Grundfos Basic Databook 13072KB Feb 18 2013 10:33:57 AM

Transcription

Grundfos Basic Databook 13072KB Feb 18 2013 10:33:57 AM
GRUNDFOS DATA BOOKLET
Grundfos Basic
50 Hz
Contents
JPBasic
Performance range
General data
Applications
Constructional features
Material specification
Technical data
Curve conditions
CHBasic PS
Page
Page
Page
Page
Page
Page
Page
3
4
4
4
5
5
5
Page
Page
Page
Page
Page
10
10
10
10
11
Page
12
JPBasic PS
General data
JPBasic PC
General data
Applications
Operation
Technical data
Page
Page
Page
Page
13
13
13
15
Page
Page
Page
Page
Page
Page
16
16
16
16
17
18
Page
Page
Page
Page
Page
Page
Page
19
20
20
20
20
21
21
Page
Page
Page
Page
Page
Page
24
24
24
24
25
25
JDBasic
General data
Applications
Constructional features
Material specification
Technical data
Instructions for conversion
CHBasic
Performance range
General data
Applications
Constructional features
Material specification
Technical data
Curve conditions
CHBasic PT
General data
Applications
Constructional features
Material specification
Technical data
Curve conditions
2
Page
Page
Page
Page
Page
Page
26
26
26
26
27
27
Page
Page
Page
Page
Page
Page
Page
28
28
28
28
29
30
30
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
31
32
32
32
32
32
33
35
35
35
35
36
Page
Page
Page
Page
Page
Page
39
40
40
40
41
41
Page
Page
Page
Page
Page
Page
44
45
45
45
45
46
Page
Page
Page
Page
Page
47
47
47
47
48
CHBasic PC
JPBasic PT
General data
Applications
Constructional features
Material specification
Technical data
General data
Applications
Constructional features
Material specification
Technical data
Curve conditions
General data
Applications
Operation
Constructional features
Material specification
Technical data
Curve conditions
NSBasic
Performance range
General data
NSBasic single impeller pumps
Applications
Constructional features
Material specification
Technical data
NSBasic twin impeller pumps
Applications
Constructional features
Material specification
Technical data
KPBasic
Performance range
General data
Applications
Constructional features
Technical data
Curve conditions
PFBasic
Performance range
General data
Applications
Constructional features
Material specification
Technical data
PFPBasic
General data
Applications
Constructional features
Materials
Technical data
JPBasic
JPBasic
Performance range
p
[kPa]
H
[m]
JPBasic
65
600
50 Hz
60
55
500
50
45
400
40
5
35
300
200
7
30
10
25
4
20
3
9
15
2
100
10
5
0
0
0.0
1
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
2.5
10
Q [m³/h]
3.0
Q [l/s]
TM02 8936 1804
0
3
JPBasic
General data
JPBasic 9, JPBasic 10
Applications
Gr7921
Gr7903
JPBasic 2, JPBasic 3, JPBasic 4
JPBasic 5, JPBasic 7
Self-priming centrifugal pump with excellent suction
capacity even when there are air bubbles and small
sandy impurities in the water.
Used especially for supplying water to domestic
systems. Ideal for use in small-scale agriculture and
gardening, limited industrial services and wherever selfpriming operation is necessary.
Constructional features
Cast iron pump body and motor support in cast iron
treated against corrosion also on the inner surface.
Technopolymer impeller, diffuser venturi tube and sand
tube. Stainless steel pressure disc. Carbon/ceramic
mechanical seal mounted on stainless steel rotor shaft
extension.
Motor
Asynchronous motor cooled with external fan. Rotor
mounted on greased sealed-for-life ball bearings,
selected to ensure silent running and a long life.
Built-in thermal and current overload protection and a
capacitor permanently in circuit in the single-phase
version.
The user is responsible for protection in the three-phase
version.
Motor protection:
IP 44
Terminal box protection: IP 55
Insulation class:
F
Standard voltage:
1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
4
Gr7917
Pump
JPBasic
Technical data
Material specification
Description
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
AISI 303 stainless steel X 10 Cr NiS 18 9 *
8
Venturi tube and
nozzle
Noryl GFN 2
16
Mechanical seal
Carbon/Ceramic
28
O-Ring gasket
NBR
8
1
6 28
3
* JPBasic 1, JPBasic 2, JPBasic 4: X 12 Cr S 13
16
4
7
TM02 8459 0204
Pos.
Technical data
Operating range:
From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth:
8 metres
Maximum operating pressure:
JPBasic 2, JPBasic 3, JPBasic 4:
JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10:
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
6 bar (600 kPa)
7.5 bar (750 kPa)
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
5
Technical data
JPBasic
JPBasic 2
0
A
A1
P
[kPa]
400
H
[m]
240
TM02 8444 0204
G
B
Voltage [V]
1 x 220-240
JPBasic 2
P2
In
Capacitor
Max.
[kW]
[kW]
[hp]
[A]
[µF] [Vc]
3.12
12.5 450
0.72 0.44 0.6
3 x 220-240/380-415 0.67 0.44 0.6 2.1/1.2
-
JPBasic 2
10
Q [IMP GPM]
H
[ft]
100
80
20
160
60
8
15
5
6
7
4
3
2
40
10
80
20
5
0
0
0.4
0
0.8
0.2
1.2
1.6
2.0
0.4
10
2.4
Q [m³/h]
Q [l/s]
40
Q [l/min]
0.6
20
30
-
Packing dimensions
[mm]
Dimensions [mm]
Pump
type
8
Q [US GPM]
25
Electrical data
P2
6
12
120
0.0
0.0
P1
4
10
30
0
Pump type
2
8
35
H3
I
F
E
0
6
40
320
H
DNA
DNM
4
TM02 9023 1304
C
2
A
A1
B
C
E
F
G
H
H3
I
DNA
DNM
L/A
L/B
L/H
395
390
178
108
192
14
111
200
144
9
Rp 1
Rp 1
470
240
240
Vol
[m3]
Weight
[kg]
0.027
10.9
JPBasic 3
0
C
P
[kPa]
H
[m]
45
400
40
TM02 8444 0204
H3
320
I
F
E
G
B
JPBasic 3
Pump
type
JPBasic 3
6
P1
Max.
[kW]
P2
[kW]
1 x 220-240
0.85
3 x 220-240/380-415
0.86
P2
Capacitor
[hp]
[A]
[µF] [Vc]
0.6
0.8
3.8
12.5
450
0.6
0.8 2.8/1.6
-
-
4
10
6
8
12
14 Q [US GPM]
10
Q [IMP GPM]
H
[ft]
140
120
100
80
20
160
8
60
7
6
15
5
4
3
10
80
2
40
20
5
0
0
0.0
0.0
In
8
25
240
Electrical data
Voltage [V]
2
6
30
0
Pump
type
0
4
35
H
DNA
DNM
2
0.4
0
0.8
0.2
10
1.2
1.6
0.4
20
2.0
2.4
0.6
30
2.8
0.8
40
50 Q [l/min]
Packing dimensions
[mm]
Dimensions [mm]
Q [m³/h]
Q [l/s]
TM02 9024 1304
A
A1
A
A1
B
C
E
F
G
H
H3
I
DNA
DNM
L/A
L/B
L/H
395
390
178
108
192
14
111
200
144
9
Rp 1
Rp 1
470
240
240
Vol
[m3]
Weight
[kg]
0.027
11
Technical data
JPBasic
JPBasic 4
0
C
DNA
DNM
P
[kPa]
H
[m]
50
400
40
300
30
2
0
4
2
6
8
4
10
6
8
12
14 Q [US GPM]
10
Q [IMP GPM]
H
[ft]
160
H
45
140
120
I
F
E
TM02 8444 0204
H3
35
G
B
200
1 x 220-240
JPBasic 4
P2
6
100
[kW] [hp]
In
Capacitor
[A]
[µF] [Vc]
1.13 0.75
1
5.1
16
450
3 x 220-240/380-415 1.04 0.75
1
3.3/1.9
-
-
4
60
2
3
40
20
5
0
0
0.0
0.0
P2
5
10
0.4
0
0.8
0.2
1.2
10
1.6
0.4
20
2.0
2.4
0.6
30
2.8
0.8
40
Q [m³/h]
Q [l/s]
50 Q [l/min]
Packing dimensions
[mm]
Dimensions [mm]
Pump
type
JPBasic 4
P1
Max.
[kW]
7
15
Electrical data
Voltage [V]
80
8
20
0
Pump type
100
25
TM02 9025 1304
A
A1
A
A1
B
C
E
F
G
H
H3
I
DNA
DNM
L/A
L/B
L/H
414
409
178
108
197
14
111
213
144
9
Rp 1
Rp 1
470
240
240
Vol
[m3]
Weight
[kg]
0.027
16.2
JPBasic 9
0
A
4
8
12
16 20 24 28 32 36 40 44 48
Q [US GPM]
DNA
C
P
[kPa]
400
H
TM02 8464 0204
G
B
200
100
Pump
type
JPBasic 9
16
20
24
28
32
36
40
Q [IMP GPM]
H
[ft]
120
30
100
25
80
20
60
40
10
8
P2
P2
In
Max.
[kW]
[kW]
[hp]
[A]
[µF]
[Vc]
1 x 220-240
2
1.5
2
9
31.5
450
3 x 220-240/
380-415
2
1.5
2
6.8/3.9
-
-
7
5
Electrical data
JPBasic 9
12
40
6
5
4
0
0
0.0
P1
Voltage [V]
8
15
0
Pump
type
4
1
2
0.4
3
0.8
4
5
6
1.2
1.6
7
8
9
2.0
2.4
20
3
2 1
0
10 11 Q [m³/h]
2.8
Q [l/s]
TM02 9028 1304
H1
Iø
F
0
35
300
E
H
[m]
Capacitor
0
20
40
60
80
100
120
140
160
Packing dimensions
[mm]
Dimensions [mm]
A
B
C
E
F
G
Iø
H
H1
DNA
DNM
L/A
L/B
L/H
521
214
151
282
20
160
11
227
175
Rp 1 ½
Rp 1 ¼
612
248
279
180Q [l/min]
Vol
[m3]
Weight
[kg]
0.042
27
7
Technical data
JPBasic
JPBasic 10
0
A
A1
DNA
DNM
P
[kPa]
H
[m]
50
400
40
300
30
0
8
4
12
8
16 20 24 28 32 36 40 44 48
12
16
20
24
28
32
36
Q [US GPM]
40
Q [IMP GPM]
H
[ft]
160
H3
H
45
140
120
I
F
E
TM02 8464 0204
35
G
B
100
25
200
80
8
20
60
15
100
10
0
P2
P2
In
Capacitor
Max.
