Buckeye Fire Equipment
Transcription
Buckeye Fire Equipment
BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 1 BUCKEYE FIRE EQUIPMENT American Made Since 1968 2007 Fire Equipment Product Catalog www.buckeyef.com BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 2 Company and Product Profile Buckeye Fire Equipment A Tradition of Innovation and Reliability In the fire protection industry for over 35 years, the Buckeye Fire Equipment Company is an innovative manufacturer of a complete line of Underwriters Laboratories (UL) Listed fire protection products: • • • • Portable and wheeled fire extinguishers Dry chemical extinguishing agents Firefighting foam concentrates and foam hardware Engineered restaurant fire suppression systems At our 165,000 square foot manufacturing facility located near Charlotte, North Carolina, Buckeye Fire Equipment produces high quality and reliable fire protection equipment for national and international markets. With sales and warehouse centers strategically located throughout the United States, as well as a global network of authorized distributors, Buckeye Fire Equipment is ready to provide its customers with timely and efficient sales, delivery, and service. Fire Extinguishers Portable Hand and Wheeled At the heart of the Buckeye Fire Equipment product lines are the hand-portable dry chemical fire extinguishers. The performance reliability of these extinguishers is a direct result of the stringent controls under which each component is produced. We mill and blend our own dry chemical agents (monoammonium phosphate based [ABC], potassium bicarbonate based [Purple K], and sodium bicarbonate based [Standard]) on site where each batch is tested and verified to meet our in-house and UL quality requirements. In our machining centers we produce our cylinders and valve component parts to exacting standards that are quality-assured by a manufacturing and inspection system certified to the latest revision of the ISO 9001 Quality Standard. On one of the most modern automated process lines in the world, the extinguishers are filled, pressurized, and leak tested to assure that only the highest quality extinguishers reach our customers. ABC Fire Extinguisher at Work Buckeye Fire Equipment also manufactures a wide selection of hazard specific fire extinguishers to meet your individual fire protection needs. These include clean gas extinguishers such as Carbon Dioxide and Halotron™, the Class K Wet Chemical extinguishers used for kitchen fire suppression, Class D extinguishers for use on metal fires, and the Water Mist extinguishers suitable for use on Class A fires where a Class C hazard may also exist. BuckeyeCOMPLETE 5/24/07 4:53 PM Page 3 If your situation requires more fire-stopping power, Buckeye offers clean gas agents and all three of our dry chemical agents in easily transportable wheeled units. Depending on the extinguishing agent you select, these wheeled units are available in capacities ranging from 50 lbs. to 350 lbs. Please refer to the Catalogue Product Tables for the models and sizes offered. Buckeye Kitchen Mister UL 300 Restaurant Fire Suppression System Firefighting Foams and Hardware With one of the world’s largest capacity foam blending operations, Buckeye Fire Equipment produces a comprehensive line of firefighting foam concentrates recognized through independent tests as among the best in the industry. Our wide array of foam concentrates assures that there is one designed to meet your fire suppression requirements. As committed as we are to the quality and performance of our foam concentrates, we are also committed to protecting the environment our foam concentrates are manufactured without any EPA reportable components. Buckeye Fire Equipment is proud to introduce the next generation of UL-300 Restaurant Cooking Area Fire Suppression Systems, the Buckeye Kitchen Mister Suppression System. Although many restaurant systems brag about product innovation, improved technology, fire fighting ability, and “ease of installation”, the Buckeye Kitchen Mister is the first product to truly deliver on that promise. By combining the fire fighting ability of misting technology, common sense features, and time saving patented innovations, the Kitchen Mister makes all other systems seem complicated and outdated. If reducing installation time by up to 50% is important to you, then your system has arrived. Knocking Down the Fire with Buckeye Foam To complement the firefighting foam product line, Buckeye Fire Equipment manufactures foam storage, proportioning, and delivery hardware that can be engineered for your specific needs. This hardware may be used in both fixed or portable system installations. Our expert technical staff can assist you in determining the most effective application for