Electrical and Ducting Specifications - Vent-A-Hood

Transcription

Electrical and Ducting Specifications - Vent-A-Hood
18420_Ventahood_Spec_Ctlg
9/11/08
5:47 PM
Page 1
Electrical and Ducting Specifications
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 2
Standard Blower Placements
SLH6-K Under-Cabinet Hood
Standard Blower Placements
Under Cabinet, Wall Mount, and Wall Mount Liner Inserts
Ceiling Cutout for Vertical Ducting
Viewed from Above
7⁄8"
Back of Cabinet
2 5⁄8"
5 ¼”
3 ½"
1 ¾”
1 3⁄8”
Wall Side
6" DIAMETER
Vent
Hole
5 1⁄8"
5 1⁄8"
6"
30"
Electrical
Electrical
6 ¼"
6” Outlet
3 ¼”
9"
12"
18"
Centerline
of Hood
CL
Top View- B100 Single Blower 300 CFM
Wall Cutout for Horizontal Ducting
Viewed from Front
7”
3⁄8"
7 ½”
Optional VP521 transition
is available for top-venting
applications
1 1⁄8"
Bottom of
Cabinet
3 ½"
”
3¼
5 ½”
Wall Side
5 ¼”
8" DIAMETER
Vent
Holes
1 ¾”
Electrical
10”
Side View- B100 Blower
30"
8” Outlet
Electrical
5 1⁄8"
8"
5 1⁄8"
9"
12"
18"
Centerline
of Hood
6 ¼"
Top View- B200 Dual Blower 600 CFM
CL
Side View- B200 Blower
For hoods wider than 66", consult the factory for blower outlet locations
KHSLD Liner Insert
8" DIAMETER
Ceiling
Cutoutfor
forVertical
VerticalDucting
Ducting
Wall Cutout
Viewed
Viewed from
from Above
Above
6" DIAMETER
Wall Side
7 5⁄16”
7 5⁄16”
5 ½”
1 7⁄8”
Vent
Holes
7⁄8"
17 ½”
5 ¼”
6” Outlet
Centerline
of Hood
8” Outlet
Back of
Liner
8” Round
5 1⁄8"
8” Round
6” Round
2”
VP562 Transition (Optional) for
B200 Dual & B100 Single Blower
Top View- B200 Dual Blower & B100 Single Blower 900 CFM
5 1⁄8"
10” Round
Electrical (2)
2 5⁄8"
3 ½"
10” Round
1 ¾”
Electrical
6 ¼"
CL
For hoods wider than 66", consult the factory for blower outlet locations
7”
Wall Cutout for Horizontal Ducting
Viewed from Front
7 ½”
Optional VP521 transition
is available for top-venting
applications
8" DIAMETER
11”
5 ½”
8" DIAMETER
11”
12” Round
5 ½”
Vent
Holes
16 ½”
1 ¾”
Top of Liner
5 ¼”
8” Outlet
5"
Electrical (2)
8” Outlet
Centerline
of Hood
Top View- Two B200 Dual Blowers 1200 CFM
10”
12” Round
Wall Side
”
3¼
5 1⁄8"
8” Round
8” Round
8” Round
3”
VP563 Transition (Optional) for
Two B200 Dual Blowers
7"
CL
2
For detailed individual specifications by model, visit our Web site at www.ventahood.com
3
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 4
Standard Blower Placements
Standard Blower Placements
Contemporary Wall Mount Hoods
Euro-Style Wall Mount Hoods
Ceiling Cutout for Vertical Ducting
Viewed from Above
GTH
Optional Duct Cover
1"
Optional Duct Cover
1 ¾”
1 7⁄8”
3 ¼" x 10"
Outlet
Wall Side
Blower
Exhaust
Outlet
Vent
Hole
6" Round
5"
4 ¼"
14"
6" DIAMETER
Electrical
5 ¼”
6" Outlet
Centerline
Of Hood
Outlet
Centerline
of Hood
Front View- B100 Single Blower
Electrical
6"
Top View- B100 Single Blower 300 CFM
Front View
