics. Its resistance decreases with increasing voltage. Withstand Voltage The withstand voltage is the maximum voltage that can be applied to a current-limiting component of an SPD without affecting it. This voltage can be equal to the highest continuous operating voltage Uc of the SPD or higher, depending on the components inside the SPD. Abbreviations CCP Cathodic Corrosion Protection CCPS Cathodic Corrosion Protection System EBS Equipotential Bonding Strip ESD Electrostatic Discharge FM Remote Signalling Contact (Changeover Contact) FS Fail-safe GDT Gas-Filled Surge Arrester LEMP Lightning Electromagnetic Impulse LPL Lightning Protection Level LPMS LEMP Protection Measures System LPS Lightning Protection System LPZ Lightning Protection Zone MBC Miniature Circuit Breaker MOV Metalloxyd Varistor Potential-free Contact (Break Contact) PK RCD Residual Current Device SEMP Switching Electromagnetic Pulse SPD Surge Protective Device SSCT Solderless and Screwless Connection Technology SVE Surge Voltage Protection Equipment SVP Surge Voltage Protector Technical Connection Requirements for Electrical Power TAB Installations Temporary Overvoltage TOV VDEW Vereinigung deutscher Elektrizitätswerke e.V. (German Association for the Power Supply Industry) VdS Verband der Sachversicherer (Property Insurer Association) Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 227 Product Register Numeric Item no. Product name Item no. Product name Page Item no. Product name Page 140 25 30 85 EPF 230V/35A-S 177 04 00 01 AntPro Koax-GSM-N/230 162 24 00 42 DP 1LSA-15-PTC 04 00 04 AntPro Koax-GSM-N-230(f/f) 162 24 00 43 DP 1LSA-24-PTC 140 25 31 00 EPF 230/400V/35A-W 179 04 00 20 AntPro Lambda/4 N 0.51GHz 163 24 00 44 DP 1LSA-48-PTC 141 25 31 30 EPF 230/400V/63A-E 180 04 00 21 AntPro Lambda/4 N 0.51GHz (f/f) 164 24 00 45 DP 1LSA-60-PTC 141 25 31 40 EPF 230/400V/100A-E 180 04 00 22 AntPro Lambda/4 N 0.8GHz 163 24 00 46 DP 1LSA-110-PTC 141 25 31 60 EPF 230/400V/200A-E 180 04 00 23 AntPro Lambda/4 N 2.0GHz 163 24 00 47 DP 1LSA-180FS 142 26 12 12 DP 2x1-12V/12V-0,3Ω -Tr 187 04 00 24 AntPro Lambda/4 N 2.0GHz (f/f) 164 24 00 48 DP 1LSA-T110FS-PTC 143 26 24 24 DP 2x1-24V/24V-0,3Ω -Tr 187 04 00 30 AntPro Lambda/4 7/16 TRI 167 24 00 49 DP 1LSA-TK180FS 144 26 30 30 DP 2x1-30V/30V-0,3Ω-Tr 187 04 00 31 AntPro Lambda/4 7/16 TRI (f/f) 168 24 00 61 DP 1LSA-C48FS-PTC 146 26 36 36 DP 2x1-36V/36V-0,3Ω -Tr 187 04 04 25 AntPro Lambda 7/16 0.42GHz 169 24 00 62 DP 1LSA-C60FS-PTC 146 27 00 00 DP 2x1-RLC-Tr 189 04 58 00 AntPro 5,8GHz-SMA 161 24 00 63 DP 1LSA-C5FS-PTC 145 27 03 03 IsoProData 150V/150V-Tr 182 04 58 02 AntPro 5,8GHz-R-SMA 161 24 00 64 DP 1LSA-C12FS-PTC 145 27 04 04 DP2x1-150V/150V-Tr 184 10 10 00 DP Koax 7/16 165 24 00 65 DP 1LSA-C15FS-PTC 145 27 06 06 DP2x1-6V/6V-Tr 183 10 10 01 DP Koax 7/16 (f/f) 166 24 00 66 DP 1LSA-C24FS-PTC 145 27 12 12 DP2x1-12V/12V-Tr 183 16 02 00 H45 198 24 01 00 LSA 2/10-AN 149 27 15 15 DP2x1-15V/15V-Tr 183 16 05 20 DP FME-AD 170 24 01 02 LSA 2/10-TR 150 27 24 24 DP2x1-24V/24V-Tr 183 151 27 30 02 IsoProData-Tr 103 17 00 10 KA1/2 67 24 01 04 LSA 2/10-ER38-rot 17 00 20 KA1/4 67 24 01 06 TelPro LSA 2/10-2E 8x6 135 27 30 30 DP2x1-30V/30V-Tr 184 17 00 30 KA1/6 67 24 01 08 LSA 2/10 KSR 152 27 36 36 DP2x1-36V/36V-Tr 184 17 00 40 KA1/8 67 24 01 09 LSA 2/10 AD 152 27 48 48 DP2x1-48V/48V-Tr 184 17 01 10 DAK 2x 16 60 24 01 10 LSA 2/10-MW10-25/22 152 27 60 60 DP2x1-60V/60V-Tr 184 19 40 13 DP 1x8RJ45-19“ 128 24 01 12 LSA-Anlegewerkzeug 152 27 80 80 DP2x1-80V/80V-Tr 184 19 40 23 DP 2x8RJ45-19“ 128 24 01 13 TelPro LSA-2EH230-10kA 135 28 04 04 DP3x1-150V/150V-Tr 186 19 40 33 DP 3x8RJ45-19“ 128 24 01 14 TelPro LSA-2EH230F-10kA 135 28 12 12 DP3x1-12V/12V-Tr 185 19 40 43 DP 4x8RJ45-19‘‘ 129 24 01 15 TelPro LSA-2EL230-20kA 135 28 15 15 DP3x1-15V/15V-Tr 185 19 40 50 DP 8xRJ45-6V-WG 127 24 01 16 TelPro LSA-2EH350-10kA 135 28 24 24 DP3x1-24V/24V-Tr 185 19 40 53 DP 5x8RJ45-19“ 129 24 01 17 TelPro LSA-2EH90-10kA 135 28 30 30 DP3x1-30V/30V-Tr 185 19 40 63 DP 6x8RJ45-19“ 129 24 01 18 TelPro LSA 2/10-3E 8x13 136 28 36 36 DP3x1-36V/36V-Tr 186 21 00 20 DataPro-SAT 158 24 01 19 TelPro LSA 2/10-3EH230E-10kA 136 28 48 48 DP3x1-48V/48V-Tr 186 21 00 30 DataPro-Radio/TV 158 24 01 23 TelPro LSA-3EH230F1E-10kA 136 28 60 60 DP3x1-60/60V-Tr 186 24 00 02 EnerPro 230 SDU 57 24 01 24 TelPro LSA-3EL230E-20kA 136 28 70 50 DP 2x1-RLC/50V-Tr 188 24 01 25 TelPro LSA-3EL230F1E-20kA 136 32 50 00 CPS+ 230 53 32 50 01 CPS+ 230Tel/Net 53 24 00 04 DataPro-TAE/NFN-aP 228 Page 131 24 00 05 DP RJ45-CAT6-48V-Tr 124 24 01 26 TelPro LSA-3EH90E-10kA 136 24 00 11 DP RJ45 f/f 125 24 01 27 TelPro LSA-3EH90F1E-10kA 136 32 50 02 CPS+ 230SAT 53 24 00 13 DataPro ISDN-aP 130 24 01 28 TelPro LSA 2/10-2E 8x20 137 32 50 03 CPS+ 230TV 53 24 00 17 DP2-2MB-Tr 190 24 01 29 TelPro LSA 2EY230-20kA 137 35 10 30 UAS 230-Tr 66 24 00 21 DP 1xRJ45-PoE-Alu 126 24 01 31 TelPro LSA-2EY90-20kA 137 36 05 22 NM 220V/5kA 56 24 00 25 DP 10LSA-12V 147 24 01 32 TelPro LSA-2EY350-20kA 137 36 20 30 EP D 230 SM 54 24 00 26 DP 10LSA-PTC-12V 148 24 01 33 LSA 2/10-ES 152 36 20 35 EP D 230 KM 55 24 00 27 DP 10LSA-24V 147 24 01 36 LSA 2/10 KS-120 152 37 44 00 PP PV 800 60 24 00 28 DP 10LSA-PTC-24V 148 24 01 37 LSA DIN ADAPT 152 37 44 01 PP PV 800/FM 60 24 00 31 DP 1LSA-5 138 24 01 40 DP 10LSA-110 147 37 44 02 PP PV 1000 61 24 00 32 DP 1LSA-12 138 24 01 42 DP 10LSA-PTC 110 148 37 44 03 PP PV 1000/FM 61 24 00 33 DP 1LSA-15 138 25 30 16 EPF 230V/16A-Tr 176 44 90 69 TSF 100 206 24 00 34 DP 1LSA-24 138 25 30 17 EPF 230V/25A-Tr 176 44 90 76 TSF 50-Tr 212 24 00 36 DP 1LSA-30 139 25 30 20 EPF 230V/16A-S 177 44 90 80 TSF 100-Tr 212 24 00 37 DP 1LSA-48 139 25 30 22 EPF 60V/16A-S 177 44 90 85 TSF 500-Tr 212 24 00 38 DP 1LSA-60 139 25 30 25 EPF 230V/16A-W 178 44 91 30 TSF 50 SWISS 207 24 00 39 DP 1LSA-110 139 25 30 45 EPF 230/400V/16A-W 179 44 91 75 TSF-H1 206 24 00 40 DP 1LSA-5-PTC 140 25 30 53 EPF 48V/25A-S 177 47 21 04 SGO 70 QA 210 24 00 41 DP 1LSA-12-PTC 140 25 30 80 EPF 230/400V/25A-W 179 47 21 11 SGO 350 QA 210 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Product Register Numeric Item no. Product name Page