Electrical and Ducting Specifications - Vent-A-Hood
Transcription
Electrical and Ducting Specifications - Vent-A-Hood
18420_Ventahood_Spec_Ctlg 9/11/08 5:47 PM Page 1 Electrical and Ducting Specifications 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 2 Standard Blower Placements SLH6-K Under-Cabinet Hood Standard Blower Placements Under Cabinet, Wall Mount, and Wall Mount Liner Inserts Ceiling Cutout for Vertical Ducting Viewed from Above 7⁄8" Back of Cabinet 2 5⁄8" 5 ¼” 3 ½" 1 ¾” 1 3⁄8” Wall Side 6" DIAMETER Vent Hole 5 1⁄8" 5 1⁄8" 6" 30" Electrical Electrical 6 ¼" 6” Outlet 3 ¼” 9" 12" 18" Centerline of Hood CL Top View- B100 Single Blower 300 CFM Wall Cutout for Horizontal Ducting Viewed from Front 7” 3⁄8" 7 ½” Optional VP521 transition is available for top-venting applications 1 1⁄8" Bottom of Cabinet 3 ½" ” 3¼ 5 ½” Wall Side 5 ¼” 8" DIAMETER Vent Holes 1 ¾” Electrical 10” Side View- B100 Blower 30" 8” Outlet Electrical 5 1⁄8" 8" 5 1⁄8" 9" 12" 18" Centerline of Hood 6 ¼" Top View- B200 Dual Blower 600 CFM CL Side View- B200 Blower For hoods wider than 66", consult the factory for blower outlet locations KHSLD Liner Insert 8" DIAMETER Ceiling Cutoutfor forVertical VerticalDucting Ducting Wall Cutout Viewed Viewed from from Above Above 6" DIAMETER Wall Side 7 5⁄16” 7 5⁄16” 5 ½” 1 7⁄8” Vent Holes 7⁄8" 17 ½” 5 ¼” 6” Outlet Centerline of Hood 8” Outlet Back of Liner 8” Round 5 1⁄8" 8” Round 6” Round 2” VP562 Transition (Optional) for B200 Dual & B100 Single Blower Top View- B200 Dual Blower & B100 Single Blower 900 CFM 5 1⁄8" 10” Round Electrical (2) 2 5⁄8" 3 ½" 10” Round 1 ¾” Electrical 6 ¼" CL For hoods wider than 66", consult the factory for blower outlet locations 7” Wall Cutout for Horizontal Ducting Viewed from Front 7 ½” Optional VP521 transition is available for top-venting applications 8" DIAMETER 11” 5 ½” 8" DIAMETER 11” 12” Round 5 ½” Vent Holes 16 ½” 1 ¾” Top of Liner 5 ¼” 8” Outlet 5" Electrical (2) 8” Outlet Centerline of Hood Top View- Two B200 Dual Blowers 1200 CFM 10” 12” Round Wall Side ” 3¼ 5 1⁄8" 8” Round 8” Round 8” Round 3” VP563 Transition (Optional) for Two B200 Dual Blowers 7" CL 2 For detailed individual specifications by model, visit our Web site at www.ventahood.com 3 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 4 Standard Blower Placements Standard Blower Placements Contemporary Wall Mount Hoods Euro-Style Wall Mount Hoods Ceiling Cutout for Vertical Ducting Viewed from Above GTH Optional Duct Cover 1" Optional Duct Cover 1 ¾” 1 7⁄8” 3 ¼" x 10" Outlet Wall Side Blower Exhaust Outlet Vent Hole 6" Round 5" 4 ¼" 14" 6" DIAMETER Electrical 5 ¼” 6" Outlet Centerline Of Hood Outlet Centerline of Hood Front View- B100 Single Blower Electrical 6" Top View- B100 Single Blower 300 CFM Front View K250 Ceiling Cutout For Vertical Ducting Viewed From Above Wall Cutout For Horizontal Ducting Viewed From Front 7” Blower Exhaust Outlet 8" Round 5" Optional Duct Cover (Requires VP559 Back Vent Elbow, Sold Separately) 14" 5 ½” Wall Side 5 ¼” 7 ½” Vent Holes 1 ¾” 8" DIAMETER 7⁄8” 3 ½” 8” Outlet Electrical Cutout Area 10 ¼” Front View- B200 Dual Blower Blower Exhaust Outlet 10” Centerline of Hood 9" ” 3¼ 18" Optional VP521 transition is available for top-venting applications Top View- B200 Dual Blower 600 CFM Optional VP559 back vent elbow is available for back vent applications Wood Mounting Strip 8" Round CL Front View- B200 Dual Blower ZTH Optional Duct Cover 12 7⁄8” 9 1⁄8” 10" Wall Side Optional Duct Cover 1 ¾” 4 ½” Wall Side 8 ½” 10" DIAMETER 5 ¼” 1 ¾” Electrical (2) Blower Exhaust Outlet 8” Round Vent Holes 5 ¼” 14 3⁄8” 9” 18" 10" Outlet Centered On Hood Top Centerline Of Hood 8” Outlet Electrical Top View- B200 Dual Blower & B100 Single Blower 900 CFM Front View- B200 Dual Blower Centerline of Hood Front View- VP562 