Instruments - American Orthodontics
Transcription
Instruments - American Orthodontics
225 Instruments 800.558.7687 | 920.457.5051 Instruments 226 Enduring Excellence It is not enough for a cutter to be sharp or a bender to form wire. They must function consistently over time. American Orthodontics delivers on this promise with its premium line of Omega Precision Instruments. Pleasing to the Eye and Hand Omega’s hand-polished, satin finish compliments the appearance of any modern office, while also reducing glare. Its contemporary, sleek design fits the hand comfortably and performs effortlessly. Ωmega ® Precision Instruments www.americanortho.com Ωmega 227 Instruments ® Precision Instruments Ten Year Warranty A warranty this strong comes from a commitment to craftsmanship, which begins with quality materials and ends with precision manufacturing. Omega Instruments are guaranteed to resist corrosion and breakage for 10 years. Every Omega instrument is made from our TM uniquely formed DuraSteel forgings, providing excellence that endures the harsh environment of cleaning and sterilization. Each instrument is designed for a particular purpose, so Omega forging alloys are blended for that purpose. For example, cutters are designed to flex in the handle more than benders to provide a more comfortable shock absorber effect. The inserts for Omega cutters integrate seamlessly into the head of the cutter, repelling corroding elements and offering the perfect balance between sharpness and durability. Precision Manufacturing Precision manufacturing can only be appreciated when handling different styles of Omega Instruments. Consistency in the functioning of the instrument as well as its fit and feel in the hand are what separates precision instruments from the rest of the field. Instead of spending time to find your favorite instrument, you can pick the one closest to you and feel confident that it fits your hand just the way you like it. All Omega Precision Instruments are laser marked for part identification and maximum wire capacity. Choosing the right steel Omega benders benefit from a slightly harder TM DuraSteel forging than Omega cutters. A harder handle offers firmer control and less flex than Omega cutters while a softer handle allows for more shock absorption when cutting wire. Omega cutters have proprietary highgrade stainless steel inserts for the cutting tips. These tips hold an excellent cutting edge and have superior corrosion resistance. The harder material also increases the endurance of the pliers’ wire contacting areas. RHC RHC60 RHC 51 or more 40 CutterBender Cutter handleshandles tips Rockwell Hardness - RHC 800.558.7687 | 920.457.5051 228 Ωmega Instruments ® Precision Instruments CUTTERS 001-016E Distal End Cutter Safely cuts and securely holds distal ends of arch wire. Precise cutting edges and tip angle allow arch wires to be cut close to the distal end of tubes. Hardened inserted tips provide longer wear. Maximum cutting capacity is .021 x .025 wire. 001-016LE Distal End Cutter - long handle Provides extended reach to the posterior regions of the mouth. Maximum cutting capacity is .021 x .025 wire. 001-016ME Distal End Cutter - slim head Long, slim beaks make precise cutting and holding of arch wires effortless, even in hard to reach areas. Standard handle length. Maximum cutting capacity is .021 x .025 wire. 001-016MLE Distal End Cutter - slim head and long handle Features a long, slim beak for precision cutting and holding of arch wires as well as an extended reach to the posterior regions. 001-016E Maximum cutting capacity is .021 x .025 wire. 001-016LE 001-016ME 001-016MLE Omega Distal End Cutters are not recommended for multi-strand wires. www.americanortho.com Handle comparison: Long handle option makes hard to reach areas more accessible. Ωmega 229 ® CUTTERS 001-001E Pin and Ligature Cutter Super sharp, diamond-honed edges cut cleanly, leaving no ragged edges. The workhorse of pin and ligature cutters. Maximum cutting capacity is .015 soft wire. 001-002E Mini Pin and Ligature Cutter Finer tips than model 001-001E, for easier access to tight areas. Cuts even the smallest soft wire, ligatures, pins, and elastomerics. Maximum cutting capacity is .012 soft wire. 001-003E 001-001E Micro Pin and Ligature Cutter The finest tips available for cutting ligature wire, elastomerics, and other soft wire auxiliaries where access is at a premium. 001-002E Maximum cutting capacity is .012 soft wire. 001-003E 007-001E Hard Wire Cutter The most durable cutter available. Capable of cutting any size pin, ligature, or wire up to .022 x .028. 007-001E 800.558.7687 | 920.457.5051 Instruments Precision Instruments 230 Ωmega Instruments ® Precision Instruments WIRE BENDING PLIERS 001-300E NiTi Tie Back Pliers Revolutionary pliers tie back NiTi wire intraorally with no heat required. The precision tips also allow for other types of bends previously only possible in stainless steel. Not recommended for round wire. Maximum wire capacity is .021 x .025. 