Motor Starting Solutions
Transcription
Motor Starting Solutions
Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete Range of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection... Type 1 or 2 coordination guaranteed between contactors and short-circuit protection devices (manual motor starters or fuses). Comprehensive Range... Connection accessories available for each type of wiring diagram or assembly. Time/Cost Savings... Connecting link No cable preparation required and wiring time reduced. Secure Connection... Contactor No risk of fitting or wiring errors. Simple Construction... Easy assembly and fitting of products. Direct-On-Line Starters Mounting plate Electronic timer Manual motor starter Contactors and interlock unit Auxiliary contacts Connecting link Contactors and interlock unit Connection set Connection set Thermal overload relay Star-delta Starters Reversing Starters 0/0 1SBC141158C0201 Motor Starting Solutions Open Type Version in Kit Form Contents General Information Direct-On-Line Starting of 3-phase Asynchronous Motors ............................................. 4 Star-Delta Starting of 3-phase Asynchronous Motors .................................................... 5 Motor Rated Operational Powers and Currents ............................................................... 6 Utilization Categories ....................................................................................................... 7 Coordination with Short-Circuit Protection Devices ........................................................ 8 Starters Protected by Manual Motor Starter Direct-On-Line Starters ................................................................................................... 10 Reversing Starters ........................................................................................................... 16 Wiring Diagrams .............................................................................................................. 22 Dimensions ...................................................................................................................... 24 Starters Protected by Manual Motor Starter with Bus-bar System "smissline-S" Direct-On-Line and Reversing Starters up to 11 kW ....................................................... 32 Starters Protected by Thermal Overload Relay Direct-On-Line Starters ................................................................................................... 34 Reversing Starters ........................................................................................................... 34 Star-Delta Starters without interlock unit ......................................................................... 36 Star-Delta Starters with interlock unit .............................................................................. 38 Wiring Diagrams .............................................................................................................. 40 Dimensions ...................................................................................................................... 46 Accessories Main Accessories ............................................................................................................ 57 Connecting Links, Connection Sets and Mounting Plates for Direct-On-Line and Reversing Starters ............................................................................ 58 Connection Sets for Star-Delta Starters .......................................................................... 59 1 1SBC101001C0201 Coil Voltage and Thermal Overload Relay Codes How to use the selection tables Starters protected by manual motor starter The tables page 10 up to 21 show for coordination type 1 and 2, the most usual combinations between MS.. manual motor starters and a.c. operated A.. contactors according to AC-3 motor powers, for Direct-On-Line and Reversing starters. Select in the tables the MS.. manual motor starter, contactor and accessory codes necessary to assemble your starter. To complete the code of the contactors, please see the table below. Starters protected by thermal overload relay The tables page 34 up to 39 show the most usual combinations between a.c. operated A.. contactors and TA..DU thermal overload relay according to AC-3 motor powers, for Direct-On-Line, Reversing or Star Delta starters. Select in the tables the contactor, thermal overload relay and accessory codes necessary to assemble your starter. For complete coordination tables type 1 and 2, see www.abb.com/lowvoltage and click on Online Product Selection Tools. To complete the code of the contactors and the selected thermal overload relay, please see the tables below. a.c. coil voltage code for completing contactor order codes Setting Range for completing thermal overload relay order codes Voltage V - 50Hz Voltage V - 60Hz (1) Code 24 24 8 1 0.1 ... 0.16 TA 25 DU 0.16 1SAZ 211 201 R1005 26 28 1 6 0.16 ... 0.25 TA 25 DU 0.25 1SAZ 211 201 R1009 1SAZ 211 201 R1013 Setting range A Type TA 25 DU Order code 28 32 1 7 0.25 ... 0.4 TA 25 DU 0.4 42 42 8 2 0.4 ... 0.63 TA 25 DU 0.63 1SAZ 211 201 R1017 42 48 2 0 0.63 ... 1.0 TA 25 DU 1.0 1SAZ 211 201 R1021 48 48 8 3 1.0 ... 1.4 TA 25 DU 1.4 1SAZ 211 201 R1023 60 60 7 3 1.3 ... 1.8 TA 25 DU 1.8 1SAZ 211 201 R1025 100 100 ... 110 7 4 1.7 ... 2.4 TA 25 DU 2.4 1SAZ 211 201 R1028 105 110 ... 127 2 6 2.2 ... 3.1 TA 25 DU 3.1 1SAZ 211 201 R1031 110 110 ... 120 8 4 2.8 ... 4.0 TA 25 DU 4.0 1SAZ 211 201 R1033 110 ... 115 115 ... 127 8 9 3.5 ... 5.0 TA 25 DU 5.0 1SAZ 211 201 R1035 120 140 2 9 4.5 ... 6.5 TA 25 DU 6.5 1SAZ 211 201 R1038 125 ... 127 150 3 0 6.0 ... 8.5 TA 25 DU 8.5 1SAZ 211 201 R1040 175 208 3 4 7.5 ... 11 TA 25 DU 11 1SAZ 211 201 R1043 190 220 3 6 10 ... 14 TA 25 DU 14 1SAZ 211 201 R1045 210 240 4 0 13 ... 19 TA 25 DU 19 1SAZ 211 201 R1047 220 ... 230 230 ... 240 8 0 18 ... 25 TA 25 DU 25 1SAZ 211 201 R1051 230 ... 240 240 ... 260 8 8 24 ... 32 (1) TA 25 DU 32 1SAZ 211 201 R1053 230 ... 240 277 4 2 18 ... 25 TA 42 DU 25 1SAZ 311 201 R1001 380 ... 400 400 ... 415 8 5 22 ... 32 TA 42 DU 32 1SAZ 311 201 R1002 400 ... 415 415 ... 440 8 6 29 ... 42 TA 42 DU 42 1SAZ 311 201 R1003 400 440 5 0 18 ... 25 TA 75 DU 25 1SAZ 321 201 R1001 400 ... 415 480 5 1 22 ... 32 TA 75 DU 32 1SAZ 321 201 R1002 415 ... 440 440 ... 460 8 7 29 ... 42 TA 75 DU 42 1SAZ 321 201 R1003 440 500 5 3 36 ... 52 TA 75 DU 52 1SAZ 321 201 R1004 500 600 5 5 45 ... 63 TA 75 DU 63 1SAZ 321 201 R1005 550 – 5 6 60 ... 80 TA 75 DU 80 1SAZ 321 201 R1006 660 ... 690 – 5 8 29 ... 42 TA 80 DU 42 1SAZ 331 201 R1003 – 690 5 9 36 ... 52 TA 80 DU 52 1SAZ 331 201 R1004 45 ... 63 TA 80 DU 63 1SAZ 331 201 R1005 60 ... 80 TA 80 DU 80 1SAZ 331 201 R1006 65 ... 90 TA 110 DU 90 1SAZ 411 201 R1001 80 ... 110 TA 110 DU 110 1SAZ 411 201 R1002 (1) Code in bold for dual frequency coils. (1) With terminal block DX 25: 1 x 16 mm2 0/1 1SBC101001C0201 General Information for Ordering Ordering Details (examples) MS 116-0.25 1SAM 250 000 R1002 When placing an order, give either the Order Code or Type for all products to create motor starter. According to the products, these are completed with: coil voltage for the contactors, setting range for the thermal O/L relays. This is why the Order codes and Types figuring in the "Ordering Details" tables have boxes and to be completed. BEA 16/116 1SBN 081 406 R1000 A 9-30-10 24V-50Hz 1SBL 141 001 R8110 Direct-On-Line Starters - Tables for ordering details, pages 12 ... 15 TE5S-120 1SBN 020 010 R1002 PM 26-23 1SBN 091 407 R1000 MS 116-0.40 1SAM 250 000 R1003 A 9-30-10 110V-50Hz 1SBL 141 001 R8410 VE 5-1 1SBN 030 110 R1000 CA 5-10 1SBN 010 010 R1010 BEA 16/116 1SBN 081 406 R1000 A 9-30-10 48V-50Hz 1SBL 141 001 R8310 VE 5-1 1SBN 030 110 R1000 BEY 16V-1 1SBN 081 413 R1001 BER 16V 1SBN 081 411 R1000 TA 25 DU 19 1SAZ 211 201 R1047 Star-Delta Starters Tables for ordering details, pages 37, 39 Reversing Starters Tables for ordering details, pages 18 ... 21 0/2 1SBC141158C0201 Motor Starting Solutions Protection by Manual Motor Starter Rated Power - 400 V AC-3 Direct-On-Line Starters Reversing Starters 0.06 kW ... 51 kW 0.06 kW ... 51 kW MS 116 ... MS 495 MS 116 ... MS 495 a.c. Operated Contactors A 9 ... A 110 a.c. Operated Contactors A 9 ... A 110 Connection Links BEA 16/.. ... BEA 110/495 BEA 16/.. ... BEA 110/495 Connection Sets – BER 16.. ... BEM 110/30 Manual Motor Starters Contactors Protection by Thermal Overload Relay Rated Power - 400 V AC-3 Contactors Thermal Overload Relays Connection Sets 2 1SBC101001C0201 Direct-On-Line Starters Reversing Starters 4 kW ... 55 kW 4 kW ... 55 kW a.c. Operated Contactors A 9 ... A 110 a.c. Operated Contactors A 9 ... A 110 TA 25 DU ... TA 110 DU TA 25 DU ... TA 110 DU – BER 16.. ... BEM 110/30 Open Type Version in Kit Form Direct-On-Line and Reversing Starters with Smissline System Rated Power - 400 V AC-3 Manual Motor Starters Contactors 0.06 kW ... 11 kW MS 116 ... MS 325 a.c. Operated Contactors A 9 ... A 26 Connection Accessories BEA 16/.. ... BEA 26/.., BER 16.. ... BER 40.. Smissline Components Combi-modul and Accessories Star-Delta Starters Rated Power - 400 V AC-3 Contactors 7.5 kW ... 