[kW]
[kW]
[hp]
[A]
[µF]
[Vc]
1 x 220-240
2.7
2.2
3
12
40
450
3 x 220-240/
380-415
2.7
2.2
3
8.5/4.9
-
-
Voltage [V]
JPBasic 10
JPBasic 10
2
1
20
0
0
1
2
3
0.8
0.4
20
40
4
5
6
1.2
1.6
60
80
7
8
9
2.0
2.4
100
120
140
10 11 Q [m³/h]
2.8
Q [l/s]
160
180Q [l/min]
Packing dimensions
[mm]
Dimensions [mm]
Pump
type
3
4
0
0
0.0
P1
6
5
Electrical data
Pump
type
40
7
5
A
B
C
E
F
G
IØ
H
H1
DNA
DNM
L/A
L/B
L/H
595
214
151
282
20
160
11
235
175
Rp 1 ½
Rp 1 ¼
657
248
279
TM02 9029 1304
C
4
Vol
[m3]
Weight
[kg]
0.045
31.5
JPBasic 5
0
B
A
C
DNA
DNM
Iø
X
A
E
G
TM02 8462 0204
H2
H1
H1
DNE
H
H
V
Voltage [V]
JPBasic 5
Pump
type
JPBasic 5
8
P1
Max.
[kW]
P2
P2
[kW] [hp]
Capacitor
[A]
[µF] [Vc]
31.5 450
1 x 220-240
1.6
1.1
1.5
7.2
3 x 220-240/
380-415
1.6
1.1
1.5
5.2/3.0
-
8
10
16
40
30
200
20
12
18
14
20
Q [US GPM]
160
16
120
6
8
7
5
4
80
3
2
1
100
10
0
0
40
0
0.0
0.0
In
14
60
Electrical data
Pump
type
12
600
300
6
10
Q [IMP GPM]
H
[ft]
200
50
4
8
H
[m]
500
2
6
P
[kPa]
400
0
4
0
0.5 1.0 1.5
0.2
0.4
10
20
2.0 2.5 3.0
0.6
0.8
30
40
50
3.5 4.0 4.5 Q [m³/h]
1.0
1.2
Q [l/s]
60
70
TM02 9026 1304
Z
2
Q [l/min]
-
Packing dimensions
[mm]
Dimensions [mm]
A
B
C
E
F
G
Iø
H
H1
DNA
DNM
L/A
L/B
L/H
558
210
221
350
20
145
11
255
158
Rp 1 ¼
Rp 1
612
248
279
Vol
[m3]
Weight
[kg]
0.045
31
Technical data
JPBasic
JPBasic 7
0
Z
DNA
DNM
TM02 8462 0204
H1
H2
DNE
H
H
H1
Iø
X
A
8
12
16
20
24
28
32
Q [US GPM]
B
A
C
V
4
E
G
P
[kPa]
H
[m]
600
60
Q [IMP GPM]
H
[ft]
200
160
500
50
400
40
300
30
200
20
100
10
0
4
8
12
16
20
24
28
8
120
7
6
5
4
3
80
2
40
1
JPBasic 7
Pump
type
JPBasic 7
P1
P2
P2
In
Capacitor
Max.
[kW]
[kW]
[hp]
[A]
[µF]
[Vc]
1 x 220-240
2.2
1.85
2.5
10
40
450
3 x 220-240/
380-415
2.2
1.85
2.5
6.9/4.0
-
-
Voltage [V]
0
0
0.0
Electrical data
Pump
type
0
0
1
2
3
0.8
0.4
20
40
4
5
1.2
60
80
6
1.6
7
2.0
100
Packing dimensions
[mm]
Dimensions [mm]
A
B
C
E
F
G
Iø
H
H1
DNA
DNM
L/A
L/B
L/H
632
210
221
350
20
145
11
255
158
Rp 1 ¼
Rp 1
657
248
279
Q [m³/h]
Q [l/s]
TM02 9027 1304
0
120 Q [l/min]
Vol
[m3]
Weight
[kg]
0.045
35
9
JPBasic PT
General data
JPBasic PT
Tank
Horizontal type, capacity 19 litres, with butyl
diaphragm, complete with feet on the bottom and
brackets for fixing the pump on top.
Applications
The characteristics of the JPBasic-pumps are that they
are self-priming electric pumps which can operate even
when there is air, gas and small quantities of sand in the
water.
The set is composed of a diaphragm tank with capacity
19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power
cable and plug, kit for coupling the pump and the tank,
all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some
markets.
Constructional features
Pump
Cast iron pump body and motor support.
Technopolymer impeller, diffuser, Venturi tube and sand
guard.
Stainless steel pressure discs.
Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings, to ensure silent running and a long life.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
Manufactured according to standard EN 60335-2-41.
10
6 28
16
4
3
7
Material specification
Automatic water lifting and pressure boosting sets,
particularly suitable for domestic use, small installations for civil, industrial and agricultural use, washing
systems and hobbies.
Motor protection:
Insulation class:
Standard voltage:
1
TM02 8459 3204
TM02 9060 1704General data
8
IP 44
F
1 x 220-240 V, 50 Hz.
Description 
Pos.
Material
1
Pump body
Cast iron (EN-GJL-200)
3
Support
Cast iron (EN-GJL-200)
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
Stainless steel AISI 416
X12 CrS 13
8
Venturi tupe and nozzle
Noryl GFN 2
16
Mechanical seal
Carbon/Ceramic
28
O-Ring gasket
NBR
Components in contact with the liquid.
JPBasic PT
Technical data
Technical data
Operating range:
Up to 3.6 m3/h with head up to 51 metres.
Liquid quality requirements:
Clean, free from solids or abrasive substances, non viscous, non aggressive,
non crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure:
6 bar (600 kPa)
Installation:
Fixed in a horizontal position.
JPBasic PT
D
H1
0
P
[kPa]
H
[m]
50
400
40
2
0
4
2
6
4
8
10
6
45
8
L
TM02 9068 1704
H
B
A
14 Q [US GPM]
10
Q [IMP GPM]
H
[ft]
160
140
JPBasic 2
JPBasic 3
35
300
12
120
JPBasic 4
30
100
25
200
80
20
60
15
100
40
10
20
5
0
0
0
0.0
0.0
0.4
0.8
0.2
1.2
1.6
0.4
2.0
2.4
0.6
2.8
0.8
Q [m³/h]
Q [l/s]
TM02 8940 1704
A1
Electrical data
Voltage [V]
P1
Max.
[kW]
[hp]
[A]
[µF]
[Vc]
JPBasic 2 PT
1 x 220-240
0.72
0.44
3.12
12.5
450
JPBasic 3 PT
1 x 220-240
0.85
0.6
3.8
12.5
450
JPBasic 4 PT
1 x 220-240
1.13
0.75
5.1
16
450
Pump type
Pump type
P1
In
0
Capacitor
Dimensions [mm]
10
Rp 1
576
366
554
0.107
16.1
Rp 1
576
366
554
0.107
16.2
Rp 1
576
366
554
0.107
21.4
Rp 1
Rp 1
332
Rp 1
H
H1
L
JPBasic 2 PT
550
390
270
282
290
232
JPBasic 3 PT
550
390
270
282
290
232
JPBasic 4 PT
550
409
270
282
290
232
Packing dimensions [mm]
Vol
[m3]
332
D
50 Q [l/min]
L/H
332
B
40
L/B
DNM
A1
30
L/A
DNA
A
20
Weight
[kg]
11
JPBasic PS
General data
JPBasic PS
Auto pressure units
Single-phase version:
Self-priming centrifugal pump equipped with pressure
gauge, pressure switch (PS), power supply cable with
plug and three-way brass connector for connecting to a
tank.
Gr7908
JPBasic-PS
Pump type
JPBasic 2 PS
JPBasic 3 PS
JPBasic 4 PS
JPBasic 5 PS
Voltage [V]
P1
Max.
[kW]
Electrical data
P2
P2
In
Max.
[kW]
[hp]
1 x 220-240 0.72 0.44
1 x 220-240 0.85 0.6
1 x 220-240 1.13 0.75
1 x 220-240 1.6 1.1
0.6
0.8
1.0
1.5
12
[A]
[Vc]
3.12
3.8
5.1
7.2
12.5
12.5
16
31.5
450
450
450
450
Dimensions [mm]
Pump type
JPBasic 2 PS
JPBasic 3 PS
JPBasic 4 PS
JPBasic 5 PS
Capacitor
[µF]
A
395
395
414
563
A1
390
390
390
556
B
282
282
282
217
C
108
108
108
160
D
196
196
196
109
E
192
192
192
329
F
14
14
14
15
G
111
111
111
145
Iø
11
H
232
232
232
312
H1
199
199
199
279
H2
200
200
221
H3
144
144
144
159
I
9
9
9
-
DNA
DNM
Rp 1
Rp 1
Rp 1
Rp 1 ¼
Rp 1
Rp 1
Rp 1
Rp 1
Packing dimensions
[mm]
L/A
L/B
L/H
486
366
232
486
366
232
486
366
232
600
236
267
Vol
[m3]
Weight
[kg]
0.041
0.041
0.041
0.038
11.9
12.1
13.9
31.5
JPBasic PC
General data
JPBasic PC
Gr7907
Self-priming centrifugal pump equipped with presscontrol (PC) and power supply cable.
Applications
Automatic water lifting sets, particulary suitable for
domestic use, small installations for civil, industrial and
agricultural use, washing systems and hobbies.
These are characterised by the use of JPBasic PC selfpriming centrifugal pumps which can operate even
when there is air, gas and small quantities of sand in the
water.
They are indispensable for use in artesian wells and
whereever suction difficulties arise.
Operation
The pump is equipped with a Presscontrol (PC) which
controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing
maximum pressure stability inside the hydraulic circuit
in which it is installed.
The automatic devices is the result of a series of studies
conducted to optimise the efficiency of the system while
preserving the structural features and sturdiness of
existent devices.
Automatic sets differ from the traditional systems
equipped with a pressure switch based on pump starting
and stopping as they avoid sudden variations and drops
in pressure. They are basically equipped with a double
control device, as built-in electrical circuit gathers the
data regarding pressure and water flow in the system
and processes them to allow the pump to operate under
optimum performance conditions.