K250 Ceiling Cutout For Vertical Ducting Viewed From Above
Wall Cutout For Horizontal
Ducting Viewed From Front
7”
Blower
Exhaust
Outlet
8" Round
5"
Optional Duct Cover
(Requires VP559 Back Vent Elbow, Sold Separately)
14"
5 ½”
Wall Side
5 ¼”
7 ½”
Vent
Holes
1 ¾”
8" DIAMETER
7⁄8”
3 ½”
8” Outlet
Electrical
Cutout
Area
10 ¼”
Front View- B200 Dual Blower
Blower
Exhaust
Outlet
10”
Centerline
of Hood
9"
”
3¼
18"
Optional VP521 transition
is available for top-venting
applications
Top View- B200 Dual Blower 600 CFM
Optional VP559 back vent elbow is
available for back vent applications
Wood
Mounting
Strip
8" Round
CL
Front View- B200 Dual Blower
ZTH
Optional Duct Cover
12 7⁄8”
9 1⁄8”
10"
Wall Side
Optional Duct Cover
1 ¾”
4 ½”
Wall Side
8 ½”
10" DIAMETER
5 ¼”
1 ¾”
Electrical (2)
Blower
Exhaust
Outlet
8” Round
Vent
Holes
5 ¼”
14 3⁄8”
9”
18"
10" Outlet
Centered On
Hood Top
Centerline
Of Hood
8” Outlet
Electrical
Top View- B200 Dual Blower & B100 Single Blower 900 CFM
Front View- B200 Dual Blower
Centerline
of Hood
Front View- VP562 Standard
Transition (Included)
Top View- B200 Dual Blower 600 CFM
Blower
Exhaust
Outlets
8” Round
6” Round
14 3⁄8”
9”
Front View- B200 Dual & Single Blower
Optional Duct Cover
Optional Duct Cover
1 ¾”
16 ½”
5 ½”
Wall Side
12"
12" DIAMETER
Wall Side
7 ½"
8 3⁄16"
1 7⁄8"
10” Round
Electrical (2)
10” Round
1 ¾"
Vent
Holes
7"
1 ¾”
6 7⁄16"
4 ½"
17 ½”
Electrical (2)
12" Outlet
Centered On
Top Of Hood
5 ¼"
18"
Centerline
Of Hood
8" Outlet
Centerline
Of Hood
6" Outlet
8” Round
8” Round
6” Round
2”
Top View- Two B200 Dual Blowers 1200 CFM
4
Front View- VP563 Standard
Transition (Included)
Top View- B200 Dual Blower & B100 Single Blower 900 CFM
VP562 Transition (Optional) for B200
Dual & B100 Single Blower
For detailed individual specifications by model, visit our Web site at www.ventahood.com
5
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 6
Standard Blower Placements
Standard Blower Placements
Contemporary Wall Mount Hoods
12" and 18" Island Hoods and Liner Inserts
1 ¾”
5 ¼”
½”
Wall Side
Centerline
of Hood
Vent
Hole
CWLH9
Optional Duct Cover
2 1⁄8”
Centerline
of Hood
1 ½”
6” Outlet
¾”
Centerline
of Hood
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Top View- B100 Single Blower 300 CFM
12"
Vent Holes
Side ViewTransition Installed
Top View- T200 Dual Blower 550 CFM
1 ¾”
4 ½”
Wall Side
5 ¼”
5 ¼”
9"
Vent Holes
8" Round
8" Round
8”
Outlet
Top View- B200 Dual Blower 600 CFM
7 1⁄16”
9"
18"
9"
Centerline
of Hood
Wall Side
9"
5” x 16”
Exhaust
Opening
Electrical
12"
5"
16"
Side ViewTransition Installed
VP565 Standard Transition (Included)
7 9⁄16”
10” Round
Side ViewTransition Installed
10” Round
1 ¾”
5 ½”
1 7⁄8”
Vent
Holes
Optional Duct Cover
17 ½”
Electrical (2)
11"
5 ¼”
8” Round
8” Round
6” Round
Top View- B200 Dual Blower & B100 Single Blower 900 CFM