90 kW a.c. Operated Contactors A 9 ... A 110 Thermal Overload Relays TA 25 DU ... TA 110 DU Connection Sets BEY 16 ... BED 110 3 1SBC101001C0201 General Information Direct-On-Line Starting of Three-Phase Asynchonous Motors General A combination starter performs the following functions: ● circuit isolation and short-circuit protection, ● motor "ON" - "OFF" control, ● overload protection. The isolation and short-circuit protection functions must be performed by a fuse isolator switch, a fuse switch or a circuit-breaker. Fuse ratings recommended in the coordination tables should be used. (A complete data base of coordination tables is available on the ABB Website.) The «ON» - «OFF» control and overload protection functions are performed by a contactor and thermal overload relay combination. Full voltage Direct-On-Line starting is a simple, economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current. I /I n C /C n 7 I = current; In C = torque; Cn = nominal torque = nominal current 6 I 5 4 3 2 C Nominal values A1011DG 1 0 10 4 1SBC101001C0201 30 60 80 100 Motor speed (%) General Information Star-Delta Starting of Three-Phase Asynchonous Motors General Star-delta starting is the most common method to reduce the starting current of a motor. This system can be used on all the squirrel cage motors, which are normally used in delta connection. In this type of starting, it is recommended to choose motors having high starting torque i.e. much higher than the resistive torque in order to reach sufficient high speed when the motor is connected in star. Star-Delta Starting I /I n T /T n 7 I = current; In T = torque; Tn = nominal torque Technical Data = nominal current When starting: – inrush current is reduced to a third of direct starting current, – motor torque is reduced to a third or even less of direct starting torque. 6 I (delta) Transient current is generated when switching from star to delta connection. 5 Utilization 4 3 T 2 ( m ot or ) I (sta r) E0899DG 1 T (motor) Tr (resistive torque) 0 20 40 60 80 During the initial starting phase («star» connection), the resistive torque of the driven load must remain, irrespective of speed, less than the «star» motor torque until «star-delta» switching occurs. This starting mode is therefore ideal for machines having low starting torque such as: – pumps, – centrifugal compressors, – wood-working machines, etc. In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching from star to delta. 100 Motor speed (%) Precautions Motor nominal voltage in delta connection must be equal to that of the mains. Example: A motor for 400 V star-delta starting must be designed for 400 V in «delta» connection. Its usual designation is «400 V / 690 V motor». The motor must be constructed with 6 terminal windings. Sequence Starting is a three-stage process: 1st stage - «Star» connection - Press the «On» button on the control circuit to close the KM2 «star» contactor. The KM1 «line» contactor then closes and the motor starts. Countdown of programmed starting time (normally 6 to 10 s) then begins. 2nd stage - «Star» to «Delta» switching - When the programmed starting time is over, the KM2 «star» contactor opens. 3rd stage - «Delta» connection - A transition time (or dwelling time) of 50 ms is fixed between opening of the «star» contactor and closing of the «delta» contactor by the use of TE5S timer. This prevents short circuit between «star» and «delta». (Switching frequency/hour, according to acceleration time and load factor). Respect of the following conditions enables utilization of the starter without excessive overheating of the connections or nuisance tripping of the thermal O/L relay. Example: – Switching frequency = 15 starts/hr – Acceleration time "ta" = 7s (use 8 s curve) – Maximum load factor = 50 % This corresponds to a 4-minute operating cycle 2 minutes operation and 2 minutes rest. 55 50 30 20 15 (15 starts/hr) with 7 seconds acceleration, ta 40 10 0 = 5 s. ta = 8s . ta = 10 s . ta = 12 s . ta = 1 5 ta = 2 s. 0 s. 20 E1142DG Maximum duty as per the chart on side. Number of starts / hour Note: When AF... contactor types are used as delta and star contactors or an A... contactor as star contactor with an AF... contactor as delta contactor, the use of a timer including a dwelling time (or transition time) e.g. TE5S is not recommended. A timer set for the starting duration in star connection is enough. An electrical interlock between star and delta is mandatory such as VE 5 or through auxiliary contacts. Furthermore, in open transition, the current interruption may reach up to 95 ms: it shall be checked that this duration is compatible with the application i.e. mainly if the decreasing in rotation speed is acceptable during the starting phase. 40 50 60 80 100 Load factor (%) 5 1SBC101001C0201 General Information Motor Rated Operational Powers and Currents The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz. 1800 r.p.m. at 60 Hz). These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles. Motor nominal current: standardized values in red colour (according to IEC 60947-4-1 Annex G) UL / CSA Motor nominal current: standardized values (according to IEC 60947-4-1 Annex G and UL 508) Motor power kW 220 V 230 V 240 V 380V A A A A 400 V 415 V 440 V 500 V 660 V 690 V A A A A A A Motor power hp 208 V A 220-240 V A 380-415 V A 440-480 V A 550-600 V A 0.06 0.37 0.35 0.34 0.21 0.2 0.19 0.18 0.16 0.13 0.12 1/2 2.4 2.2 1.3 1.1 0.9 0.09 0.54 0.52 0.50 0.32 0.3 0.29 0.26 0.24 0.18 0.17 3/4 3.5 3.2 1.8 1.6 1.3 0.12 0.73 0.7 0.67 0.46 0.44 0.42 0.39 0.32 0.24 0.23 1 4.6 4.2 2.3 2.1 1.7 0.18 1 1 1 0.63 0.6 0.58 0.53 0.48 0.37 0.35 1-1/2 6.6 6 3.3 3 2.4 0.25 1.6 1.5 1.4 0.9 0.85 0.82 0.74 0.68 0.51 0.49 2 7.5 6.8 4.3 3.4 2.7 0.37 2.0 1.9 1.8 1.2 1.1 1.1 1.0 0.88 0.67 0.64 3 10.6 9.6 6.1 4.8 3.9 0.55 2.7 2.6 2.5 1.6 1.5 1.4 1.3 1.2 0.91 0.87 5 16.7 15.2 9.7 7.6 6.1 0.75 3.5 3.3 3.2 2.0 1.9 1.8 1.7 1.5 1.15 1.1 7-1/2 24.2 22 14 11 9 1.1 4.9 4.7 4.5 2.8 2.7 2.6 2.4 2.2 1.7 1.6 10 30.8 28 18 14 11 1.5 6.6 6.3 6.0 3.8 3.6 3.5 3.2 2.9 2.2 2.1 15 46.2 42 27 21 17 2.2 8.9 8.5 8.1 5.2 4.9 4.7 4.3 3.9 2.9 2.8 20 59.4 54 34 27 22 3 11.8 11.3 10.8 6.8 6.5 6.3 5.7 5.2 4.0 3.8 25 74.8 68 44 34 27 4 15.7 15 14.4 8.9 8.5 8.2 7.4 6.8 5.1 4.9 30 88 80 51 40 32 5.5 20.9 20 19.2 12.1 11.5 11.1 10.1 9.2 7.0 6.7 40 114 104 66 52 41 7.5 28.2 27 25.9 16.3 15.5 14.9 13.6 12.4 9.3 8.9 50 143 130 83 65 52 11 39.7 38 36.4 23.2 22 21.2 19.3 17.6 13.4 12.8 60 169 154 103 77 62 15 53.3 51 48.9 30.5 29 28.0 25.4 23 17.8 17 75 211 192 128 96 77 18.5 63.8 61 58.5 36.8 35 33.7 30.7 28 22.0 21 100 273 248 165 124 99 22 75.3 72 69 43.2 41 39.5 35.9 33 25.1 24 125 343 312 208 156 125 30 100 96 92 57.9 55 53 48.2 44 33.5 32 150 396 360 240 180 144 37 120 115 110 69 66 64 58 53 40.8 39 200 528 480 320 240 192 45 146 140 134 84 80 77 70 64 49.1 47 250 – 604 403 302 242 55 177 169 162 102 97 93 85 78 59.6 57 300 – 722 482 361 289 75 240 230 220 139 132 127 116 106 81 77 350 – 828 560 414 336 90 291 278 266 168 160 154 140 128 97 93 400 – 954 636 477 382 110 355 340 326 205 195 188 171 156 118 113 450 – 1030 – 515 412 132 418 400 383 242 230 222 202 184 140 134 500 – 1180 786 590 472 160 509 487 467 295 280 270 245 224 169 162 200 637 609 584 368 350 337 307 280 212 203 250 782 748 717 453 430 414 377 344 261 250 315 983 940 901 568 540 520 473 432 327 313 355 1109 1061 1017 642 610 588 535 488 370 354 400 1255 1200 1150 726 690 665 605 552 418 400 500 1545 1478 1416 895 850 819 745 680 515 493 560 1727 1652 1583 1000 950 916 832 760 576 551 630 1928 1844 1767 1116 1060 1022 929 848 643 615 710 2164 2070 1984 1253 1190 1147 1043 952 721 690 800 2446 2340 2243 1417 1346 1297 1179 1076 815 780 900 2760 2640 2530 1598 1518 1463 1330 1214 920 880 1000 3042 2910 2789 1761 1673 1613 1466 1339 1014 970 IEC 6 1SBC101001C0201 General Information Utilization Categories I (A) I (A) AC-3 AC-1 Id In In Starting t (s) E0517DF t (s) Id E0515D Utilization categories AC-4 Inching t (s) E0517DF I (A) A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated. Utilization categories for contactors according to IEC 60947-4-1: Alternating current AC-1 Non-inductive or slightly inductive loads, resistance furnaces. AC-2 Slip-ring motors: starting, switching off. AC-3 Cage motors: starting, switching off running motors. AC-4 Cage motors: starting, plugging, inching. Making and Breaking Conditions for Utilization Categories Utilization category Durability test conditions Making conditions Occasional operation Making and Breaking Capacities - 50 operating cycles Breaking conditions I/Ie U/Ue Cos. φ or L/R (ms) I/Ie U/Ue AC-1 1 1 0.95 1 AC-2 2.5 1 0.65 2.5 Making conditions Breaking conditions Cos. φ or L/R (ms) Ic /Ie Ur/Ue Cos. φ or L/R (ms) Ic/Ie Ur/Ue Cos. φ or L/R (ms) 1 0.95 1.5 1.05 0.8 1.5 1.05 0.8 1 0.65 4 1.05 0.65 4 1.05 0.65 AC-3 Ie < 17 A 17 < Ie < 100 A Ie > 100 A 6 6 6 1 1 1 0.65 0.35 0.35 1 1 1 0.17 0.17 0.17 0.65 0.35 0.35 10 10 10 1.05 1.05 1.05 0.45 0.45 0.35 8 8 8 1.05 1.05 1.05 0.45 0.45 0.35 AC-4 Ie < 17 A 17 < Ie < 100 A Ie > 100 A 6 6 6 1 1 1 0.65 0.35 0.35 6 6 6 1 1 1 0.65 0.35 0.35 12 12 12 1.05 1.05 1.05 0.45 0.45 0.35 10 10 10 1.05 1.05 1.05 0.45 0.45 0.35 Key: U (I) Ur L/R Ue (Ie) Ic = applied voltage (current) = recovery voltage = test circuit time constant = rated operational voltage (current) = making and breaking current expressed in d.c. or in a.c. like the r.m.s. value of the symmetrical components 7 1SBC101001C0201 General Information Coordination with Short-circuit Protection Devices In compliance with standards IEC 60947-4-1 and EN 60947-4-1, we define for the contactors and starters the type, rating and characteristics of the short-circuit protection devices SCPD which allow selective protection against overloads and ensure protection against short circuits. Basic Functions Any starter is designed to: – start motors, – ensure continuous functioning of motors, – disconnect motors from the supply line, – guarantee protection of motors against overloads. The starter is typically made up of a switching device (contactor) and an overload protection device (thermal overload relay TOR or electronic overload relay EOR). These two devices MUST be coordinated with equipment capable of providing protection against short circuit (SCPD: short-circuit protective device): typically a circuit breaker with magnetic release only or a switch fuse. These are not necessarily part of the starter. Applicable Standards IEC 60947-4-1 (EN 60947-4-1) precisely defines the different points to be considered in order to carry out correct coordination. Complete coordination for a combination includes the following points: – Selectivity test between the overload relay and the short-circuit protection device SCPD. – Short-circuit condition tests: ● at prospective "r" currents - These currents depend on the rated operational current of the starter (Ie AC-3) and are given by the standard (Table 11). For example: r = 1kA for Ie AC-3 < 16 A r = 3 kA for 16 A < Ie AC-3 < 63 A r = 5 kA for 63 A < Ie AC-3 < 125 A etc. ● at the rated prospective short-circuit current "Iq" - This is the maximum current that the combination can withstand, for example 50 kA. Types of Coordination IEC 60947-4-1 (EN 60947-4-1) defines two types of coordination according to the expected level of service continuity. Acceptable extreme damage for the switchgear is divided into two types. Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate without being repaired or having parts replaced. Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards. The risk of contacts light welding is acceptable. The Complete ABB Offer ABB has acquired years of experience with respect to problems of coordination and is able to make a complete offer based on tests performed in its qualified laboratories. This offer includes 400 V, 500 V, 690 V networks. A complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1), is available on the ABB Website. In the coordination tables, the following short-circuit protection devices are recommended: Moulded case circuit-breakers (MCCBs) Miniature circuit-breakers (MCBs) ● Switch-disconnector-fuses (aM, gG and BS) ● Manual Motor Starters (M.M.S.) ● ● General Remarks Applicable to all Tables Each table is defined for a maximum ambient temperature of 40 °C. For higher temperatures, apply a derating factor according to the following rules: ● – Fuses: factor of 0.8 applied to In for an ambient temperature of 70 °C. – MCCBs and MCBs: factor of 0.8 applied to In for an ambient temperature of 60 °C. – The starter derating factor depends on the operating conditions of thermal overload relays: Factor of 0.9 applied to In for an ambient temperature of 70 °C. ● Each table is defined for motor currents: 3-phase motors, 4-pole. ● Normal starting means a starting time < 2 s. - Difficult starting means an accelerating time 10 s < ts < 30 s. Tripping classes of thermal O/L relays according to IEC 60947-4-1 (EN 60947-4-1): 10 A and 10 for DU types and 30 for SU types. ● In the tables with MCCBs, these are fitted with the magnetic relay alone. Setting is always carried out at > 12.3 Ie AC-3 so that the transient current peak occurring during starting does not lead to tripping. 8 1SBC101001C0201 General Information Coordination with Short-circuit Protection Devices A motor starter is typically made up of a switching device (contactor) and an overload protection device (see opposite page "Basic Functions"). These two devices MUST be coordinated with an equipment capable of providing protection against short-circuit (SCPD: Short-Circuit Protection Device). A complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1), is available on the ABB Website: see www.abb.com/lowvoltage then go to the right menu: "Support", select: "Online Product Selection Tools". Online Selected Optimized Coordination Tables Introduction Instructions F.A.Q. Troubleshooting Short-Circuit Protection Device (SCPD) selection Selection Switch-disconnector-fuses (aM and gG) Miniature Circuit-Breakers (MCBs) Moulded Case Circuit-Breakers (MCCBs) Manual Motor Starters (MMS) Complete coordination tables are available for the Short-Circuit Protection Device (SCPD), the Contactor and the Overload Protection Device according to the Rated Operational Voltage Ue, the Rated Short-circuit Current Iq, the Coordination Type (type 1 or 2) and the Motor Power. www.abb.com/lowvoltage Online Selected Optimized Coordination Tables 9 1SBC101001C0201 Direct-On-Line Starters Open Type Version, in Kit Form I> Protected by Manual Motor Starter MS... MS... BEA... BEA... A9 ... A26 A30 ... A110 Selection Table Manual motor starters MS 116 MS 325 MS 450 MS 495 3-pole a.c. operated contactors A9 A12 A16 A26 A9 A12 A16 A26 A30 BEA 26/116 BEA 16/325 BEA 26/325 PM 26-13 Not required PM 26-13 A40 A30 A40 A50 A63 A75 BEA 50/450 BEA 75/495 A95 A110 Connecting links BEA 16/116 Mounting plate Not required 10 1SBC101001C0201 BEA 40/450 BEA 110/495 Direct-On-Line Starters Open Type Version, in Kit Form I> Protected by Manual Motor Starter Application Direct-on-line starters for controlling three-phase asynchronous motors: – up to an operational voltage of 415V - 50 or 60 Hz – for a starting time of 1.5 s max. and a switching frequency of < 15 starts an hour with a load factor of 80% < 30 starts an hour with a load factor of 50% – with an ambient temperature near the devices < 50°C – type 1 or type 2 coordination, complying with IEC 60947-4-1 / EN 60947-4-1 1SBC5 8294 5F0301 Coordination MS 116 + BEA 16/116 + A 9-30-10 In the event of a short-circuit, the starter is subjected to thermal stresses, in addition to very high electrodynamic stresses, proportional to short-current time. The capacity to withstand these high stresses depands upon the perfect coordination of the devices which make up the starter. The contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 defining the anticipated level of service continuity (Standard EN 60947-4-1 / IEC 60947-4-1). The tables overleaf show, for each of the two coordination types, the most usual combination between the MS… manual motor starters and the contactors, according to AC-3 currents and motor powers for: – coordination type 1 and type 2 at 400 V, 50 / 60 Hz, Iq = 16 kA – coordination type 1 and type 2 at 400 V, 50 / 60 Hz, Iq = 50 kA. Mounting and Connection Accessory Description The BEA.. insulated 3-pole connecting link (touch safe) is used to electrically and mechanically connect the MS.. manual motor starter and the A... serie contactor. This accessory eliminates the potential risk of wiring errors, reduces the time required to install, to test and to maintain a Direct-On-Line starter. The PM26-13 mounting plate facilitates: - the mounting and the dismounting of a A 26-30-.. up to A 40-30-.. contactor and its associated manual motor starter with the use of a BEA26/.. connecting link - the simple snap fitting of the starter onto standard 35 mm rails within the control panel, or screw fitting onto the mounting plate. 11 1SBC101001C0201 Direct-On-Line Starters Protected by Manual Motor Starter I> Coordination Type 1 Ordering Details - Coordination type 1, 400 V, 16 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.48 4 8.6 5.5 7.5 11.1 14.8 Contactor Accessories Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 0.16 - 0.25 1SAM 250 000 R1002 3 A9-30-10 1SBL 141 001 R 10 MS116-0.40 0.25 - 0.40 1SAM 250 000 R1003 4.8 A9-30-10 1SBL 141 001 R 10 MS116-0.63 0.40 - 0.63 1SAM 250 000 R1004 7.56 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-2.50 1.60 - 2.50 1SAM 250 000 R1007 30 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A9-30-10 1SBL 141 001 R 10 MS116-6.30 4.00 - 6.30 1SAM 250 000 R1009 75.6 A9-30-10 1SBL 141 001 R 10 MS116-10.0 6.30 - 10.0 1SAM 250 000 R1010 120 A12-30-10 1SBL 161 001 R 10 MS116-10.0 6.30 - 10.0 1SAM 250 000 R1010 120 A12-30-10 1SBL 161 001 R 10 MS116-12.0 8.00 - 12.0 1SAM 250 000 R1012 144 A12-30-10 1SBL 161 001 R 10 MS116-16.0 10.0 - 16.0 1SAM 250 000 R1011 192 A16-30-10 1SBL 181 001 R 10 Unit piece Current setting range A state coil voltage code Unit piece Allowed Setting current A Type Connecting link between MS.. and contactor Fixing 0.25 BEA 16/116 on rail (1) 0.4 BEA 16/116 on rail (1) 0.63 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 2.5 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 6.3 BEA 16/116 on rail (1) 10 BEA 16/116 on rail (1) 10 BEA 16/116 on rail (1) 12 BEA 16/116 on rail (1) 16 BEA 16/116 on rail (1) (1) No mounting plate required. MS.. can be fitted directly on a 35 mm rail. Ordering Details - Main Accessories Description Connecting links Mounting plate Type Order Code Packing pieces Weight kg BEA 16/116 1SBN 081 406 R1000 10 0.020 BEA 16/325 1SBN 081 406 R1001 10 0.031 BEA 26/325 1SBN 082 406 R1001 10 0.031 BEA 40/450 1SBN 083 206 R1000 1 0.061 BEA 50/450 1SBN 083 506 R1000 1 0.062 BEA 75/495 1SBN 084 106 R1000 1 0.120 BEA 110/495 1SBN 084 506 R1000 1 0.124 PM 26-13 1SBN 092 406 R1000 2 0.160 >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 12 1SBC101001C0201 Direct-On-Line Starters Protected by Manual Motor Starter I> Coordination Type 1 Ordering Details - Coordination type 1, 400 V, 50 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.6 4 8.5 5.5 7.5 9 11.5 15.5 18.3 11 15 18.5 22 30 37 45 51 22 30 37 44 60 72 85 94 Contactor Accessories Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 0.16 - 0.25 1SAM 250 000 R1002 3 A9-30-10 1SBL 141 001 R 10 MS116-0.40 0.25 - 0.40 1SAM 250 000 R1003 4.8 A9-30-10 1SBL 141 001 R 10 MS116-0.63 0.40 - 0.63 1SAM 250 000 R1004 7.56 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-2.50 1.60 - 2.50 1SAM 250 000 R1007 30 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A9-30-10 1SBL 141 001 R 10 MS116-6.30 4.00 - 6.30 1SAM 250 000 R1009 75.6 A9-30-10 1SBL 141 001 R 10 MS325-9.00 6.30 - 9.00 1SAM 150 000 R1010 135 A9-30-10 1SBL 141 001 R 10 MS325-9.00 6.30 - 9.00 1SAM 150 000 R1010 135 A9-30-10 1SBL 141 001 R 10 MS325-12.5 9.00 - 12.5 1SAM 150 000 R1011 187.5 A12-30-10 1SBL 161 001 R 10 MS325-16.0 12.5 - 16.0 1SAM 150 000 R1012 240 A16-30-10 1SBL 181 001 R 10 MS325-20.0 16.0 - 20.0 1SAM 150 000 R1013 300 A26-30-10 1SBL 241 001 R 10 MS325-25.0 20.0 - 25.0 1SAM 150 000 R1014 375 A26-30-10 1SBL 241 001 R 10 MS450-32.0 22.0 - 32.0 1SAM 450 000 R1004 384 A30-30-10 1SBL 281 001 R 10 MS450-40.0 28.0 - 40.0 1SAM 450 000 R1005 480 A40-30-10 1SBL 321 001 R 10 MS450-50.0 40.0 - 50.0 1SAM 450 000 