The automatic device is supplied pre-installed on the
pump, requires no type of regulation and considerably
reduces overall dimensions by totally eliminating the
bulky tanks used traditional installations.
13
JPBasic PC
Optimised management of the hydraulic
installation and its components
1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the
system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up.
2. Maintains pump operation when the appliances are
opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is
opened the depression created in the system acts on
the membrane which gradually releases a spring. The
sensors detect the movement, send a signal to the
electronic unit which enables pump start-up.
3. Automatically stops the pump when the users stop
drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the
spring. This new situation is analysed by the sensors
which send the unit a signal to stop the pump. The
stop is timed in order to prevent the pump from being subjected to repeated starts caused by users
opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is
guaranteed by timing the stops.
4. Instant pump start when one of the appliances is
opened even with a minimum amount of water
drawn.
5. In the event of leaks in the system (drips or small
trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds.
6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect.
7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention;
in this case, after eliminating the cause, press the
"RESET" button positioned on the terminal board
cover for a few seconds until the "ALARM" LED
switches off.
8. In the event of a power cut, automatic reset as soon
as the power is restored.
9. The system is self-protected against overheating.
When there is an excess in temperature inside the
motor windings, this operation is carried out automatically. It is also restored automatically once the
temperature has dropped below the level which
guarantees operation without damage to the system.
14
General data
Constructional features of the pump
JPBasic 3 PC, JPBasic 4 PC:
Cast iron pump body and motor support treated against
corrosion also on the inner surface. Technopolymer
impeller, diffuser and Venturi tube. Stainless steel pressure discs and rotor shaft. Carbon/ceramic mechanical
seal.
Constructional features of the motor
Induction motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball
bearings. Built-in thermal and current oyerload protection and a capacitor permanently in circuit.
Manufactured according to standard EN 60335-2-41.
Motor protection:
Insulation class:
IP 44
F.
All the pumps are supplied with 0.75 metres of power
cable type H05 RN-F with plug.
Constructional features of the automatic control
The automatic device which regulates the pump operation is basically formed of the following components:
FLOW SWITCH SET: this comprises a 4-way metal union
with two housings for the delivery and pressure sensors.
Both their seat and the sensor capsule are structured so
that no pre-calibration is required.
SPRING EXPANSION TANK: manufactured in pressed and
flanged stainless steel, this has been designed to ensure
maximum reliability and sturdiness with minimum
overall dimensions. Inside it houses a spring which operates as a pressure switch.
ELECTRONIC CARD: this is composed of a printed circuit
which receives signals from the sensors and manages
the automatic device as indicated in the paragraph
regarding operation. The commands plate with the two
LEDs, green = ON, red = Alarm and the Reset button for
resetting the pump is positioned on the terminal board
cover.
CHECK DEVICE: all automatic sets are equipped with a
check valve which has been selected to ensure
maximum long lasting reliability. In order to prevent
operational faults in the system it is essential that the
position of the valve is not changed during assembly.
The automatic control is supplied pre-assembled with all
the accessories.
JPBasic PC
Technical data
Technical data
Operating range:
From 0.3 to 3.6 m3/h with head up to 51 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure:
6 bar (600 kPa)
Installation:
Fixed in a horizontal position.
JPBasic PC
C
0
P
[kPa]
H
[m]
50
400
40
2
0
4
2
6
4
8
6
H
DNA
45
8
14 Q [US GPM]
10
Q [IMP GPM]
H
[ft]
160
140
JPBasic 3
120
JPBasic 4
30
100
TM02 9067 1704
H3
25
Iø
F
G
E
A
B
200
80
20
60
15
100
40
10
20
5
0
0
0
0.0
0.0
Electrical data
Pump type
12
JPBasic 2
35
300
10
Voltage [V]
0
P1
P2
P2
In
Capacitor
Max.
[kW]
[kW]
[hp]
[A]
[µF]
[Vc]
JPBasic 2 PC
1 x 220-240
0.72
0.44
0.6
3.12
12.5
450
JPBasic 3 PC
1 x 220-240
0.85
0.60
0.8
3.4
12.5
450
JPBasic 4 PC
1 x 220-240
1.13
0.75
1.0
4.7
16
450
Dimensions [mm]
Pump type
0.4
0.8
0.2
10
1.2
1.6
0.4
20
2.0
2.4
0.6
30
2.8
0.8
40
Q [m³/h]
Q [l/s]
TM02 8940 1704
DNM
50 Q [l/min]
DNA
DNM
Packing dimensions
[mm]
Vol
[m3]
Weight
[kg]
A
B
C
E
F
G
Iø
H
H3
L/A
L/B
L/H
JPBasic 2 PC
395
212
108
192
14
111
9
375.5
144
Rp 1
Rp 1
524
248
309
0.04
14
JPBasic 3 PC
395
212
108
192
14
111
9
375.5
144
Rp 1
Rp 1
524
248
309
0.04
16
JPBasic 4 PC
414
212
108
197
14
111
9
375.5
144
Rp 1
Rp 1
524
248
309
0.04
16
15
JDBasic
General data
JDBasic 5, JDBasic 7
TM00 9974 1097
Gr7899General data
JDBasic 2, JDBasic 4
Motor
Applications
Self-priming centrifugal pump for suction up to 27
metres, reached by means of an ejector to be inserted in
wells with a diameter of 4" or over. For use in supplying
water to farmhouses and in small-scale agriculture.
Asynchronous motor, closed and cooled with external
ventilation.
Rotor mounted on greased sealed-for-life ball bearings,
selected to ensure silent running and a long life.
Built-in thermal and current overload protection and a
capacitor permanently in circuit in the single-phase
version.
Constructional features
Pump
Cast iron pump body and motor support treated against
corrosion also on the inner surface. Technopolymer
impeller, diffuser and Venturi tupe and brass nozzle.
Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension.
Ejector: Cast iron body with anti-corrosive treatment
also on the inner surface.
Technopolymer Venturi tube and brass nozzle.
The ejector is available in 3 models (E20 - E25
- E30) to be chosen according to performance
requirements.
(see tables on pages 17 and 18).
For the protection of the three-phase motor it is advisable to use a suitable overload protection complying
with the regulations in force.
Manufactured according to standard EN 60335-2-41.
Motor protection:
Terminal box protection:
Insulation class:
Standard voltage:
IP 44
IP 55
F
1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
Material specification
Description
Material
1
Pump body
Cast iron EN-GJL-200
2
Ejector body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
Shaft with rotor
(JDBasic 2-4)
Stainless steel AISI 416
X 12 Cr S 13
7
(JDBasic 5-7)
AISI 303 X10 Cr NiS 18 9
16
8
Venturi
Noryl GFN 2
9
Nozzle
Brass
16
Mechanical seal
Carbon/Ceramic
28
O-ring gasket
NBR
8
1 6 28
3
2
9
16 4
7
TM02 8456 0204
Pos.
JDBasic
Technical data
Technical data
Operating range:
Up to 4.3 m3/h
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use
Maximum ambient temperature: + 40°C
JDBasic 2, JDBasic 4: 6 bar (600 kPa)
JDBasic 5, JDBasic 7: 8 bar (800 kPa)
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
TM00 9976 1097
Maximum operating pressure:
JDBasic 2, JDBasic 4
Hydraulic data (n ≈ 2850 min -1)
Delivery pressure in bar
Pump Ejector Suction
type
type
depth
Z
1.5
2.0
E30
G
B
TM02 8455 0204
X
JDBasic 4
E25
E30
Dimensions [mm]
DNM
DNE
JDBasic 2 365 180 90 202 140 9,5 225 47 92
G1¼
G1
G1
97
295
JDBasic 4 385 180 90 202 140 9,5 225 47 92
G1¼
G1
G1
97
295
B
C
E
JDBasic 2
G
I
H
H1 H2
P1
P2
P2
Voltage [V]
Max.
[kW]
[kW]
[hp]
1 x 220-240
0.69
0.44
0.6
3 x 220-240/
380-415
4.0
9
1813
1080
446
33
/
/
1426
720
225
/
/
/
15
900
326
/
/
/
/
9
1753
1286
812
524
261
46
12
1345
965
608
356
162
0
15
1166
761
452
228
45
/
9
2386
1756
1097
515
126
/
12
1930
1190
536
87
/
/
15
1459
773
252
/
/
/
12
/
1240
872
566
329
156
15
/
1028
701
449
255
96
18
/
785
527
302
150
15
21
/
635
374
180
39
/
A
H
H1
[mm] [mm] [mm]
Packing dimensions
0.66
0.44
0.6
Vol
L/A
L/B
L/H [m3]
[mm] [mm] [mm]
x
y
z
243
G1
G1
G1¼
452
218
257
0.025 13.9
243
G1
G1
G1¼
492
224
277
0.025 16.6
Electrical data
Pump
type
3.5
12
Ejector
DNA
A
3.0
Weight
[kg]
E25
JDBasic 2
H1
H2
H
H
V
Pump
type
2.5
Capacity table in [l/h]
A
Electrical data
In
Capacitor
[A]
[µF]
[Vc]
3.2
14
450
2.6/1.5
-
-
Pump
type
JDBasic 4
P1
P2
P2
Voltage [V]
Max.
