+TCCM Tower Relocation Permit Set
Transcription
+TCCM Tower Relocation Permit Set
RIM TCCM TOWER RELOCATION PERMIT SET A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 2015.03.31 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION RENDERINGS VICINITY MAP DRAWING INDEX GENERAL G001 G002 COVER SHEET GENERAL NOTES & CONDITIONS OF APPROVAL ARCHITECTURAL SITE AS100 SITE PLAN LANDSCAPE RHAA 225 MILLER AVENUE MILL VALLEY, CA 94941 415.383.7900 CONTACT: MEGHAN SHARP DIECCHIO [email protected] PROJECT DATA: BLOCK: LOT #: ADDRESS: LEGAL JURISDICTION: CONSTRUCTION TYPE: SPRINKLER SYSTEM: BUILDING OCCUPANCY: NEW TOWER AREA: PLUMBING MK2 5030 BUSINESS CENTER DRIVE, SUITE 150 FAIRFIELD, CA 94534 707.307.1500 CONTACT: MIKE KIANI [email protected] 13 MADERA GARDENS SUBDIVISION 74 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 TOWN OF CORTE MADERA, CA TYPE V-1HR (EXISTING) FULLY SPRINKLERED M - MERCANTILE 207 SF 1 APPLICABLE CODES: 1 ALL CONSTRUCTION, REGARDLESS OF DETAILS ON PLANS, SHALL COMPLY WITH THE APPLICABLE SECTIONS OF THE: 2013 CALIFORNIA BUILDING CODE 2013 CALIFORNIA PLUMBING CODE 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA MECHANICAL CODE 2013 CALIFORNIA BUILDING ENERGY STANDARDS DEFERRED SUBMITTALS 1. 2. FIRE SPRINKLERS STOREFRONTS - INDIVIDUAL TENANTS TO SUBMIT SEPARATE PERMIT STRUCTURAL S0.1 GENERAL NOTES AND SPECIFICATIONS S0.2 GENERAL NOTES AND SPECIFICATIONS S1.1 TYPICAL CONCRETE DETAILS S1.2 TYPICAL WOOD DETAILS S1.3 TYPICAL METAL STUD ELEVATION AND CONNECTION DETAILS S1.4 TYPICAL METAL STUD SOFFIT AND MISCELLANEOUS DETAILS S2.1 FOUNDATION PLAN S2.2 ROOF FRAMING PLAN S2.3 TOP OF PARAPET FRAMING PLAN S3.1 CLOCK TOWER ELEVATION AND FRAMING PLANS S4.1 FOUNDATION DETAILS S4.2 FOUNDATION DETAILS S5.1 STEEL FRAMING DETAILS S5.2 STEEL FRAMING DETAILS S5.3 MOMENT FRAME DETAILS S6.1 WOOD DETAILS S7.1 MISCELLANEOUS DETAILS S7.2 MISCELLANEOUS DETAILS PLUMBING P0.1 P2.2 P6.1 P4.1 COVER SHEET ROOF PLAN - PLUMBING DETAILS - PLUMBING TOWER TOP FLOOR PLAN - PLUMBING ELECTRICAL E0.1 ELECTRICAL COVER SHEET E2.1 FIRST FLOOR - LIGHTING AND POWER PLAN E2.2 ROOF LEVEL - LIGHTING PLAN E3.1 ELEVATIONS - LIGHTING AND POWER E4.1 MAINTENANCE LEVEL AND TOWER TOP LEVEL FLOOR PLAN - POWER PLAN, EXISTING ROOF AT TOWER FLOOR PLAN - LIGHTING AND POWER PLAN E5.1 SINGLE-LINE DIAGRAM AND SCHEDULES E6.1 DETAILS - ELECTRICAL E-7.1 TITLE 24 COMPLIANCE 1 COVER SHEET MK2 5030 BUSINESS CENTER DRIVE, SUITE 150 FAIRFIELD, CA 94534 707.307.1500 CONTACT: DEBORAH GARANT [email protected] THIS PROJECT'S SCOPE INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: A. DEMOLITION OF THE EXISTING CLOCK TOWER B. CONSTRUCTION OF NEW CLOCK TOWER C. DEMOLITION OF EXISTING ELEPHANT FOUNTAIN D. MODIFICATIONS TO A PORTION OF EXISTING BUILDING FACADES E. UPGRADES TO BUILDING STRUCTURE F. NEW PLANTERS AND TRELLIS AT ROOF LEVEL G. ELECTRICAL AND LIGHTING MODIFICATIONS FOR RETAIL FACADES AND TOWER H. NO MECHANICAL WORK IS INCLUDED IN THIS SCOPE OF WORK I. FIRE SPRINKLER MODIFICATIONS FOR FACADES & VACANT TENANT SPACES IMPACTED BY THE WORK TO MAINTAIN CODE COMPLIANCE. J. PLANNING DEPARTMENT RESOLUTION: # 43/2014 NOTE: ELEPHANT FOUNTAIN PROJECT IS BEING PERMITTED AS A SEPARATE PROJECT SHEET TITLE: ELECTRICAL PROJECT DESCRIPTION: 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION ZFA 100 BUSH STREET SUITE 1850 SAN FRANCISCO, CA 94104 415.246.4091 CONTACT: NICK REID [email protected] OWNER: STRUCTURAL TOWN CENTER CORTE MADERA, CORTE MADERA, CA 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 RIM ARCHITECTS 300 CALIFORNIA STREET, SUITE 220 SAN FRANCISCO, CA 94104 415.247.0400 CONTACT: MICHELLE JONES [email protected] PERMIT SET ADDRESS: ARCHITECT ARCHITECTURAL A001 ABBREVIATIONS AND SYMBOLS LEGEND AD101 DEMOLITION FLOOR PLAN AD102 DEMOLITION ROOF PLAN A101 FIRST FLOOR PLAN A102 NEW ROOF PLAN A103 TOWER FLOOR PLANS A104 TOWER FLOOR PLANS A105 ENLARGED TOWER ROOF PLAN A201 EXTERIOR ELEVATIONS A202 TOWER ELEVATIONS A203 TOWER ELEVATIONS A204 TOWER SECTIONS AND ELEVATION A205 WALL SECTIONS AND ENLARGED BAY ELEVATION/PLAN A206 WALL SECTIONS AND ENLARGED BAY ELEVATION/PLAN A301 BUILDING SECTION A A501 DETAILS A502 DETAILS A503 DETAILS A601 EXTERIOR FINISH AND HARDWARE SCHEDULE TCCM TOWER RELOCATION A R C H I T E C T S PLANTERS DETAILS IRRIGATION AND DRAINAGE PLANS IRRIGATION DETAILS PLANTING PLAN AND DETAILS PROJECT TITLE: RIM LANDSCAPE L1.0 L2.0 L2.1 L3.0 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MMJ 2015 RIM ARCHITECTS LLC DWG NO: G001 SHEET GENERAL NOTES RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com NO DESCRIPTION GENERAL NOTES & CONDITIONS OF APPROVAL SHEET TITLE: 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION OWNER: ADDRESS: 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 PERMIT SET TCCM TOWER RELOCATION 1. DO NOT DISASSEMBLE THIS SET. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. IN THE EVENT OF CONFLICT OR DISCREPANCIES IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING PRIOR TO PROCEEDING. 2. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING AND THE MAJOR ARCHITECTURAL ELEMENTS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. DECISIONS OF THE ARCHITECT AS TO THE ITEMS OF THE WORK INCLUDED WITHIN THE SCOPE OF THIS DOCUMENT SHALL BE FINAL AND BINDING TO THE CONTRACTOR. 3. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN APPROVED BY THE ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND SAMPLES. THE USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS BY ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR, OR MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFIES HIS ACCEPTANCE OF ALL INFORMATION SHOWN HEREIN AS CORRECT AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY OCCUR. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE STANDARDS OF BEST PRACTICE BY WORKERS SKILLED IN THEIR RESPECTIVE TRADES. FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH A SMOOTH, CLEAN UNIFORM APPEARANCE. APPROVED ALTERNATES OR SUBSTITUTIONS SHALL BE EQUAL TO WORK OF SIMILAR TYPE, CHARACTER AND MATERIAL SPECIFIED IN THE CONSTRUCTION DOCUMENTS AND MUST BE APPROVED IN ADVANCE BY THE ARCHITECT AND THE OWNER. 5. ALL WORK SHALL CONFORM TO THE REQUIREMENTS IN THE STATE OF CALIFORNIA AND APPLICABLE REGULATORY AGENCIES. ALL WORK SHALL CONFORM TO THE LATEST EDITIONS OF THE CBC & APPLICABLE CODES, INDICATED ON THE COVER SHEET. 6. THE AMERICANS WITH DISABILITIES ACT (ADA) IS SUBJECT TO VARIOUS AND POSSIBLY CONTRADICTORY INTERPRETATIONS. THESE PLANS AND ANY ACCOMPANYING SPECIFICATIONS REPRESENT DESIGNER'S OPINION REGARDING ITS INTERPRETATION OF THE ADA AS IT APPLIES TO THE SUBJECT PROJECT. ANY VARIANCE FROM THESE DOCUMENTS MAY CREATE NON-COMPLIANCE TO THE ACT. 7. DURING THE DURATION OF THE PROJECT, CONTRACTOR SHALL PROVIDE PROTECTION FROM INCLEMENT WEATHER OF ALL SURFACES AND MATERIALS IN ORDER TO KEEP THEIR CONDITION FREE FROM INJURY OR DAMAGE. 8. ALL WORK SHALL BE IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, INCLUDING THE PROJECT MANUAL, SPECIFICATIONS, ADDENDA, ANY MODIFICATIONS ISSUED BY THE ARCHITECT OR AS DIRECTED BY OWNER. 9. DO NOT SCALE DRAWINGS. 10. COLUMN GRID LINES ARE SHOWN FOR REFERENCE ONLY. 11. FEATURES OF CONSTRUCTION NOT FULLY SHOWN SHALL BE OF THE SAME CHARACTER AS SHOWN FOR SIMILAR CONDITIONS. 12. CONTRACTOR TO COORDINATE WITH OWNER IN REGARD TO SITE ACCESS ROUTE AND SCHEDULING OF MATERIAL DELIVERIES TO THE SITE. 13. PROTECT AREA FROM DAMAGE WHICH MAY OCCUR FROM DEMOLITION, DUST, WATER, ADVERSE WEATHER, ETC. PROVIDE & MAINTAIN TEMPORARY BARRICADES, CLOSURE WALLS, ETC. AS REQUIRED TO PROTECT THE PUBLIC & ADJACENT EXISTING STRUCTURES DURING THE PERIOD OF CONSTRUCTION. DAMAGE TO EXISTING STRUCTURES & EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER. 14. DEBRIS FROM DEMOLITION SHALL BE COLLATED AND REMOVED ON A DAILY BASIS. ROUTING OF ANY DEBRIS THROUGH ANY PORTION OF THE EXISTING BUILDING SHALL BE AS DESIGNATED BY THE OWNER. 15. ALL INFORMATION PROVIDED IN THE DOCUMENTS IS DONE SO WITH THE BEST KNOWLEDGE OF EXISTING CONDITIONS. 16. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURE AND FOR ALL SAFETY PROGRAMS AND PRECAUTIONS IN CONNECTION WITH THE PROJECT. NEITHER THE OWNER NOR THE ARCHITECT IS RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO FOLLOW PROPER SAFETY PROCEDURES PROJECT TITLE: CONDITIONS OF APPROVAL DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MJ 2015 RIM ARCHITECTS LLC DWG NO: G002 SHEET RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com MADERA BLVD. 5 CB CB M CB CB M M M M MH M UB 5 MH CB CB MH V V V V CB CB CB CB CB M M CB CB CB 5 CB M CB CB CB 5 UB CB CB 5 UB UB M M M M V CB CB FH M CB M M V CB CB CB 5 CB MH CB M M M MH 5 CB 5 CB CB CB CB M M 5 CB 5 M CB M MH V CB 5 AREA OF WORK 5 PERMIT SET 5 CB CB M CB 5 TAMALPAIS BLVD. FH CB CB MH MH CB CB CB MH PIPES PIPES CB M MH UB CB M MH M MH MH MH M M MH UB CB FH UB MH MH MH V 5 V V M M M UB M 5 CB V M CB M 5 M CB CB CB CB MH MH MH V MH MH CB MH CB OWNER: PROJECT TITLE: 5 UB V SHEET TITLE: CB UB M ADDRESS: UB M V FH UB 5 SITE PLAN CB UB CB 5 5 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION FH FOUNTAIN MH M CB 5 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 CB 5 TCCM TOWER RELOCATION M M M M M MM MH 5 CB CB CB M M CB CB 5 CB 5 5 CB 5 CB M CB M M M CB CB 5 CB 5 CB CB CB 5 CB UB UB M 5 NO DESCRIPTION DATE REVISIONS PLAN NORTH 1 AS100 SITE PLAN 1/64" = 1'-0" DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MJ 2015 RIM ARCHITECTS LLC DWG NO: AS100 SHEET MATERIALS LEGEND CAB CB CEM CER CFCI CG CMPST CI CIP CJ CL CLG CLO CLR CMU CNTR CO COL CONC COND CONN CONSTR CONT CONTR COORD COP CORR CPT CSK CT CTR CUH CULT CW CABINET CATCH BASIN CEMENT CERAMIC CONTRACTOR FURNISHED CONTRACTOR INSTALLED CORNER GUARD COMPOSITE CAST IRON CAST IN PLACE CONTROL JOINT CENTER LINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT COUNTER CLEAN OUT COLUMN CONCRETE CONDITION CONNECTION CONSTRUCTION CONTINUE/CONTINUOUS CONTRACTOR COORDINATE COPPER CORRIDOR CARPET COUNTERSINK CERAMIC TILE CENTER CABINET UNIT HEATER CULTURED COLD WATER PIPING D D DBL DEG DEPT DET DF DIA DIAG DIM DISP DN DR DS DSP DW DWG DWR DEEP/DEPTH DOUBLE DEGREE DEPARTMENT DETAIL DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DISPENSER DOWN DOOR DOWNSPOUT DRY STANDPIPE DISHWASHER DRAWING DRAWER FGL FH FHC FIN FIN GR FIXT FLDG FLG FLR FLUOR FLR SK FOC FOF FOM FOS FOW FP FR FRP FRT FRZ FT FTD FTG FURG FUT G GA GALV GB GEN GFGI GFRG GFRC GL GLU LAM GPM GRAN GSB GTV GWT GYP GWB FAHRENHEIT FIRE ALARM FABRICATE FLAT BAR FAN COIL UNIT FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FURNITURE, FIXTURES AND EQUIPMENT FIBERGLASS FIRE HYDRANT FIRE HOSE CABINET FINISH FINISH GRADE FIXTURE FOLDING FLOORING FLOOR FLUORESCENT FLOOR SINK FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FACE OF WALL FIRE PROOF FRAME FIBERGLASS REINFORCED PLASTIC FIRE RETARDANT FREEZER FEET FACIAL TISSUE DISPENSER FOOTING FURRING FUTURE G NATURAL GAS GAUGE GALVANIZED GRAB BAR GENERAL GOVERNMENT FURNISHED /GOVERNMENT INSTALLED GLASSFIBER REINFORCED GYPSUM GLASSFIBER REINFORCED CONCRETE GLASS/GLAZING GLUE LAMINATED WOOD GALLONS PER MINUTE GRANITE GYPSUM SHEATHING BOARD GATE VALVE GLAZED WALL TILE GYPSUM GYPSUM WALL BOARD H H HB HC HCP HD HIGH HOSE BIBB HOLLOW CORE HANDICAPPED HEAD ID INCL IMP IN INFO INSUL INT INV INSIDE DIAMETER INCLUDED INSULATED METAL PANEL INCH INFORMATION INSULATION/INSULATED INTERIOR INVERT J J-BOX JAN JST JT JUNCTION BOX JANITOR JOIST JOINT K KD KIT KO KW KWH KNOCK DOWN KITCHEN KNOCK-OUT KILOWATT KILOWATT HOUR L L LAB LAM LAV LB LBF/SF LDG LF LH LKR LLV LOC LT LR LVR LENGTH LABORATORY LAMINATE LAVATORY POUND POUNDS PER SQUARE FOOT LANDING LINEAR FOOT LEFT HAND LOCKER LONG LEG VERTICAL LOCATION LIGHT LIVING ROOM LOUVER M M M2 MATL MAX MB MBR MC MECH MEMB MEZZ MFR MH MI MID MIN MISC MLDG MM MO MOD MP MR MTD MTL MTG MULL MUN MW METER SQUARE METERS MATERIAL MAXIMUM MACHINE BOLT MASTER BEDROOM MEDICINE CABINET MECHANICAL MEMBRANE MEZZANINE MANUFACTURER MANHOLE MIRROR MIDDLE MINIMUM MISCELLANEOUS MOULDING MILLIMETER MASONRY OPENING MODULE METAL PANEL MOISTURE RESISTANT MOUNTED METAL MOUNTING MULLION MUNTIN MICROWAVE N N NFS NIC NO NOM NTS NORTH NON-FROST SUSCEPTIBLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OFD OH OPH OPNG OPP OPR OVHD PA PC PCC PEND PERIM PH PLAS PLBG PL PLAM PLYWD PNL PR PROP PREFAB PT PTD PTDR PTN PTR PVC PVMT P PUBLIC ACCESS PIECE PRECAST CONCRETE PENDANT PERIMETER PENTHOUSE PLASTER PLUMBING PROPERTY LINE PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PREFABRICATE PAINT PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER AND RECEPTACLE PARTITION PAPER TOWEL RECEPTACLE POLYVINYL CHLORIDE PAVEMENT Q QT QUARRY TILE R R RA RB RB HK RCP RD REC REF REFL REG REINF RECS REQD RESIL REST REV RTF RFG RLG RH RND RM RO RWL R RISER RADIUS RETURN AIR RUBBER BASE ROBE HOOK REFLECTED CEILING PLAN ROOF DRAIN RECESSED REFRIGERATOR REFLECTED REGISTER REINFORCE RECOMMENDATIONS REQUIRED RESILIENT REST ROOM REVISION RUBBER TILE FLOOR ROOFING RAILING RIGHT HAND ROUND ROOM ROUGH OPENING RAIN WATER LEADER S S SA SAB SB SC SCHED SCD SCP SCR SCRN SD SECT SED SF SHT SHR SHTHG SHV SIM SL SLDG SOUTH SUPPLY AIR SOUND ATTENUATION BLANKET SPLASH BLOCK SOLID CORE SCHEDULE SEAT COVER DISPENSER SCUPPER SHOWER CURTAIN ROD SCREEN SMOKE DETECTOR SECTION SEE ELECTRICAL DRAWINGS SQUARE FEET SHEET SHOWER SHEATHING SHELVING SIMILAR SLOPE SLIDING SPC SPEC SPKLR SPKR SQ SSD DRAWINGS SST SMD DRAWINGS SMLS SS STA STD STL STOR STR STRUCT SURR SUSP SVCE SW SYMM SYS CONCRETE A R C H I T E C T S STAINLESS STEEL SEE MECHANICAL SEAMLESS SOLID SURFACE STATION STANDARD STEEL STORAGE STRINGERS STRUCTURAL SURROUND SUSPENDED SERVICE SWITCH SYMMETRICAL SYSTEM TREAD TOWEL BAR TO BE DETERMINED TRENCH DRAIN TELEPHONE TEMPERATURE TERRAZZO TONGUE AND GROOVE THRESHOLD THROUGH THICKNESS TACK BOARD TEMPERED TOP OF CURB TOP OF MASONRY TOP OF PARAPET TOP OF SLAB TOP OF WALL TOILET PAPER DISPENSER TOILET PAPER HOLDER TUBE STEEL TOWEL SHELF THERMOSTAT TELEVISION TYPICAL TOILET U UBC UC UNGD UH UL UNFIN UNO UR UNIFORM BUILDING CODE UNDERCUT UNDERGROUND UNIT HEATER UNDERWRITERS LABORATORY UNFINISHED UNLESS OTHERWISE NOTED URINAL V VAR VB VCT VERT VEST VOL VP VTR VWC W W/ WC WCLR WD WDSP WDW WF WGL WH W/O WP WR WSCT WSP WT WWF VARIES VALVE BOX VINYL COMPOSITION TILE VERTICAL VESTIBULE VOLUME VENEER PLASTER VENT THROUGH ROOF VINYL WALL COVERING W WIDE WITH WALL COVERING WATER COOLER WOOD WASTE DISPOSER WINDOW WIDE FLANGE WIRED GLASS WATER HEATER WITHOUT WATERPROOF/ WATERPROOFING WATER REPELLENT WAINSCOT WET STAND PIPE WEIGHT WELDED WIRE FABRIC SAND, MORTAR, PLASTER, TILE BACKER BOARD CLASSIFIED COMPACTED FILL EARTH, UNCLASSIFIED FILL BATT INSULATION FINISHED WOOD RIGID INSULATION METAL CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com PLYWOOD/MDF GLASS GYPSUM WALL BOARD CERAMIC TILE, VCT OR RESILIENT FLOORING ACOUSTICAL TILE CARPET T T TB TBD TD TEL TEMP TER T&G THRES THRU THK TK BD TMPD TOC TOM TOP TOS TOW TPD TPH TS TSH TSTAT TV TYP TLT RIM CMU PROJECT SPECIFIC ABBREVIATIONS TCCM PERMIT SET TOWN CENTER CORTE MADERA SYMBOLS LEGEND ROOM NAME ROOM DESIGNATION XXx WALL TYPE DOOR DESIGNATION XX GRIDLINE RM NO XXXX X'XX" AFF 1 CEILING HEIGHT DESIGNATION EXTERIOR ELEVATION DESIGNATION A101 SIM XXXX DET_NO EQUIPMENT DESIGNATION DETAIL DESIGNATION SHT_NO SIM XX DET_NO OPENING DESIGNATION BUILDING SECTION DESIGNATION SHT_NO ABBREVIATIONS AND SYMBOLS LEGEND C F FA FAB FB FCU FD FDTN FE FEC FF FF & E I OF/OI SNDU SEALANT SHEET METAL SANITARY NAPKIN DISPENSER SANITARY NAPKIN DISPOSAL UNIT SPACING SPECIFICATION SPRINKLER SPEAKER SQUARE SEE STRUCTURAL SHEET TITLE: BARBEQUE BOARD BELOW FINISH FLOOR BACK BOARD BUILDING BLOCK BLOCKING BEAM BOTTOM OF DECK BOTTOM FACE BOTTOM BEDROOM BEARING BRACKET BASEMENT BETWEEN BUILT-UP ROOFING ES EQ EQUIP EOS EWC EXH EXP EXPN EXT (E) HW HWR HWS OA OBS OC OD OF/CI SLNT SM SND 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION BBQ BD BFF BKBD BLDG BLK BLKG BM BOD BOT F BOT BR BRG BRKT BSMT BTWN BUR EJ EL ELAST ELEC ELEV EMER ENCL EPB EPDM EAST EACH EXTERIOR INSULATION FINISH SYSTEM EXPANSION JOINT ELEVATION ELASTOMERIC ELECTRICAL ELEVATOR EMERGENCY ENCLOSURE ELECTRICAL PANEL BOARD ETHYLENE PROPYLENE DIENE MONOMER EACH SIDE EQUAL EQUIPMENT EDGE OF SLAB ELECTRIC WATER COOLER EXHAUST EXPOSED EXPANSION EXTERIOR EXISTING F O OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OWNER INSTALLED OVERFLOW DRAIN OVER HANG OPPOSITE HAND OPENING OPPOSITE OPERABLE OVER HEAD OWNER: B E EA EIFS HARDBOARD HARDWARE HARDWOOD HOLLOW METAL HORIZONTAL HAND SINK HEIGHT HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER RETURN HOT WATER SUPPLY 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 ABV A/C AC ACP AD ADDL ADF ADJ AFF AFS AGGR ALUM ALT ANOD APPROX ARCH ANCHOR BOLT ACRYLONITRILE BUTADIENE STYRENE ABOVE AIR CONDITIONING ASPHALTIC CONCRETE ACOUSTICAL CEILING PANEL AREA DRAIN ADDITIONAL ACCESSIBLE DRINKING FOUNTAIN ADJACENT ABOVE FINISH FLOOR ABOVE FINISH SLAB AGGREGATE ALUMINUM ALTERNATE ANODIZED APPROXIMATE ARCHITECTURAL HDBD HDW HDWD HM HORIZ HS HT HVAC ADDRESS: AB ABS E TCCM TOWER RELOCATION A PROJECT TITLE: ABBREVIATIONS LEGEND SIM XXXX DET_NO FURNITURE DESIGNATION WALL SECTION DESIGNATION SHT_NO 1 X REVISION DESIGNATION 1 A101 1 INTERIOR ELEVATION DESIGNATION 1 X MATCHLINE PLAN KEYNOTE NO DESCRIPTION DATE REVISIONS X DEMOLITION KEYNOTE NAME ELEVATION DATUM DESIGNATION BREAK LINE DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MJ 2015 RIM ARCHITECTS LLC DWG NO: 1 A101 VIEW NAME 1 TITLE DESIGNATION A001 SHEET GENERAL NOTES 1. 2. WHERE WALLS TO REMAIN ARE DAMAGED BY DEMOLITION, REPLACE WITH (N) MATERIALS TO MATCH EXISTING. REFER TO STRUCTURAL FOR ADDITIONAL INFORMATION. RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 23 22C 22A 22 21 19B 20 19A 19 18D 18A 18 17A 17 LEGEND (E) ITEM TO REMAIN (E) ITEM TO BE DEMOLISHED NO WORK THIS AREA ROOF DRAIN PROPOSED PLYWOOD HOARDING BEFORE COMPLETION OF SITEWORK F1 PROPOSED PLYWOOD HOARDING RELOCATION AFTER COMPLETION OF SITEWORK PERMIT SET DEMOLISH AND REMOVE (E) EXTERIOR DOOR AND DOOR FRAME 2 DEMOLISH AND REMOVE (E) EXTERIOR WALL FACADE, STOREFRONTS, CANOPIES, AND ASSOCIATED LIGHTING 3 DEMOLISH AND REMOVE (E) FOUNTAIN, RAILING, AND RAISED SEATING. INCLUDING ANY RELATED FOUNTAIN PUMP, PIPING , WIRING, AND ELECTRICAL BOXES. IMMEDIATELY BACKFILL TO AVOID WATER ACCUMULATION. 4 (E) ELEPHANT STATUE TO BE REMOVED, REFURBISHED AND RELOCATED UNDER SEPARATE PERMIT 5 DEMOLISH AND REMOVE (E) TOWER COLUMNS 6 DEMOLISH AND REMOVE PORTION OF (E) CONCRETE SLAB. REFER TO STRUCTURAL FOR EXTENT 8 7 DEMOLISH AND REPLACE (E) INTERIOR WALL AS NECESSARY 10 8 REMOVE AND RE-STOCK (E) FIELD PAVERS FOR REUSE 9 DEMOLISH (E) CEILING AS NECESSARY TO ACCESS STRUCTURE. PROTECT IN PLACE (E) FIRE SPRINKLER SUPPRESSION SYSTEM 10 DRAINS TO REMAIN, CONTRACTOR TO LOCATE LINES TO AVOID DAMAGE DURING DEMOLITION OF FOUNTAIN 11 DEMOLISH (E) COLUMNS 10 "± 7'-0 8 6 9 W3 11 2 1 1 2 W2 2 1 2 W1 11 11 9 2 2 G5 10 4 8 3 H1 U DEMOLITION FLOOR PLAN 2 1 9 SHEET TITLE: 9 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION KEYNOTES 7 9 OWNER: 1 G3 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 W4 ADDRESS: G PROJECT TITLE: F4 TCCM TOWER RELOCATION REFER TO KEYNOTES FOR AREA DEMOLISHED 7'-0" ± 5 NO DESCRIPTION PLAN NORTH 2 AD101 DEMOLITION FLOOR PLAN 1/8" = 1'-0" 0" 4' 8' 16' DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 EMF MJ 2015 RIM ARCHITECTS LLC DWG NO: AD101 SHEET GENERAL NOTES 1. 