Vent-A-Hood specifications sheet

Transcription

Vent-A-Hood specifications sheet
SPECIFICATION
SHEETS
SUBJECT TO CHANGE WITHOUT NOTICE
UNDER
CABINET
SUBJECT TO CHANGE WITHOUT NOTICE
UNDER CABINET RANGE HOOD SPECIFICATIONS


PRH6-K Halogen lights only. This model not available with heat lamps. This model only available in
Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available.
 

The VP521 transition is available
for top vent applications
at an additional charge.
7”
7 ½”








10”
Connection Diagrams (24”, 30", 36", & 42" Widths)


 

”
3¼
Recommended
Mounting Height*
 
 
Electrical
 
 





 

 
 
 
 
Electrical



*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
K250 (Top Vent)
K250 (Back Vent)
Volts
Amps
Hz
RPM
115
115
3.2
3.2
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
250
375
223
220
190
220
330
215
195
180
Minimum Round
Duct Size
7" (38 in.2)
7" (38 in.2)
Sones#
7.4
7.4
All K-Series hoods have two halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A
C
UL
R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS


SLH6-K Halogen lights only. This model not available with heat lamps. This model only available in
Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available.

The VP521 transition is available
for top vent applications
at an additional charge.
7”
7 ½”








10”
Connection Diagrams (24”, 30", 36", & 42" Widths)


 

”
3¼
Recommended
Mounting Height*
 
 
Electrical
 
 





 

 
 
 
 