[kW]
[kW]
[hp]
1 x 220-240
0.79
0.75
1
3 x 220-240/
380-415
0.64
0.75
1
In
Capacitor
[A]
[µF]
[Vc]
3.8
16
450
2.6/1.5
-
-
17
JDBasic
Technical data
JDBasic 5, JDBasic 7
Hydraulic data (n ≈ 2850 min -1)
Pump Ejector Suction
3.0
type type depth
DNM
V
JDBasic 5
E 20
IØ
E 25
G
E
E 30
Z
JDBasic 7
TM02 8457 0204
H
H1
Dimensions [mm]
Pump type
A
B
C
E
G
I
H
3412 2769 2090 1363 586
/
/
/
/
/
/
3065 2400 1719 952 143
/
/
/
/
/
/
15
2643 2000 1257 495
/
/
/
/
/
/
/
18
2289 1593 826
/
/
/
/
/
/
/
15
2745 2244 1761 1257 814 435 77
/
/
/
/
18
2465 1969 1477 997 584 218 /
/
/
/
/
21
2206 1712 1224 779 388 45
/
/
/
/
21
1797 1615 1368 1106 861 658 472 312 163 25 /
DNA
DNM DNE
A
H
H1
[mm] [mm] [mm]
/
/
/
/
/
9
/
3431 2751 2033 1236 448 /
/
/
/
/
12
/
3043 2324 1554 763
0
/
/
/
/
/
15
/
2665 1936 1145 344
/
/
/
/
/
/
18
/
2244 1478 675
/
/
/
/
/
/
15
/
2840 2324 1806 1296 849 463 138 /
/
/
18
/
2535 2038 1523 1049 640286 /
/
/
/
21
/
2267 1757 1257 817 424 91 /
/
/
/
24
/
1970 1458 989 583 226 /
/
/
/
21
/
1812 1671 1419 1163 919 716 531 377 226 91
24
/
1668 1549 1278 1023 791 619 445 297 156 13
27
/
1541 1395 1145 906 700 521 351 206 62 /
Ejector
H1 H2
0
1652 1484 1217 962 740 547 378 220 67
E 25
E 30
9
12
1520 1333 1069 841 636 448 287 139 /
E 20
E
4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Capaticy table [l/h]
27
C
X
4.0
24
A
V
Delivery pressure [bar]
3.5
/
/
Packing dimensions [mm]
x
y
z
L/A
L/B
L/H
Weight
[kg]
B
A
C
Vol
[m3]
JDBasic 5
388 210 50 197 145 11 255 53 108
G1¼
G1
G1
97
295
243
G1 G1 G1¼
427
246
307
0.032
31
JDBasic 7
462 210 50 197 145 11 255 53 108
G1¼
G1
G1
97
295
243
G1 G1 G1¼
522
246
307
0.039
35
Electrical data
Pump
type
P1
P2
Electrical data
P2
Voltage [V]
Max.
[kW]
[kW]
[hp]
JDBasic 5
1 x 220-240
1.56
1.1
1.5
JDBasic 7
1 x 220-240
2.1
1.85
2.5
In
Capacitor
[A]
[µF]
[Vc]
7
31.5
450
8.3
40
450
Pump
type
P1
Max.
[kW]
P2
P2
[kW]
[hp]
[A]
JDBasic 5 3 x 220-240/380-415
1.45
1.1
1.5
4.7/2.7
JDBasic 7 3 x 220-240/380-415
1.78
1.85
2.5
5.6/3.2
Voltage [V]
In
Instructions for conversion
TM00 9980 1097 & TM00 9981 1097
Conversion from JDBasic 5, JDBasic 7 to JPBasic 5,
JPBasic 7
18
Screw the nozzle (9) into the seat in the ejector body (2)
and the Venturi tube (8).
Position the O-rings (27) and (29) in their respective
seats and fix the ejector body (2) onto the pump body (1)
with the two screws (53).
Conversion from JPBasic 5, JPBasic 7 to JDBasic 5,
JDBasic 7
Slacken and remove the two joining screws (53)
between the ejector body (2) and the pump body (1).
Collect the O-rings (27) and (29).
CHBasic
CHBasic
Performance range
p
[kPa]
H
[m]
CHBasic
600
50 Hz
60
3
55
500
50
4
45
400
2
40
35
300
30
25
200
20
15
100
10
5
0
0.0
0.0
0.5
1.0
0.2
1.5
0.4
2.0
0.6
2.5
3.0
0.8
3.5
1.0
4.0
4.5
1.2
5.0
1.4
5.5
6.0
1.6
6.5
1.8
7.0
7.5
2.0
Q [m³/h]
Q [l/s]
TM02 8933 1804
0
19
CHBasic
General data
CHBasic 2, CHBasic 3, CHBasic 4
6
3
Gr7896
4
Applications
Multistage horizontal centrifugal pump, featuring
extremely silent running suitable for domestic use for
water supply and pressurisation, irrigation of gardens
and vegetable gardens, and moving water in general.
Constructional features
Pump
Pump body in cast iron. Motor support in die-cast
aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit in the single-phase
version.
The user is responsible for protection in the three-phase
version.
Motor protection:
IP 44
Terminal box protection: IP 55
Insulation class:
F
Standard voltage:
1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz.
20
16 28
TM02 9065 3204
1
7
Material specification
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
Stainless steel AISI 303 X10 CrNiS 18 9
16
Mechanical seal
Carbon/Ceramic
28
O-ring gasket
NBR
CHBasic
Technical data
Technical data
Operating range:
From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive, chemically neutral and
close to the characteristics of water.
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth:
8 metres (800 kPa)
Maximum operating pressure:
CHBasic 2, CHBasic 3, CHBasic 4:
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
6 bar (600 kPa)
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
21
CHBasic
Technical data
CHBasic 2
0
2
4
6
8
10
12
8
10
14
16
18
Q [US GPM]
A
C
0
2
4
6
12
14
16 Q [IMP GPM]
H
[ft]
160
P
[kPa]
H
[m]
50
400
40
300
30
100
25
80
H2
H
H1
DNA
45
TM02 9062 1704
G
B
200
20
100
1x220-240
CHBasic 2
3x220-240/380-415
P2
P2
0
Capacitor
[hp]
[A]
[µF] [Vc]
0.72 0.45 0.6
3.2
0.7
0
0.0
0.0
In
[kW]
20
5
0.45 0.6 2.2/1.3
0.5
1.0
0.2
0
10
450
-
-
10
1.5
0.4
20
2.0
2.5
3.0
0.6
0.8
30
40
3.5
4.0 Q [m³/h]
1.0
1.2 Q [l/s]
50
60
70Q [l/min]
Packing dimensions
[mm]
Dimensions [mm]
Pump
type
CHBasic 2
P1
Max.
[kW]
40
10
Electrical data
Voltage [V]
60
15
0
Pump type
120
35
IØ
F
E
140
A
B
C
E
F
G
Iø
H
H1
H2
DNA
DNM
L/A
L/B
L/H
406
175
122
207
13.5
111
9
200
179
143.5
Rp 1
Rp 1
480
212
265
TM02 9009 1304
DNM
Vol
[m3]
Weight
[kg]
0.027
12.5
CHBasic 3
0
2
4
6
8
10
12
8
10
14 16 18 20 22 24
Q [US GPM]
A
DNM
H2
G
B
500
50
400
40
300
TM02 9062 1704
IØ
F
E
H 0
[m]
55
CHBasic 3
Pump
type
CHBasic 3
22
P2
P2
6
12
14
16
18
20
Q [IMP GPM]
H
[ft]
160
140
120
30
100
25
80
200
20
100
10
60
15
40
20
5
0
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m³/h]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Q [l/s]
Electrical data
P1
Max.
[kW]
[kW]
[hp]
1x220-240
1.2
0.75
1
5.3
20
450
3x220-240/380-415
1.2
0.75
1
3.8/2.2
-
-
Voltage [V]
4
35
0
Pump
type
2
45
H
H1
DNA
P
[kPa]
In
Capacitor
[A]
[µF] [Vc]
0
10
20
30
40
50
60
70
80
Packing dimensions
[mm]
Dimensions [mm]
A
B
C
E
F
G
Iø
H
H1
H2
DNA
DNM
L/A
L/B
L/H
425
175
122
207
13.5
111
9
213
179
143.5
Rp 1
Rp 1
480
212
265
90 Q [l/min]
TM02 9010 1304
C
Vol
[m3]
Weight
[kg]
0.027
15.4
CHBasic
Technical data
CHBasic 4
0
4
8
12
16
20
24
28
32
Q [US GPM]
A
C
0
4
8
12
16
20
24
28
Q [IMP GPM]
H
[ft]
160
P
[kPa]
H
[m]
50
400
40
300
30
100
25
80
H2
H
H1
DNA
45
TM02 9062 1704
G
B
200
20
100
CHBasic 4
P1
Max.
[kW]
P2
20
5
0
0
0
0.0
P2
In
Capacitor
[kW] [hp]
[A]
[µF] [Vc]
5.3
1x220-240
1.2
0.8
1.1
3x220-240/380-415
1.2
0.8
1.1 3.8/2.2
0
20
450
-
-
1
2
3
0.8
0.4
20
40
4
5
1.2
60
80
6
1.6
7
2.0
100
Packing dimensions
[mm]
Dimensions [mm]
Pump type
CHBasic 4
40
10
Electrical data
Voltage [V]
60
15
0
Pump type
120
35
IØ
F
E
140
A
A1
B
C
E
F
G
H
H3
I
DNA
DNM
L/A
L/B
L/H
425
175
122
207
13.5
111
9
213
179
143.5
Rp 1
Rp 1
480
212
265
Q [m³/h]
Q [l/s]
120 Q [l/min]
TM02 9011 1304
DNM
Vol
[m3]
Weight
[kg]
0.027
15.4
23
CHBasic PT
General data
CHBasic PT
6
3
Applications
The set is composed of a diaphragm tank with capacity
19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power
cable and plug, kit for coupling the pump and the tank,
all assembled and ready for installation.
Note: Vertical 8 litres or 18 litres tanks are used in some
markets.
Constructional features
Pump
Pump body in cast iron. Motor support in die-cast
aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
IP 44
IP 55
F
1 x 220-240 V, 50 Hz.
Tank
Horizontal type, capacity 19 litres, with butyl
diaphragm, complete with feet on the bottom and
brackets for fixing the pump on top
24
16 28
7
Material specification
Multistage horizontal centrifugal pump, featuring
extremely silent running suitable for domestic use for
water supply and pressurisation, irrigation of gardens
and vegetable gardens, and moving water in general.
Motor protection:
Terminal box protection:
Insulation class:
Standard voltage:
4
TM02 9065 3204
TM02 9061 1704
1
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
AISI 303 stainless steel X 10 Cr NiS 18 9
16
Mechanical seal
Carbon/Ceramic
28
O-ring gasket
NBR
CHBasic PT
Technical data
Technical data
Operating range:
From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth:
8 metres (800 kPa)
Maximum operating pressure:
CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa)
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
CHBasic 2 PT
A1
D
0
500
H 0
[m]
55
8
12
4
8
16
20
12
24
16
28
20
32
24
Q [US GPM]
28
Q [IMP GPM]
H
[ft]
50
160
45
A
300
TM02 9066 1704
H
400
B
CHBasic 2 PT
CHBasic 3 PT
1 x 220-240
CHBasic 4 PT
120
30
100
25
80
20
100
10
60
15
40
20
5
CHBasic 2
P1
P2
P2
In
Max.