001-139E Bird Beak Pliers Features a cone shaped beak opposed by a pyramid shaped beak. Tips are angled and all working edges are beveled to prevent scoring or nicking of the wire. Designed to work with round wire up to .030 diameter. 001-142E Tapered Bird Beak Pliers Offers both the strength and durability of a traditional bird beak as well as the flexibility to bend light wires. Designed to work with wire up to .030 diameter. 001-300E 001-139E 001-142E www.americanortho.com Ωmega 231 ® WIRE BENDING PLIERS 001-140E Light Wire Pliers Longer, more gradually tapered beaks than bird beak pliers. A round beak with a cone tip of .025” and a pyramid tip with 9° angle ground on the sides to allow for wire springback. Slender beaks make it easier to bend small diameter loops. The working edges are carefully beveled to prevent wire scoring. 001-140E Maximum wire capacity is .020. 001-810SE Tweed Style Rectangular Arch Bending Pliers 001-810SE Ideal for bending square and rectangular wire. Edges are radiused and hardened to prevent wire scoring and to preserve a smooth contact area with the wire. Maximum wire capacity is .0215 x .028. 001-200E Three Jaw Pliers Features precision-aligned tips for consistent bends and gradual taper for delicate bends. One piece construction of the double tip ensures strength and eliminates flaring. 001-200E Maximum wire capacity is .030. 001-201E Three Jaw NiTi Pliers Gradual tapering for delicate bends. One piece construction of double tip for strength. Uniquely designed to form and contour nickel titanium wire, overcoming its shape memory at the point of contact. 001-201E Maximum wire capacity is .020. 800.558.7687 | 920.457.5051 Instruments Precision Instruments 232 Ωmega Instruments ® Precision Instruments UTILITY PLIERS General utility pliers provide easy access to lingual and posterior areas. Carefully tapered and serrated beaks fit easily between brackets and are slightly rounded for safety and comfort. 001-158E Weingart Pliers 001-158LE Weingart Pliers - long handle 001-158SE Weingart Pliers - slim beaks and standard length handle. 001-158LE 001-158E Handle comparison: Long handle option makes hardto-reach areas more accessible. 001-158SE 001-158E 001-158LE www.americanortho.com Ωmega 233 ® DEBONDING PLIERS 001-346E 001-343E Direct Bond Metal Bracket Remover These pliers are specially designed for quick and comfortable removal of direct bond metal brackets. Dual chisel tips wedge between the enamel/adhesive interface. May be used mesial-distal or occlusal-gingival. 001-346E 001-343E Radiance® Bracket Debonding Pliers This instrument provides a unique option for debonding Radiance clear sapphire brackets. The tips are designed to grasp each Radiance bracket under the tie wing rather than making contact at the enamel/adhesive interface. These pliers are pre-adjusted with set screws to ensure that an optimal amount of pressure is applied to the bracket when the handles are squeezed together. To debond Radiance brackets, place the opposing tips of the pliers occlusal/gingival under the tie wings while applying constant pressure to the handles of the pliers. Gently move the angle of the instrument to the occlusal or gingival of the tooth with increasing force until the Radiance bracket releases from the tooth. 001-408 Replacement tips (Qty. 2 with wrench) Tips are easily replaced and should be disinfected prior to use. 001-301E Wedge tips between bracket base and tooth either mesial/ distal or occlusal/gingival. Place opposing tips occlusal/gingival under the tie wings and gently angle instrument in one direction, either occlusally or gingivally. Ceramic Bracket Debonding Pliers Also known as Sushi pliers, this unique debonding instrument is specially designed for removing ceramic brackets. Only one edge of each blade is sharpened to ensure optimal fit along the enamel/adhesive interface. Opposing edges are parallel when the debonding instrument is open 3 mm, which is the average width of a ceramic bracket. Leave arch wires and ligatures in place during debonding. Remove adhesive flash from the mesial and distal edges of the bracket. Place debonding blades along the enamel/adhesive interface. Squeeze handles slowly until bracket releases from the tooth. 001-301E Debonding blades are parallel when placed along mesial and distal sides of ceramic brackets, ensuring consistent debonding. Remove adhesive flash. Place tips mesial/distal along interface between tooth and adhesive and squeeze slowly. 800.558.7687 | 920.457.5051 Instruments Precision Instruments 234 Ωmega Instruments ® Precision Instruments DEBONDING PLIERS Debonding pliers provide easy access to lingual and posterior areas. 001-347LE Posterior Band Remover - with long beaks Ideal for posterior band removal. The padded tip rests on the occlusal of the molar cusp. Designed for better accessibility to distal area. 3/16“ diameter heat sterilizable pad comes standard with the instrument. 