R1007 600 A50-30-00 1SBL 351 001 R 00 MS495-63.0 45.0 - 63.0 1SAM 550 000 R1007 756 A63-30-00 1SBL 371 001 R 00 MS495-75.0 57.0 - 75.0 1SAM 550 000 R1008 900 A75-30-00 1SBL 411 001 R 00 MS495-90.0 70.0 - 90.0 1SAM 550 000 R1009 1080 A95-30-00 1SFL 431 001 R 00 MS495-100 80.0 - 100 1SAM 550 000 R1010 1200 A95-30-00 1SFL 431 001 R 00 Unit piece Current setting range A state coil voltage code Unit piece Allowed Setting current A Type Connecting link between MS.. and contactor Fixing 0.25 BEA 16/116 on rail (1) 0.4 BEA 16/116 on rail (1) 0.63 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 2.5 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 6.3 BEA 16/116 on rail (1) 9 BEA 16/325 on rail (1) 9 BEA 16/325 on rail (1) 12 BEA 16/325 on rail (1) 16 BEA 16/325 on rail (1) 20 BEA 26/325 PM 26-13 25 BEA 26/325 PM 26-13 30 BEA 40/450 - 38 BEA 40/450 - 47.5 BEA 50/450 - 60 BEA 75/495 - 72.5 BEA 75/495 - 85 BEA 110/495 - 96 BEA 110/495 - (1) No mounting plate required. MS.. can be fitted directly on a 35 mm rail. >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 13 1SBC101001C0201 Direct-On-Line Starters Protected by Manual Motor Starter I> Coordination Type 2 Ordering Details - Coordination type 2, 400 V, 16 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.48 4 8.6 5.5 7.5 11.1 14.8 Contactor Accessories Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 0.16 - 0.25 1SAM 250 000 R1002 3 A9-30-10 1SBL 141 001 R 10 MS116-0.40 0.25 - 0.40 1SAM 250 000 R1003 4.8 A9-30-10 1SBL 141 001 R 10 MS116-0.63 0.40 - 0.63 1SAM 250 000 R1004 7.56 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-2.50 1.60 - 2.50 1SAM 250 000 R1007 30 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A16-30-10 1SBL 181 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A16-30-10 1SBL 181 001 R 10 MS116-6.30 4.00 - 6.30 1SAM 250 000 R1009 75.6 A16-30-10 1SBL 181 001 R 10 MS116-10.0 6.30 - 10.0 1SAM 250 000 R1010 120 A26-30-10 1SBL 241 001 R 10 MS116-10.0 6.30 - 10.0 1SAM 250 000 R1010 120 A26-30-10 1SBL 241 001 R 10 MS116-12.0 8.00 - 12.0 1SAM 250 000 R1012 144 A26-30-10 1SBL 241 001 R 10 MS116-16.0 10.0 - 16.0 1SAM 250 000 R1011 192 A26-30-10 1SBL 241 001 R 10 Unit piece Current setting range A state coil voltage code Unit piece Allowed Setting current A Type Connecting link between MS.. and contactor Fixing 0.25 BEA 16/116 on rail (1) 0.4 BEA 16/116 on rail (1) 0.63 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 2.5 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 6.3 BEA 16/116 on rail (1) 10 BEA 26/116 PM 26-13 10 BEA 26/116 PM 26-13 12 BEA 26/116 PM 26-13 16 BEA 26/116 PM 26-13 (1) No mounting plate required. MS.. can be fitted directly on a 35 mm rail. Ordering Details - Main Accessories Description Connecting links Mounting plate Type Order Code Packing pieces Weight kg BEA 16/116 1SBN 081 406 R1000 10 0.020 BEA 26/116 1SBN 082 406 R1000 10 0.024 BEA 26/325 1SBN 082 406 R1001 10 0.031 BEA 40/450 1SBN 083 206 R1000 1 0.061 BEA 50/450 1SBN 083 506 R1000 1 0.062 BEA 75/495 1SBN 084 106 R1000 1 0.120 BEA 110/495 1SBN 084 506 R1000 1 0.124 PM 26-13 1SBN 092 406 R1000 2 0.160 >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 14 1SBC101001C0201 Direct-On-Line Starters Protected by Manual Motor Starter I> Coordination Type 2 Ordering Details - Coordination type 2, 400 V, 50 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.6 4 8.5 5.5 7.5 9 11.5 15.5 18.3 11 15 18.5 22 30 37 45 51 22 30 37 44 60 72 85 94 Contactor Accessories Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 0.16 - 0.25 1SAM 250 000 R1002 3 A9-30-10 1SBL 141 001 R 10 MS116-0.40 0.25 - 0.40 1SAM 250 000 R1003 4.8 A9-30-10 1SBL 141 001 R 10 MS116-0.63 0.40 - 0.63 1SAM 250 000 R1004 7.56 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.00 0.63 - 1.00 1SAM 250 000 R1005 12 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-1.60 1.00 - 1.60 1SAM 250 000 R1006 19.2 A9-30-10 1SBL 141 001 R 10 MS116-2.50 1.60 - 2.50 1SAM 250 000 R1007 30 A9-30-10 1SBL 141 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A16-30-10 1SBL 181 001 R 10 MS116-4.00 2.50 - 4.00 1SAM 250 000 R1008 48 A16-30-10 1SBL 181 001 R 10 MS116-6.30 4.00 - 6.30 1SAM 250 000 R1009 75.6 A16-30-10 1SBL 181 001 R 10 MS325-9.00 6.30 - 9.00 1SAM 150 000 R1010 135 A26-30-10 1SBL 241 001 R 10 MS325-9.00 6.30 - 9.00 1SAM 150 000 R1010 135 A26-30-10 1SBL 241 001 R 10 MS325-12.5 9.00 - 12.5 1SAM 150 000 R1011 187.5 A26-30-10 1SBL 241 001 R 10 MS325-16.0 12.5 - 16.0 1SAM 150 000 R1012 240 A26-30-10 1SBL 241 001 R 10 MS325-20.0 16.0 - 20.0 1SAM 150 000 R1013 300 A26-30-10 1SBL 241 001 R 10 MS325-25.0 20.0 - 25.0 1SAM 150 000 R1014 375 A30-30-10 1SBL 281 001 R 10 MS450-32.0 22.0 - 32.0 1SAM 450 000 R1004 384 A40-30-10 1SBL 321 001 R 10 MS450-40.0 28.0 - 40.0 1SAM 450 000 R1005 480 A40-30-10 1SBL 321 001 R 10 MS450-50.0 40.0 - 50.0 1SAM 450 000 R1007 600 A63-30-00 1SBL 371 001 R 00 MS495-63.0 45.0 - 63.0 1SAM 550 000 R1007 756 A75-30-00 1SBL 411 001 R 00 MS495-75.0 57.0 - 75.0 1SAM 550 000 R1008 900 A75-30-00 1SBL 411 001 R 00 MS495-90.0 70.0 - 90.0 1SAM 550 000 R1009 1080 A95-30-00 1SFL 431 001 R 00 MS495-100 80.0 - 100 1SAM 550 000 R1010 1200 A95-30-00 1SFL 431 001 R 00 Unit piece Current setting range A state coil voltage code Unit piece Allowed Setting current A Type Connecting link between MS.. and contactor Fixing 0.25 BEA 16/116 on rail (1) 0.4 BEA 16/116 on rail (1) 0.63 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 1.6 BEA 16/116 on rail (1) 2.5 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 4 BEA 16/116 on rail (1) 6.3 BEA 16/116 on rail (1) 9 BEA 26/325 PM-26-13 9 BEA 26/325 PM 26-13 12.5 BEA 26/325 PM 26-13 16 BEA 26/325 PM 26-13 20 BEA 26/325 PM 26-13 25 BEA 26/325 PM 26-13 30 BEA 40/450 - 38 BEA 40/450 - 47.5 BEA 50/450 - 60 BEA 75/495 - 72.5 BEA 75/495 - 85 BEA 110/495 - 96 BEA 110/495 - (1) No mounting plate required. MS.. can be fitted directly on a 35 mm rail. >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 15 1SBC101001C0201 Reversing Starters Open Type Version, in Kit Form I> Protected by Manual Motor Starter MS.. PM 26-23 MS.. BEA.. BEA.. BER, BEM VM 5-1, VE 5-1 VE 5-.. A9 ... A26 A9 ... A26 A30 ... A110 A30 ... A110 BER .. Selection Table Manual motor starters MS 116 MS 325 MS 450 MS 495 3-pole a.c. operated contactors A9 A12 A16 A26 A9 BEA 26/116 BER 40V (1) A12 A16 A26 A30 A40 BEA 16/325 BEA 26/325 BEA 40/450 BER 16V (1) BER 40V (1) A50 A63 A75 BEA 50/450 BEA 75/495 A95 A110 Connecting links BEA 16/116 BEA 110/495 Connection sets BER 16V (1) BEM 75-30 (1) If only an electrical interlocking is required between contactors A 9 up to A 40, use BER 16 and BER 40 connection sets for contactors with N.C. built-in auxiliary contacts to reduce the space between contactors. Mounting plate PM 26-23 Mechanical /electrical interlock units VM 5-1 / VE 5-1 16 1SBC101001C0201 BEM 110-30 VE 5-2 Reversing Starters Open Type Version, in Kit Form I> Protected by Manual Motor Starter Application Reversing starters for controlling three-phase asynchronous motors: – up to an operational voltage of 415 V - 50 or 60 Hz – for a starting time of 1.5 s max. and a switching frequency of < 15 starts an hour with a load factor of 80 % of < 30 starts an hour with a load factor of 50 % – with an ambient temperature near the devices < 50 °C – type 1 or type 2 coordination, complying with IEC 60947-4-1 / EN 60947-4-1 1SBC5 9292 5F0302 Coordination MS 116 + 2 x A 9-30-10 + BEA 16/116 + VE 5-1 + BER 16V + PM 26-23 In the event of a short-circuit, the starter is subjected to thermal stresses, in addition to very high electrodynamic stresses, proportional to short-current time. The capacity to withstand these high stresses depands upon the perfect coordination of the devices which make up the starter. Standard EN 60947-4-1/IEC 60947-4-1 defines the two types of coordination according to the anticipated level of service continuity. The tables overleaf show, for each of the two coordination types, the most usual combination between the MS… manual motor starters and the contactors, according to AC-3 currents and motor powers for: – coordination type 1 and type 2 at 400 V, 50 / 60 Hz, Iq = 16 kA – coordination type 1 and type 2 at 400 V, 50 / 60 Hz, Iq = 50 kA. Mounting and Connection Accessory Description The BEA connecting links, the VE 5-... or VM 5-1 interlock unit, the BER or BEM connection sets and the PM 26-23 mounting plate allow to realize reversing starters, including A... serie contactors and MS... manual motor starter controlling and protecting motors against overloads and short-circuits according to coordination types 1 and 2. These accessories eliminate the potential risk of wiring errors, reduce the time required to install, to test and to maintain a reversing starter. The BEA insulated 3-pole connecting link (touch safe) is used to electrically and mechanically connect the MS.. manual motor starter and the A... serie contactor. The BER / BEM connection set is used to do a safe and simple connection between both contactor main terminals. The interlocking function can be easily assured by a simple mounting of : – a VE 5-.. unit between both contactors for a mechanical and electrical interlocking – a VM 5-1 unit between both contactors for a mechanical interlocking and add-on N.C. auxiliary contacts for the electrical interlocking (or use contactors with built-in N.C. auxiliary contacts). Note: if only an electrical interlocking is required between contactors A 9 up to A 40, use BER 16 and BER 40 connection sets and contactors with built-in N.C. auxiliary contacts (A 9-30-01 ... A 40-30-01 contactors, see main catalogue). The PM 26-23 mounting plate facilitates: – the mounting and dismounting of the contactors and the manual motor starter – the simple snap fitting of the reversing starter onto standard 35 mm rails within the control panel, or screw fitting onto the mounting plate. 