Model GT 1175 Electrical Installation Manual **with U30

Transcription

Model GT 1175 Electrical Installation Manual **with U30
S82 W18717 Gemini Drive
Muskego, Wisconsin 53150
Phone: (877) 622-2694
Fax: (888) 679-3319
www.nabcoentrances.com
Technical Support: (866) 622-8325
Model GT 1175
Electrical Installation Manual
**with U30 Microprocessor Controller**
(with Revision D Software)
HANDY TERMINAL HARNESS
P/N 14-11837
INDICATORS
TB2
GROUND LUG
SCREW TO HEADER
ON/OFF
POWER
SWITCH
GROUND HARNESS
P/N 14-11872
FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(COMMON)
INTERIOR ACTIVATION
HOLDING BEAM
REDUCED OPENING SWITCH
6B
H
62
BA
ERROR
AC115V ± 10%
50 / 60 Hz
BLACK (HOT)
WHITE (COMMON)
61
POWER・2P
20VAC 50/60Hz
S1
TRANSFORMER
5
A
M
P
MADE IN JAPAN
R1
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
MOTOR・12P
POWER
DS-150NA
ZN
TB1
WARNING
T1
GYRO TECH
NOISE
FILTER
(24-11327)
ZN
R2
U30 CONTROL P/N 24-8901-30
MOTOR/OPERATOR P/N 24-11327
GYRO TECH
HANDY TERMINAL・6P
No.
Microprocessor Controller
248901-
Mode SW Usage
M0
M1
MODE
Open Open TWO WAY
FUNCTION [SLIDING DOOR]
Gnd Open ONE WAY 12VDC+
Gnd
Gnd HOLD OPEN 12VDC-(Common)
Open Gnd NIGHT
Interior Activation
Holding Beam
Reduced Opening Switch
CAUTION
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
There are no user serviceable parts
inside.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
SYMBOL No.
9DC12V 1
7
2
61
3
6B
4
H
5
M0
6
M1
7
62
8
9
SQ
BA
10
11
SLS
N/O
OUT.A 12
N/C
OUT.B 13
Common OUT.C 14
OUT
15
16
7
Mode Switch (see Mode SW Usage shown left)
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
RELATED DEVICES・16P
POWER SUPPLY P/N 14-11741
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
POWER SUPPLY HARNESS
P/N 14-11874
120 VAC
AUXILIARY 120 VAC
POWER WIRES
(THESE WIRES NORMALLY
COILED AND TIED UP)
RELATED DEVICES - 16P
SYMBOL No.
9DC12V 1
1
7
2
2
61
3
3
6B
4
4
5
H
5
6
M0
6
Mode Switch (see Mode SW Usage shown left)
7
M1
7
Exterior Activation
8
62
8
Sequential Activation
SQ
9
9
Breakout Detector
10
BA
10
11
Sidelite Presence Sensor
SLS
11
GRAY (OUT A)
Contact Output (Class2 Load only)
12
N/O
OUT.A
12
30V(42.4Vpeak)max.
13
N/C
OUT.B
13
VIOLET
5Amax.(0-20V), 3.2Amax.(20-30V)
14
14
Common OUT.C
Auxiliary Output (Open-Collector)
15
OUT
15
16
7
16
12VDC-COMMON
LABEL ON U30 CONTROL
TERMINAL ON U30 MAIN HARNESS
110V
1
FAIL
SECURE
BLK
WHT
GRY
VIO
6
FAIL SECURE LOCK ASSY.
P.N. 22-10522-03
WIRING FOR ELECTRIC LOCK ONLY SHOWN
P/N 24-11877
U30 ELECTRIC STRIKE OUTPUT SIGNAL
HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE
ON
OUTPUT: 0 = ELECTRIC STRIKE OUTPUT
OUTPUT TIMER
0 = (DO NOT USE)
1 = (DO NOT USE)
2 = (DO NOT USE)
3 = ELECTRIC STRIKE FUNCTION
ACTIVATION SIGNAL
OFF
ON
OUTPUT SIGNAL
OFF
3 SEC
OPENING
OUTPUT TIMER
1.0 SEC
FULL OPEN
FULLY CLOSED
FULLY CLOSED
DN 0552
CLOSING
WARNING
• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO
trained technician. Failure to follow these practices may result in serious consequences.
• NEVER leave a Door operating without all Safety detection systems operational.
Part #15-10596-30
Rev. 1/10/14
THIS PAGE IS INTENTIONALLY LEFT BLANK
www.NabcoEntrances.com
Rev. 1-10-14
Electrical Installation Manual U-30 Control
Part #14-10596-30
Table of Contents
Warning Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
General Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
CHAPTER 1: SCOPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Section 1a: To the Installer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Section 1b: Objective. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
CHAPTER 2: GETTING STARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Section 2a: About the U30 Microprocessor Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Section 2b: Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Section 2c: Output Power Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Section 2d: Header Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
CHAPTER 3: CONNECT INCOMING 120 VAC WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
CHAPTER 4: IDENTIFY OPERATING WIRES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Section 4a: 16 Pin Controller Terminal Block Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10
Section 4b: Sensor Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Section 4c: Rocker Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
CHAPTER 5: WIRING DIAGRAMS (SURFACE APPLIED SLIDERS) . . . . . . . . . . . . . . . . 5-14
Section 5a: (2) Acusensors and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
Section 5b: (2) Optex I-One and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam Control. . . . . . . . . . . . . . . . 5-16
Section 5d: (2) Optex I-One, (1) Holding Beam and (1) Breakout Beam Control . . . . . . . . . . . . . . . 5-17
Section 5e: (2) Wizard G3, and (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
Section 5f: (2) Wizard G3, (1) Holding Beam and (1) Breakout Control . . . . . . . . . . . . . . . . . . . . . . 5-19
i
Electrical Installation Manual U-30 Control
Part #14-10596-30
www.NabcoEntrances.com
Rev. 1-10-14
CHAPTER 6: INFRARED BEAM WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20
Section 6a: Wiring (1) Holding Beam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20
Section 6b: Wiring (2) Holding Beams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
Section 6c: Wiring Holding Beam for Breakout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22
CHAPTER 7: ELECTRIC LOCK WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23
Section 7a: Adjust the Strike. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23
Section 7b: U30 with Fail Safe Electric Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24
Section 7c: U30 with Fail Secure Electric Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25
Section 7d: U30 with Magnetic Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26
CHAPTER 8: CUSTOM WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27
Section 8a: U30 Configured for Remote Control of Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27
Section 8b: Sidelite Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-28
Section 8c: U30 Using Card Readers or other Secure Activation Devices. . . . . . . . . . . . . . . . . . . . . 8-29
CHAPTER 9: TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30
CHAPTER 10: RETURN POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31
Section 10a: How to Print and Fill out a Return Material Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31
ii
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
WARNING LABELS
Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning
labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer
to this page in the event that a warning label is displayed within this manual and further definition needs to be explained.
DANGER
Indicates potentially dangerous situations. Danger is used when there is a
hazardous situation where there is a high probability of severe injury or death.
It should not be considered for property damage unless personal injury risk
is present.
WARNING
Indicates a hazardous situation which has some probability of severe injury.
It should not be considered for property damage unless personal injury risk
is present.
CAUTION
Indicates a hazardous situation which may result in a minor injury. Caution
should not be used when there is a possibility of serious injury. Caution should
not be considered for property damage accidents unless a personal injury risk
is present.
Notice:
Indicates a statement of company policy as the message relates to the personal
safety or protection of property. Notice should not be used when there is a
hazardous situation or personal risk.
Note:
Indicates important information that provides further instruction.
iii
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
GENERAL SAFETY RECOMMENDATIONS
WARNING
Do not install, operate or service this product unless you have read and
understand the General Safety Recommendations, Warning Labels, contained in
this manual. Failure to do so may result in bodily injury, or property damage.
WARNING
Read, study and understand the installation and operating instructions contained
in, or referenced in this manual before operating. If you do not understand the
instruction, ask a qualified technician. Failure to do so may result in bodily injury,
or property damage and will nullify all warranties.
Notice:
Disconnect all power to the junction box prior to making any electrical
connections. Failure to do so may result in seriouc personal or fatal injury. When
uncertain whether power supply is disconnected, always verify using a voltmeter.
DANGER
iv
This manual and the owner’s manual must be given to and retained by the
purchasing facility or end user.
Notice:
Wiring must meet all local, state, federal or other governing agency codes.
Notice:
All electrical troublshooting or service must be performed by qualified
electrical technicians and must comply with all applicable governing
agency codes.
DANGER
Do not place finger or uninsulated tools inside the electrical controller. Touching
wires or other parts inside the enclosure may cause electrical shock, serious
injury or death.
CAUTION
The Ground wire from the Magnum IV Control 120 VAC Harness, and the Incoming
120 VAC Ground wire must be connected to the Ground screw located within the
Swing door Header.
CAUTION
If the door appears broken or does not seem to work correctly, it should be
immediately removed from service until repairs can be carried out or a qualified
service technician is contacted for corrective action.
Note:
All Adjustments must be made with a small screwdriver. Do Not use a pencil.