Standard Transition (Included) Top View- B200 Dual Blower 600 CFM Blower Exhaust Outlets 8” Round 6” Round 14 3⁄8” 9” Front View- B200 Dual & Single Blower Optional Duct Cover Optional Duct Cover 1 ¾” 16 ½” 5 ½” Wall Side 12" 12" DIAMETER Wall Side 7 ½" 8 3⁄16" 1 7⁄8" 10” Round Electrical (2) 10” Round 1 ¾" Vent Holes 7" 1 ¾” 6 7⁄16" 4 ½" 17 ½” Electrical (2) 12" Outlet Centered On Top Of Hood 5 ¼" 18" Centerline Of Hood 8" Outlet Centerline Of Hood 6" Outlet 8” Round 8” Round 6” Round 2” Top View- Two B200 Dual Blowers 1200 CFM 4 Front View- VP563 Standard Transition (Included) Top View- B200 Dual Blower & B100 Single Blower 900 CFM VP562 Transition (Optional) for B200 Dual & B100 Single Blower For detailed individual specifications by model, visit our Web site at www.ventahood.com 5 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 6 Standard Blower Placements Standard Blower Placements Contemporary Wall Mount Hoods 12" and 18" Island Hoods and Liner Inserts 1 ¾” 5 ¼” ½” Wall Side Centerline of Hood Vent Hole CWLH9 Optional Duct Cover 2 1⁄8” Centerline of Hood 1 ½” 6” Outlet ¾” Centerline of Hood 8” Transition Opening 9” Above Top of Hood Electrical Top View- B100 Single Blower 300 CFM 12" Vent Holes Side ViewTransition Installed Top View- T200 Dual Blower 550 CFM 1 ¾” 4 ½” Wall Side 5 ¼” 5 ¼” 9" Vent Holes 8" Round 8" Round 8” Outlet Top View- B200 Dual Blower 600 CFM 7 1⁄16” 9" 18" 9" Centerline of Hood Wall Side 9" 5” x 16” Exhaust Opening Electrical 12" 5" 16" Side ViewTransition Installed VP565 Standard Transition (Included) 7 9⁄16” 10” Round Side ViewTransition Installed 10” Round 1 ¾” 5 ½” 1 7⁄8” Vent Holes Optional Duct Cover 17 ½” Electrical (2) 11" 5 ¼” 8” Round 8” Round 6” Round Top View- B200 Dual Blower & B100 Single Blower 900 CFM VP562 Transition (Optional) for B200 Dual & B100 Single Blower 12” Round 5 ½” 9" 18" 8" Round 12" 8" Round 8" Outlet 5 ¼” Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round VP563 Transition (Optional) for Two B200 Dual Blowers Side ViewTransition Installed 9" 3” Top View- Two B200 Dual Blowers 1200 CFM On selected models, hoods wider than 66" may be ordered with additional halogen lighting between the blowers 5" Side ViewTransition Installed 16" Two VP565 Standard Transitions (Included) Centerline of Hood 1 ¾” 4 ½” Wall Side 5 ¼” Blower Exhaust Outlet 1 ¾" 8" Round Electrical (2) Vent Holes 5 ¼” 8” Outlet Electrical Wall Cutout For Horizontal Ducting Viewed From Front (Requires VP561 Back Vent Elbow, Sold Separately) Cutout Area Centerline of Hood 5 ½" 12" Centerline of Hood Top View- B200 Dual Blower 600 CFM Vent Holes 8” Blower Outlets 3" XLH12 with optional 10" x 10" duct cover 9" Top View- Two T200 Dual Blowers 1100 CFM 12” Round 16 ½” 1 ¾” XLH12 with optional round duct collars and finished round duct 8" Transition Opening (2) 9" Above Top Of Hood Centerline Of Hood Vent Holes Wall Side Vent Holes 8" Outlet ¾” Electrical (2) 11” 5 ½” 5" x 16" Exhaust Opening (2) 2 1⁄8” Centerline Of Hood 2” 11” 11" 6" Outlet Centerline of Hood 8" Outlet 12" Transition Opening 11 ¼" Above Top of Hood Front View- B200 Dual Blower 11 1/4" 10 ½" Top View- T400 Cluster Blower 1100 CFM 12" Tall Liner In 12" 12" Round 12" Round Side ViewTransition Installed 9” 11 ¼" XLH12 with optional square duct collars and finished round duct 6 ½” 3⁄8” 8" Round 8" Round 8" Round VP564 Standard Transition (Included) Wood Mounting Strip 6 CL For detailed individual specifications by model, visit our Web site at www.ventahood.com 7 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 8 Standard Blower Placements Standard Blower Placements 30" Tall Island Hoods Euro-Style Island Hoods Centerline Of Hood Centerline Of Hood 3" 5" x 16" Exhaust Opening Centerline Of Hood 5" x 16" Exhaust Opening Centerline Of Hood 30" Optional