your potential hazard. Buckeye Fire Equipment Research and Development Center Customer Driven to Serve You Buckeye Fire Equipment is a customer driven company that prides itself on earning your business with every call. If you have questions about any of the products in this catalogue please do not hesitate to contact us. BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 4 Portable Extinguisher Selection Guide The National Fire Protection Association (NFPA) has established the requirements for the number, size, placement, performance, and maintenance of portable fire extinguishers. These requirements are contained in NFPA 10, “Standard for Portable Fire Extinguishers”. Within this Standard it is stated that the selection of fire extinguishers for a given situation is determined by the character of the fires anticipated to be encountered, the construction and occupancy of the property to be protected, the ambient temperature of the area where the extinguisher will be located, and other factors that may dictate the selection of a particular type of extinguisher. CLASSIFICATION Generally, fire extinguishers are selected based on the hazard(s) they are intended to protect. Classifications have been established to categorize what type of extinguishing agent is best suited for the fire hazard. These classifications are A, B, C, D, and K. A fire extinguisher assigned a Class A classification is suitable for use on ordinary combustibles; wood, paper, cloth, rubber, and many of the plastics. The B classification is intended for use on flammable liquids, combustible liquids, petroleum greases, oils, oil-based paints, solvents, alcohols, and flammable gases. Class C extinguishers are for use on fires involving energized electrical equipment. For fires involving combustible metals (magnesium, lithium, zirconium, etc.), Class D extinguishers are best to use. An extinguisher designated Class K best protects cooking appliances that utilize cooking media such as vegetable oils and animal fats. RATING Along with the classification, the numerical rating of an extinguisher is an important factor in the proper selection of an extinguisher. The rating is a measure of the extinguishing potential of the fire extinguisher and is developed on the basis of comparative fire tests (Reference UL 711, Standard for Rating and Testing of Fire Extinguishers). Only the Class A and Class B classifications carry numerical ratings. Basically, the higher the number associated with the classification letter, the larger the fire the extinguisher has the potential to put out. Please refer to NFPA 10 when determining the rating necessary for the floor area requiring protection. There are no numerical ratings associated with Class C, D, or K classifications. Comparative fire tests are not conducted. In the case of Class C, the electrical nonconducting characteristics of the agent are verified, not the extinguishing potential. For Class D, only the amount of agent and application method needed to control a metal fire of a certain size and type is tested. And for Class K, the fire extinguishing characteristics of the extinguisher have only been determined for a single size fire source. In the typical rating of an extinguisher, for example 3A-40B:C, the 3 and the 40 indicate the extinguishing potential of the unit for a Class A and Class B fire respectively. The C indicates that the extinguishing agent will not conduct electricity, preventing shock to the user if used on energized electrical equipment. On the following page is a reference chart with the basic rating parameters for extinguishers. SUMMARY To provide the best protection of life and property from the destructive force of fire, it is critical that the proper fire extinguisher selection be made. The Classification and Rating of an extinguisher are vital pieces of information for making that selection. Using NFPA 10 for guidance, matching the right fire extinguisher to the potential hazard, providing a sufficient number of extinguishers for the area to be protected, locating the extinguishers for maximum visibility and accessibility, and personnel trained in the use and maintenance of the extinguisher will significantly lessen the risk of loss. BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 5 EXTINGUISHER PLACEMENT AND RATING REFERENCE CHARTS Placement/Accessibility Of Extinguisher CLASS A FIRE HAZARD MAXIMUM TRAVEL DISTANCE CLASS B FIRE HAZARD 75 Feet 50 Feet Maximum area that one extinguisher can protect and meet the 75’ rule = 11,250 sq. ft. Maximum area that one extinguisher can protect and meet the 50’ rule = 5000 sq. ft. CLASS C FIRE HAZARD CLASS D FIRE HAZARD CLASS K FIRE HAZARD In accordance with the Class A or B hazard it is protecting 75 Feet Maximum area that one extinguisher can