Electrical



*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
K250 (Top Vent)
K250 (Back Vent)
Volts
Amps
Hz
RPM
115
115
3.2
3.2
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
250
375
223
220
190
220
330
215
195
180
Minimum Round
Duct Size
7" (38 in.2)
7" (38 in.2)
Sones#
7.4
7.4
All K-Series hoods have two halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A
C
UL
R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS
NP9/NPH9/PR9/PRH9/SL9/SLH9 “H” in part number indicates halogen lighting. WL-1 warming lights
are available on selected models.
12”
12”
9”
4”
WID
TH
12”
9”
2”
WID
TH
”
21
NP9/NPH9
9”
2”
WID
TH
”
21
PR9/PRH9
SL9/SLH9
Connection Diagram (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
Electrical
3 ¼”
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48" Widths)
10” Round
7 �⁄��”
5 ½”
Wall Side
Cabinets
Centerline
of Hood
Centerline
of Hood
7 �⁄��”
”
21
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” Width)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS
F/XR9/XRH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on
selected models.
12”
12”
9”
”
2¼
WID
TH
9”
”
2¼
¾” O
ffse
t
WID
TH
”
21
F (Fluorescent Lights Only)
XR9/XRH9
Connection Diagram (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
Electrical
3 ¼”
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48" Widths)
10” Round
7 �⁄��”
5 ½”
Wall Side
Cabinets
Centerline
of Hood
Centerline
of Hood
7 �⁄��”
”
21
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” Width)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. The F hood is available with fluorescent lights only (one per single or dual blower) and the XR9/XRH9 is available with fluorescent light (one for each single or dual blower) or with halogen
lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS
SL6/SLH6 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected
models.
”
12
2”
6”
9”
WID
TH
6”
19
½”
SL6/SLH6
Connection Diagram (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
Electrical
3 ¼”
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42” - 48" Widths)
10” Round
7 �⁄��”
5 ½”
6”
8’ Ceiling
300 CFM B100 Single Blower
Wall Side
Cabinets
Centerline
of Hood
Centerline
of Hood
7 �⁄��”
9”
Sloped
Bottom
21”-24”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” Width)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
WALL
MOUNT
SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT RANGE HOOD SPECIFICATIONS
NP18/NPH18/NPX18/NPXH18/PR18/PRH18/PRX18/PRXH18/SL18/SLH18/SLX18/SLXH18
“H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models
(included on NP Series). X in part number indicates 27” depth.
12”
12”
12”
18”
18”
18”
6”
4”
4”
4”
- 2 7”
NP X - 2
P
N
WID
TH
4”
- 2 7”
PR X - 2
R
P
WID
TH
NP(X)18/NP(X)H18
(Includes WBAR warming light bar)
PR(X)18/PR(X)H18
SL(X)18/SL(X)H18
Connection Diagrams (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
6” Outlet
3 ¼”
Recommended
Mounting Height*
5 ¼”
Optional
Duct Cover
Vent
Holes
1 ¾”
Electrical
8” Outlet
Electrical
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 60" Widths)
10” Round
7 �⁄��”
5 ½”
Wall Side
18”
Centerline
of Hood
Centerline
of Hood
7 �⁄��”
4”
- 2 7”
SL X - 2
L
S
WID
TH
30”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
*Exceeding recommended
mounting height may
compromise performance.
10” OR 12”
Round
Connection Diagram (48” - 66" Widths)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
VP562/VP563
transition
centers outlet
over top of hood
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
DA18/DAH18/PWV18/PWVH18/XR18/XRH18/XRX18/XRXH18 “H” in part number indicates halogen
lighting. WBAR warming light bar is available on selected models. X in part number indicates 27"
depth.
12”
12”
12”
18”
3”
18”
3”
1½
” Off
set
WID
TH
18”
” Off
set
WID
TH
”
24
1” O
4”
1½
WID
TH
”
24
DA18/DAH18
PWV18/PWVH18
Connection Diagrams (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
Electrical
3 ¼”
4”
- 2 7”
XR X - 2
XR
XR(X)18/XR(X)H18
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
6” Outlet
ffse
t
8” Outlet
Electrical
Centerline
of Hood
Centerline
of Hood
300 CFM B100 Single Blower
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42” - 60" Widths)
7 �⁄��”
5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” - 66" Widths)
11”
11”
5 ½”
12” Round
5 ½”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Vent
Holes
1 ¾”
*Exceeding recommended
mounting height may
compromise performance.
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
CX30/CXH30/DA30/DAH30/PWV30/PWVH30/SL30/SLH30 “H” in part number indicates halogen
lighting. WBAR warming light bar is available on selected models.
12”
12”
30”
3”
30”
3”
1½
” Off
set
WID
TH
12”
12”
CX30/CXH30
” Off
set
4”
1½
3”
1½
WID
TH
”
24
30”
30”
” Off
set
WID
TH
”
24
DA30/DAH30
WID
TH
”
24
PWV30/PWVH30
SL30/SLH30
Connection Diagrams (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
Electrical
3 ¼”
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
6” Outlet
”
24
30”
8” Outlet
Electrical
Centerline
of Hood
Centerline
of Hood
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
30”
Connection Diagram (42” - 60" Widths)
7 �⁄��”
5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” - 66" Widths)
11”
11”
5 ½”
12” Round
5 ½”
Wall Side
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
VP562/VP563
transition
centers outlet
over top of hood
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
CW/CWH “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected
models.
12”
WI
DT
H
24”
CW/CWH
Connection Diagrams (30” - 48” Widths)
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
5 ¼”
1 ¾”
Electrical
6” Outlet
3 ¼”
Cabinets
of Soffit
Vent
Holes
8” Outlet
Electrical
12”
Centerline
of Hood
Centerline
of Hood
300 CFM B100 Single Blower
600 CFM Dual Blower
(Top View)
(Top View)
8’ Ceiling
5 ¼”
Recommended
Mounting Height*
30”
Connection Diagram (42” - 60" Widths)
7 �⁄��”
5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” - 66" Widths)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
VP562/VP563
transition
centers outlet
over top of hood
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
TLH (Halogen Lights) Not available with heat lamps.
TILT (Fluorescent Light) Not available with heat lamps.
Cut Out For
Top Vent
Cut Out For
Back Vent
Door Panel Must Be
Supplied By Cabinet Maker
Hinge 1” From Top
H
DT
WI
24 ¼”
Door Panel Can
Overhang
24 ¼”
11
21 Bevel Minimum1 ¼” Long
¼” Or Less
o
Mounting Holes
For Door Panel
¼”
8¼
Door Panel Specifications
TLH/TILT
”
Recommended
Mounting Height*
Connection Diagrams (30” - 48” Widths)
5 ¼”
1 ¾”
1 3⁄8”
Wall Side
5 ½”
Wall Side
Vent
Hole
5 ¼”
1 ¾”
Electrical
6” Outlet
3 ¼”
Cabinets
or Soffit
Vent
Holes
8” Outlet
Electrical
24 ¼”
Centerline
of Hood
Centerline
of Hood
600 CFM B200 Dual Blower
(Top View)
(Top View)
Channel For Mounting Strip
36”
13 ½”
13 ½”
23 ¾”
10 ¾”
24 ¼”
24 ¼”
10 ¾”
12 ½”
Cut Out For
Back Vent
8’ Ceiling
300 CFM B100 Single Blower
11 ¼”
Left End
Back View of Hood
*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
Volts
Amps
Hz
RPM
115
115
1.5
2.9
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
300
450
273
245
225
600
900
531
480
430
Minimum Round
Duct Size
6" (28 in.2)
8" (50 in.2)
Sones#
5.4
6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0409A
C
UL
R
US
EURO-STYLE
WALL
MOUNT
SUBJECT TO CHANGE WITHOUT NOTICE
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
PD14/PDH14/SLD14/SLDH14 “H” in part number indicates halogen lighting. These models not available
with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in
standard and custom sizes.
10”
10”
OPTIONAL
DUCT
COVER
HEIGHT
OPTIONAL
DUCT
COVER
10”
8”
2 5⁄
HEIGHT
10”
3”
14”
14”
WID
TH
WID
TH
”
21
”
21
PD14/PDH14
SLD14/SLDH14
30” model is limited to B100 single blower only
Connection Diagram (30" - 48" Widths)
1 ¾”
1 7⁄8”
Wall Side
Recommended
Mounting Height
Blower
Exhaust
Outlet
Vent
Hole
6" Round
14"
Electrical
5 ¼”
6" Outlet
Optional Duct
Cover or Soffit
5"
14”
Centerline
Of Hood
(Front View)
8’ Ceiling
300 CFM B100 Single Blower
(Top View)
24”
Connection Diagram (36”- 48” Widths)
5 ½”
Wall Side
5 ¼”
Blower
Exhaust
Outlet
1 ¾”
36”
8" Round
Vent
Holes
5"
14"
8” Outlet
Electrical
Centerline
of Hood
(Front View)
600 CFM B200 Dual Blower
*Exceeding recommended
mounting height may
compromise performance.
(Top View)
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
Volts
Amps*
Hz
RPM
115
115
1.5
2.9
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
300
450
273
245
225
600
900
531
480
430
Minimum Round
Duct Size
6" (28 in.2)
8" (50 in.2)
Sones#
5.4
6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
EP(X)18/EP(X)H18/NEP(X)18/NEP(X)H18/SEP(X)18/SEP(X)H18 “H” in part number indicates halogen
lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately).
Optional duct covers available in standard and custom sizes.
12”
12”
OPTIONAL
DUCT
COVER
HEIGHT
OPTIONAL
DUCT
COVER
18”
4”
WID
TH
12”
OPTIONAL
DUCT
COVER
18”
4”
WID
TH
4”
- 2 7”
EP X - 2
P
E
EP(X)18/EP(X)H18
12”
HEIGHT
12”
HEIGHT
12”
18”
3”
WID
TH
”
24 ”
P - - 27
E
N PX
NE
NEP(X)18/NEP(X)H18
”
24 ”
P - 27
SE PX SE
SEP(X)18/SEP(X)H18
(X) in part number indicates 27” depth
Connection Diagram (36" - 48" Widths)
5 ½”
Wall Side
Recommended
Mounting Height*
5 ¼”
Optional
Duct Cover
Vent
Holes
1 ¾”
18”
8” Outlet
Electrical
8’ Ceiling
Centerline
of Hood
600 CFM B200 Dual Blower
(Top View)
30”
Blower
Exhaust
Outlet
9"
8" Round
36”
18"
*Exceeding recommended
mounting height may
compromise performance.
(Front View)
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
600
900
531
480
430
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
EP(X)T18/EP(X)TH18/NEP(X)T18/NEP(X)TH18/SEP(X)T18/SEP(X)TH18 “H” in part number indicates
halogen lighting. These models not available with heat lamps. Shown with optional duct cover sold
separately). Optional duct covers available in standard and custom sizes.
HEIGHT
18”
4”
WID
TH
14”
26”
OPTIONAL
DUCT
COVER
18”
4”
WID
TH
”
24 ”
T - 27
EP XT EP
EP(X)T18/EP(X)TH18
26”
OPTIONAL
DUCT
COVER
HEIGHT
14”
26”
HEIGHT
14”
OPTIONAL
DUCT
COVER
18”
3”
WID
TH
4”
- 2 7”
PT - 2
NE PXT
NE
NEP(X)T18/NEP(X)TH18
4”
- 2 7”
PT - 2
SE PXT
SE
SEP(X)T18/SEP(X)TH18
(X) in part number indicates 27” depth
Connection Diagram (42" - 66" Widths)
Recommended
Mounting Height
10"
12 �⁄�”
9 �⁄�”
Wall Side
1 ¾”
Optional
Duct Cover
8 ½”
Electrical (2)
18”
18"
10" Outlet
Centered On
Hood Top
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Standard Transition
Installed (Front View)
Connection Diagram (54” - 66” Widths)
8’ Ceiling
Centerline
Of Hood
30”
12"
1 ¾”
16 ½”
5 ½”
7 ½"
Wall Side
7"
1 ¾”
Electrical (2)
12" Outlet
Centered On
Top Of Hood
18"
36”
Centerline
Of Hood
1200 CFM Double B200 Dual Blowers
VP563 Standard Transition
Installed (Front View)
(Top View)
The transition shown (VP562 &
VP563) is installed in the hood
at the factory as a standard
item. It will be located in the
exact center of the duct cover
(left to right & front to rear).
Duct Cover
(Top of Hood)
*Exceeding recommended
mounting height may
compromise performance.
10" Dia. or 12" Dia.
Transition Location
"Centered"
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
4.4
5.8
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
900
1350
804
725
655
1200
1800
1062
960
860
Minimum Round
Duct Size
10" (79 in.2)
12" (113 in.2)
Sones#
6.3
6.6
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one for each single or dual blower) or with halogen lights (3 lights: 42" - 53", 4 lights: 54" - 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
CONTEMPORARY
WALL
MOUNT
SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT RANGE HOOD SPECIFICATIONS
The VP521 transition is available
for top vent applications
at an additional charge.




