Series - Mitsubishi Electric
Transcription
Series - Mitsubishi Electric
More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world’s leading technology companies, MITSUBISHI ELECTRIC is committed to providing products and solutions which will enhance the quality of our lives – at home, at work and at play. Our outstanding range of split and multi-split air conditioning systems reflect this philosophy. Whether you are an installer, specifier or user, you will appreciate the combination of quality, energy-efficiency, reliability and ease-of-installation that MITSUBISHI ELECTRIC Environmental Control products offer. New technology, more comfort, more energy-efficiency - high-quality air conditioners of MITSUBISHI ELECTRIC! Product series The program offers you more choice than ever before. So whatever the application - a shopping centre, a hotel, restaurant, shop or even a domestic home - the different product series provide the optimum fit. In-ceiling cassettes Contents Units of the M Series are designed for smaller rooms, each outdoor unit requires up to 4 indoor units. The Mr. Slim Series is applied for middle-sized rooms and is available as single-split and as multi-split system in parallel mode. M-Series Wall mounted systems The City Multi Series convinces with cooling capacity of 14 kW till 84 kW in a refrigerant cycle used for big projects. New technology The inverter technology and new refrigerant R410A enable more energy efficiency. All indoor units can be controlled separately for customised adjustment of temperature. Easy installation The environment-friendly systems of MITSUBISHI ELECTRIC can be installed with minimum work. Space-saving and compact units are available for wall or floor mounting for a flexible planning and design of structures. The air conditioning systems are expandable for subsequent increasing of the capacity at any time. 24 Mr. SlimR407C-Series 26 Floor standing units Ceiling suspended systems Rating conditions COOLING Indoor: 27°C DB / 19°C WB Outdoor: 35°C DB / 24°C WB Outdoor water temperature for WR2 30°C HEATING Indoor: 20°C DB Outdoor: 7°C DB / 6°C WB Outdoor water temperature for WR2 20°C Refrigerant piping length 5 m / 7.5 m* (one way) H = 0 m Sound pressure level measured in anechoic room, at a position 1 m in front of the outdoor unit * For PUH-P8/10MYA and City Multi M-Series Accessories 4 Mr. SlimR410A-Series 62 Power Inverter Mr. SlimSeries Accessories 70 City MultiSeries 74 City MultiSeries Accessories 88 Lossnay Ventilation Series 94 Dehumidifier Above ceiling concealed ducted systems 3 98 M Series Split- and Multi-Split Systems Cooling 2.3 kW - 8.5 kW The outstanding M Series brings legendary Mitsubishi Electric quality to the low-capacity air conditioning class. M Series units are perfect for small living spaces like offices, restaurants and small shops, where their unobtrusive appearance and quiet operation are important advantages. Ultra-energy-efficient M Series systems are designed to give lowest possible running costs, with innovative energy-saving features like `Econo-Cool´, which direct airflow towards room occupants. This can allow set temperatures to be raised by 2°C with no loss in comfort and a 20% gain in energy efficiency. 4 Lowest noise levels With noise levels down to just 21 dB(A) Excellent control features M Series remote controllers incorporate easy-to-use features like `IFeel´ control, which memorises the user`s ideal temperature and recreates it precisely. Multi-splits The M Series includes split system models, running up to four indoor units from one outdoor unit. Plus ... ● Optional high-efficiency air cleaning filters; deodorising and antibacterial Catechin filters available for wallmounted systems ● Rapid room cooling with swing mode feature ● Remote control of five different angles of airflow to reach ideal temperatures in optimum time ● A wide range of indoor units and dual-use units for either floor or ceiling installation ● Quick and easy installation ● Auto restart function ● Winterkit in cooling mode up to -15°C for inverter models and a wind-protected installation Range of M Series ● Cooling Indoor: 21° - 32°C DB 15° - 23°C WB Outdoor: 21° - 43°C DB Non-Inverter models and MXZ-A18 WV -15° - 43°C DB Inverter types ● Heating Indoor: 20° - 27°C DB Outdoor: - 9° - 21°C DB -10° - 15°C WB MSC Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 MS Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 MSC Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 MSH Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 MCF Cooling Only Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MCFH Cooling/Heating Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . 11 MSZ Inverter Single Split Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . 12 SLZ Inverter Cooling/Heating 4-Ceiling Cassette Systems. . . . . . . . . . . . . . . . . . . . . . . . 14 SEZ Inverter Cooling/Heating Ceiling Concealed Systems . . . . . . . . . . . . . . . . . . . . . . . 15 MSX Multi Split Systems Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MXZ Inverter Multi Split Systems Cooling/Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 M SERIES Accessories/Optional Parts/Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5 Series MSC Cooling Only Wall Mounted Systems ● Energy-saving rotary piston compressor ● Extremely quiet operation with noise level of only 25 dB(A)* ● `Swing Mode´-function enables automatically a more natural and comfortable airflow throughout the room ● Factory charged with refrigerant R410A ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● Auto restart function 24 h Timer ● Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses ● Accessories: Additional filters available to keep air fresh, please view page 24 * MCS-A07/09YV MSC COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Low High Low High Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling MAX. PIPE LENGTH MAX. HEIGHT DIFFERENCE CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) MSC-A09YV 2.55 306 474 25 36 9 815 244 278 Width Depth Height (m) (m) (kg) Liquid Gas 0.17 MU-A07YV 0.17 MU-A09YV 0.715 0.795 1.14 1686 1686 1914 45 34 780 255 540 20 10 0.60 6 10 45 34 780 255 540 20 10 0.60 6 10 49 36 780 255 540 25 10 0.75 6 12 0.19 MU-A12YV 220-240, 1, 50 3.00 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 6 MSC-A12YV 3.5 324 582 26 40 10 815 244 278 220-240, 1, 50 AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MSC-A07YV 2.3 276 474 25 36 9 815 244 278 3.32 4.92 Series MS Cooling Only Wall Mounted Systems ● Energy-saving rotary piston compressor ● Compact indoor units - easy to install ● `Swing Mode´-function enables automatically a more natural and comfortable airflow throughout the room ● Factory charged with refrigerant R410A ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● Auto restart function 24 h Timer ● Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses ● Accessories: Additional filters available to keep air fresh, please view page 24 MS COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (KW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (MM) MAX. PIPE LENGTH MAX. HEIGHT DIFFERENCE CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A)) Cooling Low High Low High Width Depth Height MS-A18WV 5.0 528 768 34 42 16 1100 227 325 MS-A24WV 6.5 588 768 37 45 16 1100 227 325 MS-A30WV 8.5 684 960 37 47 16 1100 227 325 220-240, 1, 50 0.30 MU-A18WV Cooling Width Depth Height (m) (m) (kg) Liquid Gas 0.30 MU-A24WV 0.34 MU-A30WV 1.81 2.48 3.26 2196 2760 2940 52 44 850 290 605 25 10 1.40 6 12 53 60 850 290 605 25 10 1.90 6 16 55 85 840 330 850 30 15 2.30 10 16 220-240, 1, 50 7.93 10.39 14.42 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 7 Series MSC Cooling/Heating Wall Mounted Systems ● True comfort year-round Compact indoor units easy to install ● Extremely quiet operation with noise level of only 25 dB(A)* ● `Swing Mode´-function for a quick cooling and comfortable airflow throughout the room ● Energy-saving rotary piston compressor ● Factory charged with refrigerant R410A ● ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● Auto restart function ● 24 h Timer ● Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 * MSC-A07/09YV MSC COOLING/HEATING - WALL MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) Width Depth Height MSC-A07YV 2.3 2.5 276 474 25 36 9 815 244 278 Cooling Heating 0.17 MUH-A07YV 0.715 0.69 0.17 MUH-A09YV 0.795 0.84 0.19 MUH-A12YV 1.09 1.08 1686 1710 1710 47 35 780 255 540 20 10 0.62 6 10 49 38 780 255 540 20 10 1.00 6 10 49 40 780 255 540 25 10 1.00 6 12 Cooling Heating Low High Low High MAX. PIPE LENGTH MAX. HEIGHT DIFFERENCE CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) MSC-A12YV 3.5 3.9 324 582 26 40 10 815 244 278 220-240, 1, 50 AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MSC-A09YV 2.55 3.05 306 474 25 36 9 815 244 278 Width Depth Height (m) (m) (kg) Liquid Gas 220-240, 1, 50 3.00 3.32 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 8 4.65 Series MSH Cooling/Heating Wall Mounted Systems ● True comfort year-round Compact indoor units easy to install ● `Swing Mode´-function for a quick cooling and comfortable airflow throughout the room ● Energy-saving rotary piston compressor ● Factory charged with refrigerant R410A ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● Auto restart function ● 24 h Timer ● ● Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 MSH COOLING/HEATING – WALL MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h)) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h)) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH MAX. HEIGHT DIFFERENCE CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Width Depth Height MSH-A18WV 5.0 5.2 528 768 34 42 16 1100 227 325 Cooling Heating 0.30 MUH-A18WV 1.78 1.61 0.30 MUH-A24WV 2.41 2.48 0.34 MUH-A30WV 3.26 3.43 2196 2760 2940 52 47 850 290 605 25 10 1.75 6 12 53 74 840 330 850 25 10 2.15 6 16 55 87 840 330 850 30 15 2.30 10 16 Cooling Heating Low High Low High MSH-A24WV 6.3 7.2 588 768 37 45 16 1100 227 325 MSH-A30WV 8.5 9.4 684 960 37 47 16 1100 227 325 220-240, 1, 50 Width Depth Height (m) (m) (kg) Liquid Gas 220-240, 1, 50 7.93 10.39 14.42 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 9 Series MCF Cooling Only Floor or Ceiling Mounted Systems ● Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension ● Hand-held controller with `fuzzy logic´ control ● Lightweight and compact design for easy installation ● Readily access for pipe connections and maintenance ● Quiet operation noise ● Adjustment of five different angles of airflow direction ● Three fan-stages or automatic set-up angles of airflow direction ● `Swing Mode´-function for a quick cooling and comfortable airflow throughout the room ● Factory charged with refrigerant R410A ● Auto restart function ● 24 h Timer Accessories: Additional filters available to keep air fresh, please view page 24 MCF COOLING ONLY - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HeightNDIFFERENZ (m) CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE,Hz) RUNNING CURRENT (A) Cooling Low High Low High Width Depth Height MCF-A12WV 3.5 474 678 34 44 25 1100 180 650 MCF-A18WV 4.8 492 780 36 46 25 1100 180 650 MCF-A24WV 6.0 642 840 42 48 25 1100 180 650 220-240, 1, 50 Cooling Width Depth Height (kg) Liquid Gas 0.26 MU-A12YV 0.36 MUCF-A18WV 0.39 MUCF-A24WV 1.16 1.81 2.45 1914 2196 2760 49 36 780 255 540 25 10 0.75 6 12 52 44 850 290 605 25 10 1.2 6 12 53 60 850 290 605 25 10 1.8 6 16 220-240, 1, 50 4.89 7.92 10.59 * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 10 Series MCFH Cooling/Heating Floor or Ceiling Mounted Systems ● Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension ● Lightweight and compact design for easy installation ● Comfortable temperature the whole year round ● Quiet operation noise ● Hand-held controller with fuzzy-logic control ● Adjustment of five different angles of airflow direction ● 24 h Timer ● Factory charged with refrigerant R410A ● Readily access for pipe connections and maintenance ● Three fan-stages or automatic set-up angles of airflow direction Accessories: Additional filters available to keep air fresh, please view page 24 MCFH COOLING/HEATING - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW(m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW(m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE CHARGE R410A* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating Low Mittel High Low High Width Depth Height MCFH-A12WV 3.5 3.7 492 636 780 36 46 25 1100 180 650 MCFH-A18WV 4.8 5.0 570 696 840 39 48 25 1100 180 650 MCFH-A24WV 6.0 6.8 642 744 840 42 48 25 1100 180 650 220-240, 1, 50 Cooling Cooling Heating Width Depth Height (m) (kg) Liquid Gas 0.30 MUH-A12YV 1.16 1.02 0.36 MUCFH-A18WV 1.81 1.89 0.36 MUCFH-A24WV 2.45 2.72 1710 2196 2760 49 40 780 255 540 25 10 1.0 6 12 52 47 850 290 605 25 10 1.75 6 12 53 74 840 330 850 25 10 2.15 6 16 220-240, 1, 50 4.85 8.01 10.51 * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 11 Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems ● Compact indoor units easy to install ● Easy and quick cleaning with `Quick Clean Body´-system ● Extremely quiet operation with noise level of only 21 dB(A) (MSZ-A09YV) ● Energy-saving inverter technology provides highest comfort year-round ● `Swing Mode´-function for a quick cooling and comfortable airflow throughout the room ● Factory charged with refrigerant R410A ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● 24 h Timer ● Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses ● Winterkit in cooling mode up to -15° C, view page 5 Accessories: ● Additional filters available to keep air fresh, please view page 24 ● Quick clean kit for connection to household vacuum cleaner MSZ INVERTER SINGLE-SPLIT, COOLING/HEATING INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW(m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MSZ-A09YV 2.5 (0.9 - 3.2) 3.2 (0.9 - 5.0) 222 504 21 37 9 815 244 278 Cooling Heating 0.17 MUZ-A09YV 0.67 0.84 0.19 MUZ-A12YV 1,09 1.08 1900 1900 46 33 800 285 550 20 12 0.80 6 10 47 34 800 285 550 20 12 0.90 6 10 Cooling Heating Low High Low High MSZ-A12YV 3.5 (1.0 - 4.1) 4.0 (0.9 - 6.0) 288 630 22 39 10 815 244 278 220-240, 1, 50 Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) 220-240, 1, 50 3.3 5.0 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 12 Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems ● Compact indoor units easy to install ● Easy and quick cleaning with `Quick Clean Body´-system ● Energy-saving inverter technology provides highest comfort year-round ● `Swing Mode´-function for a quick cooling and comfortable airflow throughout the room ● Factory charged with refrigerant R410A ● Hand-held controller with `fuzzy logic´ control ● Remote control for five different angles of airflow direction ● 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses ● Winterkit in cooling mode up to -15° C, view page 5 ● Accessories: Additional filters available to keep air fresh, please view page 24 MSZ INVERTER SINGLE SPLIT, COOLING/HEATING INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MSZ-A18YV 5.0 (0.9 - 5.9) 6.25 (0.9 - 7.8) 486 828 32 47 16 1100 258 325 Cooling Heating 0.3 MUZ-A18YV 1.56 1.73 0.3 MUZ-A24YV 1.99 2.05 0.34 MUZ-A26YV 2,35 2.65 2940 2940 2940 55 72 840 330 850 30 15 1.80 6 12 55 72 840 330 850 30 15 2.20 6 16 55 80 840 330 850 30 15 2.35 10 16 Cooling Heating Low High Low High MSZ-A24YV 6.0 (0.9 - 6.7) 7.0 (0.9 - 8.1) 510 1020 33 47 16 1100 258 325 MSZ-A26YV 7.1 (0.9 - 8.1) 8.5 (0.9 - 9.5) 552 1020 33 47 16 1100 258 325 220-240, 1, 50 Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE,Hz) RUNNING CURRENT (A) 220-240, 1, 50 6.9 8.8 11.0 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) Units available approx. July/August 2004 13 Series SLZ Inverter Cooling/Heating In-Ceiling Cassette Systems ● The