012-076 3/16” Replacement pads (Qty. 2) 001-302 Lingual Debonding Pliers 001-347LE Designed to remove lingual bonds such as lingual brackets and bite blocks. The unique design allows for easy and comfortable debonding. 001-344RTE Adhesive Removing Pliers Designed to easily remove adhesive remnants after debonding appliances. The stainless steel tip glides across the surface of the tooth using the counterforce of the interchangeable plastic pad to safely remove excess bonding material from enamel. 1/4” diameter heat sterilizable pad comes standard with instrument. 012-077 001-407 1/4” Replacement pads (Qty. 2) Replacement metal tip insert (Qty. 1 with wrench) 001-344RTE Example of easy removal of lingual bite blocks. 001-302 www.americanortho.com 235 INSTRUMENTS Produced with state-of-the-art CNC (Computerized Numerical Control) manufacturing equipment, Masterline instruments boast unmatched consistency, strength, and durability. Multiple instruments are shaped simultaneously, so each has a consistent feel, weight, and size. This unmatched consistency is particularly important to clinicians who cycle several sets of instruments through the sterilization process every day. Unlike instruments produced with traditional equipment, Masterline instruments have uniquely radiused corners to eliminate potential stress points, significantly reducing the risk of fracture. Special high grade stainless steel forgings maximize corrosion resistance and enhance durability, greatly increasing longevity and ensuring smooth, easy function. The precise computerized milling process allows unprecedented tolerances - up to four digits. This precision virtually eliminates binding, avoids excessive play in the joint, and preserves the integrity of the working surface. Masterline instruments are hand buffed to a smooth, mirror finish, making instrument cleanup easy and further improving corrosion resistance. Masterline instruments are available in a wide variety of the most popular designs and configurations. Their unique qualities and features have established new standards for precision orthodontic instruments. Compare the hinge area of the Masterline (upper) and that of a competitive instrument. Masterline's radiused hinge corners eliminate stress points. Five Year Warranty American Orthodontics warrants its Masterline instruments to be free of defects in material and workmanship for five years. Misuse, abuse, or failure to properly maintain or care for the instrument will void warranty. Cutting instruments should be reconditioned every 6 - 9 months. Warranty does not cover routine maintenance, sharpening, or reconditioning. 800.558.7687 | 920.457.5051 Instruments MasterLine TM Instruments 236 MasterLine TM CUTTERS 001-016 Safety Shear and Hold Distal End Cutter Safely cuts and securely holds distal ends of arch wires. Precise cutting edges and tip angle allow arch wires to be cut close to the distal end of buccal tubes. Hardened inserted tips provide longer wear. Maximum cutting capacity: .0215 x .028 stainless steel. Not recommended for nickel titanium wire. 001-016L Safety Shear and Hold Distal End Cutter, Long Handle Long handle model facilitates access to hard-to-reach areas and provides extra cutting leverage - approximately .5”/1.5 cm longer. Precise cutting edges and tip angle allow arch wires to be cut close to the distal end of buccal tubes. Hardened inserted tips provide longer wear. Maximum cutting capacity: .0215 x .028 stainless steel. Not recommended for nickel titanium wire. 001-016T Small Wire Safety Shear and Hold Distal End Cutter Modified tip designed for cutting and consistently holding high tensile stainless steel wires (up to .018). Recommended for cutting all sizes of nickel titanium wire. Maximum cutting capacity: .018 stainless steel wire. All sizes nickel titanium wire. 001-010 Distal End Cutter Allows arch wire to be cut almost flush with the distal end of buccal tubes eliminating potential irritation to patients. Maximum cutting capacity: .0215 x .028 stainless steel. 001-001 Standard Pin and Ligature Cutter Super sharp, diamond-honed edges cut cleanly, leaving no ragged edges to grind. The “workhorse” of pin and ligature cutters. Maximum cutting capacity: .015 soft wire. 001-002 Mini Pin and Ligature Cutter Finer tips than model 001-001, for easier access to tight areas. Cuts even the smallest soft wire, ligatures, pins, and elastomerics. A precise, yet sturdy instrument. Maximum cutting capacity: .012 soft wire. 001-016 001-016L 001-001 001-016T 001-010 www.americanortho.com 001-002 CUTTERS 007-001 Hard Wire Cutter Capable of cutting any size pin, ligature, or wire up to, and including, .0215 x .028. Inserted tips, made from specially hardened high-speed tool steel. The most durable cutter available. Maximum cutting capacity: .0215 x .028 001-000HC Angled 15° Hard Wire Cutter - chrome Features a 15° cutting angle for easy access and better visibility. Particularly useful in cramped posterior areas. Maximum cutting capacity: .0215 x .028 001-000HW Angled 15° Hard Wire Cutter - anodized black Features a 15° cutting angle for easy access and better visibility. Particularly useful in cramped posterior areas. Black color distinguishes hard wire cutter from pin and ligature cutters with smaller wire cutting capacity. Maximum cutting capacity: .0215 x .028 001-006 45° Ligature Cutter Allows easier access under tie wings to clip ligature wires. Excellent for use in posterior areas. Minimizes the risk of cheek impingement. Maximum cutting capacity: .012 soft wire. 001-026 Band Slitting Instrument Shear cuts upper and lower bands with a minimum of patient discomfort by gripping the incisal and gingival edges of the band, towards the interproximal, adjacent to the bracket. May also be used to remove direct bond attachments. Caution: avoid bracket flange and tie wing. 007-001 001-026 001-000HC 001-000HW 001-006 800.558.7687 | 920.457.5051 237 Instruments MasterLine TM Instruments 238 MasterLine TM WIRE BENDING PLIERS 001-E140 Light Wire Pliers Longer, more gradually tapered beaks than bird beak pliers (001-E139). A round beak with a cone tip of .025 and a pyramid tip with 9° angle ground on the sides to allow for wire springback. Slender beaks make it easier to bend small diameter loops. The working edges are carefully beveled to prevent wire scoring. 001-E140 Maximum wire capacity: .020 001-E141 Super Looper Light Wire Pliers - Begg Style Features two grooves at the tip for bending identical vertical loops and helices. The utility groove at the back is for closing loops. Accommodates round, square, and rectangular wire up to .020 diameter. Maximum wire capacity: .020 001-E141 001-E350 Loop Forming Pliers - Tweed Style Capable of making “Bull” and helical closing loops in square and rectangular wire. Round beak has three step sections of .045, .060, and .075 in diameter. Cylindrical beak is electro-etched to prevent wire slippage. Concave beak has slight parallel serrations to hold wire at 90° angle while forming loops. Replacement tips with Allen wrench available. Maximum wire capacity: .0215 x .028 001-400 2 replacement tips and wrench 001-E350 001-E352 Omega Loop Forming Pliers - Tweed Style A concave beak allows for easy, uniform Omega loops in square and rectangular wire. Round beak has three sections, each is .090 in length and .045, .060, .075 in diameter. Replacement tips with Allen wrench available. 001-E352 Maximum wire capacity: .0215 x .028 001-400 2 replacement tips and wrench 001-E139 001-E139 Bird Beak Pliers Features a “cone” shaped .025 beak, opposed by a “pyramid” shaped beak. Tips are angled at 9° to allow for wire springback. All working edges are beveled to prevent scoring or nicking of the wire. Designed to work with round wire up to .030 diameter. Maximum wire capacity: .030 www.americanortho.com WIRE BENDING PLIERS 001-051 V-Bending Pliers Used for putting permanent centerline, anti-shift gable bends, and positive stops anywhere in nickel titanium arches. 001-051 001-E410 Lingual Arch Forming Pliers These pliers are designed to form terminal double-back and triple-back bends in either .030 or .036 wire for inserting in horizontal lingual sheaths. The blade width is the same .140 width of a lingual sheath. 001-E410 001-E810S Rectangular Arch Forming Pliers - Tweed style short beaks Ideal for bending square and rectangular wire up to .0215 x .028. Edges are radiused and hardened to prevent wire scoring and to preserve a smooth contact area with the wire. Blades are parallel when opened to .020 to ensure accurate 90° bends. Maximum wire capacity: .0215 x .028 001-E810S 001-E200 Three Jaw Straight Pliers Features precision-aligned tips for consistent bends and gradual taper for delicate bends. One piece construction of the double tip ensures strength and eliminates flaring. Maximum wire capacity: .0215 x .028 001-E200 001-E355 001-E355 Jarabak Pliers These pliers are ideal for precise bending of lighter wires. Matching grooves in both beaks allow for accurate bending and closing of loops. Tips are serrated for sure grip. 800.558.7687 | 920.457.5051 239 Instruments MasterLine TM Instruments 240 MasterLine TM WIRE BENDING PLIERS 001-E110 How Style Straight Utility Pliers Ideal for grasping all types of auxiliary attachments for fast and safe insertion. The center line of the 3/32 diameter pads coincides with the pliers’ axis of rotation. Matched serrated tips hold wire at any convenient working angle. Beaks are rounded for patient safety and comfort. These Weingart pliers show the difference between a standard Weingart and a Weingart with the longer handles. 001-E111 How Style Offset Utility Pliers Incorporates the same features as the straight How pliers, but tips have a 45° angle for easy access to posterior intraoral areas. 