Grundfos Basic Databook 13072KB Feb 18 2013 10:33:57 AM
Transcription
Grundfos Basic Databook 13072KB Feb 18 2013 10:33:57 AM
GRUNDFOS DATA BOOKLET Grundfos Basic 50 Hz Contents JPBasic Performance range General data Applications Constructional features Material specification Technical data Curve conditions CHBasic PS Page Page Page Page Page Page Page 3 4 4 4 5 5 5 Page Page Page Page Page 10 10 10 10 11 Page 12 JPBasic PS General data JPBasic PC General data Applications Operation Technical data Page Page Page Page 13 13 13 15 Page Page Page Page Page Page 16 16 16 16 17 18 Page Page Page Page Page Page Page 19 20 20 20 20 21 21 Page Page Page Page Page Page 24 24 24 24 25 25 JDBasic General data Applications Constructional features Material specification Technical data Instructions for conversion CHBasic Performance range General data Applications Constructional features Material specification Technical data Curve conditions CHBasic PT General data Applications Constructional features Material specification Technical data Curve conditions 2 Page Page Page Page Page Page 26 26 26 26 27 27 Page Page Page Page Page Page Page 28 28 28 28 29 30 30 Page Page Page Page Page Page Page Page Page Page Page Page 31 32 32 32 32 32 33 35 35 35 35 36 Page Page Page Page Page Page 39 40 40 40 41 41 Page Page Page Page Page Page 44 45 45 45 45 46 Page Page Page Page Page 47 47 47 47 48 CHBasic PC JPBasic PT General data Applications Constructional features Material specification Technical data General data Applications Constructional features Material specification Technical data Curve conditions General data Applications Operation Constructional features Material specification Technical data Curve conditions NSBasic Performance range General data NSBasic single impeller pumps Applications Constructional features Material specification Technical data NSBasic twin impeller pumps Applications Constructional features Material specification Technical data KPBasic Performance range General data Applications Constructional features Technical data Curve conditions PFBasic Performance range General data Applications Constructional features Material specification Technical data PFPBasic General data Applications Constructional features Materials Technical data JPBasic JPBasic Performance range p [kPa] H [m] JPBasic 65 600 50 Hz 60 55 500 50 45 400 40 5 35 300 200 7 30 10 25 4 20 3 9 15 2 100 10 5 0 0 0.0 1 2 0.5 3 4 1.0 5 6 1.5 7 2.0 8 9 2.5 10 Q [m³/h] 3.0 Q [l/s] TM02 8936 1804 0 3 JPBasic General data JPBasic 9, JPBasic 10 Applications Gr7921 Gr7903 JPBasic 2, JPBasic 3, JPBasic 4 JPBasic 5, JPBasic 7 Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small sandy impurities in the water. Used especially for supplying water to domestic systems. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever selfpriming operation is necessary. Constructional features Cast iron pump body and motor support in cast iron treated against corrosion also on the inner surface. Technopolymer impeller, diffuser venturi tube and sand tube. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Asynchronous motor cooled with external fan. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz. 4 Gr7917 Pump JPBasic Technical data Material specification Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 * 8 Venturi tube and nozzle Noryl GFN 2 16 Mechanical seal Carbon/Ceramic 28 O-Ring gasket NBR 8 1 6 28 3 * JPBasic 1, JPBasic 2, JPBasic 4: X 12 Cr S 13 16 4 7 TM02 8459 0204 Pos. Technical data Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum suction depth: 8 metres Maximum operating pressure: JPBasic 2, JPBasic 3, JPBasic 4: JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10: Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. 6 bar (600 kPa) 7.5 bar (750 kPa) Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. 5 Technical data JPBasic JPBasic 2 0 A A1 P [kPa] 400 H [m] 240 TM02 8444 0204 G B Voltage [V] 1 x 220-240 JPBasic 2 P2 In Capacitor Max. [kW] [kW] [hp] [A] [µF] [Vc] 3.12 12.5 450 0.72 0.44 0.6 3 x 220-240/380-415 0.67 0.44 0.6 2.1/1.2 - JPBasic 2 10 Q [IMP GPM] H [ft] 100 80 20 160 60 8 15 5 6 7 4 3 2 40 10 80 20 5 0 0 0.4 0 0.8 0.2 1.2 1.6 2.0 0.4 10 2.4 Q [m³/h] Q [l/s] 40 Q [l/min] 0.6 20 30 - Packing dimensions [mm] Dimensions [mm] Pump type 8 Q [US GPM] 25 Electrical data P2 6 12 120 0.0 0.0 P1 4 10 30 0 Pump type 2 8 35 H3 I F E 0 6 40 320 H DNA DNM 4 TM02 9023 1304 C 2 A A1 B C E F G H H3 I DNA DNM L/A L/B L/H 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 Vol [m3] Weight [kg] 0.027 10.9 JPBasic 3 0 C P [kPa] H [m] 45 400 40 TM02 8444 0204 H3 320 I F E G B JPBasic 3 Pump type JPBasic 3 6 P1 Max. [kW] P2 [kW] 1 x 220-240 0.85 3 x 220-240/380-415 0.86 P2 Capacitor [hp] [A] [µF] [Vc] 0.6 0.8 3.8 12.5 450 0.6 0.8 2.8/1.6 - - 4 10 6 8 12 14 Q [US GPM] 10 Q [IMP GPM] H [ft] 140 120 100 80 20 160 8 60 7 6 15 5 4 3 10 80 2 40 20 5 0 0 0.0 0.0 In 8 25 240 Electrical data Voltage [V] 2 6 30 0 Pump type 0 4 35 H DNA DNM 2 0.4 0 0.8 0.2 10 1.2 1.6 0.4 20 2.0 2.4 0.6 30 2.8 0.8 40 50 Q [l/min] Packing dimensions [mm] Dimensions [mm] Q [m³/h] Q [l/s] TM02 9024 1304 A A1 A A1 B C E F G H H3 I DNA DNM L/A L/B L/H 395 390 178 108 192 14 111 200 144 9 Rp 1 Rp 1 470 240 240 Vol [m3] Weight [kg] 0.027 11 Technical data JPBasic JPBasic 4 0 C DNA DNM P [kPa] H [m] 50 400 40 300 30 2 0 4 2 6 8 4 10 6 8 12 14 Q [US GPM] 10 Q [IMP GPM] H [ft] 160 H 45 140 120 I F E TM02 8444 0204 H3 35 G B 200 1 x 220-240 JPBasic 4 P2 6 100 [kW] [hp] In Capacitor [A] [µF] [Vc] 1.13 0.75 1 5.1 16 450 3 x 220-240/380-415 1.04 0.75 1 3.3/1.9 - - 4 60 2 3 40 20 5 0 0 0.0 0.0 P2 5 10 0.4 0 0.8 0.2 1.2 10 1.6 0.4 20 2.0 2.4 0.6 30 2.8 0.8 40 Q [m³/h] Q [l/s] 50 Q [l/min] Packing dimensions [mm] Dimensions [mm] Pump type JPBasic 4 P1 Max. [kW] 7 15 Electrical data Voltage [V] 80 8 20 0 Pump type 100 25 TM02 9025 1304 A A1 A A1 B C E F G H H3 I DNA DNM L/A L/B L/H 414 409 178 108 197 14 111 213 144 9 Rp 1 Rp 1 470 240 240 Vol [m3] Weight [kg] 0.027 16.2 JPBasic 9 0 A 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM] DNA C P [kPa] 400 H TM02 8464 0204 G B 200 100 Pump type JPBasic 9 16 20 24 28 32 36 40 Q [IMP GPM] H [ft] 120 30 100 25 80 20 60 40 10 8 P2 P2 In Max. [kW] [kW] [hp] [A] [µF] [Vc] 1 x 220-240 2 1.5 2 9 31.5 450 3 x 220-240/ 380-415 2 1.5 2 6.8/3.9 - - 7 5 Electrical data JPBasic 9 12 40 6 5 4 0 0 0.0 P1 Voltage [V] 8 15 0 Pump type 4 1 2 0.4 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 20 3 2 1 0 10 11 Q [m³/h] 2.8 Q [l/s] TM02 9028 1304 H1 Iø F 0 35 300 E H [m] Capacitor 0 20 40 60 80 100 120 140 160 Packing dimensions [mm] Dimensions [mm] A B C E F G Iø H H1 DNA DNM L/A L/B L/H 521 214 151 282 