2. WHERE WALLS TO REMAIN ARE DAMAGED BY DEMOLITION, REPLACE WITH (N) MATERIALS TO MATCH EXISTING. REFER TO STRUCTURAL FOR ADDITIONAL INFORMATION. RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 23 22C 22A 22 21 19B 20 19A 19 18D 18A 18 17 17A LEGEND (E) ITEM TO REMAIN (E) ITEM TO BE DEMOLISHED NO WORK THIS AREA ROOF DRAIN PROPOSED PLYWOOD HOARDING BEFORE COMPLETION OF SITEWORK F1 PROPOSED PLYWOOD HOARDING RELOCATION AFTER COMPLETION OF SITEWORK PERMIT SET DEMOLISH AND REMOVE (E) STORAGE WALLS AND ROOF ASSEMBLY INCLUDING ANY ASSOCIATED DOORS, DOOR FRAMES, VENTS AND DOWNSPOUTS 2 DEMOLISH AND REMOVE (E) TOWER WALL AND ROOF ASSEMBLY INCLUDING THE SHIP LADDER, CLOCK ASSEMBLY AND ANY ASSOCIATED LIGHTING 3 REMOVE (E) SPIRE AND REINSTALL ON NEW TOWER ROOF 4 REPLACE (E) SEISMIC JOINT 5 REMOVE (E) SEISMIC JOINT CLADDING AND REPLACE (E) SEISMIC JOINT 6 DEMOLISH AND REMOVE (E) ROOFING 7 REMOVE (E) ROOF DRAIN 8 DEMOLISH AND REMOVE (E) PARAPET 9 REMOVE (E) ELECTRICAL PANEL AND REINSTALL AT (N) TOWER LOCATION. REFER TO ELECTRICAL DRAWINGS FOR LOCATION 10 REFERENCE NEW ROOF PLAN FOR EXTENT OF ROOFING DEMOLITION 11 REMOVE AND REPLACE (E) FLASHING FOR (N) ROOF CONSTRUCTION 12 (E) ROOF LADDER TO REMAIN 6 9 5 W3 1 8 8 7 W2 G5 W1 3 2 H1 U DEMOLITION ROOF PLAN 1 10 4 SHEET TITLE: KEYNOTES G3 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 11 12 OWNER: 11 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 W4 ADDRESS: G PROJECT TITLE: F4 TCCM TOWER RELOCATION REFER TO KEYNOTES FOR AREA DEMOLISHED PLAN NORTH 1 AD102 DEMOLITION ROOF PLAN 1/8" = 1'-0" NO DESCRIPTION 0" 4' 8' 16' DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 EMF MMJ 2015 RIM ARCHITECTS LLC DWG NO: AD102 SHEET GENERAL NOTES 1. 2. 3. REFER TO SHEET G002 FOR GENERAL PROJECT NOTES REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO A-601 FOR DOOR HARDWARE RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 22c 22 21 20 19a 19 18d 18c 20' - 0" 20' - 0" 18 17b 17a 17 1' - 2" 0' - 9" 29' - 5 1/2" 18a 19' - 3" 4' - 6" 11' - 7" 12' - 9" 9' - 8 1/2" 3' - 4 1/2" 14' - 11" LEGEND (E) WALLS (N) WALLS NO WORK THIS AREA F1 101 0' - 7 1/2" 20' - 5 1/2" TENANT TENANT 103 105 TENANT TENANT 107 109 PERMIT SET '12 1" 1' " -6 6" 1' - 9" 1' - 3' - 6" ± 8' - 0" 3' - 6" 8' - 0" 6" 1' - 6" 14' - 6" 2' - 6" 7' - 6" 1 3 (N) TENANT DEMISING WALL, TO MATCH (E) ASSEMBLY IN FINISH AND FIRE RATING. PROVIDE MINIMUM R-13 VALUE. SEE DETAILS 9 & 10 ON A503 FOR TOP AND BOTTOM WALL DETAILS 4 (E) DRAINS TO REMAIN. 5 BACKFILL EXISTING GRADE FROM DEMOLISHED FOUNTAIN AS REQUIRED WITH CLASS 2 AGGREGATE BASE. SOIL SHOULD BE MOISTURE CONDITIONED WITH A LIQUID LIMIT LESS THAN 40 AND COMPACTED TO 90% RELATIVE COMPACTION 6 LINE OF (N) FLOOR SLAB, SEE STRUCTURAL DRAWINGS 7 (E) SEISMIC JOINT 8 (E) STRUCTURE 9 1-HR RATED ENCLOSURE FOR COLUMN, REFER TO 8 ON A503 FOR TYPICAL COLUMN WRAP DETAIL. A301 3' - 6" 3 1 A201 3 A206 ± 8' - 0" 12' - 1" W2 G5 (N) CONCRETE MAT SLAB, FINISH TO MATCH EXISTING. SEE STRUCTURAL DRAWINGS 1 A204 3' - 9" A201 A502 1' - 2" " -6 A206 1' - 2 2' - 0" 8' - 4 1/8" 3' - 1 3/4" 8' - 4 1/4" 2 1' - 2 1/2" 8' - 6" 9' - 9" ± 1' - 10" 1' - 3" 8' - 3 5/8" 10 2 A205 1' G3.9 G4 (N) OR SALVAGED FIELD PAVERS. INSTALL OVER SAND BASE TO MATCH (E) CONDITIONS 2 2 7 W3 1 3' - 7" 5 W1 4 4 FIRST FLOOR PLAN 6 SHEET TITLE: 3 " 1' - 6 G3.5 12' - 11" KEYNOTES 1 A502 6" 11' - 13' - 2 1/2" " 2' - 5 9 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 9 1 11 OWNER: G3 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 ALIGN W4 ADDRESS: G PROJECT TITLE: 8 TCCM TOWER RELOCATION V 2' - 11" F4 TENANT 1 1 4 1 4 A206 A206 A205 1 A201 9 A204 1 7 A205 A204 PLAN NORTH 1 A101 FIRST FLOOR PLAN 1/8" = 1'-0" 0" 4' 8' 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS 16' DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 MEG MJ 2015 RIM ARCHITECTS LLC DWG NO: A101 SHEET GENERAL NOTES 1. 2. 3. 4. REFER TO SHEET G002 FOR GENERAL NOTES PLAN. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. CONTRACTOR TO VERIFY IN FIELD LOCATION OF (E) ROOF DRAINS. REFER TO LANDSCAPE DRAWINGS FOR ADDITIONAL PLANTERS INFORMATION RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 7 A204 23 22c 22C 22A 22 21 20 19a 19 18d 18c 18a 18 17b 17a 17 9 A204 0' - 6 1/2" 0' - 9" 15' - 1" 14' - 4 1/2" 20' - 0" 20' - 0" 19' - 3" 1' - 2" 11' - 7" 4' - 6" 22' - 6" 3' - 4 1/2" 14' - 11" LEGEND NO WORK THIS AREA F1 ROOF DRAIN 5 A501 2 1 2 7 1 G3.5 A203 9' - 9" 1 A202 1 KEYNOTES 1 W3 A301 1 PLANTERS, TYP. SEE LANDSCAPE AND STRUCTURAL DRAWINGS 2 EXTENT OF ROOF REPLACEMENT TO BE DEFINED BY LOCATION OF (E) ROOF HIGH POINT. CONTRACTOR TO VERIFY LOCATION OF ROOF HIGH POINT. 3 (N) SEISMIC JOINT 4 (N) ROOF DRAIN WITH OVERFLOW. CONNECT TO (E) STORM DRAIN PIPING BELOW. SEE PLUMBING DWGS 5 RAISED SEAM METAL ROOF W/ INTERNAL GUTTER @ TOP OF TOWER 6 (N) ALUMINUM & WIRE TRELLIS STRUCTURE, POWDER COAT FINISH. SSD 7 (N) ROOF CURB FOR TRANSITION OF ROOF MATERIALS TO OCCUR AT HIGH POINT OF ROOF, CONTRACTOR TO VERIFY LOCATION. 8 REPLACE (E) FLASHING AT BOTTOM OF PARAPET TO ACCOMMODATE (N) ROOFING 1 9 (E) ROOF LADDER A201 10 LINE OF (N) PARAPET G3.9 G4 6 4 12' - 11" 4 6 3 2 A201 A201 1 A105 W2 G5 1 3 A206 W1 5 NEW ROOF PLAN A202 3 SHEET TITLE: A503 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 2 9 OWNER: 3 4 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 0' - 4" W4 13' - 2 1/2" G3 ADDRESS: G TCCM TOWER RELOCATION V PROJECT TITLE: F4 0' - 3 1/2" 20' - 5 1/2" PERMIT SET PLAN NORTH 1 A102 ROOF PLAN 1/8" = 1'-0" 0" 4' 8' 16' 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 MEG MMJ 2015 RIM ARCHITECTS LLC DWG NO: A102 SHEET GENERAL NOTES 1. 2. 3. REFER TO SHEET G002 FOR GENERAL PROJECT NOTES REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO A-601 FOR DOOR HARDWARE RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 18 17b 2 2 A202 A202 18 17b LEGEND 14' - 10" 1' - 1" 14' - 10" 3' - 5" 3' - 5" 1' - 1" 8' - 0" 8' - 0" 3' - 5" (E) WALLS 2' - 7" 3' - 5" 0' - 10" 2' - 4" 3' - 4" 2' - 4" 0' - 10" 2' - 7" 9 10 NO WORK THIS AREA 0' - 10" 1' - 1" (N) WALLS PERMIT SET 0' - 6" 1 1 1 1 8' - 0" 1 KEYNOTES 1 8' - 0" 14' - 10" 8' - 0" A203 14' - 10" A203 1 1 A301 A301 1 12 4 2 NEW 3'-0" x 7'-0" x 1 3/4" HOLLOW METAL DOOR AND FRAME W/ DOOR HARDWARE SET 1. 3 STEEL COLUMN, SEE STRUCTURAL DRAWINGS 4 GFRC CORNICE MOLDING BELOW 5 EXPOSED STRUCTURAL STEEL 6 OPENING ABOVE 7 (N) PLYWOOD FLOOR OVER METAL STUDS. 8 PARAPET BELOW 9 LOCATION OF (N) TOWER DOWNSPOUT TERMINATION @ ROOF DECK LEVEL 10 CONCEALED ROOF DOWNSPOUT 11 NEW STUD WALL 12 STRUCTURAL BEAM, SSD. SEE DETAIL 5 / A503 13 FACE OF EIFS FINISH BELOW. SEE SECTIONS AND ELEVATIONS FOR ADDITIONAL INFORMATION 1 TYP G4 3' - 5" 3' - 5" 10 9 3 6 A503 2' - 7" G4 0' - 10" 5 7 1 A204 13 9 3 7 A204 A204 A204 A201 0' - 1" 0' - 3" 1' - 1" 8 8 1 A201 13 9 A103 TOWER FLOOR PLAN BELOW EQUIPM. LEVEL 1/2" = 1'-0" 1 0" 1' 2' 4' A103 A204 PLAN NORTH TOWER FLOOR PLAN AT (E) ROOF DECK 1/2" = 1'-0" 1 2 A204 PLAN NORTH 2 ALTERNATIVE TREAD DEVICE, TO EQUIPMENT LEVEL, WITH HANDRAILS AT EACH SIDE, WITH A A MIN. TREAD DEPTH OF 5 INCHES, A MINIMUM PROJECTED TREAD DEPTH OF 8 1/2", A MIN. TREAD WIDTH OF 7" AND A MAXIMUM RISER HEIGHT OF 9 1/2". CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ARCHITECT'S REVIEW. TOWER FLOOR PLANS 12 SHEET TITLE: A202 7 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION FFE: 16'-0" OWNER: A202 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 1 11 14 ADDRESS: 1 6 TCCM TOWER RELOCATION 0' - 3" 0' - 3" OPEN TO BELOW PROJECT TITLE: G3.5 0' - 10" G3.5 2' - 7" 3' - 5" 3' - 5" 2 0" 1' 2' 4' 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 EF MMJ 2015 RIM ARCHITECTS LLC DWG NO: A103 SHEET GENERAL NOTES 1. 2. 3. REFER TO SHEET G002 FOR GENERAL PROJECT NOTES REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO A-601 FOR DOOR HARDWARE RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 2 2 A202 A202 18 17b 18 13' - 10" 0' - 9 1/8" 0' - 9 7/8" 1' - 3 1/2" LEGEND 17b 14' - 10" .0'-9 1/8" 0' - 9 7/8" 8' - 1" 0' - 6" (E) WALLS 13' - 10" 1' - 3 1/2" 2' - 11" 0' - 6" 8' - 0" (N) WALLS 2' - 11" 7 NO WORK THIS AREA 7 4 1' - 3" 0' - 6" 4 PERMIT SET A501 9 5 1 1 1 A301 4' - 0" 1 8' - 0" RIDGELINE 13' - 10" RIDGELINE KEYNOTES A203 14' - 10" 13' - 10" 8' - 1 1/2" 6 A203 1 1 ALTERNATING TREAD DEVICES WITH HANDRAILS AT EACH SIDE, WITH A MIN. TREAD DEPTH OF 5 INCHES, A MINIMUM PROJECTED TREAD DEPTH OF 8 1/2", A MIN. TREAD WIDTH OF 7" AND A MAXIMUM RISER HEIGHT OF 9 1/2". CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ARCHITECT'S REVIEW. 2 STEEL COLUMN, REFER TO STRUCTURAL TYP. 3 INTERNALLY ILLUMINATED TRANSLUCENT CLOCK, TYP. OF 4 SIDES, OFCI. 4 CONCEALED ROOF DOWNSPOUT IN COLUMN 5 19" HIGH DECORATIVE METAL RAILING ATTACHED TO WALL, STRENGTH MIN. 50 POUNDS PLF, TYP. OF 4. FINISH TO MATCH RAISED SEAM METAL ROOF. SEE DETAIL 1 / A503 6 48"x48" ROOF HATCH 7 TOWER EXTERIOR FACE OF FINISH OUTLINE BELOW 8 SIDE WALL ROOF DRAIN, SEE DETAIL 8 / A502 9 42" GUARDRAILS WITH POSTS @ 20"O.C. MAX., TYP. AROUND OPENING A301 1/4" : 12" SLOPE 1 1 A202 A202 1 1/4" : 12" SLOPE EQ. PE LO S " 1/4 PE LO "S 1/4 0' - 9 3/8" 0' - 9 5/8" 1 8 4 2 G4 4 0' - 6" 1' - 3" 2' - 11" G4 7 1 A204 9 A204 5 1 7 A204 7 A201 A204 7 9 A201 4 A204 A204 PLAN NORTH 2 A104 TOWER TOP FLOOR PLAN 1/2" = 1'-0" A104 1' 2' 4' 1 PLAN NORTH 1 0" 1 TOWER FLOOR PLANS 1 SHEET TITLE: A501 EQ. 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 1 FFE: 35'-6" 2 PE LO "S 1/4 1/4 "S LO PE 1/4" : 12" SLOPE FFE: 41'-2" 4' - 0" OWNER: EQ. TYP. 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 1/4" : 12" SLOPE ADDRESS: 8 EQ. 0' - 9 3/8" 0' - 9 5/8" G3.5 TCCM TOWER RELOCATION G3.5 3 PROJECT TITLE: 2' - 11" 7 EQUIPMENT LEVEL FLOOR PLAN 1/2" = 1'-0" 0" 1' 2' 4' 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 MEG MMJ 2015 RIM ARCHITECTS LLC DWG NO: A104 SHEET GENERAL NOTES 1. 2. 3. REFER TO SHEET G002 FOR GENERAL PROJECT NOTES REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REFER TO A-601 FOR DOOR HARDWARE RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 2 18 17b A202 14' - 2" 9' - 9" EQ. LEGEND (E) WALLS EQ. (N) WALLS 2 NO WORK THIS AREA EQ. 6 3 1/2" / 12" 3 G3.5 PERMIT SET 5 1 KEYNOTES 4 9' - 9" 14' - 2" A203 1 3 1/2" / 12" 1 RAISED SEAM METAL ROOF 2 CONCEALED DOWNSPOUTS 3 CONCEALED ROOF GUTTER 4 RELOCATED SPIRE W/ SQUARE BASE FROM (E) TOWER. SEE STRUCTURAL FOR SPIRE ATTACHMENT DETAIL 5 VENT ALONG RIDGE 6 EIFS WALL BELOW A301 3 1/2" / 12" 5 5 A503 5 EQ. G4 6 ENLARGED TOWER ROOF PLAN 1 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 3 1/2" / 12" 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 A202 5 TCCM TOWER RELOCATION 1 7 1 9 A204 A201 A204 SHEET TITLE: OWNER: 2 ADDRESS: PROJECT TITLE: A204 PLAN NORTH 1 A105 ENLARGED TOWER ROOF PLAN 1/2" = 1'-0" 0" 1' 2' 4' NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 MG MJ 2015 RIM ARCHITECTS LLC DWG NO: A105 SHEET GENERAL NOTES 1 1. 2. A203 G3.5 G3.9 G4 2 A104 TYP. PLANTERS, SEE LANDSCAPE DRAWINGS PLANTERS, SEE LANDSCAPE DRAWINGS VIF EQUIPMENT LEVEL PARAPET CAP 2 A103 EIFS FINISHED WALL, E-1 PARAPET CAP REVEALS, TYP. VARIES. VIF CL EQ EQ A503 VARIES. VIF 1 BUILDING IN FOREGROUND OPENING LIMESTONE COLUMN BASE, TYP. (S-1) A201 . . . FACADES NOT PERPENDICULAR TO VIEW 2 0" 1/8" = 1'-0" 4' FIRST FLOOR (NGVD 2.17) 0' - 0" 8' 16' WEST ELEVATION A201 1/8" = 1'-0" 0" 4' 8' 16' 8 A204 17b 17a NGVD 62.17 (MAX. NGVD 63.5) (N) CLOCK TOWER BEYOND 3 10' - 10 1/2" TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) 2 A104 A205 TYP. A206 A205 A205 1 ALUMINUM TRELLIS, SSD 21 20 19a 19 18d 18c EQUIPMENT LEVEL 18a PLANTERS, SEE LANDSCAPE DRAWINGS PARAPET CAP (E) PARAPET BEYOND 2 A103 18' - 6 1/2" 22A ALIGN TOP OF PARAPET W/ EXISTING 1 A103 (E) ROOF DECK EIFS FINISHED WALL, E-1 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE VARIES. VIF OPENING OPENING OPENING OPENING OPENING OPENING OPENING REVISIONS 16' - 11 1/2" 23' - 0" VIF EXISTING FACADE REVEALS, TYP. WHERE INDICATED 56' - 0" 1 9' - 7 1/2" 4 PROJECT TITLE: TOWER TOP LEVEL 1 A104 23 22c 22C VIF 18 OPENING DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : FIRST FLOOR (NGVD 2.17) 0' - 0" (E) FACADE NOT IN SCOPE 1 A201 SOUTH ELEVATION 1/8" = 1'-0" FACADE NOT PERPENDICULAR EXTERIOR ELEVATIONS A503 SIM PERMIT SET SHEET TITLE: EAST ELEVATION OPENING 9 FIRST FLOOR (NGVD 2.17) 0' - 0" A206 OPENING 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION BUILDING IN FOREGROUND OWNER: OPENING 3 3 (E) ROOF DECK 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 LIMESTONE COLUMN BASE, S-1 1 (E) ROOF DECK 10 ADDRESS: OPENING FOR FUTURE STOREFRONT. CLAD W/ PLYWOOD OVER MTL FRAMING AND PAINT FINISH, TYP. REFER TO STRUCTURAL OPENING FOR FUTURE STOREFRONT. CLAD W/ PLYWOOD OVER MTL FRAMING AND PAINT FINISH, TYP. REFER TO STRUCTURAL TCCM TOWER RELOCATION LIGHT FIXTURE, SEE ELECTRICAL 1 A103 16' - 11 1/2" VIF EIFS FINISHED WALL, E-1 MATCH ADJACENT FACADE HEIGHT 3' - 6" REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 56' - 0" SUPPORT FOR PLANTERS, SSD 18' - 6 1/2" A206 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 9' - 7 1/2" 1 A104 ALUMINUM TRELLIS G4 G3.9 A R C H I T E C T S TOWER TOP LEVEL (N) CLOCK TOWER BEYOND 1 10' - 10 1/2" TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) G5 RIM G5 NGVD 62.17 (MAX. NGVD 63.5) ALUMINUM TRELLIS BEYOND, SSD REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES (E) FACADE NOT IN SCOPE 2015.03.31 136074 EF MMJ 2015 RIM ARCHITECTS LLC DWG NO: 0" 4' 8' 16' A201 SHEET GENERAL NOTES 7 9 A204 A301 A204 17b RELOCATED SPIRE FROM (E) TOWER, M-1, SSD FOR SPIRE ATTACHEMENT DETAIL NGVD 62.17 (MAX. NGVD 63.5) 1 METAL SOFFIT, MATCH M-1 2 A104 OPEN METAL RAILING, MATCH M-1 COLOR. SEE DETAIL 1 / A503 TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) 12" EIFS E-2 METAL SOFFIT, COLOR TO MATCH M-1 1 2 A104 OPEN REVEALS, TYP. METAL RAILING, COLOR TO MATCH M-1 EIFS FINISHED COLUMN, FINISH E-2 1 EIFS FINISHED COLUMNS, FINISH E-2 TOWER TOP LEVEL REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com TOWER TOP LEVEL REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 1 A104 TONE-ON-TONE STENCILING, TYP. AROUND CLOCK, E-3 1 TONE-ON-TONE STENCILING, TYP. AROUND CLOCK, E-3 A104 PERMIT SET GFRC CORNICE, PROFILE A. SEE DETAIL 9 / A501 GFRC CORNICE, PROFILE A SEE DETAIL 9 / A501 MAINTENANCE DOOR W/ LOUVER. PAINT DOOR TO MATCH ADJACENT WALL FINISH COLOR TYP. 9 A501 REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 1 A103 1 A103 PATH OF INTERNAL DOWNSPOUT. DAYLITE TO (E) ROOF 0' - 0 5/8" 0' - 10" TYP. EIFS FINISHED WALL, E-1 2 A103 EIFS FINISHED WALL, E-1 (E) ROOF DECK VARIES. VIF BUILDING IN FOREGROUND 10 (E) ROOF DECK A503 VARIES. VIF TOWER ELEVATIONS 2 A103 SHEET TITLE: EIFS FINISHED WALL, E-4 EIFS FINISHED WALL, E-4 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION EQUIPMENT LEVEL OWNER: EQUIPMENT LEVEL 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 SOFT, INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE, OFCI SOFT, INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE ADDRESS: REVEALS, TYP. SEE DETAIL 13 / A501 "/ 3 1/2 A R C H I T E C T S TCCM TOWER RELOCATION EIFS E-2 G3.5 NGVD 62.17 (MAX. NGVD 63.5) RAISED SEAM METAL ROOF W/ INTERNAL GUTTER, M-1 TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) 2" "/1 3 1/2 G4 RELOCATED SPIRE FROM (E) TOWER, M-1, SSD FOR SPIRE ATTACHEMENT DETAIL REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES PROJECT TITLE: 1 1. 2. 18 RAISED SEAM METAL ROOF W/ INTERNAL GUTTER, M-1 RIM 1 BUILDING IN FOREGROUND 9 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE A503 FIRST FLOOR (NGVD 2.17) 0' - 0" 2 A202 FIRST FLOOR (NGVD 2.17) 0' - 0" NORTH TOWER ELEVATION 1/4" = 1'-0" 1 0" 2' 4' 8' A202 REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : EAST TOWER ELEVATION 1/4" = 1'-0" 0" 2' 4' 8' 2015.03.31 136074 AJD MMJ 2015 RIM ARCHITECTS LLC DWG NO: A202 SHEET GENERAL NOTES 1. 2. RELOCATED SPIRE FROM (E) TOWER, M-1, SSD FOR SPIRE ATTACHEMENT DETAIL REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES RIM 1 A R C H I T E C T S A301 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com G3.5 G4 NGVD 62.17 (MAX. NGVD 63.5) RAISED SEAM METAL ROOF W/ INTERNAL GUTTER, M-1 TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) EIFS E-2 METAL SOFFIT, COLOR TO MATCH M-1 1 METAL RAILING, COLOR TO MATCH M-1 7' - 2" REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 10' - 10 1/2" 1 2 A104 1 TOWER TOP LEVEL EIFS FINISHED COLUMN, FINISH E-2 1 A104 9' - 7 1/2" 12' - 6" REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 PERMIT SET 10" TYP 1' - 0" PATH OF INTERNAL DOWNSPOUT. DAYLITE TO (E) ROOF (E) ROOF DECK VARIES. VIF TOWER ELEVATIONS 18' - 6 1/2" 1 A103 6' - 2" REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 SHEET TITLE: 9 A501 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 8' - 10" TYP. GFRC CORNICE, PROFILE A. SEE DETAIL 9 / A501 OWNER: EIFS FINISHED WALL, E-1 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 2 A103 EIFS FINISHED WALL, E-4 ADDRESS: TONE-ON-TONE STENCILING, TYP. AROUND CLOCK, E-3 PROJECT TITLE: EQUIPMENT LEVEL TCCM TOWER RELOCATION SOFT, INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE 11' - 0" BUILDING IN FOREGROUND 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE FIRST FLOOR (NGVD 2.17) 0' - 0" 1 A203 WEST TOWER ELEVATION 1/4" = 1'-0" 0" 2' 4' 8' REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MMJ 2015 RIM ARCHITECTS LLC DWG NO: A203 SHEET 9 A204 A204 RELOCATED SPIRE FROM (E) TOWER, SSD FOR SPIRE ATTACHEMENT DETAIL EIFS E-2 A204 EQUIPMENT LEVEL TOWER TOP LEVEL - KEY PLAN A204 1' - 3" 3' - 1" CLOCK BEYOND REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 1/4" = 1'-0" 1 A104 18 G4 EIFS FINISHED WALL, E-1 EQUIPMENT LEVEL EQUIPMENT LEVEL PERMIT SET 1 ALTERNATIVE TREAD DEVICE EIFS FINISHED WALL, E-4 9 A501 MAINTENANCE DOOR W/ LOUVER TYP. 9 A501 0' - 10" TYP. GFRC CORNICE, PROFILE A, SEE DETAIL 12 / A502 AREA FOR FULL-EXPRESSION TENANT FACADE VARIES. VIF 9 AREA FOR TENANT STOREFRONT (N) MAT SLAB, SSD EQ CL EQ BUILDING ENCLOSURE PREPARED FOR TENANT IMPROVEMENTS EQ. CL 1 A103 PLYWOOD DECKING OVER MTL STUDS (E) ROOF DECK (E) ROOF DECK VARIES. VIF VARIES. VIF OPENING LIMESTONE REVEAL, TYP. SEE DETAIL 4 / A502 1/4" = 1'-0" 18 910 PLAN AT ROOF DECK - KEY PLAN 2 A204 1/4" = 1'-0" 18 (N) OR SALVAGED FIELD PAVERS FIRST FLOOR (NGVD 2.17) 0' - 0" TOWER SECTION @ STOREFRONT OPENING 1/4" = 1'-0" 0" 2' 4' 8 8' A204 SOUTH TOWER ELEVATION 1/4" = 1'-0" 7 0" 2' 4' 8' A204 17a G4 FIRST FLOOR (NGVD 2.17) 0' - 0" 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE FIRST FLOOR - KEY PLAN A204 A204 17b 3 A502 1 9 17b G4 VAPOR RETARDER UNDER SLAB AND MAT FOUNDATION A503 A503 LIMESTONE COLUMN BASE (S-1) FIRST FLOOR (NGVD 2.17) 0' - 0" A204 (N) MAT SLAB, SSD CLAD OPENING W/ PLYWOOD OVER WOOD FRAMING AND PAINT FINISH, TYP. A503 PLAN BELOW MAINT. LVL - KEY PLAN 3 GFRC CORNICE EQ. 11' - 0" 4 A501 ARCHITECTURAL DECORATIVE SCONCE LIGHTING, SEE ELECTRICAL FOR MOUNTING HEIGHT 17b GRFC CORNICE 1 A103 0' - 7 1/4" (E) ROOF DECK 1/4" = 1'-0" G4 EIFS FINISHED WALL, E-1 PLYWOOD DECKING OVER MTL STUDS A204 18 GRFC CORNICE, PROFILE B. SEE DETAIL 9 / A501 REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 1 A103 56' - 0" GFRC CORNICE, BEYOND EQUIPM. LEVEL - KEY PLAN TYP. DECORATIVE UPLIGHTING, SEE ELECTRICAL DWGS 1' - 2" A501 FUTURE BRONZE SCULPTURES 4 2 A103 5' - 0" 5 2 A103 8' - 10" 1-HR SFRM ON STRUCTURAL MEMBERS TO INCLUDE, BEAMS, COLUMNS, AND BRACES, TYP 2 A103 17b 1/4" = 1'-0" 0" 2' REVISIONS 4' 0" 2' 4' 8' DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : TOWER SECTION @ NEUTRAL PIER 1/4" = 1'-0" TOWER SECTIONS AND ELEVATION SOFT, INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE TOWER TOP LEVEL 1 A104 12' - 6" 1 A104 G4 5 SOFT INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE 17b SHEET TITLE: 6' - 4" DIA RO, TYP CONTRACTOR VERIFY WITH MANUF 42" HIGH GUARDS AROUND OPENING METAL RAILING BEYOND STRUCTURAL COLUMN WITH EIFS FURRING, SSD TOWER TOP LEVEL TONE-ON-TONE STENCILING, TYP. AROUND CLOCK, E-3 18 2 A104 EIFS FINISHED COLUMN, E-2 A502 1 1' - 7" METAL RAILING 2 A104 1' - 3" 7' - 2" CEILING HEIGHT 3' - 2" 3' - 6" MIN. TYP. TOWER TOP LEVEL 1/4" = 1'-0" EXT. METAL CEILING, C-1 REVEALS, TYP. WHERE INDICATED. SEE DETAIL 13 / A501 8 TOWER ROOF PLAN - KEY PLAN 6 METAL SOFFIT 2 A104 VAPOR RETARDER UNDER SLAB AND MAT FOUNDATION A501 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION METAL RAILING TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) 12" OWNER: 1 TYP. 11 "/ 3 1/2 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) A R C H I T E C T S SEAM ROOF W/ INTERNAL GUTTER ADDRESS: A501 1 NGVD 62.17 (MAX. NGVD 63.5) RAISED SEAM METAL ROOF W/ INTERNAL GUTTER, M-1 TYP. 11 RIM G4 G4 17b PROJECT TITLE: NGVD 62.17 (MAX. NGVD 63.5) RAISED SEAM METAL ROOF W/ INTERNAL GUTTER 18 17b TCCM TOWER RELOCATION G3.9 G4 18 VIF G3.5 7 A301 0' - 10" RELOCATED SPIRE FROM (E) TOWER, M-1, SSD FOR SPIRE ATTACHMENT DETAIL 1 8' GENERAL NOTES 1. 2. REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES 2015.03.31 136074 AJD/MEG MMJ 2015 RIM ARCHITECTS LLC DWG NO: A204 SHEET ALUMINUM & WIRE TRELLIS STRUCTURE 4 G4 G3.9 18c SSD 1 18a A205 SSD G4 G3.9 ALUMINUM & WIRE TRELLIS STRUCTURE ALUMINUM & WIRE TRELLIS STRUCTURE A205 SSD RIM SSD A R C H I T E C T S 1 1 TRELLIS STRUCTURE, SSD TRELLIS STRUCTURE, SSD TRELLIS STRUCTURE, SSD CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com CYLINDER PLANTER CYLINDER PLANTER RECTILINEAR PLANTER RECTILINEAR PLANTER PARAPET CAP 1' - 4 1/2" FOS PLANTER STRUCTURE, SSD A502 SIM PLANTER STRUCTURE, SSD 0' - 10" TYP. 4' - 9" FACE OF NEUTRAL PIER BEYOND PARAPET TYPE 1 7 PARAPET TYPE 1 A502 ROOF TYPE 1 ELEVATION VARIES 0' - 1" (E) ROOF DECK (E) ROOF DECK VARIES. VIF A502 1' - 9" EQ EQ WALL TYPE 2 11' - 0" 1' - 9" 2" MTL STUD FURRING ARCHITECTURAL DECORATIVE SCONCE LIGHTING, SEE ELECTRICAL FOR MOUNTING HEIGHT OPENING (E) FLOOR SLAB LIMESTONE COLUMN BASE, S-1 SEAL WEATHER BARRIER TO TOP OF SLAB LIMESTONE REVEAL, TYP. SEE DETAIL 4 / A502 1' - 9" (N) OR SALVAGED FIELD PAVERS FIRST FLOOR (NGVD 2.17) 0' - 0" 3 SLAB EXTENSION, SSD WALL SECTION @ STOREFRONT OPENING 1/2" = 1'-0" 0" 1' 2' FIRST FLOOR (NGVD 2.17) 0' - 0" FIRST FLOOR (NGVD 2.17) 0' - 0" SPACER ENLARGED BAY ELEVATION A205 1/2" = 1'-0" 18d 18c 0" 1' 2' 18a 2' - 8" 8' - 3 1/2" SLAB EXTENSION SSD 4' 1 3' - 2 1/2" A205 4' WALL SECTION @ NEUTRAL PIER 1/2" = 1'-0" 0" G3.9 G4 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE 1' 2' 4' 9 A502 GENERAL NOTES 2 A205 ENLARGED BAY PLAN 1/2" = 1'-0" 0" 1' 2' 4' REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2' - 1 1/2" A205 0' - 4 1/4" WALL SECTIONS AND ENLARGED BAY ELEVATION/PLAN 15 SHEET TITLE: (E) CEILING TO BE DEMOLISHED AND REPAIRED AS NEEDED 1' - 4 1/2" (N) OR SALVAGED FIELD PAVERS 4 TCCM TOWER RELOCATION 0' - 9" 1' - 6" CL PROJECT TITLE: (E) FLOOR SLAB A502 GFRC CORNICE, PROFILE A 1' - 9" EDGE OF NEUTRAL PIER BEYOND 0' - 5" 0' - 6" 12 1' - 9" (E) CEILING TO BE DEMOLISHED AND REPAIRED AS NEEDED BUILDING ENCLOSURE PREPARED FOR TENANT IMPROVEMENTS AREA OF FULL EXPRESSION TENANT FACADE MATCH ADJACENT FACADE BUILDING ENCLOSURE, PREPARED FOR TENANT IMPROVEMENTS: -WEATHER BARRIER -PLYWD -METAL STUDS WITH BATT INSULATION -VAPOR RETARDER -5/8" GWB 10' - 0" AREA OF TENANT STOREFRONT AREA OF FULL-EXPRESSION TENANT FACADE WALL TYPE 1 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION PERMIT SET EIFS FINISHED WALL, E-1 OWNER: VARIES. VIF 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 0' - 2 1/2" 0' - 10" ADDRESS: ROOF TYPE 1 (E) DECK ELEVATION VARIES 1' - 4 1/2" 13 MATCH ADJACENT COPING HEIGHT PARAPET CAP 1. 2. REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES 2015.03.31 136074 EF MMJ 2015 RIM ARCHITECTS LLC DWG NO: A205 SHEET G5 ALUMINUM & WIRE TRELLIS STRUCTURE SSD TYP. TYP. FACADE NOT PERPENDICULAR TO VIEW 4 1 A206 A206 FACADE NOT PERPENDICULAR TO VIEW G5 ALUMINUM & WIRE TRELLIS STRUCTURE SSD 1 SSD RIM SSD 1 A R C H I T E C T S ALUMINUM & WIRE TRELLIS STRUCTURE TRELLIS STRUCTURE, SSD CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com TRELLIS STRUCTURE, SSD TRELLIS STRUCTURE, SSD CYLINDER PLANTER CYLINDER PLANTER RECTILINEAR PLANTER PARAPET CAP PARAPET CAP PARAPET CAP 13 13 A502 A502 SIM RECTILINIER PLANTER 4' - 9" PLANTER STRUCTURE, REFER TO STRUCTURAL REVEALS, TYP., WHERE INDICATED PLANTER STRUCTURE, SSD PARAPET TYPE 1 PARAPET TYPE 1 16 ROOF TYPE 1 ELEVATION VARIES ROOF TYPE 1 ELEVATION VARIES (E) ROOF DECK (E) ROOF DECK (E) ROOF DECK VARIES. VIF VARIES. VIF A502 VARIES. VIF PERMIT SET TENANT CANOPY N.I.C. OPENING FOR FUTURE STOREFRONT. CLAD W/ PLYWOOD OVER WOOD FRAMING AND PAINT FINISH, TYP. OPENING TYP. 6 6 A502 A502 1' - 9" A502 A206 A206 WALL SECTION @ NEUTRAL PIER 1/2" = 1'-0" 0" 1' 2' A502 (N) OR SALVAGED FIELD PAVERS FIRST FLOOR (NGVD 2.17) 0' - 0" FIRST FLOOR (NGVD 2.17) 0' - 0" ENLARGED BAY ELEVATION, TYP 3 SLAB EXTENSION VARIES 1 LIMESTONE COLUMN BASE, S-1 5 FIRST FLOOR (NGVD 2.17) 0' - 0" 4 (E) FLOOR SLAB 1' - 9" (E) FLOOR SLAB (N) OR SALVAGED FIELD PAVERS A502 NEUTRAL PIER BEYOND REVEAL, TYP. AT TILE JOINT. SEE DETAIL 4 / A502 WALL TYPE 2 (E) CEILING TO BE DEMOLISHED AND REPAIRED AS NEEDED WALL SECTIONS AND ENLARGED BAY ELEVATION/PLAN WALL TYPE 1 2 SHEET TITLE: ARCHITECTURAL DECORATIVE SCONCE LIGHTING, SEE ELECTRICAL FOR MOUNTING HEIGHT 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION EQ. OWNER: CL 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 EQ. ADDRESS: EQ. TCCM TOWER RELOCATION CL PROJECT TITLE: EQ. BUILDING ENCLOSURE, PREPARED FOR TENANT IMPROVEMENTS: -WEATHER BARRIER -PLYWD -METAL STUDS WITH BATT INSULATION -VAPOR RETARDER -5/8" GWB AREA OF TENANT STOREFRONT (E) CEILING TO BE DEMOLISHED AND REPAIRED AS NEEDED BUILDING ENCLOSURE PREPARED FOR TENANT IMPROVEMENTS AREA OF FULL-EXPRESSION TENANT FACADE EIFS FINISHED WALL, E-1 MATCH ADJACENT FACADE HEIGHT WALL TYPE 1 WITH 5" FURRING 1/2" = 1'-0" 0" 1' 2' 4' V SLAB EXTENSION SSD 1 A206 4' 1' - 6 " 1' - 6" W2 2 A206 12' - 1" 1/2" = 1'-0" 0" 1' 2' " 1' - 6 1' - 6" 4' REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : GENERAL NOTES W1 ENLARGED BAY PLAN, TYP 1/2" = 1'-0" WALL SECTION @ STOREFRONT OPENING 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE 0" 1' 2' 4' 1. 2. REFER TO SHEET A-601 FOR EXTERIOR FINISH SCHEDULE REFER TO SHEET A-601 FOR ASSEMBLY TYPES 2015.03.31 136074 EF MMJ 2015 RIM ARCHITECTS LLC DWG NO: A206 SHEET 7 A204 RIM 9 A204 A R C H I T E C T S 21 20 19a 19 18d 18c 18a 18 17b 17a 0 RELOCATED SPIRE FROM (E) TOWER, SSD FOR SPIRE ATTACHMENT DETAIL NGVD 62.17 (MAX. NGVD 63.5) CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com TOP OF TOWER (NGVD 58.17) (MAX. NGVD 59.5) RAISED SEAM METAL ROOF W/ INTERNAL GUTTER 11 A501 2 A104 METAL RAILING 12 A501 10 A501 1 TOWER TOP LEVEL 6' - 4" RO DIA, TYP CONTRACTOR TO VERIFY 1-HR SFRM ON STRUCTURAL MEMBERS TO INCLUDE, BEAMS, COLUMNS, AND BRACES, TYP 1 A104 SOFT, INTERNALLY ILLUMINATED TRANSLUCENT CLOCK FACE 1 PERMIT SET 9 A501 8' - 5 1/2" 1 A103 NEW ROOFING 6 A501 PLYWOOD DECKING OVER MTL STUDS 8 7 A501 A501 (E) ROOF DECK PROJECT TITLE: VARIES. VIF BUILDING SECTION A GFRC CORNICE SHEET TITLE: 56' - 0" NEW WALL W/ SLOPED TOP 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION ALTERNATING TREAD DEVICE OWNER: 2 A103 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 NOT PERPENDICULAR TO VIEW ADDRESS: ALTERNATING TREAD DEVICE BEYOND TCCM TOWER RELOCATION EQUIPMENT LEVEL TENANT SPACE 109 TENANT SPACE 103 TENANT SPACE 105 TENANT SPACE 107 (N) DEMISING WALL (N) SLAB MAT, SSD VAPOR RETARDER UNDER SLAB AND MAT FOUNDATION FIRST FLOOR (NGVD 2.17) 0' - 0" 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS 1 A301 DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : SECTION A 1/4" = 1'-0" 0" 2' 4' 8' 2015.03.31 136074 MEG MJ 2015 RIM ARCHITECTS LLC DWG NO: A301 SHEET WRAP EPDM UP AND OVER DOOR, SILL. ROOF ASSEMBLY 2 30# ROOFING FELT 'Z' RETAINING STRIP 1 LAP WEATHER BARRIER OVER FRYREGLET WRAP VAPOR RETARDER OVER SILL BACKER ROD AND SEALANT 2x BLOCKING PREFINISHED FRYREGLET AND FLASHING TOWER FLOOR ASSEMBLY - 3/4" PLYWOOD OVER - MTL STUDS AS SCHEDULED 1 1 1/2" = 1'-0" EXT CEILING DETAIL A501 A501 3" = 1'-0" 1 1/2" = 1'-0" 3 5/8" MTL STUD A501 11 0' - 6" A501 (E) PARAPET WALL PROVIDE VENTING PANEL AT PERIMETER METAL CEILING, C-1 14 TOWER DOOR THRESHOLD 4 (E) FLASHING, REMOVE AND REPLACE FOR (N) ROOF CONSTRUCTION, FLASHING CAP W/ SEALANT EA SIDE TYP. TOWER ROOF EDGE DETAIL 1 1/2" = 1'-0" RUN NEW ROOFING OVER CURB WRAP NEW ROOF MEMBRANE UP (E) WALL MIN. 8", INSTALL (N) FLASHING OVER MEMBRANE. FLASHING AND SEALANT CONTINUOUS SEALANT 4" MIN ROOF ASSEMBLY TYPE 1 WRAP (E) BUR OVER CURB METAL RAILING, ATTACH TO WALL AT ENDS ROOF ASSEMBLY TYPE 1 7 A501 FLASHING TAPE EIFS WALL ASSEMBLY - EIFS - RIGID INSULATION TYPE 1 - FLUID APPLIED WEATHER BARRIER - 1/2" DENS BACKER BOARD - MTLS STUDS @ 16" OC, FILL W/ BATT INSUL EIFS EPS BOARD 0' - 0 1/2" 0' - 0 1/2" 3/4" MIN. ROOF TRANSITION A501 1 1/2" = 1'-0" 18d A501 10 A501 6" = 1'-0" VAPOR RETARDER PREFINISHED MTL FLASHING CAP W/ #14 SCREW W/ NEOPRENE WASHER AT 12" OC 5/8" GYPSUM BOARD SEISMIC JOINT 0' - 4" MIN BUILD UP AS REQ'D CL ROOF TYPE 1 1 1/2" = 1'-0" 6" DBL MTL STUD, AS SCHEDULED FLASHING TAPE 1 WRAP EPDM ON TOP OF PARAPET WALL EIFS COLUMN ASSEMBLY - 3/4" RIGID INSULATION - FLUID APPLIED WEATHER BARRIER - 1/2" EXT GRADE SHEATHING - 1 5/8" MTL STUD METAL RAILING SYSTEM TOWER PARAPET / BALUSTRADE VARIES SEE WALL SECTIONS ROOF DRAIN LEADER 1' - 7" 18c EIFS REVEAL, TYP. WHERE INDICATED TYP. REVEAL DETAIL 1 1/2" = 1'-0" CL TOWER TOP LEVEL 13 (N) ROOF AT (E) PARAPET 3 1' - 7" 3'-6" MIN RUN EPDM MEMBRANE UP AND OVER WALL SEALANT AND BACKER ROD FLASHING AND SEALANT PERMIT SET NEW ROOF CURB W/ 2x STUDS AND BATT INSULATION, 1/2" PLYWD EA SIDE. 6 A501 FLASHING @ ROOF SEISMIC JOINT 2 A501 1 1/2" = 1'-0" COLUMN FURRING, TYP DETAILS 14 A501 TOWER WALL DETAIL AT ROOF SHEET TITLE: LINEAR CEILING PANEL, C-1 8 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION CARRIER 1 OWNER: EIFS SYSTEM. SEE 11/A501 ROOF ASSEMBLY TYPE 1 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 FLASHING SHEATHING ADDRESS: FLASHING, SEALANT AND BACKER ROD EIFS SYSTEM (FINISH E-2) - 3/4" RIGID INSULATION, VAPOR RETARDER - 1/2" PLYWD - 1 5/8" MTL STUD ROOF ASSEMBLY TYPE 1 TCCM TOWER RELOCATION 0' - 4" MAX CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 6" MTL STUDS W/ BATT INSULATION CONCEALED GUTTER SLOPED TO DRAIN J TRIM 0' - 0 1/4" 2x BLOCKING 0' - 5" WALL ANGLE EXTEND ROOFING MEMBRANE UP WALL A R C H I T E C T S PROJECT TITLE: 0' - 4" MAX 0' - 6" CEILING SUSPENSION SYSTEM, PER MANUFACTURE. ATTACH TO STRUCTURE ABOVE 0' - 5" 0' - 4" 24 GA MTL FLASHING RIM 1 1/2" = 1'-0" 0' - 9" DRAINAGE STRIP 0' - 4 5/8" WALL TYPE 1 5/8" GYPSUM BOARD WALL TYPE 1 6" MTL STUDS W/ BATT INSULATION DRAINAGE STRIP PER MANUFACTURER 2x BLOCKING METAL FLASHING, BACKER ROD AND SEALANT ROLLED ALUM ANGLE RING FASTENED TO ALUM EXTENSION WALL TYPE 1 14 GA GALV STEEL CURB FRAME 0' - 2" 1' - 6" 5/8" GWB 0' - 2" 3 5/8" MTL STUD W/ BATT INSUL WRAP NEW MEMBRANE UP ROOF HATCH SIDE WALL, INSTALL FLASHING MEMBRANE OVER ROOF MEMBRANE SEALANT AND CLOSED CELL BACKER ROD W/ WEEP TUBES EVERY 24" FLASHING GFRC CORNICE HOLLOW METAL FRAME BEYOND 0' - 8" FLASHING TAPE 1 3/16" TYP ROOF HATCH 0' - 2" ALUM EXTENSION BOLTED TO BLOCK AND SPACERS AS REQD SEALANT AND BACKER ROD ACRYLIC DIAL CLOCK INSULATED HOLLOW METAL DOOR WALL TYPE 1 ROOF ASSEMBLY TYPE 1 REVISIONS ROLLED RETAINING RING BACKER ROD AND SEALANT 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 Author Checker 2015 RIM ARCHITECTS LLC PEEL AND STICK EPDM FLASHING 0' - 9" DWG NO: 12 A501 ROOF HATCH CURB DETAIL 1 1/2" = 1'-0" 9 A501 TOWER CORNICE DETAIL 1 1/2" = 1'-0" 5 A501 TOWER DOOR HEAD/JAMB SIM. 3" = 1'-0" 1 A501 CLOCK MOUNT AT HEAD/JAMB SIM 1 1/2" = 1'-0" A501 SHEET SIDE WALL ROOF DRAIN AT LOCATION INDICATED ON ROOF PLAN, SEE PLUMBING DRAWINGS GFRC CORNICE A502 ROOF TYPE 2 WALL CORNICE DETAIL 17b 1 1/2" = 1'-0" 8 A502 (E) WALL 3" = 1'-0" CONTROL JOINT SEALANT & BACKER ROD WRAP EPDM UP OVER PARAPET WALL WALL TYPE 1 ALUM TUBE TRELLIS SUPPORT, SEE STRUCTURAL W4 (E) COLUMN, SSD CONTROL JOINT STRUCTURAL COLUMNS, SSD PERMIT SET 15 A502 STOREFRONT WALL TRANSITION 1 1/2" = 1'-0" UNCURED EPDM FLASHING A502 1" = 1'-0" 0' - 5 1/2" 18d 18c 0' - 3" (N) COLUMN, SSD HORIZONTAL FURRING ALUM. EDGE SCHLUTER "INDEC" , TYP. ALL CORNERS (N) WALL AT (E) BUILDING JOINT 1 11 SEALANT 7 0' - 1 1/4" FO FURRING A502 PLANTER SUPPORT PENETRATION (N) WALL AT (E) BUILDING JOINT 2 3 A502 1 1/2" = 1'-0" 1" = 1'-0" 0' - 6 11/16" 0' - 5 1/2" WALL TYPE 2 0' - 2 1/8" WALL TYPE 1 ALUM. EDGE SCHLUTER 'JOLLY', TYP. ALL ENDS G4 WALL ASSEMBLY - WEATHER BARRIER - 1/2" DENS BACKER BOARD - MTL STUDS AT 16" OC W/ BATT INSUL - 6 MIL VAPOR RETARDER - 5/8" GYP. STRUCTURAL COLUMNS, SSD WALL TYPE 1 RETURN LIMESTONE TILE TO SHEATHING ALUM. EDGE SCHLUTER 'INDEC', TYP. ALL CORNERS A502 EIFS TO STONE TILE VERTICAL JOINT A502 1 1/2" = 1'-0" A502 PREFINISHED PARAPET CAP, TYP. WRAP WEATHER BARRIER OVER TOP OF PARAPET 2 1/2" (E) STRUCTURAL COLUMNS, SEE STRUCT. (N) OR SALVAGED FIELD PAVERS 1 1/2" = 1'-0" 0' - 2" 0' - 4" 9 A502 NEW STRUCTURAL COLUMNS, SEE STRUCT. 1/2" ASPHALT SATURATED EXPANSION MATERIAL AT CONC. EDGE. (N) OR SALVAGED FIELD PAVERS 1' - 6" MAX 1/2" ASPHALT SATURATED EXPANSION MATERIAL AT CONC. EDGE. WRAP VAPOR RETARDER OVER WEATHER BARRIER (E) CONCRETE SLAB OVER VAPOR RETARDER (E) CONCRETE SLAB OVER VAPOR RETARDER LIMESTONE OVER EXT. SHEATHING EIFS EDGE TRIM (N) CONCRETE SLAB TIED INTO EXISTING, SEE STRUCTURAL (N) CONCRETE SLAB TIED INTO EXISTING, SEE STRUCTURAL PROPOSED TENANT STOREFRONT, NIC. EXTERIOR SEISMIC JOINT - EIFS TO STONE TILE 1" = 1'-0" WALL BEYOND FLASHING 0' - 4" LAP EPDM ROOF MEMBRANE OVER TOP OF PARAPET. 1 1/2" = 1'-0" TENANT FACADE OPENING - HEAD WALL TYPE 2 SEISMIC JOINT PARAPET TYPE 1, SEE A601 A502 2 A502 1 1/2" = 1'-0" PROPOSED TENANT STOREFRONT, NIC. FLASHING TAPE TYP. PARAPET CAP DETAIL EIFS TO STONE TILE HORIZONTAL JOINT WRAP VAPOR RETARDER OVER (E) WALLS. G4 13 5/8" EXT GRADE SHTHG OVER 2 1/2" MTL STUDS AND BATT INSUL (E) INTERIOR WALLS 18c 0' - 8" 1/4":1'-0" 0' - 2 1/8" FUTURE TENANT STOREFRONT OPENING 6 1" = 1'-0" 18d VARIES STRUCTURAL STEEL TUBE, SEE STRUCTURAL GYP RETURN 10' - 0 1/2" AFF ALUM. EDGE SCHLUTER 'INDEC', TYP. ALL CORNERS OUTSIDE CORNER 10 NEW TENANT CEILING, NIC. DARK COLOR METAL FLASHING, MATCH LIMESTONE TONES 1" FURRING WALL TYPE 2 LIMESTONE OVER DENS BACKER BOARD 0' - 2 5/8" SEALANT & BACKER ROD 14 ANGLE, SSD SEALANT AND CLOSED CELL BACKER ROD W/ WEEP TUBES EVERY 24" 1' - 2" G5 0' - 8 1/2" HORIZONTAL MTL FURRING DETAILS ALUM EDGE SCHLUTER "INDEC" , TYP. ALL CORNERS LIMESTONE OVER WEATHER BARRIER OVER EXTERIOR SHEATHING 0' - 5" WALL ABOVE 0' - 1 1/4" FO FURRING FUTURE TENANT STOREFRONT OPENING SHEET TITLE: EXTERIOR FACE OF STOREFRONT RETURN EIFS TO (N) STONE PIER 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION F4 G4 PARAPET CAP FLASHING OWNER: V 17a SIDEWALL ROOF DRAIN 0' - 6" 0' - 10" " 0 1/2 1' - 1 FULL EXPRESSION TENANT STOREFRONT ALLOWANCE 0' - 4" 0' - 2" COORDINATE EXTENT OF EXTERIOR SHEATHING W/ FUTURE TENANT STOREFRONT 6" = 1'-0" 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 A502 TYP. LIMESTOME REVEAL ADDRESS: 12 1 1/2" = 1'-0" LIMESTONE CLADDING, SEE FINISH SCHEDULE 2' - 4" SOFFIT CORNER 1 4 0' - 4 5/8" 0' - 1 3/4" 0' - 0 3/4" CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com TCCM TOWER RELOCATION FLASHING A R C H I T E C T S ALUM. SCHLUTER 'DECO-SG' REVEAL TRIM TOWER TOP LEVEL FLASHING, BACKER ROD, AND CONTINUOUS SEALANT WALL TYPE 2 RIM PROJECT TITLE: 0' - 1 1/2" 0' - 3" 0' - 4 1/2" SEALANT AND CLOSED CELL BACKER ROD W/ WEEP TUBES EVERY 24" LIMESTONE TILE, SEE FINISH SCHEDULE 0' - 0 1/2" INSTALL EPDM MEMBRANE UP PARAPET WALL FLASHING TAPE 4" TYP A502 WALL TYPE 1 DRAINAGE STRIP 2"-4" VARIES SEE WALL SECTIONS 16 FLASHING TAPE WALL TYPE 1 DRAINAGE STRIP 3/4" FLASHING AND FLASHING TAPE 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 Author MMJ 2015 RIM ARCHITECTS LLC DWG NO: 5 A502 EXTERIOR WALL TO GROUND TRANS 1 1/2" = 1'-0" 1 A502 FUTURE TENANT OPENING TRANSITION 1 1/2" = 1'-0" A502 SHEET 1 RIM EXTERIOR WALL TYPE 1 BACKER ROD AND SEALANT AT PARAPET CAP AND EIFS JOINT A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com PARAPET CAP PARAPET CAP BLOCKING 7 1 A503 PARAPET FLASHING TO EIFS WALL INTERSECTION 1 1/2" = 1'-0" 17a ROOF TYPE 1 EXTERIOR WALL TYPE 1 SEALANT AND BACKER ROD G4 CONTINOUS SEALANT @ BOTH SIDES DEFLECTION TRACK PARAPET TYPE 1 5/8" GWB 6" MTL STUD WITH BATT INSULATION (R-13 MIN) 5/8" GWB NEW PARAPET CAP ABOVE SEAL EDGE OVER EXISTING PARAPET EXISTING PARAPET STEEL TRELLIS SUPPORT, SEE STRUCTURAL 1 VERTICAL PENETRATION SEAL VAPOR RETARDER TO PIPE PENETRATION 5/8" GWB 6" MTL STUD WITH BATT INSULATION (R-13 MIN) 5/8" GWB CONTINOUS SEALANT @ BOTH SIDES (E) ROOF DECK FLEXIBLE FLASHING AROUND STEEL TUBE NEW FLOOR SLAB VARIES. VIF SEALANT AND BACKER ROD WALL BASE DETAIL 9 A503 5 A503 1 1/2" = 1'-0" STEEL PENETRATION @ EXTERIOR WALL 2 A503 1 1/2" = 1'-0" TYP ROOF PENENTRATION 1 1/2" = 1'-0" TOP AND BOTTOM 2"x2" SQUARE HANDRAILS SEALANT AT NEW FLASHING EDGE TO EXISTING PARAPET CAP G 0' - 4" 1 5/8" MTL STUD W4 0' - 4" " 0' - 4 " 0' - 4 3'-6" MIN. FLASHING FLEXIBLE FLASHING @ NEW TO EXSITING PARAPET JOINT, TURN DOWN EDGES 1' - 4" 0' - 5 5/8" 0' - 7" TYP. 1"X1" SQUARE VERTICAL RAILS 0' - 1 1/2" EXISTING PARAPET CAP (2) LAYERS 1/2" TYPE 'X' GWB 1' - 7" 0' - 5 5/8" 0' - 1 1/2" V 1 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE REVISIONS 7 A502 TRELLIS SUPPORT, SEE STRUCTURAL PARAPET CAP 8 A503 DETAILS EPDM PIPE BOOT SHEET TITLE: EXTERIOR WALL TYPE 1 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION 1 1/2" = 1'-0" OWNER: 1 1/2" = 1'-0" PARAPET TO EIFS WALL INTERSECTION ADDRESS: A503 TCCM TOWER RELOCATION A503 6 PROJECT TITLE: TOP OF WALL DETAIL 10 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 PERMIT SET WHERE STRUCTURE PENETRATES WALL PROVIDE CONTINUOUS SEALANT TYP 1 HR COLUMN WRAP 3" = 1'-0" 1-HR UL X528 4 A503 NEW TO EXISTING PARAPET 1 1/2" = 1'-0" INTERIOR FLOOR LEVEL 1 A503 DECORATIVE HANDRAIL DETAIL 1" = 1'-0" DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MMJ 2015 RIM ARCHITECTS LLC DWG NO: A503 SHEET 20 W1 19a 19 18d 18c 18a 18 17b EXTERIOR ASSEMBLY TYPES 17a RIM WALL TYPE 1 (MIN U-FACTOR 0.082): EIFS FINISH 1 EPS INSULATION - TYPE I FLUID APPLIED WEATHER BARRIER 1/2" DENSGLASS SHEATHING MTL STUDS @ 16" OC, FILL WITH BATT INSULATION 6 MIL VAPOR RETARDER 5/8" GYPSUM BOARD G3.9 G4 A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com WALL TYPE 2 (MIN U-FACTOR 0.082): STONE PANEL 1 1/2" BACKERBOARD WEATHER BARRIER 1/2" DENSGLASS SHEATHING FURRING, REFER TO DETAILS 1/2" SHEATHGING MTL STUDS @ 16" OC, FILL WITH BATT INSULATION 6 MIL VAPOR RETARDER 5/8" GYPSUM BOARD V PARAPET TYPE 1: EIFS FINISH EPS INSULATION - TYPE I FLUID APPLIED WEATHER BARRIER 1/2" EXTERIOR GRADE SHEATHING MTL STUDS @ 16" OC, FILL WITH BATT INSULATION 1/2" EXTERIOR GRADE SHEATHING SINGLE PLY EPDM EXISTING DRAIN, TO REMAIN. DRAINS SHALL COMPLY WITH CBC 11B-302.3 GRADING DIAGRAM A601 3 EA 1 EA 1 EA 1 SET 1 EA HINGES STOREROOM LOCKSET SURFACE CLOSER GASKET DOOR SHOE 5BB1 4.5 x 4.5 ND96PD RHO 4040XP H SRI 2525B 319EV IVE SCH LCN NGP NGP PROJECT TITLE: DOOR HARDWARE SET 1 630 626 689 BRN AL EXTERIOR FINISH AND HARDWARE SCHEDULE 1 DIRECTION OF DRAINAGE. SLOPE SHALL NOT EXCEED 2% IN ANY DIRECTION SHEET TITLE: ROOF TYPE 2: FRAMING, SEE STRUCTURAL 1/2" PLYWOOD SHEATHING 30# ROOFING FELT STANDING SEAM METAL ROOF (SRI VALUE: 16 MIN) EXTENT OF NEW PAVING 1 TCCM TOWER RELOCATION 1 770 TAMALPAIS DR. INC., A FLORIDA CORPORATION H1 PERMIT SET OWNER: 1 1 ROOF TYPE 1: TYPICAL UNO ROOF TRUSSES- EXISTING PLYWOOD SHEATHING - EXISTING 1/2" DENS DECK 10 MIL VAPOR RETARDER TAPERED RIGID INSULATION 1/2" COVER BOARD- MECHANICALLY FASTENED SINGLE PLY EPDM (SRI VALUE: 75 MIN) 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 0 ADDRESS: G5 EXTERIOR FINISH LEGEND MARK 1 MATERIAL MANUFACTURER M-1 RAISED SEAM METAL ROOF PURE FREEFORM E-1 EIFS FINE/LIMESTONE TEXTURE DRYVIT E-2 EIFS FINE/LIMESTONE TEXTURE E-3 E-4 TEXTURE/FINISH SIZE 20" O.C., 1" HIGH COLOR OILED HAIRLINE, 15-0016-1 FINE/LIMESTONE TEXTURE - MATCH BENJAMIN MOORE: A 0844 ROMAN HOLIDAY DRYVIT FINE/LIMESTONE TEXTURE - MATCH BENJAMIN MOORE: A 1827 HALE VILLAGE STENCILING - - - MATCH BENJAMIN MOORE: 271 BARLEY GRASS EIFS FINE/LIMESTONE TEXTURE DRYVIT FINE/LIMESTONE TEXTURE - MATCH BENJAMIN MOORE: A 0864 AUTUMN HAZE 1 S-1 LIMESTONE HAUSSMANN COTE D'AZUR C-1 EXTERIOR METAL SOFFIT PANELS PURE FREEFORM HONED 3/8" - 9" SPACING 1 PLN CHK CMM 05.18.2015 NO DESCRIPTION DATE 1 REVISIONS 1 DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 136074 AJD MMJ 2015 RIM ARCHITECTS LLC BLUE/GREY OA007 DWG NO: A601 SHEET FOUNDATION NOTES A DESIGN CRITERIA 1 A. FLAT ROOF SHEATHING (SLOPE 2:12 OR LESS): â" T&G APA RATED SHEATHING (40/20) EXP 1 WITH 10d @ 6"oc EDGES (PEN) AND 12"oc FIELD UNO ON PLANS. LAY PERPENDICULAR TO FRAMING MEMBERS. BLOCK EDGES WITH 2x4 LAID FLAT WHERE NOTED ON THE PLANS AND DETAILS. NO PANELS LESS THAN 24" WIDE SHALL BE USED. STAGGER SHEETS B. SLOPING ROOF SHEATHING (SLOPE GREATER THAN 2:12): á" APA RATED SHEATHING (32/16) EXP 1 WITH 10d @ 6"oc EDGES (PEN) AND 12"oc FIELD UNO ON PLANS. LAY PERPENDICULAR TO FRAMING MEMBERS. PROVIDE SHTG CLIPS AT UNSUPPORTED EDGES UNLESS NOTED TO BE BLOCKED ON PLANS. NO PANELS LESS THAN 24" WIDE SHALL BE USED. STAGGER SHEETS C. FLOOR SHEATHING: ã" T&G APA RATED SHEATHING (48/24) EXP 1 WITH 10d @ 6"oc EDGES (PEN) AND 12"oc FIELD UNO ON PLANS. LAY PERPENDICULAR TO & GLUE TO FRAMING MEMBERS IMMEDIATELY PRIOR TO FULL NAILING (DO NOT SPOT NAIL). BLOCK EDGES WITH 2x4 LAID FLAT AS NOTED ON THE PLANS AND DETAILS. NO PANELS LESS THAN 24" WIDE SHALL BE USED. STAGGER SHEETS ALL SHEATHING SHEETS SHALL HAVE É" GAP AT ALL EDGES & JOINTS. 