Duct Cover 30" 8" Transition Opening Vent Holes Vent Holes 7 ¾" Electrical 7 ¾" Electrical 8" Transition Opening 3” Below Top of Hood 18" Side ViewTransition Installed Top View- T200 Dual Blower 550 CFM Top View- T200 Dual Blower 550 CFM Side ViewTransition Installed 8" Round 8" Round 8" Round 8" Round 9" 9" 11” 11” 5” x 16” Exhaust Opening (s) Centerline of Hood 30" 7 ¼” Vent Holes Electrical (2) Centerline of Hood 8” Transition Opening (2) 3” Below Top of Hood 5" 16" 16" VP565 Standard Transition (Included) T200 Dual Blower Includes One VP565 Standard Transition. Two T200 Dual Blowers Includes Two VP565 Standard Transitions Top View- Two T200 Dual Blowers 1100 CFM ® 5" ® Centerline of Hood What makes a Vent-A-Hood a Vent-A-Hood ? Electrical (2) Quiet. Turn on a Vent-A-Hood® range hood, and you’ll hear only a whisper of air movement, because the Magic Lung® blower system provides the quietest ventilation available. Unbiased tests show that the Magic Lung® blower has one of the lowest sound ratings in the industry – especially at high speed – where it counts. Efficient. The powerful Magic Lung® blower traps cooking contaminants, liquifies grease vapor and removes heat polluted air. It combines sufficient air pressure and constant speed centrifugal filtration – and because it doesn’t pull air through a filter – it provides the most efficient kitchen ventilation available today. This filtration system, along with the open canopy design of a Vent-A-Hood®, delivers performance far more efficiently than other filtration systems. Optional Duct Cover 8” Blower Outlets 7 ¾” Vent Holes Centerline of Hood 12" Transition Opening 2 ¼” Above Top of Hood 2 ¼” 10 ½” 18” Top View- T400 Cluster Blower 1100 CFM Easy-cleaning. The Magic Lung® blower housing snaps apart for easy cleaning in the dishwasher or with warm soapy water. The Magic Lung® motor is also enclosed in a specially designed housing to keep it out of the grease flow, thereby maximizing its operational performance. Easy to snap-apart housings and fully enclosed motors mean no hidden grease in hard to reach areas behind a mesh or baffle filter as with other brands in the marketplace. Side ViewTransition Installed 12" Round 12" Round Fire-safety. The Magic Lung® constant speed centrifugal blower is designed to liquefy grease in the sealed blower housing and to create a pressure barrier, lowering the risk of an attic or wall fire. In 70+ years of manufacturing this system, Vent-A-Hood® has never received a report of an attic or wall fire when the Magic Lung® has been in use. Powerful. Magic Lung® blowers can be configured to provide the power you need for even the most demanding cooking surface. Each highly efficient Magic Lung® blower supplies 300 CFM of air movement; you can combine multiple blowers in a single Vent-A-Hood® range hood to create the perfect ventilation for your cooking surface. 8 11 ¼" 8" Round 8" Round 8" Round VP564 Standard Transition (Included) For detailed individual specifications by model, visit our Web site at www.ventahood.com 9 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 10 Standard Blower Placements Electrical and Ducting Specifications Contemporary Island Hoods CILH9 Model Volts Amps* RPM CFM [email protected]"† Equivalent CFM‡ CFM [email protected]" CFM [email protected]" CFM [email protected]" Minimum Round Duct Size B100 115 1.5 1550 300 450 273 245 225 6"( 28 in ) B200 115 2.9 1550 600 900 531 480 430 8"( 50 in ) B200 Dual & B100 Single 115 4.4 1550 900 1350 804 725 655 10"( 79 in ) Two B200 Duals 115 5.8 1550 1200 1800 1062 960 860 12"( 113 in ) K250 (Top Vent) 115 2.2 1550 250 375 223 220 190 7"( 38 in ) K250 (Back Vent) 115 2.2 1550 220 330 215 195 180 7"( 38 in ) T200 Dual 115 2.9 1550 550 900 507 471 431 8"( 50 in ) T400 Cluster 115 5.8 1550 1100 1800 998 855 774 12"( 113 in ) RM1000 Remote 115 3.2 1100 945 N/A 922 884 852 10"( 79 in ) RM1500 Remote 115 5.0 1130 1500 N/A 1455 1410 1375 10"( 79 in ) 9" Centerline of Hood Optional Duct Cover 2 Sones§ 5.4 9" 5” x 16” Exhaust Opening 2 1⁄8” Centerline of Hood Side ViewTransition Installed ¾” 8” Transition Opening 9” Above Top of Hood Electrical Vent Holes 8" Round 2 2 2 6.5 6.3 6.6 8" Round 2 7.4 2 7.4 9" Top View- T200 Dual Blower 550 CFM 5" 16" VP565 Standard Transition (Included) 2 2 6.0 6.4 2 N/A 2 N/A 9" * Add 2.5 amps for each warming lamp and 0.5 additional amp for each halogen light bulb. In general, there will be one halogen light for every 14" of hood width, evenly spaced along the light box. Island hoods will have four halogen lights, one in each corner. Model GTH has two halogen lights, one on each side. Model ZTH has four halogen lights, two on each side. Hoods equipped with fluorescent lighting will have one light fixture per blower unit except for island hoods, which have two (on the front and back of the hood). † CFM rating is based on 0.0 inches static pressure (resistance in the ducting, turns, roof caps, etc.) CFM rating will change as static pressure is increased. Static pressure increases because of ducting and length of duct run. ‡ Equivalent CFM refers to the fact that the Magic Lung® uses centrifugal filtration units, whereas others use conventional filters. Apply this guideline when comparing blower units made by other manufacturers. § Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. All tests were measured at full speed to demonstrate the most accurate sound rating (other manufacturers may use lower speeds for testing which don't reflect accurate operating sound levels). CILH9 Optional Duct Covers 9" 11” 11” Side ViewTransition Installed 5” x 16” Exhaust Opening (2) Centerline of Hood ¾” Electrical (2) 8” Transition Opening (2) 9” Above Top of Hood 2 1⁄8” Vent Holes 8" Round 8" Round Centerline of Hood 9" Top View- Two T200 Dual Blowers 1100 CFM 5" 16" Two VP565 Standard Transitions (Included) 7" YES IZTH Optional Duct Cover NEVER restrict the duct size. When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined. Using Vent-A-Hood transitions (where applicable) will ensure proper efficiency. 21" Centerline of Hood 5” x 16” Exhaust Opening Centerline of Hood 6 ¼” Electrical 8” Transition Opening 7” Above Top of Hood Vent Holes Side ViewTransition Installed 8" Round 8" Round Top View- T200 Dual Blower 550 CFM 9" 5" 16" VP565 Standard Transition (Included) 9 ¼" IZTH Centerline of Hood Optional Duct Cover Ducting Do’s and Don’ts NO 23 ¼" 10 ½” Blower Duct Size K250 Single (B100) Dual (B200) Dual (T200) Dual and Single (B200 & B100) Two Dual (Two B200s) Cluster (T400) 3 1/4" x 10" or equivalent 6" round or equivalent 8" round or equivalent 8" round or equivalent 10" round or equivalent 12" round or equivalent 12" round or equivalent Sq. Inch Area 32.5" 28" 50" 50" 79" 113" 113" Vent-A-Hood Transition N/A N/A N/A VP565 (Included) VP562 (Optional) VP563 (Optional) VP564 (Included) Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special duct requirements and placement of duct against combustibles. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers will ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. Vent Holes 8” Blower Outlets Centerline of Hood Electrical 6 ¼” 12” Transition Opening 9 ¼” Above Top of Hood Side ViewTransition Installed 12" Round 12" Round 11 ¼" Top View- T400 Cluster Blower 1100 CFM 8" Round 10 8" Round 8" Round VP564 Standard Transition (Included) For detailed individual specifications by model, visit our Web site at www.ventahood.com 11 18420_Ventahood_Spec_Ctlg 9/11/08 5:48 PM Page 12 P.O. Box 830426 1000 N. Greenville Ave. Richardson, TX 75083-0426 800-331-2492 www.ventahood.com