[kW]
Capacitor
[kW]
[hp]
[A]
[µF]
[Vc]
0.72
0.45
0.60
3.2
12.5
450
1.2
0.75
1.0
5.3
12.5
450
1.2
0.80
1.1
5.3
16
450
CHBasic 4
0
0
1
2
3
0.8
0.4
20
40
4
5
1.2
60
6
1.6
80
100
Packing dimensions
[mm]
Dimensions [mm]
Pump type
CHBasic 3
0
0
0.0
Electrical data
Voltage [V]
35
200
0
Pump type
140
40
7
2.0
Q [m³/h]
Q [l/s]
TM02 8939 1704
H1
P
[kPa]
4
120 Q [l/min]
Vol
[m3]
Weight
[kg]
A
A1
B
D
H
H1
L
DNA
DNM
L/A
L/B
L/H
CHBasic 2 PT
550
405
270
281
290
200
330
Rp 1
Rp 1
576
366
554
0.107
17.7
CHBasic 3 PT
550
425
270
281
290
200
330
Rp 1
Rp 1
576
366
554
0.107
20.6
CHBasic 4 PT
550
425
270
281
290
200
330
Rp 1
Rp 1
576
366
554
0.107
20.6
25
CHBasic PS
General data
CHBasic PS
6
3
Gr7918
4
Applications
Constructional features
Pump
Pump body in cast iron. Motor support in die-cast
aluminium, seal holder in stainless steel.
Mechanical seal in carbon/ceramic. Shaft in stainless
steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
26
7
Material specification
Multistage horizontal centrifugal pump, featuring
extremely silent running suitable for domestic use for
water supply and pressurisation, irrigation of gardens
and vegetable gardens, and moving water in general.
Motor protection:
Terminal box protection:
Insulation class:
Standard voltage:
16 28
TM02 9065 3204
1
IP 44
IP 55
F
1 x 220-240 V, 50 Hz.
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
AISI 303 stainless steel X 10 Cr NiS 18 9
16
Mechanical seal
Carbon/Ceramic
28
O-ring gasket
NBR
CHBasic PS
Technical data
Technical data
Operating range:
From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth:
8 metres (800 kPa)
Maximum operating pressure:
CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa)
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
CHBasic PS
0
4
8
12
16
20
24
28
32
Q [US GPM]
A
D
DNM
DNM
H 0
[m]
55
P
[kPa]
500
4
8
12
16
20
24
28
Q [IMP GPM]
H
[ft]
50
160
E
H2
Iø
F
TM02 9064 1704
H1
H3
DNA
H
45
G
B
40
35
120
300
30
100
25
80
200
20
100
CHBasic 2 PS
CHBasic 3 PS
1 x 220-240
CHBasic 4 PS
40
10
20
5
CHBasic 2
P2
P2
In
Max.
[kW]
[kW]
[hp]
[A]
1
2
3
0.8
0.4
4
5
1.2
6
1.6
7
2.0
Q [m³/h]
Q [l/s]
Capacitor
[µF]
[Vc]
1.75
0.45
0.60
3.2
10
450
1.20
0.75
1.00
5.3
20
450
1.20
0.80
1.10
5.3
20
450
0
20
40
60
80
100
Packing dimensions
[mm]
Dimensions [mm]
Pump type
CHBasic 4
0
0
0.0
P1
CHBasic 3
0
Electrical data
Voltage [V]
60
15
0
Pump type
140
400
TM02 8939 1704
C
120 Q [l/min]
Vol
[m3]
Weight
[kg]
A
B
C
D
E
F
G
H
H1
H2
H3
I
DNA
DNM
L/A
L/B
L/H
CHBasic 2 PS
405
281
122
196
205
14
111
238
205
200
144
9
Rp 1
Rp 1
449
309
244
0.03
14
CHBasic 3 PS
425
281
122
196
205
14
111
238
205
200
144
9
Rp 1
Rp 1
449
309
244
0.031
17
CHBasic 4 PS
425
281
122
196
205
14
111
238
205
200
144
9
Rp 1
Rp 1
449
309
244
0.03
17
27
CHBasic PC
General data
CHBasic PC
the membrane which gradually releases a spring. The
sensors detect the movement, send a signal to the
electronic unit which enables pump start-up.
Gr7916
3. Automatically stops the pump when the users stop
drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the
spring. This new situation is analysed by the sensors
which send the unit a signal to stop the pump. The
stop is timed in order to prevent the pump from being subjected to repeated starts caused by users
opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is
guaranteed by timing the stops.
Applications
Multistage horizontal centrifugal pump, featuring
extremely silent running suitable for domestic use for
water supply and pressurisation, irrigation of gardens
and vegetable gardens, and moving water in general.
Operation
The pump is equipped with a Presscontrol (PC) which
controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing
maximum pressure stability inside the hydraulic circuit
in which it is installed.
The automatic devices is the result of a series of studies
conducted to optimise the efficiency of the system while
preserving the structural features and sturdiness of
existent devices.
Automatic sets differ from the traditional systems
equipped with a pressure switch based on pump starting
and stopping as they avoid sudden variations and drops
in pressure. They are basically equipped with a double
control device, as built-in electrical circuit gathers the
data regarding pressure and water flow in the system
and processes them to allow the pump to operate under
optimum performance conditions.
The automatic device is supplied pre-installed on the
pump, requires no type of regulation and considerably
reduces overall dimensions by totally eliminating the
bulky tanks used traditional installations.
Optimised management of the hydraulic
installation and its components
1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the
system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up.
2. Maintains pump operation when the appliances are
opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is
opened the depression created in the system acts on
28
4. Instant pump start when one of the appliances is
opened even with a minimum amount of water
drawn.
5. In the event of leaks in the system (drips or small
trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds.
6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect.
7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention;
in this case, after eliminating the cause, press the
"RESET" button positioned on the terminal board
cover for a few seconds until the "ALARM" LED
switches off.
8. In the event of a power cut, automatic reset as soon
as the power is restored.
9. The system is self-protected against overheating.
When there is an excess in temperature inside the
motor windings, this operation is carried out automatically. It is also restored automatically once the
temperature has dropped below the level which
guarantees operation without damage to the system.
Constructional features
Pump
Pump body in cast iron. Motor support in die-cast
aluminium, seal holder in AISI 304 steel.
Mechanical seal in carbon/ceramic. Rotor shaft in AISI
304 steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel.
Motor
Continuous service asynchronous motor (2 poles) cooled
by external fan.
Built-in thermal and current overload protection and a
capacitor permanently in circuit.
Motor protection:
Terminal box protection:
Insulation class:
Standard voltage:
IP 44
IP 55
F
1 x 220-240 V, 50 Hz.
CHBasic PC
6
Technical data
3
4
16 28
TM02 9065 3204
1
7
Material specification
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
6
Diffuser
Noryl GFN 2
7
Shaft
AISI 303 stainless steel X 10 Cr NiS 18 9
16
Mechanical seal
Carbon/Ceramic
28
O-ring gasket
NBR
29
CHBasic PC
Technical data
Technical data
Operating range:
From 0.6 to 10.5 m3/h with head up to 63 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non aggressive
Liquid temperature range:
From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41)
From 0°C to +40°C for other uses.
Maximum ambient temperature: +40°C
Maximum suction depth:
8 metres (800 kPa)
Maximum operating pressure:
CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa)
Installation:
Fixed in a horizontal position
Special executions on request:
Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
CHBasic PC
C
DMN
0
E
B
A
300
TM02 9063 1704
Iø
G
F
8
20
12
24
16
28
20
32
24
Q [US GPM]
28
Q [IMP GPM]
H
[ft]
160
Voltage [V]
CHBasic 2 PC
1 x 220-240
CHBasic 4 PC
140
40
35
120
30
100
25
80
20
100
10
60
15
40
20
5
CHBasic 2
P1
P2
P2
In
Max.
[kW]
[kW]
[hp]
[A]
0.72
0.45
0.6
1.2
0.75
1.0
1.2
0.80
1.1
Capacitor
[Vc]
3.2
10
450
5.3
20
450
5.3
20
450
1
2
3
0.8
0.4
20
40
4
5
1.2
60
6
1.6
80
100
Packing dimensions
[mm]
Dimensions [mm]
Pump type
CHBasic 4
0
0
[µF]
CHBasic 3
0
0
0.0
Electrical data
30
4
16
50
200
0
CHBasic 3 PC
12
45
400
Pump type
H 0
[m]
55
8
7
2.0
Q [m³/h]
Q [l/s]
TM02 8939 1704
500
DNA
H
P
[kPa]
4
120 Q [l/min]
Vol
[m3]
Weight
[kg]
A
B
C
E
F
G
H
Iø
DNA
DNM
L/A
L/B
L/H
CHBasic 2 PC
406
212
122
207
13.5
111
376
9
Rp 1
Rp 1
524
248
309
0.04
14
CHBasic 3 PC
425
212
122
207
13.5
111
376
9
Rp 1
Rp 1
524
248
309
0.04
16
CHBasic 4 PC
425
212
122
207
13.5
111
376
9
Rp 1
Rp 1
524
248
309
0.04
16
NSBasic
NSBasic
Single impeller
Performance range
p
[kPa]
700
H
[m]
NSBasic
70
50 Hz
65
600
5-60
60
55
500
5-50
50
45
400
6-40
3-40
40
6-30
35
5-33
300
30
25
4-23
200
20
13-18
15
100
10
5
0
0
0.0
1
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
2.5
10
11
3.0
12
13
3.5
14
4.0
15
16
4.5
17 Q [m³/h]
Q [l/s]
TM02 8934 1804
0
31
NSBasic
General data
NSBasic single impeller pumps
Gr7897
Applications
Constructional features
Pump
Motor
Induction motor, closed and cooled with external fan.
Rotor mounted on oversized greased sealed-for-life ball
bearing to ensure silent running and long life. Built-in
thermal and current overload protection and a capacitor
permanently in circuit in the single-phase version. The
user is responsible for the protection in the three-phase
version.
Manufactured according to standard EN 60335-2-41.
32
16
7
Description
IP 44
IP 55 for the single-phase
version
F
1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.
Material
1
Pump body
Cast iron EN-GJL-200
3
Support
Cast iron EN-GJL-200
4
Impeller
Noryl GFN 2
7
Shaft
Pump types
X 12 CrNi 1810
NSBasic 4-23 - NSBasic 13-18
X 10 CrNi 1809
NSBasic 5-33
16 Mechanical seal Carbon/Ceramic
28 O-Ring Gasket
Cast iron pump body and motor support treated against
corrosion also on the inner surface.
