Series - Mitsubishi Electric

Transcription

Series - Mitsubishi Electric
More than Air Conditioning
Catalogue
2004/2005
Air Conditioning Program
R 407C
R 410A
MITSUBISHI ELECTRIC
Air Conditioning Systems
As one of the world’s leading technology companies,
MITSUBISHI ELECTRIC is committed to providing
products and solutions which will enhance the quality
of our lives – at home, at work and at play.
Our outstanding range of split and multi-split air
conditioning systems reflect this philosophy.
Whether you are an installer, specifier or user, you will
appreciate the combination of quality, energy-efficiency,
reliability and ease-of-installation that MITSUBISHI
ELECTRIC Environmental Control products offer.
New technology, more comfort, more
energy-efficiency - high-quality air conditioners
of MITSUBISHI ELECTRIC!
Product series
The program offers you more choice than ever before.
So whatever the application - a shopping centre, a hotel,
restaurant, shop or even a domestic home - the different
product series provide the optimum fit.
In-ceiling cassettes
Contents
Units of the M Series are designed for smaller rooms, each
outdoor unit requires up to 4 indoor units.
The Mr. Slim Series is applied for middle-sized rooms and is
available as single-split and as multi-split system in parallel
mode.
M-Series
Wall mounted systems
The City Multi Series convinces with cooling capacity of
14 kW till 84 kW in a refrigerant cycle used for big projects.
New technology
The inverter technology and new refrigerant R410A enable
more energy efficiency. All indoor units can be controlled
separately for customised adjustment of temperature.
Easy installation
The environment-friendly systems of MITSUBISHI ELECTRIC
can be installed with minimum work. Space-saving and
compact units are available for wall or floor mounting for a flexible planning and design of structures. The air
conditioning systems are expandable for subsequent
increasing of the capacity at any time.
24
Mr. SlimR407C-Series 26
Floor standing units
Ceiling suspended systems
Rating conditions
COOLING Indoor: 27°C DB / 19°C WB
Outdoor: 35°C DB / 24°C WB
Outdoor water temperature for WR2 30°C
HEATING Indoor: 20°C DB
Outdoor: 7°C DB / 6°C WB
Outdoor water temperature for WR2 20°C
Refrigerant piping length 5 m / 7.5 m* (one way)
H = 0 m
Sound pressure level measured in anechoic
room, at a position 1 m in front of the outdoor unit
* For PUH-P8/10MYA and City Multi
M-Series
Accessories
4
Mr. SlimR410A-Series 62
Power Inverter
Mr. SlimSeries
Accessories
70
City MultiSeries
74
City MultiSeries
Accessories
88
Lossnay
Ventilation
Series
94
Dehumidifier
Above ceiling concealed
ducted systems
3
98
M Series
Split- and Multi-Split Systems
Cooling 2.3 kW - 8.5 kW
The outstanding M Series brings legendary Mitsubishi
Electric quality to the low-capacity air conditioning class.
M Series units are perfect for small living spaces like offices, restaurants and small shops, where their unobtrusive
appearance and quiet operation are important advantages.
Ultra-energy-efficient
M Series systems are designed to give lowest possible
running costs, with innovative energy-saving features
like `Econo-Cool´, which direct airflow towards room
occupants. This can allow set temperatures to be raised
by 2°C with no loss in comfort and a 20% gain in energy
efficiency.
4
Lowest noise levels
With noise levels down to just 21 dB(A)
Excellent control features
M Series remote controllers incorporate easy-to-use
features like `IFeel´ control, which memorises the user`s ideal temperature and recreates it precisely.
Multi-splits
The M Series includes split system models, running up to four indoor units from one outdoor unit.
Plus ...
● Optional high-efficiency air
cleaning filters; deodorising
and antibacterial Catechin
filters available for wallmounted systems
● Rapid room cooling with
swing mode feature
● Remote control of five
different angles of airflow
to reach ideal temperatures
in optimum time
●
A wide range of indoor units
and dual-use units for either
floor or ceiling installation
● Quick and easy installation
● Auto restart function
● Winterkit in cooling mode
up to -15°C for inverter
models and a wind-protected
installation
Range of M Series
● Cooling Indoor:
21° - 32°C DB
15° - 23°C WB
Outdoor: 21° - 43°C DB Non-Inverter models and
MXZ-A18 WV
-15° - 43°C DB Inverter types
● Heating Indoor:
20° - 27°C DB
Outdoor: - 9° - 21°C DB
-10° - 15°C WB
MSC Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MS Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
MSC Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
MSH Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
MCF Cooling Only Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
MCFH Cooling/Heating Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . 11
MSZ Inverter Single Split Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . 12
SLZ Inverter Cooling/Heating 4-Ceiling Cassette Systems. . . . . . . . . . . . . . . . . . . . . . . . 14
SEZ Inverter Cooling/Heating Ceiling Concealed Systems . . . . . . . . . . . . . . . . . . . . . . . 15
MSX Multi Split Systems Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
MXZ Inverter Multi Split Systems Cooling/Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
M SERIES Accessories/Optional Parts/Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5
Series MSC Cooling Only
Wall Mounted Systems
●
Energy-saving rotary piston
compressor
● Extremely quiet operation with
noise level of only 25 dB(A)*
● `Swing Mode´-function enables automatically a more natural and comfortable airflow
throughout the room
● Factory charged with refrigerant R410A
● Hand-held controller with `fuzzy logic´ control
● Remote control for five different angles of airflow direction
●
Auto restart function
24 h Timer
● Long-life and washable Catechin filters for deodorising
and prevention of bacteria
and viruses
●
Accessories:
Additional filters available
to keep air fresh, please view
page 24
* MCS-A07/09YV
MSC COOLING ONLY - WALL MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Low
High
Low
High
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER CONSUMPTION (kW)
Cooling
MAX. PIPE LENGTH
MAX. HEIGHT DIFFERENCE
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
MSC-A09YV
2.55
306
474
25
36
9
815
244
278
Width
Depth
Height
(m)
(m)
(kg)
Liquid
Gas
0.17
MU-A07YV
0.17
MU-A09YV
0.715
0.795
1.14
1686
1686
1914
45
34
780
255
540
20
10
0.60
6
10
45
34
780
255
540
20
10
0.60
6
10
49
36
780
255
540
25
10
0.75
6
12
0.19
MU-A12YV
220-240, 1, 50
3.00
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m
in front of and 0.8 m below the unit in anechoic chamber
6
MSC-A12YV
3.5
324
582
26
40
10
815
244
278
220-240, 1, 50
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MSC-A07YV
2.3
276
474
25
36
9
815
244
278
3.32
4.92
Series MS Cooling Only
Wall Mounted Systems
●
Energy-saving rotary piston
compressor
● Compact indoor units - easy
to install
● `Swing Mode´-function
enables automatically a more
natural and comfortable
airflow throughout the room
● Factory charged with
refrigerant R410A
● Hand-held controller with
`fuzzy logic´ control
● Remote control for five
different angles of airflow
direction
●
Auto restart function
24 h Timer
● Long-life and washable
Catechin filters for
deodorising and prevention
of bacteria and viruses
●
Accessories:
Additional filters available
to keep air fresh,
please view page 24
MS COOLING ONLY - WALL MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (KW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (MM)
MAX. PIPE LENGTH
MAX. HEIGHT DIFFERENCE
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A))
Cooling
Low
High
Low
High
Width
Depth
Height
MS-A18WV
5.0
528
768
34
42
16
1100
227
325
MS-A24WV
6.5
588
768
37
45
16
1100
227
325
MS-A30WV
8.5
684
960
37
47
16
1100
227
325
220-240, 1, 50
0.30
MU-A18WV
Cooling
Width
Depth
Height
(m)
(m)
(kg)
Liquid
Gas
0.30
MU-A24WV
0.34
MU-A30WV
1.81
2.48
3.26
2196
2760
2940
52
44
850
290
605
25
10
1.40
6
12
53
60
850
290
605
25
10
1.90
6
16
55
85
840
330
850
30
15
2.30
10
16
220-240, 1, 50
7.93
10.39
14.42
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and
0.8 m below the unit in anechoic chamber
7
Series MSC Cooling/Heating
Wall Mounted Systems
●
True comfort year-round
Compact indoor units easy to install
● Extremely quiet operation with
noise level of only 25 dB(A)*
● `Swing Mode´-function
for a quick cooling and
comfortable airflow throughout the room
● Energy-saving rotary piston
compressor
● Factory charged with
refrigerant R410A
●
●
Hand-held controller with
`fuzzy logic´ control
● Remote control for five
different angles of airflow
direction
● Auto restart function
● 24 h Timer
● Long-life and washable
Catechin filters for
deodorising and prevention
of bacteria and viruses
Accessories:
Additional filters available
to keep air fresh,
please view page 24
* MSC-A07/09YV
MSC COOLING/HEATING - WALL MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER CONSUMPTION (kW)
Width
Depth
Height
MSC-A07YV
2.3
2.5
276
474
25
36
9
815
244
278
Cooling
Heating
0.17
MUH-A07YV
0.715
0.69
0.17
MUH-A09YV
0.795
0.84
0.19
MUH-A12YV
1.09
1.08
1686
1710
1710
47
35
780
255
540
20
10
0.62
6
10
49
38
780
255
540
20
10
1.00
6
10
49
40
780
255
540
25
10
1.00
6
12
Cooling
Heating
Low
High
Low
High
MAX. PIPE LENGTH
MAX. HEIGHT DIFFERENCE
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
MSC-A12YV
3.5
3.9
324
582
26
40
10
815
244
278
220-240, 1, 50
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MSC-A09YV
2.55
3.05
306
474
25
36
9
815
244
278
Width
Depth
Height
(m)
(m)
(kg)
Liquid
Gas
220-240, 1, 50
3.00
3.32
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m
below the unit in anechoic chamber (cooling mode)
8
4.65
Series MSH Cooling/Heating
Wall Mounted Systems
●
True comfort year-round
Compact indoor units easy to install
● `Swing Mode´-function for a
quick cooling and comfortable airflow throughout the
room
● Energy-saving rotary piston
compressor
● Factory charged with
refrigerant R410A
● Hand-held controller with
`fuzzy logic´ control
● Remote control for five different angles of airflow direction
● Auto restart function
● 24 h Timer
●
●
Long-life and washable
Catechin filters for
deodorising and prevention
of bacteria and viruses
Accessories:
Additional filters available
to keep air fresh,
please view page 24
MSH COOLING/HEATING – WALL MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h))
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h))
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH
MAX. HEIGHT DIFFERENCE
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Width
Depth
Height
MSH-A18WV
5.0
5.2
528
768
34
42
16
1100
227
325
Cooling
Heating
0.30
MUH-A18WV
1.78
1.61
0.30
MUH-A24WV
2.41
2.48
0.34
MUH-A30WV
3.26
3.43
2196
2760
2940
52
47
850
290
605
25
10
1.75
6
12
53
74
840
330
850
25
10
2.15
6
16
55
87
840
330
850
30
15
2.30
10
16
Cooling
Heating
Low
High
Low
High
MSH-A24WV
6.3
7.2
588
768
37
45
16
1100
227
325
MSH-A30WV
8.5
9.4
684
960
37
47
16
1100
227
325
220-240, 1, 50
Width
Depth
Height
(m)
(m)
(kg)
Liquid
Gas
220-240, 1, 50
7.93
10.39
14.42
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in
anechoic chamber (cooling mode)
9
Series MCF Cooling Only
Floor or Ceiling Mounted Systems
●
Versatile 2-in-1 design
supplied with multi-purpose
brackets for floor-standing or
ceiling-suspension
● Hand-held controller with
`fuzzy logic´ control
● Lightweight and compact
design for easy installation
● Readily access for pipe
connections and maintenance
● Quiet operation noise
● Adjustment of five different
angles of airflow direction
●
Three fan-stages or
automatic set-up angles of
airflow direction
● `Swing Mode´-function for a
quick cooling and comfortable
airflow throughout the room
● Factory charged with
refrigerant R410A
● Auto restart function
● 24 h Timer
Accessories:
Additional filters available
to keep air fresh,
please view page 24
MCF COOLING ONLY - FLOOR OR CEILING MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HeightNDIFFERENZ (m)
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE,Hz)
RUNNING CURRENT (A)
Cooling
Low
High
Low
High
Width
Depth
Height
MCF-A12WV
3.5
474
678
34
44
25
1100
180
650
MCF-A18WV
4.8
492
780
36
46
25
1100
180
650
MCF-A24WV
6.0
642
840
42
48
25
1100
180
650
220-240, 1, 50
Cooling
Width
Depth
Height
(kg)
Liquid
Gas
0.26
MU-A12YV
0.36
MUCF-A18WV
0.39
MUCF-A24WV
1.16
1.81
2.45
1914
2196
2760
49
36
780
255
540
25
10
0.75
6
12
52
44
850
290
605
25
10
1.2
6
12
53
60
850
290
605
25
10
1.8
6
16
220-240, 1, 50
4.89
7.92
10.59
* Factory charged to 7 m pipe length, optional charging on page 25
The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below
(floor standing) the unit in anechoic chamber
10
Series MCFH Cooling/Heating
Floor or Ceiling Mounted Systems
●
Versatile 2-in-1 design
supplied with multi-purpose
brackets for floor-standing or
ceiling-suspension
● Lightweight and compact
design for easy installation
● Comfortable temperature the
whole year round
● Quiet operation noise
● Hand-held controller with
fuzzy-logic control
● Adjustment of five different
angles of airflow direction
● 24 h Timer
● Factory charged with
refrigerant R410A
●
Readily access for pipe connections and maintenance
● Three fan-stages or automatic
set-up angles of airflow
direction
Accessories:
Additional filters available to
keep air fresh,
please view page 24
MCFH COOLING/HEATING - FLOOR OR CEILING MOUNTED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW(m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW(m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE
CHARGE R410A*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
Low
Mittel
High
Low
High
Width
Depth
Height
MCFH-A12WV
3.5
3.7
492
636
780
36
46
25
1100
180
650
MCFH-A18WV
4.8
5.0
570
696
840
39
48
25
1100
180
650
MCFH-A24WV
6.0
6.8
642
744
840
42
48
25
1100
180
650
220-240, 1, 50
Cooling
Cooling
Heating
Width
Depth
Height
(m)
(kg)
Liquid
Gas
0.30
MUH-A12YV
1.16
1.02
0.36
MUCFH-A18WV
1.81
1.89
0.36
MUCFH-A24WV
2.45
2.72
1710
2196
2760
49
40
780
255
540
25
10
1.0
6
12
52
47
850
290
605
25
10
1.75
6
12
53
74
840
330
850
25
10
2.15
6
16
220-240, 1, 50
4.85
8.01
10.51
* Factory charged to 7 m pipe length, optional charging on page 25
The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing)
the unit in anechoic chamber
11
Series MSZ Inverter Single-Split
Cooling/Heating
Wall Mounted Systems
●
Compact indoor units easy to install
● Easy and quick cleaning with
`Quick Clean Body´-system
● Extremely quiet operation
with noise level of only 21
dB(A) (MSZ-A09YV)
● Energy-saving inverter
technology provides highest
comfort year-round
● `Swing Mode´-function for a
quick cooling and comfortable airflow throughout the
room
● Factory charged with
refrigerant R410A
● Hand-held controller with
`fuzzy logic´ control
●
Remote control for five
different angles of airflow direction
● 24 h Timer
● Long-life and washable
Catechin filters for deodorising and prevention of
bacteria and viruses
● Winterkit in cooling mode up
to -15° C, view page 5
Accessories:
● Additional filters available to
keep air fresh,
please view page 24
● Quick clean kit for connection to household vacuum
cleaner
MSZ INVERTER SINGLE-SPLIT, COOLING/HEATING
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW(m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MSZ-A09YV
2.5 (0.9 - 3.2)
3.2 (0.9 - 5.0)
222
504
21
37
9
815
244
278
Cooling
Heating
0.17
MUZ-A09YV
0.67
0.84
0.19
MUZ-A12YV
1,09
1.08
1900
1900
46
33
800
285
550
20
12
0.80
6
10
47
34
800
285
550
20
12
0.90
6
10
Cooling
Heating
Low
High
Low
High
MSZ-A12YV
3.5 (1.0 - 4.1)
4.0 (0.9 - 6.0)
288
630
22
39
10
815
244
278
220-240, 1, 50
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A*
(kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
220-240, 1, 50
3.3
5.0
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m
below the unit in anechoic chamber (cooling mode)
12
Series MSZ Inverter Single-Split
Cooling/Heating
Wall Mounted Systems
●
Compact indoor units easy to install
● Easy and quick cleaning with
`Quick Clean Body´-system
● Energy-saving inverter
technology provides highest
comfort year-round
● `Swing Mode´-function for a
quick cooling and comfortable airflow throughout the
room
● Factory charged with
refrigerant R410A
● Hand-held controller with
`fuzzy logic´ control
● Remote control for five
different angles of airflow
direction
●
24 h Timer
Long-life and washable
Catechin filters for
deodorising and prevention
of bacteria and viruses
● Winterkit in cooling mode up
to -15° C, view page 5
●
Accessories:
Additional filters available
to keep air fresh,
please view page 24
MSZ INVERTER SINGLE SPLIT, COOLING/HEATING
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MSZ-A18YV
5.0 (0.9 - 5.9)
6.25 (0.9 - 7.8)
486
828
32
47
16
1100
258
325
Cooling
Heating
0.3
MUZ-A18YV
1.56
1.73
0.3
MUZ-A24YV
1.99
2.05
0.34
MUZ-A26YV
2,35
2.65
2940
2940
2940
55
72
840
330
850
30
15
1.80
6
12
55
72
840
330
850
30
15
2.20
6
16
55
80
840
330
850
30
15
2.35
10
16
Cooling
Heating
Low
High
Low
High
MSZ-A24YV
6.0 (0.9 - 6.7)
7.0 (0.9 - 8.1)
510
1020
33
47
16
1100
258
325
MSZ-A26YV
7.1 (0.9 - 8.1)
8.5 (0.9 - 9.5)
552
1020
33
47
16