Item no. Product name Page 47 21 17 SGO 70 208 96 00 52 CT-T2/1+0-275 39 96 01 51 CT-T2/1+0-350-VA-FM Item no. Product name Page 47 47 22 13 SGO 350 208 96 00 53 CT-T2/1+0-275-FM 39 96 01 52 CT-T2/4+0-350-VA 42 48 78 01 TSF 500 206 96 00 54 CT-T2/4+0-275 28 96 01 53 CT-T2/4+0-350-VA-FM 42 48 78 14 TA 100 C 209 96 00 55 CT-T2/4+0-275-FM 28 96 01 83 CT-T2-150-M 39 48 78 27 TA 500 C 209 96 00 56 CT-T2/3+1-350 31 96 01 84 CT-T2-275-M 33 48 78 30 TC 100 A 211 96 00 57 CT-T2/3+1-350-FM 31 96 01 85 CT-T2-350-M 31 48 78 50 TC 500 A 211 96 00 58 CT-T2/3+0-350 33 96 01 86 CT-T3/Y1-24 50 49 51 06 K1/150 211 96 00 59 CT-T2/3+0-350-FM 33 96 01 87 CT-T3/Y1-24-FM 50 49 51 08 K1/300 211 96 00 62 CT-T2/2+0-350 35 96 01 90 CT-T3/Y1-48 50 53 43 72 TF 100Tr/Th-Pk 213 96 00 63 CT-T2/2+0-350-FM 35 96 01 91 CT-T3/Y1-48-FM 50 53 43 85 TF 500Tr/Th-Pk 213 96 00 64 CT-T2/1+1-350 37 96 01 94 CT-T3/Y1-60 51 53 43 98 TF 500-Tr 213 96 00 65 CT-T2/1+1-350-FM 37 96 01 95 CT-T3/Y1-60-FM 51 54 43 30 DP Koax BNC 50Ohm 160 96 00 66 CT-T2/1+0-350 39 96 01 96 CT-T2-275-VA-M 42 54 43 40 DataPro Koax-8V-BNC-75 Ohm 159 96 00 67 CT-T2/1+0-350-FM 39 96 01 97 CT-T2-350-VA-M 42 54 43 46 DataPro Koax-8V-BNC 159 96 00 68 CT-T2/4+0-350 29 96 01 98 CT-T3/Y1-120 51 55 04 11 TF 2000Tr/Th-Pk 213 96 00 69 CT-T2/4+0-350-FM 29 96 02 02 CT-T3/Y1-230 51 55 04 40 PLPro-40A-iV 218 96 00 70 CT-T2/3+1-440 31 96 01 99 CT-T3/Y1-120-FM 51 55 04 41 PLPro-80A-iV 218 96 00 71 CT-T2/3+1-440-FM 31 96 02 03 CT-T3/Y1-230-FM 51 82 30 11 IF1 211 96 00 72 CT-T2/3+0-440 33 96 02 04 CT-T3/Y3-230 52 82 30 16 IF3 211 96 00 73 CT-T2/3+0-440-FM 33 96 02 05 CT-T3/Y3-230-FM 52 87 00 05 LC 1 200 96 00 76 CT-T2/2+0-440 35 96 02 07 CT-T1/3+1-350-FM 12 87 00 10 H35 197 96 00 77 CT-T2/2+0-440-FM 35 96 02 09 CT-T1/3+0-350-FM 13 87 01 00 A46 199 96 00 78 CT-T2/1+1-440 37 96 02 13 CT-T1/2+0-350-FM 14 87 01 50 H65 196 96 00 79 CT-T2/1+1-440-FM 37 96 02 15 CT-T1/1+1-350-FM 15 96 00 01 CT-T1+2/3+1-350-FM 20 96 00 80 CT-T2/1+0-440 39 96 02 17 CT-T1/1+0-350-FM 16 96 00 03 CT-T1+2/3+0-350-FM 21 96 00 81 CT-T2/1+0-440-FM 39 96 02 20 CT PV-T2/2-0/600 62 96 00 07 CT-T1+2/2+0-350-FM 22 96 00 82 CT-T2/4+0-440 29 96 02 21 CT PV-T2/2-0/600-FM 62 96 00 09 CT-T1+2/1+1-350-FM 23 96 00 83 CT-T2/4+0-440-FM 29 96 02 22 CT PV-T2/2-0/1000 62 96 00 11 CT-T1+2/1+0-350-FM 24 96 00 94 CT-T2/1+0-600 39 96 02 23 CT PV-T2/2-0/1000-FM 62 96 00 24 CT-T2/1+0-75 38 96 00 95 CT-T2/1+0-600-FM 39 96 02 24 CT PV-T2/2+1/600 63 96 00 25 CT-T2/1+0-75-FM 38 96 01 26 CT-T2/3+1-275-VA 43 96 02 25 CT PV-T2/2+1/600-FM 63 96 00 28 CT-T2/3+1-150 30 96 01 27 CT-T2/3+1-275-VA-FM 43 96 02 26 CT PV-T2/2+1/1000 63 63 96 00 29 CT-T2/3+1-150-FM 30 96 01 28 CT-T2/3+0-275-VA 44 96 02 27 CT PV-T2/2+1/1000-FM 96 00 30 CT-T2/3+0-150 32 96 01 29 CT-T2/3+0-275-VA-FM 44 96 02 28 CT PV-T2/2+GDT/600 64 96 00 31 CT-T2/3+0-150-FM 32 96 01 32 CT-T2/2+0-275-VA 45 96 02 29 CT PV-T2/2+GDT/600-FM 64 96 00 34 CT-T2/2+0-150 34 96 01 33 CT-T2/2+0-275-VA-FM 45 96 02 33 CT-T1/0+1-FS-FM 17 96 00 35 CT-T2/2+0-150-FM 34 96 01 34 CT-T2/1+1-275-VA 46 96 02 34 CT-T2/0+1-FS 40 96 00 36 CT-T2/1+1-150 36 96 01 35 CT-T2/1+1-275-VA-FM 46 96 02 35 CT-T2/0+1-FS-FM 40 96 00 37 CT-T2/1+1-150-FM 36 96 01 36 CT-T2/1+0-275-VA 47 96 02 36 CT-T1+2-350-M 20 96 00 38 CT-T2/1+0-150 38 96 01 37 CT-T2/1+0-275-VA-FM 47 96 02 37 CT-T1-350-M 12 96 00 39 CT-T2/1+0-150-FM 38 96 01 38 CT-T2/4+0-275-VA 42 96 02 38 CT-T1-NPE-M 12 96 00 40 CT-T2/4+0-150 28 96 01 39 CT-T2/4+0-275-VA-FM 42 96 02 39 CT-T2-NPE-M 31 96 00 41 CT-T2/4+0-150-FM 28 96 01 40 CT-T2/3+1-350-VA 43 96 02 40 CT-T3/Y1-24-M 51 96 00 42 CT-T2/3+1-275 30 96 01 41 CT-T2/3+1-350-VA-FM 43 96 02 44 CT-T3/Y1-230-M 51 96 00 43 CT-T2/3+1-275-FM 30 96 01 42 CT-T2/3+0-350-VA 44 96 02 45 CT-T3/Y3-230-M 52 96 00 44 CT-T2/3+0-275 32 96 01 43 CT-T2/3+0-350-VA-FM 44 96 02 46 CT PV-T2-600-M 62 96 00 45 CT-T2/3+0-275-FM 32 96 01 46 CT-T2/2+0-350-VA 45 96 02 47 CT PV-T2-1000-M 62 96 00 48 CT-T2/2+0-275 34 96 01 47 CT-T2/2+0-350-VA-FM 45 96 02 48 CT PV-T2-GDT-M 64 96 00 49 CT-T2/2+0-275-FM 34 96 01 48 CT-T2/1+1-350-VA 46 96 00 50 CT-T2/1+1-275 36 96 01 49 CT-T2/1+1-350-VA-FM 46 96 00 51 CT-T2/1+1-275-FM 36 96 01 50 CT-T2/1+0-350-VA 47 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 229 Product Register Numeric Item no. Product name Item no. Product name Page 96 03 00 CT PV-T2/2+GDT/1000 64 97 10 04 MP RK GDT+5V-Ad-Ad 96 03 01 CT PV-T2/2+GDT/1000-FM 64 97 10 05 MP RK GDT+12V-Ad-Ad 106 97 00 00 MP Base 2x2-R 85 97 10 06 MP RK GDT+24V-Ad-Ad 106 97 00 01 MP Base 2x2-R GDT 85 97 10 07 MP RK GDT+36V-Ad-Ad 106 97 00 03 MP Base 2x2 80 97 10 08 MP RK GDT+48V-Ad-Ad 107 97 00 04 MP Base 2x2 GDT 80 97 10 09 MP RK GDT+60V-Ad-Ad 107 97 00 07 MP 2x2 GDT ST 80 97 10 10 MP RK GDT+180V-Ad-Ad 107 97 00 10 MP 1x2 GDT ST 81 97 10 11 MP RK GDT+5V-Ad-Pg 108 97 00 11 MP 2x2 GDT+5V-Ad-Ad ST 84 97 10 12 MP RK GDT+12V-Ad-Pg 108 97 00 12 MP 2x2 GDT+12V-Ad-Ad ST 84 97 10 13 MP RK GDT+24V-Ad-Pg 108 97 00 13 MP 2x2 GDT+24V-Ad-Ad ST 84 97 10 14 MP RK GDT+36V-Ad-Pg 108 97 00 14 MP 2x2 GDT+36V-Ad-Ad ST 84 97 10 15 MP RK GDT+48V-Ad-Pg 109 97 00 15 MP 2x2 GDT+48V-Ad-Ad ST 85 97 10 16 MP RK GDT+60V-Ad-Pg 109 97 00 16 MP 2x2 GDT+60V-Ad-Ad ST 85 97 10 17 MP RK GDT+180V-Ad-Pg 109 97 00 17 MP 2x2 GDT+180V-Ad-Ad ST 85 97 10 18 MP RK GDT+5V-Ad-Ad-Pg 110 97 00 18 MP 1x2 GDT+5V-Ad-Ad ST 86 97 10 19 MP RK GDT+12V-Ad-Ad-Pg 110 97 00 19 MP 1x2 GDT+12V-Ad-Ad ST 86 97 10 20 MP RK GDT+12V-Ad-Ad-Pg 110 97 00 20 MP 1x2 GDT+24V-Ad-Ad ST 86 97 10 21 MP RK GDT+36V-Ad-Ad-Pg 110 97 00 21 MP 1x2 GDT+36V-Ad-Ad ST 86 97 10 22 MP RK GDT+48V-Ad-Ad-Pg 111 97 00 22 MP 1x2 GDT+48V-Ad-Ad ST 87 97 10 23 MP RK GDT+60V-Ad-Ad-Pg 111 97 00 23 MP 1x2 GDT+60V-Ad-Ad ST 87 97 10 24 MP RK GDT+180V-Ad-Ad-Pg 111 97 00 24 MP 1x2 GDT+180V-Ad-Ad ST 87 97 10 25 MP RK 5V-Ad-Ad 114 97 00 25 MP 2x2 GDT+5V-Ad-Pg ST 88 97 10 26 MP RK 12V-Ad-Ad 114 97 00 26 MP 2x2 GDT+12V-Ad-Pg ST 88 97 10 27 MP RK 24V-Ad-Ad 114 97 00 27 MP 2x2 GDT+24V-Ad-Pg ST 88 97 10 28 MP RK 36V-Ad-Ad 114 97 00 28 MP 2x2 GDT+36V-Ad-Pg ST 88 97 10 29 MP RK 48V-Ad-Ad 115 97 00 29 MP 2x2 GDT+48V-Ad-Pg ST 89 97 10 30 MP RK 60V-Ad-Ad 115 97 00 30 MP 2x2 GDT+60V-Ad-Pg