Mini contactors • control relays, contactors, reversing
Transcription
Mini contactors • control relays, contactors, reversing
S014003 000623 Mini contactors • control relays, contactors, reversing contactors Mini contactors ... the benefits at a glance ... 4 basic coil versions ✓ AC : 4.5 VA DC : 2.4 W DC : 1.5 W ✓ AC with rectifier : 3.5 VA (hum-free, silent, no peak currents on make, insensitive to short voltage cutoffs). ✓ ✓ ✓ ✓ ✓ ✓ M 06 motor protection relay covering a range from 0.1 to 11.5 A Phase failure sensitive Electrically separate 1 N/O + 1N/C contacts Hand/auto reset Reset and setting parameters can be protected by sealable cover Control terminals are prewired Relay can be mounted beneath contactor KH ... CONTROL RELAY KL ..., KLW ... CONTACTORS PLUS SYSTEM COMPONENTS Control relay Versions : Screw terminals, Faston connectors or solder pins AC, DC, interface or hum-free coils Contactors Thermal overload relay Auxiliary contact block 2 or 4 pole Versions : Screw or Faston connection for top mounting Timer module Delay on energization 1 to 30 secs Versions : 24 to 48 V AC/DC 110 to 240 V AC front mounting Coil suppressor Versions : RC, varistor or diode front mounting Reversing contactor Versions : Screw terminals, Faston connectors or solder pins AC, DC, interface or hum-free coils Broad coil voltage range ensures reliable operation Integral or external coil suppressors give reliable protection to electronics 2- or 4-pole snap-on auxiliary contact blocks to increase the number or contacts Compact size saves space Separation of contacts ensured by forced opening of contacts Maximum shock resistance through specially designed magnetic system Contact reliability through special contacts Safe transmission of low-level signals Improved life at AC 3/AC 4 duty through optimized arc chutes and contact materials Suitable for resistive loads (AC 1): contacts are designed for Ith = 29 A at 50°C 1635 S014004 000919 Control relays KH ..., AC operated without integral coil suppressor Terminal numbering to DIN EN 50 011 Compact design Available in 3 versions : - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency coils 50/60 Hz High contact reliability Forced opening of contacts Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals : Further notes at the bottom of this page. Characteristics of control relays KH ..., AC operated, 4.5 VA coils Version with screw terminals Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHS-31 1 309 060 .. 3 1 KHS-22 1 309 070 .. 2 2 KHS-40 1 309 050 .. 4 0 Circuit diagram to DIN EN 50 011 Features Weight kg For dimensions see page 1673 0.180 - 50/60 Hz coil - without integral coil suppressor 0.180 0.180 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHF-31 1 309 160 .. 3 1 KHF-22 1 309 170 .. 2 2 KHF-40 1 309 150 .. 4 0 Circuit diagram to DIN EN 50 011 Features Weight kg For dimensions see page 1673 0.180 - 50/60 Hz coil - without integral coil suppressor 0.180 0.180 Version with solder pins, 1.7 mm Ø, hole on p. c. b. Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHL-31 1 309 260 .. 3 1 KHL-22 1 309 270 .. 2 2 KHL-40 1 309 250 .. 4 0 Circuit diagram to DIN EN 50 011 Features 0.210 - 50/60 Hz coil - without integral coil suppressor 1) 1636 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 0.210 0.210 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request Weight kg Auxiliary contact block - page 1641 Other system components - page 1641 Technical details - pages 1664, 1666 For dimensions see page 1673 S014005 000919 Control relays KH ..., AC operated with integral coil suppressor Terminal numbering to DIN EN 50 011 Compact design Available in 3 versions : - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency coils 50/60 Hz High contact reliability Forced opening of contacts Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for control relays KH ..., AC operated, 4.5 VA coils Version with screw terminals Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHS-31 1 309 062 .. 3 1 KHS-22 1 309 072 .. 2 2 KHS-40 1 309 052 .. 4 0 Circuit diagram to DIN EN 50 011 Features - with integral coil suppressor Weight kg For dimensions see page 1673 0.180 0.180 - permitted up to 240 V max. 0.180 Features Weight kg Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHF-31 1 309 162 .. 3 1 KHF-22 1 309 172 .. 2 2 KHF-40 1 309 152 .. 4 0 Circuit diagram to DIN EN 50 011 - with integral coil suppressor For dimensions see page 1673 0.180 0.180 - permitted up to 240 V max. 0.180 Features Weight kg Version with solder pins, 1.7 mm Ø, hole on p. c. b. Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHL-31 1 309 262 .. 3 1 KHL-22 1 309 272 .. 2 2 KHL-40 1 309 252 .. 4 0 Circuit diagram to DIN EN 50 011 - with integral coil suppressor For dimensions see page 1673 0.210 0.210 - permitted up to 240 V max. 0.210 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V AC-coils available with integral coil suppressor to max. 230 V 1) Auxiliary contact block - page 1641 Other system components - page 1641 Technical details - pages 1664, 1666 Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 1637 S014006 000919 Control relays KHDC ..., DC operated without integral coil suppressor Terminal numbering to DIN EN 50 011 Compact design Available in 3 versions : - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Forced opening of contacts Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 Further notes at the bottom of this page. Approvals: Characteristics for control relays KHDC ..., DC operated, 3 W coils Versions with screw terminals Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCS-31 1 309 065 .. 3 1 KHDCS-22 1 309 075 .. 2 2 KHDCS-40 1 309 055 .. 4 0 Circuit diagram to DIN EN 50 011 Features Weight kg For dimensions see page 1673 0.225 - without integral coil suppressor 0.225 0.225 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCF-31 1 309 165 .. 3 1 KHDCF-22 1 309 175 .. 2 2 KHDCF-40 1 309 155 .. 4 0 Circuit diagram to DIN EN 50 011 Features Weight kg For dimensions see page 1673 0.225 - without integral coil suppressor 0.225 0.225 Version with solder pins, 1.7 mm Ø, hole on p. c. b. Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCL-31 1 309 265 .. 3 1 KHDCL-22 1 309 275 .. 2 2 KHDCL-40 1 309 255 .. 4 0 Circuit diagram to DIN EN 50 011 Features 0.225 - without integral coil suppressor 1) 1638 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 0.225 0.225 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request Weight kg Auxiliary contact block - page 1641 Other system components - page 1641 Technical details - pages 1664, 1666 For dimensions see page 1673 S014007 000919 Control relays KHDC ..., DC operated with integral coil suppressor Terminal numbering to DIN EN 50 011 Compact design Available in 3 versions : - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Forced opening of contacts Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 Further notes at the bottom of this page. Approvals: Characteristics for control relays KHDC ..., DC operated, 3 W coils Version with screw terminals Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCS-31 1 309 066 .. 3 1 KHDCS-22 1 309 076 .. 2 2 KHDCS-40 1 309 056 .. 4 0 Circuit diagram to DIN EN 50 011 Features - with integral coil suppressor Weight kg For dimensions see page 1673 0.225 0.225 - permitted up to 240 V max. 0.225 Features Weight kg Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCF-31 1 309 166 .. 3 1 KHDCF-22 1 309 176 .. 2 2 KHDCF-40 1 309 156 .. 4 0 Circuit diagram to DIN EN 50 011 - with integral coil suppressor For dimensions see page 1673 0.225 0.225 - permitted up to 240 V max. 0.225 Features Weight kg Version with solder pins, 1.7 mm Ø, hole on p. c. b. Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHDCL-31 1 309 266 .. 3 1 KHDCL-22 1 309 276 .. 2 2 KHDCL-40 1 309 256 .. 4 0 Circuit diagram to DIN EN 50 011 - with integral coil suppressor For dimensions see page 1673 0.225 0.225 - permitted up to 240 V max. 0.225 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V DC-coils available with integral coil suppressor to max. 220 V 1) Auxiliary contact block - page 1641 Other system components - page 1641 Technical details - pages 1664, 1666 Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 1639 S014008 000919 Control relays KHi (interface), DC operated with integral coil suppressor and LED to indicate operational state Terminal numbering to DIN EN 50 011 Compact design, same size as AC control relay Version : - with screw terminals Low power consumption coils High contact reliability Switch position indication Positively guided terminals Can be directly controlled by programmable controller Safety isolation up to 400 V to VDE 0106, IEC 536 Further notes at the bottom of this page. Approvals: Characteristics for contol relays KHiS ..., DC operated, interface, 1.8 W coil Version with screw terminals Rated thermal current Ith A 10 Type Order ref.: see supplements at the top right Contact configuration N/O N/C KHiS-31 1 309 067 06 3 1 KHiS-22 1 309 077 06 2 2 KHiS-40 1 309 057 06 4 0 Circuit diagram to DIN EN 50 011 Features - built-in LED to indicate operational state - Coil operating voltage rangs 0.7 to 1.3 VC - integral coil suppressor - only 2 pole aux. contact block permitted Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1640 DC: 24 and 48 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1641 Other system components - page 1641 Technical details - pages 1664, 1666 Weight kg 0.235 0.235 0.235 For dimensions see page 1673 000919 S014009 Mini contactors: system components for use with control relays, contactors, and reversing contactors Auxiliary contact blocks, 2- or 4-pole, front fitting Compact in size, mounts quickly Available in 2 versions : S = screw terminals F = Faston connectors Contact positioning and numbering to DIN EN 50011 on types HS/HF when mounted to control relays with 4 N/O contacts When mounted to contactors, DIN EN 50012 is maintained when LS contacts are used High contact reliability Switch position indication 3 front mounting coil suppressor versions with LED indicators Front mounting timer module, delay on energization up to 30 secs Approvals: Characteristics Auxiliary contact blocks for use with KL ..., KLW contactors for use with KH ..., KHDC ..., KHi control relays