protect and meet the 30’ rule = 1800 sq. ft. 30 Feet Basic Extinguisher Rating Parameters Numerical Rating 1A 2A 3A 4A 6A 10A 20A 30A 40A ORDINARY COMBUSTIBLES FLAMMABLE LIQUIDS Class A Fires (Wood, Paper, Cloth, Rubber) Class B Fires (Gasoline, Oil, Paints, Solvents, Propane) Wood Panel Fire Test 8’x 8’ 10’x 10’ 12’x 12’ 14’x 14’ 17’x 17’ N/A N/A N/A N/A Wood Crib Fire Test Overall Dims. (inches) 20 x 20 x 18 25 x 25 x 24 29 x 29 x 27 32 x 32 x 30 36 x 36 x 34.5 43 x 43 x 40.5 55 x 55 x 57.5 64 x 64 x 64.5 69 x 69 x 71.5 No. of Members 72 112 144 180 230 324 256 324 400 Trade Size of Members (inches) 2 x 2 x 20 2 x 2 x 25 2 x 2 x 29 2 x 2 x 32 2 x 2 x 36 2 x 2 x 43 2 x 4 x 55 2 x 4 x 64 2 x 4 x 69 Numerical Rating 2B 5B 10B 20B 40B 60B 80B 120B 160B Minimum Discharge Required 8 Sec 8* Sec 8* Sec 8* sec 13 Sec 17 Sec 20 Sec 26 Sec 31 Sec *13 Seconds with an “A” rating Fire Test Pan Size (expert) Estimated Novice Capability 5 sq ft 12.5 sq ft 25 sq ft 50 sq ft 100 sq ft 150 sq ft 200 sq ft 300 sq ft 400 sq ft 5 sq ft 10 sq ft 20 sq ft 40 sq ft 60 sq ft 80 sq ft 80 sq ft 120 sq ft 160 sq ft ENERGIZED ELECTRICAL COOKING MEDIA Class C Fires (Computers, Electrical Panels, Transformers) Class K Fires (Cooking Appliances) NO FIRE TEST Fire Test Fryer Size Extinguishing agent is tested for electrical nonconductivity. If nonconductive, the “C” symbol is added to the existing classification. 18”x24”x18” Deep Fat Fryer No numerical rating is given for Class C No numerical rating is given for Class K Discharge Time Approx. 60 Seconds There are three general classifications of hazard areas- low, ordinary, and extra. Minimum rating required for low or ordinary hazard areas is 2A. Minimum rating for extra hazard areas is 4A. Maximum floor area that can be protected per unit of A is 3,000 sq. ft. for low hazard. Maximum floor area that can be protected per unit of A is 1,500 sq. ft. for ordinary hazard. Maximum floor area that can be protected per unit of A is 1,000 sq. ft. for extra hazard. To determine the rating necessary for proper protection, divide the total sq. ft. by the unit of A for the hazard. Example: An extinguisher is needed to protect an office area (low hazard) that measures 10,500 sq. ft. Total sq. ft. = 10,500. Unit of A for low hazard is 3,000. The rating necessary to protect the area is 10,500 ÷ 3,000 = 3.5 units of A. Rounding up to the next numerical rating would mean that a 4A-rated extinguisher would be needed to protect the office. If the area were classified as “extra hazard” then the extinguisher would need to be rated 20A (10,500 ÷ 1,000 = 10.5 units of A. Rounded up to the next numerical rating = 20A). BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 6 ABC DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: • Monoammonium Phosphate based dry chemical agent. • Rated for use on “A”, “B”, and “C” class fires. Provides the widest, most practical range of fire protection. • Rechargeable • Steel cylinders with a baked-on polyester enamel coating stand up to harsh environments. • Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards • Optional brass valves on some units. 30 lb. unit has brass valve only TYPICAL USES: Offices, warehouses, woodworking areas, farms, general public assembly areas, and homes. The ABC extinguisher is not recommended for use on sensitive electronic equipment or aircraft structure. Model Part # Alum. Valve Part # Brass Valve Agent Capacity UL Rating Discharge Time Range (ft/m) Operating Pressure Bracket USCG Approval Ship Wt. Height Width Diameter 2.5 ABC V/B 5 ABC 5 ABC V/B 10 TALL ABC 10S ABC 20S ABC 30S ABC 13315 10914 25614 11340 11310 12120 N/A N/A 2.5 lb. (1.13 kg) 1A-10B:C 9 sec 9-15 / 2.7-4.6 100 psi (689 kPa) Vehicle 10915 25615 11341 N/A 12121 20 lb. (9.07 kg) 20A-120B:C 26 sec 12905 30 lb. (13.6 kg) 20A-160B:C 32 sec 25-30 / 7.6-9.1 5 lb. (2.27 kg) 3A-40B:C 14 sec 12-18 / 3.7-5.5 Wall 10 lb. (4.54 kg) 4A-80B:C 4A-60B:C 22 sec 18 sec 15-21 / 4.6-6.4 195 psi (1344 kPa) Vehicle Type B:C Size I Type A Size II Type B:C Size I 5.5 lbs. (2.5 kg) 14.75 in (37.5 cm) 4.875 in (12.4 cm) 3.375 in (8.6 cm) 10 lbs. 10.25 lbs (4.5 kg) (4.7 kg) 16.375 in (41.6 cm) 7.25 in (18.4 cm) 4.25 in (10.8 cm) Wall Type A Size II Type B:C Size II 18.25 lbs. (8.3 kg) 21 in (53.3 cm) 7.75 in (19.7 cm) 5.125 in (13 cm) 18.75 lbs. (8.6 kg) 16.75 in (42.5 cm) 8.25 in (21 cm) 6 in (15.2 cm) Type A Size II Type B:C Size III Type A Size II Type B:C Size IV 33.5 lbs. (15.2 kg) 21.25 in (53.8 cm) 52.25 lbs. (23.7 kg) 27.375 in (69.4 cm) 8.75 in (22.2 cm) 7.5 in (19.1 cm) BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 7 STANDARD DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: • Sodium Bicarbonate based dry chemical agent. • Rated for use on “B” and “C” Class fires. • Rechargeable • Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments. • Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards. TYPICAL USES: Kitchens, garages, boats, vehicles, and extinguisher use training. The Standard extinguisher is not recommended for use on sensitive electronic equipment. Model Part # Aluminum Valve Agent Capacity UL Rating Discharge Time Range Operating Pressure Bracket USCG Approval Ship Wt. Height Width Diameter 2.5 STD V/B 13415 2.5 lbs. (1.13 kg) 10 B:C 9 seconds 9-15 ft (2.7-4.6 m) 100 psi (689 kPa) Vehicle 5.5 STD 11014 5.5 STD V/B 13514 5.5 lbs. (2.50 kg) 40 B:C 14 seconds 12-18 ft (3.7-5.5 m) 20S STD 12220 20 lbs. (9.07 kg) 120 B:C 26 seconds 15-21 ft (4.6-6.4 m) 195 psi (1344 kPa) Wall Vehicle Type B:C Size I 5.5 lbs. (2.5 kg) 14.75 in (37.5 cm) 4.875 in (12.4 cm) 3.375 in (8.6 cm) 10 STD 11840 10 lbs. (4.54 kg) 10.5 lbs. 10.75 lbs. (4.8 kg) (4.9 kg) 16.375 in (41.6 cm) 7.25 in (18.4 cm) 4.25 in (10.8 cm) Wall Type B:C Size II Type B:C Size III 18.25 lbs. (8.3 kg) 21 in (53.3 cm) 7.75 in (19.7 cm) 5.125 in (13 cm) 33.5 lbs. (15.2 kg) 21.25 in (53.8 cm) 8.75 in (22.2 cm) 7.5 in (19.1 cm) BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 8 PURPLE K DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: • Potassium Bicarbonate based dry chemical agent. • Rated for use on “B”, and “C” class fires. Most effective dry chemical agent for Class B fires • Rechargeable • Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments. • Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards • Optional brass valves on some units. 30 lb. unit has brass valve exclusively. TYPICAL USES: Garages, service bays, boats, vehicles, fuel storage and transfer areas. The Purple K extinguisher is not recommended for use on sensitive electronic equipment. Model Part # Alum. Valve Part # Brass Valve Agent Capacity UL Rating Discharge Time Range Operating Pressure Bracket USCG Approval Ship Wt. Height Width Diameter 2.5 PK V/B 13515 5 PK 11214 5 PK V/B 25914 10 PK 11740 20S PK 12620 30S PK N/A N/A N/A N/A N/A 12621 12805 10 lbs (4.54 kg) 80 B:C 22 seconds 20 lbs. (9.07 kg) 120 B:C 26 seconds 30 lbs. (13.6 kg) 160 B:C 32 seconds 2.5 lbs (1.13 kg) 10 B:C 9-15 ft (2.7-4.6 m) 100 psi (689 kPa) Vehicle 5.5 lbs (2.49 kg) 14.75 in (37.5 cm) 4.875 in (12.4 cm) 3.375 in (8.6 cm) 5 lbs. (2.27 kg) 20 B:C 9 seconds 12-18 ft (3.7-5.5 m) Wall 15-21 ft (4.6-6.4 m) 195 psi (1344 kPa) Vehicle 25-30 ft (7.6-9.1 m) Wall Type B:C Size I Type B:C Size II Type B:C Size III Type B:C Size IV 10 lbs. (4.5 kg) 18.25 lbs. (8.3 kg) 21 in (53.3 cm) 7.75 in (19.7 cm) 5.125 in (13 cm) 33.5 lbs. (15.2 kg) 21.25 in (53.8 cm) 52.25 lbs. (23.7 kg) 27.375 lbs. (69.4 cm) 10.25 lbs. (4.6 kg) 16.375 in (41.6 cm) 7.25 in (18.4 cm) 4.25 in (10.8 cm) 8.75 in (22.2 cm) 7.5 in (19.1 cm) BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 9 HALOTRON™ HAND HELD AND WHEELED STORED PRESSURE FIRE EXTINGUISHERS FEATURES: • Residue-free Hydrochlorofluorocarbon gas agent pressurized with argon. • Excellent replacement for Halon 1211 extinguishers. • Rechargeable steel cylinders with baked-on polyester enamel coating that stands up to harsh environments. Wheeled units have DOT approved 4BW240 cylinders, rugged frames, and semi-pneumatic tires. • All units are manufactured to ANSI/UL 2129 and ANSI/UL 711 Standards. • Optional chrome-plated brass valves on some units (standard on Wheeled Extinguishers). TYPICAL USES: Computer rooms, telephone switch rooms, data storage areas, boats, and flight lines. Model 2.5F Part # Alum. Valve Part # Brass Valve Agent Capacity 70258 2.5F V/B 70251 Height Width Diameter 70259 2.5H V/B 70256 Not Available 2.5 lbs (1.13 kg) 2B:C UL Rating Discharge Time Range Operating Pressure Bracket USCG Approval Ship Wt. 2.5H 5F 5F V/B 5H 5H V/B 11 15 70510 70550 75550 75555 71100 71550 70511 70551 75551 75556 71101 71551 5 lbs. (2.27 kg) 5.5 lbs. (2.49 kg) 11 lbs. (5 kg) 1A-10B:C 5B:C 9 seconds 6-10 ft (1.8-3 m) Wall Vehicle Wall Not Applicable 9-15 ft (2.7-4.5 m) Vehicle 5.25 lbs (2.4 kg) 5.5 lbs. 5.75 lbs (2.49 kg) (2.6 kg) 13.375 in (34 cm) 5.625 in 6.75 in (14.3 cm) (17.1 cm) 3.375 in (8.6 cm) 100 psi (689 kPa) Wall Vehicle 9.25 lbs. (4.2 kg) 6.5 in (16.5 cm) Wall Type B:C Size I 9.5 lbs. 10 lbs. (4.3kg) (4.5 kg) 16.375 in (41.6 cm) 7.25 in 6.5 in (18.4 cm) (16.5 cm) 4.25 in (10.8 cm) Vehicle 10.25 lbs. (4.7 kg) 7.25 in (18.4 cm) 15.5 lbs. (7.03 kg) 2A-10B:C 13 seconds 12-18 ft (3.7-5.5 m) 125 psi (862 kPa) Wall Type B:C Size II 21.25 lbs. 25.75 lbs. (9.6 kg) (11.7 kg) 17.5 in (44.5 cm) 8.625 in (21.9 cm) 7 in (17.8 cm) Wheeled Extinguishers Model Part # Capacity W-65 76500 W-150 71500 65 lbs (29.5 kg) 150 lbs (68 kg) UL Rating 4A-40B:C 10A-80B:C Discharge Time 17 seconds 23 seconds Range 15-25 ft (4.6-7.6 m) 23-36 ft (7-10.7 m) Unit Height x Width