Buckeye Fire Equipment

Transcription

Buckeye Fire Equipment
BuckeyeCOMPLETE:Layout 1
5/24/07
4:06 PM
Page 1
BUCKEYE FIRE EQUIPMENT
American Made
Since 1968
2007 Fire Equipment
Product Catalog
www.buckeyef.com
BuckeyeCOMPLETE:Layout 1
5/24/07
4:06 PM
Page 2
Company and Product Profile
Buckeye Fire Equipment
A Tradition of Innovation and
Reliability
In the fire protection industry for over 35 years,
the Buckeye Fire Equipment Company is an
innovative manufacturer of a complete line of
Underwriters Laboratories (UL) Listed fire
protection products:
•
•
•
•
Portable and wheeled fire extinguishers
Dry chemical extinguishing agents
Firefighting foam concentrates and foam
hardware
Engineered restaurant fire suppression
systems
At our 165,000 square foot manufacturing
facility located near Charlotte, North Carolina,
Buckeye Fire Equipment produces high quality
and reliable fire protection equipment for
national and international markets. With sales
and warehouse centers strategically located
throughout the United States, as well as a global
network of authorized distributors, Buckeye Fire
Equipment is ready to provide its customers with
timely and efficient sales, delivery, and service.
Fire Extinguishers
Portable Hand and Wheeled
At the heart of the Buckeye Fire Equipment
product lines are the hand-portable dry chemical
fire extinguishers. The performance reliability of
these extinguishers is a direct result of the
stringent controls under which each component
is produced.
We mill and blend our own dry chemical agents
(monoammonium phosphate based [ABC],
potassium bicarbonate based [Purple K], and
sodium bicarbonate based [Standard]) on site
where each batch is tested and verified to meet
our in-house and UL quality requirements. In our
machining centers we produce our cylinders and
valve component parts to exacting standards that
are quality-assured by a manufacturing and
inspection system certified to the latest revision
of the ISO 9001 Quality Standard. On one of the
most modern automated process lines in the
world, the extinguishers are filled, pressurized,
and leak tested to assure that only the highest
quality extinguishers reach our customers.
ABC Fire Extinguisher at Work
Buckeye Fire Equipment also manufactures a
wide selection of hazard specific fire
extinguishers to meet your individual fire
protection needs. These include clean gas
extinguishers such as Carbon Dioxide and
Halotron™, the Class K Wet Chemical
extinguishers used for kitchen fire suppression,
Class D extinguishers for use on metal fires, and
the Water Mist extinguishers suitable for use on
Class A fires where a Class C hazard may also
exist.
BuckeyeCOMPLETE
5/24/07
4:53 PM
Page 3
If your situation requires more fire-stopping
power, Buckeye offers clean gas agents and all
three of our dry chemical agents in easily
transportable wheeled units. Depending on the
extinguishing agent you select, these wheeled
units are available in capacities ranging from 50
lbs. to 350 lbs. Please refer to the Catalogue
Product Tables for the models and sizes offered.
Buckeye Kitchen Mister
UL 300 Restaurant
Fire Suppression System
Firefighting Foams and Hardware
With one of the world’s largest capacity foam
blending operations, Buckeye Fire Equipment
produces a comprehensive line of firefighting
foam
concentrates
recognized
through
independent tests as among the best in the
industry.
Our wide array of foam concentrates assures that
there is one designed to meet your fire
suppression requirements.
As committed as we are to the quality and
performance of our foam concentrates, we are
also committed to protecting the environment our foam concentrates are manufactured without
any EPA reportable components.
Buckeye Fire Equipment is proud to introduce
the next generation of UL-300 Restaurant
Cooking Area Fire Suppression Systems, the
Buckeye Kitchen Mister Suppression System.
Although many restaurant systems brag about
product innovation, improved technology, fire
fighting ability, and “ease of installation”, the
Buckeye Kitchen Mister is the first product to
truly deliver on that promise.
By combining the fire fighting ability of misting
technology, common sense features, and time
saving patented innovations, the Kitchen Mister
makes all other systems seem complicated and
outdated.
If reducing installation time by up to 50% is
important to you, then your system has arrived.
Knocking Down the Fire with
Buckeye Foam
To complement the firefighting foam product
line, Buckeye Fire Equipment manufactures
foam storage, proportioning, and delivery
hardware that can be engineered for your specific
needs. This hardware may be used in both fixed
or portable system installations. Our expert
technical staff can assist you in determining the
most effective application for your potential
hazard.
Buckeye Fire Equipment
Research and Development Center
Customer Driven to Serve You
Buckeye Fire Equipment is a customer driven
company that prides itself on earning your
business with every call. If you have questions
about any of the products in this catalogue please
do not hesitate to contact us.
BuckeyeCOMPLETE:Layout 1
5/24/07
4:07 PM
Page 4
Portable Extinguisher
Selection Guide
The National Fire Protection Association
(NFPA) has established the requirements for
the number, size, placement, performance,
and
maintenance
of
portable
fire
extinguishers. These requirements are
contained in NFPA 10, “Standard for
Portable Fire Extinguishers”. Within this
Standard it is stated that the selection of fire
extinguishers for a given situation is
determined by the character of the fires
anticipated to be encountered, the
construction and occupancy of the property
to be protected, the ambient temperature of
the area where the extinguisher will be
located, and other factors that may dictate
the selection of a particular type of
extinguisher.
CLASSIFICATION
Generally, fire extinguishers are selected
based on the hazard(s) they are intended to
protect.
Classifications
have
been
established to categorize what type of
extinguishing agent is best suited for the fire
hazard. These classifications are A, B, C, D,
and K.
A fire extinguisher assigned a Class A
classification is suitable for use on ordinary
combustibles; wood, paper, cloth, rubber,
and many of the plastics. The B
classification is intended for use on
flammable liquids, combustible liquids,
petroleum greases, oils, oil-based paints,
solvents, alcohols, and flammable gases.