Technopolymer and cast iron impeller.
Carbon/ceramic mechanical seal mounted on stainless
steel rotor shaft extension.
Insulation class:
Standard voltage:
3
Material specification
Single impeller centrifugal pump designed for lifting
water in domestic, civil, industrial and agricultural
installations and for decanting, mixing and irrigating
uses.
Motor protection:
Terminal box protection:
28
TM02 9070 1704
4
1
NBR
NSBasic
Technical data
Technical data
Operating range:
From 1.8 to 16.8 m3/h with head up to 34 metres
Liquid quality requirements:
Clean, free from solids or abrasive substances, non viscous, non aggressive,
noncrystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range:
NSBasic 4-23, NSBasic 5-33, NSBasic 13-18:
Maximum ambient temperature:
+40°C
Maximum operating pressure:
NSBasic 4-23, NSBasic 5-33, NSBasic 13-18:
Installation:
Fixed in a horizontal or vertical position, as long
as the motor is above the pump
Special versions on request:
Other voltages and/or frequencies.
from -10°C to + 50°C
6 bar (600 kPa)
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
NSBasic 4-23
0
4
0
4
12
16
8
12
20
16
24
Q [US GPM]
20
Q [IMP GPM]
H
[ft]
H
[m]
20
TM02 9089 1804Single impeller
160
80
60
15
40
10
20
5
0
P2
[hp]
0.4
0.2
0.0
0
P2
[kW]
0.4
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h]
P2
0.2
20
Eta
0.0
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Q [l/s]
Electrical data
Pump
type
NSBasic 4-23
Voltage [V]
1x220-240
P1
P2
P2
Max.
[kW] [kW] [hp]
In
Capacitor
[A]
[µF] [Vc]
0.65
3.0
0.37
NSBasic 4-23 3x220-240/380-415 0.64 0.37
Pump
type
NSBasic 4-23
0.5
0.5 2.3/1.3
10
450
-
-
0
Dimensions [mm]
A
B
C
D
E
F
G
I
H
H1
H2
275
160
50
100
50
15
110
9
205
85
120
Eta
[%]
40
DNA
DNM
Rp 1
Rp 1
10
20
30
40
50
60
70
80
Packing dimensions [mm]
90
Q [l/min]
TM02 9012 1304
P
[kPa]
8
L/A
L/B
L/H
Vol
[m3]
Weight
[kg]
362
222
262
0.021
10.3
33
NSBasic
Technical data
NSBasic 5-33
0
4
0
P
[kPa]
320
8
4
12
16
8
20
12
24
16
28
20
32
24
36
28
Q [US GPM]
H
[m]
32 Q [IMP GPM]
H
[ft]
30
100
240
TM02 9089 1804
160
80
20
80
10
0
0
P2
[hp]
0.8
0.4
0.0
60
40
20
0
P2
[kW]
0.8
0
1
2
3
4
5
6
7
8
Q [m³/h]
P2
0.4
Eta
[%]
40
20
Eta
0.0
0
0.0
0
1
2
3
0.8
0.4
4
5
1.2
6
1.6
7
2.0
8
Q [m³/h]
2.4 Q [l/s]
Pump
type
NSBasic 5-33
P1
P2
P2
Max.
[kW] [kW] [hp]
Voltage
[V]
1x220-240
NSBasic 5-33 3x220-240/380-415
Pump
type
NSBasic 5-33
In
Capacitor
[A]
[µF] [Vc]
1.3
0.75
1
6.0
20
450
1.2
0.75
1
4.3/2.5
-
-
0
Dimensions [mm]
DNA
A
B
C
D
E
F
G
I
H
H1
H2
300
185
50
108
58
15
140
9
235
100
135
20
40
80
100
120
Packing dimensions
[mm]
DNM
Rp 1
60
Rp 1
L/A
L/B
L/H
392
232
262
TM02 9013 1304
Electrical data
Q [l/min]
Vol
[m3]
Weight
[kg]
0.024
14.7
NSBasic 13-18
0
0
5
10 15 20 25 30 35 40 45 50 55 60
H
[m]
Q [US GPM]
Q [IMP GPM]
H
[ft]
20
160
80
60
15
40
10
20
5
TM02 9089 1804
0
P2
[hp]
0.8
0.4
0.0
0
P2
[kW]
0.8
0
0
2
4
6
8
10
12
14
16
Q [m³/h]
P2
0.4
Eta
[%]
40
20
Eta
0.0
0
0.0
2
0.5
0
4
1.0
6
1.5
8
2.0
10
12
14
2.5 3.0 3.5 4.0
16
4.5
Q [m³/h]
Q [l/s]
TM02 9014 1304
P
[kPa]
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Electrical data
Pump
type
NSBasic 13-18
Voltage
[V]
P1
P2
P2
Max.
[kW] [kW] [hp]
1x220-240
NSBasic 13-18 3x220-240/380-415
Pump
type
NSBasic 13-18
34
In
Capacitor
[A]
[µF] [Vc]
1.1
0.75
1
4.6
20
450
1.1
0.75
1
3.6/2.1
-
-
0
Dimensions [mm]
A
B
C
D
E
F
G
I
H
H1
H2
312
169
45
114
69
15
110
9
210
210
125
40
DNA
DNM
Rp 1½
Rp 1½
80
120
160
200
240
Packing dimensions
[mm]
L/A
L/B
L/H
392
232
262
Q [l/min]
Vol
[m 3]
Weight
[kg]
0.024
14
NSBasic
General data
NSBasic twin impeller pumps
1
4 28
3
16
TM02 9069 1704
Gr7928
34
7
Material specification
Applications
Muliti-stage centrifugal pump with opposed twin
impellers.
Designed for use in pressurisation units for water
supply systems and for supplying pressurised tanks.
Suitable also for sprinkling, irrigation and other water
supply application.
Constructional features
Pump
Cast iron pump body and motor support treated against
corrosion also on the inner surface.
Technopolymer and cast iron impeller. Carbon/ceramic
mechanical seal mounted on stainless steel rotor shaft
extension.
Description
Material
1
Pump body
Cast iron
EN-GJL-200
3
Support
Cast iron
EN-GJL-200
4
Impeller
7
Shaft
Pump types
Noryl GFN 2
NSBasic 3-40 - NSBasic 5-50 NSBasic 6-30 - NSBasic 6-40
Ultem 2300
NSBasic 5-60
Stainless steel
ANSI X12
CrNi 1810
16 Mechanical seal
Carbon/Ceramic
28 O-ring gasket
Impregnated
Cellulose
34 Intermediate Disc
Cast iron
EN-GJL-200
Motor
Induction motor, closed and cooled with external fan.
Rotor mounted on oversized greased sealed-for-life ball
bearing to ensure silent running and long life. Built-in
thermal and current overload protection and a capacitor
permanently in circuit in the single-phase version. The
user is responsible for the protection in the three-phase
version.
Manufactured according to standard EN 60335-2-41.
Motor protection:
Terminal box protection:
Insulation class:
Standard voltage:
IP 44
IP 55 for the single-phase
version up to
and including 0.75 kW
F
1x220-240 V, 50 Hz
3x220-240/380-415 V, 50 Hz.
35
NSBasic
Technical data
Technical data
Operating range:
From 1.5 to 10.8 m3/h with head up to 60 metres.
Liquid quality requirements:
clean, free from solids or abrasive substances, non viscous, non aggressive, non
crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range:
NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from –10°C to + 50°C
NSBasic 5-60:
from –15°C to + 110°C
Maximum ambient temperature:
+40°C
Maximum operating pressure:
NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa)
NSBasic 5-50, NSBasic 5-60:
8 bar ( 800 kPa)
Installation:
Fixed in a horizontal or vertical position, as long as the motor is above the
pump.
Special versions on request:
Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
NSBasic 3-40
0
4
TM02 9088 1804Twin impeller
0
P
[kPa]
400
H
[m]
300
30
200
20
100
10
0
0
P2
[hp]
0.8
0.4
0.0
8
4
12
16
8
12
20
16
24
Q [US GPM]
20
Q [IMP GPM]
H
[ft]
40
P2
[kW]
0.8
120
80
40
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h]
P2
0.4
Eta
[%]
40
20
Eta
0.0
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m³/h]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Q [l/s]
Voltage [V]
NSBasic 3-40
1x220-240
P1
P2
P2
Max.
[kW] [kW] [hp]
NSBasic 3-40 3x220-240/380-415
Pump
type
NSBasic 3-40
36
In
Capacitor
[A]
[µF] [Vc]
1.2
0.75
1
5.5
20
450
1.2
0.75
1
3.8/2.2
-
-
0
Dimensions [mm]
DNA
A
B
C
D
E
F
G
I
H
H1
H2
342
180
76
148
72
15
148
9.5
235
100
135
Rp 1
10
DNM
Rp 1
20
30
40
50
60
70
80
Packing dimensions
[mm]
L/A
L/B
L/H
392
232
262
90
TM02 9015 1304
Electrical data
Pump
type
Q [l/min]
Vol
[m3]
Weight
[kg]
0.024
16.1
NSBasic
Technical data
NSBasic 5-50
0
4
0
H
[m]
50
400
40
300
30
200
20
100
10
0
0
TM002 9088 1804
P
[kPa]
P2
[hp]
8
12
4
16
8
20
12
24
16
28
20
32
24
Q [US GPM]
28
Q [IMP GPM]
H
[ft]
160
120
80
40
0
0
P2
[kW]
1.6
1
2
3
4
5
6
7
Q [m³/h]
Eta
[%]
40
P2
1.6
0.8
0.0
0.8
20
Eta
0.0
0
0
1
2
3
4
0.0 0.2 0.4 0.6 0.8 1.0 1.2
5
1.4
6
7
1.6 1.8 2.0
Q [m³/h]
2.2 Q [l/s]
NSBasic 5-50
P1
P2
P2
Max.
