Mini contactors • control relays, contactors, reversing

Transcription

Mini contactors • control relays, contactors, reversing
S014003
000623
Mini contactors • control relays, contactors, reversing contactors
Mini contactors
... the benefits at a glance ...
4 basic coil versions
✓ AC : 4.5 VA
DC : 2.4 W
DC : 1.5 W
✓ AC with rectifier : 3.5 VA
(hum-free, silent, no peak currents
on make, insensitive to short
voltage cutoffs).
✓
✓
✓
✓
✓
✓
M 06 motor protection relay
covering a range from 0.1 to 11.5 A
Phase failure sensitive
Electrically separate 1 N/O + 1N/C
contacts
Hand/auto reset
Reset and setting parameters can
be protected by sealable cover
Control terminals are prewired
Relay can be mounted beneath
contactor
KH ... CONTROL RELAY
KL ..., KLW ... CONTACTORS
PLUS SYSTEM COMPONENTS
Control relay
Versions : Screw terminals, Faston
connectors or solder pins
AC, DC, interface or
hum-free coils
Contactors
Thermal overload relay
Auxiliary contact block 2 or 4 pole
Versions : Screw or Faston
connection for top mounting
Timer module
Delay on energization 1 to 30 secs
Versions : 24 to 48 V AC/DC
110 to 240 V AC
front mounting
Coil suppressor
Versions : RC, varistor or diode
front mounting
Reversing contactor
Versions : Screw terminals, Faston connectors
or solder pins AC, DC,
interface or hum-free coils
Broad coil voltage range ensures reliable operation
Integral or external coil suppressors give reliable protection
to electronics
2- or 4-pole snap-on auxiliary contact blocks to increase the
number or contacts
Compact size saves space
Separation of contacts ensured by forced opening of
contacts
Maximum shock resistance through specially designed
magnetic system
Contact reliability through special contacts
Safe transmission of low-level signals
Improved life at AC 3/AC 4 duty through optimized arc chutes
and contact materials
Suitable for resistive loads (AC 1): contacts are designed for Ith
= 29 A at 50°C
1635
S014004
000919
Control relays KH ...,
AC operated
without integral coil suppressor
Terminal numbering to DIN EN 50 011
Compact design
Available in 3 versions :
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency coils 50/60 Hz
High contact reliability
Forced opening of contacts
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals :
Further notes at the bottom of this page.
Characteristics of control relays KH ..., AC operated, 4.5 VA coils
Version with screw terminals
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHS-31
1 309 060 ..
3
1
KHS-22
1 309 070 ..
2
2
KHS-40
1 309 050 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
Weight
kg
For dimensions
see page 1673
0.180
- 50/60 Hz coil
- without integral
coil suppressor
0.180
0.180
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHF-31
1 309 160 ..
3
1
KHF-22
1 309 170 ..
2
2
KHF-40
1 309 150 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
Weight
kg
For dimensions
see page 1673
0.180
- 50/60 Hz coil
- without integral
coil suppressor
0.180
0.180
Version with solder pins, 1.7 mm Ø, hole on p. c. b.
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHL-31
1 309 260 ..
3
1
KHL-22
1 309 270 ..
2
2
KHL-40
1 309 250 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
0.210
- 50/60 Hz coil
- without integral
coil suppressor
1)
1636
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
0.210
0.210
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
Weight
kg
Auxiliary contact block - page 1641
Other system components - page 1641
Technical details - pages 1664, 1666
For dimensions
see page 1673
S014005
000919
Control relays KH ...,
AC operated
with integral coil suppressor
Terminal numbering to DIN EN 50 011
Compact design
Available in 3 versions :
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency coils 50/60 Hz
High contact reliability
Forced opening of contacts
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for control relays KH ..., AC operated, 4.5 VA coils
Version with screw terminals
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHS-31
1 309 062 ..
3
1
KHS-22
1 309 072 ..
2
2
KHS-40
1 309 052 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
- with integral
coil suppressor
Weight
kg
For dimensions
see page 1673
0.180
0.180
- permitted up to
240 V max.
0.180
Features
Weight
kg
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHF-31
1 309 162 ..
3
1
KHF-22
1 309 172 ..
2
2
KHF-40
1 309 152 ..
4
0
Circuit diagram to
DIN EN 50 011
- with integral
coil suppressor
For dimensions
see page 1673
0.180
0.180
- permitted up to
240 V max.
0.180
Features
Weight
kg
Version with solder pins, 1.7 mm Ø, hole on p. c. b.
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHL-31
1 309 262 ..
3
1
KHL-22
1 309 272 ..
2
2
KHL-40
1 309 252 ..
4
0
Circuit diagram to
DIN EN 50 011
- with integral
coil suppressor
For dimensions
see page 1673
0.210
0.210
- permitted up to
240 V max.
0.210
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
AC-coils available with integral coil suppressor to max. 230 V
1)
Auxiliary contact block - page 1641
Other system components - page 1641
Technical details - pages 1664, 1666
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
1637
S014006
000919
Control relays KHDC ...,
DC operated
without integral coil suppressor
Terminal numbering to DIN EN 50 011
Compact design
Available in 3 versions :
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Forced opening of contacts
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
Further notes at the bottom of this page.
Approvals:
Characteristics for control relays KHDC ..., DC operated, 3 W coils
Versions with screw terminals
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCS-31
1 309 065 ..
3
1
KHDCS-22
1 309 075 ..
2
2
KHDCS-40
1 309 055 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
Weight
kg
For dimensions
see page 1673
0.225
- without integral
coil suppressor
0.225
0.225
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCF-31
1 309 165 ..
3
1
KHDCF-22
1 309 175 ..
2
2
KHDCF-40
1 309 155 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
Weight
kg
For dimensions
see page 1673
0.225
- without integral
coil suppressor
0.225
0.225
Version with solder pins, 1.7 mm Ø, hole on p. c. b.
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCL-31
1 309 265 ..
3
1
KHDCL-22
1 309 275 ..
2
2
KHDCL-40
1 309 255 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
0.225
- without integral
coil suppressor
1)
1638
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
0.225
0.225
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
Weight
kg
Auxiliary contact block - page 1641
Other system components - page 1641
Technical details - pages 1664, 1666
For dimensions
see page 1673
S014007
000919
Control relays KHDC ...,
DC operated
with integral coil suppressor
Terminal numbering to DIN EN 50 011
Compact design
Available in 3 versions :
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Forced opening of contacts
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
Further notes at the bottom of this page.
Approvals:
Characteristics for control relays KHDC ..., DC operated, 3 W coils
Version with screw terminals
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCS-31
1 309 066 ..
3
1
KHDCS-22
1 309 076 ..
2
2
KHDCS-40
1 309 056 ..
4
0
Circuit diagram to
DIN EN 50 011
Features
- with integral
coil suppressor
Weight
kg
For dimensions
see page 1673
0.225
0.225
- permitted up to
240 V max.
0.225
Features
Weight
kg
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCF-31
1 309 166 ..
3
1
KHDCF-22
1 309 176 ..
2
2
KHDCF-40
1 309 156 ..
4
0
Circuit diagram to
DIN EN 50 011
- with integral
coil suppressor
For dimensions
see page 1673
0.225
0.225
- permitted up to
240 V max.
0.225
Features
Weight
kg
Version with solder pins, 1.7 mm Ø, hole on p. c. b.
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHDCL-31
1 309 266 ..
3
1
KHDCL-22
1 309 276 ..
2
2
KHDCL-40
1 309 256 ..
4
0
Circuit diagram to
DIN EN 50 011
- with integral
coil suppressor
For dimensions
see page 1673
0.225
0.225
- permitted up to
240 V max.
0.225
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
DC-coils available with integral coil suppressor to max. 220 V
1)
Auxiliary contact block - page 1641
Other system components - page 1641
Technical details - pages 1664, 1666
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
1639
S014008
000919
Control relays KHi (interface),
DC operated
with integral coil suppressor and
LED to indicate operational state
Terminal numbering to DIN EN 50 011
Compact design, same size as AC control relay
Version :
- with screw terminals
Low power consumption coils
High contact reliability
Switch position indication
Positively guided terminals
Can be directly controlled by programmable
controller
Safety isolation up to 400 V to VDE 0106, IEC 536
Further notes at the bottom of this page.
Approvals:
Characteristics for contol relays KHiS ..., DC operated, interface, 1.8 W coil
Version with screw terminals
Rated thermal
current Ith
A
10
Type
Order ref.:
see supplements
at the top right
Contact
configuration
N/O N/C
KHiS-31
1 309 067 06
3
1
KHiS-22
1 309 077 06
2
2
KHiS-40
1 309 057 06
4
0
Circuit diagram to
DIN EN 50 011
Features
- built-in LED to indicate
operational state
- Coil operating voltage
rangs 0.7 to 1.3 VC
- integral coil
suppressor
- only 2 pole aux.
contact block
permitted
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1640
DC: 24 and 48 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1641
Other system components - page 1641
Technical details - pages 1664, 1666
Weight
kg
0.235
0.235
0.235
For dimensions
see page 1673
000919
S014009
Mini contactors: system components
for use with control relays, contactors, and
reversing contactors
Auxiliary contact blocks, 2- or 4-pole, front fitting
Compact in size, mounts quickly
Available in 2 versions :
S = screw terminals
F = Faston connectors
Contact positioning and numbering to DIN EN
50011 on types HS/HF when mounted to control
relays with 4 N/O contacts
When mounted to contactors, DIN EN 50012 is
maintained when LS contacts are used
High contact reliability
Switch position indication
3 front mounting coil suppressor versions with LED
indicators
Front mounting timer module, delay on energization
up to 30 secs
Approvals:
Characteristics
Auxiliary contact blocks
for use with KL ..., KLW contactors
for use with KH ..., KHDC ..., KHi control relays
Coil suppressors with built-in LED indicator
RC coil suppressor (for AC operated contactor)
Top mounting
for contactors
Type
DIN EN 50 012
LS-11
3 309 001 01
LS-02
3 309 002 01
Type
Voltage range
Order ref.:
LS-13
3 309 005 01
D-242)
D-482)
12...24 =
32...48 =
3 309 061 01
3 309 061 02
LS-22
3 309 004 01
LS-31
3 309 003 01
KL ...
KLW ...
Circuit diagram
Order ref.:
Type
Voltage range
Order ref.:
RC-2501)
220...250 V
3 309 062 01
Diode coil suppressor (for DC operated contactor)
Varistor coil suppressor (for AC or DC operated contactor)
Type
3)
HS-02
3 309 033 01
HF-02
3 309 043 01
HS-04
3 309 038 01
HF-04
3 309 048 01
HS-11
3 309 032 01
HF-11
3 309 042 01
KH, KHDC,
HS-13
3 309 037 01
KHi
HF-13
3 309 047 01
HS-20
3 309 031 01
HF-20
3 309 041 01
HS-22
3 309 036 01
HF-22
3 309 046 01
HS-31
3 309 035 01
HF-31
3 309 045 01
HS-40
3 309 034 01
HF-40
3 309 044 01
Weight : 0.045 kg
V-24
V-483)
V-1303)
V-2503)
Voltage range
Order ref.:
12...24 AC/DC
32...48 AC/DC
40...129 AC/DC
130...250 AC/DC
3 309 060 01
3 309 060 02
3 309 060 04
3 309 060 05
Weight : 0.010 kg
Timer module snaps to the front of contactor
Type
Timer range
Voltage range
input/coil
Order ref.:
HV-48
HV-240
1...30
1...30
24...48 V AC/DC
110...240 V AC
3 309 050 01
3 309 050 02
Weight : 0.040 kg
Technical details :
Relay outputs
240 V AC/DC, 2 A max.
Max. switching capacity
250 VA / 150 W
Control voltage range 0.85...1.1 VC
Permissible ambient temperature
-10°C ... +60°C
Reset time :
1.5 secs while timing
0.5 secs after timing
Circuit diagram :
1W
Explanation :
... S = screw terminals
... F = Faston connectors
on KHi only 2-pole versions
permitted !
Notes
1)
2)
3)
Limits transient voltage to max. 3 Vc. Slight increase in drop-out time
(1.2 to 2 times the normal time).
No interference by transient voltages and high frequency. Observe polarity when
connecting. Slight increase in drop-out time (1.1 to 1.5 times the normal time).
Limits transient voltages to max. 2 Vc. Max. reduction of transient voltage
peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time).