Class C extinguishers are for use on fires
involving energized electrical equipment.
For fires involving combustible metals
(magnesium, lithium, zirconium, etc.), Class
D extinguishers are best to use. An
extinguisher designated Class K best
protects cooking appliances that utilize
cooking media such as vegetable oils and
animal fats.
RATING
Along with the classification, the numerical
rating of an extinguisher is an important
factor in the proper selection of an
extinguisher. The rating is a measure of the
extinguishing potential of the fire
extinguisher and is developed on the basis of
comparative fire tests (Reference UL 711,
Standard for Rating and Testing of Fire
Extinguishers). Only the Class A and Class
B classifications carry numerical ratings.
Basically, the higher the number associated
with the classification letter, the larger the
fire the extinguisher has the potential to put
out. Please refer to NFPA 10 when
determining the rating necessary for the
floor area requiring protection.
There are no numerical ratings associated
with Class C, D, or K classifications.
Comparative fire tests are not conducted. In
the case of Class C, the electrical
nonconducting characteristics of the agent
are verified, not the extinguishing potential.
For Class D, only the amount of agent and
application method needed to control a
metal fire of a certain size and type is tested.
And for Class K, the fire extinguishing
characteristics of the extinguisher have only
been determined for a single size fire source.
In the typical rating of an extinguisher, for
example 3A-40B:C, the 3 and the 40
indicate the extinguishing potential of the
unit for a Class A and Class B fire
respectively. The C indicates that the
extinguishing agent will not conduct
electricity, preventing shock to the user if
used on energized electrical equipment.
On the following page is a reference chart
with the basic rating parameters for
extinguishers.
SUMMARY
To provide the best protection of life and
property from the destructive force of fire, it
is critical that the proper fire extinguisher
selection be made. The Classification and
Rating of an extinguisher are vital pieces of
information for making that selection.
Using NFPA 10 for guidance, matching the
right fire extinguisher to the potential
hazard, providing a sufficient number of
extinguishers for the area to be protected,
locating the extinguishers for maximum
visibility and accessibility, and personnel
trained in the use and maintenance of the
extinguisher will significantly lessen the risk
of loss.
BuckeyeCOMPLETE:Layout 1
5/24/07
4:07 PM
Page 5
EXTINGUISHER PLACEMENT
AND RATING REFERENCE CHARTS
Placement/Accessibility Of Extinguisher
CLASS A
FIRE HAZARD
MAXIMUM
TRAVEL
DISTANCE
CLASS B
FIRE HAZARD
75 Feet
50 Feet
Maximum area that one
extinguisher can protect
and meet the 75’ rule
= 11,250 sq. ft.
Maximum area that one
extinguisher can protect
and meet the 50’ rule
= 5000 sq. ft.
CLASS C
FIRE HAZARD
CLASS D
FIRE HAZARD
CLASS K
FIRE HAZARD
In accordance with
the Class A or B
hazard it is protecting
75 Feet
Maximum area that one
extinguisher can protect
and meet the 30’ rule
= 1800 sq. ft.
30 Feet
Basic Extinguisher Rating Parameters
Numerical
Rating
1A
2A
3A
4A
6A
10A
20A
30A
40A
ORDINARY COMBUSTIBLES
FLAMMABLE LIQUIDS
Class A Fires
(Wood, Paper, Cloth, Rubber)
Class B Fires
(Gasoline, Oil, Paints, Solvents, Propane)
Wood
Panel
Fire Test
8’x 8’
10’x 10’
12’x 12’
14’x 14’
17’x 17’
N/A
N/A
N/A
N/A
Wood Crib Fire Test
Overall Dims.
(inches)
20 x 20 x 18
25 x 25 x 24
29 x 29 x 27
32 x 32 x 30
36 x 36 x 34.5
43 x 43 x 40.5
55 x 55 x 57.5
64 x 64 x 64.5
69 x 69 x 71.5
No. of
Members
72
112
144
180
230
324
256
324
400
Trade Size of
Members (inches)
2 x 2 x 20
2 x 2 x 25
2 x 2 x 29
2 x 2 x 32
2 x 2 x 36
2 x 2 x 43
2 x 4 x 55
2 x 4 x 64
2 x 4 x 69
Numerical
Rating
2B
5B
10B
20B
40B
60B
80B
120B
160B
Minimum
Discharge
Required
8 Sec
8* Sec
8* Sec
8* sec
13 Sec
17 Sec
20 Sec
26 Sec
31 Sec
*13 Seconds
with an “A” rating
Fire Test
Pan Size
(expert)
Estimated
Novice
Capability
5 sq ft
12.5 sq ft
25 sq ft
50 sq ft
100 sq ft
150 sq ft
200 sq ft
300 sq ft
400 sq ft
5 sq ft
10 sq ft
20 sq ft
40 sq ft
60 sq ft
80 sq ft
80 sq ft
120 sq ft
160 sq ft
ENERGIZED
ELECTRICAL
COOKING
MEDIA
Class C Fires
(Computers,
Electrical Panels,
Transformers)
Class K Fires
(Cooking
Appliances)
NO FIRE TEST
Fire Test Fryer Size
Extinguishing agent is
tested for electrical
nonconductivity. If
nonconductive, the “C”
symbol is added to the
existing classification.
18”x24”x18”
Deep Fat Fryer
No numerical rating
is given for Class C
No numerical rating
is given for Class K
Discharge Time
Approx. 60 Seconds
There are three general classifications of hazard areas- low, ordinary, and extra.
Minimum rating required for low or ordinary hazard areas is 2A.
Minimum rating for extra hazard areas is 4A.
Maximum floor area that can be protected per unit of A is 3,000 sq. ft. for low hazard.
Maximum floor area that can be protected per unit of A is 1,500 sq. ft. for ordinary hazard.
Maximum floor area that can be protected per unit of A is 1,000 sq. ft. for extra hazard.