17 1SBC101001C0201 Reversing Starters Protected by Manual Motor Starter I> Coordination Type 1 Ordering Details - Coordination type 1, 400 V, 16 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.48 4 8.6 5.5 7.5 11.1 14.8 Contactor Accessories Current setting range A Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 1SAM 250 000 R1002 0.16 - 0.25 3 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.40 1SAM 250 000 R1003 0.25 - 0.40 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.63 1SAM 250 000 R1004 0.40 - 0.63 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-2.50 1SAM 250 000 R1007 1.60 - 2.50 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-6.30 1SAM 250 000 R1009 4.00 - 6.30 2 x A9-30-10 1SBL 141 001 R 10 MS116-10.0 1SAM 250 000 R1010 6.30 - 10.0 2 x A12-30-10 1SBL 161 001 R 10 MS116-10.0 1SAM 250 000 R1010 6.30 - 10.0 2 x A12-30-10 1SBL 161 001 R 10 MS116-12.0 1SAM 250 000 R1012 8.00 - 12.0 2 x A12-30-10 1SBL 161 001 R 10 MS116-16.0 1SAM 250 000 R1011 10.0 - 16.0 2 x A16-30-10 1SBL 181 001 R 10 Unit piece 4.8 7.56 12 12 19.2 19.2 30 48 48 75.6 120 120 144 192 state coil voltage code Unit piece Allowed Setting current A Connecting link between MS.. and contactors Interlock unit Connection Mounting set for the plate contactors 0.25 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.4 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.63 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 2.5 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 6.3 BEA 16/116 VE 5-1 BER 16V PM 26-23 10 BEA 16/116 VE 5-1 BER 16V PM 26-23 10 BEA 16/116 VE 5-1 BER 16V PM 26-23 12 BEA 16/116 VE 5-1 BER 16V PM 26-23 16 BEA 16/116 VE 5-1 BER 16V PM 26-23 Packing pieces Weight kg Ordering Details - Main Accessories Description Connecting links Mechanical interlock unit Mechanical & electrical interlock units Connection sets Mounting plate Type Order Code BEA 16/116 1SBN 081 406 R1000 10 0.020 BEA 16/325 1SBN 081 406 R1001 10 0.031 BEA 26/325 1SBN 082 406 R1001 10 0.031 BEA 40/450 1SBN 083 206 R1000 1 0.061 BEA 50/450 1SBN 083 506 R1000 1 0.062 BEA 75/495 1SBN 084 106 R1000 1 0.120 BEA 110/495 1SBN 084 506 R1000 1 0.124 VM 5-1 1SBN 030 100 R1000 1 0.066 VE 5-1 1SBN 030 110 R1000 1 0.076 VE 5-2 1SBN 030 210 R1000 1 0.146 BER 16V 1SBN 081 411 R1000 1 0.045 BER 40V 1SBN 082 411 R1000 1 0.085 BEM 75-30 1SBN 083 501 R1000 1 0.243 BEM 110-30 1SFN 084 301 R1000 1 0.450 PM 26-23 1SBN 091 407 R1000 1 0.330 >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 18 1SBC101001C0201 Reversing Starters Protected by Manual Motor Starter I> Coordination Type 1 Ordering Details - Coordination type 1, 400 V, 50 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.6 4 8.5 5.5 7.5 9 11.5 15.5 18.3 11 15 18.5 22 30 37 45 51 22 30 37 44 60 72 85 94 Contactor Accessories Current setting range A Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 1SAM 250 000 R1002 0.16 - 0.25 3 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.40 1SAM 250 000 R1003 0.25 - 0.40 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.63 1SAM 250 000 R1004 0.40 - 0.63 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-2.50 1SAM 250 000 R1007 1.60 - 2.50 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-6.30 1SAM 250 000 R1009 4.00 - 6.30 2 x A9-30-10 1SBL 141 001 R 10 MS325-9.00 1SAM 150 000 R1010 6.30 - 9.00 2 x A9-30-10 1SBL 141 001 R 10 MS325-9.00 1SAM 150 000 R1010 6.30 - 9.00 2 x A9-30-10 1SBL 141 001 R 10 MS325-12.5 1SAM 150 000 R1011 9.00 - 12.5 2 x A12-30-10 1SBL 161 001 R 10 MS325-16.0 1SAM 150 000 R1012 12.5 - 16.0 2 x A16-30-10 1SBL 181 001 R 10 MS325-20.0 1SAM 150 000 R1013 16.0 - 20.0 2 x A26-30-10 1SBL 241 001 R 10 MS325-25.0 1SAM 150 000 R1014 20.0 - 25.0 2 x A26-30-10 1SBL 241 001 R 10 MS450-32.0 1SAM 450 000 R1004 22.0 - 32.0 2 x A30-30-10 1SBL 281 001 R 10 MS450-40.0 1SAM 450 000 R1005 28.0 - 40.0 2 x A40-30-10 1SBL 321 001 R 10 MS450-50.0 1SAM 450 000 R1007 40.0 - 50.0 2 x A50-30-00 1SBL 351 001 R 00 MS495-63.0 1SAM 550 000 R1007 45.0 - 63.0 2 x A63-30-00 1SBL 371 001 R 00 MS495-75.0 1SAM 550 000 R1008 57.0 - 75.0 2 x A75-30-00 1SBL 411 001 R 00 MS495-90.0 1SAM 550 000 R1009 70.0 - 90.0 2 x A95-30-00 1SFL 431 001 R 00 MS495-100 1SAM 550 000 R1010 80.0 - 100 2 x A95-30-00 1SFL 431 001 R 00 Unit piece 4.8 7.56 12 12 19.2 19.2 30 48 48 75.6 135 135 187.5 240 300 375 384 480 600 756 900 1080 1200 state coil voltage code Unit piece Allowed Setting current A Connecting link between MS.. and contactors Interlock Connection Mounting unit set for the plate contactors 0.25 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.4 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.63 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 2.5 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 6.3 BEA 16/116 VE 5-1 BER 16V PM 26-23 9 BEA 16/325 VE 5-1 BER 16V PM 26-23 9 BEA 16/325 VE 5-1 BER 16V PM 26-23 12 BEA 16/325 VE 5-1 BER 16V PM 26-23 16 BEA 16/325 VE 5-1 BER 16V PM 26-23 20 BEA 26/325 VE 5-1 BER 40V PM 26-23 25 BEA 26/325 VE 5-1 BER 40V PM 26-23 30 BEA 40/450 VE 5-1 BER 40V – 38 BEA 40/450 VE 5-1 BER 40V – 47.5 BEA 50/450 VE 5-2 BEM 75-30 – 60 BEA 75/495 VE 5-2 BEM 75-30 – 72.5 BEA 75/495 VE 5-2 BEM 75-30 – 85 BEA 110/495 VE 5-2 BEM 110-30 – 96 BEA 110/495 VE 5-2 BEM 110-30 – >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 19 1SBC101001C0201 Reversing Starters Protected by Manual Motor Starter I> Coordination Type 2 Ordering Details - Coordination type 2, 400 V, 16 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.48 4 8.6 5.5 7.5 11.1 14.8 Contactor Accessories Current setting range A Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 1SAM 250 000 R1002 0.16 - 0.25 3 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.40 1SAM 250 000 R1003 0.25 - 0.40 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.63 1SAM 250 000 R1004 0.40 - 0.63 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-2.50 1SAM 250 000 R1007 1.60 - 2.50 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A16-30-10 1SBL 181 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A16-30-10 1SBL 181 001 R 10 MS116-6.30 1SAM 250 000 R1009 4.00 - 6.30 2 x A16-30-10 1SBL 181 001 R 10 MS116-10.0 1SAM 250 000 R1010 6.30 - 10.0 2 x A26-30-10 1SBL 241 001 R 10 MS116-10.0 1SAM 250 000 R1010 6.30 - 10.0 2 x A26-30-10 1SBL 241 001 R 10 MS116-12.0 1SAM 250 000 R1012 8.00 - 12.0 2 x A26-30-10 1SBL 241 001 R 10 MS116-16.0 1SAM 250 000 R1011 10.0 - 16.0 2 x A26-30-10 1SBL 241 001 R 10 Unit piece 4.8 7.56 12 12 19.2 19.2 30 48 48 75.6 120 120 144 192 state coil voltage code Unit piece Allowed Setting current A Connecting link between MS.. and contactors Interlock unit Connection Mounting set for the plate contactors 0.25 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.4 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.63 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 2.5 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 6.3 BEA 16/116 VE 5-1 BER 16V PM 26-23 10 BEA 26/116 VE 5-1 BER 40V PM 26-23 10 BEA 26/116 VE 5-1 BER 40V PM 26-23 12 BEA 26/116 VE 5-1 BER 40V PM 26-23 16 BEA 26/116 VE 5-1 BER 40V PM 26-23 Packing pieces Weight kg Ordering Details - Main Accessories Description Connecting links Type Order Code BEA 16/116 1SBN 081 406 R1000 10 0.020 BEA 26/116 1SBN 082 406 R1000 10 0.024 BEA 26/325 1SBN 082 406 R1001 10 0.031 BEA 40/450 1SBN 083 206 R1000 1 0.061 BEA 50/450 1SBN 083 506 R1000 1 0.062 BEA 75/495 1SBN 084 106 R1000 1 0.120 BEA 110/495 1SBN 084 506 R1000 1 0.124 Connection kit BSA 325 FPTN 472 772 R0001 1 0.009 Mechanical interlock unit VM 5-1 1SBN 030 100 R1000 1 0.066 Mechanical & electrical interlock units VE 5-1 1SBN 030 110 R1000 1 0.076 VE 5-2 1SBN 030 210 R1000 1 0.146 Connection sets Mounting plate BER 16V 1SBN 081 411 R1000 1 0.045 BER 40V 1SBN 082 411 R1000 1 0.085 BEM 75-30 1SBN 083 501 R1000 1 0.243 BEM 110-30 1SFN 084 301 R1000 1 0.450 PM 26-23 1SBN 091 407 R1000 1 0.330 >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 20 1SBC101001C0201 Reversing Starters Protected by Manual Motor Starter I> Coordination Type 2 Ordering Details - Coordination type 2, 400 V, 50 kA, 50/60 Hz IEC Manual Motor Starter AC-3, 400 V Rated Rated power current kW A Type Order Code 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 0.22 0.34 0.44 0.72 0.83 1.12 1.45 1.9 2.59 3.45 4.8 6.6 4 8.5 5.5 7.5 9 11.5 15.5 18.3 11 15 18.5 22 30 37 45 51 22 30 37 44 60 72 85 94 Contactor Accessories Current setting range A Magnetic tripping current A Type state coil voltage Order Code MS116-0.25 1SAM 250 000 R1002 0.16 - 0.25 3 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.40 1SAM 250 000 R1003 0.25 - 0.40 2 x A9-30-10 1SBL 141 001 R 10 MS116-0.63 1SAM 250 000 R1004 0.40 - 0.63 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.00 1SAM 250 000 R1005 0.63 - 1.00 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-1.60 1SAM 250 000 R1006 1.00 - 1.60 2 x A9-30-10 1SBL 141 001 R 10 MS116-2.50 1SAM 250 000 R1007 1.60 - 2.50 2 x A9-30-10 1SBL 141 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A16-30-10 1SBL 181 001 R 10 MS116-4.00 1SAM 250 000 R1008 2.50 - 4.00 2 x A16-30-10 1SBL 181 001 R 10 MS116-6.30 1SAM 250 000 R1009 4.00 - 6.30 2 x A16-30-10 1SBL 181 001 R 10 MS325-9.00 1SAM 150 000 R1010 6.30 - 9.00 2 x A26-30-10 1SBL 241 001 R 10 MS325-9.00 1SAM 150 000 R1010 6.30 - 9.00 2 x A26-30-10 1SBL 241 001 R 10 MS325-12.5 1SAM 150 000 R1011 9.00 - 12.5 2 x A26-30-10 1SBL 241 001 R 10 MS325-16.0 1SAM 150 000 R1012 12.5 - 16.0 2 x A26-30-10 1SBL 241 001 R 10 MS325-20.0 1SAM 150 000 R1013 16.0 - 20.0 2 x A26-30-10 1SBL 241 001 R 10 MS325-25.0 1SAM 150 000 R1014 20.0 - 25.0 2 x A30-30-10 1SBL 281 001 R 10 MS450-32.0 1SAM 450 000 R1004 22.0 - 32.0 2 x A40-30-10 1SBL 321 001 R 10 MS450-40.0 1SAM 450 000 R1005 28.0 - 40.0 2 x A40-30-10 1SBL 321 001 R 10 MS450-50.0 1SAM 450 000 R1007 40.0 - 50.0 2 x A63-30-00 