001-E113 Band Seating Pliers Designed to firmly grip bracket tie wings to aid in band seating. Capable of fitting between the smallest twin bracket, the square tips and strong beaks of these pliers allow for maximum gripping without scoring bracket wings. 001-E8011 Weingart 45°Utility Pliers Difficult to reach areas are made more accessible with the 45° angled tips. Serrated pads hold wires securely at a convenient angle. Tapered beaks are slightly rounded for safety and comfort. 001-E158 Weingart Pliers 001-E158L Weingart Pliers - long handle General utility pliers provides easy access to lingual and posterior areas. Pointed, serrated pads are precision matched near center of rotation for better balance and sure grip. Carefully tapered beaks fit easily between brackets and are slightly rounded for safety and comfort. 001-E158 001-E8011 001-E111 001-E110 www.americanortho.com 001-E113 WIRE BENDING PLIERS Instruments 100-302 Nance Loop Pliers Allows precision loop forming in rectangular wires. Both edges of this pliers' thin beaks are fully radiused and stepped at 3 mm, 4 mm, 5 mm, and 6 mm for forming various size loops. 001-207 Optical Style Pliers Ideal forming pliers for helical closing loops and arch adjustments. Thin concave beak ensures precise wire bends without nicking wire. 100-550 Nance Tie Back Pliers These multipurpose specialty pliers are used for easily forming stops, tie backs, or Adams clasps for retainers. 100-208 Band Contouring Pliers Ideal for reshaping molar bands and forming arch wire bows. 100-302 010-145 Hollow Chop Pliers This contouring pliers’ mated concave and convex jaws are useful in reshaping arch wires and forming palatal arches. 001-E80516 Rose Torquing Pliers - 241 .016/.018 double end key 001-207 001-E80518 Rose Torquing Pliers - .018/.022 double end key Designed to place torque in a specific section of arch wire without distortion in the remainder of the wire. The pliers use a key (either .016/.018 or .018/.022) that torques the section between holding beaks. Labial and lingual torque can be placed adjacent to each other easily. Torque can be limited to a single tooth. 100-550 Replacement keys 001-618 .016/.018 doubled ended 001-822 .018/.022 doubled ended 100-208 001-E80516 010-145 800.558.7687 | 920.457.5051 Instruments 242 MasterLine TM BRACKET REMOVERS 001-E345RT Direct Bond Bracket Remover - narrow 001-E346RT Direct Bond Bracket Remover - wide 001-E345RT 001-E346RT NarrowWide These pliers are specially designed for quick and comfortable removal of direct bond brackets. Dual chisel tips wedge between bracket base and tooth. May be used mesialdistally or incisal-gingivally. 001-406NNARROW: 2 replacement tips and wrench. Tip width: .070”/1.78 mm 001-405WIDE: 2 replacement tips and wrench. Tip width: .125”/3.18 mm 001-E348RT Padded DB Bracket Remover - narrow 001-E349RT 001-E348RT 001-E349RT Padded DB Bracket Remover - wide NarrowWide Designed for quick and comfortable removal of direct bond brackets. Can also be used to remove remaining adhesive. Pad rests on incisal surface and chisel tip wedges between bracket base and tooth. 3/16” diameter heat sterilizable pad comes standard with instrument. 1/4” diameter heat sterilizable pad also available individually. Heat sterilizable replacement pads 012-076 3/16” (4.75 mm) 012-077 1/4” (6.35 mm) 001-406NNARROW: 2 replacement tips and wrench. Tip width: .070”/1.78 mm 001-405WIDE: 2 replacement tips and wrench. Tip width: .125”/3.18 mm 001-E301 001-E301 Direct Bond Bracket Remover Novel angulated “cutter” style bond remover design that is particularly effective with ceramic brackets. Cutter style debonding makes removing Radiance brackets even easier. 001-302 Lingual Debonding Pliers Designed to remove lingual bonds such as lingual brackets and bite blocks. The unique design allows for easy and comfortable debonding. Debonding blades are parallel when placed along mesial and distal sides of ceramic brackets, ensuring consistent debonding. www.americanortho.com 001-302 LIGATING INSTRUMENTS 243 Instruments 001-2104 Ligature Director For your choice and convenience, one end is straight and notched, the other end is angled. Fine tips make it ideal for working around mini brackets. Stainless steel. 010-750 Speedo Ligature Director and Remover Double ended stainless steel for placing and removing plastic ligatures. Reduces stress on newly bonded brackets during ligation. 010-009 Single End Explorer This explorer is extremely tough with excellent memory. Stainless steel spring wire. 010-773 Speedo Ligature Director Durable stainless steel with both ends used for placing plastic ligatures. 001-101 001-101S - with adjustable screw Force Module Separator Used to place anterior or posterior plastic separator modules. Contra angle beak reduces risk of tissue damage. Stainless steel. 001-250C Coon Style Ligature Tying Pliers For the application and tying of ligatures, channel automatically locks wire ends as tips spread. For use with preformed steel ligatures. Stainless steel. 