standardised Euro-spacing ● Equipped with drain pump, facilitates installation in existing delivery height 500 mm inserted ceilings ● Fresh air intake ● The required installation height ● Infrared controller with is only 235 mm 12-hours on/off-timer ● Quiet operation with noise level ● Auto restart function of only 32 dB(A)* ● Factory charged with R410A ● Low weight of 16.5 kg - easy ● Winterkit in cooling mode up to install to -15° C, view page 5 ● Best airflow adjustment by three fan stages * SLZ-A09AR ● Long-life filters to keep air fresh, cleaning necessary only after 2,500 hours of normal operation SLZ INVERTER COOLING/HEATING - IN-CEILING CASSETTE SYSTEMS INDOOR UNIT GRILLE CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (KG) DIMENSIONS (mm) Indoor unit DIMENSIONS (mm) Grille ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Heating Low Middle High Low High (kg) Width Depth Height* Width Depth Height** SLZ-A09AR SLP-2AL 2.5 (0.9 - 3.2) 3.0 (0.9 - 3.7) 480 540 600 32 38 16.5/19.5 570 570 235 650 650 20 SLZ-A12AR SLP-2AL 3.2 (1.0 - 4.1) 3.8 (0.9 - 4.8) 540 600 660 34 39 16.5/19.5 570 570 235 650 650 20 Cooling Heating 0.4 SUZ-A09VR 0.76 0.87 0.6 SUZ-A12VR 1.06 1.07 0.62 SUZ-A18VR 1.53 1.50 1900 1900 2940 46 33 800 285 550 20 12 0.8 6 10 47 34 800 285 550 20 12 0.9 6 10 55 72 840 330 850 30 15 1.4 6 12 220-240, 1, 50 Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A*** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) 220-240, 1, 50 3.7 *** Required installation height *** Visible height of grille *** Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber (cooling mode) 14 SLZ-A18AR SLP-2AL 4.3 (0.9 - 5.0) 4.8 (0.9 - 5.6) 540 600 660 35 40 16.5/19.5 570 570 235 650 650 20 4.9 7.4 Series SEZ Inverter Cooling/Heating Ceiling Concealed Systems ● Quiet operation of indoor and outdoor units ● Compact, easy-to-install design (only 270 mm height) ● Low power consumption for economy of use ● Direct driven, forward curved centrifugal fan for maximum air throw ● Self diagnostic trouble shooting function ● Air intake options for entry at back or base of indoor unit ● High quality remote control with service display and 12 h-timer ● Factory charged with refrigerant R410A ● Auto restart function ● Winterkit in cooling mode up to -15°, view page 5 ● Air filters PAC-1000 FT included in delivery SEZ INVERTER COOLING/HEATING - CEILING CONCEALED SYSTEMS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) Cooling Heating Low High EXTERNAL STATIC PRESSURE (Pa) NOISE dB(A) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating 3 AIRFLOW (m /h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE* R410A (kg) PIPE SIZE Liquid Gas Ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) SEZ-A12AR 3.4 (1.0 - 4.3) 3.9 (0.9 - 4.9) 600 780 SEZ-A18AR 4.7 (0.9 - 5.6) 5.7 (0.9 - 6.6) 720 1020 SEZ-A24AR 5.4 (0.9 - 6.1) 6.5 (0.9 - 7.4) 720 1200 30 (50) 30 35 33.5 1100 700 270 30 (50) 31 39 33.5 1100 700 270 30 (50) 32 43 33.5 1100 700 270 220-240, 1, 50 0.59 SUZ-A12VR 1.10 1.11 1900 47 34 800 285 550 20 12 0.8 6 10 0.68 SUZ-A18VR 1.67 1.78 1900 55 72 840 330 850 30 15 0.9 6 12 0.95 SUZ-A24VR 1.92 2.02 2196 55 72 840 330 850 30 15 1.4 6 16 220-240, 1, 50 5.0 8.0 9.0 * Factory charged to 7 m pipe length, for further information please view page 25 The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 15 Series MSX Multi-Split Cooling Only Wall Mounted Systems Advantages: ● Cooling capacity between 2.8 kW and 7.3 kW per outdoor unit ● Up to four wall mounted indoor units with different capacity can be connected for cooling 2, 3 or 4 rooms ● Independent infrared controller with 24-hours on/off-timer ● Expandable system, units can be added at any time ● Multi-Split configurations provide greater economy and comfort due to quiet operation noise, MSC-A07/09 YV only 25 dB(A) ● The energy-saving rotary compressor enables quiet economical performance ● Auto restart function ● Refrigerant R410A MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) MSC-A07YV Cooling Low High Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height* ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) POWER CONSUMPTION (W) PIPE SIZE Liquid ø (mm) Gas MSC-A09YV MSC-A12YV Depending on combinations, view pages 17-19 276 474 25 36 9 815 244 278 0.17 35 6 10 306 474 25 36 9 815 244 278 220-240, 1, 50 0.17 35 6 10 324 582 26 40 10 815 244 278 0.19 40 6 12 COMBINATION WITH 2 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT CAPACITY (kW) CONNECTABLE INDOOR UNITS AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Number Type Width Depth Height TOTAL PIPE LENGTH (m) MAX. PIPE LENGTH per indoor unit (m) MAX. HEIGHT DIFFERENCE DIFFERENCE (m) COMPRESSORS (pc) CHARGE R410A (kg)* Quantity Apportionment Charge for (m) Apportionment PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, Phase, Hz) RUNNING CURRENT (A) POWER CONSUMPTION (kW) MUX-A10WV 2.8 1-2 2 x 07 1914 49 35 780 255 540 30 15 MUX-A19WV 5.9 1-2 1 x 07 + 1 x 12 2460 52 66 840 330 640 30 15 MUX-A25WV 7.0 1-2 2 x 12 2460 52 68 840 330 640 30 15 10 10 10 1 0.90 (2 x 0.7) – 10 (2 x 0.7) – 2x6 2 x 10 2 0.95 (12) 0.95 (12) 7 (12) 7 (12) 2x6 2 x 12 3.59 2 1.0 (12) 0.8 (07) 7 (12) 7 (07) 2x6 1 x 10/ 1 x 12 220-240, 1, 50 9.32 0.8 2.08 2.64 11.87 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 16 Series MSX Multi-Split Systems Cooling Only 2 Wall Mounted Indoor Units Twin Combination: MSX-A10WV ● ● 2.8 kW cooling capacity up to 2 connectable indoor units 2 x MSC-A07YV MSC-A07YV COOLING CAPACITY (kW) OPERATION MUX-A10WV 1 indoor unit MSC-A07YV INDOOR UNIT INDOOR UNIT MSC-A07YV MSC-A07YV 2.40 – – 2.40 1.40 2 indoor unit MSX-A19WV 1.40 ● 5.9 kW cooling capacity ● up to two connectable indoor units 1 x MSC-A07YV 1 x MSC-A12YV MSC-A12YV COOLING CAPACITY (kW) OPERATION MUX-A19WV 1 indoor unit MSC-A07YV INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A07YV 3.50 – – 2.40 3.50 2 indoor unit MSX-A25WV 2.40 ● 7.0 kW cooling capacity ● up to two connectable indoor units 2 x MSC-A12YV MSC-A12YV COOLING CAPACITY (kW) OPERATION MUX-A25WV MSC-A12YV 1 indoor unit 2 indoor unit INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV 3.50 – – 3.50 3.50 3.50 17 Series MSX Multi-Split Systems Cooling Only 3 or 4 Wall Mounted Indoor Units MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) MSC-A07YV Cooling Low High Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) POWER CONSUMPTION (W) PIPE SIZE Liquid ø (mm) Gas MSC-A09YV MSC-A12YV Depending on combinations, view pages 17-19 276 474 25 36 9 815 244 278 0.17 35 6 10 306 474 25 36 9 815 244 278 220-240, 1, 50 0.17 35 6 10 324 582 26 40 10 815 244 278 0.19 40 6 12 COMBINATION WITH 3 OR 4 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT CAPACITY (kW) CONNECTABLE INDOOR UNITS AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Number Type Width Depth Height TOTAL PIPE LENGTH (m) MAX. PIPE LENGTH per indoor unit (m) MAX. HEIGHT DIFFERENCE (m) COMPRESSORS (pc) CHARGE R410A (kg)* Quantity Apportionment Charge for (m) Apportionment PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, Phase, Hz) RUNNING CURRENT (A) POWER CONSUMPTION incl. indoor units (kW) MUX-A20WV 6.0 1-3 3 x 09 2460 52 65 840 330 640 45 15 MUX-A22WV 6.5 1-3 2 x 07 + 1 x 12 2460 52 67 840 330 640 45 15 MUX-A26WV 7.3 1-4 2 x 09 + 2 x 12 2760 52 77 840 330 850 60 15 10 10 10 2 0.80 (09) 1.0 (2 x 09) 7 (09) 10 (2 x 09) 3x6 3 x 10 2 1.05 (2 x 09) 1.05 (2 x 12) 10 (2 x 09) 10 (2 x 12) 4x6 2 x 10 / 2 x 12 8.92 2 0.85 (12) 0.85 (2 x 07) 7 (12) 10 (2 x 07) 3x6 2 x 10 / 1 x 12 220-240, 1, 50 8.92 1.99 1.98 2.36 10.47 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 18 TRIPLE COMBINATION: MSX-A20WV MSC-A09YV ● 6.0 kW cooling capacity ● up to 3 connectable indoor units 3 x MSC-A09YV COOLING CAPACITY (kW) MUX-A20WV MSC-A09YV MSC-A09YV OPERATION INDOOR UNIT MSC-A09YV INDOOR UNIT INDOOR UNIT MSC-A09YV MSC-A09YV 1 indoor unit 2.60 – – – 2.90 – – – 2.90 2 indoor unit 2.60 2.60 – 2.80 – 1.75 – 2.80 2.00 2.50 1.75 1.75 3 indoor unit MSX-A22WV ● ● MSC-A12YV 6.5 kW cooling capacity up to 3 connectable indoor units 1 x MSC-A12YV 2 x MSC-A07YV COOLING CAPACITY (kW) MUX-A22WV MSC-A07YV OPERATION INDOOR UNIT MSC-A12YV 1 indoor unit 3.50 – – – 2.40 – – – 2.40 2 indoor unit 3.50 3.50 – 2.40 – 1.45 – 2.40 1.45 3 indoor unit 3.40 1.45 1.45 MSC-A07YV MSX-A26WV ● ● MSC-A12YV INDOOR UNIT INDOOR UNIT MSC-A07YV MSC-A07YV 7.3 kW cooling capacity up to 4 connectable indoor units 2 x MSC-A12YV 2 x MSC-A09YV COOLING CAPACITY (kW) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV MSC-A09YV MSC-A09YV MUX-A26WV MSC-A12YV 1 indoor unit 3.40 – – – – 3.40 – – – – 2.75 – – – – 2.75 2 indoor unit 1.95 3.40 3.40 – – – 1.95 – – 3.40 3.40 – – 2.70 – 2.70 – 1.70 – – 2.70 – 2.70 1.70 3 indoor unit 1.95 1.95 3.40 – 1.95 1.95 – 3.40 2.80 – 1.70 1.70 – 2.80 1.70 1.70 4 indoor unit 1.95 1.95 1.70 1.70 MSC-A09YV MSC-A09YV 19 Series MXZ Inverter Multi-Split Systems Cooling/Heating Energy-saving inverter technology provides highest comfort year-round ● Very quiet operation ● Factory charged with R410A ● Can operate with up to four indoor units connected ● Various indoor units available: Wall mounted systems, floor or ceiling mounted systems, ceiling concealed system and in-ceiling cassette system ● ● Combination of indoor units with different capacity possible ● Special control retains customised temperature adjustment ● Auto restart function ● Winterkit in cooling mode up to -15° C*, view page 5 * for MXZ-A26/32 WV MXZ INVERTER MULTI-SPLIT SYSTEMS COOLING/HEATING OUTDOOR UNIT CAPACITY (kW) POWER CONSUMPTION incl. indoor units (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Heating Cooling Heating Width Depth Height MAX. PIPE LENGTH per indoor unit (m) TOTAL PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A* (kg) Pipe size Liquid Ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating MXZ-A18WV 5.4 (1.55 - 6.0) 6.6 (1.58 - 7.2) 1.86 (0.37 - 2.13) 1.77 (0.29 - 1.85) 2460 50 52 909 330 640 20 30 MXZ-A26WV 7.2 (2.9 - 8.5) 9.0 (2.6 - 11.0) 2.09 (0.72 - 2.56) 2.15 (0.53 - 3.05) 2630 48 69 900 360 900 25 50 MXZ-A32WV 8.0 (3.7 - 9.2) 9.4 (3.4 - 11.6) 2.19 (0.81 - 2.58) 1.93 (0.59 - 3.23) 2630 48 70 900 360 900 25 70 10 1.75 2x6 2 x 10 10 3.5 3x6 1 x 12 / 2 x 10 220-240, 1, 50 9.18 9.44 10 3.5 4x6 2 x 12 / 2 x 10 8.98 8.55 * Factory charged for max. pipe lengths please view page 25 REMARK: The Multi-Split Systems run either cooling or heating mode. At least two indoor units have to be connected. Possible combinations on page 21, 22 and 23. 20 9.62 8.48 Series MXZ Inverter Multi-Split Systems Cooling/Heating MXZ-A18WV • Wall mounted systems: • Floor or ceiling mounted systems: • Ceiling concealed systems: • In-ceiling cassette systems: Combination Model Mode 07 09 12 07+07 07+09 07+12 09+09 09+12 12 +12 Cooling / HEATING Cooling / HEATING Cooling / HEATING Cooling / HEATING Cooling / HEATING Cooling / HEATING Cooling / HEATING Cooling / HEATING A 2.30 / 3.30 2.50 / 3.60 3.40 / 4.00 2.30 / 3.05 2.30/ 2.97 2.02 / 2.62 2.50 / 3.25 2.20 / 2.78 Cooling / HEATING 2.65 / 3.30 MSC-A07/09/12YV MCFH-A12WV SEZ-A12AR SLZ-A09/12AR, SLP-2AL (Grille) Capacity (kW) B –/– –/– –/– 2.30 / 3.05 2.50 / 3.23 2.98 / 3.88 2.50 / 3.25 3.10 / 3.77 2.65 / 3.30 TOTAL 2.3 (0.90 - 2.95) / 3.30 (0.90 - 4.00) 2.5 (0.90 - 3.30) / 3.60 (0.90 - 4.50) 3.4 (0.90 - 4.00) / 4.00 (0.90 - 4.80) 4.6 (1.49 - 5.30) / 6.10 (1.53 - 6.70) 4.8 (1.49 - 5.40) / 6.20 (1.53 - 6.80) 5.0 (1.51 - 5.60) / 6.50 (1.55 - 7.00) 5.0 (1.51 - 5.55) / 6.50 (1.55 - 7.00) 5.3 (1.53 - 5.80) / 6.55 (1.56 - 7.10) 5.4 (1.55 - 6.00) / 6.60 (1.58 - 7.20) COMBINATION EXAMPLES MXZ-A18WV Please refer to the following table for permitted combinations MSC-A12YV SEZ-A12AR MXZ-A18WV SLZ-A09/12AR SLP-2AL (Grille) MCFH-A12WV MXZ-A18WV 21 MXZ-A26WV Kombination Model 7 9 12 18 24 07+07 07+09 07+12 07+18 07+24 09+09 09+12 09+18 09+24 12+12 12+18 12+24 18+18 18+24 07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+09+09 07+09+12 07+09+18 07+09+24 07+12+12 07+12+18 07+12+24 07+18+18 07+18+24 09+09+09 09+09+12 09+09+18 09+09+24 09+12+12 09+12+18 09+12+24 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+18+18 12+18+24 22 • Wall mounted systems: • Floor or ceiling mounted systems: • Ceiling concealed systems: • In-ceiling cassette systems: Mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating MSC-A07/09/12YV, MSH-A18/24WV MCFH-A12/18/24WV SEZ-A12/18/24AR SLZ-A09/12/18AR (grille SLP-2AL) Capacity (kW) A 2.3 / 3.3 2.5 / 3.6 3.4 / 4.0 5.0 / 7.2 6.0 / 7.9 2.3 / 3.3 2.1 / 3.02 2.1 / 2.69 2.01 / 2.49 1.62 / 2.03 2.5 / 3.6 2.52 / 3.26 2.4 / 3.0 1.96 / 2.45 3.4 / 4.0 2.88 / 3.6 2.4 / 3.0 3.6 / 4.5 3.08 / 3.86 2.3 / 2.9 2.16 / 2.67 1.93 / 2.42 1.58 / 1.96 1.32 / 1.65 2.01 / 2.52 1.8 / 2.25 1.48 / 1.85 1.26 / 1.57 1.62 / 2.03 1.36 / 1.7 1.17 / 1.46 1.17 / 1.46 1.02 / 1.28 2.36 / 3.0 2.16 / 2.7 1.8 / 2.25 1.45 / 1.92 1.97 / 2.45 1.66 / 2.07 1.44 / 1.8 1.44 / 1.8 1.27 / 1.58 2.4 / 3.0 2.05 / 2.57 1.8 / 2.25 1.8 / 2.25 1.6 / 2.0 B C 2.3 / 3.3 2.7 / 3.88 3.6 / 4.61 5.18/ 6.41 5.57 / 6.97 2.5 / 3.6 3.37 / 4.34 4.8 / 6.0 5.23 / 6.55 3.4 / 4.0 4.32 / 5.4 4.8 / 6.0 3.6 / 4.5 4.11 / 5.14 2.3 / 2.9 2.16 / 2.67 1.93 / 2.42 1.58 / 1.96 1.32 / 1.65 2.59 / 3.24 2.31 / 2.89 1.9 / 2.38 1.62 / 2.02 2.79 / 3.48 2.33 / 2.91 2.0 / 2.51 3.01 / 3.76 2.64 / 3.0 2.36 / 3.0 2.16 / 2.7 1.8 / 2.25 1.45 / 1.92 2.61 / 3.27 2.21 / 2.76 1.92 / 2.4 2.88 / 3.6 2.54 / 3.17 2.4 / 3.0 2.05 / 2.57 1.8 / 2.25 2.7 / 3.37 2.4 / 3.0 2.3 / 2.9 2.77 / 3.44 3.32 / 4.15 4.05 / 5.06 4.55 / 5.68 2.59 / 3.24 3.09 / 3.85 3.81 / 4.76 4.32 / 5.4 2.79 / 3.48 3.5 / 4.37 4.01 / 5.02 3.01 / 3.76 3.52 / 4.4 2.36 / 3.0 2.89 / 3.6 3.6 / 4.5 4.11 / 5.14 2.61 / 3.27 3.32 / 4.15 3.84 / 4.8 2.88 / 3.6 3.38 / 4.23 2.4 / 3.0 3.08 / 3.85 3.6 / 4.5 2.7 / 3.37 3.2 / 4.0 Total 2.3 (1.4-3.0) / 3.3 (1.2-4.2) 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 3.4 (1.5-4.3) / 4.0 (1.2-4.8) 5.0 (1.6-5.6) / 7.2 (1.4-8.2) 6.0 (1.6-6.6) / 7.9 (1.4-8.6) 4.6 (2.0-5.4) / 6.6 (1.8-7.2) 4.8 (2.0-5.8) / 6.9 (1.8-8.7) 5.7 (2.0-6.6) / 7.3 (1.8-9.2) 7.2 (2.0-7.7) / 8.9 (1.8-9.9) 7.2 (2.0-8.0) / 9.0 (1.8-9.9) 5.0 (2.0-6.2) / 7.2 (1.8-9.1) 5.9 (2.0-7.3) / 7.6 (1.8-9.5) 7.2 (2.0-8.5) / 9.0 (1.8-10.1) 7.2 (2.0-8.5) / 9.0 (1.8-10.1) 6.8 (2.0-8.5) / 8.0 (1.8-9.8) 7.2 (2.0-8.5) / 9.0 (1.8-10.5) 7.2 (2.0-8.5) / 9.0 (1.8-10.5) 7.2 (2.1-8.5) / 9.0 (1.9-11.0) 7.2 (2.1-8.5) / 9.0 (1.9-11.0) 6.9 (2.9-8.1) / 8.7 (2.6-10.6) 7.1 (2.9-8.5) / 8.8 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 7.2 (2.9-8.5) / 9.0 (2.7-11.0) MXZ-A32WV Combination Model Model 7 9 12 18 24 07+07 07+09 07+12 07+18 07+24 09+09 09+12 09+18 09+24 12+12 12+18 12+24 18+18 18+24 24+24 07+07+07 07+07+09 07+07+12 07+07+18 07+07+24 07+09+09 07+09+12 07+09+18 07+09+24 07+12+12 07+12+18 07+12+24 07+18+18 07+18+24 09+09+09 09+09+12 09+09+18 09+09+24 09+12+12 09+12+18 09+12+24 09+18+18 09+18+24 12+12+12 12+12+18 12+12+24 12+18+18 12+18+24 07+07+07+07 07+07+07+09 07+07+07+12 07+07+07+18 07+07+07+24 07+07+09+09 07+07+09+12 07+07+09+18 07+07+09+24 07+07+12+12 07+07+12+18 07+07+12+24 07+07+18+18 07+09+09+09 07+09+09+12 07+09+09+18 07+09+09+24 07+09+12+12 07+09+12+18 07+09+12+24 07+12+12+12 07+12+12+18 09+09+09+09 09+09+09+12 09+09+09+18 09+09+09+24 09+09+12+12 09+09+12+18 09+12+12+12 12+12+12+12 Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor or ceiling mounted systems: • Ceiling concealed systems: • In-ceiling cassette systems: MSC-A07/09/12YV, MSH-A18/24WV MCFH-A12/18/24WV SEZ-A12/18/24AR SLZ-A09/12/18AR (grille SLP-2AL) Capacity (kW) A 2.3 / 3.3 2.5 / 3.6 3.4 / 4.0 5.0 / 7.2 6.0 / 7.9 2.3 / 3.3 2.1 / 3.02 2.1 / 2.69 2.04 / 2.49 1.75 / 2.12 2.5 / 3.6 2.52 / 3.26 2.5 / 3.0 2.11 / 2.56 3.4 / 4.0 3.1 / 3.76 2.61 / 3.13 3.95 / 4.7 3.42 / 4.03 4.0 / 4.7 2.3 /2.9 2.16 / 2.67 2.07 / 2.53 1.72 / 2.05 1.46 / 1.73 2.04 / 2.49 1.93 / 2.35 1.62 / 1.93 1.4 / 1.64 1.77 / 2.12 1.49 / 1.77 1.3 / 1.53 1.3 / 1.53 1.14 / 1.34 2.36 / 3.0 2.32 / 2.82 1.97 / 2.35 1.71 / 2.01 2.15 / 2.56 1.84 / 2.16 