CWEH6-K Equipped with halogen lighting. This model not available with heat lamps. Shown with optional
duct cover (sold separately). Optional duct covers available in standard and custom sizes. Available in
painted and stainless steel finishes. Available in 30", 36", 42", and 48" widths only.

OPTIONAL
DUCT
COVER
7”
7 ½”



”




10”
CWEH6-K
Connection Diagram
Recommended
Mounting Height*
 

 
3¼





(Top View)



*Exceeding recommended
mounting height may
compromise performance.
(Front View)
Electrical/Mechanical Specifications For Blower Units
Model
K250 (Top Vent)
Volts
Amps*
Hz
RPM
115
2.2
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
250
375
223
220
190
Minimum Round
Duct Size
7" (38 in.2)
Sones#
7.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" & 36", 3 lights: 42" & 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
GTH Equipped with halogen lighting. These models not available with heat lamps. Only available in
stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in
standard and custom sizes. Pot rail included.
”
12
The VP521 transition is available
for top vent applications
at an additional charge.
OPTIONAL
DUCT
COVER
7”
12
”
10”
”
½
16
7 ½”
16
”
1 ¾”
”
36
21
”
”
10”
GTH (36” Width Only)
3¼
Connection Diagram
1”
Recommended
Mounting Height*
3 ¼” x 10”
Outlet
Wall Side
Optional
Duct Cover
4 ½”
10”
Centerline
of Hood
8’ Ceiling
Electrical
24”
(Top View)
Outlet
36”
*Exceeding recommended
mounting height may
compromise performance.
6"
NOTE: DUCT COVER EXTENDS 4”
INTO TOP OF HOOD.
(Front View)
Electrical/Mechanical Specifications For Blower Units
Model
K250 (Top Vent)
Volts
Amps
Hz
RPM
115
3.2
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
250
375
223
220
190
Minimum Round
Duct Size
7" (38 in.2)
Sones#
7.4
All K-Series hoods have two halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS


Space Between
Duct Covers


OPTIONAL
DUCT
COVERS




OPTIONAL
DUCT
COVER





CWEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional
duct cover(s) (sold separately). Optional duct covers are available in standard and custom sizes.






Width A
4"
CWEH9-348
8"
CWEH9-354
10"
CWEH9-360
12"
CWEH9-448
10"
CWEH9-454
10"
CWEH9-460
12"
CWEH9-466
14"







Model
CWEH9-342







Connection Diagram (30”- 48” Widths) Connection Diagram (30”- 54” Widths)
 

 

 
 
Recommended
Mounting Height*
 

Motor   
Cooling
Vent
Electrical
Electrical
6" Round


Motor
Cooling
Vent


8" Round
300 CFM B100 Single Blower
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42”- 60” Widths)

 
 


 
Model
 
 
 
Motor
Cooling
Vent


8" Round

6" Round
900 CFM B200 Dual & B100 Single Blower
(Top View)
Width A
Width B
CWEH9-342
8"
8"
CWEH9-348
10"
10"
CWEH9-354
11"
11"
CWEH9-360
12"
12"
Outlet Spacing for
900 CFM Models
Connection Diagram (48”- 66” Widths)

 


 
 