1100
258
325
220-240, 1, 50
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A*
(kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE,Hz)
RUNNING CURRENT (A)
220-240, 1, 50
6.9
8.8
11.0
* Factory charged to 7 m pipe length, optional charging on page 25
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below
the unit in anechoic chamber (cooling mode)
Units available approx. July/August 2004
13
Series SLZ Inverter
Cooling/Heating
In-Ceiling Cassette Systems
●
The standardised Euro-spacing ● Equipped with drain pump,
facilitates installation in existing
delivery height 500 mm
inserted ceilings
● Fresh air intake
● The required installation height
● Infrared controller with
is only 235 mm
12-hours on/off-timer
● Quiet operation with noise level ●
Auto restart function
of only 32 dB(A)*
● Factory charged with R410A
● Low weight of 16.5 kg - easy
● Winterkit in cooling mode up
to install
to -15° C, view page 5
● Best airflow adjustment by
three fan stages
* SLZ-A09AR
● Long-life filters to keep air
fresh, cleaning necessary only
after 2,500 hours of normal
operation
SLZ INVERTER COOLING/HEATING - IN-CEILING CASSETTE SYSTEMS
INDOOR UNIT
GRILLE
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (KG)
DIMENSIONS (mm)
Indoor unit
DIMENSIONS (mm)
Grille
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Heating
Low
Middle
High
Low
High
(kg)
Width
Depth
Height*
Width
Depth
Height**
SLZ-A09AR
SLP-2AL
2.5 (0.9 - 3.2)
3.0 (0.9 - 3.7)
480
540
600
32
38
16.5/19.5
570
570
235
650
650
20
SLZ-A12AR
SLP-2AL
3.2 (1.0 - 4.1)
3.8 (0.9 - 4.8)
540
600
660
34
39
16.5/19.5
570
570
235
650
650
20
Cooling
Heating
0.4
SUZ-A09VR
0.76
0.87
0.6
SUZ-A12VR
1.06
1.07
0.62
SUZ-A18VR
1.53
1.50
1900
1900
2940
46
33
800
285
550
20
12
0.8
6
10
47
34
800
285
550
20
12
0.9
6
10
55
72
840
330
850
30
15
1.4
6
12
220-240, 1, 50
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A***
(kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
220-240, 1, 50
3.7
*** Required installation height
*** Visible height of grille
*** Factory charged to 7 m pipe length, optional charging on page 25
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber (cooling mode)
14
SLZ-A18AR
SLP-2AL
4.3 (0.9 - 5.0)
4.8 (0.9 - 5.6)
540
600
660
35
40
16.5/19.5
570
570
235
650
650
20
4.9
7.4
Series SEZ Inverter
Cooling/Heating
Ceiling Concealed Systems
●
Quiet operation of indoor and
outdoor units
● Compact, easy-to-install
design (only 270 mm height)
● Low power consumption for
economy of use
● Direct driven, forward curved
centrifugal fan for maximum
air throw
● Self diagnostic trouble
shooting function
● Air intake options for entry at
back or base of indoor unit
●
High quality remote control
with service display and
12 h-timer
● Factory charged with
refrigerant R410A
● Auto restart function
● Winterkit in cooling mode up
to -15°, view page 5
● Air filters PAC-1000 FT
included in delivery
SEZ INVERTER COOLING/HEATING - CEILING CONCEALED SYSTEMS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
Cooling
Heating
Low
High
EXTERNAL STATIC PRESSURE (Pa)
NOISE dB(A)
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
3
AIRFLOW (m /h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE* R410A
(kg)
PIPE SIZE
Liquid
Gas
Ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
SEZ-A12AR
3.4 (1.0 - 4.3)
3.9 (0.9 - 4.9)
600
780
SEZ-A18AR
4.7 (0.9 - 5.6)
5.7 (0.9 - 6.6)
720
1020
SEZ-A24AR
5.4 (0.9 - 6.1)
6.5 (0.9 - 7.4)
720
1200
30 (50)
30
35
33.5
1100
700
270
30 (50)
31
39
33.5
1100
700
270
30 (50)
32
43
33.5
1100
700
270
220-240, 1, 50
0.59
SUZ-A12VR
1.10
1.11
1900
47
34
800
285
550
20
12
0.8
6
10
0.68
SUZ-A18VR
1.67
1.78
1900
55
72
840
330
850
30
15
0.9
6
12
0.95
SUZ-A24VR
1.92
2.02
2196
55
72
840
330
850
30
15
1.4
6
16
220-240, 1, 50
5.0
8.0
9.0
* Factory charged to 7 m pipe length, for further information please view page 25
The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber
15
Series MSX Multi-Split
Cooling Only
Wall Mounted Systems
Advantages:
●
Cooling capacity between 2.8
kW and 7.3 kW per outdoor
unit
● Up to four wall mounted
indoor units with different
capacity can be connected
for cooling 2, 3 or 4 rooms
● Independent infrared
controller with 24-hours
on/off-timer
● Expandable system, units
can be added at any time
● Multi-Split configurations
provide greater economy and
comfort due to quiet operation noise, MSC-A07/09 YV
only 25 dB(A)
●
The energy-saving rotary
compressor enables quiet
economical performance
● Auto restart function
● Refrigerant R410A
MSC WALL MOUNTED INDOOR UNITS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
MSC-A07YV
Cooling
Low
High
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height*
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
POWER CONSUMPTION (W)
PIPE SIZE
Liquid
ø (mm)
Gas
MSC-A09YV
MSC-A12YV
Depending on combinations, view pages 17-19
276
474
25
36
9
815
244
278
0.17
35
6
10
306
474
25
36
9
815
244
278
220-240, 1, 50
0.17
35
6
10
324
582
26
40
10
815
244
278
0.19
40
6
12
COMBINATION WITH 2 WALL MOUNTED INDOOR UNITS:
OUTDOOR UNIT
CAPACITY (kW)
CONNECTABLE INDOOR
UNITS
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Number
Type
Width
Depth
Height
TOTAL PIPE LENGTH (m)
MAX. PIPE LENGTH per indoor unit (m)
MAX. HEIGHT DIFFERENCE
DIFFERENCE (m)
COMPRESSORS (pc)
CHARGE R410A (kg)*
Quantity
Apportionment
Charge for (m)
Apportionment
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY (V, Phase, Hz)
RUNNING CURRENT (A)
POWER
CONSUMPTION (kW)
MUX-A10WV
2.8
1-2
2 x 07
1914
49
35
780
255
540
30
15
MUX-A19WV
5.9
1-2
1 x 07 + 1 x 12
2460
52
66
840
330
640
30
15
MUX-A25WV
7.0
1-2
2 x 12
2460
52
68
840
330
640
30
15
10
10
10
1
0.90 (2 x 0.7)
–
10 (2 x 0.7)
–
2x6
2 x 10
2
0.95 (12)
0.95 (12)
7 (12)
7 (12)
2x6
2 x 12
3.59
2
1.0 (12)
0.8 (07)
7 (12)
7 (07)
2x6
1 x 10/ 1 x 12
220-240, 1, 50
9.32
0.8
2.08
2.64
11.87
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m
below the unit in anechoic chamber
* The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25
16
Series MSX Multi-Split Systems
Cooling Only 2 Wall Mounted Indoor Units
Twin Combination:
MSX-A10WV
●
●
2.8 kW cooling capacity
up to 2 connectable indoor units
2 x MSC-A07YV
MSC-A07YV
COOLING CAPACITY (kW)
OPERATION
MUX-A10WV
1 indoor unit
MSC-A07YV
INDOOR UNIT INDOOR UNIT
MSC-A07YV
MSC-A07YV
2.40
–
–
2.40
1.40
2 indoor unit
MSX-A19WV
1.40
●
5.9 kW cooling capacity
● up to two connectable indoor units
1 x MSC-A07YV
1 x MSC-A12YV
MSC-A12YV
COOLING CAPACITY (kW)
OPERATION
MUX-A19WV
1 indoor unit
MSC-A07YV
INDOOR UNIT INDOOR UNIT
MSC-A12YV
MSC-A07YV
3.50
–
–
2.40
3.50
2 indoor unit
MSX-A25WV
2.40
●
7.0 kW cooling capacity
● up to two connectable indoor units
2 x MSC-A12YV
MSC-A12YV
COOLING CAPACITY (kW)
OPERATION
MUX-A25WV
MSC-A12YV
1 indoor unit
2 indoor unit
INDOOR UNIT INDOOR UNIT
MSC-A12YV
MSC-A12YV
3.50
–
–
3.50
3.50
3.50
17
Series MSX Multi-Split Systems Cooling Only 3 or 4 Wall Mounted Indoor Units
MSC WALL MOUNTED INDOOR UNITS
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
MSC-A07YV
Cooling
Low
High
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
POWER CONSUMPTION (W)
PIPE SIZE
Liquid
ø (mm)
Gas
MSC-A09YV
MSC-A12YV
Depending on combinations, view pages 17-19
276
474
25
36
9
815
244
278
0.17
35
6
10
306
474
25
36
9
815
244
278
220-240, 1, 50
0.17
35
6
10
324
582
26
40
10
815
244
278
0.19
40
6
12
COMBINATION WITH 3 OR 4 WALL MOUNTED INDOOR UNITS:
OUTDOOR UNIT
CAPACITY (kW)
CONNECTABLE INDOOR
UNITS
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Number
Type
Width
Depth
Height
TOTAL PIPE LENGTH (m)
MAX. PIPE LENGTH per indoor unit (m)
MAX. HEIGHT
DIFFERENCE (m)
COMPRESSORS (pc)
CHARGE R410A (kg)*
Quantity
Apportionment
Charge for (m)
Apportionment
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY (V, Phase, Hz)
RUNNING CURRENT (A)
POWER CONSUMPTION
incl. indoor units (kW)
MUX-A20WV
6.0
1-3
3 x 09
2460
52
65
840
330
640
45
15
MUX-A22WV
6.5
1-3
2 x 07 + 1 x 12
2460
52
67
840
330
640
45
15
MUX-A26WV
7.3
1-4
2 x 09 + 2 x 12
2760
52
77
840
330
850
60
15
10
10
10
2
0.80 (09)
1.0 (2 x 09)
7 (09)
10 (2 x 09)
3x6
3 x 10
2
1.05 (2 x 09)
1.05 (2 x 12)
10 (2 x 09)
10 (2 x 12)
4x6
2 x 10 / 2 x 12
8.92
2
0.85 (12)
0.85 (2 x 07)
7 (12)
10 (2 x 07)
3x6
2 x 10 / 1 x 12
220-240, 1, 50
8.92
1.99
1.98
2.36
10.47
The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m
below the unit in anechoic chamber
* The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25
18
TRIPLE COMBINATION:
MSX-A20WV
MSC-A09YV
●
6.0 kW cooling capacity
● up to 3 connectable indoor units
3 x MSC-A09YV
COOLING CAPACITY (kW)
MUX-A20WV
MSC-A09YV
MSC-A09YV
OPERATION
INDOOR UNIT
MSC-A09YV
INDOOR UNIT INDOOR UNIT
MSC-A09YV
MSC-A09YV
1 indoor unit
2.60
–
–
–
2.90
–
–
–
2.90
2 indoor unit
2.60
2.60
–
2.80
–
1.75
–
2.80
2.00
2.50
1.75
1.75
3 indoor unit
MSX-A22WV
●
●
MSC-A12YV
6.5 kW cooling capacity
up to 3 connectable indoor units
1 x MSC-A12YV
2 x MSC-A07YV
COOLING CAPACITY (kW)
MUX-A22WV
MSC-A07YV
OPERATION
INDOOR UNIT
MSC-A12YV
1 indoor unit
3.50
–
–
–
2.40
–
–
–
2.40
2 indoor unit
3.50
3.50
–
2.40
–
1.45
–
2.40
1.45
3 indoor unit
3.40
1.45
1.45
MSC-A07YV
MSX-A26WV
●
●
MSC-A12YV
INDOOR UNIT INDOOR UNIT
MSC-A07YV
MSC-A07YV
7.3 kW cooling capacity
up to 4 connectable indoor units
2 x MSC-A12YV
2 x MSC-A09YV
COOLING CAPACITY (kW)
OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT
MSC-A12YV MSC-A12YV MSC-A09YV MSC-A09YV
MUX-A26WV
MSC-A12YV
1 indoor unit
3.40
–
–
–
–
3.40
–
–
–
–
2.75
–
–
–
–
2.75
2 indoor unit
1.95
3.40
3.40
–
–
–
1.95
–
–
3.40
3.40
–
–
2.70
–
2.70
–
1.70
–
–
2.70
–
2.70
1.70
3 indoor unit
1.95
1.95
3.40
–
1.95
1.95
–
3.40
2.80
–
1.70
1.70
–
2.80
1.70
1.70
4 indoor unit
1.95
1.95
1.70
1.70
MSC-A09YV
MSC-A09YV
19
Series MXZ Inverter Multi-Split
Systems Cooling/Heating
Energy-saving inverter
technology provides highest
comfort year-round
● Very quiet operation
● Factory charged with R410A
● Can operate with up to four
indoor units connected
● Various indoor units available:
Wall mounted systems, floor
or ceiling mounted systems,
ceiling concealed system and
in-ceiling cassette system
●
●
Combination of indoor
units with different capacity
possible
● Special control retains
customised temperature
adjustment
● Auto restart function
● Winterkit in cooling mode up
to -15° C*, view page 5
* for MXZ-A26/32 WV
MXZ INVERTER MULTI-SPLIT SYSTEMS COOLING/HEATING
OUTDOOR UNIT
CAPACITY (kW)
POWER CONSUMPTION
incl. indoor units (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Heating
Cooling
Heating
Width
Depth
Height
MAX. PIPE LENGTH per indoor unit (m)
TOTAL PIPE LENGTH (m)
MAX. HEIGHT
DIFFERENCE (m)
CHARGE R410A* (kg)
Pipe size
Liquid
Ø (mm)
Gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
MXZ-A18WV
5.4 (1.55 - 6.0)
6.6 (1.58 - 7.2)
1.86 (0.37 - 2.13)
1.77 (0.29 - 1.85)
2460
50
52
909
330
640
20
30
MXZ-A26WV
7.2 (2.9 - 8.5)
9.0 (2.6 - 11.0)
2.09 (0.72 - 2.56)
2.15 (0.53 - 3.05)
2630
48
69
900
360
900
25
50
MXZ-A32WV
8.0 (3.7 - 9.2)
9.4 (3.4 - 11.6)
2.19 (0.81 - 2.58)
1.93 (0.59 - 3.23)
2630
48
70
900
360
900
25
70
10
1.75
2x6
2 x 10
10
3.5
3x6
1 x 12 / 2 x 10
220-240, 1, 50
9.18
9.44
10
3.5
4x6
2 x 12 / 2 x 10
8.98
8.55
* Factory charged for max. pipe lengths please view page 25
REMARK: The Multi-Split Systems run either cooling or heating mode.
At least two indoor units have to be connected.
Possible combinations on page 21, 22 and 23.
20
9.62
8.48
Series MXZ Inverter Multi-Split
Systems Cooling/Heating
MXZ-A18WV
• Wall mounted systems:
• Floor or ceiling mounted systems:
• Ceiling concealed systems:
• In-ceiling cassette systems:
Combination
Model
Mode
07
09
12
07+07
07+09
07+12
09+09
09+12
12 +12
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
Cooling / HEATING
A
2.30 / 3.30
2.50 / 3.60
3.40 / 4.00
2.30 / 3.05
2.30/ 2.97
2.02 / 2.62
2.50 / 3.25
2.20 / 2.78
Cooling / HEATING 2.65 / 3.30
MSC-A07/09/12YV
MCFH-A12WV
SEZ-A12AR
SLZ-A09/12AR, SLP-2AL (Grille)
Capacity (kW)
B
–/–
–/–
–/–
2.30 / 3.05
2.50 / 3.23
2.98 / 3.88
2.50 / 3.25
3.10 / 3.77
2.65 / 3.30
TOTAL
2.3 (0.90 - 2.95) / 3.30 (0.90 - 4.00)
2.5 (0.90 - 3.30) / 3.60 (0.90 - 4.50)
3.4 (0.90 - 4.00) / 4.00 (0.90 - 4.80)
4.6 (1.49 - 5.30) / 6.10 (1.53 - 6.70)
4.8 (1.49 - 5.40) / 6.20 (1.53 - 6.80)
5.0 (1.51 - 5.60) / 6.50 (1.55 - 7.00)
5.0 (1.51 - 5.55) / 6.50 (1.55 - 7.00)
5.3 (1.53 - 5.80) / 6.55 (1.56 - 7.10)
5.4 (1.55 - 6.00) / 6.60 (1.58 - 7.20)
COMBINATION
EXAMPLES
MXZ-A18WV Please refer to the
following table for
permitted combinations
MSC-A12YV
SEZ-A12AR
MXZ-A18WV
SLZ-A09/12AR
SLP-2AL (Grille)
MCFH-A12WV
MXZ-A18WV
21
MXZ-A26WV
Kombination
Model
7
9
12
18
24
07+07
07+09
07+12
07+18
07+24
09+09
09+12
09+18
09+24
12+12
12+18
12+24
18+18
18+24
07+07+07
07+07+09
07+07+12
07+07+18
07+07+24
07+09+09
07+09+12
07+09+18
07+09+24
07+12+12
07+12+18
07+12+24
07+18+18
07+18+24
09+09+09
09+09+12
09+09+18
09+09+24
09+12+12
09+12+18
09+12+24
09+18+18
09+18+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24
22
• Wall mounted systems:
• Floor or ceiling mounted systems:
• Ceiling concealed systems:
• In-ceiling cassette systems:
Mode
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
MSC-A07/09/12YV, MSH-A18/24WV
MCFH-A12/18/24WV
SEZ-A12/18/24AR
SLZ-A09/12/18AR (grille SLP-2AL)
Capacity (kW)
A
2.3 / 3.3
2.5 / 3.6
3.4 / 4.0
5.0 / 7.2
6.0 / 7.9
2.3 / 3.3
2.1 / 3.02
2.1 / 2.69
2.01 / 2.49
1.62 / 2.03
2.5 / 3.6
2.52 / 3.26
2.4 / 3.0
1.96 / 2.45
3.4 / 4.0
2.88 / 3.6
2.4 / 3.0
3.6 / 4.5
3.08 / 3.86
2.3 / 2.9
2.16 / 2.67
1.93 / 2.42
1.58 / 1.96
1.32 / 1.65
2.01 / 2.52
1.8 / 2.25
1.48 / 1.85
1.26 / 1.57
1.62 / 2.03
1.36 / 1.7
1.17 / 1.46
1.17 / 1.46
1.02 / 1.28
2.36 / 3.0
2.16 / 2.7
1.8 / 2.25
1.45 / 1.92
1.97 / 2.45
1.66 / 2.07
1.44 / 1.8
1.44 / 1.8
1.27 / 1.58
2.4 / 3.0
2.05 / 2.57
1.8 / 2.25
1.8 / 2.25
1.6 / 2.0
B
C
2.3 / 3.3
2.7 / 3.88
3.6 / 4.61
5.18/ 6.41
5.57 / 6.97
2.5 / 3.6
3.37 / 4.34
4.8 / 6.0
5.23 / 6.55
3.4 / 4.0
4.32 / 5.4
4.8 / 6.0
3.6 / 4.5
4.11 / 5.14
2.3 / 2.9
2.16 / 2.67
1.93 / 2.42
1.58 / 1.96
1.32 / 1.65
2.59 / 3.24
2.31 / 2.89
1.9 / 2.38
1.62 / 2.02
2.79 / 3.48
2.33 / 2.91
2.0 / 2.51
3.01 / 3.76
2.64 / 3.0
2.36 / 3.0
2.16 / 2.7
1.8 / 2.25
1.45 / 1.92
2.61 / 3.27
2.21 / 2.76
1.92 / 2.4
2.88 / 3.6
2.54 / 3.17
2.4 / 3.0
2.05 / 2.57
1.8 / 2.25
2.7 / 3.37
2.4 / 3.0
2.3 / 2.9
2.77 / 3.44
3.32 / 4.15
4.05 / 5.06
4.55 / 5.68
2.59 / 3.24
3.09 / 3.85
3.81 / 4.76
4.32 / 5.4
2.79 / 3.48
3.5 / 4.37
4.01 / 5.02
3.01 / 3.76
3.52 / 4.4
2.36 / 3.0
2.89 / 3.6
3.6 / 4.5
4.11 / 5.14
2.61 / 3.27
3.32 / 4.15
3.84 / 4.8
2.88 / 3.6
3.38 / 4.23
2.4 / 3.0
3.08 / 3.85
3.6 / 4.5
2.7 / 3.37
3.2 / 4.0
Total
2.3 (1.4-3.0) / 3.3 (1.2-4.2)
2.5 (1.4-3.3) / 3.6 (1.2-4.5)
3.4 (1.5-4.3) / 4.0 (1.2-4.8)
5.0 (1.6-5.6) / 7.2 (1.4-8.2)
6.0 (1.6-6.6) / 7.9 (1.4-8.6)
4.6 (2.0-5.4) / 6.6 (1.8-7.2)
4.8 (2.0-5.8) / 6.9 (1.8-8.7)
5.7 (2.0-6.6) / 7.3 (1.8-9.2)
7.2 (2.0-7.7) / 8.9 (1.8-9.9)
7.2 (2.0-8.0) / 9.0 (1.8-9.9)
5.0 (2.0-6.2) / 7.2 (1.8-9.1)
5.9 (2.0-7.3) / 7.6 (1.8-9.5)
7.2 (2.0-8.5) / 9.0 (1.8-10.1)
7.2 (2.0-8.5) / 9.0 (1.8-10.1)
6.8 (2.0-8.5) / 8.0 (1.8-9.8)
7.2 (2.0-8.5) / 9.0 (1.8-10.5)
7.2 (2.0-8.5) / 9.0 (1.8-10.5)
7.2 (2.1-8.5) / 9.0 (1.9-11.0)
7.2 (2.1-8.5) / 9.0 (1.9-11.0)
6.9 (2.9-8.1) / 8.7 (2.6-10.6)
7.1 (2.9-8.5) / 8.8 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.6-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
7.2 (2.9-8.5) / 9.0 (2.7-11.0)
MXZ-A32WV
Combination
Model
Model
7
9
12
18
24
07+07
07+09
07+12
07+18
07+24
09+09
09+12
09+18
09+24
12+12
12+18
12+24
18+18
18+24
24+24
07+07+07
07+07+09
07+07+12
07+07+18
07+07+24
07+09+09
07+09+12
07+09+18
07+09+24
07+12+12
07+12+18
07+12+24
07+18+18
07+18+24
09+09+09
09+09+12
09+09+18
09+09+24
09+12+12
09+12+18
09+12+24
09+18+18
09+18+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24
07+07+07+07
07+07+07+09
07+07+07+12
07+07+07+18
07+07+07+24
07+07+09+09
07+07+09+12
07+07+09+18
07+07+09+24
07+07+12+12
07+07+12+18
07+07+12+24
07+07+18+18
07+09+09+09
07+09+09+12
07+09+09+18
07+09+09+24
07+09+12+12
07+09+12+18
07+09+12+24
07+12+12+12
07+12+12+18
09+09+09+09
09+09+09+12
09+09+09+18
09+09+09+24
09+09+12+12
09+09+12+18
09+12+12+12
12+12+12+12
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
• Wall mounted systems:
• Floor or ceiling mounted systems:
• Ceiling concealed systems:
• In-ceiling cassette systems:
MSC-A07/09/12YV, MSH-A18/24WV
MCFH-A12/18/24WV
SEZ-A12/18/24AR
SLZ-A09/12/18AR (grille SLP-2AL)
Capacity (kW)
A
2.3 / 3.3
2.5 / 3.6
3.4 / 4.0
5.0 / 7.2
6.0 / 7.9
2.3 / 3.3
2.1 / 3.02
2.1 / 2.69
2.04 / 2.49
1.75 / 2.12
2.5 / 3.6
2.52 / 3.26
2.5 / 3.0
2.11 / 2.56
3.4 / 4.0
3.1 / 3.76
2.61 / 3.13
3.95 / 4.7
3.42 / 4.03
4.0 / 4.7
2.3 /2.9
2.16 / 2.67
2.07 / 2.53
1.72 / 2.05
1.46 / 1.73
2.04 / 2.49
1.93 / 2.35
1.62 / 1.93
1.4 / 1.64
1.77 / 2.12
1.49 / 1.77
1.3 / 1.53
1.3 / 1.53
1.14 / 1.34
2.36 / 3.0
2.32 / 2.82
1.97 / 2.35
1.71 / 2.01
2.15 / 2.56
1.84 / 2.16
1.6 / 1.88
1.6 / 1.88
1.41 / 1.65
2.65 / 3.13
2.28 / 2.68
2.0 / 2.35
2.0 / 2.35
1.77 / 2.08
1.95 / 2.35
1.83 / 2.19
1.68 / 1.99
1.43 / 1.68
1.24 / 1.46
1.72 / 2.05
1.59 / 1.88
1.36 / 1.6
1.19 / 1.4
1.47 / 1.73
1.27 / 1.49
1.12 / 1.31
1.12 / 1.31
1.62 / 1.93
1.5 / 1.77
1.3 / 1.53
1.14 / 1.34
1.4 / 1.64
1.21 / 1.43
1.07 / 1.26
1.3 / 1.53
1.14 / 1.34
1.97 / 2.35
1.84 / 2.16
1.6 / 1.88
1.41 / 1.65
1.56 / 1.83
1.5 / 1.76
1.6 / 1.88
2.0 / 2.35
B
C
D
2.3 / 3.3
2.7 / 3.88