x Depth 50 x 24 x 41.5 in (127 x 61 x 105 cm) 62 x 24 x 41.5 in (157.5 x61 x 105 cm) Hose Diameter x Length .75 in x 25 ft (1.9 cm x 7.6 m) 1 in x 40 ft (2.5 cm x 12.2 m) Ship Weight 300 lbs (136 kg) 480 lbs (218 kg) BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 10 CARBON DIOXIDE HAND-HELD AND WHEELED FIRE EXTINGUISHERS FEATURES: • Residue-free carbon dioxide gas extinguishing agent. • Hand-held units use aluminum cylinders with a baked-on polyester enamel coating to withstand harsh environments. • Wheeled units are constructed with spun steel cylinders, rugged frames, and pneumatic tires and are designed to be easily operated by one person. • All units manufactured to ANSI/UL 154 and ANSI/UL 711 Standards and use DOT compliant cylinders. • Plated brass valves on both hand-held and wheeled units. • Optional tow loops offered on the wheeled extinguishers. TYPICAL USES: Refineries, shipboard, laboratories, construction sites, chemical plants, and manufacturing facilities. Model Part Number Agent Capacity UL Rating Discharge Time Range Bracket USCG Approval Ship Wt. Height Width Diameter 5CD 45100 5 lbs. (2.27 kg) 5B:C 8 seconds Hand-Held Extinguishers 10CD 45600 10 lbs. (4.54 kg) 15CD 20CD 46100 46600 15 lbs. (6.80 kg) 20 lbs. (9.07 kg) 10B:C 10 seconds 15 seconds 20 seconds 4-8 ft (1.2-2.4 m) Wall Type B:C Size I Type B:C Size II 13.75 lbs. (6.3 kg) 27.75 lbs. (12.6 kg) 37.75 lbs. (17.1 kg) 49.0 lbs. (22.2 kg) 17.375 in (44.1 cm) 19.75 in (50.2 cm) 26.375 in. (67 cm) 26.875 in (68.2 cm) 8.25 in (21 cm) 12 in (30.5 cm) 13 in (33 cm) 5.25 in (13.3 cm) 6.89 in (17.5 cm) 8 in (20.3 cm) Wheeled Extinguishers Model Part # Capacity C-50-SE 35050 C-100-SE 35100 50 lbs. (22.68 kg) 100 lbs. (45.36 kg) UL Rating 20B:C Discharge Time 40 seconds 80 seconds Range 15 ft (4.6m) Unit Height x Width x Depth 60 x 30 x 21 in (152.4 x 76.2 x 53.3 cm) 65 x 30 x 21 in (165.1 x 76.2 x 53.3 cm) Hose Dia x Length 1 in x 15 ft (2.5 cm x 4.56 m) 1 in x 40 ft (2.5 cm x 12.2 m) Ship Weight 250 lbs. (113.4 kg) 390 lbs. (176.9 kg) BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 11 AUTOMATIC SPOT PROTECTION FEATURES: • Designed to provide supplemental protection suitable for some local and total flood applications. • Two mount styles available, charged with multipurpose dry chemical (ABC) or clean agent Halotron™. • The cylinders are constructed and tested to the same engineering standards as our portable extinguishers. • These units are not Underwriters Laboratories Listed and are not intended for use in lieu of an engineered system. They are not to be multiple mounted. VERTICAL MOUNT STYLE Agent Part No. Capacity (lb./kg) Ship Wt. (lb./kg) Operating Pressure Length Diameter Max Total FloodVolume Max Total FloodHeight above Hazard Local Application Coverage Areas Multipurpose ABC Dry Chemical 80250 80501 81001 82001 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 100 psi (689 kPa) 195 psi (1344 kPa) 15.25 in 17.25 in 17.625 in 21.875 in 3.375 in 4.25 in 6.0 in 7.5 in 120 cu ft 180 cu ft 7.5 ft 4 ft x 4 ft 4 ft x 6 ft Halotron™ 87100 87200 18 lbs/ 8.2 kg 25 lbs/ 11.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg 100 psi (689 kPa) 17.875 in 21.875 in 7.0 in 7.5 in 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft 13 ft 14 ft 8 ft 10 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft Max Local Application- Height Above Hazard = 4 feet for all models HORIZONTAL MOUNT STYLE Agent Part No. Capacity (lb./kg) Ship Wt. (lb./kg) Operating Pressure Length Diameter Max Total FloodVolume Max Total FloodHeight above Hazard Local Application Coverage Areas Mounting Bracket Multipurpose ABC dry chemical 80251 80521 81021 82021 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 100 psi (689 kPa) 195 psi (1344 kPa) 14.25 in 17.25 in 20.875 in 21.875 in 3.375 in 4.25 in 5.125 in 7.5 in 120 cu ft 180 cu ft 7.5 ft Halotron™ 87105 87205 18 lbs/ 8.2 kg 25 lbs/11.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg 100 psi (689 kPa) 17.875 in 21.875 in 7.0 in 7.5 in 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft 13 ft 14 ft 8 ft 10 ft 4 ft x 4 ft 4 ft x 6 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft 700287 700270 700226 700229 700228 700229 Max Local Application- Height Above Hazard = 4 feet for all models BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 12 DRY CHEMICAL WHEELED FIRE EXTINGUISHERS FEATURES: • • • • • • • • • Three choices in dry chemical agents are available to suit your particular fire protection needs: Monoammonium Phosphate (ABC), Sodium Bicarbonate (Standard), and Potassium Bicarbonate (Purple K). The ABC extinguisher is rated for use on “A”, “B”, and “C” class fires, providing the widest, most practical range of fire protection. The Standard and Purple K extinguishers are rated for use on B:C classes of fires. Designed for one-man operation. Easily transported through doorways and over rough terrain. All models are also available as stationary units. Every model is rechargeable. Rugged steel cylinders and frames with baked-on polyester enamel coatings stand up to harsh environments. Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards. Plated brass cylinder valves and hose valve assemblies. All pressurized cylinders are DOT approved. Extinguishers part numbered 30010, 30110, 30030, 30310, & 31210 are USCG approved. TYPICAL USES: Offshore rigs, ship docks, refineries, chemical plants, aircraft ramps, remote construction sites, large laboratories, processing plants, storage and loading areas. These extinguishers are not recommended for use on sensitive electronic equipment. WHEELED EXTINGUISHER PHYSICAL ATTRIBUTES MODEL PART NO. SHIP WEIGHT HEIGHT WIDTH DEPTH HOSE LENGTH x DIA WHEEL DIAMETER A-50-SP 30010 K-50-SP 30030 193 lbs. (88 kg) 47 inches (119 cm) 24 inches (61 cm) 26.5 inches (67 cm) 25 ft. x .50 in (7.6 m x 1.3 cm) 12.3 x 3.5 in (31.3 x 8.9 cm) A-150-SP K-150-SP A-150-RG K-150-RG 30110 30310 31120 31320 343 lbs. (156 kg) 51 inches (128 cm) 26 inches (66 cm) 38 inches (96.5 cm) S-150-RG 31220 413 lbs. (188 kg) 438 lbs. (199 kg) 50 inches (127 cm) 24 inches (61 cm) 42 inches (105 cm) A-150-RG A-150-PT 31140* 31150** 31340* 31350** 31240* 31250** 31110 K-150-PT 31310 S-150-PT 31210 K-150-RG S-150-RG A-350-RG K-350-RG S-350-RG A-350-PT K-350-PT S-350-PT 32120* 32140** 32320* 32340** 32220* 32240** 32110* 32130** 32310* 32330** 32210* 32230** 448 lbs. (204 kg) 55 inches (139 cm) 32 inches (81.3 cm) 46 inches (117 cm) 16 x 4 in (40.6 x 10.2 cm) 50 ft x .75 in (15.2 m x 1.9 cm) 50 inches (127 cm) 24 inches (61 cm) 42 inches (105 cm) 16 x 4 in (40.6 x 10.2 cm) 810 lbs. (368 kg) 860 lbs. (391 kg) 700 lbs. (318 kg) 750 lbs. (341 kg) * Steel Wheels ** Steel wheels with rubber tread 473 lbs. (215 kg) 345 lbs. (157 kg) 370 lbs. (168 kg) 36 x 2.5 in (91.4 x 6.4 cm) 36 x 2.5 in (91.4 x 6.4 cm) * Steel Wheels 58 inches (147 cm) 36 inches (91.4 cm) 48 inches (122 cm) 50 ft x 1 in (15.2 m x 2.5 cm) ** Steel wheels with rubber tread BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 13 ABC WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE TIME A-50-SP 30010 50 lbs. (22.7 kg) 30A-160B:C 35 seconds A-150-SP 30110 31120 31140 31150 31110 32120 32140 32110 32130 A-150-RG A-150-PT A-350-RG A-350-PT DISCHARGE RANGE 25-35 ft (7.6-10.7 m) 47 seconds 125 lbs. (56.7 kg) 40A-240B:C 43 seconds 45 seconds 300 lbs. (136 kg) 40A-320B:C 30-40 ft (9.1-12.2 m) 53 seconds 57 seconds PURPLE K WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE TIME K-50-SP 30030 50 lbs. (22.7 kg) 160 B:C 34 seconds K-150-SP 30310 31320 31340 31350 31310 32320 32340 32310 K-150-RG K-150-PT K-350-RG K-350-PT DISCHARGE RANGE 25-35 ft (7.6-10.7 m) 54 seconds 125 lbs. (56.7 kg) 57 seconds 320B:C 54 seconds 30-40 ft (9.1-12.2 m) 56 seconds 300 lbs. (136 kg) 58 seconds 32330 STANDARD WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL S-150-RG S-150-PT S-350-RG S-350-PT PART NO. 31220 31240 31250 31210 32220 32240 32210 32230 AGENT CAPACITY UL RATING DISCHARGE TIME 150 lbs. (68 kg) 240B:C 48 seconds 43 seconds 350 lbs. (159 kg) 59 seconds 320B:C 50 seconds DISCHARGE RANGE 30-40 ft (9.1-12.2 m) BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 14 SPECIALTY FIRE EXTINGUISHERS WET CHEMICAL – CLASS K • Contains a blend of Potassium Acetate and Potassium Citrate that is extremely effective in suppressing high temperature fires fueled by the unsaturated cooking oils used in today’s restaurant appliances. The agent is applied by a misting discharge nozzle that prevents the splashing and spreading of the oils. This extinguisher is designed to complement existing pre-engineered hood systems. Also carries an “A” Rating. • Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model Part # Agent Capacity UL Rating Discharge Time Operating Pressure Bracket Ship Wt. Height Width (including hose) Cylinder Diameter Construction WC-6 Liter 50006 6 Liter (1.59 gallons) 1-A:K (Tested to extinguish one 18” X 24” fryer) 54 seconds 100 psi (689 kPa) Wall 22 lbs. (10 kg) 19.25 inches (48.9 cm) 9 inches (22.9 cm) 7 inches (17.8 cm) Stainless steel cylinder with plated brass valve WATER • Uses water as the extinguishing agent. This economical and environmentally friendly extinguisher is ideal for schools, theaters, retail storerooms, and anywhere Class A hazards exist. • Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model Part # Agent Capacity UL Rating Discharge Time Operating Pressure Bracket Ship Wt. (empty) Height Width (including hose) Cylinder Diameter Construction 500 50000 2.5 gallon (9.6 liters) 2A 50 seconds 100 psi (689 kPa) Wall 7.75 