VP562 Transition (Optional) for
B200 Dual & B100 Single Blower
12” Round
5 ½”
9"
18"
8" Round
12"
8" Round
8" Outlet
5 ¼”
Centerline
of Hood
Electrical (2)
8” Round
8” Round
8” Round
VP563 Transition (Optional) for
Two B200 Dual Blowers
Side ViewTransition Installed
9"
3”
Top View- Two B200 Dual Blowers 1200 CFM
On selected models, hoods wider than 66"
may be ordered with additional halogen
lighting between the blowers
5"
Side ViewTransition Installed
16"
Two VP565 Standard Transitions (Included)
Centerline
of Hood
1 ¾”
4 ½”
Wall Side
5 ¼”
Blower
Exhaust
Outlet
1 ¾"
8" Round
Electrical (2)
Vent Holes
5 ¼”
8” Outlet
Electrical
Wall Cutout For Horizontal
Ducting Viewed From Front
(Requires VP561 Back Vent Elbow, Sold Separately)
Cutout
Area
Centerline
of Hood
5 ½"
12"
Centerline
of Hood
Top View- B200 Dual Blower 600 CFM
Vent Holes
8” Blower
Outlets
3"
XLH12 with optional
10" x 10" duct cover
9"
Top View- Two T200 Dual Blowers 1100 CFM
12” Round
16 ½”
1 ¾”
XLH12 with optional round
duct collars and finished
round duct
8" Transition
Opening (2)
9" Above Top
Of Hood
Centerline
Of Hood
Vent Holes
Wall Side
Vent
Holes
8" Outlet
¾”
Electrical (2)
11”
5 ½”
5" x 16"
Exhaust
Opening (2)
2 1⁄8”
Centerline
Of Hood
2”
11”
11"
6" Outlet
Centerline
of Hood
8" Outlet
12" Transition
Opening 11 ¼"
Above Top
of Hood
Front View- B200 Dual Blower
11 1/4"
10 ½"
Top View- T400 Cluster Blower 1100 CFM
12" Tall Liner In
12"
12" Round
12" Round
Side ViewTransition Installed
9”
11 ¼"
XLH12 with optional square
duct collars and finished
round duct
6 ½”
3⁄8”
8" Round
8" Round
8" Round
VP564 Standard Transition (Included)
Wood
Mounting
Strip
6
CL
For detailed individual specifications by model, visit our Web site at www.ventahood.com
7
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 8
Standard Blower Placements
Standard Blower Placements
30" Tall Island Hoods
Euro-Style Island Hoods
Centerline
Of Hood
Centerline
Of Hood
3"
5" x 16"
Exhaust
Opening
Centerline
Of Hood
5" x 16"
Exhaust
Opening
Centerline
Of Hood
30"
Optional Duct Cover
30"
8" Transition
Opening
Vent Holes
Vent Holes
7 ¾"
Electrical
7 ¾"
Electrical
8" Transition
Opening 3”
Below Top
of Hood
18"
Side ViewTransition Installed
Top View- T200 Dual Blower 550 CFM
Top View- T200 Dual Blower 550 CFM
Side ViewTransition Installed
8" Round
8" Round
8" Round
8" Round
9"
9"
11”
11”
5” x 16”
Exhaust
Opening (s)
Centerline
of Hood
30"
7 ¼”
Vent Holes
Electrical (2)
Centerline
of Hood
8” Transition
Opening (2)
3” Below Top
of Hood
5"
16"
16"
VP565 Standard Transition (Included)
T200 Dual Blower Includes One
VP565 Standard Transition.
Two T200 Dual Blowers Includes
Two VP565 Standard Transitions
Top View- Two T200 Dual Blowers 1100 CFM
®
5"
®
Centerline
of Hood
What makes a Vent-A-Hood a Vent-A-Hood ?
Electrical (2)
Quiet.