Note:
Do Not take shortcuts.
www.NabcoEntrances.com
Rev. 1-10-14
Electrical Installation Manual U-30 Control
Part #15-10596-30
CHAPTER 1: SCOPE
Section 1a: To the Installer
The purpose of this manual is to familiarize the installer and purchaser with the proper
installation and operation of this system. It is essential that this equipment be properly installed
and operational before the door is used by the public. It is the installer’s responsibility to inspect
the operation of the entrance system to be sure it complies with any applicable standards.
Instruct the building owners and operator on the essentials of the operation of the U30
Microprocessor Controller. The owner should follow these instructions to determine whether the
door is operating properly and should immediately call for service if there is any malfunction. All
installation changes and adjustments must be made by qualified, NABCO trained technicians.
Section 1b: Objective
The U30 Microprocessor Controller is designed to be installed within the Header of the GT-1175
Slide Door systems.
This manual offers step by step instructions.
Scope
1-5
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
CHAPTER 2: GETTING STARTED
Section 2a: About the U30 Microprocessor Control
The U30 Microprocessor Control is utilized on all GT-1175 Slide Door systems to control
numerous operating characteristics that include (but not limited to): speed, recycling sensitivity
and reduced opening width.
Note:
The U30 Microprocessor Control will need to be programmed after installation is complete.
The U30 Microprocessor Control is also utilized to output power to accessories and/or auxiliary
equipment such as:
►►Sensors
►►Modules
There are times when the U30 Microprocessor Control is not utilized to output power because
some accessories and/or auxiliary equipment are shipped with it’s own dedicated power supply.
Section 2b: Electrical Specifications
All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits
that are installed at the NABCO Factory. The low voltage Reed Switch (12 VDC) and Sensor(s) are
also installed complete with connector housings at the NABCO Factory.
Note:
NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and
connector housings to manufacture GT-1175 Slide Door systems.
Table 2-1 Sensors
Sensor
Acusensor 3
Wizard G3
Optex i-one
Part Number
14-8902-3
14-13316
14-13036
Table 2-2 Modules
Module
Optex Beam
CP/RX Radio
Control Receiver
2-6
Function
Infrared
Power Source
Infrared + Microwave
Infrared
Part Number
14-9710-01
24-11467
12 to 24 AC or DC
12 to 24 VAC or VDC
12 to 24 VAC or 12 to 30 VDC
Function
Beam & Control
Power Source
12 to 24 AC or DC
RF Signal Transmission 12 to 24 AC or DC
Current Consumption
100mA
250mA (ea.unit) at 12VDC
130mA
Current Consumption
160mA
50mA
(ea.unit) at 12VDC
Getting Started
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
Section 2c: Output Power Guidelines
TOTAL current draw from the U30 Microprocessor Control must not exceed 350 mA (0.35 amps)
when outputting power to:
►►Sensors
►►Modules
►►Accessories
►►Auxiliary Equipment
CAUTION
If TOTAL current draw exceeds 350mA (0.35 amps) the installer must utilize an auxiliary power
supply such as a 24 VAC Transformer (P/N 14-2101).
The U30 Microprocessor Control and/or the NABCO Power Supply Module Must
Not be used to output power to Magnetic Locks or Electric Strikes.
To determine if an auxiliary power supply must be used, add together each current draw for each
device. Please refer to the formula shown below:
Example: A GT-1175 Slide Door is to be fitted with the following devices:
2 x Optex i-one Sensors @ 130 mA = 260 mA
1 x Optex Beam Module @ 160 mA = 160 mA
Total = 420 mA
420mA exceeds 350mA. An Auxiliary Power Supply must be used to supply
power to the Optex Beam Module.
Section 2d: Header Layout
Nabco GT-1175 Sliding Door systems come in many sizes and configurations. Because of this
components within the Header are layed out in (1 of 3) different configurations to ensure proper
operation of the Drive Belt. Please see configuration details listed below:
►►Operator/Control/Power
•
Header Width is not wide. Operator needs to be installed to the left of the U30
Microprocessor Control. Please see Figure 2-1.
•
Header Width is wide, but Operator still needs to be installed between the Power Supply
and the U30 Microprocessor Control. Please see Figure 2-2.
•
Header Width is wider. Operator can be installed to the right of the Power Supply and
the U30 Microprocessor Control. Please see Figure 2-3.
►►Power/Operator/Control
►►Power/Control/Operator
Note:
Note:
Getting Started
The Power Supply must never be installed between the U30 Microprocessor Control and the Operator.
No matter the location, electrical wiring for all (3) components stays the same.
2-7
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
U30 Microprocessor Controller
Header
INDICATORS
POWER・2P
20VAC 50/60H
432
765
Operator
To maintain warranty,repairs must e
made y authori ed NABCO facilities.
No.
HANDY TERMINAL・6P
Mode Switch (see Mode SW Usage shown left)
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NR
NR
2
1
TB1
TB2
S1
Power Supply
Figure 2-1 Header Layout “OCP” with or without Electric Lock
Operator
A RNING
T1
TRANSFORMER
LABEL
M<
To protect against risk o ire or electric shock,use only the
certi ied NABCO power supply.
MOTOR・12P
PO E R
61
GYRO TECH
DS-150NA
INDICATORS
R2
1
>PO
NOISE
FILTER
ZN
ZNR
O
5
A
M
P
TB1
(24-11327)
TB2
6B
PO E R・2P
20VAC 50/60H
98
I
432
11
10
1 12
Mode S Usag e
MODE
M1
Open
T O AY
Open
ONE AY
Gnd HOLD OPEN
Gnd
NIGHT
CAUTION
BA
ERROR
7 0
M0
Open
Gnd
Gnd
Open
GYRO TECH
H
62
MADE IN JAPAN
S1
Ad ustments to the door can only e mad
e
with the NABCO Handy Terminal.
Do not disassem le the control ox.
There are no user servicea le parts
inside.
To maintain warranty,repairs must e
made y authori ed NABCO acilities.
765
Power Supply
HANDY TERMINAL・6P
No.
Microprocessor Controller
248901FUNCTION [SLIDING DOOR]
12VDC
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode S Usage shown le t)
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V )
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RELATED DEVICES・16P
Header
DN 0536
T1
NOISE
FILTER
Microprocessor Controller
248901FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
TRANSFORMER
LABEL
M<
98
DN 0537
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gnd HOLD OPEN
Gnd
NIGHT
CAUTION
Ad ustments to the door can only e mad
e
with the NABCO Handy Terminal.
Do not disassem le the control ox.
There are no user servicea le parts
inside.
RELATED DEVICES・16P
>PO
10
7 0
M0
Open
Gnd
Gnd
Open
GYRO TECH
H
62
I
11
O
61
6B
BA
ERROR
1 12
5
A
M
P
WARNING
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
MOTOR・12P
POWER
GYRO TECH
DS-150NA
(24-11327)
MADE IN JAPAN
U30 Microprocessor Controller
Figure 2-2 Header Layout “POC” with or without Electric Lock
Header
Operator
M0
Open
Gnd
Gnd
Open
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gnd HOLD OPEN
Gnd
NIGHT
CAUTION
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
There are no user serviceable parts
inside.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
No.
HANDY TERMINAL・6P
Microprocessor Controller
248901FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Senso r
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V )
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL No.
9DC12V 1
7
2
61
3
6B
4
5
H
M0
6
M1
7
8
62
SQ
9
10
BA
SLS
11
OUT.A 12
OUT.B 13
OUT.C 14
15
OUT
16
7
GYRO TECH
DS-150NA
(24-11327)
MADE IN APAN
1 12
432
NABCO
GYRO TECH
RELATED DEVICES・16P
INDICATORS
H
62
O
5
A
M
P
I
POWER・2P
20VAC 50/60Hz
TRANSFORMER
LABEL
61
6B
BA
ERROR
11
7 0
765
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
MOTOR・12P
POWER
TB2
98
Power Supply
2-8
WARNING
T1
10
DN 0535
S1
M
R2
1
>PO
NOISE
FILTER
ZN
ZNR
TB1
U30 Microprocessor Controller
Figure 2-3 Header Layout “PCO” with or without Electric Lock
Getting Started
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
CHAPTER 3: CONNECT INCOMING 120 VAC WIRES
Disconnect power to the junction box prior to making any electrical connections.
Failure to do so may result in serious personal or fatal injury. When uncertain
whether power supply is disconnected, always verify using a voltmeter.
DANGER
Notice:
Wiring must meet all local, state, federal or other governing agency codes.
1. Ensure all power is disconnected at the Junction box.
2. Ensure all power to the GT-1175 Slide Door is Off.
3. Inspect the location and grade of all Incoming 120 VAC power cables.
4. Insert all Incoming 120 VAC, single phase, 5 amp (minimum) power wires into the pre drilled
Electric Service Access Hole located at the left or right side of Jamb Tube and Header End Cap.
a. It is recommended for the Installer to house all Incoming 120 VAC wires within an
Electrical Conduit.
Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header.
CAUTION
Do Not route 120 VAC wires near the U30 Microprocessor Controller and Operater.
CAUTION
5. Please see Figure 3-1, to follow steps on how to connect Incoming 120 VAC wires to
Power Supply.