To determine the rating necessary for proper protection, divide the total sq. ft. by the unit of A for the hazard.
Example: An extinguisher is needed to protect an office area (low hazard) that measures 10,500 sq. ft.
Total sq. ft. = 10,500. Unit of A for low hazard is 3,000. The rating necessary to protect the area is
10,500 ÷ 3,000 = 3.5 units of A. Rounding up to the next numerical rating would mean that a 4A-rated
extinguisher would be needed to protect the office.
If the area were classified as “extra hazard” then the extinguisher would need to be rated 20A
(10,500 ÷ 1,000 = 10.5 units of A. Rounded up to the next numerical rating = 20A).
BuckeyeCOMPLETE:Layout 1
5/25/07
11:01 AM
Page 6
ABC DRY CHEMICAL
HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:
•
Monoammonium Phosphate based dry chemical agent.
•
Rated for use on “A”, “B”, and “C” class fires. Provides the widest, most practical range of fire protection.
•
Rechargeable
•
Steel cylinders with a baked-on polyester enamel coating stand up to harsh environments.
•
Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards
•
Optional brass valves on some units. 30 lb. unit has brass valve only
TYPICAL USES: Offices, warehouses, woodworking areas, farms, general public assembly areas, and homes. The ABC extinguisher
is not recommended for use on sensitive electronic equipment or aircraft structure.
Model
Part #
Alum. Valve
Part #
Brass Valve
Agent
Capacity
UL Rating
Discharge Time
Range (ft/m)
Operating
Pressure
Bracket
USCG Approval
Ship Wt.
Height
Width
Diameter
2.5 ABC
V/B
5 ABC
5 ABC
V/B
10 TALL
ABC
10S ABC
20S ABC
30S ABC
13315
10914
25614
11340
11310
12120
N/A
N/A
2.5 lb.
(1.13 kg)
1A-10B:C
9 sec
9-15 / 2.7-4.6
100 psi
(689 kPa)
Vehicle
10915
25615
11341
N/A
12121
20 lb.
(9.07 kg)
20A-120B:C
26 sec
12905
30 lb.
(13.6 kg)
20A-160B:C
32 sec
25-30 / 7.6-9.1
5 lb.
(2.27 kg)
3A-40B:C
14 sec
12-18 / 3.7-5.5
Wall
10 lb.
(4.54 kg)
4A-80B:C
4A-60B:C
22 sec
18 sec
15-21 / 4.6-6.4
195 psi
(1344 kPa)
Vehicle
Type B:C Size I
Type A Size II
Type B:C Size I
5.5 lbs.
(2.5 kg)
14.75 in
(37.5 cm)
4.875 in
(12.4 cm)
3.375 in
(8.6 cm)
10 lbs.
10.25 lbs
(4.5 kg)
(4.7 kg)
16.375 in
(41.6 cm)
7.25 in
(18.4 cm)
4.25 in
(10.8 cm)
Wall
Type A Size II
Type B:C Size II
18.25 lbs.
(8.3 kg)
21 in
(53.3 cm)
7.75 in
(19.7 cm)
5.125 in
(13 cm)
18.75 lbs.
(8.6 kg)
16.75 in
(42.5 cm)
8.25 in
(21 cm)
6 in
(15.2 cm)
Type A Size II
Type B:C Size III
Type A Size II
Type B:C Size IV
33.5 lbs.
(15.2 kg)
21.25 in
(53.8 cm)
52.25 lbs.
(23.7 kg)
27.375 in
(69.4 cm)
8.75 in
(22.2 cm)
7.5 in
(19.1 cm)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:01 AM
Page 7
STANDARD DRY CHEMICAL
HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:
•
Sodium Bicarbonate based dry chemical agent.
•
Rated for use on “B” and “C” Class fires.
•
Rechargeable
•
Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.
•
Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.
TYPICAL USES: Kitchens, garages, boats, vehicles, and extinguisher use training.
The Standard extinguisher is not recommended for use on sensitive electronic equipment.
Model
Part # Aluminum Valve
Agent
Capacity
UL Rating
Discharge Time
Range
Operating
Pressure
Bracket
USCG Approval
Ship Wt.
Height
Width
Diameter
2.5 STD V/B
13415
2.5 lbs.
(1.13 kg)
10 B:C
9 seconds
9-15 ft
(2.7-4.6 m)
100 psi
(689 kPa)
Vehicle
5.5 STD
11014
5.5 STD V/B
13514
5.5 lbs.
(2.50 kg)
40 B:C
14 seconds
12-18 ft
(3.7-5.5 m)
20S STD
12220
20 lbs.
(9.07 kg)
120 B:C
26 seconds
15-21 ft
(4.6-6.4 m)
195 psi
(1344 kPa)
Wall
Vehicle
Type B:C Size I
5.5 lbs.
(2.5 kg)
14.75 in
(37.5 cm)
4.875 in
(12.4 cm)
3.375 in
(8.6 cm)
10 STD
11840
10 lbs.
(4.54 kg)
10.5 lbs.
10.75 lbs.
(4.8 kg)
(4.9 kg)
16.375 in
(41.6 cm)
7.25 in
(18.4 cm)
4.25 in
(10.8 cm)
Wall
Type B:C Size II
Type B:C Size III
18.25 lbs.
(8.3 kg)
21 in
(53.3 cm)
7.75 in
(19.7 cm)
5.125 in
(13 cm)
33.5 lbs.
(15.2 kg)
21.25 in
(53.8 cm)
8.75 in
(22.2 cm)
7.5 in
(19.1 cm)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:01 AM
Page 8
PURPLE K DRY CHEMICAL
HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:
•
Potassium Bicarbonate based dry chemical agent.
•
Rated for use on “B”, and “C” class fires. Most effective dry chemical agent for Class B fires
•
Rechargeable
•
Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.
•
Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards
•
Optional brass valves on some units. 30 lb. unit has brass valve exclusively.
TYPICAL USES: Garages, service bays, boats, vehicles, fuel storage and transfer areas.