[kW] [kW] [hp]
Voltage [V]
1x220-240
NSBasic 5-50 3x220-240/380-415
Pump
type
In
Capacitor
[A]
[µF] [Vc]
8.3
31.5 450
1.9
1.1
1.5
2.0
1.1
1.5 6.0/3.5
-
0
10 20 30 40 50 60 70 80 90 100 110 120 Q [l/min]
-
Dimensions [mm]
Phase
TM02 9016 1304
Electrical data
Pump
type
DNA
A
B
C
D
E
F
G
I
H
H1
H2
Packing dimensions
[mm]
DNM
L/A
L/B
L/H
Vol
[m3]
Weight
[kg]
NSBasic 5-50
1
370
210
75
144
69
15
165
11.5
268
118
150
Rp 1¼
Rp 1
415
235
295
0.029
23.3
NSBasic 5-50
3
370
210
75
144
69
15
165
11.5
268
118
150
Rp 1¼
Rp 1
415
234
295
0.029
23.8
NSBasic 5-60
0
4
0
8
4
12
8
16
20
12
24
16
28
20
32
24
36
28
40
32
Q [US GPM]
P
[kPa]
H
[m]
Q [IMP GPM]
H
[ft]
600
60
200
400
40
200
20
0
0
P2
[hp]
2
1
0
120
80
40
0
0
P2
[kW]
2
1
2
3
4
5
6
7
8
9
Q [m³/h]
P2
1
Eta
[%]
40
20
Eta
0
0
0
0.0
1
2
3
0.8
0.4
4
5
1.2
6
1.6
7
2.0
8
9
2.4
Q [m³/h]
Q [l/s]
TM02 9017 1304
TM02 9088 1804
160
Electrical data
Pump
type
NSBasic 5-60
P1
P2
P2
Max.
[kW] [kW] [hp]
Voltage [V]
1x220-240
NSBasic 5-60 3x220-240/380-415
Pump
type
NSBasic 5-60
In
Capacitor
[A]
[µF] [Vc]
2.7
1.8
2.5
12.8
2.5
1.8
2.5 8.4/4.8
40
450
-
-
0
Dimensions [mm]
DNA
A
B
C
D
E
F
G
I
H
H1
H2
370
210
75
144
69
15
165
11.5
268
118
150
Rp 1¼
20
DNM
Rp 1
40
60
80
100
120
Packing dimensions
[mm]
L/A
L/B
L/H
415
234
295
140
Q [l/min]
Vol
[m3]
Weight
[kg]
0.032
23.8
37
NSBasic
Technical data
NSBasic 6-30
0
TM02 9090 1804
0
P
[kPa]
400
H
[m]
300
30
200
20
100
10
0
0
P2
[hp]
4
8
4
12
8
16 20 24 28 32 36 40 44 48
12
16
20
24
28
32
36
40
Q [US GPM]
Q [IMP GPM]
H
[ft]
40
P2
[kW]
1.6
1.6
0.8
0.0
120
80
40
0
0
1
2
3
4
5
6
7
8
9
10
11 Q [m³/h]
P2
0.8
Eta
[%]
40
20
Eta
0.0
0
0
0.0
1
2
3
0.8
0.4
4
5
6
1.2
1.6
7
8
9
2.0
2.4
10 11 Q [m³/h]
2.8
Q [l/s]
Pump
type
NSBasic 6-30
P1
P2
P2
Max.
[kW] [kW] [hp]
Voltage
[V]
1x220-240V
In
Capacitor
[A]
[µF] [Vc]
1.56
1.1
1.5
7.1
25
450
3x220-240/380-415 1.56
1.1
1.5
5.4/3.1
-
-
Pump
type
NSBasic 6-30
0
Dimensions [mm]
DNA
A
B
C
E
F
G
I
H
H1
387
205
88
179
20
145
11
233
108
20
40
60
100
120
140
160
180Q [l/min]
Packing dimensions
[mm]
DNM
Rp 1½
80
Rp 1
L/A
L/B
L/H
415
234
295
TM02 9018 1304
Electrical data
Vol
[m3]
Weight
[kg]
0.028
21.5
NSBasic 6-40
0
0
P
[kPa]
400
H
[m]
300
30
200
20
100
10
TM02 9090 1804
8
4
12
8
16 20 24 28 32 36 40 44 48
12
16
20
24
28
32
36
40
Q [US GPM]
Q [IMP GPM]
H
[ft]
40
0
P2
[hp]
4
120
80
40
0
P2
[kW]
1.6
1.6
0.8
0.0
0
0
1
2
3
4
5
6
7
8
9
10
11 Q [m³/h]
P2
0.8
Eta
[%]
40
20
Eta
0.0
0
0
0.0
1
2
0.4
3
0.8
4
5
6
1.2
1.6
7
8
9
2.0
2.4
10 11 Q [m³/h]
2.8
Q [l/s]
Pump
type
NSBasic 6-40
Voltage
[V]
P1
P2
P2
Max.
[kW] [kW] [hp]
38
Capacitor
[A]
[µF] [Vc]
1x220-240V
2
1.85
2.5
9
40
450
3x220-240/
380-415
2.0
1.85
2.5
6.2/3.6
-
-
0
Dimensions [mm]
Pump type
NSBasic 6-40
In
20
DNA
DNM
40
60
80
100
120
140
Packing dimensions
[mm]
L/H
160
TM02 9019 1304
Electrical data
180Q [l/min]
Vol
[m3]
Weight
[kg]
A
B
C
E
F
G
I
H
H1
L/A
L/B
461
205
88
179
20
145
11
233
108
Rp 1½
Rp 1
510
234
285
0.034
25.9
387
205
88
179
20
145
11
233
108
Rp 1½
Rp 1
415
234
295
0.028
22
KPBasic
KPBasic
Performance range
p
[kPa]
H
[m]
KPBasic
10.5
100
10.0
50 Hz
600 (A)
9.5
90
9.0
8.5
80
8.0
7.5
70
7.0
300 A
6.5
60
6.0
200
5.5
50
5.0
4.5
40
4.0
3.5
30
3.0
2.5
20
2.0
1.5
10
1.0
0.5
0.0
0
0.0
1
2
0.5
3
4
1.0
5
6
1.5
7
2.0
8
9
2.5
10
11
3.0
12
13
3.5
14
4.0
15
16
4.5
17 Q [m³/h]
Q [l/s]
TM02 8937 1804
0
39
KPBasic
General data
KPBasic
KPBasic 200:
Supplied standard with 10 metres
of H05 RN-F power cable.
KPBasic 300 A:
Supplied standard with 10 metres
of H05 RN-F power cable.
Note: 5 m cable om request.
Supplied standard with 10 metres
of H07 RN-F power cable.
KPBasic 600:
KPBasic 600 A:
Supplied standard with 10 metres
of H07 RN-F power cable.
Note: 5m cable on request.
Degree of protection: IP 68
Insulation class:
F
Gr7913
Manufactured according to standard EN 60335-2-41.
Standard voltage:
1 x 220-240V, 50 Hz
3 x 380-415V, 50 Hz.
Applications
The submersible pump from the KPBasic series is
designed mainly for automatically operated fixed applications in domestic use, draining basements and
garages which are subject to flooding.
Descriptions and materials
Thanks to its compact, easy to handle design, it can also
be used as a portable pump for emergencies such as
lifting water from tanks or rivers, emptying swimming
pools, fountains, excavations and underpasses.
It is also ideal for gardening and hobbies in general.
The level switch allows fixed installation and guarantees
automatic pump operation.
Table of performance ranges and
possible applications
KPBasic
DNM connections
Rp 1¼
Flow rate Q [m3/h]
Max. 16
Max. 10.8
o
Temperature t [ C]
29
Max. +40
Rain water
z
Clean waste water
z
1
78
Constructional features
Pump
Water-resistant technopolymer pump body, impeller,
top body and suction grid. Stainless steel motor casing,
rotor shaft and screws.
Triple "O" ring seals interposed with oil chamber.
40
54
73
79 32
Pos.
4
Descriptions
Materials
1
Pump body
Noryl GFN 2
4
impeller
Noryl GFN 2
Motor
29
O-ring gasket
NBR
Continous duty submersible induction motor.
Stator fitted in an airtight stainless steel casing covered
by a top body which encases cabling, microswitch and
capacitor. Rotor mounted on oversized greased sealedfor-life ball bearings selected to guarantee silent
running and long life. Built-in thermal and current overload protection and a capacitor which is permanently in
circuit in the single-phase version.
32
Stop ring
Stainless steel 12E
Motor
- Top body
Stainless steel AISI 304
X5 CrNi 1810
- Shaft
Stainless steel AISI 304
X5 CrNi 1810
78
Pressure disc
Noryl GFN 2
79
Suction grid
Noryl GFN 2
54
TM02 8468 3204
Head H [m]
KPBasic
Technical data
Technical data
Operation range:
Liquid quality requirements:
From 1 to 16 m3/h with head up to 10.2 metres
Grey water without fibres
Granulometric passage though the suction grid:
KPBasic 200
KPBasic 300A
KPBasic 600
KPBasic 600A
5 mm
10 mm
10 mm
10 mm
Minimum draught depth:
KPBasic 200
KPBasic 300A
KPBasic 600
KPBasic 600A
8 mm
85 mm
38 mm
175 mm
Liquid temperature range:
Maximum immersion:
Maximum dry running time:
From 0°C to +35°C
7 metres
1 minute
Automatic float switch:
Type name extension: A
Special versionson request:
Other voltages and/or frequencies
Installation:
Fixed or portable in a vertical position.
The minimum pit dimensions for fixed installation with automatic
operation are indicated in the drawing.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.
Curve tolerance according to ISO 9906, Annex A.
KPBasic 600 A
Minimum dimension for the pit for KPBasic 300 A with
automatic float switch
Minimum dimension for the pit for KPBasic 600 A with
automatic float switch
400
TM02 9101 1804
400
TM02 9100 1804
500
400
KPBasic 300 A
41
KPBasic
Technical data
0
4
0
P
[kPa]
80
8
4
KPBasic 300A
12
8
16
20
12
24
16
28
20
32
24
36
28
40
32
44
0
Q [US GPM]
36
0
Q [IMP GPM]
H
[ft]
H
[m]
4
P
[kPa]
80
8 12 16 20 24 28 32 36 40 44 48 52 56
4
8
12
16
20
24
28
32
H
[m]
Q [US GPM]
36 40 44 48 Q [IMP GPM]
H
[ft]
8
25
8
25
60
6
20
60
6
20
40
4
15
40
4
20
2
0
0
10
20
2
5
0
0
0
0.2
0.1
0.0
P2
[kW]
0.2
0
1
2
3
4
5
6
7
8
9
10 Q [m³/h]
P2
0.1
20
Eta
0.0
0
0.0
0
1
0
2
3
0.8
0.4
20
40
4
5
6
1.2
1.6
60
80
7
8
9
2.0
2.4
100
120
140
P2
[hp]
Eta
[%]
40
10 Q [m³/h]
2.8 Q [l/s]
160 Q [l/min]
TM02 9020 1304
P2
[hp]
0.2
0.1
0.0
P2
[kW]
0.2
15
10
5
0
0
1
2
3
4
5
6
7
8
9
10 11 12
Q [m³/h]
P2
0.1
Eta
[%]
40
20
Eta
0.0
0
0 1 2 3
0.0 0.4 0.8
0
20
40
4 5 6
1.2
1.6
60
7 8 9
2.0 2.4
10 11 12 Q [m³/h]
2.8 3.2 3.6 Q [l/s]
80 100 120 140 160 180 200 Q [l/min]
TM02 9021 1304
KPBasic 200
Liv.max.