3. ABBREVIATIONS ANCHOR BOLT ABOVE AIR CONDITIONING ADJACENT ADDITIONAL ALTERNATE ALUMINUM ARCHITECT AT BUILDING BLOCK/BLOCKING BELOW BEAM BOUNDARY NAIL BOTTOM BEARING BETWEEN BUILT-UP BEYOND AMERICAN STANDARD CHANNEL CANT CANTILEVER CARRIAGE BOLT CB CIP CAST IN PLACE CGL CERTIFIED GLUED LUMBER CONTROL JOINT CJ CENTERLINE ¢ CJP COMPLETE JOINT PENETRATION CEILING CLG CLEAR CLR COL COLUMN COLLECTOR COLL CONCRETE CONC CONNECTION CONN CONTINUOUS CONT COORD COORDINATE/ COORDINATION CONCRETE MASONRY UNIT CMU COUNTERSINK CSK CUT WASHER CW DOUBLE DBL DCW DEMAND CRITICAL WELD DOUGLAS FIR DF DIAMETER DIA or ø DIAGONAL DIAG DIMENSION DIM DOWEL JOINT DJ DEAD LOAD DL DOWN DN DITTO DO DRAWING DWG DWL DOWEL EACH EA EACH END EE EACH FACE EF ELECTRICAL ELEC ELEVATOR/ELEVATION ELEV EMBEDMENT EMBED EQUAL EQ EQUIPMENT EQUIP ES EACH SIDE EACH WAY EW EXIST or (E) EXISTING EXPANSION EXP EXT EXTERIOR FOUNDATION FDN FINISH FIN FINISH GRADE FG FLI FERRULE LOOP INSERT FLOOR FLR FACE NAIL FN FOC FACE OF CONCRETE FACE OF MASONRY FOM FACE OF STUD FOS FRAMING FRMG FS FAR SIDE FOOTING FTG GAGE or GAUGE GA GALVANIZED GALV AB ABV AC ADJ ADDL ALT ALUM ARCH @ BLDG BLK/BLKG BLW BM BN BOT BRG BTWN BU BYND C GB GLB GR HD HDR HGR HK HORIZ HS HSB HSFB HSG HSH HSS HT ID IJ INT JST JT KP Lb or # LGMF LGMFC LL LLH LLV LOC LS LSL LVL MAX MB MBM MC MECH MEZZ MF MFR MIN MISC MIW MTL (N) NIC NO or # NS NSG NTS O/ OC OD OH OPNG OPP OW OWT £ PA PDP PEN PERP SHTG PLF PNL PJP PSF PSI PSL PTB PTDF GRADE BEAM GLUE LAMINATED BEAM GRADE HOLD DOWN HEADER HANGER HOOK HORIZONTAL HIGH STRENGTH HIGH STRENGTH BOLT HIGH STRENGTH FRICTION BOLT HIGH STRENGTH GROUT HORIZONTAL SLOTTED HOLE HOLLOW STRUCTURAL SECTION HEIGHT INSIDE DIAMETER I SHAPED WOOD BUILT UP TRUSS INTERIOR JOIST JOINT KING POST STEEL ANGLE POUND(s) LIGHT GAGE METAL FRAMING LIGHT GAGE METAL FRAMING CONTRACTOR LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATION LAG SCREW LAMINATED STRAND LUMBER LAMINATED VENEER LUMBER MAXIMUM MACHINE BOLT METAL BUILDING MANUFACTURER MISCELLANEOUS CHANNEL MECHANICAL MEZZANINE MOMENT FRAME MANUFACTURER MINIMUM MISCELLANEOUS MALLEABLE IRON WASHER METAL NEW NOT IN CONTRACT NUMBER NEAR SIDE NON-SHRINK GROUT NOT TO SCALE OVER ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE OTHERWISE OPEN WEB TRUSS PLATE or PROPERTY LINE POST ABOVE POWDER DRIVEN PINS PLYWOOD EDGE NAIL PERPENDICULAR PLYWOOD POUNDS PER LINEAR FOOT PANEL PARTIAL JOINT PENETRATION POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PARALLEL STRAND LUMBER PANEL TIE BAR PRESSURE TREATED DOUGLAS FIR PT R RBS RFTR REF REINF REQD RET REV RF RWD S SAD SB SC SCBF SCD SCHED SED SEOR SFRS SHTG SIM SKYLT SMF SMS SMD SOG SPCG SPD SPEC SQ SS STGR STD STIFF STL STRUCT SW SYM T&B T&G THK THRD THRU TL TN TOC TOF TOM TOP TOS TOT TU TYP UNO VERT VIF VSH W W/ W/O WD WHS WLD WP WS WT WTS WWR POINT RADIUS REDUCED BEAM SECTION RAFTER REFERENCE REINFORCING REQUIRED RETAINING REVISION ROOF REDWOOD AMERICAN STANDARD BEAM SEE ARCHITECTURAL DRAWINGS SOLID BLOCK SLIP CRITICAL SPECIAL CONCENTRIC BRACED FRAME SEE CIVIL DRAWINGS SCHEDULE SEE ELECTRICAL DRAWINGS STRUCTURAL ENGINEER OF RECORD SEISMIC FORCE RESISTING SYSTEM SHEATHING SIMILAR SKYLIGHT SPECIAL MOMENT FRAME SHEET METAL SCREW SEE MECHANICAL DRAWINGS SLAB ON GRADE SPACING SEE PLUMBING DRAWINGS SPECIFICATION SQUARE SELECT STRUCTURAL or STAINLESS STEEL STAGGERED STANDARD STIFFENER STEEL STRUCTURAL SHEAR WALL SYMMETRICAL TOP AND BOTTOM TONGUE AND GROOVE THICK THREADED THROUGH TOTAL LOAD TOE NAIL TOP OF CONCRETE TOP OF FRAMING TOP OF MASONRY TOP OF PLYWOOD TOP OF STEEL TOTAL TILT UP TYPICAL UNLESS NOTED OTHERWISE VERTICAL VERIFY IN FIELD VERTICAL SLOTTED HOLE WIDE FLANGE STEEL BEAM WITH WITHOUT WOOD WELDED HEADED STUD WELDED WORK POINT/WATERPROOF WOOD SCREW WEIGHT WELDED THREADED STUD WELDED WIRE REINFORCEMENT ALL NAILS SHALL BE COMMON WIRE FULL ROUND HEAD NAILS. 16d SINKER NAILS MAY BE SUBSTITUTED FOR 16d COMMON NAILS AT ROUGH FRAMING UNO. MACHINE-DRIVEN NAILS MEETING SIZE REQUIREMENTS ARE ACCEPTABLE. NAIL MUST NOT BE OVERDRIVEN. SEE 7/S1.2 FOR SHEATHING NAILING REQUIREMENTS. ALL NAILING NOT NOTED OR DETAILED OTHERWISE SHALL BE PER 6/S1.2. NAIL LENGTH TO BE SUFFICIENT TO MEET CBC PENETRATION REQUIREMENTS. NAILS INTO PRESSURE TREATED MATERIAL TO BE HOT DIP GALVANIZED. WIRE NAIL MINIMUM SHANK DIAMETER MINIMUM NAIL LENGTH TYPICAL NAIL APPLICATION, UNO 16d COMMON 16d SINKER 10d COMMON 10d COMMON 8d COMMON 0.162" 0.148" 0.148" 0.148" 0.131" 3Ï" 3Ë" 3" 2Ï" 2Ï" FRAMING FRAMING FRAMING SHEATHING SHEATHING 4. FOR ROOF DRAINAGE, TOP OF FRAMING BETWEEN NOTED POINTS IS A STRAIGHT LINE. 5. ALL MECHANICAL SUPPLY AND RETURN OPENINGS TO BE BETWEEN FRAMING UNO. 6. HSS OR PIPE COLUMNS IN STUD WALLS ARE TO BE TRIMMED PER 4/S1.2. REFER TO PLANS AND DETAILS FOR OTHER REQUIREMENTS. 7. JOISTS AND RAFTERS ARE PER PLAN. UNLESS NOTED OTHERWISE, PROVIDE "LU" HANGER AT FLUSH FRAMING AND "HU" HANGER WHERE HANGER IS SHOWN SKEWED PER PLAN AND/OR HANGER SEAT IS INDICATED TO BE SLOPED. HANGER SIZE TO BE CORRECT FULL SIZE FOR JOIST SIZE (I.E. LU210 FOR 2x10). HANGERS FOR PANELIZED ROOF CONSTRUCTION ARE PER PLAN. 8. PROVIDE SOLID BLOCKING @ 8'-0"oc MAX FOR ALL 2x12 JOISTS. 9. PROVIDE ADDITIONAL JOIST BELOW ALL OR ADJACENT TO NON-STRUCTURAL WALLS PARALLEL TO FRAMING, UNO. 10. ROUND HOLES IN STEEL PLATES TO BE È" OVERSIZE. SLOTTED HOLES IN STEEL PLATES SHALL BE È" WIDER THAN THE BOLT DIAMETER AND HAVE A LENGTH OF 2 TIMES THE BOLT DIAMETER. THE DIRECTION OF THE SLOTTED LENGTH IS INDICATED ON THE DETAILS (VSH OR HSH). INSTALL BOLT AT THE CENTER LINE OF THE HOLE. BOLT HOLES IN WOOD SHALL BE ROUND AND Ý" OVERSIZE. CUT OFF BOLT THREADED END FLUSH WITH NUT WHEN REQUIRED BY FINISHES AND 1" MAXIMUM FROM NUT OTHERWISE. PROVIDE STANDARD CUT WASHERS UNDER HEAD AND NUT WHERE BOLT BEARS ON WOOD. USE PLATE OR MALLEABLE IRON WASHERS AT EXPOSED CONDITIONS OR AS INDICATED. 11. ALL BOLTED OR NAILED STRAP CONNECTIONS SHALL HAVE AN EQUAL NUMBER OF BOLTS OR NAILS EACH SIDE OF THE SPLICE JOINT. THE FIRST BOLT OR NAIL FROM EACH SIDE OF THE SPLICED OR STRAPPED MEMBER SHALL BE EQUIDISTANT FROM THE SPLICE. STRAPS USING 16d NAILS ON 2x MATERIAL TO BE INSTALLED ON THE 1Ï" EDGE OF THE MEMBER. 12. THE CONTRACTOR SHALL VERIFY THAT THE MOISTURE CONTENT OF ALL FRAMING LUMBER AND SHEATHING MEET THE REQUIREMENTS OF THE SPECIFICATIONS AT THE TIME OF INSTALLATION AND AT CLOSE-IN. THE CONTRACTOR SHALL PROVIDE ALLOWANCE FOR DIFFERENTIAL SHRINKAGE BETWEEN FLOORS, ETC. EARTHQUAKE DATA: ROCKRIDGE GEOTECHNICAL REPORT NO. 13-622 DATED: 24 FEBRUARY 2014 2. USE 5/8" DIAMETER x 12" (18" AT CURBS) ANCHOR BOLTS (AB) AT 48"oc WHERE NOT OTHERWISE NOTED. MINIMUM EMBEDMENT INTO CONCRETE IS 7" (EXCLUDING CURB) UNLESS DETAILED OTHERWISE. ANCHOR BOLTS ARE TO BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. SEE SHEAR WALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. MINIMUM TWO ANCHOR BOLTS PER SILL PIECE. 3. TYPICAL SLAB ON GRADE (FOR PATCHING AND REPLACEMENT): 5" CONCRETE REINFORCED WITH #4 @ 18"oc AT MID-DEPTH OVER VAPOR RETARDER (PER SPECIFICATIONS) AND 4" MINIMUM FREE DRAINING COMPACTED ROCK PER SPECIFICATIONS ON SUBGRADE PER THE GEOTECHNICAL RECOMMENDATIONS, AND AS APPROVED BY THE GEOTECHNICAL ENGINEER. DO NOT DRIVE CONCRETE TRUCKS OR LARGE SCREED MACHINES ON VAPOR BARRIER WITHOUT ADDITIONAL BUFFER MATERIAL AND APPROVAL FROM THE STRUCTURAL ENGINEER. NON-STRUCTURAL COMPONENT SEISMIC FORCE PARAMETERS: STEEL ORDINARY MOMENT FRAMES DETAILED PER AISC 341 WITH PERMITTED HEIGHT INCREASE (i.e. TOWER); AND CANTILEVER ELEMENTS UNBRACED OR BRACED BELOW CENTER OF MASS (i.e. TRELLIS, PLANTERS & SUPPORTS, SIGNS, ETC.) aæ = 2.5 Ræ = 2.5 ÀÛ = 2.0 (TOWER) ÀÛ = 2.5 (ALL OTHER COMPONENTS) Cd = 2.5 (APPLICABLE AT TOWER ONLY) z/h = 1.0 Iæ = 1.0 Fæ = 1.08Wæ SPECIAL INSPECTION BY OWNERS TESTING AGENCY 1. SHOP FABRICATION OF STRUCTURAL LOAD-BEARING MEMBERS AND ASSEMBLIES PER CBC SECTION 1704.2.5 OR ALTERNATIVELY, APPROVED FABRICATORS SHALL SUBMIT A CERTIFICATE OF COMPLIANCE PER CBC SECTION 1704.2.5.2 INCLUDING GLULAM BEAM INSPECTION CERTIFICATES. 2. STRUCTURAL STEEL CONSTRUCTION PER CBC SECTIONS 1705.2, 1705.11.1, 1705.12.2, AND TABLE 1705.2.2 INCLUDING MATERIAL IDENTIFICATION, SHOP AND FIELD WELDING, AND INSTALLATION OF HIGH-STRENGTH BOLTS. 3. CONCRETE CONSTRUCTION PER CBC SECTIONS 1705.3, 1705.12.1, AND TABLE 1705.3 INCLUDING FORMWORK, REINFORCING STEEL, CAST-IN-PLACE BOLTS, MIX DESIGNS, CONCRETE SAMPLES, AND PLACEMENT FOR ALL CONCRETE. REINFORCING DOWELS FROM FOOTINGS TO RETAINING WALLS SHALL BE INSPECTED PRIOR TO PLACEMENT OF FOOTING CONCRETE AND WALL GROUT OR CONCRETE. CONTINUOUS OR ISOLATED SPREAD FOOTINGS WITH DESIGN STRENGTH NO GREATER THAN 2500 PSI, NON-STRUCTURAL SLABS ON GRADE, AND EXTERIOR FLATWORK DO NOT REQUIRE SPECIAL INSPECTION PER CBC SECTION 1705.3. 4. WOOD CONSTRUCTION PER CBC SECTIONS 1705.5 AND 1705.11.2 INCLUDING NAILING, BOLTING, AND ANCHORING OF ALL DRAG STRUTS; TOP PLATE SPLICES, LEDGER SPLICES, SIMPSON HARDWARE, BRACES, AND HOLDOWNS; AND NAILING, BOLTING, AND ANCHORING OF ALL SHEARWALLS, SHEAR PANELS, AND DIAPHRAGMS WHERE THE FASTENER SPACING OF THE SHEATHING IS 4" APART OR LESS. 5. SOILS PER CBC SECTION 1705.6, TABLE 1705.6, AND THE APPROVED SOILS REPORT INCLUDING SUBGRADE PREPARATION, FOUNDATION BEARING MATERIALS AND DEPTH OF EXCAVATIONS, AND VERIFICATION, PLACEMENT AND TESTING OF CONTROLLED FILL. 6. SPECIAL CASES PER CBC SECTION 1705.1.1 AND PRODUCT ICC REPORTS FOR ALL STRUCTURAL MATERIALS AND SYSTEMS REQUIRED TO BE INSTALLED IN ACCORDANCE WITH ADDITIONAL MANUFACTURER'S INSTRUCTIONS THAT PRESCRIBE REQUIREMENTS NOT CONTAINED IN THE CBC OR REFERENCED STANDARDS: 1. POST-INSTALLED ANCHOR BOLTS IN CONCRETE 2. VERIFICATION OF SATURATED WEIGHT OF PLANTERS. 13. VENTING IS REQUIRED IN ENCLOSED FRAMING AREAS, SAD. DRILL BLOCKING AND LEDGERS AND PROVIDE SKIP BLOCKING AS DETAILED. 14. SAD FOR CEILING INFO. A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com MAXIMUM ANTICIPATED STORY DRIFT = 0.02 X HEIGHT PROVIDE DEFORMATION COMPATIBILITY PER ASCE 7 SECTION 12.12.5 FOR NON-STRUCTURAL ITEMS, INCLUDING CLADDING, STAIRS, GLAZING, ETC. 5. TOP OF FOOTING ELEVATION TO MATCH EXISTING UNLESS NOTED OTHERWISE. SPECIAL INSPECTIONS AND TESTING SHALL BE PERFORMED BY AN APPROVED AGENCY IN ACCORDANCE WITH CBC CHAPTER 17 AND THE STATEMENT OF SPECIAL INSPECTIONS AS REQUIRED BY CBC SECTIONS 1704.2.3 AND 1704.3 FOR BUILDING STRUCTURAL ELEMENTS SUMMARIZED AS FOLLOWS: RIM BUILDING SEISMIC FORCE RESISTING SYSTEM(S): 4. PROVIDE CONTROL JOINTS (OR CONSTRUCTION/DOWEL JOINTS AT CONTRACTOR'S OPTION) AS SHOWN ON PLAN (15'-0"oc MAX. UNO) PER 4/S1.1. INSTALL JOINTS TO DIVIDE SLAB INTO RECTANGULAR AREAS WITH LONG DIMENSION LESS THAN 1.5 x SHORT DIMENSION. INSTALL JOINTS AT FACE OF STUDS OF WALL WHERE POSSIBLE. SUBMIT JOINT LAYOUT PLAN FOR REVIEW PRIOR TO PLACEMENT. D 2013 CALIFORNIA CODE OF REGULATIONS, TITLE 24, PART 2 (CBC) 80 PSF (REDUCIBLE) + 20 PSF PARTITION 20 PSF (REDUCIBLE) II ULTIMATE WIND SPEED (3 SEC GUST) IN MPH: 110 WIND EXPOSURE: C INTERNAL WIND PRESSURE COEFFICIENT (GCPI) = ±0.18 MIN DESIGN PRESSURE FOR COMPONENTS AND CLADDING BY OTHERS: 42 PSF (W), AND AS REQD BY ASCE 7 SEISMIC IMPORTANCE FACTOR, Ió: 1.0 MAPPED SPECTRAL RESPONSE ACCELERATIONS: SÅ¡ = 1.5; Sþ = 0.6 SITE CLASS: D SPECTRAL RESPONSE COEFFICIENTS: SŽš = 0.9; SŽþ = 0.96 SEISMIC DESIGN CATEGORY: D BUILDING SEISMIC FORCE RESISTING SYSTEM(S): WOOD FRAMED SHEAR WALLS RESPONSE MODIFICATION FACTOR(S): R = 6.5 SEISMIC RESPONSE COEFFICIENT(S), CÅ¡ = 0.138 (LRFD) DEFLECTION AMPLIFICATION FACTOR: Cd = 4.0 STEEL ORDINARY MOMENT RESISTING FRAMES RESPONSE MODIFICATION FACTOR(S): R = 3.5 SEISMIC RESPONSE COEFFICIENT(S), CÅ¡ = 0.257 (LRFD) DEFLECTION AMPLIFICATION FACTOR: Cd = 5.5 STEEL SPECIAL MOMENT RESISTING FRAMES RESPONSE MODIFICATION FACTOR(S): R = 8.0 SEISMIC RESPONSE COEFFICIENT(S), CÅ¡ = 0.113 (LRFD) DEFLECTION AMPLIFICATION FACTOR: Cd = 3.0 ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE B 1 PERMIT SET GENERAL NOTES 1. REFER TO SHEETS S1.1, S1.2, S1.3, S1.4, S5.1 AND S5.2 FOR STANDARD DETAILS OF CONSTRUCTION. REFER TO THE PROJECT SPECIFICATIONS FOR MATERIALS AND METHODS. 2. BUILDING DIMENSIONS SHOWN ARE FOR GENERAL REFERENCE ONLY. SEE ARCHITECTURAL DRAWINGS (SAD) FOR ALL ACTUAL BUILDING DIMENSIONS. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER SO CLARIFICATION CAN BE MADE PRIOR TO COMMENCING WORK. ALL DIMENSIONS RELATED TO EXISTING CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND SUBMITTED IN WRITING TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. 3. STRUCTURAL DRAWINGS SHALL NOT BE SCALED. ALL DIMENSIONS AND FIT SHALL BE DETERMINED AND VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING WORK. 4. DETAILS NOT FULLY OR SPECIFICALLY SHOWN SHALL BE OF SAME NATURE AS OTHER SIMILAR CONDITIONS. 5. COORDINATION OF MECHANICAL, ELECTRICAL, PLUMBING, AND SITE UTILITY SYSTEMS WITH THE STRUCTURAL SYSTEM IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. USE DETAILS 2/S1.1, 3/S1.1, 5/S1.1, 1/S1.2 AND 2/S1.2. AT CONDITIONS WHERE THESE DETAILS DO NOT APPEAR TO APPLY, NOTIFY THE STRUCTURAL ENGINEER PRIOR TO INSTALLATION. AT CONDITIONS WHERE FIELD MODIFICATIONS OF MECHANICAL, ELECTRICAL, PLUMBING, OR SITE UTILITIES AFFECT STRUCTURAL SYSTEMS, NOTIFY STRUCTURAL ENGINEER PRIOR TO INSTALLATION. 6. VERIFY WEIGHTS AND LOCATIONS OF NON-STRUCTURAL COMPONENTS (SUCH AS PLANTERS) PRIOR TO PLACEMENT. WEIGHTS SHALL NOT EXCEED THOSE SHOWN ON STRUCTURAL DRAWINGS. CONTRACTOR TO VERIFY SIZES AND WEIGHTS PRIOR TO INSTALLATION OF SPECIAL FRAMING. 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 TYPICAL SHEATHING: DESIGN CRITERIA: FLOOR LIVE LOAD: ROOF LIVE LOAD: RISK CATEGORY: WIND DATA: ADDRESS: 2. 1. ALL SOILS WORK SHALL BE DONE IN ACCORDANCE WITH THE SPECIFICATIONS AND THE REQUIREMENTS OF THE GEOTECHNICAL REPORT NOTED BELOW, AND CHAPTER 18 OF THE CBC. ALL FOUNDATIONS SHALL BEAR ON FIRM, UNDISTURBED, NATIVE SOILS OR ENGINEERED FILL AT OR EXCEEDING DEPTHS SHOWN ON THE DRAWINGS. ENGINEERED FILL TO BE COMPACTED PER GEOTECHNICAL REPORT. INCREASE FILL AND OR FOOTING DEPTH AS REQUIRED BY GEOTECHNICAL ENGINEER. ALL FOOTING EXCAVATIONS SHALL BE AS NEAT AS PRACTICABLE. MAXIMUM OVER EXCAVATION IN WIDTH SHALL BE LESS THAN 12 INCHES OR 25% OF FOOTING WIDTH, WHICH EVER IS LESS. 6 INCHES MAXIMUM PER SIDE. LARGER OVER-EXCAVATIONS IN WIDTH SHALL BE FILLED WITH ADDITIONAL REINFORCED CONCRETE AS DIRECTED BY THE ENGINEER, OR FORMWORK SHALL BE PROVIDED. OVER-EXCAVATIONS IN DEPTH MAY BE FILLED WITH LEAN CONCRETE OR COMPACTED APPROVED BACKFILL. ALL LOOSE SOILS SHALL BE REMOVED FROM EXCAVATIONS PRIOR TO PLACEMENT OF REINFORCING OR CONCRETE. GEOTECHNICAL REPORT BY: TCCM TOWER RELOCATION ALL BEAMS AND JOISTS (EXCLUDING I JOISTS) SHALL BE SEAT CUT FOR FULL UNIFORM BEARING AT SUPPORTS, INCLUDING BEAM SEATS AND COLUMN CAPS. PROJECT TITLE: 1. GENERAL NOTES AND SPECIFICATIONS C SHEET TITLE: WOOD FRAMING NOTES 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION E OWNER: 1 7. SHORING AND BRACING DESIGN, MATERIALS AND INSTALLATION SHALL BE PROVIDED BY THE GENERAL CONTRACTOR, AND SHALL BE ADEQUATE FOR ALL LOADS. LEAVE IN PLACE AS LONG AS MAY BE REQUIRED FOR SAFETY AND UNTIL FINAL STRUCTURAL CONSTRUCTION IS COMPLETED. 8. SPECIAL INSPECTIONS ARE REQUIRED PER D/S0.1 AND THE TESTING AND INSPECTION FORM. 9. STRUCTURAL OBSERVATION PER CBC SECTION 1704.5 IS NOT REQUIRED. NOTIFY ZFA FOR GENERAL REVIEW OF: - MINIMUM FOOTING SIZE AND REINFORCING STEEL - WOOD SHEAR WALLS, SHEAR PANELS AND FLOOR/ROOF DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORAGE AND OTHER FASTENING TO OTHER COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. NOTIFY ZFA FOR REVIEW PRIOR TO COVERING ABOVE LISTED WORK. PROVIDE 2 WORKING DAYS MINIMUM SCHEDULING NOTICE PRIOR TO REVIEW DATE. 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S0.1 SHEET F 3,000 (4,000 AT 56 DAYS) 1"x#4 FOUNDATIONS 3,000 (DESIGNED FOR 2,500) 1"x#4 0.45 0.53 6.1 5.0 2. NON-STRUCTURAL LEAN CONC FOR FTG BACKFILL EXTERIOR SLAB ON GRADE (WALKS AND PATIOS) 2. - - - 3.0 3. 2,500 1"x#4 0.55 4.5 CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF CBC SECTIONS 1705 AND 1903, ACI 318 CHAPTER 5, AND THESE SPECIFICATIONS. CEMENT TO BE IN ACCORDANCE WITH ASTM C150 TYPE II. AGGREGATE TO MEET ASTM C33. 3. CONCRETE MIX DESIGN FOR INTERIOR SLABS ON GRADE TO HAVE 25% TO 35% FLY ASH TYPE F SUBSTITUTED FOR CEMENT ON A 1 TO 1 RATIO. REPLACE 200 POUNDS OF SAND WITH 200 POUNDS Í"(-) AGGREGATE TO REDUCE TOTAL SAND. 4. UNDER SLAB VAPOR RETARDER TO BE ASTM E1745 CLASS A; 15 MILS MINIMUM THICKNESS; 0.01 U.S. PERMS MAXIMUM PERMEANCE. INSTALL PER ASTM E1643 AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE "STEGO WRAP VAPOR BARRIER (15MIL)" OR APPROVED EQUIVALENT. RETARDER SHALL EXTEND TO FOOTINGS BUT NOT TO BOTTOM OF FOOTING OR INTO A COLD JOINT. 5. 6. 7. REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 OR A706 GRADE 60. BARS #3 AND SMALLER MAY BE ASTM A615 GRADE 40. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. SECURELY TIE REBAR IN PLACE PRIOR TO CONCRETE PLACEMENT. SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO INSTALLATION. WELDED REINFORCING STEEL SHALL BE ASTM A706 OR A615 MEETING CARBON REQUIREMENTS OF AWS D1.4. WELDING SHALL CONFORM WITH AWS D1.4. WELDED WIRE REINFORCEMENT SHALL CONFORM WITH ASTM A185 AND SHALL BE LAPPED 12" MINIMUM. SLABS, BEAMS, WALLS AND OTHER CONCRETE SHALL BE KEPT CONTINUOUSLY WET FOR 48 HOURS, AFTER PLACEMENT, AND SHALL BE KEPT DAMP FOR 7 DAYS AFTER PLACEMENT. SLABS SHALL HAVE CURE/SEALER APPLIED IMMEDIATELY AFTER FINISHING IF OTHER FINISHES ARE NOT AFFECTED. WHEN CURE SEALER CAN NOT BE APPLIED, SLAB SHALL BE KEPT CONTINUOUSLY WET OR COVERED WITH CURING PAPER. CURE SHALL BE OF A TYPE THAT WILL NOT BE DETRIMENTAL TO SEALERS TO BE APPLIED LATER. ANCHOR BOLTS - ASTM F1554 GRADE 36 THREADED ROD WITH DOUBLE NUTS OR ASTM A307 HEADED BOLTS. (NO "J" OR "L" BOLTS EXCEPT AT WOOD SILL PLATES). SECURELY TIE ANCHOR BOLTS IN PLACE PRIOR TO CONCRETE POUR. 8. MECHANICAL COUPLERS FOR REINFORCING STEEL TO BE "L-SERIES BAR LOCK" BY DAYTON SUPERIOR (ESR-2495) OR EQUAL COUPLER WITH ICC REPORT, UNO. 9. CONCRETE EXPANSION ANCHORS ARE SIMPSON STRONG BOLT 2 (ESR-3037) OR HILTI KWIK BOLT TZ (ESR-1917). CONCRETE SCREW ANCHORS ARE SIMPSON TITEN HD (ESR-2713) OR HILTI KH-EZ (ESR-3027). CONCRETE EPOXY DOWEL ADHESIVE IS SIMPSON SET-XP (ESR-2508) OR HILTI HIT-RE 500-SD (ESR-2322). CONCRETE INSERTS AND FERRULE LOOP INSERTS ARE BY BURKE CONCRETE COMPANY. STRUCTURAL STEEL 1. STEEL GRADES: WF & WT SHAPES.......................................... C SHAPES, L SHAPES & PLATES................. PIPES ............................................................. ROUND HSS .................................................. SQUARE AND RECTANGULAR HSS ............ MACHINE BOLTS (MB) .................................. HIGH STRENGTH BOLTS (HSB) ................... ANCHOR RODS ............................................. NUTS............................................................... WASHERS....................................................... WELDED HEADED/THREADED STUDS...... DEFORMED BAR ANCHORS........................ ASTM A992 OR A572 GRADE 50 ASTM A36 OR A572 GRADE 50 ASTM A53 GRADE B ASTM A500 GRADE B Fü=42KSI ASTM A500 GRADE B Fü=46KSI ASTM A307 OR F1554 GRADE 36 ASTM A325 UNO ASTM F1554 GR36 OR A307 UNO ASTM A563 ASTM F436 ASTM A108 Fü=51KSI ASTM A496 2. WORKMANSHIP AND DETAILS SHALL CONFORM TO THE AISC SPECIFICATIONS AND THE CBC UNLESS NOTED OTHERWISE. 3. BOLT HOLES SHALL BE È" LARGER IN DIAMETER THAN THE BOLT. ANCHOR BOLT HOLES SHALL BE É" LARGER IN DIAMETER THAN THE ANCHOR BOLT. 4. WELDING ELECTRODES SHALL MEET AWS REQUIREMENTS AND ELECTRODES SHALL BE E70XX FOR SHIELDED METAL ARC, F7XX-EXXX FOR SUBMERGED ARC (SHOP WELDS ONLY), ER70S-X FOR GAS METAL ARC AND E7XT-XX FOR FLUX CORE (UNLESS NOTED OTHERWISE). 