 
Electrical (2)
Motor
Cooling
Vent


8" Round
8" Round
Model
Width A
Width B
CWEH9-448
11"
11"
CWEH9-454
11"
11"
CWEH9-460
12"
12"
CWEH9-466
13"
13"
*Exceeding recommended
mounting height may
compromise performance.
1200 CFM Double B200 Dual Blowers
Outlet Spacing for
1200 CFM Models
Electrical/Mechanical Specifications For Blower Units
(Top View)
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
CWLH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with
optional duct cover (sold separately). Optional duct covers are available in standard and custom sizes
s
(sold separately). Galley rail included.
od
Ho ds
o
FM Ho
0C M
90 00CF
r
fo 12
ide or
”W e f
26 “ Wid
34
12
”
12
”
OPTIONAL
DUCT
COVER
4 ½”
12
”
4 ½”
OPTIONAL
DUCT
COVER
4 ½”
4 ½”
”
5¾
hs
idt
8” Widths
4
&
2”, ” W
”, 4 48
36 2”, &
,
”
4
0
- 3 6”,
FM - 3
0 C 0CFM
0
3 60
9”
21
”
3”
hs
idt s
” W idth
0
& 6 66” W
4”,
-5 ,&
M - 60”
F
0C M
90 00CF
12
”
5¾
9”
21
”
3”
Recommended
Connection Diagram (30”- 48” Widths) Connection Diagram (36”- 48” Widths) Mounting Height*
1 ¾”
5 ¼”
½”
1 ¾”
Wall Side
4 ½”
Wall Side
5 ¼”
Vent
Hole
Vent Holes
Electrical
1 ½”
6” Outlet
Optional
Duct Cover
5 ¼”
Centerline
of Hood
Centerline
of Hood
8”
Outlet
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (54”- 60” Widths)
7 �⁄��”
1 ¾”
1 �⁄�”
10” Round
Vent
Holes
10” Round
17 ½”
36”
Electrical (2)
5 ¼”
6" Outlet
Centerline
of Hood
8" Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower VP562 Transition (Optional) for B300
(B200 Dual & B100 Single Blower)
(Top View)
11”
12” Round
11”
5 ½”
5 ½”
12” Round
Wall Side
Vent
Holes
1 ¾”
16 ½”
8" Outlet
5 ¼”
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) for B400
(For Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
*Exceeding recommended
mounting height may
compromise performance.
10” OR 12”
Round
Connection Diagram (60”- 66” Widths)
8" Outlet
27”
7 �⁄��”
5 ½”
Wall Side
9”
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
VP562/VP563 transition
centers outlet over
top of hood
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
XLH12 Equipped with halogen lighting. This model not available with heat lamps. Only available
in stainless steel. Optional duct covers/finished duct available in standard and custom sizes (sold
separately).
”
10
HOOD WITH
OPTIONAL ROUND
DUCT COLLARS AND
FINISHED ROUND
DUCT
DUCT COVERS/FINISHED
ROUND DUCT AND DUCT
COLLARS PRICED SEPARATELY
10
”
1”
HOOD WITH OPTIONAL
10” X 10” DUCT COVER
12”
2”
15”
”
30
21
”
HOOD WITH
OPTIONAL
SQUARE DUCT
COLLARS
AND FINISHED
ROUND DUCT
”
6
&3
2” LIP MAY BE BRASS, COPPER,
STAINLESS STEEL, OR MIRROR
STAINLESS STEEL
XLH12
Connection Diagram (30” & 36” Widths)
1 ¾”
4 ½”
Wall Side
Blower
Exhaust
Outlet
5 ¼”
Recommended
Mounting Height*
8" Round
Vent Holes
5 ¼”
12"
8” Outlet
Electrical
Optional
Finished
Duct Pipe
3"
Centerline
of Hood
12”
(Front View)
NOTE: WHEN PRICING CUSTOM FINISHED ROUND DUCT, INCLUDE THE 3”
FINISHED ROUND
THAT EXTENDS INTO TOP OF HOOD AND 1” THAT EXTENDS INTO CEILING (4”
DUCT (REQUIRES TWO TOTAL.) TOTAL OVERALL HEIGHT CANNOT EXCEED 60” (10’ 8” CEILING).
DUCT COLLARS)
ROUND DUCT COLLAR SQUARE DUCT COLLAR
Crimped
Galvanized
Connector
3”
1” Into Ceiling
10
12” For 7’ Ceiling
24” For 8’ Ceiling
36” For 9’ Ceiling
Overall Height
Of Finished
Round Duct
24”
3”
”
10
10
”
8’ Ceiling
(Top View)
”
”
10
36”
10” x 10” SQUARE DUCT COVER
3” Into Hood
10”
10”
HEIGHT
8” ROUND
NOTE: TOP END OF FINISHED
ROUND DUCT IS CRIMPED TO ALLOW
FOR DUCT CONNECTION IN THE
CEILING (CRIMP IS NOT INCLUDED
IN THE OVERALL HEIGHT OF THE
FINISHED ROUND DUCT).
CUSTOM SIZES
ALSO AVAILABLE
*Exceeding recommended
mounting height may
compromise performance.
NOTE: DUCT PIPE EXTENDS 3”
INTO TOP OF HOOD AND 1” INTO
CEILING.
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual
Volts
Amps
Hz
RPM
115
3.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
600
900
531
480
430
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.5
Hood has two halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
ZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in
stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in
standard and custom sizes (sold separately). Fixed pot rails included.
OPTIONAL
”
12
”
12
OPTIONAL
DUCT
COVER
”
12
OPTIONAL
DUCT
COVER
12
12
12
”
”
”
”
18
”
1”
”
”
18
”
34
16
”
1”
14 3⁄8”
”
36
24
”
”
1”
14 �⁄�”
DUCT
COVER
12
16
”
16
”
18
16
”
28
OPTIONAL
DUCT
COVER
14 �⁄�”
”
42
24
1”
”
48
24
”
”
54
14 3⁄8”
”
24
”
ZTH
Connection Diagram (36”- 48” Widths)
1 ¾”
4 ½”
Wall Side
5 ¼”
Blower
Exhaust
Outlet
Vent
Holes
5 ¼”
Recommended
Mounting Height*
8” Round
Optional
Duct Cover
14 �⁄�”
8” Outlet
Electrical
14 �⁄�”
9”
Centerline
of Hood
(Front View)
600 CFM B200 Dual Blower
8’ Ceiling
(Top View)
Connection Diagram (54” Width)
10” Round
Wall Side
6 �⁄��"
8 �⁄��"
4 ½"
1 �⁄�"
30”
10” Round
1 ¾"
36”
17 ½”
Vent
Holes
Electrical (2)
5 ¼"
6" Outlet
Centerline
Of Hood
8" Outlet
8” Round
900 CFM B200 Dual Blower
& B100 Single Blower
8” Round
6” Round
VP562 Transition (Optional) For B300
For B200 Dual and B100 Single Blower
(Top View)
Blower
Exhaust
Outlets
8” Round
2”
*Exceeding recommended
mounting height may
compromise performance.
NOTE:DUCT COVER EXTENDS
5 3/8” INTO TOP OF HOOD.
10”ROUND
OR 12”
10”
Round
6” Round
14 �⁄�”
9”
VP562 transition
centers outlet over
top of hood
(Front View)
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual
B200 Dual & B100 Single
Volts
Amps
Hz
RPM
115
115
4.9
6.4
60
60
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
600
900
531
480
430
8" (50 in.2)
900
1350
804
725
655
VP562: 10" (79 in.2)
Sones#
6.5
6.3
Hood has four halogen lights (one light in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
RETRO
STYLE
SUBJECT TO CHANGE WITHOUT NOTICE
RETRO STYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
AH12 Halogen lights only. This model is not available with heat lamps. Painted round duct and ceiling
collar are priced separately.
15”
16”
4”
12”
WID
TH
Includes side wing
panels and splash
panel. Splash panel is
30” tall x hood width.
12”
”
27
2” x 2”
Clipped
Corners
AH12
Recommended
Mounting Height*
Connection Diagram (30”- 48” Widths)
30” Model is Limited to B100 Single Blower Only
Blower
Exhaust
Outlet
1 ¾”
1 7⁄8”
Wall Side
Optional
Painted
Round Duct
6" Round
Vent
Hole
2"
Electrical
5 ¼”
6" Outlet
12”
12"
Centerline
Of Hood
(Front View)
300 CFM B100 Single Blower
8’ Ceiling
(Top View)
Connection Diagram (36”- 48” Widths)
5 ½”
Wall Side
Blower
Exhaust
Outlet
5 ¼”
8" Round
Vent
Holes
1 ¾”
2"
36”
8” Outlet
Electrical
33”
12"
Centerline
of Hood
(Front View)
*Exceeding recommended
mounting height may
compromise performance.
Optional Ceiling Collars
NOTE: DUCT PIPE EXTENDS 2”
INTO TOP OF HOOD AND 1” INTO
CEILING.
600 CFM B200 Dual Blower
(Top View)
Optional Painted Round Duct
Crimped
Galvanized
Connector
1” Into Ceiling
11”
3” For 7’ Ceiling
15” For 8’ Ceiling
27” For 9’ Ceiling
Overall Height
Of Finished
Round Duct
6 ¼” Diameter
Opening
ARC6
2” Into Hood
11”
8 1/4” Diameter
Opening
ARC8
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
Volts
Amps*
Hz
RPM
115
115
1.5
2.9
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
300
450
273
245
225
600
900
531
480
430
Minimum Round
Duct Size
6" (28 in.2)
8" (50 in.2)
Sones#
5.4
6.5
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A
C
UL
R
US
RETRO STYLE UNDER CABINET RANGEHOOD SPECIFICATIONS
CLH9 Halogen lights only.
12”
9”
2”
½” Offset
WID
TH
”
21
CLH9
Connection Diagram (30” - 48” Widths)
5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent
Hole
5 ¼”
Vent
Holes
1 ¾”
Electrical
6” Outlet
3 ¼”
Recommended
Mounting Height*
Soffit
8” Outlet
Electrical
Cabinets
Centerline
of Hood
Centerline
of Hood
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48” Widths)
7 �⁄��”
5 ½”
Wall Side
10” Round
7 �⁄��”
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
10” OR 12”
Round
Connection Diagram (48” Width)
11”
11”
5 ½”
12” Round
5 ½”
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Wall Side
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
115
1.5
2.9
4.4
5.8
60
60
60
60
1550
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
5.4
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
ISLAND
SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND RANGE HOOD SPECIFICATIONS
ISF18/ISFH18/ISL18/ISLH18/IXR18/IXRH18 “H” in part number indicates halogen lighting. These
models not available with heat lamps.
12
Bo ” Les
tto s T
m W han
idt
h
”
15
12
Bo ” Les
tto s T
m W han
idt
h
”
15
18”
18”
3”
1½
”O
WI
3”
ffse
t
DT
H
12
Bo ” Les
tto s T
m W han
idt
h
”
15
”
27
WI
DT
H
ISF18/ISFH18
ISL18/ISLH18
18”
4”
1” O
ffse
t
WI
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
”
27
DT
H
”
27
IXR18/IXRH18
Connection Diagram (36” - 54”)
Connection Diagram (60” - 66”)
Centerline
of Hood
¾”
2 �⁄�”
5” x 16”
Exhaust
Opening
Electrical (2)
Vent Holes
Vent Holes
¾”
8" Transition
Opening (2)
9" Above Top
Of Hood
Centerline
Of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
30”
36”
9"
8" Round
Optional
Duct Cover
5" x 16"
Exhaust
Opening (2)
18”
8” Transition
Opening 9”
Above Top
of Hood
Electrical
2 �⁄�”
Centerline
Of Hood
11"
8’ Ceiling
Centerline
of Hood
11"
Recommended
Mounting Height*
8" Round
9"
18"
5"
*Exceeding recommended
mounting height may
compromise performance.
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
PL18/PLH18/PLX18/PLXH18/PY18/PYH18 “H” in part number indicates halogen lighting. These models
not available with heat lamps.
12”
12
Bo ” Les
tto s T
m W han
idt
h
”
15
18”
18”
6”
3”
WI
DT
H
WI
1 ½”
Connection Diagram (36” - 54”)
2 �⁄�”
11"
2 �⁄�”
Centerline
Of Hood
8” Transition
Opening 9”
Above Top
of Hood
Electrical
1 ½”
�⁄��” Dia.
Island Duct Cover
Mounting Holes
(Top View)
”
27
PY18/PYH18
Connection Diagram (60” - 66”)
Centerline
of Hood
5” x 16”
Exhaust
Opening
ffse
t
DT
H
“X” in model number indicates 30” depth
¾”
”O
7”
-2 ”
PL - 30
X
PL
PL(X)18/PL(X)H18
Centerline
of Hood
1½
Electrical (2)
Vent Holes
Vent Holes
11"
Optional
Duct Cover
5" x 16"
Exhaust
Opening (2)
¾”
18”
8" Transition
Opening (2)
9" Above Top
Of Hood
Centerline
Of Hood
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
8’ Ceiling
550 CFM T200 Dual Blower
9"
8" Round
Recommended
Mounting Height*
30”
36”
8" Round
9"
18"
5"
*Exceeding recommended
mounting height may
compromise performance.
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
ICX30/ICXH30/ISF30/ISFH30 “H” in part number indicates halogen lighting. These models not available
with heat lamps.
12
Bo ” Les
tto s T
m W han
idt
h
”
15
12
Bo ” Les
tto s T
m W han
idt
h
”
15
30”
30”
1½
”O
WI
3”
DT
H
”O
WI
2
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
Connection Diagram (36” - 54”)
11”
5" x 16"
Exhaust
Opening