1SBL 371 001 R 00 MS495-63.0 1SAM 550 000 R1007 45.0 - 63.0 2 x A75-30-00 1SBL 411 001 R 00 MS495-75.0 1SAM 550 000 R1008 57.0 - 75.0 2 x A75-30-00 1SBL 411 001 R 00 MS495-90.0 1SAM 550 000 R1009 70.0 - 90.0 2 x A95-30-00 1SFL 431 001 R 00 MS495-100 1SAM 550 000 R1010 80.0 - 100 2 x A95-30-00 1SFL 431 001 R 00 Unit piece 4.8 7.56 12 12 19.2 19.2 30 48 48 75.6 135 135 187.5 240 300 375 384 480 600 756 900 1080 1200 state coil voltage code Unit piece Allowed Setting current A Connecting link between MS.. and contactors Interlock Connection unit set for the contactors Mounting plate 0.25 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.4 BEA 16/116 VE 5-1 BER 16V PM 26-23 0.63 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 1.6 BEA 16/116 VE 5-1 BER 16V PM 26-23 2.5 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 4 BEA 16/116 VE 5-1 BER 16V PM 26-23 6.3 BEA 16/116 VE 5-1 BER 16V PM 26-23 9 BEA 26/325 VE 5-1 BER 40V PM 26-23 9 BEA 26/325 VE 5-1 BER 40V PM 26-23 12.5 BEA 26/325 VE 5-1 BER 40V PM 26-23 16 BEA 26/325 VE 5-1 BER 40V PM 26-23 20 BEA 26/325 VE 5-1 BER 40V PM 26-23 25 BSA 325 VE 5-1 BER 40V – 30 BEA 40/450 VE 5-1 BER 40V – 38 BEA 40/450 VE 5-1 BER 40V – 47.5 BEA 50/450 VE 5-2 BEM 75-30 – 60 BEA 75/495 VE 5-2 BEM 75-30 – 72.5 BEA 75/495 VE 5-2 BEM 75-30 – 85 BEA 110/495 VE 5-2 BEM 110-30 – 96 BEA 110/495 VE 5-2 BEM 110-30 – >> Coil Voltage Codes ..............................................................................................................................................................................................................pages 0/1, 0/2 in the Cover Flap >> Accessories, Ordering Details .................................................................................................................................................................................................................................... page 57 >> Other Manual Motor Starters and Contactors ............................................................................................................................................................................................. Main Catalogue 21 1SBC101001C0201 Direct-On-Line Starters Open Type Version in Kit Form I> Protection by Manual Motor Starter KM1 : 5/L3 KM1 : 5/L3 Us Us Q1 Q1 Power Circuit 22 1SBC101001C0201 14 14 KM1 E3025D A1 A1 KM1 Remote Control Local Control E3027D KM1 Us N KM1 : 3/L2 A2 Us N KM1 : 3/L2 E3026D 14 6/T3 4/T2 2/T1 A2 3 I KM1 U1 V1 W1 M 13 13 I KM1 A2 6/T3 5/L3 13 4/T2 O A1 2/T1 I> 3/L2 I> 1/L1 I> 14 14 22 14 Q1 13 13 21 13 5/L3 3/L2 1/L1 Wiring Diagrams Reversing Starters Open Type Version in Kit Form I> Protection by Manual Motor Starter KM2 : 5/L3 Us Q1 Q1 II 14 14 KM2 Power Circuit Remote Control 22 E3030D KM2 A2 Us N KM2 : 3/L2 A2 A2 KM2 E3029D M 3 A1 22 A1 22 A1 A1 KM1 A2 Us N KM2 : 3/L2 KM1 KM2 KM1 U1 V1 W1 21 21 KM1 22 KM2 21 21 E3028D 22 14 KM1 14 I KM2 13 13 13 13 21 5/L3 3/L2 1/L1 13 14 6/T3 4/T2 2/T1 I A2 22 14 6/T3 4/T2 2/T1 KM2 KM1 A1 21 13 5/L3 3/L2 A1 1/L1 II A2 14 O I> 6/T3 4/T2 I> 2/T1 I> 22 14 14 Q1 KM1 13 13 KM2 : 5/L3 Us 21 13 5/L3 3/L2 1/L1 Wiring Diagrams for Reversing Starters With or without VM 5-1 mechanical interlock unit, electrical interlocking by built-in auxiliary contacts Local Control 13 13 KM2 : 5/L3 Us Q1 Q1 14 13 KM2 : 5/L3 Us 21 5/L3 3/L2 1/L1 Wiring Diagrams for Reversing Starters With VE 5-.. mechanical and electrical interlock unit 14 22 14 Q1 O I> Power Circuit 14 KM2 14 14 13 13 13 14 Remote Control 01 02 02 A1 A1 A1 01 01 02 01 02 A1 3 II KM2 E3033D Us N KM2 : 3/L2 A2 E3032 D KM2 A2 KM1 KM1 Us N KM2 : 3/L2 A2 M KM1 14 6/T3 4/T2 E3031D U1 V1 W1 I KM2 A2 5/L3 13 3/L2 A1 1/L1 KM1 I 2/T1 02 02 14 6/T3 A2 01 01 13 5/L3 3/L2 4/T2 KM2 2/T1 A2 KM1 A1 1/L1 II 13 6/T3 4/T2 I> 2/T1 I> Local Control 23 1SBC101001C0201 A 9 ... A 26 3-pole Contactors Protected by Manual Motor Starter I> Direct-On-Line Starter Dimensions (in mm) 75.5 85.6 70 4.5 6 5 10 54 5 62 180 35 mm EN/IEC 60715 15 180 10 15 10 44 5 A 9, A 12, A 16 contactors + BEA 16/325 + MS 325 106 96 101 91 35 mm EN/IEC 60715 4.5 4.5 7.3 4 x ø 4.2 E2660D 215 2 x ø 7.2 45 A 26 contactor + BEA.. + MS.. + PM 26-13 Drilling plan 24 1SBC101001C0201 10 10 7.7 107 A 26 contactor + BEA 26/325 + MS 325 + PM 26-13 113 E2666D 113 E2664D 107 E2667D 10 54 7.7 A 26 contactor + BEA 26/116 + MS 116 + PM 26-13 15 39.4 125 225 125 15 10 39.4 E2665D 54 8 5 35 mm EN/IEC 60715 5 10 15 25 20 5 225 5 E2090D 5 10 4.5 E2089D 35 40 A 9, A 12, A 16 contactors + BEA 16/116 + MS 116 4.5 E2084D 5.5 10 44 E2083D E2082D 7 5 177 35 mm EN/IEC 60715 45 10 25 5 40 5 17.5 80.1 43 45 A 30, A 40 3-pole Contactors Protected by Manual Motor Starter I> Direct-On-Line Starter Dimensions (in mm) 96 4 x ø 4.2 7.3 13 25 5 4.5 4.5 91 8 5 215 10 45 E2865D 122 E2660D 7.7 10 54 E2864D 39.4 125 15 35 mm EN/IEC 60715 225 2 x ø 7.2 128.3 A 30, A 40 contactors + BEA 26/325 + MS 325 149 55 8 5 12 30 5.2 245 15 140 255 130 50 5 10 70 5 37.5 6.3 108.3 4.5 45 4.5 E2100D E2098D 9 54 E2099D 5 10 4.2 A 30, A 40 contactors + BEA 40/450 + MS 450 25 1SBC101001C0201 A 50, A 63 3-pole Contactors Protected by Manual Motor Starter I> Direct-On-Line Starter Dimensions (in mm) 149 8 12 5.2 30 50 55 5 260 15 145 270 130 5 5 10 90 45 A 50, A 63 contactors + BEA 50/450 + MS 450 26 1SBC101001C0201 6.5 108 5 60 5 E2103D 10 E2102D 70 E2101D 5 10 6.2 A 63 ... A 110 3-pole Contactors Protected by Manual Motor Starter I> Direct-On-Line Starter Dimensions (in mm) 169 8 12 5.2 30 70 70 5 165 15 292,5 302.5 155 5 5 10 90 45 70 6.5 5 E2105D E2104D 10 108 60 5 E2106D 5 10 6.2 A 63, A 75 contactors + BEA 75/495 + MS 495 169 8 12 5.2 30 70 70 5 155 5 330 341.5 185 15 54 136 5 20 6.5 123.5 6 78 6 E2109D E2107D 10 90 E2108D 5 10 7 A 95, A 110 contactors + BEA 110/495 + MS 495 27 1SBC101001C0201 A 9 ... A 16 3-pole Contactors Protected by Manual Motor Starter I> Reversing Starter Dimensions (in mm) 106 96 91 26 25 29.5 40 101 10 5 8 125 12 5 35 mm EN/IEC 60715 15 225 125 35 mm EN/IEC 60715 225 5 15 12 95 7.7 88 A 9, A 12, A 16 contactors + VM/VE 5-1 + BEA 16/325 + BER 16V + MS 325 + PM 26-23 95 106 96 101 91 26 25 29.5 40 E2847D A 9, A 12, A 16 contactors + VM/VE 5-1 + BEA 16/116 + BER 16V + MS 116 + PM 26-23 10 39.4 108 88 E2846D 7.7 E2843D 108 10 E2842D 39.4 5 10 5 8 12 125 225 15 35 mm EN/IEC 60715 35 mm EN/IEC 60715 125 225 5 15 12 10 4.5 45 45 95 4.5 7.3 8 x ø 4.2 99 E2671D 215 4 x ø 7.2 A 9, A 12, A 16 + BEA.. + MS... + PM 26-23 Drilling plan 28 1SBC101001C0201 A 9, A 12, A 16 contactors + BEA 16/325 + BER 16 + MS 325 + PM 26-23 7.7 88 95 E2849D A 9, A 12, A 16 contactors + BEA 16/116 + BER 16 + MS 116 + PM 26-23 108 10 39.4 88 E2848D 7.7 E2845D 108 10 E2844D 39.4 10 A 26 3-pole Contactors Protected by Manual Motor Starter I> Reversing Starter 106 96 101 91 10 8 5 125 225 15 35 mm EN/IEC 60715 15 10 10 123 A 26 contactors + VM/VE 5-1 + BEA 26/116 + BER 40V + MS 116 + PM 26-23 113 106 7.7 107 A 26 contactors + VM/VE 5-1 + BEA 26/325 + BER 40V + MS 325 + PM 26-23 113 96 101 10 8 5 125 225 15 35 mm EN/IEC 60715 15 10 10 45 113 45 107 A 26 contactors + BEA 26/325 + BER 40 + MS 325 + PM 26-23 4.5 4.5 4.5 7.7 113 E2854D A 26 contactors + BEA 26/116 + BER 40 + MS 116 + PM 26-23 4.5 4.5 4 x ø 4.2 7.3 4 x ø 7.2 4 x ø 7.2 215 215 7.3 4 x ø 4.2 99 E2671D1 45 A 26 + BEA.. + MS... + PM 26-23 Drilling plan 45 114 E2670D1 4.5 108 107 10 7.7 E2851D 108 E2855D E2852D 10 39.4 39.4 125 35 mm EN/IEC 60715 16 20 25 40 91 5 225 E2854D 107 10 7.7 E2851D 123 E2853D E2850D 10 39.4 39.4 125 35 mm EN/IEC 60715 225 5 16 20 25 40 Dimensions (in mm) A 26 + VM/VE 5-1 + BEA.. + MS... + PM 26-23 Drilling plan 29 1SBC101001C0201 A 30, A 40 3-pole Contactors Protected by Manual Motor Starter I> Reversing Starter Dimensions (in mm) 149 55 8 5 12 30 2 x 5.2 245.4 15 140 260 130 50 5 10 37.5 70 5 7.5 4.2 5 6.3 108.3 45 4.5 E3018D 10 108 E3017D 9 A 30, A 40 contactors + VM/VE 5-1 + BEA 40/450 + BER 40V + MS 450 69 4.5 Drilling plan 149 55 8 5 12 30 2 x 5.2 245.4 15 140 260 130 50 5 10 37.5 70 5 7.5 4.2 30 1SBC101001C0201 10 6.3 108.3 E3021D 5 A 30, A 40 contactors + BEA 40/450 + BER 40 + MS 450 E3020D 9 108 4.5 45 Drilling plan 54 4.5 E3022D 5 (M4) E3019D 5 (M4) Notes 31 1SBC101001C0201 Starting Solution with Bus-bar System smissline-S Direct-On-Line and Reversing Starters with Manual Motor Starters up to 11 kW Compact and flexible solution The smissline Bus-bar System offers the efficient, flexible and rapid mounting of components. The socket bases can be combined in any order. The bus-bars are fitted to the 6 and 8-way modular sockets (and additional sockets) and according to requirements. The advantage of the Combi moduls is that any desired combinations of smissline units can be formed into a unit with conventional devices. These can be replaced very quickly and keeps the downtime of systems to a minimum. Motor starter solution The direct and reversing starters are possible up to 11 kW with A9 to A26 contactors associated to MS116 or MS325 manual motor starter with a BEA connecting link, and fixed on a single combi-modul. The use of one single combi-modul with one combi-modul without wire (ref ZLS840) allows the possibility to assemble a reversing starter. The product selection according to the coordination tables is detailed in the catalogue tables (see page 12 to 21) Your advantage: ● Keep the downtime of systems to a minimum ● Components interchangeable at any time ● Compact energy distribution - up to max. 200 A ( ● Full scope for the future ● Completely touch proof ● Easy maintenance 150 A) For complete information on the smissline system, please consult the specific catalogue or the ABB website. 