1.6 / 1.88 1.6 / 1.88 1.41 / 1.65 2.65 / 3.13 2.28 / 2.68 2.0 / 2.35 2.0 / 2.35 1.77 / 2.08 1.95 / 2.35 1.83 / 2.19 1.68 / 1.99 1.43 / 1.68 1.24 / 1.46 1.72 / 2.05 1.59 / 1.88 1.36 / 1.6 1.19 / 1.4 1.47 / 1.73 1.27 / 1.49 1.12 / 1.31 1.12 / 1.31 1.62 / 1.93 1.5 / 1.77 1.3 / 1.53 1.14 / 1.34 1.4 / 1.64 1.21 / 1.43 1.07 / 1.26 1.3 / 1.53 1.14 / 1.34 1.97 / 2.35 1.84 / 2.16 1.6 / 1.88 1.41 / 1.65 1.56 / 1.83 1.5 / 1.76 1.6 / 1.88 2.0 / 2.35 B C D 2.3 / 3.3 2.7 / 3.88 3.6 / 4.61 5.25 / 6.41 6.0 / 7.28 2.5 / 3.6 3.37 / 4.34 5.0 / 6.0 5.64 / 6.84 3.4 / 4.0 4.65 / 5.64 5.24 / 6.27 3.95 / 4.7 4.57 / 5.37 4.0 / 4.7 2.3 /2.9 2.16 / 2.67 2.07 / 2.53 1.72 / 2.05 1.46 / 1.73 2.62 / 3.2 2.49 / 3.02 2.09 / 2.48 1.8 / 2.11 3.04 / 3.63 2.56 / 3.04 2.23 / 2.62 3.34 / 3.93 2.93 / 3.45 2.36 / 3.0 2.32 / 2.82 1.97 / 2.35 1.71 / 2.01 2.85 / 3.41 2.46 / 2.89 2.13 / 2.5 3.2 / 3.76 2.82 / 3.31 2.65 / 3.13 2.28 / 2.68 2.0 / 2.35 3.0 / 3.52 2.66 / 3.13 1.95 / 2.35 1.83 / 2.19 1.68 / 1.99 1.43 / 1.68 1.24 / 1.46 1.72 / 2.05 1.59 / 1.88 1.36 / 1.6 1.19 / 1.4 1.47 / 1.73 1.27 / 1.49 1.12 / 1.31 1.12 / 1.31 2.09 / 2.48 1.93 / 2.28 1.67 / 1.96 1.46 / 1.72 1.8 / 2.11 1.56 / 1.83 1.38 / 1.62 2.23 / 2.62 1.95 / 2.3 1.97 / 2.35 1.84 / 2.16 1.6 / 1.88 1.41 / 1.65 1.75 / 2.06 1.5 / 1.76 2.13 / 2.5 2.0 / 2.35 2.3 /2.9 2.77 / 3.44 3.55 / 4.33 4.41 / 5.28 5.03 / 5.93 2.62 / 3.2 3.33 / 4.02 4.18 / 4.97 4.8 / 5.64 3.04 / 3.63 3.84 / 4.57 4.46 / 5.24 3.34 / 3.93 3.91 / 4.6 2.36 / 3.0 3.11 / 3.76 3.95 / 4.7 4.57 / 5.37 2.85 / 3.41 3.69 / 4.33 4.26 / 5.01 3.2 / 3.76 3.76 / 4.42 2.65 / 3.13 3.42 / 4.02 4.0 / 4.7 3.0 / 3.52 3.55 / 4.17 1.95 / 2.35 1.83 / 2.19 1.68 / 1.99 1.43 / 1.68 1.24 / 1.46 2.2 / 2.64 2.04 / 2.41 1.75 / 2.06 1.53 / 1.8 2.52 / 2.96 2.18 / 2.56 1.92 / 2.25 2.88 / 3.38 2.09 / 2.48 1.93 / 2.28 1.67 / 1.96 1.46 / 1.72 2.4 / 2.82 2.08 / 2.45 1.84 / 2.16 2.23 / 2.62 1.95 / 2.3 1.97 / 2.35 1.84 / 2.16 1.6 / 1.88 1.41 / 1.65 2.34 / 2.75 2.0 / 2.35 2.13 / 2.5 2.0 / 2.35 1.95 / 2.35 2.36 / 2.82 2.91 / 3.41 3.69 / 4.33 4.26 / 5.01 2.2 / 2.64 2.72 / 3.22 3.51 / 4.12 4.08 / 4.8 2.52 / 2.96 3.27 / 3.84 3.84 / 4.51 2.88 / 3.38 2.09 / 2.48 2.59 / 3.04 3.34 / 3.93 3.91 / 4.60 2.4 / 2.82 3.13 / 3.67 3.69 / 4.33 2.23 / 2.62 2.93 / 3.45 1.97 / 2.35 2.46 / 2.89 3.2 / 3.76 3.76 / 4.42 2.34 / 2.75 3.0 / 3.52 2.13 / 2.5 2.0 / 2.35 Total 2.3 (1.4-3.0) / 3.3 (1.2-4.2) 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 3.4 (1.5-4.3) / 4.0 (1.2-4.8) 5.0 (1.6-5.6) / 7.2 (1.4-8.4) 6.0 (1.6-6.6) / 7.9 (1.4-8.6) 4.6 (2.0-5.4) / 6.6 (1.8-7.2) 4.8 (2.0-5.8) / 6.9 (1.8-8.7) 5.7 (2.0-6.6) / 7.3 (1.8-9.2) 7.3 (2.0-7.7) / 8.9 (1.8-9.9) 7.75 (2.0-8.0) / 9.4 (1.8-9.9) 5.0 (2.0-6.2) / 7.2 (1.8-9.1) 5.9 (2.0-7.3) / 7.6 (1.8-9.5) 7.5 (2.0-8.5) / 9.0 (1.8-10.1) 7.75 (2.0-8.5) / 9.4 (1.8-10.1) 6.8 (2.0-8.8) / 8.0 (1.8-9.8) 7.75 (2.0-8.8) / 9.4 (1.8-10.5) 7.85 (2.0-8.8) / 9.4 (1.8-10.5) 7.9 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 6.9 (2.9-8.1) / 8.7 (2.6-10.6) 7.1 (2.9-8.6) / 8.8 (2.6-11.1) 7.7 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 7.3 (2.9-8.9) / 8.9 (2.6-11.6) 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.1 (2.9-9.0) / 9.0 (2.6-11.6) 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.8 (3.7-9.2) / 9.4 (3.4-11.6) 7.8 (3.7-9.2) / 9.4 (3.4-11.6) 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 7.85 (3.7-9.2) / 9.4 (3.5-11.6) 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 7.9 (3.7-9.2) / 9.4 (3.4-11.6) 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 7.9 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 23 Series Accessories AIR CLEANING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1300FT 10 MSC-A07/09/12YV MSZ-A09/12YV MAC-1700FT 10 MS(H)-A18/24/30WV MAC-1200FT 10 MCF/MCFH DEODORISING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1700DF 10 MCF/MCFH QUICK CLEAN KIT MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-093SS-E1 1 MSZ-A09/12YV Series Refrigerant Charge OUTDOOR UNITS with R410A • Mostly factory charged to 7 m pipe length (one-way). • Please view the required refrigerant charge for other pipe lengths in the following table. MU-A07/09/12/18/24/30YV/WV OUTDOOR UNITS (MODELS) MU-A07YV MU-A09YV MU-A12YV MU-A18WV MU-A24WV MU-A30WV CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 0.660 0.760 0.860 0.660 0.760 0.860 0.810 0.910 1.010 1.460 1.560 1.660 1.960 2.060 2.160 2.465 2.740 3.015 7m 0.600 0.600 0.750 1.400 1.900 2.300 25 m – – 1.110 1.760 2.260 3.290 30 m – – – – – 3.465 MUH-A07/09/12/18/24/30YV/WV OUTDOOR UNITS (MODELS) MUH-A07YV MUH-A09YV MUH-A12YV MUH-A18WV MUH-A24WV MUH-A30WV CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 0.680 0.780 0.880 1.060 1.160 1.260 1.060 1.160 1.260 1.810 1.910 2.010 2.210 2.310 2.410 2.465 2.740 3.015 7m 0.620 1.000 1.000 1.750 2.150 2.300 25 m – – 1.360 2.110 2.510 3.290 30 m – – – – – 3.565 MUCFH-A18/24WV OUTDOOR UNITS (MODELS) MUCFH-A18WV MUCFH-A24WV 24 7m 1.850 2.200 CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 1.910 2.010 2.110 2.260 2.360 2.460 25 m 2.210 2.560 Series Refrigerant Charge MUZ-A09/12/18/24/26 YV OUTDOOR UNITS (MODELS) MUZ-A 09 YV MUZ-A 12 YV MUZ-A 18 YV MUZ-A 24 YV MUZ-A 26 YV 7m 0.860 0.960 1.800 1.800 2.000 CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 0.950 1.100 1.250 1.050 1.200 1.350 1.860 1.960 2.060 1.860 1.960 2.060 2.165 2.265 2.365 25 m – – 2.160 2.160 2.465 30 m – – 2.260 2.260 2.565 7m 0.860 0.960 1.800 CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 0.950 1.100 1.250 1.050 1.200 1.350 1.860 1.960 2.060 25 m – – 2.160 30 m – – 2.260 SUZ-A09/12/18YV OUTDOOR UNITS (MODELS) SUZ-A 09 YV SUZ-A 12 YV SUZ-A 18 YV MUX-A10/19/25/20/22/26WV OUTDOOR UNITS (MODELS) Compressor Indoor Units Models 7m CHARGE (ONE-WAY) in kg 10 m 15 m 20 m 25 m 30 m MUX-A10WV MUX-A19WV 1 1 1 2 X MSC-A07YV 1 X MSC-A12YV 1 X MSC-A09YV – 1.000* 0.800* 0.900* 1.060 0.860 0.950 1.160 0.960 1.000 – – 1.050 – – 1.100 – – MUX-A25WV 1 1 1 X MSC-A12YV 1 X MSC-A12YV 0.950* 0.950* 1.010 1.010 1.110 1.110 – – – – – – MUX-A20WV 1 1 1 X MSC-A09YV 2 X MSC-A09YV 0.800* – 0.860 1.000* 0.960 1.050 – 1.100 – 1.150 – 1.200 MUX-A22WV 1 1 1 X MSC-A12YV 2 X MSC-A07YV 0.850* – 0.910* 0.850* 1.010 0.900 – 0.950 – 1.000 – 1.050 MUX-A26WV 1 1 2 X MSC-A09YV 2 X MSC-A12YV – – 1.050* 1.050* 1.100 1.100 1.150 1.150 1.200 1.200 1.250 1.250 * Factory charged MXZ-A18/26/32WV OUTDOOR UNITS (MODELS) MXZ-A18WV MXZ-A26WV MXZ-A32WV 20 m 1.750 – – 25 m 1.850 – – CHARGE (ONE-WAY) in kg 30 m 40 m 50 m 1.950 – – 3.500 3.600 3.700 3.500 3.600 3.700 60 m – – 3.900 70 m – – 4.100 25 25 Mr. Slim Series Split- and Multi-Split Systems, R407C Cooling 3.15 kW - 26.0 kW The Mr. Slim Series offers a huge choice of components and configurations for a wide range of applications. The packaged air conditioners are adapted for middlesized rooms, shops, restaurants and offices - for cooling only or with heat pump-function. With ceiling cassettes, ceiling suspended units, wall mounted units and ceiling ducted units, there is a Mr. Slim model which provides the optimum fit for your next job. 26 Advantages of Mr. Slim ● Wide range of indoor units ● Simultaneous operation of 2, 3 or 4 indoor units ● Standard long-life filters ● Auto change over between cooling and heating mode ● Heat pump with warm start system ● Indoor units without electrical heater connectable to heat pump outdoor units ● A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units. ● Wired or infrared remote controller optional ● Maintenance Tool for control and service ● All models can be interfaced to Building Management Systems by Lon Works Interface ● Lossnay heat exchange ventilators connectable ● Factory charged with R407C ● Winter kit as standard, cooling up to -15° Rating conditions Mr. Slim Series* R407C: ● Cooling Indoor: 19°C - 35°C DB 15°C - 22.5°C WB Outdoor: -15°C - 46°C DB ● Heating Indoor: 17°C - 28°C DB Outdoor: -11°C - 24°C DB -12°C - 18°C WB * For PUH-P8/10MYA other rating conditions, please view page 61 COOLING ONLY PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 PLA COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 PCA CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .36 PKA WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 PSA FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 HEAT PUMP UNITS - COOLING AND HEATING PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 PLA/PLH COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . .46 PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 PCA/PCH CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .52 PKA/PKH WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 PSA/PSH FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 PEAD/PEHD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 PEH CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 27 27 Mr. Slim Series PMH Cooling Only 1-Way-In-Ceiling Cassette Systems ● Simple installation and service, ● Factory charged with R407C because of compact dimen● Rotary and scroll compressors sions – installation height only ● Twin, triple and quadruple 230 mm configuration possible ● Wired remote control ● Standard drain pump for 600 ● Precisely directed airflow to mm height differences prevent dirt built-up and stai● External airflow prepared ning of ceiling tiles ● 4 fan-stages for comfortable ● Standard long-life filter and optimum airflow ● Simple installation and easy Accessories: access drain and refrigerant piping connections Optional parts on page 70 and the following 28 28 PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT incl. Grille DIMENSIONS (mm) Indoor unit DIMENSIONS (mm) Grille Cooling Low Middle 1 Middle 2 High Low High (kg) Width Depth Height* Width Depth Height** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling PMH-P1.6 BA 4.4 420 480 540 600 34 40 14/17 854 395 230 1000 470 30 220-240, 1, 50 PMH-P2 BA 5.4 480 540 600 660 36 42 14/17 854 395 230 1000 470 30 220-240, 1, 50 0.29 PU-P1.6 YGAA 0.29 PU-P2 YGAA 1.6 2700 2.3 3300 47 55 900 350 650 40 40 2.5 10 16 380-415, 3, 50 48 71 900 350 855 40 40 2.6 10 16 380-415, 3, 50 2.5 3.7 *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, optional charging please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 29 29 Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems ● Wired remote control with 24h-timer ● Compact dimensions ● Simple installation with easy access drain and refrigerant piping connections ● Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles ● Rotary and scroll compressors ● Factory charged with R407C ● Long-life air filter ● Drain pump for 500 mm height difference 30 ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Space panel enables installation into ceiling void of just 258 mm depth ● Infrared remote control ● High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following Optional PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT incl. Grille DIMENSIONS (mm) Indoor unit DIMENSIONS (mm) (Grille) Cooling Low Middle 1 Middle 2 High Low High (kg) Width Depth Height* Width Depth Height** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling PLA-P1.6 KA 4.4 780 840 900 960 32 37 19 / 22.7 660 660 298 760 760 30 PLA-P2 KA 5.3 780 840 900 960 32 37 19 / 22.7 660 660 298 760 760 30 PLA-P2.5 KA 6.3 840 900 960 1020 35 39.5 20 / 23.7 660 660 298 760 760 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.64 PU-P1.6 YGAA 0.65 PU-P2 YGAA 0.61 PU-P2.5 YGAA 1.8 2.4 2.6 2700 3300 3000 47 55 900 350 650 40 40 2.5 10 16 48 71 900 350 855 40 40 2.6 10 16 48 82 900 350 855 50 50 3.1 10 16 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 2.5 3.7 4.5 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KC PLP-2.5 KLM *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 31 31 Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems ● Wired remote control or infrared remote control with 24h-timer ● Compact dimensions ● Extremely quiet operation noise, PLA-P3AA just 28 dB(A) ● Weight reduced for PLA-P6AA from 46 kg to only 37 kg ● Great convenience due to four fan-stages ● Drain pump for 850 mm height difference ● Simple installation with easy access drain and refrigerant piping connections ● Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles 32 ● Rotary and scroll compressors ● Factory charged with R407C ● Long-life air filter ● Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth ● High efficiency filter and external airflow ● For detailed descriptions please view on page 70 and the following PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT incl. Grille (kg) DIMENSIONS (mm) Indoor unit DIMENSIONS (mm) (Grille) ELECTRICAL SUPPLY (V, phase, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Low Middle 1 Middle 2 High Low High Width Depth Height* Width Depth Height** PLA-P3 AA 7.8 900 960 1080 1200 28 34 24/29 840 840 258 950 950 30 PLA-P4 AA 9.7 1200 1380 1560 1680 33 41 30/35 840 840 298 950 950 30 PLA-P5 AA 12.8 1320 1500 1680 1800 35 43 30/35 840 840 298 950 950 30 PLA-P6 AA 14.3 1320 1500 1680 1800 37 45 32/37 840 840 298 950 950 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 Cooling 0.81 PU-P3 YGAA 1.25 PU-P4 YGAA 1.43 PU-P5 YGAA 1.6 PU-P6 YGAA Cooling 3.4 3000 3.7 5100 5.0 5700 5.9 6000 49 82 900 350 855 50 50 3.3 10 16 51 96 900 350 1260 50 50 4.0 10 18 55 122 1050 350 1260 50 50 4.6 10 18 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.3 5.6 7.6 9.0 Width Depth Height (kg) Liquid Gas Cooling GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AAM PLP-6 AALM *** Required installation height *** Visible height of grille *** Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 33 Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems ● Wired remote control with 24h-timer ● Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m ● Rotary and scroll compressors ● Factory charged with R407C ● Long-life air filter ● Great convenience due to four fan-stages ● Swing louvres with `Auto Angle´ airflow 34 34 ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● High efficiency filter ● Drain pump ● Infrared remote control For detailed descriptions please view on page 70 and the following Optional PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Low Middle 1 Middle 2 High Low High Width Depth Height PCA-P2 GA 5.4 600 660 720 780 37 42 27 1000 680 210 PCA-P2.5 GA 6.7 840 900 960 1080 37 43 34 1310 680 210 PCA-P3 GA 7.5 840 900 960 1080 37 43 34 1310 680 210 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 PCA-P4 GA 9.7 1200 1260 1380 1500 40 45 37 1310 680 270 PCA-P5 GA 12.4 1620 1800 1920 2040 41 46 43 1620 680 270 PCA-P6 GA 14.3 1620 1800 1920 2040 42 48 45 1620 680 270 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 Cooling 0.43 PU-P2 YGAA 0.55 PU-P2.5 YGAA 0.55 PU-P3 YGAA 0.7 PU-P4 YGAA 1.1 PU-P5 YGAA 1.1 PU-P6 YGAA Cooling 2.4 2.65 3.4 3.64 4.94 5.94 3300 3000 3000 5100 5700 6000 48 71 900 350 855 40 40 2.6 10 16 48 82 900 350 855 50 50 3.1 10 16 49 82 900 350 855 50 50 3.3 10 16 51 96 900 350 1260 50 50 4.0 10 18 55 122 1050 350 1260 50 50 4.6 10 18 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.55 7.6 9.0 Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling 380-415, 3, 50 3.7 380-415, 3, 50 380-415, 3, 50 4.5 5.29 * Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 35 Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens ● The special construction enables easy cleaning of the casing and of all airflow parts ● Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) ● On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air ● 36 Rotary and scroll compressors ● Factory charged with R407C ● Wired remote control with 24h-timer ● Twin configuration possible, on page 72 ● Accessories: Oil mist filter (12 pcs.) PAC-SG 38 KF-E ● For detailed descriptions please view on page 70 and the following PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Low High Low High Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Width Depth Height (kg) Liquid Gas Cooling PCA-P3HA 