010-009 001-2104 010-773 010-750 Use only cane-loaded ligatures with Speedo instruments. 001-250C 001-101 800.558.7687 | 920.457.5051 Instruments 244 MasterLine TM BAND REMOVERS 001-026 Band Slitting Instrument Shear cuts upper and lower bands with a minimum of patient discomfort by gripping the incisal and gingival edges of the band, towards the interproximal, adjacent to the bracket. May also be used to remove direct bond attachments. Caution: avoid bracket flange and tie wing. 001-E347 Posterior Band Remover - short beak Ideal for posterior band removal. When padded tip is on the occlusal of the molar, the removing tip is in an ideal position to catch the edge of the band. 3/16" diameter heat sterilizable pad comes standard with instrument; 1/4" diameter heat sterilizable pad also available individually. Heat sterilizable replacement pads 012-076 3/16” (4.75 mm) 012-077 1/4” (6.35 mm) 001-E347L Posterior Band Remover - long beak Designed for better accessibility to distal areas, these pliers are ideal for posterior band removal. 3/16” diameter heat sterilizable pad comes standard with instrument; 1/4” diameter sterilizable pad also available individually. Heat sterilizable replacement pads 012-076 3/16” (4.75 mm) 012-077 1/4” (6.35 mm) 001-E347XL Posterior Band Remover - extra long beak The extra long beak introduces an even longer set of pliers for clinicians and chairside assistants, providing extra reach to the posterior region. The beak is approximately 25% longer and the handle is approximately 20% longer than the “long beak” style of posterior band remover. 3/16” diameter heat sterilizable pad 001-E347XL comes standard with instrument; 1/4” diameter sterilizable pad also available individually. Heat sterilizable replacement pads 012-076 3/16” (4.75 mm) 012-077 1/4” (6.35 mm) 001-E347 001-026 www.americanortho.com 001-E347L SPECIALTY INSTRUMENTS 100-107 Surgical Hook Crimping Pliers Two grooved inserts maintain a firm grip on the tube as it is delivered to the arch wire. Securely crimps tube at three points to prevent the ends from flaring. 100-107A Arch Hook Crimping Pliers Two grooved inserts maintain a firm grip on the tube as it is delivered to the arch wire. Securely crimps the tube at three points to prevent the ends from flaring. Lower beaks are thinner to accommodate curvature of arch hook. 100-109 .018 Slot 100-111 .022 Slot Cap Removing Pliers Safely and easily removes convertible caps. Instrument places very little force on the tube, making it particularly effective with direct bond tubes. Replacement blades (5) 100-110 .018 slot 100-112 .022 slot 001-E344RT Adhesive Removing Pliers Excess adhesive is easily removed after debonding with these specially designed pliers. The shorter beak features a stainless steel tip while the longer beak has a plastic interchangeable pad. 1/4” diameter heat sterilizable pad comes standard with instrument. 012-077 001-407 Heat sterilizable replacement pads 1/4” (6.35 mm) Replacement tip and wrench. Tip dimension: .062”/1.57 mm 100-107 Securely crimps tube at three points 001-E344RT 100-109 100-111 100-107A 800.558.7687 | 920.457.5051 245 Instruments MasterLine TM 246 Instruments BRACKET AND BAND PLACING INSTRUMENTS 001-800S 001-100A 001-100 678-212M Direct Bond Bracket Holders 001-100 001-106 - Kit of 6 001-100F For use with any bracket from a wide twin to a single. Reverse action holds bracket firmly and releases smoothly. 001-800S - with curved tip Ideal for placing labial and lingual direct bond attachments due to its slight curve. Serrated tips and reverse action for positive holding. 001-100A - with alignment tip This double ended instrument makes correct bracket placement easier by using the alignment tip in the arch wire slot and adjusting alignment. It can also be used for flash removal. 678-212M - Hu-Friedy Direct Bond LP Tube Holder Designed to fit inside the positioning guides of LP Low Profile tubes and hold the tube securely during bonding at the posterior. 001-100F - with fine tip Use this instrument for firmly holding smaller or mini brackets. 001-222 Positive Positioner Designed to hold any direct bond attachment. Easy forward or backward releasing will not dislodge brackets. Lightweight, hard anodized aluminum. 010-013 Double Ended Band Seater 001-222 Featuring sharp and distinct serrated tips on both ends for seating and contouring bands efficiently. 010-013 010-500 861-210 High Heat Bite Stick Hygienic and economical, this bite stick seats bands easily with a steel, triangular tip which allows easy access to interproximal area. Sold three per package. Heat resistant plastic can be used in all heat sterilizers up to 370°F. 010-500 Mallet Handled Band Pusher Offering superior control, the mallet handle and serrated tip provide a firm grip for pushing, burnishing, and seating bands. 