Assembly Roxy

Transcription

Assembly Roxy
Assembly Roxy - Central
Capacity: 250
2 Roxburgh Place, EH8 9SU
Schedule C
Roxy Central
Outline description of the stage and technical facilities provided by Assembly.
1.
SEATING
2.
THE STAGE
3.
MASKING
4.
SUSPENSION
5.
LIGHTING
Roxy Central is an end on theatre with a raked auditorium with 252.
The performance area is 8.0m wide x 7m depth, narrowing to 5.8m wide at around 4m depth.
It is constructed of stagedex and covered in black dance floor.
The stage is at 535mm high.
Access to the stage is from stage rights or stage left.
It is not permissible to screw into the venue floor or walls.
Black box,no wing area, limited Crossover.
Clearance height below the upstage truss grid is approx 5.5m.
A truss grid above the stage supports a number of fixed lighting bars.
There are no flying facilities.
It may be possible to hang lightweight items of scenery from the grid on single lines at the
discretion of the Technical Manager.
The lighting control position is located at the rear of the auditorium, it is not possible for one
person to operate both lighting and sound.
Equipment
CONTROL: ETC ION
DIMMERS: 48 x 10Amp
POWER SUPPLY MAXIMUM LOAD: 40 kW
FIXED RIG MOVING LIGHTS:
- 2 x Martin Mac 700 Profile (available for hire)
- 4 x Martin Mac Aura Wash (available for hire)
A good general cover of warm and cool light over the performance area is provided. The
position and focus of these lanterns may not be changed, however they may be coloured for
your show, provided this is possible within your set-up and strike time.
Additional lanterns can be rigged as company specials but must come from the stock of
Assembly Theatre’s supplier. These units will be charged as an additional cost.
Moving lights as listed above in the fixed rig are available for hire.
Blackout on stage is acceptable; however, absolute blackout is not possible due to emergency
lighting regulations.
Roxy Central
June 14
We do not allow companies to bring their own lights.
For the most up to date plans and technical specifications, please liaise with the Head of
Lighting in the lead up to the festival. Please note these specifications are subject to change.
6.
SOUND
The control position is located at the rear of the auditorium, it is not possible for one person to
operate both lighting and sound.
We do not allow companies to bring their own sound equipment.
System : L-Acoustics L&R Line array system with front fills – plans available on request.
Monitors: 4 x Floor monitors available
FOH Desk: Yamaha CL3 48 Input Digital Console with on board processing and effects
FOH Playback 1: 1 x Dedicated computer with sound replay/cue software
FOH Playback 2: 1 x 3.5mm Jack inputs
The basic rig also includes 4 wired dynamic SM58 microphones and 4 DI boxes.
For information and costs for radio microphones please contact the Head of Sound.
Additional microphones, other sound equipment and backline equipment is available for hire.
This equipment is provided by Assembly Theatre’s supplier and will be charged as an additional
cost – details on request.
All sound equipment must be agreed in advance with the Head of Sound or the Technical
Manager.
7.
DRESSING ROOM
8.
STORAGE
9.
ACCESS
This is shared by all companies performing in the venue and is located to the rear of the
venue.
Tables, chairs and mirrors are provided for communal use.
The management cannot accept responsibility for the security of any items left in the dressing
room.
You will have access to the storage and dressing room 40 minutes before and for 20 minutes
after your performance each day.
Backstage storage is extremely limited and we recommend that companies keep their
scenery/props requirements to an absolute minimum. Small items of scenery and props may
be stored in the dressing room at the discretion of the Technical Manager.
It is worth ensuring that your set is light yet durable enough to withstand daily dismantling.
ALL SET ITEMS ARE REQUIRED TO EASILY PASS THROUGH A STANDARD DOOR.
The access to central is an arched doorway 1.1m wide x 2.1m high.
Roxy Central is accessible from:
2 Roxburgh Place
Edinburgh
EH8 9SU
Load in and access is through a standard double door.
Please check before attempting to bring large pieces of scenery - they may not fit through the
doors.
Roxy Central
June 14
10.
STAFF
11.