7.5 1020 1140 34 38 41 1136 650 280 PCA-P5HA 13.0 1800 2280 44 50 56 1520 650 280 220-240, 1, 50 220-240, 1, 50 0.55 1.1 PU-P3YGAA PU-P5YGAA 3.36 4.90 3000 49 82 900 350 855 50 50 3.3 10 16 5700 55 122 1050 350 1260 50 50 4.6 10 18 380-415, 3, 50 380-415, 3, 50 5.29 7.60 * Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 37 Mr. Slim Series PKA Cooling Only Wall Mounted Systems ● Infrared remote control with 24h-timer ● Slim compact units for wall mounting ● Simple installation with easy access drain and refrigerant piping connections ● Rotary and scroll compressors ● Factory charged with R407C ● Easily removable long-life air filter ● PKA-P1.6/2 GAL with four fan-stages 38 ● Swing louvres with “Auto Angle” airflow ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Drain pump ● Wired remote control For detailed descriptions please view on page 70 and the following Optional PKA WALL MOUNTED SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Low Middle 1 Middle 2 High Low High Width Depth Height Cooling Cooling Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling PKA-P1.6 GAL 4.5 540 600 660 720 36 43 16 990 235 340 PKA-P2 GAL 5.6 540 600 660 720 36 43 16 990 235 340 PKA-P2.5 FAL 6.5 900 – – 1200 39 45 24 1400 235 340 PKA-P3 FAL 7.9 900 – – 1200 39 45 24 1400 235 340 PKA-P4 FAL 9.5 1320 – – 1680 41 46 28 1680 235 340 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.33 PU-P1.6 YGAA 0.33 PU-P2 YGAA 0.43 PU-P2.5 YGAA 0.43 PU-P3 YGAA 0.52 PU-P4 YGAA 1.7 2.4 2.7 3.4 3.6 2700 3300 3000 3000 5100 47 55 900 350 650 40 40 2.5 10 16 48 71 900 350 855 40 40 2.6 10 16 48 82 900 350 855 50 50 3.1 10 16 49 82 900 350 855 50 50 3.3 10 16 51 96 900 350 1260 50 50 4.0 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 2.5 3.7 4.5 5.3 5.6 * Factory charged to 20 m pipe length, PU-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 39 Mr. Slim Series PSA Cooling Only Floorstanding units ● Function panel case integrated ● Standard long-life filter ● Twin and triple configuration 24h-timer possible, on page 72 ● Simple installation with easy access drain and refrigerant piping connections Accessories: ● Rotary and scroll compressors Optional parts on page 70 and ● Factory charged with R407C the following ● 40 PSA FLOORSTANDING UNITS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Low High Low High Width Depth Height Cooling Cooling Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling PSA-P3 GA 7.7 900 1080 40 45 43 600 270 1900 PSA-P4 GA 9.7 1440 1860 44 49 51 600 350 1900 PSA-P5 GA 12.4 1560 1920 46 51 51 600 350 1900 PSA-P6 GA 14.0 1620 2100 47 52 53 600 350 1900 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.68 PU-P3 YGAA 1.1 PU-P4 YGAA 1.26 PU-P5 YGAA 1.62 PU-P6 YGAA 3.4 3.8 5.0 5.8 3000 5100 5700 6000 49 82 900 350 855 50 50 3.3 10 16 51 96 900 350 1260 50 50 4.0 10 18 55 122 1050 350 1260 50 50 4.6 10 18 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.3 5.6 7.6 9.0 * Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 41 Mr. Slim Series PEAD Cooling Only Above-Ceiling Concealed Ducted Systems ● Wired remote control with 24h-timer ● Simple installation with easy access drain and refrigerant piping connections ● PEAD-P1.6/2/2.5 EA airflow variable - draw in from the back or underside ● Rotary and scroll compressors ● Factory charged with R407C ● Standard long-life filter 42 ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Drain pump ● Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING ONLY INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) Cooling Low High EXTERNAL STATIC PRESSURE (Pa) NOISE dB(A) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling PEAD-P1.6EA 4.5 660 840 30(70) 34(36) 38(43) 33 935 700 295 PEAD-P2EA 5.6 810 1020 30(70) 36(38) 40(44) 33 935 700 295 PEAD-P2.5EA 6.7 1020 1260 30(70) 37(39) 41(46) 42 1175 700 295 PEAD-P3EA 7.7 1200 1500 70(130**) 37(40) 41(45) 44 1175 740 325 PEAD-P4EA 9.7 1620 2040 70(130**) 41(42) 46(48) 62 1415 740 325 PEAD-P5EA 12.3 2010 2520 70(130**) 44(46) 50(52) 65 1415 740 325 PEAD-P6EA 14.1 2190 2760 70(130**) 46(47) 51(53) 70 1715 740 325 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.55 PU-P1.6YGAA 0.61 PU-P2YGAA 0.7 PU-P2.5YGAA 1.7 PU-P3YGAA 2.6 PU-P4YGAA 2.7 PU-P5YGAA 2.8 PU-P6YGAA 1.8 2700 47 55 900 350 650 40 40 2.5 10 16 2.4 3300 48 71 900 350 855 40 40 2.6 10 16 2.7 3000 48 82 900 350 855 50 50 3.1 10 16 3.4 3000 49 82 900 350 855 50 50 3.3 10 16 3.9 5100 51 96 900 350 1260 50 50 4.0 10 18 4.9 5700 55 122 1050 350 1260 50 50 4.6 10 18 5.9 6000 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3. 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 2.5 3.7 4.5 5.3 5.6 7.6 9.0 ** Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 ** Fan motor optional on page 70 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 43 Mr. Slim Series PMH Cooling / Heating 1-Way-In-Ceiling Cassette Systems ● Simple installation and service because of compact dimensions - installation height only 230 mm ● Wired remote control with 24h-timer ● Quiet operation - only 29 dB(A) at PMH-P1 BA ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles ● Standard long-life filter Easy access drain and refrigerant piping connections ● Factory charged with R407C ● Rotary and scroll compressors ● Drain pump for 600 mm height difference ● External airflow prepared ● 4 fan-stages for comfortable and optimum airflow ● Accessories: Optional parts on page 70 and the following 44 PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT incl. Grille DIMENSIONS (mm) Indoor unit DIMENSIONS (mm) Grille Cooling Heating Low Middle 1 Middle 2 High Low High (kg) Width Depth Height* Width Depth Height** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating PMH-P1 BA 3.15 3.4 378 408 456 540 29 35 14/17 854 395 230 1000 470 30 220-240, 1, 50 PMH-P1.6 BA 4.4 5.0 420 480 540 600 34 40 14/17 854 395 230 1000 470 30 220-240, 1, 50 PMH-P2 BA 5.4 6.25 480 540 600 660 36 42 14/17 854 395 230 1000 470 30 220-240, 1, 50 0.19 0.19 PUH-P1 VGAA 1.15 1.06 2700 0.29 0.29 PUH-P1.6 YGAA 1.6 1.7 2700 0.29 0.29 PUH-P2 YGAA 2.3 2.4 3300 46 50 900 350 650 30 30 1.7 6 12 220-240, 1, 50 47 55 900 350 650 40 40 2.5 10 16 380-415, 3, 50 48 71 900 350 855 40 40 2.6 10 16 380-415, 3, 50 4.9 4.5 2.5 2.6 3.7 3.8 GRILLE-TYPE FOR WIRED REMOTE CONTROL PMP-40 BM *** Required installation height *** Visible installation height *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 45 Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems ● Wired remote control with 24h-timer ● PLH units with additional electrical heating for a warm start and to increase capacity of heat pump ● 4 fan-stages for best comfort ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles ● Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m ● Standard long-life filter ● Simple installation with easy access drain and refrigerant piping connections ● Rotary and scroll compressors ● Factory charged with R407C 46 ● Drain pump for 500 mm height difference ● Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth ● Infrared remote control ● High efficiency filter and external airflow ● For detailed descriptions please view on page 70 and the following Optional PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT INDOOR UNIT WITH ELECTRICAL HEATING CAPACITY (kW) Cooling Heating* AIRFLOW (m3/h) Low Middle 1 Middle 2 High NOISE dB(A) Low High WEIGHT PLA incl. Grille (kg) WEIGHT PLH incl. Grille (kg) DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating* OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling Heating* AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C**** (kg) PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Width Depth Height Liquid Gas Cooling Heating GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLA-P1.6 KA PLH-P1.6 KAH 4.4 5.0 (6.4) 780 840 900 960 32 37 19 / 22.7 20 / 23.7 660 660 298 760 760 30 PLA-P2 KA PLH-P2 KAH 5.3 6.0 (7.4) 780 840 900 960 32 37 19 / 22.7 20 / 23.7 660 660 298 760 760 30 PLA-P2.5 KA PLH-P2.5 KAH 6.3 7.4 (9.5) 840 900 960 1020 35 39.5 20 / 23.7 21 / 24.7 660 660 298 760 760 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.64 0.45 (5.83) PUH-P1.6 YGAA 1.8 1.9 (3.3) 2700 0.65 0.45 (5.83) PUH-P2 YGAA 2.4 2.4 (3.8) 3300 0.61 0.45 (8.75) PUH-P2.5 YGAA 2.6 2.6 (4.7) 3000 47 55 900 350 650 40 40 2.5 10 16 48 71 900 350 855 40 40 2.6 10 16 48 82 900 350 855 50 50 3.1 10 16 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 2.5 2.6 3.7 3.8 4.5 4.3 PLP-2.5 KC PLP-2.5 KLM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 47 Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems ● Wired remote control or infrared remote control with 24h-timer ● PLH units with additional electrical heating for a warm start and to increase capacity of heat pump ● Compact dimensions ● Extremely quiet operation noise, PLA-P3AA just 28 dB(A) ● Weight reduced for PLA-P6AA from 46 kg to only 37 kg ● 4 fan-stages for best comfort ● Drain pump for 850 mm height difference ● Simple installation with easy access drain and refrigerant piping connections ● Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m 48 ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles ● Rotary and scroll compressors ● Factory charged with R407C ● Long-life air filter ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Space panel enables installation into ceiling void of just 258 mm depth ● High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT INDOOR UNIT WITH ELECTRICAL HEATING CAPACITY (kW) Cooling Heating* AIRFLOW (m3/h) Low Middle 1 Middle 2 High NOISE dB(A) Low High WEIGHT PLA incl. Grille (kg) WEIGHT PLA incl. Grille (kg) DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating* OUTDOOR UNIT POWER CONSUMPTION (kW) Cooling Heating* AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C**** PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Width Depth Height (kg) Liquid Gas Cooling Heating GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLA-P3 AA PLH-P3 AAH 7.8 9.3 (11.4) 900 960 1080 1200 28 34 24/29 26/31 840 840 258 950 950 30 PLA-P4 AA PLH-P4 AAH 9.7 10.6 (12.7) 1200 1380 1560 1680 33 41 30/35 32/37 840 840 298 950 950 30 PLA-P5 AA PLH-P5 AAH 12.8 14.9 (17.9) 1320 1500 1680 1800 35 43 30/35 32/37 840 840 298 950 950 30 PLA-P6 AA PLH-P6 AAH 14.3 17.1 (20.1) 1320 1500 1680 1800 37 45 32/37 34/39 840 840 298 950 950 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.81 0.81 (8.75) PUH-P3 YGAA 3.4 3.5 (5.6) 1.25 1.25 (10.83) PUH-P4 YGAA 3.7 3.9 (6.0) 1.43 1.43 (12.5) PUH-P5 YGAA 5.0 5.3 (8.3) 3000 5100 5700 1.64 1.64 (12.5) PUH-P6 YGAA 5.9 6.4 (9.4) 6000 49 82 900 350 855 50 50 3.3 10 16 51 96 900 350 1260 50 50 4.0 10 18 55 122 1050 350 1260 50 50 4.6 10 18 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.3 5.6 5.6 5.9 7.6 8.2 9.0 9.6 PLP-6 AAM PLP-6 AALM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 49 Mr. Slim Series PCA Cooling / Heating PCH Cooling / Heating Ceiling Suspended Systems ● Wired remote control with 24h-timer ● PCH units with additional electrical heating for a warm start and to increase capacity of heat pump ● Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m ● Rotary and scroll compressors ● Factory charged with R407C ● Long-life air filter ● 4 fan-stages for optimum comfort 50 ● Swing louvres with `Auto Angle´ airflow ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● High efficiency filter ● Drain pump ● Infrared remote control For detailed descriptions please view on page 70 and the following Optional PCA/PCH CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT INDOOR UNIT WITH ELECTRICAL HEATING CAPACITY (kW) Cooling Heating* 3 AIRFLOW (m /h) Low Middle 1 Middle 2 High NOISE dB(A) Low High WEIGHT PCA (kg) WEIGHT PCH (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating* OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating* 3 AIRFLOW (m /h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCH-P2 GAH PCH-P2.5 GAH PCH-P3 GAH 5.4 6.7 7.5 6.3 (7.7) 7.3 (9.4) 9.2 (11.3) 600 840 840 660 900 900 720 960 960 780 1080 1080 37 37 37 42 43 43 27 34 34 28.5 36 36 1000 1310 1310 680 680 680 210 210 210 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.43 0.55 0.55 0.43 (5.83) 0.55 (8.75) 0.55 (8.75) PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA 2.4 2.65 3.4 2.4 (3.8) 2.7 (4.8) 3.5 (5.6) 3300 3000 3000 48 48 49 71 82 82 900 900 900 350 350 350 855 855 855 40 50 50 40 50 50 2.6 3.1 3.3 10 10 10 16 16 16 PCA-P4 GA PCH-P4 GAH 9.7 10.6 (13.4) 1200 1260 1380 1500 40 45 37 39.5 1310 680 270 220-240, 1, 50 0.7 0.7 (11.25) PUH-P4 YGAA 3.6 3.8 (6.55) 5100 51 96 900 350 1260 50 50 4.0 10 18 PCA-P5 GA PCH-P5 GAH 12.4 14.9 (17.9) 1620 1800 1920 2040 41 46 43 46 1620 680 270 220-240, 1, 50 1.1 1.1 (12.5) PUH-P5 YGAA 4.9 5.1 (8.1) 5700 55 122 1050 350 1260 50 50 4.6 10 18 PCA-P6 GA PCH-P6 GAH 14.3 17.1 (20.1) 1620 1800 1920 2040 42 48 45 48 1620 680 270 220-240, 1, 50 1.1 1.1 (12.5) PUH-P6 YGAA 5.9 6.3 (9.3) 6000 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 3.7 3.8 4.5 4.3 5.3 5.6 5.5 5.8 7.6 8.1 9.0 9.6 ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 51 Mr. Slim Series PCA Cooling / Heating Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens ● The special construction enables easy cleaning of the casing and of all airflow parts ● Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) ● On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air ● 52 Rotary and scroll compressors ● Factory charged with R407C ● Wired remote control with 24h-timer ● Twin configuration possible, on page 72 ● Accessories: ● Oil mist filter (12 pcs.) PAC-SG 38 KF-E For detailed descriptions please view on page 70 and the following PCA CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT CAPACITY (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Cooling Heating Low High Low High Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) OUTDOOR UNIT POWER CONSUMPTION (kW) AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating Width Depth Height (kg) Liquid Gas Cooling Heating PCA-P3 HA 7.5 9.2 1020 1140 34 38 41 1136 650 280 PCA-P5 HA 13.0 16.0 1800 2280 44 50 56 1520 650 280 220-240, 1, 50 220-240, 1, 50 0.55 1.1 PUH-P3 YGAA PUH-P5 YGAA 3.36 3.41 3000 49 82 900 350 855 50 50 3.3 10 16 4.90 4.98 5700 55 122 1050 350 1260 50 50 4.6 10 18 380-415, 3, 50 380-415, 3, 50 5.30 5.60 7.60 8.10 * Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 53 Mr. Slim Series PKA Cooling / Heating PKH Cooling / Heating Wall Mounted Systems ● Infrared remote control with 24h-timer ● PKH units with additional electrical heating for a warm start and to increase capacity of heat pump ● Slim compact units for wall mounting ● Simple installation with easy access drain and refrigerant piping connections ● Rotary and scroll compressors ● Factory charged with R407C ● Easily removable long-life air filter 54 ● PKA/H-P1.6/2 GAL/H with 4 fan-stages ● Swing louvres with `Auto Angle´ airflow ● Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Drain pump ● Wired remote control For detailed descriptions please view on page 70 and the following Optional PKA/PKH WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT INDOOR UNIT WITH ELECTRICAL HEATING CAPACITY (kW) Cooling Heating* AIRFLOW (m3/h) Low Middle 1 Middle 2 High NOISE dB(A) Low High WEIGHT PKA (kg) WEIGHT PKH (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating* OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating* AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating PKA-P1.6 GAL PKH-P1.6 GALH 4.5 5.0 (5.8) 540 600 660 720 36 43 16 17 990 235 340 PKA-P2 GAL PKH-P2 GALH 5.4 6.3 (7.1) 540 600 660 720 36 43 16 17 990 235 340 PKA-P2.5 FAL PKH-P2.5 FALH 6.5 7.4 (9.5) 900 – – 1200 39 45 24 26 1400 235 340 PKA-P3 FAL PKH-P3 FALH 7.9 9.5 (11.6) 900 – – 1200 39 45 24 26 1400 235 340 PKA-P4 FAL PKH-P4 FALH 9.5 10.9 (13.3) 1320 – – 1680 41 46 28 30 1680 235 340 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.33 0.33 (3.3) PUH-P1.6 YGAA 