The Purple K extinguisher is not recommended for use on sensitive electronic equipment.
Model
Part #
Alum. Valve
Part #
Brass Valve
Agent
Capacity
UL Rating
Discharge
Time
Range
Operating
Pressure
Bracket
USCG
Approval
Ship Wt.
Height
Width
Diameter
2.5 PK V/B
13515
5 PK
11214
5 PK V/B
25914
10 PK
11740
20S PK
12620
30S PK
N/A
N/A
N/A
N/A
N/A
12621
12805
10 lbs
(4.54 kg)
80 B:C
22 seconds
20 lbs.
(9.07 kg)
120 B:C
26 seconds
30 lbs.
(13.6 kg)
160 B:C
32 seconds
2.5 lbs
(1.13 kg)
10 B:C
9-15 ft
(2.7-4.6 m)
100 psi
(689 kPa)
Vehicle
5.5 lbs
(2.49 kg)
14.75 in
(37.5 cm)
4.875 in
(12.4 cm)
3.375 in
(8.6 cm)
5 lbs.
(2.27 kg)
20 B:C
9 seconds
12-18 ft
(3.7-5.5 m)
Wall
15-21 ft
(4.6-6.4 m)
195 psi
(1344 kPa)
Vehicle
25-30 ft
(7.6-9.1 m)
Wall
Type B:C Size I
Type B:C Size II
Type B:C Size III
Type B:C Size IV
10 lbs.
(4.5 kg)
18.25 lbs.
(8.3 kg)
21 in
(53.3 cm)
7.75 in
(19.7 cm)
5.125 in
(13 cm)
33.5 lbs.
(15.2 kg)
21.25 in
(53.8 cm)
52.25 lbs.
(23.7 kg)
27.375 lbs.
(69.4 cm)
10.25 lbs.
(4.6 kg)
16.375 in
(41.6 cm)
7.25 in
(18.4 cm)
4.25 in
(10.8 cm)
8.75 in
(22.2 cm)
7.5 in
(19.1 cm)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 9
HALOTRON™
HAND HELD AND WHEELED
STORED PRESSURE FIRE EXTINGUISHERS
FEATURES:
•
Residue-free Hydrochlorofluorocarbon gas agent pressurized with argon.
•
Excellent replacement for Halon 1211 extinguishers.
•
Rechargeable steel cylinders with baked-on polyester enamel coating that stands up to harsh environments.
Wheeled units have DOT approved 4BW240 cylinders, rugged frames, and semi-pneumatic tires.
•
All units are manufactured to ANSI/UL 2129 and ANSI/UL 711 Standards.
•
Optional chrome-plated brass valves on some units (standard on Wheeled Extinguishers).
TYPICAL USES: Computer rooms, telephone switch rooms, data storage areas, boats, and flight lines.
Model
2.5F
Part #
Alum. Valve
Part #
Brass Valve
Agent Capacity
70258
2.5F
V/B
70251
Height
Width
Diameter
70259
2.5H
V/B
70256
Not
Available
2.5 lbs
(1.13 kg)
2B:C
UL Rating
Discharge Time
Range
Operating
Pressure
Bracket
USCG
Approval
Ship Wt.
2.5H
5F
5F V/B
5H
5H V/B
11
15
70510
70550
75550
75555
71100
71550
70511
70551
75551
75556
71101
71551
5 lbs.
(2.27 kg)
5.5 lbs.
(2.49 kg)
11 lbs.
(5 kg)
1A-10B:C
5B:C
9 seconds
6-10 ft
(1.8-3 m)
Wall
Vehicle
Wall
Not Applicable
9-15 ft
(2.7-4.5 m)
Vehicle
5.25 lbs
(2.4 kg)
5.5 lbs.
5.75 lbs
(2.49 kg)
(2.6 kg)
13.375 in (34 cm)
5.625 in
6.75 in
(14.3 cm)
(17.1 cm)
3.375 in (8.6 cm)
100 psi
(689 kPa)
Wall
Vehicle
9.25 lbs.
(4.2 kg)
6.5 in
(16.5 cm)
Wall
Type B:C
Size I
9.5 lbs.
10 lbs.
(4.3kg)
(4.5 kg)
16.375 in (41.6 cm)
7.25 in
6.5 in
(18.4 cm)
(16.5 cm)
4.25 in (10.8 cm)
Vehicle
10.25 lbs.
(4.7 kg)
7.25 in
(18.4 cm)
15.5 lbs.
(7.03 kg)
2A-10B:C
13 seconds
12-18 ft
(3.7-5.5 m)
125 psi
(862 kPa)
Wall
Type B:C
Size II
21.25 lbs.
25.75 lbs.
(9.6 kg)
(11.7 kg)
17.5 in (44.5 cm)
8.625 in
(21.9 cm)
7 in (17.8 cm)
Wheeled Extinguishers
Model
Part #
Capacity
W-65
76500
W-150
71500
65 lbs
(29.5 kg)
150 lbs
(68 kg)
UL
Rating
4A-40B:C
10A-80B:C
Discharge
Time
17
seconds
23
seconds
Range
15-25 ft
(4.6-7.6 m)
23-36 ft
(7-10.7 m)
Unit
Height x Width x Depth
50 x 24 x 41.5 in
(127 x 61 x 105 cm)
62 x 24 x 41.5 in
(157.5 x61 x 105 cm)
Hose
Diameter x Length
.75 in x 25 ft
(1.9 cm x 7.6 m)
1 in x 40 ft
(2.5 cm x 12.2 m)
Ship
Weight
300 lbs
(136 kg)
480 lbs
(218 kg)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 10
CARBON DIOXIDE
HAND-HELD AND WHEELED
FIRE EXTINGUISHERS
FEATURES:
•
Residue-free carbon dioxide gas extinguishing agent.
•
Hand-held units use aluminum cylinders with a baked-on polyester enamel coating to withstand harsh
environments.