Vent Holes
7 ¾"
”
27
ISF30/ISFH30
Connection Diagram (60” - 66”)
Centerline
Of Hood
Centerline
Of Hood
ffse
t
DT
H
7”
ICX30/ICXH30
Electrical
1½
ffse
t
11”
5” x 16”
Exhaust
Opening (s)
Centerline
of Hood
8" Transition
Opening 3”
Below Top
of Hood
Vent Holes
30”
8” Transition
Opening (2)
3” Below Top
of Hood
7 ¼”
Electrical (2)
Centerline
of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
3"
8" Round
Recommended
Mounting Height*
8’ Ceiling
3”
30”
36”
8" Round
30"
*Exceeding recommended
mounting height may
compromise performance.
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
ISL30/ISLH30/PY30/PYH30 “H” in part number indicates halogen lighting. These models not available
with heat lamps.
12
Bo ” Les
tto s T
m W han
idt
h
”
15
12
Bo ” Les
tto s T
m W han
idt
h
”
15
30”
30”
3”
3”
DT
H
DT
H
”
27
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
Connection Diagram (36” - 54”)
Centerline
Of Hood
Vent Holes
7 ¾"
”
27
PY30/PYH30
Connection Diagram (60” - 66”)
Centerline
Of Hood
11”
5" x 16"
Exhaust
Opening
ffse
t
WI
ISL30/ISLH30
Electrical
”O
11”
8” Transition
Opening (2)
3” Below Top
of Hood
7 ¼”
Vent Holes
Electrical (2)
Centerline
of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
30”
36”
3"
8" Round
30”
5” x 16”
Exhaust
Opening (s)
Centerline
of Hood
8" Transition
Opening 3”
Below Top
of Hood
Recommended
Mounting Height*
8’ Ceiling
WI
1½
8" Round
30"
*Exceeding recommended
mounting height may
compromise performance.
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
CO/COH “H” in part number indicates halogen lighting. This model not available with heat lamps.
Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom
sizes.
”
20”
14
OPTIONAL
DUCT
COVER
”
14
2 OPTIONAL
DUCT
COVERS
20”
3”
3”
12”
WI
1½
”O
DT
H
1½
WI
ffse
t
DT
H
”O
ffse
t
12”
”
27
1 ½”
”
1 ½”
5⁄16” Dia.
27
CO/COH
Island Duct Cover
Mounting Holes
(Top View)
Connection Diagram (36” - 54”)
Connection Diagram (60” - 66”)
Recommended
Mounting Height*
Centerline
of Hood
11”
Centerline
of Hood
¾”
2 �⁄�”
5” x 16”
Exhaust
Opening
Centerline
of Hood
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Vent Holes
11”
¾”
Electrical (2)
Vent Holes
Optional
Duct Cover
5” x 16”
Exhaust
Opening (2)
8” Transition
Opening (2)
9” Above Top
of Hood
2 �⁄�”
12”
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
8’ Ceiling
Centerline
of Hood
30”
9"
8" Round
8" Round
36”
9"
12"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL
R
US
EURO-STYLE
ISLAND
SUBJECT TO CHANGE WITHOUT NOTICE
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS
ISD18/ISDH18/PYD18/PYDH18 “H” in part number indicates halogen lighting. These models not available
with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in
standard and custom sizes.
12”
12”
OPTIONAL
DUCT
COVER
HEIGHT
OPTIONAL
DUCT
COVER
12”
18”
3”
WID
TH
HEIGHT
12”
18”
4”
WID
TH
”
27
”
27
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
ISD18/ISDH18
PYD18/PYDH18
Connection Diagram (36" - 48" Widths)
Recommended
Mounting Height*
Centerline
Of Hood
Optional
Duct Cover
5" x 16"
Exhaust
Opening
Centerline
Of Hood
18”
7 ¾"
Electrical
8" Transition
Opening
8’ Ceiling
Vent Holes
550 CFM T200 Dual Blower
(Top View)
8" Round
30”
8" Round
36”
18"
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS
EPI18/EPIH18/SEPI18/SEPIH18 “H” in part number indicates halogen lighting. These models not
available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers
available in standard and custom sizes.
12”
12”
12”
OPTIONAL
DUCT
COVER
HEIGHT
OPTIONAL
DUCT
COVER
18”
4”
WID
TH
HEIGHT
12”
18”
3”
WID
TH
”
30
”
30
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
EPI18/EPIH18
SEPI18/SEPIH18
Connection Diagram (36" - 48" Widths)
Recommended
Mounting Height*
Centerline
Of Hood
Optional
Duct Cover
5" x 16"
Exhaust
Opening
Centerline
Of Hood
18”
7 ¾"
Electrical
8" Transition
Opening
8’ Ceiling
Vent Holes
550 CFM T200 Dual Blower
30”
(Top View)
8" Round
8" Round
36”
18"
9"
5"
*Exceeding recommended
mounting height may
compromise performance.
16"
VP565 Stadard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS
EPIT18/EPITH18/SEPIT18/SEPITH18 “H” in part number indicates halogen lighting. These models
not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers
available in standard and custom sizes.
15”
15”
OPTIONAL
DUCT
COVER
HEIGHT
OPTIONAL
DUCT
COVER
18”
4”
WID
TH
15”
HEIGHT
15”
18”
3”
WID
TH
”
30
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
EPIT18/EPITH18
”
30
SEPIT18/SEPITH18
Connection Diagram (48" - 66" Widths)
Recommended
Mounting Height*
Centerline
of Hood
Optional
Duct Cover
Electrical (2)
Vent Holes
7 ¾”
8” Blower
Outlets
Centerline
of Hood
12" Transition
Opening 2 ¼”
Above Top of
Hood
18”
8’ Ceiling
10 ½”
1100 CFM T400 Cluster Blower
30”
(Top View)
2 ¼”
12" Round
12" Round
36”
11 ¼"
8" Round
18”
8" Round
*Exceeding recommended
mounting height may
compromise performance.
8" Round
VP564 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T400 Island Cluster
Volts
Amps*
Hz
RPM
115
5.8
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
1100
1800
998
855
774
Minimum Round
Duct Size
12" (13 in.2)
Sones#
6.4
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two in front, two in back) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
CONTEMPORARY
ISLAND
SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND RANGE HOOD SPECIFICATIONS








CIEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional
duct cover(s) (sold separately). Optional duct covers available in standard and custom sizes.
OPTIONAL
DUCT
COVER
2 OPTIONAL
DUCT
COVERS


















CIEH9
(1100 CFM)










CIEH9
(550 CFM)
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
Recommended
Mounting Height*
Connection Diagram (36”- 54” Widths)
Centerline
of Hood
Centerline
of Hood
¾”
5” x 16”
Exhaust
Opening
2 �⁄�”
9"
8" Round
8" Round
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Vent Holes
9"
9"
5"
16"
550 CFM T200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View)
*Exceeding recommended
mounting height may
compromise performance.
Connection Diagram (60”- 66” Widths)
11”
11”
Centerline
of Hood
5” x 16”
Exhaust
Opening (2)
¾”
Electrical (2)
Vent Holes
9"
8" Round
8” Transition
Opening (2)
9” Above Top
of Hood
2 �⁄�”
8" Round
9"
9"
Centerline
of Hood
5"
16"
1100 CFM T2+200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(2 Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
CILH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional
duct cover (sold separately). Optional duct covers available in standard and custom sizes. Galley rail
included.
14
”
”
14
14
”
14
”
OPTIONAL
DUCT
COVER
2 OPTIONAL
DUCT
COVERS
4 ½”
4”
4 ½”
4 ½”
4 ½”
3”
4”
3”
5
¾”
”
20
”
0”
5¾
ths
2
id
”W
54
30
”
FM
0C
5¾
55
”
hs
&
8”,
4
2”,
-4
30
”
5¾
-6
idt
”W
66
”
1 ½”
�⁄��” Dia.
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
CILH9 (550 CFM)
FM
0C
0
11
0” &
CILH9 (1100 CFM)
Recommended
Mounting Height*
Optional
Duct Cover
Connection Diagram (42”- 54” Widths)
Centerline
of Hood
¾”
5” x 16”
Exhaust
Opening
2 �⁄�”
8" Round
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Vent Holes
9"
8" Round
8’ Ceiling
Centerline
of Hood
9”
9"
9"
5"
16"
550 CFM T200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View)
36”
*Exceeding recommended
mounting height may
compromise performance.
Connection Diagram (60”- 66” Widths)
11”
11”
Centerline
of Hood
5” x 16”
Exhaust
Opening (2)
¾”
Electrical (2)
Vent Holes
30”
8" Round
8” Transition
Opening (2)
9” Above Top
of Hood
2 �⁄�”
9"
8" Round
9"
9"
Centerline
of Hood
5"
16"
1100 CFM T2+200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(2 Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A
C
UL
R
US
ISLAND RANGE HOOD SPECIFICATIONS
IZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in
stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in
standard and custom sizes. Pot rail included.
OPTIONAL
DUCT
COVER
OPTIONAL
DUCT
COVER
”
15
18
”
OPTIONAL
DUCT
COVER
”
22
15
”
”
”
54
”
42
14”
30
”
22
15
”
”
66
14”
30
”
OPTIONAL
DUCT
COVER
”
OPTIONAL
DUCT
COVER
”
15
18
”
15
”
”
22
�⁄��” Dia.
1 ½”
IZDC Island Duct Cover
Mounting Holes
(Top View)
”
60
”
48
14”
30
14”
30
”
14”
30
”
Recommended
Mounting Height*
Connection Diagram (42" - 48" Widths)
7"
Centerline
of Hood
8" Round
8" Round
5” x 16”
Exhaust
Opening
Centerline
of Hood
Optional
Duct Cover
21"
9"
6 ¼”
Electrical
8” Transition
Opening 7”
Above Top
of Hood
Vent Holes
5"
14”
16"
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View)
8’ Ceiling
550 CFM T200 Dual Blower
Connection Diagram (54" - 66" Widths)
30”
Centerline
of Hood
10 ½”
9 ¼"
12" Round
12" Round
Vent Holes
8” Blower
Outlets
36”
Centerline
of Hood
23 ¼"
11 ¼"
Electrical
6 ¼”
12” Transition
Opening 9 ¼”
Above Top
of Hood
8" Round
8" Round
8" Round
1100 CFM T400 Cluster Blower
VP564 Transition
Transition Installed
(Top View)
(Included)
(Side View)
*Exceeding recommended
mounting height may
compromise performance.
NOTE: DUCT COVER EXTENDS 2”
INTO TOP OF HOOD.
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
T400 Island Cluster
Volts
Amps*
Hz
RPM
115
115
2.9
5.8
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
1100
1800
998
855
774
Minimum Round
Duct Size
8" (50 in.2)
12" (113 in.2)
Sones#
6.0
6.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808C
C
UL
R
US
WALL
MOUNT
LINER
SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT LINER INSERT SPECIFICATIONS
KHSLD LINER Halogen lights only. This model not available with heat lamps. This model only available
in Black, Biscuit, Gunsmoke Gray, Stainless Steel, or White.
The VP521 transition is available
for top vent applications
at an additional charge.
16 ½
”
AN
S TH IDTH
S
E
5” L TOM W
BOT
7”
2½
”
6”
28
18”
34
3⁄8”,
3⁄8”,
7 ½”
8”
0 3⁄
4
KHSLD
”
10”
3¼
Top Vent or Back Vent
3 ¼” x 10”
Connection Diagrams (28 3/8", 34 3/8", & 40 3/8" Widths)
Wall Cutout for Vertical Ducting
Viewed from Above
Recommended
Mounting Height*
Wall Cutout for Horizontal Ducting
Viewed from Front
Custom
Enclosure
7⁄8"
Top of Liner
2 5⁄8"
Back of
Liner
3 ½"
5"
5 1⁄8"
5 1⁄8"
5 1⁄8"
Electrical
7"
CL
6 ¼"
CL
8’ Ceiling
6”
21”-24”
36”
*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
K250 (Top Vent)
K250 (Back Vent)
Volts
Amps
Hz
RPM
115
115
3.2
3.2
60
60
1550
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
250
375
223
220
190
220
330
215
195
180
Minimum Round
Duct Size
7" (38 in.2)
7" (38 in.2)
Sones#
7.4
7.4
All K-Series hoods have two halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A
C
UL
R
US
WALL MOUNT LINER INSERT SPECIFICATIONS
BSLD/BHSLD LINER “H” in part number indicates halogen lighting. This model not available with heat
lamps.
12”
N
THA TH
ESS ID
6” L TOM W
T
BO
3”
12”
6
”, 4
19
28
¼”
3⁄8”,
34
3⁄8
40
3⁄8”,
3⁄8”
BSLD/BHSLD
Connection Diagram (28 3/8” - 40 3/8” Widths)
5 ¼”
Recommended
Mounting Height*
1 ¾”
1 3⁄8”
Wall Side
Custom
Enclosure
Vent
Hole
Electrical
6” Outlet
3 ¼”
Centerline
of Hood
12”
300 CFM B100 Single Blower
8’ Ceiling
(Top View)
Connection Diagram (28 3/8” - 46 3/8” Widths)
5 ½”
Wall Side
5 ¼”
Vent
Holes
1 ¾”
24”-27”
36”
8” Outlet
Electrical
Centerline
of Hood
600 CFM B200 Dual Blower
*Exceeding recommended
mounting height may
compromise performance.
(Top View)
Connection Diagram (46 3/8” Width)
7 5⁄16”
Wall Side
10” Round
7 5⁄16”
5 ½”
10” OR 12”
Round
10” Round
1 ¾”
1 7⁄8”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower) VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B100 Single