1.7 1.9 (2.7) 2700 47 55 900 350 650 40 40 2.5 10 16 0.33 0.33 (3.3) PUH-P2 YGAA 2.4 2.4 (3.2) 3300 48 71 900 350 855 40 40 2.6 10 16 0.43 0.43 (8.75) PUH-P2.5 YGAA 2.7 2.6 (4.7) 3000 48 82 900 350 855 50 50 3.1 10 16 0.43 0.43 (8.75) PUH-P3 YGAA 3.4 3.6 (5.7) 3000 49 82 900 350 855 50 50 3.3 10 16 0.52 0.52 (10.0) PUH-P4 YGAA 3.6 3.8 (6.2) 5100 51 96 900 350 1260 50 50 4.0 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 2.5 2.6 3.7 3.8 4.3 4.5 5.3 5.6 5.6 5.9 ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 55 Mr. Slim Series PSA Cooling / Heating PSH Cooling / Heating Floorstanding units Function panel case integrated ● Rotary and scroll compressors and 24h-timer ● Factory charged with R407C ● PSH units with additional ● Standard long-life filter electrical heating for a warm ● Twin and triple configuration start and to increase capacity possible, on page 72 of heat pump ● Compact design and high capacity ● Simple installation with easy Accessories: access drain and refrigerant Optional parts on page 70 piping connections and the following ● 56 PSA/PSH FLOORSTANDING UNITS COOLING / HEATING INDOOR UNIT INDOOR UNIT WITH ELECTRICAL HEATING CAPACITY (kW) Cooling Heating* AIRFLOW (m3/h) Low High NOISE dB(A) Low High WEIGHT PSA (kg) WEIGHT PSH (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating* OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating* 3 AIRFLOW (m /h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating PSA-P3 GA PSH-P3 GAH 7.7 9.3 (11.4) 900 1080 40 45 43 45 600 270 1900 220-240, 1, 50 PSA-P4 GA PSH-P4 GAH 9.7 10.9 (13.6) 1440 1860 44 49 51 53 600 350 1900 220-240, 1, 50 PSA-P5 GA PSH-P5 GAH 12.4 14.6 (17.6) 1560 1980 46 51 51 53 600 350 1900 220-240, 1, 50 PSA-P6 GA PSH-P6 GAH 14.0 17.1 (20.1) 1620 2100 47 52 53 55 600 350 1900 220-240, 1, 50 0.68 0.68 (8.75) PUH-P3 YGAA 3.4 3.5 (5.6) 3000 49 82 900 350 855 50 50 3.3 10 16 1.1 1.1 (11.25) PUH-P4 YGAA 3.8 3.9 (6.6) 5100 51 96 900 350 1260 50 50 4.0 10 18 1.26 1.26 (12.5) PUH-P5 YGAA 5.0 5.4 (8.4) 5700 55 122 1050 350 1260 50 50 4.6 10 18 1.62 1.62 (12.5) PUH-P6 YGAA 5.8 6.1 (9.1) 6000 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.3 5.6 5.6 5.9 7.6 8.1 9.0 9.6 ** Values given in brackets incl. additional electrical heating ** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 57 Mr. Slim Series PEAD Cooling / Heating PEHD Cooling / Heating Above-Ceiling Concealed Ducted Systems ● Wired remote control with 24h-timer ● PEHD units with additional electrical heating for a warm start and to increase capacity of heat pump ● Simple installation with easy access drain and refrigerant piping connections ● PEAD/PEHD-P1.6/2/2.5 EA/H airflow variable - draw in from the back or underside ● Rotary and scroll compressors ● Factory charged with R407C 58 ● ● Standard long-life filter Twin, triple, quadruple configuration possible, on page 72 Accessories: ● Drain pump ● Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following PEAD/PEHD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA INDOOR UNIT W. ELECTRICAL HEATING PEHD-P1.6EAH PEHD-P2EAH PEHD-P2.5EAH PEHD-P3EAH CAPACITY (kW) Cooling 4.5 5.6 6.7 7.7 Heating* 4.9 (5.9) 6.2 (7.2) 7.2 (8.7) 9.1 (11.2) 3 AIRFLOW (m /h) Low 660 810 1020 1200 High 840 1020 1260 1500 EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) NOISE dB(A) Low 34(36) 36(38) 37(39) 37(40) High 38(43) 40(44) 41(46) 41(45) WEIGHT PEAD (kg) 33 33 42 44 WEIGHT PEHD (kg) 35 35 44 46 DIMENSIONS (mm) Width 935 935 1175 1175 Depth 700 700 700 740 Height 295 295 295 325 ELECTRICAL SUPPLY 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 (V, PHASE, Hz) RUNNING CURRENT (A) Cooling 0.55 0.63 0.7 1.7 Heating* 0.55 (4.71) 0.63 (4.8) 0.7 (7.0) 1.7 (10.4) OUTDOOR UNIT PUH-P1.6YGAA PUH-P2YGAA PUH-P2.5YGAA PUH-P3YGAA POWER Cooling 1.8 2.4 2.7 3.4 CONSUMPTION (kW) Heating* 1.8 (2.8) 2.2 (3.2) 2.5 (4.0) 3.2 (5.3) AIRFLOW (m3/h) 2700 3300 3000 3000 NOISE dB(A) 47 48 48 49 WEIGHT (kg) 55 71 82 82 DIMENSIONS (mm) Width 900 900 900 900 Depth 350 350 350 350 Height 650 855 855 855 MAX. PIPE LENGTH (m) 40 40 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 CHARGE R407C*** (kg) 2.5 2.6 3.1 3.3 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 16 16 16 ELECTRICAL SUPPLY 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 (V, PHASE, Hz) RUNNING CURRENT (A) Cooling 2.5 3.7 4.3 5.3 Heating 2.6 3.8 4.5 5.6 PEAD-P4EA PEHD-P4EAH 9.7 10.4 (12.9) 1620 2040 70(130**) 41(42) 46(48) 62 65 1415 740 325 PEAD-P5EA PEHD-P5EAH 12.3 13.9 (16.9) 2100 2520 70(130**) 44(46) 50(52) 65 68 1415 740 325 PEAD-P6EA PEHD-P6EAH 14.1 16.7 (19.7) 2190 2760 70(130**) 46(47) 51(53) 70 73 1715 740 325 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 2.6 2.6 (12.6) PUH-P4YGAA 3.9 4.0 (6.5) 5100 51 96 900 350 1260 50 50 4.0 10 18 2.7 2.7 (15.2) PUH-P5YGAA 4.9 4.8 (7.8) 5700 55 122 1050 350 1260 50 50 4.6 10 18 2.8 2.8 (15.2) PUH-P6YGAA 5.9 6.0 (9.0) 6000 57 122 1050 350 1260 50 50 4.9 10 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 5.6 5.9 7.6 8.2 9.0 9.6 *** Values given in brackets incl. additional electrical heating *** Fan motor optional on page 70 *** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 59 Mr. Slim Series PEH Cooling / Heating Concealed Ducted Systems Wired remote control with 24h-timer ● Pressure to 150 Pa ● PUH-P8/10 MYA for simultaneous operation of Mr. Slim indoor units ● Factory charged with R407C ● 60 ● Twin, triple, quadruple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following PEH CONCEALED DUCTED SYSTEMS COOLING/HEATING INDOOR UNIT CAPACITY (kW) Cooling Heating AIRFLOW (m3/h) EXTERNAL STATIC PRESSURE (Pa) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating 3 AIRFLOW (m /h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C* (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating PEH-P8 MYA 20.9 23.7 3600 50/150 53 74 1580 604 455 PEH-P10 MYA 26.0 30.5 4800 50/150 57 80 1580 604 455 380-415, 3, 50 380-415, 3, 50 1.1 1.1 PUH-P8 MYA 7.92 7.82 11100 56 215 990 840 1715 50 40 6.0 12 28 1.6 1.6 PUH-P10 MYA 9.96 9.56 11100 57 220 990 840 1715 50 40 6.5 12 28 380-415, 3, 50 380-415, 3, 50 13 12.8 16 15.4 * Factory charged, please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Rating conditions: COOLING Indoor: Outdoor: HEATING Indoor: Outdoor: 15°C - 24°C WB -15°C - 46°C DB 15°C - 27°C WB -12°C - 18°C DB 61 Mr. Slim R410A-Series Power Inverter Split and Multi-Split Systems The established Mr. Slim Series with inverter technology - efficient, economical and very quiet. 62 Advantages of Mr. Slim R410A-Series Power Inverter ● New inverter-technology and refrigerant R410A enable high energy-efficiency ● The wide range of performance allows an optimum of convenience - for a quick cooling and heating ● All outdoor units with LOW NOISE - mode, only 44 dB(A) at PUHZ-RP3VHA ● The indoor units “RP” can be connected with Mr. Slim R407C outdoor units ● Multi Split simultaneous operation ● Standard long-life filters ● Auto change over between cooling and heating mode ● A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units ● Lossnay heat exchange ventilators connectable ● Factory charged with refrigerant R410A ● Wired or infrared remote controller optional ● Remote monitoring ● Maintenance Tool for control and service ● All models can be interfaced to Building Management Systems by Lon Works Interface ● Ceiling cassette models with condensate pump ● Winter kit as standard, cooling up to -15°C. If the unit is placed in wind direction use the optional part, view page 70 and the following NEW! Rating conditions Mr. Slim Series: ● COOLING Indoor: 19°C - 35°C DB 15°C - 22.5°C WB Outdoor: -15°C - 46°C DB ● HEATING Indoor: 17°C - 28°C DB Outdoor: -11°C - 24°C DB -12°C - 18°C WB POWER INVERTERHEAT PUMP UNITS PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 PKA WALL-MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 63 63 Mr. Slim Power Inverter PLA Cooling / Heating 4-Way-In-Ceiling Cassette Systems ● Wired or infrared remote control with 24h-timer provided ● Space-saving, quadratic design ● Installation height only 258 mm (PLA-RP3 AA) ● Quiet operation noise just 28 dB(A) (PLA-RP3 AA) ● Drain pump for 850 mm height difference ● Prepared duct connections: round 150 mm, rectangular 350 x 100 mm ● 4 fan-stages for best comfort ● Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles ● Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m ● Standard long-life filter cleaning necessary every 2,500 operating hours NEW! 64 ● Simple installation with easy access drain and refrigerant piping connections ● Factory charged with R410A ● Rotary and scroll compressors ● Multi Split simultaneous operation, view page 72 Accessories: ● Space panel for installation of PLA-RP4/5/6AA into ceiling void of just 258 mm depth ● High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following POWER INVERTER PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT CAPACITY COOLING (Min. - Nominal - Max.) kW CAPACITY HEATING (Min. - Nominal - Max.) kW COP Cooling/Heating Low AIRFLOW (m3/h) Middle 1 Middle 2 High NOISE dB(A) Low High WEIGHT incl. Grille (kg) DIMENSIONS (mm) Width Indoor unit Depth Height** DIMENSIONS (mm) Width Grille Depth Height*** ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A**** PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) PLA-RP3 AA 3.3 - 7.1 - 8.1 3.5 - 8.0 - 10.2 3.60/3.42 900 960 1080 1200 28 34 24/29 840 840 258 950 950 30 220-240, 1, 50 0.79 0.79 PUHZ-RP3VHA 1.97 2.34 PLA-RP4 AA 5.0 - 10.0 - 11.4 5.6 -11.2 - 14.0 3.30/3.30 1200 1380 1560 1680 33 41 30/35 840 840 298 950 950 30 220-240, 1, 50 1.25 1.25 PUHZ-RP4VHA 3.03 3.39 PLA-RP5 AA 6.0 - 12.5 - 14.0 6.0 - 14.0 - 16.0 3.21/3.28 1320 1500 1680 1800 37 45 30/35 840 840 298 950 950 30 220-240, 1, 50 1.43 1.43 PUHZ-RP5VHA 3.89 4.27 PLA-RP6 AA 6.2 - 14.0 - 15.3 6.2 - 16.0 - 18.0 2.81/3.26 1320 1500 1680 1800 37 45 32/37 840 840 298 950 950 30 220-240, 1, 50 1.6 1.6 PUHZ-RP6VHA 4.99 4.91 3300 6000 6000 6000 44*/47 75 950 360 943 50 30 3.5 10 16 46*/49 121 900 360 1350 75 30 5.5 10 16 47*/50 121 900 360 1350 75 30 5.5 10 16 48*/50 121 900 360 1350 75 30 5.5 10 16 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 8.0 9.7 25 12.3 13.9 32 15.8 17.5 32 20.3 20.7 40 Width Depth Height (kg) Liquid Gas Cooling Heating CIRCUIT BREAKER (A) GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6AAM PLP-6AALM **** LOW NOISE mode **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 65 Mr. Slim Power Inverter PKA Cooling / Heating Wall Mounted Systems ● Infrared remote control with 24h-timer ● Slim compact units for wall mounting ● Flexible louvre for evenly spread of air ● Simple installation with easy access drain and refrigerant piping connections ● Easily removable long-life air filter ● Factory charged with R407C NEW! 66 ● ● Rotary and scroll compressors Multi Split simultaneous operation possible, page 72 Accessories: ● Drain pump ● Wired remote control For detailed descriptions please view on page 70 and the following Optional POWER INVERTER PKA WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT CAPACITY COOLING (Min. - Nominal - Max.) kW CAPACITY HEATING (Min. - Nominal - Max.) kW COP Cooling/Heating Low AIRFLOW (m3/h) High NOISE dB(A) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating AIRFLOW (m3/h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating CIRCUIT BREAKER (A) PKA-RP3FAL 3.3 - 7.1 - 8.1 3.5 - 8.0 - 10.2 3.59 / 3.33 900 1200 39 45 24 1400 235 340 220-240, 1, 50 0.43 0.43 PUHZ-RP3VHA 1.98 2.40 3300 44*/47 75 950 360 943 50 30 3.5 10 16 PKA-RP4FAL 5.0 - 10.0 - 11.4 5.6 - 11.2 - 14.0 3.41 / 3.45 1320 1680 41 46 28 1680 235 340 220-240, 1, 50 0.52 0.52 PUHZ-RP4VHA 2.93 3.25 6000 46*/49 121 950 360 1350 75 30 5.5 10 16 220-240, 1, 50 220-240, 1, 50 8.0 9.7 25 12.3 13.9 32 ** LOW NOISE mode ** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units “RP” can be connected with Mr. Slim R407C outdoor units. 67 Mr. Slim Power Inverter PEAD Cooling / Heating Above-Ceiling Concealed Ducted Systems ● Wired remote control with 24h-timer ● Standard long-life filter ● Installation height only 325 mm ● Simple installation with easy access drain and refrigerant piping connections ● Factory charged with R410A ● Rotary and scroll compressors NEW! 68 ● Multi Split simultaneous operation possible, page 72 Accessories: ● Drain pump ● Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following POWER INVERTER PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT CAPACITY COOLING (Min. - Nominal - Max.) kW CAPACITY HEATING (Min. - Nominal - Max.) kW COP Cooling/Heating Low AIRFLOW (m3/h) High EXTERNAL STATIC PRESSURE (Pa) NOISE dB(A) Low High WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating OUTDOOR UNIT POWER Cooling CONSUMPTION (kW) Heating 3 AIRFLOW (m /h) NOISE dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R410A*** (kg) PIPE SIZE Liquid ø (mm) Gas ELECTRICAL SUPPLY (V, PHASE, Hz) RUNNING CURRENT (A) Cooling Heating CIRCUIT BREAKER (A) PEAD-RP3EA 3.3 - 7.1 - 8.1 3.5 - 8.0 - 10.2 3.30/3.42 1200 1500 70(130**) 37(40) 41(45) 44 1175 740 325 220-240, 1, 50 1.6 1.6 PUHZ-RP3VHA 2.15 2.34 3300 44*/47 75 950 360 943 50 30 3.5 10 16 PEAD-RP4EA 5.0 - 10.0 - 11.2 5.6 - 11.2 - 14.0 3.25/3.22 1620 2040 70(130**) 41(42) 46(48) 62 1415 740 325 220-240, 1, 50 2.5 2.5 PUHZ-RP4VHA 3.08 3.48 6000 46*/49 121 950 360 1350 75 30 5.5 10 16 PEAD-RP5EA 6.0 - 12.5 - 14.0 6.0 - 14.0 - 16.0 3.39/3.41 2010 2520 70(130**) 44(46) 50(52) 65 1415 740 325 220-240, 1, 50 2.6 2.6 PUHZ-RP5VHA 3.69 4.11 6000 47*/50 121 950 360 1350 75 30 5.5 10 16 PEAD-RP6EA 6.2 - 14.0 - 15.3 6.2 - 16.0 - 18.0 2.85/3.36 2190 2760 70(130**) 46(47) 51(53) 70 1715 740 325 220-240, 1, 50 2.7 2.7 PUHZ-RP6VHA 4.91 4.76 6000 48*/50 121 950 360 1350 75 30 5.5 10 16 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 8.0 9.7 25 12.3 13.9 32 15.8 17.5 32 20.4 20.7 40 *** LOW NOISE mode *** Fan motor optional 130 Pa *** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 69 Mr. Slim R407C/R410A-Series Accessories Accessories Indoor / Outdoor units PART.NO. DESCRIPTION PLA/PLH PAC-SEO6 WP-E PAC-SEO1 AS-E PAC-SE21 TM-E PAC-SE13 KF-E PAC-SE60 AS-E PAC-SG03 TM-E PAC-SG01 KF-E 4-WAY-IN-CEILING CASSETTE SYSTEMS Wide panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Space panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Multi-function casement for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH High efficiency filter for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH (PAC-SE21 TM-E needed) Space panel for PLA-P 4/5/6 AA, PLH-P 4/5/6 AAH Multi-function casement for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH High efficiency filter for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH (PAC-SG03 TM-E needed) PCA/PCH PAC-SE85 DMA-E PAC-SE86 DMA-E PAC-SE80 KF-E PAC-SE81 KF-E PAC-SE82 KF-E PAC-SL99A-E CEILING SUSPENDED SYSTEMS Drain pump for PCA-P 2/2.5/3 GA, PCH-P2/2.5/3 GAH Drain pump for PCA-P 4/5/6 GA, PCH-P4/5/6 GAH High efficiency filter for PCA-P2 GA, PCH-P2 GAH High efficiency filter for PCA-P2.5/3/4 GA, PCH-P2.5/3/4 GAH High efficiency filter for PCA-P5/6 GA, PCH-P5/6 GAH Infrared remote control for PCA-P/PCH-P PCA PAC-SG38KF-E CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS Special high efficiency oil filter, 12 pieces PKA/PKH PAC-SE88 DM-E PAR-20MAAT-E WALL-MOUNTED SYSTEMS Drain pump PKA-P/PKH-P Wired remote control for PKH-P/PKA-P PEAD/PEHD PAC-KE03 DM-F PAC-SK005 MT-F PAC-SK004 MT-F PAC-SK003 MT-F CEILING CONCEALED SYSTEMS Drain pump for PEAD-P/PEHD-P Fan motor 130 Pa pressure for PEAD-P3 EA/PEHD-P3 EAH Fan motor 130 Pa pressure for PEAD-P4 EA/PEHD-P4 EAH Fan motor 130 Pa pressure for PEAD-P5/6 EA/PEHD-P5/6 EAH PU/PUH PAC-SF37 DS-E PAC-SF08 SG-E PAC-SF16 DP-E PAC-SF17 DP-E PAC-SF09 AG OUTDOOR UNITS Drain socket for Mr. Slim outdoor units P1.6 – P6 Air outlet guide for Mr. Slim outdoor units P1.6 – P6 (for P4/5/6 2x PAC-SF08 SG-E) Drain pan PU(H)-P 1.6/4 Drain pan PU(H)-P 