Specifications
Cat. No
Tips/Racked tips (Autoclavable)
Volume Settings
Volume range (µl)
Increments(µl)
0.1 - 2
0.002
00-NPP-2
00-NPP-10
00-NPP-20
0.5 - 10
0.01
2 - 20
0.02
00-NPP-100
Digital
10 - 100
0.1
00-NPP-200
Setting
20 - 200
0.2
00-NPP-1000
100 - 1000
1
00-NPP-5000
1000 - 5000
10
00-NPP-10ML
1000 - 10000
10
Volume (µl)
Accuracy (%)
Precision (%)
0.2
±12.0
≦6.0
1
±5.0
≦2.5
2
±3.0
1
Cat. No
Volume range (µl)
00-BMT-UT
00-BMT-UTR
00-BMT-SS
00-BMT-SSR
Color
Length of tips (mm)
0.1 - 10
31.4
0.5 - 10
45.7
Q’ty
1000 (bag)
960 (96pcs.×10c /s)
1000 (bag)
NEW
960 (96pcs.×10c /s)
1000 (bag)
00-BMT-SG
2 - 200
Clear
53.0
960 (96pcs.×10c /s)
00-BMT-SGR
00-BMT-L
100 - 1000
77.0
1000 - 5000
132.0
1000 - 10000
158.0
00-BMT-LR
00-BMT-X
00-BMT-XR
00-BMT-Z
1000 (bag)
1000 (100pcs.×10c /s)
200 (bag)
100 (50pcs.×2c /s)
200 (bag)
Accuracy and Precision
Cat. No
00-NPP-2
00-NPP-10
00-NPP-20
00-NPP-100
Cat. No
Volume (µl)
Accuracy (%)
20
±1.0
≦0.5
100
±0.8
≦0.3
≦1.0
200
±0.8
≦0.2
±4.0
≦3.0
100
±1.0
≦0.5
5
±1.0
≦1.0
500
±0.8
≦0.3
10
±1.0
≦0.5
1000
±0.7
≦0.2
2
±5.0
≦3.0
1000
±1.0
≦0.3
10
±1.0
≦1.0
2500
±0.8
≦0.3
20
±1.0
≦0.4
5000
±0.6
≦0.2
10
±2.0
≦1.0
1000
±2.0
≦0.4
50
±1.0
≦0.3
5000
±0.8
≦0.3
100
±0.8
≦0.3
10000
±0.4
≦0.2
00-NPP-200
00-NPP-1000
00-NPP-5000
00-NPP-10ML
Precision (%)
The AC and CV above are measured with the disposable tips described in the catalogue.
The AC and CV at 0.2µl depend much on the sampling skill and the sampling condition where pipettes are used.
Accessories
[ Tube opener ]
[ Stand ]
Cat. No : 00-NTO
Q’ty : 3
Cat. No : 00-MLT-STD2
Capacity : 6
Cat. No : 00-BM-STD
Capacity : 6
Cat. No : 00-NLE-STD
Capacity : 1
Parts and Disposables
[ 2µl - 1000µl ]
Description
Plunger set
[ 5000µl, 10ml ]
Contents
Plunger
Plunger head
O-ring
Seal ring
Nozzle cylinder
Nozzle cylinder
O-ring &
Seal ring set
O-ring
Seal ring
Ejector pipe
Ejector setting screw set
Filter
2µl - 1000µl
Description
Plunger set
2µl - 1000µl
First spring
Nozzle cylinder set
Volume
Setting screw
Spring washer
Washer
10pcs
Nozzle filter remover
Adjustment Tool
Sizes of the parts depend on the volume range. Please check before ordering.