lbs. (3.5 kg) 24.5 inches (62.2 cm) 9 inches (22.9 cm) 7 inches (17.8 cm) Stainless steel cylinder with plated brass valve BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 15 SPECIALTY FIRE EXTINGUISHERS WATER MIST • Uses deionized water as the extinguishing agent. The unique misting nozzle creates a fine water spray that improves the cooling and soaking characteristics of the agent and limits the scattering of burning material. This extinguisher is the right choice for Class A fires where there is a potential for Class C (electrical) safety hazards. Ideal for hospitals, clean rooms, and telecom facilities. The non-magnetic properties of the extinguisher make it perfect for use in proximity to MRI equipment. • Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model Part # Agent Capacity UL Rating Discharge Time Operating Pressure Bracket Ship Wt. Height Width (including hose) Cylinder Diameter Construction WM250 51000 2.5 gallon (9.6 liters) 2A:C 73 seconds 100 psi (689 kPa) Wall 29.5 lbs. (13.4 kg) 28 inches (71.1 cm) 14 in (35.6 cm) 7 inches (17.8 cm) Stainless steel cylinder with plated brass valve COMBUSTIBLE METALS – CLASS D • Specially designed for use on combustible metals fires, this extinguisher features a discharge assembly that keeps the operator at a safe distance while providing accurate application of the agent on the fire. From the heat of the fire, the sodium chloride based agent forms a crust to exclude air from the burning material. • Manufactured to Factory Mutual standards. Model Part # Agent Capacity FM Rating Discharge Time Operating Pressure Bracket Ship Wt. Height (with hose) Width (with hose) Cylinder Diameter Construction 30D 52100 30 lbs. (13.6 kg) D 28 seconds 195 psi (1344 kPa) Wall 55 lbs. ( 24.95 kg) 33 inches (83.8 cm) 16 inches (40.6 cm) 8 inches (20.3 cm) Steel Cylinder BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 16 Buckeye Kitchen Mister UL 300 Restaurant Fire Suppression System Protect Your Business With The Best! Discharge Nozzles All five (5) Kitchen Mister nozzles come equipped with a color identification band, red, blue, green, white, and yellow. This allows for easy identification of the nozzle even when it’s installed in difficult locations such as a duct or plenum area. The nozzle is also stamped with its Model Number. System Releasing Module Protecting the modern commercial kitchen from the ever present danger of fire is the reason Buckeye Fire Equipment designed the Kitchen Mister Fire System. Utilizing state of the art misting technology, the Kitchen Mister System extinguishes potentially deadly kitchen fires quicker and more effectively than any other kitchen system ever developed, period. The modern commercial kitchen, with its open flames, hot surfaces, and grease laden environment combine all the elements necessary for a fire. Extinguishing fires quickly, before they can spread, is the best way to limit fire damage and get your operation back in business. Don’t Take Chances, Demand The Best! Simple is Better The constant changes and complicated requirements of most restaurant cooking systems have made design and installation errors a concern for Fire Equipment Distributors everywhere. Obviously, a simple system design reduces the possibility of design and installation errors. At Buckeye we’ve listened to these concerns and understand that simple is better. One look at the Kitchen Mister and you can see what a difference common sense makes: System Cylinders The System Releasing Module has been designed with a viewing window to assure that the actuation cartridge has been properly installed and to see the date written on the cartridge. It also includes high quality ratchets that allow the gas valve to be opened and tested from the SRM. The unit can be mounted directly on a cylinder or can be mounted remotely. It can actuate up to five (5) agent cylinders and does not require a bracket for wall mounting. Buckeye Shielded Cable The Kitchen Mister Shielded Cable Interface is used to connect Buckeye Shielded Cable to any standard 1/2” conduit connection device. The use of Buckeye Shielded Cable (Patent Pending) instead of conduit and corner pulleys for connecting the gas valve, remote pull station, and fusible link line to the Systems Releasing Module reduces installation time by up to 50%. Advanced Automatic Detection The Models BFR-5, BFR-10, BFR-15, and BFR-20 cylinders are designated by flow point capacity (so the BFR5 supports five (5) flow points and so on) instead of the amount of agent they hold. Recharge is available in 5 and 10 flow point containers so there’s never a chance of error. The Buckeye Kitchen Mister System uses reliable Globe ML style fusible links for automatic detection. However, with the Kitchen Mister System no conduit and only one