Coil suppressors with built-in LED indicator RC coil suppressor (for AC operated contactor) Top mounting for contactors Type DIN EN 50 012 LS-11 3 309 001 01 LS-02 3 309 002 01 Type Voltage range Order ref.: LS-13 3 309 005 01 D-242) D-482) 12...24 = 32...48 = 3 309 061 01 3 309 061 02 LS-22 3 309 004 01 LS-31 3 309 003 01 KL ... KLW ... Circuit diagram Order ref.: Type Voltage range Order ref.: RC-2501) 220...250 V 3 309 062 01 Diode coil suppressor (for DC operated contactor) Varistor coil suppressor (for AC or DC operated contactor) Type 3) HS-02 3 309 033 01 HF-02 3 309 043 01 HS-04 3 309 038 01 HF-04 3 309 048 01 HS-11 3 309 032 01 HF-11 3 309 042 01 KH, KHDC, HS-13 3 309 037 01 KHi HF-13 3 309 047 01 HS-20 3 309 031 01 HF-20 3 309 041 01 HS-22 3 309 036 01 HF-22 3 309 046 01 HS-31 3 309 035 01 HF-31 3 309 045 01 HS-40 3 309 034 01 HF-40 3 309 044 01 Weight : 0.045 kg V-24 V-483) V-1303) V-2503) Voltage range Order ref.: 12...24 AC/DC 32...48 AC/DC 40...129 AC/DC 130...250 AC/DC 3 309 060 01 3 309 060 02 3 309 060 04 3 309 060 05 Weight : 0.010 kg Timer module snaps to the front of contactor Type Timer range Voltage range input/coil Order ref.: HV-48 HV-240 1...30 1...30 24...48 V AC/DC 110...240 V AC 3 309 050 01 3 309 050 02 Weight : 0.040 kg Technical details : Relay outputs 240 V AC/DC, 2 A max. Max. switching capacity 250 VA / 150 W Control voltage range 0.85...1.1 VC Permissible ambient temperature -10°C ... +60°C Reset time : 1.5 secs while timing 0.5 secs after timing Circuit diagram : 1W Explanation : ... S = screw terminals ... F = Faston connectors on KHi only 2-pole versions permitted ! Notes 1) 2) 3) Limits transient voltage to max. 3 Vc. Slight increase in drop-out time (1.2 to 2 times the normal time). No interference by transient voltages and high frequency. Observe polarity when connecting. Slight increase in drop-out time (1.1 to 1.5 times the normal time). Limits transient voltages to max. 2 Vc. Max. reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time). Technical details - pages 1664-1666 Dimensions - page 1673 1641 S014010 000623 Contactors KL ..., 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) AC operated, Terminal numbering to DIN EN 50 005 and without integral coil suppressor DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 KL contactors are designed to switch three-phase and AC loads. Applications include building automation, air conditioning, heating and ventilation, and switching resistive loads such as heaters, lamps, and inductive loads, e.g., valves, couplings, etc. Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for contactors KL ..., AC operated, 4.5 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay Version with screw terminals 1.5 2.2 2.2 4 3 4 3 4 KL2S-10 1 309 000 .. KL2S-01 1 309 010 .. - 50/60 Hz coil KL4S-10 1 309 020 .. - without integral coil suppressor KL4S-01 1 309 030 .. 20/6 20/9 0.180 M 06 0.180 M 06 0.210 M 06 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 1.5 2.2 2.2 4 3 4 3 4 KL2F-10 1 309 100 .. KL2F-01 1 309 110 .. - 50/60 Hz coil KL4F-10 1 309 120 .. - without integral coil suppressor KL4F-01 1 309 130 .. 20/6 20/9 Version with solder pins, 1,7 mm Ø, hole on p. c. b. 1.5 2.2 2.2 4 3 4 3 4 KL2L-10 1 309 200 .. KL2L-01 1 309 210 .. - 50/60 Hz coil KL4L-10 1 309 220 .. - without integral coil suppressor KL4L-01 1 309 230 .. 20/6 20/9 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1642 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 For dimensions see page 1673 S014011 000919 Contactors KL ..., 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) AC operated, with integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 KL contactors are designed to switch three-phase and AC loads. Applications include building automation, air conditioning, heating and ventilation, and switching resistive loads such as heaters, lamps, and inductive loads, e.g., valves, couplings, etc. Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for contactors KL ..., AC operated, 4.5 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay For dimensions see page 1673 Version with screw terminals KL2S-10 1.5 2.2 2.2 4 3 4 3 4 1 309 002 .. - 50/60 Hz coil KL2S-01 1 309 012 .. - with integral coil suppressor KL4S-10 1 309 022 .. KL4S-01 1 309 032 .. 20/6 0.180 M 06 0.180 M 06 0.210 M 06 20/9 permitted up to 240 V max. Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm KL2F-10 1.5 2.2 2.2 4 3 4 3 4 1 309 102 .. - 50/60 Hz coil KL2F-01 1 309 112 .. - with integral coil suppressor KL4F-10 1 309 122 .. KL4F-01 1 309 132 .. 20/6 20/9 permitted up to 240 V max. Version with solder pins, 1,7 mm Ø, hole on p. c. b. KL2L-10 1.5 2.2 2.2 4 3 4 3 4 1 309 202 .. - 50/60 Hz coil KL2L-01 1 309 212 .. - with integral coil suppressor KL4L-10 1 309 222 .. KL4L-01 1 309 232 .. 20/6 20/9 permitted up to 240 V max. Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V AC-coils available with integral coil suppressor to max. 230 V 1) Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 1643 S014012 000919 Contactors KLDC ..., 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) DC operated, without integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 KLDC contactors are designed to switch three-phase and AC loads. Applications include building automation, air conditioning, heating and ventilation, and switching resistive loads such as heaters, lamps, and inductive loads, e.g., valves, couplings, etc. Further notes at the bottom of this page. Approvals: Characteristics for contactors KLDC ..., DC operated, 3 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay Version with screw terminals 1.5 2.2 2.2 4 3 4 3 4 KLDC2S-10 1 309 005 .. KLDC2S-01 1 309 015 .. KLDC4S-10 1 309 025 .. KLDC4S-01 1 309 035 .. 20/6 - without integral coil suppressor 0.225 M 06 - without integral coil suppressor 0.225 M 06 - without integral coil suppressor 0.225 M 06 20/9 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 1.5 2.2 2.2 4 3 4 3 4 KLDC2F-10 1 309 105 .. KLDC2F-01 1 309 115 .. KLDC4F-10 1 309 125 .. KLDC4F-01 1 309 135 .. 20/6 20/9 Version with solder pins, 1,7 mm Ø, hole on p. c. b. 1.5 2.2 2.2 4 3 4 3 4 KLDC2L-10 1 309 205 .. KLDC2L-01 1 309 215 .. KLDC4L-10 1 309 225 .. KLDC4L-01 1 309 235 .. 20/6 20/9 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1644 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 For dimensions see page 1673 S014013 000919 Contactors KLDC ..., 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) DC operated with integral coil suppressor Terminal numbering DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 KLDC contactors are designed to switch three-phase and AC loads. Applications include building automation, air conditioning, heating and ventilation, and switching of resistive loads such as heaters, lamps, and inductive loads, e.g., valves, couplings, etc. Further notes at the bottom of this page. Approvals: Characteristics for contactors KLDC ..., DC operated, 3 W coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay For dimensions see page 1673 Version with screw terminals 1.5 2.2 2.2 4 3 4 3 4 KLDC2S-10 1 309 006 .. KLDC2S-01 1 309 016 .. KLDC4S-10 1 309 026 .. KLDC4S-01 1 309 036 .. 20/6 - with integral coil suppressor 0.225 M 06 0.225 M 06 0.225 M 06 20/9 permitted up to 240 V max. Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 1.5 2.2 2.2 4 3 4 3 4 KLDC2F-10 1 309 106 .. KLDC2F-01 1 309 116 .. KLDC4F-10 1 309 126 .. KLDC4F-01 1 309 136 .. 20/6 - with integral coil suppressor 20/9 permitted up to 240 V max. Version with solder pins, 1,7 mm Ø, hole on p. c. b. 1.5 2.2 2.2 4 3 4 3 4 KLDC2L-10 1 309 206 .. KLDC2L-01 1 309 216 .. KLDC4L-10 1 309 226 .. KLDC4L-01 1 309 236 .. 20/6 - with integral coil suppressor 20/9 permitted up to 240 V max. Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V DC-coils available with integral coil suppressor to max. 220 V 1) Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 1645 S014014 000731 Interface contactors KLi ... 4 kW / 5 HP at 460 V, 3 ph. (AC 3) DC operated, with integral coil suppressor and LED switch position indication Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Switch position indication Can be directly controlled by programmable controllers Safety isolation up to 400 V to VDE 0106, IEC 536 Further notes at the bottom of this page. Approvals: Characteristics for contactors KLi ..., DC operated, 1.8 W coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay Version with screw terminals 2.2 4 4 4 KLi4S-10 1 309 027 .. KLi4S-01 1 309 037 .. 20/9 - Built in LED to indicate switch position - Coil voltage range from 0.7 to 1.3 Vc - Integral coil suppressor up to 72 V max. - Only 2 pole aux. contact block permitted 0.235 M 06 0.235 M 06 0.265 M 06 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 2.2 4 4 4 KLi4F-10 1 309 127 .. KLi4F-01 1 309 137 .. 20/9 - Built in LED to indicate switch position - Coil voltage range from 0.7 to 1.3 Vc - Integral coil suppressor up to 72 V max. - Only 2 pole aux. contact block permitted Version with solder pins, 1,7 mm Ø, hole on p. c. b. 2.2 4 4 4 KLi4L-10 1 309 227 .. KLi4L-01 1 309 237 .. 20/9 - Buil-in LED to indicate switch position - Coil voltage range from 0.7 to 1.3 Vc - Integral coil suppressor up to 72 V max. - Only 2 pole aux. contact block permitted Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1646 DC: 24 and 48 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 For dimensions see page 1673 S014015 000623 Contactors KLb ..., 4 kW / 5 HP at 460 V, 3 ph. (AC 3) AC operated, with integral coil suppressor hum-free for special applications Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 - KLi contactors are hum free which makes them suitable for use in building equipment, etc. - Magnet coil with integral rectifier and coil suppressor - Suitable for rail mounting (35 mm rail) or screw fixing (4 mm dia. screws) - Connecting screws are supplied with the clamps in the open position Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for contactors KLb ..., AC operated, 3 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to Features DIN EN 50 005 and DIN EN 50 012 Weight Suitable kg thermal overload relay For dimensions see page 1673 Version with screw terminals 50/60 Hz coil 24 V 110 V KLb4S-10 2.2 4 4 4 1 309 021 .. 