ST 89 97 10 31 MP RK 180V-Ad-Ad 115 97 00 31 MP 2x2 GDT+180V-Ad-Pg ST 89 97 10 32 MP RK 5V-Ad-Pg 116 97 00 32 MP 1x2 GDT+5V-Ad-Pg ST 90 97 10 33 MP RK 12V-Ad-Pg 117 97 00 33 MP 1x2 GDT+12V-Ad-Pg ST 90 97 10 34 MP RK 24V-Ad-Pg 118 97 00 34 MP 1x2 GDT+24V-Ad-Pg ST 90 97 10 35 MP RK 36V-Ad-Pg 118 97 00 35 MP 1x2 GDT+36V-Ad-Pg ST 90 97 10 36 MP RK 48V-Ad-Pg 117 97 00 36 MP 1x2 GDT+48V-Ad-Pg ST 91 97 10 37 MP RK 60V-Ad-Pg 117 97 00 37 MP 1x2 GDT+60V-Ad-Pg ST 91 97 10 38 MP RK 180V-Ad-Pg 117 97 00 38 MP 1x2 GDT+180V-Ad-Pg ST 91 97 10 39 MP RK 5V-Ad-Ad-Pg 118 97 00 39 MP 2x2 GDT+5V-Ad-Ad-Pg ST 92 97 10 40 MP RK 12V-Ad-Ad-Pg 118 97 00 40 MP 2x2 GDT+12V-Ad-Ad-Pg ST 92 97 10 41 MP RK 24V-Ad-Ad-Pg 118 97 00 41 MP 2x2 GDT+24V-Ad-Ad-Pg ST 92 97 10 42 MP RK 36V-Ad-Ad-Pg 118 97 00 42 MP 2x2 GDT+36V-Ad-Ad-Pg ST 92 97 10 43 MP RK 48V-Ad-Ad-Pg 119 97 00 43 MP 2x2 GDT+48V-Ad-Ad-Pg ST 93 97 10 44 MP RK 60V-Ad-Ad-Pg 119 97 00 44 MP 2x2 GDT+60V-Ad-Ad-Pg ST 93 97 10 45 MP RK 180V-Ad-Ad-Pg 119 97 00 45 MP 2x2 GDT+180V-Ad-Ad-Pg ST 93 97 10 50 MP 2x2 5V-HF ST 98 106 97 00 46 MP 1x2 GDT+5V-Ad-Ad-Pg ST 94 97 10 51 MP 2x2 24V-HF ST 98 97 00 47 MP 1x2 GDT+12V-Ad-Ad-Pg ST 94 97 10 52 MP 1x2 5V-HF ST 99 97 00 48 MP 1x2 GDT+24V-Ad-Ad-Pg ST 94 97 10 53 MP 1x2 24V-HF ST 99 97 00 49 MP 1x2 GDT+36V-Ad-Ad-Pg ST 94 97 00 50 MP 1x2 GDT+48V-Ad-Ad-Pg ST 95 97 00 51 MP 1x2 GDT+60V-Ad-Ad-Pg ST 95 97 00 52 MP 1x2 GDT+180V-Ad-Ad-Pg ST 97 10 03 MP RK GDT 230 Page 95 102 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Product Register Alphabetical Product nameItem no. Page Product nameItem no. Page Product nameItem no. Page 96 00 53 39 CT-T2/3+1-275 96 00 42 30 A46 87 01 00 199 CT-T2/1+0-275-FM AntPro 5,8GHz-R-SMA 04 58 02 161 CT-T2/1+0-275-VA 96 01 36 47 CT-T2/3+1-275-FM 96 00 43 30 AntPro 5,8GHz-SMA 04 58 00 161 CT-T2/1+0-275-VA-FM 96 01 37 47 CT-T2/3+1-275-VA 96 01 26 43 AntPro Koax-GSM-N/230 04 00 01 162 CT-T2/1+0-350 96 00 66 39 CT-T2/3+1-275-VA-FM 96 01 27 43 AntPro Koax-GSM-N-230(f/f) 04 00 04 162 CT-T2/1+0-350-FM 96 00 67 39 CT-T2/3+1-350 96 00 56 31 AntPro Lambda 7/16 0.42GHz 04 04 25 169 CT-T2/1+0-350-VA 96 01 50 47 CT-T2/3+1-350-FM 96 00 57 31 AntPro Lambda/4 7/16 TRI 04 00 30 167 CT-T2/1+0-350-VA-FM 96 01 51 47 CT-T2/3+1-350-VA 96 01 40 43 AntPro Lambda/4 7/16 TRI (f/f) 04 00 31 168 CT-T2/1+0-440 96 00 80 39 CT-T2/3+1-350-VA-FM 96 01 41 43 AntPro Lambda/4 N 0.51GHz 04 00 20 163 CT-T2/1+0-440-FM 96 00 81 39 CT-T2/3+1-440 96 00 70 31 AntPro Lambda/4 N 0.51GHz (f/f) 04 00 21 164 CT-T2/1+0-600 96 00 94 39 CT-T2/3+1-440-FM 96 00 71 31 AntPro Lambda/4 N 0.8GHz 04 00 22 163 CT-T2/1+0-600-FM 96 00 95 39 CT-T2/4+0-150 96 00 40 28 AntPro Lambda/4 N 2.0GHz 04 00 23 163 CT-T2/1+0-75 96 00 24 38 CT-T2/4+0-150-FM 96 00 41 28 AntPro Lambda/4 N 2.0GHz (f/f) 04 00 24 164 CT-T2/1+0-75-FM 96 00 25 38 CT-T2/4+0-275 96 00 54 28 CPS+ 230 32 50 00 53 CT-T2/1+1-150 96 00 36 36 CT-T2/4+0-275-FM 96 00 55 28 CPS+ 230SAT 32 50 02 53 CT-T2/1+1-150-FM 96 00 37 36 CT-T2/4+0-275-VA 96 01 38 42 CPS+ 230Tel/Net 32 50 01 53 CT-T2/1+1-275 96 00 50 36 CT-T2/4+0-275-VA-FM 96 01 39 42 96 00 51 36 CT-T2/4+0-350 96 00 68 29 CPS+ 230TV 32 50 03 53 CT-T2/1+1-275-FM CT PV-T2/2+1/1000 96 02 26 63 CT-T2/1+1-275-VA 96 01 34 46 CT-T2/4+0-350-FM 96 00 69 29 CT PV-T2/2+1/1000-FM 96 02 27 63 CT-T2/1+1-275-VA-FM 96 01 35 46 CT-T2/4+0-350-VA 96 01 52 42 CT PV-T2/2+1/600 96 02 24 63 CT-T2/1+1-350 96 00 64 37 CT-T2/4+0-350-VA-FM 96 01 53 42 CT PV-T2/2+1/600-FM 96 02 25 63 CT-T2/1+1-350-FM 96 00 65 37 CT-T2/4+0-440 96 00 82 29 CT PV-T2/2+GDT/1000 96 03 00 64 CT-T2/1+1-350-VA 96 01 48 46 CT-T2/4+0-440-FM 96 00 83 29 CT PV-T2/2+GDT/1000-FM 96 03 01 64 CT-T2/1+1-350-VA-FM 96 01 49 46 CT-T2-150-M 96 01 83 39 CT PV-T2/2+GDT/600 96 02 28 64 CT-T2/1+1-440 96 00 78 37 CT-T2-275-M 96 01 84 33 CT PV-T2/2+GDT/600-FM 96 02 29 64 CT-T2/1+1-440-FM 96 00 79 37 CT-T2-275-VA-M 96 01 96 42 CT PV-T2/2-0/1000 96 02 22 62 CT-T2/2+0-150 96 00 34 34 CT-T2-350-M 96 01 85 31 CT PV-T2/2-0/1000-FM 96 02 23 62 CT-T2/2+0-150-FM 96 00 35 34 CT-T2-350-VA-M 96 01 97 42 CT PV-T2/2-0/600 96 02 20 62 CT-T2/2+0-275 96 00 48 34 CT-T2-NPE-M 96 02 39 31 CT PV-T2/2-0/600-FM 96 02 21 62 CT-T2/2+0-275-FM 96 00 49 34 CT-T3/Y1-120 96 01 98 51 CT PV-T2-1000-M 96 02 47 62 CT-T2/2+0-275-VA 96 01 32 45 CT-T3/Y1-120-FM 96 01 99 51 CT PV-T2-600-M 96 02 46 62 CT-T2/2+0-275-VA-FM 96 01 33 45 CT-T3/Y1-230 96 02 02 51 CT PV-T2-GDT-M 96 02 48 64 CT-T2/2+0-350 96 00 62 35 CT-T3/Y1-230-FM 96 02 03 51 96 02 44 51 CT-T1/0+1-FS-FM 96 02 33 17 CT-T2/2+0-350-FM 96 00 63 35 CT-T3/Y1-230-M CT-T1/1+0-350-FM 96 02 17 16 CT-T2/2+0-350-VA 96 01 46 45 CT-T3/Y1-24 96 01 86 50 CT-T1/1+1-350-FM 96 02 15 15 CT-T2/2+0-350-VA-FM 96 01 47 45 CT-T3/Y1-24-FM 96 01 87 50 CT-T1/2+0-350-FM 96 02 13 14 CT-T2/2+0-440 96 00 76 35 CT-T3/Y1-24-M 96 02 40 51 CT-T1/3+0-350-FM 96 02 09 13 CT-T2/2+0-440-FM 96 00 77 35 CT-T3/Y1-48 96 01 90 50 CT-T1/3+1-350-FM 96 02 07 12 CT-T2/3+0-150 96 00 30 32 CT-T3/Y1-48-FM 96 01 91 50 CT-T1+2/1+0-350-FM 96 00 11 24 CT-T2/3+0-150-FM 96 00 31 32 CT-T3/Y1-60 96 01 94 51 CT-T1+2/1+1-350-FM 96 00 09 23 CT-T2/3+0-275 96 00 44 32 CT-T3/Y1-60-FM 96 01 95 51 CT-T1+2/2+0-350-FM 96 00 07 22 CT-T2/3+0-275-FM 96 00 45 32 CT-T3/Y3-230 96 02 04 52 CT-T1+2/3+0-350-FM 96 00 03 21 CT-T2/3+0-275-VA 96 01 28 44 CT-T3/Y3-230-FM 96 02 05 52 CT-T1+2/3+1-350-FM 96 00 01 20 CT-T2/3+0-275-VA-FM 96 01 29 44 CT-T3/Y3-230-M 96 02 45 52 CT-T1+2-350-M 96 02 36 20 CT-T2/3+0-350 96 00 58 33 DAK 2x 16 17 01 10 60 CT-T1-350-M 96 02 37 12 CT-T2/3+0-350-FM 96 00 59 33 DataPro ISDN-aP 24 00 13 130 CT-T1-NPE-M 96 02 38 12 CT-T2/3+0-350-VA 96 01 42 44 DataPro Koax-8V-BNC 54 43 46 159 CT-T2/0+1-FS 96 02 34 40 CT-T2/3+0-350-VA-FM 96 01 43 44 DataPro Koax-8V-BNC-75 Ohm 54 43 40 159 CT-T2/0+1-FS-FM 96 02 35 40 CT-T2/3+0-440 96 00 72 33 DataPro-Radio/TV 21 00 30 158 CT-T2/1+0-150 96 00 38 38 CT-T2/3+0-440-FM 96 00 73 33 DataPro-SAT 21 00 20 158 CT-T2/1+0-150-FM 96 00 39 39 CT-T2/3+1-150 96 00 28 30 DataPro-TAE/NFN-aP 24 00 04 131 CT-T2/1+0-275 96 00 52 39 CT-T2/3+1-150-FM 96 00 29 30 DP 10LSA-110 24 01 40 147 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 231 Product