3.6 / 4.61
5.25 / 6.41
6.0 / 7.28
2.5 / 3.6
3.37 / 4.34
5.0 / 6.0
5.64 / 6.84
3.4 / 4.0
4.65 / 5.64
5.24 / 6.27
3.95 / 4.7
4.57 / 5.37
4.0 / 4.7
2.3 /2.9
2.16 / 2.67
2.07 / 2.53
1.72 / 2.05
1.46 / 1.73
2.62 / 3.2
2.49 / 3.02
2.09 / 2.48
1.8 / 2.11
3.04 / 3.63
2.56 / 3.04
2.23 / 2.62
3.34 / 3.93
2.93 / 3.45
2.36 / 3.0
2.32 / 2.82
1.97 / 2.35
1.71 / 2.01
2.85 / 3.41
2.46 / 2.89
2.13 / 2.5
3.2 / 3.76
2.82 / 3.31
2.65 / 3.13
2.28 / 2.68
2.0 / 2.35
3.0 / 3.52
2.66 / 3.13
1.95 / 2.35
1.83 / 2.19
1.68 / 1.99
1.43 / 1.68
1.24 / 1.46
1.72 / 2.05
1.59 / 1.88
1.36 / 1.6
1.19 / 1.4
1.47 / 1.73
1.27 / 1.49
1.12 / 1.31
1.12 / 1.31
2.09 / 2.48
1.93 / 2.28
1.67 / 1.96
1.46 / 1.72
1.8 / 2.11
1.56 / 1.83
1.38 / 1.62
2.23 / 2.62
1.95 / 2.3
1.97 / 2.35
1.84 / 2.16
1.6 / 1.88
1.41 / 1.65
1.75 / 2.06
1.5 / 1.76
2.13 / 2.5
2.0 / 2.35
2.3 /2.9
2.77 / 3.44
3.55 / 4.33
4.41 / 5.28
5.03 / 5.93
2.62 / 3.2
3.33 / 4.02
4.18 / 4.97
4.8 / 5.64
3.04 / 3.63
3.84 / 4.57
4.46 / 5.24
3.34 / 3.93
3.91 / 4.6
2.36 / 3.0
3.11 / 3.76
3.95 / 4.7
4.57 / 5.37
2.85 / 3.41
3.69 / 4.33
4.26 / 5.01
3.2 / 3.76
3.76 / 4.42
2.65 / 3.13
3.42 / 4.02
4.0 / 4.7
3.0 / 3.52
3.55 / 4.17
1.95 / 2.35
1.83 / 2.19
1.68 / 1.99
1.43 / 1.68
1.24 / 1.46
2.2 / 2.64
2.04 / 2.41
1.75 / 2.06
1.53 / 1.8
2.52 / 2.96
2.18 / 2.56
1.92 / 2.25
2.88 / 3.38
2.09 / 2.48
1.93 / 2.28
1.67 / 1.96
1.46 / 1.72
2.4 / 2.82
2.08 / 2.45
1.84 / 2.16
2.23 / 2.62
1.95 / 2.3
1.97 / 2.35
1.84 / 2.16
1.6 / 1.88
1.41 / 1.65
2.34 / 2.75
2.0 / 2.35
2.13 / 2.5
2.0 / 2.35
1.95 / 2.35
2.36 / 2.82
2.91 / 3.41
3.69 / 4.33
4.26 / 5.01
2.2 / 2.64
2.72 / 3.22
3.51 / 4.12
4.08 / 4.8
2.52 / 2.96
3.27 / 3.84
3.84 / 4.51
2.88 / 3.38
2.09 / 2.48
2.59 / 3.04
3.34 / 3.93
3.91 / 4.60
2.4 / 2.82
3.13 / 3.67
3.69 / 4.33
2.23 / 2.62
2.93 / 3.45
1.97 / 2.35
2.46 / 2.89
3.2 / 3.76
3.76 / 4.42
2.34 / 2.75
3.0 / 3.52
2.13 / 2.5
2.0 / 2.35
Total
2.3 (1.4-3.0) / 3.3 (1.2-4.2)
2.5 (1.4-3.3) / 3.6 (1.2-4.5)
3.4 (1.5-4.3) / 4.0 (1.2-4.8)
5.0 (1.6-5.6) / 7.2 (1.4-8.4)
6.0 (1.6-6.6) / 7.9 (1.4-8.6)
4.6 (2.0-5.4) / 6.6 (1.8-7.2)
4.8 (2.0-5.8) / 6.9 (1.8-8.7)
5.7 (2.0-6.6) / 7.3 (1.8-9.2)
7.3 (2.0-7.7) / 8.9 (1.8-9.9)
7.75 (2.0-8.0) / 9.4 (1.8-9.9)
5.0 (2.0-6.2) / 7.2 (1.8-9.1)
5.9 (2.0-7.3) / 7.6 (1.8-9.5)
7.5 (2.0-8.5) / 9.0 (1.8-10.1)
7.75 (2.0-8.5) / 9.4 (1.8-10.1)
6.8 (2.0-8.8) / 8.0 (1.8-9.8)
7.75 (2.0-8.8) / 9.4 (1.8-10.5)
7.85 (2.0-8.8) / 9.4 (1.8-10.5)
7.9 (2.1-8.8) / 9.4 (1.9-11.2)
8.0 (2.1-8.8) / 9.4 (1.9-11.2)
8.0 (2.1-8.8) / 9.4 (1.9-11.2)
6.9 (2.9-8.1) / 8.7 (2.6-10.6)
7.1 (2.9-8.6) / 8.8 (2.6-11.1)
7.7 (2.9-9.0) / 9.4 (2.6-11.6)
7.85 (2.9-9.0) / 9.4 (2.6-11.6)
7.95 (2.9-9.0) / 9.4 (2.6-11.6)
7.3 (2.9-8.9) / 8.9 (2.6-11.6)
7.75 (2.9-9.0) / 9.4 (2.6-11.6)
7.9 (2.9-9.0) / 9.4 (2.6-11.6)
8.0 (2.9-9.0) / 9.4 (2.6-11.6)
7.85 (2.9-9.0) / 9.4 (2.6-11.6)
7.9 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
7.1 (2.9-9.0) / 9.0 (2.6-11.6)
7.75 (2.9-9.0) / 9.4 (2.6-11.6)
7.9 (2.9-9.0) / 9.4 (2.6-11.6)
8.0 (2.9-9.0) / 9.4 (2.6-11.6)
7.85 (2.9-9.0) / 9.4 (2.6-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
7.95 (2.9-9.0) / 9.4 (2.6-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
8.0 (2.9-9.0) / 9.4 (2.7-11.6)
7.8 (3.7-9.2) / 9.4 (3.4-11.6)
7.8 (3.7-9.2) / 9.4 (3.4-11.6)
7.95 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
7.85 (3.7-9.2) / 9.4 (3.5-11.6)
7.95 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
7.9 (3.7-9.2) / 9.4 (3.4-11.6)
7.95 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
7.9 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.5-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
8.0 (3.7-9.2) / 9.4 (3.4-11.6)
23
Series Accessories
AIR CLEANING FILTER
MODEL REFERENCE QUANTITY APPLICABLE MODELS
MAC-1300FT
10
MSC-A07/09/12YV
MSZ-A09/12YV
MAC-1700FT
10
MS(H)-A18/24/30WV
MAC-1200FT
10
MCF/MCFH
DEODORISING FILTER
MODEL REFERENCE QUANTITY APPLICABLE MODELS
MAC-1700DF
10
MCF/MCFH
QUICK CLEAN KIT
MODEL REFERENCE QUANTITY APPLICABLE MODELS
MAC-093SS-E1
1
MSZ-A09/12YV
Series Refrigerant Charge
OUTDOOR UNITS with R410A
• Mostly factory charged to 7 m pipe length (one-way).
• Please view the required refrigerant charge for other pipe lengths in
the following table.
MU-A07/09/12/18/24/30YV/WV
OUTDOOR UNITS
(MODELS)
MU-A07YV
MU-A09YV
MU-A12YV
MU-A18WV
MU-A24WV
MU-A30WV
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
0.660
0.760
0.860
0.660
0.760
0.860
0.810
0.910
1.010
1.460
1.560
1.660
1.960
2.060
2.160
2.465
2.740
3.015
7m
0.600
0.600
0.750
1.400
1.900
2.300
25 m
–
–
1.110
1.760
2.260
3.290
30 m
–
–
–
–
–
3.465
MUH-A07/09/12/18/24/30YV/WV
OUTDOOR UNITS
(MODELS)
MUH-A07YV
MUH-A09YV
MUH-A12YV
MUH-A18WV
MUH-A24WV
MUH-A30WV
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
0.680
0.780
0.880
1.060
1.160
1.260
1.060
1.160
1.260
1.810
1.910
2.010
2.210
2.310
2.410
2.465
2.740
3.015
7m
0.620
1.000
1.000
1.750
2.150
2.300
25 m
–
–
1.360
2.110
2.510
3.290
30 m
–
–
–
–
–
3.565
MUCFH-A18/24WV
OUTDOOR UNITS
(MODELS)
MUCFH-A18WV
MUCFH-A24WV
24
7m
1.850
2.200
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
1.910
2.010
2.110
2.260
2.360
2.460
25 m
2.210
2.560
Series Refrigerant Charge
MUZ-A09/12/18/24/26 YV
OUTDOOR UNITS
(MODELS)
MUZ-A 09 YV
MUZ-A 12 YV
MUZ-A 18 YV
MUZ-A 24 YV
MUZ-A 26 YV
7m
0.860
0.960
1.800
1.800
2.000
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
0.950
1.100
1.250
1.050
1.200
1.350
1.860
1.960
2.060
1.860
1.960
2.060
2.165
2.265
2.365
25 m
–
–
2.160
2.160
2.465
30 m
–
–
2.260
2.260
2.565
7m
0.860
0.960
1.800
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
0.950
1.100
1.250
1.050
1.200
1.350
1.860
1.960
2.060
25 m
–
–
2.160
30 m
–
–
2.260
SUZ-A09/12/18YV
OUTDOOR UNITS
(MODELS)
SUZ-A 09 YV
SUZ-A 12 YV
SUZ-A 18 YV
MUX-A10/19/25/20/22/26WV
OUTDOOR UNITS
(MODELS)
Compressor
Indoor Units
Models
7m
CHARGE (ONE-WAY) in kg
10 m
15 m
20 m
25 m
30 m
MUX-A10WV
MUX-A19WV
1
1
1
2 X MSC-A07YV
1 X MSC-A12YV
1 X MSC-A09YV
–
1.000*
0.800*
0.900*
1.060
0.860
0.950
1.160
0.960
1.000
–
–
1.050
–
–
1.100
–
–
MUX-A25WV
1
1
1 X MSC-A12YV
1 X MSC-A12YV
0.950*
0.950*
1.010
1.010
1.110
1.110
–
–
–
–
–
–
MUX-A20WV
1
1
1 X MSC-A09YV
2 X MSC-A09YV
0.800*
–
0.860
1.000*
0.960
1.050
–
1.100
–
1.150
–
1.200
MUX-A22WV
1
1
1 X MSC-A12YV
2 X MSC-A07YV
0.850*
–
0.910*
0.850*
1.010
0.900
–
0.950
–
1.000
–
1.050
MUX-A26WV
1
1
2 X MSC-A09YV
2 X MSC-A12YV
–
–
1.050*
1.050*
1.100
1.100
1.150
1.150
1.200
1.200
1.250
1.250
* Factory charged
MXZ-A18/26/32WV
OUTDOOR UNITS
(MODELS)
MXZ-A18WV
MXZ-A26WV
MXZ-A32WV
20 m
1.750
–
–
25 m
1.850
–
–
CHARGE (ONE-WAY) in kg
30 m
40 m
50 m
1.950
–
–
3.500
3.600
3.700
3.500
3.600
3.700
60 m
–
–
3.900
70 m
–
–
4.100
25
25
Mr. Slim Series
Split- and Multi-Split Systems,
R407C
Cooling 3.15 kW - 26.0 kW
The Mr. Slim Series offers a huge choice of components
and configurations for a wide range of applications.
The packaged air conditioners are adapted for middlesized rooms, shops, restaurants and offices - for cooling
only or with heat pump-function. With ceiling cassettes,
ceiling suspended units, wall mounted units and ceiling
ducted units, there is a Mr. Slim model which provides
the optimum fit for your next job.
26
Advantages of Mr. Slim
● Wide range of indoor units
● Simultaneous operation of 2, 3
or 4 indoor units
● Standard long-life filters
● Auto change over between
cooling and heating mode
● Heat pump with warm start
system
● Indoor units without electrical
heater connectable to heat
pump outdoor units
● A-Control makes servicing
easier. Automatic switching
between heating and cooling
is available on heat pump units.
Error codes are shown at
remote controls display of
indoor units.
● Wired or infrared remote
controller optional
● Maintenance Tool for control
and service
●
All models can be interfaced to
Building Management Systems
by Lon Works Interface
● Lossnay heat exchange
ventilators connectable
● Factory charged with R407C
● Winter kit as standard, cooling
up to -15°
Rating conditions Mr. Slim
Series* R407C:
● Cooling
Indoor: 19°C - 35°C DB
15°C - 22.5°C WB
Outdoor: -15°C - 46°C DB
●
Heating
Indoor: 17°C - 28°C DB
Outdoor: -11°C - 24°C DB
-12°C - 18°C WB
* For PUH-P8/10MYA other rating
conditions, please view page 61
COOLING ONLY
PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
PLA COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
PCA CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .36
PKA WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
PSA FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
HEAT PUMP UNITS - COOLING AND HEATING
PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
PLA/PLH COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . .46
PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
PCA/PCH CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .52
PKA/PKH WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
PSA/PSH FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
PEAD/PEHD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
PEH CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
27
27
Mr. Slim Series
PMH Cooling Only
1-Way-In-Ceiling Cassette Systems
●
Simple installation and service, ● Factory charged with R407C
because of compact dimen● Rotary and scroll compressors
sions – installation height only ●
Twin, triple and quadruple
230 mm
configuration possible
● Wired remote control
● Standard drain pump for 600
● Precisely directed airflow to
mm height differences
prevent dirt built-up and stai● External airflow prepared
ning of ceiling tiles
● 4 fan-stages for comfortable
● Standard long-life filter
and optimum airflow
● Simple installation and easy
Accessories:
access drain and refrigerant
piping connections
Optional parts on page 70 and
the following
28
28
PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS
COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT incl. Grille
DIMENSIONS (mm)
Indoor unit
DIMENSIONS (mm)
Grille
Cooling
Low
Middle 1
Middle 2
High
Low
High
(kg)
Width
Depth
Height*
Width
Depth
Height**
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
Cooling
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C*** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
PMH-P1.6 BA
4.4
420
480
540
600
34
40
14/17
854
395
230
1000
470
30
220-240, 1, 50
PMH-P2 BA
5.4
480
540
600
660
36
42
14/17
854
395
230
1000
470
30
220-240, 1, 50
0.29
PU-P1.6 YGAA
0.29
PU-P2 YGAA
1.6
2700
2.3
3300
47
55
900
350
650
40
40
2.5
10
16
380-415, 3, 50
48
71
900
350
855
40
40
2.6
10
16
380-415, 3, 50
2.5
3.7
*** Required installation height
*** Visible height of grille
*** Factory charged to 20 m pipe length, optional charging please view page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz
29
29
Mr. Slim Series
PLA Cooling Only
4-Way-In-Ceiling Cassette Systems
●
Wired remote control with
24h-timer
● Compact dimensions
● Simple installation with easy
access drain and refrigerant
piping connections
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 3.8 m
● Precisely directed airflow
to prevent dirt built-up and
staining of ceiling tiles
● Rotary and scroll compressors
● Factory charged with R407C
● Long-life air filter
● Drain pump for 500 mm height
difference
30
●
Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Space panel enables installation
into ceiling void of just 258 mm
depth
● Infrared remote control
● High efficiency filter and
external airflow
For detailed descriptions
please view on page 70 and
the following
Optional
PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT incl. Grille
DIMENSIONS (mm)
Indoor unit
DIMENSIONS (mm)
(Grille)
Cooling
Low
Middle 1
Middle 2
High
Low
High
(kg)
Width
Depth
Height*
Width
Depth
Height**
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
Cooling
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C*** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
PLA-P1.6 KA
4.4
780
840
900
960
32
37
19 / 22.7
660
660
298
760
760
30
PLA-P2 KA
5.3
780
840
900
960
32
37
19 / 22.7
660
660
298
760
760
30
PLA-P2.5 KA
6.3
840
900
960
1020
35
39.5
20 / 23.7
660
660
298
760
760
30
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.64
PU-P1.6 YGAA
0.65
PU-P2 YGAA
0.61
PU-P2.5 YGAA
1.8
2.4
2.6
2700
3300
3000
47
55
900
350
650
40
40
2.5
10
16
48
71
900
350
855
40
40
2.6
10
16
48
82
900
350
855
50
50
3.1
10
16
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
2.5
3.7
4.5
GRILLE-TYPE FOR WIRED REMOTE CONTROL
GRILLE-TYPE FOR INFRARED REMOTE CONTROL
PLP-2.5 KC
PLP-2.5 KLM
*** Required installation height
*** Visible height of grille
*** Factory charged to 20 m pipe length, for further information please view page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz
31
31
Mr. Slim Series
PLA Cooling Only
4-Way-In-Ceiling Cassette Systems
●
Wired remote control or
infrared remote control with
24h-timer
● Compact dimensions
● Extremely quiet operation
noise, PLA-P3AA just 28 dB(A)
● Weight reduced for PLA-P6AA
from 46 kg to only 37 kg
● Great convenience due to four
fan-stages
● Drain pump for 850 mm height
difference
● Simple installation with easy
access drain and refrigerant
piping connections
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 4.2 m
● Precisely directed airflow
to prevent dirt built-up and
staining of ceiling tiles
32
●
Rotary and scroll compressors
● Factory charged with R407C
● Long-life air filter
● Twin, triple, quadruple
configuration possible, on
page 72
Accessories:
Space panel enables
installation into ceiling void
of just 258 mm depth
● High efficiency filter and
external airflow
●
For detailed descriptions
please view on page 70 and
the following
PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT incl. Grille (kg)
DIMENSIONS (mm)
Indoor unit
DIMENSIONS (mm)
(Grille)
ELECTRICAL SUPPLY
(V, phase, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C***
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Low
Middle 1
Middle 2
High
Low
High
Width
Depth
Height*
Width
Depth
Height**
PLA-P3 AA
7.8
900
960
1080
1200
28
34
24/29
840
840
258
950
950
30
PLA-P4 AA
9.7
1200
1380
1560
1680
33
41
30/35
840
840
298
950
950
30
PLA-P5 AA
12.8
1320
1500
1680
1800
35
43
30/35
840
840
298
950
950
30
PLA-P6 AA
14.3
1320
1500
1680
1800
37
45
32/37
840
840
298
950
950
30
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
Cooling
0.81
PU-P3 YGAA
1.25
PU-P4 YGAA
1.43
PU-P5 YGAA
1.6
PU-P6 YGAA
Cooling
3.4
3000
3.7
5100
5.0
5700
5.9
6000
49
82
900
350
855
50
50
3.3
10
16
51
96
900
350
1260
50
50
4.0
10
18
55
122
1050
350
1260
50
50
4.6
10
18
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.3
5.6
7.6
9.0
Width
Depth
Height
(kg)
Liquid
Gas
Cooling
GRILLE-TYPE FOR WIRED REMOTE CONTROL
GRILLE-TYPE FOR INFRARED REMOTE CONTROL
PLP-6 AAM
PLP-6 AALM
*** Required installation height
*** Visible height of grille
*** Factory charged to 30 m pipe length, for further information please view page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
33
Mr. Slim Series
PCA Cooling Only
Ceiling Suspended Systems
●
Wired remote control with
24h-timer
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 3.5 m
● Rotary and scroll compressors
● Factory charged with R407C
● Long-life air filter
● Great convenience due to four
fan-stages
● Swing louvres with `Auto
Angle´ airflow
34
34
●
Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● High efficiency filter
● Drain pump
● Infrared remote control
For detailed descriptions
please view on page 70 and
the following
Optional
PCA CEILING SUSPENDED SYSTEMS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Low
Middle 1
Middle 2
High
Low
High
Width
Depth
Height
PCA-P2 GA
5.4
600
660
720
780
37
42
27
1000
680
210
PCA-P2.5 GA
6.7
840
900
960
1080
37
43
34
1310
680
210
PCA-P3 GA
7.5
840
900
960
1080
37
43
34
1310
680
210
220-240, 1, 50
220-240, 1, 50 220-240, 1, 50
PCA-P4 GA
9.7
1200
1260
1380
1500
40
45
37
1310
680
270
PCA-P5 GA
12.4
1620
1800
1920
2040
41
46
43
1620
680
270
PCA-P6 GA
14.3
1620
1800
1920
2040
42
48
45
1620
680
270
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
Cooling
0.43
PU-P2 YGAA
0.55
PU-P2.5 YGAA
0.55
PU-P3 YGAA
0.7
PU-P4 YGAA
1.1
PU-P5 YGAA
1.1
PU-P6 YGAA
Cooling
2.4
2.65
3.4
3.64
4.94
5.94
3300
3000
3000
5100
5700
6000
48
71
900
350
855
40
40
2.6
10
16
48
82
900
350
855
50
50
3.1
10
16
49
82
900
350
855
50
50
3.3
10
16
51
96
900
350
1260
50
50
4.0
10
18
55
122
1050
350
1260
50
50
4.6
10
18
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.55
7.6
9.0
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C* (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
380-415, 3, 50
3.7
380-415, 3, 50 380-415, 3, 50
4.5
5.29
* Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
35
Mr. Slim Series
PCA Cooling Only
Ceiling Suspended Systems For Applications In
Kitchens
The established ceiling
suspended system consisting
of stainless steel for applications in kitchens
● The special construction
enables easy cleaning of the
casing and of all airflow parts
● Oil particles can be filtered 1.5
times more efficient compared
to conventional types due
to high performance filter
(optional)
● On the rear panel round
knockout opening (Ø 200 mm)
allows more comfort by
supplying fresh air
●
36
Rotary and scroll
compressors
● Factory charged with R407C
● Wired remote control with
24h-timer
● Twin configuration possible,
on page 72
●
Accessories:
Oil mist filter (12 pcs.)