6. Go to the TB1 Port located on the Left side of the Power Supply Module.
7. Insert the Incoming 120 VAC Black (HOT) wire into the Circuit marked “L”.
8. Insert the Incoming 120 VAC White (Neutral) wire into the Circuit marked “N”.
9. Insert Green (Grounding) wire into the Circuit marked “PE”.
Read and understand the “U30 Controller Setup and Programming Manual”
P/N 15-9000 before attempting to power-up the GT-1175 Slide Door. Failure to do
so may result in damage to the Slide door and/or injury to the installer and will
nullify all warranties.
DANGER
Black Wire (Hot)
NABCO
N
NA
DS-1500
D24-113270
GYRO TECH
6B
INDICATORS
LOAD
H
32
ERROR
11
1 12
7 0
M0
Open
Gn d
Gn d
Open
!
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
There are no user serviceable parts
inside.
!
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gn d
HOLD OPEN
Gn d
NIGH T
! CAUTION
62
BA
MADE IN JAPAN
4
S1
GYRO TECH
Nabtesco Corporation
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
! WARNING
To protect against risk of Fire
or electric shock,use only the
!
NABCO
61
7 6 5
PRESS
TO
RESET
MOTOR 12P
POWER
8
Grounding Wire
-CIRCUIT-BREAKERRED INDICATES
POWER IS OFF
O
10 9
(Common)
TB1
BC
NABCO
POWER 2P
20VAC 50/60Hz
PE
White Wire
TB2
To maintain warranty,repairs must be
made by authorized NABCO facilities.
No.
HANDY TERMINAL 6P
Microprocessor Controller
248901FUNCTION (SLIDING DOOR)
12VDC +
12VDC-(Common)
Interior
n
Holding Beam
Reduced Opening Switch
Exterior
A
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT. A
OUT. B
OUT. C
OU T
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RELATED DEVICES・16P
T1
>PO
M<
L
NOISE
FILTER
ON/OFF
Power Switch
P/N 14-11872
Connect Incoming 120 VAC Wires
DN 0538
Figure 3-1 Connect Incoming 120 VAC Wires to Power Supply
3-9
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
CHAPTER 4: IDENTIFY OPERATING WIRES
Section 4a: 16 Pin Controller Terminal Block Assignments
Note: All wires are identified by color. All references to signals are made in connection with Common (Red).
Note: Use a flat-blade screwdriver to remove the Terminal Connector from the U30 Microprocessor Controller.
Ensure that all wires are matched to each appropriate Terminal. Each Terminal is numbered with
corresponding information on the Face Plate of the U30 Microprocessor Controller.
Note: Common Terminal indicates terminal can be Output or Input.
* Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red
indicates a Black wire with a Red Stripe.
Terminal #
Symbol
Color
1
9DC12V
Brown
2
7
Red
4-10
Description
XX Output terminal
• Sensor power source.
• Output is 12VDC with a maximum capacity of 350mA (.35 amp).
XX Common terminal
• Provides common ground for the 12 VDC power and signal source.
3
61
Black
4
6B
White
5
H
Green
6
M0
Orange
7
M1
8
62
Orange/ XX Input terminal
White*
• Mode Switch Two (SW2).
• Used to acheive special functions. Please refer to “Switch Settings”
section within this chapter.
9
SQ
Black/
Red*
Yellow
XX Input terminal
• Interior Activation signal.
• Opens the door in two-way and one-way modes only.
XX Input terminal
• Holding Beam signal.
• Opens or re-opens a Sliding door.
XX Input terminal
• Reduced Opening Switch signal.
• Reduces Slide door opening when switched to Red (7).
XX Input terminal
• Mode Switch One (SW1).
• Used to acheive special functions. Please refer to “Switch Settings”
section within this chapter.
XX Input terminal
• Exterior Activation signal.
• Opens the door in two-way mode only.
XX Input terminal
• Sequential Activation signal.
• Allows a sequence of signals to open and close Slide door.
Identify Operating Wires
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
Terminal #
Symbol
Color
10
BA
Blue
11
SLS
12
OUT A
Green/
White*
13
OUT B
15
OUT
14
OUT C
16
7
Gray
Gray
Violet
Description
XX Input terminal
• Breakout Detector signal.
• Connected to Red (7) during normal operation.
• Disconnected from Red (7) during ‘stop door’ operation. Will
happen if:
• Switch is turned OFF
• Slide door is panicked open
XX Input terminal
• Sidelite Presence Sensor.
• At fully closed position, input will prevent Slide door from opening.
XX Auxiliary Output terminal
• Connected to Normally Open contact on an internal relay.
• Referred to as ‘Auxiliary Relay Output” throughout manual.
• Used as a Switch to:
• Sequence an Electric Strike.
• Control other Slide doors in an air lock situation.
• Signal a remote computer on the Slide door operation.
XX Auxiliary Output terminal
• Connected to Normally Closed contact on an internal relay.
XX Auxiliary Output terminal
• Common for output wire “OUT A” or ‘OUT B”
Brown/ XX Auxiliary Output 2 terminal
Yellow*
• Connected to an Internal Transistor with Open Collector in the U30
Microprocessor Controller.
• Installer must provide wire for this terminal (not normally utilized).
Red
XX Common terminal
• Provides common ground for the 12 VDC power and signal source.
Section 4b: Sensor Wire Connections
* Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red
indicates a Black wire with a Red Stripe.
** Denotes wiring that has been crimped together at NABCO factory.
Table 4-1 Acusensor
U30 Harness
Red
Black
*Black/Red
Brown
Common
Signal, Interior
Signal Exterior
Identify Operating Wires
+12 VDC
Extension Harness
Acusensor Harness
Red
**White and Red
Gray
Black
Yellow
Green
4-11
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
Table 4-2 Optex i-one
U30 Harness
Red
Black
*Black/Red
Brown
*Black/Red
Brown
Red
**Gray and White
Gray
Gray
Interior Signal
Yellow
Exterior Signal
+12 VDC
U30 Harness
Black
Optex i-one Harness
Common
Table 4-3 Wizard
Red
Extension Harness
Yellow
Extension Harness
Wizard Harness
Red
**Red and White and Brown
Gray
Black
Common
Interior Signal
Yellow
Exterior Signal
+12 VDC
Green and Blue
Section 4c: Rocker Switch Settings
OFF = Not switched to COMMON
Rocker Switch
Mode
Key Switch
Mode
Night
Night
OFF
ON
-
XX Sensors on Terminal (3) and (8) can not open the door
while door is closed.
XX Sensors on Terminal (3) and (8) will provide threshold
safety when door is in any position other than closed.
XX Electric Lock remains locked unless an activation signal
is given from a device (such as card reader, key switch,
wall plate, etc.): connected in one of two ways:
1. Between Common and MO (7)
a. This only works when door is in “Night” mode
2. Between Common and SLS (11)
a. This only works if the SLS is programmed for
activation devices.
Note: Consult the U30 Programming Manual for details;
(P/N 15-9000-30).
Hold Open
H.O.
ON
ON
-
Two Way
Auto
OFF
OFF
-
XX No activation needed when “Hold Open” is selected.
Slide door is held open.
XX Electric Lock is always unlocked.
4-12
Wire Wire Wire
M0
M1
H
ON = Switched to COMMON (RED 7)
Description
XX Sensors on Terminal (3) and (8) can both open
the door.
XX Electric Lock is always unlocked.
Identify Operating Wires
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
Rocker Switch
Mode
Key Switch
Mode
One Way
Exit
ON
OFF
-
Full Open
Full
-
-
-
-
OFF
Reduced Open
Reduced
Identify Operating Wires
Wire Wire Wire
M0
M1
H
ON
Description
XX Sensor on Terminal (3) can open the door.
• Sensor is normally Interior and used to activate door
for one-way traffic.
XX Sensor on Terminal (8) can not open the door from the
closed position.
• Sensor is normally Exterior and used to provide
threshold safety only.
• Electric Lock remains locked unless an activation
occurs from the interior sensor or by a device (such
as a card reader, key switch, wall plate, etc.) that is
connected in one of two ways:
1. Between Common and M1 (6)
a. This only works when door is in “One Way” or
“Exit” mode.
2. Between Common and SLS (11)
a. This only works if the SLS is programmed for
activation devices.
Note: Consult the U30 Programming Manual for details;
(P/N 15-9000-30).
XX Upon activation or in Hold Open mode, Slide door will
open to the full position.
XX Upon activation, Slide door will open to the Reduced
Open position.
4-13
Common
N/O
N/C
LOAD
TWO WAY
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
PN 14-11875
KEY SWITCH
FOR U30
PN 14-11876
FULL
OPEN
ORANGE
RED
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
WHITE
WHITE
WHITE
U30 TERMINAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
BLUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
WHITE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
BLUE
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
GYRO TECH
NABCO
NA
BC
O
1
1211
7 0
!
!
!
! WARNING
M0
Open
Gn d
Gn d
Open
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gn d
HOLD OPEN
NIGH T
Gn d
To protect against risk of Fire or electric shock,use only the
cerfied NABCO power supply.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
GYRO TECH
NABCO
Mode Switch (see Mode SW Usage shown le)
Exterio r Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
U30 TERMINAL
P/N 24-11877
DN 0539
OPTEX
HOLDING BEAM
CONTROLLER
PT. NO.