Register Alphabetical Product nameItem no. 232 Page Product nameItem no. Page Product nameItem no. Page 27 04 04 184 LSA 2/10-ER38-rot 24 01 04 151 DP 10LSA-12V 24 00 25 147 DP2x1-150V/150V-Tr DP 10LSA-24V 24 00 27 147 DP2x1-15V/15V-Tr 27 15 15 183 LSA 2/10-ES 24 01 33 152 DP 10LSA-PTC 110 24 01 42 148 DP2x1-24V/24V-Tr 27 24 24 183 LSA 2/10-MW10-25/22 24 01 10 152 DP 10LSA-PTC-12V 24 00 26 148 DP2x1-30V/30V-Tr 27 30 30 184 LSA 2/10-TR 24 01 02 150 DP 10LSA-PTC-24V 24 00 28 148 DP2x1-36V/36V-Tr 27 36 36 184 LSA DIN ADAPT 24 01 37 152 DP 1LSA-110 24 00 39 139 DP2x1-48V/48V-Tr 27 48 48 184 LSA-Anlegewerkzeug 24 01 12 152 DP 1LSA-110-PTC 24 00 46 141 DP2x1-60V/60V-Tr 27 60 60 184 MP 1x2 24V-HF ST 97 10 53 99 DP 1LSA-12 24 00 32 138 DP2x1-6V/6V-Tr 27 06 06 183 MP 1x2 5V-HF ST 97 10 52 99 DP 1LSA-12-PTC 24 00 41 140 DP2x1-80V/80V-Tr 27 80 80 184 MP 1x2 GDT ST 97 00 10 81 DP 1LSA-15 24 00 33 138 DP3x1-12V/12V-Tr 28 12 12 185 MP 1x2 GDT+12V-Ad-Ad ST 97 00 19 86 DP 1LSA-15-PTC 24 00 42 140 DP3x1-150V/150V-Tr 28 04 04 186 MP 1x2 GDT+12V-Ad-Ad-Pg ST 97 00 47 94 DP 1LSA-180FS 24 00 47 142 DP3x1-15V/15V-Tr 28 15 15 185 MP 1x2 GDT+12V-Ad-Pg ST 97 00 33 90 DP 1LSA-24 24 00 34 138 DP3x1-24V/24V-Tr 28 24 24 185 MP 1x2 GDT+180V-Ad-Ad ST 97 00 24 87 DP 1LSA-24-PTC 24 00 43 140 DP3x1-30V/30V-Tr 28 30 30 185 MP 1x2 GDT+180V-Ad-Ad-Pg ST 97 00 52 95 DP 1LSA-30 24 00 36 139 DP3x1-36V/36V-Tr 28 36 36 186 MP 1x2 GDT+180V-Ad-Pg ST 97 00 38 91 DP 1LSA-48 24 00 37 139 DP3x1-48V/48V-Tr 28 48 48 186 MP 1x2 GDT+24V-Ad-Ad ST 97 00 20 86 28 60 60 186 MP 1x2 GDT+24V-Ad-Ad-Pg ST 97 00 48 94 DP 1LSA-48-PTC 24 00 44 141 DP3x1-60/60V-Tr DP 1LSA-5 24 00 31 138 EnerPro 230 SDU 24 00 02 57 MP 1x2 GDT+24V-Ad-Pg ST 97 00 34 90 DP 1LSA-5-PTC 24 00 40 140 EP D 230 KM 36 20 35 55 MP 1x2 GDT+36V-Ad-Ad ST 97 00 21 86 DP 1LSA-60 24 00 38 139 EP D 230 SM 36 20 30 54 MP 1x2 GDT+36V-Ad-Ad-Pg ST 97 00 49 94 DP 1LSA-60-PTC 24 00 45 141 EPF 230/400V/100A-E 25 31 40 180 MP 1x2 GDT+36V-Ad-Pg ST 97 00 35 90 DP 1LSA-C12FS-PTC 24 00 64 145 EPF 230/400V/16A-W 25 30 45 179 MP 1x2 GDT+48V-Ad-Ad ST 97 00 22 87 DP 1LSA-C15FS-PTC 24 00 65 145 EPF 230/400V/200A-E 25 31 60 180 MP 1x2 GDT+48V-Ad-Ad-Pg ST 97 00 50 95 DP 1LSA-C24FS-PTC 24 00 66 145 EPF 230/400V/25A-W 25 30 80 179 MP 1x2 GDT+48V-Ad-Pg ST 97 00 36 91 DP 1LSA-C48FS-PTC 24 00 61 146 EPF 230/400V/35A-W 25 31 00 179 MP 1x2 GDT+5V-Ad-Ad ST 97 00 18 86 DP 1LSA-C5FS-PTC 24 00 63 145 EPF 230/400V/63A-E 25 31 30 180 MP 1x2 GDT+5V-Ad-Ad-Pg ST 97 00 46 94 DP 1LSA-C60FS-PTC 24 00 62 146 EPF 230V/16A-S 25 30 20 177 MP 1x2 GDT+5V-Ad-Pg ST 97 00 32 90 DP 1LSA-T110FS-PTC 24 00 48 143 EPF 230V/16A-Tr 25 30 16 176 MP 1x2 GDT+60V-Ad-Ad ST 97 00 23 87 DP 1LSA-TK180FS 24 00 49 144 EPF 230V/16A-W 25 30 25 178 MP 1x2 GDT+60V-Ad-Ad-Pg ST 97 00 51 95 DP 1x8RJ45-19“ 19 40 13 128 EPF 230V/25A-Tr 25 30 17 176 MP 1x2 GDT+60V-Ad-Pg ST 97 00 37 91 DP 1xRJ45-PoE-Alu 24 00 21 126 EPF 230V/35A-S 25 30 85 177 MP 2x2 24V-HF ST 97 10 51 98 DP 2x1-12V/12V-0,3Ω -Tr 26 12 12 187 EPF 48V/25A-S 25 30 53 177 MP 2x2 5V-HF ST 97 10 50 98 97 00 07 80 DP 2x1-24V/24V-0,3Ω -Tr 26 24 24 187 EPF 60V/16A-S 25 30 22 177 MP 2x2 GDT ST DP 2x1-30V/30V-0,3Ω-Tr 26 30 30 187 H35 87 00 10 197 MP 2x2 GDT+12V-Ad-Ad ST 97 00 12 84 DP 2x1-36V/36V-0,3Ω -Tr 26 36 36 187 H45 16 02 00 198 MP 2x2 GDT+12V-Ad-Ad-Pg ST 97 00 40 92 DP 2x1-RLC/50V-Tr 28 70 50 188 H65 87 01 50 196 MP 2x2 GDT+12V-Ad-Pg ST 97 00 26 88 DP 2x1-RLC-Tr 27 00 00 189 IF1 82 30 11 211 MP 2x2 GDT+180V-Ad-Ad ST 97 00 17 85 DP 2x8RJ45-19“ 19 40 23 128 IF3 82 30 16 211 MP 2x2 GDT+180V-Ad-Ad-Pg ST 97 00 45 93 DP 3x8RJ45-19“ 19 40 33 128 IsoProData 150V/150V-Tr 27 03 03 182 MP 2x2 GDT+180V-Ad-Pg ST 97 00 31 89 DP 4x8RJ45-19‘‘ 19 40 43 129 IsoProData-Tr 27 30 02 103 MP 2x2 GDT+24V-Ad-Ad ST 97 00 13 84 DP 5x8RJ45-19“ 19 40 53 129 K1/150 49 51 06 211 MP 2x2 GDT+24V-Ad-Ad-Pg ST 97 00 41 92 DP 6x8RJ45-19“ 19 40 63 129 K1/300 49 51 08 211 MP 2x2 GDT+24V-Ad-Pg ST 97 00 27 88 DP 8xRJ45-6V-WG 19 40 50 127 KA1/2 17 00 10 67 MP 2x2 GDT+36V-Ad-Ad ST 97 00 14 84 DP Koax BNC 50Ohm 54 43 30 160 KA1/4 17 00 20 67 MP 2x2 GDT+36V-Ad-Ad-Pg ST 97 00 42 92 DP FME-AD 16 05 20 170 KA1/6 17 00 30 67 MP 2x2 GDT+36V-Ad-Pg ST 97 00 28 88 DP Koax 7/16 10 10 00 165 KA1/8 17 00 40 67 MP 2x2 GDT+48V-Ad-Ad ST 97 00 15 85 DP Koax 7/16 (f/f) 10 10 01 166 LC 1 87 00 05 200 MP 2x2 GDT+48V-Ad-Ad-Pg ST 97 00 43 93 DP RJ45 f/f 24 00 11 125 LSA 2/10 AD 24 01 09 152 MP 2x2 GDT+48V-Ad-Pg ST 97 00 29 89 DP RJ45-CAT6-48V-Tr 24 00 05 124 LSA 2/10 KS-120 24 01 36 152 MP 2x2 GDT+5V-Ad-Ad ST 97 00 11 84 DP2-2MB-Tr 24 00 17 190 LSA 2/10 KSR 24 01 08 152 MP 2x2 GDT+5V-Ad-Ad-Pg ST 97 00 39 92 DP2x1-12V/12V-Tr 27 12 12 183 LSA 2/10-AN 24 01 00 149 MP 2x2 GDT+5V-Ad-Pg ST 97 00 25 88 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de Product Register Alphabetical Product nameItem no. Page Product nameItem no. Page MP 2x2 GDT+60V-Ad-Ad ST 97 00 16 85 PLPro-40A-iV MP 2x2 GDT+60V-Ad-Ad-Pg ST 97 00 44 93 PLPro-80A-iV 55 04 41 218 MP 2x2 GDT+60V-Ad-Pg ST 97 00 30 89 PP PV 1000 37 44 02 61 MP Base 2x2 97 00 03 81 PP PV 1000/FM 37 44 03 61 MP Base 2x2 GDT 97 00 04 81 PP PV 800 37 44 00 60 MP Base 2x2-R 97 00 00 85 PP PV 800/FM 37 44 01 60 MP Base 2x2-R GDT 97 00 01 85 SGO 350 47 22 13 208 MP RK 12V-Ad-Ad 97 10 26 114 SGO 350 QA 47 21 11 210 MP RK 12V-Ad-Ad-Pg 97 10 40 118 SGO 70 47 21 17 208 MP RK 12V-Ad-Pg 97 10 33 116 SGO 70 QA 47 21 04 210 MP RK 180V-Ad-Ad 97 10 31 115 TA 100 C 48 78 14 209 MP RK 180V-Ad-Ad-Pg 97 10 45 119 TA 500 C 48 78 27 209 MP RK 180V-Ad-Pg 97 10 38 117 TC 100 A 48 78 30 211 MP RK 24V-Ad-Ad 97 10 27 114 TC 500 A 48 78 50 211 MP RK 24V-Ad-Ad-Pg 97 10 41 118 TelPro LSA 2/10-2E 8x20 24 01 28 137 MP RK 24V-Ad-Pg 97 10 34 116 TelPro LSA 2/10-2E 8x6 24 01 06 135 24 01 18 136 55 04 40 218 MP RK 36V-Ad-Ad 97 10 28 114 TelPro LSA 2/10-3E 8x13 MP RK 36V-Ad-Ad-Pg 97 10 42 118 TelPro LSA 2/10-3EH230E-10kA 24 01 19 136 MP RK 36V-Ad-Pg 97 10 35 116 TelPro LSA 2EY230-20kA 24 01 29 137 MP RK 48V-Ad-Ad 97 10 29 115 TelPro LSA-2EH230-10kA 24 01 13 135 MP RK 48V-Ad-Ad-Pg 97 10 43 119 TelPro LSA-2EH230F-10kA 24 01 14 135 MP RK 48V-Ad-Pg 97 10 36 117 TelPro