PAC-SG 38 KF-E
●
For detailed descriptions
please view on page 70 and
the following
PCA CEILING SUSPENDED SYSTEMS
COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Low
High
Low
High
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Width
Depth
Height
(kg)
Liquid
Gas
Cooling
PCA-P3HA
7.5
1020
1140
34
38
41
1136
650
280
PCA-P5HA
13.0
1800
2280
44
50
56
1520
650
280
220-240, 1, 50
220-240, 1, 50
0.55
1.1
PU-P3YGAA
PU-P5YGAA
3.36
4.90
3000
49
82
900
350
855
50
50
3.3
10
16
5700
55
122
1050
350
1260
50
50
4.6
10
18
380-415, 3, 50
380-415, 3, 50
5.29
7.60
* Factory charged to 30 m pipe length, for further information please view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
37
Mr. Slim Series
PKA Cooling Only
Wall Mounted Systems
●
Infrared remote control with
24h-timer
● Slim compact units for wall
mounting
● Simple installation with easy
access drain and refrigerant
piping connections
● Rotary and scroll compressors
● Factory charged with R407C
● Easily removable long-life air
filter
● PKA-P1.6/2 GAL with four
fan-stages
38
●
Swing louvres with “Auto
Angle” airflow
● Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Drain pump
● Wired remote control
For detailed descriptions
please view on page 70 and
the following
Optional
PKA WALL MOUNTED SYSTEMS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Low
Middle 1
Middle 2
High
Low
High
Width
Depth
Height
Cooling
Cooling
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C* (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
PKA-P1.6 GAL
4.5
540
600
660
720
36
43
16
990
235
340
PKA-P2 GAL
5.6
540
600
660
720
36
43
16
990
235
340
PKA-P2.5 FAL
6.5
900
–
–
1200
39
45
24
1400
235
340
PKA-P3 FAL
7.9
900
–
–
1200
39
45
24
1400
235
340
PKA-P4 FAL
9.5
1320
–
–
1680
41
46
28
1680
235
340
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.33
PU-P1.6 YGAA
0.33
PU-P2 YGAA
0.43
PU-P2.5 YGAA
0.43
PU-P3 YGAA
0.52
PU-P4 YGAA
1.7
2.4
2.7
3.4
3.6
2700
3300
3000
3000
5100
47
55
900
350
650
40
40
2.5
10
16
48
71
900
350
855
40
40
2.6
10
16
48
82
900
350
855
50
50
3.1
10
16
49
82
900
350
855
50
50
3.3
10
16
51
96
900
350
1260
50
50
4.0
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
2.5
3.7
4.5
5.3
5.6
* Factory charged to 20 m pipe length, PU-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
39
Mr. Slim Series
PSA Cooling Only
Floorstanding units
●
Function panel case integrated ● Standard long-life filter
● Twin and triple configuration
24h-timer
possible, on page 72
● Simple installation with easy
access drain and refrigerant
piping connections
Accessories:
● Rotary and scroll compressors
Optional parts on page 70 and
● Factory charged with R407C
the following
●
40
PSA FLOORSTANDING UNITS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Low
High
Low
High
Width
Depth
Height
Cooling
Cooling
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C* (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
PSA-P3 GA
7.7
900
1080
40
45
43
600
270
1900
PSA-P4 GA
9.7
1440
1860
44
49
51
600
350
1900
PSA-P5 GA
12.4
1560
1920
46
51
51
600
350
1900
PSA-P6 GA
14.0
1620
2100
47
52
53
600
350
1900
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.68
PU-P3 YGAA
1.1
PU-P4 YGAA
1.26
PU-P5 YGAA
1.62
PU-P6 YGAA
3.4
3.8
5.0
5.8
3000
5100
5700
6000
49
82
900
350
855
50
50
3.3
10
16
51
96
900
350
1260
50
50
4.0
10
18
55
122
1050
350
1260
50
50
4.6
10
18
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.3
5.6
7.6
9.0
* Factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m above.
41
Mr. Slim Series
PEAD Cooling Only
Above-Ceiling Concealed Ducted Systems
●
Wired remote control with
24h-timer
● Simple installation with easy
access drain and refrigerant
piping connections
● PEAD-P1.6/2/2.5 EA airflow
variable - draw in from the
back or underside
● Rotary and scroll compressors
● Factory charged with R407C
● Standard long-life filter
42
●
Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Drain pump
● Fan motor (external static
pressure 130 Pa)
For detailed descriptions
please view on page 70 and
the following
PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING ONLY
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
Cooling
Low
High
EXTERNAL STATIC PRESSURE (Pa)
NOISE dB(A)
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
Cooling
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C* (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
PEAD-P1.6EA
4.5
660
840
30(70)
34(36)
38(43)
33
935
700
295
PEAD-P2EA
5.6
810
1020
30(70)
36(38)
40(44)
33
935
700
295
PEAD-P2.5EA
6.7
1020
1260
30(70)
37(39)
41(46)
42
1175
700
295
PEAD-P3EA
7.7
1200
1500
70(130**)
37(40)
41(45)
44
1175
740
325
PEAD-P4EA
9.7
1620
2040
70(130**)
41(42)
46(48)
62
1415
740
325
PEAD-P5EA
12.3
2010
2520
70(130**)
44(46)
50(52)
65
1415
740
325
PEAD-P6EA
14.1
2190
2760
70(130**)
46(47)
51(53)
70
1715
740
325
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.55
PU-P1.6YGAA
0.61
PU-P2YGAA
0.7
PU-P2.5YGAA
1.7
PU-P3YGAA
2.6
PU-P4YGAA
2.7
PU-P5YGAA
2.8
PU-P6YGAA
1.8
2700
47
55
900
350
650
40
40
2.5
10
16
2.4
3300
48
71
900
350
855
40
40
2.6
10
16
2.7
3000
48
82
900
350
855
50
50
3.1
10
16
3.4
3000
49
82
900
350
855
50
50
3.3
10
16
3.9
5100
51
96
900
350
1260
50
50
4.0
10
18
4.9
5700
55
122
1050
350
1260
50
50
4.6
10
18
5.9
6000
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3. 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
2.5
3.7
4.5
5.3
5.6
7.6
9.0
** Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73
** Fan motor optional on page 70
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
43
Mr. Slim Series
PMH Cooling / Heating
1-Way-In-Ceiling Cassette Systems
●
Simple installation and service
because of compact dimensions - installation height only
230 mm
● Wired remote control with
24h-timer
● Quiet operation - only 29 dB(A)
at PMH-P1 BA
● Precisely directed airflow
to prevent dirt built-up and
staining of ceiling tiles
●
Standard long-life filter
Easy access drain and
refrigerant piping connections
● Factory charged with R407C
● Rotary and scroll compressors
● Drain pump for 600 mm height
difference
● External airflow prepared
● 4 fan-stages for comfortable
and optimum airflow
●
Accessories:
Optional parts on page 70 and
the following
44
PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT incl. Grille
DIMENSIONS (mm)
Indoor unit
DIMENSIONS (mm)
Grille
Cooling
Heating
Low
Middle 1
Middle 2
High
Low
High
(kg)
Width
Depth
Height*
Width
Depth
Height**
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
Heating
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C*** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
Heating
PMH-P1 BA
3.15
3.4
378
408
456
540
29
35
14/17
854
395
230
1000
470
30
220-240, 1, 50
PMH-P1.6 BA
4.4
5.0
420
480
540
600
34
40
14/17
854
395
230
1000
470
30
220-240, 1, 50
PMH-P2 BA
5.4
6.25
480
540
600
660
36
42
14/17
854
395
230
1000
470
30
220-240, 1, 50
0.19
0.19
PUH-P1 VGAA
1.15
1.06
2700
0.29
0.29
PUH-P1.6 YGAA
1.6
1.7
2700
0.29
0.29
PUH-P2 YGAA
2.3
2.4
3300
46
50
900
350
650
30
30
1.7
6
12
220-240, 1, 50
47
55
900
350
650
40
40
2.5
10
16
380-415, 3, 50
48
71
900
350
855
40
40
2.6
10
16
380-415, 3, 50
4.9
4.5
2.5
2.6
3.7
3.8
GRILLE-TYPE FOR WIRED REMOTE CONTROL
PMP-40 BM
*** Required installation height
*** Visible installation height
*** Factory charged to 20 m pipe length, for further information please view page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz
45
Mr. Slim Series
PLA Cooling / Heating
PLH Cooling / Heating
4-Way-In-Ceiling Cassette Systems
●
Wired remote control with
24h-timer
● PLH units with additional
electrical heating for a
warm start and to increase
capacity of heat pump
● 4 fan-stages for best comfort
● Precisely directed airflow to
prevent dirt built-up and
staining of ceiling tiles
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 3.8 m
● Standard long-life filter
● Simple installation with easy
access drain and refrigerant
piping connections
● Rotary and scroll
compressors
● Factory charged with R407C
46
●
Drain pump for 500 mm height
difference
● Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
Space panel enables
installation into ceiling void
of just 258 mm depth
● Infrared remote control
● High efficiency filter and
external airflow
●
For detailed descriptions
please view on page 70 and
the following
Optional
PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING
INDOOR UNIT
INDOOR UNIT WITH ELECTRICAL HEATING
CAPACITY (kW)
Cooling
Heating*
AIRFLOW (m3/h)
Low
Middle 1
Middle 2
High
NOISE dB(A)
Low
High
WEIGHT PLA incl. Grille (kg)
WEIGHT PLH incl. Grille (kg)
DIMENSIONS (mm)
Width
Indoor unit
Depth
Height**
DIMENSIONS (mm)
Width
Grille
Depth
Height***
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating*
OUTDOOR UNIT
POWER CONSUMPTION (kW)
Cooling
Heating*
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C**** (kg)
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Width
Depth
Height
Liquid
Gas
Cooling
Heating
GRILLE-TYPE FOR WIRED REMOTE CONTROL
GRILLE-TYPE FOR INFRARED REMOTE CONTROL
PLA-P1.6 KA
PLH-P1.6 KAH
4.4
5.0 (6.4)
780
840
900
960
32
37
19 / 22.7
20 / 23.7
660
660
298
760
760
30
PLA-P2 KA
PLH-P2 KAH
5.3
6.0 (7.4)
780
840
900
960
32
37
19 / 22.7
20 / 23.7
660
660
298
760
760
30
PLA-P2.5 KA
PLH-P2.5 KAH
6.3
7.4 (9.5)
840
900
960
1020
35
39.5
20 / 23.7
21 / 24.7
660
660
298
760
760
30
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.64
0.45 (5.83)
PUH-P1.6 YGAA
1.8
1.9 (3.3)
2700
0.65
0.45 (5.83)
PUH-P2 YGAA
2.4
2.4 (3.8)
3300
0.61
0.45 (8.75)
PUH-P2.5 YGAA
2.6
2.6 (4.7)
3000
47
55
900
350
650
40
40
2.5
10
16
48
71
900
350
855
40
40
2.6
10
16
48
82
900
350
855
50
50
3.1
10
16
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
2.5
2.6
3.7
3.8
4.5
4.3
PLP-2.5 KC
PLP-2.5 KLM
**** Values given in brackets incl. additional electrical heating
**** Required installation height
**** Visible height of grille
**** Factory charged to 30 m pipe length, optional charging on page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz
47
Mr. Slim Series
PLA Cooling / Heating
PLH Cooling / Heating
4-Way-In-Ceiling Cassette Systems
●
Wired remote control or
infrared remote control with
24h-timer
● PLH units with additional
electrical heating for a warm
start and to increase capacity
of heat pump
● Compact dimensions
● Extremely quiet operation
noise, PLA-P3AA just 28 dB(A)
● Weight reduced for PLA-P6AA
from 46 kg to only 37 kg
● 4 fan-stages for best comfort
● Drain pump for 850 mm height
difference
● Simple installation with easy
access drain and refrigerant
piping connections
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 4.2 m
48
●
Precisely directed airflow to
prevent dirt built-up and
staining of ceiling tiles
● Rotary and scroll compressors
● Factory charged with R407C
● Long-life air filter
● Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Space panel enables
installation into ceiling void
of just 258 mm depth
● High efficiency filter and
external airflow
For detailed descriptions
please view on page 70 and
the following
PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING
INDOOR UNIT
INDOOR UNIT WITH ELECTRICAL HEATING
CAPACITY (kW)
Cooling
Heating*
AIRFLOW (m3/h)
Low
Middle 1
Middle 2
High
NOISE dB(A)
Low
High
WEIGHT PLA incl. Grille (kg)
WEIGHT PLA incl. Grille (kg)
DIMENSIONS (mm)
Width
Indoor unit
Depth
Height**
DIMENSIONS (mm)
Width
Grille
Depth
Height***
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating*
OUTDOOR UNIT
POWER CONSUMPTION (kW)
Cooling
Heating*
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C****
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Width
Depth
Height
(kg)
Liquid
Gas
Cooling
Heating
GRILLE-TYPE FOR WIRED REMOTE CONTROL
GRILLE-TYPE FOR INFRARED REMOTE CONTROL
PLA-P3 AA
PLH-P3 AAH
7.8
9.3 (11.4)
900
960
1080
1200
28
34
24/29
26/31
840
840
258
950
950
30
PLA-P4 AA
PLH-P4 AAH
9.7
10.6 (12.7)
1200
1380
1560
1680
33
41
30/35
32/37
840
840
298
950
950
30
PLA-P5 AA
PLH-P5 AAH
12.8
14.9 (17.9)
1320
1500
1680
1800
35
43
30/35
32/37
840
840
298
950
950
30
PLA-P6 AA
PLH-P6 AAH
14.3
17.1 (20.1)
1320
1500
1680
1800
37
45
32/37
34/39
840
840
298
950
950
30
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.81
0.81 (8.75)
PUH-P3 YGAA
3.4
3.5 (5.6)
1.25
1.25 (10.83)
PUH-P4 YGAA
3.7
3.9 (6.0)
1.43
1.43 (12.5)
PUH-P5 YGAA
5.0
5.3 (8.3)
3000
5100
5700
1.64
1.64 (12.5)
PUH-P6 YGAA
5.9
6.4 (9.4)
6000
49
82
900
350
855
50
50
3.3
10
16
51
96
900
350
1260
50
50
4.0
10
18
55
122
1050
350
1260
50
50
4.6
10
18
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.3
5.6
5.6
5.9
7.6
8.2
9.0
9.6
PLP-6 AAM
PLP-6 AALM
**** Values given in brackets incl. additional electrical heating
**** Required installation height
**** Visible height of grille
**** Factory charged to 30 m pipe length, optional charging on page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
49
Mr. Slim Series
PCA Cooling / Heating
PCH Cooling / Heating
Ceiling Suspended Systems
●
Wired remote control with
24h-timer
● PCH units with additional
electrical heating for a warm
start and to increase capacity
of heat pump
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 3.5 m
● Rotary and scroll compressors
● Factory charged with R407C
● Long-life air filter
● 4 fan-stages for optimum
comfort
50
●
Swing louvres with
`Auto Angle´ airflow
● Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● High efficiency filter
● Drain pump
● Infrared remote control
For detailed descriptions
please view on page 70 and
the following
Optional
PCA/PCH CEILING SUSPENDED SYSTEMS COOLING / HEATING
INDOOR UNIT
INDOOR UNIT WITH ELECTRICAL HEATING
CAPACITY (kW)
Cooling
Heating*
3
AIRFLOW (m /h)
Low
Middle 1
Middle 2
High
NOISE dB(A)
Low
High
WEIGHT PCA (kg)
WEIGHT PCH (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating*
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating*
3
AIRFLOW (m /h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
PCA-P2 GA
PCA-P2.5 GA
PCA-P3 GA
PCH-P2 GAH PCH-P2.5 GAH PCH-P3 GAH
5.4
6.7
7.5
6.3 (7.7)
7.3 (9.4)
9.2 (11.3)
600
840
840
660
900
900
720
960
960
780
1080
1080
37
37
37
42
43
43
27
34
34
28.5
36
36
1000
1310
1310
680
680
680
210
210
210
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.43
0.55
0.55
0.43 (5.83)
0.55 (8.75)
0.55 (8.75)
PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA
2.4
2.65
3.4
2.4 (3.8)
2.7 (4.8)
3.5 (5.6)
3300
3000
3000
48
48
49
71
82
82
900
900
900
350
350
350
855
855
855
40
50
50
40
50
50
2.6
3.1
3.3
10
10
10
16
16
16
PCA-P4 GA
PCH-P4 GAH
9.7
10.6 (13.4)
1200
1260
1380
1500
40
45
37
39.5
1310
680
270
220-240, 1, 50
0.7
0.7 (11.25)
PUH-P4 YGAA
3.6
3.8 (6.55)
5100
51
96
900
350
1260
50
50
4.0
10
18
PCA-P5 GA
PCH-P5 GAH
12.4
14.9 (17.9)
1620
1800
1920
2040
41
46
43
46
1620
680
270
220-240, 1, 50
1.1
1.1 (12.5)
PUH-P5 YGAA
4.9
5.1 (8.1)
5700
55
122
1050
350
1260
50
50
4.6
10
18
PCA-P6 GA
PCH-P6 GAH
14.3
17.1 (20.1)
1620
1800
1920
2040
42
48
45
48
1620
680
270
220-240, 1, 50
1.1
1.1 (12.5)
PUH-P6 YGAA
5.9
6.3 (9.3)
6000
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
3.7
3.8
4.5
4.3
5.3
5.6
5.5
5.8
7.6
8.1
9.0
9.6
** Values given in brackets incl. additional electrical heating
** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
51
Mr. Slim Series
PCA Cooling / Heating
Ceiling Suspended Systems For Applications
In Kitchens
The established ceiling
suspended system consisting
of stainless steel for applications in kitchens
● The special construction
enables easy cleaning of the
casing and of all airflow parts
● Oil particles can be filtered 1.5
times more efficient compared
to conventional types due
to high performance filter
(optional)
● On the rear panel round
knockout opening (Ø 200 mm)
allows more comfort by
supplying fresh air
●
52
Rotary and scroll
compressors
● Factory charged with R407C
● Wired remote control with
24h-timer
● Twin configuration possible,
on page 72
●
Accessories:
● Oil mist filter (12 pcs.)