5. ALL STRUCTURAL WELDS SHALL BE INSPECTED AND CERTIFIED BY A QUALIFIED TESTING AGENCY. CERTIFICATION SHALL BE SUBMITTED TO THE ARCHITECT AND THE BUILDING DEPARTMENT. 6. 7. TEMPORARY SHORING AND BRACING SHALL BE USED AND SHALL BE ADEQUATE FOR ALL LOADS TO WHICH IT MAY BE SUBJECTED. LEAVE TEMPORARY BRACING AND SHORING IN PLACE AS LONG AS MAY BE REQUIRED FOR SAFETY, AND UNTIL FINAL FRAMING CONSTRUCTION IS COMPLETED. HIGH STRENGTH GROUT: ASTM C1107, NON-SHRINK, NON-METALLIC AGGREGATE TYPE, CAPABLE OF DEVELOPING MINIMUM COMPRESSIVE STRENGTH OF 7,000 PSI AT 28 DAYS WHEN PLACED IN A FLUID STATE. PROVIDE "MASTERFLOW 928" MANUFACTURED BY BASF. 8. SAD FOR FINISHES ON STEEL FRAMING. STEEL FRAMING WITH EXTERIOR EXPOSURE SHALL BE HOT-DIP GALVANIZED. ALL CONNECTION HARDWARE AT EXTERIOR EXPOSURE FRAMING SHALL BE HOT-DIP GALVANIZED. FIELD TOUCH-UP WITH ZINC 1 RICH PRIMER AFTER ERECTION 9. CONTRACTOR TO SUBMIT SHOP DRAWINGS PRIOR TO FABRICATION FOR REVIEW. GENERAL CONTRACTOR TO REVIEW SHOP DRAWINGS PRIOR TO SUBMISSION TO ARCHITECT/ENGINEER. 10. WELDING OF THREADED STUDS, HEADED STUDS, AND DEFORMED BAR ANCHORS SHALL BE FULL-FUSION ARC WELDS CONFORMING TO AWS D1.1. 4. 5. 6. FÄ‚ (PSI) E (PSI) 1200 1350 1000 900 900 700 900 170 170 180 180 180 180 180 1.6x10ì 1.6x10ì 1.7x10ì 1.6x10ì 1.6x10ì 1.4x10ì 1.6x10ì IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT THE MAXIMUM MOISTURE CONTENT OF WOOD AT THE TIME OF INSTALLATION SHALL BE NOT MORE THAN 19%. NAILS TO BE OF COMMON WIRE WHERE NAILING IS SPECIFIED ON THE DRAWINGS. 16d SINKER NAILS 0.148 x 3Ë" MAY BE SUBSTITUTED FOR 16d COMMON NAILS UNO. PRE-DRILL NAIL HOLES WHERE WOOD TENDS TO SPLIT. NAILS AS SPECIFIED ON PLANS AND INCLUDING IN PTDF MATERIAL CONTAINING AMMONIA IN EXTERIOR APPLICATIONS SHALL BE TYPE 304 OR 316 STAINLESS STEEL. NAILS USED IN EXTERIOR APPLICATIONS OR IN INTERIOR PTDF SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153. 5. ALL STUDS TO BE CONTINUOUS. ALL TRACKS IN HEADERS AND SILLS TO BE CONTINUOUS SINGLE-PIECE BETWEEN JAMB STUDS OR PARAPET POSTS. 6. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING. SCREWS OR WELDS NOT SHOWN SHALL BE OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. ALL WELDS OF GALVANIZED STEEL SHALL BE TOUCHED-UP WITH A ZINC-RICH PAINT. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. WOOD SCREWS SHALL CONFORM TO ANSI/ASME B18.6.1. PROVIDE PILOT HOLE 70% OF DIAMETER OF SCREW SHANK WHERE FASTENING HARDWOOD TIMBER SPECIES OR WHERE WOOD TENDS TO SPLIT. MINIMUM PENETRATION IS (10) DIAMETERS, UNO. 9. EXPANSION ANCHOR OR SCREW ANCHOR SIZE AND EMBEDMENT ARE AS REQUIRED PER DRAWINGS. MINIMUM STEEL EDGE DISTANCE IN TRACK IS 2x ANCHOR DIAMETER AND MINIMUM SPACING IS 3x ANCHOR DIAMETER UNO. SEE EXPANSION OR SCREW ANCHOR SCHEDULE FOR CONCRETE REQUIREMENTS. FOR EXPANSION ANCHOR THROUGH METAL TRACK, USE 3" SQUARE x Ë" PLATE WASHER (OR EQUIVALENT ROUND WASHER) AT TRACK. DRILL HOLE IN PLATE WASHER FOR EXPANSION ANCHOR AS NEEDED TO ACHIEVE MINIMUM EDGE DISTANCES. BOLTS SHALL BE UNFINISHED MACHINE BOLTS PER ASTM A307. NUTS SHALL BE PER ASTM A563 AND OF STANDARD SIZE UNLESS NOTED OTHERWISE. LENGTH OF BOLTS SHALL BE SUCH THAT THE BOLT PROJECTION IS NOT LESS THAN È" NOR MORE THAN Ï" PAST END OF NUT. BOLT HOLES IN WOOD SHALL BE Ý" LARGER THAN BOLT SIZES (UNO). PROVIDE STANDARD CUT WASHERS UNDER HEAD AND NUT WHERE BOLT HEADS WOULD BEAR ON WOOD. USE MALLEABLE IRON WASHERS WHERE EXPOSED TO VIEW OR NOTED. NUTS SHALL BE TIGHTENED WHEN PLACED AND RETIGHTENED BEFORE CLOSING IN OF WALLS OR OTHER CONSTRUCTION. DO NOT CRUSH WOOD WHEN TIGHTENING. BOLTS AS SPECIFIED ON PLANS AND THOSE IN CONTACT WITH PTDF MATERIAL CONTAINING AMMONIA IN EXTERIOR APPLICATIONS SHALL BE TYPE 304 OR 316 STAINLESS STEEL. ALL OTHER BOLTS USED IN EXTERIOR APPLICATIONS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153. 8. DECKING MATERIAL AND FRAMING EXPOSED TO WEATHER TO BE PTDF AWPA "USE CATEGORY" UC3B OR REDWOOD, SAD. 9. WOOD ADHESIVE SHALL BE WATER-PROOF, CARTRIDGE DISPENSED, MEETING APA PRODUCT SPECIFICATION AFG-01 OR ASTM D3498. LOCTITE "PL PREMIUM" OR EQUAL. FOR USE AT SUBFLOOR SHEATHING AND WHERE SPECIFICALLY NOTED FOR USE ON DRAWINGS. PLYWOOD/ORIENTED STRAND BOARD (OSB) SHEATHING 1. STRUCTURAL SHEATHING SHALL CONFORM TO PRODUCT STANDARD PS-1 OR PS-2. ALL PANELS SHALL HAVE AN EXTERIOR EXPOSURE RATING AND BEAR THE TRADEMARK OF THE ENGINEERED WOOD ASSOCIATION (APA). SHEATHING SHEETS SHALL BE SPLICED ALONG CENTERLINE OF FRAMING MEMBER WITH NAILING SPACED NOT LESS THAN Í" FROM EDGE OF SHEETS. MACHINE-PLACED NAILING AND NAILS TO BE APPROVED BY THE ENGINEER PRIOR TO USE. SHEATHING NAILS OF COMMON WIRE WITH FULL ROUND HEADS ARE REQUIRED. OSB WITH EQUIVALENT THICKNESS AND SPAN RATING MAY BE USED IN LIEU OF PLYWOOD CALLED OUT. ALL OSB SHALL CONFORM TO PS-2. COLD FORMED METAL FRAMING 1. YIELD STRENGTHS SHALL BE: Fü = 33,000 PSI 33 & 43 MILS (20 & 18 GAUGE) Fü = 50,000 PSI 54, 68, & 97 MILS (16, 14, & 12 GAUGE) METAL FRAMING TO BE MANUFACTURED BY CURRENT MEMBERS OF "THE STEEL STUD MANUFACTURER'S ASSOCIATION" (SSMA) PER ICC-ES ESR-3064P, THE "CERTIFIED STEEL STUD ASSOCIATION" (CSSA) PER ICC ESR-3016, OR EQUIVALENT - SUBMIT MANUFACTURER'S INFORMATION (ICC REPORTS) AND PRODUCT COMPARISON FOR ENGINEER'S EVALUATION OF ANY SUBSTITUTE. 3. ALL FRAMING MEMBERS SHALL BE GALVANIZED TO G60 MINIMUM (EQUIVALENT COATING SUCH AS G60e NOT ACCEPTABLE). STUDS AND JOISTS SHALL BE FORMED FROM STEEL THAT CORRESPONDS TO THE MINIMUM REQUIREMENTS OF THE AMERICAN IRON AND STEEL INSTITUTE (AISI) STANDARDS. 4. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AISI "SPECIFICATIONS FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS". 5. 4. TYPICAL TRACKS ARE SAME GAUGE (MILS) AS STUD, 43 MILS MINIMUM UNO. FLANGE TO BE 1Ï" MIN. 7. METAL SCREWS (MS) OR (SMS) TO BE PAN-HEAD OR HEX-HEAD, SELF-DRILLING OR IN PREDRILLED HOLE, OF SIZE AS NOTED ON DRAWINGS, AND OF SUFFICIENT LENGTH TO ACHIEVE FULL PENETRATION INTO ALL MEMBERS AT CONNECTIONS (3 - THREAD PENETRATION MINIMUM BEYOND LAST PLY). MINIMUM EDGE DISTANCE AND SPACING IS 1" IN ALL MEMBERS. WOOD AGAINST CMU OR CONCRETE SHALL BE PRESSURE TREATED DOUGLAS FIR (PTDF) PER AWPA STANDARD U1. "USE CATEGORY" UC2 AT INTERIOR. "USE CATEGORY" UC3B AT EXTERIOR (NO GROUND CONTACT). 2. 3. TYPICAL METAL STUDS AND FRAMING ARE PER SCHEDULES 1/S1.3 UNO. SUBMIT SHOP DRAWINGS AND MANUFACTURER'S INFORMATION SHOWING CONFORMANCE TO CRITERIA SHOWN ON DRAWINGS AND SPECIFICATIONS. MINIMUM METAL THICKNESS = 33MILS (20GA). METAL FRAMING CLIPS, HANGERS, ETC. ARE BY SIMPSON STRONG-TIE. NAILING SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS WITH A NAIL PROVIDED FOR EACH PUNCHED HOLE UNO. CONNECTORS AS SPECIFIED ON PLANS AND THOSE IN CONTACT WITH PTDF MATERIAL CONTAINING AMMONIA IN EXTERIOR APPLICATIONS SHALL BE TYPE 304 OR 316 STAINLESS STEEL. ALL OTHER CONNECTORS USED IN EXTERIOR APPLICATIONS OR INTERIOR PTDF SHALL BE HDG (MINIMUM 2.0 oz/SQ FT) OR ZMAX (MINIMUM 1.85 oz/SQ FT PER ASTM A653). IN APPLICATIONS WHERE NON-AMMONIA TREATED WOOD IS DRY WHEN INSTALLED AND WILL REMAIN DRY IN-SERVICE A COATING THICKNESS OF 0.9 oz/SQ FT MAY BE USED. 7. 2. 600 - MEMBER DEPTH IN 1/100" (6") S - MEMBER STYLE - S=STUD, T=TRACK 162 - FLANGE WIDTH IN 1/100" (1Ñ") 54 - MATERIAL THICKNESS IN MILS (0.054") WELDING ELECTRODES SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS) STANDARDS INCLUDING AWS A5.18 (GAS METAL ARC.). TOUCH UP ALL WELDS WITH ZINCRICH PAINT IN COMPLIANCE WITH ASTM A780. 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com 8. POWDER DRIVEN PINS (PDP) TO BE 0.157"ø x MINIMUM 1Ë" LONG HILTI X-U UNO. MINIMUM DISTANCE TO EDGE OF CONCRETE IS 3". MINIMUM SPACING TO BE 4"oc. DO NOT USE PDP AT CONCRETE CURBS. AT STRUCTURAL STEEL USE 0.157"ø xÑ" LONG HILTI X-U UNO. PERMIT SET 10. METAL STUDS TO BE LATERALLY BRACED WITH GYPSUM BOARD BOTH SIDES PER CBC OR BRACED AT 4'-0"oc MAXIMUM PER 1/S1.4. 11. TYPICAL STUD-TO-TRACK CONNECTIONS PER 2/S1.4 UNO. MAXIMUM GAP OF É" IS ALLOWED BETWEEN STUDS AND TRACK AT STANDARD WALLS. TRIM STUDS TO FULLY BEAR. 12. TYPICAL WALL INTERSECTIONS PER 7/S1.4 UNO. 13. PROVIDE LIGHT GAUGE METAL BACKING FOR ARCHITECTURAL FINISHES AND FURNISHINGS, SAD. 14. TYPICAL PUNCHOUTS PER 5/S1.4. 15. WALLS AT SEISMIC SEPARATION JOINTS SHALL BE FRAMED AS EXTERIOR WALLS UNO. G STEEL NOTES 1. COORDINATE TOP OF FOOTING ELEVATIONS AS DETERMINED BY THE CONTRACTOR PER C/S0.1 NOTE #5 1 2. TOP OF STEEL ELEVATIONS ARE TO BE DETERMINED BY THE CONTRACTOR BASED ON ARCHITECTURAL DRAWINGS AND STRUCTURAL DRAWINGS. 3. WHERE INDICATED ON PLAN "C" INDICATES MIDSPAN CAMBER IN INCHES. 4. ALL FRAMING AND CONNECTIONS ALONG GRID LINES OR OTHERWISE INDICATED AS (SFRS) ARE PART OF THE SEISMIC FORCE RESISTING SYSTEM. TESTING AND INSPECTION OF FRAMING AND CONNECTIONS INDICATED AS SFRS SHALL MEET ALL REQUIREMENTS OF AISC 341 AND AWS D1.8. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. ALL BOLTS THAT ARE A PART OF THE SFRS ARE TO BE SLIP CRITICAL. 6. DEMAND CRITICAL WELDS ARE AS INDICATED ON PLANS, ADDITIONALLY ALL COLUMN SPLICES AND COLUMN TO BASE PLATE WELDS IN THE SFRS ARE DEMAND CRITICAL. DEMAND CRITICAL WELDS AND THE TESTING AND INSPECTION OF THEM ARE TO MEET ALL REQUIREMENTS OF AISC 341, AWS D1.1, AND AWS D1.8. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 7. SPECIAL MOMENT FRAME BEAM TO COLUMN CONNECTIONS ARE PREQUALIFIED SPECIAL WELDED UNREINFORCED FLANGE - WELDED WEB (WUF-W) CONNECTIONS. WORK, INSPECTIONS, AND TESTING IS TO MEET ALL REQUIREMENTS OF AISC 358 CHAPTERS 3, 4 AND 8, AISC 341, AND AWS D1.8. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. GENERAL NOTES AND SPECIFICATIONS INTERIOR SLAB 3 ON GRADE Fñ (PSI) CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com SHEET TITLE: 6x POSTS 6x BEAMS 4x POSTS & BEAMS 2x JOISTS, RAFTERS £ MATERIAL 2x STUDS Ä 10' HEIGHT 2x STUDS > 10' HEIGHT STRUCTURAL SPECIES AND MINIMUM GRADE, UNO DOUGLAS FIR - #1 DOUGLAS FIR - #1 DOUGLAS FIR - #1 DOUGLAS FIR - #2 DOUGLAS FIR - #2 DOUGLAS FIR - STUD DOUGLAS FIR - #2 A R C H I T E C T S 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION SAWN LUMBER MEMBER 2. EACH FRAMING MEMBER IS DESIGNATED BY A FOUR PART CODE INDICATING THE SIZE (BOTH DEPTH AND FLANGE WIDTH), STYLE, AND MATERIAL THICKNESS. FOR EXAMPLE, 600S162-54: RIM OWNER: CONCRETE SHALL BE HARD ROCK CONCRETE AND MEET THE FOLLOWING REQUIREMENTS: MIN SACKS CEMENTITIOUS MIN 28-DAY AGGREGATE MAX WATER TO MATERIAL PER 3 3 LOCATION CUBIC YARD STRENGTH (PSI) SIZE CEMENT RATIO 1. SEE PLANS, DETAILS, AND ARCHITECTURAL DRAWINGS FOR METAL FRAMING LOCATIONS. SEE ARCHITECTURAL DRAWINGS FOR WALL WIDTHS AND CONFIGURATIONS. 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 1. WOOD CONSTRUCTION (CARPENTRY) 1. EACH PIECE OF LUMBER SHALL BEAR THE STAMP OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) OR WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) SHOWING GRADE MARK OR APPROVED EQUAL. BEAMS AND POSTS TO BE FREE OF HEART CENTER (FOHC). OTHER MATERIALS SHALL BE AS SHOWN BELOW: ADDRESS: CONCRETE CONSTRUCTION LIGHT GAUGE METAL FRAMING NOTES TCCM TOWER RELOCATION STRUCTURAL SPECIFICATIONS PROJECT TITLE: H 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S0.2 SHEET NOTE; NO POWDER DRIVEN PINS AT CURB 6" 10 100 Ó" 5Ï" 1Ó" 3" 8Ó" 20 150 Í" 2Ï" 1Ï" 3" 4" 10 40 Ï" 3" 1Ó" 3" 4Ó" 10 45 Ñ" 3Ë" 1Ó" 4" 5" 10 85 Ó" 4" 1Ó" 4" 6" 20 115 4" #4 CONT SAD DS SLAB #3 8" #7 60" #10 112" NO 'PIPES' PARALLEL TO FTG THIS AREA #5 36"µ #8 76" #11 132" SLAB PER PLAN 6 AS OCCURS S1.1 CONC COVER FOR REINF STEEL @ 18"oc CONC FTG OR PAD FTG 'PIPE' IN BACKFILLED TRENCH - LOCATE ONLY ABOVE SLOPED LINE b ROUGHEN TO Ë" AMPLITUDE 8" TYPICAL INTERIOR NON-BEARING WALL AT SLAB 1" = 1'-0" LAP 2. CONTRACTOR TO VERIFY MINIMUM EDGE DISTANCES, SPACING AND THICKNESS ARE IN ACCORDANCE WITH SCHEDULE PRIOR TO INSTALLING ANCHOR. #3 Ï"ø 3" 1Ó" 3" 5" Ï"ø Ñ"ø Ó"ø Õ"ø 1"ø 1Ë"ø #4 #5 #6 #7 #8 #10 Ñ"ø Ó"ø Õ"ø 1"ø 1É"ø 1Í"ø 4" 5" 6" 7" 8" 10" 1Ó" 1Ó" 1Ó" 1Ó" 1Ó" 2Ó" 3" 3" 3" 3" 3" 6" 6Ï" 8Ë" 9Ë" 11Ï" 13" 16Ë" Í"ø #3 Ï"ø 3" 1Õ" 1Õ" 4Ë" Ï"ø #4 Ñ"ø 4" 2Ï" 2Ï" 5Ë" Ñ"ø Ó"ø #5 #6 Ó"ø 5" 3É" 3É" 6Ë" Õ"ø 6" 3Ó" 3Ó" 7Ï" Õ"ø #7 1"ø 7" 4Í" 4Í" 8" 1"ø #8 1É"ø 8" 5" 5" 10" N/A #9 1Í"ø 9" 5Ñ" 5Ñ" 11Ë" 1Ë"ø #10 1Ï"ø 10" 6Ë" 6Ë" 12Ï" ANCHOR PER PLAN & DETAILS TYP REINF LAP STD HOOK STD HOOK AT ADDL BARS STD HOOK LAP 8" MIN METAL JOINT U BAR TO MATCH HORIZ BAR OR 8 TYPICAL CORNER, INTERSECTION AND END REINFORCING db TYP SLAB ON GRADE TYP SLAB ON GRADE TYP REINF CONT THRU TYP REINF CONT THRU REINF CONT THRU OR LAP PER 1 S1.1 ROUGHEN JOINT BY SAND BLASTING TO EXPOSE AGGREGATE TO Ë" AMPLITUDE B TYPICAL REINFORCING DETAILS (f'c = 2500psi MIN) 1 3/4" = 1'-0" 1 1/2" MIN 1 1/2" MIN LOCATE VERTICAL PIPES INSIDE WALL THICKEN AT 'PIPE' AS REQD TO PROVIDE CLEARANCE TO REINF & CONC COVER TO 'PIPE'. PROVIDE #4 HORIZ AT 'PIPE'. 12" 12" B 4 SLAB ON GRADE JOINTS 'PIPE' THRU FTG IN 'PIPE' SLEEVE 3/4" = 1'-0" NOTE: LOCATION OF JOINTS TO BE SUBMITTED TO ARCHITECT/ ENGINEER FOR REVIEW PRIOR TO PLACEMENT OF CONC KEY FROM BEVELED 2x8. DO NOT LOCATE WITHIN 48" OF HOLDOWN OR COL. B SLAB PER PLAN CONTRACTOR TO VERIFY MINIMUM EDGE DISTANCES, SPACING AND THICKNESS ARE IN ACCORDANCE WITH SCHEDULE PRIOR TO INSTALLING ANCHOR. 3. A 1" MAX 1 1/2" MIN COVER FOOTING CONSTRUCTION JOINT d 3d 8" MAX DIA 48" MIN TO NEXT BUNDLE 'PIPE' THRU FTG PIPE/CONDUIT VAPOR RETARDER - SEAL AT PENETRATION, TYP COMPACTED CRUSHED BASE ROCK PER NOTE #3 d PIPE/CONDUIT REQUIRING EMBEDMENT IN CONC 5 PIPE/CONDUIT IN COMPACTED ROCK 4. SPECIAL INSPECTION IS REQUIRED PER SECTION 1705 AND THE REQUIREMENTS OF THE ICC REPORTS. THE SPECIAL INSPECTOR MUST BE ON THE JOB SITE PERIODICALLY DURING ANCHOR INSTALLATION TO VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, HOLE CLEANLINESS, EMBEDMENT DEPTH, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, DRILL BIT DIAMETER, HOLE DEPTH, EDGE DISTANCE(S), ANCHOR SPACING (S), CONCRETE THICKNESS, AND ADHESIVE INJECTION. 1 3/4" = 1'-0" PER NOTE #3 2 ADHESIVE ANCHOR IN CONCRETE ¢ 'PIPE' 1. 2. 8" MIN CONTROL JOINT #4 CONT SAD 4" MAX, 2" MAX FOR SUBGRADE TO REMAIN LEVEL 3. 4. BASE £ 5. 6. 7. 3/4" = 1'-0" SLAB BLOCKOUT 1" = 1'-0" CONT FTG PAD FTG SIMILAR NOTES: REINF PER PLAN 10 PROVIDE REINF TO MATCH FTG REINF SEE NOTE #8 8. 12 PER NOTE #3 'PIPE' CONDUIT & PIPE AT SLAB ON GRADE 24" SQ MIN OPTIONAL DIAMOND BLOCKOUT COLUMN PER PLAN LAP OPTIONAL BUNDLED 'PIPE' SLEEVE 3d 24"ø MIN SONOTUBE BLOCKOUT SLAB FOR COLUMN HOLES TO BE DRILLED WITH ROTARY DRILL ONLY. WHEN DRILLING HOLES IN EXISTING CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. MAINTAIN A REASONABLE CLEARANCE BETWEEN REINFORCEMENT AND THE DRILLED-IN ANCHOR. FILL ABANDONED HOLES WITH HIGH STRENGTH GROUT. PLAN VIEW A TYP REINF 3/4" = 1'-0" 1 1/2" DEEPEN FTG AS REQD FOR PIPE COVER & CLEARANCES TO REINF STEEL PER NOTE #3 NOTES: 2. VERT PIPE (WRAPPED) CONTROL JOINT NOTES: 1. LOCATION OF PIPE/CONDUIT BY OTHERS. 2. PROVIDE SLEEVE AT PIPE PER __________ 2 SIM. S1.1 PIPE/CONDUIT EDGE OF CONC AS OCCURS INSTALL ADHESIVE ANCHORS PER MANUFACTURER'S INFORMATION AND ICC REPORT. CROSSTIE #3, #4, #5 STIRRUP #3, #4, #5 3/4" = 1'-0" SõÙÜ 1. 6db R = 2db 135° STIRRUP TIES #3, #4, #5 SAWCUT WITHIN 8 HOURS OF CONCRETE PLACEMENT. USE JOINT SEALANT COMPOUND TO FILL CUT PERMIT SET b 6d 135° IN R = 2db FORMED JOINT PLASTIC CONTROL JOINT OR É" x1Ï" MASONITE OR Ï" x1Ï" TOOLED JOINT FILLED W/ FLEXIBLE SEALANT SPLICE db CONSTRUCTION/DOWEL JOINT 1 1/2" STD HOOK ADDL VERT AS REQD 8" MIN 6d b, 3" M Ï" SQ FLEXIBLE SEALANT KEY FROM BEVELED 2x4 Hóô CõÙÜ LAP COL BAR & STRUCT OFFSET Ï"ø x 18" SMOOTH ROD @ 18"oc JOINT CAP PLAN VIEW - SINGLE LAYER 9 TOP OF CONC 90° HOOK 4 db OR 2 1/2" MIN 1" MIN OR EMBED IN CONC Í"ø 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com R=3 db FOR #3 TO #8 R=4 db FOR #9 TO #11 2" MIN STD HOOK TYP WALL OR FOOTING REINF LAP REBAR 180° HOOK D CORNER BAR TO MATCH HORIZ BAR NOTE: FOOTING REINF AT CORNER AND INTERSECTION TO BE SIMILAR THRD ROD 1" 1Ï" WIRE TOGETHER AT EACH END PLAN VIEW - 2 OR MORE LAYERS MIN CONC DEPTH HõÙÜ NOT EXPOSED TO EARTH OR WEATHER #5 & SMALLER #6 & LARGER, & ALL BM STIRRUPS, COL TIES & SPIRALS FOR INFORMATION NOT NOTED SEE __________ 2 S1.1 D/4 LAP (2) ADDL VERTS AS REQD TYP WALL OR FOOTING REINF MIN SPACING SõÙÜ 1Ï" 2" STANDARD HOOKS & BENDS A MIN EDGE DISTANCE CõÙÜ EXPOSED TO EARTH (FORMED) OR WEATHER #5 & SMALLER #6 & LARGER 3/4" ENGINEER = 1'-0" NOTE: TRENCH LOCATION PER CBC 1809A.14 STD HOOK ADDL VERTS AS REQD CORNER BAR TO MATCH HORIZ BAR MIN EMBED UNO Hóô 3" TRENCHING ADJACENT TO FOOTING 3 NOT TO SCALE PILOT HOLE CAST AGAINST EARTH OR GRADE 1 MAX 4. THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE PERIODICALLY DURING ANCHOR INSTALLATION TO VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, HOLE CLEANLINESS, EMBEDMENT DEPTH, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, DRILL BIT DIAMETER, HOLE DEPTH, EDGE DISTANCE(S), ANCHOR SPACING(S), CONCRETE THICKNESS, AND TIGHTENING TORQUE. ADHESIVE ANCHOR IN 2500 PSI MIN CONCRETE CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 'CLR' 6 3. HOLES TO BE DRILLED WITH ROTARY DRILL ONLY. WHEN INSTALLING DRILLED-IN ANCHORS IN EXISTING REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. MAINTAIN A REASONABLE CLEARANCE BETWEEN REINFORCEMENT AND THE DRILLED-IN ANCHOR. FILL ABANDONED HOLES WITH HIGH STRENGTH GROUT. SCREW ANCHOR IN CONCRETE 12 S1.1 ALTERNATE CURB OPTION 7 A R C H I T E C T S ALL REINFORCING BARS SHALL EXTEND AS FAR AS POSSIBLE AND END IN A STANDARD 90° OR 180° HOOK UNLESS DETAILED OTHERWISE 9" #4x ADHESIVE ANCHOR @ 18"oc IN LIEU OF CIP DOWEL AT CONTRACTORS OPTION, SEE 1 DEEPEN FTG W/ LEAN CONC WHERE DEEPER TRENCH IS REQD 2" DSA/OSHPD 1. INSTALL SCREW ANCHORS PER MANUFACTURER'S INFORMATION AND ICC REPORT INSTRUCTIONS. SPECIAL INSPECTION IS REQUIRED PER SECTION 1705 OF THE CBC AND THE REQUIREMENTS OF THE ICC REPORTS. INSTALLED ANCHORS SHALL BRING CONNECTED PLIES INTO FIRM CONTACT, MEETING THE INSTALL TORQUE BUT NOT EXCEEDING THE MAXIMUM INSTALL TORQUE. RIM (CLASS B TOP BAR) BAR SPACING SHALL NOT BE LESS THAN 4x BAR DIAMETER OR 4". 2 2" MIN COVER AT ADHESIVE ANCHOR ENGINEER: 1. FIXTURE HOLE SIZE MIN É"ø OVERSIZE. 2. CALC ACTUAL CONDITION AND LOAD. 3. INTERIOR DRY USE ONLY. NOTES: HILTI HITRE 500-SD (ICC-ESR 2322) 24" PAD GRADE 4" EMBED AT ADHESIVE ANCHOR HOLE DEPTH PER MFR SõÙÜ EDGE OF CONC AS OCCURS SIMPSON AT-XP (IAPMO UES ER263) #4 2" MIN HÜÛõ CõÙÜ ANCHOR 18" MIN #4 CONT TOP OF CONC ADHESIVE TYPE 94" µ WHERE COVER NOT LESS THAN 1Ï", #5 LAP LENGTH = 30" 1 MAX 1 SLOPE ANCHOR PER PLAN & DETAILS 11 #9 6 DEPRESSED SLAB - 4" MAX 3/4" = 1'-0" TYPICAL CONCRETE DETAILS 3" 38" SHEET TITLE: 1Ó" #6 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION 4" 14" OWNER: Ñ" #3 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 50 65 LAP LENGTH ADDRESS: 10 10 SIZE TCCM TOWER RELOCATION 4" 5" LAP LENGTH PROJECT TITLE: 3" 3" SIZE 12db 1Ó" 1Ó" LAP LENGTH 9" 2Ï" 3Ë" CLR TYP HILTI KH-EZ (ICC-ESR 3027) Í" Ï" SIZE NO DEPTH RESTRICTIONS ON TRENCHES OR DEEPENING OF FOOTINGS OUTSIDE THIS ZONE 6" MIN SAD SIMPSON TITEN HD (ICC-ESR 2713) 4xb SEE TYPICAL MTL STUD DETAILS FOR TRACK ANCHORAGE 3" CLR ANCHOR TYPE MAX MINIMUM ANCHOR MINIMUM MINIMUM MINIMUM CONCRETE INSTALL INSTALL TORQUE AND PILOT EMBEDMENT EDGE DIST SPACING TORQUE DEPTH (FT-LB) HOLE DIA (FT-LB) HÜÛõ CõÙÜ SõÙÜ HõÙÜ MINIMUM BAR LAPS FOR REINFORCING STEEL CONCRETE STRENGTH: 2500 PSI OR GREATER (STAGGER SPLICES) STUD & TRACK PER SCHED db SCREW ANCHOR IN 2500 PSI MIN CONCRETE 2 'PIPE' = ANY PENETRATION THRU OR EMBEDDED IN FOUNDATION. ALL PIPES THROUGH FOOTINGS TO BE WRAPPED OR SLEEVED AS FOLLOWS: a. SLEEVES: PROVIDE 1" MIN CLEAR ALL AROUND O.D. PIPE TO I.D. SLEEVE, UNO. SEAL SLEEVE ENDS WITH MASTIC OR PLASTIC BITUMINOUS CEMENT. b. WRAPPED VERTICAL PIPES: PROVIDE É" NOMINAL SHEET FOAM WITH (3) WRAPS MINIMUM, UNO. c. WRAPPED HORIZONTAL PIPES: PROVIDE É" NOMINAL SHEET FOAM WITH (8) WRAPS MINIMUM, UNO. d. UNDERGROUND FIRE LINES 4" AND LARGER: 1. SLEEVES: PROVIDE 2" MIN CLEAR ALL AROUND O.D. PIPE TO I.D. SLEEVE. SEAL ENDS PER ABOVE. 