bracket is required in the entire plenum area. Just bring the cable into the plenum through an approved hood penetration, install a terminal bracket on the far end of the hood, and attach the cable. The links are attached directly to the cable without using conduit or brackets, making them quick to install and easy to move. Fusible Link Holders are also available if a continuous fusible link line is desired. BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 17 FOAM CONCENTRATES AND EQUIPMENT FEATURES and SERVICES: • The widest selection of earth-friendly fire fighting foam concentrates in the industry. • Independent tests have shown Buckeye foam concentrates to be superior in quality and performance. • Wide array of foam producing hardware and components designed to maximize foam effectiveness. • Staff of experienced sales technicians to help you choose the right foam, application equipment, and design for your foam system. • Buckeye Fire Equipment can provide assistance for system testing/maintenance and emergency repair service. • In-house laboratory staffed with knowledgeable quality specialists to perform analysis of both Buckeye and competitor foams as required by NFPA 11 and other foam codes. FOAM CONCENTRATES Part Number Foam Concentrate Listing/Approval BFC-1.1 BFC-3.1 BFC-6.1 BFC-33.1 BFC-36.1 BFC-3LT BFC-36LT BFC-CA.1 BFC-HX BFC-3MS BFC-3P BFC-6P BFC-3FP BFC-6FP BFC-BE BFC-VF Platinum 1% AFFF Platinum 3% AFFF Platinum 6% AFFF Platinum 3%x3% AR-AFFF Platinum 3%x6% AR-AFFF 3% Low Temperature AFFF 3%-6% Low Temperature AR-AFFF Platinum Class A 2.2% High-Expansion 3% Mil Spec AFFF 3% Protein 6% Protein 3% Fluoroprotein 6% Fluoroprotein Bug-Eye 3% AR-AFFF Virtual Foam Underwriters Laboratories Underwriters Laboratories Underwriters Laboratories Underwriters Laboratories Underwriters Laboratories Buckeye Quality Assurance Buckeye Quality Assurance USDA Forest Service QPL Underwriters Laboratories U.S. Navy QPL U.K. Min Def 42-22 U.K. Min Def 42-22 Underwriters Laboratories Underwriters Laboratories Underwriters Laboratories Buckeye Quality Assurance FOAM EQUIPMENT Buckeye Fire Equipment manufactures a complete line of components that work in conjunction with the foam concentrates to make an unbeatable fire-fighting combination. The selection includes bladder tanks, pump skids, proportioners, eductors, monitors, foam chambers, foam makers, high expansion generators, foam carts, and handline nozzles. Many of the components can be customized to provide optimal protection for your unique situation. All foam system components are precision made from rugged materials to provide years of dependable service. Whether it’s a complex engineered system or portable equipment, Buckeye Fire Equipment has the components you need to protect your valuable assets. BuckeyeCOMPLETE:Layout 1 5/25/07 11:03 AM Page 18 MOUNTING HARDWARE Buckeye Fire Equipment manufactures strong and durable mounting hardware for all of our portable fire extinguishers. The charts below show the corresponding mounting hardware for the extinguishers. MARINE/VEHICLE BRACKETS 700287 700270 700260 700430 700226 700228 700229 700230 Part No. Model Typical Extinguisher Sizes Used For Reference Diameter 700287 700270 700260 700430 700226 700228 700229 700230 A-2 A-6 B-6 B-12 809 810 811 812 All 2.5 lb. dry chemical and Halotron™ All 5 lb. & 5.5 lb. dry chemical and Halotron™ All 5 lb. & 5.5 lb. dry chemical and Halotron™ 10 Tall dry chemical 10 Tall dry chemical and 5 lb. CO² 10 lb. & 15 lb. CO², 11 lb. & 15 lb. Halotron 20S lb. and 30S lb. dry chemical, 20 lb. CO², Class D 10S dry chemical 3.375 in. 4.25 in 4.25 in. 5.125 in. 5.0 in. – 5.25 in. 6.5 in. – 7.25 in. 7.0 in. – 8.0 in. 6.0 in. – 6.25 in. WALL HOOKS 700202 700204 700203 700249 700247 900935 900937 Part No. Typical Extinguisher Sizes Used For Reference Diameter 700202 700203 700204 700247 2.5 lb., 5 lb., and 5.5 lb. dry chemical and Halotron™ 10 Tall & 5 lb. CO2 10 Short dry chemical 20 Short & 30 Short dry chemical, 10 & 15 lb. CO2, and 11 & 15 lb. Halotron™ 20 lb. CO2 Wet Chemical and Water Water Mist 3.25 in. – 4.25 in. 4.75 in. – 5.5 in. 5.0 in. – 6.5 in. 6.75 in. – 7.5 in. 700249 900935 900937 (Stainless Steel) 7.5 in. – 8.0 in. 7.0 in. 7.0 in. BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 19 Buckeye Fire Equipment BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 20 Buckeye Fire Equipment 110 Kings Road • Kings Mountain, NC 28086 Dry Chemical Ph: 704.739.7415 Fax: 704.739.7418 www.buckeyef.com Portable and Wheeled Extinguishers Specialty Extinguisher Class “D” & “K” Water / Water Mist Foam Concentrates And Hardware Restaurant Fire Systems UL-300 Listed Carbon Dioxide For More Information Please Contact: Portable and Wheeled Extinguishers Halotron™ 1 Portable and Wheeled Extinguishers