Technical details - pages 1664-1666
Dimensions - page 1673
1641
S014010
000623
Contactors KL ...,
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
Terminal numbering to DIN EN 50 005 and
without integral coil suppressor
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
KL contactors are designed to switch three-phase and
AC loads. Applications include building automation,
air conditioning, heating and ventilation, and switching
resistive loads such as heaters, lamps, and inductive
loads, e.g., valves, couplings, etc.
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for contactors KL ..., AC operated, 4.5 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
1.5
2.2
2.2
4
3
4
3
4
KL2S-10
1 309 000 ..
KL2S-01
1 309 010 ..
- 50/60 Hz coil
KL4S-10
1 309 020 ..
- without integral
coil suppressor
KL4S-01
1 309 030 ..
20/6
20/9
0.180
M 06
0.180
M 06
0.210
M 06
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
1.5
2.2
2.2
4
3
4
3
4
KL2F-10
1 309 100 ..
KL2F-01
1 309 110 ..
- 50/60 Hz coil
KL4F-10
1 309 120 ..
- without integral
coil suppressor
KL4F-01
1 309 130 ..
20/6
20/9
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
1.5
2.2
2.2
4
3
4
3
4
KL2L-10
1 309 200 ..
KL2L-01
1 309 210 ..
- 50/60 Hz coil
KL4L-10
1 309 220 ..
- without integral
coil suppressor
KL4L-01
1 309 230 ..
20/6
20/9
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1642
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
For dimensions
see page 1673
S014011
000919
Contactors KL ...,
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
with integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
KL contactors are designed to switch three-phase and
AC loads. Applications include building automation,
air conditioning, heating and ventilation, and switching
resistive loads such as heaters, lamps, and inductive
loads, e.g., valves, couplings, etc.
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for contactors KL ..., AC operated, 4.5 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
For dimensions
see page 1673
Version with screw terminals
KL2S-10
1.5
2.2
2.2
4
3
4
3
4
1 309 002 ..
- 50/60 Hz coil
KL2S-01
1 309 012 ..
- with integral
coil suppressor
KL4S-10
1 309 022 ..
KL4S-01
1 309 032 ..
20/6
0.180
M 06
0.180
M 06
0.210
M 06
20/9
permitted up to
240 V max.
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
KL2F-10
1.5
2.2
2.2
4
3
4
3
4
1 309 102 ..
- 50/60 Hz coil
KL2F-01
1 309 112 ..
- with integral
coil suppressor
KL4F-10
1 309 122 ..
KL4F-01
1 309 132 ..
20/6
20/9
permitted up to
240 V max.
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
KL2L-10
1.5
2.2
2.2
4
3
4
3
4
1 309 202 ..
- 50/60 Hz coil
KL2L-01
1 309 212 ..
- with integral
coil suppressor
KL4L-10
1 309 222 ..
KL4L-01
1 309 232 ..
20/6
20/9
permitted up to
240 V max.
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
AC-coils available with integral coil suppressor to max. 230 V
1)
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
1643
S014012
000919
Contactors KLDC ...,
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
DC operated,
without integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
KLDC contactors are designed to switch three-phase
and AC loads. Applications include building automation,
air conditioning, heating and ventilation, and switching
resistive loads such as heaters, lamps, and inductive
loads, e.g., valves, couplings, etc.
Further notes at the bottom of this page.
Approvals:
Characteristics for contactors KLDC ..., DC operated, 3 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
1.5
2.2
2.2
4
3
4
3
4
KLDC2S-10
1 309 005 ..
KLDC2S-01
1 309 015 ..
KLDC4S-10
1 309 025 ..
KLDC4S-01
1 309 035 ..
20/6
- without integral
coil suppressor
0.225
M 06
- without integral
coil suppressor
0.225
M 06
- without integral
coil suppressor
0.225
M 06
20/9
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
1.5
2.2
2.2
4
3
4
3
4
KLDC2F-10
1 309 105 ..
KLDC2F-01
1 309 115 ..
KLDC4F-10
1 309 125 ..
KLDC4F-01
1 309 135 ..
20/6
20/9
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
1.5
2.2
2.2
4
3
4
3
4
KLDC2L-10
1 309 205 ..
KLDC2L-01
1 309 215 ..
KLDC4L-10
1 309 225 ..
KLDC4L-01
1 309 235 ..
20/6
20/9
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1644
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
For dimensions
see page 1673
S014013
000919
Contactors KLDC ...,
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
DC operated
with integral coil suppressor
Terminal numbering DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
KLDC contactors are designed to switch three-phase
and AC loads. Applications include building automation,
air conditioning, heating and ventilation, and switching
of resistive loads such as heaters, lamps, and inductive
loads, e.g., valves, couplings, etc.
Further notes at the bottom of this page.
Approvals:
Characteristics for contactors KLDC ..., DC operated, 3 W coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
For dimensions
see page 1673
Version with screw terminals
1.5
2.2
2.2
4
3
4
3
4
KLDC2S-10
1 309 006 ..
KLDC2S-01
1 309 016 ..
KLDC4S-10
1 309 026 ..
KLDC4S-01
1 309 036 ..
20/6
- with integral
coil suppressor
0.225
M 06
0.225
M 06
0.225
M 06
20/9
permitted up to
240 V max.
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
1.5
2.2
2.2
4
3
4
3
4
KLDC2F-10
1 309 106 ..
KLDC2F-01
1 309 116 ..
KLDC4F-10
1 309 126 ..
KLDC4F-01
1 309 136 ..
20/6
- with integral
coil suppressor
20/9
permitted up to
240 V max.
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
1.5
2.2
2.2
4
3
4
3
4
KLDC2L-10
1 309 206 ..
KLDC2L-01
1 309 216 ..
KLDC4L-10
1 309 226 ..
KLDC4L-01
1 309 236 ..
20/6
- with integral
coil suppressor
20/9
permitted up to
240 V max.
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
DC-coils available with integral coil suppressor to max. 220 V
1)
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
1645
S014014
000731
Interface contactors KLi ...
4 kW / 5 HP at 460 V, 3 ph. (AC 3)
DC operated,
with integral coil suppressor and
LED switch position indication
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Switch position indication
Can be directly controlled by programmable
controllers
Safety isolation up to 400 V to VDE 0106, IEC 536
Further notes at the bottom of this page.
Approvals:
Characteristics for contactors KLi ..., DC operated, 1.8 W coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
2.2
4
4
4
KLi4S-10
1 309 027 ..
KLi4S-01
1 309 037 ..
20/9
- Built in LED to indicate switch position
- Coil voltage range
from 0.7 to 1.3 Vc
- Integral coil
suppressor up to
72 V max.
- Only 2 pole aux.
contact block
permitted
0.235
M 06
0.235
M 06
0.265
M 06
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
2.2
4
4
4
KLi4F-10
1 309 127 ..
KLi4F-01
1 309 137 ..
20/9
- Built in LED to indicate switch position
- Coil voltage range
from 0.7 to 1.3 Vc
- Integral coil
suppressor up to
72 V max.
- Only 2 pole aux.
contact block
permitted
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
2.2
4
4
4
KLi4L-10
1 309 227 ..
KLi4L-01
1 309 237 ..
20/9
- Buil-in LED to indicate switch position
- Coil voltage range
from 0.7 to 1.3 Vc
- Integral coil
suppressor up to
72 V max.
- Only 2 pole aux.
contact block
permitted
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1646
DC: 24 and 48 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
For dimensions
see page 1673
S014015
000623
Contactors KLb ...,
4 kW / 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
with integral coil suppressor
hum-free for special
applications
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
- KLi contactors are hum free which makes them
suitable for use in building equipment, etc.
- Magnet coil with integral rectifier and coil suppressor
- Suitable for rail mounting (35 mm rail) or screw fixing
(4 mm dia. screws)
- Connecting screws are supplied with the clamps in
the open position
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for contactors KLb ..., AC operated, 3 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to Features
DIN EN 50 005 and
DIN EN 50 012
Weight Suitable
kg
thermal
overload
relay
For dimensions
see page 1673
Version with screw terminals
50/60 Hz coil
24 V
110 V
KLb4S-10
2.2
4
4
4
1 309 021 ..
20/9
KLb4S-01
1 309 031 ..
230 V
permitted
0.225
M 06
0.225
M 06
0.225
M 06
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
50/60 Hz coil
24 V
110 V
KLb4F-10
2.2
4
4
4
1 309 121 ..
20/9
KLb4F-01
1 309 131 ..
230 V
permitted
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
50/60 Hz coil
24 V
110 V
KLb4L-10
2.2
4
4
4
1 309 221 ..
20/9
KLb4L-01
1 309 231 ..
230 V
permitted
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
AC: 24, 110 and 230 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
1647
S014016
000623
Reversing contactors KLW ..., 3 pole
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
without integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
- Mechanically interlocked as standard
- Main circuit is ready wired on contactors with screw
terminals
- Suitable for rail mounting (35 mm rail) or screw fixing
(4 mm dia. screw)
- Connecting screws are supplied with the clamps in
the open position
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for reversing contactors KLW ..., AC operated, 4.5 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to
DIN EN 50 005 and
DIN EN 50 012
Features
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
1.5
2.2
2.2
4
3
4
3
4
KLW2S-10
1 309 300 ..
KLW2S-01
1 309 310 ..
KLW4S-10
1 309 320 ..
KLW4S-01
1 309 330 ..
20/6
without
integral coil
suppressor
0.39
M 06
without
integral coil
suppressor
0.37
M 06
without
integral coil
suppressor
0.43
M 06
20/9
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
1.5
2.2
2.2
4
3
4
3
4
KLW2F-10
1 309 400 ..
KLW2F-01
1 309 410 ..
KLW4F-10
1 309 420 ..
KLW4F-01
1 309 430 ..
20/6
20/9
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
1.5
2.2
2.2
4
3
4
3
4
KLW2L-10
1 309 500 ..
KLW2L-01
1 309 510 ..
KLW4L-10
1 309 520 ..
KLW4L-01
1 309 530 ..
20/6
20/9
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1648
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
For dimensions
see page 1673
S014017
000623
Reversing contactors KLW ..., 3 pole
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
with integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
- Mechanically interlocked as standard
- Main circuit is ready wired on contactors with screw
terminals
- Suitable for rail mounting (35 mm rail) or screw fixing
(4 mm dia. screw)
- Connecting screws are supplied with the clamps in
the open position
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Further notes at the bottom of this page.
Approvals:
Characteristics for reversing contactors KLW ..., AC operated, 4.5 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to
DIN EN 50 005 and
DIN EN 50 012
Features
Weight Suitable
kg
thermal
overload
relay
For dimensions
see page 1673
Version with screw terminals
1.5
2.2
2.2
4
3
4
3
4
with
integral coil
suppressor
KLW2S-10
1 309 302 ..
KLW2S-01
1 309 312 ..
KLW4S-10
1 309 322 ..
KLW4S-01
1 309 332 ..
permitted up
to 240 V max.
KLW2F-10
1 309 402 ..
with
integral coil
suppressor
KLW2F-01
1 309 412 ..
KLW4F-10
1 309 422 ..
KLW4F-01
1 309 432 ..
permitted up
to 240 V max.
KLW2L-10
1 309 502 ..
with
integral coil
suppressor
KLW2L-01
1 309 512 ..
KLW4L-10
1 309 522 ..
KLW4L-01
1 309 532 ..
20/6
0.39
M 06
0.37
M 06
0.43
M 06
20/9
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
1.5
2.2
2.2
4
3
4
3
4
20/6
20/9
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
1.5
2.2
2.2
4
3
4
3
4
20/6
20/9
permitted up
to 240 V max.
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
AC-coils available with integral coil suppressor to max. 230 V
1)
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
1649
S014018
000731
Reversing contactors KLWDC ..., 3 pole
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
DC operated,
without integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Switch position indication
With or without integral coil suppressor
Safety isolation up to 400 V to VDE 0106, IEC 536
- Mechanically interlocked as standard
- Main circuit is prewired on contactors with screw
terminals
- Suitable for rail mounting (35 mm rail) or screw fixing
(4 mm dia. screw)
- Connecting screws are supplied with the clamps in
the open position
Further notes at the bottom of this page.
Approvals:
Characteristics for reversing contactors KLWDC ..., DC operated, 3 W coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to
DIN EN 50 005 and
DIN EN 50 012
Features
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
KLWDC2S-10 1 309 305 ..