B200 Dual
B200 Dual & B100 Single
Volts
Amps*
Hz
RPM
115
115
115
1.5
2.9
4.4
60
60
60
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
300
450
273
245
225
6" (28 in.2)
600
900
531
480
430
8" (50 in.2)
900
1350
804
725
655
VP562: 10" (79 in.2)
Sones#
5.4
6.5
6.3
* Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0609A
C
UL
R
US
WALL MOUNT LINER INSERT SPECIFICATIONS
BPSLD/BHPSLD LINER “H” in part number indicates halogen lighting. This model not available with
heat lamps.
12”
N
THA TH
ESS ID
6” L TOM W
T
BO
3”
12”
22
�⁄�”,
40 ”,
�⁄�”, , 58 �⁄�
4
”
3
�⁄�”, 2 �⁄�
28 �⁄�”, 5 4 �⁄�”
6
46
½”
BPSLD/BHPSLD
Connection Diagram (28 3/8” - 52 3/8” Widths)
5 ½”
Wall Side
Recommended
Mounting Height*
5 ¼”
Vent
Holes
1 ¾”
Custom
Enclosure
8” Outlet
Electrical
Centerline
of Hood
12”
600 CFM B200 Dual Blower
8’ Ceiling
(Top View)
Connection Diagram (46 3/8” - 58 3/8” Widths)
7 �⁄��”
5 ½”
Wall Side
10” Round
7 �⁄��”
27”-30”
10” Round
1 ¾”
1 �⁄�”
Vent
Holes
17 ½”
36”
Electrical (2)
5 ¼”
Centerline
of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower) *Exceeding recommended
mounting height may
compromise performance.
10” OR 12”
Round
Connection Diagram (52 3/8” - 64 3/8” Widths)
11”
11”
5 ½”
12” Round
5 ½”
Wall Side
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
12” Round
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
VP562/VP563
transition
centers outlet
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
115
2.9
4.4
5.8
60
60
60
1550
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
600
900
531
480
430
8" (50 in.2)
6.5
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66").
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
WALL MOUNT LINER INSERT SPECIFICATIONS
BH340PSLB/B446PSLB/BH446PSLB LINER “H” in model number designates halogen lighting.
BH340PSLB is available with halogen lights only. This model not available with heat lamps.
12”
�⁄�”
40 �⁄�”
46
3”
12”
Recommended
Mounting Height*
22
Custom
Enclosure
½”
BH340PSLB/B446PSLB/BH446PSLB
12”
Connection Diagram (40-3/8" Width)
5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
8’ Ceiling
7 �⁄��”
1 ¾”
1 �⁄�”
Vent
Holes
17 ½”
Electrical (2)
5 ¼”
6” Outlet
Centerline
of Hood
8” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blowers
(Top View)
36”
VP562 Transition (Optional) For B300
(B200 Dual & B100 Single Blowers)
*Exceeding recommended
mounting height may
compromise performance.
Connection Diagram (46-3/8" Width)
11”
12” Round
11”
5 ½”
5 ½”
10” OR 12”
Round
12” Round
Wall Side
Vent
Holes
1 ¾”
16 ½”
8” Outlet
5 ¼”
8” Outlet
27”-30”
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Transition (Optional) For B400 Transition centers outlet
(Double B200 Dual Blowers)
over top of hood
Electrical/Mechanical Specifications For Blower Units
Model
B200 Dual & B100 Single
Two B200 Duals
Volts
Amps*
Hz
RPM
115
115
4.4
5.8
60
60
1550
1550
CFM
CFM
CFM
Minimum Round
• CFM
Sones#
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
Duct Size
900
1350
804
725
655
VP562: 10" (79 in.2)
6.3
1200
1800
1062
960
860
VP563: 12" (113 in.2)
6.6
* Add 0.5 amp for each halogen light. The B446PSLB is available with two fluorescent lights. Both models are available with three halogen lights.
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL
R
US
ISLAND
LINER
SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND LINER INSERT SPECIFICATIONS
TSLE/THSLE “H” in part number indicates halogen lighting. This model not available with heat
lamps.
15”
AN
TH DTH
S
S
LE WI
12” TOM
T
BO
3”
12”
”
48
2”,
”, 4
36
27”
TSLE/THSLE
Connection Diagram (36” - 48” Widths)
Recommended
Mounting Height*
Centerline
Of Hood
Centerline
Of Hood
2 �⁄�”
¾”
5” x 16”
Exhaust
Opening
Custom
Enclosure
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Vent Holes
12”
550 CFM T200 Dual Blower
8’ Ceiling
(Top View)
30”
9"
8" Round
8" Round
36”
9"
12"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended
mounting height may
compromise performance.
Electrical/Mechanical Specifications For Blower Units
Model
T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
550
900
507
471
431
Minimum Round
Duct Size
8" (50 in.2)
Sones#
6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US
ISLAND LINER INSERT SPECIFICATIONS
TPSLE/THPSLE “H” in part number indicates halogen lighting. This model not available with heat
lamps.
22”
AN
TH DTH
S
S
LE WI
16” TOM
T
BO
3”
12”
”
6
”, 6
,
48”
30”
, 60
54”
TPSLE/THPSLE
Connection Diagram (48” - 66” Widths)
Recommended
Mounting Height*
Centerline
of Hood
1 ¾"
Electrical (2)
Custom
Enclosure
Vent Holes
8” Blower
Outlets
Centerline
of Hood
5 ½"
12”
12" Transition
Opening 11 ¼"
Above Top
of Hood
8’ Ceiling
10 ½"
1100 CFM T400 Cluster Blower
(Top View)
12" Round
12" Round
30”
11 1/4"
36”
11 ¼"
12"
8" Round
8" Round
*Exceeding recommended
mounting height may
compromise performance.
8" Round
VP564 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units
Model
T400 Island Cluster
Volts
Amps*
Hz
RPM
115
5.8
60
1550
CFM
CFM
CFM
• CFM
[email protected]" Equivalent CFM [email protected]" [email protected]" [email protected]"
1100
1800
998
855
774
Minimum Round
Duct Size
12" (13 in.2)
Sones#
6.4
* Add 0.5 amp for each halogen bulb. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner).
• Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.
# Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL
R
US

Similar documents

BROCHURE Female RR_COR Ok:Layout 1

BROCHURE Female RR_COR Ok:Layout 1 COLL81 ABSOLUTE CAMELEON R E M OVA B L E FA C E S W I T H R E M OVA B L E L I P S

More information

Electrical and Ducting Specifications - Vent-A-Hood

Electrical and Ducting Specifications - Vent-A-Hood Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special duct requireme...

More information

SunMaster new catalogue 2014/2015

SunMaster new catalogue 2014/2015 Anti-days without sunshine Battery Battery Installation Battery life Wire 100%lighting throughout the year Human-friendly installation Overall performance

More information