patient dose qa
Transcription
patient dose qa
2-in-1 PATIENT DOSE QA with QuickCheckTM iba-dosimetry.com Not enough time for quality patient QA? QuickCheck™ with 3D Patient Dose QA is your efficiency choice for standard and complex treatment verification! YOUR 2-IN-1 PLAN VERIFICATION SOLUTION Verify your TPS plan QuickCheck™ Calculation Efficiency: Highest QA Efficiency e.g. for standard cases Save TPS time as no hybrid/phantom plan is required ULTIMATE QA EFFICIENCY: TPS Save measurement time and speed QuickCheck™ ULTIMATE 3D ACCURACY: COMPASS 3D Automatic Verification Understand the impact of dose discrepancies TPS Check up verification Rapid computation times: 7 beam IMRT Option 1 TPS in less than 1 min & VMAT Arc in 2-3 min Calculation TPS Check Compass reconstructed Calculation Accuracy: ull TPS class Collapsed Cone F re-calculation with Monte Carlo linac model 3D Dose Difference/ Gamma (local & global) ore powerful than simple MU checks M ull 3D dose calculation on real F patient CT 3D dose reconstruction & analysis in COMPASS Automatic QuickCheck evaluation gives you an instant “pass” or “evaluate” TPS Plan Verification Efficiency: Verify the plan in the patient anatomy: Fully automized fluence analysis in seconds 3D dose calculation reconstruction on real patient CT I nstant QA results display with “pass” or “evaluate” Verify your entire treatment chain igh-resolution ionization chamber H detectors with 50ms sampling time G amma or Dose difference displayed in just one look Avoid vendor dependencies by A utomatic evaluation based on your in-house protocols Measurement Highest QA Safety e.g. for complex cases Measurement Efficiency Head & Neck case Fast & easy detector setup with auto alignment Use your measured data for a fast QuickCheck evaluation or a full 3D dose reconstruction on the patient CT A utomatic PTV and OAR evaluation Verification Accuracy: analyzing linac log-files Delivery Check Automatic evaluation of the PTV and OAR evaluation 3 D dose reconstruction on real patient CT A utomatic email notification Measurement Accuracy Option 2 Optional Step Gantry based 360° measurements optimized for rotational cases QA Workflow Efficiency – save 20 min “ The COMPASS system provides fast and reliable 3D dose verification for clinical IMRT QA. The COMPASS QA process does not require phantom plans. Therefore, it allows a simple QA workflow.” Conclusion of publication: Nakaguchi Y et al.: (2014) Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA. Radiological Physics and Technology, 8(1), 73-80.. Segment/control point wise analysis verifiy the effect of segment errors on the total treatment accuracy Comparison of QA times between COMPASS, 3DVH, and EDR2 (Film) for 10 clinical IMRT/ VMAT plans Comprehensive reporting: Easy protocol template setup according to your needs Maximize Efficiency Better Outcome Minimize Errors A uto email notifications F lexible plan import with full DICOM conformance A ll patient data centralized in MS SQL Server database F ast template-based installation R apid computation times: 7 beam IMRT in less than 1 min & VMAT Arc in 2-3 min in a nutshell ass/Fail based on your P protocol Verify the source of deviations and understand the clinical relevance Replace human subjectivity TPS class collapsed cone algorithm ltimate QA flexibility for U simple as well as complex cases Comprehensive reporting uture integration in F global QA platform* Over 55 COMPASS Publications for Clinical & Scientific Background! Find publication list on the QuickCheck website. Your peers opinion: “The new QuickCheck enables an assessment to be automatically performed, for all cases, immediately after the measurement terminates. Customised tolerances for the QuickCheck assessment can be loaded on import of the plan to identify set-up issues, or unusual deviations from typical results. This helps to quickly identify problem cases so they can be dealt with early.” Kevin Brownsword, Medical Physicist Castle Hill Hospital, United Kingdom “The system is the best 3D solution out there. You can get 3D on patient anatomy in only 2 clicks.” Mathias Dierl, Head of Medical Physicists Clinical Center Bayreuth, Germany Europe, Middle East, Africa | +49 9128 6070 North America, Latin America | +1 901 386 2242 Asia Pacific | +86 10 8080 9288 [email protected] iba-dosimetry.com *Integration of QuickCheck / Compass in myQA is a work in progress. Currently not available for sale. “We are excited about many of the changes including a more efficient beam modeling process and significantly faster dose calculation.” Ryan Rivest, PhD, Medical Physicist Cancer Care, Canada “The system is such an exciting tool to use which provides us crucial calculation time saving and therefore much faster QA workflow.” Ghirmay Kidane, PhD, Consultant Radiotherapy Physicist BHR Hospitals, United Kingdom 2-in-1 Patient Dose QA with QuickCheck_RT-BR-E_Rev.1 | © IBA 2016 | All rights reserved | Manufacturer: IBA Dosimetry GmbH | Technical specifications and product features are subject to change without prior notice. 2-in1 Patient Dose QA with QuickCheck™
Similar documents
simplemu
*Nakaguchi Y et al.: (2014) Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA. Radiological Physics and Technology, 8(1), 73-80..
More information