20 160 11 227 175 Rp 1 ½ Rp 1 ¼ 612 248 279 180Q [l/min] Vol [m3] Weight [kg] 0.042 27 7 Technical data JPBasic JPBasic 10 0 A A1 DNA DNM P [kPa] H [m] 50 400 40 300 30 0 8 4 12 8 16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 Q [US GPM] 40 Q [IMP GPM] H [ft] 160 H3 H 45 140 120 I F E TM02 8464 0204 35 G B 100 25 200 80 8 20 60 15 100 10 0 P2 P2 In Capacitor Max. [kW] [kW] [hp] [A] [µF] [Vc] 1 x 220-240 2.7 2.2 3 12 40 450 3 x 220-240/ 380-415 2.7 2.2 3 8.5/4.9 - - Voltage [V] JPBasic 10 JPBasic 10 2 1 20 0 0 1 2 3 0.8 0.4 20 40 4 5 6 1.2 1.6 60 80 7 8 9 2.0 2.4 100 120 140 10 11 Q [m³/h] 2.8 Q [l/s] 160 180Q [l/min] Packing dimensions [mm] Dimensions [mm] Pump type 3 4 0 0 0.0 P1 6 5 Electrical data Pump type 40 7 5 A B C E F G IØ H H1 DNA DNM L/A L/B L/H 595 214 151 282 20 160 11 235 175 Rp 1 ½ Rp 1 ¼ 657 248 279 TM02 9029 1304 C 4 Vol [m3] Weight [kg] 0.045 31.5 JPBasic 5 0 B A C DNA DNM Iø X A E G TM02 8462 0204 H2 H1 H1 DNE H H V Voltage [V] JPBasic 5 Pump type JPBasic 5 8 P1 Max. [kW] P2 P2 [kW] [hp] Capacitor [A] [µF] [Vc] 31.5 450 1 x 220-240 1.6 1.1 1.5 7.2 3 x 220-240/ 380-415 1.6 1.1 1.5 5.2/3.0 - 8 10 16 40 30 200 20 12 18 14 20 Q [US GPM] 160 16 120 6 8 7 5 4 80 3 2 1 100 10 0 0 40 0 0.0 0.0 In 14 60 Electrical data Pump type 12 600 300 6 10 Q [IMP GPM] H [ft] 200 50 4 8 H [m] 500 2 6 P [kPa] 400 0 4 0 0.5 1.0 1.5 0.2 0.4 10 20 2.0 2.5 3.0 0.6 0.8 30 40 50 3.5 4.0 4.5 Q [m³/h] 1.0 1.2 Q [l/s] 60 70 TM02 9026 1304 Z 2 Q [l/min] - Packing dimensions [mm] Dimensions [mm] A B C E F G Iø H H1 DNA DNM L/A L/B L/H 558 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 612 248 279 Vol [m3] Weight [kg] 0.045 31 Technical data JPBasic JPBasic 7 0 Z DNA DNM TM02 8462 0204 H1 H2 DNE H H H1 Iø X A 8 12 16 20 24 28 32 Q [US GPM] B A C V 4 E G P [kPa] H [m] 600 60 Q [IMP GPM] H [ft] 200 160 500 50 400 40 300 30 200 20 100 10 0 4 8 12 16 20 24 28 8 120 7 6 5 4 3 80 2 40 1 JPBasic 7 Pump type JPBasic 7 P1 P2 P2 In Capacitor Max. [kW] [kW] [hp] [A] [µF] [Vc] 1 x 220-240 2.2 1.85 2.5 10 40 450 3 x 220-240/ 380-415 2.2 1.85 2.5 6.9/4.0 - - Voltage [V] 0 0 0.0 Electrical data Pump type 0 0 1 2 3 0.8 0.4 20 40 4 5 1.2 60 80 6 1.6 7 2.0 100 Packing dimensions [mm] Dimensions [mm] A B C E F G Iø H H1 DNA DNM L/A L/B L/H 632 210 221 350 20 145 11 255 158 Rp 1 ¼ Rp 1 657 248 279 Q [m³/h] Q [l/s] TM02 9027 1304 0 120 Q [l/min] Vol [m3] Weight [kg] 0.045 35 9 JPBasic PT General data JPBasic PT Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top. Applications The characteristics of the JPBasic-pumps are that they are self-priming electric pumps which can operate even when there is air, gas and small quantities of sand in the water. The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets. Constructional features Pump Cast iron pump body and motor support. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel pressure discs. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings, to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41. 10 6 28 16 4 3 7 Material specification Automatic water lifting and pressure boosting sets, particularly suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. Motor protection: Insulation class: Standard voltage: 1 TM02 8459 3204 TM02 9060 1704General data 8 IP 44 F 1 x 220-240 V, 50 Hz. Description Pos. Material 1 Pump body Cast iron (EN-GJL-200) 3 Support Cast iron (EN-GJL-200) 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft Stainless steel AISI 416 X12 CrS 13 8 Venturi tupe and nozzle Noryl GFN 2 16 Mechanical seal Carbon/Ceramic 28 O-Ring gasket NBR Components in contact with the liquid. JPBasic PT Technical data Technical data Operating range: Up to 3.6 m3/h with head up to 51 metres. Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum operating pressure: 6 bar (600 kPa) Installation: Fixed in a horizontal position. JPBasic PT D H1 0 P [kPa] H [m] 50 400 40 2 0 4 2 6 4 8 10 6 45 8 L TM02 9068 1704 H B A 14 Q [US GPM] 10 Q [IMP GPM] H [ft] 160 140 JPBasic 2 JPBasic 3 35 300 12 120 JPBasic 4 30 100 25 200 80 20 60 15 100 40 10 20 5 0 0 0 0.0 0.0 0.4 0.8 0.2 1.2 1.6 0.4 2.0 2.4 0.6 2.8 0.8 Q [m³/h] Q [l/s] TM02 8940 1704 A1 Electrical data Voltage [V] P1 Max. [kW] [hp] [A] [µF] [Vc] JPBasic 2 PT 1 x 220-240 0.72 0.44 3.12 12.5 450 JPBasic 3 PT 1 x 220-240 0.85 0.6 3.8 12.5 450 JPBasic 4 PT 1 x 220-240 1.13 0.75 5.1 16 450 Pump type Pump type P1 In 0 Capacitor Dimensions [mm] 10 Rp 1 576 366 554 0.107 16.1 Rp 1 576 366 554 0.107 16.2 Rp 1 576 366 554 0.107 21.4 Rp 1 Rp 1 332 Rp 1 H H1 L JPBasic 2 PT 550 390 270 282 290 232 JPBasic 3 PT 550 390 270 282 290 232 JPBasic 4 PT 550 409 270 282 290 232 Packing dimensions [mm] Vol [m3] 332 D 50 Q [l/min] L/H 332 B 40 L/B DNM A1 30 L/A DNA A 20 Weight [kg] 11 JPBasic PS General data JPBasic PS Auto pressure units Single-phase version: Self-priming centrifugal pump equipped with pressure gauge, pressure switch (PS), power supply cable with plug and three-way brass connector for connecting to a tank. Gr7908 JPBasic-PS Pump type JPBasic 2 PS JPBasic 3 PS JPBasic 4 PS JPBasic 5 PS Voltage [V] P1 Max. [kW] Electrical data P2 P2 In Max. [kW] [hp] 1 x 220-240 0.72 0.44 1 x 220-240 0.85 0.6 1 x 220-240 1.13 0.75 1 x 220-240 1.6 1.1 0.6 0.8 1.0 1.5 12 [A] [Vc] 3.12 3.8 5.1 7.2 12.5 12.5 16 31.5 450 450 450 450 Dimensions [mm] Pump type JPBasic 2 PS JPBasic 3 PS JPBasic 4 PS JPBasic 5 PS Capacitor [µF] A 395 395 414 563 A1 390 390 390 556 B 282 282 282 217 C 108 108 108 160 D 196 196 196 109 E 192 192 192 329 F 14 14 14 15 G 111 111 111 145 Iø 11 H 232 232 232 312 H1 199 199 199 279 H2 200 200 221 H3 144 144 144 159 I 9 9 9 - DNA DNM Rp 1 Rp 1 Rp 1 Rp 1 ¼ Rp 1 Rp 1 Rp 1 Rp 1 Packing dimensions [mm] L/A L/B L/H 486 366 232 486 366 232 486 366 232 600 236 267 Vol [m3] Weight [kg] 0.041 0.041 0.041 0.038 11.9 12.1 13.9 31.5 JPBasic PC General data JPBasic PC Gr7907 Self-priming centrifugal pump equipped with presscontrol (PC) and power supply cable. Applications Automatic water lifting sets, particulary suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. These are characterised by the use of JPBasic PC selfpriming centrifugal pumps which can operate even when there is air, gas and small quantities of sand in the water. They are indispensable for use in artesian wells and whereever suction difficulties arise. Operation The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations. 13 JPBasic PC Optimised management of the hydraulic installation and its components 1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up. 2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is opened the depression created in the system acts on the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up. 3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from being subjected to repeated starts caused by users opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is guaranteed by timing the stops. 