010-014 6” College Tweezers A stainless steel multi-functional tweezers with longer, serrated tips. 010-012 Perry Dressing Tweezers This popular stainless steel multi-functional tweezers features serrated, angled tips. 010-014 010-012 www.americanortho.com 861-210 247 010-776 Mathieu Needle Holder 010-776 010-775M Mini Mathieu Needle Holder A Mathieu with tapered, serrated tips specially designed for ligature application. Super fine tip and short beaks allow ligatures to be firmly gripped without intruding into the lumen. Stainless steel with locking handle. 010-775M 010-775 Mathieu Needle Holder 010-775 010-775N Mathieu Needle Holder - narrow For easy application of ligatures. Serrations along entire length of tip allow for application of chain elastics as well as ligatures. Stainless steel with locking handle. 010-775N 010-8015 Smaha Forceps - straight Ultra thin straight tips are especially useful for placement in difficult areas. Stainless steel with serrated tips and locking handle. 010-8015 010-771 Hemostat 5" straight hemostatic forceps. Stainless steel with serrated tips and locking handle. 010-772 Hemostat - fine tip 4 3/4" straight mosquito hemostatic forceps. Stainless steel with serrated tips and locking handle. 010-771 010-772 800.558.7687 | 920.457.5051 Instruments LIGATING INSTRUMENTS SPECIALTY INSTRUMENTS & ACCESSORIES Instruments 248 001-505 - Small 001-506 - Large 100-400 Distal Twister TM 010-008 Cinchback bends are quick and easy by inserting the tip over the distal end of the arch wire and twisting in the desired direction. Small size is ideal for wire sizes up to .018 round and square sizes up to .016 x .016. The large will accommodate round wire up to .020, and rectangular wire up to .021 x .025. 001-501 100-400 Adjustable Enamel Stripper Specially designed and developed for easy, efficient removal and recontouring of the interproximal tooth enamel, for the widening of contact points or for the removal of overhanging fillings. Sterilizable. Kit: Includes enamel stripper, 12 single and double sided steel strips of assorted grits, instructions 010-015 001-102 010-751 100-700 001-505 Replacement steel strips, single sided grit 100-401 12 fine grit 100-402 12 medium grit 100-403 12 coarse grit 100-700 Convertible Cap Remover For ease in removing the convertible caps on molar tubes. Replacement blades are available. 100-701 10 replacement blades 010-015 Alexander Bracket Placement Guide Approximates correct vertical height of bracket placement. Provides vertical placement options of 3.5 mm, 4.0 mm, 4.5 mm, and 5.0 mm depending on tooth. 001-501 Dontrix Gauge Measures the force of coil springs and elastics up to 16 ounces. Marked in one ounce increments. 010-008 Spatula Single ended stainless steel with a combination of flexibility and strength for mixing cement. Smooth, highly polished surface makes cleanup easy. 001-102 Direct Bond Adhesive Remover Double ended curved tips for scraping adhesive in hard to reach places. 010-751 Band Seater/Cement Scaler Serrated band seating tip on one end and curved tip on the other end for scraping excess adhesive. www.americanortho.com 249 010-011 Stainless Steel Mouth Mirror 010-011 007-005 Durable stainless steel, front surface mirror. 861-099 Plastic Mouth Mirror 861-099 Made from durable disposable white nylon with precision ground glass mirror for low distortion. 24 pieces per package. 007-005 Heavy Duty Wire Cutter Ideal for cutting facebows - both inner and outer bows. Well honed cutting edges will not nick the wire. Blades will lock in closed position for safe storage. Features a hard chrome finish for a more professional look and soft vinyl grips for comfort and leverage. Another "must" for every office and lab. Maximum cutting capacity: .080" diameter stainless steel. 010-835 Pliers Rack White plastic rack holds instruments with tips up for easy identification. Cold sterilize. 5 1/2” x 9” x 4 3/4” (13.75 cm x 22.5 cm x 11.88 cm) 010-836 Instrument Tray White plastic tray has 7 compartments that hold instruments conveniently and a multipurpose storage tray. Cold sterilize. 2 1/8” x 6 3/16” x 8” (5.4 cm x 15.8 cm x 20 cm) 010-010 Boone Gauge Measures for bracket height. Flat surface rests on incisal/occlusal surface of tooth. Fixed pin scribes mark for bracket heights of 3.5 mm, 4 mm, 4.5 mm and 5 mm. 001-6015 Medic 365 Instrument Lubricant Synthetic lubricant and preservative for instruments that offers water repellent surface protection and resistance to heat and oxidation. Available in an 8 ounce dropper bottle. 