PN 14-9710-03
TERM #1
BROWN &RED
(CIRCUIT 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Optex OS-12C
Controller
RED
TERM #4
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WHITE
TERM #5
EXTERIOR ACUSENSOR
PT. NO. 14-8902
YELLOW
GRAY
BROWN
BLK/RED
P/N 14-11874
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT. A
OUT. B
OUT. C
OU T
7
HANDY TERMINAL 6P
Microprocessor Controller
248901-
No.
FUNCTION (SLIDING DOOR)
12VDC +
12VDC-(Common)
Interior Acvao n
Holding Beam
Reduced Opening Switch
Power Harness
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
INTERIOR ACUSENSOR
PT. NO. 14-8902
YELLOW
GRAY
BROWN
BLK
MAIN HARNESS FOR U30
P/N 24-11877
ERROR
BA
62
H
6B
61
POWER
MOTOR 12P
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
Part #15-10596-30
REDUCED OPEN
RED
BLUE
WHITE
BLUE
TB2
Auxiliary 120 VAC
Power Wires
(These wires are normally
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROL LABEL
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
NOISE
FILTER
8
12 VDC+
12VDC- (Common)
P/N 14-11872
TB1
ON/OFF
Power Switch
PE
Grounding Wire
(Common)
White Wire
AC115V ± 10%
50 / 60 Hz
MOTOR/OPERATOR
P/N 24-11327
3 2
4
INDICATORS
POWER 2P
20VAC 50/60Hz
POWER SUPPLY
P/N 14-11741
RELATED DEVICES・16P
5-14
N
7 6 5
L
10 9
Related Devices - 16P
>POM
<
Black Wire (Hot)
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Rev. 1-10-14
CHAPTER 5: WIRING DIAGRAMS
Section 5a: (2) Acusensors and (1) Holding Beam
Wiring Diagrams (Surface Applied Sliders)
Wiring Diagrams (Surface Applied Sliders)
Common
N/O
N/C
LOAD
TWO WAY
FULL
OPEN
ORANGE
RED
REDUCED OPEN
RED
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
BLUE
WHITE
WHITE
BLUE
WHITE
WHITE
U30 TERMINAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
BLUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
WHITE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
BLUE
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
GYRO TECH
NABCO
NA
BC
3 2
1
1211
7 0
!
!
M0
Open
Gn d
Gn d
Open
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gn d
HOLD OPEN
Gn d
NIGH T
! WARNING
To protect against risk of Fire or electric shock,use only the
cerfied NABCO power supply.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
GYRO TECH
NABCO
GRAY
WHITE
GRAY
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
U30 TERMINAL
P/N 24-11877
DN 0685
OPTEX
HOLDING BEAM
CONTROLLER
PT. NO.
PN 14-9710-03
TERM #1
BROWN &RED
(CIRCUIT 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Optex OS-12C
Controller
RED
TERM #4
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WHITE
TERM #5
N/O
N/C
Common
EXTERIOR OPTEX I-1
PT. NO. 14-13036
YELLOW
GRAY
YELLOW
Mode Switch (see Mode SW Usage shown le)
Exterio r Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT. A
OUT. B
OUT. C
OU T
7
HANDY TERMINAL 6P
Microprocessor Controller
248901-
No.
FUNCTION (SLIDING DOOR)
12VDC +
12VDC-(Common)
Interior Acvao n
Holding Beam
Reduced Opening Switch
BLK
BROWN
BLK/RED
OPTEX
HARNESS
P/N 12-13018
WHITE
GRAY
ERROR
BA
62
H
6B
!
MOTOR 12P
61
POWER
Power Harness
P/N 14-11874
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
INTERIOR OPTEX I-1
PT. NO. 14-13036
YELLOW
GRAY
YELLOW
GRAY
BROWN
BLK
MAIN HARNESS FOR U30
P/N 24-11877
O
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
Rev. 1-10-14
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
PN 14-11875
KEY SWITCH
FOR U30
PN 14-11876
TB2
Auxiliary 120 VAC
Power Wires
(These wires are normally
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROL LABEL
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
NOISE
FILTER
ON/OFF
Power Switch
TB1
MOTOR/OPERATOR
P/N 24-11327
RELATED DEVICES・16P
POWER SUPPLY
P/N 14-11741
8
12 VDC+
12VDC- (Common)
Grounding Wire
P/N 14-11872
White Wire
(Common)
AC115V ± 10%
50 / 60 Hz
PE
4
INDICATORS
POWER 2P
20VAC 50/60Hz
N
7 6 5
L
10 9
Related Devices - 16P
>POM
<
Black Wire (Hot)
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Part #15-10596-30
Section 5b: (2) Optex i-One Sensors and (1) Holding Beam
5-15
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
NOISE
FILTER
Common
N/O
N/C
LOAD
TWO WAY
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
P/N 14-11875
KEY SWITCH
FOR U30
P/N 14-11876
FULL
OPEN
ORANGE
RED
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
WHITE
ROCKER SWITCH
EXTENSION HARNESS
FOR U30
P/N 14-11884
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
BLUE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
WHITE
U30 TERMINAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
GY RO TECH
NABCO
O
BC
11
1 12
7 0
4 32
ERROR
BA
62
H
! WARNING
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
Mode SW Usage
M0
MODE
M1
Open
Open
TWO WAY
Open
ONE WAY
Gnd
GndG
nd HOLD OPEN
Open
Gnd
NIGHT
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
FUNCTION [SLIDING DOOR]
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
12VDC-(Common)
12VDC+
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
BLUE
(TERM #4)
BLUE
(TERM #3)
U30 TERMINAL
P/N 14-11873
OPTEX OS-12C
Controller
TERM #1
TERM #1
BROWN &RED
(TERM 1 & 2)
OPTEX OS-12C
Controller
BROWN &RED
(TERM 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0541
OPTEX
OPTEX
HOLDING BEAM BREAKOUT BEAM
CONTROLLER
CONTROLLER
PT. NO.
PT. NO.
P/N 14-9710-03 P/N 14-9710-03
ACUSENSOR
EXTENSION
HARNESS
P/N 22-9267-00
RED
RED
WHITE
(TERM #5)
RED
(TERM #4)
EXTERIOR ACUSENSOR
P/N 148902
YELLOW
GRAY
BROWN
BLK/RED
WHITE
Power Harness (P/N 14-11874)
!
!
!
NABCO
GYRO TECH
MOTOR・12P
6B
61
POWER
ACUSENSOR
EXTENSION
HARNESS
P/N 22-9267-00
RED
RED
INTERIOR ACUSENSOR
P/N 148902
YELLOW
GRAY
BROWN
BLK
Main Harness For U30
P/N 24-11877
NA
U30 MICROPROCESSOR CONTROLLER
P/N 24-8901-30
Part #15-10596-30
REDUCED OPEN
RED
BLUE
WHITE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
BLUE
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROLLER LABEL
Mode Switch (See Mode SW Usage Shown Le)
Exterior Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
TB2
Auxiliary 120 VAC
Power Wires
(These wires are normally
coiled and ed up)
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
8
12 VDC+
12VDC- (Common)
Interior Acvaon
Holding Beam
Reduced Opening Switch
P/N 14-11872
TB1
ON/OFF
Power Switch
PE
Grounding Wire
(Common)
White Wire
AC115V ± 10%
50 / 60 Hz
MOTOR/OPERATOR
P/N 24-11327
INDICATORS
POWER SUPPLY
P/N 14-11741
RELATED DEVICES・16P
5-16
N
POWER・2P
20VAC 50/60Hz
L
7 6 5
Black Wire (Hot)
>POM
<
10 9
Related Devices - 16P
HANDY TERMINAL HARNESS
P/N 14-11837
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Rev. 1-10-14
Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam
Wiring Diagrams (Surface Applied Sliders)
Wiring Diagrams (Surface Applied Sliders)
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
Common
N/O
N/C
LOAD
TWO WAY
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
PN 14-11875
KEY SWITCH
FOR U30
PN 14-11876
FULL
OPEN
ORANGE
RED
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
WHITE
WHITE
WHITE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ROCKER SWITCH
EXTENSION HARNESS
FOR U30
PN 14-11884
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
BLUE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
WHITE
U30 TERMINAL
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
BLUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
GY RO TECH
NA
O
BC
7 0
11
1 12
MOTOR/OPERATOR
P/N 24-11327
INDICATORS
H
ERROR
BA
62
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
Mode SW Usage
M0
MODE
M1
Open
Open
TWO WAY
Open
ONE WAY
Gnd
GndG
nd HOLD OPEN
Open
Gnd
NIGHT
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
FUNCTION [SLIDING DOOR]
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
12VDC+
12VDC-(Common)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WHITE
GRAY
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
BLUE
(TERM #4)
BLUE
(TERM #3)
U30 TERMINAL
P/N 14-11873
TERM #1
TERM #1
BROWN &RED
(TERM 1 & 2)
DN 0542
OPTEX
OPTEX
HOLDING BEAM BREAKOUT BEAM
CONTROLLER
CONTROLLER
PT. NO.
PT. NO.
PN 14-9710-03
PN 14-9710-03
Optex OS-12C
Controller
BROWN &RED
(TERM 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Optex OS-12C
Controller
RED
TERM #4
WHITE
TERM #5
EXTERIOR OPTEX I-ONE
PN 14-10364-A
YELLOW
GRAY
YELLOW
GRAY
BROWN
BLK/RED
OPTEX
HARNESS
PN 12-13018
WHITE
GRAY
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
INTERIOR OPTEX I-ONE
PN 14-10364-A
YELLOW
GRAY
YELLOW
GRAY
BROWN
BLK
MAIN HARNESS FOR U30
P/N 24-11877
! WARNING
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
RELATED DEVICES・16P
U30 MICROPROCESSOR CONTROLLER
P/N 24-8901-30
!
