Assembly Roxy
Transcription
Assembly Roxy
Assembly Roxy - Central Capacity: 250 2 Roxburgh Place, EH8 9SU Schedule C Roxy Central Outline description of the stage and technical facilities provided by Assembly. 1. SEATING 2. THE STAGE 3. MASKING 4. SUSPENSION 5. LIGHTING Roxy Central is an end on theatre with a raked auditorium with 252. The performance area is 8.0m wide x 7m depth, narrowing to 5.8m wide at around 4m depth. It is constructed of stagedex and covered in black dance floor. The stage is at 535mm high. Access to the stage is from stage rights or stage left. It is not permissible to screw into the venue floor or walls. Black box,no wing area, limited Crossover. Clearance height below the upstage truss grid is approx 5.5m. A truss grid above the stage supports a number of fixed lighting bars. There are no flying facilities. It may be possible to hang lightweight items of scenery from the grid on single lines at the discretion of the Technical Manager. The lighting control position is located at the rear of the auditorium, it is not possible for one person to operate both lighting and sound. Equipment CONTROL: ETC ION DIMMERS: 48 x 10Amp POWER SUPPLY MAXIMUM LOAD: 40 kW FIXED RIG MOVING LIGHTS: - 2 x Martin Mac 700 Profile (available for hire) - 4 x Martin Mac Aura Wash (available for hire) A good general cover of warm and cool light over the performance area is provided. The position and focus of these lanterns may not be changed, however they may be coloured for your show, provided this is possible within your set-up and strike time. Additional lanterns can be rigged as company specials but must come from the stock of Assembly Theatre’s supplier. These units will be charged as an additional cost. Moving lights as listed above in the fixed rig are available for hire. Blackout on stage is acceptable; however, absolute blackout is not possible due to emergency lighting regulations. Roxy Central June 14 We do not allow companies to bring their own lights. For the most up to date plans and technical specifications, please liaise with the Head of Lighting in the lead up to the festival. Please note these specifications are subject to change. 6. SOUND The control position is located at the rear of the auditorium, it is not possible for one person to operate both lighting and sound. We do not allow companies to bring their own sound equipment. System : L-Acoustics L&R Line array system with front fills – plans available on request. Monitors: 4 x Floor monitors available FOH Desk: Yamaha CL3 48 Input Digital Console with on board processing and effects FOH Playback 1: 1 x Dedicated computer with sound replay/cue software FOH Playback 2: 1 x 3.5mm Jack inputs The basic rig also includes 4 wired dynamic SM58 microphones and 4 DI boxes. For information and costs for radio microphones please contact the Head of Sound. Additional microphones, other sound equipment and backline equipment is available for hire. This equipment is provided by Assembly Theatre’s supplier and will be charged as an additional cost – details on request. All sound equipment must be agreed in advance with the Head of Sound or the Technical Manager. 7. DRESSING ROOM 8. STORAGE 9. ACCESS This is shared by all companies performing in the venue and is located to the rear of the venue. Tables, chairs and mirrors are provided for communal use. The management cannot accept responsibility for the security of any items left in the dressing room. You will have access to the storage and dressing room 40 minutes before and for 20 minutes after your performance each day. Backstage storage is extremely limited and we recommend that companies keep their scenery/props requirements to an absolute minimum. Small items of scenery and props may be stored in the dressing room at the discretion of the Technical Manager. It is worth ensuring that your set is light yet durable enough to withstand daily dismantling. ALL SET ITEMS ARE REQUIRED TO EASILY PASS THROUGH A STANDARD DOOR. The access to central is an arched doorway 1.1m wide x 2.1m high. Roxy Central is accessible from: 2 Roxburgh Place Edinburgh EH8 9SU Load in and access is through a standard double door. Please check before attempting to bring large pieces of scenery - they may not fit through the doors. Roxy Central June 14 10. STAFF 11. NOTES The theatre personnel work on a rota basis, the duty rota comprises one stage manager, one lighting technician and one sound technician. If the visiting manager requires additional staff to assist with the turn around, or the use of casual crew during the load in or load out, then this can be organised at additional cost. If the venue technical staff are required to participate for anything more than lights up /lights down (one cue to bring the house to a performance state and mic live and then one cue to bring the house back to exit state) during the performance, the Visiting Company will be liable for a show call charge for each technician used. The rate is £25 per performance per technician plus VAT. Any additional staff or items of equipment, which the management are requested to provide, will be charged to the visiting company. Any practical electrical equipment you wish to use should have a current PAT certificate and be cleared with us. We reserve the right to refuse the use of any equipment which is deemed unsafe. Each company is assigned a get in/rehearsal time prior to their first performance This is the time for you to load your set and props into the venue and for you to re-tech your show. You will also need to allow sufficient time to rehearse your daily turnaround and set storage. Please note that your slot time must include get-in and get-out time. Please note that, due to the Scottish Executive regulations, smoking is not permitted in any venues. At the end of the festival, please arrange for removal or disposal of your set and any unused publicity material. There will be a charge applied to cover the cost of disposal should you not comply with this request. Please note, since this is a temporary conversion and not a permanent theatre, all measurement and quantities quoted in the above specification are approximate and may be subject to change. For detailed and up to date information regarding the venue please contact the Technical Manager – [email protected]. Roxy Central June 14 assembly 2013 Roxy Central Initial Plans SUBJECT TO CHANGE 11/4/13 Note: 8110 Set store sound & LX control 698 5867 8000 Store [email protected] assembly 2013 Roxy Central Initial Plans - Iso and elevation SUBJECT TO CHANGE 11/4/13 Note: 6112 5644 5959 535 [email protected] 1 2 3 4 5 6 7 A A 44 34 L075 L134 45 35 L075 L134 303 46 36 L075 L134 304 B B 41 31 42 32 43 33 L075 L134 L075 L134 L075 L134 drawing no revision sheet size ROXYCLXFR14 1 A3 legend X2 Instruments X2 Used C C MAC 700 Profile 2 S4 Zoom 25° - 50º 9 1.2kw Fresnel 18 Par 64 (CP 62) 4 House Light & Working Light 5 Aisle Lights 4 Shelley 2003 54 4 ©Steve 302 64MFL 301 64MFL 53 MAC Aura 700 PRO 25°-50° 64MFL 64MFL 64MFL 51 52 D D Legend X3 L201 24 14 25 15 26 16 2003 L013 Shelley L201 ©Steve L013 X1 Gobo 1 L013 Position L201 Color EXIT EXIT X3 Channel Purpose E E notes LIGHTING CONTROL: ETC ION DIMMERS: 48 Channels (31 used in fixed rig) FIXED RIG MOVING LIGHTS Available for Hire: 4 x Mac Aura (LED Wash) 2 x Mac 700 Profile Spots L201 25°-50° 25°-50° X1 L013 L201 L013 25°-50° 25°-50° 25°-50° 23 13 21 11 Shelley ©Steve Shelley ©Steve F Dimmable House Lighting 2003 L013 25°-50° 2003 L201 700 700 PRO PRO 701 22 12 702 F NOTE: Lighting fixtures & plan are subject to change. For most up to date plan, please contact Assembly Head of Lighting. information client Assembly Festival project Edinburgh Fringe Festival 2014 venue R119 R119 R119 25°-50° 25°-50° 25°-50° title designer X1 X3 X3 drawn 2 1 G 3 Roxy Central Lighting Fixed Rig AL scale 1:50 date 09-06-2014 Assembly Festival 2 Roxburgh Place Edinburgh EH8 9SU T. +44 (0) 131 623 3000 http://www.assemblyfestival.com 1 2 3 4 5 6 7 G