32 1SBC101001C0201 Starting Solution with Bus-bar System smissline-S Combi Modul and Accessories Technical data IEC/EN60439-2 Rated voltage Ue: 400/690 V Rated short-time withstand current Icw: 10 kA / 300 ms Rated current Ie: 32 A (L1, L2, L3, N) - 6 A (La, Lb auxiliary circuits) Moduls: 3 (54 mm) Approbation: c us, IEC / EN60439-2 Ordering details Description Modules Type Order code Packing unit Weight kg Combi-modul single containing L1, L2, L3 top feed 3 ZLS8403LWT-S 2CCA 180 451 R0001 1 0.085 Combi-modul single containing L1, L2, L3, N top feed 3 ZLS8403LNWT-S 2CCA 180 452 R0001 1 0.090 Combi-modul single containing L1, L2, L3 top feed, La 3 ZLS8403LAWT-S 2CCA 180 470 R0001 1 0.090 Combi-modul single containing L1, L2, L3 top feed, La, Lb 3 ZLS8403LABWT-S 2CCA 180 453 R0001 1 0.095 Combi-modul single containing L1, L2, L3, N top feed, La 3 ZLS8403LNAWT-S 2CCA 180 471 R0001 1 0.095 Combi-modul single containing L1, L2, L3, N top feed, La, Lb 3 ZLS8403LNABWT-S 2CCA 180 454 R0001 1 0.100 Combi-modul single containing L1, L2, L3 bottom feed 3 ZLS8403LWB-S 2CCA 180 462 R0001 1 0.085 Combi-modul single containing L1, L2, L3, N bottom feed 3 ZLS8403LNWB-S 2CCA 180 463 R0001 1 0.090 Combi-modul single containing L1, L2, L3 bottom feed, La 3 ZLS8403LAWB-S 2CCA 180 472 R0001 1 0.090 Combi-modul single containing L1, L2, L3 bottom feed, La, Lb 3 ZLS8403LABWB-S 2CCA 180 464 R0001 1 0.095 Combi-modul single containing L1, L2, L3, N bottom feed, La 3 ZLS8403LNAWB-S 2CCA 180 473 R0001 1 0.095 Combi-modul single containing L1, L2, L3, N bottom feed, La, Lb 3 ZLS8403LNABWB-S 2CCA 180 465 R0001 1 0.100 ZLS840 2CCA 180 450 R0001 1 0.045 Connecting element for combi-modul (3 connectors per module) - bag of 12 ZLS519 2CCA 017 429 R0001 1 bag – Fixing for contactor and motor protection circuit-breaker - bag of 10 ZLS518 2CCF 002 792 R0001 1 bag 0.020 Fixing for contactor - bag of 10 ZLS522 2CCF 017 540 R0001 1 bag 0.030 Combi-modul wire top feed Combi-modul wire bottom feed Wire top feed Combi-modul without plug-in contacts Combi-modul without wire Accessories Combi-modul Dimensions 44.5 ZLS... 99 ... 162 35.2 180 35.2 Wire bottom feed US C 54 US 13 108 30.1 7.5 Z200465.eps C 33 1SBC101001C0201 Direct-On-Line and Reversing Starters Open Type Version, in Kit Form Protected by Thermal Overload Relay A9 ... A110 BER, BEM A9 ... A110 A9 ... A110 TA .. DU TA .. DU Direct-On-Line Starters 3-pole a.c. operated contactors A9 A 12 A 16 A 26 A 30 A 40 A 50 A 63 TA 25 DU TA 75 DU 0.1 ... 0.16 A to 24 ... 32 A 18 ... 25 A to 60 ... 80 A Thermal overload relays A 75 A 95 A 110 TA 80 DU 29 ... 42 A to 60 ... 80 A TA 42 DU TA 110 DU 18 ... 25 A to 29 ... 42 A 65 ... 90 A to 80 ... 110 A Reversing Starters 3-pole a.c. operated contactors A9 A 12 A 16 A 26 A 30 A 40 A 50 A 63 A 75 A 95 A 110 Connection sets BER 16V (1) BER 40V (1) BEM 75-30 BEM 110-30 TA 25 DU TA 75 DU TA 80 DU 0.1 ... 0.16 A to 24 ... 32 A 18 ... 25 A to 60 ... 80 A 29 ... 42 A to 60 ... 80 A Thermal overload relays TA 42 DU TA 110 DU 18 ... 25 A to 29 ... 42 A 65 ... 90 A to 80 ... 110 A Mechanical / electrical interlock units VM 5-1 / VE 5-1 VE 5-2 (1) If only an electrical interlocking is required between contactors A 9 up to A 40, use BER 16 and BER 40 connection sets for contactors with N.C. built-in auxiliary contacts. 34 1SBC101001C0201 Direct-On-Line and Reversing Starters Open Type Version, in Kit Form Protected by Thermal Overload Relay Application Direct-on-line and reversing starters for controlling three-phase asynchronous motors: - for a maximum operational voltage up to 690 V - 50 or 60Hz - for a switching frequency of < 15 starts an hour with a load factor of 80 % of < 30 starts an hour with a load factor of 50 % - with an ambient temperature near the devices of < 55 °C Coordination See "Online Product Selection Tools" on "www.abb.com/lowvoltages" website. Click on "Online Selected Optimized Coordinations" to display the required coordination table according to the short-circuit protection device and the coordination type complying with IEC/EN 60947-4-1. Mounting and Connection Accessory Description BER or BEM connection sets allow to assemble quickly reversing starters. These accessories eliminate the potential risk of wiring errors, reduce the time required to install and to maintain reversing starters. For the reversing contactors the interlocking can be easily assured by a simple mounting between both contactors of: - a VE 5-.. interlock unit for a mechanical and electrical interlocking - a VM 5-1 interlock unit for a mechanical interlocking and add-on N.C. aux. contacts for the electrical interlocking (or use contactors with built-in N.C. aux. contacts). Nota: If only an electrical interlocking is required between 3-pole contactors A 9 up to A 40, select contactors with add-on or built-in N.C. auxiliary contacts associated with BER 16 and BER 40 connection sets (A 9-30-01 ... A 40-30-01 contactors, see main catalogue). Direct-On-Line Starters - Selection and Ordering Details Reversing Starters - Selection and Ordering Details (for coil voltage codes and overload relay ranges, see pages 0/1 and 0/2 in the cover flap) (for coil voltage codes and overload relay ranges, see pages 0/1 and 0/2 in the cover flap) Rated Power AC-3 kW 4 5.5 7.5 11 15 18.5 22 30 37 45 55 Contactor KM1 Type Thermal Overload Relay Type state coil voltage state max. setting range Order Code Order Code state coil voltage code state setting range code Rated Power Contactors KM1 + KM2 Type AC-3 kW A 9-30-10 1SBL 141 001 R TA 25 DU 1SAZ 211 201 R10 4 10 A 12-30-10 1SBL 161 001 R TA 25 DU 1SAZ 211 201 R10 5.5 10 A 16-30-10 1SBL 181 001 R TA 25 DU 1SAZ 211 201 R10 7.5 10 A 26-30-10 1SBL 241 001 R TA 25 DU 1SAZ 211 201 R10 11 10 A 30-30-10 1SBL 281 001 R TA 25 DU 1SAZ 211 201 R10 15 10 A 40-30-10 1SBL 321 001 R TA 42 DU 1SAZ 311 201 R10 18.5 10 A 50-30-00 1SBL 351 001 R TA 75 DU 1SAZ 321 201 R10 22 00 A 63-30-00 1SBL 371 001 R TA 75 DU 1SAZ 321 201 R10 30 00 A 75-30-00 1SBL 411 001 R TA 75 DU 1SAZ 321 201 R10 37 00 A 95-30-00 1SFL 431 001 R TA 110 DU 1SAZ 411 201 R10 45 00 A 110-30-00 1SFL 451 001 R TA 110 DU 1SAZ 411 201 R10 55 00 Thermal Overload Relay Type state coil voltage state max. setting range Order Code Order Code state coil voltage code state setting range code Interlock Unit Connection Set Type Type 2 x A 9-30-10 1SBL 141 001 R TA 25 DU 1SAZ 211 201 R10 VE 5-1 BER 16V 10 2 x A 12-30-10 1SBL 161 001 R TA 25 DU 1SAZ 211 201 R10 VE 5-1 BER 16V 10 2 x A 16-30-10 1SBL 181 001 R TA 25 DU 1SAZ 211 201 R10 VE 5-1 BER 16V 10 2 x A 26-30-10 1SBL 241 001 R TA 25 DU 1SAZ 211 201 R10 VE 5-1 BER 40V 10 2 x A 30-30-10 1SBL 281 001 R TA 25 DU 1SAZ 211 201 R10 VE 5-1 BER 40V 10 2 x A 40-30-10 1SBL 321 001 R TA 42 DU 1SAZ 311 201 R10 VE 5-1 BER 40V 10 2 x A 50-30-00 1SBL 351 001 R TA 75 DU 1SAZ 321 201 R10 VE 5-2 BEM 75-30 00 2 x A 63-30-00 1SBL 371 001 R TA 75 DU 1SAZ 321 201 R10 VE 5-2 BEM 75-30 00 2 x A 75-30-00 1SBL 411 001 R TA 75 DU 1SAZ 321 201 R10 VE 5-2 BEM 75-30 00 2 x A 95-30-00 1SFL 431 001 R TA 110 DU 1SAZ 411 201 R10 VE 5-2 BEM 110-30 00 2 x A 110-30-00 1SFL 451 001 R TA 110 DU 1SAZ 411 201 R10 VE 5-2 BEM 110-30 00 Ordering Details - Main Accessories Description Type Order Code Packing pieces Mechanical interlock unit VM 5-1 1SBN 030 100 R1000 1 0.066 Mechanical & electrical interlock units VE 5-1 1SBN 030 110 R1000 1 0.076 VE 5-2 1SBN 030 210 R1000 1 0.146 BER 16V 1SBN 081 411 R1000 1 0.045 BER 40V 1SBN 082 411 R1000 1 0.085 BEM 75-30 1SBN 083 501 R1000 1 0.243 BEM 110-30 1SFN 084 301 R1000 1 0.450 Connection sets >> Other accessories, ordering details ............................................................. page 57 Weight kg >> Other contactor and thermal overload relay types ...................... Main Catalogue 35 1SBC101001C0201 Star-Delta Starters without Interlock Unit Open Type Version, in Kit Form Δ L Y Protected by Thermal Overload Relay 1 KM TE5S 3 KM 2 KM CA 5-.. TA .. DU BEY, BED Star-Delta Starters without interlock unit - Mounting: Star KM2 - Delta KM3 - Line KM1 Contactors 3-pole a.c. operated contactors KM3 KM1 A9 A9 A9 A12 A12 A16 A9 A12 A16 Connection sets BEY 16-1 KM2 KM3 KM1 A16 A26 A26 BEY 26-1 KM2 KM3 KM1 A26 A30 A30 A26 A40 A40 BEY 40-1 KM2 KM3 KM1 KM2 KM3 A30 A50 A50 A40 A63 A63 A50 A75 A75 BED 50-1 BED 75-1 3 KM2 KM3 KM1 A75 A95 A95 BED 95 Additional auxiliary contact blocks CA 5-10 KM2 CA 5-10 KM3 – TA 75 DU TA 110 DU 0.1 ... 0.16 A to 24 ... 32 A 18 ... 25 A to 60 ... 80 A 65 ... 90 A to 80 ... 110 A TA 42 DU 18 ... 25 A to 29 ... 42 A Timers TE5S-24 or TE5S-120 or TE5S-240 or TE5S-440 Mounting plate – 36 1SBC101001C0201 KM1 A95 A110 A110 2 x CA 5-10 1 x CA 5-10 + 1 x CA 5-01 CA 5-01 TA 25 DU Thermal overload relays KM3 5 2 x CA 5-10 CA 5-10 CA 5-01 KM1 KM2 BED 110 E1143D 1 KM1 E2123D KM2 PN 110-41 Star-Delta Starters without Interlock Unit Open Type Version, in Kit Form Δ L Y Protected by Thermal Overload Relay Application Star-delta starters without interlock unit for controlling three-phase asynchronous motors: - for a maximum operational voltage up to 690 V - 50 or 60 Hz - with an ambient temperature near the devices of < 55 °C - switching frequency / hour, see page 5. Coordination See "Online Product Selection Tools" on "www.abb.com/lowvoltage" website. Click on "Online Selected Optimized Coordinations" to display the required coordination table according to the short-circuit protection device and the coordination type complying with IEC / EN 60947-4-1. Mounting and Connection Accessory Description BEY or BED connection sets allow to assemble quickly star-delta starters without interlock unit, with contactors assembled according to a stardelta-line mounting. These accessories eliminate the potential risk of wiring errors, reduce the time required to install and to maintain star-delta starters. Electrical interlocking is realized with N.C. built-in or add-on auxiliary contacts of both Star and Delta contactors. Variants For star-delta starters 7.5 kW up to 37 kW with contactors mounted according to a line-delta-star mounting, select BEY 16-2, BEY 26-2 and BEY 40-2 connection sets. Star-Delta