5/6 Airflow panel for cooling to -15° C for P1.6 – P6 (for P4/5/6 2x PAC-SF09 AG) PUHZ PAC-SG61DS-E PAC-SG59SG-E PAC-SG64DP-E OUTDOOR UNITS Drain socket for Mr. Slim Power Inverter outdoor units RP3-RP6 Air outlet guide for outdoor units RP3-RP6. RP4/5/6 require two PAC-SG59SG-E Drain pan for PUHZ-RP3/4/5/6 VHA 70 Mr. Slim R407C/R410A-Series Accessories Control Accessories PART.NO. PAC-SE41 TS-E PAC-SF48 MA-E PAC-SF40 RM-E PAC-SE55 RA-E CMS-MNF-B LMAP02-E PAC-YT32PTA PAC-SF50MA PAC-SC50KUA PAC-SK52ST DESCRIPTION External Temperature Sensor A/M Net-Converter Operation remote controller board Remote on/off Maintenance Tool, to use with PAC-SF48 MA-E and PAC-SC34 KUA LonWorks®-Interface, to use with PAC-SF48 MA-E and PAC-SC50 KUA LCD weekly set back program timer – operation only with wired remote control models A/M Net-Converter for Mr. Slim Inverter PUHZ R410 A Power Supply Service-Display for outdoor units P1-P6 and RP3/4/5/6 Further information: Planning handbook Mr. Slim Series 71 Accessories for Multi Split Systems*/Distributors: ● Twin, triple, quadruple configuration of Mr. Slim indoor units with single outdoor units possible. ● Ideally suited to open plan areas in small- to medium-sized offices or shops. Mr. Slim R407C: Combinations: INDOOR UNITS OUTDOOR UNITS COMIBINATION PU(H)-P3 YGAA PU(H)-P4 YGAA PU(H)-P5 YGAA PU(H)-P6 YGAA PUH-P8 MYA PUH-P10 MYA DISTRIBUTOR PLA-P/PLH-P1.6/2/2.5/3/4/5 PSA-P/PSH-P3/4/5 PCA-P/PCH-P2/2.5/3/4/5 PEAD-P/PEHD-P1.6/2/2.5/3/4/5 PKA-P/PKH-P1.6/2/2.5/3/4 PMH-P1.6/2 Twin 50:50 1.6 + 1.6 2+2 2.5 +2.5 3+3 – – SDD-50 DA-E Twin 50:50 4+4 5+5 SDD-50WSA-E Triple 33:33:33 – – – 2+2+2 2.5 + 2.5 + 2.5 3+3+3 SDT-111 SA-E Triple 25:25:50 – – – 1.6 + 1.6 + 3 2+2+4 2.5 + 2.5 + 5 SDT-112 SA-E Triple 20:40:40 Quadruple 25:25:25:25 1.6 + 3 + 3 2+4+4 SDT-122 SA-E 2+2+2+2 2.5 + 2.5 + 2.5 + 2.5 SDT-1111 SA-E Mr. Slim R410A: Combinations: INDOOR UNITS** OUTDOOR UNITS COMBINATION PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA DISTRIBUTOR 72 PLA-RP1.6/2/2.5/3 PKA-RP1.6/2/2.5/3 PEAD-RP1.6/2/2.5/3 Twin 50:50 1.6 + 1.6** 2 + 2** 2.5 +2.5** 3+3 SDD-50SR-E Triple 33:33:33 – – – 2 + 2 + 2** SDT-111R-E ** Attention: Only indoor units of same type can be installed. In Multi-Split-Mode all indoor units have to be installed in the same room because of temperature sense in the master unit. ** RP1.6/2/2.5 available from August 2004 Mr. Slim-Series Technical Data Refrigerants R407C/R410A Charge R407C CHARGING (ONE WAY) IN kg 20 m 30 m 40 m 1.7 1.8 – 2.5 2.6 3.0 2.6 3.1 3.7 3.1 3.3 3.9 3.3 – 3.9 4.0 – 4.7 4.6 – 5.3 4.9 – 5.6 7.5 8.0 8.5 8.0 8.5 9.0 OUTDOOR UNITS 10 m 1.7 2.5 2.6 3.1 – – – – 7.0 7.5 ● 50 m PUH-P1 VGAA – Charge concerning single operation, PU(H)-P1.6 YGAA – optional charges for simultaneous PU(H)-P2 YGAA – operation as in the planning guide PU(H)-P2.5 YGAA 4.5 PU(H)-P3 YGAA 4.5 described. PU(H)-P4 YGAA 5.4 ● Outdoor units P1-2.5: Factory charged PU(H)-P5 YGAA 6.0 to 20 m pipe length PU(H)-P6 YGAA 6.3 PUH-P8 MYA 9.0 ● Outdoor units P3-P6: Factory charged PUH-P10 MYA 9.5 to 30 m pipe length ● Outdoor units P8 and P10: Factory charged 6 kg and 6.5 kg R407C. Please view in the table above pipe length and charging data Correction Factor R407C EFFICIENCY CLASS CORRECTION FACTOR CAPACITY OF COOLING/HEATING PIPE LENGTH (ONE WAY)/M 5 10 15 20 25 30 35 40 45 50 –/– –/– –/– –/– 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 –/– –/– 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 –/– –/– P1 1.00/1.00 0.992/0.997 0.983/0.996 0.978/0.994 0.966/0.991 0.959/0.989 P1.6 P2 P2.5 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978 P3 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P4 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978 P5 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P6 1.00/1.00 0.975/0.998 0.955/0.995 0.935/0.993 0.918/0.990 0.900/0.988 0.884/0.985 0.869/0.983 0.855/0.980 0.840/0.978 P8 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.965/0.995 0.960/0.995 0.940/0.995 0.935/0.995 0.930/0.995 P10 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.960/0.995 0.958/0.995 0.955/0.995 0.950/0.995 0.950/0.995 Charge R410A ● Outdoor units PUHZ-P3/4/5/6VHA factory charged to 30 m pipe length (one-way), optional charges as in the table. OUTDOOR UNITS PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA 10 m 3.1 5.1 5.1 5.1 CHARGING (ONE WAY) IN kg 30 m 40 m 50 m 3.5 4.1 4.7 5.5 6.1 6.7 5.5 6.1 6.7 5.5 6.1 6.7 20 m 3.3 5.3 5.3 5.3 60 m – 7.3 7.3 7.3 75 m – 7.9 7.9 7.9 Correction Factor R410A EFFICIENCY CLASS PIPE LENGTH (ONE WAY)/M CORRECTION FACTOR CAPACITY OF COOLING/HEATING 5 10 15 20 30 40 50 60 70 75 –/– –/– –/– RP3 1.00/1.00 0.989/0.997 0.978/0.994 0.967/0.991 0.947/0.985 0.930/0.979 0.905/0.973 RP4 1.00/1.00 0.985/0.997 0.971/0.994 0.958/0.991 0.931/0.985 0.908/0.979 0.887/0.973 0.865/0.967 0.847/0.961 0.838/0.958 RP5 1.00/1.00 0.982/0.997 0.963/0.994 0.9470.991 0.914/0.985 0.885/0.979 0.858/0.973 0.834/0.967 0.812/0.961 0.802/0.958 RP6 1.00/1.00 0.976/0.997 0.953/0.994 0.932/0.991 0.893/0.985 0.858/0.979 0.828/0.973 0.800/0.967 0.776/0.961 0.764/0.958 73 City Multi-Series Y and R2 For large applications such as office blocks, hotels and large retail stores, City Multi – variable refrigerant flow (VRF) multi-split systems – offer significant advantages over centralised plant systems. A certain times of the year, many buildings can require cooling in some areas and heating in others – even in adjacent rooms. The outstanding City Multi R2 and WR2 systems meet this requirement by distributing surplus heat from cooling operations to rooms where it is needed. This can result in energy savings of up to 20% over conventional systems. The water-cooled WR-system is adaptable specially to high-rise buildings. 74 Advantages of the City Multi-Series ● City Multi Super Y-Series manages up to 32 indoor units in a single refrigerant circle ● Simultaneous cooling and heating with incomparable 2-pipe-system ● By distributing surplus heat from cooling operations to rooms where it is needed, the result can be 15% - 20% energy savings over conventional systems ● Automatic switch of operating mode (heating/cooling), the room temperature stays constant ● Many indoor units, capacity-steps and installation possibilities to select ● Inverter-driven outdoor compressor units with very low start currents ● Remote control of individual indoor units, to centralised systems, right up to full interface with industry standard Building Management Systems CITY MULTI Y-Series City Multi Y-Series utilise 2-pipe technology for cooling and heating mode. By manual switch the most comfortable air conditions can be choosen. The system is very versatile, it is possible to install up to 32 different indoor units to a single refrigerant circle. The capacity of all installed indoor units can be 50% up to 130%. CITY MULTI R2-Series The City Multi range has been re-engineered to use R407C ozone-friendly refrigerant – without performance loss. Modern buildings with a reduced exchange of air, technical equipment like PCs, printer etc. which warm up the air require efficient air conditioning with simultaneous cooling and heating. The "Fuzzy-logic” makes individual air conditioning with max. 24 indoor units possible. Inverter-driven outdoor compressor units with very low start currents save energy. Distributing surplus heat from cooling operations to rooms where it is needed is another way to save energy. Operating range of City Multi ● Cooling: indoor 15° – 24°C (WB)/outdoor -5° – 43°C (DB) (water temperature for WR2: 10°C – 45°C) ● Heating (Y-Series): indoor 15° – 27°C (DB)/ outdoor -15° – 15.5°C (WB) ● Heating (R2-Series): indoor 15° – 27°C (DB)/ outdoor -15° – 15.5°C (WB) (water temperature for WR2: 10°C – 45°C) Control options to suit every kind of application City Multi systems offer an extremely wide choice of control solutions, from remote control of individual indoor units, to centralised systems and computer-aided systems which allow to control up to 2,000 units. Right up to full interface with industry standard Building Management Systems. Features of City Multi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 City Multi Y-series - Outdoors units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 City Multi R2 series - Outdoors units and BC-controllers . . . . . . . . . . . . . . . . . . . . . . 82 PMFY/PLFY - Ceiling cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 PCFY/PKFY - Suspended indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 PEFY - Concealed ducted indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 PFFY - Floor standing indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 City Multi - Control accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 City Multi - Accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 75 City Multi Systems: Economic, efficient and high-quality CITY MULTI Y-SERIES Switching between Heating and Cooling Flexible and Powerful Response from Compact Dimensions Flexibility is the motto with the City Multi Y-Series. A wide line-up of indoor units in combination with a flexible piping system can conform to any layout. From 8 to 32 indoor units, depending on capacity, can be connected to Y-Standard, BIG Y and SUPER Y outdoor units. All indoor units connected to only one refrigerant circuit. This enables easy air conditioning of areas requiring individual control. In common with the R2, the City Multi Y-Series can be easily operated through a central controller. Header Branch Indoor unit Y-Series Outdoor unit Indoor unit 76 CITY MULTI R2-SERIES Simultaneous Cooling and Heating excellent air conditioning under the aspect of economy. The R2-System means that simultaneous cooling and heating is possible. With the BC Controller connecting from 4 to 24 indoor units to one outdoor unit using only two pipes and energy-saving heat recovery operation, economy and efficiency are guaranteed. Smooth auto-switching (heating/cooling) based on set temperature realises easier operation and more comfortable environment in auto-mode. The WR2-System uses the same technical bases like the well-known R2-System. But the WR2-Series is the world´s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. WR2-System is specially for high-rise buildings. R2-Series Outdoor unit WR2-Series Outdoor unit Conference room (cooling) Water piping Connection Office (cooling) BC Controller Two-Pipe system OA room (cooling) Conference room (heating) Office (heating) World-wide the only system for simultaneous cooling and heating with 2 pipes. 77 Mitsubishi Electric FEATURES of CITY MULTI Flexible and Adaptable The variety provided by 19 outdoor models and 65 indoor models (9 different types) increase design flexibility. The Y-Series: Cooling or heating mode, a maximum of 32 indoor units connectable with one refrigerant circuit. The R2-Series: Simultaneous heating/cooling with up to 24 indoor units and heat recovery by BC-controller. R407C WR2-Series: World´s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. SERIES Outdoor unit Cooling capacity (kW) Heating capacity (kW) No. of Connect indoor units Total capacity indoor units Capacity of connectable indoor models* Y-SERIES PUMY-P125 YMA PUY-P200 YEM-A PUY-P250 YEM-A PUY-P315 YEM-A PUHY-P200 YEM-A PUHY-P250 YEM-A PUHY-P315 YEM-A 14.0 22.4 28.0 35.5 22.4 28.0 35.5 16,0 – – – 25.0 31.5 40,0 1-8 1-13 1-16 1-16 1-13 1-16 1-16 50 - 130% 20 - 125 50 - 130 % 20 - 250 BIG YSERIES PUHY-P400 YMF-C PUHY-P500 YMF-C 45.0 56.0 50.0 63.0 1-20 1-20 50 - 130% 25 - 250 SUPER YSERIES PUHY-P400 YMF-C + PUHN-P200 YMF-C PUHY-P400 YMF-C + PUHN-P250 YMF-C PUHY-P500 YMF-C + PUHN-P200 YMF-C PUHY-P500 YMF-C + PUHN-P250 YMF-C 67.4 73.0 78.4 84.0 75.0 81.5 88.0 94.5 2-32 2-32 2-32 2-32 50 - 130% 20 - 250 R2-SERIES PURY-P200 YEM-A PURY-P250 YEM-A 22.4 28.0 25.0 31.5 1-15 1-16 50 - 150% 20 - 250 BIG R2SERIES PURY-P400 YMF-C PURY-P500 YMF-C 45.0 56.0 50.0 63.0 2-24 2-24 50 - 150% 20 - 250 WR2SERIES PQRY-P200 YMF-C PQRY-P250 YMF-C 22.4 28.0 25.0 31.5 1-15 1-16 50 - 150% 20 - 250 * Indoor units available: Type 20 (2.2 kW) up to type 250 (28.0 kW) 78 Indoor units - Overview Capacity Type All City Multi indoor units are compatible to Y-Series, R2- and WR2-Series. Capacity code P 20 P 25 P 32 P 40 P 50 P 63 P 71 P 80 P 100 P 125 P 140 P 200 P 250 Cooling capacity (kW) 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0 Heating capacity (kW) 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5 Ceiling Cassette Type (1-way airflow) PMFY-VBM-A ● ● ● ● Ceiling Cassette Type (2-way airflow) PLFY-VLMD-A/-B ● ● ● ● ● ● ● ● ● B-model A-model Ceiling Cassette Type (4-way airflow) ● ● ● ● PLFY-VKM-A/VAM-A ● ● ● Ceiling Concealed (horizontal airflow) PEFY-VML-A/VMH-A ● ● ● ● ● ● ● ● ● ● ● ● ● H-model* L-model* Ceiling Concealed (variable airflow) PEFY-VMM-A ● ● ● ● ● ● ● ● ● ● ● Ceiling Suspended Type ● PCFY-VGM-A ● ● ● Wall Mounted Type PKFY-VAM-A ● ● Wall Mounted Type PKFY-VGM-A ● ● ● Floor Standing Exposed Type PFFY-VLEM-A Floor Standing Concealed Type PFFY-VLRM-A ● ● ● ● ● ● ● ● ● ● ● ● * L-model: low stat. pressure, H-model: high stat. pressure 79 Outdoor units - Technical data City Multi Y-Series, Cooling or Heating OUTDOOR UNIT PUMY-P125 YMA MODEL REFERENCE PUMY-P125 YMA CAPACITY (kW) 14.0 16.0 5400 54 127 1020 350 1280 100 30 8.5 10 18 380-415V, 50Hz, 3 5.95 5.58 8 9.1 1-8 / 20-125 Cooling Heating AIRFLOW (m3/h) NOISE* dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height* MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C*** (kg) PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) INDOOR UNITS TO INSTALL (pcs.) City Multi Y-Series: PUMY-P125 YMA City Multi Standard Y: PU(H)Y-P 200/250/315 YEM-A STANDARD Y OUTDOOR UNIT MODEL REFERENCE CAPACITY (kW) Cooling Heating AIRFLOW (m3/h) NOISE* dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height* MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) INDOOR UNITS TO INSTALL (Number/Type) COOLING ONLY COOLING/HEATING PUYP200YEM-A PUYP250YEM-A PUYP315YEM-A PUHYP200YEM-A 22.4 – 12000 56 225 990 840 1755 240 50 7 12 28 380-415V, 50Hz, 3 6.32 – 8 10.6 1-13/20-250 28.0 – 12000 57 225 990 840 1755 240 50 7 12 28 35.5 – 12000 60 240 990 840 1755 240 50 9 12 35 380-415V, 50Hz, 3 12.3 – 8 20.3 1-16/20-250 22.4 25.0 12000 56 225 990 840 1755 240 50 7 12 28 8.54 – 8 14.4 1-16/20-250 *** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. *** one-way *** Factory charged to 50 m pipe length (one-way) 80 6.32 6.80 8 11.4 1-13/20-250 PUHYP250YEM-A 28.0 31.5 12000 57 225 990 840 1755 240 50 7 12 28 380-415V, 50Hz, 3 8.54 8.95 8 15.1 1-16/20-250 PUHYP315YEM-A 35.5 40.0 12000 60 240 990 840 1755 240 50 9 12 35 12.3 12.49 8 20.6 1-16/20-250 City Multi BIG Y and Super Y-Series BIG Y OUTDOOR UNITS MODEL REFERENCE CAPACITY (kW) AIRFLOW NOISE* WEIGHT DIMENSIONS (mm) MAX. PIPE LENGTH** MAX. HEIGHT DIFFERENCE CHARGE R407C PIPE SIZE ø (mm) Cooling Heating (m3/h) dB(A) (kg) Width Depth Height (m) (m) (kg) liquid gas ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating INDOOR UNITS TO INSTALL (pcs.) PUHY-P400YMF-C PUHY-P500YMF-C 45.0 56.0 50.0 63.0 22200 22200 60 60 440 475 1990 1990 840 840 1715 1715 220 220 50 50 16 22 16 16 35 35 380-415V, 50Hz, 3 16.3 20.5 15.2 19.0 1-20/25-250 City Multi Big Y: PUHY-P400/500 YMF-C PUHN UNITS MODEL REFERENCE CAPACITY (kW) AIRFLOW NOISE* WEIGHT DIMENSIONS (mm) MAX. PIPE LENGTH** MAX. HEIGHT DIFFERENCE CHARGE R407C PIPE SIZE ø (mm) Cooling Heating (m3/h) dB(A) (kg) Width Depth Height (m) (m) (kg) liquid gas ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating PUHN-P200YMF-C PUHN-P250YMF-C 22.4 28.0 25.0 31.5 11100 11100 61 62 240 255 990 990 840 840 1715 1715 220 220 50 50 6.5 8.5 12 12 28 28 380-415V, 50Hz, 3 Depending of Combination City Multi Super Y SUPER Y: COMBINATION OF BIG Y AND PUHN MODEL REFERENCE Super Y PUHY-P400YMF-C + PUHN-P200YMF-C Super Y PUHY-P400YMF-C + PUHN-P250YMF-C Super Y PUHY-P500YMF-C + PUHN-P200YMF-C Super Y PUHY-P500YMF-C + PUHN-P250YMF-C Cooling capacity (kW) Heating capacity (kW) 67.4 73.0 78.4 84.0 75.0 81.5 88.0 94.5 Noise level dB(A) 61.5 62.0 61.5 62.0 Indoor units to install (pcs.) 2-32/20-250 2-32/20-250 2-32/20-250 2-32/20-250 When adding 20 or more indoor units to one system transmission booster PAC-SF46EPA is needed. For connecting PUHN use SUPER Y Kit CMC-30A. ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way 81 Outdoor units - Technical data City Multi R2-Series Cooling + Heating simultaneous with heat recovery City Multi R2: PURY-P 200/250 YEM-A R2-OUTDOOR UNITS MODEL REFERENCE CAPACITY (kW) Cooling Heating AIRFLOW (m3/h) NOISE* dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height MAX. PIPE LENGTH** (m) MAX. HEIGHT DIFFERENCE (m) CHARGE R407C (kg) PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) INDOOR UNITS TO INSTALL (pcs.) PURYP200YEM-A PURYP250YEM-A 22.4 25.0 12000 56 238 990 840 1755 240 50 10.5 18 28 380-415V, 50Hz, 3 6.32 6.80 8 11.4 1-15/20-250 28.0 31.5 12000 57 238 990 840 1755 240 50 10.5 18 28 380-415V, 50Hz, 3 8.54 8.95 8 15.1 1-16/20-250 WR2-SERIES WITH WATER COOLED HEAT EXCHANGER (ONLY FOR INDOOR USE) MODEL REFERENCE PQRY-P200YMF-C CAPACITY (kW) City Multi WR2: PQRY-P200/250 YMF-C Note: 1) Cooling/heating capacity indicates the maximum value at operation under the following conditions: Cooling/outdoor: 35°C DB/24°C WB Watertemperature WR2 30°C Heating/outdoor: 7°C DB/6°C WB Watertemperature WR2 20°C 2) The ambient temperature of heat source units has to be kept below 40°C DB. The ambient relative humidity of heat source units has to be kept below 80% COOLING WATER FLOW RATE PRESSURE DROP MAX. PIPING LENGTH** REFRIGERANT CIRCUIT MAX. HIGH DIFFERENCE REFRIGERANT CIRCUIT CHARGE R407C NOISE* WEIGHT DIMENSIONS (mm) Cooling Heating (m3/h) (k Pa) (m) (m) (kg) dB(A) (kg) Width Depth Height ELECTRICAL SUPPLY (V, PHASE, Hz) INPUT POWER (kW) Cooling Heating STARTING CURRENT (A) RUNNING CURRENT (A) PIPE SIZE ø (mm) liquid GAS OPERATING TEMP. RANGE COOLING INDOOR HEATING INDOOR INDOOR UNITS NO./TYPE PQRY-P250YMF-C 22.4 25.0 3.9 8 220 28.0 31.5 4.9 10 220 50 50 7.5 51 270 1150 500 1670 8.5 52 280 1150 500 1670 380-415V, 50Hz, 3 7.6 9.7 7.4 9.4 12 12 12.1 15.5 18 18 28 28 15ºC – 24ºC (WB) / watertemp.10º C – 45º C 15ºC – 27ºC (DB) / watertemp.10º C – 45º C 1-15/20-250 1-16/20-250 BC-CONTROLLER FOR R2/WR2-SERIES liquid gas CMBP104V-F 4 18 28 CMBP105V-F 5 18 28 CMBP106V-F 6 18 28 CMBP108V-F 8 18 28 CMBP1010V-F 10 18 28 CMBP1013V-F 13 18 28 CMBP1016V-F 16 18 28 liquid gas 10 16 10 16 10 16 10 16 10 16 10 16 10 16 24 648 432 284 27 648 432 284 39 648 432 284 47 1098 432 284 54 1098 432 284 0.07 0.3 0.08 0.36 0.16 0.69 0.2 0.89 0.25 1.08 MODEL REFERENCE BC-Controller – required for R2/WR2 ** Noise level measured at a position of 1m in front of the unit. ** one-way NUMBER OF CONNECTIONS PIPE SIZE EXT., ø (mm) BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) Indoor unit at BC-Controller WEIGHT DIMENSIONS (mm) (kg) Width Depth Height ELECTRICAL SUPPLY, (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) 82 29 34 648 648 432 432 284 284 220-240V, 50Hz, 1 0.09 0.13 0.43 0.56 BIG R2-OUTDOOR UNITS MODEL REFERENCE CAPACITY (kW) PURY-P400YMF-C PURY-P500YMF-C 45,0 56,0 50.0 63,0 22200 22200 60 60 470 500 1990 1990 840 840 1715 1715 250 250 50 50 20 22 28 28 35 35 380-415V, 50Hz, 3 16,3 20.5 15.2 19.0 2-24/20-250 Cooling Heating (m3/h) dB(A) (kg) Width Depth Height (m) (m) (kg) liquid gas AIRFLOW NOISE* WEIGHT DIMENSIONS (mm) MAX PIPE LENGTH** MAX HIGH DIFFERENCE CHARGE R407C PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (Cooling) (Heating) INDOOR UNITS TO INSTALL No./Type City Multi Big R2: PURY-P400/500 YMF-C ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way MASTER-CONTROLLER FOR BIG R2-SERIES liquid gas CMBP108V-FA 8 28 35 CMBP1010V-FA 10 28 35 CMBP1013V-FA 13 28 35 CMBP1016V-FA 16 28 35 liquid gas 10 16 10 16 10 16 10 16 MODEL REFERENCE NUMBER OF CONNECTIONS PIPE SIZE EXT., ø (mm) BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) Indoor unit at BC-Controller PIPE SIZE EXT. ø (mm) liquid gas Master-Controller at Slave-Controller WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY, (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) 12 18 28 44 1110 520 289 0.14 0.58 12 12 18 18 28 28 49 57 1110 1110 520 520 289 289 220-240V, 50Hz, 1 0.17 0.23 0.7 0.89 SLAVE-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE NUMBER OF CONNECTIONS PIPE SIZE EXT., ø (mm) liquid gas Slave Controller at Master Controller PIPE SIZE EXT. ø (mm) liquid gas Indoor unit at Slave Controller WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY, (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) CMBP108V-FB 8 12 18 28 10 16 12 18 28 64 1110 520 289 MasterController 0.26 1.08 Note: The Slave BC-Controller can only use in combination with the Master Controller SlaveController 32 648 432 284 220-240V, 50Hz, 1 0.128 0.53 83 Indoor Units - Technical Data PMFY 1-WAY IN-CEILING CASSETTES MODEL REFERENCE GRILLE MODEL CAPACITY (kW) Cooling Heating Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height** liquid gas AIRFLOW (m3/h) NOISE* (Low/High) WEIGHT / incl. Grille DIMENSIONS (mm) (Grille) PIPE SIZE ø (mm) ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER RUNNING CURRENT PMFY-P20VBM-A PMP-40 BM 2.2 2.5 390 432 480 522 27/35 14 (17) 854 (1000) 395 (470) 230 (30) 6 12 (kW) (A) 0.042 0.2 PMFY-P25VBM-A PMFY-P32VBM-A PMP-40 BM PMP-40 BM 2.8 3.6 3.2 4.0 438 438 480 480 512 512 558 558 32/37 32/37 14 (17) 14 (17) 854 (1000) 854 (1000) 395 (470) 395 (470) 230 (30) 230 (30) 6 6 12 12 220 – 240 V, 50 Hz, 1 0.044 0.044 0.21 0.21 PMFY-P40VBM-A PMP-40 BM 4.5 5.0 462 522 582 642 33/39 14 (17) 854 (1000) 395 (470) 230 (30) 6 12 0.054 0.26 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 2-WAY IN-CEILING CASSETTES PLFYPLFYPLFYP20VLMD-B P25VLMD-B P32VLMD-B CMP-40 CMP-40 CMP-40 VLW-B VLW-B VLW-B MODEL REFERENCE GRILLE MODEL CAPACITY (kW) AIRFLOW (m3/h) NOISE* (Low/High) Cooling Heating Low Middle 1 Middle 2 High dB(A) 2.2 2.5 390 480 – 570 27 / 33 WEIGHT / incl. Grille DIMENSIONS (mm) (Grille) (kg) 23 (29.5) Width 776 (1080) Depth 634 (710) Height** 338 (20) PIPE SIZE ø (mm) liquid 6 gas 12 ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) 0.075 RUNNING CURRENT (A) 0.37 2.8 3.2 390 480 – 570 27 / 33 3.6 4.0 390 480 – 570 27 / 33 23 (29.5) 24 (30.5) 776 (1080) 776 (1080) 634 (710) 634 (710) 338 (20) 338 (20) 6 6 12 12 0.075 0.37 0.075 0.37 PLFYPLFYPLFYPLFYPLFYPLFYP40VLMD-B P50VLMD-B P63VLMD-B P80VLMD-A P100VLMD-A P125VLMD-A CMP-40 CMP-63 CMP-63 CMP-63 CMP-125 CMP-125 VLW-B VLW-B VLW-B LW-F LW-F LW-F 4.5 5.0 420 510 – 630 29 / 36 5.6 6.3 540 660 – 750 31 / 37 24 (30.5) 27 (34.5) 776 (1080) 946 (1250) 634 (710) 634 (710) 338 (20) 338 (20) 6 6 12 12 220-240V, 50Hz, 1 0.085 0.086 0.42 0.43 7.1 8.0 600 780 – 930 32 / 39 28 (35.5) 946 (1250) 634 (710) 338 (20) 10 16 9.0 10.0 900 1020 1140 1260 36 / 43 11.2 12.5 1260 1380 1560 1740 37 / 43 14.0 16.0 1440 1620 1800 1980 40 / 46 41 (51) 56 (67.5) 56 (67.5) 1358 (1650) 1708 (2000) 1708 (2000) 606 (670) 606 (670) 606 (670) 338 (8) 338 (8) 338 (8) 10 10 10 16 18 18 0.105 0.51 0.23 1.1 0.25 1.2 0.28 1.35 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 4-WAY IN-CEILING CASSETTES MODEL REFERENCE GRILLE MODEL CAPACITY (kW) AIRFLOW (m3/h) NOISE* (Low/High) WEIGHT / incl. Grille DIMENSIONS (Grille) Cooling Heating Low Middle 1 Middle 2 High dB(A) PLFYP32VKM-A PLP-2.5KC PLFYP40VKM-A PLP-2.5KC PLFYP50VKM-A PLP-2.5KC PLFYP63VKM-A PLP-2.5KC PLFYP80VAM-A PLP-6AA PLFYP100VAM-A PLP-6AA PLFYP125VAM-A PLP-6AA 3.6 4.0 780 840 870 900 31 / 35 4.5 5.0 780 840 870 900 31 / 35 5.6 6.3 780 840 900 960 32 / 37 7.1 8.0 840 900 960 1020 35 / 39 9.0 10.0 960 1080 1200 1320 30 / 37 11.2 12.5 1200 1380 1560 1680 33 / 41 14.0 16.0 1320 1500 1680 1800 35 / 43 19 (22.7) 660 (760) 660 (760) 298 (30) 6 12 19 (22.7) 660 (760) 660 (760) 298 (30) 6 16 24 (29) 840 (950) 840 (950) 258 (30) 10 16 30 (35) 840 (950) 840 (950) 298 (30) 10 18 30 (35) 840 (950) 840 (950) 298 (30) 10 18 0.13 0.6 0.14 0.64 0.18 0.86 0.3 1.43 0.34 1.64 (kg) 19 (22.7) Width 660 (760) Depth 660 (760) Height** 298 (30) PIPE SIZE ø (mm) liquid 6 gas 12 ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) 0.13 RUNNING CURRENT (A) 0.6 20 (23.7) 660 (760) 660 (760) 298 (30) 10 16 220-240V, 50Hz,1 0.15 0.68 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 84 PCFY SUSPENDED INDOOR UNITS MODEL REFERENCE CAPACITY (kW) AIRFLOW (m3/h) NOISE* (Low/High) WEIGHT DIMENSIONS (mm) PIPE SIZE ø (mm) ELECTRICAL SUPPLY INPUT POWER RUNNING CURRENT Cooling Heating Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Hight liquid gas (V, Freq.,Phase) (kW) (A) PCFYP40VGM-A PCFYP63VGM-A PCFYP100VGM-A PCFYP125VGM-A 4.5 5.0 480 600 660 720 29 / 38 7.1 8.0 720 840 960 1080 32 / 39 11.2 12.5 1080 1200 1380 1500 36 / 43 14.0 16.0 1560 1680 1920 2100 37 / 44 27 1000 680 210 6 12 34 1310 680 210 10 16 0.10 0.46 0.13 0.6 37 1310 680 270 10 18 220-240V, 50Hz, 1 0.16 0.73 43 1620 680 270 10 18 0.24 1.1 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber PKFY WALL MOUNTED INDOOR UNITS MODEL REFERENCE CAPACITY (kW) AIRFLOW (m3/h) NOISE* (Low/High) WEIGHT DIMENSIONS (mm) PKFY-P20VAM-A Cooling Heating Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) PKFY-P25VAM-A PKFY-P32VGM-A PKFY-P40VGM-A PKFY-P50VGM-A 2.2 2.5 294 312 336 354 32 / 36 2.8 3.2 294 312 336 354 32 / 36 3.6 4.0 480 570 630 690 33 / 41 4.5 5.0 480 570 630 690 33 / 41 5.6 6.3 540 600 660 720 34 / 43 8.5 815 158 295 6 12 8.5 815 158 295 6 12 16 990 235 340 6 12 16 990 235 340 10 16 0.04 0.2 0.04 0.2 16 990 235 340 6 12 220-240V, 50Hz, 1 0.07 0.32 0.07 0.32 0.07 0.32 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber 85 Indoor Units - Technical Data PEFY CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, VML WITH FILTER AS STANDARD PEFYP20VML-A MODEL REFERENCE CAPACITY (kW) Cooling Heating AIRFLOW (m3/h) Low Middle High EXT. STATIC PRESSURE (Pa) NOISE* (Low/High) dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) PEFYP25VML-A PEFYP32VML-A PEFYP40VMH-A 2.2 2.5 324 390 474 5 29/36 18 720 550 225 6 12 2.8 3.2 324 390 474 5 29/36 18 720 550 225 6 12 3.6 4.0 360 450 570 5 30/40 18 720 550 225 6 12 4.5 5.0 600 – 840 0.05 0.24 0.05 0.24 0.07 0.32 PEFYP50VMH-A 27/34 44 750 900 380 6 12 220-240V, 50Hz, 1 0.19 0.88 PEFYP63VMH-A PEFYP71 VMH-A 5.6 7.1 6.3 8.0 600 810 – – 840 1140 50 / 100 /150 / 200 27/34 32/38 44 45 750 750 900 900 380 380 10 10 16 16 8.0 9.0 930 – 1320 32/39 50 1000 900 380 10 16 0.19 0.88 0.26 1.20 0.24 1.12 PEFY CEILING CONCEALED DUCTED (REAR SUCTION) INDOOR UNITS PEFYP80VMH-A MODEL REFERENCE CAPACITY (kW) Cooling Heating AIRFLOW (Low/High) (m3/h) EXT. STATIC PRESSURE (Pa) NOISE* WEIGHT DIMENSIONS (mm) (Low/High) dB(A) (kg) Width Depth Hight PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) (kW) RUNNING CURRENT (A) PEFYP100VMH-A 9.0 10.0 1080/1500 11.2 12.5 1590/2280 35/41 50 1000 900 380 10 16 34/42 70 1200 900 380 10 18 0.32 1.47 0.48 2.34 PEFYP125VMH-A PEFYP140VMH-A** 14.0 16.0 1590/2280 16.0 18.0 1680/2400 PEFYP200VMH-A** PEFYP250 VMH-A** 22.4 25.0 3480 50/100/150/200 28.0 31.5 4320 100/130/220/260 34/42 70 1200 900 380 10 18 220-240V, 50Hz, 1 0.48 2.34 34/42 70 1200 900 380 10 18 45*** 52*** 100 100 1250 1250 1120 1120 470 470 12 12 28 28 380-415V, 50Hz, 3 0.99 1.23 1.62 2.00 0.48 2.35 ***The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Refering to projects. Please ask for delivery times. *** at 220 PA PEFY CEILING CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, FILTER AS STANDARD PEFYPEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY PEFY P20VMM-A P25VMM-A P32VMM-A P40VMM-A P50VMM-A P63VMM-A P71VMM-A P80VMM-A P100VMM-A P125VMM-A P140VMM-A MODEL REFERENCE CAPACITY (kW) Heizleistung AIRFLOW(m3/h) Cooling Heating Low Middle High EXT. STATIC PRESSURE (Pa) NOISE* (Low/High) dB(A) WEIGHT (kg) DIMENSIONS (mm) Width Depth Hight PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) 2.2 2.5 360 432 510 30/50/100 27 / 32 27 815 700 295 6 12 2.8 3.2 360 432 510 30/50/100 27 / 32 27 815 700 295 6 12 3.6 4.0 450 540 630 30/50/100 28 / 35 27 815 700 295 6 12 4.5 5.0 600 720 840 30/50/100 31 / 37 33 935 700 295 6 12 0.15 0.73 0.15 0.73 0.17 0.81 0.19 0.92 5.6 7.1 6.3 8.0 720 810 870 972 1020 1440 30/50/100 30/50/100 31 / 38 31 / 38 33 42 935 1175 700 700 295 295 10 10 16 16 220-240V, 50Hz, 1 0.2 0.22 0.98 1.07 *The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 86 8.0 9.0 9.0 10.0 870 870 1080 1080 1260 1260 30/50/100 30/50/100 32 / 39 32 / 39 42 42 1175 1175 700 700 295 295 10 10 16 16 0.25 1.15 0.17 0.82 11.2 12.5 1380 – 1980 50/130 40 / 44 62 1415 740 325 10 18 14.0 16.0 1440 – 2040 50/130 42 / 45 65 1415 740 325 10 18 16.0 18.0 1770 – 2520 50/130 42 / 45 70 1715 740 325 10 18 0.29 1.31 0.4 1.9 0.42 1.95 PFFY FLOOR STANDING (CONCEALED TYPE) INDOOR UNITS PFFYP20VLRM-A PFFYP25VLRM-A PFFYP32VLRM-A PFFYP40VLRM-A PFFYP50VLRM-A PFFYP63VLRM-A Cooling Heating (m3/h) 2.2 2.5 330/390 2.8 3.2 330/390 3.6 4.0 420/540 4.5 5.0 540/660 5.6 6.3 720/840 7.1 8.0 720/930 dB(A) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43 18.5 886 220 639 6 12 18.5 886 220 639 6 12 20 1006 220 639 6 12 21 1006 220 639 6 12 25 1246 220 639 10 16 27 1246 220 639 10 16 0.04 0.19 0.04 0.19 0.06 0.29 0.085 0.40 0.1 0.46 MODEL REFERENCE CAPACITY (kW) AIRFLOW (Low/High) NOISE* (Low/High) WEIGHT DIMENSIONS (mm) (kg) Width Depth Height PIPE SIZE ø (mm) liquid gas ELECTRICAL SUPPLY (V, Freq., Phase) INPUT POWER (kW) RUNNING CURRENT (A) 220-240V, 50Hz, 1 0.065 0.32 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber PFFY FLOOR STANDING (CABINET TYPE) INDOOR UNITS MODEL REFERENCE PFFYP20VLEM-A PFFYP25VLEM-A PFFYP32VLEM-A PFFYP40VLEM-A PFFYP50VLEM-A PFFYP63VLEM-A CAPACITY (kW) Heizleistung AIRFLOW (Low/High) Cooling Heating (m3/h) 2.2 2.5 330/390 2.8 3.2 330/390 3.6 4.0 420/540 4.5 5.0 540/660 5.6 6.3 720/840 7.1 8.0 720/930 NOISE* (Low/High) dB(A) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43 23 1050 220 630 6 12 23 1050 220 630 6 12 25 1170 220 630 6 12 26 1170 220 630 6 12 30 1410 220 630 10 16 32 1410 220 630 10 16 0.04 0.19 0.04 0.19 0.06 0.29 220-240V, 50Hz, 1 0.065 0.32 0.085 0.40 0.1 0.46 WEIGHT DIMENSIONS (mm) (kg) Width Depth Height PIPE SIZE ø (mm) liquid Anschlüsse, außen ø (mm) gas ELECTRICAL SUPPLY (V, Freq.,Phase) INPUT POWER (kW) RUNNING CURRENT (A) *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber 87 City Multi System Control – Standard Remote Control ● PAR-20MAA PAR-20 MAA to connect at the indoor unit, building of groups of seperate Databus System possible ● 1 Indoor unit individual, 1 Group with 16 indoor units possible by two-wire signal lines ● Easy to read, easy to operate display ● On/Off Timer ● Temperature selection in 1°C units ● Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. ● Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. ● PAR-F27 MEA PAR-F27 MEA to connect at the City Multi Databus System, easy to form groups ● 1 Indoor unit individual / 1 Group with16 indoor units ● Easy to read, easy to operate display ● Extensive time function ● Temperature selection in 1°C units ● Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. ● Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. ● Limit temperature setting To simplify operation of the system, the range of controls has been limited to START/STOP, room temperature and fan speed ● The only wiring required is cross-over wiring based on two-wire signal lines ● Room temperature sensors are built-in The indoor unit can be replaced with body thermostats ● Easy-to-read, easy-to-operate icon display ● Temperature selection ● Can operate all types of indoor units ● Standardized remote controllers for all indoor units ● 1 indoor unit individual/1 group with 16 indoor units ● PAC-SE51 CRA – Grouping addressing by data bus ● PAC-YT51 CRA – Main grouping by two-wire signal lines ● PAC-SE51 CRA PAC-YT51 CRA* Operating status readout Exposed type *Since this system has no operation mode switching, test operation, self-diagnosis or linked setting functions, it should always be used in conjunction with the PAR-F27MEA or other centralized controller. 