Time Delay Relays and Modules - catalog 1308242 issued 3/2003
Transcription
Time Delay Relays and Modules - catalog 1308242 issued 3/2003
Catalog 1308242 Issued 3-03 TIME DELAY RELAYS & MODULES Alphanumeric Index Series Type Page AGASTAT Timer Accessories ............................................. 1206 Circuit Breakers ........................ 101-124 1 Transformers.............................. 201-212 2 Low-signal PC Board Relays . 301-336 3 Mid-Range PC Board Relays ....... 19-21 4 Power PC Board Relays ................ 22-35 5 Forcibly-Guided Contacts.............. 36-79 Plug-in/Panel Mount Relays 6 AGASTAT Timer Terms and Definitions ............................. 1204 AGASTAT Timer Timing Modes ......................................... 1205 2100 ..................... Miniature Electropneumatic Timer ...... 1254 7000 ..................... Electropneumatic Timer ...................... 1248 3RP15 ................... Programmable Time Delay Relay ........ 1207 48K ..DISCONTINUED. Programmable Time Delay Relay . 1210 CB ........................ Discrete Function Time Delay Relay ... 1228 CD ........................ Discrete Function Time Delay Relay ... 1222 CG ........................ Discrete Function Time Delay Relay ... 1220 CH ........................ Discrete Function Time Delay Relay ... 1226 CK ......................... Discrete Function Time Delay Relay ... 1224 CL ......................... Discrete Function Time Delay Relay ... 1231 CN1 ...................... Discrete Function Time Delay Relay ... 1219 CNM5 ................... Programmable Time Delay Relay ........ 1215 CNS ...................... Programmable Time Delay Relay ........ 1213 CNT ...................... Programmable Time Delay Relay ........ 1211 CR ........................ Discrete Function Time Delay Relay ... 1230 CU ........................ Discrete Function Time Delay Relay ... 1231 MD0 ..................... Discrete Function Time Delay Relay ... 1233 P&B Time Delay Relay Terms & Definitions ...................... 1202 P&B Time Delay Relay External Resistor Guide ................. 1203 SCB ...................... Discrete Function Time Delay Relay ... 1235 SCE ...................... Discrete Function Time Delay Relay ... 1239 SCF ....................... Programmable Time Delay Relay ........ 1218 SRC ...................... Discrete Function Time Delay Relay ... 1237 SSC ...................... Discrete Function Time Delay Relay ... 1234 SSF ....................... Programmable Time Delay Relay ........ 1217 SST ....................... Discrete Function Time Delay Relay ... 1238 NOTE: In addition to the products listed in this section of the databook, time delay relays are also described in other sections are available with printed circuit board terminals. Relays with Following is a list: MT* .......................................................................... 742 Plug-in/Panel Mount *Relay, socket and module combination. General Purpose Relays............ 701-749 7 Latching, Impulse, Rotary & Special Application Relays TR ............................................................................. 917 Power Relays & Definite 8 Purpose Contactors...................... 89-131 Time delay relays are also included in our line of high performance relays (see overview in section 14 of this databook). Latching, Impulse & Rotary Relays ............................... 149-154 9 Automotive Relays ...................... 141-148 10 Solid State Relays & Input/Output Modules ................ 195-207 11 Time Delay Relays & Modules .................................... 1201-1256 12 Sensors & Monitors ................... 233-234 13 High Performance Relays and Contactors (overview) ....... 233-234 14 STA ....................... Discrete Function Time Delay Relay ... 1236 VTM-1 ................... Discrete Function Timing Module ....... 1240 VTM1 .................... Discrete Function Timing Module ....... 1241 VTM2 .................... Discrete Function Timing Module ....... 1244 VTM3 .................... Discrete Function Timing Module ....... 1245 VTM4 .................... Discrete Function Timing Module ....... 1246 VTM7 .................... Discrete Function Timing Module ....... 1247 VTMA1 ................. Discrete Function Timing Module ....... 1242 VTMR1 ................. Discrete Function Timing Module ....... 1243 Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1201 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B P&B Solid State Time Delay Terms and Definitions A wide selection of various types of solid state time delay controls are presented by Potter & Brumfield to meet the demands of commerce and industry. Typical applications for P&B time delay relays include data processing operations, machine tool, safety device control and alarm circuit actuating. These diverse applications require a wide variety of time delays such as: fixed time delay on “operate” or “release” which is factory set and cannot be adjusted; resistor-adjustable time delay on “operate“ which is adjustable with an external resistor; knob-adjustable time delay on “operate” which has a calibrated knob built into the assembly for ease of adjusting the time period. Each of the series of solid state time delays presented here varies in its degree of accuracy, variety available and cost to meet the requirements of every application. Timing Variations - Any difference between the actual time delay of a particular device and the nominal value specified for that device. These variations are due to: (1) Manufacturing tolerances (component selections and tolerances, adjustments, etc.). (2) Input voltage variation. Includes DC or rms voltage variations, plus instantaneous voltage variations at time the control voltage is applied (AC only). (3) Temperature (ambient plus self heating). (4) Input cycling conditions: a. duration of “off” time b. duration of “on” time after actual time out The terms used to define and specify time delay relay performance must reflect one or more of these time variation factors with sufficient clarity that both the manufacturer and the user may arrive at essentially the same evaluation of device performance. To this end, the following terms and definitions are used. Specified Delay Time - The advertised (or print specified) time of the delay function. Actual Time, Standard Conditions (ATSC) - The actual delay time of a given device operated at 25°C and nominal input voltage, with sufficient “off” time of input voltage to permit full “short term” recovery of the timing interval. For purposes of establishing a reference ATSC it is recommended that the device be cycled @ 25°C, nominal voltage, with input pulses of 1.3X specified delay time, with 1 sec. off times. The resulting average of a group of consecutive time delay readings (excluding the 1st, which had an unknown off time) may be used to determine ATSC. Five cycles should be considered adequate for this determination. The off time required for full “short term” recovery of the timing interval will vary to some extent, depending on relay type, timing circuit impedance (normally related to length of timing period), whether capacitor shorting contacts are used, whether the previous timing cycle was completed or interrupted during time out, and, if completed, the degree to which the input control “on” time extended beyond actual time out. In practice, off times used may vary from a minimum approaching the release time of the output (50 to 200 ms typical, depending on the particular design) to a second or more, with as much as 15% difference in the resulting delay times. The greatest rate of change occurs as off times become increasingly short, while the rate of change becomes relatively negligible as increasingly long off times approach 1 second. However, for very long off times (measured in hours), and additional change in the first subsequent operation delay time may be experienced. Dimensions are shown for 1202 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. This additional change may be as much as 1-4% (depending again on time delay type and design) and is usually obtained with off periods from 1-24 hours or more. Repeatability - The percent variance of time within a group of consecutive timing cycles, starting with the second operation, when the timing device is operated under constant conditions (constant on-off times, input voltage and temperature). The average of a series of five consecutive operations, at any given set of conditions within specifications, will serve as the reference for determining the variation of individual readings within the group from the average. The maximum variation under such conditions should not exceed the repeatability value specified. For convenience, repeatability under standard conditions could be determined from the test used to measure ATSC (see below, left). Tolerance - The variation between the specified delay time and the ATSC value, given in percent of the former. Delta-Time - The percent timing change (from the ATSC value) for any variation of voltage and/or temperature within specified limits. Tests for this parameter would be essentially the same as described for ATSC, except that any constant combination of specified voltage and temperature extremes may be used. Recycle Time - The length of time the control voltage must be interrupted, immediately following a timing interval, to produce a subsequent delay of at least 95% of the reference delay under constant conditions of input voltage and ambient temperature. The reference delay may be the ATSC value determined under standard conditions (nominal voltage and 25°C); however, any constant voltage-temperature combination within specifications may be used (must be the same voltage-temperature combination as used for recycle checks). Note: If control voltage is interrupted prior to completion of a timing period, or at a time other than immediately following time out, the recycle time value (off time) may produce a subsequently shorter timing period, depending upon the particular design and when the interruption occurs within the internal RC charging cycle. Correspondingly, this subsequent time delay may be from 85% to 95% of the reference actual delay as defined above. Timing Cycle Interrupt “Transfer” - A momentary transfer (pickup and dropout) of the switching relay contacts which may occur if the timing cycle is interrupted. This phenomenon is inherent in CU series time delays; and, depending on when the timing interval is interrupted, the transfer duration may vary from zero to the release time value for that device. Release Time - The time required, after time out, for the output switch to return to its normal, de-energized state when the control voltage is removed. This will vary to some extent with the duration of “on” time after actual time out and with temperature and voltage; the shortest release time being obtained when control voltage is removed immediately following completion of a timing period under conditions of minimum temperature and input voltage. Transient Protection is provided so that the time delay will not be damaged by a transient input. Polarity Protection is provided internally to protect the time delay of DC units from reversal of input voltage. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B External Resistor Selection Guide for P&B Time Delay Relays For CL, CK & CU Series For CD Series The "minimum" time setting on an external resistor adjustable model in any of these series is obtained by shorting together the external resistor terminals of the relay. The “maximum” time setting (within tolerance limits) is obtained by using the resistance value listed across from the maximum time for that unit in the tables below. Timing values between the minimum and maximum limits are linear with resistance within 10%. It is recommended that a 1/4 watt, mimimum, resistor be used. External timing resistor should have less than 500 PPM temperature coefficient. The "minimum" time setting on an external resistor adjustable model in the CD series is obtained by shorting together the external resistor terminals of the relay. The “maximum” time setting (within tolerance limits) is pre-set at the factory, and no external resistor is necessary. Approximate resistance values required to obtain times between the minimum and maximum limits can be determined using the table and graph below. It is recommended that a 1/4 watt, mimimum, resistor be used. External timing resistor should have less than 500 PPM temperature coefficient. The external resistor value R0 required to obtain any time T0 can be calculated using the following formula: R0 = R1 T0 TS T1 R1 R0 = = = = = ( T0 – TS T1 – TS CD Resistor Values (AC & DC Models) ) Factory-set Time Delay. No Resistor (seconds) Desired Time Short Time (see relay type) Long Time (see relay type) Extrernal Resistor Value required to obtain T1 External Resistor Value required to obtain T0 Example: Given a CUH-41-30060, find an external resistor value that will give a 30 second delay. Known: T1 TS R1 R0 = = = = 60 seconds 1 second 1 meg 1 x 106 (29) 59 Approximate Resistance* to Reduce Delay by 1/2 Short Circuit Time Delay (seconds) 1.0 33K ohms 0.1 5.0 200K ohms 0.1 10.0 400K ohms 0.1 * Resistor values shown correspond to a 1.0 multiplying factor. Use the graph below to determine other resistor values required to obtain time periods between the limits stated in the chart. CD Timing Resistor Curve R0 = 492K CL & CU Delay On Operate Resistor Values Time (Sec.) Approximate Resistance CU CL AC DC 1.0 10.0 0.1 10.0 Short 200K Short 160K 1.0 30.0 0.3 30.0 Short 600K Short 500K 1.0 60.0 0.6 60.0 Short 1.2 Meg Short 1.0 Meg 1.0 120.0 1.2 120.0 Short 2.4 Meg Short 2.0 Meg Percent of Maximum Time 100 Note: The actual time obtained will normally be within 5% of the desired time. This is due to construction tolerance. 90 80 70 60 50 40 30 20 10 0 0.01 0.1 1.0 10.0 100 Resistor Multiplying Factor To obtain CD series time delay relays having a linear resistance with time, please consult the factory. CK Delay On Operate Resistor Values Time Approximate Resistance (Sec.) AC DC 0.1 10.0 Short 750K Short 750K 1.8 180.0 Short 1.0 Meg Short 910K CK Delay On Release Resistor Values Time Approximate Resistance (Sec.) AC & DC 0.1 10.0 Short 820K 0.6 60.0 Short 910K Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1203 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT AGASTAT Solid State Time Delay Terms and Definitions Accuracy, absolute (or calibration accuracy) - the deviation of a selected time delay from the actual delay, measured with reference to a time standard, under standard conditions. Load rating - the maximum current, voltage, and frequency (if AC) of the loadcircuit energy that may be switched by a TDR, for normal life expectancy. Accuracy, "attainable" - the "worst case" deviation in time delay, from a selected value, including all factors that contribute to its "error budget," including long-term drift, temperature drift, resolution, calibration accuracy, line-voltage and line-frequency effects, etc. Mode - see operating mode. Accuracy, overall - the maximum deviation from the average of 100 consecutive time delays at any given time setting throughout the operating temperature, voltage, and frequency ranges. Accuracy, repeat - the maximum deviation from the average of 100 consecutive time delays at any given time setting and any fixed combination of temperature and operating voltage. Breakdown, circuit-to-case - the voltage insulation between any part of a TDR's circuitry and the frame or any other conductive part in the structure, including the case. breakdown, control-to-load - the voltage insulation between control and load circuits. Calibration linearity - in the mechanical calibration of a TDR delay-setting scale, the largest deviation of the actual delay-vs-rotation curve from a straight line drawn from minimum to maximum delay. Counting TDR - a TDR in which a stable source generates precisely timed voltage pulses, and a digital counter registers a different voltage pattern or code on its output terminals for each pulse counted. The counter is connected to a digital decoder, preset to recognize a given code, which then operates the load-switching device. Current drain - the current drawn by the delay and switching circuits in the TDR, not including the current drawn by the load. delay - an interval of time generated before some planned event is caused to occur. Delay adjustability - the capability of setting the duration of a time delay generated by a TDR; the Delay range and resolution - taken together, describe the adjustability. Delay adjustment - means of setting the duration of a time delay: pointerknob-and scale, thumbwheel switch, external or internal potentiometer, etc. delay range - the span of time within which a TDR can generate time delays. Dielectric withstand - the ability of insulating materials and spacings to withstand specified overvoltages for a specified time without flashover or puncture. Electromechanical relay (EMR) - a controlled switch operated by causing sufficient current to flow through an electromagnetic coil; the resultant magnetic field, when strong enough, overcomes a spring force and closes and/ or opens the switch contacts. Interface - in a TDR, one of the following: the nature of the means of adjusting time delay; of indicating status of delay and load; of powering control and load circuits, or of switching control and load circuits. Isolation, control-to-load - the degree to which interaction has been prevented between control and load circuits in a TDR usually expressed as the effective impedance between them. Load gates - solid state circuits that perform logic "switching functions." Noise - any unwanted signal impinging on a circuit or its environment. Operate time - the longest interval between energization of an output relay and the completion of contact transfer under any combination of operating temperature and voltage. Operating life - a measure of the number of operations a TDR can be expected to perform within specifications; for TDRs with electromechanical (EMR) loadswitching means, there are two ratings - mechanical and electrical operations at full rated load. Operating mode - the relationship between control signal input, generation of delay or count, and transfer of load-switching contacts. operating voltage range - the range of voltages over which a TDR will perform to specification. May be applied to either delay generating circuits, loadswitching circuits or both. Peak current - the maximum short-duration load-circuit rating of the loadswitching circuit; also called "in-rush" or "surge" current. R-C timer - an electronic time-delay relay in which the charging of a capacitor (C) through a resistor (R) generated the delay and an electronic circuit establishes a threshold, or critical value, for the capacitor voltage; when this value is reached, a load-switching device is operated. Release time - the longest time interval between de-energization of an output relay and the complete transfer of its contacts under any combination of operating temperature and voltage. Resettability - the precision with which a delay adjustment, once changed, can be reset. Reset time - the shortest allowable interval between complete or interrupted timing cycles without risk of delay error or malfunction. Resolution - the precision with which delay adjustment may be set; it depends on the type of adjustment means; for example, in a switch-settable design, the smallest change that can be made by moving one unit in the least-significant decade in a selector switch array. solid-state relay (SSR) - a relay in which a semiconductor device (e.g., an SCR or TRIAC), switches the load. Stability, long-term - the measure of the effect of time along on the delay generated by a TDR under specific operating conditions - e.g., the difference in the repeat accuracy between that measured when the TDR is new, and that measured one year later. Stability, temperature - the effect of ambient temperature on the delay of a TDR, expressed in terms of the percent deviation in a preset delay per degree of temperature change from some nominal value. TDR - time-delay relay. Time-delay relay (TDR) - a device that upon energization or operation of a control circuit, generates a delay, at the end of which some planned event (e.g., load switching, or secondary control function) is caused to occur. Leakage current - the current conducted by a solid state switching device in an "off" state. Timing diagram or timing ladder - a graphic representation of two or more sequences of events, all drawn to the same horizontal time scale, so that any point in one sequence occurs at the same time as any point directly above or below it in another sequence. LED readout - a numerical display made up of light-emitting diodes (solid state devices that glow when current is passed through them). Timing range - the range of time intervals over which a particular TDR will generate delays. linearity - the regularity of calibration of a delay scale - i.e., the uniformity of the spacing equal delay increments. In a TDR with externally controlled delay, the constancy of the delay-to-resistance ration. Transfer - the switching of a relay's contacts from one state to the other, but in the past tense commonly used to denote the position of the contacts in the relay's energized or "transferred" state as opposed to its de-energized or "normal" state. Line-frequency sensitivity - the deviation in delay, at any setting within specifications, per hertz or percent of line-frequency change from the nominal value, measured at specified line voltage and ambient temperature. Line-voltage sensitivity - the deviation in delay, at any setting within specification, per volt or percent of line-voltage change from the nominal value, measured at specified line voltage and ambient temperature. Load-dependent delay - the characteristic of certain TDR's in which there is a significant change, due to internal heating, of a preset delay interval, following a long "load-ON" period. Dimensions are shown for 1204 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Transient protection or transient suppression - the prevention of malfunction of a TDR due to power-line transients, or the means of doing so. Usually effective only over a stated range or up to a stated maximum transient amplitude and duration. Transient voltage tolerance - the largest momentary overvoltage peak that a TDR will withstand without damage or catastrophic malfunction. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT AGASTAT Time Delay Relay Timing Modes On-Delay: Time delay is initiated upon application of a control signal (i.e., operating voltage or on 11-pin model closure of the control switch). The output contacts energize at the end of the delay. Output contacts and the time delay circuit reset upon removal of the control signal regardless of state. ON / CLOSED OPERATING VOLTAGE/ CONTROL SWITCH OFF / OPEN On-Delay / Off-Delay: Time delay is initiated for delay 1 upon closure of the control switch, for delay 2 upon opening of the control switch. (Operating voltage is applied continuously.) Output contacts energize at the end of time delay 1, and de-energize at the end of time delay 2. If the control state is reversed during the time delay, the time delay circuit automatically resets to zero. Note: For the 48K series, time delays 1 and 2 are identical. ON OPERATING VOLTAGE ENERGIZED OUTPUT CONTACTS OFF DELAY CLOSED DE-ENER. CONTROL SWITCH OPEN Off-Delay: The output contacts energize when the control switch is closed. The time delay is initiated upon opening of the control switch (operating voltage is applied continuously). De-energization occurs at the end of the delay. Output contacts energize and the time delay circuit resets upon closure of the control switch. ENERGIZED OUTPUT CONTACTS DE-ENER. DELAY 1 DELAY 2 Repeat Cycle: Application of the operating voltage starts time delay 1. Upon expiration of this delay, the output contacts energize. Time delay 2 begins simultaneously. At the end of time delay 2, the output contacts de-energize, and a new cycle begins. The cycles continue until power is removed. To reset the timer, input voltage must be removed. The state of the output contacts may be reversed on the 11-pin 48K by closing the control switch. Note: For the 48K series, the time delays are identical. ON OPERATING VOLTAGE OFF CLOSED CONTROL SWITCH OPEN ENERGIZED OUTPUT CONTACTS DE-ENER. DELAY ON OPERATING VOLTAGE OFF Interval: Time delay is initiated upon application of a control signal (i.e., operating voltage or closure of the control switch on 11-pin models). The output contacts energize when the control signal is applied. At the end of the delay, the output contacts de-energize. Output contacts and the time delay circuit reset upon removal of the control signal regardless of state. ON / CLOSED OPERATING VOLTAGE/ CONTROL SWITCH OFF / OPEN ENERGIZED OUTPUT CONTACTS ENERGIZED OUTPUT CONTACTS DE-ENER. DELAY 1 DELAY 1 DELAY 2 DELAY 2 Accumulating On-Delay: Time delay is initiated upon closure of the control switch. (Operating voltage is applied continuously.) Energization of the output contacts occurs at the end of the delay. If the control switch is opened during the time delay, the time delay pauses, and the relay holds (remembers) the delay accumulated so far. The time delay resumes when the control switch is re-closed. After energization, reset by opening the control switch. Regardless of state, reset by removing the operating voltage. ON DELAY OPERATING VOLTAGE DE-ENER. OFF CLOSED On / Interval : Time delay 1 is initiated upon application of a control signal (i.e., operating voltage or closure of the control switch on 11-pin models). The output contacts energize at the end of time delay 1 and de-energize at the end of time delay 2. Output contacts and the time delay circuit reset upon removal of the control signal regardless of state. Note: For the 48K series, delay 2 is fixed at 0.5 seconds. CONTROL SWITCH OPEN ENERGIZED OUTPUT CONTACTS DE-ENER. DELAY ACCUMULATION ON / CLOSED OPERATING VOLTAGE/ CONTROL SWITCH OFF / OPEN ENERGIZED OUTPUT CONTACTS DE-ENER. DELAY 1 DELAY 2 One Shot (Latching Interval): Operating voltage must be applied continuously. Output contacts energize and time delay is initiated upon closure of the control switch. Once closed, state of control switch has no further influence until time delay has expired. Upon expiration of time delay, output contacts deenergize and timer is reset by opening the control switch. ON OPERATING VOLTAGE OFF CLOSED CONTROL SWITCH Note: When an external control switch is used, it must be closed before the unit is energized. If external control switch is open, the unit will not time out. OFF AT ANY TIME OPEN ENERGIZED OUTPUT CONTACTS DELAY DE-ENER. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1205 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Accessories for AGASTAT Solid State Time Delay Relays Sockets BDS08SS Socket • 8-pin octal socket • DIN rail or panel mount • Rated 10A @ 300VAC • #6-32 screws w/captive clamp plates • File E140494 • File LR29523M37 BDS11SS Socket • 11-pin octal-type socket • DIN rail or panel mount • Rated 10A @ 300VAC • #6-32 screws w/captive clamp plates • File E140494 • File LR29523M37 BCSF11SC Socket • Use with SCF series timer • 11-pin octal-type socket • DIN rail or panel mount • Rated 10A @ 380VAC • M3 screws w/captive clamp plates • File E140494 • File LR29523M37 BDT11SS Socket • 11-pin tab socket • DIN rail or panel mount • Rated 10A @ 300VAC • #6-32 screws w/captive clamp plates • File E140494 • File LR29523M37 External Potentiometer POT1MV External Potentiometer Time adjustment by extermal potentiometer or fixed resistor for series SCB, SCC,SSC, STA, VTM-1, VTM1, VTM2, VTM3, VTM4 & VTM7. (Potentiomter or resistor furnished by customer.) Minimum time is obtained with zero resistance. Longer time is obtained by adding resistance specified at right for each second, hour or cycle above the minimum. Alternatively, an external 1 megohm potiometer may be used. Dimensions are shown for 1206 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. Time Range .1 to 3 sec. .1 to 10 sec. .5 to 15 sec. 1 to 30 sec. 2 to 60 sec. 4 to 120 sec. 6 to 180 sec. 10 to 300 sec. Ohms (±10%) 333.3K/sec. 100.0K/sec. 66.7K/sec. 33.3K/sec. 16.7K/sec. 8.3K/sec. 5.6K/sec. 3.3K/sec. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B 3RP1 series Multifunction Solid State DIN Mount Time Delay Relay • • • • • • • Available as SPDT or DPDT 15 time setting ranges .05s - 100hr programmable timing range Universal 24-240 VAC/VDC or fixed input types. 3A switching current rating Fits 35mm DIN track Single function, Delay-On available VDE Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Standards and Specifications Contact Data @ 25°C • IEC 721-3-3 "Ambient conditions" • IEC 61812-1/DIN VDE 0435 Part 2021 "Solid State Relays, Time Relays" • IEC 1000 "electromagnetic compatibility" • IEC 947-5-1: DIN VDE 0660 Part 200 "Low-voltage control circuit devices" Arrangements: 1 Form C (SPDT). 2 Form C (DPDT) Material: Silver tin oxide. Rating: 3A @ 250VAC. Switching Frequency: 2,500 ops./hour. Electrical Life: 200,000 operations min. at rated load. Mechanical Life: 30 x 106 operations. Input Data @ 25°C Timing Specifications Voltage: Universal Input Type: 24 - 240V, 50/60 Hz. AC or DC. Fixed Input Type: 24, 100-127, 200-240AC; 24VDC. Operating Range: AC: 85 to 110%. DC: 80 to 125%. Power Requirement: Universal Input Type: AC: 6VA. DC: 2W. Timing Ranges: 0.05 to 1 / 0.15 to 3 / 0.5 to 10 / 1.5 to 30 / 5 to 100 sec.; 0.05 to 1 / 0.15 to 3 / 0.5 to 10 / 1.5 to 30 / 5 to 100 min.; 0.05 to 1 / 0.15 to 3 / 0.5 to 10 / 1.5 to 30 / 5 to 100 hr. Timing Adjustment: Potentiometer adjustable within selected range. Tolerance: ± 5% of full scale value. Reset Time: 150 ms. Minimum On Period: 35 msec. Repeatability: ± 1%. Environmental Data Temperature Range: Storage: -40°C to +80°C. Operating: -25°C to +60°C. Protection Category: IP 20 according to EN 60529. Timing Modes Mechanical Data See the following page for a description of timing modes. Termination: Screw terminal. Enclosure: Plastic DIN case. Mounting: 35mm DIN track. Weight: (3RP1505) 5.29 oz. (150g) approximately. (3RP1525) 3.88 oz. (110g) approximately. Configuring • Changing the timer range and their functions will only be effective when they are carried out in a voltage-free state. • Trigger input B1 or B3 must only be started when the supply voltage is applied. • The same potential must be applied to A1 and B1, or A3 and B3. With the two-voltage design, only one voltage range must be connected. • The triggering of the load paralleled to the start input is not permissible when using AC (see adjacent diagrams). L1 L1 S1 S1 A1 K2 A2 N B1 K1 A1 K2 S1 B1 K1 N Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Input Voltage DC AC 3RP1505 Multifunction 24 24 24 24-240 24, 100-127 24, 200-240 24, 100-127 24-240 Input Type Contact Arrang. Wiring Diagram Functions Part Number Fixed Fixed Fixed Universal SPDT SPDT DPDT DPDT 1 to 8 1 to 8 9 to 24 9 to 24 1 to 8 1 to 8 9 to 24 9 to 24 3RP15 05-1AQ30 3RP15 05-1AP30 3RP15 05-1BQ30 3RP15 05-1BW30 Fixed Fixed Fixed Fixed SPDT SPDT DPDT DPDT 1 1 9 9 1 1 9 9 3RP15 25-1AQ30 3RP15 25-1AP30 3RP15 25-1BQ30 3RP15 25-1BP30 3RP1525 Delay On 24 24 24 24 24, 100-127 24, 200-240 24, 100-127 24, 200-240 Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1207 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Outline Dimensions 3RP1505-1A, 3RP1525-1A 3RP1505-1B, 3RP1525-1B 3.39 (86.0) .19 (5.0) .31 (8.0) 2.36 (60.0) 2.99 (76.0) 2.36 (60.0) 1.18 (30.0) .31 (8.0) 4.33 (110.0) 3.54 (90.0) 3.23 (82.0) 3.39 (86.0) .19 (5.0) 3.23 (82.0) 4.33 (110.0) 2.44 (62.0) 4.02 (102.0) 2.44 (62.0) 4.72 (120.0) 4.72 (120.0) .59 (15.0) .59 (15.0) .23 (6.0) .886 (22.5) .23 (6.0) .886 (22.5) Wiring Diagram 1. On-Delay 2. Off-Delay With Auxiliary Voltage 3RP1505-1A 3RP1525-1A 3RP1505-1A 3RP1505-1A AC/DC 24V AC/DC 24V A1 A3 15 A2 16 18 A1 B1 A3 B3 15 5. Making-Pulse Contact 3RP1505-1A 3RP1525-1A A2 16 18 6. Breaking-Pulse Contact With Auxiliary Voltage AC/DC 24V A1 A3 15 A2 ➝ 16 18 15 25 A2 16 18 26 28 13. Making-Pulse Contact 3RP1505-1B A1 B1 A3 B3 15 A2 ➝ 16 18 Dimensions are shown for 1208 reference purposes only. 11. On-and Off-Delay With Auxiliary Voltage 25 ➝ 26 28 AC/DC 24V 16 18 25 A2 16 18 A1 B1 A3 B3 15 26 28 15. Pulse Forming With Auxiliary Voltage A2 26 28 Dimensions are in inches over (millimeters) unless otherwise specified. 26 28 16. Additive On-Delay With Auxiliary Voltage and Instantaneous Contact AC/DC 24V AC/DC 24V 25 16 18 25 3RP1505-1B AC100/127V AC200/240V AC100/127V AC200/240V A1 B1 A3 B3 15 12. Flashing AC100/127V AC200/240V A2 AC/DC 24V 16 18 3RP1505-1B A1 B1 A3 B3 15 26 28 AC100/127V AC200/240V 15 A2 3RP1505-1B ➝ A2 16 18 25 ➝ A1 A3 ➝ 16 18 AC/DC 24V 14. Breaking-Pulse Contact With Auxiliary Voltage AC/DC 24V A1 B1 A3 B3 15 AC100/127V AC200/240V 3RP1505-1B AC100/127V AC200/240V AC/DC 24V 3RP1505-1B AC100/127V AC200/240V A1 A3 8. Additive On-Delay With Auxiliary Voltage and Instantaneous Contact AC100/127V AC200/240V A2 AC/DC 24V AC/DC 24V 16 18 Σ ➝ 16 18 3RP1505-1B AC100/127V AC200/240V A2 3RP1505-1A A1 B1A3 B3 15 10. Off-Delay With Auxiliary Voltage 3RP1505-1B 3RP1525-1B 15 AC/DC 24V A1 B1A3 B3 15 9. On-Delay 7. Pulse Forming With Auxiliary Voltage AC100/127V AC200/240V A2 A1 A3 16 18 3RP1505-1A AC100/127V AC200/240V AC100/127V AC200/240V AC/DC 24V AC100/127V AC200/240V A1 B1 A3 B3 15 3RP1505-1A AC/DC 24V 3RP1505-1A AC100/127V AC200/240V A2 4. Flashing AC/DC 24V AC100/127V AC200/240V AC100/127V AC200/240V 3. On and Off Delay With Auxiliary Voltage A1 B1 A3 B3 15 25 A1 B1 A3 B3 15 21 Σ A2 ➝ 16 18 ➝ 26 28 Specifications and availability subject to change. A2 16 18 22 24 www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Wiring Diagrams (continued) 18. Off-Delay With Auxiliary Voltage and Instantaneous Contact 3RP1505-1B 19. On and Off Delay With Auxiliary Voltage and Instantaneous Contact 3RP1505-1B AC/DC 24V 3RP1505-1B 15 21 A2 16 18 22 24 A2 21. Making-Pulse Contact and Instantaneous Contact AC100/127V AC200/240V A1 B1 A3 B3 15 21 A2 22 24 16 18 22. Breaking-Pulse Contact With Auxiliary Voltage and Instantaneous Contact 3RP1505-1B A2 ➝ 16 18 22 24 A2 ➝ 21 21 22 24 A2 16 18 22 24 24. Star-Delta Function 3RP1505-1B AC/DC 24V AC/DC 24V A1 B1 A3 B3 15 15 15 AC100/127V AC200/240V AC100/127V AC200/240V AC100/127V AC200/240V A1 A3 A1 A3 3RP1505-1B AC/DC 24V AC/DC 24V 16 18 21 23. Pulse Forming With Auxiliary Voltage and Instantaneous Contact 3RP1505-1B AC100/127V AC200/240V AC/DC 24V AC100/127V AC200/240V A1 B1 A3 B3 15 A1 A3 3RP1505-1B AC/DC 24V AC/DC 24V AC100/127V AC200/240V AC100/127V AC200/240V 20. Flashing and Instantaneous Contact 16 18 A1 B1 A3 B3 15 21 ➝ 16 18 A2 22 24 21 A1 A3 22 24 A2 17 27 Y18 ∇ 17. On-Delay and Instantaneous Contact 28 Timing Function Descriptions and Settings 3RP1505-1A 3RP1505-1B 1. On Delay 5. Impulse On 9. On Delay 13. Impulse On 17. On Delay A./A2 A./A2 A./A2 A./A2 A./A2 15/18 15/16 15/18 15/16 t 15/18 15/16 t 15/18 15/16 t 25/28 25/26 25/28 25/26 15/18 15/16 t 21. Impulse On A./A2 15/18 15/16 t 21/24 21/22 21/24 21/22 t 2. Off Delay 6. Impulse Off 10. Off Delay 14. Impulse Off 18. Off Delay 22. Impulse Off A./A2 A./A2 A./A2 A./A2 A./A2 A./A2 > _ 35ms B./A2 15/18 15/16 t 3. On/Off Delay > _ 35ms B./A2 15/18 15/16 t > _ 35ms B./A2 15/18 15/16 t 25/28 25/26 > _ 35ms B./A2 15/18 15/16 t 25/28 25/26 > _ 35ms B./A2 15/18 15/16 t 21/24 21/22 11. On/Off Delay 15. Pulse Shaping 19. On/Off Delay A./A2 A./A2 A./A2 A./A2 A./A2 A./A2 B./A2 15/18 15/16 B./A2 15/18 15/16 B./A2 15/18 15/16 B./A2 15/18 15/16 B./A2 15/18 15/16 B./A2 15/18 15/16 t t t 25/28 25/26 t t 25/28 25/26 > _ 35ms t t 8. Cumulative On Delay 12. Flasher 16. Cumulative On Delay 20. Flasher A./A2 15/18 15/16 A./A2 t1 B./A2 15/18 15/16 A./A2 15/18 15/16 A./A2 t1 B./A2 15/18 15/16 t t Dimensions are shown for reference purposes only. t3 Σt t2 25/28 25/26 t t 22/24 21/22 Dimensions are in inches over (millimeters) unless otherwise specified. t 21/24 21/22 4. Flasher t3 Σt t2 A./A2 15/18 15/16 21/24 21/22 Specifications and availability subject to change. t t 21/24 21/22 7. Pulse Shaping > _ 35ms > _ 35ms B./A2 15/18 15/16 23. Pulse Shaping > _ 35ms t 21/24 21/22 24. Star/Delta t A./A2 17/18 27/28 t 50ms www.tycoelectronics.com Technical support: 1209 Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) NOTE: This product has been discontinued. This data is for reference only. Suggested alternatives are the P&B CNT, CNS and CNM5 series time delay relays. AGASTAT 48K series Programmable Time Delay Relay • • • • • • • Up to 8 user-programmable timing modes 0.1 sec. to 10 hr. programmable timing range Socket or panel mount (1/16 DIN enclosure) Universal (24-240VAC/24-125VDC) and fixed input types 10A output relay with DPDT contacts Two LED indicators on universal input types ANSI C37.90 transient protection on universal input types File E60363 File LR29186 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Initial Dielectric Strength Modes are user selectable via rotary selector switch (shown above) or screwdriver adjustment on optional recessed knob equipped models that are available on a special order basis for tamper-resistant requirements. Modes offered on specific models are: 48K91U: On-Delay, Off-Delay, Interval, On/Interval, One Shot, Repeat Cycle, On-Delay/Off-Delay, Accumulating On. 48K90U: On-Delay, Interval, On/Interval, Repeat Cycle. 48K01A: On-Delay. Between Coil, Contacts and Case: 1,500VAC. Timing Specifications Timing Ranges: 0.1 to 1 / 1 to 10 / 10 to 100 sec.; 1 to 10 / 10 to 100 min.; 1 to 10 hr. Timing Adjustment: Potentiometer adjustment with linear reference calibrations. Recessed dial option is available on a special order basis for tamper-resistant requirements. Accuracy: Repeat Accuracy: ± 0.5% ± 0.02 sec. Overall Accuracy: ± 1% ± 0.02 sec. Reset Time: 25 ms. Relay Operate Time: 50 ms. Relay Release Time: 50 ms. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 30VDC or 120/240VAC, resistive. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Input Data @ 25°C Voltage: 48K90U & 48K91U: 24 - 240VAC, 50/60 Hz. and 24-125VDC. 48K01A: 120VAC, 50/60 Hz. Power Requirement: 2W, max. Transient Protection: 48K90U & 48K91U: Meets ANSI C37.90 Transient Specification. 48K01A: 2,500V for 1ms. Environmental Data Temperature Range: Storage: -25°C to +85°C. Operating: -25°C to +60°C. Mechanical Data Termination: 8 or 11-pin octal style plug. Enclosure: Grey plastic 1/16 DIN case for socket or panel mounting. Indicating LEDs: 48K90U & 48K91U: Power On LED & Output Contacts LED (Typically flashes when timing, stays on when output relay is energized.) 48K01A: Output Contacts LED Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 5 oz. (142g) approximately. Ordering Information – Authorized distributors are likely to stock boldface part numbers listed below. Part Number Timing Modes Operating Voltage Termination Pins 48K01AS One - On-Delay 120VAC 50/60 Hz. 8 48K90US Four - On-Delay, Interval, On/Interval, Repeat Cycle Universal (24-240VAC, 50/60 Hz. or 24-125VDC) 8 48K91US Eight - On-Delay, Off-Delay, Interval, On/Interval, One Shot, Repeat Cycle, On-Delay/Off-Delay, Accumulating On Universal (24-240VAC, 50/60 Hz. or 24-125VDC) 11 Ordering Note: The part numbers listed above are standard products with knobs for adjustment of mode, range and timing. On a special order basis other models are available with recessed dials requiring a screwdriver for adjustment. On the special order versions, the "S" part number suffix is replaced by an "R" suffix. Consult factory for availability of special order models. Outline Dimensions Wiring Diagrams (Bottom Views) (pins numbered clockwise from keyway) 1.89 (48.0) Max. 48K91US (dotted line represents internal connection) 1.89 (48.0) Max. Dimensions are shown for 1210 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. 48K90US 48K01AS www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CNT series Multifunction, Digital Time Delay Relay/Counter • • • • • • • 10 programmable timing modes + 2 counting modes 0.1 sec. to 9,990 hr. programmable timing range 1 to 99,900 counting range LCD digital display Universal (24-240VAC/VDC) and fixed input types 10A output relay with DPDT contacts Thumbwheel switches for programming File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing and Counting Modes Input Data @ 25°C See the following page for a complete description of all programmable timing and counting modes. Voltage: Universal Input Type: 24 - 240V ± 15%, 50/60 Hz. AC or DC. Fixed Input Types: 120VAC ± 15%, 50/60 Hz and 12VDC. Power Requirement: Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC. 10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC. Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC. Transient Protection: Yes. Reverse Voltage Protection: Yes. Timing Specifications Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.; 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. Timing Adjustment: Digital adjustment via thumbwheel switches. Tolerance: ±0.5% ±0.05 sec. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 0.1% ± 0.05 sec. Repeatability (Including first cycle of operation.): ±0.1% ±0.05 sec. Reset Time (power interruption): 45 ms, typ.; 60 ms, max. Minimum Pulse Width, Control: 50 ms. Recycle Time: 45 ms, typ.; 60 ms, max. Counting Specifications Maximum Count: 1 to 999; 10 to 9,990 (÷10); 100 to 99,900 (÷100). Maximum Count Rate: 100 counts per second. Mimumum Pulse Width:Count (Control): 3 ms.; Reset: 3 ms. Available Counting Functions: Operate at preset count and release at preset count. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Initial Dielectric Strength Between Open Contacts: 1,000V rms, 60 Hz. Between All Other Conductors: 1,500V rms, 60Hz. Input Voltages & Limits @ 25°C Input Type Nominal Voltage Minimum Voltage Maximum Voltage Universal Fixed 24-240VAC/VDC 120VAC 12VDC 20.4VAC/VDC 102VAC 10.2VDC 276VAC/VDC 138VAC 13.8VDC Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. Environmental Data Temperature Range: Storage: -20°C to +70°C. Operating: -10°C to +55°C. Humidity: 85% relative humidity, non-condensing. Mechanical Data Termination: 11-pin octal style plug. Enclosure: Beige plastic 1/16 DIN case. Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 4.3 oz. (122g) approximately. External Control: CONTROL, RESET: Active on contact closure or solid state switch closure to RETURN, 0-1.0VDC maximum voltage level (see wiring diagrams for interface circuits. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Accessories Universal Input Model Input Voltage 24-240VAC/VDC Part Number Part Number CNT-35-96 SSA-24C667 Part Number 12VDC 120VAC CNT-35-26 CNT-35-76 Outline Dimensions 1.88 (47.8) Wiring Diagrams (Bottom Views) .32 (8.1) (pins numbered clockwise from keyway) 2.83 (71.9) EXTERNAL CONTROL SWITCHES** CONTROL (COUNT) RETURN O NC 1 1 H + Fits 1.77 x 1.77 (45 x 45) Panel cutout Dimensions are shown for reference purposes only. 3.15 (80.0) .64 (16.3) Dimensions are in inches over (millimeters) unless otherwise specified. RETURN USE SAME FOR RESET 1.76 (44.7) 1 RESET CONTROL RESET N 1.88 (47.8) A Description Ratchet-fit clip slides onto CNT from behind to secure CNT in panel mount applications. SSA-24C668 Protective Cover Clear, flexible cover slips snugly over bezel of CNT to help protect against dust and moisture. Durable cover also helps prevent inadvertant changes of programming switch settings. Fixed Input Models Input Voltage Name Mounting Clip 1 11 INPUT* _ + 1 11 INPUT* _ * Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. ** Important: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1211 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Protective Cover & Mounting Clip Dimensions SSA-24C668 SSA-24C667 Protective Cover “A ” Mounting Clip 1.99 (50.5) .40 (10.2) 2.283 1.970 (58.0) (50.0) 2.047 (52.0) 1.99 (50.5) .591 (15.0) 1.654 (42.0) 1.890 (48.0) Section "A-A" “A ” Programming Switch Diagram With this setting, the relay would operate after a delay period of 214 seconds. Function Select: Timer Mode: Counter Mode: A = Delay On Operate B = Delay On Release C = Interval On D = Control-Off Interval On B = Divide by 10 E = Recycle F = Single Cycle G = Control On-Off Interval On H = Control On-Off Delay C = Divide by 100 A 2 1 4 S I = Pulse J = Cumulative Delay On Operate A & D-J = Normal Count Time/Counter Setting: 001 to 999 Time Base/Counter Mode Select: Time Base: .1S = 0.1 to 99.9 Sec. .1M = 0.1 to 99.9 Min. .1H = 0.1 to 99.9 Hrs. S = 1 to 999 Sec. M = 1 to 999 Min. H = 1 to 999 Hrs. Counter Mode: CO = Operate at Preset Count CR = Release at Preset Count 10H =10 to 9990 Hrs. Timer Function Descriptions A . Delay On Operate Output relay turned on at end of programmed time interval which is started by CONTROL input or power-on with CONTROL on. Relay turned off by RESET input until next cycle is started. With CONTROL on, turning RESET off restarts timing B. Delay On Release Output relay turned on with CONTROL input and remains on for programmed time interval following removal of CONTROL. During time interval after release of CONTROL, RESET turns relay off until cycle restarted with reapplication of CONTROL. With CONTROL on, relay is held off while RESET is activated. C. Interval On Output relay turned on for programmed time interval by CONTROL or poweron with CONTROL on. RESET turns relay off until next cycle is started, and does not restart timing when RESET is removed. D. Control-Off Interval On Output relay turned on for programmed time interval by turn-off of CONTROL. RESET turns relay off until next cycle is started, and does not restart timing when RESET is removed. E. Recycle Output relay turned on at end of programmed time interval which is started by momentary CONTROL input or power-on with CONTROL on. Relay stays on for equal time interval, then turns off and cycle is repeated on a freerunning basis until terminated by momentary RESET, turning relay off. With CONTROL on, turning RESET off restarts cycle. F. Single Cycle Output relay turned on at end of programmed time interval which is started by momentary CONTROL input or power-on with CONTROL on. Relay stays on for equal time interval, then turns off. RESET terminates timing and turns relay off. Turning RESET off does not restart timing. G. Control On-Off Interval On (Watch Dog Timer) Output relay turned on and programmed time interval started or restarted by change of CONTROL input. RESET turns relay off and stops timing. Turning RESET off does not restart timing. H. Control On-Off Delay Output relay turned on at end of programmed timing interval which is started or restarted by change of CONTROL input. If relay is on, turn-off of relay occurs at end of programmed time interval which is started or restarted by change of CONTROL input. RESET turns relay off and stops timing. Turning RESET off does not restart timing. I. Pulse Output relay turned on at end of programmed time interval, which is started by CONTROL input, for 0.5 second duration, and continues in pulsed mode at programmed time interval with fixed 0.5 second on-time. Turning CONTROL off turns relay off and stops timing. RESET turns relay off and inhibits operation. With CONTROL on, removal of RESET restarts timing. J. Cumulative Delay On Operate Output relay turned on at completion of total accumulate CONTROL input duration equal to programmed time. Turning CONTROL off before accumulation of programmed time results in measured time total being held until CONTROL is again turned on and total programmed time value is reached. RESET input resets time value to zero and turns relay off if energized. Turning RESET off restarts timing if CONTROL is on. Counter Function Descriptions CO – Operate at Preset Count – Normal Mode CR – Release at Preset Count – Normal Mode After initializing by momentary activation of RESET input, each on/off signal at COUNT (CONTROL) input increments displayed count in upcounting manner from initial 000 value until preset count, set by thumbwheel switches, is reached and output relay turns on. Additional inputs continue to increment displayed count. Continued counting past maximum count (999) results in a “wrap-around” effect to 000, followed by contrinued up-counting. Activation of RESET input turns relay off and resets count to zero. Initializing by momentary activation of RESET input turns relay on. Operation is similar to CO (Operate at Preset Count) except relay turns off at a preset count. CO or CR – Divide-by-10 Mode Operation is as described previously, except count is incremented for every 10 on/off input signals for a maximum presettable count of 9,990. CO or CR – Divide-by-100 Mode Operation is as described previously, except count is incremented for every 100 on/off input signals for a maximum presettable count of 99,900. Dimensions are shown for 1212 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CNS series Multifunction Time Delay Relay • • • • • • 8 programmable timing modes (4 on 8-pin models) 0.1 sec. to 100 min. programmable timing range Universal (24-240VAC/VDC) and fixed input types 10A output relay with DPDT contacts DIP switch selection of timing mode and range Knob and dial scale for setting actual delay time File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C See the following page for a complete description of timing modes. Voltage: Universal Input Type: 24 - 240V ± 15%, 50/60 Hz. AC or DC. Fixed Input Type: 120VAC ± 15%, 50/60 Hz. Power Requirement: Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC. 10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC. Fixed Input Type: 3VA @ 120VAC. Transient Protection: Yes. Reverse Voltage Protection: Yes. Timing Specifications Timing Ranges: 0.1 to 1.0 / 1.0 to 10 / 10 to 100 sec.; 0.1 to 1.0 / 1.0 to 10 / 10 to 100 min. Timing Adjustment: Knob adjustable within selected range. Tolerance: –0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (Including first cycle of operation.): ± 2% (for AC units add ± 1 cycle 60 Hz.). Reset Time (power interruption): 45 ms, typ.; 60 ms, max. Minimum Pulse Width, Control: 50 ms. Recycle Time: 45 ms, typ.; 60 ms, max. Input Voltages and Limits @ 25°C Input Type Nominal Voltage Minimum Voltage Maximum Voltage Universal Fixed 24-240VAC/VDC 120VAC 20.4VAC/VDC 102VAC 276VAC/VDC 138VAC Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. Contact Data @ 25°C Environmental Data Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10 A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Temperature Range: Storage: -20°C to +70°C. Operating: -10°C to +55°C. Humidity: 85% relative humidity, non-condensing. Initial Dielectric Strength Between Open Contacts: 1,000V rms, 60 Hz. Between All Other Conductors: 1,500V rms, 60 Hz. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: Beige plastic 1/16 DIN case. Dial scale provided for knob adjustment reference. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 4.3 oz. (122g) approximately. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Universal Input Models Input Voltage Accessory Timing Functions No. of Pins Wiring Dia. Part Number 24-240VAC/VDC 24-240VAC/VDC 4 8 8 11 1 2 CNS-35-92 CNS-35-96 Part Number Name Description SSA-24C667 Mounting Clip Ratchet-fit clip slides onto CNS from behind to secure CNS in panel mount applications. Fixed Input Models Input Voltage Timing Functions No. of Pins Wiring Dia. Part Number 120VAC 120VAC 4 8 8 11 1 2 CNS-35-72 CNS-35-76 Outline Dimensions Wiring Diagrams (Bottom Views) (pins numbered clockwise from keyway) 1.88 (47.8) .65 (16.5) .32 (8.1) 2.83 (71.9) \ 1 1.76 (44.7) 1.88 (47.8) + 8 INPUT* 1 – + 11 INPUT* – EXTERNAL CONTROL SWITCH** * Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. Fits 1.77 x 1.77 (45 x 45) Panel Cutout Dimensions are shown for reference purposes only. 3.15 (80.0) Dimensions are in inches over (millimeters) unless otherwise specified. .64 (16.3) ** Important: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. The dotted lines shown between pins on 11-pin diagram indicate internal connections. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1213 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Mounting Clip Dimensions SSA-24C667 Mouting Clip 2.283 1.970 (58.0) (50.0) 2.047 (52.0) 1.654 (42.0) 1.890 (48.0) .591 (15.0) Timing Range Switch Settings DIP Switch Layout DIP Switch Setting On Timing Range DIP Switch Setting 0.1 - 1.0 Second 1 2 3 4 Function Setting 5 6 5 6 7 5 6 7 Time Setting 5 6 7 Note: The solid black blocks in the DIP switch diagrams indicate the switch positions. For example, all the switches are “off” in the diagram above. 0.1 - 1.0 Minute 5 6 7 5 6 7 5 6 7 1.0 - 10 Seconds 7 Timing Range 1.0 - 10 Minutes 10 - 100 Seconds 10 - 100 Minutes Timing Function Descriptions and Switch Settings 8 Or 11 Pin 11 Pin Only Delay on Operate Delay on Release 1 2 3 4 1 72 & 92 - Output relay is energized at the completion of the time interval which is initiated by the application of input voltage. 76 & 96 - Same as the above except, closing the control switch after time out will deenergize the relay and reset the timer. Opening the switch will initiate another time interval. Closing the control switch during timing will reset the time to zero and inhibit timing until opened again. 2 3 4 76 & 96 - Output relay is energized by the closing of the control switch with the input applied or the application of input voltage with the control switch already closed. The time interval will be initiated by the opening of the control switch with the relay de-energizing at the completion of the time interval. Closing the control switch after time out will energize the relay in preparation for another time interval. Closing the control switch during timing will reset the time to zero and inhibit timing until opened again. Inverted Delay on Release Interval On (Input Controlled) 1 1 2 3 4 72 & 92 - Output relay is energized by the application of input voltage. The time interval is initiated at the same time with the relay de-energizing at the completion of the time interval. 76 & 96 - Same as above. Closing the control switch will have no effect on timing or the state of the relay. 2 3 4 72 & 92 - No Time Delay - Instantly On 76 & 96 - Output relay will energize with the application of the input voltage when the control switch is open. Control switch closing will de-energize the relay. A timing interval will be initiated with the opening of the control switch, at the completion of which the relay willenergize. With the control switch closed upon application of input voltage, the relay will wait until the control switch is opened to initiate a time interval after which the relay will energize. Closing of the control switch during timing will reset the time to zero and inhibit timing until opened again. Interval On (Switch Controlled) Recycler (Initially Off) 1 2 3 4 72 & 92 - Output relay will begin cycling at a 50% duty cycle with the application of input power. The initial state of the relay will be de-energized. 76 & 96 - Same as the above except, closing the control switch will de-energize the relay and inhibit timing until it is once again opened, at which time it will start from zero time. 1 2 3 4 76 & 96 - Output relay is energized by the application of input voltage with the control switch closed or the closing of the control switch with the input applied. Immediately upon either, timing is initiated with the relay de-energizing at the completion of the time interval. Closing the control switch after time out will reset the timer, energize the relay, and initiate another time interval. Closing the control switch during timing will have no effect on timing or the state of the relay. Interval Off Recycler (Initially On) 1 2 3 4 72 & 92 - Output relay will begin cycling at a 50% duty cycle with the application of input power. The initial state of the relay will be energized. 76 & 96 - Same as the above except, closing the control switch will energize the relay and inhibit timing until it is once again opened, at which time it will start from zero time. Dimensions are shown for 1214 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. 1 2 3 4 76 & 96 - Output relay will initially be energized with the application of the input voltage when the control switch is open. Control switch closing will de-energize the relay and start a time interval. At the completion of the time interval, the relay will energize. With the control switch closed upon application of input voltage, a time interval will be initiated after which the relay will energize. Closing of the control switch during timing will have no effect on timing or the state of the relay. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CNM5 series Multifunction Time Delay Relay For Plug-In or Panel Mounting • • • • • • Five timing functions selectable via rotary switch 0.1 sec. to 9,990 hr. timing range Fixed input type (120VAC ± 15%) 10A output relay with DPDT contacts 1/16 DIN style enclosure with 11-pin plug-in base Thumbwheel switches for programming delay time File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Functions Initial Dielectric Strength See the following page for a complete description of timing functions. Between Output Poles: 1,500V rms, 60 Hz. Between Input and Output: 1,500V rms, 60Hz. Input Data @ 25°C Timing Specifications Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.; 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. Timing Adjustment: Digital adjustment via thumbwheel switches. Tolerance: ±0.05% ± 0.04 sec.* Repeatability (Including first cycle of operation.): < ± 0.05% ± 0.04 sec.* Reset Time (power interruption): 45 ms, typ.; 60 ms, max. Minimum Pulse Width, Control: 50 ms. * Timing is synchronized with input voltage frequency. Accuracy is dependent on input voltage frequency. Tolerance shows maximum variation from utility companies. Contact Data @ 25°C Arrangement: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Voltage: 120VAC ± 15%, 60 Hz. Power Requirement: 3VA @ 120VAC. Transient Protection: 13 Joule MOV. Input Voltage & Limits Nominal Voltage Minimum Voltage Maximum Voltage 120VAC 102VAC 138VAC Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -10°C to +55°C. Humidity: 85% relative humidity, non-condensing. Mechanical Data Termination: 11-pin octal style plug. Enclosure: Black plastic 1/16 DIN (48mm x 48mm) case. Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 4.3 oz. (122g) approximate. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Time Delay Relay Accessory Input Voltage Part Number 120VAC CNM5 Outline Dimensions Part Number Name Description SSA-24C667 Mounting Clip Ratchet-fit clip slides onto CNM5 from behind to secure CNM5 in panel mount applications. Mounting Clip Dimensions 1.88 (47.8) .32 (8.1) 2.83 (71.9) SSA-24C667 Mounting Clip 1.88 (47.8) 1.76 (44.7) 3 1 2 S 3.15 (80.0) .560 (14.2) Fits 1.77 x 1.77 (45 x 45) panel cutout. .64 (16.3) Wiring Diagrams (Bottom Views) 2.283 1.970 (58.0) (50.0) 2.047 (52.0) .591 (15.0) 1.654 (42.0) 1.890 (48.0) (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCH** CONTROL 1 11 INPUT Optional Solid State Input Interface 1 11 INPUT **Important: A dry circuit switch is recommended. A "dry circuit" switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1215 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Timer Function Descriptions Repeat: Output relay is turned on at end of programmed time interval which is started by application of input power. Relay stays on for equal time interval, then turns off and cycle is repeated on a free-running basis with equal on and off times until terminated by removal of input power. LED is flashing when output relay is off and on continuously when the relay is on. Applying CONTROL input during timing will have no effect on timing or the state of the relay. LED to show time status. See functional explanation for details. One Shot: Output relay is turned on by applying CONTROL input with input voltage present or application of input voltage with the CONTROL input on. Immediately upon either, timing is initiated with the output relay turning off at the completion of the selected time interval. Applying CONTROL input after time out will reset the timer, turn on the output relay and initiate another time interval. LED is on continuously when output relay is off and flashes when the relay is on. Applying CONTROL input during timing will have no effect on timing or the state of the relay. REPEAT ONE SHOT OFF DELAY INTERVAL ON DELAY 3 1 2 TIME SET 000 TO 999 Off Delay: Output relay is turned on by applying CONTROL input with input voltage present or application of input voltage with the CONTROL input on. The time interval will be started by removing the CONTROL input with the output relay turning off at completion of the time interval. Reapplying the CONTROL during timing will reset the time to zero and inhibit timing until removed. LED is off when CONTROL input is on, flashing during timing and on continuously when the output relay is off. S TIME BASE Interval: Output relay is turned on for a programmed time interval by applying input voltage. LED flashes when output relay is on and is on continuously when the output relay is off. Applying CONTROL input will have no effect on timing or the state of the relay. Time Base: .1 S S .1 M M .1 H H 10 H = = = = = = = 1/10 Seconds Seconds 1/10 Minutes Minutes 1/10 Hours Hours 10 Hours Dimensions are shown for 1216 reference purposes only. Timing Range 0.1 to 99.9 Seconds Timing Range 1 to 999 Seconds Timing Range 0.1 to 99.9 Minutes Timing Range 1 to 999 Minutes Timing Range 0.1 to 99.9 Hours Timing Range 1 to 999 Hours Timing Range 10 to 9990 Hours Dimensions are in inches over (millimeters) unless otherwise specified. On Delay: Output relay is off for a programmed time interval which is started by applying input voltage. LED flashes when output relay is off and is on continuously when the output relay is on. Applying CONTROL input will have no effect on timing or the state of the relay. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT SSF series Programmable Time Delay Relay • • • • • • • 4 user-programmable timing modes 0.1 sec. to 10 hr. programmable timing range Parameters set with recessed screwdriver dials Universal voltage (plug-in relay dependent) 10A DPDT replaceable output relay minimizes downtime Front screw terminals DIN-rail, panel or machine tool track mount File E15631 File LR29186 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Initial Dielectric Strength Modes are user selectable via screwdriver adjustment of recessed 4position selector dial. Modes offered are: On-Delay, Off-Delay, Interval and Latching Interval. Between Coil/Control Switch and Contacts: 1,500VAC for one minute. Input Data @ 25°C Timing Specifications Timing Ranges: 0.1 to 3 / 0.33 to 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. Timing Range Selection: Screwdriver select via recessed 8-position selector dial. Timing Adjustment: Recessed potentiometer adjustment with reference calibrations. Accuracy: Repeat Accuracy: ± 1% ± 0.01 sec. Overall Accuracy: ± 3% ± 0.01 sec. Reset Time: 30 ms. Relay Operate Time: On-Delay and Interval mode: 30 ms. Relay Release Time: Off-Delay, Interval and Latching Interval: 30 ms. (with factory-installed relay). Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC 345VA. Expected Mechanical Life: 10 million operations (with factory-installed relay). Expected Electrical Life: 500,000 operations, min., at rated resistive load( with factory-installed relay). Outline Dimensions 2.67 (68) 0.188 (5) WIDE SLOT FOR #8 OR M4 MACHINE SCREW 2.19 (56) 1.095 (28) 0.342 (9) DIN TRACK MOUNT 3.125 (79) HOLE PATTERN FOR SCREW MOUNT 2 3 1 4 5 6 3.81 (97) 7 8 Voltage: See Ordering Information section for details. Power Requirement: 2W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 24, 48 VAC/VDC 1,000V 480V 120, 240VAC/VDC 3,000V 2500V* * Min. source impedance of 100 ohm@120/240VAC, 3000V <0.1 , sec. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: Panel, DIN-rail, Machine Tool mounting track mounting case with screw terminals. Weight: 5.5 oz. (156g) approximately. Ordering Information SSF | R | Series SSF R = UL Operating Mode 90 Universal Recognized Multiple modes Timer Component On-Delay Off-Delay Interval Latching Interval 9 10 0.343 (9) 6-32 CAPTIVE CLAMP SCREWS Wiring Diagram (Top View) 0.322 (8) 90 | A | Operating Voltage (+10%, –15%) A = 120VAC, 50/60 Hz. B = 240VAC, 50/60 Hz. E = 24VAC, 50/60 Hz. F = 48VAC, 50/60 Hz. N = 48VDC O =24VDC P = 125VDC X = No factoryinstalled relay.† † Voltage determined by customer-supplied relay. Only relays that operate on the above-listed voltages should be used. Timer operation using other relay voltages is not recommended. Authorized distributors are likely to stock the following: SSFR90A SSFR90X Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1217 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT SCF series Programmable Time Delay Relay • • • • • • 4 user-programmable timing modes 0.1 sec. to 10 hr. programmable timing range Parameters set with recessed dials Narrow width saves panel space 10A DPDT output relay Socket can be DIN-rail or back panel mounted File E15631(relay) and E140494 (socket) File LR29186 (relay) and LR29513M7 (socket) Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C Modes are user selectable via screwdriver adjustment of recessed 4position selector dial. Modes offered are: On-Delay, Off-Delay, Interval and Latching Interval. Voltage: See Ordering Information section for details. Power Requirement: 2W, max. Timing Specifications Timing Ranges: 0.1 to 3 / 0.33 to 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. Timing Range Selection: Screwdriver select via recessed 8-position selector dial. Timing Adjustment: External knob potentiometer adjustment with reference calibrations. Accuracy: Repeat Accuracy: ± 1% ± 0.01 sec. Overall Accuracy: ± 3% ± 0.01 sec. Reset Time: 30 ms. Relay Operate Time: On-Delay and Interval mode: 55 ms. Relay Release Time: Off-Delay, Interval and Latching Interval: 40 ms. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC; 345VA. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12VDC 1,000V 240V* 24VAC/VDC 1,000V 240V* 48 VAC/VDC 1,000V 480V* 120 VAC, 125VDC 3,000V 2,500V* 240VAC/VDC 3,000V 2,500V* * Minimum source impedance of 100 ohm. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: 11-pin octal-type plug for use with mating socket. Mount relay in horizontal position (pins horizontal, knob down, LEDs up). Status Indication: Power On LED and Output Contacts LED. Weight: Relay: 3.5 oz. (156g) approx.; Socket: 1.7 oz. (48.3g) approx. Initial Dielectric Strength Between Terminals and Case: 1,000VAC plus twice the nominal voltage for one minute. Outline Dimensions M3 X 0.5 CAPTIVE CLAMP SCREWS .84 (21) CLEARANCE HOLE FOR M4 OR #8 MACHINE SCREW 3.29 (84) 1.38 (35) 1.645 (42) 0.372 (10) 1.42 (36) 0.71 (18) SCF TIMER .21 (5) .109 (3) DIA. ANTI-ROTATION PIN BETWEEN TERMS 10 & 2 Ordering Information RX 90 | | Series SCF | Operating Mode | Plug-In = Multiple Modes | 90 Programmable On-Delay | Off-Delay Timer | Interval | Latching Interval | SCF | Mounting RX = Without Socket RF = With Socket BCSF11SC SOCKET Wiring Diagram (Bottom View) 2 | | | | | | | | A | Output Rating A = 10 Amp B = 5 Amp Output A | | | | | | | | Operating Voltage (+10%, –15%) 2 = DPDT Relay A = 120VAC, 50/60 Hz. / 125VDC B = 240VAC, 50/60 Hz. § E = 24VAC, 50/60 Hz. / 24VDC F = 48VAC, 50/60 Hz. / 24VDC Q = 12VDC § Voltage Option B is only available with 5 Amp output option. Authorized distributors are likely to stock the following: None at present. Dimensions are shown for 1218 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CN1 series On Delay, Time Delay Relay For Plug-In or Panel Mounting • • • • • 0.1 sec. to 9,990 hr. timing range Fixed input type (120VAC ± 15%) 10A output relay with DPDT contacts 1/16 DIN style enclosure with 8-pin plug-in base Thumbwheel switches for programming delay time File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Function Initial Dielectric Strength On Delay – Output relay turns on at the end of a programmed time interval which is started by applying input voltage. LED flashes when output relay is off and is on continuously when the output relay is on. Removal of input voltage turns off output relay. Reapplying input voltage resets the unit. Between Output Poles: 1,500V rms, 60 Hz. Between Input and Output: 1,500V rms, 60Hz. INPUT VOLTAGE N.O. RELAY CONTACTS Input Data @ 25°C ➛ ON OFF ON OFF TIME Voltage: 120VAC ± 15%, 60 Hz. Power Requirement: 3VA @ 120VAC. Transient Protection: 13 Joule MOV. ➛ Timing Specifications Input Voltage & Limits Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.; 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. Timing Adjustment: Digital adjustment via thumbwheel switches. Tolerance: ± 0.05% ± 0.04 sec.* Repeatability (Including first cycle of operation.): < ± .05% ± 0.04 sec.* Reset Time (power interruption): 45 ms, typ.; 60 ms, max. * Timing is synchronized with input voltage frequency. Accuracy is dependent on input voltage frequency. Tolerance shows maximum variation from utility companies. Nominal Voltage Minimum Voltage Maximum Voltage 120VAC 102VAC 138VAC Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -10°C to +55°C. Humidity: 85% relative humidity, non-condensing. Contact Data @ 25°C Arrangement: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Mechanical Data Termination: 8-pin octal style plug. Enclosure: Black plastic 1/16 DIN (48mm x 48mm) case. Sockets: Fits either 27E122 or 27E891 (snap-on) screw terminal sockets. Weight: 4.3 oz. (122g) approximate. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Time Delay Relay Accessory Input Voltage Part Number 120VAC CN1 Name Description SSA-24C667 Mounting Clip Ratchet-fit clip slides onto CN1 from behind to secure CN1 in panel mount applications. Mounting Clip Dimensions Outline Dimensions 1.88 (47.8) Part Number .32 (8.1) SSA-24C667 2.83 (71.9) Mounting Clip 1.88 (47.8) 1.76 (44.7) 3 1 2 S Fits 1.77 x 1.77 (45 x 45) panel cutout. 3.15 (80.0) 2.283 1.970 (58.0) (50.0) 2.047 (52.0) .591 (15.0) 1.654 (42.0) 1.890 (48.0) .64 (16.3) Wiring Diagram (Bottom View) (pins numbered clockwise from keyway) 1 .1 S S .1 M M .1 H H 10 H 8 INPUT Dimensions are shown for reference purposes only. Time Base Dimensions are in inches over (millimeters) unless otherwise specified. = = = = = = = 1/10 Seconds Seconds 1/10 Minutes Minutes 1/10 Hours Hours 10 Hours Timing Range 0.1 to 99.9 Seconds Timing Range 1 to 999 Seconds Timing Range 0.1 to 99.9 Minutes Timing Range 1 to 999 Minutes Timing Range 0.1 to 99.9 Hours Timing Range 1 to 999 Hours Timing Range 10 to 9990 Hours Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1219 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CG series CMOS IC Time Delay Relay • Repeatability to .05% • Choice of timing modes – Delay on operate – Delay on release – Interval on • Knob adjustable • 10A output relay with DPDT contacts • Various models time from 0.5 sec. to 100 min. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Contact Data @ 25°C Timing Modes Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. ON OFF N.O. RELAY CONTACTS ON OFF ➛ INPUT VOLTAGE Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. ➛ TIME Initial Dielectric Strength Delay on release – Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. CONTROL SWITCH ON OFF Input Data @ 25°C N.O. RELAY ON CONTACTS OFF TIME ➛ ➛ Interval on – The relay energizes and timing begins when input voltage is applied. At the end of the time delay period the relay will de-energize. Reset is accomplished by removing, then reapplying, the input voltage. ON OFF N.O. RELAY ON CONTACTS OFF Voltage: 120VAC and 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @25°C Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC DC 120 24 105 20 130 32 Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. ➛ INPUT VOLTAGE Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. TIME ➛ Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -10°C to +55°C. Timing Specifications Timing Ranges: From 0.5 to 5.0 sec. through 10 to 100 min. Timing Adjustment: Knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types:–0, +10% of max. specified at high end of timing range; +0, –10% of min. specified at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 2%, typ.; ± 5%, max. Repeatability (including first cycle of operation): AC: ± 0.1%, typ.; ± 0.5%, max.; but not less than ± 16 ms. DC: ± 0.05% typ.; ± 0.1% max.; but not less than ± 3 ms. Release Time: 30 ms, typ.; 45 ms, max. Recycle Time: AC: 40 ms, typ.; 60 ms, max. DC: 30 ms, typ.; 45 ms, max. Dimensions are shown for 1220 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: Yellow plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 8 oz. (227g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay on Operate Models Voltage 120VAC 24VDC Time Delay on Release Models Adjustment 0.5 to 5 Min. 1 to 10 Min. 5 to 50 Min. 10 to 100 Min. 5 to 50 Min. Wiring Dia. Knob 1 Knob 1 Part Number Voltage CGB-38-70005M CGB-38-70010M CGB-38-70050M CGB-38-70100M 120VAC CGD-38-30050M Time Adjustment Wiring Dia. Part Number Knob 2 CGB-38-78010M CGB-38-78050M 1 to 10 Min. 5 to 50 Min. Interval on Models Voltage Adjustment Wiring Dia. Part Number 120VAC 0.5 to 5 Sec. 1 to 10 Min. Time Knob 1 CGB-38-79005S CGB-38-79010M 24VDC 1 to 10 Min. Knob 1 CGD-38-39010M ➛ Outline Dimensions 2.406 MAX. (61.1) ➛ 2.937 MAX. (74.6) ➛ ➛ ➛ ➛ .56 (14.2) ➛ .60 (15.2) 1.781 MAX. (45.2) ➛ ➛ ➛ ➛ Fig.1 8 Pin ➛ ➛ + INPUT _ (DC POLARITY INDICATED) ➛ ➛ ➛ Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway) EXT. CONT. SW* _ + INPUT (DC POLARITY INDICATED) Fig.2 11 Pin * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: a dry circuit switch is recommemded. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1221 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CD series CMOS IC Time Delay Relay 1% Repeatability Operates from -40°C to +55°C Delay on operate or delay on release timing modes Fixed, knob or resistor adjustable types – Calibrated dial on knob adjustable types • 10A output relay with SPDT or DPDT contacts • Various models time from 0.1 to 180 sec. • • • • File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Initial Dielectric Strength Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. ON OFF N.O. RELAY CONTACTS ON OFF ➛ INPUT VOLTAGE TIME ➛ Input Data @ 25°C Delay on release – Input voltage must be applied continuously to operate the internal relay. When control Input is applied, the relay energizes. When control input is removed, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by reapplying control input. ON OFF N.O. RELAY ON CONTACTS OFF ➛ CONTROL INPUT TIME ➛ Voltage: 24 & 120VAC and 12 through 110VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC 24 120 12 24 48 110 20 105 11 20 41 95 28 130 13 32 55 125 DC Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. Timing Specifications Timing Ranges: From 0.1 to 180 sec. Timing Adjustment: Fixed, external resistor and knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types: ± 5% of max. specified at high end of timing range; min. specified, or less, at low end; ± 10% full scale. Fixed Types: ± 5%. Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 5%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 1%. Release Time: 45 ms, typ.; 60 ms, max. Recycle Time: 45 ms, typ.; 60 ms, max. Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Dimensions are shown for Temperature Range: Storage: -55°C to +85°C. Operating: -40°C to +55°C. Mechanical Data Contact Data @ 25°C 1222 reference purposes only. Environmental Data Dimensions are in inches over (millimeters) unless otherwise specified. Termination: 8- or 11-pin octal style plug. Enclosure: Yellow plastic case. Knob adjustable types have dial scale calibrated in seconds ± 5%. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 8 oz. (227g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay on Operate Models Voltage 120VAC Time Delay on Release Models Adjustment 0.1 to 1 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. 0.3 to 30 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Wiring Dia. Knob Part Number Voltage CDB-38-70001 CDB-38-70002 CDB-38-70003 CDB-38-70006 CDB-38-70004 CDB-38-70005 1 120VAC Time Adjustment 0.1 to 1 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. 0.3 to 30 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Knob Wiring Dia. 3 Part Number CDB-38-70016 CDB-38-70091 CDB-38-70014 CDB-38-70092 CDB-38-70012 CDB-38-70015 120VAC 1 Sec. Fixed CDA-38-70012 120VAC 1 Sec. Fixed 3 CDA-38-70025 120VAC 0.1 to 1 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. Resistor CDF-38-70001 CDF-38-70002 CDF-38-70003 12VDC 180 Sec. Fixed 3 CDC-38-20026 3 Knob 1 CDD-38-30003 CDD-38-30004 CDD-38-30005 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Knob 24VDC 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 24VDC CDD-38-30014 CDD-38-30012 CDD-38-30008 48VDC 0.6 to 60 Sec. Knob 1 CDD-38-40002 Knob 1 110VDC 0.1 to 1 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 2 CDD-38-60004 CDD-38-60001 CDD-38-60002 CDD-38-60003 ➛ Outline Dimensions 2.406 MAX. (61.1) ➛ 2.937 MAX. (74.6) ➛ ➛ ➛ ➛ .56 (14.2) ➛ .60 (15.2) 1.781 MAX. (45.2) ➛ Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway) CONTROL INPUT* _ EXTERNAL RESISTOR + ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ _ INPUT (DC POLARITY INDICATED)** _ INPUT (DC POLARITY INDICATED)** _ SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 1 8 Pin Fig. 2 11 Pin Fig. 3 11 Pin + + + * If control input is applied when supply input is applied, relay will immediately energize. A 50 millisecond minimum control pulse is required. ** Note Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. External Resistor Selection Chart See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1223 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CK series Mid-Priced CMOS IC Time Delay Relay • Choice of timing modes – Delay on operate – Delay on release – Delay on dropout (no input required during timing) – Interval on • Knob or resistor adjustable types • 10A output relay with DPDT contacts • Various models time from 0.1 to 180 sec. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Contact Data @ 25°C Timing Modes Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. ON OFF ON OFF ➛ INPUT VOLTAGE N.O. RELAY CONTACTS ➛ TIME Delay on release – Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. ON OFF N.O. RELAY CONTACTS ON OFF ➛ CONTROL SWITCH TIME ➛ Delay on dropout – The relay operates immediately upon application of input voltage. Timing begins when input voltage is removed. When timing is complete, the relay will de-energize. Reset occurs when input voltage is reapplied. ON OFF ON OFF ➛ INPUT VOLTAGE N.O. RELAY CONTACTS TIME ➛ Interval on (with control switch) – Input voltage must be applied continuously to operate the internal relay. The relay energizes and timing begins when the external switch is closed. At the end of the time delay period the relay will de-energize. Reset is accomplished by opening and reclosing the control switch. ON OFF N.O. RELAY CONTACTS ON OFF TIME Input Data @ 25°C Voltage: 24 & 120VAC and 12 & 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Initiate Time: Delay on dropout timers must have input voltage applied for a minimum of three seconds for dropout function to be guaranteed. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC 24 120 12 24 20 105 11 20 28 130 13 32 DC Environmental Data Timing Ranges: From 0.1 to 180 sec. Timing Adjustment: External resistor and knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types:–0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 5%. Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. Release Time: 60 ms, typ.; 100 ms, max. Recycle Time: 60 ms, typ.; 100 ms, max. Dimensions are shown for Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. ➛ Timing Specifications 1224 reference purposes only. Initial Dielectric Strength Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. ➛ CONTROL SWITCH Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Dimensions are in inches over (millimeters) unless otherwise specified. Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: White plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 6 oz. (170g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay On Release Models Delay On Operate Models Voltage Time 24VAC 0.1 to 10 Sec. 120VAC 0.1 to 10 Sec. 0.6 to 60 Sec. 1.2 to 120 Sec. 1.8 to 180 Sec. Adjustment Wiring Dia. Part Number Knob 1 CKB-38-30010 Knob 1 CKB-38-70010 CKB-38-70060 CKB-38-70120 CKB-38-70180 120VAC 0.1 to 10 Sec. Resistor 2 CKF-38-70010 12VDC 0.1 to 10 Sec. Knob 1 CKD-38-20010 Voltage Time 120VAC 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Adjustment Wiring Dia. Part Number Knob 3 CKB-38-78010 CKB-38-78060 CKB-38-78180 120VAC 24VDC 0.1 to 10 Sec. Resistor 4 CKF-38-78010 0.1 to 10 Sec. Resistor 4 CKH-38-38010 Adjustment Wiring Dia. Part Number Knob 1 CKB-38-37010 CKB-38-37060 Knob 1 Adjustment Wiring Dia. Part Number Knob 3 CKB-38-79010 Delay On Dropout Models Voltage 24VAC 120VAC Time 0.1 to 10 Sec. 0.6 to 60 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.2 to 120 Sec. CKB-38-77010 CKB-38-77060 CKB-38-77120 Interval On Models Voltage Time 120VAC 0.1 to 10 Sec. ➛ Outline Dimensions 2.406 MAX. (61.1) ➛ 2.937 MAX. (74.6) ➛ ➛ ➛ ➛ .56 (14.2) ➛ .60 (15.2) 1.781 MAX. (45.2) ➛ Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway) EXTERNAL RESISTOR EXTERNAL RESISTOR ➛ ➛ INPUT (DC POLARITY INDICATED)** Fig.1 8 Pin Fig. 2 11 Pin Fig. 3 11 Pin _ + ➛ ➛ ➛ INPUT (DC POLARITY INDICATED)** + ➛ ➛ ➛ + CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** _ ➛ + _ ➛ ➛ ➛ ➛ ➛ ➛ ➛ EXTERNAL CONTROL SWITCH* _ CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 4 11 Pin EXTERNAL CONTROL SWITCH* * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. External Resistor Chart See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1225 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CH series Mid- To Low-Priced CMOS IC Time Delay Relay • Choice of timing modes – Delay on operate – Delay on release – Interval on • Fixed or knob adjustable types • 10A output relay with DPDT contacts • Various models time from 1 to 180 sec. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Contact Data @ 25°C Timing Modes Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. INPUT VOLTAGE ON OFF N.O. RELAY ON CONTACTS OFF Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. TIME Initial Dielectric Strength Delay on release – Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. CONTROL SWITCH ON OFF N.O. RELAY ON CONTACTS OFF TIME Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. Input Data @ 25°C Voltage: 24 through 240VAC and 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C Interval on – The relay energizes and timing begins when input voltage is applied. At the end of the time delay period the relay will de-energize. Reset is accomplished by removing, then reapplying, the input voltage. INPUT VOLTAGE ON OFF N.O. RELAY ON CONTACTS OFF Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC 24 120 240 24 20 105 210 20 28 130 260 32 DC Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. TIME Environmental Data Timing Specifications Timing Ranges: From 1 to 180 sec. Timing Adjustment: Fixed and knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types:–0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 5%. Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. Release Time: 125 ms, typ.; 200 ms, max. Recycle Time: 125 ms, typ.; 200 ms, max. Dimensions are shown for 1226 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: White plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 6 oz. (170g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay on Operate Models Voltage Time 24VAC 1 to 10 Sec. 1 to 180 Sec. Delay on Release Models Adjustment Wiring Dia. Part Number Voltage Time Adjustment Wiring Dia. Part Number Knob 1 CHB-38-30001 CHB-38-30003 24VAC 1 to 10 Sec. Knob 3 CHB-38-30011 120VAC 1 to 10 Sec. 1 to 60 Sec. 1 to 180 Sec. Knob 3 CHB-38-70011 CHB-38-70012 CHB-38-70013 Knob 3 Adjustment Wiring Dia. Part Number 120VAC 1 to 10 Sec. 1 to 60 Sec. 1 to 180 Sec. Knob 1 CHB-38-70001 CHB-38-70002 CHB-38-70003 120VAC 10 Sec. Fixed 1 CHA-38-70001 240VAC 1 to 10 Sec. Knob 1 CHB-38-80001 24VDC 1 to 10 Sec. 1 to 60 Sec. 1 to 180 Sec. Knob 1 CHD-38-30001 CHD-38-30002 CHD-38-30003 24VDC 1 to 10 Sec. 1 to 180 Sec. CHD-38-30011 CHD-38-30013 Interval on Models Voltage Time 120VAC 1 to 10 Sec. 1 to 60 Sec. 1 to 180 Sec. Knob 1 CHB-38-70021 CHB-38-70022 CHB-38-70023 24VDC 1 to 10 Sec. Knob 1 CHD-38-30021 ➛ Outline Dimensions 2.406 MAX. (61.1) ➛ 2.937 MAX. (74.6) ➛ ➛ ➛ ➛ .56 (14.2) ➛ .60 (15.2) 1.781 MAX. (45.2) ➛ Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway) Fig. 2 11 Pin ➛ ➛ Fig. 1 8 Pin ➛ ➛ ➛ + INPUT (DC POLARITY INDICATED) ➛ _ + INPUT _ (DC POLARITY INDICATED) EXT SWITCH* ➛ ➛ ➛ ➛ ➛ ➛ EXTERNAL RESISTOR + - AC INPUT Fig. 3 11 Pin * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1227 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CB series CMOS IC Time Delay Relay • Choice of timing modes – Delay on operate – Delay on release – Interval on with or without control switch • Knob adjustable • 10A output relay with SPDT or DPDT contacts • Various models time from 0.1 sec. to 100 min. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Contact Data @ 25°C Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. Arrangements: 2 Form C (DPDT), except 8-pin delay on release model has 1 Form C (SPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. INPUT VOLTAGE ON OFF N.O. RELAY ON CONTACTS OFF TIME Delay on release – Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. CONTROL SWITCH Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. ON OFF N.O. RELAY ON CONTACTS OFF TIME Interval on (without control switch) – The relay energizes and timing begins when input voltage is applied. At the end of the time delay period the relay will de-energize. Reset is accomplished by removing, then reapplying, the input voltage. INPUT VOLTAGE Initial Dielectric Strength ON OFF Input Data @ 25°C Voltage: 24 and 120VAC, and 12 and 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C N.O. RELAY ON CONTACTS OFF TIME Interval on (with control switch) – Input voltage must be applied continuously to operate the internal relay. The relay energizes and timing begins when the external switch is closed. At the end of the time delay period the relay will de-energize. Reset is accomplished by opening and reclosing the control switch. CONTROL SWITCH Maximum Voltage AC 24 120 12 24 20 105 11 20 28 130 13 32 DC Environmental Data Timing Ranges: From 0.1 to 1.0 sec. through 10 to 100 min. Timing Adjustment: Knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types: –0, +30% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 10%. Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. Release Time: 60 ms, typ.; 100 ms, max. Recycle Time: 60 ms, typ.; 100 ms, max. Dimensions are shown for Minimum Voltage TIME Timing Specifications 1228 reference purposes only. Nominal Voltage Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. ON OFF N.O. RELAY ON CONTACTS OFF Voltage Type Dimensions are in inches over (millimeters) unless otherwise specified. Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: White plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 6 oz. (170g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay on Operate Models Voltage Time 24VAC 0.1 to 10 Sec. 1.8 to 180 Sec 120VAC 12VDC Wiring Dia. Part Number Voltage Time Knob 1 CB-1041B-30 CB-1042B-30 24VAC 0.1 to 10 Sec. 1.8 to 180 Sec 0.1 to 1 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 1 to 10 Min. 10 to 100 Min. Knob 0.1 to 10 Sec. Knob 0.1 to 1 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 24VDC Delay on Release Models Adjustment CB-1001B-70 CB-1002B-70 CB-1003B-70 CB-1004B-70 CB-1005B-70 CB-1006B-70 CB-1007B-70 1 1 Knob CB-1047D-20 120VAC 24VDC 0.1 to 10 Sec. 1.8 to 180 Sec. Wiring Dia. Part Number Knob 3 CB-1045B-38 CB-1046B-38 3 5 3 3 CB-1021B-78 CB-1022B-78 CB-1023B-78 CB-1024B-78 Knob 3 CB-1038D-38 CB-1039D-38 Knob Interval on Models CB-1026D-30 CB-1028D-30 CB-1029D-30 CB-1030D-30 1 0.1 to 10 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Adjustment Voltage Time Adjustment Wiring Dia. Part Number 24VAC 0.1 to 10 Sec. Knob 1 CB-1043B-39 120VAC 0.1 to 5 Sec. 0.1 to 10 Sec. 1 to 10 Min. Knob 1 1 1 CB-1011B-79 CB-1014B-79 CB-1018B-79 Knob 1 CB-1034D-39 CB-1036D-39 24VDC 0.1 to 5 Sec. 1.8 to 180 Sec. ➛ Outline Dimensions 2.406 MAX. (61.1) ➛ 2.937 MAX. (74.6) ➛ ➛ ➛ .56 (14.2) ➛ ➛ .60 (15.2) 1.781 MAX. (45.2) ➛ Wiring Diagrams - Bottom Views (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCH* EXTERNAL CONTROL SWITCH* ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ ➛ + _ + _ INPUT (DC POLARITY INDICATED)** CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 1 8 Pin Fig. 3 11 Pin Fig. 5 8 Pin _ + * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1229 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CR series Recycle Time Delay Relay • Individual ON and OFF time adjustment knobs • 10A output relay with DPDT contacts • Various models time from 0.1 to 180 sec. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Initial Dielectric Strength Recycle timing – First delay period begins when input voltage is applied. At the end of the first delay, or “off” period, the relay will operate and the second delay, or “on” period, begins. When the second delay period ends, the relay de-energizes. This recycling sequence will continue until input voltage is removed. When input voltage is removed, the relay will deenergize. Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. INPUT VOLTAGE ON OFF N.O. RELAY CONTACTS ON OFF ➛ 1 TIME ➛➛ TIME 2 ➛➛ 1 TIME ➛ Input Data @ 25°C Voltage: 120VAC and 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C Timing Specifications Timing Ranges: From 0.1 to 180 sec. Timing Adjustment: Knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): -0%, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. Release Time: 60ms, typ.; 100 ms, max. Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC DC 120 24 105 20 130 32 Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. Environmental Data Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Contact Data @ 25°C Mechanical Data Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10 A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Termination: Octal plug. Enclosure: White plastic case with dial scales for reference only. Sockets: Fits either 27E122 or 27E891 (snap-on) 8-pin screw terminal sockets. Weight: 6 oz. (170g) approximately. Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Part Number Outline Dimensions Time Part Number 1.8 to 180 Sec. CRD-48-30180 Wiring Diagram – Bottom View ➛ ➛ ➛ .875 ➛ (22.23) ➛ ➛ (pins numbered clockwise form keyway) ➛ .56 (14.22) ➛ ➛ 1.781 MAX. (45.2) ➛ ➛ 24VDC ➛ .60 (15.2) 3.56 MAX. (90.42) Voltage DC Type CRB-48-70010 CRB-48-70030 CRB-48-70060 CRB-48-70180 ➛ AC Types Time 0.1 to 10 Sec. 120VAC 0.3 to 30 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. ➛ Voltage 1 ➛ ➛ 1.25 (31.75) 8 + INPUT _ (DC POLARITY INDICATED) Fig.1 8 Pin ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. 2.406 MAX. (61.1) Dimensions are shown for 1230 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CL -CU series Compact Time Delay Relay • • • • • • Delay on operate timing mode Fixed, knob or resistor adjustable types 10A output relay with DPDT contacts Variety of mounting options Various models time from 0.1 to 120 sec. No timing cycle interrupt transfer (CL only) File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Contact Data @ 25°C Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. INPUT VOLTAGE ON OFF N.O. RELAY CONTACTS ON OFF ➛ TIME ➛ Initial Dielectric Strength Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. CL Timing Specifications Timing Ranges: From 0.1 to 1.0 sec. through 1.2 to 120 sec. Timing Adjustment: Fixed, external resistor and knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types:–0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 5%. Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 3%. Release Time: 100 ms, typ.; 150 ms, max. Recycle Time: 100 ms, typ.; 150 ms, max. Input Data @ 25°C Voltage: 24 & 120VAC and 12 & 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC 24 120 12 24 20 105 11 20 28 130 13 32 DC CU Timing Specifications Timing Ranges: From 1.0 to 10 sec. through 1.0 to 120 sec. Timing Adjustment: Fixed, external resistor and knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types:–0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 5%. Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 3%. Release Time: 150 ms, typ.; 225 ms, max. Recycle Time: 150 ms, typ.; 225 ms, max. Note: On CU types the switching contact may momentarily transfer if the timing interval is interrupted. CL types have no timing cycle interrupt transfer. Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. Environmental Data Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Mechanical Data Termination: 0.187 in. (4.75mm) quick-connect. Enclosure: Yellow plastic case (see outline drawings for various options). Knob adjustable types have dial scale for reference only. Sockets: Solder, printed circuit and screw terminal sockets available. Weight: 3.5 oz. (99g) approximately. CL Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Voltage Time Adjustment Wiring Dia. Part Number Voltage Time 24VAC 0.1 to 10 Sec. Knob 1 CLB-51-30010 12VDC 0.1 to 10 Sec. 24VAC 0.1 to 10 Sec. Resistor 2 CLF-42-30010 12VDC 10 Sec. 120VAC 0.1 to 10 Sec. 0.3 to 30 Sec. 1.2 to 120 Sec. Knob 1 CLB-51-70010 CLB-51-70030 CLB-51-70120 12VDC 1.2 to 120 Sec. 24VDC 5 Sec. Fixed 1 CLA-41-70003 CLA-41-70030 24VDC 0.1 to 10 Sec. 0.3 to 30 Sec. 0.1 to 10 Sec. Resistor 2 CLF-41-70010 CLF-42-70010 CLF-41-70120 41 style models (e.g. CLA-41-70010) have plain case. 42 style models (e.g. CLF-42-70010) have bracket mount case. 45 style models (e.g. CLH-45-30010) have bracket mount case with test button. 51 style models (e.g. CLB-51-30010) have plain case with knob. 120VAC 120VAC 3 Sec. 30 Sec. 0.1 to 10 Sec. 0.1 to 10 Sec. 1.2 to 120 Sec. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. Adjustment Wiring Dia. Part Number Knob 1 CLD-51-20010 CLC-41-20010 Fixed 1 Resistor 2 CLH-41-20120 Fixed 1 CLC-41-30005 Resistor 2 CLH-41-30010 CLH-41-30030 CLH-45-30010 www.tycoelectronics.com Technical support: 1231 Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B CU Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Voltage Time 24VAC 10 Sec. Adjustment Wiring Dia. Part Number Fixed 1 CUA-41-30010 Resistor 2 CUF-41-30010 CUF-42-30010 1 to 10 Sec. 1 to 10 Sec. 24VAC 1 to 10 Sec. 1 to 30 Sec. 1 to 60 Sec. 1 to 120 Sec. 120VAC Knob 1 Sec. 3 Sec. 3 Sec. 5 Sec. 10 Sec. 10 Sec. 30 Sec. 120 Sec. 120VAC CUB-51-70010 CUB-51-70030 CUB-51-70060 CUB-51-70120 1 Fixed Time 120VAC 1 to 10 Sec. 1 to 10 Sec. 1 to 30 Sec. 1 to 120 Sec. 1 to 120 Sec. Adjustment Wiring Dia. Part Number 2 CUF-41-70010 CUF-42-70010 CUF-41-70030 CUF-41-70120 CUF-42-70120 2 CUH-41-30010 CUH-42-30010 CUH-41-30120 CUH-42-30120 Resistor 1 to 10 Sec. 1 to 10 Sec. 1 to 120 Sec. 1 to 120 Sec. 24VDC CUA-41-70001 CUA-41-70003 CUA-42-70003 CUA-41-70005 CUA-41-70010 CUA-42-70010 CUA-42-70030 CUA-41-70120 1 Voltage Resistor 41 style models (e.g. CUA-41-70010) have plain case. 42 style models (e.g. CUA-42-70010) have bracket mount case. 51 style models (e.g. CUB-51-70010) have plain case with knob. Outline Dimensions 41 Style 51 Style 42 & 45 Style ➛ ➛ ➛ ➛ 1.406 MAX. (35.71) ➛ ➛ ➛ .07 (1.78) ➛ ➛ ➛ .312 TYP. (7.92) .375 (9.53) ➛ ➛ 1.531 MAX. ➛ (38.89) .645 TYP. ➛ (15.88) ➛ ➛ ➛ .625 MAX. (15.88) 1.906 MAX. (48.41) 1.906 MAX. (48.41) 2.500 (63.50) 2.156 MAX. (15.46) ➛ 2.90 MAX. (73.66) 6 7 8 9 A ➛ ➛ ➛ ➛ ➛ .75 ± .015 (19.05 ± .38) ➛ .06 (1.52) Terminal Dimensions 1.406 MAX. (35.71) .187" (4.74mm) Quick Connect/Solder B ➛ .078 ➛ (1.98) ➛ ➛ SEATED HEIGHT ABOVE CHASSIS MOUNTED IN SOCKET : (57.2mm) .125 (3.18) ➛ 5 .078 R TYP. (1.98) .187 ± .002 (4.75 ± .05) ➛ .250 (6.35) HEADER➛ .281 REF. (7.14) THICKNESS 0.20 (.51) ➛ 4 ➛ ➛ 3 ➛ 2 .281 REF. (7.14) ➛ 1 ➛ ➛ ➛ ➛ ➛ .437 (11.10) ➛ ➛ 1.531 MAX. (38.89) ➛ .281 REF. (7.14) ➛ Wiring Diagrams – Bottom Views + INPUT (DC DC POLARITY INDICATED) ** 7 A ➛ 2 5 3 6 ➛ ➛ ➛ ➛ B 1 4 ➛ A ➛ 3 6 9 ➛ ➛ 1 4 7 9 B + INPUT (DC POLARITY INDICATED) ** Fig. 1 Fig. 2 ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. External Resistor Selection Chart See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook. Dimensions are shown for 1232 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT MD0 series Subminiature, On-Delay Time Delay Relay • • • • • • On-delay timing mode Seven user-selectable timing ranges (0.1 sec. to 10 hr.) High accuracy and reliability Exceptional transient protection (ANSI C37.90) 5A DPDT or 4PDT output contacts Universal voltage File E60363 File LR51332 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C On-Delay. Voltage: Universal: 24-240VAC, 50/60 Hz. or 24-125VDC. Power Requirement: 2W, max. Transient Protection: Meets ANSI C37.90 Transient Specification. Environmental Data Temperature Range: Storage: -25°C to +85°C. Operating: -25°C to +60°C. Timing Specifications Timing Ranges: Instantaneous; 0.1 to 1 / 1 to 10 / 10 to 100 sec.; 1 to 10 / 10 to 100 min.; 1 to 10 hr. Timing Range Selection: Screwdriver select via recessed dial on side. Timing Adjustment: Screwdriver adjust via recessed dial with reference calibrations on top. Accuracy: Repeat Accuracy: ± 0.5% Overall Accuracy: ± 1% ± 0.02 sec. Reset Time: 25 ms. Contact Data @ 25°C Mechanical Data Mounting/Termination: MD0 series time delay relays can be socket mounted horizontally or vertically and will operate within repeat accuracy of ± 0.5%. Sockets: Fits either 27E166 or 27E894 (snap-on) screw terminal sockets. Status Indication: Power On LED and Output Contacts LED. Weight: 4 oz. (96g) approximately. Arrangements: 2 Form C (DPDT) or 4 Form C (4PDT). Rating: 5A @ 30VDC or 240VAC, resistive. Expected Electrical Life: 100,000 operations, min., at rated resistive load. Outline Dimensions 3.00 (76.2) Ordering Information .85 (21.6) 2.75 (69.8) 1.05 (26.7) Part Number MD012AU MD014AU Contacts DPDT 4PDT Input Voltage Universal 24-240VAC, 50/60 Hz. or 24-125VDC Authorized distributors are likely to stock the following: MD014AU Wiring Diagrams (Bottom Views) Terminal Base Diagram NOTE: Only necessary terminals are present on DPDT models. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1233 Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AGASTAT SSC series Specification Grade Discrete Plug-in Time Delay Relay • • • • • • On-Delay, Off-Delay and Interval timing modes 13 timing ranges from 0.1 sec. to 60 min. 10A DPDT output contacts Escellent repeatability of ± 1% or better. Exceptional immunity to transients and noise. Wide operating temperature range. File LR29186 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C On-Delay, Off-Delay and Interval. Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12VDC 1,000V 240V* 24VAC/VDC 1,000V 240V* 48 VAC/VDC 1,000V 480V* 120 VAC/VDC 3,000V 2,500V* 240VAC 3,000V 2,500V* * Minimum source impedance of 100 ohm. Timing Specifications Timing Ranges: 6 to 180 cycles; 0.1 to 3 / 0.1 to 10 / 0.33 to 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. (All are +10%, –1% of maximum values). Timing Adjustment: Knob or fixed time (internal fixed resistor) – all models; customer supplied external potentiometer or resistor – On-Delay and Interval models only. Accuracy: Repeat Accuracy: ± 1% ± 0.004 sec. at any combination of operating temperature and voltage. Overall Accuracy: ± 5.25% throughout operating temperature and voltage ranges. Reset Time: 25 ms. (minimum deenergized interval for on-delay or off-delay models, or minimum required closure interval for interval models without affecting accuracy.) Relay Operate Time: Off-Delay mode only: 35 ms. Relay Release Time: On-Delay mode only: 20 ms. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. Initial Dielectric Strength Between Terminals and Case: 1,000VAC plus twice the nominal voltage for one minute. Outline Dimensions .70 (18) 1.97 (50) Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: 8- or 11-pin octal type plug. 8-pin types fit either 27E122 or 27E891, while 11-pin types fit 27E123 or 27E892. Weight: 4 oz. (112g) approximately. Ordering Information SSC | Series SSC Discrete Industrial Timer 01 | | | | | 2 | Output 2 = DPDT Relay Operating Mode 01 = On-Delay 02 = Off-Delay 03 = Interval 3.25 (83) 1.97 (50) Wiring Diagrams (Bottom Views) Insulated, shielded twoconductor cable similar to Belden 8719, 8720 or 8769 required for leads longer than 6 inches. Max. permissble length is 50 feet. A | | | | | | | | | | | | A | A | | | | | | | | | | | | Timing Range A =0 .1 to 3 sec. B = 0.5 to 15 sec. C = 1 to 30 sec. D = 2 to 60 sec. E = 4 to 120 sec. F = 6 to 180 sec. G = 10 to 300 sec. I = 2 to 60 min. K = 3 to 180 cycles L = 0.33 to 10 min. M = 0.5 to 15 min. N = 1 to 30 min. P = 0.1 to 10 min. Operating Voltage Timing Adjustment (+10%, –15%) A = Knob Adjust A = 120VAC, 50/60 Hz. B = External / 120VDC Potentiometer or B = 240VAC, 50/60 Hz. resistor (Operating E = 24VAC, 50/60 Hz. / modes 1 and 3 only). 24VDC F = Fixed Times – F = 48VAC, 50/60 Hz. / Specify time delay 48VDC in seconds per the Q = 12VDC (±10%) following examples: F9.000 = 9 sec. F99.00 = 99 sec. F999.0 = 9999 sec. F1000 = 1000 sec. Off-Delay On-Delay & Interval On-Delay & Interval Authorized distributors are likely to stock the following: Fixed or Knob Adjust Fixed or Knob Adjust External Potentiomer or Resistor Adjust SSC12AAA SSC12ABA Dimensions are shown for 1234 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. SSC12ACA SSC12ADA Specifications and availability subject to change. SSC12AGA SSC12ALA. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AGASTAT SCB/SCC series Specification Grade Discrete Plug-in Time Delay Relay • • • • • • On-Delay, Off-Delay and Interval timing modes 13 timing ranges from 0.1 sec. to 60 min. 10A DPDT output contacts Knob, fixed or external timing adjustment. Rated for pilot duty Premium components ® File LR51332 ® File E60363 File E60363 (SCC only) Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C On-Delay, Off-Delay and Interval. Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms All except 12 & 24 3,000V 2,500 12 & 24 Consult Factory Timing Specifications Timing Ranges: 6 to 180 cycles; 0.1 to 3 / 0.1 to 10 / 0.33 to 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. (All are +5%, –0% of maximum values). Timing Adjustment: Knob or fixed time (internal fixed resistor) – all models; customer supplied external potentiometer or resistor – On-Delay and Interval models only. Accuracy: Repeat Accuracy: ± 0.5% ± 0.004 sec. Overall Accuracy: ± 2% max. Reset Time: 25 ms. Relay Operate Time: Off-Delay mode: 30 ms; Interval mode: 20 ms.. Relay Release Time: On-Delay mode only: 15 ms. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC; 345VA. Same polarity. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. Initial Dielectric Strength Between Terminals and Case: 1,000VAC plus twice the nominal voltage for one minute. Outline Dimensions .70 (18) 1.97 (50) 3.25 (83) 1.97 (50) Wiring Diagrams (Bottom Views) Insulated, shielded twoconductor cable similar to Belden 8719, 8720 or 8769 required for leads longer than 6 inches. Max. permissble length is 50 feet. Off-Delay On-Delay & Interval On-Delay & Interval Fixed or Knob Adjust Fixed or Knob Adjust External Potentiomer or Resistor Adjust Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Environmental Data Temperature Range: Storage: SCB and SCC: -40°C to +85°C. Operating: SCB: -30°C to +65°C; SCC: -30°C to +50°C. Mechanical Data Mounting/Termination: SCB: UL recognized. Optional 8- or 11-pin octal-type sockets may be ordered separately. SCC: 8- or 11-pin octal type sockets supplied with timer. (Must be used to qualify as "UL Listed" device.) Weight: SCB: 5.3 oz. (149g) approx.; SCC: 7.5 oz. (210g) approx. Ordering Information (All "X's" must be included to complete part number) SCB | RX 2XX A 01 | | | | | Operating Mode | | Series SCB Series SCC | 01 = On-Delay | | Discrete 02 = Off-Delay | | | Industrial 03 = Interval | | | Timer | | Output 2XX = DPDT | | Relay | | | Mounting Series SCB RX = 8- or 11-pin | socket (order | separately) | Mounting Series SCC LA = 8-pin socket p/n | BCSA08SC for operating mode 01 or 03 with knob adjust or fixed time. LC = 11-pin socket p/n BCSA11SC for operating mode 02; or 01 or 03 with external potentiometer or resistor. A | Timing Range A =0 .1 to 3 sec. B = 0.5 to 15 sec. C = 1 to 30 sec. D = 2 to 60 sec. E = 4 to 120 sec. F = 6 to 180 sec. G = 10 to 300 sec. I = 2 to 60 min. K = 3 to 180 cycles L = 0.33 to 10 min. M = 0.5 to 15 min. N = 1 to 30 min. P = 0.1 to 10 min. Operating Voltage (+10%, –15%) A = 120VAC, 50/60 Hz. / 120VDC B = 240VAC, 50/60 Hz. E = 24VAC, 50/60 Hz. / 24VDC F = 48VAC, 50/60 Hz. / 48VDC Q = 12VDC XA | | | | | | | | | | | | | Timing Adjustment XA = Knob Adjust XB = External Potentiometer or resistor (Operating modes 1 and 3 only). XF =Fixed Times – Specify time delay in seconds per the following examples: XF9.000 = 9 sec. XF99.00 = 99 sec. XF999.0 = 9999 sec. XF1000 = 1000 sec. Authorized distributors are likely to stock the following: None at present. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1235 Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AGASTAT STA series Specification Grade Discrete Plug-in Time Delay Relay With QC Terminals • On-Delay, Off-Delay, Interval and Accumulating On-Delay timing modes • 13 timing ranges from 0.1 sec. to 48 hr. • 10A DPDT output contacts • Knob, fixed or external timing adjustment. • QC plug-in terminals save space, two LEDs show status ® File E60363 File LR51332 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C On-Delay, Off-Delay, Interval and Accumulating On-Delay. Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Timing Specifications Timing Ranges: 6 to 180 cycles; 0.1 to 3 / 0.5 to 15 / 1 to 30 / 2 to 60 / 4 to 120 / 6 to 180 / 10 to 300 sec.; 0.33 to 10 / 0.5 to 15 / 1 to 30 min.; 1 to 6 / 2 to 48 hr. (All are +5%, –0% of maximum values). Timing Adjustment: Knob or fixed time (internal fixed resistor) – all models; customer supplied external potentiometer or resistor – On-Delay and Interval models only. Accuracy: Repeat Accuracy: ± .5% ± 0.004 sec.. Overall Accuracy: ± 2% throughout operating temperature and voltage ranges. Reset Time: 30 ms. min. (between deenergization and reenergization without affecting accuracy.) Relay Operate Time: Off-Delay mode: 35 ms.; Interval mode: 20 ms. Relay Release Time: On-Delay and Accumulating On-Delay modes: 20 ms. Operating Voltage All except 12 & 24 12 & 24 <0.1 ms <1 ms 3,000V 2,500 Consult Factory Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: Quick connect terminals fit either 27E121 or 27E893 (snap-on) socket (order separately). Status Indication: Power On LED and Output Contacts LED (optional). Weight: 4.2 oz. (119g) approximately. Contact Data @ 25°C Ordering Information Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC; 345VA. Same polarity. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. S STA RX 01 2X A | | | | | | Status | Series STA | Operating Mode | Discrete | 01 = On-Delay | Indication | LEDs Industrial | 02 = Off-Delay | SX == No | LEDs Timer 03 = Interval | 09 = Accumulating | | With Tab-type | On-Delay | | Terms. | | Output 2X = DPDT | | Relay | Mounting Series RX = 11-pin tab-type | header (order | socket | separately) | Initial Dielectric Strength Between Terminals and Case: 1,000VAC plus twice the nominal voltage for one minute. Outline Dimensions 1.500 MAX. (38) 1.390 MAX. (35) .660 MAX. (17) .281 REF. (7) 3.045 (77) (All "X's" must be included to complete part number) Insulated, shielded two-conductor cable similar to Belden 8719, 8720 or 8769 required for leads longer than 6 inches. Maximum permissble length is 50 feet. On-Delay & Interval On-Delay & Interval Fixed or Knob Adjust Fixed or Knob Adjust External Potentiomer or Resistor Adjust Dimensions are shown for 1236 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. XA | Timing Range | A =0 .1 to 3 sec. | B = 0.5 to 15 sec. | C = 1 to 30 sec. | D = 2 to 60 sec. E = 4 to 120 sec. | F = 6 to 180 sec. | G = 10 to 300 sec. | I = 2 to 60 min. | J = 1 to 6 hr. K = 3 to 180 cycles | L = 0.33 to 10 min. | M = 0.5 to 15 min. | N = 1 to 30 min. R = 2 to 48 hr. | Operating Voltage Timing Adjustment (+10%, –15%) XA = Knob Adjust A = 120VAC, 50/60 XB = External Hz. / 120VDC Potentiometer or E = 24VAC, 50/60 resistor (Operating Hz. / 24VDC modes 1 and 3 F = 48VAC, 50/60 only). Hz. / 48VDC XF =Fixed Times – Q = 12VDC Specify time delay in seconds per the following examples: XF9.000 = 9 sec. XF99.00 = 99 sec. XF999.0 = 9999 sec. XF1000 = 1000 sec. Wiring Diagrams (Bottom Views) Off-Delay & Accumulating On-Delay A | Authorized distributors are likely to stock the following: None at present. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT SRC series Specification Grade Repeat Cycle Plug-in Time Delay Relay • • • • • • • Repeat Cycle timing mode Dual knobs for user adjustment of on and off times. 13 timing ranges from 0.1 sec. to 60 min. 10A DPDT output contacts Exceptional immunity to line transients and noise Premium components enhance reliability Superior reset time of 24 msec. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data @ 25°C Repeat Cycle: Application of line voltage starts the pre-set OFF-time period Upon expiration of the period, the output relay is energized, its contacts transfer, and the pre-set ON-time period begins. At the end of this period the output relay is deenergized, and a new cycle begins. The OFF and ON cycles continue until power is removed. To reset the timer, input voltage must be removed for at least 25 ms. Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12VDC 1,000V 240V* 24VAC/VDC 1,000V 240V* 48 VAC/VDC 1,000V 480V* 120 VAC/VDC 3,000V 2,500V* 240VAC 3,000V 2,500V* * Minimum source impedance of 100 ohm. Timing Specifications Timing Ranges: OFF time and ON time ranges need not be the same. 6 to 180 cycles; 0.1 to 3 / 1 to 10 / 0.5 to 15 / 1 to 30 / 2 to 60 / 4 to 120 / 6 to 180 / 10 to 300 sec.; 0.33 to 10 / 0.5 to 15 / 1 to 30 / 2 to 60 min. (All are +10%, –1% of maximum values). Timing Adjustment: Two internal potentiometers with external knobs. Accuracy: Repeat Accuracy: ± 1% ± 0.004 sec.. Overall Accuracy: ± 2.25% max. Reset Time: 25 ms. max. (between deenergization and reenergization without affecting accuracy.) Relay Operate Time: 20 ms. Relay Release Time: 15 ms. Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. Initial Dielectric Strength Between Terminals & Case and Mutually Isolated Contacts: 1,480VAC. Outline Dimensions 1.97 (50) .40 (10) 3.7 MAX. (94) 1.97 (50) Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: Quick connect terminals fit either 27E121 or 27E893 (snap-on) socket (order separately). Weight: 5.3 oz. (149g) approximately. Ordering Information SRC | 7 2 A | | | Series SRC | Output | Repeat | 2 = DPDT | Cycle Relay | | Timer. | | | Operating Mode 7= Repeat Cycle | | | | | | | C | C | | | | | | | | | | A | Timing Range Timing Off-Time Adjustment A =0 .1 to 3 sec. A = Dual Knob B = 0.5 to 15 sec. Adjust C = 1 to 30 sec. D = 2 to 60 sec. E = 4 to 120 sec. F = 6 to 180 sec. G = 10 to 300 sec. I = 2 to 60 min. K = 3 to 180 cycles L = 0.33 to 10 min. Timing Range M = 0.5 to 15 min. On-Time N = 1 to 30 min. P = 0.1 to 10 sec. A =0 .1 to 3 sec. B = 0.5 to 15 sec. Operating Voltage C = 1 to 30 sec. (+10%, –15%) D = 2 to 60 sec. A = 120VAC, 50/60 E = 4 to 120 sec. Hz. / 120VDC F = 6 to 180 sec. B = 240VAC, 50/60 G = 10 to 300 sec. Hz. I = 2 to 60 min. E = 24VAC, 50/60 K = 3 to 180 cycles Hz. / 24VDC L = 0.33 to 10 min. F = 48VAC, 50/60 M = 0.5 to 15 min. Hz. / 48VDC N = 1 to 30 min. Q = 12VDC P = 0.1 to 10 sec. Wiring Diagram (Bottom View) Authorized distributors are likely to stock the following: None at present. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1237 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT SST series Industrial Grade Discrete Plug-in Time Delay Relay • • • • • • On-Delay, Off-Delay, Interval, One Shot & Repeat modes Time delays to 120 min. Fast setting with time calibrated knobs. Superior transient protection. Rugged construction with 8- or 11-pin plug. Flame retardant housing. File E15631 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Mechanical Data On-Delay, Off-Delay, Interval, One Shot (Latching Interval) or Repeat Cycle. Mounting/Termination: On-Delay, Interval and Repeat types have 8- pin octal plug that fits either 27E122 or 27E891 socket. Off-Delay and One Shot types have 11-pin octal-type plug that fits 27E123 or 27E892. Sockets must be orderd separately. Weight: 4 oz. (112g) approximately. Timing Specifications Timing Ranges: Nine ranges spanning 0.1 sec. to 120 min. Timing Adjustment: Knob adjust. Accuracy: Repeat Accuracy: ± 1%. Overall Accuracy: ± 5%. Reset Time: 50 ms., max., (25 ms typ.) for on-delay and interval; 300 ms, max., for off-delay and one shot; 500 ms, max., for repeat type. Relay Operate Time: 50 ms. Relay Release Time: 30 ms. Ordering Information SST1 – On Delay Types SST2 – Off Delay Types Input Time Range Part No. Input Time Range Part No. 120 VAC 0.1 - 10 sec. 0.6 - 60 sec. 1.8 - 180 sec. 3 - 300 sec. 18 sec. - 30 min. 36 sec. - 60 min. SST12AAA SST12ACA SST12ADA SST12AEA SST12AGA SST12AHA 120 VDC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. 18 sec. - 30 min. 36 sec. - 60 min. SST22AAA SST22ADA SST22AEA SST22AGA SST22AHA 24 VAC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. SST12EAA SST12EDA SST12EEA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST22EAA SST22EDA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST22OAA SST22ODA Between Contacts, Line Inputs and Control Circuits: 1,500V RMS, minimum, at 60 Hz. 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. SST12OAA SST12ODA SST12OEA 12 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST22QAA SST22QDA Input Data @ 25°C 12 VDC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. SST12QAA SST12QDA SST12QEA Contact Data @ 25°C Arrangements: 2 Form C (DPDT). Rating: 10A @ 120/240VAC, resistive; 1/3 HP @ 120/240VAC, 50/60 Hz. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 500,000 operations, min., at rated resistive load. Initial Dielectric Strength Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12 & 24 VAC/VDC 860V 208V* 120 VAC 2,580V 2,150V* * Minimum source impedance of 100 ohm. Environmental Data Temperature Range: Storage: -23°C to +71°C. Operating: -23°C to +54°C. Outline Dimensions 2.0 MAX. (50.8) SQUARE .812 MAX. (20.6) 3.20 MAX. (81.3) 4.60 MAX. (116.8) SST4 – One Shot* Types SST3 – Interval Types Input Time Range Part No. Input Time Range Part No. 120 VAC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. 36 sec. - 60 min. SST32AAA SST32ADA SST32AEA SST32AHA 120 VDC 24 VAC 0.1 - 10 sec. 1.8 - 180 sec. SST32EAA SST32EDA 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. 18 sec. - 30 min. 36 sec. - 60 min. SST42AAA SST42ADA SST42AEA SST42AGA SST42AHA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST32OAA SST32ODA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST42EAA SST42EDA 12 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST32QAA SST32QDA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST42OAA SST42ODA 12 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST42QAA SST42QDA SST7 – Repeat Cycle Types Input Time Range Part No. 120 VDC 0.1 - 10 sec. 1.8 - 180 sec. 3 - 300 sec. 18 sec. - 30 min. 36 sec. - 60 min. SST72AAA SST72ADA SST72AEA SST72AGA SST72AHA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST72EAA SST72EDA 24 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST72OAA SST72ODA 12 VDC 0.1 - 10 sec. 1.8 - 180 sec. SST72QAA SST72QDA Wiring Diagrams (Bottom Views) * Also known as Latching Interval Authorized distributors are likely to stock the following: None at present. Dimensions are shown for 1238 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT SCE series Specification Grade Discrete Plug-in True Off-Delay Time Delay Relay • • • • • ® True Off-Delay timing modes Six time delays from 0.1 sec. to 10 min. 10A SPDT or 5A DPDT output contacts. Excellent repeat accuracy – typically better than ± 1%. 8--pin octal plug. File E15631 File LR51332 CAUTION: If unit has not been energized for several months, apply operating voltage for 20 minutes prior to initial time delay. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Initial Dielectric Strength True Off-Delay – Upon application of operating voltage (min. 100ms), output relay contacts transfer. When operating voltage is removed, the time delay period is initiated. At the end of the delay period, output relay contacts release. If operating voltage is reapplied prior to expiration of the delay period, the delay will be cancelled and output relay contacts will remain transferred. Timing Specifications Timing Ranges: 0.1 to 3 / 0.5 to 15 / 1 to 30 / 4 to 120 / 10 to 300 sec.; 0.33 to 10 min. Timing Adjustment: Knob adjustment - Internal potentiometer with external knob adjustment. Maximum time calibrated with +10%, –0% of values shown below at rated voltage, at 68°F. Fixed time – internal fixed resistor. Accuracy: Repeat Accuracy: ± 1. Overall Accuracy: ± 5%. Reset Time: 30 ms. min. Relay Operate Time: 30 ms. Input Data @ 25°C Voltage: See Ordering Information section for details. Power Requirement: 750mw. Transient Protection: 1,000V plus twice rated voltage for 0.1 ms. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Mounting/Termination: 8-pin octal plug fits either 27E122 or 27E891 (snap-on) socket (order separately). Weight: 4 oz. (112g) approximately. Ordering Information Contact Data @ 25°C Arrangements: 1 Form C (SPDT) and 2 Form C (DPDT). Rating: 1 Form C: 10A @ 120/240VAC, resistive; 1/3 HP @ 120VAC; 345VA @ 120VAC; 1/4 HP @ 240VAC; 275VA @ 240VAC. Same polarity. 2 Form C: 5A @ 28VDC or 120/240VAC, resistive; 1/6 HP @ 120/ 240VAC; 200VA @ 120/240VAC. Same polarity. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 200,000 operations, min., at rated resistive load. Outline Dimensions .60 (15) 1.97 (50) Between Terminals and Case and relay contacts and active circuitry: 1,480VAC for one minute. 3.25 (83) SCE | R X 2 2 | | | | | | Series SCE Output Rating Output True | W = 10A (SPDT) | 1 = SPDT (W) Off-delay | X = 5A (DPDT) | 2 = DPDT (W) Timer | | Agency Recognition R = UL recognized Operating Mode 2 = True Off-Delay C | Timing Range A =0 .1 to 3 sec. B = 0.5 to 15 sec. C = 1 to 30 sec. E = 4 to 120 sec. G = 10 to 300 sec. L = 0.33 to 10 min. A | | | | | | | | | | | | | Operating Voltage (+10%, –15%) A = 120VAC, 50/60 Hz. / 125VDC E = 24VAC, 50/60 Hz. / 24VDC Timing Adjustment F = 48VAC, 50/60 A = Knob Adjust Hz. / 48VDC F = Fixed Times – Specify time delay in seconds per the following examples: XF9.000 = 9 sec. XF99.00 = 99 sec. XF999.0 = 9999 sec. XF1000 = 1000 sec. 1.97 (50) Wiring Diagrams (Bottom Views) Fixed Time Or Knob Adjust A | | | | | | | | | Fixed Time Or Knob Adjust Authorized distributors are likely to stock the following: None at present. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1239 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTM-1 series Specification Grade, On-Delay Timing Module • • • • • • On-delay timing mode Timing from 1 to 1000 sec. 1A solid state SPST-NO output 0.25" (6.35) quick connect terminals Universal voltage: 24 to 240VAC/VDC Rated to 10 million operations File E60363 File LR51332 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C On-Delay – VTM-1 in-line timing module is wired in series with the load circuit. Time delay is initiated when power is applied to the series network. Connecting a resistor across the center terminals provides tamper-proof setting of time delay from 1-1000 sec. Operating Voltage: Universal: 24-240VAC/VDC (19-288VAC/VDC). Current: 2mA (max.) required to operate timer regardless of output state. Power Requirement: 3W, max. Transient Protection: MOV across input 2,000V for 11µs on line side of load. Timing Specifications Timing Ranges: 1 to 1,000 sec. Timing Adjustment: Time delay is set by connecting an appropriately rated resistor or potentiometer between the center two terminals. As supplied, the unit provides a nominal 1 second delay. Add 10k ohm of resistance for every additional second of delay required. For example: 5 seconds = 40k ohms; 10 seconds = 90k ohms. Accuracy: Repeat Accuracy: ± 2% Reset Time: 100 ms, max., in the timing or time-out condition. Output Switch Data Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -30°C to +65°C. Mechanical Data Screw mount in horizontal or vertical position through built-in mounting ears. Termination: 0.250 in (6.35) quick connect terminals for input line, load output and timing resistor connection. Weight: 3 oz. (84g) approximately. Mounting: Arrangement: 1 Form A (SPST-NO). Rating: 5A, inductive, at nominal operating voltage. Inrush: Not to exceed 10A for one cycle. Max. Leakage Current: 4mA rms. Expected Electrical Life: 10,000,000 operations at rated load. Initial Dielectric Strength Between Active Terminals and Outside of Case: 1,480VAC for one min. Outline Dimensions Ordering Information Part Number VTM-1 Mode On-Delay Input Voltage 24-240VAC or VDC Authorized distributors are likely to stock the following: VTM-1 Wiring Diagram Notes: 1. Do not operate timer without connecting load in series with line voltage. 2. For a time delay of 1 second, connect a jumper across the center two terminals. Dimensions are shown for 1240 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AGASTAT VTM1 series On-Delay Timing Module • • • • • On-delay timing mode Reliable solid state timing circuitry. Excellent transient protection. Compact design. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C On-Delay. Voltage: 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC. Power Requirement: 3W, max. Timing Specifications Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12, 24 VAC/VDC 860V* 208V* 120 VAC/VDC 2,580V 2,150V* Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 0.5 to 10 / 3 to 60 min. Timing Adjustment: External resistor or potentiometer. An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: (T ) Treq - Tmin x 1,000,000 ohms max - Tmin Accuracy: Repeat Accuracy: ± 1% Overall Accuracy: ± 2% at R = 1 megohm. Reset Time: 100 ms, max., before time-out; 10 ms, max., after time-out. Rt = * Min. source impedance of 100 ohm. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Output Switch Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 10,000,000 operations at rated load. Initial Dielectric Strength Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 3 oz. (84g) approximately. Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions Ordering Information 2.00 (50.8) VTM1 | 1.25 (31.8) .885 (22.5) Series VTM1 On-Delay Timing Module 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW A | Input Voltage A = 120VAC/VDC E = 24VAC/VDC Q = 12VAC/VDC CD | Time Range CD = 0.5 - 10 sec. DD = 3 - 60 sec. FD = 0.5 - 10 min. GD = 3 - 60 min. .250 (6.35) X .032 (.813) QUICK CONNECTS Wiring Diagram LOAD INPUT VOLTAGE An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: Rt = Dimensions are shown for reference purposes only. ( Treq - Tmin Tmax - Tmin ) Authorized distributors are likely to stock the following: VTM1ECD VTM1EDD x 1,000,000 ohms Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1241 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTMA1 series On-Delay Timing Module With Internal Potentiometer • • • • • • On-delay timing mode Discrete voltage or universal type. Internal potentiometer for timing adjustment. Reliable solid state timing circuitry. Excellent transient protection. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C On-Delay. Voltage: ± 10% 120VAC/VDC (unfiltered DC must be full-wave rectified) or 24 to 240 VAC/VDC. Power Requirement: 250mW during timing; 3W, max. after time out. Timing Specifications Timing Ranges: VMTA1ULA only: 24 to 480 sec. All others: 0.5 to 10 / 3 to 60 /15 to 300 sec.; 3 to 60 min. Timing Adjustment: Internal potentiometer. Accuracy: Repeat Accuracy: ± 5% Overall Accuracy: Max. Time: –0%, +10%. Min. Time: –30%, +10%. Reset Time: 250 ms, max., before time-out; 10 ms, max., after time-out. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 24 VAC/VDC 860V* 208V* 120/240 VAC/VDC 2,580V 2,150V* * Min. source impedance of 100 ohms. Current Drain: 2mA, Max. Output Switch Data Environmental Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 10,000,000 operations at rated load. Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Initial Dielectric Strength Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions amd Wiring Diagram 2.00 .388 (50.8) (9.85) .427 (10.8) Ordering Information 1.25 (31.8) .885 (22.5) Part Number VTMA1ACA VTMA1ADA VTMA1ACA Time Range 0.5 to 10 sec. 3 to 60 sec. 24 to 480 sec. Input Voltage 120VAC or VDC 24-240VAC or VDC TIME DELAY ADJUSTMENT 2.00 (50.8) INPUT VOLTAGE L1 .170 DIA (4.32) ACCEPTS #8 SCREW LOAD .250 (6.35) X .032 (.813) QUICK CONNECTS L2 Authorized distributors are likely to stock the following: None at present. Dimensions are shown for 1242 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTMR1 series On-Delay Timing Module With Internal Potentiometer, Relay Output • • • • • • On-delay timing mode 8A SPDT relay output. Internal potentiometer for timing adjustment. Reliable solid state timing circuitry. Excellent transient protection. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C On-Delay. Voltage: ± 10% 120VAC/VDC. Power Requirement: 3.5VA, max. Timing Specifications Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 120 VAC/VDC 2,580V 2,150V* Timing Ranges: 15 to 300 sec. Timing Adjustment: Internal potentiometer. Accuracy: Repeat Accuracy: ± 5% max. (0.25% typ.) Overall Accuracy: Max. Time: –0%, +10%. Min. Time: –30%, +10%. Reset Time: 250 ms, max. * Min. source impedance of 100 ohms. Current Drain: 30mA, Max. Output Contact Data Environmental Data Arrangement: 1 Form C (SPDT). Rating: 8A, resistive, at nominal operating voltage. Expected Mechanical Life: 10,000,000 operations. Expected Electrical Life: 100,000 operations. Temperature Range: Storage: -40°C to +70°C. Operating: -40°C to +70°C. Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Initial Dielectric Strength Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions and Wiring Diagram .278 (7.06) .763 (19.4) 2.00 (50.8) Ordering Information OUTPUT RELAY Part Number VTMR1AEA Time Range 15 to 300 sec. Input Voltage 120VAC OUTPUT RELAY .286 TIME (7.26) DELAY ADJUST 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW INPUT VOLTAGE .250 (6.35) X .032 (.813) QUICK CONNECTS .885 (22.5) 1.25 (31.8) Authorized distributors are likely to stock the following: None at present. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1243 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTM2 series Off-Delay Timing Module • • • • • Off-delay timing mode Reliable solid state timing circuitry. Excellent transient protection. Compact design. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C Off-Delay. Voltage:(±10%): 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC. Power Requirement: 4W, with rated load. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12, 24 VAC/VDC 860V* 208V* 120 VAC/VDC 2,580V 2,150V* Timing Specifications Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 3 to 60 min. Timing Adjustment: External resistor or potentiometer. An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: (T ) Treq - Tmin x 1,000,000 ohms max - Tmin Accuracy: Repeat Accuracy: ± 1% Overall Accuracy: ± 2% at R = 1 megohm. Reset Time: 50 ms, max. Rt = * Min. source impedance of 100 ohms. Current Drain: Less than 5mA. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Output Switch Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 10,000,000 operations at rated load. Initial Dielectric Strength Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions Ordering Information VTM2 | 1.25 (31.8) 2.00 (50.8) .885 (22.5) Series VTM2 Off-Delay Timing Module 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW A | Input Voltage A = 120VAC/VDC E = 24VAC/VDC Q = 12VAC/VDC CD | Time Range CD = 0.5 - 10 sec. DD = 3 - 60 sec. GD = 3 - 60 min. .250 (6.35) X .032 (.813) QUICK CONNECTS Wiring Diagram POLARITY SHOWN FOR DC MODELS LOAD 1 7 START SWITCH 6 5 Rt 2 INPUT VOLTAGE 3 Dimensions are shown for 1244 reference purposes only. 4 An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: Rt = ( Treq - Tmin Tmax - Tmin ) Authorized distributors are likely to stock the following: None at present. x 1,000,000 ohms Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTM3 series Interval Timing Module • • • • • Interval timing mode Reliable solid state timing circuitry. Excellent transient protection. Compact design. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C Interval. Voltage:(±10%): 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC. Power Requirement: 4W, with rated load. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12, 24 VAC/VDC 860V* 208V* 120 VAC/VDC 2,580V 2,150V* Timing Specifications Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 3 to 60 min. Timing Adjustment: External resistor or potentiometer. An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: (T ) Treq - Tmin x 1,000,000 ohms max - Tmin Accuracy: Repeat Accuracy: ± 1% Overall Accuracy: ± 2% at R = 1 megohm. Reset Time: 50 ms, max. Rt = * Min. source impedance of 100 ohms. Current Drain: Less than 5mA. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Output Switch Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 100,000,000 operations at rated load. Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Initial Dielectric Strength Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions Ordering Information VTM3 | 1.25 (31.8) 2.00 (50.8) .885 (22.5) Series VTM3 Interval Timing Module 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW A | Input Voltage A = 120VAC/VDC E = 24VAC/VDC Q = 12VAC/VDC CD | Time Range CD = 0.5 - 10 sec. DD = 3 - 60 sec. GD = 3 - 60 min. .250 (6.35) X .032 (.813) QUICK CONNECTS Wiring Diagram POLARITY SHOWN FOR DC MODELS LOAD 1 5 2 4 Rt INPUT VOLTAGE An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: 3 Rt = Dimensions are shown for reference purposes only. ( Treq - Tmin Tmax - Tmin ) Authorized distributors are likely to stock the following: None at present. x 1,000,000 ohms Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1245 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTM4 series One Shot (Latching Interval) Timing Module • • • • • One shot (latching interval) timing mode Reliable solid state timing circuitry. Excellent transient protection. Compact design. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C One Shot (Latching Interval). Voltage:(±10%): 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC. Power Requirement: 4W, with rated load. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12, 24 VAC/VDC 860V* 208V* 120 VAC/VDC 2,580V 2,150V* Timing Specifications Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 0.5 to 10 / 3 to 60 min. Timing Adjustment: External resistor or potentiometer. An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: (T ) Treq - Tmin x 1,000,000 ohms max - Tmin Accuracy: Repeat Accuracy: ± 1% Overall Accuracy: ± 2% at R = 1 megohm. Reset Time: 50 ms, max. Rt = * Min. source impedance of 100 ohms. Current Drain: Less than 5mA. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Output Switch Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 100,000,000 operations at rated load. Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Initial Dielectric Strength Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions Ordering Information 1.25 (31.8) 2.00 (50.8) .885 (22.5) 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW VTM4 | Series VTM4 One Shot (Latching Interval) Timing Module A | Input Voltage A = 120VAC/VDC E = 24VAC/VDC Q = 12VAC/VDC CD | Time Range CD = 0.5 - 10 sec. DD = 3 - 60 sec. FD = 0.5 - 10 min. GD = 3 - 60 min. .250 (6.35) X .032 (.813) QUICK CONNECTS Wiring Diagram POLARITY SHOWN FOR DC MODELS LOAD 1 7 2 INPUT VOLTAGE 3 Dimensions are shown for 1246 reference purposes only. START SWITCH 6 5 4 An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following R t formula: Rt = ( Treq - Tmin Tmax - Tmin ) Authorized distributors are likely to stock the following: None at present. x 1,000,000 ohms Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT VTM7 series Repeat Cycle Timing Module • • • • • • Repeat cycle timing mode Independently adjustable On and Off times. Reliable solid state timing circuitry. Excellent transient protection. Compact design. Flame retardant, solvent resistant housing. File E60363 File LR33434 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Mode Input Data @ 25°C Repeat Cycle. Voltage:(±10%): 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC. Power Requirement: 4W, with rated load. Transient Protection: Non-repetitive transients of the following magnitudes will not cause spurious operation of affect function and accuracy. Operating Voltage <0.1 ms <1 ms 12, 24 VAC/VDC 860V* 208V* 120 VAC/VDC 2,580V 2,150V* Timing Specifications Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 3 to 60 min. Timing Adjustment: External resistor or potentiometer. An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: (T ) Treq - Tmin x 1,000,000 ohms max - Tmin Accuracy: Repeat Accuracy: ± 1% Overall Accuracy: ± 2% at R = 1 megohm. Reset Time: 500 ms. Rt = * Min. source impedance of 100 ohms. Current Drain: Less than 5mA. Environmental Data Temperature Range: Storage: -40°C to +85°C. Operating: -40°C to +65°C. Output Switch Data Arrangement: Solid state 1 Form A (SPST-NO). Rating: 1A, inductive, at nominal operating voltage. Expected Electrical Life: 100,000,000 operations at rated load. Initial Dielectric Strength Mechanical Data Mounting: Panel mount with one #8 screw. Termination: 0.250 in (6.35) quick connect terminals. Weight: 4 oz. (112g) approximately. Between Terminals and Mounting: 3,000VAC rms. Between Input and Output: 1,500VAC rms. Outline Dimensions Ordering Information 1.25 (31.8) 2.00 (50.8) VTM7 | .885 (22.5) Series VTM7 Repat Cycle Timing Module 2.00 (50.8) .170 DIA (4.32) ACCEPTS #8 SCREW A | Input Voltage A = 120VAC/VDC E = 24VAC/VDC Q = 12VAC/VDC CD | Time Range CD = 0.5 - 10 sec. DD = 3 - 60 sec. GD = 3 - 60 min. .250 (6.35) X .032 (.813) QUICK CONNECTS Wiring Diagram POLARITY SHOWN FOR DC MODELS LOAD 1 7 Rt OFF 6 5 Rt 2 INPUT VOLTAGE 4 ON An external resistance of 1 megohm is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula: 3 Rt = Dimensions are shown for reference purposes only. ( Treq - Tmin Tmax - Tmin ) Authorized distributors are likely to stock the following: None at present. x 1,000,000 ohms Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1247 Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AGASTAT 7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Series 7000 Timing Relays are also manufactured to MIL-SPEC requirements, conforming to requirements of MIL-C-2212F (SHIPS) with the exception of MILS-901. Consult factory for ordering information. Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Design Features On-delay model 7012 (delay on pickup) • Available in on-delay, true off-delay, and on/off-delay. • Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. • Oversize time-calibrated adjustment knobs, serrated with high-resolution markings visible from all angles makes the timer easy to set timers. • Inherent transient immunity. • Standard voltages from 6-550VAC and 12-550VDC (special voltages available.) • Available in 2-pole or 4-pole models. • Numerous enclosure options: explosion proof, dust tight, watertight, hermetically-sealed, NEMA 1. • Auxiliary timed and instantaneous switches can be added for greater switching flexibility. • Many mounting options: Surface mount, Panel mount, Octal plug-in mounting. • Options: quick-connect terminals, dial stops, and transient protection module. • Easy-to-reach screw terminals, all on the face of the unit, clearly identified. • Modular assembly - timing head, coil assembly and switchblock are all individual modules, with switches field-replaceable. Applying continuous voltage to the coil (L1-L2) starts a time delay lasting for the preset time. During this period the normally closed contacts (3-5 and 4-6) remain closed. At the end of the delay period the normally closed contacts break and the normally open contacts (1-5 and 2-6) make. The contacts remain in this transferred position until the coil is deenergized, at which time the switch instantaneously returns to its original position. De-energizing the coil, either during or after the delay period, will recycle the unit within 50 msec. It will then provide a full delay period upon re-energization, regardless of how often the coil voltage is interrupted before the unit has been permitted to "time-out" to its full delay setting. Design & Construction There are three main components of Series 7000 Timing Relays: Calibrated Timing Head uses no needle valve, recirculates air under controlled pressure through a variable orifice to provide linearly adjustable timing. Patented design provides instant recycling, easy adjustment and long service life under severe operating conditions. Precision-Wound Potted Coil module supplies the initial motive force with minimum current drain. Total sealing without external leads eliminates moisture problems, gives maximum insulation value. Snap-Action Switch Assembly - custom-designed over-center mechanism provides greater contact pressure up to transfer time for positive, no flutter action. Standard switches are DPDT arrangement, with flexible beryllium copper blades and silver-cadmium oxide contacts. Special "timing-duty" design assures positive wiping action, sustained contact pressure and greater heat dissipation during long delay periods. Each of these subassemblies forms a self-contained module which is then assembled at the factory with the other two to afford a wide choice of operating types, coil voltages, and timing ranges. The squared design with front terminals and rear mounting permits the grouping of Series 7000 units side-by-side in minimum panel space. Auxiliary switches may be added in the base of the unit, without affecting the overall width or depth. Off-delay model 7022 (delay on dropout) Applying voltage to the coil (for at least 50 msec) will instantaneously transfer the switch, breaking the normally closed contacts (1-5 and 2-6), and making the normally open contacts (3-5 and 4-6). Contacts remain in this transferred position as long as the coil is energized. The time delay begins immediately upon de-energization. At the end of the delay period the switch returns to its normal position. Re-energizing the coil during the delay period will immediately return the timing mechanism to a point where it will provide a full delay period upon subsequent deenergization. The switch remains in the transferred position. Operation Two basic operating types are available. “On-Delay” models provide a delay period on energization, at the end of which the switch transfers the load from one set of contacts to another. Deenergizing the unit during the delay period immediately recycles the unit, readying it for another full delay period on re-energization. In "Off-Delay" models the switch transfers the load immediately upon energization, and the delay period does not begin until the unit is deenergized. At the end of the delay period the switch returns to its original position. Re-energizing the unit during the delay period immediately resets the timing, readying it for another full delay period on de-energization. No power is required during the timing period. In addition to these basic operating types, "Double-Head" models offer sequential delays on pull-in and drop-out in one unit. With the addition of auxiliary switches the basic models provide two-step timing, pulse actuation for interlock circuits, or added circuit capacity. NOTE: Seismic & radiation tested E7000 models are available. Consult factory for detailed information. Dimensions are shown for 1248 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. To increase the versatility of the basic timer models, auxiliary switches may be added to either on-delay or off-delay types. They switch additional circuits, provide two-step timing action, or furnish electrical interlock for sustained coil energization from a momentary impulse, depending on the type selected and its adjustment. Because of their simple attachment and adjustment features, they can be installed at the factory or in the field, by any competent mechanic. All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC. A maximum of one Code T or two Code L auxiliary switches may be added to each relay. The L or LL switch is available with on-delay relays only. The T switch is available with both the on-delay and off-delay relays. Auxiliary Switch Options for On-Delay Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) 1. Energizing coil begins time delay and transfers auxiliary switch. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. Auxiliary switch is nonadjustable. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Auxiliary switch options To increase the versatility of the basic timer models, auxiliary switches may be added to either on-delay or off-delay types. They switch additional circuits, provide two-step timing action, or furnish electrical interlock for sustained coil energization from a momentary impulse, depending on the type selected and its adjustment. Because of their simple attachment and adjustment features, they can be installed at the factory or in the field, by any competent mechanic. All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC. A maximum of one Code T or two Code L auxiliary switches may be added to each relay. The L or LL switch is available with on-delay relays only. The T switch is available with both the on-delay and off-delay relays. Auxiliary Switch Options for On-Delay Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) 1. Energizing coil begins time delay and transfers auxiliary switch. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. Auxiliary switch is nonadjustable. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) 1. Energizing coil begins time delay. 2. After first delay auxiliary switch transfers. 3. Main switch transfers after total preset delay. 4. De-energizing coil resets both switches instantly. First delay is independently adjustable, up to 30% of overall delay. (Recommended maximum 100 seconds.) Auxiliary Switch Options for Off-Delay In these models the same auxiliary switch provides either two-step timing or instant transfer action, depending on the adjustment of the actuator. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) 1. Energizing coil transfers main and auxiliary switches instantly. 2. De-energizing coil begins time delay. 3. After first delay auxiliary switch transfers. 4. Main switch transfers after total preset delay. First delay is independently adjustable, up to 30% of overall delay. (Recommended maximum 100 seconds.) Instant Transfer (Auxiliary Switch Code L, maximum of 1 per relay.) 1. Energizing coil transfers main and auxiliary switches instantly. 2. De-energizing coil resets auxiliary switch and begins time delay. 