!
!
NABCO
GYRO TECH
MOTOR・12P
6B
61
POWER
Power Harness P/N 14-11874
NABCO
Rev. 1-10-14
REDUCED OPEN
RED
BLUE
WHITE
BLUE
TB2
Auxiliary 120 VAC
Power Wires
(These wires are
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROLLER LABEL
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
12 VDC+
12VDC- (Common)
P/N 14-11872
PE
ON/OFF
Power Switch
TB1
NOISE
FILTER
8
Grounding Wire
(Common)
White Wire
AC115V ± 10%
50 / 60 Hz
32
4
N
POWER・2P
20VAC 50/60Hz
L
7 6 5
POWER SUPPLY
P/N 14-11741
10 9
Related Devices - 16P
>POM
<
Black Wire (Hot)
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Part #15-10596-30
Section 5d: (2) Optex i-One Sensors, (1) Holding Beam and (1) Breakout Beam
5-17
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
N/O
N/C
Common
LOAD
TWO WAY
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
PN 14-11875
KEY SWITCH
FOR U30
PN 14-11876
FULL
OPEN
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
WHITE
WHITE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WHITE
BLUE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
O
BC
7 0
11
1 12
MOTOR/OPERATOR
P/N 24-11327
INDICATORS
H
ERROR
BA
62
YELLOW
BLACK
BLUE
GREEN
On Remote Control Set: “F1” to “1”
If programming without the Remote: Parameter “13” to “1”
RED
BROWN
WHITE
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
WIZARD G3
PN 14-13036
GRAY
BROWN
BLK
MAIN HARNESS FOR U30
P/N 24-11877
! WARNING
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
Mode SW Usage
M0
MODE
M1
Open
Open
TWO WAY
Open
ONE WAY
Gnd
GndG
nd HOLD OPEN
Open
Gnd
NIGHT
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
FUNCTION [SLIDING DOOR]
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
12VDC+
12VDC-(Common)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RELATED DEVICES・16P
BLACK
BLUE
GREEN
YELLOW
GRAY
RED
BROWN
WHITE
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
U30 TERMINAL
P/N 14-11873
Optex OS-12C
Controller
TERM #1
BROWN &RED
(c IRc UIt 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0554
OPTEX
HOLDING BEAM
CONTROLLER
PT. NO.
PN 14-9710-03
WHITE
TERM #5
WIZARD G3
PN 14-13036
BROWN
BLK/RED
RED
TERM #4
U30 MICROPROCESSOR CONTROLLER
P/N 24-8901-30
!
!
!
NABCO
GYRO TECH
MOTOR・12P
6B
61
POWER
Power Harness P/N 14-11874
NA
White and Green wires from Sensor provide output for
ROCKER SWITCH
EXTENSION HARNESS
FOR U30
PN 14-11884
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
WHITE
U30 TERMINAL
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
BLUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
GY RO TECH
NABCO
Part #15-10596-30
ORANGE
RED
REDUCED OPEN
RED
BLUE
WHITE
TB2
Auxiliary 120 VAC
Power Wires
(These wires are
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROL LABEL
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
12 VDC+
12VDC- (Common)
P/N 14-11872
PE
ON/OFF
Power Switch
TB1
NOISE
FILTER
8
Grounding Wire
(Common)
White Wire
AC115V ± 10%
50 / 60 Hz
32
4
5-18
N
POWER・2P
20VAC 50/60Hz
L
7 6 5
POWER SUPPLY
P/N 14-11741
10 9
Related Devices - 16P
>POM
<
Black Wire (Hot)
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Rev. 1-10-14
Section 5e: (2) Wizard G3, and (1) Holding Beam
Wiring Diagrams (Surface Applied Sliders)
Wiring Diagrams (Surface Applied Sliders)
S1
PRESS
TO
RESET
RED INDICATES
POWER IS OFF
-CIRCUIT-BREAKER-
Common
N/O
N/C
LOAD
TWO WAY
HOLD OPEN
ONE WAY
NIGHT
OFF
ON
BACK SIDE OF
ROCKER SWITCH SHOWN
ROCKER SWITCH
FOR U30
PN 14-11875
KEY SWITCH
FOR U30
PN 14-11876
FULL
OPEN
ORANGE
RED
ORG/WHT
RED
GREEN
ORG/WHT
RED
ORANGE
WHITE
WHITE
WHITE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
BLUE
RED
RED
ORG/WHT
BLUE
GREEN
ORANGE
O
BC
11
1 12
7 0
MOTOR/OPERATOR
P/N 24-11327
INDICATORS
ERROR
BA
62
H
YELLOW
BLACK
BLUE
GREEN
On Remote Control Set: “F1” to “1”
If programming without the Remote: Parameter “13” to “1”
RED
BROWN
WHITE
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
WIZARD G3
PN 14-13036
GRAY
BROWN
BLK
MAIN HARNESS FOR U30
P/N 24-11877
! WARNING
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
Mode SW Usage
M0
MODE
M1
Open
Open
TWO WAY
Open
ONE WAY
Gnd
GndG
nd HOLD OPEN
Open
Gnd
NIGHT
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
FUNCTION [SLIDING DOOR]
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
12VDC+
12VDC-(Common)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RELATED DEVICES・16P
BLACK
BLUE
GREEN
YELLOW
GRAY
RED
BROWN
WHITE
ACUSENSOR
EXTENSION
HARNESS
PN 22-9267-00
RED
RED
BLUE
(TERM #4)
BLUE
(TERM #3)
U30 TERMINAL
P/N 14-11873
Optex OS-12C
Controller
TERM #1
TERM #1
BROWN &RED
(TERM 1 & 2)
Optex OS-12C
Controller
BROWN &RED
(TERM 1 & 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0555
OPTEX
OPTEX
HOLDING BEAM BREAKOUT BEAM
CONTROLLER
CONTROLLER
PT. NO.
PT. NO.
PN 14-9710-03
PN 14-9710-03
WHITE
TERM #5
WIZARD G3
PN 14-13036
BROWN
BLK/RED
RED
TERM #4
U30 MICROPROCESSOR CONTROLLER
P/N 24-8901-30
!
!
!
NABCO
GYRO TECH
MOTOR・12P
6B
61
POWER
Power Harness P/N 14-11874
NA
White and Green wires from Sensor provide output for
ROCKER SWITCH
EXTENSION HARNESS
FOR U30
PN 14-11884
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORG/WHT
BLK/RED
YELLOW
BLUE
GRN/WHT
WHITE
U30 TERMINAL
MAGNETIC POWER
DOWN SWITCH
P/N 22-9222
WHITE
BLUE
BLUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NABCO
GY RO TECH
NABCO
Rev. 1-10-14
REDUCED OPEN
RED
BLUE
WHITE
BLUE
TB2
Auxiliary 120 VAC
Power Wires
(These wires are
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
T1
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROLLER LABEL
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
12 VDC+
12VDC- (Common)
P/N 14-11872
PE
ON/OFF
Power Switch
TB1
NOISE
FILTER
8
Grounding Wire
(Common)
White Wire
AC115V ± 10%
50 / 60 Hz
32
4
N
POWER・2P
20VAC 50/60Hz
L
7 6 5
POWER SUPPLY
P/N 14-11741
10 9
Related Devices - 16P
>POM
<
Black Wire (Hot)
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Part #15-10596-30
Section 5f: (2) Wizard G3, (1) Holding Beam and (1) Breakout Beam
5-19
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
CHAPTER 6: INFRARED BEAM WIRING
Section 6a: Wiring (1) Holding Beam
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the
NABCO factory. This unit is shipped complete with the following:
►►Emitter
►►Receiver
►►Control Box
Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each
Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously
transmit across the Slide door opening. Interruption of the infrared light beam will switch the
White holding beam input wire to Red (Common). Thus causing the system to re-activate and
Hold Open until the interruption is cleared. Please Figure 6-1.
T1
NABCO
N
NA
PE
INDICATORS
4
3 2
1211
7 0
8
N/O
N/C
Common
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
U30 MICROPROCESSOR CONTROL LABEL
Related Devices - 16P
7 6 5
Mode Switch
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
1
10 9
Holding Beam
Reduced Opening Switch
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
! CAUTION
!
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
There are no user serviceable parts
inside.
!
To maintain warranty,repairs must be
made by authorized NABCO facilities.
HANDY TERMINAL 6P
No.
Microprocessor Controller
248901FUNCTION (SLIDING DOOR)
12VDC +
12VDC-(Common)
Interior Acvao n
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown le)
Exterio r Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT. A
OUT. B
OUT. C
OU T
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
WHITE
CONNECT
EACH TERMINAL
THE SAME
TERM #1
TERM #5
Yellow
Optex OS-12C
Controller
P/N 14-9710-03
Jacket Color
Braided Shield
TERM #6
BLUE
TERM #6
YELLOW
TERM #7
OTHER WIRES NOT SHOWN
FOR SIMPLICITY
DN 0547
GRAY
EMTR 1
6-20
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gn d
HOLD OPEN
Gn d
NIGH T
RED
TERM #13
GRAY
TERM #10
M0
Open
Gn d
Gn d
Open
BROWN & RED
CIRCUIT 1 & 2
U30 TERMINAL
P/N 14-11873
YELLOW
TERM #11
H
62
ERROR
S1
12 VDC+
12VDC- (Common)
GYRO TECH
6B
BA
MADE IN JAPAN
! WARNING
To protect against risk of Fire or electric shock,use only the
cerfied NABCO power supply.