20/9 KLb4S-01 1 309 031 .. 230 V permitted 0.225 M 06 0.225 M 06 0.225 M 06 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 50/60 Hz coil 24 V 110 V KLb4F-10 2.2 4 4 4 1 309 121 .. 20/9 KLb4F-01 1 309 131 .. 230 V permitted Version with solder pins, 1,7 mm Ø, hole on p. c. b. 50/60 Hz coil 24 V 110 V KLb4L-10 2.2 4 4 4 1 309 221 .. 20/9 KLb4L-01 1 309 231 .. 230 V permitted Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) AC: 24, 110 and 230 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 1647 S014016 000623 Reversing contactors KLW ..., 3 pole 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) AC operated, without integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 - Mechanically interlocked as standard - Main circuit is ready wired on contactors with screw terminals - Suitable for rail mounting (35 mm rail) or screw fixing (4 mm dia. screw) - Connecting screws are supplied with the clamps in the open position Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for reversing contactors KLW ..., AC operated, 4.5 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to DIN EN 50 005 and DIN EN 50 012 Features Weight Suitable kg thermal overload relay Version with screw terminals 1.5 2.2 2.2 4 3 4 3 4 KLW2S-10 1 309 300 .. KLW2S-01 1 309 310 .. KLW4S-10 1 309 320 .. KLW4S-01 1 309 330 .. 20/6 without integral coil suppressor 0.39 M 06 without integral coil suppressor 0.37 M 06 without integral coil suppressor 0.43 M 06 20/9 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 1.5 2.2 2.2 4 3 4 3 4 KLW2F-10 1 309 400 .. KLW2F-01 1 309 410 .. KLW4F-10 1 309 420 .. KLW4F-01 1 309 430 .. 20/6 20/9 Version with solder pins, 1,7 mm Ø, hole on p. c. b. 1.5 2.2 2.2 4 3 4 3 4 KLW2L-10 1 309 500 .. KLW2L-01 1 309 510 .. KLW4L-10 1 309 520 .. KLW4L-01 1 309 530 .. 20/6 20/9 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1648 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 For dimensions see page 1673 S014017 000623 Reversing contactors KLW ..., 3 pole 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) AC operated, with integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 - Mechanically interlocked as standard - Main circuit is ready wired on contactors with screw terminals - Suitable for rail mounting (35 mm rail) or screw fixing (4 mm dia. screw) - Connecting screws are supplied with the clamps in the open position Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Further notes at the bottom of this page. Approvals: Characteristics for reversing contactors KLW ..., AC operated, 4.5 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to DIN EN 50 005 and DIN EN 50 012 Features Weight Suitable kg thermal overload relay For dimensions see page 1673 Version with screw terminals 1.5 2.2 2.2 4 3 4 3 4 with integral coil suppressor KLW2S-10 1 309 302 .. KLW2S-01 1 309 312 .. KLW4S-10 1 309 322 .. KLW4S-01 1 309 332 .. permitted up to 240 V max. KLW2F-10 1 309 402 .. with integral coil suppressor KLW2F-01 1 309 412 .. KLW4F-10 1 309 422 .. KLW4F-01 1 309 432 .. permitted up to 240 V max. KLW2L-10 1 309 502 .. with integral coil suppressor KLW2L-01 1 309 512 .. KLW4L-10 1 309 522 .. KLW4L-01 1 309 532 .. 20/6 0.39 M 06 0.37 M 06 0.43 M 06 20/9 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 1.5 2.2 2.2 4 3 4 3 4 20/6 20/9 Version with solder pins, 1,7 mm Ø, hole on p. c. b. 1.5 2.2 2.2 4 3 4 3 4 20/6 20/9 permitted up to 240 V max. Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V AC-coils available with integral coil suppressor to max. 230 V 1) Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 1649 S014018 000731 Reversing contactors KLWDC ..., 3 pole 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) DC operated, without integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Switch position indication With or without integral coil suppressor Safety isolation up to 400 V to VDE 0106, IEC 536 - Mechanically interlocked as standard - Main circuit is prewired on contactors with screw terminals - Suitable for rail mounting (35 mm rail) or screw fixing (4 mm dia. screw) - Connecting screws are supplied with the clamps in the open position Further notes at the bottom of this page. Approvals: Characteristics for reversing contactors KLWDC ..., DC operated, 3 W coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to DIN EN 50 005 and DIN EN 50 012 Features Weight Suitable kg thermal overload relay Version with screw terminals KLWDC2S-10 1 309 305 .. 1.5 2.2 3 3 20/6 KLWDC2S-01 1 309 315 .. KLWDC4S-10 1 309 320 .. 2.2 4 4 4 without integral coil suppressor 0.39 M 06 without integral coil suppressor 0.39 M 06 without integral coil suppressor 0.39 M 06 20/9 KLWDC4S-01 1 309 335 .. Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm KLWDC2F-10 1 309 405 .. 1.5 2.2 3 3 20/6 KLWDC2F-01 1 309 415 .. KLWDC4F-10 1 309 320 .. 2.2 4 4 4 20/9 KLWDC4F-01 1 309 435 .. Version with solder pins, 1,7 mm Ø, hole on p. c. b. KLWDC2L-10 1 309 505 .. 1.5 2.2 3 3 20/6 KLWDC2L-01 1 309 515 .. KLWDC4L-10 1 309 320 .. 2.2 4 4 4 20/9 KLWDC4L-01 1 309 535 .. Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1650 DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 For dimensions see page 1673 S014019 000731 Reversing contactors KLWDC ..., 3 pole 2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3) DC operated, with integral coil suppressor Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 - Mechanically interlocked as standard - Main circuit is prewired on contactors with screw terminals - Suitable for rail mounting (35 mm rail) or screw attached (4 mm dia. screw) - Connecting screws are supplied with the clamps in the open position Further notes at the bottom of this page. Approvals: Characteristics for reversing contactors KLWDC ..., DC operated, 3 W coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to DIN EN 50 005 and DIN EN 50 012 Features Weight Suitable kg thermal overload relay For dimensions see page 1673 Version with screw terminals KLWDC2S-10 1 309 306 .. 1.5 2.2 3 3 20/6 with integral coil suppressor KLWDC2S-01 1 309 316 .. 0.48 M 06 0.46 M 06 0.52 M 06 KLWDC4S-10 1 309 326 .. 2.2 4 4 4 20/9 KLWDC4S-01 1 309 336 .. permitted up to 240 V Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm KLWDC2F-10 1 309 406 .. 1.5 2.2 3 3 20/6 with integral coil suppressor KLWDC2F-01 1 309 416 .. KLWDC4F-10 1 309 426 .. 2.2 4 4 4 20/9 KLWDC4F-01 1 309 436 .. permitted up to 240 V Version with solder pins, 1,7 mm Ø, hole on p. c. b. KLWDC2L-10 1 309 506 .. 1.5 2.2 3 3 20/6 with integral coil suppressor KLWDC2L-01 1 309 516 .. KLWDC4L-10 1 309 526 .. 2.2 4 4 4 20/9 KLWDC4L-01 1 309 536 .. permitted up to 240 V Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request DC: 24, 110 and 220 V DC-coils available with integral coil suppressor to max. 220 V 1) Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - pages 1664-1665 Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K 1651 S014020 000623 Reversing contactors KLWb ..., 3 pole 4 kW / 5 HP at 460 V, 3 ph. (AC 3) AC operated, hum-free for special applications Terminal numbering to DIN EN 50 005 and DIN EN 50 012 Compact design Available in 3 versions: - with screw terminals - Faston connectors - solder pins Version with solder pins includes front face screw terminals for direct connection to load Low power consumption coils Bi-frequency AC coils 50/60 Hz High contact reliability Switch position indication Safety isolation up to 400 V to VDE 0106, IEC 536 - KLWb contactors are hum-free which makes them suitable for use in building equipment, etc. - Magnet coil with integral rectifier and coil suppressor - Mechanically interlocked as standard - Main circuit is prewired on contactor with screw terminals - Suitable for rail mounting (35 mm rail) or screw attached (4 mm dia. screw) - Connecting screws are supplied with the clamps in the open position Our mini contactors are delivered with bi-frequency coils for 50/60 Hz. Approvals: Further notes at the bottom of this page. Characteristics for reversing contactors KLWb ..., AC operated, 3 VA coils Max. AC 3 ratings of 3-phase motors (kW) 380... 230 V 415 V 500 V Rated operational current Ie AC 1/AC 3 up to 440 V 690 V A Contactor type Order ref.: see supplements at the top right Circuit diagram to DIN EN 50 005 and DIN EN 50 012 Features Weight Suitable kg thermal overload relay Version with screw terminals 50/60 Hz coil ... 24 V 2.2 4 4 4 KLWb4S-10 1 309 321 .. ... 110 V KLWb4S-01 1 309 331 .. permitted 0.48 M 06 0.46 M 06 0.52 M 06 ... 230 V 20/9 Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm 50/60 Hz coil ... 24 V KLWb4F-10 2.2 4 4 4 1 309 421 .. ... 110 V ... 230 V 20/9 KLWb4F-01 1 309 431 .. permitted Version with solder pins, 1,7 mm Ø, hole on p. c. b. 50/60 Hz coil ... 24 V 2.2 4 4 4 KLWb4L-10 1 309 521 .. ... 110 V KLWb4L-01 1 309 531 .. permitted ... 230 V 20/9 Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1652 AC: 24, 110 and 230 V Color code to IEC 309-1 printed on the coil. Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K Auxiliary contact block - page 1653 Other system components - page 1653 Technical details - page 1664-1665 For dimensions see page 1673 S014022 000623 Mini contactors: system components for use with control relays, contactors and reversing contactors Auxiliary contact blocks, 2- or 4-pole, front fitting Compact in size, mounts quickly Available in 2 versions : S = screw terminals F = Faston connectors Contact positioning and numbering to DIN EN 50011 on types HS/HF when mounted to control relays with 4 N/O contacts When mounted to contactors, DIN EN 50012 is maintained when LS contacts are used High contact reliability Switch position indication 3 front mounting coil suppressor versions with LED indicators Front mounting timer module, delay on energization up to 30 seconds Approvals: Characteristics Auxiliary contact blocks for use with KL ..., KLW contactors for use with KH ..., KHDC ..., KHi control relays Coil suppressors with built in LED indicator RC coil suppressor (for AC operated contactor) Top mounting for contactors Type DIN EN 50 012 LS-11 3 309 001 01 LS-02 3 309 002 01 Type Voltage range Order ref.: LS-13 3 309 005 01 D-242) D-482) 12...24 = 32...48 = 3 309 061 01 3 309 061 02 LS-22 3 309 004 01 LS-31 3 309 003 01 KL ... KLW ... Circuit diagram Order ref.: Type Voltage range Order ref.: RC-2501) 220...250 V 3 309 062 01 Diode coil suppressor (for DC operated contactor) Varistor coil suppressor (for AC or DC operated contactor) Type 3) HS-02 3 309 033 01 HF-02 3 309 043 01 HS-04 3 309 038 01 HF-04 3 309 048 01 HS-11 3 309 032 01 HF-11 3 309 042 01 KH, KHDC, HS-13 3 309 037 01 KHi HF-13 3 309 047 01 HS-20 3 309 031 01 HF-20 3 309 041 01 HS-22 3 309 036 01 HF-22 3 309 046 01 HS-31 3 309 035 01 HF-31 3 309 045 01 HS-40 3 309 034 01 HF-40 3 309 044 01 Weight : 0.045 kg V-24 V-483) V-1303) V-2503) Voltage range Order ref.: 12...24 AC/DC 32...48 AC/DC 40...129 AC/DC 130...250 AC/DC 3 3 3 3 309 309 309 309 060 060 060 060 01 02 04 05 Weight : 0.010 kg Timer module snaps to the front of contactor Type Timer range Voltage range input/coil Order ref.: HV-48 HV-240 1...30 1...30 24...48 V AC/DC 110...240 V AC 3 309 050 01 3 309 050 02 Weight : 0.040 kg Technical details : Relay outputs 240 V AC/DC, 2 A max. Max. switching capacity 250 VA / 150 W Control voltage range 0.85...1.1 VC Permissible ambient temperature -10°C ... +60°C Reset time : 1.5 secs while timing 0.5 secs after timing Circuit diagram : 1W Explanation : ... S = screw terminals ... F = Faston connectors on KHi only 2-pole versions permitted ! Notes 1) 2) 3) Limits transient voltage to max. 3 Vc. Slight increase in drop-out time (1.2 to 2 times the normal time). No interference by transient voltages and high frequency. Observe polarity when connecting. Slight increase in drop-out time (1.1 to 1.5 times the normal time). Limits transient voltages to max. 2 Vc. Max. reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time). Technical details - pages 1664-1666 Dimensions - page 1673 1653 S014021 000919 Voltage code numbers 04 ...73 to be added to the contactor order reference number for mini contactors Code number AC ... 04 ... 06 ... 10 ... 11 ... 13 ... 15 ... 19 ... 25 ... 28 ... 29 ... 38 ... 40 ... 41 ... 43 ... 59 ... 61 ... 63 ... 65 ... 69 ... 73 Color code1) for coil voltage DC 12 V 24 V 32 V 36 V 42 V 48 V 60 V 110 V 120 V 127 V 125 V 208 V 230 V 220 V 240 V 400 V 380 V 415 V 440 V 500 V 600 V 220 V AC DC violet violet violet green white white green yellow yellow yellow blue blue blue blue red red red red black black green green green green green green green green green green green green - Our control relays, compact contactors and mini contactors are delivered with bi-frequency coils for 50/60 Hz. Our N-contactors are available with mono-frequency coils for 50 or 60 Hz. Notes Normal/Standard voltages are: (Short-term availability) Other coil voltages on request 1) 1654 AC: 24, 42, 110, 230 and 400 V DC: 24, 110 and 220 V Color code to IEC 309-1 printed on the coil. Only for compact contactors HL 4 K / HL 8 K and DL 4 K - DL 18 K NOTES 1655 1002T 010329 Motor Controls Entrelec MTE is a leading supplier of motor control and protection products for a wide range of industrial applications. Products include innovative electronic equipment including soft-starters, DC injection brakes, and advanced motor protection and monitoring modules. All products are manufactured to ISO 9001 standards. Electronic Soft Starters: DuoSoft and PowerSoft DuoSoft DuoSoft and PowerSoft electronic soft starters provide smooth acceleration and deceleration of three phase motors, reducing mechanical and electrical stress which shorten a motor’s life. DuoSoft starters are suitable for motors up to 15 kW. PowerSoft starters come in two versions, a chassis model to incorporate into a separate enclosure and a complete ready-to-go starter suitable for wall mounting. DuoSoft • Suitable for motors up to 15 kW • Ideal alternative to Star Delta starters • Integral bypass relay • Compact size • Two or three wire control • LED status indication PowerSoft chassis model PowerSoft - chassis model PowerSoft - complete starter • The system integrator’s choice • Installs into a separate enclosure • Compact IP20 construction • Adaptable for a wide range of applications • The installers’ choice • For wall mounting • Self-contained IP55 unit (IP42 above 40 kW) • Easy to install • Incorporates isolator, line contactor, start stop buttons, and motor overload protection Contact Entrelec for details. Fuse Disconnect Switches ZNTF Fuse Switches ZNTF • Up to 100A rating. • Door interlocked handle standard • Two auxiliary contacts can be mounted • Auxiliaries feature early break/late make ZTF ZTF • Larger fuse switch to 800A rating • Includes door interlocked handle and fuse barriers • Four auxiliary contacts can be mounted • Fourth pole not fused • Auxiliaries feature early break/late make Contact Entrelec for details. 1656 1003T 010329 Motor Protection: Maxim Products for protecting, monitoring, and controlling motors. 50% of motor failures are triggered by overheating due to overload, phase failure, or insulation breakdown. A 10% temperature rise reduces your motor’s life by 50%. The Maxim range of products protect your motor against the cause of temperature rise. Devices within the range also provide protection against other causes of motor and equipment damage, including: • Dry pump • Belt break on conveyor or fan • Mixer jamming • Excess conveyor loading Contact Entrelec for details. Monitors 6 functions Monitors 16 functions with bus communication DC Injection Brakes Our DC Injection brakes reduce the time for a machine to come to rest resulting in an increased production output and increased safety in hazardous machines. Available in three formats with DOL starter, with Star Delta starter, and without starter (for use with existing DOL or Star Delta starter). • Reduced stopping time • Increased production cycle • Smooth controlled stopping • Adjustable braking torque and stop time • Easy installation • Maintenance free Meets the guidelines of PUWER 98, developed in the United Kingdom. Contact Entrelec for details. Power Manager Power Manager provides comprehensive electrical network information that economically replaces ammeters, voltmeters, meter switches, kWh meters, power factor meters, kW meters, and more. Compact and easy to use, Power Manager provides accurate measurement to the 20th Harmonic on each cycle. The combination of performance, simplicity, and size ensures that Power Manager is the ideal solution for switchboard and control panel manufacturers. • Simple to install Quick fit clamps for panel mounting and large cable terminals • Easy to use Four menu buttons allow information to be accessed easily and quickly • Accurate and comprehensive parameter measurement • Easy to read Large clear backlit LCD display • Compact size Contact Entrelec for details. 1657 NOTES 1658 S015003 000623 Fusing of squirrel cage motors 50 Hz 1500 r. p. m. up to and including 25 kW (guide values). For values applicable to contactors and thermal overload relays, see "technical details" Motor rating Motor rated current at 125 V Fusing DOL Y∆ Motor rated current at 230 V Fusing DOL Y∆ Motor rated current at 240 V Fusing DOL Y∆ Motor rated current at 400 V Fusing DOL Y∆ kW PS ≈ hp cos ϕ η% A A A A A A A A A A A A 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.8 1.1 1.5 2.2 2.5 3 3.7 4 5 5.5 6.5 7.5 8 11 12.5 15 18.5 20 22 25 0.08 0.12 0.16 0.24 0.34 0.5 0.75 1 1.1 1.5 2 3 3.4 4 5 5.5 6.8 7.5 8.8 10 11 15 17 20 25 27 30 34 0.7 0.7 0.7 0.7 0.7 0.72 0.75 0.8 0.8 0.83 0.83 0.83 0.83 0.84 0.84 0.84 0.84 0.85 0.85 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.87 0.87 59 60 61 61 62 64 69 74 74 77 78 81 81 81 82 82 83 83 84 85 85 87 87 87 88 88 89 89 0.67 0.99 1.29 1.93 2.69 3.7 4.4 5.9 6.3 7.8 10.7 15.2 17.3 20.4 25 26.8 33.1 36.4 42.2 47.6 - 2 2 4 4 4 6 10 10 16 16 20 25 25 35 35 35 50 63 63 63 - 2 2 2 4 4 4 6 10 10 10 16 20 20 25 35 36 50 50 50 50 - 0.38 0.55 0.76 1.1 1.4 2.1 2.7 3.3 3.6 4.9 6.2 8.7 9.8 11.6 14.2 15.3 18.9 20.6 23.7 27.4 28.8 39.2 43.8 52.6 64.9 69.3 75.2 84.4 1 2 2 2 4 4 4 6 6 10 10 16 16 20 25 25 35 35 35 35 50 63 63 80 100 100 100 125 1 2 2 2 2 4 4 4 4 6 10 10 16 16 20 20 25 25 25 35 35 50 50 63 80 80 80 100 0.35 0.5 0.68 1 1.38 1.93 2.3 3.1 3.3 4.1 5.6 7.9 8.9 10.6 13 14 17.2 18.9 21.8 24.8 26.4 35.3 40.2 48.2 58.7 63.4 68 77.2 1 2 2 2 4 4 4 6 6 6 10 16 16 20 25 25 25 35 35 35 35 50 63 80 80 80 100 100 1 2 2 2 2 4 4 4 4 6 10 10 10 16 16 20 20 25 25 35 35 50 50 63 63 80 80 100 0.22 0.33 0.42 0.64 0.88 1.22 1.5 2 2.1 2.6 3.5 5 5.7 6.6 8.2 8.5 10.5 11.5 13.8 15.5 16.7 22 25 30 37 40 44 50 1 1 2 2 2 4 4 4 4 4 6 10 10 16 16 16 20 20 25 25 25 35 35 50 63 63 63 80 1 1 2 2 2 2 2 4 4 4 4 6 10 10 10 10 16 16 16 20 20 25 35 35 50 50 50 63 Motor rating kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.8 1.1 1.5 2.2 2.5 3 3.7 4 5 5.5 6.5 7.5 8 11 12.5 15 18.5 20 22 25 PS ≈ hp 0.08 0.12 0.16 0.24 0.34 0.5 0.75 1 1.1 1.5 2 3 3.4 4 5 5.5 6.8 7.5 8.8 10 11 15 17 20 25 27 30 34 cos ϕ 0.7 0.7 0.7 0.7 0.7 0.72 0.75 10.8 0.8 0.83 0.83 0.83 0.83 0.84 0.84 0.84 0.84 0.85 0.85 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.87 0.87 η% 59 60 61 61 62 64 69 74 74 77 78 81 81 81 82 82 83 83 84 85 85 87 87 87 88 88 89 89 Motor rated current at 415 V Fusing DOL Y∆ Motor rated current at 440 V Fusing DOL Y∆ Motor rated current at 500 V Fusing DOL Y∆ Motor rated current at 600 V Fusing DOL Y∆ Motor rated current at 660 V Fusing DOL Y∆ A 2 2.5 3.5 5 6.5 7.5 11 14 21 28 35 40 - A 0.19 0.28 0.37 0.55 0.76 1.06 1.25 1.67 1.78 2.26 3.03 4.31 4.9 5.8 7.1 7.6 9.4 10.3 12 13.5 14.4 19.3 21.9 26.3 32 34.6 37.1 42.1 A 0.16 0.24 0.33 0.46 0.59 0.85 1.2 1.48 1.57 2.1 2.6 3.8 4.3 5.1 6.2 6.5 8.1 8.9 10.4 11.9 12.7 16.7 19 22.5 28.5 30.6 33 38 A 0.12 0.21 0.27 0.4 0.56 0.77 1.02 1.22 1.31 1.66 2.22 3.16 3.59 4.25 5.2 5.6 6.9 7.5 8.7 9.9 10.6 14.1 16.1 19.3 23.5 25.4 72.2 30.9 A 0.7 0.9 1.1 1.5 2 2.9 3.5 4.9 6.7 9 13 17.5 21 25 - A 4 4 6 10 16 16 20 25 35 35 50 63 - A 4 4 4 6 10 10 16 16 25 35 50 50 - A 1 1 1 1 2 2 4 4 4 4 6 6 10 10 16 16 16 20 20 25 25 35 35 35 50 50 63 63 A 1 1 1 1 2 2 2 2 2 4 4 6 6 10 10 10 16 16 16 16 20 25 25 35 35 50 50 50 A 1 1 1 1 2 2 4 4 4 4 4 6 6 10 16 16 16 16 20 20 20 25 35 35 50 50 50 63 A 1 1 1 1 2 2 2 2 2 4 4 6 6 10 10 10 10 10 16 16 16 20 25 25 35 35 50 50 A 1 1 1 1 1 2 2 4 4 4 4 6 6 6 10 10 16 16 16 16 20 25 25 35 35 35 35 50 A 1 1 1 1 1 2 2 2 2 2 4 4 4 6 10 10 10 10 10 16 16 20 20 25 25 35 35 35 A 2 2 2 4 4 6 6 10 16 16 25 25 35 35 - A 2 2 2 2 4 4 4 6 10 10 16 20 25 35 - The motor rated currents are valid for normal internal and surface cooled-down three-phase current motors of 1500 r. p. m. Direct-on-line-starting: Starting current max. 6 x motor rated current. Starting time: max. 5 sec. Y/∆-current: Starting current max. 2 x motor rated current. Starting time max. 15 s. Thermal overload relay in the delta circuit to be set at 0.58 x motor rated current. The rated currents of the fuse at Y/∆ -starting are also applicable for asynchronous slip-ring motors. At higher motor rated currents, starting currents, and/or longer starting times a higher-rated fuse has to be applied. This table is also applicable for "gL" fuses (DIN VDE 0636). Using NH-fuses in aM-characteristics fuse rating = motor rated current has to be selected. 