•
Wheeled units are constructed with spun steel cylinders, rugged frames, and pneumatic tires and are
designed to be easily operated by one person.
•
All units manufactured to ANSI/UL 154 and ANSI/UL 711 Standards and use DOT compliant cylinders.
•
Plated brass valves on both hand-held and wheeled units.
•
Optional tow loops offered on the wheeled extinguishers.
TYPICAL USES: Refineries, shipboard, laboratories, construction sites, chemical plants, and manufacturing
facilities.
Model
Part Number
Agent Capacity
UL Rating
Discharge Time
Range
Bracket
USCG Approval
Ship Wt.
Height
Width
Diameter
5CD
45100
5 lbs. (2.27 kg)
5B:C
8 seconds
Hand-Held Extinguishers
10CD
45600
10 lbs. (4.54 kg)
15CD
20CD
46100
46600
15 lbs. (6.80 kg)
20 lbs. (9.07 kg)
10B:C
10 seconds
15 seconds
20 seconds
4-8 ft (1.2-2.4 m)
Wall
Type B:C Size I
Type B:C Size II
13.75 lbs. (6.3 kg)
27.75 lbs. (12.6 kg)
37.75 lbs. (17.1 kg)
49.0 lbs. (22.2 kg)
17.375 in (44.1 cm)
19.75 in (50.2 cm)
26.375 in. (67 cm)
26.875 in (68.2 cm)
8.25 in (21 cm)
12 in (30.5 cm)
13 in (33 cm)
5.25 in (13.3 cm)
6.89 in (17.5 cm)
8 in (20.3 cm)
Wheeled Extinguishers
Model
Part #
Capacity
C-50-SE
35050
C-100-SE
35100
50 lbs.
(22.68 kg)
100 lbs.
(45.36 kg)
UL
Rating
20B:C
Discharge
Time
40
seconds
80
seconds
Range
15 ft
(4.6m)
Unit
Height x Width x Depth
60 x 30 x 21 in
(152.4 x 76.2 x 53.3 cm)
65 x 30 x 21 in
(165.1 x 76.2 x 53.3 cm)
Hose
Dia x Length
1 in x 15 ft
(2.5 cm x 4.56 m)
1 in x 40 ft
(2.5 cm x 12.2 m)
Ship
Weight
250 lbs.
(113.4 kg)
390 lbs.
(176.9 kg)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 11
AUTOMATIC SPOT
PROTECTION
FEATURES:
•
Designed to provide supplemental protection suitable for some local and total flood applications.
•
Two mount styles available, charged with multipurpose dry chemical (ABC) or clean agent Halotron™.
•
The cylinders are constructed and tested to the same engineering standards as our portable extinguishers.
•
These units are not Underwriters Laboratories Listed and are not intended for use in lieu of an engineered
system. They are not to be multiple mounted.
VERTICAL MOUNT STYLE
Agent
Part No.
Capacity (lb./kg)
Ship Wt. (lb./kg)
Operating Pressure
Length
Diameter
Max Total FloodVolume
Max Total FloodHeight above Hazard
Local Application
Coverage Areas
Multipurpose ABC Dry Chemical
80250
80501
81001
82001
2.5 lbs/ 1.13 kg
5 lbs/ 2.3 kg
10 lbs/ 4.5 kg
20 lbs/ 9.1 kg
4 lbs/ 1.8 kg
11 lbs/ 5.0 kg
19 lbs/ 8.6 kg
36 lbs/ 16.3 kg
100 psi (689 kPa)
195 psi (1344 kPa)
15.25 in
17.25 in
17.625 in
21.875 in
3.375 in
4.25 in
6.0 in
7.5 in
120 cu ft
180 cu ft
7.5 ft
4 ft x 4 ft
4 ft x 6 ft
Halotron™
87100
87200
18 lbs/ 8.2 kg
25 lbs/ 11.3 kg
29 lbs/ 13.2 kg
42 lbs/ 19.0 kg
100 psi (689 kPa)
17.875 in
21.875 in
7.0 in
7.5 in
1300 cu ft
2184 cu ft
500 cu ft
700 cu ft
13 ft
14 ft
8 ft
10 ft
10 ft x 10 ft
12 ft x 13 ft
4 ft x 4 ft
6 ft x 6 ft
Max Local Application- Height Above Hazard = 4 feet for all models
HORIZONTAL MOUNT STYLE
Agent
Part No.
Capacity (lb./kg)
Ship Wt. (lb./kg)
Operating Pressure
Length
Diameter
Max Total FloodVolume
Max Total FloodHeight above Hazard
Local Application
Coverage Areas
Mounting Bracket
Multipurpose ABC dry chemical
80251
80521
81021
82021
2.5 lbs/ 1.13 kg
5 lbs/ 2.3 kg
10 lbs/ 4.5 kg
20 lbs/ 9.1 kg
4 lbs/ 1.8 kg
11 lbs/ 5.0 kg
19 lbs/ 8.6 kg
36 lbs/ 16.3 kg
100 psi (689 kPa)
195 psi (1344 kPa)
14.25 in
17.25 in
20.875 in
21.875 in
3.375 in
4.25 in
5.125 in
7.5 in
120 cu ft
180 cu ft
7.5 ft
Halotron™
87105
87205
18 lbs/ 8.2 kg
25 lbs/11.3 kg
29 lbs/ 13.2 kg
42 lbs/ 19.0 kg
100 psi (689 kPa)
17.875 in
21.875 in
7.0 in
7.5 in
1300 cu ft
2184 cu ft
500 cu ft
700 cu ft
13 ft
14 ft
8 ft
10 ft
4 ft x 4 ft
4 ft x 6 ft
10 ft x 10 ft
12 ft x 13 ft
4 ft x 4 ft
6 ft x 6 ft
700287
700270
700226
700229
700228
700229
Max Local Application- Height Above Hazard = 4 feet for all models
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 12
DRY CHEMICAL
WHEELED FIRE EXTINGUISHERS
FEATURES:
•
•
•
•
•
•
•
•
•
Three choices in dry chemical agents are available to suit your particular fire protection needs:
Monoammonium Phosphate (ABC), Sodium Bicarbonate (Standard), and Potassium Bicarbonate (Purple K).