!
NABCO
61
Nabtesco Corporation
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
PRESS
TO
RESET
MOTOR 12P
POWER
DS-1500
D24-113270
POWER 2P
20VAC 50/60Hz
RED INDICATES
POWER IS OFF
O
GYRO TECH
LOAD
-CIRCUIT-BREAKER-
BC
NABCO
TB2
TB1
>POM
<
NOISE
FILTER
L
AC115V ± 10%
50 / 60 Hz
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
MOTOR/OPERATOR
P/N 24-11327
RELATED DEVICES・16P
POWER SUPPLY
P/N 14-11741
BLUE
RCVR 1
Figure 6-1 (1) Holding Beam using Optex OS-12C Controller
Infrared Beam Wiring
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
Section 6b: Wiring (2) Holding Beams
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the
NABCO factory. This unit is shipped complete with the following:
►►Emitter
►►Receiver
►►Control Box
Both the Emitters and Receivers are flush mounted on both sides of the Slide door Frame or each
Jamb tube, directly across from each other (in pairs). Please see Figure 6-2 and Figure 6-3.
Emit
Rcvr
①
②
Emit
Rcvr
DN 0549
Figure 6-2 Transmission of Infrared Light Beams
A pulsed, infrared light beam is used to continuously transmit across the Slide door opening.
Interruption of the infrared light beam will switch the White holding beam input wire to Red
(Common). Thus causing the system to re-activate and Hold Open until the interruption is cleared.
TO
U30 CONTROLLER
TERMINAL
TO
AUXILIARY
POWER
SUPPLY
CONNECT
EACH TERMINAL
THE SAME
TERM #1
TERM #5
Yellow
Optex OS-12C
Controller
P/N 14-9710-03
YELLOW
TERM #13
BLUE
TERM #6
GRAY
TERM #12
YELLOW
TERM #11
GRAY
TERM #10
DN 0548
Infrared Beam Wiring
Braided Shield
TERM #13
YELLOW
TERM #9
Plasc Conductor
TERM #6
YELLOW
TERM #7
BLUE
TERM #8
Jacket Color
BLUE
RCVR 2
GRAY
EMTR 1
GRAY
EMTR 2
OTHER WIRES NOT SHOWN
FOR SIMPLICITY
BLUE
RCVR 1
Figure 6-3 (2) Holding Beams using Optex OS-12C Controller
6-21
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
Section 6c: Wiring Holding Beam for Breakout
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the
NABCO factory. This unit is shipped complete with the following:
►►Emitter
►►Receiver
►►Control Box
Both the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each
Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously
transmit across the Slide door opening. Interruption of the infrared light beam. By Breaking Out
a Slide door panel the Blue (BA) wire power down loop will be interrupted. Thus causing the
system to stop operating until the Slide door is repositioned and latched. Please see Figure 6-4.
T1
NABCO
N
NA
PE
INDICATORS
4
3 2
1211
7 0
8
N/O
N/C
Common
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
U30 MICROPROCESSOR CONTROL LABEL
Related Devices - 16P
7 6 5
Mode Switch
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
1
10 9
Holding Beam
Reduced Opening Switch
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Mode SW Usage
MODE
M1
Open
TWO WAY
Open
ONE WAY
Gn d
HOLD OPEN
Gn d
NIGH T
! CAUTION
!
Adjustments to the door can only be made
with the NABCO Handy Terminal.
Do not disassemble the control box.
There are no user serviceable parts
inside.
!
To maintain warranty,repairs must be
made by authorized NABCO facilities.
HANDY TERMINAL 6P
No.
Microprocessor Controller
248901FUNCTION (SLIDING DOOR)
12VDC +
12VDC-(Common)
Interior Acvao n
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown le)
Exterio r Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT. A
OUT. B
OUT. C
OU T
7
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RED
CONNECT
EACH TERMINAL
THE SAME
BLUE
TERM #5
TERM #1
Yellow
Optex OS-12C
Controller
P/N 14-9710-03
TERM #13
GRAY
TERM #10
M0
Open
Gn d
Gn d
Open
BROWN & RED
CIRCUIT 1 & 2
U30 TERMINAL
P/N 14-11873
YELLOW
TERM #11
H
62
ERROR
S1
12 VDC+
12VDC- (Common)
GYRO TECH
6B
BA
MADE IN JAPAN
! WARNING
To protect against risk of Fire or electric shock,use only the
cerfied NABCO power supply.
!
NABCO
61
Nabtesco Corporation
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
PRESS
TO
RESET
MOTOR 12P
POWER
DS-1500
D24-113270
POWER 2P
20VAC 50/60Hz
RED INDICATES
POWER IS OFF
O
GYRO TECH
LOAD
-CIRCUIT-BREAKER-
BC
NABCO
TB2
TB1
>POM
<
NOISE
FILTER
L
AC115V ± 10%
50 / 60 Hz
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
MOTOR/OPERATOR
P/N 24-11327
RELATED DEVICES・16P
POWER SUPPLY
P/N 14-11741
Jacket Color
Braided Shield
TERM #6
BLUE
TERM #6
YELLOW
TERM #7
OTHER WIRES NOT SHOWN
FOR SIMPLICITY
DN 0547
GRAY
EMTR 1
BLUE
RCVR 1
Figure 6-4 Breakout Beam using Optex OS-12C Controller
6-22
Infrared Beam Wiring
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
CHAPTER 7: ELECTRIC LOCK WIRING
Note:
Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic
hardware must be fitted to the Door Panels.
The Electric Lock is optional and can come in (1 of 2) configurations:
►►Fail Safe
•
Allows the Door Panel to be manually opened if power is turned Off.
•
Will not allow the Door Panal to be manually opened if power is turned Off.
►►Fail Secure
Electric Locks are used to prevent Door Panels from opening until they are activated by the U30
Microprocessor Control when it receives a signal from a:
►►Remote Switch
►►Transmitter
►►Activation Device on the face of the Door
Electric Locks are pre-installed at the NABCO Factory. Only the Strike mounted on the Header may
need to be adjusted.
Section 7a: Adjust the Strike.
1. Close Door Panel(s).
2. Go inside the Header. Loosen the Strike Mounting Bolts that is holding the Strike Bracket
secure to the Header.
3. Slide the Strike to align with the Latch Bolt in the fully closed position.
4. Tighten the Strike Mounting Bolts.
a. Do not overtighten.
Electric Lock Assembly
LATCHBOLT POSITION:
• BIPART UNITS
• LH SINGLE F.O.
• RH SINGLE F.S.
Dead Bolt Engaged with Electric Strike
Electric Strike
(Door in Full Closed Posion)
Slight Gap
(Between Strike Wall
and Dead Bolt)
Belt Clip
Terminal Strip
(Strike Side of Door)
Dead Bolt Assembly
LATCHBOLT POSITION:
• RH SINGLE F.O.
• LH SINGLE F.S.
Electric Lock Wiring
DN 1026
Figure 7-1 Adjust the Strike
7-23
GROUND HARNESS
P/N 14-11872
ON/OFF
POWER
SWITCH
S1
5
A
M
P
T1
AUXILIARY 120 VAC
POWER WIRES
(THESE WIRES NORMALLY
COILED AND TIED UP)
120 VAC
TB2
GRAY
OUTPUT TIMER
0 = (DO NOT USE)
1 = (DO NOT USE)
2 = (DO NOT USE)
3 = ELECTRIC STRIKE FUNCTION
OUTPUT: 0 = ELECTRIC STRIKE OUTPUT
FULLY CLOSED
OPENING
3 SEC
ON
CLOSING
FULL OPEN
ON
6
FULLY CLOSED
VIOLET
M<
>PO
GRY
VIO
BLK
WHT
110V
INDICATORS
H
ERROR
BA
62
WARNING
SYMBOL No.
9DC12V 1
7
2
61
3
6B
4
H
5
M0
6
M1
7
62
8
SQ
9
BA
10
SLS
11
N/O
OUT.A 12
N/C
OUT.B 13
Common OUT.C 14
OUT
15
7
16
RELATED DEVICES・16P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0551
FAIL SAFE LOCK ASSY.
P.N. 22-10522-04
FAIL SECURE LOCK ASSY.
P.N. 22-10522-03
FAIL
SAFE
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Mode Switch (see Mode SW Usage shown left)
POWER SUPPLY HARNESS
P/N 14-11874
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
Adjustments to the door can only be made
with the NABCO Handy Terminal.