LSA-2EH350-10kA 24 01 16 135 MP RK 5V-Ad-Ad 97 10 25 114 TelPro LSA-2EH90-10kA 24 01 17 135 MP RK 5V-Ad-Ad-Pg 97 10 39 118 TelPro LSA-2EL230-20kA 24 01 15 135 MP RK 5V-Ad-Pg 97 10 32 116 TelPro LSA-2EY350-20kA 24 01 32 137 MP RK 60V-Ad-Ad 97 10 30 115 TelPro LSA-2EY90-20kA 24 01 31 137 MP RK 60V-Ad-Ad-Pg 97 10 44 119 TelPro LSA-3EH230F1E-10kA 24 01 23 136 MP RK 60V-Ad-Pg 97 10 37 117 TelPro LSA-3EH90E-10kA 24 01 26 136 MP RK GDT 97 10 03 102 TelPro LSA-3EH90F1E-10kA 24 01 27 136 MP RK GDT+12V-Ad-Ad 97 10 05 106 TelPro LSA-3EL230E-20kA 24 01 24 136 MP RK GDT+12V-Ad-Ad-Pg 97 10 19 110 TelPro LSA-3EL230F1E-20kA 24 01 25 136 MP RK GDT+12V-Ad-Ad-Pg 97 10 20 110 TF 100Tr/Th-Pk 53 43 72 213 MP RK GDT+12V-Ad-Pg 97 10 12 108 TF 2000Tr/Th-Pk 55 04 11 213 MP RK GDT+180V-Ad-Ad 97 10 10 107 TF 500-Tr 53 43 98 213 MP RK GDT+180V-Ad-Ad-Pg 97 10 24 111 TF 500Tr/Th-Pk 53 43 85 213 MP RK GDT+180V-Ad-Pg 97 10 17 109 TSF 100 44 90 69 206 MP RK GDT+24V-Ad-Ad 97 10 06 106 TSF 100-Tr 44 90 80 212 MP RK GDT+24V-Ad-Pg 97 10 13 108 TSF 50 SWISS 44 91 30 207 MP RK GDT+36V-Ad-Ad 97 10 07 106 TSF 500 48 78 01 206 MP RK GDT+36V-Ad-Ad-Pg 97 10 21 110 TSF 500-Tr 44 90 85 212 MP RK GDT+36V-Ad-Pg 97 10 14 108 TSF 50-Tr 44 90 76 212 MP RK GDT+48V-Ad-Ad 97 10 08 107 TSF-H1 44 91 75 206 MP RK GDT+48V-Ad-Ad-Pg 97 10 22 111 UAS 230-Tr 35 10 30 66 MP RK GDT+48V-Ad-Pg 97 10 15 109 MP RK GDT+5V-Ad-Ad 97 10 04 106 MP RK GDT+5V-Ad-Ad-Pg 97 10 18 110 MP RK GDT+5V-Ad-Pg 97 10 11 108 MP RK GDT+60V-Ad-Ad 97 10 09 107 MP RK GDT+60V-Ad-Ad-Pg 97 10 23 111 MP RK GDT+60V-Ad-Pg 97 10 16 109 NM 220V/5kA 36 05 22 56 Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 233 general terms and conditions of sale General Terms and Conditions of Sale of the Company of Leutron GmbH Effective: February 2008 I. Scope 1. Our General Terms and Conditions of Sale apply to all - including future legal relationships between the parties to the Contract. Agreements to the contrary are only valid if confirmed by us in writing. 5. We only accept drafts or cheques in payment and not in lieu of payment after separate agreement. Our account is not settled until the date on which the funds are available to us without having to make allowance for charge-back claims. Collection charges, discount charges or bill charges including interest shall in all cases be borne by the Purchaser and are payable immediately. 2. We are not bound by any contrary or contradictory General Terms and Conditions of the other party to the Contract - hereinafter referred to as the Purchaser - even if we do not expressly object to them. 6. The Purchaser may only offset against a claim which is undisputed or legally binding. He may only exercise a right of retention to the extent that his counterclaim is based on the same contractual relationship. 3. Our Terms and Conditions only reply in respect of Companies as defined in § 310 Section 1 BGB [Civil Code]. 7. One-off costs such as for example tooling and development costs are invoiced at 50% directly upon receipt of order. The remaining 50% of the said costs are due upon delivery of the first series production components. 4. Should any provision contained in our General Terms and Conditions of Sale prove to be or become invalid the validity of all remaining provisions shall not be thereby affected. II. Tender and Tender Documentation 1. Our tender is subject to confirmation in the absence of anything to the contrary ensuing from the offer. 2. We can accept orders within a period of 6 weeks. The said period commences upon receipt of order. 3. Our written Confirmation of Order is definitive in respect of supply of goods or services. Assurances regarding characteristics, supplements or ancillary agreements must be in writing to take legal effect. 4. Our sales staff are not authorised to enter into verbal ancillary agreements or to give assurances extending beyond the content of the written Contract. IV. Product Information and Design Modifications 1. The Purchaser undertakes to provide us with a comprehensive description of every aspect and detail of the conditions under which the goods supplied shall be used. 2. We reserve the right to introduce design modifications in the interests of technical progress provided the latter do not involve any changes in the function of the goods. V. Delivery Period 1. Information regarding delivery periods is unbinding unless the delivery date has been exceptionally agreed as „binding“. 5. We retain title and intellectual property rights to all diagrams, drawings, calculations and other documentation. Prior to transmission thereof to third parties the Purchaser requires our express written permission. 2. The delivery period shall commence with the date of confirmation of order but not however prior to provision of items required to be furnished by the Purchaser i.e. supporting documentation, official approvals and releases including receipt of any agreed payment, opening of any letter of credit required or evidence of arrangement of any collateral agreed. 6. In the case of series production or special custom designs we reserve the right to apply an over or under-delivery rate of 10%. The resultant over or under-delivery shall be invoiced accordingly. 3. The delivery period shall be deemed met if the goods have left the Leinfelden-Echterdingen warehouse facility within the delivery period. 7. We are entitled to make part deliveries if this may be considered reasonable for the customer. III. Prices and Terms of Payment 1. If nothing to the contrary emerges from the Confirmation of Order our prices are „ex stock“ or „ex works“ and exclusive of shipping and handling charges, customs or excise duty, packaging and are liable to the prevailing rate of statutory VAT. 2. Minimum value of goods per order is EUR 250.00 net. 234 date of invoice. Part invoices shall be presented for part deliveries. Payment terms shall run separately for each part invoice. Statutory provisions apply in the event of payment arrears. 