1659 S015004 000919 Fusing of squirrel motors 50 Hz 1500 r. p. m. 30 kW and over (guide values). For values applicable to contactors and thermal overload relays, see "technical details" Motor rating Motor rated current at 125 V Fusing DOL Y∆ Motor rated current at 230 V Fusing DOL Y∆ Motor rated current at 240 V Fusing DOL Y∆ Motor rated current at 400 V Fusing DOL Y∆ kW PS ≈ hp cos ϕ η% A A A A A A A A A A A A 30 37 40 45 51 55 63 75 80 90 100 110 129 132 140 147 160 180 184 200 220 250 257 270 315 355 400 450 40 50 54 60 70 75 85 100 110 125 136 150 175 180 190 200 220 245 250 270 300 340 350 367 430 483 545 612 0.87 0.87 0.87 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.89 0.89 0.89 90 90 90 91 91 91 91 91 91 92 92 92 92 92 92 93 93 93 93 93 93 93 93 93 93 95 96 96 - - - 101 124 134 150 168 181 207 245 260 292 325 358 420 425 449 472 502 578 590 626 700 803 826 867 990 - 125 160 160 200 200 250 250 315 315 400 400 500 500 500 630 630 630 800 800 800 1000 1000 1000 1000 1250 - 125 160 160 160 200 200 200 250 315 315 400 400 500 500 500 630 630 630 630 800 800 1000 1000 1000 1250 - 92,7 114 123 136 154 166 190 226 241 268 297 327 384 393 416 432 471 530 541 589 647 736 756 794 927 - 125 160 160 200 200 200 200 315 315 315 400 400 500 500 500 630 630 630 630 800 800 1000 1000 1000 1250 - 100 125 160 160 200 200 200 250 250 315 400 400 400 500 500 500 630 630 630 630 800 800 800 800 1000 - 60 72 79 85 97 105 119 140 147 170 188 205 242 245 260 273 295 333 340 370 408 460 475 499 580 636 710 800 80 100 100 125 125 160 160 200 200 250 250 250 315 315 315 315 400 400 400 500 500 630 630 630 800 800 1000 1000 63 80 100 100 100 125 125 160 160 200 250 250 250 250 315 315 315 400 400 400 500 500 630 500 630 800 800 1000 Motor rating kW 30 37 40 45 51 55 63 75 80 90 100 110 129 132 140 147 160 180 184 200 220 250 257 270 315 355 400 450 1660 PS ≈ hp 40 50 54 60 70 75 85 100 110 125 136 150 175 180 190 200 220 245 250 270 300 340 350 367 430 483 545 612 cos ϕ 0.87 0.87 0.87 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.89 0.89 0.89 η% 90 90 90 91 91 91 91 91 91 92 92 92 92 92 92 93 93 93 93 93 93 93 93 93 93 95 96 96 Motor rated current at 415 V Fusing DOL Y∆ Motor rated current at 440 V Fusing DOL Y∆ Motor rated current at 500 V Fusing DOL Y∆ Motor rated current at 600 V Fusing DOL Y∆ Motor rated current at 660 V Fusing DOL Y∆ A 55 66 80 112,5 135 165 200 230 260 325 385 450 467 - A 50.1 61.9 67 37.9 83.8 90.3 103.5 123 131 146 162 178 209 214 227 236 256 289 295 321 353 401 412 433 505 549 611 688 A 44 54 60 64.5 73.7 79 90.5 106 112 128 143 156 184 186 200 207 220 254 259 278 310 353 363 381 445 483 538 608 A 37.1 45.4 49.1 54.2 61.4 66.2 76 90.3 96.3 107 119 131 153 157 167 173 188 212 217 325 260 295 302 317 370 405 450 508 A 33 42 49 60 82 98 118 140 170 215 268 337 366 410 460 A 80 100 100 160 200 200 250 315 315 400 500 630 630 - A 63 80 100 125 160 200 250 250 315 400 400 500 500 - A 80 80 100 100 125 125 125 160 160 200 200 250 250 250 315 315 315 400 400 400 500 500 500 500 630 800 800 800 A 63 80 80 80 100 100 100 160 160 160 200 200 250 250 250 250 315 315 315 400 400 500 500 500 630 630 800 800 A 63 80 80 100 100 125 125 160 160 160 200 200 250 250 250 250 315 315 315 315 400 500 500 500 630 630 630 800 A 50 63 63 80 80 100 100 125 125 160 160 200 200 200 250 250 250 315 315 315 400 400 400 400 500 630 630 630 A 63 63 80 80 80 100 100 125 125 160 160 160 200 200 200 250 250 250 250 315 315 400 400 400 500 500 630 630 A 50 50 63 63 80 80 80 100 100 125 160 160 200 200 200 200 250 250 250 250 315 315 400 400 400 500 500 630 A 50 63 63 80 125 125 160 200 200 250 315 400 500 500 630 A 35 50 63 63 100 125 125 160 200 250 315 400 400 500 500 S015005 000919 Permissible ratings and protection of PVC-insulated cables and wires acc. to supplement 1 to DIN VDE 0100 Part 430 Cable and wire system Method of installation No. of wires NYY, NYCWY, NYKY, NYM, NYMZ, NYMT, NYBUY, NHYRUZY NYM, MYBUY, NHYRUZY, NYIF, H07V-U, H07V-R, H07V-K, NYIFY A conduit-wired in heat insulating walls 2 3 B1 B2 C conduit-wired cables (or cable channel) inside or outside of walls or concealed E (single) core cable multi-core cables directly 2 2 2 3 3 open air 3 2 3 Recommended values for the permissible rating Iz of cables and wires with Cu-conductors and PVC-insulation, (operating temperature 70° C) at fixed installation in buildings, continuous operation, ambient temperature 25°C, correspondence of the rated current in In of overcurrent protective gear for protection at overload with high testing current Iz ≤ 1.45 In to E DIN VDE 0298 Part 4/1996 and DIN VDE 0100 Part 430 supplement 1/01.91 Cross section Cu-conductor in mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 Iz 16.5 21 28 36 49 65 85 105 126 160 193 223 In 16 20 25 35 40 63 80 100 125 160 160 200 Iz In Iz In Iz In 14 19 25 33 45 59 77 94 114 144 174 199 13 16 25 32 40 50 63 80 100 125 160 160 18.5 25 34 43 60 81 107 133 160 204 246 285 16 25 32 40 50 80 100 125 160 200 200 250 16.5 22 30 38 53 72 94 118 142 181 219 253 16 20 25 35 50 63 80 100 125 160 200 250 Iz 16.5 22 30 39 53 72 95 117 - In Iz In 16 15 13 20 20 20 25 28 25 35 35 35 50 50 50 63 65 63 80 82 80 100 101 100 - Iz In Iz 21 20 18,5 28 250 25 37 35 35 49 40 43 67 63 63 90 80 81 119 100 102 146 125 126 - In Iz In 16 25 35 40 63 80 100 125 - 21 29 39 51 70 94 125 154 - 20 25 35 50 63 80 125 125 - Iz 19,5 27 36 46 64 85 107 134 - In 16 25 35 40 63 80 100 125 - For underground laying of cables and wires and for cross sections > 120 mm2 in air, VDE 0298 Part 2 will apply. Adjustable protection devices (motor controllers, circuit breakers) have to be set to the rated operational current of the wire. Overcurrent protective gear for which the rated current In does not correspond to the values stipulated in the table, the next lower available rated current has to be selected. ϑu <> 30° C) acc. to E DIN 0298 Part 4/1996; Conversion factors for deviating ambient temperatures (ϑ applicable to the permissible rating Iz Insulating material Permissible operating temp. Ambient temperature °C 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 NR/SR 60° C PVC 70° C 1.29 1.22 1.15 1.08 1.00 0.91 0.82 0.71 0.58 0.41 - 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50 0.35 - EPR 80° C VPE 90 ° C 1.18 1.14 1.10 1.05 1.00 0.95 0.89 0.84 0.77 0.71 0.63 0.55 0.45 0.32 - 1.15 1.12 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71 0.65 0.58 0.50 0.41 0.29 Conversion factors NR/SR = natural rubber or soft rubber, PVC = polyvinyl chloride, EPR = ethylen-propylen-rubber, VPE = vulcanized polyethylene 1661 S015006 000731 Contactors for switching lamps and transformers Switching of lamps The table below specifies the number of incandescent and fluorescent lamps that can be switched with one contactor of each size. Similar tables for mercury-vapor, halogen, and sodium-vapor lamps will be provided on request. Rated Operacapacity tional current W A Rated voltage 50 Hz Compen- Permissible number of lamps per pole sation ENTRELEC-SCHIELE-contactor, open or enclosed type capacitor KL4 DL4K DL5K DL7K DL11K DL15K DL18K V µF 230 - DL22N DL30N DL42N DL65N DL90N DL 110 N Incandescent lamps 60 0.27 24 45 66 93 129 140 161 229 277 370 433 462 567 100 0.45 230 14 28 40 55 77 84 97 137 166 222 260 277 340 200 0.91 230 7 14 19 27 38 41 48 68 82 109 128 137 168 300 1.36 230 4 9 13 18 25 28 32 45 55 73 86 91 112 500 2.27 230 2 5 7 11 15 16 19 27 33 44 51 55 67 1000 4.5 230 1 2 4 5 7 8 9 13 16 22 26 27 34 2000 9.1 230 - 1 2 2 3 3 4 6 8 10 12 13 16 Electronic incandescent lamps (Dulux EL; Circolux EL,- SL- bzw. PL-lamps) 9/10 0.054 230 16 16 24 39 46 51 55 79 111 127 150 158 182 11 0.064 239 13 13 20 33 39 43 47 67 93 107 127 133 153 18 0.09 230 9 9 14 24 27 30 33 47 66 76 90 95 109 26 0.125 230 7 7 10 17 20 22 24 34 48 55 65 68 79 32 0.155 230 5 5 8 14 16 18 19 27 38 44 52 55 63 42 0.2 230 4 4 6 11 12 14 15 21 30 34 40 43 49 Fluorescent uncompensated Individual circuit 40 0.43 230 41 43 46 67 81 90 113 167 209 279 544 544 606 65 0.7 230 25 26 28 35 50 60 70 102 128 170 334 334 372 100 1.5 230 12 12 13 16 23 25 32 48 60 79 156 156 174 120 1.5 230 12 12 13 15 23 25 32 48 60 79 156 156 174 215 1.5 400 6 7 7.5 10 15 15 18 27 34 38 90 90 100 compensated 40 0.3 230 4.5 20 30 60 90 116 125 145 206 250 330 390 416 510 65 0.45 230 7 14 20 40 60 77 85 97 137 166 220 260 277 340 100 0.7 230 18 9 15 25 40 50 55 62 88 107 142 167 178 218 120 0.8 230 18.5 7 12 22 35 43 46 54 77 93 125 146 156 191 215 0.8 400 10 4 10 12 20 25 28 31 43 53 71 83 90 110 Double circuit by switching Number of double units 2 x 40 2 x 0.3 230 30 31 33 40 58 70 81 120 150 198 390 390 435 2 x 65 2 x 0.45 230 20 21 22 30 38 45 54 80 100 132 260 260 290 2 x 100 2 x 0.7 230 12 11 14 20 25 30 35 51 64 85 167 167 186 2 x 120 2 x 0.8 230 11 10 12 18 21 27 30 45 56 74 146 146 163 Switching of transformers (primary) The transient phenomena associated with the switching of transformers (primary) give rise to making current peaks that can be 20 to 30 times the rated currents. The table below specifies the making current peaks that the individual types of contactors are able to withstand. Types Rating at 400 V AC DL 4 K kW DL 5 K DL 7 K DL 11 K DL 15 K DL 18 K DL 22 N DL 30 N DL 42 N DL 65 N 4 5.5 7.5 11 15 18.5 22 30 42 63 Maximum making current peak (crest value) A 300 400 700 850 900 1000 1400 1700 2200 2600 Rated current of transformer up to 690 V ≈ Ie A 8 9 12 15 18 22 30 40 50 80 Single-phase transformer up to max. 440 V ~ Ie A 8 9 12 15 18 22 30 40 50 80 Notes The values given in the above tables are values for AC- and DC-operated contactors (economy circuit coils). Because of the switching behavior and the moved masses, no DL 4 K-DC...DL 5 K-DC contactors should be used in "DC" systems. DL 7 K-DC, DL 11 K-DC, DL 15 K-DC and DL 18 K-DC can be used as these contacts withstand electrical welding. Order reference : see contactors. When ordering, add voltage code number to order reference. Voltage codes: page 1654. Technical details: pages 1664-1665. 1662 S015007 000623 Standards Utilization categories for contactors to IEC 947-4-1, EN 60 947, DIN VDE 0660 Part 102 Nature of current Category Typical applications Alternating current AC 1 Non-inductive or slightly inductive loads, resistance furnaces AC 2 Starting of slip-ring motors AC 3 Starting squirrel-cage motors, switching off of motors while they are running AC 4 Starting squirrel-cage motors, inching, plugging, reversing DC-1 Non-inductive or slightly inductive loads, resistance furnaces DC-3 Shunt motors : Starting, plugging, reversing, inching, dynamic breaking DC-5 Series motors : Starting, plugging, reversing, inching, dynamic breaking DC-6 Switching of incandescent lamps Direct current Utilization categories for auxiliary contact blocks to IEC 947-5-1, EN 60 947, DIN VDE 0660 Part 200 Alternating current Direct current AC-12 Control of resistive load and solid-state loads with isolation by optocouplers AC-13 Control of solid-state loads with transformer isolation AC-14 (so far AC-11) Control of small electromagnetic loads (max. 72 VA) AC-15 (so far AC-11) Control of electromagnetic loads (higher than 72 VA) DC-12 (so far DC-11) Control of resistive load and solid-state loads with isolation by optocouplers DC-13 (so far DC-11) Control of electromagnets DC-14 (so far DC-11) Control of electromagnetic loads having economy resistors in circuit Degree of protection of electrical equipment by enclosures and covers acc. to IEC 529, DIN 40 050 1. Code No. Protection against accidental contact Protection against foreign bodies 2. Code No. Protection against water IP 00 No protection No protection No protection IP 20 Against ingress of fingers Against foreign bodies > 12 mm Ø No protection IP 41 Against ingress of tools and small wires Against foreign bodies > 1 mm Ø No damaging effect from dripping water IP 43 Against ingress of tools and small wires Against foreign bodies > 1 mm Ø No damaging effect from spraying water IP 54 Complete protection Against internal dust deposit No damaging effect from splash water IP 55 Complete protection Against internal dust deposit No damaging effect from water jets IP 65 Complete protection Dust-tight No damaging effect from water jets IP 67 Complete protection Dust-tight During immersion water should not penetrate in damaging amounts Notes Protection against accidental contacts acc. to IEC 536, DIN VDE 0106 Part 100 Design of electrical equipment and its arrangement in electrical installations with a rated operational voltage of up to 1000 V ~ and 1500 V ~ in respect to protection against direct contact, when operating elements (pushbuttons, toggle switches etc.) are close to hazardous parts. Contact protection "fingerproof" only refers to the operating element in the direction of operation. In this case, a distance from the operating element to hazardous parts in the radius of r = 30 mm from the central point has to be assured. The degree of protection IP 20 is more than contact protection "fingerproof." A protection against contacts with electrical equipment from all directions is included. On request, an extended protection against contact can be achieved for products with contact protection "fingerproof" and degree of protection IP 00, by using covers. 1663 S015008 000623 Technical details - mini contactors Technical details Types KL 2... KL 4... KLW 2... KLW 4... Rated insulation voltage Vi in V VDE 0110, group C IEC 947-1, BS 5424, NFC 20-040 CSA 22,2, Nr., 14 UL 508 Rated operational voltage Ve Rated operational current Ie on AC 1, UC ≤ 440 V ≤ 50° C A Rated thermal current Ith of auxiliary contacts at ≤ 50° C Permissible overcurrent ≤ 15 min / 3 min / 1 min A starting from cold at Θ ≤ 50° C 30 sec / 10 sec / 5 sec open types 0.5 sec / 1 sec AC 3 motor rating when 230 V switching slipring or squirrel cage 400 V motor on 500 V 50 Hz and 60 Hz, KL 2/Kl 4 690 V Max. rating related to S/h max. switching frequency Rated breaking capacity I eff 230...415 V IEC 947, NFC 63-110 500 V 690 V Rated making capacity I eff, IEC 947, NFC 63-100 Switching 1. Contactors 2. Control relays times Making : at Vc and - N/C opens after 20 ° C - N/O main pole closes - N/O closes after Breaking : - N/O main pole opens - N/O opens after - N/C closes after Voltage cutoff max. Switching frequency max. Mechanical life at Vc 50/60 Hz coils (millions operations) standard DC coil *) KL/KLW wide range DC coil Rated operating voltage Vc Voltage range operating limits (at ≤ 50° C) input coil drop-out value Power consumption of AC coil at Vc and 20° C inrush/hold Power consumption of DC coil inrush/hold Power dissipation of the coil Impedance per pole at Ith and 50 Hz Terminals capacities screw terminals solid conductor stranded conductor without wire end ferrule stranded conductor with wire end ferrule Faston connectors flat blade connector solder pin connection for p. c. b. main/control circuit unmistakable Tightening torque Philips no. 2 and dia, 6 Numbering of aux. contact blocks to EN 50005, EN 50012, EN 50011 Permissible ambient temperature operating storage Flame retardency Shock resistance in normal mounting position N/O / N/C vibration resistance 5...300 Hz Protective treatment to IEC 68/DIN 50 016 Altitude of site of installation without any derating Protection to VDE 0106 Minimum switching capacity Vmin (DIN 19 240) Imin Non-overlap distance to INRS, BIA Forced opening of contacts Short-circuit protection to IEC 947, VDE 0660, fuses class gL ≤ 440 Mounting position 1) V V V V Contactors 2.2...4 kW KLDC 2... KLWb 4... KLDC 4... KLWDC 2... KLWDC 4... Hi-Blocks Pn A A A A 1 ms ms 10...20 30...40 30...40 30...40 10...20 30 10 10...20 2 3.600 10/5*) 2 3.600 10/5*) 2 3.600 2 3.600 A A A kW kW kW kW ms ms ms S/h Control relays KH DC... KHi... KLi 4... 750 690 690 690 20 10 20/40/45 60/80/85 -/90 1.5/2.2 -/2.2 1.5/2.2 -/2.2 2.2/4 -/4 2.2/4 -/4 3/4 -/4 3/4 -/4 3/4 -/4 3/4 -/4 600 900 1200 100 % 75 % 50 % 110 110 110 110 80 80 80 80 70 70 70 70 110 110 110 110 1 1 1 2 690 10 90/80 2 110 2 5...15 10...20 25...35 30...40 25...35 30...40 10..20 15...25 2 10.000 10 10 15 2 10.000 10...20 15...25 2 6.000 10/5*) V 20 30 30 ~12...690 ~24...230 .... 12...250 .... 12..72 ~12...690 ....12...250 .... 12...72 0.8...1.15 Vc 0.85...1.1 Vc 0.8...1.15 Vc 0.7...1.30 Vc 0.8...1.15 Vc 0.8...1.15 Vc 0.7...1.30 Vc ≥ 0.20 Vc ≥ 0.10 Vc ≥ 0.10 Vc ≥ 0.10 Vc ≥ 0.20 Vc ≥ 0.10 Vc ≥ 0.10 Vc VA 30/4.5 3/3 1.3 3 30/4.5 W W mΩ mm2 mm2 mm2 mm2 Nm °C °C g m V mA mm V 3/3 3 1.8/1.8 1.8 3 Max. 2x4 2x4 1x1.5+1x2.5 1x1.5+1x2.5 Min. 1x1.5 1x0.75 1x0.34 1x0.34 4minx35µ 1.3 3/3 3 1.8/1.8 1.8 Max. to IEC 1x4+1x2.5 2x2.5 1x1.5+1x2.5 1x1.5+1x2.5 0.8 up to 5 aux. contact blocks 0.8 up to 8 aux. contact blocks -25 ... +50 -50 ... +80 to UL 94, class V-1, self-extinguishing 10/15 g 2/4 g TC, climatic proof 2000 max. finger proof 17 5 0.5 yes 25 A 10 A Min. operational voltage: 0.85 x VC without restriction 1664 KH S... 1) 1) S015009 000623 Technical details - contact life of KL 2... and KL 4... mini contactors Selection of contactors for particular applications KL 2 ... KL 4 ... Utilization category AC-1 Switching resistive loads (cos ϕ ≥ 0.95). On AC-1 the breaking current Ia normally equals the rated operational current Ie Example : Ve = 220 V Ie = 10 A on AC-1 Θ = 40° C Ia = Ie = 10 A Electrical life taken from the curve opposite: 500.000 operations. million operations (Ve ≤ 440 V) Utilization category AC-3 Example : Asynchronous motor P = 2.2 kW Ve = 400 V Ie = 4.8 A Ia = Ie = 4.8 A KL 2 ... KL 4 ... million operations (Ve ≤ 440 V) Switching squirrel-cage motors. Switching off during running. The breaking current Ia equals the motor rated current. No. of operations required : 1,000,000 Contactors size to be chosen according to the curve opposite: KL 2 ... breaking current A Utilization category AC-4 (Ve ≤ 440 V) KL 2 ... KL 4 ... Example : Asynchronous motor P = 2.2 kW Ve = 400 V Ie = 4.8 A Ia = 6 x Ie = 28.8 A million operations Switching squirrel-cage motors. Switching off during start of motor. On AC 4 the breaking current Ia is 6 times the motor rated current Ie. No. of operations required : 40,000 Contactor size to be chosen according to the curve opposite: KL 2 ... Utilization category AC-1 Max. rated operational current related to duty Duty % 90 % 60 % 30 % and switching frequency. 300 ops/hr Amp. 13 15 18 120 ops/hr Amp. 15 18 19 30 ops/hr 19 20 20 (Ve ≤ 440 V) Additional information Increasing the rated current by paralleling main poles Amp. Amp. Multiply the above rated currents by the following coefficients (K) which take into account the often unbalanced current distribution between poles. 