The ABC extinguisher is rated for use on “A”, “B”, and “C” class fires, providing the widest, most practical
range of fire protection. The Standard and Purple K extinguishers are rated for use on B:C classes of fires.
Designed for one-man operation. Easily transported through doorways and over rough terrain.
All models are also available as stationary units.
Every model is rechargeable.
Rugged steel cylinders and frames with baked-on polyester enamel coatings stand up to harsh environments.
Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.
Plated brass cylinder valves and hose valve assemblies.
All pressurized cylinders are DOT approved. Extinguishers part numbered 30010, 30110, 30030, 30310, &
31210 are USCG approved.
TYPICAL USES: Offshore rigs, ship docks, refineries, chemical plants, aircraft ramps, remote construction sites, large
laboratories, processing plants, storage and loading areas.
These extinguishers are not recommended for use on sensitive electronic equipment.
WHEELED EXTINGUISHER PHYSICAL ATTRIBUTES
MODEL
PART
NO.
SHIP
WEIGHT
HEIGHT
WIDTH
DEPTH
HOSE
LENGTH x DIA
WHEEL
DIAMETER
A-50-SP
30010
K-50-SP
30030
193 lbs.
(88 kg)
47 inches
(119 cm)
24 inches
(61 cm)
26.5 inches
(67 cm)
25 ft. x .50 in
(7.6 m x 1.3 cm)
12.3 x 3.5 in
(31.3 x 8.9 cm)
A-150-SP
K-150-SP
A-150-RG
K-150-RG
30110
30310
31120
31320
343 lbs.
(156 kg)
51 inches
(128 cm)
26 inches
(66 cm)
38 inches
(96.5 cm)
S-150-RG
31220
413 lbs.
(188 kg)
438 lbs.
(199 kg)
50 inches
(127 cm)
24 inches
(61 cm)
42 inches
(105 cm)
A-150-RG
A-150-PT
31140*
31150**
31340*
31350**
31240*
31250**
31110
K-150-PT
31310
S-150-PT
31210
K-150-RG
S-150-RG
A-350-RG
K-350-RG
S-350-RG
A-350-PT
K-350-PT
S-350-PT
32120*
32140**
32320*
32340**
32220*
32240**
32110*
32130**
32310*
32330**
32210*
32230**
448 lbs.
(204 kg)
55 inches
(139 cm)
32 inches
(81.3 cm)
46 inches
(117 cm)
16 x 4 in
(40.6 x 10.2 cm)
50 ft x .75 in
(15.2 m x 1.9 cm)
50 inches
(127 cm)
24 inches
(61 cm)
42 inches
(105 cm)
16 x 4 in
(40.6 x 10.2 cm)
810 lbs.
(368 kg)
860 lbs.
(391 kg)
700 lbs.
(318 kg)
750 lbs.
(341 kg)
* Steel Wheels
** Steel wheels with
rubber tread
473 lbs.
(215 kg)
345 lbs.
(157 kg)
370 lbs.
(168 kg)
36 x 2.5 in
(91.4 x 6.4 cm)
36 x 2.5 in
(91.4 x 6.4 cm)
* Steel Wheels
58 inches
(147 cm)
36 inches
(91.4 cm)
48 inches
(122 cm)
50 ft x 1 in
(15.2 m x 2.5 cm)
** Steel wheels with
rubber tread
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 13
ABC WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS
MODEL
PART NO.
AGENT CAPACITY
UL RATING
DISCHARGE
TIME
A-50-SP
30010
50 lbs.
(22.7 kg)
30A-160B:C
35 seconds
A-150-SP
30110
31120
31140
31150
31110
32120
32140
32110
32130
A-150-RG
A-150-PT
A-350-RG
A-350-PT
DISCHARGE
RANGE
25-35 ft
(7.6-10.7 m)
47 seconds
125 lbs.
(56.7 kg)
40A-240B:C
43 seconds
45 seconds
300 lbs.
(136 kg)
40A-320B:C
30-40 ft
(9.1-12.2 m)
53 seconds
57 seconds
PURPLE K WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS
MODEL
PART NO.
AGENT CAPACITY
UL RATING
DISCHARGE
TIME
K-50-SP
30030
50 lbs.
(22.7 kg)
160 B:C
34 seconds
K-150-SP
30310
31320
31340
31350
31310
32320
32340
32310
K-150-RG
K-150-PT
K-350-RG
K-350-PT
DISCHARGE
RANGE
25-35 ft
(7.6-10.7 m)
54 seconds
125 lbs.
(56.7 kg)
57 seconds
320B:C
54 seconds
30-40 ft
(9.1-12.2 m)
56 seconds
300 lbs.
(136 kg)
58 seconds
32330
STANDARD WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS
MODEL
S-150-RG
S-150-PT
S-350-RG
S-350-PT
PART NO.
31220
31240
31250
31210
32220
32240
32210
32230
AGENT CAPACITY
UL RATING
DISCHARGE
TIME
150 lbs.
(68 kg)
240B:C
48 seconds
43 seconds
350 lbs.
(159 kg)
59 seconds
320B:C
50 seconds
DISCHARGE
RANGE
30-40 ft
(9.1-12.2 m)
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 14
SPECIALTY
FIRE EXTINGUISHERS
WET CHEMICAL – CLASS K
•
Contains a blend of Potassium Acetate and Potassium Citrate that is extremely effective
in suppressing high temperature fires fueled by the unsaturated cooking oils used in
today’s restaurant appliances. The agent is applied by a misting discharge nozzle that
prevents the splashing and spreading of the oils. This extinguisher is designed to
complement existing pre-engineered hood systems. Also carries an “A” Rating.