4. Should any unforeseen impediments outside our control arise which despite the requisite care required given the particular circumstances of the case we are not in a position to avert - irrespective of whether the said impediments occur with us or at subcontractors - including force majeure (e.g. war or natural catastrophe) or delays in the supply of essential raw materials or other circumstances for which we are not responsible - we are entitled to withdraw from the Supply Contract either wholly or in part or alternatively to extend the delivery period by the duration of the impediment. We shall be entitled to the same rights in the event of strikes and lockouts at our premises or those of our upstream suppliers. We shall immediately notify our customers of any such circumstances. 3. We reserve the right to adjust our prices accordingly if subsequent to conclusion of the Contract cost reductions or cost increases, in particular as a consequence of collective wage agreements, changes in the cost of materials or currency fluctuations take place. Evidence of the above shall be made available to the Purchaser on request. 5. In the event of delay in delivery the Purchaser may, following the expiry of an appropriate period of grace to no effect, withdraw from the Contract; in the event of the practical impossibility of supply of goods on our part he is also entitled to do so without notice. A period of 14 days shall be deemed appropriate and in the case of special custom-made products this shall be a minimum of 1 month. 4. If nothing to the contrary emerges from the Confirmation of Order the net purchase price shall be due for payment (without deduction) within 8 days from Delayed delivery shall equate to impossibility if delivery does not follow after 1 month or 6 weeks in the case of special custom-made products. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de general terms and conditions of sale Claims for damages (including any consequential loss) shall be excluded irrespective of Section 6; the same shall apply in the case of reimbursement of expenses. 6. The liability disclaimer provision under Section 5 shall not apply if any exclusion or restriction of liability is agreed in respect of injury to life, physical injury or damage to health which is due to intentional or negligent dereliction of duty on the part of the user or intentional or negligent dereliction of duty on the part of any legal representative or vicarious agent of the user; nor shall it apply if any exclusion or limitation of liability is agreed for other forms of damage caused by any intentional or grossly negligent dereliction of duty on the part of any legal representative or vicarious agent of the user. If we culpably infringe any essential contractual obligation or any cardinal obligation liability shall not be excluded but shall be limited to typical foreseeable contractual damage. In the event of reimbursement of expenses the above shall apply accordingly. 7. If any commercial fixed date transaction has been agreed the liability limitations arising from Sections 5 and Section 6 shall not apply; the same applies if the Purchaser is in a position to claim that as a consequence of the delay for which we are responsible his interest in performance of the Contract ceases to apply. 8. In the case of call orders calls shall be notified to us in a timely manner to enable orderly manufacture and supply and at least 6 weeks prior to the desired delivery date. Call orders must be called forward within 12 months from the date of order if no other fixed deadlines have been agreed. If call does not follow or not completely within 12 months from the date of order or on the agreed call terms the Purchaser shall be deemed in default of acceptance. 9. Should the Purchaser fall into acceptance arrears or infringe duties of cooperation we are entitled to claim compensation for loss incurred by us including any additional expenses. In such event risk of accidental destruction or loss or accidental deterioration of the item of purchase shall transfer to the Purchaser if the latter is in default of acceptance. VI. Transfer of Risk, Packaging Costs and Insurance 1. Upon handover to the forwarding agent or carrier and at the latest upon leaving our premises risk of accidental destruction or loss and accidental deterioration transfers to the Purchaser. Incoterms 2000 „ex works/ab Werk“ Clause (German version) applies. 2. Should handover be delayed due to any circumstance for which the Purchaser is responsible or as a consequence of the latter‘s instructions risk shall transfer to the Purchaser with effect from the date of notification of readiness for despatch. At the express written request of the Purchaser we undertake to insure goods stored with us at the Purchaser‘s cost. This also applies in those cases where a delivery period has not been expressly agreed with the proviso that risk transfers to the Purchaser 7 calendar days following notification of readiness for despatch. 3. If the Purchaser wishes we shall cover delivery by transport insurance; costs in this regard shall be borne by the Purchaser. 4. Transportation and all other packaging shall not be returned subject to requirements of the German Packaging Ordinance. Pallets are excluded. The Purchaser undertakes to arrange disposal of packaging materials at his own cost. 5. Delivered items shall be received and accepted by the Purchaser even if they display minor imperfections irrespective of his rights under the terms of §§ 433 ff. BGB. VII. Reservation of Title 1. Up to the point of full settlement of the purchase price including all subsidiary claims and prior to settlement of all other claims arising from the business association goods delivered shall remain our property. Up until that point the Purchaser is not entitled to pledge the goods to third parties or to assign them as security. The Purchaser shall store the reserved goods for us at no charge. 2. In the event of processing and combination of reserved title goods with other goods by the Purchaser we shall acquire joint title to the new item in the ratio of the invoiced value of the reserved title goods to the combined material entity. The joint title rights accordingly ensuing shall be considered as reserved title goods as defined in Clause 1. 