PAC-SG 38 KF-E
For detailed descriptions
please view on page 70 and
the following
PCA CEILING SUSPENDED SYSTEMS COOLING / HEATING
INDOOR UNIT
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Cooling
Heating
Low
High
Low
High
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
OUTDOOR UNIT
POWER
CONSUMPTION (kW)
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C*
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
Width
Depth
Height
(kg)
Liquid
Gas
Cooling
Heating
PCA-P3 HA
7.5
9.2
1020
1140
34
38
41
1136
650
280
PCA-P5 HA
13.0
16.0
1800
2280
44
50
56
1520
650
280
220-240, 1, 50
220-240, 1, 50
0.55
1.1
PUH-P3 YGAA
PUH-P5 YGAA
3.36
3.41
3000
49
82
900
350
855
50
50
3.3
10
16
4.90
4.98
5700
55
122
1050
350
1260
50
50
4.6
10
18
380-415, 3, 50
380-415, 3, 50
5.30
5.60
7.60
8.10
* Factory charged to 30 m pipe length, optional charging on page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
53
Mr. Slim Series
PKA Cooling / Heating
PKH Cooling / Heating
Wall Mounted Systems
●
Infrared remote control with
24h-timer
● PKH units with additional
electrical heating for a warm
start and to increase capacity
of heat pump
● Slim compact units for wall
mounting
● Simple installation with easy
access drain and refrigerant
piping connections
● Rotary and scroll compressors
● Factory charged with R407C
● Easily removable long-life
air filter
54
●
PKA/H-P1.6/2 GAL/H with
4 fan-stages
● Swing louvres with
`Auto Angle´ airflow
● Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Drain pump
● Wired remote control
For detailed descriptions
please view on page 70 and
the following
Optional
PKA/PKH WALL MOUNTED SYSTEMS COOLING / HEATING
INDOOR UNIT
INDOOR UNIT WITH ELECTRICAL HEATING
CAPACITY (kW)
Cooling
Heating*
AIRFLOW (m3/h)
Low
Middle 1
Middle 2
High
NOISE dB(A)
Low
High
WEIGHT PKA (kg)
WEIGHT PKH (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating*
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating*
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
PKA-P1.6 GAL
PKH-P1.6 GALH
4.5
5.0 (5.8)
540
600
660
720
36
43
16
17
990
235
340
PKA-P2 GAL
PKH-P2 GALH
5.4
6.3 (7.1)
540
600
660
720
36
43
16
17
990
235
340
PKA-P2.5 FAL
PKH-P2.5 FALH
6.5
7.4 (9.5)
900
–
–
1200
39
45
24
26
1400
235
340
PKA-P3 FAL
PKH-P3 FALH
7.9
9.5 (11.6)
900
–
–
1200
39
45
24
26
1400
235
340
PKA-P4 FAL
PKH-P4 FALH
9.5
10.9 (13.3)
1320
–
–
1680
41
46
28
30
1680
235
340
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
0.33
0.33 (3.3)
PUH-P1.6 YGAA
1.7
1.9 (2.7)
2700
47
55
900
350
650
40
40
2.5
10
16
0.33
0.33 (3.3)
PUH-P2 YGAA
2.4
2.4 (3.2)
3300
48
71
900
350
855
40
40
2.6
10
16
0.43
0.43 (8.75)
PUH-P2.5 YGAA
2.7
2.6 (4.7)
3000
48
82
900
350
855
50
50
3.1
10
16
0.43
0.43 (8.75)
PUH-P3 YGAA
3.4
3.6 (5.7)
3000
49
82
900
350
855
50
50
3.3
10
16
0.52
0.52 (10.0)
PUH-P4 YGAA
3.6
3.8 (6.2)
5100
51
96
900
350
1260
50
50
4.0
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
2.5
2.6
3.7
3.8
4.3
4.5
5.3
5.6
5.6
5.9
** Values given in brackets incl. additional electrical heating
** Factory charged to 20 m pipe length, PUH-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
55
Mr. Slim Series
PSA Cooling / Heating
PSH Cooling / Heating
Floorstanding units
Function panel case integrated ● Rotary and scroll compressors
and 24h-timer
● Factory charged with R407C
● PSH units with additional
● Standard long-life filter
electrical heating for a warm
● Twin and triple configuration
start and to increase capacity
possible, on page 72
of heat pump
● Compact design and high
capacity
● Simple installation with easy
Accessories:
access drain and refrigerant
Optional parts on page 70
piping connections
and the following
●
56
PSA/PSH FLOORSTANDING UNITS COOLING / HEATING
INDOOR UNIT
INDOOR UNIT WITH ELECTRICAL HEATING
CAPACITY (kW)
Cooling
Heating*
AIRFLOW (m3/h)
Low
High
NOISE dB(A)
Low
High
WEIGHT PSA (kg)
WEIGHT PSH (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating*
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating*
3
AIRFLOW (m /h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
PSA-P3 GA
PSH-P3 GAH
7.7
9.3 (11.4)
900
1080
40
45
43
45
600
270
1900
220-240, 1, 50
PSA-P4 GA
PSH-P4 GAH
9.7
10.9 (13.6)
1440
1860
44
49
51
53
600
350
1900
220-240, 1, 50
PSA-P5 GA
PSH-P5 GAH
12.4
14.6 (17.6)
1560
1980
46
51
51
53
600
350
1900
220-240, 1, 50
PSA-P6 GA
PSH-P6 GAH
14.0
17.1 (20.1)
1620
2100
47
52
53
55
600
350
1900
220-240, 1, 50
0.68
0.68 (8.75)
PUH-P3 YGAA
3.4
3.5 (5.6)
3000
49
82
900
350
855
50
50
3.3
10
16
1.1
1.1 (11.25)
PUH-P4 YGAA
3.8
3.9 (6.6)
5100
51
96
900
350
1260
50
50
4.0
10
18
1.26
1.26 (12.5)
PUH-P5 YGAA
5.0
5.4 (8.4)
5700
55
122
1050
350
1260
50
50
4.6
10
18
1.62
1.62 (12.5)
PUH-P6 YGAA
5.8
6.1 (9.1)
6000
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.3
5.6
5.6
5.9
7.6
8.1
9.0
9.6
** Values given in brackets incl. additional electrical heating
** Factory charged to 30 m pipe length, optional charging on page 73
The noise levels are measured at a position 1 m in front of and 1 m above.
57
Mr. Slim Series
PEAD Cooling / Heating
PEHD Cooling / Heating
Above-Ceiling Concealed Ducted Systems
●
Wired remote control with
24h-timer
● PEHD units with additional
electrical heating for a warm
start and to increase capacity
of heat pump
● Simple installation with easy
access drain and refrigerant
piping connections
● PEAD/PEHD-P1.6/2/2.5 EA/H
airflow variable - draw in from
the back or underside
● Rotary and scroll compressors
● Factory charged with R407C
58
●
●
Standard long-life filter
Twin, triple, quadruple
configuration possible,
on page 72
Accessories:
● Drain pump
● Fan motor (external static
pressure 130 Pa)
For detailed descriptions
please view on page 70 and
the following
PEAD/PEHD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING
INDOOR UNIT
PEAD-P1.6EA PEAD-P2EA
PEAD-P2.5EA PEAD-P3EA
INDOOR UNIT W. ELECTRICAL HEATING PEHD-P1.6EAH PEHD-P2EAH PEHD-P2.5EAH PEHD-P3EAH
CAPACITY (kW)
Cooling
4.5
5.6
6.7
7.7
Heating*
4.9 (5.9)
6.2 (7.2)
7.2 (8.7)
9.1 (11.2)
3
AIRFLOW (m /h)
Low
660
810
1020
1200
High
840
1020
1260
1500
EXTERNAL STATIC PRESSURE (Pa)
30(70)
30(70)
30(70)
70(130**)
NOISE dB(A)
Low
34(36)
36(38)
37(39)
37(40)
High
38(43)
40(44)
41(46)
41(45)
WEIGHT PEAD (kg)
33
33
42
44
WEIGHT PEHD (kg)
35
35
44
46
DIMENSIONS (mm)
Width
935
935
1175
1175
Depth
700
700
700
740
Height
295
295
295
325
ELECTRICAL SUPPLY
220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
0.55
0.63
0.7
1.7
Heating*
0.55 (4.71)
0.63 (4.8)
0.7 (7.0)
1.7 (10.4)
OUTDOOR UNIT
PUH-P1.6YGAA PUH-P2YGAA PUH-P2.5YGAA PUH-P3YGAA
POWER
Cooling
1.8
2.4
2.7
3.4
CONSUMPTION (kW)
Heating*
1.8 (2.8)
2.2 (3.2)
2.5 (4.0)
3.2 (5.3)
AIRFLOW (m3/h)
2700
3300
3000
3000
NOISE dB(A)
47
48
48
49
WEIGHT (kg)
55
71
82
82
DIMENSIONS (mm)
Width
900
900
900
900
Depth
350
350
350
350
Height
650
855
855
855
MAX. PIPE LENGTH (m)
40
40
50
50
MAX. HEIGHT DIFFERENCE (m)
40
40
50
50
CHARGE R407C*** (kg)
2.5
2.6
3.1
3.3
PIPE SIZE
Liquid
10
10
10
10
ø (mm)
Gas
16
16
16
16
ELECTRICAL SUPPLY
380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
2.5
3.7
4.3
5.3
Heating
2.6
3.8
4.5
5.6
PEAD-P4EA
PEHD-P4EAH
9.7
10.4 (12.9)
1620
2040
70(130**)
41(42)
46(48)
62
65
1415
740
325
PEAD-P5EA
PEHD-P5EAH
12.3
13.9 (16.9)
2100
2520
70(130**)
44(46)
50(52)
65
68
1415
740
325
PEAD-P6EA
PEHD-P6EAH
14.1
16.7 (19.7)
2190
2760
70(130**)
46(47)
51(53)
70
73
1715
740
325
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
2.6
2.6 (12.6)
PUH-P4YGAA
3.9
4.0 (6.5)
5100
51
96
900
350
1260
50
50
4.0
10
18
2.7
2.7 (15.2)
PUH-P5YGAA
4.9
4.8 (7.8)
5700
55
122
1050
350
1260
50
50
4.6
10
18
2.8
2.8 (15.2)
PUH-P6YGAA
5.9
6.0 (9.0)
6000
57
122
1050
350
1260
50
50
4.9
10
18
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
5.6
5.9
7.6
8.2
9.0
9.6
*** Values given in brackets incl. additional electrical heating
*** Fan motor optional on page 70
*** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
59
Mr. Slim Series
PEH Cooling / Heating
Concealed Ducted Systems
Wired remote control with
24h-timer
● Pressure to 150 Pa
● PUH-P8/10 MYA for
simultaneous operation of
Mr. Slim indoor units
● Factory charged with R407C
●
60
●
Twin, triple, quadruple
configuration possible, on
page 72
Accessories:
Optional parts on page 70 and
the following
PEH CONCEALED DUCTED SYSTEMS COOLING/HEATING
INDOOR UNIT
CAPACITY (kW)
Cooling
Heating
AIRFLOW (m3/h)
EXTERNAL STATIC PRESSURE (Pa)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
Heating
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
3
AIRFLOW (m /h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R407C* (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A) Cooling
Heating
PEH-P8 MYA
20.9
23.7
3600
50/150
53
74
1580
604
455
PEH-P10 MYA
26.0
30.5
4800
50/150
57
80
1580
604
455
380-415, 3, 50
380-415, 3, 50
1.1
1.1
PUH-P8 MYA
7.92
7.82
11100
56
215
990
840
1715
50
40
6.0
12
28
1.6
1.6
PUH-P10 MYA
9.96
9.56
11100
57
220
990
840
1715
50
40
6.5
12
28
380-415, 3, 50
380-415, 3, 50
13
12.8
16
15.4
* Factory charged, please view page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Rating conditions:
COOLING Indoor:
Outdoor:
HEATING Indoor:
Outdoor:
15°C - 24°C WB
-15°C - 46°C DB
15°C - 27°C WB
-12°C - 18°C DB
61
Mr. Slim R410A-Series
Power Inverter
Split and Multi-Split Systems
The established Mr. Slim Series with inverter
technology - efficient, economical and very quiet.
62
Advantages of
Mr. Slim R410A-Series
Power Inverter
● New inverter-technology and
refrigerant R410A enable high
energy-efficiency
● The wide range of performance allows an optimum
of convenience - for a quick
cooling and heating
● All outdoor units with LOW
NOISE - mode, only 44 dB(A)
at PUHZ-RP3VHA
● The indoor units “RP” can
be connected with Mr. Slim
R407C outdoor units
● Multi Split simultaneous
operation
● Standard long-life filters
● Auto change over between
cooling and heating mode
● A-Control makes servicing
easier. Automatic switching
between heating and cooling
is available on heat pump
units. Error codes are shown
at remote controls display of
indoor units
● Lossnay heat exchange
ventilators connectable
● Factory charged with
refrigerant R410A
● Wired or infrared remote
controller optional
●
Remote monitoring
● Maintenance Tool for control
and service
● All models can be interfaced
to Building Management
Systems by Lon Works
Interface
● Ceiling cassette models with
condensate pump
● Winter kit as standard,
cooling up to -15°C. If the unit
is placed in wind direction use
the optional part, view page
70 and the following
NEW!
Rating conditions
Mr. Slim Series:
● COOLING
Indoor: 19°C - 35°C DB
15°C - 22.5°C WB
Outdoor: -15°C - 46°C DB
● HEATING
Indoor: 17°C - 28°C DB
Outdoor: -11°C - 24°C DB
-12°C - 18°C WB
POWER INVERTERHEAT PUMP UNITS
PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
PKA WALL-MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
63
63
Mr. Slim Power Inverter
PLA Cooling / Heating
4-Way-In-Ceiling Cassette Systems
●
Wired or infrared remote
control with 24h-timer
provided
● Space-saving, quadratic
design
● Installation height only 258
mm (PLA-RP3 AA)
● Quiet operation noise just 28 dB(A) (PLA-RP3 AA)
● Drain pump for 850 mm height
difference
● Prepared duct connections:
round 150 mm, rectangular
350 x 100 mm
● 4 fan-stages for best comfort
● Precisely directed airflow
to prevent dirt built-up and
staining of ceiling tiles
● Adjustable air outlets for
optimum airflow for ceiling
heights up to 4.2 m
● Standard long-life filter cleaning necessary every
2,500 operating hours
NEW!
64
●
Simple installation with easy
access drain and refrigerant
piping connections
● Factory charged with R410A
● Rotary and scroll compressors
● Multi Split simultaneous
operation, view page 72
Accessories:
● Space panel for installation of
PLA-RP4/5/6AA into ceiling
void of just 258 mm depth
● High efficiency filter and
external airflow
For detailed descriptions
please view on page 70 and
the following
POWER INVERTER PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING
INDOOR UNIT
CAPACITY COOLING (Min. - Nominal - Max.) kW
CAPACITY HEATING (Min. - Nominal - Max.) kW
COP Cooling/Heating
Low
AIRFLOW (m3/h)
Middle 1
Middle 2
High
NOISE dB(A)
Low
High
WEIGHT incl. Grille (kg)
DIMENSIONS (mm)
Width
Indoor unit
Depth
Height**
DIMENSIONS (mm)
Width
Grille
Depth
Height***
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A****
PIPE SIZE
ø (mm)
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
PLA-RP3 AA
3.3 - 7.1 - 8.1
3.5 - 8.0 - 10.2
3.60/3.42
900
960
1080
1200
28
34
24/29
840
840
258
950
950
30
220-240, 1, 50
0.79
0.79
PUHZ-RP3VHA
1.97
2.34
PLA-RP4 AA
5.0 - 10.0 - 11.4
5.6 -11.2 - 14.0
3.30/3.30
1200
1380
1560
1680
33
41
30/35
840
840
298
950
950
30
220-240, 1, 50
1.25
1.25
PUHZ-RP4VHA
3.03
3.39
PLA-RP5 AA
6.0 - 12.5 - 14.0
6.0 - 14.0 - 16.0
3.21/3.28
1320
1500
1680
1800
37
45
30/35
840
840
298
950
950
30
220-240, 1, 50
1.43
1.43
PUHZ-RP5VHA
3.89
4.27
PLA-RP6 AA
6.2 - 14.0 - 15.3
6.2 - 16.0 - 18.0
2.81/3.26
1320
1500
1680
1800
37
45
32/37
840
840
298
950
950
30
220-240, 1, 50
1.6
1.6
PUHZ-RP6VHA
4.99
4.91
3300
6000
6000
6000
44*/47
75
950
360
943
50
30
3.5
10
16
46*/49
121
900
360
1350
75
30
5.5
10
16
47*/50
121
900
360
1350
75
30
5.5
10
16
48*/50
121
900
360
1350
75
30
5.5
10
16
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
8.0
9.7
25
12.3
13.9
32
15.8
17.5
32
20.3
20.7
40
Width
Depth
Height
(kg)
Liquid
Gas
Cooling
Heating
CIRCUIT BREAKER (A)
GRILLE-TYPE FOR WIRED REMOTE CONTROL
GRILLE-TYPE FOR INFRARED REMOTE CONTROL
PLP-6AAM
PLP-6AALM
**** LOW NOISE mode
**** Required installation height
**** Visible height of grille
**** Factory charged to 30 m pipe length, optional charging on page 73
The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.
Indoor units "RP" can be connected with Mr. Slim R407C outdoor units.
65
Mr. Slim Power Inverter
PKA Cooling / Heating
Wall Mounted Systems
●
Infrared remote control with
24h-timer
● Slim compact units for wall
mounting
● Flexible louvre for evenly
spread of air
● Simple installation with easy
access drain and refrigerant
piping connections
● Easily removable long-life air
filter
● Factory charged with R407C
NEW!
66
●
●
Rotary and scroll compressors
Multi Split simultaneous
operation possible, page 72
Accessories:
● Drain pump
● Wired remote control
For detailed descriptions
please view on page 70 and
the following
Optional
POWER INVERTER PKA WALL MOUNTED SYSTEMS COOLING / HEATING
INDOOR UNIT
CAPACITY COOLING (Min. - Nominal - Max.) kW
CAPACITY HEATING (Min. - Nominal - Max.) kW
COP Cooling/Heating
Low
AIRFLOW (m3/h)
High
NOISE dB(A)
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
AIRFLOW (m3/h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A**
(kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
CIRCUIT BREAKER (A)
PKA-RP3FAL
3.3 - 7.1 - 8.1
3.5 - 8.0 - 10.2
3.59 / 3.33
900
1200
39
45
24
1400
235
340
220-240, 1, 50
0.43
0.43
PUHZ-RP3VHA
1.98
2.40
3300
44*/47
75
950
360
943
50
30
3.5
10
16
PKA-RP4FAL
5.0 - 10.0 - 11.4
5.6 - 11.2 - 14.0
3.41 / 3.45
1320
1680
41
46
28
1680
235
340
220-240, 1, 50
0.52
0.52
PUHZ-RP4VHA
2.93
3.25
6000
46*/49
121
950
360
1350
75
30
5.5
10
16
220-240, 1, 50
220-240, 1, 50
8.0
9.7
25
12.3
13.9
32
** LOW NOISE mode
** Factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
Indoor units “RP” can be connected with Mr. Slim R407C outdoor units.
67
Mr. Slim Power Inverter
PEAD Cooling / Heating
Above-Ceiling Concealed Ducted Systems
●
Wired remote control with
24h-timer
● Standard long-life filter
● Installation height only 325
mm
● Simple installation with easy
access drain and refrigerant
piping connections
● Factory charged with R410A
● Rotary and scroll compressors
NEW!
68
●
Multi Split simultaneous
operation possible, page 72
Accessories:
● Drain pump
● Fan motor (external static
pressure 130 Pa)
For detailed descriptions
please view on page 70 and
the following
POWER INVERTER PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING
INDOOR UNIT
CAPACITY COOLING (Min. - Nominal - Max.) kW
CAPACITY HEATING (Min. - Nominal - Max.) kW
COP Cooling/Heating
Low
AIRFLOW (m3/h)
High
EXTERNAL STATIC PRESSURE (Pa)
NOISE dB(A)
Low
High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY (V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
OUTDOOR UNIT
POWER
Cooling
CONSUMPTION (kW)
Heating
3
AIRFLOW (m /h)
NOISE dB(A)
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH (m)
MAX. HEIGHT DIFFERENCE (m)
CHARGE R410A*** (kg)
PIPE SIZE
Liquid
ø (mm)
Gas
ELECTRICAL SUPPLY
(V, PHASE, Hz)
RUNNING CURRENT (A)
Cooling
Heating
CIRCUIT BREAKER (A)
PEAD-RP3EA
3.3 - 7.1 - 8.1
3.5 - 8.0 - 10.2
3.30/3.42
1200
1500
70(130**)
37(40)
41(45)
44
1175
740
325
220-240, 1, 50
1.6
1.6
PUHZ-RP3VHA
2.15
2.34
3300
44*/47
75
950
360
943
50
30
3.5
10
16
PEAD-RP4EA
5.0 - 10.0 - 11.2
5.6 - 11.2 - 14.0
3.25/3.22
1620
2040
70(130**)
41(42)
46(48)
62
1415
740
325
220-240, 1, 50
2.5
2.5
PUHZ-RP4VHA
3.08
3.48
6000
46*/49
121
950
360
1350
75
30
5.5
10
16
PEAD-RP5EA
6.0 - 12.5 - 14.0
6.0 - 14.0 - 16.0
3.39/3.41
2010
2520
70(130**)
44(46)
50(52)
65
1415
740
325
220-240, 1, 50
2.6
2.6
PUHZ-RP5VHA
3.69
4.11
6000
47*/50
121
950
360
1350
75
30
5.5
10
16
PEAD-RP6EA
6.2 - 14.0 - 15.3
6.2 - 16.0 - 18.0
2.85/3.36
2190
2760
70(130**)
46(47)
51(53)
70
1715
740
325
220-240, 1, 50
2.7
2.7
PUHZ-RP6VHA
4.91
4.76
6000
48*/50
121
950
360
1350
75
30
5.5
10
16
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
220-240, 1, 50
8.0
9.7
25
12.3
13.9
32
15.8
17.5
32
20.4
20.7
40
*** LOW NOISE mode
*** Fan motor optional 130 Pa
*** Factory charged to 30 m pipe length, please also view page 73
The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.
Indoor units "RP" can be connected with Mr. Slim R407C outdoor units.
69
Mr. Slim R407C/R410A-Series
Accessories
Accessories Indoor / Outdoor units
PART.NO.
DESCRIPTION
PLA/PLH
PAC-SEO6 WP-E
PAC-SEO1 AS-E
PAC-SE21 TM-E
PAC-SE13 KF-E
PAC-SE60 AS-E
PAC-SG03 TM-E
PAC-SG01 KF-E
4-WAY-IN-CEILING CASSETTE SYSTEMS
Wide panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH
Space panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH
Multi-function casement for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH
High efficiency filter for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH (PAC-SE21 TM-E needed)
Space panel for PLA-P 4/5/6 AA, PLH-P 4/5/6 AAH
Multi-function casement for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH
High efficiency filter for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH (PAC-SG03 TM-E needed)
PCA/PCH
PAC-SE85 DMA-E
PAC-SE86 DMA-E
PAC-SE80 KF-E
PAC-SE81 KF-E
PAC-SE82 KF-E
PAC-SL99A-E
CEILING SUSPENDED SYSTEMS
Drain pump for PCA-P 2/2.5/3 GA, PCH-P2/2.5/3 GAH
Drain pump for PCA-P 4/5/6 GA, PCH-P4/5/6 GAH
High efficiency filter for PCA-P2 GA, PCH-P2 GAH
High efficiency filter for PCA-P2.5/3/4 GA, PCH-P2.5/3/4 GAH
High efficiency filter for PCA-P5/6 GA, PCH-P5/6 GAH
Infrared remote control for PCA-P/PCH-P
PCA
PAC-SG38KF-E
CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS
Special high efficiency oil filter, 12 pieces
PKA/PKH
PAC-SE88 DM-E
PAR-20MAAT-E
WALL-MOUNTED SYSTEMS
Drain pump PKA-P/PKH-P
Wired remote control for PKH-P/PKA-P
PEAD/PEHD
PAC-KE03 DM-F
PAC-SK005 MT-F
PAC-SK004 MT-F
PAC-SK003 MT-F
CEILING CONCEALED SYSTEMS
Drain pump for PEAD-P/PEHD-P
Fan motor 130 Pa pressure for PEAD-P3 EA/PEHD-P3 EAH
Fan motor 130 Pa pressure for PEAD-P4 EA/PEHD-P4 EAH
Fan motor 130 Pa pressure for PEAD-P5/6 EA/PEHD-P5/6 EAH
PU/PUH
PAC-SF37 DS-E
PAC-SF08 SG-E
PAC-SF16 DP-E
PAC-SF17 DP-E
PAC-SF09 AG
OUTDOOR UNITS
Drain socket for Mr. Slim outdoor units P1.6 – P6
Air outlet guide for Mr. Slim outdoor units P1.6 – P6 (for P4/5/6 2x PAC-SF08 SG-E)
Drain pan PU(H)-P 1.6/4
Drain pan PU(H)-P 5/6
Airflow panel for cooling to -15° C for P1.6 – P6 (for P4/5/6 2x PAC-SF09 AG)
PUHZ
PAC-SG61DS-E
PAC-SG59SG-E
PAC-SG64DP-E
OUTDOOR UNITS
Drain socket for Mr. Slim Power Inverter outdoor units RP3-RP6
Air outlet guide for outdoor units RP3-RP6. RP4/5/6 require two PAC-SG59SG-E
Drain pan for PUHZ-RP3/4/5/6 VHA
70
Mr. Slim R407C/R410A-Series
Accessories
Control Accessories
PART.NO.