2. WRAPPED: PROVIDE É" NOMINAL SHEET FOAM WITH (16) WRAPS MINIMUM. WRAPPED AND SLEEVED PIPES SHALL HAVE 1Ï" MIN CLEAR TO REINF STEEL. MINIMUM CONCRETE COVER AT PIPES TO BE 3". CLEARANCE BETWEEN 'PIPES' TO BE 3d MIN TYP WITH A MAXIMUM OF (8) PIPES PER 48". GROUPS OF PIPES MAY BE BUNDLED AS SHOWN, EXCEPT IN PAD FOOTINGS. NO 'PIPE' TO RUN PARALLEL IN FOOTINGS, STEM OR CURB. PVC CONDUIT ('PIPE') EMBEDDED IN CURB/STEM MAY BE WIRE TIED TO HORIZONTAL REINF. NO HORIZONTAL PIPES ALLOWED THROUGH FOOTING WITHIN 2'-0" EACH SIDE OF HOLDOWNS OR STEEL COLUMNS. NO VERTICAL PIPES ALLOWED IN FOOTINGS AT BRACED FRAMES. PROVIDE 18" MIN OF COMPACTED FILL ABOVE PIPES UP TO 12"ø, FOR LARGER PIPES INCREASE COMPACTED FILL DEPTH 1'-0" OF FOR EACH 6" INCREASE IN PIPE DIAMETER. OTHERWISE DEEPEN FOOTING AS SHOWN. PIPES THRU FOOTING 3/4" = 1'-0" NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S1.1 SHEET 10d @ 6"oc (4) 16d TO BM 2x SB ES BM 16d @ 12"oc ES 2x FLAT BLOCKING UNO HSS COLUMN AT CORNER C 4x W/ Ñ"ø THREADED STUD BOLT, CSK (1" MAX) @ 24"oc, TYP UNO Ï" MAX 2x OR 3x ES BLOCKS WHERE REQUIRED ALIGN W/ NAILER ABV 2x TRIM STUD, SAD FOR END OF WALL LOCATION SECTION AT TYPICAL NAIL SPACING SEE OTHERWISE HSS COLUMN AT END OF WALL B 4 A 2x UNO, CSK NOT PERMITTED AT 2x SEE 4x HEADER TO MATCH JOIST DEPTH UNO PEN TO MEMBER AT EDGE OF OPENING FOR 3 TIMES LENGTH OF OPENING OTHERWISE CS16 x "2W" LENGTH STRAP AT ES OF OPNG GREATER THAN 24"x24" ON TOP OF SHTG WIDE FLANGE NAILER D (EDGE OF OPNG SIM) A HGR TYP W 4'-0" MAX HSS COLUMN WITHIN WALL 1Ï" MIN PENETRATION AT 8d 1Ñ" MIN PENETRATION AT 10d INTO JOIST, STUD OR BLOCKING NOTE: SHEATHING SHEETS ARE TO BE AS LARGE AS POSSIBLE. STAGGER SHEETS. JOINTS ARE TO BE CENTERED OVER BEARING. NAIL HEADS SHALL BE DRIVEN FLUSH WITH SHEATHING. MIN SHTG SIZE IS 24" WIDTH x 48" LENGTH AT FLOOR AND ROOF, AND 12"x48" AT WALLS. 2" MIN OTHERWISE (CHANNEL & HSS SIM) A OPENING TO 4'-0" SQUARE TYPICAL STEEL BEAM/COLUMN NAILERS 3/4" = 1'-0" FRAME OPNG PER IF SCHEDULE IS MODIFIED, UPDATE THE SCHEDULE IN THE PROJECT FILE. A- STRAP PER OPNG A - PEN TO CONT FRMG FOR 2 TIMES 'L' TIE STRAP SCHEDULE STRAP CASE 1 (See Notes #1 & #2) CASE 2 EL RL MIN. END LENGTH (EL) A CS16 (10) 10d 10d @ 4"oc STGR FILL ALL NAIL HOLES 10d @ 4"oc STGR 12" B CS14 (13) 10d 10d @ 4"oc STGR FILL ALL NAIL HOLES 10d @ 4"oc STGR 16" C CMSTC16 (25) 10d 10d @ 3"oc STGR FILL ALL NAIL HOLES 10d @ 3"oc STGR 24" (33) 10d 10d @ 3Ï"oc STGR FILL ALL NAIL HOLES 10d @ 3Ï"oc STGR 32" (43) 10d 10d @ 3Ï"oc STGR FILL ALL NAIL HOLES 10d @ 3Ï"oc STGR 48" D E CMST14 CMST12 1. CASE 1 APPLIES UNLESS END LENGTH (EL) IS NOTED ON PLANS. WHERE END LENGTH (EL) IS NOTED, SEE CASE 2. CUT LENGTH EQ CUT LENGTH EQ CASE 1 END LENGTH (EL) REMAINDER LENGTH (RL) OPNG < 4'-0" 'L' B CLOSELY SPACED OPENINGS BETWEEN FRAMING 2x6 W/ A35 EE (USE 4x W/ HGRS AT MECH EQUIP ATTACHMENT) ROOF PEN AROUND OPNG 2x6 W/ A35 EE (USE 4x W/ HGRS AT MECH EQUIP ATTACHMENT) 24" MAX 3. LOCATE STRAPS OVER PLYWOOD AND BLOCK UNDER STRAP W/ FLAT 2x6 WHERE NO FRAMING OCCURS, UNO. PLAN C 4. SEE PLANS FOR STRAP LENGTHS, LOCATIONS AND DETAILS, UNO. TIE STRAP SCHEDULE 3/4" = 1'-0" ENGINEER NOTE: SIMPSON ICC REPORT VALUES BASED ON CALCULATIONS WITH GRADE 50 STEEL. NDS NAIL CAPACITY AT 14 & 16 GAUGE MATERIAL IS GOVERNED BY MODE III WHICH USES GRADE 33 STEEL. NUMBER OF NAILS REQUIRED PER SIMPSON NOT NDS IS CORRECT. 2 ROOF OR FLOOR JST DO NOT CUT 2x6 W/ A35 EE (USE 4x W/ HGRS AT MECH EQUIPMENT ATTACHMENT) CASE 2 2. AS REQUIRED, PROVIDE CLOSER NAIL SPACING TO MEET MINIMUM NAILING EACH SIDE OF . 5 OPNG 24" MAX MARK MAX. NAIL SPACING MIN. NAILING ES OF TYPICAL WOOD DETAILS A WALL PEN A 1 1/2" = 1'-0" SEE W/2 3/8" AT 2x FRAMING 3/4" AT 3x FRAMING PDP @ 24"oc SHIM AS REQD L 4'-0" MAX DBL FRMG MEMBERS ES OF OPNG WHERE FRMG IS INTERRUPTED UNO SHEET TITLE: 2x ES W/ Ñ"ø THREADED STUD BOLT @ 32"oc, TYP UNO PROVIDE 3x ES W/ Ñ"ø THREADED STUD BOLT @ 24"oc AT WALL PEN LESS THAN 6"oc Ê PERMIT SET 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION HSS COLUMN PER PLAN AT 3x MEMBER SHEATHING NAILING 4x ES W/ Ñ"ø THREADED STUD BOLT @ 24"oc, TYP UNO - PROVIDE Ñ"ø THREADED STUD BOLT @ 12"oc AT WALL PEN LESS THAN 4"oc W/2 MB MAY BE USED IN LIEU OF THREADED STUD BOLT G NOTE: PROVIDE BOLTS 4Ï" MIN & 12" MAX FROM EE OF ALL NAILERS TYP 3/4" = 1'-0" WALL SHTG ES AS OCCURS (3"oc OR LESS SPACING AT FLOOR OR ROOF) (4"oc OR LESS SPACING AT SHEARWALL) 7 1 3/4" = 1'-0" OWNER: TYPICAL BEAM IN AND THRU STUD WALL HOLES AND NOTCHES IN WOOD STUDS, JOISTS, BEAMS AND PLATES 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 CUT TO BEAR NOTE: DO NOT NOTCH OR DRILL STUDS AND JOISTS WITHIN D' OR D OF KNOTS IN WOOD D' POST TO MATCH BM WIDTH AND WALL THICKNESS TYP PLAN VIEW AT CLOSE NAIL SPACING É" GAP D'/3 MAX ADDRESS: BM PER PLAN 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com D = DEPTH OF JOIST OR BEAM D' = STUD OR PLATE WIDTH L = CLEAR SPAN TYP STUD ES TCCM TOWER RELOCATION A35 ES ¢ MEMBER AND HOLE PROJECT TITLE: TYP DBL TOP PLATES 3/8" 1/2" AT 4x MEMBER END 4'-0" MIN FROM HOLE TO TOP £ SPLICE O PE NI N 1/2" 3/4" ST2122 - CENTER ON HOLES AND ON DOUBLE £ 16d @ 12"oc ES POST TO MATCH BM WIDTH AND WALL THICKNESS TYP INTERIOR CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com D/5 & 2" MAX EPC PANEL JOINT A R C H I T E C T S BEAM TYP STUDS RIM JOIST OR BEAM D/4 MAX D LAP STUDS TO BM (4) 16d TO BM JST OR BM NAIL SPACING D MIN A35 A35 3 3/4" = 1'-0" 3D MAX D MIN 'W' NAILING SCHEDULE L/3 MIN L/2 MAX D/4 (2) 10d (2) 10d (2) 10d OR (2) 16d (2) 8d (2) 16d 16d @ 16"oc BRIDGING TO JOIST, TOE NAIL EACH END 2" SUBFLOOR TO JOIST OR GIRDER, BLIND & FACE NAIL SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS (3) 16d @ 16"oc TOP PLATE TO STUD, END NAIL (2) 16d STUD TO SOLE PLATE, TOE NAIL (4) 8d DOUBLE STUDS AT EXTERIOR WALLS, FACE NAIL 16d @ 12"oc DOUBLE STUDS, FACE NAIL 16d @ 24"oc DOUBLE TOP PLATES, FACE NAIL 16d @ 12"oc TOP PLATES, LAPS & INTERSECTIONS, FACE NAIL (3) 16d CONTINUOUS HEADER, TWO PIECES 16d @ 16"oc ALONG EACH EDGE DOUBLE TOP PLATE LAP AT CORNER (3) 16d CONTINUOUS HEADER TO STUD, TOE NAIL (4) 8d CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL (3) 16d CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL (3) 16d BUILT-UP CORNER STUDS 16d @ 12"oc RIBBONS TO STUDS: ONE (1) INCH RIBBONS (3) 8d TWO (2) INCH RIBBONS (3) 16d CEILING STRIPPING (2x MIN) 16d AT 45 SLANT, 16d AT 90° TO SUPPORTS 6 LTP4 DBL TOP £ 2" MIN (3) 16d (1) 16d D/6 MAX TOP £ SPLICE STRAP PER SCHEDULE (2) 10d D' MIN RIM JOIST TO TOP £, TOE NAIL TRUSSES, JOISTS OR RAFTERS AT ALL BEARING POINTS TOE NAILS EACH SIDE TRUSSES, JOISTS OR RAFTERS TO SIDE OF STUDS EIGHT (8) INCH JOISTS OR LESS FOR EACH ADDITIONAL 4 INCHES OF DEPTH OF JOIST BLOCKING BETWEEN JOISTS OR RAFTERS: TO JOIST OR RAFTERS - TOE NAILS EA SIDE, EA END TO JOIST OR RAFTER BEARINGS - TOE NAILS EA SIDE BLOCKING BETWEEN STUDS, EACH END TOE NAILS LOCATE OPNG BETWEEN FRMG, NO ADDL OPNGS WITHIN 4'-0" ALL AROUND, WHEN CLOSER OPNGS OCCUR SEE ISOLATED OPENING BETWEEN FRAMING UP TO 24" B NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC OPENING IN DIAPHRAGM 3/4" = 1'-0" DWG NO: S1.2 SHEET #10 SMS @ 6"oc, TYP 54 MILS x 2"x4" £ W/ (4) #8 SMS @ 24"oc ES EXTEND £ & ADD (2) #8 SMS EA STUD AT MULTIPLE STUD CONNECTION É (2) PDP @ 16"oc, (2) ES AT JAMBS OR OPTIONAL WELD 3" 1Ï-16 TYP 1-12 OR 1Ï-18 INTERUPT TRACK TO PASS JAMB CLIPS VERTI CLIP SL600 JAMB CLIP AT OPENINGS OVER 6'-0" WIDE, PROVIDE CLIP ES AT OPENINGS OVER 9'-0" WIDE, SHOOT TO STEEL BM W/ (4) PDP TYP 8 SEE OTHERWISE S1.3 __________ 58-05-24 B STUD STUDS £ 2"x4"x54 MIL W/ (4) #8 SMS @ 24"oc ES TRACK #8 SMS @ 6"oc (TYP 4 PLACES) ALTERNATE CONNECTION (PLAN VIEW) HEADERS B A R C H I T E C T S SEE 8 S7.2 b Ä 10'-0" SEE 3A S1.3 b Ä 16'-0" SEE 3B S1.3 800S162-68 19'-0" 16"oc 1000S162-43 (ABV) 19'-0" 16"oc 600S162-43 12'-0" 16"oc AT TOWER: (2) 800S162-54 STUDS AND (2) 600T150-54 TRACKS AT FACADE: (2) 800S162-54 STUDS AND (2) 1000T150-54 TRACKS CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com EXTERIOR HEADERS EXTERIOR SILLS WELDED CONNECTION (PLAN VIEW) A TRACK T&B RIM REFERENCE DETAIL AT TOWER: HEADERS A MAX MAX SPAN/LENGTH SPACING UNO MINIMUM MEMBER SIZE AT FACADE: #8 SMS @ 6"oc (TYP 4 PLACES) C OPTION 2 WELDS ES JAMB LOCATION EXTERIOR STUDS TRACK THICKNESS TO MATCH JAMB STUDS (4" MAX DEPTH) DEFLECTION TRACK 1 __________ NOTE: SEE SCHEDULE S1.3 FOR REQD TRACK AND STUD SIZES. STUDS JAMB STUDS PER SCHEDULE BM PER PLAN LIGHT GAUGE FRAMING SCHEDULE TRACK T&B EXTERIOR JAMBS SILLS C 600S162-43 STUD AND 600T150-43 TRACK b Ä 8'-0" (2) 800S162-68 19'-0" (2) 600S162-97 12'-0" SEE 3C S1.3 SEE 6 S1.3 SEE 3 S1.3 b Ä 15'-0" b Ä 8'-0" 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com AT TOWER: 1ENGINEER 1/2" = 1'-0" NOTE: A35 W/ #6 WS TO SHTG 3/4" GAP 1Ï" PERPENDICULAR TO JOISTS É 54 MILS MIN SLOTTED SLIP TRACK W/ ALLOWANCE FOR Ó" DEFLECTION. INSTALL PER MFR & ICC ES REPORT É 1 3B S1.3 T&B SILL PER SCHEDULE b Ä 12'-0" SEE 3 S1.3 INTERIOR SILLS 600S162-43 STUD AND 600T150-43 TRACK b Ä 12'-0" SEE 3 S1.3 INTERIOR JAMBS (2) 600S162-43 16'-0" SEE 6 S1.3 1. 2. CUT & BEND AS SHOWN T&B 3. 4. B A WELDED CONNECTION B 5. 6. 7. ALTERNATE CONNECTION (2) 16d EE 54 MILS DEFLECTION TRACK PER 7 S1.3 (2) 600S162-43 STUDS AND (2) 600T150-43 TRACKS #8 SMS ES TYP STUDS PER ELEV OR DETAILS (INTERIOR WALLS ONLY) 2x BLKG @ 24"oc W/ A35 EE INTERIOR HEADERS (3) #8 SMS TYP ES T&B STUDS PER ELEV OR DETAILS OPTION A NOTES FOR ALL OPTIONS: 1. WALL COVERING SHALL NOT SCREW TO TOP TRACK. 2. WHERE SHTG DOES NOT EXTEND TO STRUCTURE/ 1 58-00-02 TOP OF WALL, PROVIDE __________ S1.4 STRAP AND BLKG PER AT UNSHEATHED FACE AT 4'-0"oc MAX. OPTION 8. NON-BEARING WALL DEFLECTION TRACK AT TOP 7 TYPICAL SILL CONNECTION 4 1" = 1'-0" 1 1" =ENGINEER 1'-0" NOTE: ENGINEER NOTE: MODIFY SLIPTRACK, DEFLECTION TRACK ETC AS DESIRED MUST USE THIS IN CONJUNCTION OF OTHER DETAILS SHOWING CONNECTION OF TOP TRACK TO STRUCTURE MUST PROVIDE CALC FOR OUT OF PLANE LOADS AT TOP TRACK #12x2" WS EA BLK 16"oc JAMB STUDS PER SCHEDULE __________ 1" MIN 16'-0" b Ä 12'-0" TYPICAL TRACK TO BE SAME GAUGE AS STUD OR 43 MILS MIN, UNO. FLANGE TO BE 1Ï" MIN. AT EXTERIOR WALL WITH BUMPOUT BOTH MAIN WALL & FURRING WALL ARE EXTERIOR STUDS. PROVIDE BRIDGING @ 4'-0"oc MAX PER 1/S1.4 AT BOTH WALLS. A WALL WITH ANY PORTION HAVING EXTERIOR EXPOSURE SHALL BE FRAMED ENTIRELY AS AN EXTERIOR WALL. MULTIPLE ADJACENT WINDOWS TO EACH HAVE INDIVIDUAL HEADERS AND FULL JAMB STUDS BETWEEN WINDOWS. TYPICAL WALL BRIDGING/BLOCKING PER 1/S1.4 . TYPICAL STUD/JOIST TO TRACK PER 2/S1.4. COORDINATE STUD DEPTH W/ ARCH DRAWINGS. INCREASE MIN HDR, SILL OR JAMB MEMBER DEPTHS AS REQD TO MATCH ACTUAL WALL STUD DEPTH. "b" INDICATES OPENING WIDTH PER 2/S1.3. SCHEDULE - LIGHT GAUGE METAL FRAMING, UNO 3/4" = 1'-0" REMOVE FLAT £ FROM B AT EXTERIOR APPLICATIONS. PARALLEL TO JOISTS TOP OF METAL STUD WALL AT EXISTING WOOD JOISTS 1" MAX 3/4" = 1'-0" OPTION 1-24 É STL BM PER PLAN DEFLECTION 7 TRACK PER __________ S1.3 PROJECT TITLE: BEND AT TRACK WEB 58-00-06 (2) PDP @ 16"oc OR OPTIONAL WELD A 54 MILS £ 3" x HEADER HT ES W/ (3) #8 SMS TO JAMB & HDR (OMIT AT TRACK & FLAT STUD HEADER) WALL AT BEAM 4" MAX 2"xÑ"x54 MILS COLD ROLLED @ 16"oc OR L1Ï"x1Ï"x TRACK GAUGE OR 54 MILS MIN x (STUD WIDTH Ï") W/ (3) #8 SMS EA LEG T&B STL BM PER PLAN DBL ATTACHMENTS AT ROOF OR FLOOR AT JAMB 2" 1Ï" x 54 1Ï" MILS Z @ 16"oc W/ (2) PDP B É DEFLECTION 7 TRACK PER __________ S1.3 B ALTERNATE SCREWED CONNECTION (2) #10 SMS 58-00-36 CUT FLANGE ES & EXTEND WEB TO OVERLAP W/ JAMB W/ (3) #8 SMS ES WALL OFFSET AT BEAM FIREPROOFING, SAD HEADER PER SCHEDULE DEFLECTION TRACK PER __________ 7 S1.3 É 4 5 S1.3 58-00-24 58-01-20 STUDS, JAMBS, & MULLIONS PER SCHED__________ 1 S1.3 __________ TYP ES (T&B AT É 1 TRACK & FLAT STUD HDR) 58-00-00 "b" STL BM PER PLAN x 54 1Ï" MILS Z @ 16"oc W/ (2) PDP 3A S1.3 __________ 2 WELDS É ES TYP TRACK PER __________ 1 58-01-01A S1.3 2-10 (3) #8 SMS TYP (2) #10 SMS ATTACHMENT OF NON-BEARING STUDS TO STEEL BEAM É CUT & BEND TRACK AS SHOWN TRIMMER WHERE OCCURS 58-00-06 WALL AT BEAM WITH FIREPROOFING 1" = 1'-0" 6 S1.3 #8 SMS TO EA STUD TYP 3 AT SILL S1.3 __________ 1Ï" 8 58-01-04 4 JAMB STUDS PER SCHEDULE 58-00-06 2"xÑ"x54 MILS COLD ROLLED @ 16"oc OR C 3 AT HDR S1.3 __________ 58-01-20 2" 10 PERMIT SET TYPICAL METAL STUD ELEVATION AND CONNECTION DETAILS #12x2" WS EA JST 600S162-43 SHEET TITLE: "T200" TRACK TO MATCH SIZE & THICKNESS OF TYP STUDS, UNO W/ #8 SMS ES TO EA STUD OR JAMB PIECE IN BOTTOM Ï" OF TRACK INTERIOR STUDS 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION (E) JST 54 MILS DEFLECTION TRACK PER 7 S1.3 AT FACADE: 1000T150-68 TRACK OWNER: 10 S1.3 (E) JST 1" 1/2" PARAPET SILLS TOP TRACK "T150" TO MATCH STUDS, 54 MILS MIN AT INTERIOR STUDS, 68 MILS MIN AT EXTERIOR STUDS, UNO. NO ATTACHMENT TO TRACK BLW 3/4" GAP ATTACHMENT TO STRUCTURE PER #12x2" WS EA JST BENT 68 MILS DEFLECTION TRACK - SNUG FIT TO WALL TRACK 1 1/2" = 1'-0" 1. ONLY USE ALTERNATE B AT INTERIOR LIGHTLY LOADED CONDITIONS. 2. OPTION C IS PER 2010 OSHPD STANDARD PARTITION WALL DETAIL PACKAGE. 600S162-43 STUD AND 600T150-43 TRACK 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 ENGINEER TO CHECK BEAM'S BOTTOM FLANGE STABILITY TYPICAL NON-BEARING HEADER AND SILLS 3 ADDRESS: 1" = 1'-0" TYPICAL MULTIPLE STUD CONNECTION 6 TCCM TOWER RELOCATION ATTACHMENT OF JAMB STUDS TO STEEL BEAM 9 A 5 SCREWED CONNECTION TYPICAL HEADER CONNECTION 1" = 1'-0" TYP T&B 58-01-04 58-01-20 NOTE #1 SEE 7 58-00-12 S1.1 FOR CONN TO CONC C WELDED CONNECTION NO DESCRIPTION 1 BRIDGING PER __________ S1.4 58-00-02 4 S1.3 9 S1.4 58-00-23 58-01-20 58-01-23B 58-01-24 DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: 2 NON-BEARING WALL (OPENING AS OCCURS) 1" = 1'-0" S1.3 SHEET ¢ HSS, BASE £ & AB A R C H I T E C T S 1 1/2" 1/2" 1 1/2" Ñ"ø x 6" SCREW ANCHOR PER 11 UNO S1.1 1 1/2" MAX 1 1/2" AT CORNER 30-01-03 EQ EQ MIN BEAM PER PLAN (1) #8 SMS AT EA INTERMEDIATE STUD BLOCKING: PIECE OF TRACK OR STUD SAME GAUGE AS STUD W/ WEB BENT AND ATTACHED TO STUDS W/ (2) #8 SMS TO EA FLANGE ¢ 1/2" 1 1/2" 1 1/2" Í" £ RIM ¢ 1/2" TYP 33 MILS x 2" CONT STRAP OR 1Ï" CHANNEL WHERE NO SHTG OCCURS. CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com (4) #8 SMS PER BLK B WINDOW WINDOW ABOVE A #12 SMS ES EA VERT CONT TRACK (68 MILS MIN) 162S125-33 MIN STUDS @ 16"oc AT BEAM DEPTH Å 14" AS REQD FOR FINISH ATTACHMENT, BOTH SIDES AS OCCURS #8 SMS TYP BLOCKING TO OCCUR AT EA END OF WALL OR ADJACENT TO EACH OPENING AND AT 8'-0"oc HORIZ MAX BETWEEN 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com (4) #8 SMS PER BLK GYP BD ATTACHED PER IBC (NO STRP REQD AT GYP BD) MTL STUD WALL BACKING PLATE 3 NOTE: COORDINATE W/ EXPANSION JOINT LOCATION IN FINISHES. 1ENGINEER 1/2" = 1'-0" 1"ENGINEER = 1'-0" NOTE: WALL BLOCKING FOR LIGHT LOADS. BOTH SIDES TYP EA STUD SEE OPTIONAL ATTACHMENTS BLW É PERMIT SET 1Ï"x 54 MILS CHANNEL A ENGR: PROVIDE ANCHORAGE TO FOUNDATION TO RESIST OVERTURNING OF THE WALL FOR INFORMATION 58-00-12 NOT NOTED SEE 7 S1.1 L2x2x97 MILS x 3" HORIZONTAL BRACING 6 S1.3 __________ JAMB STUDS PER SCHED (3) #8 SMS Í"ø x 4" SCREW AB PER 11 TRACK S1.1 #8 SMS EA SIDE TYPICAL SECTION AT PARTIAL HEIGHT WALL 1Ï"x1Ï" x 54 MILS CLIP ANGLE Ë" LESS THAN STUD WIDTH W/ (4) #8 SMS #8 SMS ES TRACK 1" ENGINEER = 1'-0" NOTE: PROVIDE CALCS FOR ANCHORAGE AND BASE £. 4" FOR INFORMATION NOT NOTED SEE __________ 2 S1.3 PDP " Ï 2 1/2" " Ï 2 1/2" B AT DOOR > 4'-0" WIDE C PUNCH-OUT TAB BENT DOWN W/ (2) #8 SMS " Ï PDP ES JAMB TYPICAL É (2) STUDS PER SCHED L2x2x12ga x 6" 6 S1.3 __________ L2x2x12ga x 3" CLIP ES #8 SMS EA SIDE (4) #8 SMS 6 S1.3 __________ (3) #8 SMS TRACK 4" A 9 OPENINGS B AT DOORS A 4 1" = 1'-0" EDGE OF WALL AS OCCURS TRACK OR STUD W/ PDP @ 16"oc OR ALTERNATE WELD HSS É FOR INFORMATION NOT NOTED SEE 1 S1.3 AT DOOR < 4'-0" WIDE 58-01-12 58-01-02 INTERIOR BOXED STUD BASE 1 ENGINEER 1" = 1'-0"NOTE: 1. USE FOR DSA. 2. NEED TO PROVIDE PDP COUNT. 1-16 TYP, ALTERNATE d d a = 0.7d MAX BOX HEADER CONN TO STEEL FRAMING TYP TRACK STUD OR TRACK 2" LARGER THAN WALL STUDS TYP #12 SMS @ 1Ï"oc (3) MIN AT 6" HDR (4) MIN AT 8" HDR (6) #12 SELF DRILLING SCREWS TO STL COL TYP TYP STUD OR TRACK 7 a SMOOTH CUT, r = a/2 É BOTH Ó SIDES IF PUNCH-OUT OCCURS AT RUNNER - PROVIDE 1"x1Ï" END STIFFENER TO MATCH STUD GAUGE BOTH SIDES 4" MAX Ó WELD ATTACHMENT 2.67a MAX OR 6" WHICHEVER IS SMALLER STUD SPAN/3 MIN ACTUAL SHAPE OF PUNCHOUT MAY VARY; NOT TO EXCEED MAXIMUM DIMENSIONS TYP STUD 10" MIN #8 SMS AT 32"oc STUDS TO STUD MTL STUD BOX BM A d/2 OR 2" MAX WHICHEVER IS SMALLER TYP TRACK 54 MILS ANGLE 3"x3"x4" LONG W/ (4) #12 SMS TO BOX BM AND (3) #12 SELF DRILLING SCREWS TO STL COL TYP MTL STUD BOX BM WHERE OCCURS 24" oc MIN TYP STUD OR TRACK TYP STUD W OR HSS COL PER PLAN 1" = 1'-0" AT CONC WALL #8 SMS AT 32"oc STUDS TO STUD 1 WALL BRIDGING/BLOCKING 10 " PU MIN N C TO HOU FIRS TT T YP PDP @ 16"oc AT HSS COL OR BRACE 1" = 1'-0" NOTES: 1. BRIDGING MAY BE PER OPTION 1 OR 2. 2. PROVIDE BRIDGING @ 4'-0"oc. 3. BRIDGING IS NOT REQUIRED WHERE PROPERLY ATTACHED SHEATHING OCCURS ON BOTH SIDES OF STUDS. 4. THE MAX STUD DEPTH FOR OPTION 1 IS 8" MAX. 5. PROVIDE BLOCKING PER OPTION 2 AT LOCATIONS INDICATED ON DRAWINGS OR OTHER DETAILS PDP 3" MIN TO EDGE OF WALL 10 OPTIONAL ATTACHMENT B USE AT ALL DOORS TYP EXTERIOR BOXED STUD BASE MTL STUD TRACK, MATCH THICKNESS OF BOX BM 54 MILS MIN É OPTION 1 TRACK (2) Ï"ø SCREW ANCHORS, (1) ES ALT CONN OPTIONAL ATTACHMENT A #8 SMS ES (2) Ï"ø SCREW ANCHOR @ 3" #8 SMS EA SIDE TRACK JAMB STUD PER SCHED Ó ALT CONN TO SIDE Ó OF TAB PROJECT TITLE: 8 JAMB STUDS PER SCHED 6 S1.3 __________ #8 SMS ES (2) #8 SMS 10 " PU MIN N C TO HOU FIRS TT T YP REPAIR AT PUNCH-OUT TYPICAL STUD/TRACK PUNCHOUT TYPICAL CORNERS AND INTERSECTIONS 1"ENGINEER = 1'-0" NOTE: 1. PDP PER LIGHT METAL FRAMING NOTES. 2. PROVIDE DETAIL (54-08-02) SHOWING DO NOT CONNECT AREAS AT SMF AND SCBF. SPECIAL STUD PUNCHOUT USE ONLY IF REQUIRED; USE ONLY AT NONBEARING WALLS UNDER 15'-0" TALL 5 TYPICAL STUD PUNCHOUT USE ONLY WHEN NECESSARY MAINLY FOR CA. 1" =CALCS. 1'-0"FOR SPECIAL PUNCHOUT NEED 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS #8 SMS ES FOR INFORMATION NOT NOTED SEE 1 S1.3 TYPICAL METAL STUD SOFFIT & MISCELLANEOUS DETAILS Ê INFILL AT STEEL BEAM SHEET TITLE: 6 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION TOP OF SLAB OWNER: . OPTION 2 TRACK CONT CUT TO ALLOW HSS TO PASS B 24" INCREASE STUD WIDTH AS REQD 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 #3 PDP @ 24"oc TYP TRACK TO STL BEAM ADDRESS: HSS4x4xË @ 6'-0"oc MAX UNO ON PLAN OR ELEVATION 600T150-43 TRACK OR 600S162-43 STUD W/ (2) #8 SMS AT EA STUD NOTCH FLANGES OF TRACK AT EACH STUD TCCM TOWER RELOCATION STUD (68 MILS MIN) ES W/ (4) #12 SMS TO HSS NOTE: STUDS TO HAVE FULL BEARING ON TRACK TYP SCREW ATTACHMENT 2 DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC STUD OR JOIST TO TRACK 1" = 1'-0" METAL STUD DETAILS TO BE UPDATED ONCE FAMILIES ARE CREATED FOR REVIT. 01/04/2010 DWG NO: S1.4 SHEET RIM A R C H I T E C T S FOUNDATION PLAN NOTES: 1. REFER TO SHEETS S0.1, S0.2, S1.1, S1.2, S1.3, S1.4 AND S4.1 FOR STANDARD NOTES AND DETAILS. 2. LEGEND: CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com INDICATES CONCRETE WALL. INDICATES METAL STUD WALL. INDICATES (E) FRAMING. , INDICATES HSS COLUMN. 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com INDICATES WF COLUMN. DS INDICATES DEPRESSED SLAB, SAD AND SPD FOR COMPLETE LOCATIONS, DEPTH AND SLOPE INFORMATION. INDICATES (E) FOUNDATION OR PAD. 17 INDICATES FOUNDATION OR PAD. 88 INDICATES GRIDLINE AT FOS. 88 INDICATES GRIDLINE AT ¢ OF COLUMN. INDICATES SLAB STEP, SAD. HSS8x8xÑ 1 G 5 S4.1 __________ W4 2 S4.2 HSS12x8xÌ 5" TOPPING SLAB W/ #4@18" EW AT MID DEPTH O/ 4" GRAVEL O/ 18" CONC MAT SLAB W/ #5 @ 10"oc EW 1 AT TOP AND BOT 8 __________ TYP S4.1 1'-0" 18 1 18" THICK FTG 6x6 1 S4.1 2'-4" W3 HSS12x8xÌ (E) W12x26 COLUMN TO BE REMOVED 2 S4.1 6 S4.1 1 OH S4.2 SIM W18x106 3 S4.1 5. ALL BUILDING ELEMENTS ARE NEW UNLESS PREFIXED WITH (E) 6. SEE DETAILS FOR CURB LOCATIONS. COORDINATE WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 7. PLUMBING AND ELECTRICAL CONDUIT AND GROUND STRAP SHALL NOT BE LAID WITHIN FOUNDATIONS. ALL PLUMBING AND CONDUITS THROUGH FOUNDATIONS SHALL BE PER STANDARD DETAILS. NO UTILITY PIPES OR CONDUITS SHALL BE LOCATED THRU COLUMN FOOTINGS OR FRAME FOOTINGS. NO PIPES OR CONDUITS THRU SILL PLATES SHALL BE WITHIN 12" OF HOLDOWN BOLTS. NO MECHANICAL, ELECTRICAL, OR PLUMBING OPENINGS SHALL BE LOCATED IN SHEAR WALLS UNLESS SHOWN AND DETAILED ON THE STRUCTURAL DRAWINGS. NO VERTICAL OR HORIZONTAL PIPES OR CONDUITS SHALL BE LOCATED THROUGH STEEL FRAMES, STEEL COLUMNS, OR STEEL BASE PLATES. PROVIDE FURRING AND/OR THICKENED CONCRETE WHERE REQUIRED TO CLEAR UTILITY SYSTEMS. NOTIFY STRUCTURAL ENGINEER/ARCHITECT PRIOR TO ANY INSTALLATION NOT CONFORMING TO THESE DETAILS. 