3. Main switch transfers after total preset delay. Auxiliary switch is factory adjusted to give instant transfer operation, but may be easily adjusted in the field to provide two-step timing. On-delay, off-delay model 7032 (double head) The Double Head model provides delayed switch transfer on energization of its coil, followed by delayed resetting upon coil deenergization. Each delay period is independently adjustable. In new circuit designs or the improvement of existing controls now using two or more conventional timers, the Double Head unit offers distinct advantages. Its compact design saves precious panel space, while the simplified wiring reduces costly interconnection. On-delay, off-delay model 7032 (double head) With the addition of an extra switch block at the bottom of the basic unit, this version of the Series 7000 offers four pole switch capacity with simultaneous timing or two-step timing. The two-step operation is achieved by factory adjustment to your specifications. For two-step operation, a maximum timing ratio between upper and lower switches of 3:2 is recommended. Once adjusted at the factory, this ratio remains constant regardless of changes in dial settings. (Ex: If upper switch transfer is set on dial at 60 sec., minimum time on lower switch should be 40 sec.) This Series 7000 unit offers many of the performance features found in basic models - voltage ranges, timing and switch capacities are virtually identical. Four pole models add approximately 1-1/4" to the maximum height of the basic model, approximately 1/8" to the depth. They are designed for vertical operation only. Surge/transient protection option Features • Protect electronic control circuits from voltage transients generated by the timer coil. • Fast response to the rapidly rising back E.M.F. • High performance clamping voltage characteristics. • UL recognized, (except varistor and coil together). • Timer NOT polarity sensitive. The Surge/Transient Protection Option protects electronic control circuits from transients and surges which are generated when the timer coil is activated. Built with a minimum of moving parts, the unit provides a fast response to rapidly rising voltage transients. The accurate, precision-made device is not polarity sensitive and permits the user to initiate, delay, sequence and program equipment actions over a wide range of applications under the most severe operating conditions. It consists of a specially modified coil case, varistor, varistor cover, terminal extensions and cup washers so that normal terminations can be used. The varistor will not affect the operating characteristics of the 7000 Timer. The varistor has bilateral and symmetrical voltage and current characteristics and therefore can be used in place of the back-to-back zener diodes. This characteristic also means that the coil will not be polarity sensitive. Transient Suppressor Option "V" Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1249 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified). Operating Modes: Model 7012/7014: On-delay (delay on pick-up). Model 7022/7024: Off-delay (delay on drop-out). Model 7032: On-delay, off-delay (double head). Timing Adjustment: Timing is set by simply turning the calibrated dial to the desired time value. In the zone of approximately 25° separating the high and low end of timing ranges A,D,E, and K, instantaneous operation (no time delay) will occur. All other ranges produce an infinite time delay when the dial is set in this zone. Models 7014 and 7032 are available with letter-calibrated dials only. The upper end of the time ranges in these models may be twice the values shown. Linear Timing Ranges: Models 7012, Models 7014, Code 7022, 7024 7032 A .1 to 1 Sec. .2 to 2 Sec. B .5 to 5 Sec. .7 to 7 Sec. C 1.5 to 15 Sec 2 to 20 Sec. D 5 to 50 Sec. 10 to 100 Sec. E 20 to 200 Sec. 30 to 300 Sec. F 1 to 10 Min. 1.5 to 15 Min. H 3 to 30 Min. 3 to 30 Min. I 6 to 60 Min. Not Avail. J 3 to 120 Cyc. Not Avail. K 1 to 300 Sec. Not Avail. Repeat Accuracy: For delays of 200 seconds or less: 7012*, 7022, 7024: +5% 7014*: +10% 7032: +15% For delays greater than 200 seconds: 7012*, 7022, 7014*, 7024: +10% 7032: +15% * The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6 to 60 min.) time ranges or Model 7014 with H time range will be approx. 15% longer than subsequent delays due to coil temperature rise. Reset Time: 50 msec. (except model 7032) Relay Release Time: 50 msec. for on-delay models (7012/7014) Relay Operate Time: 50 msec. for off-delay models (7022/7024) Operating Voltage Coil Data (for DPDT) Coil Part # Code Letter Rated Voltage 7000 A B C D E F G H I J K 120 240 480 550 24 AC 12 6 208 L 7010 DC M N O P Q R S T U V W Y Z X 28 48 24 125 12 60 250 550 16 32 96 6 220 Operating* Voltage Range @ 60Hz 102-132 204-264 408-528 468-605 20.5-26.5 110 220 Operating Voltage Range @50Hz 93.5-121 187-242 127 240 108-140 204-264 Rated Voltage 10.2-13.2 5.1-6.6 178-229 Dual Voltage Coil (Combines A&B) Special AC Coils (L1, L2, etc.) 22.4-30.8 38.4-52.8 19.2-26.4 100-137.5 9.6-13.2 48-66 200-275 440-605 12.8-17.6 25.8-35.2 76.8-105.6 4.8-6.6 176-242 Special DC Coils (X1, X2, etc.) *Four pole Models: Operational voltage range 90% to 110% for AC units; 85% to 110% for DC units. Minimum operating voltages are based on vertically mounted 7012 units. 7012 horizontally mounted or 7022 vertically or horizontally mounted units will operate satisfactorily at minimum voltages approximately 5% lower than those listed. AC units drop out at approximately 50% of rated voltage. DC units drop out at approximately 10% of rated voltage. All units may be operated on intermittent duty cycles at voltages 10% above the listed maximums (intermittent duty - maximum 50% duty cycle and 30 minutes "on" time.) Surge/Transient Protection Option Characteristics (DC Timers Only) Coil Voltage Max Excess Max De-energization Nominal (DC) Energy Capacity (Joule) Transient Voltage 12 V 24 V 28 V 32 V 48 V 60 V 96 V 110 V 125 V 220 V 250 V 0.4 J 1.8 J 1.8 J 2.5 J 3.57 J 6J 10 J 10 J 10 J 17 J 17 J 48 V 93 V 93 V 135 V 145 V 250 V 340 V 340 V 340 V 366 V 366 V Surge Life Applied 100,000 times continuously with the interval of 10 seconds at room temperature. Below 68 VAC: 12A; Above 68 VAC: 35A Temperature Range Operating: -22°F to +167°F (-30°C to + 75°C) Storage: -40°F to +167°F (-40°C to +75°C) Output/Life Contact Ratings: Contact Capacity in Amps (Resistive Load) Contact Min. 100,000 Min. 1,000,000 Voltage Operations Operations 30 VDC 15.0 7.0 110 VDC 1.0 0.5 120 V 60Hz 20.0 15.0 240 V 60Hz 20.0 15.0 480 V 60Hz 12.0 10.0 10 Amps Resistive, 240 VAC 1/4 Horsepower, 120 VAC/240VAC (per pole) 15 Amps 30 VDC (per pole) 5 Amps, General Purpose, 600VAC (per pole) Dielectric: Withstands 1500 volts RMS 60Hz between terminals and ground. 1,000 volts RMS 60 Hz between non-connected terminals. For dielectric specification on hermetically sealed models consult factory. Insulation Resistance: 500 Megohms with 500VDC applied. Temperature Range: Operating: -20°F to +165°F (-29°C to 74°C) Storage: -67°F to +165°F (-55°C to 74°C) Temperature Variation: Using a fixed time delay which was set and measured when the ambient temperature was 77°F (25°C), the maximum observed shift in the average of three consecutive time delays was -20% at -20°F (-29°C) and +20% at 165°F (74°C). Mounting/Terminals: Normal mounting of the basic unit is in a vertical position, from the back of the panel. A front mounting bracket is also supplied with each basic unit, for installation from the front of the panel. All units are calibrated for vertical operation. Basic models (7012, 7022) may also be horizontally mounted, and will be adjusted accordingly when Accessory Y1 is specified in your order. Standard screw terminals (8-32 truss head screws supplied) are located on the front of the unit, with permanent schematic markings. Barrier isolation is designed to accommodate spade or ring tongue terminals, with spacing to meet all industrial control specifications. The basic Series 7000 may also be panel mounted with the addition of a panelmount kit that includes all necessary hardware and faceplate. This offers the convenience of "out-front" adjustment, with large calibrated dial skirt knob. The faceplate and knob blend with advanced equipment and console designs, while the body of the unit and its wiring are protected behind the panel. Other mounting options include plug-in styles and special configurations to meet unusual installation requirements. Contact factory for details. Power Consumption: Approximately 8 watts power at rated voltage . Approximate Weights: Models 7012, 7022 . . . . . . . 2 lbs. 4 ozs. 7014, 7024 . . . . . . . 2 lbs. 10 ozs. 7032 . . . . . . . . . . . . 3 lbs. 5 ozs. Weight may vary slightly with coil voltage. See next column for more coil data. Dimensions are shown for 1250 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Outline Dimensions (Dimensions in inches). Models 7012, 7022 Panel mount Option "X" Dimensions are shown for reference purposes only. Model 7032 Models 7014, 7024 Surge/Transient Protection Option Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1251 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Ordering Information Typical Part No. ➤ 70 1 2 A D GZ 1. Basic Series: 70 = 7000 series electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3 = On-delay, off-delay (double head) 3. Contact Arrangement: 2 = 2PDT (2 form C) **4 = 4PDT (4 form C) 4. Coil Voltage: AC Coils A = 120VAC, 60 Hz.; 110VAC, 50Hz. B = 240VAC, 60 Hz.; 220VAC, 50Hz. C = 480VAC, 60 Hz. D = 550VAC, 60 Hz. E = 24VAC, 60 Hz. F = 127VAC, 50 Hz. G = 240VAC, 50Hz. H = 12VAC, 60 Hz. K = Dual voltage (combines A & B) L = Special AC coils (L1, L2, etc.) 5. Timing Range: Models 7012, 7022 & 7024 A = .15 to 3 sec. B = .5 to 5 sec. C = 1.5 to 15 sec. D = 5 to 50 sec. E = 20 to 200 sec. F = 1 to 10 min. H = 3 to 30 min. I = 6 to 60 min. J = 3 to 120 cyc. K = 1 to 300 sec. DC Coils M = 28VDC N = 48VDC O = 24VDC P = 125VDC Q = 12VDC R = 60VDC S = 250VDC T = 550VDC U = 16VDC V = 32VDC W = 96VDC Y = 6VDC Z = 220VDC X = Special DC coils (X1, X2, etc.) †Models 7014 & 7032 For model 7032 specify separate time range code for each head. Example: AB. Any two ranges may be selected. A = .2 to 2 sec. B = .7 to 7 sec. C = 2 to 20 sec. D = 10 to 100 sec. E = 30 to 300 sec. F = 1.5 to 15 min. H = 3 to 30 min. 6. Options: A1 = Single quick-connect terminals (note 4). A2 = Double quick-connect terminals (note 4). B = Plug-in connectors (note 4). GZ = Enclosure with bottom knockouts (note 1). H2 = Hermetically sealed enclosure, 8 pin solder (notes 1 & 4). H3 = Hermetically sealed enclosure, 8 pin octal (notes 1 & 4). H4 = Hermetically sealed enclosure, 8 screw terminal block (notes 1 & 4). *H6 = Hermetically sealed enclosure, 11 pin solder (notes 1 & 4). *H7 = Hermetically sealed enclosure, 11 pin octal (notes 1 & 4). *H8 = Hermetically sealed enclosure, 11 screw terminal block (notes 1 & 4). l1 = Tamper-proof Cap, opaque black (Cannot be combined with Option X). l2 = Tamper-proof Cap, transparent (Cannot be combined with Option X). K = Explosion-proof Enclosure (note 1). L = Auxiliary Switch, instant transfer. 7012 only (notes 2 & 6). LL = Two Aux. Switches, instant transfer. On Model 7014 Factory Installed Only. (notes 2 & 6) M = Dust-tight Gasketing (notes 4 & 5). P = Octal Plug Adapter. Can be combined only with options l1,l2. M, S, X, or Y1. (note 4). S = Dial Stops. T = Auxiliary Switch, two-step timing (notes 2 & 6). V = Transient/Surge Protection (for DC coil voltage only). W = Watertight Enclosure (note 1). X = Panelmount includes hardware and adjustment for horizontal operation (note 4) Y1 = Horizontal calibration, for horizontal operation without panelmounting (note 4). Y2 = Horizontal calibration, with Compensating Spring for vertical operation (note 4). Notes: 1. Cannot be combined with B, P or X Options 2. Cannot be combined with B, P or Y2 Options 3. Cannot be combined with GZ, H, l1, l2, K, W or Y1 Options 4. Not Avail. on 4-Pole Models 5. Not Available with L, T or LL options. 6. Not Available on hermetically sealed units. * Sized to accommodate one L or T Auxiliary Switch ** Not available on On-Delay, Off-Delay (Double Head) model. † Available with letter calibrated dials only. Upper end of time range may be twice the value shown †† 120 cycles = 2 sec. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. 7012AA 7012AB 7012AC 7012AD 7012AE 7012AF 7012AH 7012AK 7012ACL Dimensions are shown for 1252 reference purposes only. 7012BC 7012NC 7012PA 7012PB 7012PC 7012PD 7012PF 7012PJ 7012PK 7012PKX 7012PJX 7022AA 7022AB 7022AC 7022AD 7022AE 7022AF 7022AH Dimensions are in inches over (millimeters) unless otherwise specified. 7022AI 7022AJ 7022AKT 7022BC 7022BK 7022PA 7022PB 7022PC 7022PK Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Ordering options – can only be orderd as factory installed options (Dimensions, where shown, are in inches.) A1 – Single Quick-Connect Terminals A2 – Double Quick-Connect Terminals B – Plug-In Connectors Use with Accessory “C” or “D” below. GZ – Total Enclosure H – Hermetically Sealed Enclosure I – Tamper-Proof Cover With knockouts for bottom connection. 3.16" W x 3.84" D x 7.63"H K – Explosion proof Enclosure L – Auxiliary Switch LL – Auxiliary Switch (Meets requirements for Class I, Groups C&D locations). 7.50"W x 6.00" D x 10.38" H M – Dustight P – Octal Plug Adapter S – Dial Stops Gasket Gasket V – Transient/Surge Protection T – Auxiliary Switch W – Watertight Enclosure (NEMA-4) 4.75" W x 4.44" D x 9.75" H Transient Protection X – Panelmount Kit Mounting hardware included. Accessories (Not available for 7032 models) Plug-In Receptacle (Accessory D) Plug-In Receptacle (Accessory C) Screw Terminals Catalog No. 700137. For use with "B" Option Quick Connect Terminals Catalog No. 700141. For use with "B" Option. Ordering options can only be ordered as factory installed options. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1253 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT 2100 series Miniature Electropneumatic Timing Relay Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Design Features • High Repeat Accuracy over voltage and temperature extremes • Hermetically sealed units are designed for high shock and vibration applications • Instant recycling – easy linear adjustment • Exclusive Dial Head adjustment – no needle valves • Delay ranges from milliseconds to 3 minutes • DPDT contacts Design & Construction Sealed patented timing head circulates air under controlled pressure through a variable orifice to provide adjustable timing. Circular-path Dial Head principle replaces traditional needle valve. Snap-action switch assembly provides sustained contact pressure during timing cycles. Specially designed over center mechanism assures flutterfree load transfer after extended delay periods. Precision-wound solenoid assembly supplies the basic motive force when the control circuit is closed. These assemblies are mounted in a rigid self-supporting framework within a steel enclosure. This rugged construction assures permanent alignment of all operating members, the key to this unit's long trouble-free operation. Operation Series 2112 (On-Delay) - Applying rated voltage to the solenoid coil starts the preset time delay. At the end of the delay period the NC contacts break and the NO contacts make. Contacts remain in this position until the coil is deenergized, when the switch instantaneously returns to its original position. De-energizing the coil, either during or after the delay period, will immediately (within 25 msec.) recycle the unit. It will then provide another full delay period on re-energization. Series 2122 (Off-Delay) - Applying rated voltage to the coil for at least 75 msec. (for accurate timing) will instantaneously transfer the switch, breaking the NC contacts and making the NO contacts. Contacts remain in this position as long as the coil is energized. The preset time delay period begins as soon as the coil is de-energized, at the end of which the switch returns to its original position. No power is required during the timing period. Reenergizing the coil, either during or after the delay period, will immediately start a new cycle with full delay period. Repeat Accuracy: NORMAL VERTICAL POSITION +5% at 25°C; +7% at 85°C; +8% at -55°C. The average time between -55°C and 85°C will be within +20% of the average @ 25°C with a proportionally reduced effect at lesser extremes. In extremely short delay settings an additional 8 msec. variation may result on AC models due to "half cycle" alternating current effect. Setting Tolerance: Factory time setting, when specified, subject to additional +5% tolerance. Position Sensitivity: HORIZONTAL POSITION: Approximately 5% increase from the initial time in the vertical position. INVERTED POSITION: Approximately 10% increase from the initial time in the vertical position. Reset Time: 2112 Series: 25 msec.; 2122 Series: 75 msec. Relay Release Time: 25 msec. (2112 Series) Relay Operate Time: 75 msec. (2122 Series) Operating Voltage: Coil Data Nominal Resistance Operating Ohms Code Voltage ±10% M N P R Y 12VDC 28VDC 48VDC 110VDC 125VDC Code 30 131 500 3200 3380 S S T U Nominal Operating Voltage Resistance Ohms ±10% 120V 60 Hz 190 (2112 Series) 120V 60Hz 285 (2122 Series) 240V 60Hz 765 115V 400Hz 2600 Transients: Insensitive to transients of +1500 VAC for 10 milliseconds Dielectric: 1000V RMS @ 60Hz between non-connected terminals. Contact Rating (DPDT Contacts): 30V DC 110V DC 120V 60Hz 120V 400Hz 240V 60Hz Inductive (Amps) 2 .75 3 2 1.5 Resistive (Amps) 10 1 10 10 5 Based on 100,000 operations electrical, 1,000,000 mechanical. Inductive and capacitive load should not have inrush currents that exceed five times normal operating load. Ambient Temperature Range: -55°C to +85°C Weight: Maximum, any unit - 17 ozs. Mounting/Terminals: Chassis mounting tabs, octal plugs and external (-4) or internal (-5) adjustment. Panel mounting back plate, internal adjustment, and solder hook terminals (-9). Operation (Listed values at nom. voltage, 25°C unless noted). Operating Mode: 2112: On-delay (delay on pull-in); 2122: Off-delay (delay on drop-out) Timing Adjustment: All standard models offer easy linear adjustment over one of nine timing ranges listed below. For applications requiring frequent readjustment, the external knob model with calibrated dial is recommended. For tamper-proof installation or where readjustment is infrequent, the internal key model may be preferred. This model requires removal of the cover plate for timing adjustment. Hermetically sealed models provide a slotted adjusting screw under the cap nut on the top cover. Timing Ranges: Code Range Code Range A B C D E F .03 to .1 sec. .1 to .3 sec. .15 to 1.0 sec. .375 to 3.0 sec. .75 to 10.0 sec. 1.0 to 30.0 sec. G H J K L 2.0 to 60.0 sec. 5.0 to 120.0 sec. 5.0 to 180.0 sec. 1.5 to 30.0 cycles 3.0 to 120.0 cycles Dimensions are shown for 1254 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. --4 --5 --9 These are minimum standards; where more severe environmental conditions must be met, please consult the factory. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Outline Dimensions for Industrial Models (Dimensions in inches. Multiply by 25.4 to obtain millimeters.) Ordering Information for Industrial Models Typical Part No. ➤ 21 1 2 D 4 N B 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting 4= Unsealed External Knob Octal Plug Chassis Mount 5= Unsealed Internal Key Octal Plug Chassis Mount 9= Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. None at present. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1255 Refer to inside back cover. Catalog 1308242 Issued 3-03 AGASTAT Specifications for MIL-Spec and Hermetically Sealed Models Dielectric: In accordance with specification MIL-R6106E (ASG). Also withstands 1,000 Volts RMS at 60 Hz between non-connected terminals. Agastat timing relays perform to military specifications in Patriot missiles. Other: Agastat Miniature Timing Relays also conform to applicable Mil-Spec. requirements covering: Moisture Ozone Humidity Sunshine Sand/Dust Acoustic Noise Salt Spray Prolonged Storage Outline Dimensions for MIL-Spec and Hermetically Sealed Models (In inches. Multiply by 25.4 for millimeters). 8 pin solder hook or MS/AN Connector 8 pin solder hook or MS/AN Connector Panel Mount —9 Panel Mount —H1, —H3 Octal Plug (with internal adjustment or external adjustment knob Octal Plug (with internal adjustment or external adjustment knob Chassis Mount —H2 Chassis Mount —4, —5 Ordering Information for MIL-Spec and Hermetically Sealed Models Typical Part No. ➤ 21 1 2 D H1 N B 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting H1 = Hermetically Sealed External Screw Solder Hook Panel Mount Plate H2 = Hermetically Sealed External Screw Octal Plug Chassis Mount H3 = Hermetically Sealed External Screw “AN” Connector Panel Mount Plate 4= Unsealed External Knob Octal Plug Chassis Mount 5= Unsealed Internal Key Octal Plug Chassis Mount 9= Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. U = 115VAC, 400 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. None at present. Dimensions are shown for 1256 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover.