PRECAST - Bison Manufacturing Limited

Transcription

PRECAST - Bison Manufacturing Limited
Uniclass
L4322:P22
EPIC
D34:X22
CI/SfB
(24)
Ef2
September 2008
LEADING THE PRECAST INDUSTRY SINCE 1919
PRECAST
STAIRS AND LANDINGS
CONTENTS
This Bison precast concrete stairs and landings document is a comprehensive
product and technical guide designed for Structural Engineers, Civil Engineers,
Specifiers and Contractors.
INTRODUCTION
PAGES 1 - 5
It provides a range of products and solutions to choose from and is supported by
technical details, specifications and design guidelines/considerations.
PRECAST STAIRS AND LANDINGS
01
PRECAST STAIRS AND LANDINGS DETAILS
02
BUILDING REGULATIONS
03
SPECIFICATION DETAILS
04
HEALTH AND SAFETY
05
DESIGN SOLUTIONS
06
SERVICE AND DELIVERY
07
SUSTAINABILITY
08
BISON ONLINE
08
PAGES 6 - 7
PAGES 8 - 17
PAGES 18 - 19
PAGES 20 - 21
PAGES 22 - 23
PAGES 24 - 25
PAGES 26 - 27
PAGE 28
PAGE 29
2
3
3
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
BISON
BISON
UNRIVALLED CONSISTENT QUALITY
QUALITY of Product FINISH
Bison has led the precast concrete industry since 1919. Our investment in technology,
Our investment is focused on meeting and exceeding customer expectations.
innovation and our people has ensured we have remained at the forefront of
Our modern and innovative manufacturing techniques alongside state of the art production
developments in design, technical expertise and customer service.
processes, ensure the quality of our products is second to none and we take pride in
producing both functional and architectural products to provide the very best finish.
THE MOST ADVANCED
MANUFACTURING FACILITY
Bison is fully committed to the UK manufacturing industry and we take great
pride in our state of the art, flagship manufacturing facility in Swadlincote.
As the most advanced and sustainable precast concrete plant in the world,
Bison can guarantee exceptional service and product quality across a wide
range of market sectors and projects throughout the UK.
4
5
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
BISON
BISON
THE BENEFITS
PROVEN TRACK RECORD
RAPID CONSTRUCTION
CUSTOMER SATISFACTION
Bison precast staircases are delivered to site ready for
Each of Bison’s manufacturing facilities are members
ARORA INTERNATIONAL,
HEATHROW T5
installation and can speed up construction schedules to
of the B.S.I Registered Firms Scheme for Quality
Bison designed, manufactured, delivered and erected
provide safe and immediate routes between floors under
Assurance to BS EN ISO 9001:2000 for the design and
30,000m2 of bespoke precast concrete products for the
construction. Once hoisted into place, the precast stair
manufacture of precast concrete products.
610 bedroom, 6 hotel development, the largest luxury
flight is suitably protected and ready for use.
01
airport hotel in Europe. Tight time scales meant that the
Bison team were frequently on site 24 hours a day, seven
days a week working on the project, which included
PROVEN QUALITY AT
ECONOMIC COST
Registration No. FM 11
Exceptional quality is built into each precast stair structure
In accordance with the requirements of the scheme,
to ensure the most appropriate, efficient and cost-effective
all procedures and disciplines undertaken by Bison
WEMBLEY STADIUM
product solution. Precast stairs reduce the requirement for
are subject to independent approval and periodic
The Bison team effectively designed, manufactured and
complex on-site shuttering and minimise the risk of delays
review by the British Standards Institution.
delivered the major precast elements of the stadium on
REGISRATION No. FM 11
features such as full height interlinking glass atriums.
time and to budget.
that can occur with site-poured concrete.
All aspects of Bison’s design, production, detailing
STANDARD MOULDS WITH
VERSATILE DESIGN
Manufactured in precision steel, the precast stair moulds
offer any riser height, combined with a range of tread
dimensions to provide a customised stair design from
standard moulds.
and quality control methods are independently
inspected, achieving a high level of capability
and quality. Customers can have confidence in
the performance and quality standards of Bison’s
products to ensure a competent precast concrete
solution is specified and installed regardless of project
complexity or requirement.
IKEA WAREHOUSE, COVENTRY
Design, manufacture, deliver and erect the precast
EASE OF INSTALLATION
Bison’s lifting pins are cast into the precast concrete during
manufacture in the factory, making on-site installation safer,
easier and quicker.
CONTINUOUS PRODUCT
DEVELOPMENT POLICY
concrete products for the 480,000 square foot structure.
Bison operates a policy of continuous product
development and improvement, supported by the very
latest research and development and state of the art
manufacturing facilities. Our approach is geared to
offer customers market leading, cost-effective, precast
concrete solutions with the highest standards of
quality and performance.
SPORTCITY, MANCHESTER
Complex space planning challenge for multi-storey
residential property where an innovative and iconic
building was required. Proposed circular design for
attractive, usable apartments was made workable
by Bison, offering the client practical solutions to the
challenges presented.
6
7
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
02
250 min
dimension
REINFORCED CONCRETE
STAIR FLIGHT
UNIT PROFILE
STAIRCASE
LANDING DETAILS
Cast in loadbearing angle
40mm to U/S angle
Tread
250mm
TYPICAL ATTACHED LOWER LANDING
200mm
275mm
Riser height as required
305mm
Available range
Riser height as required
Available range
150 - 210mm
Going
150 - 210mm
Attached landing
Variable range of sizes
to specification
Riser
Waist
150mm ...
Nominal
25mm
In 25mm increments
TYPICAL ATTACHED UPPER LANDING
200mm
25mm
Riser height as required
O/A Length
Available range
150 - 210mm
Effective span
Attached landing
Note:
Variable range of sizes
Weight limit on stair is 10t. Contact Bison for further information
to specification
REINFORCED CONCRETE STAIR FLIGHT
DIMENSIONS
152
156
160
164
168
172
176
180
184
188
192
196
200
204
208
RECEDE
21.5
22.0
22.5
23.0
23.5
24.0
24.5
25.0
25.5
26.0
26.5
27.0
27.5
28.5
29.0
250
228.5
228.0
227.5
226.5
226.0
225.5
225.0
224.5
224.0
223.5
223.0
222.5
253.5
253.0
252.5
252.0
252.5
251.0
250.5
250.0
283.5
283.0
282.5
282.0
281.5
281.0
280.5
280.0
TREAD
RISER
275
305
GOING
TYPICAL ATTACHED LANDINGS
Riser height as required
Available range
150 - 210mm
279.5
279.0
278.5
278.0
277.5
277.0
276.0
Available tread sizes are: 250mm, 275mm and 305mm.
Information required to detail stairs:
RVK connectors are NOT to be used in Class 2B or Class 3 buildings.
Finished floor to floor heights, number of risers, overall stairwell
Holes for handrails can be drilled on site by others a minimum of
size, width of flights, widths of landings, span directions,
50mm to the edge of the hole from the edge of the flight, and to a
support details.
Attached landing
Variable range of sizes
to specification
maximum of 100mm deep if central to the going.
8
9
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
TYPICAL
TYPICAL
CONFIGURATIONS
CONFIGURATIONS
STAIRCASE TYPE A
STAIRCASE TYPE C
Section A
Section C
Applied finish to landing
02
Applied finish to landing areas
Applied finish
to landing
When flight sits
directly on ground
slab, dowels to be
sited drilled and fixed
Dowel
PC Landing
PC Landing
PC Landing
PC Landing
PC Landing
C
A
Wall bearings
Bison support angle
STAIRCASE TYPE D
Bison support angle
Wall bearings
Section D
STAIRCASE TYPE B
Section B
Applied finish to landing
Applied
finish to
landings
When flight sits directly on
ground slab, dowels to be
Wall
bearings
sited drilled and fixed
Bison support
angle
Dowel
B
D
Wall bearings
10
11
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
TYPICAL
TYPICAL
STAIR CONNECTION AND BEARING CONDITIONS
STAIR CONNECTION AND BEARING CONDITIONS
GROUND FLOOR - NO SCREED
ATTACHED LANDING - BEARING ON MASONRY
02
25mm Nominal
25mm Nominal
50mm min.
15mm bed
16m ø douch, at 200mm from the edge, completed on site
ATTACHED LANDING - ON STEELWORK
GROUND FLOOR - SCREED
50mm min.
25mm Nominal
25mm Nominal
15mm bed
SHORT ATTACHED LANDING - ON MASONRY
100mm
HALF LANDING/FLOOR LEVEL - WITH SEPARATE PC LANDING
50mm min.
25mm Nominal
Min 200mm Bearing
Upper landing
SHORT ATTACHED LANDING - ON MASONRY
25mm Nominal
50mm min.
Lower landing
Min 100mm Bearing
12
13
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
TYPICAL
STAIRCASE AND LANDING
STAIR CONNECTION AND BEARING CONDITIONS
DISPROPORTIONATE COLLAPSE DETAIL
BEARING ON STEEL - WITH METAL DECK FLOORS
FLIGHT ATTACHED TO LANDING - HEAD AND FOOT
275mm min
50mm min.
02
HEAD
25mm Nominal
140mm
160mm min.
50mm min.
FOOT
SUPPORT WALL (OR STEEL) - WITH HOLLOWCORE SPANNING PERPENDICULAR
25mm Nominal
Last riser to be formed in
CONNECTION DETAILS - BETWEEN FLIGHT AND LANDING
finishes on site by others
100mm
GROUND FLOOR - DEEP SCREED
Sand/cement screed by
150x150x15RSA S275
others reinforced over angle
cast into stair flight c/w
with mild steel wrapping
100x100x10 flat plate
fabric or polypropylene
welded into RSA as
fibre to minimise risk of
shown on plan
shrinkage/cracking
150mm min.
10mm
10mm shim
75mm
Packer to be
173mm
placed under
Engineering brick packer by others
15mm
welded tab
before bolt is
16mm ø excalibur screw bolt site
screwed in
drilled into PC landing (only in
progressive collapse detailing)
HEAD DIMENSION - WITH STEEL SUPPORT
PC landing
160mm min. to U/S to angle
350mm min.
14
15
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
PRECAST STAIRS AND LANDINGS
SECTION
STAIRCASE AND LANDING
STAIRCASE
CONNECTION DETAILS
LIFTING GUIDELINES
STEEL SUPPORTS AND PRECAST FLIGHTS
Lifting pins are cast into the precast structure during manufacture to make on-site placing safe, quick and easy.
02
Section Y
Screed
PC depth
2 number studs
required per flight
254x146 UB 31
welding of studs and
concreting all by others
at no cost to Bison
110 pocket
Y
100 pocket
Connection details between steel supports and
By removing the need for running chains underneath the staircase structure, the risk of damage to the product is
precast flights/landings that satisfy disproportionate
collapse criteria.
254x146 UB 31
significantly reduced.
40mm
ALTERNATIVE BEARING TIE DETAIL
INTERMEDIATE QUARTER LANDING DETAIL
RC wall
50 min screed
0m
0m
m
20
25
m
50 min screed
Min. 150x150 RSA
+ stud fixed to wall
Masonry or steel
by others
support by others
N.B. Angles bolted to masonry are unsuitable
bearings for precast units
Landing units to be provided with
proprietary lifters only where they have
finished top surfaces and are being fixed by
BISON. If the landing is to receive finishes or
is fixed by others, standard lifting hooks are
provided in accordance with normal practice.
16
17
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
BUILDING REGULATIONS
SECTION
03
DIMENSIONAL REQUIREMENTS
HEADROOM
The dimensional requirements for all staircases are set out in the Building Regulations Approved Document K. The Building
Bison precast staircases conform to all current regulations and can accommodate most architectural layouts. Design and
Regulations require that flights of stairs should have all the same rise and going within the dimensional requirements shown below.
manufacture is carried out in accordance with BS 8110: 1997.
The requirements for the three categories of stair considered in the Building Regulations Approved Document K and that for
Generally stairs are cast in engineered steel moulds giving a Type ‘A’ finish*. Landings can be cast integral with the stair
disabled people in Approved Document M are as follows:
flights or separate in order to achieve the optimum staircase construction.
When balustrades are required, it is recommended that fixings for these are drilled on site. A minimum of 50mm should be
APPLICABLE
CODE
CLAUSE
RISER
RANGE
CLAUSE
GOING
RANGE
CLAUSE
MAX. NO
RISERS
CLAUSE
MIN.
WIDTH
CLAUSE
MAX.
RECEDE
GENERAL
USAGE
PART M
DISABLED ACCESS
INTERNAL STAIRS
3.51c
150-170
3.51d
Min. 250
3.51b
12
(exception
ally 16)
3.51 &
1.33
900
3.51 &
1.33j
25
All Flats
6.17
Max. 1.8m
high
allowed between the edge of the concrete and the edge of any pocket or fixing.
Bison are specialists in staircase design and you are invited to discuss requirements with us so that the most efficient and
economic staircase design can be achieved.
MEASURING HEADROOM
PART M
DISABLED ACCESS
EXTERNAL STAIRS
6.17d
BS8300
8.1.1
75-170
6.17e
Min. 280
6.17a
1200
Diag. 27
15-25
All Flats
Minimum headroom
150-170
8.1.1
250-300
preferred
at 300
8.1.2
12 (small
premises
16)
n/a
none
given
8.1.1
25 Max.
- square
preferred
Pitch line
All Flats
At least 2m
DDA (DISABLED
DISCRIMINATION
ACT)
Fig 18
150-170
Fig 18
280-425
Fig 18
12r
<350go
16r>350g
Fig 18
25 Max.
- square
preferred
Fig 18
1200
All Flats
n/a
none
given
1.8
Min. 16
Single Flats
At least 2m
Landing
At least 2m
PART K
GENERAL USE
PRIVATE
1.3a
165-220
1.3a
223-300
1.4
Max. angle
42 deg
PART K
GENERAL USE
INSTITUTION/
ASSEMBLY
1.3b
135-180
1.3b
280-340
1.4
Max. angle
38 deg
n/a
none
given
1.8
Min. 16
Schools
Colleges
Libraries
Halls etc.
PART K
GENERAL USE
OTHER
1.3c
150-190
1.3c
250-320
1.4
Max. angle
38 deg.
n/a
none
given
1.8
Min. 16
Offices & all
other build
Flight
Landing
MEASURING RISER AND GOING
Going
Top surface of tread
Riser
*Other finishes available on request.
18
19
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
SPECIFICATION DETAILS
1.0 SCOPE OF THE SPECIFICATION
SECTION
3.04 Fire: Fire resistance is based upon the tabulated data
1.01 Relates to: This specification covers the design, manufacture
and associated site work of the following types of stairs:
• Reinforced Concrete stairs
1.02 Description of stairs
drilled on site by others to suit individual requirements. A
Bison precast units are to be provided by others. These
available for fire periods of 1 hour or 2 hours without the
minimum dimension of 50mm, 75mm preferred, should
should generally be 100mm for concrete and masonry
addition of further finishes. This period of fire resistance may
be allowed between the edge of a pocket of fixing and the
and a minimum of 75mm for steelwork, but subject to the
be further enhanced by the application of appropriate finishes.
edge of the concrete and to a maximum depth of 100mm
requirements of clause 5.2.3 of BS 8110:1997.
4.06 Lifting points: These will be provided in the factory as
by the Engineer with the responsibility for the design of the
overall structure in accordance with the relevant Codes of
2.03 Admixture: Concrete used is of a self compacting nature,
and therefore does contain some additives. This additive is
to provide adequate suspension in our mix to achieve the self
levelling nature of the concrete.
2.04 Reinforcement: Reinforcement for reinforced precast stairs
is generally high yield, high bond bars complying with the
requirements of BS 4449:2005 and is detailed in accordance
with BS 4466 unless specified.
screed finish applied with a suitable bonding agent.
4.01 Method of Manufacture: Bison standard precast stairs are
3.02 Service Class: The design of Bison reinforced concrete stair
units is to Serviceability classification, Class 3 with a limiting
crack width of 0.1mm, and RC stair units to 0.3mm crack
width.
3.03 Durability: The standard Bison stair is designed to comply
the design capacity of the staircase.
cement screed added so as to allow for manufacturing
Kingdom patent numbers 2193922 and 2217359. Other stairs
tolerances. Due to this requirement, the top step contains
are to be filled and made good by others, when erection
to suit specialist requirements may be made using ramp
a recess thus creating a screed stop – see Bison general
is complete.
moulds with timber stringers and risers.
arrangement drawings. Separate reinforced landings are
also available. These also are to be used in conjunction
4.02 Mould: The design of the mould is such that any riser
height within the range of 150mm to 210mm is available.
Alternative tread dimensions of 250mm, 275mm and 305mm
of the receding riser (all Bison standard moulds have a
systems are available for direct fixing to concrete and we
and to cover up the support angle cast in to the Bison
shall be pleased to offer recommendations on request.
4.09 Angles: Purpose made angles may be provided at
the end of flights or stairs to bear onto other concrete
with the riser dimension as shown in the table. To achieve
members such as landings or beams. The design of these
the economic benefits in offering Bison standard precast
is subject to strict limits and may require that additional
staircases, it is assumed that minor modifications can be
support is provided.
moulds which are of timber manufacture. The maximum length
of the Bison standard staircase is 11.00m. However the length
of the stair may be restricted due to the weight considerations
during manufacture and this is set at maximum of 10 tonnes.
5.05 Soffit fixings: Several fast and cost effective proprietary
with a screed again to allow for manufacturing tolerances
nominal 25mm recede). Thus the going varies very slightly
up to 2.40m wide. Special widths may be provided using ramp
5.05 Lifting sockets: All sockets formed for lifting purposes
flights.
are available. These are fixed dimensions, as is the angle
4.03 Dimensions: Bison Standard staircases may be manufactured
“The Structural Use of Concrete”.
may be drilled on site. Larger holes may be cut subject to
manufactured in precision engineered steel moulds United
6.0 QUALITY MANAGEMENT SYSTEM
6.01 QMS Reference: Bison are members of the BSI
Registered Firm Scheme for Quality Management Systems
to BS EN ISO 9001:2000 for the design, manufacture and
installation of precast products.
DESIGN
requirements and recommendations of BS 8110:1997
5.04 Holes and Cutouts: Small holes up to 60mm diameter
landings and these must have a minimum of 50mm sand/
standard units.
3.01 Code: The design of Bison units is in accordance with the
temporary propping that may be required.
4.08 Landings: Bison can supply flights with attached
made to the stairwell dimensions to accommodate the
3.0 on our working drawings details and duration of any
clause 6.2.7.3 of BS8110:1997. The treads and risers are
MANUFACTURE
2.02 Concrete: The design strengths of concrete used in the
• Ultimate Concrete Strength is a minimum of 50 N/sq.mm.
authority within the Bison organisation. We shall specify
suitable for the direct application of carpet or tiles or for a
4.0 permission has been obtained from a competent technical
string is to a Type A finish (minimum)* as described in
ends as per Bison standard details.
appropriate British Standard and this specification.
Reinforced Design
measures are unavoidable, fixing must not progress until
Concrete surface finish to soffit, treads, riser and one
2.01 Standards: All materials are to be in accordance with the
shall be avoided wherever possible. In cases where such
an engineered steel mould face giving excellent quality.
2B structures and greater, generally stairs are tied at bearing
design and manufacture of Bison units is as follows:-
bearings (i.e. head trees and bearers, etc.) this practice
side, all surfaces with the exception of one string are from
Practice. To accommodate tie details, a C40 structural topping
MATERIALS
specifically allows for units to seat onto temporary
4.07 Finishes: The Bison Standard staircase is cast on its
may be required in lieu of screed zones. To comply with class
2.0 5.03 Temporary Bearings/Propping: Unless the design
proprietary inserts to be made good on site by others.
requirements for accidental damage should be specified
reinforced precast stairs.
5.02 Bearings: Level and structurally adequate bearings for
contained within BS 8110 : Part 2 Section 4. Sections are
3.05 Horizontal and Vertical Ties: Ties necessary to satisfy the
• The precast stairs are designed and manufactured as 4.05 Balustrade Fixings: It is recommended that these are
04
5.0 SITE WORK
5.01 Standard: All site work is to be undertaken in accordance
6.02 Scope: Membership of the scheme ensures that
all processes relevant to the design, manufacture
and installation of precast products, are subject to
with the best current practice and Health & Safety
independent review and approval by the British Standards
legislation. For further advice reference should be made
Institution.
to the “Code of Practice for the Safe Erection of Precast
Concrete Flooring”.
4.04 Permitted Deviations: Cross-sectional tolerances are within
the limits set out in clause 6.2.8.3 of BS 8110:1997. Erection
tolerances are as per BS5606.
with the durability requirements of BS8500:2006.
*Other finishes available on request.
20
21
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
HEALTH AND SAFETY
SAFETY DO’S & DON’TS
SECTION
05
HEALTH AND SAFETY PRODUCTS
GUIDELINES
SAFETY DO’S & DON’TS
The do’s & don’ts listed below are by no means fully exhaustive, you should also refer to the current issue of the Precast
Flooring Federation Code of Practice available on Tel: 0116 253 6161.
Health and Safety is a major concern for Bison, and we have developed a range of methods and systems which help to
ensure that anyone using Bison products can do so with minimal risk to themselves or others.
•
Do not alter the product without written permission from Bison Design Office, altering the product may compromise
its structural integrity and lead to failure. This includes notching, hole forming, shortening, narrowing the unit etc.
•
Do not alter the product in-situ, any permissible alterations must be completed on a flat stable platform. i.e. on the
ground or floor area.
•
Do not allow anyone to walk or work beneath the product whilst it is being hoisted or suspended.
•
Do not work in areas without the appropriate perimeter edge protection, handrails, guardrails, platforms or stages.
•
Do not access working areas without properly constructed, maintained, secured and illuminated, stairways, ramps,
ladders or the like.
•
Where lifting hooks are specified within a contract, do hoist the units by crane using ALL the lifting points in the top
surface provided for that purpose. Prior to lifting safety chains must be loosely slung around the underside of the
unit. The safety chains may only be released immediately before the slab is placed in its final position.
•
For insurance purposes, Bison do not supply or hire lifters or chain sets. Please refer to our information sheets for
details of supplier hire or purchase.
•
Do not run plant or store equipment on the precast floor before it is grouted and cured. Once cured do not exceed
the loads specified by the engineer.
•
Do use a passive fall protection system wherever reasonably practicable considering all heights where the potential
fall distance could result in an injury.
•
Do ensure the perimeter scaffolding is positioned no more than 900mm below the top surface of the flooring, or landing level.
•
Do ensure all voids created whilst placing units are adequately protected during and after erection.
•
Do ensure all brickwork, blockwork or concrete is adequately cured, stable and fit to receive precast concrete units,
and that steelwork is stable.
•
Do ensure the stability of support beams, lintels etc. is considered, particularly the rotation of support member due
to unequal loading.
parapet and corner mats can be provided.
•
Do ensure you include allowance for site handling by referring to the unit weight table.
Hole Covers
•
Do ensure that all lifting equipment is supplied, used and inspected in accordance with current legislation.
Voids such as service holes, formed in precast floor units
•
Do ensure all lifting operations are completed and in accordance with current legislation.
are trip hazards and have the potential to cause serious
•
Do wear adequate personal protective equipment (PPE) whilst handling or cutting concrete.
injuries. Bison’s solution is the Hole Filler: a strong yet
Trailasafe®
Trailasafe® is designed to prevent or mitigate injuries
resulting from falls from trailer decks. Comprising
synthetic mesh suspended from a series of brackets
housing support arms, the system arrests the fall of
personnel, absorbing the energy of their descent and
ensuring their safety. Fully demountable, the system can
be stored within the vehicle or at the unloading point.
THE BISON AIR MAT
The Bison Air Mat system has been tested by the BRE
and approved by the HSE. The Bison Air Mat system
comprises a series of interconnected and interlinked
mats available in a wide range of standard sizes. Using
a combination of modules they will accommodate
almost any floor area. Where the edges of an area to be
protected are open, or have large vertical voids that may
pose the hazard of “roll-off” fall to a lower area, special
slimlined product which is suitable for most holes.
NOTE; Due to the principle constituents of cement, the liquid released whilst drilling drainage points etc is likely to
have a caustic effect on the eyes and skin. For further information or to obtain the latest issue COSHH data sheet for
cement call our Health & Safety Department at our Burton office Tel 01283 495000.
The yellow, anti-slip cover is fully reusable and comes in
two sizes, 250mm or 350mm square. Each may be either
screwed down or fitted without the need for power tools,
by spreading the unit legs, locking it into position.
22
23
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
DESIGN SOLUTIONS
SECTION
DESIGN
DESIGN
SERVICES
GUIDANCE
06
Bison’s in-house design experts
are up to speed on all governing
legislation to ensure compliant
products are manufactured using
modern methods of construction.
SPEED ON DESIGN
DESIGN SUPPORT
Bison has invested heavily in its design services,
Bison’s in-house team represents the very best in the
ensuring customers can take advantage of the most
industry and is on hand to give design advice for any
appropriate, value-engineered solution for their project.
project, large or small. They can help identify the optimal
Involvement at the earliest stages of a project enables
solution for your project, whether this means using one
Bison to design-out some of the issues that can become
of our many precision-made steel moulds, or taking the
apparent on-site during the later stages of the build.
bespoke approach with a custom-made casting.
SPEED ON TECHNICAL SUPPORT
Bison’s unrivalled technical support service offers
Modern Methods of
Construction (MMC)
Part A
Modern Methods of Construction encompasses a variety of
a system of classification of buildings to reflect the risk of
off-site building techniques. MMC can help to improve build
disproportionate collapse probabilities. Bison’s in-house
quality, reduce time and waste on site and raise safety levels.
experts can offer advice on the details required for each of
At Bison, we have developed leading technology, enabling us
the main frame options related to reinforced concrete stairs.
The Building Regulations Part A, December 2004, introduced
to supply wall panel, stadia and frame components.
Part K
Part L and the Energy
Performance of Buildings
Approved Document Part K of The Building Regulations
In use, Bison precast concrete offers thermal capacity which
impacts of stairs, ladders and ramps, with particular
2000 calls for the protection of falls, collisions and
can be used for active Fabric Energy Storage (FES), that
focus of the design, construction and use of such
Designs are produced in our centralised production
can reduce carbon emissions from a building by up to 50%
products. As market leaders in the precast concrete
planning department and downloaded to the factory
by reducing the need for air conditioning. Using FES makes
industry, Bison has unrivalled experience in producing
machines by wireless link.
good long-term financial sense for occupants who benefit
both standard and bespoke products that work to deliver
from reduced energy bills.
the requirements of industry legislation.
dedicated assistance at every stage of a project. We
The Bison Precast Floor Designer software can assist with
have gathered a wealth of knowledge and expertise since
the design of many Bison products including Hollow Core
our formation in 1919 and we are proud to lead the way in
slab units, Composite Hollowcore slab units and Solid
customer service.