CAUTION
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
Mode SW Usage
M0
M1
MODE
Open Open TWO WAY
FUNCTION [SLIDING DOOR]
Gnd Open ONE WAY 12VDC+
Gnd
Gnd HOLD OPEN 12VDC-(Common)
Open Gnd NIGHT
Interior Activation
Holding Beam
Reduced Opening Switch
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
OTHER WIRES NOT SHOWN
FOR SIMPLICITY
6
1
61
6B
GYRO TECH
MOTOR・12P
POWER
U30 CONTROL P/N 24-8901-30
Part #15-10596-30
OUTPUT TIMER
1.0 SEC
OUTPUT SIGNAL
OFF
ACTIVATION SIGNAL OFF
U30 ELECTRIC STRIKE OUTPUT SIGNAL
HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE
WIRING FOR ELECTRIC LOCK ONLY SHOWN
P/N 24-11877
SYMBOL No.
9DC12V 1
1
7
2
2
61
3
3
6B
4
4
5
H
5
M0
6
6
7
M1
7
Exterior Activation
62
8
8
Sequential Activation
SQ
9
9
Breakout Detector
10
BA
10
11
Sidelite Presence Sensor
SLS
11
Contact Output (Class2 Load only)
12
N/O
OUT.A
12
FAIL SECURE (OUT A)
30V(42.4Vpeak)max.
FAIL SAFE (OUT B)
13
N/C
OUT.B
13
5Amax.(0-20V), 3.2Amax.(20-30V)
14
14
Common OUT.C
Auxiliary Output (Open-Collector)
15
OUT
15
16
7
16
12VDC-COMMON
LABEL ON U30 CONTROL
TERMINAL ON U30 MAIN HARNESS
FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(COMMON)
INTERIOR ACTIVATION
HOLDING BEAM
REDUCED OPENING SWITCH
Mode Switch (see Mode SW Usage shown left)
GROUND LUG
SCREW TO HEADER
BLACK (HOT)
WHITE (COMMON)
AC115V ± 10%
50 / 60 Hz
TB1
ZN
R2
ZN
R1
NOISE
FILTER
TRANSFORMER
MOTOR/OPERATOR P/N 24-11327
MADE IN JAPAN
POWER SUPPLY P/N 14-11741
GYRO TECH
DS-150NA
(24-11327)
RELATED DEVICES - 16P
Note:
POWER・2P
20VAC 50/60Hz
0 7
8 9 10
11 12 1
7-24
2 34
HANDY TERMINAL HARNESS
P/N 14-11837
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Rev. 1-10-14
Section 7b: U30 with Fail Safe Electric Lock
Fail Safe Electric Lock only works in One Way mode or Night Mode.
Electric Lock Wiring
5
A
M
P
GROUND HARNESS
P/N 14-11872
ON/OFF
POWER
SWITCH
S1
T1
TB2
AUXILIARY 120 VAC
POWER WIRES
(THESE WIRES NORMALLY
COILED AND TIED UP)
120 VAC
TRANSFORMER
MOTOR/OPERATOR P/N 24-11327
OUTPUT TIMER
0 = (DO NOT USE)
1 = (DO NOT USE)
2 = (DO NOT USE)
3 = ELECTRIC STRIKE FUNCTION
OUTPUT: 0 = ELECTRIC STRIKE OUTPUT
OPENING
3 SEC
ON
FULLY CLOSED
OFF
ON
CLOSING
FULL OPEN
FULLY CLOSED
GRY
VIO
BLK
WHT
110V
6
1
61
ERROR
BA
62
H
6B
WARNING
CAUTION
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
INDICATORS
POWER SUPPLY HARNESS
P/N 14-11874
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
RELATED DEVICES・16P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0552
FAIL SECURE LOCK ASSY.
P.N. 22-10522-03
FAIL
SECURE
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Mode Switch (see Mode SW Usage shown left)
SYMBOL No.
9DC12V 1
7
2
61
3
6B
4
H
5
M0
6
M1
7
62
8
9
SQ
BA
10
SLS
11
N/O
OUT.A 12
N/C
OUT.B 13
Common OUT.C 14
OUT
15
7
16
Mode SW Usage
M0
M1
MODE
Open Open TWO WAY
FUNCTION [SLIDING DOOR]
Gnd Open ONE WAY 12VDC+
Gnd
Gnd HOLD OPEN 12VDC-(Common)
Open Gnd NIGHT
Interior Activation
Holding Beam
Reduced Opening Switch
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
GYRO TECH
MOTOR・12P
POWER
U30 CONTROL P/N 24-8901-30
Rev. 1-10-14
OUTPUT TIMER
1.0 SEC
OUTPUT SIGNAL
ACTIVATION SIGNAL
OFF
U30 ELECTRIC STRIKE OUTPUT SIGNAL
HANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE
WIRING FOR ELECTRIC LOCK ONLY SHOWN
P/N 24-11877
SYMBOL No.
9DC12V 1
1
7
2
2
61
3
3
6B
4
4
5
H
5
6
M0
6
Mode Switch (see Mode SW Usage shown left)
7
M1
7
Exterior Activation
8
62
8
Sequential Activation
SQ
9
9
Breakout Detector
10
BA
10
11
Sidelite Presence Sensor
SLS
11
GRAY (OUT A)
Contact Output (Class2 Load only)
12
N/O
OUT.A
12
30V(42.4Vpeak)max.
13
N/C
OUT.B
13
VIOLET
5Amax.(0-20V), 3.2Amax.(20-30V)
14
14
Common OUT.C
Auxiliary Output (Open-Collector)
15
OUT
15
16
7
16
12VDC-COMMON
LABEL ON U30 CONTROL
TERMINAL ON U30 MAIN HARNESS
FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(COMMON)
INTERIOR ACTIVATION
HOLDING BEAM
REDUCED OPENING SWITCH
GROUND LUG
SCREW TO HEADER
BLACK (HOT)
WHITE (COMMON)
AC115V ± 10%
50 / 60 Hz
TB1
R1
R2
ZN
ZN
NOISE
FILTER
POWER SUPPLY P/N 14-11741
MADE IN JAPAN
DS-150NA
GYRO TECH
(24-11327)
Electric Lock Wiring
POWER・2P
20VAC 50/60Hz
Note:
RELATED DEVICES - 16P
HANDY TERMINAL HARNESS
P/N 14-11837
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Part #15-10596-30
Section 7c: U30 with Fail Secure Electric Lock
Fail Secure Electric Lock only works in One Way mode or Night Mode.
7-25
7-26
U-19 & Earlier
BIPART SLIDE DOOR
Motor/Operator
11 11/16
U-19 & Earlier
Belt Clip Top
Belt Clip Top
8 5/16
Relay
Motor/Operator
Belt Bracket
Relay
Belt Clip Boom
Terminal Strip
SINGLE SLIDE DOOR; RHFS, LHFO
U-19 & Earlier
Belt Bracket
11 11/16
DN 0534
Note:
SINGLE SLIDE DOOR; LHFS, RHFO
Motor/Operator
Belt Clip Top
Terminal Strip
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
Section 7d: U30 with Magnetic Lock
Magnetic Lock only works in One Way mode or Night Mode.
Electric Lock Wiring
Custom Wiring
RED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RELATED DEVICES - 16P
Contact 2
Contact 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ORANGE
RED
ORG/WHT
BLUE
GREEN
ORANGE
ROCKER SWITCH
EXTENSION HARNESS
FOR U30
PT. 14-11884-10
ORG/WHT
BLUE
GREEN
ORANGE
ORG/WHT
RED
TERMINAL ON U30 CONTROL
P/N 14-11873
CUT ROCKER SWITCH
EXTENSION HARNESS
AND SPLICE AS SHOWN
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
SYMBOL No.
RED
ORG/WHT
BLUE
GREEN
ORANGE
Hold Open
Night Mode
C losed
C losed
Open
Open
One Way Mode
(Exit Only)
Contact 1
Mode
Two Way (Auto)
Closed
Open
Closed
Open
Contact 2
NOTES:
1. BLUE WIRE MUST BE CONNETED TO
RED FOR DOOR TO OPERATE.
2. IT IS RECOMENDED THAT PART NUMBER
14-11884-10 BE USED FOR THESE
MODIFICATIONS. THIS WOULD ALLOW
CHANGES TO, OR REVERSAL OF
MODIFICATIONS TO BE MADE EASIER.
3. OTHER WIRES NOT SHOWN FOR SIMPLICITY
4. REMOTE SWITCH MUST BE DRY CONTACTS
(NO VOLTAGE)
5. CAP OFF ALL UNUSED WIRES
Rev. 1-10-14
DN 0553
DN 0553
From DN 0291
N/O
N/C
Common
LABEL ON U30 CONTROL
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-COMMON
Mode Switch (see Mode SW Usage shown left)
FUNCTION [SLIDING DOOR]
12VDC+
12VDC-(COMMON)
INTERIOR ACTIVATION
HOLDING BEAM
REDUCED OPENING SWITCH
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Part #15-10596-30
CHAPTER 8: CUSTOM WIRING
Section 8a: U30 Configured for Remote Control of Modes
8-27
S1
PRESS
TO
RESET
TB2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Auxiliary 120 VAC
Power Wires
(These wires are
normally coiled
and tied up)
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
ENTRANCES, INC.
14-11741
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROL LABEL
Common
N/O
N/C
LOAD
U30 TERMINAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RED
GRN/WHT
MADE IN JAPAN
Nabtesco Corporation
DS-1500
D24-113270
GY RO TECH
NABCO
NABCO
NA
O
BC
4 32
11
1 12
7 0
SIDELITE ACUSENSOR
P/N 14-8902
ERROR
BA
62
H
6B
61
POWER
! WARNING
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Do not disassemble the control box.