1.5
2.2
3
3
20/6
KLWDC2S-01 1 309 315 ..
KLWDC4S-10 1 309 320 ..
2.2
4
4
4
without
integral coil
suppressor
0.39
M 06
without
integral coil
suppressor
0.39
M 06
without
integral coil
suppressor
0.39
M 06
20/9
KLWDC4S-01 1 309 335 ..
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
KLWDC2F-10 1 309 405 ..
1.5
2.2
3
3
20/6
KLWDC2F-01 1 309 415 ..
KLWDC4F-10 1 309 320 ..
2.2
4
4
4
20/9
KLWDC4F-01 1 309 435 ..
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
KLWDC2L-10 1 309 505 ..
1.5
2.2
3
3
20/6
KLWDC2L-01 1 309 515 ..
KLWDC4L-10 1 309 320 ..
2.2
4
4
4
20/9
KLWDC4L-01 1 309 535 ..
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1650
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
For dimensions
see page 1673
S014019
000731
Reversing contactors KLWDC ..., 3 pole
2.2 and 4 kW / 3 and 5 HP at 460 V, 3 ph. (AC 3)
DC operated,
with integral coil suppressor
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
- Mechanically interlocked as standard
- Main circuit is prewired on contactors with screw
terminals
- Suitable for rail mounting (35 mm rail) or screw
attached (4 mm dia. screw)
- Connecting screws are supplied with the clamps in
the open position
Further notes at the bottom of this page.
Approvals:
Characteristics for reversing contactors KLWDC ..., DC operated, 3 W coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to
DIN EN 50 005 and
DIN EN 50 012
Features
Weight Suitable
kg
thermal
overload
relay
For dimensions
see page 1673
Version with screw terminals
KLWDC2S-10 1 309 306 ..
1.5
2.2
3
3
20/6
with
integral coil
suppressor
KLWDC2S-01 1 309 316 ..
0.48
M 06
0.46
M 06
0.52
M 06
KLWDC4S-10 1 309 326 ..
2.2
4
4
4
20/9
KLWDC4S-01 1 309 336 ..
permitted up
to 240 V
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
KLWDC2F-10 1 309 406 ..
1.5
2.2
3
3
20/6
with
integral coil
suppressor
KLWDC2F-01 1 309 416 ..
KLWDC4F-10 1 309 426 ..
2.2
4
4
4
20/9
KLWDC4F-01 1 309 436 ..
permitted up
to 240 V
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
KLWDC2L-10 1 309 506 ..
1.5
2.2
3
3
20/6
with
integral coil
suppressor
KLWDC2L-01 1 309 516 ..
KLWDC4L-10 1 309 526 ..
2.2
4
4
4
20/9
KLWDC4L-01 1 309 536 ..
permitted up
to 240 V
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
DC: 24, 110 and 220 V
DC-coils available with integral coil suppressor to max. 220 V
1)
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - pages 1664-1665
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
1651
S014020
000623
Reversing contactors KLWb ..., 3 pole
4 kW / 5 HP at 460 V, 3 ph. (AC 3)
AC operated,
hum-free for
special applications
Terminal numbering to DIN EN 50 005 and
DIN EN 50 012
Compact design
Available in 3 versions:
- with screw terminals
- Faston connectors
- solder pins
Version with solder pins includes front face screw
terminals for direct connection to load
Low power consumption coils
Bi-frequency AC coils 50/60 Hz
High contact reliability
Switch position indication
Safety isolation up to 400 V to VDE 0106, IEC 536
- KLWb contactors are hum-free which makes them
suitable for use in building equipment, etc.
- Magnet coil with integral rectifier and coil suppressor
- Mechanically interlocked as standard
- Main circuit is prewired on contactor with screw
terminals
- Suitable for rail mounting (35 mm rail) or screw
attached (4 mm dia. screw)
- Connecting screws are supplied with the clamps in
the open position
Our mini contactors are delivered with
bi-frequency coils for 50/60 Hz.
Approvals:
Further notes at the bottom of this page.
Characteristics for reversing contactors KLWb ..., AC operated, 3 VA coils
Max. AC 3 ratings
of 3-phase motors
(kW)
380...
230 V 415 V 500 V
Rated operational current
Ie AC 1/AC 3
up to 440 V
690 V
A
Contactor
type
Order ref.:
see supplements at the
top right
Circuit diagram to
DIN EN 50 005 and
DIN EN 50 012
Features
Weight Suitable
kg
thermal
overload
relay
Version with screw terminals
50/60 Hz
coil
... 24 V
2.2
4
4
4
KLWb4S-10
1 309 321 ..
... 110 V
KLWb4S-01
1 309 331 ..
permitted
0.48
M 06
0.46
M 06
0.52
M 06
... 230 V
20/9
Version with Faston connectors, 2 x 2.8 mm or 1 x 6.35 mm
50/60 Hz
coil
... 24 V
KLWb4F-10
2.2
4
4
4
1 309 421 ..
... 110 V
... 230 V
20/9
KLWb4F-01
1 309 431 ..
permitted
Version with solder pins, 1,7 mm Ø, hole on p. c. b.
50/60 Hz
coil
... 24 V
2.2
4
4
4
KLWb4L-10
1 309 521 ..
... 110 V
KLWb4L-01
1 309 531 ..
permitted
... 230 V
20/9
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1652
AC: 24, 110 and 230 V
Color code to IEC 309-1 printed on the coil.
Only for compact contactors, HL 4 K / HL 8 K and DL 4 K - DL 18 K
Auxiliary contact block - page 1653
Other system components - page 1653
Technical details - page 1664-1665
For dimensions
see page 1673
S014022
000623
Mini contactors: system components
for use with control relays, contactors and
reversing contactors
Auxiliary contact blocks, 2- or 4-pole, front fitting
Compact in size, mounts quickly
Available in 2 versions :
S = screw terminals
F = Faston connectors
Contact positioning and numbering to DIN EN
50011 on types HS/HF when mounted to control
relays with 4 N/O contacts
When mounted to contactors, DIN EN 50012 is
maintained when LS contacts are used
High contact reliability
Switch position indication
3 front mounting coil suppressor versions with LED
indicators
Front mounting timer module, delay on energization
up to 30 seconds
Approvals:
Characteristics
Auxiliary contact blocks
for use with KL ..., KLW contactors
for use with KH ..., KHDC ..., KHi control relays
Coil suppressors with built in LED indicator
RC coil suppressor (for AC operated contactor)
Top mounting
for contactors
Type
DIN EN 50 012
LS-11
3 309 001 01
LS-02
3 309 002 01
Type
Voltage range
Order ref.:
LS-13
3 309 005 01
D-242)
D-482)
12...24 =
32...48 =
3 309 061 01
3 309 061 02
LS-22
3 309 004 01
LS-31
3 309 003 01
KL ...
KLW ...
Circuit diagram
Order ref.:
Type
Voltage range
Order ref.:
RC-2501)
220...250 V
3 309 062 01
Diode coil suppressor (for DC operated contactor)
Varistor coil suppressor (for AC or DC operated contactor)
Type
3)
HS-02
3 309 033 01
HF-02
3 309 043 01
HS-04
3 309 038 01
HF-04
3 309 048 01
HS-11
3 309 032 01
HF-11
3 309 042 01
KH, KHDC,
HS-13
3 309 037 01
KHi
HF-13
3 309 047 01
HS-20
3 309 031 01
HF-20
3 309 041 01
HS-22
3 309 036 01
HF-22
3 309 046 01
HS-31
3 309 035 01
HF-31
3 309 045 01
HS-40
3 309 034 01
HF-40
3 309 044 01
Weight : 0.045 kg
V-24
V-483)
V-1303)
V-2503)
Voltage range
Order ref.:
12...24 AC/DC
32...48 AC/DC
40...129 AC/DC
130...250 AC/DC
3
3
3
3
309
309
309
309
060
060
060
060
01
02
04
05
Weight : 0.010 kg
Timer module snaps to the front of contactor
Type
Timer range
Voltage range
input/coil
Order ref.:
HV-48
HV-240
1...30
1...30
24...48 V AC/DC
110...240 V AC
3 309 050 01
3 309 050 02
Weight : 0.040 kg
Technical details :
Relay outputs
240 V AC/DC, 2 A max.
Max. switching capacity
250 VA / 150 W
Control voltage range 0.85...1.1 VC
Permissible ambient temperature
-10°C ... +60°C
Reset time :
1.5 secs while timing
0.5 secs after timing
Circuit diagram :
1W
Explanation :
... S = screw terminals
... F = Faston connectors
on KHi only 2-pole versions
permitted !
Notes
1)
2)
3)
Limits transient voltage to max. 3 Vc. Slight increase in drop-out time
(1.2 to 2 times the normal time).
No interference by transient voltages and high frequency. Observe polarity when
connecting. Slight increase in drop-out time (1.1 to 1.5 times the normal time).
Limits transient voltages to max. 2 Vc. Max. reduction of transient voltage
peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time).
Technical details - pages 1664-1666
Dimensions - page 1673
1653
S014021
000919
Voltage code numbers 04 ...73
to be added to the contactor order reference
number for mini contactors
Code
number
AC
... 04
... 06
... 10
... 11
... 13
... 15
... 19
... 25
... 28
... 29
... 38
... 40
... 41
... 43
... 59
... 61
... 63
... 65
... 69
... 73
Color code1)
for coil voltage
DC
12 V
24 V
32 V
36 V
42 V
48 V
60 V
110 V
120 V
127 V
125 V
208 V
230 V
220 V
240 V
400 V
380 V
415 V
440 V
500 V
600 V
220 V
AC
DC
violet
violet
violet
green
white
white
green
yellow
yellow
yellow
blue
blue
blue
blue
red
red
red
red
black
black
green
green
green
green
green
green
green
green
green
green
green
green
-
Our control relays, compact contactors and mini contactors are delivered
with bi-frequency coils for 50/60 Hz.
Our N-contactors are available with mono-frequency coils for 50 or 60 Hz.
Notes
Normal/Standard voltages are:
(Short-term availability)
Other coil voltages on request
1)
1654
AC: 24, 42, 110, 230 and 400 V
DC: 24, 110 and 220 V
Color code to IEC 309-1 printed on the coil. Only for compact contactors HL 4 K / HL 8 K and DL 4 K - DL 18 K
NOTES
1655
1002T
010329
Motor Controls
Entrelec MTE is a leading supplier of motor control and protection
products for a wide range of industrial applications. Products
include innovative electronic equipment including soft-starters,
DC injection brakes, and advanced motor protection and
monitoring modules. All products are manufactured to
ISO 9001 standards.
Electronic Soft Starters: DuoSoft and PowerSoft
DuoSoft
DuoSoft and PowerSoft electronic soft starters provide smooth acceleration and
deceleration of three phase motors, reducing mechanical and electrical stress which
shorten a motor’s life. DuoSoft starters are suitable for motors up to 15 kW.
PowerSoft starters come in two versions, a chassis model to incorporate into a
separate enclosure and a complete ready-to-go starter suitable for wall mounting.
DuoSoft
• Suitable for motors up to 15 kW
• Ideal alternative to Star Delta starters
• Integral bypass relay
• Compact size
• Two or three wire control
• LED status indication
PowerSoft chassis model
PowerSoft - chassis model
PowerSoft - complete starter
• The system integrator’s choice
• Installs into a separate enclosure
• Compact IP20 construction
• Adaptable for a wide range
of applications
• The installers’ choice
• For wall mounting
• Self-contained IP55 unit (IP42 above 40 kW)
• Easy to install
• Incorporates isolator, line contactor,
start stop buttons, and motor
overload protection
Contact Entrelec for details.
Fuse Disconnect Switches
ZNTF
Fuse Switches
ZNTF
• Up to 100A rating.
• Door interlocked handle standard
• Two auxiliary contacts can be mounted
• Auxiliaries feature early break/late make
ZTF
ZTF
• Larger fuse switch to 800A rating
• Includes door interlocked handle and fuse barriers
• Four auxiliary contacts can be mounted
• Fourth pole not fused
• Auxiliaries feature early break/late make
Contact Entrelec for details.
1656
1003T
010329
Motor Protection: Maxim
Products for protecting, monitoring,
and controlling motors.
50% of motor failures are triggered by overheating due
to overload, phase failure, or insulation breakdown.