•
Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model
Part #
Agent Capacity
UL Rating
Discharge Time
Operating Pressure
Bracket
Ship Wt.
Height
Width (including hose)
Cylinder Diameter
Construction
WC-6 Liter
50006
6 Liter (1.59 gallons)
1-A:K (Tested to extinguish one 18” X 24” fryer)
54 seconds
100 psi (689 kPa)
Wall
22 lbs. (10 kg)
19.25 inches (48.9 cm)
9 inches (22.9 cm)
7 inches (17.8 cm)
Stainless steel cylinder with plated brass valve
WATER
•
Uses water as the extinguishing agent. This economical and environmentally friendly
extinguisher is ideal for schools, theaters, retail storerooms, and anywhere Class A
hazards exist.
•
Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model
Part #
Agent Capacity
UL Rating
Discharge Time
Operating Pressure
Bracket
Ship Wt. (empty)
Height
Width (including hose)
Cylinder Diameter
Construction
500
50000
2.5 gallon (9.6 liters)
2A
50 seconds
100 psi (689 kPa)
Wall
7.75 lbs. (3.5 kg)
24.5 inches (62.2 cm)
9 inches (22.9 cm)
7 inches (17.8 cm)
Stainless steel cylinder with plated brass valve
BuckeyeCOMPLETE:Layout 1
5/25/07
11:02 AM
Page 15
SPECIALTY
FIRE EXTINGUISHERS
WATER MIST
•
Uses deionized water as the extinguishing agent. The unique misting nozzle creates a fine
water spray that improves the cooling and soaking characteristics of the agent and limits
the scattering of burning material. This extinguisher is the right choice for Class A fires
where there is a potential for Class C (electrical) safety hazards. Ideal for hospitals, clean
rooms, and telecom facilities. The non-magnetic properties of the extinguisher make it
perfect for use in proximity to MRI equipment.
•
Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.
Model
Part #
Agent Capacity
UL Rating
Discharge Time
Operating Pressure
Bracket
Ship Wt.
Height
Width (including hose)
Cylinder Diameter
Construction
WM250
51000
2.5 gallon (9.6 liters)
2A:C
73 seconds
100 psi (689 kPa)
Wall
29.5 lbs. (13.4 kg)
28 inches (71.1 cm)
14 in (35.6 cm)
7 inches (17.8 cm)
Stainless steel cylinder with plated brass valve
COMBUSTIBLE METALS – CLASS D
•
Specially designed for use on combustible metals fires, this extinguisher features a
discharge assembly that keeps the operator at a safe distance while providing accurate
application of the agent on the fire. From the heat of the fire, the sodium chloride based
agent forms a crust to exclude air from the burning material.
•
Manufactured to Factory Mutual standards.
Model
Part #
Agent Capacity
FM Rating
Discharge Time
Operating Pressure
Bracket
Ship Wt.
Height (with hose)
Width (with hose)
Cylinder Diameter
Construction
30D
52100
30 lbs. (13.6 kg)
D
28 seconds
195 psi (1344 kPa)
Wall
55 lbs. ( 24.95 kg)
33 inches (83.8 cm)
16 inches (40.6 cm)
8 inches (20.3 cm)
Steel Cylinder
BuckeyeCOMPLETE:Layout 1
5/24/07
4:08 PM
Page 16
Buckeye Kitchen Mister
UL 300 Restaurant Fire Suppression System
Protect Your Business With
The Best!
Discharge Nozzles
All five (5) Kitchen Mister
nozzles come equipped with a
color identification band, red,
blue, green, white, and
yellow. This allows for easy
identification of the nozzle
even when it’s installed in
difficult locations such as a
duct or plenum area. The
nozzle is also stamped with its
Model Number.
System Releasing Module
Protecting the modern commercial kitchen from the ever
present danger of fire is the reason Buckeye Fire Equipment
designed the Kitchen Mister Fire System. Utilizing state of
the art misting technology, the Kitchen Mister System
extinguishes potentially deadly kitchen fires quicker and
more effectively than any other kitchen system ever
developed, period.
The modern commercial kitchen, with its open flames, hot
surfaces, and grease laden environment combine all the
elements necessary for a fire. Extinguishing fires quickly,
before they can spread, is the best way to limit fire damage
and get your operation back in business.
Don’t Take Chances, Demand The Best!
Simple is Better
The constant changes and complicated requirements of most
restaurant cooking systems have made design and
installation errors a concern for Fire Equipment Distributors
everywhere. Obviously, a simple system design reduces the
possibility of design and installation errors. At Buckeye we’ve
listened to these concerns and understand that simple is
better. One look at the Kitchen Mister and you can see what
a difference common sense makes:
System Cylinders
The System Releasing
Module
has
been
designed
with
a
viewing window to
assure
that
the
actuation cartridge has
been properly installed
and to see the date
written
on
the
cartridge.
It
also
includes high quality
ratchets that allow the gas valve to be opened and tested
from the SRM. The unit can be mounted directly on a
cylinder or can be mounted remotely. It can actuate up to
five (5) agent cylinders and does not require a bracket for
wall mounting.
Buckeye Shielded Cable
The Kitchen Mister
Shielded
Cable
Interface is used to
connect
Buckeye
Shielded Cable to any
standard 1/2” conduit
connection
device.
The use of Buckeye
Shielded Cable (Patent
Pending) instead of conduit and corner pulleys for
connecting the gas valve, remote pull station, and fusible
link line to the Systems Releasing Module reduces
installation time by up to 50%.
Advanced Automatic Detection
The Models BFR-5, BFR-10, BFR-15, and BFR-20
cylinders are designated by flow point capacity (so the BFR5 supports five (5) flow points and so on) instead of the
amount of agent they hold. Recharge is available in 5 and
10 flow point containers so there’s never a chance of error.