88 City Multi System Control Accessories – Infrared-, Group- and System Remote Control – Timer PAR-FL31MA Infrared-Remote Control PAR-FL31 MA and PAR-FA31 MA (Signal receiver) ● ● ● PAR-FA31MA It can operate in a group system without requiring address settings When operating, it displays LED lamps. When errors occure, the error can be shown by the LED flash count 1 Indoor unit individual/1 group with 16 indoor units by two-wire signal lines Group Remote Control PAC-SC30 GRA ● Easy to read, easy to operate display Temperature selection in 1°C units ● Auto-diagnosis-display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. ● 8 Indoor units individual / Max. 16 Indoor units in 8 groups ● PAC-SC30GRA Programme Timer PAC-YT32 PTA ● ● ● One-week scheduling by remote controller Set-back function Control for PAR-F27 MEA (1 Indoor unit individual / 1 group with 16 indoor units) PAC-YT32 PTA 89 City Multi System Control Accessories – Infrared-, Group- and System Remote Control – Timer On/Off Remote Controller PAC-YT40 ANRA ● ● Up to 50 groups Price competitive solution, up to 50 indoor units PAC-YT40 ANRA System Remote Controller PAC-SF44 SRA ● ● ● ● ● PAC-SF44SRA ● Control range as Standard Controller (Air Outlet Angle/Air Filter) Limited room air temperature selection Auto diagnosis system 50 indoor units individual/max. 50 indoor units with 50 groups Lock-out function for PAR-F27 MEA External Input/Output System Timer PAC-YT34 STA ● ● ● ● ● PAC-YT34 STA 90 ● Directly connected to the M-Net databus 50 groups/max. 50 indoor units Timer-controlled mode Timer-controlled temperature 9 Timer functions Lock-off selection (On/Off/Mode/Temperatue) City Multi The New Controller G-50 A – The Next Controller Generation ● Simple and flexible The central controller G-50 A is equally suitable for small and large systems. ● Web browser Use a standard web browser on your PC, e.g. Microsoft Internet ExplorerTM, to operate and monitor the air-conditioning unit, which is connected to your local Intranet, in comfort. ● Integrated software The easy to understand operating software is already integrated in the G-50 A. This represents Mitsubishi Electric’s own innovation and is not Windows-based. It is therefore impossible for hackers to spy in your system data. ● Three password levels You can safeguard against unauthorised access to the air-conditioning system on three operating levels which are individually protected by passwords of your choice. – Access to an air-conditioning unit (or group) e.g. for each office/floor but without the possibility to change the system settings – Access to group and maintenance functions, e.g. for in-house technicians – Access to the entire system, e.g. for the system administrator ● Remote access You can also operate your air-conditioning system with your PC by remote control via your local intranet or phone connection. The access is protected by a password of your choice. ● Automatic alarm If an error occurs, the G-50 A sends a message with the most important information to a mobile phone (SMS) or an email to an address of your choice. ● Always up-to-date Upgrades with continuously updated special functions are available for the G-50 A. Examples: – Energy consumption data for individual cost statements – Special economy programmes – Annual schedules G-50A HARDWARE FOR G-50A Pos. 1 2 3 4 5 6 Type G-50A - Standard G-50A - Pro PAC-SC 50 KUA BTX-1000 PC* with software TG 2000 Watt Hour Meter Description Standard central controller for 50 air conditioners As above G-50 incl. Web function & annual schedule, programmed for clients demand Power supply unit for G-50 Router according to ME specification & installation is required depending to clients demands PC according Me specification & installation with OS, Internet Explorer and software TG 2000 Amount of WHM is depend of the project SOFTWARE FOR G-50A Web Function Personal Web RC Power consumption Ratio Demand Control I Demand Control II Annual Schedule Data Export Error scanning function Auto Alarming Service BACnet PLC Set free Homepage Remote Control via PC Calculate individual cost*** Limit temperature range, optimize indoor-outdoor unit** Peak Cut*** only connection with PLC + PLC Software Weekly and Yearly Timer** Trend Graph*** Monitoring Error History Auto Alarm function – Error Code mailing Maintenance Tool function BACnet Connection PLC connection direct with G-50 via RJ45 TG 2000 Installation TG 2000 software according customer requirement * Computer periphery like Monitor, Keyboard, Mouse, Printer from client ** Operation with G-50 or Pos. 5 *** Additional pos. 5 nessassary, for Power consumption ration additional Pos. 6 nessassary 91 City Multi – Central Remote Control – LonWorks® Interface – Maintenance Tool Lon Works®-Interface L-MAP02-E ● Easy connection of City Multi Systems through LMAP02-E, the Lon Works®-M-Net protocol converter, the total system requirements of engineers and end-users can be met more effectively and simply. ● 1 Lon Works®-Interface manages 50 indoor units. Maintenance Tool - CMS-MNF-B ● Using Maintenance Tool is the easiest way for controlling, servicing and operating the City Multi system. All system information will be displayed on personal computer* screen based on Windows Software and settings can be changed. ● In addition, error code numbers are output onto the display. ● Easy maintenance is assured through the trouble history printer output and call functions. Besides ths connection with modem and data transfer is possible. CMS-MNF-B consists of converter box and software, RS-232 cable (cross) is needed. * Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, free space 10 MB on HDD. 92 City Multi Accessories CONTROLS MODEL REFERENCE PAC-SF48MA-E PAC-SE40TS-E PAC-725AD PAC-SA88HA-E PAC-SF46EPA DESCRIPTION A to M-Net transmission converter Temperature sensor Remote indicator (Pack of 10) Remote indicator (Pack of 1) Transmission booster ACCESSORIES MODEL REFERENCE PLFY-P-VKM/VAM-A PAC-SE06WP-E PAC-SE01AS-E PAC-SE60AS-E Wide panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P80/100/125 VAM-A PAC-SE13FK-E PAC-SG01KF High efficiency filter for PAC-SE21TM-E High efficiency filter for PAC-SG03TM-E PAC-SE21TM-E PAC-SG03TM-E Multifunction casement for PLFY-P32/40/50/63 VKM-A Multifunction casement for PLFY-P80/100/125 VAM-A PCFY-P-VGM-A PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E High efficiency filter for PCFY-P40 VGM-A High efficiency filter for PCFY-P63/100 VGM-A High efficiency filter for PCFY-P125 VGM-A PAC-SE84DM-E PAC-SE85DM-E PAC-SE86DM-E Drain pump for PCFY-P40 VGM-A Drain pump for PCFY-P63 VGM-A Drain pump for PCFY-P100/125 VGM-A PEFY-P-VML/VMH-A PAC-KE04DM-F PAC-KE32LAF-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F Drain pump for PEFY-P-VMH-A Replacement filter for PEFY-P20/25/32 VML Optional filter for PEFY-P40/50/63 VMH Optional filter for PEFY-P71/80 VMH Optional filter for PEFY-P100/125/140 VMH Optional filter for PEFY-P200/250 VMH Filter box for PEFY-P40/50/63 VMH Filter box for PEFY-P71/80 Filter box for PEFY-P100/125/140 Filter box for PEFY-P200/250 PEFY-P-VMM-A PAC-KE03DM-F PAC-KE32EDF-F PAC-KE50EDF-F PAC-KE80EDF-F PAC-KE125EDF-F PAC-KE140EDF-F Drain pump for PEFY-P-VMM-A Round duct flange for PEFY-P20/25/32 VMM-A Round duct flange for PEFY-P40/50 VMM-A Round duct flange for PEFY-P63/71/80 VMM-A Round duct flange for PEFY-P100/125 VMM-A Round duct flange for PEFY-P140 VMM-A PU(H)Y-P/PURY-P-YMF-B/C PAC-KBU02MT-F PAC-KBU03MT-F REFRIGERANT PIPES CMY-R160-H CMY-R160-HA CMY-Y102S-F* CMY-Y102L-F* CMY-Y202-F* CMY-Y302-F* CMY-Y104-F* CMY-Y107-F* CMY-Y1010-F* CMC-30A DESCRIPTION High static pressure motor, 30 PA for PU(H)Y-/PURYP200/250 YMF-C High static pressure motor, (30) 60 PA for PU(H)Y-/PURYP200/250/315 YEM-A Junction pipe kit for BC-Controller Junction pipe kit for BC-Controller 2 x CMY-R160-H Joint for capacity 160 or below Joint for capacity from 161 up to 330 Joint for capacity from 331 up to630 Joint for capacity 631 or above Header (4 branch) Header (7 branch) Header (10 branch) Super Y Kit *you can use also Standard T-Branch 93 Lossnay Ventilation Systems with heat recovery VL-Series/LGH-Series The sophisticated heat recovery technology of the Lossnay Element saves energy even while keeping your room comfortable. The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room. The system’s benefit is to use the released cooling or heating energy for fresh air conditioning. 94 • Ventilation without wasting energy Ventilation of buildings can waste considerable amounts of heating or cooling energy. The Lossnay system can utilise a high percentage of this energy to cut operating costs between 20% and 50% of the power what would otherwise be required to maintain a constant temperature. • Save capital costs too By utilising this lost energy, the capacity of installed heating and cooling systems can also be reduced, with a consequent saving in capital costs of up to 30%. Lossnay units are designed to keep exhaust air and fresh air completely separate and yet still achieve an efficiency in the range of 60% to 70%. The fresh air then enters the room at a similar temperature to be expelled air, to provide comfortable environmental conditions all year round. • Lossnay at work - and at home Lossnay total heat exchange ventilators are available in ranges for both commercial installations and residential use. LOSSNAY HEAT EXCHANGE SYSTEM Stale air expelled outside Outside air is drawn in Stale internal air recovery Renewed internal air Operating range Lossnay system VL-Series: t = -10°C bis 40°C, ϕ = 60% max LGH-Series: t = -10°C bis 40°C, ϕ = 80% max 95 Lossnay VL-Series Wall Mounted Systems Model VL-100 LOSSNAY-VL-SERIES MODEL REFERENCE ELECTRICAL SUPPLY (V, PHASE,Hz) POWER INPUT (W) AIRFLOW (m3/h) NOISE* dB(A) EFFICIENCY (%) WEIGHT (kg) DIMENSIONS (mm) DUCT SIZE VL-100U-E 220-240, 1, 50 Low High Low High Low High Low High 23 26 65 105 29.5 39 77 70 6.5 620 168 265 2x75ø Width Depth Height (mm) To install the units of the Lossnay Series VL-100 only 2 x 75 mm diameter bores are necessary. Supply and return air ducts and protective caps against invading rain water are included in delivery. The units operate very quietly, selection between 2 fan speed levels is possible, the unit will be switched on/off by pull string. * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Lossnay LGH-Series Ceiling Suspended Systems Model LGH-40ES-E LOSSNAY-LGH-SERIES MODEL REFERENCE LGH-40ES-E ELECTRICAL SUPPLY (V, PHASE,HZ) 220-240, 1, 50 POWER INPUT (W) low high 88 138 RUNNING CURRENT (A) low high 0.4 0.6 AIRFLOW (m3/h) low high 250 400 STATIC PRESSURE (Pa) low high 10 40 NOISE* dB(A) low high 33 42 TEMPERATURE RECOVERY (%) EFFICIENCY low high 70 60 ENTHALPY RECOVERY (%) EFFICIENCY low high 52 45 WIDTH DEPTH HEIGHT 900 693 255 WEIGHT (kg) 25 DIMENSIONS (mm) DUCT SIZE (mm) 2 x 200 ø OPTIONAL PARTS MODEL REFERENCE PZ-03SLP-E Switch ON/OFF and Airflow * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber 96 • Compact Design A mere 255 mm from front to back, this thin design takes up a minimum of space even when suspended from the ceiling of an existing building. • Minimal installation needs In addition to this lightweight and compact design, connection to the outdoor unit requires just a 200 mm. • Saves energy The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room while ventilating, making this unit both economical and environmentally friendly. • A refined design Designed to eliminate the outflow of air to the space directly beneath the unit, there is no worry of discomfort from drafts. Lossnay LGH-Commercial Series Models LGH-15 to 200 RX ● Saves between 20% and 50% of the energy that would otherwise be lost by ventilation ● Saves up to 30% on initial capital costs of heating and cooling plant due to Lossnay’s ability to utilise heating or cooling energy that would otherwise be wasted ● Automatically humidifies or dehumidifies incoming air to match required interior conditions ● Supply air and exhaust air are kept strictly separated to ensure inbound air is always fresh ● Supply air is heated or cooled as required to match room conditions ● Provides comfortable ventilation through introduction of fresh air, helping to provide a healthy working environment ● Minimal Maintenance ● Easily replaced Lossnay element LOSSNAY-LGH-SERIES MODEL REFERENCE ELECTRICAL SUPPLY (V,PHASE,Hz) RUNNING CURRENT POWER INPUT (W) AIRFLOW (m3/h) STATIC PRESSURE (Pa)* NOISE** dB(A) EFFICIENCY % WEIGHT (kg) DIMENSIONS (mm) (A) Low Medium High*** Low Medium High*** Low Medium High*** Low Medium High*** Low Medium High*** Width Depth Height DUCT SIZE (mm) LGH15RX LGH25RX LGH35RX LGH50RX 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 0.52 52 74 104 120 150 150 25 40 90 21 24 26 80 77 77 19 610 780 275 100ø 0.55 54 91 111 165 250 250 20 40 65 21 25 27 93 78 78 23 735 780 275 150ø 0.82 97 154 169 230 350 350 25 70 150 23 28 31 84 79 79 33 874 888 317 150ø 0.96 123 193 204 350 500 500 30 60 150 24 30 32 82 77 77 38 1016 888 317 200ø LGH80RX LGH100RX 220-240,1,50 220-240,1,50 1.8 304 368 392 670 800 800 70 100 140 30 32 34 81 78 78 73 1004 1164 398 250ø 2.3 465 495 500 870 1000 1000 80 100 160 32 34 36 81 79 79 83 1221 1164 398 250ø LGH150RX LGH200RX 220-240,1,50 220-240,1,50 3.3 585 670 720 1200 1500 1500 50 100 137 33 36 37 81 79 79 175 1004 1662 800 350ø 4.6 900 995 1000 1400 2000 2000 83 80 137 36 37 39 83 79 79 194 1231 1662 800 350ø *** Refering to the airflow in the table *** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Extra high ventilation step to increase stat. pressure ACCESSORIES LOSSNAY MODEL REFERENCE PZ-41SLB PZ-52SF DESCRIPTION WIRED REMOTE Control for independent operation Remote Controller for City Multi System 97 MJ-E16PX Dehumidifier to operate by LCD • Easy display operating modes: low, • 3high and auto Large water container (6 L) • stop by overflow • Automatic protection • Timer: 1 – 9 hours operation • Air filter • Display of defrost • Waterlevel visible • Hygrostat of humidity • Display (50%, 60%, 70%) restart after • Automatic voltage break up to 16 litres • Collects of moisture in a 24 hours • • • period Compact, unobstrusive and quiet in operation Low energy consumption Environment-friendly refrigerant R134a Compact and efficient MJ-E16PX seems unobstrusive and is portable because of its grip and weight (12.9 kg). Additional Advantages the time of drying your clothes on • Reduces the line of a hose possible to transport the • Installation condensate water MJ-E16PX MJ-E16PX DEHUMIDIFYING CAPACITY Litres/24 hours 10°C/70% rel. humidity 27°C/60% rel. humidity 30°C/80% rel. humidity TECHNICAL DATA Water container (I) Auto Stop (I) Weight (kg) Dimensions (mm) Width Depth Height Supply voltage (V, Phase, Hz) Power consumption (W) Noise dB(A) Low in fan operation High Operating temperature min. max. Compressor type Refrigerant Colour 98 3.1 9.0 16.0 5.0 5.0 12.9 360 281 569 220-240, 1, 50 280 33 35 1°C 40°C Rotary R134 a white CONTROL FUNCTIONS Mode button Timer button Control lamp Tank full lamp Defrost lamp Humidity lamp selects low, high and auto press to set operation time 1 – 9 hours or permanent shows adjustment lights when water tank needs emptying light is on during defrost operation lights when extremely high rel. humidity, audible signal for rel. humidity more than 70% Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B. V. The Company reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Art. No. 154384 © 05/2004 MITSUBISHI ELECTRIC EUROPE B.V. AIR CONDITIONING DIVISION GOTHAER STR. 8 D-40880 RATINGEN GERMANY TEL.: +49-2102-486-1800 FAX: +49-2102-486-7910 www.mitsubishi-electric-aircon.de