A 10% temperature rise reduces your motor’s life by
50%. The Maxim range of products protect your
motor against the cause of temperature rise. Devices
within the range also provide protection against other
causes of motor and equipment damage, including:
• Dry pump
• Belt break on conveyor or fan
• Mixer jamming
• Excess conveyor loading
Contact Entrelec for details.
Monitors 6 functions
Monitors 16 functions with bus communication
DC Injection Brakes
Our DC Injection brakes reduce the time for a machine to come to rest resulting in
an increased production output and increased safety in hazardous machines.
Available in three formats with DOL starter, with Star Delta starter, and without
starter (for use with existing DOL or Star Delta starter).
• Reduced stopping time
• Increased production cycle
• Smooth controlled stopping
• Adjustable braking torque and stop time
• Easy installation
• Maintenance free
Meets the guidelines of PUWER 98,
developed in the United Kingdom.
Contact Entrelec for details.
Power Manager
Power Manager provides comprehensive electrical network information that
economically replaces ammeters, voltmeters, meter switches, kWh meters,
power factor meters, kW meters, and more. Compact and easy to use, Power
Manager provides accurate measurement to the 20th Harmonic on each cycle.
The combination of performance, simplicity, and size ensures that Power
Manager is the ideal solution for switchboard and control panel manufacturers.
• Simple to install
Quick fit clamps for panel mounting
and large cable terminals
• Easy to use
Four menu buttons allow information
to be accessed easily and quickly
• Accurate and comprehensive
parameter measurement
• Easy to read
Large clear backlit LCD display
• Compact size
Contact Entrelec for details.
1657
NOTES
1658
S015003
000623
Fusing of squirrel cage motors 50 Hz 1500 r. p. m. up to and including 25 kW
(guide values). For values applicable to contactors and thermal overload relays, see "technical details"
Motor rating
Motor rated current
at 125 V
Fusing
DOL
Y∆
Motor rated current
at 230 V
Fusing
DOL
Y∆
Motor rated current
at 240 V
Fusing
DOL
Y∆
Motor rated current
at 400 V
Fusing
DOL
Y∆
kW
PS ≈ hp
cos ϕ
η%
A
A
A
A
A
A
A
A
A
A
A
A
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
0.8
1.1
1.5
2.2
2.5
3
3.7
4
5
5.5
6.5
7.5
8
11
12.5
15
18.5
20
22
25
0.08
0.12
0.16
0.24
0.34
0.5
0.75
1
1.1
1.5
2
3
3.4
4
5
5.5
6.8
7.5
8.8
10
11
15
17
20
25
27
30
34
0.7
0.7
0.7
0.7
0.7
0.72
0.75
0.8
0.8
0.83
0.83
0.83
0.83
0.84
0.84
0.84
0.84
0.85
0.85
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.87
0.87
59
60
61
61
62
64
69
74
74
77
78
81
81
81
82
82
83
83
84
85
85
87
87
87
88
88
89
89
0.67
0.99
1.29
1.93
2.69
3.7
4.4
5.9
6.3
7.8
10.7
15.2
17.3
20.4
25
26.8
33.1
36.4
42.2
47.6
-
2
2
4
4
4
6
10
10
16
16
20
25
25
35
35
35
50
63
63
63
-
2
2
2
4
4
4
6
10
10
10
16
20
20
25
35
36
50
50
50
50
-
0.38
0.55
0.76
1.1
1.4
2.1
2.7
3.3
3.6
4.9
6.2
8.7
9.8
11.6
14.2
15.3
18.9
20.6
23.7
27.4
28.8
39.2
43.8
52.6
64.9
69.3
75.2
84.4
1
2
2
2
4
4
4
6
6
10
10
16
16
20
25
25
35
35
35
35
50
63
63
80
100
100
100
125
1
2
2
2
2
4
4
4
4
6
10
10
16
16
20
20
25
25
25
35
35
50
50
63
80
80
80
100
0.35
0.5
0.68
1
1.38
1.93
2.3
3.1
3.3
4.1
5.6
7.9
8.9
10.6
13
14
17.2
18.9
21.8
24.8
26.4
35.3
40.2
48.2
58.7
63.4
68
77.2
1
2
2
2
4
4
4
6
6
6
10
16
16
20
25
25
25
35
35
35
35
50
63
80
80
80
100
100
1
2
2
2
2
4
4
4
4
6
10
10
10
16
16
20
20
25
25
35
35
50
50
63
63
80
80
100
0.22
0.33
0.42
0.64
0.88
1.22
1.5
2
2.1
2.6
3.5
5
5.7
6.6
8.2
8.5
10.5
11.5
13.8
15.5
16.7
22
25
30
37
40
44
50
1
1
2
2
2
4
4
4
4
4
6
10
10
16
16
16
20
20
25
25
25
35
35
50
63
63
63
80
1
1
2
2
2
2
2
4
4
4
4
6
10
10
10
10
16
16
16
20
20
25
35
35
50
50
50
63
Motor rating
kW
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
0.8
1.1
1.5
2.2
2.5
3
3.7
4
5
5.5
6.5
7.5
8
11
12.5
15
18.5
20
22
25
PS ≈ hp
0.08
0.12
0.16
0.24
0.34
0.5
0.75
1
1.1
1.5
2
3
3.4
4
5
5.5
6.8
7.5
8.8
10
11
15
17
20
25
27
30
34
cos ϕ
0.7
0.7
0.7
0.7
0.7
0.72
0.75
10.8
0.8
0.83
0.83
0.83
0.83
0.84
0.84
0.84
0.84
0.85
0.85
0.86
0.86
0.86
0.86
0.86
0.86
0.86
0.87
0.87
η%
59
60
61
61
62
64
69
74
74
77
78
81
81
81
82
82
83
83
84
85
85
87
87
87
88
88
89
89
Motor rated current
at 415 V
Fusing
DOL
Y∆
Motor rated current
at 440 V
Fusing
DOL
Y∆
Motor rated current
at 500 V
Fusing
DOL
Y∆
Motor rated current
at 600 V
Fusing
DOL
Y∆
Motor rated current
at 660 V
Fusing
DOL Y∆
A
2
2.5
3.5
5
6.5
7.5
11
14
21
28
35
40
-
A
0.19
0.28
0.37
0.55
0.76
1.06
1.25
1.67
1.78
2.26
3.03
4.31
4.9
5.8
7.1
7.6
9.4
10.3
12
13.5
14.4
19.3
21.9
26.3
32
34.6
37.1
42.1
A
0.16
0.24
0.33
0.46
0.59
0.85
1.2
1.48
1.57
2.1
2.6
3.8
4.3
5.1
6.2
6.5
8.1
8.9
10.4
11.9
12.7
16.7
19
22.5
28.5
30.6
33
38
A
0.12
0.21
0.27
0.4
0.56
0.77
1.02
1.22
1.31
1.66
2.22
3.16
3.59
4.25
5.2
5.6
6.9
7.5
8.7
9.9
10.6
14.1
16.1
19.3
23.5
25.4
72.2
30.9
A
0.7
0.9
1.1
1.5
2
2.9
3.5
4.9
6.7
9
13
17.5
21
25
-
A
4
4
6
10
16
16
20
25
35
35
50
63
-
A
4
4
4
6
10
10
16
16
25
35
50
50
-
A
1
1
1
1
2
2
4
4
4
4
6
6
10
10
16
16
16
20
20
25
25
35
35
35
50
50
63
63
A
1
1
1
1
2
2
2
2
2
4
4
6
6
10
10
10
16
16
16
16
20
25
25
35
35
50
50
50
A
1
1
1
1
2
2
4
4
4
4
4
6
6
10
16
16
16
16
20
20
20
25
35
35
50
50
50
63
A
1
1
1
1
2
2
2
2
2
4
4
6
6
10
10
10
10
10
16
16
16
20
25
25
35
35
50
50
A
1
1
1
1
1
2
2
4
4
4
4
6
6
6
10
10
16
16
16
16
20
25
25
35
35
35
35
50
A
1
1
1
1
1
2
2
2
2
2
4
4
4
6
10
10
10
10
10
16
16
20
20
25
25
35
35
35
A
2
2
2
4
4
6
6
10
16
16
25
25
35
35
-
A
2
2
2
2
4
4
4
6
10
10
16
20
25
35
-
The motor rated currents are valid for normal internal and surface cooled-down three-phase current motors of 1500 r. p. m.
Direct-on-line-starting: Starting current max. 6 x motor rated current. Starting time: max. 5 sec.
Y/∆-current: Starting current max. 2 x motor rated current. Starting time max. 15 s. Thermal overload relay in the delta circuit to be set at 0.58 x motor rated current.
The rated currents of the fuse at Y/∆ -starting are also applicable for asynchronous slip-ring motors. At higher motor rated currents, starting currents, and/or longer starting times a
higher-rated fuse has to be applied. This table is also applicable for "gL" fuses (DIN VDE 0636).
Using NH-fuses in aM-characteristics fuse rating = motor rated current has to be selected.