4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn. 5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds. 6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect. 7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off. 8. In the event of a power cut, automatic reset as soon as the power is restored. 9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out automatically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system. 14 General data Constructional features of the pump JPBasic 3 PC, JPBasic 4 PC: Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tube. Stainless steel pressure discs and rotor shaft. Carbon/ceramic mechanical seal. Constructional features of the motor Induction motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball bearings. Built-in thermal and current oyerload protection and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41. Motor protection: Insulation class: IP 44 F. All the pumps are supplied with 0.75 metres of power cable type H05 RN-F with plug. Constructional features of the automatic control The automatic device which regulates the pump operation is basically formed of the following components: FLOW SWITCH SET: this comprises a 4-way metal union with two housings for the delivery and pressure sensors. Both their seat and the sensor capsule are structured so that no pre-calibration is required. SPRING EXPANSION TANK: manufactured in pressed and flanged stainless steel, this has been designed to ensure maximum reliability and sturdiness with minimum overall dimensions. Inside it houses a spring which operates as a pressure switch. ELECTRONIC CARD: this is composed of a printed circuit which receives signals from the sensors and manages the automatic device as indicated in the paragraph regarding operation. The commands plate with the two LEDs, green = ON, red = Alarm and the Reset button for resetting the pump is positioned on the terminal board cover. CHECK DEVICE: all automatic sets are equipped with a check valve which has been selected to ensure maximum long lasting reliability. In order to prevent operational faults in the system it is essential that the position of the valve is not changed during assembly. The automatic control is supplied pre-assembled with all the accessories. JPBasic PC Technical data Technical data Operating range: From 0.3 to 3.6 m3/h with head up to 51 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum operating pressure: 6 bar (600 kPa) Installation: Fixed in a horizontal position. JPBasic PC C 0 P [kPa] H [m] 50 400 40 2 0 4 2 6 4 8 6 H DNA 45 8 14 Q [US GPM] 10 Q [IMP GPM] H [ft] 160 140 JPBasic 3 120 JPBasic 4 30 100 TM02 9067 1704 H3 25 Iø F G E A B 200 80 20 60 15 100 40 10 20 5 0 0 0 0.0 0.0 Electrical data Pump type 12 JPBasic 2 35 300 10 Voltage [V] 0 P1 P2 P2 In Capacitor Max. [kW] [kW] [hp] [A] [µF] [Vc] JPBasic 2 PC 1 x 220-240 0.72 0.44 0.6 3.12 12.5 450 JPBasic 3 PC 1 x 220-240 0.85 0.60 0.8 3.4 12.5 450 JPBasic 4 PC 1 x 220-240 1.13 0.75 1.0 4.7 16 450 Dimensions [mm] Pump type 0.4 0.8 0.2 10 1.2 1.6 0.4 20 2.0 2.4 0.6 30 2.8 0.8 40 Q [m³/h] Q [l/s] TM02 8940 1704 DNM 50 Q [l/min] DNA DNM Packing dimensions [mm] Vol [m3] Weight [kg] A B C E F G Iø H H3 L/A L/B L/H JPBasic 2 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 14 JPBasic 3 PC 395 212 108 192 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16 JPBasic 4 PC 414 212 108 197 14 111 9 375.5 144 Rp 1 Rp 1 524 248 309 0.04 16 15 JDBasic General data JDBasic 5, JDBasic 7 TM00 9974 1097 Gr7899General data JDBasic 2, JDBasic 4 Motor Applications Self-priming centrifugal pump for suction up to 27 metres, reached by means of an ejector to be inserted in wells with a diameter of 4" or over. For use in supplying water to farmhouses and in small-scale agriculture. Asynchronous motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. Constructional features Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tupe and brass nozzle. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Ejector: Cast iron body with anti-corrosive treatment also on the inner surface. Technopolymer Venturi tube and brass nozzle. The ejector is available in 3 models (E20 - E25 - E30) to be chosen according to performance requirements. (see tables on pages 17 and 18). For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz. Material specification Description Material 1 Pump body Cast iron EN-GJL-200 2 Ejector body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 Shaft with rotor (JDBasic 2-4) Stainless steel AISI 416 X 12 Cr S 13 7 (JDBasic 5-7) AISI 303 X10 Cr NiS 18 9 16 8 Venturi Noryl GFN 2 9 Nozzle Brass 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket NBR 8 1 6 28 3 2 9 16 4 7 TM02 8456 0204 Pos. JDBasic Technical data Technical data Operating range: Up to 4.3 m3/h Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use Maximum ambient temperature: + 40°C JDBasic 2, JDBasic 4: 6 bar (600 kPa) JDBasic 5, JDBasic 7: 8 bar (800 kPa) Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. TM00 9976 1097 Maximum operating pressure: JDBasic 2, JDBasic 4 Hydraulic data (n ≈ 2850 min -1) Delivery pressure in bar Pump Ejector Suction type type depth Z 1.5 2.0 E30 G B TM02 8455 0204 X JDBasic 4 E25 E30 Dimensions [mm] DNM DNE JDBasic 2 365 180 90 202 140 9,5 225 47 92 G1¼ G1 G1 97 295 JDBasic 4 385 180 90 202 140 9,5 225 47 92 G1¼ G1 G1 97 295 B C E JDBasic 2 G I H H1 H2 P1 P2 P2 Voltage [V] Max. [kW] [kW] [hp] 1 x 220-240 0.69 0.44 0.6 3 x 220-240/ 380-415 4.0 9 1813 1080 446 33 / / 1426 720 225 / / / 15 900 326 / / / / 9 1753 1286 812 524 261 46 12 1345 965 608 356 162 0 15 1166 761 452 228 45 / 9 2386 1756 1097 515 126 / 12 1930 1190 536 87 / / 15 1459 773 252 / / / 12 / 1240 872 566 329 156 15 / 1028 701 449 255 96 18 / 785 527 302 150 15 21 / 635 374 180 39 / A H H1 [mm] [mm] [mm] Packing dimensions 0.66 0.44 0.6 Vol L/A L/B L/H [m3] [mm] [mm] [mm] x y z 243 G1 G1 G1¼ 452 218 257 0.025 13.9 243 G1 G1 G1¼ 492 224 277 0.025 16.6 Electrical data Pump type 3.5 12 Ejector DNA A 3.0 Weight [kg] E25 JDBasic 2 H1 H2 H H V Pump type 2.5 Capacity table in [l/h] A Electrical data In Capacitor [A] [µF] [Vc] 3.2 14 450 2.6/1.5 - - Pump type JDBasic 4 P1 P2 P2 Voltage [V] Max. [kW] [kW] [hp] 1 x 220-240 0.79 0.75 1 3 x 220-240/ 380-415 0.64 0.75 1 In Capacitor [A] [µF] [Vc] 3.8 16 450 2.6/1.5 - - 17 JDBasic Technical data JDBasic 5, JDBasic 7 Hydraulic data (n ≈ 2850 min -1) Pump Ejector Suction 3.0 type type depth DNM V JDBasic 5 E 20 