010-101 Micrometer Direct reading from .0001 to 1 inch. 001-6015 010-835 010-010 010-101 010-836 800.558.7687 | 920.457.5051 Instruments SPECIALTY INSTRUMENTS & ACCESSORIES Instruments 250 INSTRUMENTS FOR SELF LIGATING BRACKETS Empower Instrument 678-901E - Single prong tip for opening using gingival tail of clip. Double prong tip for opening using facial hole or for pressing wire into bottom of slot during clip closing. Vision LP Instruments 678-901 - single ended for brackets 678-901H - double ended for brackets 678-901MB - double ended for molars and brackets 010-902 - double ended for molars and brackets (optional style) T3 Instruments 010-255 - T3 open/close Instrument 010-255S - T3 open/close instrument, short 678-903 - Hu-Friedy open/close instrument GK-5013 - Hu-Friedy T3 positioning instrument 010-255S 010-255 678-903 GK-5013 678-901 678-901H 678-901E www.americanortho.com 901MB 010-902 INSTRUMENT CARE Instrument care and repair Corrosion can attack any stainless steel It is important to follow strict procedures in the care and maintenance of your instruments. To assure the longevity and corrosion resistance of your investment, follow one of these sterilization methods. NOTE: Be sure to read your sterilization unit’s instruction manual for proper set-up and to adjust for local water conditions. Always follow your unit’s sterilization parameters. instrument from any manufacturer. A little effort to ensure the cleanliness of the part during sterilization goes a long way.Stainless steel surfaces require Dry Heat Sterilization: access to oxygen to form a protective 1. Remove any debris from instruments using a brush or towel. 2. Perform an ultrasonic cleaning using a general purpose cleaner. 3. Dry thoroughly with oil/water-free compressed air or towel. 4. Place instruments on racks. 5. Sterilize following parameters given by sterilization unit manufacturer. 6. Lubricate immediately with a silicone-based lubricant. chromium oxide layer. This chromium oxide layer (passive layer) is what gives stainless steel its corrosion resistance. What prevents oxygen from contact- Autoclaving: ing stainless steel? Moisture, dirt, and 1. Remove any debris from instruments using a brush or towel. 2. Perform an ultrasonic cleaning using a general purpose cleaner. 3. Dry thoroughly with oil/water-free compressed air or towel. 4. Place instruments on autoclave tray with jaws open. 5. Sterilize following parameters given by sterilization unit manufacturer. 6. Allow instruments to cool after sterilization cycle. 7. Remove instruments and ensure instruments are free of moisture by towel drying. 8. Lubricate immediately with a silicone-based lubricant. cement left on the instrument are typical causes that prevent oxygen from contacting stainless steel during the sterilization process. Instruments should be thoroughly brushed clean before sterilization. All instruments should be sterilized in the open position and then thoroughly dried after sterilization, taking special care in the joint areas and crevices. Corroded instruments should never be sterilized with non-corroded instruments as the iron oxide on the corroded instrument can transfer to the non-corroded instrument, attaching itself permanently. Chemclaving (unsaturated chemical vapor): 1. Remove any debris from instruments using a brush or towel. 2. Perform an ultrasonic cleaning using a general purpose cleaner. 3. Dry thoroughly with oil/water-free compressed air or towel. 4. Place instruments on chemclave tray with jaws open. Place layer of paper toweling between instruments. 5. Sterilize following parameters given by sterilization unit manufacturer. 6. Depressurize the equipment and allow instruments to cool after sterilization cycle. 7. Remove instruments and ensure instruments are free of moisture by towel drying. 8. Lubricate immediately with a silicone-based lubricant. Cold Sterilization (disinfection): 1. Remove any debris from instruments using a brush or towel. 2. Perform an ultrasonic cleaning using a general purpose cleaner. 3. Dry thoroughly with oil/water-free compressed air or towel. 4. Immerse instruments in a 2% glutaraldehyde sterilizing solution. 5. Remove the instruments from the sterilizing solution, rinse in water, and towel dry to ensure instrument is free of moisture. 6. Lubricate immediately with a silicone-based lubricant. Helpful Hint: Dipping instruments in a water-based surgical milk prior to ultrasonic cleaning reduces the incidence of spots, stains, and corrosion. Surgical milk is an interface surface corrosion inhibitor and lubricant that helps to ensure proper movement of hinges and provides a protective barrier that arrests discoloration and corrosion during sterilization. 800.558.7687 | 920.457.5051 Instruments Preventing Corrosion 251 Instruments 252 INSTRUMENT CARE INSTRUMENT RECONDITIONING AND REPAIR PROGRAM Instruments need regular preventative check ups. To preserve the accuracy and extend the life of your instruments, it's important to recondition them every 6 to 9 months. American Orthodontics offers precise sharpening, retipping, and reconditioning/polishing of your instruments in a timely manner. We also recondition and repair instruments from other manufacturers (excluding Hu-Friedy). 000-030Sharpen 000-031Retip 000-032Recondition (may include joint adjustment, reserrating, and polishing) www.americanortho.com