1659
S015004
000919
Fusing of squirrel motors 50 Hz 1500 r. p. m. 30 kW and over
(guide values). For values applicable to contactors and thermal overload relays, see "technical details"
Motor rating
Motor rated current
at 125 V
Fusing
DOL
Y∆
Motor rated current
at 230 V
Fusing
DOL
Y∆
Motor rated current
at 240 V
Fusing
DOL
Y∆
Motor rated current
at 400 V
Fusing
DOL
Y∆
kW
PS ≈ hp
cos ϕ
η%
A
A
A
A
A
A
A
A
A
A
A
A
30
37
40
45
51
55
63
75
80
90
100
110
129
132
140
147
160
180
184
200
220
250
257
270
315
355
400
450
40
50
54
60
70
75
85
100
110
125
136
150
175
180
190
200
220
245
250
270
300
340
350
367
430
483
545
612
0.87
0.87
0.87
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.89
0.89
0.89
90
90
90
91
91
91
91
91
91
92
92
92
92
92
92
93
93
93
93
93
93
93
93
93
93
95
96
96
-
-
-
101
124
134
150
168
181
207
245
260
292
325
358
420
425
449
472
502
578
590
626
700
803
826
867
990
-
125
160
160
200
200
250
250
315
315
400
400
500
500
500
630
630
630
800
800
800
1000
1000
1000
1000
1250
-
125
160
160
160
200
200
200
250
315
315
400
400
500
500
500
630
630
630
630
800
800
1000
1000
1000
1250
-
92,7
114
123
136
154
166
190
226
241
268
297
327
384
393
416
432
471
530
541
589
647
736
756
794
927
-
125
160
160
200
200
200
200
315
315
315
400
400
500
500
500
630
630
630
630
800
800
1000
1000
1000
1250
-
100
125
160
160
200
200
200
250
250
315
400
400
400
500
500
500
630
630
630
630
800
800
800
800
1000
-
60
72
79
85
97
105
119
140
147
170
188
205
242
245
260
273
295
333
340
370
408
460
475
499
580
636
710
800
80
100
100
125
125
160
160
200
200
250
250
250
315
315
315
315
400
400
400
500
500
630
630
630
800
800
1000
1000
63
80
100
100
100
125
125
160
160
200
250
250
250
250
315
315
315
400
400
400
500
500
630
500
630
800
800
1000
Motor rating
kW
30
37
40
45
51
55
63
75
80
90
100
110
129
132
140
147
160
180
184
200
220
250
257
270
315
355
400
450
1660
PS ≈ hp
40
50
54
60
70
75
85
100
110
125
136
150
175
180
190
200
220
245
250
270
300
340
350
367
430
483
545
612
cos ϕ
0.87
0.87
0.87
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.89
0.89
0.89
η%
90
90
90
91
91
91
91
91
91
92
92
92
92
92
92
93
93
93
93
93
93
93
93
93
93
95
96
96
Motor rated current
at 415 V
Fusing
DOL
Y∆
Motor rated current
at 440 V
Fusing
DOL
Y∆
Motor rated current
at 500 V
Fusing
DOL
Y∆
Motor rated current
at 600 V
Fusing
DOL
Y∆
Motor rated current
at 660 V
Fusing
DOL Y∆
A
55
66
80
112,5
135
165
200
230
260
325
385
450
467
-
A
50.1
61.9
67
37.9
83.8
90.3
103.5
123
131
146
162
178
209
214
227
236
256
289
295
321
353
401
412
433
505
549
611
688
A
44
54
60
64.5
73.7
79
90.5
106
112
128
143
156
184
186
200
207
220
254
259
278
310
353
363
381
445
483
538
608
A
37.1
45.4
49.1
54.2
61.4
66.2
76
90.3
96.3
107
119
131
153
157
167
173
188
212
217
325
260
295
302
317
370
405
450
508
A
33
42
49
60
82
98
118
140
170
215
268
337
366
410
460
A
80
100
100
160
200
200
250
315
315
400
500
630
630
-
A
63
80
100
125
160
200
250
250
315
400
400
500
500
-
A
80
80
100
100
125
125
125
160
160
200
200
250
250
250
315
315
315
400
400
400
500
500
500
500
630
800
800
800
A
63
80
80
80
100
100
100
160
160
160
200
200
250
250
250
250
315
315
315
400
400
500
500
500
630
630
800
800
A
63
80
80
100
100
125
125
160
160
160
200
200
250
250
250
250
315
315
315
315
400
500
500
500
630
630
630
800
A
50
63
63
80
80
100
100
125
125
160
160
200
200
200
250
250
250
315
315
315
400
400
400
400
500
630
630
630
A
63
63
80
80
80
100
100
125
125
160
160
160
200
200
200
250
250
250
250
315
315
400
400
400
500
500
630
630
A
50
50
63
63
80
80
80
100
100
125
160
160
200
200
200
200
250
250
250
250
315
315
400
400
400
500
500
630
A
50
63
63
80
125
125
160
200
200
250
315
400
500
500
630
A
35
50
63
63
100
125
125
160
200
250
315
400
400
500
500
S015005
000919
Permissible ratings and protection of PVC-insulated cables and wires
acc. to supplement 1 to DIN VDE 0100 Part 430
Cable and wire
system
Method of installation
No. of wires
NYY, NYCWY, NYKY,
NYM, NYMZ, NYMT,
NYBUY, NHYRUZY
NYM, MYBUY, NHYRUZY, NYIF,
H07V-U, H07V-R, H07V-K, NYIFY
A
conduit-wired in heat
insulating walls
2
3
B1
B2
C
conduit-wired cables (or cable channel)
inside or outside of walls or concealed
E
(single) core cable
multi-core cables
directly
2
2
2
3
3
open air
3
2
3
Recommended values for the permissible rating Iz of cables and wires with Cu-conductors and PVC-insulation,
(operating temperature 70° C) at fixed installation in buildings, continuous operation, ambient temperature
25°C, correspondence of the rated current in In of overcurrent protective gear for protection at overload with
high testing current Iz ≤ 1.45 In to E DIN VDE 0298 Part 4/1996 and DIN VDE 0100 Part 430 supplement 1/01.91
Cross section
Cu-conductor in mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
Iz
16.5
21
28
36
49
65
85
105
126
160
193
223
In
16
20
25
35
40
63
80
100
125
160
160
200
Iz
In
Iz
In
Iz
In
14
19
25
33
45
59
77
94
114
144
174
199
13
16
25
32
40
50
63
80
100
125
160
160
18.5
25
34
43
60
81
107
133
160
204
246
285
16
25
32
40
50
80
100
125
160
200
200
250
16.5
22
30
38
53
72
94
118
142
181
219
253
16
20
25
35
50
63
80
100
125
160
200
250
Iz
16.5
22
30
39
53
72
95
117
-
In
Iz
In
16
15 13
20
20 20
25
28 25
35
35 35
50
50 50
63
65 63
80
82 80
100 101 100
-
Iz
In
Iz
21 20 18,5
28 250
25
37 35
35
49 40
43
67 63
63
90 80
81
119 100 102
146 125 126
-
In
Iz
In
16
25
35
40
63
80
100
125
-
21
29
39
51
70
94
125
154
-
20
25
35
50
63
80
125
125
-
Iz
19,5
27
36
46
64
85
107
134
-
In
16
25
35
40
63
80
100
125
-
For underground laying of cables and wires and for cross sections > 120 mm2 in air, VDE 0298 Part 2 will apply.
Adjustable protection devices (motor controllers, circuit breakers) have to be set to the rated operational current of the wire. Overcurrent protective gear for
which the rated current In does not correspond to the values stipulated in the table, the next lower available rated current has to be selected.
ϑu <> 30° C) acc. to E DIN 0298 Part 4/1996;
Conversion factors for deviating ambient temperatures (ϑ
applicable to the permissible rating Iz
Insulating material
Permissible operating temp.
Ambient temperature °C
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
NR/SR
60° C
PVC
70° C
1.29
1.22
1.15
1.08
1.00
0.91
0.82
0.71
0.58
0.41
-
1.22
1.17
1.12
1.06
1.00
0.94
0.87
0.79
0.71
0.61
0.50
0.35
-
EPR
80° C
VPE
90 ° C
1.18
1.14
1.10
1.05
1.00
0.95
0.89
0.84
0.77
0.71
0.63
0.55
0.45
0.32
-
1.15
1.12
1.08
1.04
1.00
0.96
0.91
0.87
0.82
0.76
0.71
0.65
0.58
0.50
0.41
0.29
Conversion factors
NR/SR = natural rubber or soft rubber, PVC = polyvinyl chloride, EPR = ethylen-propylen-rubber, VPE = vulcanized polyethylene
1661
S015006
000731
Contactors for switching lamps and transformers
Switching of lamps
The table below specifies the number of incandescent and fluorescent lamps that can be switched with one contactor of each size.
Similar tables for mercury-vapor, halogen, and sodium-vapor lamps will be provided on request.
Rated
Operacapacity tional
current
W
A
Rated
voltage
50 Hz
Compen- Permissible number of lamps per pole
sation
ENTRELEC-SCHIELE-contactor, open or enclosed type
capacitor
KL4 DL4K DL5K
DL7K DL11K DL15K DL18K
V
µF
230
-
DL22N DL30N
DL42N DL65N DL90N
DL 110 N
Incandescent lamps
60
0.27
24
45
66
93
129
140
161
229
277
370
433
462
567
100
0.45
230
14
28
40
55
77
84
97
137
166
222
260
277
340
200
0.91
230
7
14
19
27
38
41
48
68
82
109
128
137
168
300
1.36
230
4
9
13
18
25
28
32
45
55
73
86
91
112
500
2.27
230
2
5
7
11
15
16
19
27
33
44
51
55
67
1000
4.5
230
1
2
4
5
7
8
9
13
16
22
26
27
34
2000
9.1
230
-
1
2
2
3
3
4
6
8
10
12
13
16
Electronic incandescent lamps (Dulux EL;
Circolux EL,- SL- bzw. PL-lamps)
9/10
0.054
230
16
16
24
39
46
51
55
79
111
127
150
158
182
11
0.064
239
13
13
20
33
39
43
47
67
93
107
127
133
153
18
0.09
230
9
9
14
24
27
30
33
47
66
76
90
95
109
26
0.125
230
7
7
10
17
20
22
24
34
48
55
65
68
79
32
0.155
230
5
5
8
14
16
18
19
27
38
44
52
55
63
42
0.2
230
4
4
6
11
12
14
15
21
30
34
40
43
49
Fluorescent
uncompensated
Individual circuit
40
0.43
230
41
43
46
67
81
90
113
167
209
279
544
544
606
65
0.7
230
25
26
28
35
50
60
70
102
128
170
334
334
372
100
1.5
230
12
12
13
16
23
25
32
48
60
79
156
156
174
120
1.5
230
12
12
13
15
23
25
32
48
60
79
156
156
174
215
1.5
400
6
7
7.5
10
15
15
18
27
34
38
90
90
100
compensated
40
0.3
230
4.5
20
30
60
90
116
125
145
206
250
330
390
416
510
65
0.45
230
7
14
20
40
60
77
85
97
137
166
220
260
277
340
100
0.7
230
18
9
15
25
40
50
55
62
88
107
142
167
178
218
120
0.8
230
18.5
7
12
22
35
43
46
54
77
93
125
146
156
191
215
0.8
400
10
4
10
12
20
25
28
31
43
53
71
83
90
110
Double circuit
by switching
Number of double units
2 x 40
2 x 0.3
230
30
31
33
40
58
70
81
120
150
198
390
390
435
2 x 65
2 x 0.45
230
20
21
22
30
38
45
54
80
100
132
260
260
290
2 x 100
2 x 0.7
230
12
11
14
20
25
30
35
51
64
85
167
167
186
2 x 120
2 x 0.8
230
11
10
12
18
21
27
30
45
56
74
146
146
163
Switching of transformers (primary)
The transient phenomena associated with the switching of transformers (primary) give rise to making current peaks that can be 20 to 30 times the rated currents.
The table below specifies the making current peaks that the individual types of contactors are able to withstand.
Types
Rating at 400 V AC
DL 4 K
kW
DL 5 K DL 7 K
DL 11 K
DL 15 K
DL 18 K
DL 22 N
DL 30 N DL 42 N
DL 65 N
4
5.5
7.5
11
15
18.5
22
30
42
63
Maximum making current peak (crest value)
A
300
400
700
850
900
1000
1400
1700
2200
2600
Rated current of transformer up to 690 V ≈ Ie
A
8
9
12
15
18
22
30
40
50
80
Single-phase transformer up to max. 440 V ~ Ie
A
8
9
12
15
18
22
30
40
50
80
Notes
The values given in the above tables are values for AC- and DC-operated contactors (economy circuit coils).
Because of the switching behavior and the moved masses, no DL 4 K-DC...DL 5 K-DC contactors should be used in "DC" systems.
DL 7 K-DC, DL 11 K-DC, DL 15 K-DC and DL 18 K-DC can be used as these contacts withstand electrical welding.
Order reference : see contactors. When ordering, add voltage code number to order reference.
Voltage codes: page 1654. Technical details: pages 1664-1665.
1662
S015007
000623
Standards
Utilization categories for contactors to IEC 947-4-1, EN 60 947, DIN VDE 0660 Part 102
Nature of current
Category
Typical applications
Alternating current
AC 1
Non-inductive or slightly inductive loads,
resistance furnaces
AC 2
Starting of slip-ring motors
AC 3
Starting squirrel-cage motors,
switching off of motors while they are running
AC 4
Starting squirrel-cage motors,
inching,
plugging,
reversing
DC-1
Non-inductive or slightly inductive loads,
resistance furnaces
DC-3
Shunt motors :
Starting, plugging, reversing, inching,
dynamic breaking
DC-5
Series motors :
Starting, plugging, reversing, inching,
dynamic breaking
DC-6
Switching of incandescent lamps
Direct current
Utilization categories for auxiliary contact blocks to IEC 947-5-1, EN 60 947, DIN VDE 0660 Part 200
Alternating current
Direct current
AC-12
Control of resistive load and solid-state loads with isolation by optocouplers
AC-13
Control of solid-state loads with transformer isolation
AC-14 (so far AC-11)
Control of small electromagnetic loads (max. 72 VA)
AC-15 (so far AC-11)
Control of electromagnetic loads (higher than 72 VA)
DC-12 (so far DC-11)
Control of resistive load and solid-state loads with isolation by optocouplers
DC-13 (so far DC-11)
Control of electromagnets
DC-14 (so far DC-11)
Control of electromagnetic loads having economy resistors in circuit
Degree of protection of electrical equipment by enclosures and covers acc. to IEC 529, DIN 40 050
1. Code No.
Protection against accidental contact
Protection against foreign bodies
2. Code No.
Protection against water
IP 00
No protection
No protection
No protection
IP 20
Against ingress of fingers
Against foreign bodies > 12 mm Ø
No protection
IP 41
Against ingress of tools and small wires
Against foreign bodies > 1 mm Ø
No damaging effect from dripping water
IP 43
Against ingress of tools and small wires
Against foreign bodies > 1 mm Ø
No damaging effect from spraying water
IP 54
Complete protection
Against internal dust deposit
No damaging effect from splash water
IP 55
Complete protection
Against internal dust deposit
No damaging effect from water jets
IP 65
Complete protection
Dust-tight
No damaging effect from water jets
IP 67
Complete protection
Dust-tight
During immersion water should not penetrate
in damaging amounts
Notes
Protection against accidental contacts acc. to IEC 536, DIN VDE 0106 Part 100
Design of electrical equipment and its arrangement in electrical installations with a rated operational voltage of up to 1000 V ~ and 1500 V ~ in respect to protection
against direct contact, when operating elements (pushbuttons, toggle switches etc.) are close to hazardous parts.