8. ELEVATION OF THE TOP OF FINISHED SLAB = 0'-0", UNO 9. SEISMIC GAPS WHERE NOTED ARE DIMENSIONED CLEAR BETWEEN WALL FINISHES. THIS GAP TO BE MAINTAINED ENTIRELY CLEAR TO ALLOW FOR DIFFERENTIAL BUILDING MOVEMENT. NO PIPES, CONDUITS, ETC SHALL BE LOCATED WITHIN THE GAP. PROVIDE FLEXIBLE COUPLINGS AT ALL UTILITIES CROSSING SEISMIC GAPS. PORTION OF (E) CONC SOG TO BE REMOVED (E) FTG TO REMAIN (E) W12x26 G4 __________ HSS12x8xÌ 3 S4.1 W18x106 __________ 1 S4.2 HSS12x8xÌ HSS12x8xÌ HSS12x8xÌ 10'-3 7/8" VIF 1 S4.1 4" W18x106 _8 S7 ______ .2 __ __ HSS12x8xÌ 1 S4.1 7 1/8" VIF 4'-6" VIF W18x106 3" VIF W2 DIMENSIONS RELATED TO EXISTING CONDITIONS WHERE PROVIDED ARE FOR GENERAL REFERENCE ONLY. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. W1 (E) TS COL TO BE REMOVED 3'-4 1/4" VIF G4.9 HSS12x8xÌ 2 S3.1 ___________ 7 S4.1 4 S4.1 G5 4" 1 ___________ S3.1 18 X6 17b HSS12x8xÌ U X FOUNDATION PLAN HSS8x8xÑ 4. SHEET TITLE: 1 COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 6" VIF G3 1'-5" VIF SEISMIC GAP ABOVE F4 3. 1'-4" V DENOTES FRAME ELEVATION. 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION 1 S3.1 (E) WOOD STUD WALL PERMIT SET OWNER: 19a 19 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 20 ADDRESS: 21 TCCM TOWER RELOCATION 22 PROJECT TITLE: 22A (E) TS COL TO BE REMOVED (E) 24" CONC MAT FTG TO REMAIN 1 19 18d 18c 18a PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE 17a REVISIONS FOUNDATION PLAN 1/8" = 1'-0" PLAN NORTH DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S2.1 SHEET W1 19 4x8 TYPICAL AT PANEL JOINTS DASHED LINE INDICATES PANEL EDGE NAILING (E) 2x8 3x8 E 10'-0" (E) W14x22 RIM 18d 18c A R C H I T E C T S (E) W21x50 4x8 SB - TYP CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com (E) 2x8 (E) W14x22 3x8 W12x30 E 10'-0" 4'-4" (E) 2x6 - TYP 2x6 W12x30 2x6 2x6 W12x30 FRAMING PLAN NOTES: 4 S6.1 REFER TO SHEETS S0.1, S0.2, S1.1, S1.2, S1.3, S1.4, S5.1, S5.2, S7.1 AND S7.2 FOR STANDARD NOTES AND DETAILS. 2. LEGEND: INDICATES METAL STUD WALL. (E) W14x22 5'-8" É" TYP INDICATES (E) FRAMING. G5 INDICATES â" STRUC-1 WOOD STRUCTURAL PANEL SHEATHING W/ (3) ROWS 10d @ 2Ï" ALL PANEL EDGES AND WHERE NOTED ON PLAN 3 S6.1 3'-0" 3'-0" 2 S3.1 88 INDICATES GRIDLINE AT FACE OF STUD (FOS). 88 INDICATES GRIDLINE AT ¢ OF COLUMN. , PLAN NORTH ___________ 2 1. 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com INDICATES HSS COLUMN. INDICATES WF COLUMN. PARTIAL ENLARGED ROOF FRAMING PLAN INDICATES NON-FRAME MOMENT RESISTING CONNECTION. 3/8" = 1'-0" INDICATES FRAME MOMENT RESISTING CONNECTION. SAD HD19 TO STEEL BEAM - FIELD DRILL HOLES AT CONTRACTORS OPTION 4x12 SHORE, REMOVE AND REPLACE (E) FRAMING AS REQD TO INSTALL (N) BMS. COORD/VERIFY CONFLICTS W/ (E) MEP SYSTEMS 1 S3.1 (E) SOLID BLOCKING - TYP G 8 S7 . TY 2 P 6 SIM S6.1 W10x68 (E) W12x26 W12x30 3'-0" 4x12 SB - ALIGN W/ WALL ABV - TYP 3'-0" 1 S6.1 (E) 2x6 @ 16" 6 S6.1 __________ 5 S6.1 __________ W1 @ (E) 2x8 16" 3 S3.1 ABV 1 S3.1 BLW G5 (E) 2x8 @ 16" 5. ALL BUILDING ELEMENTS ARE NEW UNLESS PREFIXED WITH (E) 6. MECHANICAL, ELECTRICAL AND PLUMBING PENETRATIONS THROUGH WALLS, ROOFS OR FLOORS SHALL BE PER 2/S1.2. UNLESS SHOWN AND DETAILED ON THE STRUCTURAL PLANS. NOTIFY ARCHITECT/ENGINEER PRIOR TO ANY INSTALLATION NOT CONFORMING TO THESE DETAILS. 7. FIRE PROTECTION SYSTEM SUPPORTS TO BE LOCATED TO MAINTAIN A MAXIMUM OF (2) 500 LB MAX POINT LOADS WITH 15'-0" MINIMUM SEPARATION TO ANY STEEL BEAM. NO SUPPORTS TO BE HUNG FROM ROOF PLY. 8. SAD FOR EDGE OF SLAB, FO WALL, ETC. 9. SAD FOR TO SLAB OR TO STEEL ELEVATION. 10. EXISTING TO STEEL, TO FRAMING, ETC IS UNKNOWN AND SHALL BE VERIFIED PRIOR TO ANY FABRICATION. 2 S3.1 ___________ 11. BEAM CENTERLINES TO ALIGN WITH COLUMN CENTERLINES, UNO. U X (E) CONC FILL OVER METAL DECK TO BE REMOVED 12. BEAMS TO BE EQUALLY SPACED IN EACH BAY, UNO. H1 13. CONDUIT OR PLUMBING NOT ALLOWED WITHIN CONC FILL ON METAL DECK. (E) TS COLS & BRACES TO BE REMOVED 19 DIMENSIONS RELATED TO EXISTING CONDITIONS WHERE PROVIDED ARE FOR GENERAL REFERENCE ONLY. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. (E) W14x22 X6 W21x62 4. G4 W10x68 ___________ G3.5 INDICATES TIE STRAP. SEE SCHEDULE FOR STRAP, NAILING AND LENGTH COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES. (E) W14x22 (E) W14x22 ___________ __________ (E) TS BMS TO BE REMOVED, TYP 4'-6" 0" PERMIT SET DENOTES FRAME ELEVATION. 3. (E) W12x26 2 S2.2 (E) W1 4x22 (E) W16x26 W27x94 W12x30 4 S3.1 ___________ W12x30 16" 2 W2 __ __ __ _ 2x12 @ 16" MAX - TYP __________ C 20'-0" B 7 S7.1 W21x62 16" 4x12 __________ (E) W12x26 (E) W14x22 __ __ 8 S5.2 __________ 6 2x2 W1 (E) 1 S6.1 __________ W8x31 (E) W14x22 2 x2 14 W (E) 2 x8 @ (E) 2x8 @ (E) 2x8 @ ) (E C 20'-0" (E) W21x50 16" W10x68 (E) W14x22 (E )W 14 x2 9 S7.2 __________ 4x12 4x12 E 10'-0" W12x30 W10x68 (E) W18x40 C 20'-0" W27x94 C 20'-0" __________ W3 C 20'-0" (E) W16x31 16" 1 S6.1 (E) 2x1 4@ TYP U 16" NO 8@ (E) 2x 2 14x2 (E) W 2 S6.1 (E) W14x22 W4 ? INDICATES BEAMS SIZE, () NUMBER OF WELDED STUDS AND UPWARD CAMBER. PROVIDE STUDS @ 24"OC MAX SPACING AT ALL BEAMS SUPPORTING CONC FILL OVER METAL DECK, UNO. ADD STUDS AS REQUIRED. (NS) INDICATES NO STUDS. WHERE NO CAMBER IS SPECIFIED FABRICATE BEAM WITH NATURAL CAMBER UP. 18d 18c ROOF FRAMING PLAN 1 (E) CONC WALL 1Ë"ø THREADED ROD C 20'-0" G3 W16x26 (12) C=1" W4 4x8 INDICATES SFRS COLLECTOR CONNECTION, PROVIDE DOUBLE ROW OF BOLTS AT CONNECTION PER STANDARD DETAILS. 16 SHEET TITLE: SEISMIC GAP 17 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION HD19 TO (E) CONCRETE WALL FIELD DRILL HOLES IN (E) CONCRETE WALL - SCAN WALL FOR REINF PRIOR TO DRILLING (E) 6" WOOD STUD WALL BELOW V 17b OWNER: 18 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 19a ADDRESS: 20 TCCM TOWER RELOCATION 21 PROJECT TITLE: 22 5'-0" MIN 22A 18a 14. SEISMIC GAPS WHERE NOTED ARE DIMENSIONED CLEAR BETWEEN WALL FINISHES. THIS GAP TO BE MAINTAINED ENTIRELY CLEAR TO ALLOW FOR DIFFERENTIAL BUILDING MOVEMENT. NO PIPES, CONDUITS, ETC SHALL BE LOCATED WITHIN THE GAP. PROVIDE FLEXIBLE COUPLINGS AT ALL UTILITIES CROSSING SEISMIC GAPS. 17a 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS ROOF FRAMING PLAN 1/8" = 1'-0" PLAN NORTH DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S2.2 SHEET RIM A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com FRAMING PLAN NOTES: 1. REFER TO SHEETS S0.1, S0.2, S1.1, S1.2, S1.3, S1.4, S5.1, S5.2, S7.1 AND S7.2 FOR STANDARD NOTES AND DETAILS. 2. LEGEND: INDICATES METAL STUD WALL. INDICATES (E) FRAMING. 88 INDICATES GRIDLINE AT FACE OF STUD (FOS). 88 INDICATES GRIDLINE AT ¢ OF COLUMN. , 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com INDICATES HSS COLUMN. INDICATES WF COLUMN. INDICATES NON-FRAME MOMENT RESISTING CONNECTION. 17a INDICATES FRAME MOMENT RESISTING CONNECTION. 17 INDICATES SFRS COLLECTOR CONNECTION, PROVIDE DOUBLE ROW OF BOLTS AT CONNECTION PER STANDARD DETAILS. W16x26 (12) C=1" V 1 S3.1 F4 G W4 ? G3 0" PERMIT SET INDICATES BEAMS SIZE, () NUMBER OF WELDED STUDS AND UPWARD CAMBER. PROVIDE STUDS @ 24"OC MAX SPACING AT ALL BEAMS SUPPORTING CONC FILL OVER METAL DECK, UNO. ADD STUDS AS REQUIRED. (NS) INDICATES NO STUDS. WHERE NO CAMBER IS SPECIFIED FABRICATE BEAM WITH NATURAL CAMBER UP. DENOTES FRAME ELEVATION. INDICATES TIE STRAP. SEE SCHEDULE FOR STRAP, NAILING AND LENGTH 17 16"x16"x8'-0" PLANTER BOX SATURATED WEIGHT = 670# MAX TYPICAL (14) LOCATIONS 18 COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 4. DIMENSIONS RELATED TO EXISTING CONDITIONS WHERE PROVIDED ARE FOR GENERAL REFERENCE ONLY. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL BUILDING ELEMENTS ARE NEW UNLESS PREFIXED WITH (E) 6. MECHANICAL, ELECTRICAL AND PLUMBING PENETRATIONS THROUGH WALLS, ROOFS OR FLOORS SHALL BE PER 2/S1.2. UNLESS SHOWN AND DETAILED ON THE STRUCTURAL PLANS. NOTIFY ARCHITECT/ENGINEER PRIOR TO ANY INSTALLATION NOT CONFORMING TO THESE DETAILS. 7. FIRE PROTECTION SYSTEM SUPPORTS TO BE LOCATED TO MAINTAIN A MAXIMUM OF (2) 500 LB MAX POINT LOADS WITH 15'-0" MINIMUM SEPARATION TO ANY STEEL BEAM. NO SUPPORTS TO BE HUNG FROM ROOF PLY. 8. SAD FOR EDGE OF SLAB, FO WALL, ETC. 9. SAD FOR TO SLAB OR TO STEEL ELEVATION. 17b G3.5 6 TYP S7.1 3. G3.5 W3 4 ___________ S3.1 30"øx30" TALL PLANTER SATURATED WEIGHT = 1160# MAX TYPICAL (8) LOCATIONS - FOR CONN SEE 5 TYP UNO HSS8x8xÊ S7.1 HSS10x8xÊ OUTRIGGER - TYP 4'-9" G4 10 S7.1 __________ 1 HSS8x8xÊ TYP 18 3 S3.1 ___________ 17b ABV 1 ___________ BLW S3.1 W2 TYP 1 1 S7.1 __________ W1 G5 2 S3.1 ___________ 3 TYP S7.1 __________ PROJECT TITLE: __________ TOP OF PARAPET FRAMING PLAN 18a SHEET TITLE: 18d 18c 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION 19a 19 OWNER: 20 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 21 ADDRESS: 22 TCCM TOWER RELOCATION 22A 10. EXISTING TO STEEL, TO FRAMING, ETC IS UNKNOWN AND SHALL BE VERIFIED PRIOR TO ANY FABRICATION. U 11. BEAM CENTERLINES TO ALIGN WITH COLUMN CENTERLINES, UNO. 12. BEAMS TO BE EQUALLY SPACED IN EACH BAY, UNO. 13. CONDUIT OR PLUMBING NOT ALLOWED WITHIN CONC FILL ON METAL DECK. 19 TOP OF PARAPET FRAMING PLAN 1/8" = 1'-0" 18d 18c 18a 14. SEISMIC GAPS WHERE NOTED ARE DIMENSIONED CLEAR BETWEEN WALL FINISHES. THIS GAP TO BE MAINTAINED ENTIRELY CLEAR TO ALLOW FOR DIFFERENTIAL BUILDING MOVEMENT. NO PIPES, CONDUITS, ETC SHALL BE LOCATED WITHIN THE GAP. PROVIDE FLEXIBLE COUPLINGS AT ALL UTILITIES CROSSING SEISMIC GAPS. 17a PLAN NORTH 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S2.3 SHEET G3.5 18 G4 (N) TOWER ROOF TOS 53'-9" W12x30 5 S5.3 17b W12x30 5 S5.3 1 RIM (N) TOWER ROOF TOS 53'-9" A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 3 S5.3 3 S5.3 1 6 S5.3 6 S5.3 TOWER TOP FLOOR 45'-0" W12x30 4 S5.3 4 S5.3 TOWER TOP FLOOR 45'-0" W12x30 19 18 18d MAINTENANCE LEVEL 35'-6" CAP £ - TYP CONN PER 10 S5.1 (E) W12x26 W27x94 SOUTH TOWER ELEVATION 3 1/4" = 1'-0" 18 EAST TOWER ELEVATION 2 1/4" = 1'-0" 17b 18 SMRF ELEVATION AT GRID G5 1 1/4" = 1'-0" 17b 18 SMRF ELEVATION AT GRID G4 1/4" = 1'-0" 17b 18 17b 1 1 S7.2 4x10 W/ BA HGR EE SAD 10" MAX TYP 2x8 RAFTER TYP W12x30 TOWER ROOF FRAMING 1/4" = 1'-0" EQ 4x10 W/ BA HGR EE 2x4 @ 16" W/ LU HGR EE TYP 3 ___________ S3.1 7 TOWER TOP FLOOR FRAMING PLAN 1/4" = 1'-0" 1 2x4 @ 16" W/ LU HGR EE TYP 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE G4 G4 L3x3xÊ - TYP AT MIDPOINT OF BEAM REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : W12x30 13 TYP AT EA S7.2 CORNER 13 TYP AT EA S7.2 CORNER PLAN NORTH 8 TYP __________ 4 S7.1 S3.1 ___________ W12x30 2 S7.2 3 ___________ S3.1 8 W12x30 11 TYP EA FACE S7.2 SAD ___________ 8 TYP __________ S7.1 4 S3.1 ___________ __________ 2x8 STRUCTURAL FASCIA - TYP 1 W12x30 G3.5 W12x30 8 TYP __________ S7.1 4 S3.1 ___________ L3x3xÊ - TYP AT MIDPOINT OF BEAM L4x4xË - TYP AROUND PERIMETER W12x30 W8x13 L3x3xÊ - TYP AT MIDPOINT OF BEAM G3.5 W12x30 (2) 2x8 HIP - TYP W12x30 W12x30 4 S3.1 13 SIM S7.2 W12x30 C8 TYP EA CORNER PER W12x30 G3.5 W12x30 3 S7.2 Pipe 4STD ___________ W12x30 G3.5 W12x30 W12x30 L4x4xË - TYP AROUND PERIMETER EQ L4x4xË - TYP AROUND PERIMETER TYP AT EA 13 CORNER S7.2 3 ___________ S3.1 PLAN NORTH 6 TOWER MAINTENANCE LEVEL FRAMING PLAN 1/4" = 1'-0" 3 ___________ S3.1 PLAN NORTH 5 CLOCK TOWER ELEVATION AND FRAMING PLANS (E) ROOF SHEET TITLE: 1 SIM __________ S4.2 W18x106 (E) ROOF 1 S4.2 __________ 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION __________ 4 4 S4.1 PERMIT SET 'd' INDICATES PROTECTED ZONE NO ATTACHMENTS TYP __________ 7 S4.1 __________ (E) W14x22 PROJECT TITLE: 7 S7.1 7 CONN PER S7.1 SIM 1 W21x62 TOF VARIES VIF OWNER: W18x106 HSS8x8xÊ VIF 16'-0" MAX INTERMEDIATE LEVEL 25'-7" W12x30 7 CONN PER SIM S7.1 INDICATES PROTECTED ZONE NO ATTACHMENTS TYP 1 'd' W18x106 INTERMEDIATE LEVEL 25'-7" W12x30 CONTINUITY £ - TYP (E) HSS CONTINUITY £ - TYP W18x106 4 S5.3 4 S5.3 6 S5.3 (E) W12x26 S5.3 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 S5.3 S5.1 ADDRESS: S5.1 WUF-W CONN PER 1 TCCM TOWER RELOCATION WUF-W CONN PER 1 (E) W12x26 CONN PER 10 CONN PER 10 1 1 'd' W10x68 CAP £ - TYP W21x62 6 S5.3 17a W18x106 W12x30 17b 'd' MAINTENANCE LEVEL 35'-6" W12x30 4 S5.3 4 S5.3 W10x68 6 S5.3 6 S5.3 VIF 16'-0" MAX W10x68 W10x68 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com INTERMEDIATE LEVEL 1/4" = 1'-0" 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC PLAN NORTH DWG NO: S3.1 SHEET SAD 16" MAX 18d SLAB EXTENSION - SAD 9" MIN RIM #5 ADHESIVE DOWEL @ 12" OC DRILL & EPOXY WITH SIMPSON AT-XP EPOXY 18c PAVERS - SAD 3" A R C H I T E C T S CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 9" MIN VIF 6" (E) CONC SLAB 2'-0" (E) COLUMNS (E) BLOCKOUT (E) GRADE BEAM 1 WATERPROOFING - SAD 4" DRAIN ROCK (E) W8x24 COLUMN (E) GRADE BEAM NATIVE SOIL (E) BASE £ & ANCHORS G4 EDGE OF SLAB EXTENSION 3/4" = 1'-0" 8 1/2" VIF 3 1'-10" HVY HEX NUT SQ £ WASHER BASE £ SAD 16" MAX (E) EDGE OF SLAB REMOVE AT BLOCKOUT AS NEEDED EDGE OF SLAB PERMIT SET COLUMN PER PLAN W/ BASE £ PER 4 3'-0" Ë"x2Ï"SQ £ WASHER & HEAVY HEX NUT - TYP DO NOT REUSE (E) NUTS AFTER REMOVAL 2 SIDES TYP AT EA WASHER Ê Ì 9 5/8" (E) W12x26 COL & BASE £ (E) GRADE BEAM Ï" MIN TYP COL PER PLAN - BASE PLATE MAY BE OFFSET UP TO 3" TO ACCOUNT FOR MISALIGNMENT OF (E) ANCHORS G4.9 45° PERMISSIBLE TO OMIT (1) ANCHOR AS NEEDED - CUT ANCHOR WITHIN 1" OF TOC 1Ó" MIN TYP (E) EDGE OF SLAB SAD 16" MAX COL PER PLAN W/ BASE £ PER 5 S4.2 COL PER PLAN W/ BASE £ PER TYP DETAILS Ó" BASE £ W/ (9) 1Ï"ø HOLES FOR (E) 1"ø ANCHOR RODS PROVIDE 45° 5Ï" MAX CHAMFER AT CORNER AS SHOWN TO ALLOW FOR ADJACENT COLUMN - VERIFY LAYOUT OF (E) ANCHORS PRIOR TO FABRICATION BASE CONN AT MOMENT FRAME GRID G4.9 4 3/4" = 1'-0" COL PER PLAN W/ BASE £ PER 4 S4.2 BASE CONN AT MOMENT FRAME GRID G4.9 & 18d 2 3/4" = 1'-0" COL PER PLAN W/ BASE £ PER 6 S4.2 (E) SOG 1 PARTIAL PLAN AT COLUMN BASE GRID G4 & 18a 1" = 1'-0" #3x18" ADHESIVE DOWEL @ 24"oc CENTERED IN (E) SOG - TYP SAWCUT LINE BLOCKOUT PER 10 S1.1 COL PER PLAN W/ BASE £ PER 6 S4.2 (E) SOG SLAB 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE (E) FOOTING 8 EDGE OF MAT SLAB 3/4" = 1'-0" REVISIONS 6" #4x30" ADHESIVE DOWEL @ 8"oc STAGGER T&B TYP REINF AT TOP PROVIDE STD 90° HOOK EA END WATERPROOFING PER ARCH 6" 6" (E) SOG 3 S4.1 __________ EDGE OF SLAB REMOVE (E) SLAB AS NEEDED AT COLUMN #3x18" ADHESIVE DOWEL @ 24"oc W/ 6" EMBED IN (E) SOG #4 @ 18"oc EW IN SLAB 5Ï" MAX TYP (E) TS COL & BASE £ TO BE REMOVED 2'-0 1/4" 7 7" TYP VIF 1'-6 1/2" 0"±3" G4.9 (E) TS COL & BASE £ TO BE REMOVED ¢ HSS COL 1" MIN TYP A PROJECT TITLE: 2" 1'-4 1/2" 2" MIN TYP COL PER PLAN (E) PAD FTG FIELD WELD OPTIONAL 9 5/8" FOR INFORMATION NOT NOTED SEE 4 S4.1 FOUNDATION DETAILS 18d SHEET TITLE: 1 1/2" = 1'-0" 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION A (E) 1"ø ANCHORS SECTION S4.2 OWNER: 3/4" = 1'-0" PARTIAL PLAN AT COLUMN BASE 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 1 ADDRESS: PARTIAL PLAN AT COLUMN BASE GRID G4 & 18d/c TCCM TOWER RELOCATION SAD 16" MAX 18" THK PAD FTG W/ #4 @ 12" EW @ BOT TOC = -0'-9" 2'-0" EDGE OF SLAB 1'-6" PER (E) DWGS 1'-5" 1Ï" HSG COLUMN PER PLAN W/ BASE £ PER 3 S4.2 #4 ADHESIVE DOWEL @ 12"OC W/ 6" EMBED IN (E) GRADE BEAM 6 (E) PAD FTG COL PER PLAN TO (E) FTG (E) EDGE OF SLAB REMOVE AS NEEDED FOR INSTALLATION OF COLUMNS 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com WATERPROOFING - SAD MAT FOOTING PER PLAN DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC TYP REINF AT BOT 5 MAT SLAB TO (E) FOOTING 1/2" = 1'-0" DWG NO: S4.1 SHEET COL PER PLAN COL PER PLAN RIM HVY HEX NUT TO FTG BASE £ 1Ï" HSG Ë"x2Ï"SQ £ WASHER & HEAVY HEX NUT Ì 13Ï" MIN LEVELING NUT #4 STIRRUPS - TYP 1Ë"ø ANCHOR W/ Ï"x3"SQ £ WASHER & DBL NUT (4) #7 CONT AT TOP & BOTTOM 6Ï" MAX A (16) #4 STIRRUPS - TYP AT EA COLUMN BASE SECTION BASE PLATE AT EXTERIOR HSS B SECTION ¢ COL & BASE £ (E) PAD FTG TO BE DEMOLISHED (4) #5 x 36" ADHESIVE DOWELS W/ 8" MIN EMBED £1Ï"x15"x23" W/ (6) 2"ø HOLES FOR 1Ë"ø ANCHORS 1/2" TYP 6 1/2" TYP (E) W12x26 COL & BASE £ TO BE REMOVED 11 1/2" G4 4" TYP 1" GRID, ¢ COL & BASE £ £ TO £ 3 SIDES - FIELD WELD OPTIONAL Ì A (E) EDGE OF SLAB 1'-4 1/2" MIN Ì B 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com W18 COL PER PLAN Í THICKENED SLAB EDGE 1'-5 1/2" (E) GRADE BEAM 1'-4" 1 (4) #7 AT TOP AND BOTTOM TYP GRID 4" HSS TO £ HSS TO £ 1'-2" 18 1" = 1'-0" FOR BALANCE OF INFO SEE 3 S4.2 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com BOT OF MAT BEYOND 2 SIDES TYP AT EA WASHER Ê 3 1"ø ANCHOR W/ Ï"x3"SQ £ WASHER & DBL NUT A R C H I T E C T S 8" MIN HSS 12x8 TYP TO FTG TYP REINF 2'-3" AT THICKENED EDGE 1'-1" Ó" BASE £ W/ (4) 1Ë"ø HOLES FOR Ó"ø ANCHORS TO CONCRETE BELOW W/ 9" MIN EMBEDMENT - ADJUST ANCHOR LOCATION AS NEEDED TO MEET EDGE DISTANCE AND SPACING REQUIREMENTS. USE ADHESIVE ANCHORS WHERE CONNECTING TO (E) CONCRETE. 3" CLR 2" TYP SQ £ WASHER 1Ï" 1'-4" PERMIT SET BASE PLATE AT EXTERIOR HSS (AT CONFLICT W/ (E) BASE PLATE) 1" = 1'-0" 1 COLUMN BASE AT MOMENT FRAME GRID G4 3/4" = 1'-0" FOR BALANCE OF INFO SEE 3 S4.2 2" 2" £Ó 4" 2" F4 BASE PLATE AT EXTERIOR HSS ('L' SHAPED) (E) GRADE BEAM 1'-8" 1" = 1'-0" CHIP OUT (E) SLAB AS NEEDED FOR COLUMN INSTALLATION 3'-0" 1'-4" EQ (E) GRADE BEAM 2" TYP #4 ADHESIVE DOWEL @ 12"OC W/ 6" EMBED IN (E) GRADE BEAM 18" THK PAD FTG W/ #3 @ 6" EW @ BOT TOC = -0'-9" EQ 9" EQ Ó" BASE £ W/ (4) Ó"ø ADHESIVE ANCHORS TO CONCRETE BELOW W/ 6" MIN EMBEDMENT - ADJUST ANCHOR LOCATION AS NEEDED TO MEET EDGE DISTANCE AND SPACING REQUIREMENTS. 3" CLR TYP EQ COL PER PLAN W/ BASE £ PER 3 S4.2 17.86° W4 2'-0 5/16" 5 2" V PROJECT TITLE: 3/8" TYP 4" 2" 2" HSS 12x8 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE 3 S4.1 __________ TYP 6 1" = 1'-0" EDGE OF SLAB HSS 8x8 Ì BASE PLATE AT INTERIOR HSS FOUNDATION DETAILS 4 SHEET TITLE: Ê 2 SIDES TYP AT EA WASHER 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION Ï"x3"SQ £ WASHER & HEAVY HEX NUT - TYP EDGE OF MAT SLAB ADDRESS: HSS TO £ EDGE OF SLAB EXTENSION TCCM TOWER RELOCATION 3 S4.1 __________ OWNER: £1"x11Ï"x17" 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 £Ï"x9"x12" 2 PARTIAL PLAN AT COLUMN BASE NEAR GRID W4 3/4" = 1'-0" REVISIONS DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 NJR NJR 2015 RIM ARCHITECTS LLC DWG NO: S4.2 SHEET AT UNTOPPED CONDITION SEE & A B t-É" 3-8 (Ê" MIN, Ì" MAX) AT METAL DECK k det BM PER PLAN FULL DEPTH STIFFENER/CONN £ WHERE NOTED W BM PER PLAN CONN £ 5 DBL ROWS OF BOLTS ES OF COL AT Ê NOTE: WHERE CONTINUITY PLATES CONFLICT W/ THIS DETAIL, USE THICKER PLATE & DEEPEN CONN £ AS SHOWN DASHED 3/4" = 1'-0" CONNECTION PER __________ 9 (50-00-03) S5.1 1/4" 1/2" MAX £ Ë", ALIGN W/ ¢ OF BM WEB 2"2" DIM BASED ON ARCH PLANS 'd'/4 MAX FULL DEPTH STIFF £ (1) £ PER 5 __________ S5.1 ANGLE BRACE 11 (Õ"ø 50-01-01 Ó"ø 50-01-02 1"ø 50-01-04) BEAM TO COLUMN WEB 8 3/4" = 1'-0" A 'd' AT BEAM PARALLEL B AT BEAM PERP TOP OF BRACE ADD TAB TO MATCH BM WEB AS REQD TO MATCH BOLTING SPECIFIED FOR BM (WELD TAB PRIOR TO BOLTING) 3/4" = 1'-0" A GIRDER FULL DEPTH STIFF £ (1) £ PER 5 - 1/4" Õ"ø HSB 2" 3" Ë 2" AT BEAM PARALEL NOTE: WHERE 'X' > 18" PROVIDE ANGLE BRACE PER W/ TOP CONN 4 MIN B PER __________ 8 (50-00-02) S5.1 5 £ Í" Ì" A R C H I T E C T S W21 5 £ Ï" Í" W24 6 £ Ï" Í" W27 7 £ Ï" Í" W30 8 £ Ï" Í" CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com W33 9 £ Ï" Í" W36 10 £ Ï" Í" 2. HIGH STRENGTH BOLTS (HSB) ARE A325-N UNO. PREPARE MATING SURFACES & TIGHTEN "SNUG TIGHT" AS DEFINED IN THE SPECIFICATIONS. 3. USE ASTM A36 CONNECTION PLATES, UNO. 4. A COMPLETE PENETRATION BEVEL WELD MAY BE SUBSTITUTED FOR THE FILLET WELDS SPECIFIED. 5. HOLE SIZE = BOLT SIZE +È". SHORT SLOTTED HOLES (+È" VERT, + Ë" HORIZ) MAY BE SUBSTITUTED (EXCEPT AS NOTED) ROUND HOLES ARE REQUIRED AT SFRS CONNECTIONS. 6. USE SAME CONNECTIONS AT CHANNELS. FOR W6, C6 & ANGLES USE PLATE, WELD & BOLT SIZE PER W8 & SEE 4/S5.1. 