There are no user serviceable parts
inside.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
! CAUTION
Mode SW Usage
M0
MODE
M1
Open
Open
TWO WAY
Open
ONE WAY
Gnd
GndG
nd HOLD OPEN
Open
Gnd
NIGHT
To protect against risk of fire or electric shock,use only the
certified NABCO power supply.
Exterior Activation
Sequential Activation
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V(42.4Vpeak)max.
5Amax.(0-20V), 3.2Amax.(20-30V)
Auxiliary Output (Open-Collector)
12VDC-(Common)
Interior Activation
Holding Beam
Reduced Opening Switch
Mode Switch (see Mode SW Usage shown left)
12VDC-(Common)
FUNCTION [SLIDING DOOR]
CUT ACUSENSOR
EXTENSION HARNESS
AND SPLICE AS SHOWN
P/N 14-11874
N/O
N/C
Common
SYMBOL
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
OUT.A
OUT.B
OUT.C
OUT
7
HANDY TERMINAL・6P
Microprocessor Controller
248901-
No.
12VDC+
Power Harness
!
!
!
NABCO
GYRO TECH
MOTOR・12P
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
RELATED DEVICES・16P
U30 TERMINAL
P/N 24-11877
SIDELITE ACUSENSOR
P/N 14-8902
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Part #15-10596-30
DN 0546
-CIRCUIT-BREAKERRED INDICATES
POWER IS OFF
ON/OFF
Power Switch
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
Mode Switch
Holding Beam
Reduced Opening Switch
12 VDC+
12VDC- (Common)
P/N 14-11872
Grounding Wire
(Common)
White Wire
TB1
T1
Related Devices - 16P
NOISE
FILTER
GREEN
AC115V ± 10%
50 / 60 Hz
BLACK
RED
INDICATORS
POWER・2P
20VAC 50/60Hz
MOTOR/OPERATOR
P/N 24-11327
GREEN
POWER SUPPLY
P/N 14-11741
8
WHITE
PE
BLACK
8-28
N
7 6 5
L
RED
10 9
WHITE
>POM
<
Black Wire (Hot)
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Rev. 1-10-14
Section 8b: Sidelite Sensors
Custom Wiring
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
Section 8c: U30 Using Card Readers or other Secure Activation Devices
KEY PAD OR CARD READER ON
SECURE SIDE OF DOOR
(N.O. - DRY CONTACTS)
1. “FUNCTION 13” UNDER “EXTRA FUNCTIONS” MUST BE SET TO “3”.
2. “FUNCTION 13” SET TO 3 ENABLES THE “SLS” INPUT TO ACTIVATE THE
DOOR REGARDLESS OF THE MODE (AUTO, ONE WAY, NIGHT).
3. DEVICE MUST PROVIDE NORMALLY OPEN, DRY CONTACTS (NO VOLTAGE).
4. OTHER WIRES NOT SHOWN FOR SIMPLICITY.
N.O.
12 VDC+
12VDC- (Common)
Interior Acvaon
Holding Beam
Reduced Opening Switch
Mode Switch (See Mode SW Usage Shown LeŠ)
Exterior Acvaon
Sequenal Acvaon
Breakout Detector
Sidelite Presence Sensor
Contact Output (Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
12VDC Common
N/O
N/C
Common
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
U30 MICROPROCESSOR CONTROL LABEL
P/N 24-8901-30
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Related Devices - 16P
COM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
TERM #11
U30 TERMINAL
P/N 24-11877
NONžSECURE ACTIVATION DEVICES SUCH AS PUSH
PLATES CAN ALSO BE CONNECTED TO THE INTERIOR
ŸTERMINAL 3 AND COMMON¡ OR EXTERIOR
ŸTERMINAL 8 AND COMMON¡ ACTIVATION INPUTS.
THIS WILL ALLOW THEM TO BE TURNED OFF OR ON
BY USING THE MODE SWITCHES
ŸTWO WAY, ONE WAY, NIGHT¡
Custom Wiring
TERM #2
DN 0545
8-29
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
CHAPTER 9: TROUBLESHOOTING
Trouble
Slide door panicked open.
System fails to shut down.
Slide door does not open
when power is applied.
Do Not manually shut door.
Handy Terminal screen does
not change.
Door opens and closes
very slowly.
Slide doors do not
Open completely.
Reset the system back to
NABCO Factory settings
9-30
Action
Check wiring on the magnetic power down switches. Blue (BA) circuit must open
for system to shut down.
XX Confirm the Breakout Panel(s) is closed completely.
XX Confirm Blue (BA) circuit is not open.
• Verification can be done by observing Green (BA) status LED on U30
Controller. If LED in ON, the circuit is Open, and the unit will not operate.
XX Check that the power down magnet in the top rail of the Breakout panel is
installed and aligned with the magnetic power down switch in the bottom of
the Header.
XX Confirm Rocker Switch is set to ON not OFF.
XX Confirm the Breakout Panel(s) is closed completely.
XX Confirm Blue (BA) circuit is not open.
• Verification can be done by observing Green (BA) status LED on U30
Controller. If LED in ON, the circuit is Open, and the unit will not operate.
XX Check that the power down magnet in the top rail of the Breakout panel is
installed and aligned with the magnetic power down switch in the bottom of
the Header.
XX Confirm Rocker Switch is set to ON not OFF.
XX Check and clear error codes with Handy Terminal.
XX If Handy Terminal is not available, cycling the power will make the control
resume normal operation.
XX Look for obstructions in the track as well as inside the Header.
• Check to ensure that Belt Clips are not hitting something.
XX Check that the Mode Switch on the panel is not in “Reduced Opening” mode.
Also verify that the Green (H) status LED on the U30 Controller is not lit. If this
LED is ON, it indicates that there is a signal on the “Reduced Opening” circuit
(Green “H” is being shorted to Red 7)
XX Use the Handy Terminal and reintialize the system.
XX Plug in Handy Terminal and wait for the Slide door to Close.
1. At “Swing/Slide Stroke?” enter YES.
2. At “Swing Door Y or N?” enter YES (even though you have a slide door).
a. “Swing Door Y or N?” enter NO.
b. System will now intialize as a Slide door to NABCO Factory settings.
3. Set Slide door Stroke according to prompts the Handy Terminal displays.
Troubleshooting
www.NabcoEntrances.com
Electrical Installation Manual U-30 Control
Rev. 1-10-14
Part #15-10596-30
CHAPTER 10: RETURN POLICY
Note:
Please call Customer Service if the Return Material tag number is not known at 1-888-679-3319.
A Return Material tag is used for:
►►In Warranty and Out of Warranty materials.
►►Repair and Return.
►►Return for Credit Transactions.
NABCO ENTRANCES Standard Term & Conditions and Warranty govern all returned items. These
are provided in detail in the Terms & Conditions section of NABCO ENTRANCES Price Book. If you
have any questions on warranty or the use of the RMA tag, please call NABCO’s Customer Service
Department toll free at 1-888-679-3319.
Section 10a: How to Print and Fill out a Return Material Tag
1. Go to the NABCO Website at http://nabcoentrances.com/
a. The NABCO homepage will be displayed.
2. Go to the left hand column. Under “Quick Links” click on:
RMA LABELS
3. Enter the RMA number. Click on:
RMA LOOKUP
4. Fill out all necessary contact information. Click on:
GENERATE A LABEL
a. An assigned RMA tag will be displayed.
5. Print the assigned RMA tag.
a. The RMA tag is printed in triplicate.
6. Record following information on the tag:
XX
Serial No. or Part No.
XX
Part Name (description)
XX
Return Policy
•
Serial numbers for electronic components are stamped, engraved or printed on
stickers and located on the component. Non-electrical parts usually do not have
serial numbers.
Expiration Date
•
Expiration dates for electronic components are stamped, engraved or printed on
stickers and located on the component. Non-electrical parts usually do not have
expiration dates. For “Warranty claims of non-electrical parts”, please include a
photocopy of the original NABCO invoice the part was purchased on.
10-31
Electrical Installation Manual U-30 Control
www.NabcoEntrances.com
Part #15-10596-30
Rev. 1-10-14
XX
Date Returned
XX
Requested Repair and Return Action
XX
XX
XX
XX
•
The date that the malfunctioning Unit or Part is returned to NABCO Entrances INC.
•
Specify in/out warranty for R&R, Exchange, or in warranty for credit. For requests for
credits, please write the number of the invoice you want credited.
Distributor Name
Date of Installation
Installed at Job
Describe part problem
7. Attach an RMA tag to each malfunctioning Unit or Part that is returned to the NABCO factory.
8. The RMA tag is printed in triplicate. Please keep (top) copy of the tag.
9. Send remaining (2) copies along with each malfunctioning Unit or Part to the attention of:
REPAIR AND RETURN DEPARTMENT AT NABCO ENTRANCES.
a. Please remember to package the malfunctioning Unit and/or Parts properly.
10. Ship the parts freight prepaid.
Note:
10-32
a. Collect shipments will be refused.
All return inquiries must be accompanied with the RMA tag number associated with the
malfunctioning Unit and/or part.
Return Policy