Contact protection "fingerproof" only refers to the operating element in the direction of operation. In this case, a distance from the operating element to hazardous
parts in the radius of r = 30 mm from the central point has to be assured.
The degree of protection IP 20 is more than contact protection "fingerproof." A protection against contacts with electrical equipment from all directions is included.
On request, an extended protection against contact can be achieved for products with contact protection "fingerproof" and degree of protection IP 00, by using
covers.
1663
S015008
000623
Technical details - mini contactors
Technical details
Types
KL 2...
KL 4...
KLW 2...
KLW 4...
Rated
insulation voltage Vi in V
VDE 0110, group C
IEC 947-1, BS 5424, NFC 20-040
CSA 22,2, Nr., 14 UL 508
Rated operational voltage Ve
Rated operational current Ie on AC 1, UC ≤ 440 V ≤ 50° C A
Rated thermal current Ith of auxiliary contacts at ≤ 50° C
Permissible overcurrent
≤ 15 min / 3 min / 1 min A
starting from cold at Θ ≤ 50° C
30 sec / 10 sec / 5 sec
open types
0.5 sec / 1 sec
AC 3 motor rating when
230 V
switching slipring or squirrel cage
400 V
motor on
500 V
50 Hz and 60 Hz, KL 2/Kl 4
690 V
Max. rating related to
S/h
max. switching frequency
Rated breaking capacity I eff
230...415 V
IEC 947, NFC 63-110
500 V
690 V
Rated making capacity I eff, IEC 947, NFC 63-100
Switching
1. Contactors
2. Control relays
times
Making :
at Vc and
- N/C opens
after
20 ° C
- N/O main pole closes - N/O closes
after
Breaking :
- N/O main pole opens - N/O opens
after
- N/C closes
after
Voltage cutoff max.
Switching frequency max.
Mechanical life at Vc
50/60 Hz coils
(millions operations)
standard DC coil
*) KL/KLW
wide range DC coil
Rated operating voltage Vc
Voltage range
operating limits
(at ≤ 50° C) input coil
drop-out value
Power consumption of AC coil at Vc and 20° C
inrush/hold
Power consumption of DC coil
inrush/hold
Power dissipation of the coil
Impedance per pole at Ith and 50 Hz
Terminals capacities
screw terminals
solid conductor
stranded conductor without wire end ferrule
stranded conductor with wire end ferrule
Faston connectors flat blade connector
solder pin connection for p. c. b. main/control circuit unmistakable
Tightening torque
Philips no. 2 and dia, 6
Numbering of aux. contact blocks to EN 50005, EN 50012, EN 50011
Permissible ambient temperature operating
storage
Flame retardency
Shock resistance in normal mounting position
N/O / N/C
vibration resistance 5...300 Hz
Protective treatment to IEC 68/DIN 50 016
Altitude of site of installation without any derating
Protection to VDE 0106
Minimum switching capacity
Vmin (DIN 19 240)
Imin
Non-overlap distance
to INRS, BIA
Forced opening of contacts
Short-circuit protection to IEC 947, VDE 0660, fuses class gL ≤ 440
Mounting position
1)
V
V
V
V
Contactors 2.2...4 kW
KLDC 2...
KLWb 4... KLDC 4...
KLWDC 2...
KLWDC 4...
Hi-Blocks
Pn
A
A
A
A
1
ms
ms
10...20
30...40
30...40
30...40
10...20
30
10
10...20
2
3.600
10/5*)
2
3.600
10/5*)
2
3.600
2
3.600
A
A
A
kW
kW
kW
kW
ms
ms
ms
S/h
Control relays
KH DC...
KHi...
KLi 4...
750
690
690
690
20
10
20/40/45
60/80/85
-/90
1.5/2.2
-/2.2
1.5/2.2
-/2.2
2.2/4
-/4
2.2/4
-/4
3/4
-/4
3/4
-/4
3/4
-/4
3/4
-/4
600
900
1200
100 %
75 %
50 %
110
110
110
110
80
80
80
80
70
70
70
70
110
110
110
110
1
1
1
2
690
10
90/80
2
110
2
5...15
10...20
25...35
30...40
25...35
30...40
10..20
15...25
2
10.000
10
10
15
2
10.000
10...20
15...25
2
6.000
10/5*)
V
20
30
30
~12...690 ~24...230 .... 12...250 .... 12..72 ~12...690 ....12...250 .... 12...72
0.8...1.15 Vc 0.85...1.1 Vc 0.8...1.15 Vc 0.7...1.30 Vc 0.8...1.15 Vc 0.8...1.15 Vc 0.7...1.30 Vc
≥ 0.20 Vc ≥ 0.10 Vc ≥ 0.10 Vc
≥ 0.10 Vc ≥ 0.20 Vc ≥ 0.10 Vc ≥ 0.10 Vc
VA
30/4.5
3/3
1.3
3
30/4.5
W
W
mΩ
mm2
mm2
mm2
mm2
Nm
°C
°C
g
m
V
mA
mm
V
3/3
3
1.8/1.8
1.8
3
Max.
2x4
2x4
1x1.5+1x2.5
1x1.5+1x2.5
Min.
1x1.5
1x0.75
1x0.34
1x0.34
4minx35µ
1.3
3/3
3
1.8/1.8
1.8
Max. to IEC
1x4+1x2.5
2x2.5
1x1.5+1x2.5
1x1.5+1x2.5
0.8
up to 5 aux. contact blocks
0.8
up to 8 aux. contact blocks
-25 ... +50
-50 ... +80
to UL 94, class V-1, self-extinguishing
10/15 g
2/4 g
TC, climatic proof
2000 max.
finger proof
17
5
0.5
yes
25 A
10 A
Min. operational voltage: 0.85 x VC
without restriction
1664
KH S...
1)
1)
S015009
000623
Technical details - contact life of KL 2... and KL 4... mini contactors
Selection of contactors for particular applications
KL 2 ... KL 4 ...
Utilization category AC-1
Switching resistive loads (cos ϕ ≥ 0.95).
On AC-1 the breaking current Ia normally equals
the rated operational current Ie
Example :
Ve = 220 V
Ie = 10 A on AC-1
Θ = 40° C
Ia = Ie = 10 A
Electrical life taken from the curve opposite:
500.000 operations.
million operations
(Ve ≤ 440 V)
Utilization category AC-3
Example :
Asynchronous motor
P = 2.2 kW
Ve = 400 V
Ie = 4.8 A
Ia = Ie = 4.8 A
KL 2 ...
KL 4 ...
million operations
(Ve ≤ 440 V)
Switching squirrel-cage motors.
Switching off during running.
The breaking current Ia equals the
motor rated current.
No. of operations required : 1,000,000
Contactors size to be chosen according
to the curve opposite: KL 2 ...
breaking current A
Utilization category AC-4
(Ve ≤ 440 V)
KL 2 ...
KL 4 ...
Example :
Asynchronous motor
P = 2.2 kW
Ve = 400 V
Ie = 4.8 A
Ia = 6 x Ie = 28.8 A
million operations
Switching squirrel-cage motors.
Switching off during start of motor.
On AC 4 the breaking current Ia is 6 times
the motor rated current Ie.
No. of operations required : 40,000
Contactor size to be chosen according
to the curve opposite: KL 2 ...
Utilization category AC-1
Max. rated operational current related to duty
Duty %
90 %
60 %
30 %
and switching frequency.
300 ops/hr Amp.
13
15
18
120 ops/hr Amp.
15
18
19
30 ops/hr
19
20
20
(Ve ≤ 440 V)
Additional information
Increasing the rated current
by paralleling main poles
Amp.
Amp.
Multiply the above rated currents by the following coefficients (K)
which take into account the often unbalanced current
distribution between poles.
2 poles in parallel K = 1.60
3 poles in parallel K = 2.025
1665
S015010
000623
Technical details - contact life of KH ... mini control relays
Ratings of
auxiliary contacts
AC voltage
(utilization category AC-15)
DC voltage
(utilization category DC-13)
to IEC 947
Electrical life (up to 3.600 ops/hr) at
inductive load in circuits with magnetic
drives :
making capacity (cos ϕ 0.7)
= 10 times the breaking capacity (cos ϕ 0.4).
Electrical life (up to 1.200 ops/hr) at
inductive load in circuits with magnetic
drives, without economy resistor, time
constant of which increases with rating.
at operations ...
*)
1 x 106 operations
3 x 106 operations
10 x 106 operations
Making capacity for
occasional switching
*)
V
VA
VA
VA
VA
24
48
17
7
1000
48
96
34
14
2050
110/
127
240
86
36
5000
220/
230
440
158
66
10000
440
880
317
132
13000
600/
690
1200
500
200
9000
V
W
W
W
W
24
120
55
15
720
48
80
38
11
600
110
60
30
9
400
220
52
28
8
300
Electrical life of contacts
Breaking capacity (VA)
1 Max. duty of
aux. contacts:
50 operations max.
at intervals of 10 secs
(breaking capacity =
making capacity x cos ϕ 0.7)
2 Electrical life of
aux. contacts for :
- 1 million operations (2 a)
- 3 million operations (2 b)
- 10 million operations (2 c)
Additional technical details - page 1664
1666
380/
400
800
288
120
14000
Breaking capacity (W)
3 Max. duty of
aux. contacts:
20 operations max.
at intervals of 10 secs
and current flow time
of 0.5 secs per operation
4 Thermal limit Ith
440
51
26
7
230
600
50
25
6
200
S015011
000919
Technical details - contactors 4...18.5 kW / 5...25 HP at 460 V, 3 ph. / AC 3
Technical details
Types
Rated insulation
voltage Vi
VDE 0110
IEC 947-1, EN 60 947, VDE 0660
CSA 22,2, no. 14, UL 508
Rated operating voltage VC
minimum/maximum
Permissible range of operating voltage
Vc
Rated operational current Ie on AC 1/AC 3 ≤ 40° C
Rated thermal current Ith/Ithe open/enclosed 55°C
Permissible overcurrent
3 min / 1 min
at overload time of
10 secs / 5 secs
(open type)
2 secs / 1 secs
Three-phase power when switching resistive load open/enclosed
on AC 1 at 400 V
Motor rating when switching
230 V
slipring (on AC2) or squirrel cage 400 V
(on AC3) motors
500 V
at 50/60 Hz
690 V
Rated breaking capacity
415 V
at cos ϕ = 0.35
500 V
690 V
Rated making capacity at cos ϕ = 0.35
Switching times at 20° C
Making:
- N/O closes
after
AC
Breaking:
- N/O opens
after
Making:
A = economy circuit coil
- N/O closes
after
DC
B = true DC coil at
Breaking:
-15/+10 % Vc
- N/O opens
after
Switching times for direct change over
of reversing and star-delta contactors (at 110 % Vc)
Power consumption of AC coil inrush/hold
of DC coil (economy circuit coil) inrush/hold
of DC coil (true DC coil) inrush/hold
Impedance per pole
Power dissipation per pole at Ith
Switching frequency - no load operations/hour AC/DC coil
contactor without overload relay
on AC 1
on AC 2
on AC 3
on AC 4
Mechanical life
no. of operations
Electrical life of contacts
Permissible ambient
operating
temperature range
storage
Size of connecting screws/tightening torque - main terminals
Terminal capacities - main and aux. terminals
Mounting position to DIN 40 046 IEC 68
Shock resistance, normal mounting position, half sine shock
shock duration 20 ms
N/O / N/C
Climatic conditions
Weight
Rated operational current Ie
230/400
for auxiliary contacts on AC 15 duty
500/690
Rated thermal current of auxiliary switches Ith/Ithe
Rated insulation voltage of auxiliary switches to VDE 0110 V
Short-circuit protection of contactor without thermal relay type 1 or 22)
Short-circuit protection of auxiliary switches fuse gL/gI
Safety isolation
DL 4 K
DL 4 K-DC
V
V
V
V
750
690
600
12/690
A
A
A
A
A
kW
22/9
22/16
70/80
110/120
160/180
13/10
kW
kW
kW
kW
A
A
A
A
2.2
4
5.5
4
90
90
50
300
DL 5 K
DL 5 K-DC
DL 7 K
DL 7 K-DC
750
690
600
12/690
750
690
600
12/690
0.8...1.1
25/12
39/16
25/20
39/25
70/80
70/80
110/120
220/280
160/180
350/400
16/13
21/16
3
5.5
7.5
5.5
120
120
70
300
4
7.5
11
7.5
220
220
130
600
DL 11 K
DL 15 K
DL 11 K-DC DL 15 K-DC
DL 18 K
DL 18 K-DC
750
690
600
12/690
750
690
600
12/690
750
690
600
12/690
39/23
39/30
70/80
220/280
350/400
26/20
54/30
54/45
120/260
300/450
550/700
36/36
54/37
54/50
120/260
300/450
550/700
36/36
5.5
11.0
15.0
11.0
220
220
130
600
9
15
18.5
15
450
350
250
700
11
18.5
20
18.5
450
350
250
700
ms
12...30
11...20
ms
10...20
5...20
ms
ms
ms
VA
W
W
mΩ
W
A 20...30 / B 65...85
A 10...16 / B 13...14
15...20
15...20
15...20
95/10
95/10
105/1
105/1
6.5
6.5
1.5
1.5
2.5
2.5
10000/1500
A 15...30 / B 65...85
95/10
95/10
105/1
105/1
8.5
8.5
1.5
1.5
2.5
2.5
5000/1500
1500
1000
1000
°C
°C
Nm1)
mm 2
g
kg
A
A
A
690
A
A
M3.5/1.8
M3.5/1.8
0.4
6/4
2/1
16
690
25/20
16
95/10
95/10
105/1
105/1
8.5
8.5
1
1
2
2
3000/1500
750
750
250
10 million
see diagram page 1672
-25° C ... +55° C
-50° C ... +80° C
M3.5/1.8
M3.5/1.8
6/2.5
6/2.5
6/2.5
vertical mounting plane ± 22.5°
6/4
A 10...30 / B 13...18
10...15
10...15
15..20
6/2.5
M3.5/1.8
25/2.5
6/4
6/4
6/4
6/humid warmth, constant, acc. to DIN IEC 68 Part 2-3
humid warmth, cyclic, acc. to DIN IEC 68 Part 2-30
0.4
0.4
0.4
0.62
6/4
6/4
6/4
2/1
2/1
2/1
16
16
16
690
690
25/20
50/35
50/35
100/63
16
16
16
up to 400 V AC to DIN VDE 0106 Part 101
and A1 (draft 2/89) between coil and contact
M4/3
caged terminals
25/2.5
6/-
0.62
100/63
-
Notes
1)
Screws for compact contactors Phillips H2
2)
Short-circuit withstand of contactor without overload relay corresponding to type 2 coordination (No damage to device, except light welding of contacts).