2µl - 20µl
Nozzle cylinder set
100µl - 1000µl
Nozzle cylinder O-ring
100µl - 1000µl
O-ring &
Seal ring set
2µl - 1000µl
Ejector pipe
Contents
Plunger
Joint block (with O-ring)
Joint plate
Joint shaft
Nozzle cylinder
O-ring
10ml
5000µl , 10ml
5000µl , 10ml
5000µl , 10ml
3pcs
Ejector setting screw set
4pcs
1000µl
Filter
100pcs
1000µl
Nozzle filter remover
2µl - 10ml
5000µl
5000µl , 10ml
O-ring
Seal ring
Ejector setting screw set
2µl - 1000µl
Volume
Adjustment Tool
5000µl
10ml
5000µl , 10ml
5000µl , 10ml
2µl - 10ml
Debut Campaign
Sizes of the parts depend on the volume range. Please check before ordering.
5-year warranty
Distributor
2, Kandamikura-cho, Chiyoda-ku, Tokyo, 101-0038, Japan
Te l : +81-3-6661-2602
Fax : +81-3-6661-2604
E-mail : [email protected]
URL: www.nichiryo.co.jp
090803A
Innovation in Durability, Strength, Stability, and Comfort
New micro pipette
from Nichiryo
NICHIRYO’S accumulated technology through
the years has reached the next level of innovation
for an all new pipette. Nichiryo introduces
the state of the art “Nichipet Premium”.
Based on a long quest for the ideal pipette component, function and design Nichiryo now launches
the professional model “Nichipet Premium”.
MADE IN
JAPAN
Innovation in “Durability” and “Strength” – That’s “Premium”
Nichipet premium carries new technology for materials used in the internal components and outer body.
Nichipet Premium strengthens its durability and prolongs life in tough laboratory conditions.
Improved abrasion tolerance
“Long Life”.
Debut Campaign
Improved Durability
“Tough Body”.
Seal ring of the Premium is tested
dispensing / aspirating 600,000 times.
Non-greased plunger makes it easy to
maintain. ( 2µl – 1000µl )
5-year warranty
New material used
for 4 notches- lock
improves its strength,
which minimizes
the lever shifting from
the original position.
The test was conducted by Nichiryo.The test result may vary with condition of usage.
Tested
600,000
Nozzle top is highly abrasion tolerant.
Materials used for
pipette body have
high tolerance to
solvents and
to drop impact.
Hyper Blower System, longer second-push stroke, improves dispensing efficiency. ( 2µl, 10µl, 20µl )
Easy-Calibration function provides for simple in lab calibration.
Single hand pipetting can be done smoothly to improve operation efficiency.
Renewed internal construction improves accuracy and reproducibility.
Hand temperature doesn’t permeate through the body of the pipette. Therefore the accuracy of the volume measurement is not affected. ( Patented )
Slim nozzle can be easily inserted into tubes to aspirate.
All components are manufactured and assembled in Japan to ensure the quality and reliability of the pipette.
How we can relieve fatigue and improve comfort from pipette operations . . . That is what we are looking for all the time.
The premium provides high efficiency to relieve fatigue and stress from many repetitive operations.
New round form of the Premium
mitigates fatigue and stress from
heavy workload.
( 2µl – 1000µl )
ceramic plunger
Innovation in “Stability” and “Preciseness” – That’s “Premium”.
While maintaining a number of positive aspects of the Nichipet EX, the Nichipet Premium upgrades internal functionality in order to sustain better accuracy and
reproducibility. In addition, handling comfort supports fast and smooth liquid handling for researchers.
Innovation in “Fatigue-Free” and “Comfort” – That’s “Premium”.
times
Seal ring
UV
Resistance
Non corrosive ceramic
used in the plunger
( 100µl – 10ml )
The 5-year warranty can be applied for all of Nichipet Premiums until purchase of June 30, 2010.
The 5-year warranty can be valid for Nichipet Premiums registered by a 5-year warrantee registration form attached with items.
The 5-year warranty does not cover defects caused by excessive wear and tear or damage due to shipping, accident, abuse, misuse, or usage not in accordance with instructions manual, or damage caused by liquid permeation in the nozzle corn.
Enlarged push button is
easy to depress.
The body ditch prevents pipette
from slipping.
What’s new!
Shortened to release
tension to your thumb.
Shortened
the distance to
operate smoothly
Enlarged easy to read
counter display for
volume setting.