2 poles in parallel K = 1.60 3 poles in parallel K = 2.025 1665 S015010 000623 Technical details - contact life of KH ... mini control relays Ratings of auxiliary contacts AC voltage (utilization category AC-15) DC voltage (utilization category DC-13) to IEC 947 Electrical life (up to 3.600 ops/hr) at inductive load in circuits with magnetic drives : making capacity (cos ϕ 0.7) = 10 times the breaking capacity (cos ϕ 0.4). Electrical life (up to 1.200 ops/hr) at inductive load in circuits with magnetic drives, without economy resistor, time constant of which increases with rating. at operations ... *) 1 x 106 operations 3 x 106 operations 10 x 106 operations Making capacity for occasional switching *) V VA VA VA VA 24 48 17 7 1000 48 96 34 14 2050 110/ 127 240 86 36 5000 220/ 230 440 158 66 10000 440 880 317 132 13000 600/ 690 1200 500 200 9000 V W W W W 24 120 55 15 720 48 80 38 11 600 110 60 30 9 400 220 52 28 8 300 Electrical life of contacts Breaking capacity (VA) 1 Max. duty of aux. contacts: 50 operations max. at intervals of 10 secs (breaking capacity = making capacity x cos ϕ 0.7) 2 Electrical life of aux. contacts for : - 1 million operations (2 a) - 3 million operations (2 b) - 10 million operations (2 c) Additional technical details - page 1664 1666 380/ 400 800 288 120 14000 Breaking capacity (W) 3 Max. duty of aux. contacts: 20 operations max. at intervals of 10 secs and current flow time of 0.5 secs per operation 4 Thermal limit Ith 440 51 26 7 230 600 50 25 6 200 S015011 000919 Technical details - contactors 4...18.5 kW / 5...25 HP at 460 V, 3 ph. / AC 3 Technical details Types Rated insulation voltage Vi VDE 0110 IEC 947-1, EN 60 947, VDE 0660 CSA 22,2, no. 14, UL 508 Rated operating voltage VC minimum/maximum Permissible range of operating voltage Vc Rated operational current Ie on AC 1/AC 3 ≤ 40° C Rated thermal current Ith/Ithe open/enclosed 55°C Permissible overcurrent 3 min / 1 min at overload time of 10 secs / 5 secs (open type) 2 secs / 1 secs Three-phase power when switching resistive load open/enclosed on AC 1 at 400 V Motor rating when switching 230 V slipring (on AC2) or squirrel cage 400 V (on AC3) motors 500 V at 50/60 Hz 690 V Rated breaking capacity 415 V at cos ϕ = 0.35 500 V 690 V Rated making capacity at cos ϕ = 0.35 Switching times at 20° C Making: - N/O closes after AC Breaking: - N/O opens after Making: A = economy circuit coil - N/O closes after DC B = true DC coil at Breaking: -15/+10 % Vc - N/O opens after Switching times for direct change over of reversing and star-delta contactors (at 110 % Vc) Power consumption of AC coil inrush/hold of DC coil (economy circuit coil) inrush/hold of DC coil (true DC coil) inrush/hold Impedance per pole Power dissipation per pole at Ith Switching frequency - no load operations/hour AC/DC coil contactor without overload relay on AC 1 on AC 2 on AC 3 on AC 4 Mechanical life no. of operations Electrical life of contacts Permissible ambient operating temperature range storage Size of connecting screws/tightening torque - main terminals Terminal capacities - main and aux. terminals Mounting position to DIN 40 046 IEC 68 Shock resistance, normal mounting position, half sine shock shock duration 20 ms N/O / N/C Climatic conditions Weight Rated operational current Ie 230/400 for auxiliary contacts on AC 15 duty 500/690 Rated thermal current of auxiliary switches Ith/Ithe Rated insulation voltage of auxiliary switches to VDE 0110 V Short-circuit protection of contactor without thermal relay type 1 or 22) Short-circuit protection of auxiliary switches fuse gL/gI Safety isolation DL 4 K DL 4 K-DC V V V V 750 690 600 12/690 A A A A A kW 22/9 22/16 70/80 110/120 160/180 13/10 kW kW kW kW A A A A 2.2 4 5.5 4 90 90 50 300 DL 5 K DL 5 K-DC DL 7 K DL 7 K-DC 750 690 600 12/690 750 690 600 12/690 0.8...1.1 25/12 39/16 25/20 39/25 70/80 70/80 110/120 220/280 160/180 350/400 16/13 21/16 3 5.5 7.5 5.5 120 120 70 300 4 7.5 11 7.5 220 220 130 600 DL 11 K DL 15 K DL 11 K-DC DL 15 K-DC DL 18 K DL 18 K-DC 750 690 600 12/690 750 690 600 12/690 750 690 600 12/690 39/23 39/30 70/80 220/280 350/400 26/20 54/30 54/45 120/260 300/450 550/700 36/36 54/37 54/50 120/260 300/450 550/700 36/36 5.5 11.0 15.0 11.0 220 220 130 600 9 15 18.5 15 450 350 250 700 11 18.5 20 18.5 450 350 250 700 ms 12...30 11...20 ms 10...20 5...20 ms ms ms VA W W mΩ W A 20...30 / B 65...85 A 10...16 / B 13...14 15...20 15...20 15...20 95/10 95/10 105/1 105/1 6.5 6.5 1.5 1.5 2.5 2.5 10000/1500 A 15...30 / B 65...85 95/10 95/10 105/1 105/1 8.5 8.5 1.5 1.5 2.5 2.5 5000/1500 1500 1000 1000 °C °C Nm1) mm 2 g kg A A A 690 A A M3.5/1.8 M3.5/1.8 0.4 6/4 2/1 16 690 25/20 16 95/10 95/10 105/1 105/1 8.5 8.5 1 1 2 2 3000/1500 750 750 250 10 million see diagram page 1672 -25° C ... +55° C -50° C ... +80° C M3.5/1.8 M3.5/1.8 6/2.5 6/2.5 6/2.5 vertical mounting plane ± 22.5° 6/4 A 10...30 / B 13...18 10...15 10...15 15..20 6/2.5 M3.5/1.8 25/2.5 6/4 6/4 6/4 6/humid warmth, constant, acc. to DIN IEC 68 Part 2-3 humid warmth, cyclic, acc. to DIN IEC 68 Part 2-30 0.4 0.4 0.4 0.62 6/4 6/4 6/4 2/1 2/1 2/1 16 16 16 690 690 25/20 50/35 50/35 100/63 16 16 16 up to 400 V AC to DIN VDE 0106 Part 101 and A1 (draft 2/89) between coil and contact M4/3 caged terminals 25/2.5 6/- 0.62 100/63 - Notes 1) Screws for compact contactors Phillips H2 2) Short-circuit withstand of contactor without overload relay corresponding to type 2 coordination (No damage to device, except light welding of contacts). 1667 S015012 000731 Technical details - contactors 22...270 kW / 30...400 HP at 460 V, 3 ph. / AC 3 Technical details Types Rated insulation voltage Vi VDE 0110 IEC 947-1, EN 60 947, VDE 0660 CSA 22,2, Nr. 14 UL 508 minimum/maximum Rated operating voltage VC Permissible range of operating voltage Vc Rated operational current Ie on AC 1/AC 3 ≤ 40° C Rated thermal current Ith/Ithe open/enclosed 55°C Permissible overcurrent 3 min / 1 min at overload time of 10 secs / 5 secs (open type) 2 secs / 1 secs Three-phase power when switching resistive load open/enclosed on AC 1 at 400 V Motor rating when switching slipring 230 V (on AC2) or squirrel cage 400 V (on AC3) motors 500 V at 50/60 Hz 690 V Rated breaking capacity 415 V at cos ϕ 0.35 500 V 690 V Rated making capacity at cos ϕ = 0,35 Switching times at 20° C Making: - N/O closes after AC Breaking: - N/O opens after Making: A = economy circuit coil - N/O closes after DC Breaking: B = true DC coil at -15/+10 % - N/O opens after Switching times for direct change over of reversing and star-delta contactors (at 110 % Vc) Power consumption of AC coil inrush/hold economy circuit coil true DC coil Impedance per pole Power dissipation per pole Ith Switching frequency - no load operations/hour AC/DC coil contactor without overload relay to AC 1 to AC 2 to AC 3 to AC 4 Mechanical life no. of operations Electrical life of contacts Permissible ambient operating temperature range storage Size of connecting screws/tightening torque - main terminals Terminal capacities - main and aux. terminals Mounting position to DIN 40 046 IEC 68 Shock resistance, normal mounting position, half sine shock, shock duration 20 ms N/O /N/C Climatic conditions V V V V DL22N DL30N DL42N DL65N DL90N DL110N 750 750 690 690 600 600 12/660 12/660 750 690 600 12/660 750 690 600 12/660 750 750 690 690 600 600 12/660 24/660 0.8...1.1 260/170 290/205 260/230 290/260 600/800 750/1250 1600/1700 1500/1900 1800/2000 2000/2300 191/171 191/171 A 80/44 100/60 130/79 230/119 A 80/75 100/90 130/115 230/200 300/500 500/700 A 200/300 300/500 A 500/600 1000/1200 1000/1200 1300/1500 A 800/1000 1400/1600 1400/1600 1700/1900 kW 53/50 66/59 86/76 171/151 DL132N DL165N 750 750 600 24/660 360/245 360/315 750/1500 2000/2300 2600/2900 237/207 1000 1000 600 80/660 DL245N DL270N 1000 750 600 80/660 750 690 600 80/660 380/295 500/460 380/340 500/460 1000/1600 2000/2200 2500/3000 3000/3400 3200/3500 3600/4000 250/224 329/303 600/499 600/540 2500/2800 4000/4600 5000/5500 395/355 kW kW kW kW A A A A 12.5 22 30 30 450 440 330 1000 18.5 30 37 37 800 730 670 1600 22 40 50 55 1000 900 700 1600 37 63 75 75 1200 1200 800 1900 50 90 110 110 1400 1300 1100 2000 60 110 132 160 1700 1600 1500 2300 75 132 160 180 2100 2100 2100 2900 90 160 180 180 2400 2100 2100 3500 115 250 250 270 3700 3100 3100 4000 160 270 345 270 4000 4000 2400 5500 ms 14-19 14-19 11-28 12-20 12-20 12-25 12-25 20-60 20-60 35-110 ms 16-20 16-20 10-15 10-17 10-17 12-18 12-18 20-35 20-35 35-55 ms 10-20 10-20 20-40 20-30 20-30 35-55 35-55 35-65 35-56 50-60 ms ms 12-18 14-18 12-18 14-18 7-12 11-16 10-14 10-15 10-14 10-15 10-18 21-25 10-18 21-25 18-28 26-33 18-28 26-33 30-60 58-83 430/44 280/6 0.46 31.1 950/77 400/9 0.45 37.9 950/77 1750/88 400/9 1150/11 0.28 0.2 36.3 28.9 2000/1200 VA 146/22 146/22 W 220/2 220/2 W mΩ 0.8 0.5 W 5.1 5 336/44 430/44 260/6 280/6 0.6 0.46 10.2 31.1 3000/1500 750 750 1000 500 500 250 10 million see diagram page 1672 -25° C ... +55° C -50° C ... +80° C M10 M10 M10 M 12 °C °C Nm4) M5/3,5 caged term. 2 mm 35 M6/4 caged term. 35 M6/4 caged term. 35 g 5.5/4 6.5/5.5 5/4 4.5/3.5 4/3 4/3 5/3 humid warmth, constant, acc. to DIN IEC 68 Part 2-3 humid warmth, cyclic, acc. to DIN IEC 68 Part 2-30 2.1 3.2 3.2 9.0 9.0 18 10/6 10/6 10/6 10/6 10/6 10/6 4/2 4/2 4/2 4/2 4/2 4/2 16 16 16 16 16 16 690 690 690 750 750 750 200/160 250/224 315/250 400/355 500/355 630/500 16 16 16 16 16 16 5.5/4 Weight kg 1.2 1.3 230/400 A 10/6 10/6 Rated operational current Ie for auxiliary contacts on AC 15 duty 500/690 A 4/2 4/2 A 16 16 Rated thermal current of auxiliary switches Ith /Ithe Rated insulation voltage of auxiliary VDE 0110 V 690 690 Short-circuit protection of contactor without thermal relay type 1 or 2 3) A 125/100 125/100 Short-circuit protection of auxiliary switches fuse gL/gI A 16 16 Capacitor contactor on request 120 120 185 185 vertical mounting plane ± 22.5° 1750/88 2500/132 1150/11 1150/11 0.2 0.15 50 54 M12 M12 185 2x150 1) M12 2x185 2) 5/3 18 30 10/6 10/6 4/2 4/2 16 16 750 750 800/630 800/630 16 16 Notes 1) Also suitable for 2 x 30 x 5 mm 2) Also suitable for 2 x 40 x 5 mm 3) Short-circuit withstand of contactor without overload relay corresponding to type 2 coordination (No damage to device, except light welding of contacts). 4) Slotted screwdriver up to DL 42 N 1668 3.5/3 S015013 000623 Technical details - K range contactors DLg..., DC switching AC/DC operated (economy circuit coil) Technical details Rated insulation voltage Vi Rated thermal current Rated operational current Ie with series wiring of main contacts Types Ith Ithe on DC 1 (L/R ≤ 15 ms) circuit diagram on DC 3 + DC 5 Permissible DC load up to 60 V DC, L/R ≤ 5 ms, single pole version2) Power consumption (economy circuit coil)1) Permissible range of operating voltage Vc Minimum and maximum rated operating voltages Switching times at 20° C Making: - N/O closes AC Breaking: - N/O opens Making: - N/O closes (economy circuit coil) DC Breaking: - N/O opens Rated thermal current for auxiliary contact Ith/Ithe Rated operational current Ie on DC 13 at on DC 12 at resistive load Maximum cable size for auxiliary contacts Short-circuit protection of auxiliary switches gL DLg 4 K DLg 5 K DLg 7 K DLg 11 K DLg 15 K DLg 18 K 900 39 30 39 39 39 39 39 8 60 open enclosed 24 V 110 V 220 V 24 V 110 V 220 V V A A A A A A A A A 900 22 16 22 22 22 22 22 6 40 900 25 20 25 25 25 25 25 6 40 900 39 25 32 32 32 32 32 8 60 900 54 45 54 54 54 54 54 10 100 900 54 50 54 54 54 54 54 16 100 inrush hold W W 105 1 105 1 105 1 minimum maximum V V 12 220 12 220 105 105 105 1 1 1 0.8...1.25 DC / 0.8...1.1 AC 12 12 12 220 220 220 after ms 12...30 11...20 after ms 10...20 5...20 after ms 20...30 15...30 after ms A A A A A A A mm2 A 24 V 110 V 220 V 24 V 110 V 220 V 10...16 16 10 2 0.75 10 6 1 2.5 16 16 10 2 0.75 10 6 1 2.5 16 12 220 10...30 16 10 2 0.75 10 6 1 2.5 16 16 10 2 0.75 10 6 1 2.5 16 - - Notes 1) Power consumption of AC and true DC coils see page 1667. 