1667
S015012
000731
Technical details - contactors 22...270 kW / 30...400 HP at 460 V, 3 ph. / AC 3
Technical details
Types
Rated insulation
voltage Vi
VDE 0110
IEC 947-1, EN 60 947, VDE 0660
CSA 22,2, Nr. 14 UL 508
minimum/maximum
Rated operating voltage VC
Permissible range of operating voltage Vc
Rated operational current Ie on AC 1/AC 3 ≤ 40° C
Rated thermal current Ith/Ithe open/enclosed 55°C
Permissible overcurrent
3 min / 1 min
at overload time of
10 secs / 5 secs
(open type)
2 secs / 1 secs
Three-phase power when switching resistive load open/enclosed
on AC 1 at 400 V
Motor rating when switching slipring
230 V
(on AC2) or squirrel cage
400 V
(on AC3) motors
500 V
at 50/60 Hz
690 V
Rated breaking capacity
415 V
at cos ϕ 0.35
500 V
690 V
Rated making capacity at cos ϕ = 0,35
Switching times at 20° C
Making:
- N/O closes
after
AC
Breaking:
- N/O opens
after
Making:
A = economy circuit coil
- N/O closes
after
DC
Breaking:
B = true DC coil at -15/+10 %
- N/O opens
after
Switching times for direct change over
of reversing and star-delta contactors (at 110 % Vc)
Power consumption of AC coil inrush/hold
economy circuit coil
true DC coil
Impedance per pole
Power dissipation per pole Ith
Switching frequency - no load operations/hour AC/DC coil
contactor without overload relay
to AC 1
to AC 2
to AC 3
to AC 4
Mechanical life
no. of operations
Electrical life of contacts
Permissible ambient
operating
temperature range
storage
Size of connecting screws/tightening torque - main terminals
Terminal capacities - main and aux. terminals
Mounting position to DIN 40 046 IEC 68
Shock resistance, normal mounting position, half sine shock,
shock duration 20 ms
N/O /N/C
Climatic conditions
V
V
V
V
DL22N DL30N
DL42N
DL65N
DL90N DL110N
750
750
690
690
600
600
12/660 12/660
750
690
600
12/660
750
690
600
12/660
750
750
690
690
600
600
12/660 24/660
0.8...1.1
260/170 290/205
260/230 290/260
600/800 750/1250
1600/1700 1500/1900
1800/2000 2000/2300
191/171 191/171
A
80/44 100/60 130/79 230/119
A
80/75 100/90 130/115 230/200
300/500 500/700
A 200/300 300/500
A 500/600 1000/1200 1000/1200 1300/1500
A 800/1000 1400/1600 1400/1600 1700/1900
kW 53/50 66/59
86/76 171/151
DL132N DL165N
750
750
600
24/660
360/245
360/315
750/1500
2000/2300
2600/2900
237/207
1000
1000
600
80/660
DL245N
DL270N
1000
750
600
80/660
750
690
600
80/660
380/295
500/460
380/340
500/460
1000/1600 2000/2200
2500/3000 3000/3400
3200/3500 3600/4000
250/224 329/303
600/499
600/540
2500/2800
4000/4600
5000/5500
395/355
kW
kW
kW
kW
A
A
A
A
12.5
22
30
30
450
440
330
1000
18.5
30
37
37
800
730
670
1600
22
40
50
55
1000
900
700
1600
37
63
75
75
1200
1200
800
1900
50
90
110
110
1400
1300
1100
2000
60
110
132
160
1700
1600
1500
2300
75
132
160
180
2100
2100
2100
2900
90
160
180
180
2400
2100
2100
3500
115
250
250
270
3700
3100
3100
4000
160
270
345
270
4000
4000
2400
5500
ms
14-19
14-19
11-28
12-20
12-20
12-25
12-25
20-60
20-60
35-110
ms
16-20
16-20
10-15
10-17
10-17
12-18
12-18
20-35
20-35
35-55
ms
10-20
10-20
20-40
20-30
20-30
35-55
35-55
35-65
35-56
50-60
ms
ms
12-18
14-18
12-18
14-18
7-12
11-16
10-14
10-15
10-14
10-15
10-18
21-25
10-18
21-25
18-28
26-33
18-28
26-33
30-60
58-83
430/44
280/6
0.46
31.1
950/77
400/9
0.45
37.9
950/77 1750/88
400/9 1150/11
0.28
0.2
36.3
28.9
2000/1200
VA 146/22 146/22
W 220/2 220/2
W
mΩ
0.8
0.5
W
5.1
5
336/44 430/44
260/6
280/6
0.6
0.46
10.2
31.1
3000/1500
750
750
1000
500
500
250
10 million
see diagram page 1672
-25° C ... +55° C
-50° C ... +80° C
M10
M10
M10
M 12
°C
°C
Nm4) M5/3,5
caged
term.
2
mm
35
M6/4
caged
term.
35
M6/4
caged
term.
35
g
5.5/4
6.5/5.5
5/4
4.5/3.5
4/3
4/3
5/3
humid warmth, constant, acc. to DIN IEC 68 Part 2-3
humid warmth, cyclic, acc. to DIN IEC 68 Part 2-30
2.1
3.2
3.2
9.0
9.0
18
10/6
10/6
10/6
10/6
10/6
10/6
4/2
4/2
4/2
4/2
4/2
4/2
16
16
16
16
16
16
690
690
690
750
750
750
200/160 250/224 315/250 400/355 500/355 630/500
16
16
16
16
16
16
5.5/4
Weight
kg
1.2
1.3
230/400
A
10/6
10/6
Rated operational current Ie
for auxiliary contacts on AC 15 duty
500/690
A
4/2
4/2
A
16
16
Rated thermal current of auxiliary switches Ith /Ithe
Rated insulation voltage of auxiliary VDE 0110
V
690
690
Short-circuit protection of contactor without thermal relay type 1 or 2 3) A 125/100 125/100
Short-circuit protection of auxiliary switches fuse gL/gI
A
16
16
Capacitor contactor on request
120
120
185
185
vertical mounting plane ± 22.5°
1750/88 2500/132
1150/11 1150/11
0.2
0.15
50
54
M12
M12
185
2x150 1)
M12
2x185 2)
5/3
18
30
10/6
10/6
4/2
4/2
16
16
750
750
800/630 800/630
16
16
Notes
1)
Also suitable for 2 x 30 x 5 mm
2)
Also suitable for 2 x 40 x 5 mm
3)
Short-circuit withstand of contactor without overload relay corresponding to type 2 coordination (No damage to device, except light welding of contacts).
4)
Slotted screwdriver up to DL 42 N
1668
3.5/3
S015013
000623
Technical details - K range contactors DLg...,
DC switching
AC/DC operated (economy circuit coil)
Technical details
Rated insulation voltage Vi
Rated thermal current
Rated operational current Ie
with series wiring of main contacts
Types
Ith
Ithe
on DC 1
(L/R ≤ 15 ms)
circuit diagram on
DC 3 + DC 5
Permissible DC load up to 60 V DC, L/R ≤ 5 ms,
single pole version2)
Power consumption (economy circuit coil)1)
Permissible range of operating voltage Vc
Minimum and maximum rated
operating voltages
Switching times at 20° C
Making:
- N/O closes
AC
Breaking:
- N/O opens
Making:
- N/O closes
(economy circuit coil) DC
Breaking:
- N/O opens
Rated thermal current for auxiliary contact Ith/Ithe
Rated operational current Ie
on DC 13 at
on DC 12 at
resistive
load
Maximum cable size for auxiliary contacts
Short-circuit protection of auxiliary switches gL
DLg 4 K
DLg 5 K
DLg 7 K
DLg 11 K
DLg 15 K
DLg 18 K
900
39
30
39
39
39
39
39
8
60
open
enclosed
24 V
110 V
220 V
24 V
110 V
220 V
V
A
A
A
A
A
A
A
A
A
900
22
16
22
22
22
22
22
6
40
900
25
20
25
25
25
25
25
6
40
900
39
25
32
32
32
32
32
8
60
900
54
45
54
54
54
54
54
10
100
900
54
50
54
54
54
54
54
16
100
inrush
hold
W
W
105
1
105
1
105
1
minimum
maximum
V
V
12
220
12
220
105
105
105
1
1
1
0.8...1.25 DC / 0.8...1.1 AC
12
12
12
220
220
220
after
ms
12...30
11...20
after
ms
10...20
5...20
after
ms
20...30
15...30
after
ms
A
A
A
A
A
A
A
mm2
A
24 V
110 V
220 V
24 V
110 V
220 V
10...16
16
10
2
0.75
10
6
1
2.5
16
16
10
2
0.75
10
6
1
2.5
16
12
220
10...30
16
10
2
0.75
10
6
1
2.5
16
16
10
2
0.75
10
6
1
2.5
16
-
-
Notes
1)
Power consumption of AC and true DC coils see page 1667.
2)
Main contacts connected parallel, see accessories on page 1614.
1669
S015014
000623
Technical details - contactors DLg...,
DC switching
AC/DC operated (economy circuit coil)
Technical details
Rated insulation voltage Vi
Rated thermal current
Types
Ith
Ithe
on DC 1
open
enclosed
24 V
Rated operational current Ie
with series wiring of main contacts
110 V
220 V
(L/R ≤ 15 ms) 24 V
circuit
on
110 V
diagram
DC 3 + DC 5 220 V
Permissible DC load up to 60 V DC, L/R ≤ 5 ms,
single pole version2)
Terminal capacities - Main terminals at single pole
switching
Power consumption (economy circuit coil)1)
inrush
hold
Permissible range of operating voltage Vc
Minimum and maximum rated
min.
operating voltages
max.