The Buckeye Kitchen Mister System uses reliable Globe ML
style fusible links for automatic detection. However, with
the Kitchen Mister System no conduit and only one bracket
is required in the entire plenum area. Just bring the cable
into the plenum through an approved hood penetration,
install a terminal bracket on the far end of the hood, and
attach the cable. The links are attached directly to the cable
without using conduit or brackets, making them quick to
install and easy to move. Fusible Link Holders are also
available if a continuous fusible link line is desired.
BuckeyeCOMPLETE:Layout 1
5/24/07
4:08 PM
Page 17
FOAM CONCENTRATES
AND
EQUIPMENT
FEATURES and SERVICES:
•
The widest selection of earth-friendly fire fighting foam concentrates in the industry.
•
Independent tests have shown Buckeye foam concentrates to be superior in quality and performance.
•
Wide array of foam producing hardware and components designed to maximize foam effectiveness.
•
Staff of experienced sales technicians to help you choose the right foam, application equipment, and design
for your foam system.
•
Buckeye Fire Equipment can provide assistance for system testing/maintenance and emergency repair
service.
•
In-house laboratory staffed with knowledgeable quality specialists to perform analysis of both Buckeye and
competitor foams as required by NFPA 11 and other foam codes.
FOAM CONCENTRATES
Part
Number
Foam
Concentrate
Listing/Approval
BFC-1.1
BFC-3.1
BFC-6.1
BFC-33.1
BFC-36.1
BFC-3LT
BFC-36LT
BFC-CA.1
BFC-HX
BFC-3MS
BFC-3P
BFC-6P
BFC-3FP
BFC-6FP
BFC-BE
BFC-VF
Platinum 1% AFFF
Platinum 3% AFFF
Platinum 6% AFFF
Platinum 3%x3% AR-AFFF
Platinum 3%x6% AR-AFFF
3% Low Temperature AFFF
3%-6% Low Temperature AR-AFFF
Platinum Class A
2.2% High-Expansion
3% Mil Spec AFFF
3% Protein
6% Protein
3% Fluoroprotein
6% Fluoroprotein
Bug-Eye 3% AR-AFFF
Virtual Foam
Underwriters Laboratories
Underwriters Laboratories
Underwriters Laboratories
Underwriters Laboratories
Underwriters Laboratories
Buckeye Quality Assurance
Buckeye Quality Assurance
USDA Forest Service QPL
Underwriters Laboratories
U.S. Navy QPL
U.K. Min Def 42-22
U.K. Min Def 42-22
Underwriters Laboratories
Underwriters Laboratories
Underwriters Laboratories
Buckeye Quality Assurance
FOAM EQUIPMENT
Buckeye Fire Equipment manufactures a complete line of components
that work in conjunction with the foam concentrates to make an
unbeatable fire-fighting combination. The selection includes
bladder tanks, pump skids, proportioners, eductors, monitors,
foam chambers, foam makers, high expansion generators,
foam carts, and handline nozzles. Many of the components can
be customized to provide optimal protection for your unique
situation. All foam system components are precision made from
rugged materials to provide years of dependable service.
Whether it’s a complex engineered system or portable equipment,
Buckeye Fire Equipment has the components you need to protect
your valuable assets.
BuckeyeCOMPLETE:Layout 1
5/25/07
11:03 AM
Page 18
MOUNTING HARDWARE
Buckeye Fire Equipment manufactures strong and durable mounting hardware for all of our portable fire
extinguishers. The charts below show the corresponding mounting hardware for the extinguishers.
MARINE/VEHICLE BRACKETS
700287
700270
700260
700430
700226 700228
700229 700230
Part No.
Model
Typical Extinguisher Sizes Used For
Reference Diameter
700287
700270
700260
700430
700226
700228
700229
700230
A-2
A-6
B-6
B-12
809
810
811
812
All 2.5 lb. dry chemical and Halotron™
All 5 lb. & 5.5 lb. dry chemical and Halotron™
All 5 lb. & 5.5 lb. dry chemical and Halotron™
10 Tall dry chemical
10 Tall dry chemical and 5 lb. CO²
10 lb. & 15 lb. CO², 11 lb. & 15 lb. Halotron
20S lb. and 30S lb. dry chemical, 20 lb. CO², Class D
10S dry chemical
3.375 in.
4.25 in
4.25 in.
5.125 in.
5.0 in. – 5.25 in.
6.5 in. – 7.25 in.
7.0 in. – 8.0 in.
6.0 in. – 6.25 in.
WALL HOOKS
700202
700204
700203
700249
700247
900935
900937
Part No.
Typical Extinguisher Sizes Used For
Reference Diameter
700202
700203
700204
700247
2.5 lb., 5 lb., and 5.5 lb. dry chemical and Halotron™
10 Tall & 5 lb. CO2
10 Short dry chemical
20 Short & 30 Short dry chemical, 10 & 15 lb. CO2,
and 11 & 15 lb. Halotron™
20 lb. CO2
Wet Chemical and Water
Water Mist
3.25 in. – 4.25 in.
4.75 in. – 5.5 in.
5.0 in. – 6.5 in.
6.75 in. – 7.5 in.
700249
900935
900937 (Stainless Steel)
7.5 in. – 8.0 in.
7.0 in.
7.0 in.
BuckeyeCOMPLETE:Layout 1
5/24/07
4:06 PM
Page 19
Buckeye Fire Equipment
BuckeyeCOMPLETE:Layout 1
5/24/07
4:07 PM
Page 20
Buckeye Fire Equipment
110 Kings Road • Kings Mountain, NC 28086
Dry Chemical
Ph: 704.739.7415
Fax: 704.739.7418
www.buckeyef.com
Portable and
Wheeled
Extinguishers
Specialty
Extinguisher
Class “D” & “K”
Water / Water Mist
Foam
Concentrates
And
Hardware
Restaurant Fire
Systems
UL-300 Listed
Carbon Dioxide
For More Information Please Contact:
Portable and
Wheeled
Extinguishers
Halotron™ 1
Portable and
Wheeled
Extinguishers