2) Main contacts connected parallel, see accessories on page 1614. 1669 S015014 000623 Technical details - contactors DLg..., DC switching AC/DC operated (economy circuit coil) Technical details Rated insulation voltage Vi Rated thermal current Types Ith Ithe on DC 1 open enclosed 24 V Rated operational current Ie with series wiring of main contacts 110 V 220 V (L/R ≤ 15 ms) 24 V circuit on 110 V diagram DC 3 + DC 5 220 V Permissible DC load up to 60 V DC, L/R ≤ 5 ms, single pole version2) Terminal capacities - Main terminals at single pole switching Power consumption (economy circuit coil)1) inrush hold Permissible range of operating voltage Vc Minimum and maximum rated min. operating voltages max. Switching times at 20° C Making: - N/O closes after AC Breaking: - N/O opens after Making: - N/O closes after (economy circuit coil) DC Breaking: - N/O opens after Rated thermal current for auxiliary contact Ith/Ithe A Rated operational current Ie on DC 13 at 24 V 110 V 220 V on DC 12 at 24 V resistive 0110 V load 220 V Maximum cable size for auxiliary contacts Short-circuit protection of auxiliary switches gL DLg22N DLg32N DLg42N DLg65N DLg90N DLg110N DLg132N DLg165N DLg245N DLg270N V A A A A A A A A A 900 80 75 75 75 75 75 75 12 160 900 100 90 90 90 90 90 90 25 200 900 130 115 115 115 115 115 115 60 240 900 230 200 200 200 200 200 200 90 360 900 260 230 230 230 230 230 230 150 460 900 290 260 260 260 260 260 260 200 500 900 360 315 315 315 315 315 315 200 - 1200 380 340 340 340 340 340 340 250 - 1200 500 460 460 460 460 460 460 300 - 1200 600 540 540 540 540 540 540 350 - mm 2 70 95 95 150 150 240 - - - - W W 186 8 260 6 260 6 280 6 1150 11 1150 11 1320 11 V V 12 220 12 220 12 220 42 220 42 220 42 220 ms 14-19 11-16 11-28 12-20 12-20 12-25 12-25 20-60 20-60 35-110 ms 16-20 10-15 10-15 10-17 10-17 12-18 12-18 20-35 20-35 35-55 ms 10-20 20-40 20-40 20-30 20-30 35-55 35-55 35-65 35-65 50-60 ms 12-18 16 16 A 10 A 5 A 1 A 10 A 6 A 1 mm2 4 A 16 7-12 16 10 5 1 10 8 1 4 16 7-12 16 10 5 1 10 8 1 4 16 10-14 16 10 5 1 16 8 2 4 16 10-14 16 10 5 1 10 6 2 4 16 10-18 16 10 5 1 16 8 2 4 16 10-18 16 10 5 1 16 8 2 4 16 18-28 16 10 5 1 16 8 2 4 16 18-28 16 10 5 1 16 8 2 4 16 30-60 Notes 1) Power consumption of AC coils - page 1668 2) Main contacts connected parallel, see accessories on page 1623. 1670 280 400 400 6 9 9 0.8...1.1 Vc (from warm) 12 12 24 24 220 220 220 220 10 5 1 16 8 2 4 16 S015015 000623 Technical details - control relays and auxiliary contact blocks Technical details Types Rated insulation voltage Vi B A True DC coil Economy circuit coil HL 4 K HL 4 K DCHL 8 KHL 8 K DC- VDE 0110 CSA/UL IEC 337-1, 947-1 Permissible ambient temperature operating/storage Power consumption of AC coil inrush/hold Power consumption of DC coil inrush/hold (economy circuit coil) Power consumption of DC coil inrush/hold (true DC coil) Operating limits of magnet coil Vc V V V °C VA W 750 600 ac. 690 W 6.5 Rated thermal current Ith/Ithe Mechanical life to VDE group E 1 at 3000 ops/hr Switching frequency A ops 65/9 HLg 4 K- Auxiliary contact blocks Hi, Li / S 11, S 20 750 600 ac. 690 -25°C ... to + 55°C / -50°C to +80°C 115/1 750 600 ac. 690 - AC 0.8...1.1 DC 0.8...1.25 2.5 2.5 2.5 Terminal capacities (solid, stranded conductor) mm 2 Connecting screw / tightening torque Nm M3.5/1.2 M3.5/1.2 M3.5/1.1 Shock resistance (half-sine wave, shock duration 20 ms) N/O / N/C g 6 6 6 Switching times at 20°C Making: - N/C opens after ms 7...14 7...14 - N/O closes after ms 10...23 10...23 12...30 AC coils Breaking: - N/O opens after ms 16...35 16...35 10...20 - N/C closes after ms 17...38 Making: Vnom: -15% ......... +10%1 67 ......... 50 A = economy circuit coil - N/C opens after ms 7...14 85 ......... 65 - N/O closes after ms 10...23 A 20...30 DC coils B = true DC coil Breaking: Vnom: -15% ......... +10% 13 ......... 14 at -15 / +10 % - N/O opens after 16...35 A 10...16 25 ......... 22 - N/C closes after ms 17...38 Mounting position to DIN 40 046 IEC 68 vertical mounting plane ± 22.5° ± 22.5° ± 22.5° Climatic conditions Control relays are climatic proof to IEC 68, Part 2-3, Part 2-30 Rated operating voltage Vc V 12...660 12...660 12...660 V Rated operational current Ie AC voltage 230 V A 6 6 6 on AC 15 400 V A 4 4 4 500 V A 2 2 2 690 V A 1 1 1 DC voltage 24 V A 10 10 10 on DC 13 110 V A 2 2 2 L/R = 15 ms 220 V A 0.75 0.75 0.75 resistive load 24 V A 10 10 10 on DC 12 110 V A 6 6 4 L/R=<1ms 220 V A 1 1 1 operations at nominal rating ops/ on AC 15 / DC 13 hr no-load operations AC/DC ops/hr Short-circuit protection slow type gL A Safety isolation of coil and contacts to VDE 0106 Part 101 and A1 (draft 2/89) 16 3x107 16 3x107 10/16 3x107 1200 1200 1200 10000/1500 16 10000/1500 16 10000 16 Note: 1Nominal coil voltage -15% to +10% 1671 S015016D 000623 Technical details - contact life Electrical life on AC 2 to AC 4 VDE 0660, Part 102 Applicable to contactor types DL 4 K to DL 270 N Typical values: Electrical life of a contactor is determined, to a large extent, by the breaking current of the load. The characteristic curves, opposite, represent electrical life in relation to the breaking current. Up to 6 times the starting and breaking current should be taken into account when selecting a contactor (see example). Example: DL 22 N Three-phase motor 22 kW rated operational current 44 A = max. breaking current on AC 3 Electrical life 106 operations Three-phase motor 22 kW 6 times rated operational current 6 x 44 A = 264 A = max. breaking current on AC 4 Electrical life 5 x 104 operations PN = Electrical life Utilization category 100 % AC 1 - VDE 0660, Part 102-4.3.6 switching resistive loads (cos ϕ 0.95) e.g., resistance furnaces Max. AC 1 ratings for enclosed contactors have to be reduced as follows: DL 4 K / DL 5 K DL 22 N to DL 110 N DL 132 N DL 165 N to DL 270 N 1672 75 90 85 90 % % % % Rating of 3-phase squirrel cage motor IA = Breaking current Ie = Rated operational current S015017 000919 Dimensions - KH / KL, KLW and accessories KH... control relays with HS / HF aux. contact block attached Base mount To 35 mm mounting rail (DIN 50 022) HV-48, HV-240 timer modules KL 2, KL 4... contactors with HS, HF, LS aux. contact block attached KLW 2, KLW 4... reversing contactors with HS, HF, LS aux. contact block attached Base mount To 35 mm mounting rail (AM 1-DP 200 or AM 1-DE 200) DIN 50 022 To 35 mm mounting rail (AM 1-DP 200 or AM 1-DE 200) DIN 50 022 Mounting on printed circuit board Mounting reversing contactors or 2 contactors side by side on printed circuit board 1673 S015018 000919 Dimensions - HL 4 K / HLg 4 K / HL 8 K / DL 4 K...DL 18 K... reversing and star-delta contactors AC-version or DC-version with economy circuit coil HL 4 K control relay HLg 4 K control relay HL 8 K control relay (HL 4 K + aux. contact: H = 120 mm) Dimension H : 120 mm with aux. contact 125 mm with latch head 137 mm with timer 127 mm with aux. contact with plunger Contactors DL 4 K...-DL 11 K, DLg 4 K..-DLg 11 K, DLW 4 K...DLW 18 K, with M 23 K thermal relay attached Dimension H : 120 mm with aux. contact 125 mm with latch head 137 mm with timer 127 mm with aux. contact with plunger Dimension B : with 2 side mounted aux. contact blocks = 68+1 Dimension L : with relay interface module RM-K Contactors DL 15 K...DL 18 K, DLg 15 K...DLg 18 K, star-delta contactors DLDAe 7,5 K...DLDAe 30 K, with M 40 K thermal relay attached Type : Dimension H : 132 mm with aux. contact 139 mm with latch head 150 mm with timer 139 mm with aux. contact with plunger 1674 Dimension B : with 2 side mounted aux. contact blocks = 68+1 Dimension L : with relay interface module RM-K DLDAe 7.5 K 12.5 K 15 K 18.5 K 22 K 30 K supply voltage 4K 7K 7K 15 K 15 K 15 K ∆ 4K 7K 7K 11 K 15 K 15 K Y 4K 4K 5K 7K 7K 11 K S015019 000623 Dimensions - DL 4 K DC...DL 18 K DC, HL 4 K DC DL 4 K DC..., DL 11 K DC... + M 23 K HL 4 K DC, HL 8 K DC Dimension H : 159 mm with aux. contact 166 mm with aux. contact with plunger 166 mm with latch head 177 mm with timer with module = 106 mm high DL 15 K DC / DL 18 K DC + M 40 K Dimension H : 171 mm with aux. contact 178 mm with aux. contact with plunger 178 mm with latch head 189 mm with timer with module = 106 mm high 1675 S015020 000731 Dimensions - DL 22 N...DL 42 N, DLDAe 37 N...DLDAe 65 N, DLW 22 N...DLW 42 N 2 1 3 Single contactors 1 Reversing contactors 2 DL 22 N + M 80 N Star-delta contactors 3 Supply voltage ∆ Y DLDAe 37 N + M 80 N DL 22 N DL 22 N DL 15 K DLg 22 N + M 80 N DLW 22 N + M 80 N DLDAe 45 N + M 80 N DL 22 N DL 22 N DL 18 K DL 30 N + M 80 N DLW 30 N + M 80 N DLDAe 55 N + M 80 N DL 30 N DL 30 N DL 18 K 1 2 3 Single contactors 1 Reversing contactors 2 Star-delta contactors 3 A Supply voltage ∆ Y DLW 42 N + M 80 N DLDAe 65 N + M 80 N 99 DL 42 N DL 42 N DL 22 N DL 42 N + M 80 N DLg42 N + M 80 N 1676 S015021 000623 Dimensions - DL 65 N, DL 110 N, DLDAe 110 N...250 N, DLW 65 N...DL 90 N 2 1 3 Single contactors 1 Reversing contactors 2 DL 65 N + M-b 177 S, DL 90 N + M-b 177 S DLW 65 N + M-b 177 S DLg 65 N + M-b 177 S, DLg 90 N + M-b 177 S Star-delta contactors 3 Supply voltage ∆ Y A B C D E DLDAe 75 N 65 N 32 N 22 N 118 99 - - - DLDAe 110 N 65 N 65 N 42 N 127 118 - - - DLDAe 160 N 90 N 90 N 65 N 128 127 62 M 12 37 + M-b 177 S Dimensions 2 1 Single contactors 1 Star-delta contactors 2 Supply voltage ∆ Y DL 110 N + M-bw 207 DLDAe 200 N + M-bw 320 S DL 110 N DL 110 N DL 65 N DL 132 N + M-b 177 S + M-bw 320 S DLDAe 250 N + M-bw 320 S DL 132 N DL 132 N DL65 N 1677 S015022 000623 Dimensions - DL 165 N...270 N, DLDAe 360 N...500 N 2 1 Single contactors 1 Star-delta contactors 2 Supply voltage ∆ Y DL 165 N + M-b 177 S, DL 165 N + M-bw 320 S DLDAe 360 N + M-b 721 Sw DL 245 N DL 245 N DL 110 N DL 245 N + M-b 721 Sw DLg 165 N, DLg 245 N 1 2 Single contactors 1 Star-delta contactors 2 Supply voltage ∆ Y DL 270 N + M-b 721 Sw, DL 270 N + M-bw 320 S DLDAe 500 N + M-b 721 Sw DL 270 N DL 270 N DL 165 N DL 270 N 1678