PAC-SE41 TS-E
PAC-SF48 MA-E
PAC-SF40 RM-E
PAC-SE55 RA-E
CMS-MNF-B
LMAP02-E
PAC-YT32PTA
PAC-SF50MA
PAC-SC50KUA
PAC-SK52ST
DESCRIPTION
External Temperature Sensor
A/M Net-Converter
Operation remote controller board
Remote on/off
Maintenance Tool, to use with PAC-SF48 MA-E and PAC-SC34 KUA
LonWorks®-Interface, to use with PAC-SF48 MA-E and PAC-SC50 KUA
LCD weekly set back program timer – operation only with wired remote control models
A/M Net-Converter for Mr. Slim Inverter PUHZ R410 A
Power Supply
Service-Display for outdoor units P1-P6 and RP3/4/5/6
Further information: Planning handbook Mr. Slim Series
71
Accessories for
Multi Split Systems*/Distributors:
●
Twin, triple, quadruple configuration of
Mr. Slim indoor units with single outdoor
units possible.
● Ideally suited to open plan areas in
small- to medium-sized offices or shops.
Mr. Slim R407C:
Combinations:
INDOOR UNITS
OUTDOOR UNITS
COMIBINATION
PU(H)-P3 YGAA
PU(H)-P4 YGAA
PU(H)-P5 YGAA
PU(H)-P6 YGAA
PUH-P8 MYA
PUH-P10 MYA
DISTRIBUTOR
PLA-P/PLH-P1.6/2/2.5/3/4/5 PSA-P/PSH-P3/4/5
PCA-P/PCH-P2/2.5/3/4/5 PEAD-P/PEHD-P1.6/2/2.5/3/4/5
PKA-P/PKH-P1.6/2/2.5/3/4 PMH-P1.6/2
Twin 50:50
1.6 + 1.6
2+2
2.5 +2.5
3+3
–
–
SDD-50 DA-E
Twin 50:50
4+4
5+5
SDD-50WSA-E
Triple 33:33:33
–
–
–
2+2+2
2.5 + 2.5 + 2.5
3+3+3
SDT-111 SA-E
Triple 25:25:50
–
–
–
1.6 + 1.6 + 3
2+2+4
2.5 + 2.5 + 5
SDT-112 SA-E
Triple 20:40:40
Quadruple 25:25:25:25
1.6 + 3 + 3
2+4+4
SDT-122 SA-E
2+2+2+2
2.5 + 2.5 + 2.5 + 2.5
SDT-1111 SA-E
Mr. Slim R410A:
Combinations:
INDOOR UNITS**
OUTDOOR UNITS
COMBINATION
PUHZ-RP3VHA
PUHZ-RP4VHA
PUHZ-RP5VHA
PUHZ-RP6VHA
DISTRIBUTOR
72
PLA-RP1.6/2/2.5/3
PKA-RP1.6/2/2.5/3
PEAD-RP1.6/2/2.5/3
Twin 50:50
1.6 + 1.6**
2 + 2**
2.5 +2.5**
3+3
SDD-50SR-E
Triple 33:33:33
–
–
–
2 + 2 + 2**
SDT-111R-E
** Attention: Only indoor units of same type can be installed.
In Multi-Split-Mode all indoor units have to be installed in the same room because of temperature sense
in the master unit.
** RP1.6/2/2.5 available from August 2004
Mr. Slim-Series
Technical Data Refrigerants
R407C/R410A
Charge R407C
CHARGING (ONE WAY) IN kg
20 m
30 m
40 m
1.7
1.8
–
2.5
2.6
3.0
2.6
3.1
3.7
3.1
3.3
3.9
3.3
–
3.9
4.0
–
4.7
4.6
–
5.3
4.9
–
5.6
7.5
8.0
8.5
8.0
8.5
9.0
OUTDOOR UNITS
10 m
1.7
2.5
2.6
3.1
–
–
–
–
7.0
7.5
●
50 m
PUH-P1 VGAA
–
Charge concerning single operation,
PU(H)-P1.6 YGAA
–
optional charges for simultaneous
PU(H)-P2 YGAA
–
operation as in the planning guide
PU(H)-P2.5 YGAA
4.5
PU(H)-P3 YGAA
4.5
described.
PU(H)-P4 YGAA
5.4
● Outdoor units P1-2.5: Factory charged
PU(H)-P5 YGAA
6.0
to 20 m pipe length
PU(H)-P6 YGAA
6.3
PUH-P8 MYA
9.0
● Outdoor units P3-P6: Factory charged
PUH-P10 MYA
9.5
to 30 m pipe length
● Outdoor units P8 and P10:
Factory charged 6 kg and 6.5 kg R407C. Please view in the table above pipe length and charging data
Correction Factor R407C
EFFICIENCY CLASS
CORRECTION FACTOR CAPACITY OF COOLING/HEATING
PIPE LENGTH (ONE WAY)/M
5
10
15
20
25
30
35
40
45
50
–/–
–/–
–/–
–/–
1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983
–/–
–/–
1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983
–/–
–/–
P1
1.00/1.00 0.992/0.997 0.983/0.996 0.978/0.994 0.966/0.991 0.959/0.989
P1.6
P2
P2.5
1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978
P3
1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978
P4
1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978
P5
1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978
P6
1.00/1.00 0.975/0.998 0.955/0.995 0.935/0.993 0.918/0.990 0.900/0.988 0.884/0.985 0.869/0.983 0.855/0.980 0.840/0.978
P8
1.00/1.00
0.980/1.00
0.980/1.00
0.979/1.00
0.975/1.00 0.965/0.995 0.960/0.995 0.940/0.995 0.935/0.995 0.930/0.995
P10
1.00/1.00
0.980/1.00
0.980/1.00
0.979/1.00
0.975/1.00 0.960/0.995 0.958/0.995 0.955/0.995 0.950/0.995 0.950/0.995
Charge R410A
● Outdoor units PUHZ-P3/4/5/6VHA
factory charged to 30 m pipe length
(one-way), optional charges as in the
table.
OUTDOOR UNITS
PUHZ-RP3VHA
PUHZ-RP4VHA
PUHZ-RP5VHA
PUHZ-RP6VHA
10 m
3.1
5.1
5.1
5.1
CHARGING (ONE WAY) IN kg
30 m
40 m
50 m
3.5
4.1
4.7
5.5
6.1
6.7
5.5
6.1
6.7
5.5
6.1
6.7
20 m
3.3
5.3
5.3
5.3
60 m
–
7.3
7.3
7.3
75 m
–
7.9
7.9
7.9
Correction Factor R410A
EFFICIENCY CLASS
PIPE LENGTH (ONE WAY)/M
CORRECTION FACTOR CAPACITY OF COOLING/HEATING
5
10
15
20
30
40
50
60
70
75
–/–
–/–
–/–
RP3
1.00/1.00 0.989/0.997 0.978/0.994 0.967/0.991 0.947/0.985 0.930/0.979 0.905/0.973
RP4
1.00/1.00 0.985/0.997 0.971/0.994 0.958/0.991 0.931/0.985 0.908/0.979 0.887/0.973 0.865/0.967 0.847/0.961 0.838/0.958
RP5
1.00/1.00 0.982/0.997 0.963/0.994 0.9470.991 0.914/0.985 0.885/0.979 0.858/0.973 0.834/0.967 0.812/0.961 0.802/0.958
RP6
1.00/1.00 0.976/0.997 0.953/0.994 0.932/0.991 0.893/0.985 0.858/0.979 0.828/0.973 0.800/0.967 0.776/0.961 0.764/0.958
73
City Multi-Series Y and R2
For large applications such as office blocks, hotels and
large retail stores, City Multi – variable refrigerant flow
(VRF) multi-split systems – offer significant advantages
over centralised plant systems.
A certain times of the year, many buildings can require
cooling in some areas and heating in others – even in
adjacent rooms.
The outstanding City Multi R2 and WR2 systems meet
this requirement by distributing surplus heat from
cooling operations to rooms where it is needed.
This can result in energy savings of up to 20% over
conventional systems. The water-cooled WR-system
is adaptable specially to high-rise buildings.
74
Advantages of the
City Multi-Series
●
City Multi Super Y-Series manages
up to 32 indoor units in a single
refrigerant circle
●
Simultaneous cooling and heating
with incomparable 2-pipe-system
●
By distributing surplus heat from
cooling operations to rooms where
it is needed, the result can be 15%
- 20% energy savings over conventional systems
●
Automatic switch of operating
mode (heating/cooling), the room
temperature stays constant
●
Many indoor units, capacity-steps
and installation possibilities to
select
●
Inverter-driven outdoor
compressor units with very
low start currents
●
Remote control of individual
indoor units, to centralised
systems, right up to full interface
with industry standard Building
Management Systems
CITY MULTI Y-Series
City Multi Y-Series utilise 2-pipe
technology for cooling and heating
mode. By manual switch the most
comfortable air conditions can be
choosen. The system is very
versatile, it is possible to install
up to 32 different indoor units to
a single refrigerant circle. The
capacity of all installed indoor
units can be 50% up to 130%.
CITY MULTI R2-Series
The City Multi range has been
re-engineered to use R407C
ozone-friendly refrigerant – without
performance loss. Modern
buildings with a reduced exchange
of air, technical equipment like
PCs, printer etc. which warm up
the air require efficient
air conditioning with simultaneous
cooling and heating. The
"Fuzzy-logic” makes individual air
conditioning with max. 24 indoor
units possible. Inverter-driven
outdoor compressor units with very
low start currents save energy.
Distributing surplus heat from
cooling operations to rooms where
it is needed is another way to save
energy.
Operating range
of City Multi
●
Cooling: indoor 15° – 24°C
(WB)/outdoor -5° – 43°C (DB)
(water temperature for
WR2: 10°C – 45°C)
● Heating (Y-Series):
indoor 15° – 27°C (DB)/
outdoor -15° – 15.5°C (WB)
● Heating (R2-Series):
indoor 15° – 27°C (DB)/
outdoor -15° – 15.5°C (WB)
(water temperature for
WR2: 10°C – 45°C)
Control options to suit
every kind of application
City Multi systems offer an extremely
wide choice of control solutions,
from remote control of individual
indoor units, to centralised systems
and computer-aided systems which
allow to control up to 2,000 units.
Right up to full interface with
industry standard Building
Management Systems.
Features of City Multi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
City Multi Y-series - Outdoors units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
City Multi R2 series - Outdoors units and BC-controllers . . . . . . . . . . . . . . . . . . . . . . 82
PMFY/PLFY - Ceiling cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
PCFY/PKFY - Suspended indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
PEFY - Concealed ducted indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
PFFY - Floor standing indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
City Multi - Control accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
City Multi - Accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
75
City Multi Systems:
Economic, efficient and high-quality
CITY MULTI Y-SERIES
Switching between Heating and Cooling
Flexible and Powerful Response from Compact Dimensions Flexibility is the motto with the City Multi Y-Series. A wide line-up of
indoor units in combination with a flexible piping system can conform to any layout. From 8 to 32 indoor units, depending on capacity, can be
connected to Y-Standard, BIG Y and SUPER Y outdoor units.
All indoor units connected to only one refrigerant circuit. This enables easy air
conditioning of areas requiring individual control. In common with the R2, the
City Multi Y-Series can be easily operated through a central controller.
Header
Branch
Indoor unit
Y-Series
Outdoor unit
Indoor unit
76
CITY MULTI R2-SERIES
Simultaneous Cooling and
Heating excellent air conditioning
under the aspect of economy.
The R2-System means that simultaneous cooling and heating is possible. With the BC Controller connecting from 4 to
24 indoor units to one outdoor unit using only two
pipes and energy-saving heat recovery operation,
economy and efficiency are guaranteed. Smooth
auto-switching (heating/cooling) based on set
temperature realises easier operation and more
comfortable environment in auto-mode. The
WR2-System uses the same technical bases like
the well-known R2-System. But the WR2-Series
is the world´s only simultaneous heating/cooling
two-pipe system with water-cooled outdoor units.
WR2-System is specially for high-rise buildings.
R2-Series
Outdoor unit
WR2-Series
Outdoor unit
Conference room
(cooling)
Water
piping
Connection
Office
(cooling)
BC Controller
Two-Pipe system
OA room
(cooling)
Conference
room (heating)
Office (heating)
World-wide the only
system for simultaneous
cooling and heating
with 2 pipes.
77
Mitsubishi Electric
FEATURES of CITY MULTI
Flexible and Adaptable
The variety provided by 19 outdoor models and 65 indoor models
(9 different types) increase design flexibility.
The Y-Series:
Cooling or heating mode, a maximum of 32 indoor units
connectable with one refrigerant circuit.
The R2-Series:
Simultaneous heating/cooling with up to 24 indoor units
and heat recovery by BC-controller.
R407C
WR2-Series:
World´s only simultaneous heating/cooling two-pipe system with water-cooled
outdoor units.
SERIES
Outdoor
unit
Cooling
capacity
(kW)
Heating
capacity
(kW)
No. of
Connect
indoor units
Total
capacity
indoor units
Capacity of
connectable
indoor models*
Y-SERIES
PUMY-P125 YMA
PUY-P200 YEM-A
PUY-P250 YEM-A
PUY-P315 YEM-A
PUHY-P200 YEM-A
PUHY-P250 YEM-A
PUHY-P315 YEM-A
14.0
22.4
28.0
35.5
22.4
28.0
35.5
16,0
–
–
–
25.0
31.5
40,0
1-8
1-13
1-16
1-16
1-13
1-16
1-16
50 - 130%
20 - 125
50 - 130 %
20 - 250
BIG YSERIES
PUHY-P400 YMF-C
PUHY-P500 YMF-C
45.0
56.0
50.0
63.0
1-20
1-20
50 - 130%
25 - 250
SUPER YSERIES
PUHY-P400 YMF-C + PUHN-P200 YMF-C
PUHY-P400 YMF-C + PUHN-P250 YMF-C
PUHY-P500 YMF-C + PUHN-P200 YMF-C
PUHY-P500 YMF-C + PUHN-P250 YMF-C
67.4
73.0
78.4
84.0
75.0
81.5
88.0
94.5
2-32
2-32
2-32
2-32
50 - 130%
20 - 250
R2-SERIES
PURY-P200 YEM-A
PURY-P250 YEM-A
22.4
28.0
25.0
31.5
1-15
1-16
50 - 150%
20 - 250
BIG R2SERIES
PURY-P400 YMF-C
PURY-P500 YMF-C
45.0
56.0
50.0
63.0
2-24
2-24
50 - 150%
20 - 250
WR2SERIES
PQRY-P200 YMF-C
PQRY-P250 YMF-C
22.4
28.0
25.0
31.5
1-15
1-16
50 - 150%
20 - 250
* Indoor units available: Type 20 (2.2 kW) up to type 250 (28.0 kW)
78
Indoor units
- Overview
Capacity
Type
All City Multi indoor units are compatible to Y-Series,
R2- and WR2-Series.
Capacity code
P 20 P 25 P 32 P 40 P 50 P 63 P 71 P 80 P 100 P 125 P 140 P 200 P 250
Cooling capacity (kW)
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
11.2
14.0
16.0
22.4
28.0
Heating capacity (kW)
2.5
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
18.0
25.0
31.5
Ceiling Cassette Type
(1-way airflow)
PMFY-VBM-A
● ● ● ●
Ceiling Cassette Type
(2-way airflow)
PLFY-VLMD-A/-B
● ● ● ● ● ●
● ● ●
B-model
A-model
Ceiling Cassette Type
(4-way airflow)
● ● ● ●
PLFY-VKM-A/VAM-A
● ● ●
Ceiling Concealed
(horizontal airflow)
PEFY-VML-A/VMH-A
● ● ● ● ● ● ● ● ● ● ● ● ●
H-model*
L-model*
Ceiling Concealed
(variable airflow)
PEFY-VMM-A
● ● ● ● ● ● ● ● ● ● ●
Ceiling Suspended
Type
●
PCFY-VGM-A
●
● ●
Wall Mounted Type
PKFY-VAM-A
● ●
Wall Mounted Type
PKFY-VGM-A
● ● ●
Floor Standing
Exposed Type
PFFY-VLEM-A
Floor Standing
Concealed Type
PFFY-VLRM-A
● ● ● ● ● ●
● ● ● ● ● ●
* L-model: low stat. pressure, H-model: high stat. pressure
79
Outdoor units - Technical data
City Multi Y-Series, Cooling or Heating
OUTDOOR UNIT PUMY-P125 YMA
MODEL REFERENCE
PUMY-P125 YMA
CAPACITY (kW)
14.0
16.0
5400
54
127
1020
350
1280
100
30
8.5
10
18
380-415V, 50Hz, 3
5.95
5.58
8
9.1
1-8 / 20-125
Cooling
Heating
AIRFLOW
(m3/h)
NOISE*
dB(A)
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Height*
MAX. PIPE LENGTH**
(m)
MAX. HEIGHT DIFFERENCE
(m)
CHARGE R407C***
(kg)
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
STARTING CURRENT
(A)
RUNNING CURRENT
(A)
INDOOR UNITS TO INSTALL
(pcs.)
City Multi
Y-Series:
PUMY-P125 YMA
City Multi
Standard Y:
PU(H)Y-P
200/250/315
YEM-A
STANDARD Y OUTDOOR UNIT
MODEL REFERENCE
CAPACITY (kW)
Cooling
Heating
AIRFLOW
(m3/h)
NOISE*
dB(A)
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Height*
MAX. PIPE LENGTH**
(m)
MAX. HEIGHT DIFFERENCE
(m)
CHARGE R407C
(kg)
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
STARTING CURRENT
(A)
RUNNING CURRENT
(A)
INDOOR UNITS TO INSTALL (Number/Type)
COOLING ONLY
COOLING/HEATING
PUYP200YEM-A
PUYP250YEM-A
PUYP315YEM-A
PUHYP200YEM-A
22.4
–
12000
56
225
990
840
1755
240
50
7
12
28
380-415V, 50Hz, 3
6.32
–
8
10.6
1-13/20-250
28.0
–
12000
57
225
990
840
1755
240
50
7
12
28
35.5
–
12000
60
240
990
840
1755
240
50
9
12
35
380-415V, 50Hz, 3
12.3
–
8
20.3
1-16/20-250
22.4
25.0
12000
56
225
990
840
1755
240
50
7
12
28
8.54
–
8
14.4
1-16/20-250
*** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.
*** one-way
*** Factory charged to 50 m pipe length (one-way)
80
6.32
6.80
8
11.4
1-13/20-250
PUHYP250YEM-A
28.0
31.5
12000
57
225
990
840
1755
240
50
7
12
28
380-415V, 50Hz, 3
8.54
8.95
8
15.1
1-16/20-250
PUHYP315YEM-A
35.5
40.0
12000
60
240
990
840
1755
240
50
9
12
35
12.3
12.49
8
20.6
1-16/20-250
City Multi BIG Y
and Super Y-Series
BIG Y OUTDOOR UNITS
MODEL REFERENCE
CAPACITY (kW)
AIRFLOW
NOISE*
WEIGHT
DIMENSIONS (mm)
MAX. PIPE LENGTH**
MAX. HEIGHT DIFFERENCE
CHARGE R407C
PIPE SIZE ø (mm)
Cooling
Heating
(m3/h)
dB(A)
(kg)
Width
Depth
Height
(m)
(m)
(kg)
liquid
gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
INDOOR UNITS TO INSTALL
(pcs.)
PUHY-P400YMF-C PUHY-P500YMF-C
45.0
56.0
50.0
63.0
22200
22200
60
60
440
475
1990
1990
840
840
1715
1715
220
220
50
50
16
22
16
16
35
35
380-415V, 50Hz, 3
16.3
20.5
15.2
19.0
1-20/25-250
City Multi Big Y:
PUHY-P400/500 YMF-C
PUHN UNITS
MODEL REFERENCE
CAPACITY (kW)
AIRFLOW
NOISE*
WEIGHT
DIMENSIONS (mm)
MAX. PIPE LENGTH**
MAX. HEIGHT DIFFERENCE
CHARGE R407C
PIPE SIZE ø (mm)
Cooling
Heating
(m3/h)
dB(A)
(kg)
Width
Depth
Height
(m)
(m)
(kg)
liquid
gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
PUHN-P200YMF-C
PUHN-P250YMF-C
22.4
28.0
25.0
31.5
11100
11100
61
62
240
255
990
990
840
840
1715
1715
220
220
50
50
6.5
8.5
12
12
28
28
380-415V, 50Hz, 3
Depending of Combination
City Multi
Super Y
SUPER Y:
COMBINATION OF BIG Y AND PUHN
MODEL REFERENCE
Super Y PUHY-P400YMF-C + PUHN-P200YMF-C
Super Y PUHY-P400YMF-C + PUHN-P250YMF-C
Super Y PUHY-P500YMF-C + PUHN-P200YMF-C
Super Y PUHY-P500YMF-C + PUHN-P250YMF-C
Cooling capacity (kW)
Heating capacity (kW)
67.4
73.0
78.4
84.0
75.0
81.5
88.0
94.5
Noise level
dB(A)
61.5
62.0
61.5
62.0
Indoor units to install
(pcs.)