Switching times at 20° C
Making:
- N/O closes after
AC
Breaking:
- N/O opens after
Making:
- N/O closes after
(economy circuit coil) DC
Breaking:
- N/O opens after
Rated thermal current for auxiliary contact Ith/Ithe
A
Rated operational current Ie
on DC 13 at 24 V
110 V
220 V
on DC 12 at 24 V
resistive
0110 V
load
220 V
Maximum cable size for auxiliary contacts
Short-circuit protection of auxiliary switches gL
DLg22N DLg32N DLg42N DLg65N DLg90N DLg110N DLg132N DLg165N DLg245N DLg270N
V
A
A
A
A
A
A
A
A
A
900
80
75
75
75
75
75
75
12
160
900
100
90
90
90
90
90
90
25
200
900
130
115
115
115
115
115
115
60
240
900
230
200
200
200
200
200
200
90
360
900
260
230
230
230
230
230
230
150
460
900
290
260
260
260
260
260
260
200
500
900
360
315
315
315
315
315
315
200
-
1200
380
340
340
340
340
340
340
250
-
1200
500
460
460
460
460
460
460
300
-
1200
600
540
540
540
540
540
540
350
-
mm 2
70
95
95
150
150
240
-
-
-
-
W
W
186
8
260
6
260
6
280
6
1150
11
1150
11
1320
11
V
V
12
220
12
220
12
220
42
220
42
220
42
220
ms
14-19
11-16
11-28
12-20
12-20
12-25
12-25
20-60
20-60
35-110
ms
16-20
10-15
10-15
10-17
10-17
12-18
12-18
20-35
20-35
35-55
ms
10-20
20-40
20-40
20-30
20-30
35-55
35-55
35-65
35-65
50-60
ms 12-18
16
16
A
10
A
5
A
1
A
10
A
6
A
1
mm2
4
A
16
7-12
16
10
5
1
10
8
1
4
16
7-12
16
10
5
1
10
8
1
4
16
10-14
16
10
5
1
16
8
2
4
16
10-14
16
10
5
1
10
6
2
4
16
10-18
16
10
5
1
16
8
2
4
16
10-18
16
10
5
1
16
8
2
4
16
18-28
16
10
5
1
16
8
2
4
16
18-28
16
10
5
1
16
8
2
4
16
30-60
Notes
1)
Power consumption of AC coils - page 1668
2)
Main contacts connected parallel, see accessories on page 1623.
1670
280
400
400
6
9
9
0.8...1.1 Vc (from warm)
12
12
24
24
220
220
220
220
10
5
1
16
8
2
4
16
S015015
000623
Technical details - control relays and
auxiliary contact blocks
Technical details
Types
Rated insulation
voltage
Vi
B
A
True DC coil
Economy circuit coil
HL 4 K HL 4 K DCHL 8 KHL 8 K DC-
VDE 0110
CSA/UL
IEC 337-1, 947-1
Permissible ambient temperature operating/storage
Power consumption of AC coil inrush/hold
Power consumption of DC coil inrush/hold
(economy circuit coil)
Power consumption of DC coil inrush/hold
(true DC coil)
Operating limits of magnet coil Vc
V
V
V
°C
VA
W
750
600 ac.
690
W
6.5
Rated thermal current Ith/Ithe
Mechanical life
to VDE group E 1 at 3000 ops/hr
Switching frequency
A
ops
65/9
HLg 4 K-
Auxiliary contact blocks
Hi, Li /
S 11, S 20
750
600 ac.
690
-25°C ... to + 55°C / -50°C to +80°C
115/1
750
600 ac.
690
-
AC
0.8...1.1
DC
0.8...1.25
2.5
2.5
2.5
Terminal capacities
(solid, stranded conductor)
mm 2
Connecting screw / tightening torque
Nm
M3.5/1.2
M3.5/1.2
M3.5/1.1
Shock resistance (half-sine wave, shock duration 20 ms) N/O / N/C g
6
6
6
Switching times at 20°C
Making:
- N/C opens
after
ms
7...14
7...14
- N/O closes
after
ms
10...23
10...23
12...30
AC coils
Breaking:
- N/O opens
after
ms
16...35
16...35
10...20
- N/C closes
after
ms
17...38
Making:
Vnom: -15% ......... +10%1
67 ......... 50
A = economy circuit coil
- N/C opens
after
ms
7...14
85 ......... 65
- N/O closes
after
ms
10...23
A 20...30
DC coils
B = true DC coil
Breaking:
Vnom: -15% ......... +10%
13 ......... 14
at -15 / +10 %
- N/O opens
after
16...35
A 10...16
25 ......... 22
- N/C closes
after
ms
17...38
Mounting position to DIN 40 046 IEC 68 vertical mounting plane
± 22.5°
± 22.5°
± 22.5°
Climatic conditions
Control relays are climatic proof to IEC 68, Part 2-3, Part 2-30
Rated operating voltage Vc
V
12...660
12...660
12...660 V
Rated operational current Ie
AC voltage
230 V
A
6
6
6
on AC 15
400 V
A
4
4
4
500 V
A
2
2
2
690 V
A
1
1
1
DC voltage
24 V
A
10
10
10
on DC 13
110 V
A
2
2
2
L/R = 15 ms
220 V
A
0.75
0.75
0.75
resistive load
24 V
A
10
10
10
on DC 12
110 V
A
6
6
4
L/R=<1ms
220 V
A
1
1
1
operations
at nominal rating
ops/
on AC 15 / DC 13
hr
no-load operations AC/DC
ops/hr
Short-circuit protection
slow type gL
A
Safety isolation of coil and contacts to VDE 0106 Part 101 and A1 (draft 2/89)
16
3x107
16
3x107
10/16
3x107
1200
1200
1200
10000/1500
16
10000/1500
16
10000
16
Note: 1Nominal coil voltage -15% to +10%
1671
S015016D 000623
Technical details - contact life
Electrical life
on AC 2 to AC 4
VDE 0660, Part 102
Applicable to contactor types DL 4 K to DL 270 N
Typical values:
Electrical life of a contactor is determined, to a large extent, by the
breaking current of the load. The characteristic curves, opposite,
represent electrical life in relation to the breaking current. Up to 6
times the starting and breaking current should be taken into
account when selecting a contactor (see example).
Example: DL 22 N
Three-phase motor 22 kW
rated operational current 44 A
= max. breaking current on AC 3
Electrical life
106 operations
Three-phase motor 22 kW
6 times rated operational current
6 x 44 A = 264 A
= max. breaking current on AC 4
Electrical life
5 x 104 operations
PN =
Electrical life
Utilization category
100 % AC 1 - VDE 0660, Part 102-4.3.6
switching resistive loads (cos ϕ 0.95)
e.g., resistance furnaces
Max. AC 1 ratings for enclosed contactors
have to be reduced as follows:
DL 4 K / DL 5 K
DL 22 N to DL 110 N
DL 132 N
DL 165 N to DL 270 N
1672
75
90
85
90
%
%
%
%
Rating of
3-phase squirrel
cage motor
IA = Breaking current
Ie = Rated operational
current
S015017
000919
Dimensions - KH / KL, KLW and accessories
KH... control relays with HS / HF aux. contact block attached
Base mount
To 35 mm mounting rail (DIN 50 022)
HV-48, HV-240 timer modules
KL 2, KL 4... contactors
with HS, HF, LS aux. contact block attached
KLW 2, KLW 4... reversing contactors
with HS, HF, LS aux. contact block attached
Base mount
To 35 mm mounting rail (AM 1-DP 200 or AM 1-DE 200) DIN 50 022
To 35 mm mounting rail (AM 1-DP 200 or AM 1-DE 200) DIN 50 022
Mounting on printed circuit board
Mounting reversing contactors or 2 contactors side by side on printed circuit board
1673
S015018
000919
Dimensions - HL 4 K / HLg 4 K / HL 8 K / DL 4 K...DL 18 K...
reversing and star-delta contactors
AC-version or DC-version with economy circuit coil
HL 4 K control relay
HLg 4 K control relay
HL 8 K control relay (HL 4 K + aux. contact: H = 120 mm)
Dimension H :
120 mm with aux. contact
125 mm with latch head
137 mm with timer
127 mm with aux. contact with plunger
Contactors DL 4 K...-DL 11 K, DLg 4 K..-DLg 11 K, DLW 4 K...DLW 18 K, with M 23 K thermal relay attached
Dimension H :
120 mm with aux. contact
125 mm with latch head
137 mm with timer
127 mm with aux. contact with plunger
Dimension B :
with 2 side mounted aux. contact blocks = 68+1
Dimension L :
with relay interface module RM-K
Contactors DL 15 K...DL 18 K, DLg 15 K...DLg 18 K, star-delta contactors DLDAe 7,5 K...DLDAe 30 K, with M 40 K thermal relay attached
Type :
Dimension H :
132 mm with aux. contact
139 mm with latch head
150 mm with timer
139 mm with aux. contact with plunger
1674
Dimension B :
with 2 side mounted aux. contact blocks = 68+1
Dimension L :
with relay interface module RM-K
DLDAe 7.5 K
12.5 K
15 K
18.5 K
22 K
30 K
supply
voltage
4K
7K
7K
15 K
15 K
15 K
∆
4K
7K
7K
11 K
15 K
15 K
Y
4K
4K
5K
7K
7K
11 K
S015019
000623
Dimensions - DL 4 K DC...DL 18 K DC, HL 4 K DC
DL 4 K DC..., DL 11 K DC... + M 23 K
HL 4 K DC, HL 8 K DC
Dimension H :
159 mm with aux. contact
166 mm with aux. contact with plunger
166 mm with latch head
177 mm with timer
with module = 106 mm high
DL 15 K DC / DL 18 K DC + M 40 K
Dimension H :
171 mm with aux. contact
178 mm with aux. contact with plunger
178 mm with latch head
189 mm with timer
with module = 106 mm high
1675
S015020
000731
Dimensions - DL 22 N...DL 42 N, DLDAe 37 N...DLDAe 65 N,
DLW 22 N...DLW 42 N
2
1
3
Single contactors 1
Reversing contactors 2
DL 22 N + M 80 N
Star-delta contactors 3
Supply voltage
∆
Y
DLDAe 37 N + M 80 N
DL 22 N
DL 22 N
DL 15 K
DLg 22 N + M 80 N
DLW 22 N + M 80 N
DLDAe 45 N + M 80 N
DL 22 N
DL 22 N
DL 18 K
DL 30 N + M 80 N
DLW 30 N + M 80 N
DLDAe 55 N + M 80 N
DL 30 N
DL 30 N
DL 18 K
1
2
3
Single contactors 1
Reversing contactors 2
Star-delta contactors 3
A
Supply voltage
∆
Y
DLW 42 N + M 80 N
DLDAe 65 N + M 80 N
99
DL 42 N
DL 42 N
DL 22 N
DL 42 N + M 80 N
DLg42 N + M 80 N
1676
S015021
000623
Dimensions - DL 65 N, DL 110 N, DLDAe 110 N...250 N,
DLW 65 N...DL 90 N
2
1
3
Single contactors 1
Reversing contactors 2
DL 65 N + M-b 177 S, DL 90 N + M-b 177 S
DLW 65 N + M-b 177 S
DLg 65 N + M-b 177 S, DLg 90 N + M-b 177 S
Star-delta contactors 3
Supply voltage ∆
Y
A
B
C
D
E
DLDAe 75 N
65 N
32 N
22 N 118 99
-
-
-
DLDAe 110 N
65 N
65 N
42 N 127 118
-
-
-
DLDAe 160 N
90 N
90 N
65 N 128 127
62
M 12 37
+ M-b 177 S
Dimensions
2
1
Single contactors 1
Star-delta contactors 2
Supply voltage
∆
Y
DL 110 N + M-bw 207
DLDAe 200 N + M-bw 320 S
DL 110 N
DL 110 N
DL 65 N
DL 132 N + M-b 177 S + M-bw 320 S
DLDAe 250 N + M-bw 320 S
DL 132 N
DL 132 N
DL65 N
1677
S015022
000623
Dimensions - DL 165 N...270 N, DLDAe 360 N...500 N
2
1
Single contactors 1
Star-delta contactors 2
Supply voltage
∆
Y
DL 165 N + M-b 177 S, DL 165 N + M-bw 320 S
DLDAe 360 N + M-b 721 Sw
DL 245 N
DL 245 N
DL 110 N
DL 245 N + M-b 721 Sw
DLg 165 N, DLg 245 N
1
2
Single contactors 1
Star-delta contactors 2
Supply voltage
∆
Y
DL 270 N + M-b 721 Sw, DL 270 N + M-bw 320 S
DLDAe 500 N + M-b 721 Sw
DL 270 N
DL 270 N
DL 165 N
DL 270 N
1678