NOTES
The theatre personnel work on a rota basis, the duty rota comprises one stage manager, one
lighting technician and one sound technician.
If the visiting manager requires additional staff to assist with the turn around, or the use of
casual crew during the load in or load out, then this can be organised at additional cost.
If the venue technical staff are required to participate for anything more than lights up /lights
down (one cue to bring the house to a performance state and mic live and then one cue to
bring the house back to exit state) during the performance, the Visiting Company will be liable
for a show call charge for each technician used.
The rate is £25 per performance per technician plus VAT.
Any additional staff or items of equipment, which the management are requested to provide,
will be charged to the visiting company.
Any practical electrical equipment you wish to use should have a current PAT certificate and be
cleared with us.
We reserve the right to refuse the use of any equipment which is deemed unsafe.
Each company is assigned a get in/rehearsal time prior to their first performance
This is the time for you to load your set and props into the venue and for you to re-tech your
show.
You will also need to allow sufficient time to rehearse your daily turnaround and set storage.
Please note that your slot time must include get-in and get-out time.
Please note that, due to the Scottish Executive regulations, smoking is not
permitted in any venues.
At the end of the festival, please arrange for removal or disposal of your set and any unused
publicity material. There will be a charge applied to cover the cost of disposal should you not
comply with this request.
Please note, since this is a temporary conversion and not a permanent theatre, all
measurement and quantities quoted in the above specification are approximate and may be
subject to change.
For detailed and up to date information regarding the venue please contact the Technical
Manager – [email protected].
Roxy Central
June 14
assembly 2013
Roxy Central
Initial Plans SUBJECT TO CHANGE
11/4/13
Note:
8110
Set store
sound &
LX control
698
5867
8000
Store
[email protected]
assembly 2013
Roxy Central
Initial Plans - Iso and
elevation
SUBJECT TO CHANGE
11/4/13
Note:
6112
5644 5959
535
[email protected]
1
2
3
4
5
6
7
A
A
44
34
L075
L134
45
35
L075
L134
303
46
36
L075
L134
304
B
B
41
31
42
32
43
33
L075
L134
L075
L134
L075
L134
drawing no
revision
sheet size
ROXYCLXFR14 1
A3
legend
X2
Instruments
X2
Used
C
C
MAC 700 Profile
2
S4 Zoom 25° - 50º
9
1.2kw Fresnel
18
Par 64 (CP 62)
4
House Light &
Working Light
5
Aisle Lights
4
Shelley
2003
54
4
©Steve
302
64MFL
301
64MFL
53
MAC Aura
700
PRO
25°-50°
64MFL
64MFL
64MFL
51
52
D
D
Legend
X3
L201
24
14
25
15
26
16
2003
L013
Shelley
L201
©Steve
L013
X1
Gobo 1
L013
Position
L201
Color
EXIT
EXIT
X3
Channel
Purpose
E
E
notes
LIGHTING CONTROL:
ETC ION
DIMMERS: 48 Channels
(31 used in fixed rig)
FIXED RIG MOVING LIGHTS
Available for Hire:
4 x Mac Aura (LED Wash)
2 x Mac 700 Profile Spots
L201
25°-50°
25°-50°
X1
L013
L201
L013
25°-50°
25°-50°
25°-50°
23
13
21
11
Shelley
©Steve
Shelley
©Steve
F
Dimmable House Lighting
2003
L013
25°-50°
2003
L201
700
700
PRO
PRO
701
22
12
702
F
NOTE: Lighting fixtures & plan are subject to
change. For most up to date plan, please
contact Assembly Head of Lighting.
information
client
Assembly Festival
project
Edinburgh Fringe Festival 2014
venue
R119
R119
R119
25°-50°
25°-50°
25°-50°
title
designer
X1
X3
X3
drawn
2
1
G
3
Roxy Central
Lighting Fixed Rig
AL
scale
1:50
date
09-06-2014
Assembly Festival
2 Roxburgh Place
Edinburgh EH8 9SU
T. +44 (0) 131 623 3000
http://www.assemblyfestival.com
1
2
3
4
5
6
7
G