2-32/20-250
2-32/20-250
2-32/20-250
2-32/20-250
When adding 20 or more indoor units to one system transmission booster
PAC-SF46EPA is needed. For connecting PUHN use SUPER Y Kit CMC-30A.
** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.
** one-way
81
Outdoor units - Technical data
City Multi R2-Series
Cooling + Heating
simultaneous with
heat recovery
City Multi R2:
PURY-P 200/250
YEM-A
R2-OUTDOOR UNITS
MODEL REFERENCE
CAPACITY (kW)
Cooling
Heating
AIRFLOW
(m3/h)
NOISE*
dB(A)
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Height
MAX. PIPE LENGTH**
(m)
MAX. HEIGHT DIFFERENCE
(m)
CHARGE R407C
(kg)
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
STARTING CURRENT
(A)
RUNNING CURRENT
(A)
INDOOR UNITS TO INSTALL
(pcs.)
PURYP200YEM-A
PURYP250YEM-A
22.4
25.0
12000
56
238
990
840
1755
240
50
10.5
18
28
380-415V, 50Hz, 3
6.32
6.80
8
11.4
1-15/20-250
28.0
31.5
12000
57
238
990
840
1755
240
50
10.5
18
28
380-415V, 50Hz, 3
8.54
8.95
8
15.1
1-16/20-250
WR2-SERIES WITH WATER COOLED HEAT EXCHANGER (ONLY FOR INDOOR USE)
MODEL REFERENCE
PQRY-P200YMF-C
CAPACITY (kW)
City Multi WR2:
PQRY-P200/250 YMF-C
Note:
1) Cooling/heating capacity indicates the maximum value
at operation under the following conditions:
Cooling/outdoor: 35°C DB/24°C WB
Watertemperature WR2 30°C
Heating/outdoor: 7°C DB/6°C WB
Watertemperature WR2 20°C
2) The ambient temperature of heat source units has to be
kept below 40°C DB. The ambient relative humidity of
heat source units has to be kept below 80%
COOLING WATER FLOW RATE
PRESSURE DROP
MAX. PIPING LENGTH**
REFRIGERANT CIRCUIT
MAX. HIGH DIFFERENCE
REFRIGERANT CIRCUIT
CHARGE R407C
NOISE*
WEIGHT
DIMENSIONS (mm)
Cooling
Heating
(m3/h)
(k Pa)
(m)
(m)
(kg)
dB(A)
(kg)
Width
Depth
Height
ELECTRICAL SUPPLY (V, PHASE, Hz)
INPUT POWER (kW)
Cooling
Heating
STARTING CURRENT
(A)
RUNNING CURRENT
(A)
PIPE SIZE ø (mm)
liquid
GAS
OPERATING TEMP. RANGE
COOLING INDOOR
HEATING INDOOR
INDOOR UNITS
NO./TYPE
PQRY-P250YMF-C
22.4
25.0
3.9
8
220
28.0
31.5
4.9
10
220
50
50
7.5
51
270
1150
500
1670
8.5
52
280
1150
500
1670
380-415V, 50Hz, 3
7.6
9.7
7.4
9.4
12
12
12.1
15.5
18
18
28
28
15ºC – 24ºC (WB) / watertemp.10º C – 45º C
15ºC – 27ºC (DB) / watertemp.10º C – 45º C
1-15/20-250
1-16/20-250
BC-CONTROLLER FOR R2/WR2-SERIES
liquid
gas
CMBP104V-F
4
18
28
CMBP105V-F
5
18
28
CMBP106V-F
6
18
28
CMBP108V-F
8
18
28
CMBP1010V-F
10
18
28
CMBP1013V-F
13
18
28
CMBP1016V-F
16
18
28
liquid
gas
10
16
10
16
10
16
10
16
10
16
10
16
10
16
24
648
432
284
27
648
432
284
39
648
432
284
47
1098
432
284
54
1098
432
284
0.07
0.3
0.08
0.36
0.16
0.69
0.2
0.89
0.25
1.08
MODEL REFERENCE
BC-Controller – required
for R2/WR2
** Noise level measured at a position of 1m
in front of the unit.
** one-way
NUMBER OF CONNECTIONS
PIPE SIZE EXT., ø (mm)
BC-Controller at outdoor unit
PIPE SIZE EXT. ø (mm)
Indoor unit at BC-Controller
WEIGHT
DIMENSIONS (mm)
(kg)
Width
Depth
Height
ELECTRICAL SUPPLY, (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
82
29
34
648
648
432
432
284
284
220-240V, 50Hz, 1
0.09
0.13
0.43
0.56
BIG R2-OUTDOOR UNITS
MODEL REFERENCE
CAPACITY (kW)
PURY-P400YMF-C
PURY-P500YMF-C
45,0
56,0
50.0
63,0
22200
22200
60
60
470
500
1990
1990
840
840
1715
1715
250
250
50
50
20
22
28
28
35
35
380-415V, 50Hz, 3
16,3
20.5
15.2
19.0
2-24/20-250
Cooling
Heating
(m3/h)
dB(A)
(kg)
Width
Depth
Height
(m)
(m)
(kg)
liquid
gas
AIRFLOW
NOISE*
WEIGHT
DIMENSIONS (mm)
MAX PIPE LENGTH**
MAX HIGH DIFFERENCE
CHARGE R407C
PIPE SIZE ø (mm)
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(Cooling)
(Heating)
INDOOR UNITS TO INSTALL
No./Type
City Multi Big R2:
PURY-P400/500 YMF-C
** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.
** one-way
MASTER-CONTROLLER FOR BIG R2-SERIES
liquid
gas
CMBP108V-FA
8
28
35
CMBP1010V-FA
10
28
35
CMBP1013V-FA
13
28
35
CMBP1016V-FA
16
28
35
liquid
gas
10
16
10
16
10
16
10
16
MODEL REFERENCE
NUMBER OF CONNECTIONS
PIPE SIZE EXT., ø (mm)
BC-Controller at outdoor unit
PIPE SIZE EXT. ø (mm)
Indoor unit at BC-Controller
PIPE SIZE EXT. ø (mm)
liquid
gas
Master-Controller at Slave-Controller
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY, (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
12
18
28
44
1110
520
289
0.14
0.58
12
12
18
18
28
28
49
57
1110
1110
520
520
289
289
220-240V, 50Hz, 1
0.17
0.23
0.7
0.89
SLAVE-CONTROLLER FOR BIG R2-SERIES
MODEL REFERENCE
NUMBER OF CONNECTIONS
PIPE SIZE EXT., ø (mm)
liquid
gas
Slave Controller at Master Controller
PIPE SIZE EXT. ø (mm)
liquid
gas
Indoor unit at Slave Controller
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY, (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
CMBP108V-FB
8
12
18
28
10
16
12
18
28
64
1110
520
289
MasterController
0.26
1.08
Note: The Slave BC-Controller can
only use in combination with the
Master Controller
SlaveController
32
648
432
284
220-240V, 50Hz, 1
0.128
0.53
83
Indoor Units - Technical Data
PMFY 1-WAY IN-CEILING CASSETTES
MODEL REFERENCE
GRILLE MODEL
CAPACITY (kW)
Cooling
Heating
Low
Middle 1
Middle 2
High
dB(A)
(kg)
Width
Depth
Height**
liquid
gas
AIRFLOW (m3/h)
NOISE* (Low/High)
WEIGHT / incl. Grille
DIMENSIONS (mm) (Grille)
PIPE SIZE ø (mm)
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
RUNNING CURRENT
PMFY-P20VBM-A
PMP-40 BM
2.2
2.5
390
432
480
522
27/35
14 (17)
854 (1000)
395 (470)
230 (30)
6
12
(kW)
(A)
0.042
0.2
PMFY-P25VBM-A
PMFY-P32VBM-A
PMP-40 BM
PMP-40 BM
2.8
3.6
3.2
4.0
438
438
480
480
512
512
558
558
32/37
32/37
14 (17)
14 (17)
854 (1000)
854 (1000)
395 (470)
395 (470)
230 (30)
230 (30)
6
6
12
12
220 – 240 V, 50 Hz, 1
0.044
0.044
0.21
0.21
PMFY-P40VBM-A
PMP-40 BM
4.5
5.0
462
522
582
642
33/39
14 (17)
854 (1000)
395 (470)
230 (30)
6
12
0.054
0.26
* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber
** Needed installation height, in brackets: Visible grille height
PLFY 2-WAY IN-CEILING CASSETTES
PLFYPLFYPLFYP20VLMD-B P25VLMD-B P32VLMD-B
CMP-40
CMP-40
CMP-40
VLW-B
VLW-B
VLW-B
MODEL REFERENCE
GRILLE MODEL
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE* (Low/High)
Cooling
Heating
Low
Middle 1
Middle 2
High
dB(A)
2.2
2.5
390
480
–
570
27 / 33
WEIGHT / incl. Grille
DIMENSIONS (mm)
(Grille)
(kg)
23 (29.5)
Width
776 (1080)
Depth
634 (710)
Height**
338 (20)
PIPE SIZE ø (mm)
liquid
6
gas
12
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(kW)
0.075
RUNNING CURRENT (A)
0.37
2.8
3.2
390
480
–
570
27 / 33
3.6
4.0
390
480
–
570
27 / 33
23 (29.5)
24 (30.5)
776 (1080) 776 (1080)
634 (710) 634 (710)
338 (20)
338 (20)
6
6
12
12
0.075
0.37
0.075
0.37
PLFYPLFYPLFYPLFYPLFYPLFYP40VLMD-B P50VLMD-B P63VLMD-B P80VLMD-A P100VLMD-A P125VLMD-A
CMP-40
CMP-63
CMP-63
CMP-63
CMP-125
CMP-125
VLW-B
VLW-B
VLW-B
LW-F
LW-F
LW-F
4.5
5.0
420
510
–
630
29 / 36
5.6
6.3
540
660
–
750
31 / 37
24 (30.5)
27 (34.5)
776 (1080) 946 (1250)
634 (710)
634 (710)
338 (20)
338 (20)
6
6
12
12
220-240V, 50Hz, 1
0.085
0.086
0.42
0.43
7.1
8.0
600
780
–
930
32 / 39
28 (35.5)
946 (1250)
634 (710)
338 (20)
10
16
9.0
10.0
900
1020
1140
1260
36 / 43
11.2
12.5
1260
1380
1560
1740
37 / 43
14.0
16.0
1440
1620
1800
1980
40 / 46
41 (51)
56 (67.5)
56 (67.5)
1358 (1650) 1708 (2000) 1708 (2000)
606 (670)
606 (670)
606 (670)
338 (8)
338 (8)
338 (8)
10
10
10
16
18
18
0.105
0.51
0.23
1.1
0.25
1.2
0.28
1.35
* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber
** Needed installation height, in brackets: Visible grille height
PLFY 4-WAY IN-CEILING CASSETTES
MODEL REFERENCE
GRILLE MODEL
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE* (Low/High)
WEIGHT / incl. Grille
DIMENSIONS
(Grille)
Cooling
Heating
Low
Middle 1
Middle 2
High
dB(A)
PLFYP32VKM-A
PLP-2.5KC
PLFYP40VKM-A
PLP-2.5KC
PLFYP50VKM-A
PLP-2.5KC
PLFYP63VKM-A
PLP-2.5KC
PLFYP80VAM-A
PLP-6AA
PLFYP100VAM-A
PLP-6AA
PLFYP125VAM-A
PLP-6AA
3.6
4.0
780
840
870
900
31 / 35
4.5
5.0
780
840
870
900
31 / 35
5.6
6.3
780
840
900
960
32 / 37
7.1
8.0
840
900
960
1020
35 / 39
9.0
10.0
960
1080
1200
1320
30 / 37
11.2
12.5
1200
1380
1560
1680
33 / 41
14.0
16.0
1320
1500
1680
1800
35 / 43
19 (22.7)
660 (760)
660 (760)
298 (30)
6
12
19 (22.7)
660 (760)
660 (760)
298 (30)
6
16
24 (29)
840 (950)
840 (950)
258 (30)
10
16
30 (35)
840 (950)
840 (950)
298 (30)
10
18
30 (35)
840 (950)
840 (950)
298 (30)
10
18
0.13
0.6
0.14
0.64
0.18
0.86
0.3
1.43
0.34
1.64
(kg)
19 (22.7)
Width
660 (760)
Depth
660 (760)
Height**
298 (30)
PIPE SIZE ø (mm)
liquid
6
gas
12
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(kW)
0.13
RUNNING CURRENT
(A)
0.6
20 (23.7)
660 (760)
660 (760)
298 (30)
10
16
220-240V, 50Hz,1
0.15
0.68
* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber
** Needed installation height, in brackets: Visible grille height
84
PCFY SUSPENDED INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE*
(Low/High)
WEIGHT
DIMENSIONS (mm)
PIPE SIZE ø (mm)
ELECTRICAL SUPPLY
INPUT POWER
RUNNING CURRENT
Cooling
Heating
Low
Middle 1
Middle 2
High
dB(A)
(kg)
Width
Depth
Hight
liquid
gas
(V, Freq.,Phase)
(kW)
(A)
PCFYP40VGM-A
PCFYP63VGM-A
PCFYP100VGM-A
PCFYP125VGM-A
4.5
5.0
480
600
660
720
29 / 38
7.1
8.0
720
840
960
1080
32 / 39
11.2
12.5
1080
1200
1380
1500
36 / 43
14.0
16.0
1560
1680
1920
2100
37 / 44
27
1000
680
210
6
12
34
1310
680
210
10
16
0.10
0.46
0.13
0.6
37
1310
680
270
10
18
220-240V, 50Hz, 1
0.16
0.73
43
1620
680
270
10
18
0.24
1.1
*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber
PKFY WALL MOUNTED INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW)
AIRFLOW (m3/h)
NOISE*
(Low/High)
WEIGHT
DIMENSIONS (mm)
PKFY-P20VAM-A
Cooling
Heating
Low
Middle 1
Middle 2
High
dB(A)
(kg)
Width
Depth
Height
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
PKFY-P25VAM-A
PKFY-P32VGM-A
PKFY-P40VGM-A
PKFY-P50VGM-A
2.2
2.5
294
312
336
354
32 / 36
2.8
3.2
294
312
336
354
32 / 36
3.6
4.0
480
570
630
690
33 / 41
4.5
5.0
480
570
630
690
33 / 41
5.6
6.3
540
600
660
720
34 / 43
8.5
815
158
295
6
12
8.5
815
158
295
6
12
16
990
235
340
6
12
16
990
235
340
10
16
0.04
0.2
0.04
0.2
16
990
235
340
6
12
220-240V, 50Hz, 1
0.07
0.32
0.07
0.32
0.07
0.32
*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber
85
Indoor Units - Technical Data
PEFY CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, VML WITH FILTER AS STANDARD
PEFYP20VML-A
MODEL REFERENCE
CAPACITY (kW)
Cooling
Heating
AIRFLOW (m3/h)
Low
Middle
High
EXT. STATIC PRESSURE (Pa)
NOISE*
(Low/High) dB(A)
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Hight
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER (kW)
RUNNING CURRENT
(A)
PEFYP25VML-A
PEFYP32VML-A
PEFYP40VMH-A
2.2
2.5
324
390
474
5
29/36
18
720
550
225
6
12
2.8
3.2
324
390
474
5
29/36
18
720
550
225
6
12
3.6
4.0
360
450
570
5
30/40
18
720
550
225
6
12
4.5
5.0
600
–
840
0.05
0.24
0.05
0.24
0.07
0.32
PEFYP50VMH-A
27/34
44
750
900
380
6
12
220-240V, 50Hz, 1
0.19
0.88
PEFYP63VMH-A
PEFYP71 VMH-A
5.6
7.1
6.3
8.0
600
810
–
–
840
1140
50 / 100 /150 / 200
27/34
32/38
44
45
750
750
900
900
380
380
10
10
16
16
8.0
9.0
930
–
1320
32/39
50
1000
900
380
10
16
0.19
0.88
0.26
1.20
0.24
1.12
PEFY CEILING CONCEALED DUCTED (REAR SUCTION) INDOOR UNITS
PEFYP80VMH-A
MODEL REFERENCE
CAPACITY (kW)
Cooling
Heating
AIRFLOW
(Low/High) (m3/h)
EXT. STATIC PRESSURE (Pa)
NOISE*
WEIGHT
DIMENSIONS (mm)
(Low/High) dB(A)
(kg)
Width
Depth
Hight
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER (kW)
(kW)
RUNNING CURRENT
(A)
PEFYP100VMH-A
9.0
10.0
1080/1500
11.2
12.5
1590/2280
35/41
50
1000
900
380
10
16
34/42
70
1200
900
380
10
18
0.32
1.47
0.48
2.34
PEFYP125VMH-A
PEFYP140VMH-A**
14.0
16.0
1590/2280
16.0
18.0
1680/2400
PEFYP200VMH-A**
PEFYP250 VMH-A**
22.4
25.0
3480
50/100/150/200
28.0
31.5
4320
100/130/220/260
34/42
70
1200
900
380
10
18
220-240V, 50Hz, 1
0.48
2.34
34/42
70
1200
900
380
10
18
45***
52***
100
100
1250
1250
1120
1120
470
470
12
12
28
28
380-415V, 50Hz, 3
0.99
1.23
1.62
2.00
0.48
2.35
***The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber
*** Refering to projects. Please ask for delivery times.
*** at 220 PA
PEFY CEILING CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, FILTER AS STANDARD
PEFYPEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY P20VMM-A P25VMM-A P32VMM-A P40VMM-A P50VMM-A P63VMM-A P71VMM-A P80VMM-A P100VMM-A P125VMM-A P140VMM-A
MODEL REFERENCE
CAPACITY (kW)
Heizleistung
AIRFLOW(m3/h)
Cooling
Heating
Low
Middle
High
EXT. STATIC PRESSURE (Pa)
NOISE*
(Low/High) dB(A)
WEIGHT
(kg)
DIMENSIONS (mm)
Width
Depth
Hight
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
2.2
2.5
360
432
510
30/50/100
27 / 32
27
815
700
295
6
12
2.8
3.2
360
432
510
30/50/100
27 / 32
27
815
700
295
6
12
3.6
4.0
450
540
630
30/50/100
28 / 35
27
815
700
295
6
12
4.5
5.0
600
720
840
30/50/100
31 / 37
33
935
700
295
6
12
0.15
0.73
0.15
0.73
0.17
0.81
0.19
0.92
5.6
7.1
6.3
8.0
720
810
870
972
1020
1440
30/50/100 30/50/100
31 / 38
31 / 38
33
42
935
1175
700
700
295
295
10
10
16
16
220-240V, 50Hz, 1
0.2
0.22
0.98
1.07
*The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber
86
8.0
9.0
9.0
10.0
870
870
1080
1080
1260
1260
30/50/100 30/50/100
32 / 39
32 / 39
42
42
1175
1175
700
700
295
295
10
10
16
16
0.25
1.15
0.17
0.82
11.2
12.5
1380
–
1980
50/130
40 / 44
62
1415
740
325
10
18
14.0
16.0
1440
–
2040
50/130
42 / 45
65
1415
740
325
10
18
16.0
18.0
1770
–
2520
50/130
42 / 45
70
1715
740
325
10
18
0.29
1.31
0.4
1.9
0.42
1.95
PFFY FLOOR STANDING (CONCEALED TYPE) INDOOR UNITS
PFFYP20VLRM-A
PFFYP25VLRM-A
PFFYP32VLRM-A
PFFYP40VLRM-A
PFFYP50VLRM-A
PFFYP63VLRM-A
Cooling
Heating
(m3/h)
2.2
2.5
330/390
2.8
3.2
330/390
3.6
4.0
420/540
4.5
5.0
540/660
5.6
6.3
720/840
7.1
8.0
720/930
dB(A)
31 / 37
31 / 37
32 / 37
35 / 40
35 / 40
37 / 43
18.5
886
220
639
6
12
18.5
886
220
639
6
12
20
1006
220
639
6
12
21
1006
220
639
6
12
25
1246
220
639
10
16
27
1246
220
639
10
16
0.04
0.19
0.04
0.19
0.06
0.29
0.085
0.40
0.1
0.46
MODEL REFERENCE
CAPACITY (kW)
AIRFLOW
(Low/High)
NOISE*
(Low/High)
WEIGHT
DIMENSIONS (mm)
(kg)
Width
Depth
Height
PIPE SIZE ø (mm)
liquid
gas
ELECTRICAL SUPPLY (V, Freq., Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
220-240V, 50Hz, 1
0.065
0.32
*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber
PFFY FLOOR STANDING (CABINET TYPE) INDOOR UNITS
MODEL REFERENCE
PFFYP20VLEM-A
PFFYP25VLEM-A
PFFYP32VLEM-A
PFFYP40VLEM-A
PFFYP50VLEM-A
PFFYP63VLEM-A
CAPACITY (kW)
Heizleistung
AIRFLOW
(Low/High)
Cooling
Heating
(m3/h)
2.2
2.5
330/390
2.8
3.2
330/390
3.6
4.0
420/540
4.5
5.0
540/660
5.6
6.3
720/840
7.1
8.0
720/930
NOISE*
(Low/High)
dB(A)
31 / 37
31 / 37
32 / 37
35 / 40
35 / 40
37 / 43
23
1050
220
630
6
12
23
1050
220
630
6
12
25
1170
220
630
6
12
26
1170
220
630
6
12
30
1410
220
630
10
16
32
1410
220
630
10
16
0.04
0.19
0.04
0.19
0.06
0.29
220-240V, 50Hz, 1
0.065
0.32
0.085
0.40
0.1
0.46
WEIGHT
DIMENSIONS (mm)
(kg)
Width
Depth
Height
PIPE SIZE ø (mm)
liquid
Anschlüsse, außen ø (mm) gas
ELECTRICAL SUPPLY (V, Freq.,Phase)
INPUT POWER
(kW)
RUNNING CURRENT
(A)
*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber
87
City Multi
System Control – Standard Remote Control
●
PAR-20MAA
PAR-20 MAA to connect at the indoor unit, building of groups of seperate
Databus System possible
● 1 Indoor unit individual, 1 Group with 16 indoor units possible by two-wire
signal lines
● Easy to read, easy to operate display
● On/Off Timer
● Temperature selection in 1°C units
● Auto-diagnosis display
A microcomputer constantly monitors operation to keep the units running
smoothly. Should problems occure, the temperature setting display changes to
an auto-diagnosis display that shows the inspection mode and the unit address
alternately.