Liv.min.
H
TM02 8466 0204
H2
H1
KPBasic 200, KPBasic 300A
E
B
A
D
Electrical data
Pump
type
P2
P2
In
Capacitor
Voltage [V]
P1
Max.
[W]
[kW]
[hp]
[A]
[µF]
[Vc]
KPBasic 200
1x220-240
350
0.22
0.3
1.5
8
450
KPBasic 300A
1x220-240
350
0.22
0.3
1.5
8
450
Liv. min.
Liv. max.
A
B
D
E
H
H1
H2
[mm]
[mm]
KPBasic 200
185
140
225
82
266
390
38,5
100
350
KPBasic 300A
185
140
225
82
275
390
47,5
100
350
Pump
type
42
Dimensions [mm]
Packing dimensions [mm]
L/A
L/B
L/H
Vol
[m3]
Rp 1¼
207
227
312
0.016
4.5
Rp 1¼
207
227
312
0.016
4.6
DNM
Weight
[kg]
KPBasic
Technical data
KPBasic 600 (A)
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q [IMP GPM]
H
[ft]
2
0
0
P2 0
[kW]
0.6
0.4
0.2
0.0
0
0.0
0
2
4
6
8
10
12
14
16
Q [m³/h]
P2
Eta
2
0.5
4
1.0
40
6
1.5
80
8
2.0
2.5
120
10
12
14
3.0 3.5 4.0
160
200
16
4.5
240
Eta
[%]
30
20
10
0
Q [m³/h]
Q [l/s]
Q [l/min]
E
TM02 8466 0204
4
20
H2
6
40
30
25
20
15
10
5
0
H1
8
Liv.max.
10 15 20 25 30 35 40 45 50 55 60
TM02 9022 1304
80
60
P2
[hp]
0.8
0.6
0.4
0.2
0.0
5
H
[m]
10
Liv.min.
0
P
[kPa]
Q [US GPM]
H
0
KPBasic 600 (A)
B
A
D
Electrical data
Pump
type
Voltage [V]
P1
Max.
[W]
P2
[kW]
In
Capacitor
[hp]
[A]
[µF]
[Vc]
P2
KPBasic 600
1x220-240
800
0.55
0.75
3.4
14
450
KPBasic 600A
1x220-240
800
0.55
0.75
3.4
14
450
KPBasic 600
3x380-415
800
0.55
0.75
3.4
-
-
Liv. min.
Liv. max.
A
B
D
E
H
H1
H2
[mm]
[mm]
KPBasic 600
200
160
225
90
376
490
73
200
450
KPBasic 600A
200
160
225
90
376
490
73
200
450
Pump
type
Dimensions [mm]
Packing dimensions [mm]
L/A
L/B
L/H
Vol
[m3]
Rp 1 ¼
207
227
422
0.021
7
Rp 1 ¼
207
227
422
0.021
6.7
DNM
Weight
[kg]
43
PFBasic
PFBasic
Performance range
p
[kPa]
600
H
[m]
55
500
PF(P)Basic
50 Hz
60
PFPBasic 2-50
50
PFBasic 2-50
45
400
40
35
300
PFBasic 1-30
30
25
200
20
15
100
10
5
0
0.0
0.0
44
0.2
0.4
0.1
0.6
0.8
0.2
1.0
0.3
1.2
1.4
0.4
1.6
1.8
0.5
2.0
2.2
0.6
2.4
2.6
0.7
2.8
Q [m³/h]
0.8
Q [l/s]
TM02 8935 1804
0
PFBasic
General data
PFBasic
1
28
Applications
16
TM02 9071 1704
GR7901
4
7
Material specification
Peripheral centrifugal pump with compact dimensions.
Able to generate high heads and suitable for domestic
installations, water supply systems, light gardening
applications, draining and filling cisterns, as well as light
industrial uses such as feeding pressurized boilers (anticondensation).
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200
4
Impeller
Brass PCu Zn 40 Pb2 5705-65
7
Shaft
Stainless steel AISI 416
X12 CrS 13
16
Mechanical seal
Carbon/ceramic
28
O-ring gasket
NBR rubber
Constructional features
Pump
Cast iron pump body and motor support with brass wear
disc.
Brass impeller. Carbon/ceramic mechanical seal.
Motor
Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings to ensure silent running and long life.
The motor incorporates a built-in thermal and current
overload protection as well as a capacitor, switched on
permanently.
Manufactured according to standard EN 60335-2-41.
Motor protection:
IP 44
Terminal box protection:
IP 55
Insulation class:
F
Standard voltage:
Single-phase 220-240 V,
50 Hz.
Other voltages and frequencies are available on request.
45
PFBasic
Technical data
Technical data
Operating range:
From 0.3 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid:
Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water.
Liquid temperature range:
from 0°C to +35°C for domestic use (EN 60335-2-41)
From –10°C to +50°C for other uses.
Maximum ambient temperature: +40°C
Maximum operating pressure:
- PFBasic 1-30: 6 bar (600 kPa)
- PFBasic 2-50: 10 bar (1000 kPa)
Installation:
Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.
p
[kPa]
H
[m]
56
480
48
400
40
PFBasic
2-50
52
50 Hz
ISO 9906 Annex A
44
36
320
1-30
32
28
240
24
20
160
16
12
80
8
0
0
4
0.4
0.0
0.8
1.2
0.2
1.6
2.0
0.4
2.4 Q [m³/h]
0.6
TM02 6757 1304
TM02 9091 1804
0.0
Q [l/s]
Electrical data
Capacitor
Model
Voltage [V]
P1 max.
[kW]
P2
[kW]
P2
[hp]
In
[A]
[µF]
[Vc]
PFBasic 1-30
1 x 220-240
0.47
0.3
0.4
2
8
450
PFBasic 2-50
1 x 220-240
0.86
0.6
0.8
3.8
12.5
450
Dimensions and weights
Model
46
A
B
B1
C
E
F
G
I
H
H1
H2
DNA
DNM
Packing dimensions [mm]
L/A
L/B
L/H
Volume
[m 3]
Weight
[kg]
PFBasic 1-30
228
132
165
22
46
-
65
8
158
103
138
Rp 1
Rp 1
259
164
197
0.008
5.3
PFBasic 2-50
255
130
-
26
106
80
100
7
186
108
153
Rp 1
Rp 1
271
176
209
0.01
7.5
PFPBasic
General data
PFPBasic 2-50
Applications
3 28
4
7
TM02 9072 1704
Gr7900General data
1
16
Materials
Self-priming pump with side liquid channel and starshaped impeller, with excellent suction capacities even
in unfavourable operating conditions such as the presence of air bubbles or lack of continuity in the sucked
liquid. Used in domestic, agricultural civil and industrial
installations.
Constructional features
Pump
Pos.
Description
Material
1
Pump body
Cast iron EN-GJL-200,
with brass wear ring
PCuZn 40 Pb2 5705/65
3
Motor support
Brass PCu Zn 40 Pb2 5705/65
4
Impeller
Brass PCu Zn 40 Pb2 5705/65
7
Shaft
Stainless steel AISI 416
X12 CrS 13
16
Mechanical seal
Carbon/ceramic
28
O-ring gasket
FKM
Cast iron pump body with brass pressure disc.
Motor support and impeller completely made of brass,
to avoid the risk of blockage.
Carbon/ceramic mechanical seal.
Stainless steel motor shaft.
Motor
Asynchronous motor, cooled by external fan. Rotor
mounted on oversized, greased and sealed-for-life ball
bearings to ensure quiet operation and long life.
The single-phase version has built-in thermal and
current overload protection.
Manufactured according to standard EN60335-2-41.
Motor protection:
IP 44
IP 55 terminal board protection
Insulation class:
F
Standard voltage:
Single-phase 220-240 V, 50 Hz.
Other voltages and frequencies are
available on request.
47
PFPBasic
Technical data
Operating conditions
Operating range:
From 0.5 to 2.7 m3/h with heads up to 53 metres.
Pumped liquid:
Clean, free from solids or abrasive substances, non-aggressive, noncrystallized,
chemically neutral, similar to the characteristics of water.
Liquid temperature range:
From –10°C to +80°C
Maximum ambient temperature: +40°C
Maximum operating pressure:
10 bar (1000 kPa)
Installation:
Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3.
Curve tolerances according to ISO 9906, annex A.
p
[kPa]
H
[m]
56
PFPBasic 2-50
52
50 Hz
480
48
ISO 9906 Annex A
400
40
44
36
320
32
28
240
24
20
160
16
12
80
8
0
0
TM02 9092 1804
0.0 0.4 0.8
0.0
1.2
0.2
1.6
0.4
2.0
0.6
2.4
2.8 Q [m³/h]
0.8 Q [l/s]
TM02 6758 1304
4
Electrical data
PFPBasic 2-50
Capacitor
Voltage [V]
P1 max.
[kW]
P2
[kW]
P2
[hp]
In
[A]
µF
Vc
1 x 220-240
1.05
0.75
1
4.7
20
450
Model
Dimensions and weights
Model
PFPBasic 2-50
48
A
B
C
E
F
G
I
H
H1
H2
DNA
DNM
301
142
38
136
90
112
7
206
146
187
Rp 1
Rp 1
Packing dimensions [mm]
L/A
L/B
L/H
Volume
[m3]
Weight
[kg]
406
267
402
0.044
10.7
49
50
51
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
96548246 0804 - c1
GB
Subject to alterations.
GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark
Telephone: +45 87 50 14 00.
www.grundfos.com

Similar documents