3.The Purchaser is entitled to sell the reserved title goods in the due process of sale provided he is not in payment arrears in respect of our purchase price claims. 4. The Purchaser hereby assigns to us at this point in time all claims accruing to him as a result of resale of the reserved title goods vis-à-vis third parties. If the reserved title goods are sold following processing, combination or amalgamation assignment of the claim arising from resale shall apply only up to the extent of the value of the reserved title goods invoiced to the Purchaser by the Vendor. This shall also apply if the reserved title goods are resold together with other goods which similarly do not belong to the Vendor. 5. The Purchaser is also authorised to collect the claim even following assignment. We may restrict the said collection authorisation on the basis of justifiable interest or revoke the same on due cause found, in particular in the event of payment arrears. We may require that the Purchaser shall notify us of the claims assigned to him and of related debtors plus all information necessary for collection and surrender to us all associated documentation and disclose the said assignment to his debtors. 6. We undertake to release the securities due to us on the basis of the above provisions at our discretion upon the Purchaser‘s request to the extent that their realisable value exceeds the claim secured by 20% or more. 7. The Purchaser hereby declares his consent that the persons authorised by us in connection with assignment of the reserved title goods may enter the property or building on or in which the items are situated in order to take possession of the reserved title goods. 8. The Purchaser shall immediately inform us in respect of any confiscation, compulsory enforcement or other third party intervention adversely affecting our rights of ownership. The Purchaser shall bear the costs of measures to remedy third party interference in particular of any possible intervention procedures. VIII. Guarantee and Liability 1. Should there be any defect for which we are responsible we are entitled to decide between rectification and replacement at our own discretion. A precondition in such an event is that the defect is not immaterial. In the event of rectification we undertake to bear the costs of transportation, labour and materials provided these are not increased due to the fact that the goods supplied have not been moved to a location other than the place of performance. Should one of or both forms of remedy prove impossible or disproportionate we are entitled to refuse it. We may refuse to effect a remedy for as long as the Purchaser fails to meet his payment obligations towards us to an extent equating to the fault-free portion of the goods or services. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 235 general terms and conditions of sale 2. Should rectification or replacement fail to be made within an appropriate period - with due consideration of our supply options - or if rectification and and/or replacement should fail the Purchaser may demand a reduction of remuneration (abatement) or withdraw from the Contract. 3. The Purchaser‘s rights in the event of defect assume that the latter has met his obligation under § 377 HGB [Civil Code] to inspect and submit complaints upon receipt of the goods in a timely manner. 4. If nothing to the contrary emerges under Section 6 below further claims on the part of the Purchaser, irrespective of legal grounds (in particular claims arising from infringement of main and ancillary contractual obligations, reimbursement of expenses with the exception of those defined in § 439 II BGB, impermissible act and any other tortious liability) are excluded; this applies in particular to damage not occurring to the item supplied itself including compensation claims for lost profit; also included are claims which do not result from the faulty nature of the purchased item. 10. Contract work completed by us on the basis of drawings, sketches or other information provided to us is carried out at the Purchaser´s risk in respect of patent, pattern and trademark legislation. If execution of such orders involves infringement of third party industrial property rights the Purchaser shall bear the cost of all damages incurred by us. IX. Liability for Collateral Obligations If through any fault on our part the item supplied cannot be used as stated under the terms of the Contract or if damage occurs as a consequence of omitted or faulty implementation of suggestions and consultations prior to and subsequent to conclusion of the Contract including other contractual collateral obligations to the exclusion of further claims on the part of the Purchaser the provisions of Clauses VIII and X shall apply accordingly. X. Withdrawal by the Purchaser and other Liabilities on our part 5. The above provisions also apply in the case of delivery of another item or a lesser quantity. 6. The liability disclaimer provision under Section 4 shall not apply if any exclusion or restriction of liability agreed for injury to life, physical injury or damage to health is due to intentional or negligent dereliction of duty on the part of the user or intentional or negligent dereliction of duty on the part of any legal representative or vicarious agent of the user; nor shall it apply if any exclusion or limitation of liability is agreed for other forms of damage caused by any intentional or grossly negligent dereliction of duty on the part of any legal representative or vicarious agent of the user. If we culpably infringe any essential contractual obligation or any „cardinal“ obligation liability shall not be excluded but shall be limited to typical foreseeable contractual damage; in other respects it is excluded under Section 4. The liability disclaimer additionally does not apply in those cases where under product liability legislation in the event of defects in the goods supplied there is liability in the case of personal injury or damage to property relating to privately used items. Nor does it apply in the case of assumption of a guarantee and assurance of a characteristic feature if a defect covered thereby activates our liability. In the event of reimbursement of expenses the above shall apply accordingly. 