● Room thermometer is built into the remote controller.
Switching possible to indoor unit room thermometer.
●
PAR-F27 MEA
PAR-F27 MEA to connect at the City Multi Databus System, easy to form
groups
● 1 Indoor unit individual / 1 Group with16 indoor units
● Easy to read, easy to operate display
● Extensive time function
● Temperature selection in 1°C units
● Auto-diagnosis display
A microcomputer constantly monitors operation to keep the units running
smoothly. Should problems occure, the temperature setting display changes to
an auto-diagnosis display that shows the inspection mode and the unit address
alternately.
● Room thermometer is built into the remote controller.
Switching possible to indoor unit room thermometer.
● Limit temperature setting
To simplify operation of the system, the range of controls has been limited
to START/STOP, room temperature and fan speed
● The only wiring required is cross-over wiring based on two-wire signal lines
● Room temperature sensors are built-in
The indoor unit can be replaced with body thermostats
● Easy-to-read, easy-to-operate icon display
● Temperature selection
● Can operate all types of indoor units
● Standardized remote controllers for all indoor units
● 1 indoor unit individual/1 group with 16 indoor units
● PAC-SE51 CRA – Grouping addressing by data bus
● PAC-YT51 CRA – Main grouping by two-wire signal lines
●
PAC-SE51 CRA
PAC-YT51 CRA*
Operating
status readout
Exposed type
*Since this system has no operation mode switching, test operation, self-diagnosis or linked
setting functions, it should always be used in conjunction with the PAR-F27MEA or other
centralized controller.
88
City Multi
System Control Accessories – Infrared-, Group- and
System Remote Control
– Timer
PAR-FL31MA
Infrared-Remote Control PAR-FL31 MA and
PAR-FA31 MA (Signal receiver)
●
●
●
PAR-FA31MA
It can operate in a group system without requiring
address settings
When operating, it displays LED lamps. When errors
occure, the error can be shown by the LED flash
count
1 Indoor unit individual/1 group with 16 indoor units
by two-wire signal lines
Group Remote Control PAC-SC30 GRA
●
Easy to read, easy to operate display
Temperature selection in 1°C units
● Auto-diagnosis-display
A microcomputer constantly monitors operation to keep the units running
smoothly. Should problems occure, the temperature setting display changes to
an auto-diagnosis display that shows the inspection mode and the unit address
alternately.
● 8 Indoor units individual / Max. 16 Indoor units in 8 groups
●
PAC-SC30GRA
Programme Timer PAC-YT32 PTA
●
●
●
One-week scheduling by remote controller
Set-back function
Control for PAR-F27 MEA
(1 Indoor unit individual / 1 group with 16 indoor units)
PAC-YT32 PTA
89
City Multi
System Control Accessories – Infrared-, Group- and
System Remote Control
– Timer
On/Off Remote Controller PAC-YT40 ANRA
●
●
Up to 50 groups
Price competitive solution,
up to 50 indoor units
PAC-YT40 ANRA
System Remote Controller PAC-SF44 SRA
●
●
●
●
●
PAC-SF44SRA
●
Control range as Standard Controller (Air Outlet Angle/Air Filter)
Limited room air temperature selection
Auto diagnosis system
50 indoor units individual/max. 50 indoor units with 50 groups
Lock-out function for PAR-F27 MEA
External Input/Output
System Timer PAC-YT34 STA
●
●
●
●
●
PAC-YT34 STA
90
●
Directly connected to the M-Net databus
50 groups/max. 50 indoor units
Timer-controlled mode
Timer-controlled temperature
9 Timer functions
Lock-off selection (On/Off/Mode/Temperatue)
City Multi The New Controller G-50 A
– The Next Controller Generation
●
Simple and flexible
The central controller G-50 A is equally suitable for small and large systems.
●
Web browser
Use a standard web browser on your PC, e.g. Microsoft Internet ExplorerTM,
to operate and monitor the air-conditioning unit, which is connected to your local
Intranet, in comfort.
●
Integrated software
The easy to understand operating software is already integrated in the G-50 A.
This represents Mitsubishi Electric’s own innovation and is not Windows-based.
It is therefore impossible for hackers to spy in your system data.
●
Three password levels
You can safeguard against unauthorised access to the air-conditioning system
on three operating levels which are individually protected by passwords of your
choice.
– Access to an air-conditioning unit (or group) e.g. for each office/floor but
without the possibility to change the system settings
– Access to group and maintenance functions, e.g. for in-house technicians
– Access to the entire system, e.g. for the system administrator
●
Remote access
You can also operate your air-conditioning system with your PC by remote
control via your local intranet or phone connection. The access is protected by
a password of your choice.
●
Automatic alarm
If an error occurs, the G-50 A sends a message with the most important
information to a mobile phone (SMS) or an email to an address of your choice.
●
Always up-to-date
Upgrades with continuously updated special functions are available for the
G-50 A.
Examples: – Energy consumption data for individual cost statements
– Special economy programmes
– Annual schedules
G-50A
HARDWARE FOR G-50A
Pos.
1
2
3
4
5
6
Type
G-50A - Standard
G-50A - Pro
PAC-SC 50 KUA
BTX-1000
PC* with software TG 2000
Watt Hour Meter
Description
Standard central controller for 50 air conditioners
As above G-50 incl. Web function & annual schedule, programmed for clients demand
Power supply unit for G-50
Router according to ME specification & installation is required depending to clients demands
PC according Me specification & installation with OS, Internet Explorer and software TG 2000
Amount of WHM is depend of the project
SOFTWARE FOR G-50A
Web Function
Personal Web RC
Power consumption Ratio
Demand Control I
Demand Control II
Annual Schedule
Data Export
Error scanning function
Auto Alarming
Service
BACnet
PLC
Set free Homepage
Remote Control via PC
Calculate individual cost***
Limit temperature range, optimize indoor-outdoor unit**
Peak Cut*** only connection with PLC + PLC Software
Weekly and Yearly Timer**
Trend Graph***
Monitoring Error History
Auto Alarm function – Error Code mailing
Maintenance Tool function
BACnet Connection
PLC connection direct with G-50 via RJ45
TG 2000
Installation TG 2000 software according customer requirement
* Computer periphery like Monitor, Keyboard, Mouse, Printer from client
** Operation with G-50 or Pos. 5
*** Additional pos. 5 nessassary, for Power consumption ration additional Pos. 6 nessassary
91
City Multi
– Central Remote Control
– LonWorks® Interface
– Maintenance Tool
Lon Works®-Interface
L-MAP02-E
● Easy connection of City Multi Systems through LMAP02-E, the Lon
Works®-M-Net protocol converter, the total system requirements of
engineers and end-users can be met more effectively and simply.
● 1 Lon Works®-Interface manages 50 indoor units.
Maintenance Tool - CMS-MNF-B
● Using Maintenance Tool is the easiest way for
controlling, servicing and operating the City Multi
system. All system information will be displayed
on personal computer* screen based on Windows
Software and settings can be changed.
● In addition, error code numbers are output onto
the display.
● Easy maintenance is assured through the trouble
history printer output and call functions. Besides
ths connection with modem and data transfer is
possible. CMS-MNF-B consists of converter box
and software, RS-232 cable (cross) is needed.
* Windows 3.1 or Windows 95, Pentium 75 MHz or more,
16 MB RAM, free space 10 MB on HDD.
92
City Multi
Accessories
CONTROLS
MODEL REFERENCE
PAC-SF48MA-E
PAC-SE40TS-E
PAC-725AD
PAC-SA88HA-E
PAC-SF46EPA
DESCRIPTION
A to M-Net transmission converter
Temperature sensor
Remote indicator (Pack of 10)
Remote indicator (Pack of 1)
Transmission booster
ACCESSORIES
MODEL REFERENCE
PLFY-P-VKM/VAM-A
PAC-SE06WP-E
PAC-SE01AS-E
PAC-SE60AS-E
Wide panel for PLFY-P32/40/50/63 VKM-A
Space panel for PLFY-P32/40/50/63 VKM-A
Space panel for PLFY-P80/100/125 VAM-A
PAC-SE13FK-E
PAC-SG01KF
High efficiency filter for PAC-SE21TM-E
High efficiency filter for PAC-SG03TM-E
PAC-SE21TM-E
PAC-SG03TM-E
Multifunction casement for PLFY-P32/40/50/63 VKM-A
Multifunction casement for PLFY-P80/100/125 VAM-A
PCFY-P-VGM-A
PAC-SE80KF-E
PAC-SE81KF-E
PAC-SE82KF-E
High efficiency filter for PCFY-P40 VGM-A
High efficiency filter for PCFY-P63/100 VGM-A
High efficiency filter for PCFY-P125 VGM-A
PAC-SE84DM-E
PAC-SE85DM-E
PAC-SE86DM-E
Drain pump for PCFY-P40 VGM-A
Drain pump for PCFY-P63 VGM-A
Drain pump for PCFY-P100/125 VGM-A
PEFY-P-VML/VMH-A
PAC-KE04DM-F
PAC-KE32LAF-F
PAC-KE86LAF
PAC-KE88LAF
PAC-KE89LAF
PAC-KE85LAF
PAC-KE63TB-F
PAC-KE80TB-F
PAC-KE140TB-F
PAC-KE250TB-F
Drain pump for PEFY-P-VMH-A
Replacement filter for PEFY-P20/25/32 VML
Optional filter for PEFY-P40/50/63 VMH
Optional filter for PEFY-P71/80 VMH
Optional filter for PEFY-P100/125/140 VMH
Optional filter for PEFY-P200/250 VMH
Filter box for PEFY-P40/50/63 VMH
Filter box for PEFY-P71/80
Filter box for PEFY-P100/125/140
Filter box for PEFY-P200/250
PEFY-P-VMM-A
PAC-KE03DM-F
PAC-KE32EDF-F
PAC-KE50EDF-F
PAC-KE80EDF-F
PAC-KE125EDF-F
PAC-KE140EDF-F
Drain pump for PEFY-P-VMM-A
Round duct flange for PEFY-P20/25/32 VMM-A
Round duct flange for PEFY-P40/50 VMM-A
Round duct flange for PEFY-P63/71/80 VMM-A
Round duct flange for PEFY-P100/125 VMM-A
Round duct flange for PEFY-P140 VMM-A
PU(H)Y-P/PURY-P-YMF-B/C
PAC-KBU02MT-F
PAC-KBU03MT-F
REFRIGERANT PIPES
CMY-R160-H
CMY-R160-HA
CMY-Y102S-F*
CMY-Y102L-F*
CMY-Y202-F*
CMY-Y302-F*
CMY-Y104-F*
CMY-Y107-F*
CMY-Y1010-F*
CMC-30A
DESCRIPTION
High static pressure motor, 30 PA for PU(H)Y-/PURYP200/250 YMF-C
High static pressure motor, (30) 60 PA for PU(H)Y-/PURYP200/250/315 YEM-A
Junction pipe kit for BC-Controller
Junction pipe kit for BC-Controller 2 x CMY-R160-H
Joint for capacity 160 or below
Joint for capacity from 161 up to 330
Joint for capacity from 331 up to630
Joint for capacity 631 or above
Header (4 branch)
Header (7 branch)
Header (10 branch)
Super Y Kit
*you can use also Standard T-Branch
93
Lossnay Ventilation Systems
with heat recovery
VL-Series/LGH-Series
The sophisticated heat recovery technology of the
Lossnay Element saves energy even while keeping your
room comfortable.
The simultaneous intake/exhaust of air together with
the Lossnay core recovers temperature and humidity
from the room. The system’s benefit is to use the
released cooling or heating energy for fresh air
conditioning.
94
• Ventilation without wasting energy
Ventilation of buildings can waste considerable amounts of
heating or cooling energy. The Lossnay system can utilise a high
percentage of this energy to cut operating costs between 20%
and 50% of the power what would otherwise be required to
maintain a constant temperature.
• Save capital costs too
By utilising this lost energy, the capacity of installed heating and
cooling systems can also be reduced, with a consequent saving
in capital costs of up to 30%. Lossnay units are designed to
keep exhaust air and fresh air completely separate and yet still
achieve an efficiency in the range of 60% to 70%. The fresh air
then enters the room at a similar temperature to be expelled air,
to provide comfortable environmental conditions all year round.
• Lossnay at work - and at home
Lossnay total heat exchange ventilators are available in ranges
for both commercial installations and residential use.
LOSSNAY HEAT EXCHANGE SYSTEM
Stale air expelled outside
Outside air is
drawn in
Stale internal
air recovery
Renewed
internal air
Operating range Lossnay system
VL-Series: t = -10°C bis 40°C, ϕ = 60% max
LGH-Series: t = -10°C bis 40°C, ϕ = 80% max
95
Lossnay VL-Series
Wall Mounted Systems
Model VL-100
LOSSNAY-VL-SERIES
MODEL REFERENCE
ELECTRICAL SUPPLY
(V, PHASE,Hz)
POWER INPUT (W)
AIRFLOW
(m3/h)
NOISE*
dB(A)
EFFICIENCY (%)
WEIGHT (kg)
DIMENSIONS (mm)
DUCT SIZE
VL-100U-E
220-240, 1, 50
Low
High
Low
High
Low
High
Low
High
23
26
65
105
29.5
39
77
70
6.5
620
168
265
2x75ø
Width
Depth
Height
(mm)
To install the units of the Lossnay Series VL-100
only 2 x 75 mm diameter bores are necessary.
Supply and return air ducts and protective caps
against invading rain water are included in delivery.
The units operate very quietly, selection between
2 fan speed levels is possible, the unit will be switched
on/off by pull string.
* The values given in the table for the noise level reflect the levels measured at a position 1 m in
front of and 0.8 m below the unit in anechoic chamber
Lossnay LGH-Series
Ceiling Suspended Systems
Model LGH-40ES-E
LOSSNAY-LGH-SERIES
MODEL REFERENCE
LGH-40ES-E
ELECTRICAL SUPPLY
(V, PHASE,HZ)
220-240, 1, 50
POWER INPUT (W)
low
high
88
138
RUNNING CURRENT (A)
low
high
0.4
0.6
AIRFLOW (m3/h)
low
high
250
400
STATIC PRESSURE (Pa)
low
high
10
40
NOISE* dB(A)
low
high
33
42
TEMPERATURE RECOVERY
(%) EFFICIENCY
low
high
70
60
ENTHALPY RECOVERY
(%) EFFICIENCY
low
high
52
45
WIDTH
DEPTH
HEIGHT
900
693
255
WEIGHT (kg)
25
DIMENSIONS (mm)
DUCT SIZE (mm)
2 x 200 ø
OPTIONAL PARTS
MODEL REFERENCE
PZ-03SLP-E
Switch ON/OFF and Airflow
* The values given in the table for the noise level reflect the levels measured at a
position 1 m in front of and 0.8 m below the unit in anechoic chamber
96
• Compact Design
A mere 255 mm from front to back, this thin design takes
up a minimum of space even when suspended from the
ceiling of an existing building.
• Minimal installation needs
In addition to this lightweight and compact design,
connection to the outdoor unit requires just a 200 mm.
• Saves energy
The simultaneous intake/exhaust of air together with the
Lossnay core recovers temperature and humidity from the
room while ventilating, making this unit both economical
and environmentally friendly.
• A refined design
Designed to eliminate the outflow of air to the space
directly beneath the unit, there is no worry of discomfort
from drafts.
Lossnay LGH-Commercial Series
Models LGH-15 to 200 RX
●
Saves between 20% and 50% of the energy that
would otherwise be lost by ventilation
● Saves up to 30% on initial capital costs of heating and
cooling plant due to Lossnay’s ability to utilise heating or
cooling energy that would otherwise be wasted
● Automatically humidifies or dehumidifies incoming air to match
required interior conditions
● Supply air and exhaust air are kept strictly separated to ensure
inbound air is always fresh
● Supply air is heated or cooled as required to match room
conditions
● Provides comfortable ventilation through introduction of fresh air,
helping to provide a healthy working environment
● Minimal Maintenance
● Easily replaced Lossnay element
LOSSNAY-LGH-SERIES
MODEL REFERENCE
ELECTRICAL SUPPLY
(V,PHASE,Hz)
RUNNING CURRENT
POWER INPUT (W)
AIRFLOW
(m3/h)
STATIC PRESSURE (Pa)*
NOISE**
dB(A)
EFFICIENCY %
WEIGHT (kg)
DIMENSIONS (mm)
(A)
Low
Medium
High***
Low
Medium
High***
Low
Medium
High***
Low
Medium
High***
Low
Medium
High***
Width
Depth
Height
DUCT SIZE (mm)
LGH15RX
LGH25RX
LGH35RX
LGH50RX
220-240,1,50
220-240,1,50
220-240,1,50
220-240,1,50
0.52
52
74
104
120
150
150
25
40
90
21
24
26
80
77
77
19
610
780
275
100ø
0.55
54
91
111
165
250
250
20
40
65
21
25
27
93
78
78
23
735
780
275
150ø
0.82
97
154
169
230
350
350
25
70
150
23
28
31
84
79
79
33
874
888
317
150ø
0.96
123
193
204
350
500
500
30
60
150
24
30
32
82
77
77
38
1016
888
317
200ø
LGH80RX
LGH100RX
220-240,1,50 220-240,1,50
1.8
304
368
392
670
800
800
70
100
140
30
32
34
81
78
78
73
1004
1164
398
250ø
2.3
465
495
500
870
1000
1000
80
100
160
32
34
36
81
79
79
83
1221
1164
398
250ø
LGH150RX
LGH200RX
220-240,1,50
220-240,1,50
3.3
585
670
720
1200
1500
1500
50
100
137
33
36
37
81
79
79
175
1004
1662
800
350ø
4.6
900
995
1000
1400
2000
2000
83
80
137
36
37
39
83
79
79
194
1231
1662
800
350ø
*** Refering to the airflow in the table
*** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber
*** Extra high ventilation step to increase stat. pressure
ACCESSORIES LOSSNAY
MODEL REFERENCE
PZ-41SLB
PZ-52SF
DESCRIPTION
WIRED REMOTE Control for independent operation
Remote Controller for City Multi System
97
MJ-E16PX Dehumidifier
to operate by LCD
• Easy
display
operating modes: low,
• 3high
and auto
Large
water container (6 L)
•
stop by overflow
• Automatic
protection
• Timer: 1 – 9 hours operation
• Air filter
• Display of defrost
• Waterlevel visible
• Hygrostat
of humidity
• Display
(50%, 60%, 70%)
restart after
• Automatic
voltage break
up to 16 litres
• Collects
of moisture in a 24 hours
•
•
•
period
Compact, unobstrusive and
quiet in operation
Low energy consumption
Environment-friendly
refrigerant R134a
Compact and efficient
MJ-E16PX seems unobstrusive and is portable
because of its grip and weight (12.9 kg).
Additional Advantages
the time of drying your clothes on
• Reduces
the line
of a hose possible to transport the
• Installation
condensate water
MJ-E16PX
MJ-E16PX
DEHUMIDIFYING CAPACITY
Litres/24 hours
10°C/70% rel. humidity
27°C/60% rel. humidity
30°C/80% rel. humidity
TECHNICAL DATA
Water container (I)
Auto Stop (I)
Weight (kg)
Dimensions (mm)
Width
Depth
Height
Supply voltage (V, Phase, Hz)
Power consumption (W)
Noise dB(A)
Low
in fan operation
High
Operating temperature
min.
max.
Compressor type
Refrigerant
Colour
98
3.1
9.0
16.0
5.0
5.0
12.9
360
281
569
220-240, 1, 50
280
33
35
1°C
40°C
Rotary
R134 a
white
CONTROL FUNCTIONS
Mode button
Timer button
Control lamp
Tank full lamp
Defrost lamp
Humidity lamp
selects low, high and auto
press to set operation time
1 – 9 hours or permanent
shows adjustment
lights when water tank
needs emptying
light is on during
defrost operation
lights when extremely high
rel. humidity, audible signal for
rel. humidity more than 70%
Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B. V.
The Company reserves the right to make any variation in specification to the equipment described or to withdraw or
replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and
improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general
particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request.
Art. No. 154384
© 05/2004
MITSUBISHI ELECTRIC EUROPE B.V.
AIR CONDITIONING DIVISION
GOTHAER STR. 8
D-40880 RATINGEN
GERMANY
TEL.: +49-2102-486-1800
FAX: +49-2102-486-7910
www.mitsubishi-electric-aircon.de

Similar documents