3/4" = 1'-0" 1. SEE SPREADSHEET S:\_CalcSpreadsheets & Design Tables\_CalcSpreadsheets\CBC_13_IBC12\Steel\Steel Shear Tab Design. R 3/4" R S5.1 ADD TAB TO MATCH BM WEB AS REQD TO MATCH BOLTING SPECIFIED FOR BM (WELD TAB PRIOR TO BOLTING) * * * R MIN __________ DBL ROWS OF BOLTS ES OF BM AT 2" Ê ONE SIDED CONNECTIONS CONNECTIONS WHERE BM DEPTH VARIATION, x, EXCEEDS 6" CONNECTIONS INTO SLFS BEAM OR GIRDER SEE TYP COPE LOWER FLANGE AT FULL DEPTH CONN £ 3" R 1 FOR CONN PLATE, BOLTS, & WELD S5.1 __________ (Õ"ø 50-01-01 Ó"ø 50-01-02 1"ø 50-01-04) 3" 2" 1Ï x DBL ROW OF BOLTS AS REQD FOR BOLT FIT SAD L3x3xÊ BRACE 1 MAX R MIN (51-01-02) 2 1/4" R (50-00-02) 3" 2" (52-02-01) 10 S5.1 SEE FOR DIMENSIONS, ETC & __________ 1 FOR CONN £, BOLTS & WELDS __________ (Õ"ø 50-01-01 Ó"ø 50-01-02 1"ø 50-01-04) FULL DEPTH CONN £ Õ"ø HSB S5.1 12 2 B BEAM TO COLUMN CONNECTION 9 3/4" = 1'-0" C 6 L 3/4" = 1'-0" CHECK BRACE FOR R , CAP = 5.3K BASED ON BOLT GOVERNING CONN. MF BOTTOM FLANGE BRACING MAY REQUIRE HSB OR ADDL BOLTS. FOR INFORMATION (51-01-02) NOT NOTED SEE __________ 3 S5.1 3/4" = 1'-0" USE HSB FOR STEEL BLDGs - CHECK CONN CAP) (METAL DECK & CONC 1"ø WD FRAMED FLRs & RFs Ó"ø OK (PARTIAL HT CONN £ ARE NOT APPROVED BY DSA) R FOR BEAMS BOTH SIDES COPE LOWER FLANGE AS REQD FOR INSTALLATION, TYP C AT BEAM PERPENDICULAR OR DECK TYPICAL BEAM BOTTOM FLANGE BRACE 3" TYPICAL BEAM TO BEAM CONNECTION Ó" R MIN BM WHERE OCCURS R MIN 3" TYP PLATE Ë"x5"x5" OR FULL DEPTH STIFFENER PLATE PER OTHER DETAILS TYPICAL BEAM TO BEAM CONNECTIONS 3/4" = 1'-0" TYP R MIN COPE LOWER FLANGE AS REQD FOR INSTALLATION BM AS OCCURS CAP £ SAME THICKNESS AS COL WEB (Ë" MIN, Ï" MAX) R 3/4" MAX FULL DEPTH CONN £ CONN £ DBL ROWS OF BOLTS ES OF COL AT ES (50-01-01) BM AS OCCURS BM PER PLAN PER SCHED Ë R 3" TYP CROSS £ SAME THICKNESS AS COL WEB (Ë" MIN, Ï" MAX) COL PER PLAN SEE FOR 'x' Ä 30° BEVELED BACK UP BAR WHERE REQD CONN PLATE NOTES: WHERE WELD IS REQD AT TOP OR BOT OF CONN £ AND ACCESS IS LIMITED TO ONLY ONE SIDE OF £, PROVIDE COMPLETE PENETRATION WELD OF CONN £ IN LIEU OF DOUBLE SIDED FILLET WELD. BOLTS PER SCHED R CONN £ PER SCHED COL PER PLAN (52-02-02) 3 1 FOR CONN £, BOLTS, & WELD S5.1 __________ TYPICAL FULL DEPTH BEAM TO BEAM CONNECTION 3/4" (FOR =ALL 1'-0" STEEL BLDGs & DSA 1-SIDE) CJP BM WEB DBL ROWS OF BOLTS ES OF COL AT 3" 11 S5.1 SEE FOR DIMENSIONS, ETC & __________ 1 FOR CONN PLATE, BOLTS & WELDS S5.1 BM WEB 'x' CONNECTION PLATE R MIN R 13 SEE 3/4" = 1'-0" 10 1 FOR CONN PLATE, BOLTS, & WELD S5.1 __________ 3/4" = 1'-0" 3" R MIN (Õ"ø 50-01-01 Ó"ø 50-01-02 1"ø 50-01-04) BEAM TO COLUMN FLANGE CONNECTION 7 SKEWED BEAM CONNECTION - AT WEB 1 1/2" = 1'-0" SEE 4 1 FOR CONN PLATE, BOLTS, & WELD S5.1 __________ TYPICAL SHALLOW BEAM DETAIL 3/4" = 1'-0" DATE REVISIONS R PER TYP DETAIL INCREASE AS REQD FOR BOLT CLEARANCES (Õ"ø 50-01-01 Ó"ø 50-01-02 1"ø 50-01-04) NO DESCRIPTION W6, C6 AND SMALLER OR L __________ BEAM TO COLUMN CONNECTION PERMIT SET R MIN 3" TYP TYP CJP COPE LOWER FLANGE AS REQD FOR INSTALLATION 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com Õ"ø HIGH STRENGTH BOLT (HSB) CONNECTION SCHEDULE PROVIDE FULL DEPTH CONN £ PER __________ 3 FOR: 8 S5.1 TOP CONN SEE RIM R = 1Ó" MIN, SEE TYPICAL CONNECTION DETAILS. BOLT SPACING AND EDGE DISTANCE SHALL CONFORM TO AISC SPECIFICATIONS. 1 B CONN £ COL PER PLAN W18 1/2" MAX 45° MAX 'X' CAP £ SAME THICKNESS AS COL WEB (Ë" MIN, Ï" MAX) Ë Ì" 4. ENGINEER SEE X-ARCHIVE FOR OLD SCHEDULES. (50-00-01) ES £ Í" S5.1 Ñ"x4" BAR A 4 3. NOTE HEAVY W18's OR SLOPED W18"s MAY NEED TO REDUCE VERTICAL EDGE DISTANCE DURING FABRICATION, SUGGEST ADDRESSING DURING CA IF REQD. SLOPE SAD __________ DBL ROWS OF BOLTS ES OF COL AT W16 MIN SFRS CONNECTIONS ARE CONN £ REQUIRED. 2. ENGINEER MUST DESIGNATE (ON PLAN OR DETAILS) WHERE PARALLEL BM FULL DEPTH CONN £ BEAM AS OCCURS Ì" 1. CJP (50-00-01) 1 SEE __________ FOR CONN £, BOLTS, & WELD S5.1 £ Í" NOTES: TYPICAL BEAM WEB STIFFENER PLATE DETAIL 2" CONN £ TO CROSS £ AND CROSS £ TO COL FLANGE W COL PER PLAN 3 STEEL FRAMING DETAILS TYP AT EA FLUTE 1 4 FLUTES MIN É Ó"ø MB W12, W14 SHEET TITLE: C Ì" 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION BM AS OCCURS £ Í" OWNER: 3/4" MAX R 2 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 BOTH SIDES ANGLE BRACE W8, W10 ADDRESS: Ï" CROSS £ T&B (OR CONTINUITY £ PER OTHER DETAILS) PARTIAL DEPTH STIFFENER PLATE TYP UNO. £ TO BE SAME THICKNESS (t) AS BM WEB (Í" MIN, Ï" MAX), Ó" MAX AT W40. MATCH WIDTH OF BEAM FLANGE. CHAMFER £ AT BEAM FILLETS, TYP (NO WELD AT FILLETS) k det ALTERNATE CONN: (1) Ó"ø MB WELD SIZE TCCM TOWER RELOCATION 2Ï CONN. PLATE k1 1 1/4" Ë NO. BOLTS PER ROW BEAM DEPTH PROJECT TITLE: L5x3xÊ LLV, LENGTH AS REQD FOR CONN TO DECK 1Ë " (3) SHEAR STUDS AT CONC FILL (Ó"ø 50-01-01B 1"ø 50-01-01) DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S5.1 SHEET t TYP CUT & SPLICE HSS COL W/ CJP WELD t d TYP K 1 1/2" 1 1/2" tf RIM K A R C H I T E C T S tf TYP TYP CASE 2 CJP tf-Ë" tf MIN 3 1/2" A A CJP PLAN VIEW SPLICE £ Ï" W/ (4) LIFTING BOLTS t DBL ROWS OF BOLTS ES OF COL AT CASE 1 8" A 3" A LIFTING HOLE IN SPLICE £ 1 1/2" SHIM AS REQD HSS 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com HSS FOR INFORMATION (52-01-05) NOT NOTED SEE __________ 6 S5.2 BEAM TO HSS COLUMN (2-WAY) 3/4" = 1'-0" A 4 TYPICAL HSS TO HSS CONNECTION 1 3/4" = 1'-0" COLUMN SPLICE 3/4" = 1'-0" COVER £ THICKNESS "t" = HSS WALL THICKNESS (Í" MIN) 1/2" ES 1/2" OVERSLOT DUE TO KNIFE £ GEOMETRY FOR USE ONLY WHERE SPECIFICALLY NOTED 2" SEISMIC GAP 1/2" MAX Ê BACK-UP BAR SNUG FIT £Ë" W/ (4) 3Ï"SDS TO POST (GAGE =3") 1/2" MAX OVERSLOT WOOD POST PER PLAN SLOT AT END OF HSS 5 HSS SPLICE 2 3/4" = 1'-0" SLOT IN MIDDLE OF HSS TYPICAL SLOTTED HSS FOR GUSSET CONNECTION 1 1/2" = 1'-0" SEAL WELD É "t" - È" (Ê" MIN) "t" OFFSET CONN £ É "t" ¢ BM & COL A "t" - È" (Ê" MIN) STEEL BEAM AT WOOD POST 3/4" = 1'-0" £ THICKNESS +1/8" MAX PLAN VIEW AT COLUMN TOP OF COL AS OCCURS W/ CAP £ PER __________ 3 S5.2 1/2" COL PER PLAN SEAL WELD STEEL FRAMING DETAILS KNIFE £ SHEET TITLE: 3" HSS PER ELEV 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION CJP 1/2" MAX OVERSLOT EA END HSS MEMBER PER PLAN OWNER: £ THICKNESS + 1/8" MAX 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 PREDRILL HOLE PRIOR TO CUTTING SLOT. HOLE ø = £ THICKNESS + Ë", TYP ADDRESS: STEEL BEAM PER PLAN TCCM TOWER RELOCATION A SPLICE LOCATION PER ELEV AS REQD 8 PERMIT SET t-É ROOF PLY ADJACENT BUILDING £ THICKNESS + 1/8" MAX PROJECT TITLE: 7 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com AT BEAM ALTERNATE (52-01-02) SLOT COL FOR £ THRU PER __________ 2 BM AS OCCURS CONTINUE £ FOR BM BOTH SIDES S5.2 A (52-01-01) (50-01-01) 1 S5.1 SEE FOR CONN £, BOLTS & WELD __________ CONN £ TYP NS & FS £ TO MATCH HSS WALL THICKNESS (Ë" MIN, Ï" MAX) TYP SEAL WELD NO DESCRIPTION SEAL WELD 6 BEAM EACH SIDE TO HSS COLUMN 3/4" = 1'-0" REVISIONS W BEAM DBL ROWS OF BOLTS ES COL AT AT COLUMN 3 TYPICAL CAP PLATE 3/4" = 1'-0" AT BEAM DATE DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S5.2 SHEET 2. 2. LARGER OF tñô OR Ï". (PLUS Ï tñô MINUS Ë tñô) TYP CONN PER TYP DETAILS W/ HSB-SC Ì Ï 3. Ó tñô TO tñô, Ó" MINIMUM (±Ë") Ï Ì 3 SIDES - TYP COL PER PLAN 3 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com FOR INFORMATION NOT NOTED SEE 2 S5.3 OMRF STRONG AXIS CONN AT ROOF 1" = 1'-0" WELD ACCESS HOLE DETAIL CJP - TYP SMRF MOMENT CONNECTION ONE SIDE 1 COL PER PLAN 3/4" = 1'-0" 3/4" = 1'-0" Ì 7 WELD ACCESS HOLE PER S5.3 TYP CONN PER TYP DETAILS W/ HSB-SC Ï A TYP CONTINUITY PLATE CJP OMRF STRONG AXIS CONN COLUMN 1" = 1'-0" ¢ CONN £ & BEAM Ì WELD ACCESS HOLE PER CAP £ STIFF £ PER TYP DETAILS 7 TYP S5.3 CONN PER TYP DETAILS W/ HSB-SC Ì A CJP BM TO COL PER NOTE #2 CONN £ PER NOTE #3 WELD PER NOTE #5 BEAM BACKING BAR, TYP BEAM CONN PER 11 S5.1 t/2 Ë" MIN Ï" MAX REMOVE BACKING BAR BACKGOUGE AND REWELD OMRF WEAK AXIS CONN AT ROOF Ì WELD ACCESS HOLE PER STIFF £ PER TYP DETAILS CJP t > 1" MOMENT CONNECTION NOTES: 1. CJP GROOVE WELD AT TOP AND BOTTOM FLANGES. AT TOP & BOTTOM FLANGE, REMOVE WELD BACKING, BACKGOUGE, AND ADD Ì" MINIMUM FILLET WELD. WELD: QC/QA CATEGORY AH/T. 3. SHEAR TAB OF THICKNESS EQUAL TO THAT OF BEAM WEB (Í" MIN). SHEAR TAB LENGTH SHALL BE SO AS TO ALLOW É" OVERLAP WITH THE WELD ACCESS HOLE AT TOP & BOTTOM, AND THE WIDTH SHALL EXTEND 2" MINIMUM BACK ALONG THE BEAM, BEYOND THE END OF THE WELD ACCESS HOLE. COL PER PLAN CONT £ UNO 2. CJP GROOVE WELD FULL LENGTH OF WEB BETWEEN WELD ACCESS HOLES. PROVIDE NON-FUSIBLE WELD TABS. REMOVE WELD TABS AFTER WELDING AND GRIND END OF WELD SMOOTH AT WELD ACCESS HOLE. WELD: QC/QA CATEGORY BH/T. 1" = 1'-0" 7 S5.3 PJP CONN £ TO COL PER NOTE #4 BEAM PER PLAN Ì CJP PER NOTE #1 ACCESS HOLES PER CONTINUITY £ THICKNESS SAME AS BM FLANGE tô, Ï" MIN CONT £ 5 Ì (3) ERECTION BOLTS TO MATCH SIZE & TYPE OF TYP CONNECTORS CONN £ PER TYP DETAILS COL PER PLAN INDICATES WELDS PER BELOW 1/4" CLR MOMENT FRAME DETAILS REMOVE BACKING BAR BACKGOUGE AND REWELD 2" MIN CLR 4 Ì COL k + 1 1/2" SHEET TITLE: BEAM PER PLAN tñô CONT £ - TYP PERMIT SET Ï" MIN RADIUS 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION TYP tñô Ï" MIN 7 DBL BOLTS 1/8" OVERLAP SHEAR TAB/ WELD ACCESS LOWER ACCESS HOLE SURFACES SHALL BE FREE OF NOTCHES AND GOUGES. SURFACE ROUGHNESS SHALL NOT EXCEED 500 MICRO INCHES. CONTINUITY £ THICKNESS SAME AS BM FLANGE tô, Ï" MIN COL kþ 2. BM AS OCCURS REMOVE BACKING BAR BACKGOUGE AND REWELD R 3. tñô Ì CONT £ - TYP TOLERANCES SHALL NOT ACCUMULATE TO THE EXTENT THAT THE ANGLE OF THE ACCESS HOLE CUT TO THE FLANGE SURFACE EXCEEDS 25 DEGREES. BEAM PER PLAN tñô 6. SEE SPECIFICATIONS. 4. 6. 1. tñô Ï" MIN 5. 3 tñô (±Ï") 5. CJP tô/4 Ë" MIN OWNER: 4. Í" MINIMUM RADIUS (PLUS NOT LIMITED, OR MINUS 0) tô/4 Ë" MIN 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 UPPER ACCESS HOLE CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com ADDRESS: 5. CJP AT DBL BOLTING A R C H I T E C T S TCCM TOWER RELOCATION 4. Ó" CAP £ 2 NOTE #1 S5.3 PROJECT TITLE: 1. ANGLE AS REQUIRED FOR SPECIFIED GROOVE WELD PROCEDURE. CJP PER 7 WELD ACCESS HOLE PER TYP S5.3 tô NOTES: RIM tô 6. tñô CJP t > 1" 1" CLR 1. 3. Ì UNO tô/2 Ë" MIN Ï" MAX CAP PLATE TO MATCH COL WIDTH AND BEAM FLANGE THICKNESS (tô) 1" MIN 7 TYP S5.3 CONN PER TYP DETAILS W/ HSB-SC CONN £ PER TYP DETAILS 4. FULL LENGTH PARTIAL JOINT PENETRATION (t - É") FROM FAR SIDE OF BEAM WEB, WITH FILLET WELD OVER EQUAL TO CONNECTION PLATE THICKNESS. WELD: QC/QA CATEGORY BM/T. 5. FILLET WELD SHEAR TAB TO BEAM WEB. WELD SIZE SHALL BE EQUAL TO THE THICKNESS OF THE SHEAR TAB MINUS È". WELD SHALL EXTEND OVER THE TOP & BOTTOM ONE-THIRD OF THE SHEAR TAB HEIGHT AND ACROSS THE TOP AND BOTTOM. WELD: QC/QA CATEGORY BL/L. 6. QC/QA = QUALITY ASSURANCE PER AISC 341. NO DESCRIPTION DATE REVISIONS BEAM PER PLAN CONT £ Ì 6 OMRF WEAK AXIS CONN 1" = 1'-0" REMOVE BACKING BAR BACKGOUGE AND REWELD 2 SMRF MOMENT CONNECTION 2 SIDES 3/4" = 1'-0" DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S5.3 SHEET RIM A R C H I T E C T S HSS (E) BEAM ¢ WTS, HTT5, STRAP & SB 1" MIN 1Ï" MAX TYP 3 SIDES DBL 4x6 FLAT SB - CUT FOR FULL BRG Ì COL PER PLAN 1 (2) HTT5 EA COLUMN Ì Ì Í 1'-3" Ñ"ø WTS TO COL TYP EA HTT5 A 5" 5" A STRAP BEAM PER PLAN Í CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com COLUMN 1'-8" MSTD5 MARRIAGE STRAP EA HTT5 TO CMSTC16 Í TYP Ì (E) COL £ 3/8" CMSTC16 x 20'-0" EA HTT5 NAIL ALL HOLES COLUMN PER PLAN 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com HTT5 (E) JOIST STIFF £ 2" Ì HSS PER PLAN L3x3xËx12" CTD ON HSS (E) JOIST (E) NAILER - REPLACE LOCALLY AT L3 CONT DBL 4x6 FLAT SB W/ (6) 10d TN EE EA BLK 3 COLUMN CONN AT GRID G4.9 (SOUTH OF 19) PLAN 1" = 1'-0" (E) CONT £ £Ïx4x9 CTD ON STIFF £ (E) COL STIFF £ PERMIT SET Ñ"ø WTS OR THROUGH 1 BOLT TO COL FLANGE COLUMN TIE-IN AT GRID G4 & 18a, 18c (2) HTT5 EA COLUMN 1" = 1'-0" (E) BEAM MSTD5 MARRIAGE STRAP EA HTT5 TO CMSTC16 3" MAX CONN PER TYP DETAILS TYP 4 3 SIDES, TYP (E) BEAM (E) COL Í Í Ë SECTION COLUMN PER PLAN 1 COLUMN TIE-IN AT GRID G4.9 & 18d COLUMN TIE INTO DIAPHRAGM AT GRIDS W1, W2 & W3 1" = 1'-0" 1" = 1'-0" 1 (2) HTT5 EA COLUMN Ñ"ø WTS TO COL TYP EA HTT5 MSTD5 MARRIAGE STRAP EA HTT5 TO CMSTC16 CMSTC16 x 20'-0" EA HTT5 NAIL ALL HOLES TO 4x8 STRUT BELOW (E) BEAM BEVELED WASHER 3 SIDES - BENT £ TO BEAM WEB Ì (E) NAILER - NOTCH AS NEEDED AT HSS - PROVIDE SHIMS AS NEEDED FOR TIGHT BEARING 5 (E) JOIST COMPRESSION NUT BEVELED WASHER HUCQ8 L12x5xÍ x 0'-6" BENT PLATE EACH SIDE CONT DBL 4x8 STRUT AT FRAMING PERP TO WALL - PROVIDE TF HGR EE 3 SIDES (E) BEAM Ì REMOVE & REPLACE (E) JOIST AT CONFLICT 5 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE COL PER PLAN REVISIONS 5" TYP 5 COL PER PLAN COLUMN TIE-IN AT STRUT NEAR GRID G4 & 18d 1" = 1'-0" 2 WOOD DETAILS 4" 3 SIDES Ê (E) JOIST SHEET TITLE: £ Í"x2"x8" 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION CONT DBL 4x6 FLAT SB W/ (6) 10d TN EE EA BLK £ Ï"x8"x14" OWNER: COL PER PLAN ADDRESS: Í TCCM TOWER RELOCATION COLUMN BEAM PER PLAN 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 CMSTC16 x 20'-0" EA HTT5 NAIL ALL HOLES PROJECT TITLE: 6 " 1'-0 TYP Õ"ø THREADED ROD INSTALLED THROUGH DRILLED HOLE IN (E) STEEL BEAM & BENT PLATE - TYP EA HUCQ8 4x STRUT PER PLAN PROVIDE LUS HGR EE 1 DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC COLUMN ROOF TIE IN AT GRID W4 1" = 1'-0" DWG NO: S6.1 SHEET HSS SAD 43 MIL FURRING WALL STUD AS OCCURS - SAD 30"ø PLANTER A FLOOR PEN TYP Ê 1/4" 1/2" TYP OUTRIGGER BEAM PER PLAN 7" Í TYP Ê 2x4 1'-3 1/2" VIF HSS PER PLAN TRELLIS Ñ"ø WTS @ 32" (E) COLUMN 4x NAILER PER TYP DETAILS FLOOR PLY 3'-4" ¢ HSS 2 EQ ±Ï" 1" = 1'-0" 1'-4 1/2" SAD PERMIT SET £Õ"x7"x10" £1"x11" SQ TYPICAL WALL STUD B11 STRUT 1'-0" HSS PER PLAN 8 5 1 1/2" = 1'-0" TRACK HSS BELOW ROUND PLANTER WALL STUD OUTRIGGER BEAM PER PLAN 7" 1" = 1'-0" ¢ HSS EQ ±Ï" PLANTER BEAM PER PLAN HEADER Ï"ø U-BOLT TYP AT EA STRUT SECTION AT TOWER WALL OUTRIGGER BEAM PER PLAN TYPICAL WALL STUD HSS PER PLAN EQ ±Ï" STUD ABV 16"x16" PLANTER 1" TYP OUTRIGGER TO COLUMN CONN 1" = 1'-0" Í" 1" TYP EQ B11 STRUT @ 24"oc 9 TYPICAL STUD SPLICE AT NON-BRG WALL 6 1 1/2" = 1'-0" C TRELLIS POST CJP BASE £ Õ"ø HOLE FOR Ñ"ø WTS - TYP 1Ï" TYP 1" = 1'-0" A B SAD 5'-9" MAX TOWER COLUMN PER PLAN/ELEVATION NAILER PER TYP DETAILS SAD 7'-6" MAX SAD 1'-9" MIN C TYP HSS 3x1ÏxÉ TRELLIS JOIST SAD FOR SPACING (42" MAX) SPLICE PER B 5 1/2" EQ EQ (E) TRANSOM BEAM W/ NAILER T&B AS OCCURS Ì HSS BELOW 16"x16" PLANTER £1"x12"SQ BASE PLATE W/ (4) Õ"ø HSB TO BEAM BELOW (GAGE = 5Ï") (E) WALL STUD PROJECT TITLE: STUD BLW TYP Ì Ï"ø U-BOLT TYP AT EA STRUT Í HSS 5x4xÊ TRELLIS BEAM - SPLICE PER AS NEEDED TYP HSS TRELLIS POST PER OTHER DETAILS B HSS 4x4xÊ TRELLIS POST 1 A Ì 1 PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE 1 REVISIONS £Ñ"x6"x10" BASE £ DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : WTS, NUT & WASHER BEAM PER PLAN BEAM AS OCCURS BEAM PER PLAN HSS PLANTER BEAM PER PLAN 10 TRELLIS POST TO PLANTER BEAM CONN 3/4" = 1'-0" 7 TOWER COLUMN CONNECTION AT ROOF BEAM 1" = 1'-0" (E) BEAM W/ NAILER T&B (E) COLUMN AS OCCURS POST HSS PER PLAN (E) JOIST TYP BEAM ¢ STUD SPLICE TRACK TO MATCH GAGE AND DEPTH OF STUD (43 MIL MIN) W/ (4) #8 SMS TO EACH STUD AS SHOWN COLUMN PER PLAN CAP £ W/ SEAL WELD Ëx2 BENT £ W/ Ï"ø MB TO PLANTER TYP AND Ï"ø MB W/ CHANNEL NUT TO STRUT 1'-0" EQ 3 4 TYPICAL SECTION AT TRELLIS 3/4" = 1'-0" MISCELLANEOUS DETAILS BEAM PER PLAN SHEET TITLE: SEE 1/S1.3 NOTE #2 2 S7.1 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION 1" MAX FOR BALANCE OF INFO SEE OWNER: Ëx2 BENT £ W/ Ï"ø MB TO PLANTER TYP AND Ï"ø MB W/ CHANNEL NUT TO STRUT - TYP 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 L3x3xÊ A Ê ADDRESS: TYP 2 3 S7.1 S7.1 30"ø PLANTER JOIST PER PLAN ROUND PLANTER PER PLAN 1'-7" OUTRIGGER TO COLUMN CONN (AT GL W1, W2 & W3) 1/4" EQ ±Ï" CONT L4x4xË W/ Ï"ø MB AT EA L3 - HOLES FOR MB MAY BE FIELD DRILLED 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com PLANTER BEAM PER PLAN W/ CONN PER TYP DETAILS £Õ ES TCCM TOWER RELOCATION 12" MAX CJP 3 SIDES - TYP 10d @ 6" 9 S7.1 3" ¢ STRUT FASTCLIP SIDE CLIP (FCSC) 14 GA EA STUD W/ (3) PAF TO ANGLE ¢ SPLICE AS NEEDED PER CJP, TYP 6'-6" MAX 4" MIN TYP 600S162-43 @ 8'-0" MAX W/ (4) #12 SMS TO EACH STUD AS SHOWN 400S162-97 x 30" ES HSS W/ (6) PDP @ 1Ë" OC EW T&B TO HSS AS SHOWN CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com 1 6'-3" MAX VIF 4" MIN TYP A R C H I T E C T S Ñ"ø WTS, WASHER & NUT - TYP 1" ¢ 30"ø PLANTER 10 1/2" ±Ï" Ó" MIN TYP WALL STUD PER SCHEDULE TRELLIS POST & BASE £ 3" SAD Ê 2"x2"x6"x97 MIL BENT £ W/ (4) #12 SMS EA LEG 10 1/2" ±Ï" SAD 2" MAX £1"x11" SQ TYP 10" ¢ STRUT RIM Ë" CAP £ 1000T150-68 TRACK 1 TYPICAL WALL SECTION AT PIER 1/2" = 1'-0" 2015.03.31 13529 DDW NJR 2015 RIM ARCHITECTS LLC DWG NO: S7.1 SHEET 2'-0" TYP PIPE COL PER PLAN 4 S7.2 Ï" x 6" SQ BASE £ __________ 2 S7.1 1 __________ 1000T150-68 TOP TRACK TOWER TOP LEVEL, SAD 12 S7.2 10 S1.4 HEADER __________ 2 S7.1 __________ 1000S162-43 STUD, TYP ABOVE HEADER 1 CALIFORNIA ALASKA HAWAII GUAM 300 CALIFORNIA STREET SUITE 220 SAN FRANCISCO, CA 94104 Phone: 415.247.0400 Fax: 415.247.0401 www.rimarchitects.com CONT SB 3x8 NAILER W/ Ñ"ø WTS @ 16"OC DOUBLE STUD AT JAMB, TYP JAMB 1 BLOCKING PER __________ TYP S1.4 6 S1.3 __________ CLOCK BY OTHERS - SAD SILL 1 SECTION AT TOWER ROOF 7 S5.2 CONN £ PER USE THICKNESS AND WELD SIZE FOR W8 Í" x 6" SQ CAP £ FOR SPIRE CONNECTION 7 S7.2 __________ Ì MAINTENANCE LEVEL, SAD 6 TYP S7.2 9 S1.4 LSSU HGR - TYP RAFTER PER PLAN A34 TYP ROOF PLY STRUCTURAL FASCIA 3" __________ TYP RIDGE BEAM PER PLAN ROOFING - SAD 3" SAD 15'-0" MAX 1 100 BUSH STREET | SUITE 1850 SAN FRANCISCO, CA | 94104 415.243.4091 | zfa.com 3/4" = 1'-0" 2Ï" WALL BLOCKING PER 1 S1.4 HSS COLUMN JAMB OPEN BEAM PER PLAN 800S162-68 STUD, TYP SAD 19'-0" MAX JAMB JAMB HSS COLUMN JAMB CK R CLO G FO CONT STRUCTURAL FASCIA W/ A34 EA RAFTER BEAM PER PLAN TOF BEYOND INDICATES CONNECTION STRAP LOCATION IN Ê A R C H I T E C T S HEADER 54 MIL SOLID BLKG - CLIP FLANGE EE, BEND WEB AND FASTEN W/ (4) #8 TO HEADER/SILL/JAMB - TYP OPEN RAFTER PER PLAN W H2.5A TO NAILER 10 S1.4 3 S1.3 __________ RIM LSSU HGR Ê 10 TYP S7.2 ø 76É" 1'-6" 1 RAFTER PER PLAN W/ LSSU HGR EE PERMIT SET RIDGE BEAM PER PLAN PIPE COLUMN PER PLAN TYPICAL ELEVATION AT FACADE FRAMING WALL STUD (2) PDP ES EA STUD 5 S7.2 __________ 600S162-43 @ 16"OC EIFS 600T150-43 TRACK W/ 3Ï" SDS @ 16" OC TO 4x RAFTER PER PLAN LEVELED FLOOR - SAD 8" MIN - EXTEND AS NEEDED FOR ATTACHMENT 4" Í"ø CARRIAGE BOLT - SAD FOR FINISH 1 TRACK PER S1.3 NOTE 1. INSULATION - SAD BOX HEADER 1Ï" x 'A' x 1Ï" x 54 MIL Z CLIP TYPICAL AT EA MOUNTING STRAP LSSU HGR, TYP STUD PER SCHEDULE (E) JOIST A 4" MAX 54 MIL BACKING PLATE W/ (2) #8 @ 12" TO STRUCTURE 12 RIDGE BEAM PER PLAN 1" ALUM MOUNTING STRAP #12 SMS - TYP - FIELD DRILL HOLES JOIST PER PLAN W/ JBA HGR CLOCK PANEL BEAM PER PLAN SECTION AT CLOCK MOUNTING STRAP ATTACHMENT 9 1 1/2" = 1'-0" 6 4x BEAM OR SOLID BLOCKING PER PLAN ALIGN W/ WALL ABOVE TRACK CONN TO CONCRETE AT STUD 3/4" = 1'-0" 3 PLAN AT RIDGE BEAM TO PIPE COLUMN 3/4" = 1'-0" FLAT TAIL SIDE CLIP (FTSC) @ 32" OC SECTION AT TOWER WALL BASE CONN AT ROOF FRAMING 3/4" = 1'-0" PROJECT TITLE: SUBSTRATE 1 1/2" = 1'-0" 600T150-43 3" MAX ALTERNATE CONFIGURATION L6x6xÍx1'-4" w/ TOS = (TOS @ BEAM) - Ë". 1Ï" MIN TYP MISCELLANEOUS DETAILS 4" MIN TYP PLAN AT CORNER OF STRUC FASCIA SHEET TITLE: 1" = 1'-0" 2 770 TAMALPAIS DR., INC., A FLORDIA CORPORATION RIDGE BEAM TO PIPE COLUMN OWNER: 5 100 CORTE MADERA TOWN CENTER, CORTE MADERA, CA 94925 (2) 16d EA CONTACT 1/4" = 1'-0" ADDRESS: 8 1/2" = 1'-0" TCCM TOWER RELOCATION ELEVATION AT CLOCK 11 CONT L4x4xË AROUND PERIMETER Ñ"ø MB - TYP 1'-0" TYP HSS PER PLAN 2'-0" TYP 4" STUD 3 S1.3 F VI 400S137-33 WEB STIFFENER W/ (8) #8 SMS TO HEADER - TYP ES AT ALL JAMB LOCATIONS P TY WALL STUD 600S162-43 @ 16" OC 3"x3"x33 MIL BENT £ W/ PDP @ 16"oc TO HSS ES HEADER FINISH - SAD __________ TYP Ë C8x11.5 CHANNEL BRACE EA CORNER w/ TOS = (TOS @ BEAM) - 2". BOLT TO FULL DEPTH STIFFENER £ PER TYP DETAILS. 7 1 FINISH ATTACHMENT AT HSS 1" = 1'-0" STOREFRONT 600T150-43 W/ 3Ï" SDS @ 16" PLAN CHECK 05/18/15 RESPONSE NO DESCRIPTION DATE REVISIONS 1'-0" HEADER L3x3xÊ AT MIDPOINT OF BEAM w/ TOS = (TOS @ BEAM) - Ë". L3"x3"x54 MIL x 6" BENT £ ES W/ (4) #8 SMS EA LEG - TYP (GAGE = 4") 8 __________ S7.1 (E) JOIST JAMB STUD (E) BEAM TRACK W/ #8 SMS @ 8" TO HEADER ABV 13 TYPICAL BEAM BRACING AT TOWER FRAME 3/4" = 1'-0" 10 ENLARGED ELEVATION AT JAMB TO HEADER CONN 1" = 1'-0" 4 SECTION AT BACKSIDE PARAPET WALL CONN 3/4" = 1'-0" DATE : PROJECT NO : DRAWN BY : CHECKED BY : COPYRIGHT : 2015.03.31 13529 NJR NJR 2015 RIM ARCHITECTS LLC DWG NO: S7.2 SHEET