Composite slab units.
24
25
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
SERVICE AND DELIVERY
SECTION
07
RESOURCE
SERVICE
AND CAPACITY
AND DELIVERY
The largest production capacity across three manufacturing plants throughout the UK, with Certificates of Assessed Capability,
SPEED ON SERVICE
SPEED ON DELIVERY
The Bison service team provide comprehensive support,
Once products are manufactured and cut to shape, they
from estimating to production and a contract team who
are loaded onto delivery pallets in the sequence required
install the products on-site. No matter where you are
for on-site erection. This improves construction and
located in the UK, Bison’s nationwide coverage ensures
handling time on-site.
awarded by the British Standards Institution.
that support is never far away.
INNOVATION
Over the last seven years, Bison has invested £50 million
to ensure that our customers continue to benefit from
innovative approaches to production, installation and service.
We can boast a number of unique developments such as
mechanically inserted Lifting Hooks and the Trailasafe® fall
arrest system.
NATIONAL COVERAGE
Bison’s three manufacturing sites across England and
Scotland ensure that customers from across the UK can
take advantage of our renowned support and service.
UDDINGSTON
LEEDS
SWADLINCOTE
26
27
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
SERVICE AND MANUFACTURING
SECTION
08
Sustainability
With Bison products, you can be certain that all materials have been produced in conditions designed to have as little impact
on the environment as possible. Swadlincote is the most environmentally friendly factory of its kind in the world.
www.bison.co.uk
For further information on Bison Precast Concrete Flooring and the full
range of Bison products and services, visit www.bison.co.uk or call the
Bison sales team on 01283 495000
Customer Driven
Customer SERVICE
Our investment is focused on meeting and exceeding
The Bison service team provide comprehensive support,
customer expectations. Bison customers in all the sectors
from estimating to production and a contract team who
we serve know that they can rely on us for outstanding
install the products on site. Wherever you are in the UK,
technical support, reliability and the highest quality product.
Bison’s nationwide coverage ensures that support is
never far away.
FLOORS • FRAMES • STADIA • STAIRS • HEALTH & SAFETY
28
29
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
NOTES
SECTION
08
30
31
For EXTENSIVE TECHNICAL DETAILS PLEASE VISIT our website: www.bison.co.uk
For further HELP AND INFORMATION PLEASE CALL OUR TECHNICAL HELP LINE: 01283 495334
BISON CONCRETE
PRODUCTS Ltd
Millennium Court,
First Avenue, Centrum 100,
Burton-Upon-Trent
DE14 2WR
Telephone: 01283 495000
Facsimile: 01283 544900
Email: [email protected]
Web: www.bison.co.uk
OTHER BROCHURES
AVAILABLE
• Concrete Flooring
• Stadia Products
• Crosswalls
• Safety Systems
Printed on 100% recyclable paper
using vegetable based inks
September 2008
All dimensions and illustrations in this publication are intended for guidance only and shall not constitute a “sale by description”.
All dimensions given are nominal and Bison Limited may modify and change the information, products and specifications from time
to time for a variety of reasons without prior notice. The information printed in this publication at the time of going to print, to the
best of our knowledge, is correct and is not intended to have any legal effect, whether by way of advice, representation or warranty
(express or implied). We accept no liability whatsoever (to the extent permitted by law) if you place any reliance on this guide you
must do so at your own risk.
All rights reserved. Copyright in this publication belongs to Bison and all such copyright may not be used, sold, copied or
reproduced, in whole or part, in any manner or in any media to any person without prior written consent.