Turn on a Vent-A-Hood® range hood, and you’ll hear only a whisper of air movement, because the Magic Lung® blower system provides the quietest
ventilation available. Unbiased tests show that the Magic Lung® blower has one of the lowest sound ratings in the industry – especially at high speed –
where it counts.
Efficient.
The powerful Magic Lung® blower traps cooking contaminants, liquifies grease vapor and removes heat polluted air. It combines sufficient air pressure
and constant speed centrifugal filtration – and because it doesn’t pull air through a filter – it provides the most efficient kitchen ventilation available
today. This filtration system, along with the open canopy design of a Vent-A-Hood®, delivers performance far
more efficiently than other filtration systems.
Optional Duct Cover
8” Blower
Outlets
7 ¾”
Vent Holes
Centerline
of Hood
12" Transition
Opening 2 ¼”
Above Top of
Hood
2 ¼”
10 ½”
18”
Top View- T400 Cluster Blower 1100 CFM
Easy-cleaning.
The Magic Lung® blower housing snaps apart for easy cleaning in the dishwasher or with warm soapy water. The
Magic Lung® motor is also enclosed in a specially designed housing to keep it out of the grease flow, thereby
maximizing its operational performance. Easy to snap-apart housings and fully enclosed motors mean no hidden
grease in hard to reach areas behind a mesh or baffle filter as with other brands in the marketplace.
Side ViewTransition Installed
12" Round
12" Round
Fire-safety.
The Magic Lung® constant speed centrifugal blower is designed to liquefy grease in the sealed blower housing
and to create a pressure barrier, lowering the risk of an attic or wall fire. In 70+ years of manufacturing this
system, Vent-A-Hood® has never received a report of an attic or wall fire when the Magic Lung® has been in use.
Powerful.
Magic Lung® blowers can be configured to provide the power you need for even the most demanding cooking surface.
Each highly efficient Magic Lung® blower supplies 300 CFM of air movement; you can combine multiple blowers in a single Vent-A-Hood® range hood to
create the perfect ventilation for your cooking surface.
8
11 ¼"
8" Round
8" Round
8" Round
VP564 Standard Transition (Included)
For detailed individual specifications by model, visit our Web site at www.ventahood.com
9
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 10
Standard Blower Placements
Electrical and Ducting Specifications
Contemporary Island Hoods
CILH9
Model
Volts
Amps*
RPM
CFM
[email protected]"†
Equivalent
CFM‡
CFM
[email protected]"
CFM
[email protected]"
CFM
[email protected]"
Minimum Round
Duct Size
B100
115
1.5
1550
300
450
273
245
225
6"( 28 in )
B200
115
2.9
1550
600
900
531
480
430
8"( 50 in )
B200 Dual & B100 Single
115
4.4
1550
900
1350
804
725
655
10"( 79 in )
Two B200 Duals
115
5.8
1550
1200
1800
1062
960
860
12"( 113 in )
K250 (Top Vent)
115
2.2
1550
250
375
223
220
190
7"( 38 in )
K250 (Back Vent)
115
2.2
1550
220
330
215
195
180
7"( 38 in )
T200 Dual
115
2.9
1550
550
900
507
471
431
8"( 50 in )
T400 Cluster
115
5.8
1550
1100
1800
998
855
774
12"( 113 in )
RM1000 Remote
115
3.2
1100
945
N/A
922
884
852
10"( 79 in )
RM1500 Remote
115
5.0
1130
1500
N/A
1455
1410
1375
10"( 79 in )
9"
Centerline
of Hood
Optional Duct Cover
2
Sones§
5.4
9"
5” x 16”
Exhaust
Opening
2 1⁄8”
Centerline
of Hood
Side ViewTransition Installed
¾”
8” Transition
Opening 9”
Above Top
of Hood
Electrical
Vent Holes
8" Round
2
2
2
6.5
6.3
6.6
8" Round
2
7.4
2
7.4
9"
Top View- T200 Dual Blower 550 CFM
5"
16"
VP565 Standard Transition (Included)
2
2
6.0
6.4
2
N/A
2
N/A
9"
* Add 2.5 amps for each warming lamp and 0.5 additional amp for each halogen light bulb. In general, there will be one halogen light for every 14"
of hood width, evenly spaced along the light box. Island hoods will have four halogen lights, one in each corner. Model GTH has two halogen lights,
one on each side. Model ZTH has four halogen lights, two on each side. Hoods equipped with fluorescent lighting will have one light fixture
per blower unit except for island hoods, which have two (on the front and back of the hood).