7. No guarantee is assumed in the event of damage attributable to inappropriate use, faulty assembly by the Purchaser or third parties, natural wear and tear, incorrect or negligent treatment, improper modifications carried out without our prior consent or servicing work by the Purchaser or third parties. 8. Claims for remedy, damages and replacement use shall be time-barred one year from the date of purchase of the item concerned. This does not apply to any item used in accordance with its customary purpose for a building and has caused faultiness in the latter in which case time-barring is after 5 years. Claims for abatement of price and exercise of any right of withdrawal are excluded if the claim for remedy is time-barred. In the event of operation of Sentence 3 however the Purchaser may only refuse payment of the purchase price to the extent that he would be entitled to do so as a consequence of withdrawal or abatement; in the event of withdrawal exclusion and subsequent payment refusal we are entitled to withdraw from the Contract. 9. Claims arising from manufacturer redress remain unaffected by this Section. 236 1. The following provisions shall apply in the event of infringements over and above liability for defect and shall neither exclude nor limit statutory right of withdrawal. Similarly, lawful or contractual claims due to us shall be neither excluded nor limited. 2. The Purchaser may withdraw from the Contract if the overall performance is definitively impractical, the same applying to incapacity. The Purchaser may also withdraw from the entire Contract if in the event of an order for similar items implementation of part of the supply is impossible in terms of numerical quantity due to our representation obligation and if he has no interest in partial supply; if this is not the case the Purchaser may abate the consideration accordingly; the right of withdrawal shall not apply in the case of immaterial infringement of obligation. 3. Should there be any delay in performance and provided the Purchaser grants us an appropriate period to complete performance following justification of the delay and should the said period fail to be observed the Purchaser shall be entitled to withdraw. In the event of partial delay in performance Section 1 Sentence 2 shall apply accordingly. If prior to delivery the Purchaser requires in any aspect alternative execution of the item supplied the delivery period shall be interrupted until the date of agreement regarding execution and if necessary extended by the time necessary for alternative execution. 4. Withdrawal shall be excluded if the Purchaser is solely or to a large extent predominantly responsible for the circumstance entitling him to withdrawal or if the circumstance for which we are responsible occurs at the point in time of default in acceptance on the part of the Purchaser. In the event of impracticality we retain in the above cases our claim to consideration as defined in § 326 Section 2 BGB [Civil Code]. 5. Further claims on the part of the Purchaser, irrespective of legal grounds (in particular claims arising from default at the point of conclusion of the Contract, infringement of main and ancillary contractual obligations, reimbursement of expenses, impermissible act and any other tortious liability) are excluded; this applies in particular to damage not occurring to the item supplied itself including compensation claims for lost profit; also included are claims which do not result from the faulty nature of the purchased item. This shall not apply if the cause of damage is due to intent or gross negligence on our part, our legal representatives or vicarious agents. Nor shall this apply if the damage arises from culpable injury to life, physical injury or damage to health. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de To a similarly lesser degree liability in the event of assumption of a guarantee is excluded if an obligation infringement covered thereby activates our liability. If we culpably infringe any essential contractual obligation or any „cardinal“ obligation liability shall not be excluded but shall be limited to typical foreseeable contractual damage. XI. Place of Performance and Jurisdiction 1. Place of performance of both parts arising from all legal relationships is 70771 Leinfelden-Echterdingen. 2. In respect of the legal relationship between the Purchaser and us the laws of the Federal Republic of German apply. UN Sale of Goods legislation (CISG) is expressly excluded. 3. Legal venue for all disputes arising form the contractual relationship is Leinfelden-Echterdingen. We are also entitled to file an action at the domicile of the Purchaser. Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de 237 Surge protection for power supply systems Surge protection for measuring systems and automatic control devices Surge protection for information technology and telecommunication Surge protection for transmitting and receiving systems EMC filter with integrated surge protection Monitoring Rare-gas-filled insulation spark gaps Leutron GmbH lightning and surge Protection Humboldtstrasse 30/32 D-70771 Leinfelden-Echterdingen germany Phone:+49-(0)711-94771-0 Fax:+49-(0)711-94771-70 [email protected] www.leutron.de www.LEUTRON.DE Protective devices for AC arresting
Similar documents
Short Form Catalogue 2016
Multi-pole lightning current arrester type 1 (class I) for 3-phase TN-S systems. The arresters can be installed at the transition 0A to 1 accord-ing to the lightning protection zones concept. The S...
More informationWWW .Leutron .de - El
Surge protection for measuring systems and automatic control devices Pluggable SPD with high discharge cappability for MCR applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
More information