IØ E 25 G E E 30 Z JDBasic 7 TM02 8457 0204 H H1 Dimensions [mm] Pump type A B C E G I H 3412 2769 2090 1363 586 / / / / / / 3065 2400 1719 952 143 / / / / / / 15 2643 2000 1257 495 / / / / / / / 18 2289 1593 826 / / / / / / / 15 2745 2244 1761 1257 814 435 77 / / / / 18 2465 1969 1477 997 584 218 / / / / / 21 2206 1712 1224 779 388 45 / / / / 21 1797 1615 1368 1106 861 658 472 312 163 25 / DNA DNM DNE A H H1 [mm] [mm] [mm] / / / / / 9 / 3431 2751 2033 1236 448 / / / / / 12 / 3043 2324 1554 763 0 / / / / / 15 / 2665 1936 1145 344 / / / / / / 18 / 2244 1478 675 / / / / / / 15 / 2840 2324 1806 1296 849 463 138 / / / 18 / 2535 2038 1523 1049 640286 / / / / 21 / 2267 1757 1257 817 424 91 / / / / 24 / 1970 1458 989 583 226 / / / / 21 / 1812 1671 1419 1163 919 716 531 377 226 91 24 / 1668 1549 1278 1023 791 619 445 297 156 13 27 / 1541 1395 1145 906 700 521 351 206 62 / Ejector H1 H2 0 1652 1484 1217 962 740 547 378 220 67 E 25 E 30 9 12 1520 1333 1069 841 636 448 287 139 / E 20 E 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Capaticy table [l/h] 27 C X 4.0 24 A V Delivery pressure [bar] 3.5 / / Packing dimensions [mm] x y z L/A L/B L/H Weight [kg] B A C Vol [m3] JDBasic 5 388 210 50 197 145 11 255 53 108 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 427 246 307 0.032 31 JDBasic 7 462 210 50 197 145 11 255 53 108 G1¼ G1 G1 97 295 243 G1 G1 G1¼ 522 246 307 0.039 35 Electrical data Pump type P1 P2 Electrical data P2 Voltage [V] Max. [kW] [kW] [hp] JDBasic 5 1 x 220-240 1.56 1.1 1.5 JDBasic 7 1 x 220-240 2.1 1.85 2.5 In Capacitor [A] [µF] [Vc] 7 31.5 450 8.3 40 450 Pump type P1 Max. [kW] P2 P2 [kW] [hp] [A] JDBasic 5 3 x 220-240/380-415 1.45 1.1 1.5 4.7/2.7 JDBasic 7 3 x 220-240/380-415 1.78 1.85 2.5 5.6/3.2 Voltage [V] In Instructions for conversion TM00 9980 1097 & TM00 9981 1097 Conversion from JDBasic 5, JDBasic 7 to JPBasic 5, JPBasic 7 18 Screw the nozzle (9) into the seat in the ejector body (2) and the Venturi tube (8). Position the O-rings (27) and (29) in their respective seats and fix the ejector body (2) onto the pump body (1) with the two screws (53). Conversion from JPBasic 5, JPBasic 7 to JDBasic 5, JDBasic 7 Slacken and remove the two joining screws (53) between the ejector body (2) and the pump body (1). Collect the O-rings (27) and (29). CHBasic CHBasic Performance range p [kPa] H [m] CHBasic 600 50 Hz 60 3 55 500 50 4 45 400 2 40 35 300 30 25 200 20 15 100 10 5 0 0.0 0.0 0.5 1.0 0.2 1.5 0.4 2.0 0.6 2.5 3.0 0.8 3.5 1.0 4.0 4.5 1.2 5.0 1.4 5.5 6.0 1.6 6.5 1.8 7.0 7.5 2.0 Q [m³/h] Q [l/s] TM02 8933 1804 0 19 CHBasic General data CHBasic 2, CHBasic 3, CHBasic 4 6 3 Gr7896 4 Applications Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. Constructional features Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz. 20 16 28 TM02 9065 3204 1 7 Material specification Pos. Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft Stainless steel AISI 303 X10 CrNiS 18 9 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket NBR CHBasic Technical data Technical data Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive, chemically neutral and close to the characteristics of water. Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum suction depth: 8 metres (800 kPa) Maximum operating pressure: CHBasic 2, CHBasic 3, CHBasic 4: Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. 6 bar (600 kPa) Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. 21 CHBasic Technical data CHBasic 2 0 2 4 6 8 10 12 8 10 14 16 18 Q [US GPM] A C 0 2 4 6 12 14 16 Q [IMP GPM] H [ft] 160 P [kPa] H [m] 50 400 40 300 30 100 25 80 H2 H H1 DNA 45 TM02 9062 1704 G B 200 20 100 1x220-240 CHBasic 2 3x220-240/380-415 P2 P2 0 Capacitor [hp] [A] [µF] [Vc] 0.72 0.45 0.6 3.2 0.7 0 0.0 0.0 In [kW] 20 5 0.45 0.6 2.2/1.3 0.5 1.0 0.2 0 10 450 - - 10 1.5 0.4 20 2.0 2.5 3.0 0.6 0.8 30 40 3.5 4.0 Q [m³/h] 1.0 1.2 Q [l/s] 50 60 70Q [l/min] Packing dimensions [mm] Dimensions [mm] Pump type CHBasic 2 P1 Max. [kW] 40 10 Electrical data Voltage [V] 60 15 0 Pump type 120 35 IØ F E 140 A B C E F G Iø H H1 H2 DNA DNM L/A L/B L/H 406 175 122 207 13.5 111 9 200 179 143.5 Rp 1 Rp 1 480 212 265 TM02 9009 1304 DNM Vol [m3] Weight [kg] 0.027 12.5 CHBasic 3 0 2 4 6 8 10 12 8 10 14 16 18 20 22 24 Q [US GPM] A DNM H2 G B 500 50 400 40 300 TM02 9062 1704 IØ F E H 0 [m] 55 CHBasic 3 Pump type CHBasic 3 22 P2 P2 6 12 14 16 18 20 Q [IMP GPM] H [ft] 160 140 120 30 100 25 80 200 20 100 10 60 15 40 20 5 0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s] Electrical data P1 Max. [kW] [kW] [hp] 1x220-240 1.2 0.75 1 5.3 20 450 3x220-240/380-415 1.2 0.75 1 3.8/2.2 - - Voltage [V] 4 35 0 Pump type 2 45 H H1 DNA P [kPa] In Capacitor [A] [µF] [Vc] 0 10 20 30 40 50 60 70 80 Packing dimensions [mm] Dimensions [mm] A B C E F G Iø H H1 H2 DNA DNM L/A L/B L/H 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 90 Q [l/min] TM02 9010 1304 C Vol [m3] Weight [kg] 0.027 15.4 CHBasic Technical data CHBasic 4 0 4 8 12 16 20 24 28 32 Q [US GPM] A C 0 4 8 12 16 20 24 28 Q [IMP GPM] H [ft] 160 P [kPa] H [m] 50 400 40 300 30 100 25 80 H2 H H1 DNA 45 TM02 9062 1704 G B 200 20 100 CHBasic 4 P1 Max. [kW] P2 20 5 0 0 0 0.0 P2 In Capacitor [kW] [hp] [A] [µF] [Vc] 5.3 1x220-240 1.2 0.8 1.1 3x220-240/380-415 1.2 0.8 1.1 3.8/2.2 0 20 450 - - 1 2 3 0.8 0.4 20 40 4 5 1.2 60 80 6 1.6 7 2.0 100 Packing dimensions [mm] Dimensions [mm] Pump type CHBasic 4 40 10 Electrical data Voltage [V] 60 15 0 Pump type 120 35 IØ F E 140 A A1 B C E F G H H3 I DNA DNM L/A L/B L/H 425 175 122 207 13.5 111 9 213 179 143.5 Rp 1 Rp 1 480 212 265 Q [m³/h] Q [l/s] 120 Q [l/min] TM02 9011 1304 DNM Vol [m3] Weight [kg] 0.027 15.4 23 CHBasic PT General data CHBasic PT 6 3 Applications The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets. Constructional features Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. IP 44 IP 55 F 1 x 220-240 V, 50 Hz. Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top 24 16 28 7 Material specification Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. Motor protection: Terminal box protection: Insulation class: Standard voltage: 4 TM02 9065 3204 TM02 9061 1704 1 Pos. Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket NBR CHBasic PT Technical data Technical data Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum suction depth: 8 metres (800 kPa) Maximum operating pressure: CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa) Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. CHBasic 2 PT A1 D 0 500 H 0 [m] 55 8 12 4 8 16 20 12 24 16 28 20 32 24 Q [US GPM] 28 Q [IMP GPM] H [ft] 50 160 45 A 300 TM02 9066 1704 H 400 B CHBasic 2 PT CHBasic 3 PT 1 x 220-240 CHBasic 4 PT 120 30 100 25 80 20 100 10 60 15 40 20 5 CHBasic 2 P1 P2 P2 In Max. [kW] Capacitor [kW] [hp] [A] [µF] [Vc] 0.72 0.45 0.60 3.2 12.5 450 1.2 0.75 1.0 5.3 12.5 450 1.2 0.80 1.1 5.3 16 450 CHBasic 4 0 0 1 2 3 0.8 0.4 20 40 4 5 1.2 60 6 1.6 80 100 Packing dimensions [mm] Dimensions [mm] Pump type CHBasic 3 0 0 0.0 Electrical data Voltage [V] 35 200 0 Pump type 140 40 7 2.0 Q [m³/h] Q [l/s] TM02 8939 1704 H1 P [kPa] 4 120 Q [l/min] Vol [m3] Weight [kg] A A1 B D H H1 L DNA DNM L/A L/B L/H CHBasic 2 PT 550 405 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 17.7 CHBasic 3 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6 CHBasic 4 PT 550 425 270 281 290 200 330 Rp 1 Rp 1 576 366 554 0.107 20.6 25 CHBasic PS General data CHBasic PS 6 3 Gr7918 4 Applications Constructional features Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. 26 7 Material specification Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. Motor protection: Terminal box protection: Insulation class: Standard voltage: 16 28 TM02 9065 3204 1 IP 44 IP 55 F 1 x 220-240 V, 50 Hz. Pos. Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket NBR CHBasic PS Technical data Technical data Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum suction depth: 8 metres (800 kPa) Maximum operating pressure: CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa) Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. CHBasic PS 0 4 8 12 16 20 24 28 32 Q [US GPM] A D DNM DNM H 0 [m] 55 P [kPa] 500 4 8 12 16 20 24 28 Q [IMP GPM] H [ft] 50 160 E H2 Iø F TM02 9064 1704 H1 H3 DNA H 45 G B 40 35 120 300 30 100 25 80 200 20 100 CHBasic 2 PS CHBasic 3 PS 1 x 220-240 CHBasic 4 PS 40 10 20 5 CHBasic 2 P2 P2 In Max. [kW] [kW] [hp] [A] 1 2 3 0.8 0.4 4 5 1.2 6 1.6 7 2.0 Q [m³/h] Q [l/s] Capacitor [µF] [Vc] 1.75 0.45 0.60 3.2 10 450 1.20 0.75 1.00 5.3 20 450 1.20 0.80 1.10 5.3 20 450 0 20 40 60 80 100 Packing dimensions [mm] Dimensions [mm] Pump type CHBasic 4 0 0 0.0 P1 CHBasic 3 0 Electrical data Voltage [V] 60 15 0 Pump type 140 400 TM02 8939 1704 C 120 Q [l/min] Vol [m3] Weight [kg] A B C D E F G H H1 H2 H3 I DNA DNM L/A L/B L/H CHBasic 2 PS 405 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 14 CHBasic 3 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.031 17 CHBasic 4 PS 425 281 122 196 205 14 111 238 205 200 144 9 Rp 1 Rp 1 449 309 244 0.03 17 27 CHBasic PC General data CHBasic PC the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up. Gr7916 3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from being subjected to repeated starts caused by users opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is guaranteed by timing the stops. Applications Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. Operation The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations. Optimised management of the hydraulic installation and its components 1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up. 2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is opened the depression created in the system acts on 28 4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn. 5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds. 6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect. 7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off. 8. In the event of a power cut, automatic reset as soon as the power is restored. 9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out automatically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system. Constructional features Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in AISI 304 steel. Mechanical seal in carbon/ceramic. Rotor shaft in AISI 304 steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz. CHBasic PC 6 Technical data 3 4 16 28 TM02 9065 3204 1 7 Material specification Pos. Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 6 Diffuser Noryl GFN 2 7 Shaft AISI 303 stainless steel X 10 Cr NiS 18 9 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket NBR 29 CHBasic PC Technical data Technical data Operating range: From 0.6 to 10.5 m3/h with head up to 63 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non aggressive Liquid temperature range: From 0°C to +35°C for domestic use (Safety regulations EN 60335-2-41) From 0°C to +40°C for other uses. Maximum ambient temperature: +40°C Maximum suction depth: 8 metres (800 kPa) Maximum operating pressure: CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa) Installation: Fixed in a horizontal position Special executions on request: Other voltages and/or frequencies. Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. CHBasic PC C DMN 0 E B A 300 TM02 9063 1704 Iø G F 8 20 12 24 16 28 20 32 24 Q [US GPM] 28 Q [IMP GPM] H [ft] 160 Voltage [V] CHBasic 2 PC 1 x 220-240 CHBasic 4 PC 140 40 35 120 30 100 25 80 20 100 10 60 15 40 20 5 CHBasic 2 P1 P2 P2 In Max. [kW] [kW] [hp] [A] 0.72 0.45 0.6 1.2 0.75 1.0 1.2 0.80 1.1 Capacitor [Vc] 3.2 10 450 5.3 20 450 5.3 20 450 1 2 3 0.8 0.4 20 40 4 5 1.2 60 6 1.6 80 100 Packing dimensions [mm] Dimensions [mm] Pump type CHBasic 4 0 0 [µF] CHBasic 3 0 0 0.0 Electrical data 30 4 16 50 200 0 CHBasic 3 PC 12 45 400 Pump type H 0 [m] 55 8 7 2.0 Q [m³/h] Q [l/s] TM02 8939 1704 500 DNA H P [kPa] 4 120 Q [l/min] Vol [m3] Weight [kg] A B C E F G H Iø DNA DNM L/A L/B L/H CHBasic 2 PC 406 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 14 CHBasic 3 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16 CHBasic 4 PC 425 212 122 207 13.5 111 376 9 Rp 1 Rp 1 524 248 309 0.04 16 NSBasic NSBasic Single impeller Performance range p [kPa] 700 H [m] NSBasic 70 50 Hz 65 600 5-60 60 55 500 5-50 50 45 400 6-40 3-40 40 6-30 35 5-33 300 30 25 4-23 200 20 13-18 15 100 10 5 0 0 0.0 1 2 0.5 3 4 1.0 5 6 1.5 7 2.0 8 9 2.5 10 11 3.0 12 13 3.5 14 4.0 15 16 4.5 17 Q [m³/h] Q [l/s] TM02 8934 1804 0 31 NSBasic General data NSBasic single impeller pumps Gr7897 Applications Constructional features Pump Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. 32 16 7 Description IP 44 IP 55 for the single-phase version F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz. Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller Noryl GFN 2 7 Shaft Pump types X 12 CrNi 1810 NSBasic 4-23 - NSBasic 13-18 X 10 CrNi 1809 NSBasic 5-33 16 Mechanical seal Carbon/Ceramic 28 O-Ring Gasket Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Insulation class: Standard voltage: 3 Material specification Single impeller centrifugal pump designed for lifting water in domestic, civil, industrial and agricultural installations and for decanting, mixing and irrigating uses. Motor protection: Terminal box protection: 28 TM02 9070 1704 4 1 NBR NSBasic Technical data Technical data Operating range: From 1.8 to 16.8 m3/h with head up to 34 metres Liquid quality requirements: Clean, free from solids or abrasive substances, non viscous, non aggressive, noncrystallized, chemically neutral, close to the characteristics of water. Liquid temperature range: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: Maximum ambient temperature: +40°C Maximum operating pressure: NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: Installation: Fixed in a horizontal or vertical position, as long as the motor is above the pump Special versions on request: Other voltages and/or frequencies. from -10°C to + 50°C 6 bar (600 kPa) The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. NSBasic 4-23 0 4 0 4 12 16 8 12 20 16 24 Q [US GPM] 20 Q [IMP GPM] H [ft] H [m] 20 TM02 9089 1804Single impeller 160 80 60 15 40 10 20 5 0 P2 [hp] 0.4 0.2 0.0 0 P2 [kW] 0.4 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h] P2 0.2 20 Eta 0.0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s] Electrical data Pump type NSBasic 4-23 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] In Capacitor [A] [µF] [Vc] 0.65 3.0 0.37 NSBasic 4-23 3x220-240/380-415 0.64 0.37 Pump type NSBasic 4-23 0.5 0.5 2.3/1.3 10 450 - - 0 Dimensions [mm] A B C D E F G I H H1 H2 275 160 50 100 50 15 110 9 205 85 120 Eta [%] 40 DNA DNM Rp 1 Rp 1 10 20 30 40 50 60 70 80 Packing dimensions [mm] 90 Q [l/min] TM02 9012 1304 P [kPa] 8 L/A L/B L/H Vol [m3] Weight [kg] 362 222 262 0.021 10.3 33 NSBasic Technical data NSBasic 5-33 0 4 0 P [kPa] 320 8 4 12 16 8 20 12 24 16 28 20 32 24 36 28 Q [US GPM] H [m] 32 Q [IMP GPM] H [ft] 30 100 240 TM02 9089 1804 160 80 20 80 10 0 0 P2 [hp] 0.8 0.4 0.0 60 40 20 0 P2 [kW] 0.8 0 1 2 3 4 5 6 7 8 Q [m³/h] P2 0.4 Eta [%] 40 20 Eta 0.0 0 0.0 0 1 2 3 0.8 0.4 4 5 1.2 6 1.6 7 2.0 8 Q [m³/h] 2.4 Q [l/s] Pump type NSBasic 5-33 P1 P2 P2 Max. [kW] [kW] [hp] Voltage [V] 1x220-240 NSBasic 5-33 3x220-240/380-415 Pump type NSBasic 5-33 In Capacitor [A] [µF] [Vc] 1.3 0.75 1 6.0 20 450 1.2 0.75 1 4.3/2.5 - - 0 Dimensions [mm] DNA A B C D E F G I H H1 H2 300 185 50 108 58 15 140 9 235 100 135 20 40 80 100 120 Packing dimensions [mm] DNM Rp 1 60 Rp 1 L/A L/B L/H 392 232 262 TM02 9013 1304 Electrical data Q [l/min] Vol [m3] Weight [kg] 0.024 14.7 NSBasic 13-18 0 0 5 10 15 20 25 30 35 40 45 50 55 60 H [m] Q [US GPM] Q [IMP GPM] H [ft] 20 160 80 60 15 40 10 20 5 TM02 9089 1804 0 P2 [hp] 0.8 0.4 0.0 0 P2 [kW] 0.8 0 0 2 4 6 8 10 12 14 16 Q [m³/h] P2 0.4 Eta [%] 40 20 Eta 0.0 0 0.0 2 0.5 0 4 1.0 6 1.5 8 2.0 10 12 14 2.5 3.0 3.5 4.0 16 4.5 Q [m³/h] Q [l/s] TM02 9014 1304 P [kPa] 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Electrical data Pump type NSBasic 13-18 Voltage [V] P1 P2 P2 Max. [kW] [kW] [hp] 1x220-240 NSBasic 13-18 3x220-240/380-415 Pump type NSBasic 13-18 34 In Capacitor [A] [µF] [Vc] 1.1 0.75 1 4.6 20 450 1.1 0.75 1 3.6/2.1 - - 0 Dimensions [mm] A B C D E F G I H H1 H2 312 169 45 114 69 15 110 9 210 210 125 40 DNA DNM Rp 1½ Rp 1½ 80 120 160 200 240 Packing dimensions [mm] L/A L/B L/H 392 232 262 Q [l/min] Vol [m 3] Weight [kg] 0.024 14 NSBasic General data NSBasic twin impeller pumps 1 4 28 3 16 TM02 9069 1704 Gr7928 34 7 Material specification Applications Muliti-stage centrifugal pump with opposed twin impellers. Designed for use in pressurisation units for water supply systems and for supplying pressurised tanks. Suitable also for sprinkling, irrigation and other water supply application. Constructional features Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Description Material 1 Pump body Cast iron EN-GJL-200 3 Support Cast iron EN-GJL-200 4 Impeller 7 Shaft Pump types Noryl GFN 2 NSBasic 3-40 - NSBasic 5-50 NSBasic 6-30 - NSBasic 6-40 Ultem 2300 NSBasic 5-60 Stainless steel ANSI X12 CrNi 1810 16 Mechanical seal Carbon/Ceramic 28 O-ring gasket Impregnated Cellulose 34 Intermediate Disc Cast iron EN-GJL-200 Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 for the single-phase version up to and including 0.75 kW F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz. 35 NSBasic Technical data Technical data Operating range: From 1.5 to 10.8 m3/h with head up to 60 metres. Liquid quality requirements: clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. Liquid temperature range: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from –10°C to + 50°C NSBasic 5-60: from –15°C to + 110°C Maximum ambient temperature: +40°C Maximum operating pressure: NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa) NSBasic 5-50, NSBasic 5-60: 8 bar ( 800 kPa) Installation: Fixed in a horizontal or vertical position, as long as the motor is above the pump. Special versions on request: Other voltages and/or frequencies. The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. NSBasic 3-40 0 4 TM02 9088 1804Twin impeller 0 P [kPa] 400 H [m] 300 30 200 20 100 10 0 0 P2 [hp] 0.8 0.4 0.0 8 4 12 16 8 12 20 16 24 Q [US GPM] 20 Q [IMP GPM] H [ft] 40 P2 [kW] 0.8 120 80 40 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h] P2 0.4 Eta [%] 40 20 Eta 0.0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s] Voltage [V] NSBasic 3-40 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] NSBasic 3-40 3x220-240/380-415 Pump type NSBasic 3-40 36 In Capacitor [A] [µF] [Vc] 1.2 0.75 1 5.5 20 450 1.2 0.75 1 3.8/2.2 - - 0 Dimensions [mm] DNA A B C D E F G I H H1 H2 342 180 76 148 72 15 148 9.5 235 100 135 Rp 1 10 DNM Rp 1 20 30 40 50 60 70 80 Packing dimensions [mm] L/A L/B L/H 392 232 262 90 TM02 9015 1304 Electrical data Pump type Q [l/min] Vol [m3] Weight [kg] 0.024 16.1 NSBasic Technical data NSBasic 5-50 0 4 0 H [m] 50 400 40 300 30 200 20 100 10 0 0 TM002 9088 1804 P [kPa] P2 [hp] 8 12 4 16 8 20 12 24 16 28 20 32 24 Q [US GPM] 28 Q [IMP GPM] H [ft] 160 120 80 40 0 0 P2 [kW] 1.6 1 2 3 4 5 6 7 Q [m³/h] Eta [%] 40 P2 1.6 0.8 0.0 0.8 20 Eta 0.0 0 0 1 2 3 4 0.0 0.2 0.4 0.6 0.8 1.0 1.2 5 1.4 6 7 1.6 1.8 2.0 Q [m³/h] 2.2 Q [l/s] NSBasic 5-50 P1 P2 P2 Max. [kW] [kW] [hp] Voltage [V] 1x220-240 NSBasic 5-50 3x220-240/380-415 Pump type In Capacitor [A] [µF] [Vc] 8.3 31.5 450 1.9 1.1 1.5 2.0 1.1 1.5 6.0/3.5 - 0 10 20 30 40 50 60 70 80 90 100 110 120 Q [l/min] - Dimensions [mm] Phase TM02 9016 1304 Electrical data Pump type DNA A B C D E F G I H H1 H2 Packing dimensions [mm] DNM L/A L/B L/H Vol [m3] Weight [kg] NSBasic 5-50 1 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 235 295 0.029 23.3 NSBasic 5-50 3 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ Rp 1 415 234 295 0.029 23.8 NSBasic 5-60 0 4 0 8 4 12 8 16 20 12 24 16 28 20 32 24 36 28 40 32 Q [US GPM] P [kPa] H [m] Q [IMP GPM] H [ft] 600 60 200 400 40 200 20 0 0 P2 [hp] 2 1 0 120 80 40 0 0 P2 [kW] 2 1 2 3 4 5 6 7 8 9 Q [m³/h] P2 1 Eta [%] 40 20 Eta 0 0 0 0.0 1 2 3 0.8 0.4 4 5 1.2 6 