† CFM rating is based on 0.0 inches static pressure (resistance in the ducting, turns, roof caps, etc.) CFM rating will change as static pressure is
increased. Static pressure increases because of ducting and length of duct run.
‡ Equivalent CFM refers to the fact that the Magic Lung® uses centrifugal filtration units, whereas others use conventional filters. Apply this
guideline when comparing blower units made by other manufacturers.
§ Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. All tests were
measured at full speed to demonstrate the most accurate sound rating (other manufacturers may use lower speeds for testing which don't reflect
accurate operating sound levels).
CILH9
Optional Duct Covers
9"
11”
11”
Side ViewTransition Installed
5” x 16”
Exhaust
Opening (2)
Centerline
of Hood
¾”
Electrical (2)
8” Transition
Opening (2)
9” Above Top
of Hood
2 1⁄8”
Vent Holes
8" Round
8" Round
Centerline
of Hood
9"
Top View- Two T200 Dual Blowers 1100 CFM
5"
16"
Two VP565 Standard Transitions (Included)
7"
YES
IZTH
Optional Duct Cover
NEVER restrict the duct size. When combining ducts together, the square inch area must reflect the total
square inch area of the ducts being combined. Using Vent-A-Hood transitions (where applicable) will ensure
proper efficiency.
21"
Centerline
of Hood
5” x 16”
Exhaust
Opening
Centerline
of Hood
6 ¼”
Electrical
8” Transition
Opening 7”
Above Top
of Hood
Vent Holes
Side ViewTransition Installed
8" Round
8" Round
Top View- T200 Dual Blower 550 CFM
9"
5"
16"
VP565 Standard Transition (Included)
9 ¼"
IZTH
Centerline
of Hood
Optional Duct Cover
Ducting Do’s and Don’ts
NO
23 ¼"
10 ½”
Blower
Duct Size
K250
Single (B100)
Dual (B200)
Dual (T200)
Dual and Single (B200 & B100)
Two Dual (Two B200s)
Cluster (T400)
3 1/4" x 10" or equivalent
6" round or equivalent
8" round or equivalent
8" round or equivalent
10" round or equivalent
12" round or equivalent
12" round or equivalent
Sq. Inch Area
32.5"
28"
50"
50"
79"
113"
113"
Vent-A-Hood Transition
N/A
N/A
N/A
VP565 (Included)
VP562 (Optional)
VP563 (Optional)
VP564 (Included)
Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only
use smooth, galvanized, metal duct. Observe local codes regarding special duct requirements and placement
of duct against combustibles. Make the duct run as short and as straight as possible with as few turns as
possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree
angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90
degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers will ensure proper
efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded
doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. Where possible, seal
joints with duct tape. The hood must be ducted to the outdoors without restrictions.
Vent Holes
8” Blower
Outlets
Centerline
of Hood
Electrical
6 ¼”
12” Transition
Opening 9 ¼”
Above Top
of Hood
Side ViewTransition Installed
12" Round
12" Round
11 ¼"
Top View- T400 Cluster Blower 1100 CFM
8" Round
10
8" Round
8" Round
VP564 Standard Transition (Included)
For detailed individual specifications by model, visit our Web site at www.ventahood.com
11
18420_Ventahood_Spec_Ctlg
9/11/08
5:48 PM
Page 12
P.O. Box 830426
1000 N. Greenville Ave.
Richardson, TX 75083-0426
800-331-2492
www.ventahood.com