1.6 7 2.0 8 9 2.4 Q [m³/h] Q [l/s] TM02 9017 1304 TM02 9088 1804 160 Electrical data Pump type NSBasic 5-60 P1 P2 P2 Max. [kW] [kW] [hp] Voltage [V] 1x220-240 NSBasic 5-60 3x220-240/380-415 Pump type NSBasic 5-60 In Capacitor [A] [µF] [Vc] 2.7 1.8 2.5 12.8 2.5 1.8 2.5 8.4/4.8 40 450 - - 0 Dimensions [mm] DNA A B C D E F G I H H1 H2 370 210 75 144 69 15 165 11.5 268 118 150 Rp 1¼ 20 DNM Rp 1 40 60 80 100 120 Packing dimensions [mm] L/A L/B L/H 415 234 295 140 Q [l/min] Vol [m3] Weight [kg] 0.032 23.8 37 NSBasic Technical data NSBasic 6-30 0 TM02 9090 1804 0 P [kPa] 400 H [m] 300 30 200 20 100 10 0 0 P2 [hp] 4 8 4 12 8 16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40 Q [US GPM] Q [IMP GPM] H [ft] 40 P2 [kW] 1.6 1.6 0.8 0.0 120 80 40 0 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] P2 0.8 Eta [%] 40 20 Eta 0.0 0 0 0.0 1 2 3 0.8 0.4 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m³/h] 2.8 Q [l/s] Pump type NSBasic 6-30 P1 P2 P2 Max. [kW] [kW] [hp] Voltage [V] 1x220-240V In Capacitor [A] [µF] [Vc] 1.56 1.1 1.5 7.1 25 450 3x220-240/380-415 1.56 1.1 1.5 5.4/3.1 - - Pump type NSBasic 6-30 0 Dimensions [mm] DNA A B C E F G I H H1 387 205 88 179 20 145 11 233 108 20 40 60 100 120 140 160 180Q [l/min] Packing dimensions [mm] DNM Rp 1½ 80 Rp 1 L/A L/B L/H 415 234 295 TM02 9018 1304 Electrical data Vol [m3] Weight [kg] 0.028 21.5 NSBasic 6-40 0 0 P [kPa] 400 H [m] 300 30 200 20 100 10 TM02 9090 1804 8 4 12 8 16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40 Q [US GPM] Q [IMP GPM] H [ft] 40 0 P2 [hp] 4 120 80 40 0 P2 [kW] 1.6 1.6 0.8 0.0 0 0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h] P2 0.8 Eta [%] 40 20 Eta 0.0 0 0 0.0 1 2 0.4 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m³/h] 2.8 Q [l/s] Pump type NSBasic 6-40 Voltage [V] P1 P2 P2 Max. [kW] [kW] [hp] 38 Capacitor [A] [µF] [Vc] 1x220-240V 2 1.85 2.5 9 40 450 3x220-240/ 380-415 2.0 1.85 2.5 6.2/3.6 - - 0 Dimensions [mm] Pump type NSBasic 6-40 In 20 DNA DNM 40 60 80 100 120 140 Packing dimensions [mm] L/H 160 TM02 9019 1304 Electrical data 180Q [l/min] Vol [m3] Weight [kg] A B C E F G I H H1 L/A L/B 461 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 510 234 285 0.034 25.9 387 205 88 179 20 145 11 233 108 Rp 1½ Rp 1 415 234 295 0.028 22 KPBasic KPBasic Performance range p [kPa] H [m] KPBasic 10.5 100 10.0 50 Hz 600 (A) 9.5 90 9.0 8.5 80 8.0 7.5 70 7.0 300 A 6.5 60 6.0 200 5.5 50 5.0 4.5 40 4.0 3.5 30 3.0 2.5 20 2.0 1.5 10 1.0 0.5 0.0 0 0.0 1 2 0.5 3 4 1.0 5 6 1.5 7 2.0 8 9 2.5 10 11 3.0 12 13 3.5 14 4.0 15 16 4.5 17 Q [m³/h] Q [l/s] TM02 8937 1804 0 39 KPBasic General data KPBasic KPBasic 200: Supplied standard with 10 metres of H05 RN-F power cable. KPBasic 300 A: Supplied standard with 10 metres of H05 RN-F power cable. Note: 5 m cable om request. Supplied standard with 10 metres of H07 RN-F power cable. KPBasic 600: KPBasic 600 A: Supplied standard with 10 metres of H07 RN-F power cable. Note: 5m cable on request. Degree of protection: IP 68 Insulation class: F Gr7913 Manufactured according to standard EN 60335-2-41. Standard voltage: 1 x 220-240V, 50 Hz 3 x 380-415V, 50 Hz. Applications The submersible pump from the KPBasic series is designed mainly for automatically operated fixed applications in domestic use, draining basements and garages which are subject to flooding. Descriptions and materials Thanks to its compact, easy to handle design, it can also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general. The level switch allows fixed installation and guarantees automatic pump operation. Table of performance ranges and possible applications KPBasic DNM connections Rp 1¼ Flow rate Q [m3/h] Max. 16 Max. 10.8 o Temperature t [ C] 29 Max. +40 Rain water z Clean waste water z 1 78 Constructional features Pump Water-resistant technopolymer pump body, impeller, top body and suction grid. Stainless steel motor casing, rotor shaft and screws. Triple "O" ring seals interposed with oil chamber. 40 54 73 79 32 Pos. 4 Descriptions Materials 1 Pump body Noryl GFN 2 4 impeller Noryl GFN 2 Motor 29 O-ring gasket NBR Continous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a top body which encases cabling, microswitch and capacitor. Rotor mounted on oversized greased sealedfor-life ball bearings selected to guarantee silent running and long life. Built-in thermal and current overload protection and a capacitor which is permanently in circuit in the single-phase version. 32 Stop ring Stainless steel 12E Motor - Top body Stainless steel AISI 304 X5 CrNi 1810 - Shaft Stainless steel AISI 304 X5 CrNi 1810 78 Pressure disc Noryl GFN 2 79 Suction grid Noryl GFN 2 54 TM02 8468 3204 Head H [m] KPBasic Technical data Technical data Operation range: Liquid quality requirements: From 1 to 16 m3/h with head up to 10.2 metres Grey water without fibres Granulometric passage though the suction grid: KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A 5 mm 10 mm 10 mm 10 mm Minimum draught depth: KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A 8 mm 85 mm 38 mm 175 mm Liquid temperature range: Maximum immersion: Maximum dry running time: From 0°C to +35°C 7 metres 1 minute Automatic float switch: Type name extension: A Special versionson request: Other voltages and/or frequencies Installation: Fixed or portable in a vertical position. The minimum pit dimensions for fixed installation with automatic operation are indicated in the drawing. Curve conditions The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A. KPBasic 600 A Minimum dimension for the pit for KPBasic 300 A with automatic float switch Minimum dimension for the pit for KPBasic 600 A with automatic float switch 400 TM02 9101 1804 400 TM02 9100 1804 500 400 KPBasic 300 A 41 KPBasic Technical data 0 4 0 P [kPa] 80 8 4 KPBasic 300A 12 8 16 20 12 24 16 28 20 32 24 36 28 40 32 44 0 Q [US GPM] 36 0 Q [IMP GPM] H [ft] H [m] 4 P [kPa] 80 8 12 16 20 24 28 32 36 40 44 48 52 56 4 8 12 16 20 24 28 32 H [m] Q [US GPM] 36 40 44 48 Q [IMP GPM] H [ft] 8 25 8 25 60 6 20 60 6 20 40 4 15 40 4 20 2 0 0 10 20 2 5 0 0 0 0.2 0.1 0.0 P2 [kW] 0.2 0 1 2 3 4 5 6 7 8 9 10 Q [m³/h] P2 0.1 20 Eta 0.0 0 0.0 0 1 0 2 3 0.8 0.4 20 40 4 5 6 1.2 1.6 60 80 7 8 9 2.0 2.4 100 120 140 P2 [hp] Eta [%] 40 10 Q [m³/h] 2.8 Q [l/s] 160 Q [l/min] TM02 9020 1304 P2 [hp] 0.2 0.1 0.0 P2 [kW] 0.2 15 10 5 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h] P2 0.1 Eta [%] 40 20 Eta 0.0 0 0 1 2 3 0.0 0.4 0.8 0 20 40 4 5 6 1.2 1.6 60 7 8 9 2.0 2.4 10 11 12 Q [m³/h] 2.8 3.2 3.6 Q [l/s] 80 100 120 140 160 180 200 Q [l/min] TM02 9021 1304 KPBasic 200 Liv.max. Liv.min. H TM02 8466 0204 H2 H1 KPBasic 200, KPBasic 300A E B A D Electrical data Pump type P2 P2 In Capacitor Voltage [V] P1 Max. [W] [kW] [hp] [A] [µF] [Vc] KPBasic 200 1x220-240 350 0.22 0.3 1.5 8 450 KPBasic 300A 1x220-240 350 0.22 0.3 1.5 8 450 Liv. min. Liv. max. A B D E H H1 H2 [mm] [mm] KPBasic 200 185 140 225 82 266 390 38,5 100 350 KPBasic 300A 185 140 225 82 275 390 47,5 100 350 Pump type 42 Dimensions [mm] Packing dimensions [mm] L/A L/B L/H Vol [m3] Rp 1¼ 207 227 312 0.016 4.5 Rp 1¼ 207 227 312 0.016 4.6 DNM Weight [kg] KPBasic Technical data KPBasic 600 (A) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [IMP GPM] H [ft] 2 0 0 P2 0 [kW] 0.6 0.4 0.2 0.0 0 0.0 0 2 4 6 8 10 12 14 16 Q [m³/h] P2 Eta 2 0.5 4 1.0 40 6 1.5 80 8 2.0 2.5 120 10 12 14 3.0 3.5 4.0 160 200 16 4.5 240 Eta [%] 30 20 10 0 Q [m³/h] Q [l/s] Q [l/min] E TM02 8466 0204 4 20 H2 6 40 30 25 20 15 10 5 0 H1 8 Liv.max. 10 15 20 25 30 35 40 45 50 55 60 TM02 9022 1304 80 60 P2 [hp] 0.8 0.6 0.4 0.2 0.0 5 H [m] 10 Liv.min. 0 P [kPa] Q [US GPM] H 0 KPBasic 600 (A) B A D Electrical data Pump type Voltage [V] P1 Max. [W] P2 [kW] In Capacitor [hp] [A] [µF] [Vc] P2 KPBasic 600 1x220-240 800 0.55 0.75 3.4 14 450 KPBasic 600A 1x220-240 800 0.55 0.75 3.4 14 450 KPBasic 600 3x380-415 800 0.55 0.75 3.4 - - Liv. min. Liv. max. A B D E H H1 H2 [mm] [mm] KPBasic 600 200 160 225 90 376 490 73 200 450 KPBasic 600A 200 160 225 90 376 490 73 200 450 Pump type Dimensions [mm] Packing dimensions [mm] L/A L/B L/H Vol [m3] Rp 1 ¼ 207 227 422 0.021 7 Rp 1 ¼ 207 227 422 0.021 6.7 DNM Weight [kg] 43 PFBasic PFBasic Performance range p [kPa] 600 H [m] 55 500 PF(P)Basic 50 Hz 60 PFPBasic 2-50 50 PFBasic 2-50 45 400 40 35 300 PFBasic 1-30 30 25 200 20 15 100 10 5 0 0.0 0.0 44 0.2 0.4 0.1 0.6 0.8 0.2 1.0 0.3 1.2 1.4 0.4 1.6 1.8 0.5 2.0 2.2 0.6 2.4 2.6 0.7 2.8 Q [m³/h] 0.8 Q [l/s] TM02 8935 1804 0 PFBasic General data PFBasic 1 28 Applications 16 TM02 9071 1704 GR7901 4 7 Material specification Peripheral centrifugal pump with compact dimensions. Able to generate high heads and suitable for domestic installations, water supply systems, light gardening applications, draining and filling cisterns, as well as light industrial uses such as feeding pressurized boilers (anticondensation). Pos. Description Material 1 Pump body Cast iron EN-GJL-200 4 Impeller Brass PCu Zn 40 Pb2 5705-65 7 Shaft Stainless steel AISI 416 X12 CrS 13 16 Mechanical seal Carbon/ceramic 28 O-ring gasket NBR rubber Constructional features Pump Cast iron pump body and motor support with brass wear disc. Brass impeller. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings to ensure silent running and long life. The motor incorporates a built-in thermal and current overload protection as well as a capacitor, switched on permanently. Manufactured according to standard EN 60335-2-41. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: Single-phase 220-240 V, 50 Hz. Other voltages and frequencies are available on request. 45 PFBasic Technical data Technical data Operating range: From 0.3 to 2.7 m3/h with heads up to 53 metres. Pumped liquid: Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41) From –10°C to +50°C for other uses. Maximum ambient temperature: +40°C Maximum operating pressure: - PFBasic 1-30: 6 bar (600 kPa) - PFBasic 2-50: 10 bar (1000 kPa) Installation: Fixed in the horizontal position. The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A. p [kPa] H [m] 56 480 48 400 40 PFBasic 2-50 52 50 Hz ISO 9906 Annex A 44 36 320 1-30 32 28 240 24 20 160 16 12 80 8 0 0 4 0.4 0.0 0.8 1.2 0.2 1.6 2.0 0.4 2.4 Q [m³/h] 0.6 TM02 6757 1304 TM02 9091 1804 0.0 Q [l/s] Electrical data Capacitor Model Voltage [V] P1 max. [kW] P2 [kW] P2 [hp] In [A] [µF] [Vc] PFBasic 1-30 1 x 220-240 0.47 0.3 0.4 2 8 450 PFBasic 2-50 1 x 220-240 0.86 0.6 0.8 3.8 12.5 450 Dimensions and weights Model 46 A B B1 C E F G I H H1 H2 DNA DNM Packing dimensions [mm] L/A L/B L/H Volume [m 3] Weight [kg] PFBasic 1-30 228 132 165 22 46 - 65 8 158 103 138 Rp 1 Rp 1 259 164 197 0.008 5.3 PFBasic 2-50 255 130 - 26 106 80 100 7 186 108 153 Rp 1 Rp 1 271 176 209 0.01 7.5 PFPBasic General data PFPBasic 2-50 Applications 3 28 4 7 TM02 9072 1704 Gr7900General data 1 16 Materials Self-priming pump with side liquid channel and starshaped impeller, with excellent suction capacities even in unfavourable operating conditions such as the presence of air bubbles or lack of continuity in the sucked liquid. Used in domestic, agricultural civil and industrial installations. Constructional features Pump Pos. Description Material 1 Pump body Cast iron EN-GJL-200, with brass wear ring PCuZn 40 Pb2 5705/65 3 Motor support Brass PCu Zn 40 Pb2 5705/65 4 Impeller Brass PCu Zn 40 Pb2 5705/65 7 Shaft Stainless steel AISI 416 X12 CrS 13 16 Mechanical seal Carbon/ceramic 28 O-ring gasket FKM Cast iron pump body with brass pressure disc. Motor support and impeller completely made of brass, to avoid the risk of blockage. Carbon/ceramic mechanical seal. Stainless steel motor shaft. Motor Asynchronous motor, cooled by external fan. Rotor mounted on oversized, greased and sealed-for-life ball bearings to ensure quiet operation and long life. The single-phase version has built-in thermal and current overload protection. Manufactured according to standard EN60335-2-41. Motor protection: IP 44 IP 55 terminal board protection Insulation class: F Standard voltage: Single-phase 220-240 V, 50 Hz. Other voltages and frequencies are available on request. 47 PFPBasic Technical data Operating conditions Operating range: From 0.5 to 2.7 m3/h with heads up to 53 metres. Pumped liquid: Clean, free from solids or abrasive substances, non-aggressive, noncrystallized, chemically neutral, similar to the characteristics of water. Liquid temperature range: From –10°C to +80°C Maximum ambient temperature: +40°C Maximum operating pressure: 10 bar (1000 kPa) Installation: Fixed in the horizontal position. The performance curves are based on a kinematic viscosity value of 1 mm²/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A. p [kPa] H [m] 56 PFPBasic 2-50 52 50 Hz 480 48 ISO 9906 Annex A 400 40 44 36 320 32 28 240 24 20 160 16 12 80 8 0 0 TM02 9092 1804 0.0 0.4 0.8 0.0 1.2 0.2 1.6 0.4 2.0 0.6 2.4 2.8 Q [m³/h] 0.8 Q [l/s] TM02 6758 1304 4 Electrical data PFPBasic 2-50 Capacitor Voltage [V] P1 max. [kW] P2 [kW] P2 [hp] In [A] µF Vc 1 x 220-240 1.05 0.75 1 4.7 20 450 Model Dimensions and weights Model PFPBasic 2-50 48 A B C E F G I H H1 H2 DNA DNM 301 142 38 136 90 112 7 206 146 187 Rp 1 Rp 1 Packing dimensions [mm] L/A L/B L/H Volume [m3] Weight [kg] 406 267 402 0.044 10.7 49 50 51 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96548246 0804 - c1 GB Subject to alterations. GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00. www.grundfos.com