Starters - Selection and Ordering Details (for coil voltage codes and thermal overload relay ranges, see pages 0/1 and 0/2 in the cover flap) Rated Power 400 V Rated Power 415 V Rated Power 690 V Star Contactor KM2 Type Delta Contactor KM3 Type Line Contactor KM1 Type Thermal Overload Relay (1) Type Connection Set Type Order Code state coil voltage state coil voltage state coil voltage Order Code Order Code Order Code state max. setting range Order Code state setting range code kW kW kW state coil voltage code state coil voltage code state coil voltage code 7.5 7.5 5.5 A 9-30-01 1SBL 141 001 R A 9-30-01 01 1SBL 141 001 R A 9-30-10 01 1SBL 141 001 R TA 25 DU 10 1SAZ 211 201 R10 BEY 16-1 1SBN 081 413 R1000 11 11 7.5 A 9-30-01 1SBL 141 001 R A 12-30-01 01 1SBL 161 001 R A 12-30-10 01 1SBL 161 001 R TA 25 DU 10 1SAZ 211 201 R10 BEY 16-1 1SBN 081 413 R1000 15 15 11 A 12-30-01 1SBL 161 001 R A 16-30-01 01 1SBL 181 001 R A 16-30-10 01 1SBL 181 001 R TA 25 DU 10 1SAZ 211 201 R10 BEY 16-1 1SBN 081 413 R1000 22 22 15 A 16-30-01 1SBL 181 001 R A 26-30-01 01 1SBL 241 001 R A 26-30-10 01 1SBL 241 001 R TA 25 DU 10 1SAZ 211 201 R10 BEY 26-1 1SBN 082 413 R1000 25 25 18.5 A 26-30-01 1SBL 241 001 R A 30-30-01 01 1SBL 281 001 R A 30-30-10 01 1SBL 281 001 R TA 25 DU 10 1SAZ 211 201 R10 BEY 40-1 1SBN 082 813 R1000 37 37 37 A 26-30-01 1SBL 241 001 R A 40-30-01 01 1SBL 321 001 R A 40-30-10 01 1SBL 321 001 R TA 42 DU 10 1SAZ 311 201 R10 BEY 40-1 1SBN 082 813 R1000 45 45 45 A 30-30-01 1SBL 281 001 R A 50-30-00 01 1SBL 351 001 R A 50-30-00 00 1SBL 351 001 R TA 75 DU 00 1SAZ 321 201 R10 BED 50-1 1SBN 083 503 R1001 55 55 59 A 40-30-01 1SBL 321 001 R A 63-30-00 01 1SBL 371 001 R A 63-30-00 00 1SBL 371 001 R TA 75 DU 00 1SAZ 321 201 R10 BED 50-1 1SBN 083 503 R1001 63 70 63 A 50-30-00 1SBL 351 001 R A 75-30-00 00 1SBL 411 001 R A 75-30-00 00 1SBL 411 001 R TA 75 DU 00 1SAZ 321 201 R10 BED 75-1 1SBN 084 103 R1001 75 75 90 A 75-30-00 1SBL 411 001 R A 95-30-00 00 1SFL 431 001 R A 95-30-00 00 1SFL 431 001 R TA 110 DU 00 1SAZ 411 201 R10 BED 95 1SFN 084 303 R1000 90 100 132 A 95-30-00 1SFL 431 001 R A 110-30-00 00 1SFL 451 001 R A 110-30-00 00 1SFL 451 001 R TA 110 DU 00 1SAZ 411 201 R10 BED 110 1SFN 084 503 R1000 (1) The setting current value is: nominal motor current x 0.58 Ordering Details - Main Accessories Description Rated control voltage Uc Auxiliary contact blocks Electronic timers Mounting plate Type Order Code Packing pieces Weight kg CA 5-10 1SBN 010 010 R1010 10 0.014 CA 5-01 1SBN 010 010 R1001 10 0.014 24 V a.c./d.c. TE5S-24 1SBN 020 010 R1001 1 0.080 110 ... 120 V a.c. TE5S-120 1SBN 020 010 R1002 1 0.080 220 ... 240 V a.c. TE5S-240 1SBN 020 010 R1003 1 0.080 380 ... 440 V a.c. TE5S-440 1SBN 020 010 R1004 1 0.080 PN 110-41 1SFN 094 303 R1000 1 0.950 >> Other accessories, ordering details ............................................................. page 57 >> Other contactor and thermal overload relay types ...................... Main Catalogue 37 1SBC101001C0201 Star-Delta Starters with Interlock Unit Open Type Version, in Kit Form Δ L Y Protected by Thermal Overload Relay 1 KM TE5S 3 KM . 2 KM 5-. VE CA 5-.. TA .. DU BEY, BED Star-Delta Starters with interlock unit - Mounting: Star KM2 - Delta KM3 - Line KM1 Contactors 3-pole a.c. operated contactors KM2 KM3 KM1 A9 A9 A9 A12 A12 A16 A9 A12 A16 Connection sets BEY 16V-1 KM2 KM3 KM1 A16 A26 A26 BEY 26-1 KM2 KM3 KM1 A26 A30 A30 A26 A40 A40 BEY 40-1 KM2 KM3 KM1 KM2 KM3 A30 A50 A50 A40 A63 A63 A50 A75 A75 BED 50 BED 75 KM1 KM2 KM3 KM1 A75 A95 A95 BED 95 KM2 KM3 A95 A110 A110 BED 110 E0917D E2123D BED 75 Additional auxiliary contact blocks CA 5-10 KM2 – 2 x CA 5-10 – KM1 2 x CA 5-10 1 x CA 5-10 TA 25 DU TA 75 DU TA 110 DU 0.1 ... 0.16 A to 24 ... 32 A 18 ... 25 A to 60 ... 80 A 65 ... 90 A to 80 ... 110 A Thermal overload relays TA 42 DU 18 ... 25 A to 29 ... 42 A Interlock units VE 5-1 VE 5-2 Timers TE5S-24 or TE5S-120 or TE5S-240 or TE5S-440 Mounting plate – 38 1SBC101001C0201 KM1 PN 110-41 Star-Delta Starters with Interlock Unit Open Type Version, in Kit Form Δ L Y Protected by Thermal Overload Relay Application Star-delta starters with electrical and mechanical interlock unit for controlling three-phase asynchronous motors: - for a maximum operational voltage up to 690 V - 50 or 60 Hz - with an ambient temperature near the devices of < 55 °C - switching frequency / hour, see page 5. Coordination See "Online Product Selection Tools" on "www.abb.com/lowvoltage" website. Click on "Online Selected Optimized Coordinations" to display the required coordination table according to the short-circuit protection device and the coordination type complying with IEC / EN 60947-4-1. Mounting and Connection Accessory Description BEY or BED connection sets allow to assemble quickly star-delta starters with electrical and mechanical interlock unit, with contactors assembled according to a star-delta-line mounting. These accessories eliminate the potential risk of wiring errors, reduce the time required to install and to maintain star-delta starters. Electrical interlocking is realized with N.C. auxiliary contacts of the VE5-.. interlock unit. Variants For star-delta starters 7.5 kW up to 37 kW with contactors mounted according to a line-delta-star mounting, select BEY 16V-2, BEY 26-2 and BEY 40-2 connection sets. Star-Delta Starter - Selection and Ordering Details (for coil voltage codes and thermal overload relay ranges, see pages 0/1 and 0/2 in the cover flap) Rated Power 400 V Rated Power 415 V Rated Power 690 V Star Contactor KM2 Type Delta Contactor KM3 Type Line Contactor KM1 Type Thermal Overload Relay (1) Type Interlock Unit Connection Set state coil voltage state coil voltage state coil voltage state max. setting range kW kW kW Order Code Order Code Order Code Order Code state coil voltage code state coil voltage code state coil voltage code state setting range code Type Type 7.5 7.5 5.5 A 9-30-10 1SBL 141 001 R 10 A 9-30-10 1SBL 141 001 R 10 A 9-30-10 1SBL 141 001 R 10 TA 25 DU 1SAZ 211 201 R10 VE 5-1 BEY 16V-1 11 11 7.5 A 9-30-10 1SBL 141 001 R 10 A 12-30-10 1SBL 161 001 R 10 A 12-30-10 1SBL 161 001 R 10 TA 25 DU 1SAZ 211 201 R10 VE 5-1 BEY 16V-1 15 15 11 A 12-30-10 1SBL 161 001 R 10 A 16-30-10 1SBL 181 001 R 10 A 16-30-10 1SBL 181 001 R 10 TA 25 DU 1SAZ 211 201 R10 VE 5-1 BEY 16V-1 22 22 15 A 16-30-10 1SBL 181 001 R 10 A 26-30-10 1SBL 241 001 R 10 A 26-30-10 1SBL 241 001 R 10 TA 25 DU 1SAZ 211 201 R10 VE 5-1 BEY 26-1 25 25 18.5 A 26-30-10 1SBL 241 001 R 10 A 30-30-10 1SBL 281 001 R 10 A 30-30-10 1SBL 281 001 R 10 TA 25 DU 1SAZ 211 201 R10 VE 5-1 BEY 40-1 37 37 37 A 26-30-10 1SBL 241 001 R 10 A 40-30-10 1SBL 321 001 R 10 A 40-30-10 1SBL 321 001 R 10 TA 42 DU 1SAZ 311 201 R10 VE 5-1 BEY 40-1 45 45 45 A 30-30-10 1SBL 281 001 R 10 A 50-30-00 1SBL 351 001 R A 50-30-00 00 1SBL 351 001 R TA 75 DU 00 1SAZ 321 201 R10 VE 5-2 BED 50 55 55 59 A 40-30-10 1SBL 321 001 R 10 A 63-30-00 1SBL 371 001 R A 63-30-00 00 1SBL 371 001 R TA 75 DU 00 1SAZ 321 201 R10 VE 5-2 BED 50 63 70 63 A 50-30-00 1SBL 351 001 R A 75-30-00 00 1SBL 411 001 R A 75-30-00 00 1SBL 411 001 R TA 75 DU 00 1SAZ 321 201 R10 VE 5-2 BED 75 75 75 90 A 75-30-00 1SBL 411 001 R A 95-30-00 00 1SFL 431 001 R A 95-30-00 00 1SFL 431 001 R TA 110 DU 00 1SAZ 411 201 R10 VE 5-2 BED 95 90 100 132 A 95-30-00 1SFL 431 001 R A 110-30-00 00 1SFL 451 001 R A 110-30-00 00 1SFL 451 001 R TA 110 DU 00 1SAZ 411 201 R10 VE 5-2 BED 110 (1) The setting current value is: nominal motor current x 0.58 Ordering Details - Main Accessories Description Rated control voltage Uc Connection sets Auxiliary contact blocks Interlock units Electronic timers Mounting plate 24 V a.c./d.c. 110 ... 120 V a.c. 220 ... 240 V a.c. 380 ... 440 V a.c. Type Order Code Packing pieces Weight kg BEY 16V-1 BEY 26-1 BEY 40-1 BED 50 BED 75 BED 95 BED 110 CA 5-10 CA 5-01 VE 5-1 VE 5-2 TE5S-24 TE5S-120 TE5S-240 TE5S-440 PN 110-41 1SBN 081 413 R1001 1SBN 082 413 R1000 1SBN 082 813 R1000 1SBN 083 503 R1000 1SBN 084 103 R1000 1SFN 084 303 R1000 1SFN 084 503 R1000 1SBN 010 010 R1010 1SBN 010 010 R1001 1SBN 030 110 R1000 1SBN 030 210 R1000 1SBN 020 010 R1001 1SBN 020 010 R1002 1SBN 020 010 R1003 1SBN 020 010 R1004 1SFN 094 303 R1000 1 1 1 1 1 1 1 10 10 1 1 1 1 1 1 1 0.045 0.060 0.060 0.280 0.250 0.400 0.500 0.014 0.014 0.076 0.146 0.080 0.080 0.080 0.080 0.950 39 1SBC101001C0201 Direct-On-Line Starters Open Type Version in Kit Form Protection by Thermal Overload Relay O R KM1 40 1SBC101001C0201 96 13 I KM1 A1 A1 14 14 KM1 Remote Control Local Control KM1 E3034D Us N KM1 : 3/L2 A2 KM1 E2861D Us N KM1 : 3/L2 A2 M 3 I E2858D 6/T3 4/T2 2/T1 98 96 U1 V1 W1 13 O FR1 Power Circuit FR1 96 14 6/ T3 4/ T2 2/ T1 A2 R 97 O R FR1 95 R O 95 KM1 : 5/L3 Us 95 5/ L3 A1 KM1 : 5/L3 Us R 13 3/ L2 1/ L1 Wiring Diagrams for Direct-On-Line Starters Reversing Starters Open Type Version in Kit Form Protection by Thermal Overload Relay Wiring Diagram for Reversing Starters With or without VM 5-1 mechanical interlock unit, electrical interlocking by built-in or add-on auxiliary contacts. KM1 : 5/L3 KM1 : 5/L3 95 95 96 96 Power Circuit 13 14 21 21 21 KM1 22 A1 A1 22 22 Remote Control A2 KM2 E3036D Us N KM1 : 3/L2 A2 E3035D KM2 A2 KM1 A2 Us N KM1 : 3/L2 KM2 KM2 KM1 3 II 14 14 KM1 A1 22 A1 M I KM1 KM2 U1 V1 W1 13 13 13 21 E3039D 6/T3 4/T2 98 2/T1 R FR1 KM2 14 I FR1 96 O 13 14 KM1 97 R 95 O Us O II R R 5/ L3 21 3/ L2 1/ L1 O R FR1 22 6/ T3 4/ T2 2/ T1 14 A2 KM2 A1 13 5/ L3 21 22 6/ T3 4/ T2 2/ T1 A1 A2 KM1 3/ L2 1/ L1 Us Local Control Wiring Diagram for Reversing Starters With VE 5-.. mechanical and electrical interlock unit. KM1 : 5/L3 KM1 : 5/L3 95 96 FR1 Remote Control 01 02 A1 A1 A1 02 02 01 01 14 KM2 14 14 II KM2 A2 Us N KM1 : 3/L2 E3038D E3037D A2 A2 KM2 A2 KM1 KM1 Us N KM1 : 3/L2 KM1 13 13 13 13 14 02 A1 M I KM2 01 E3040D 6/T3 4/T2 2/T1 98 96 U1 V1 W1 Power Circuit R 96 13 14 6/ T3 4/ T2 KM1 I FR1 3 O O 97 R 95 O Us FR1 II R R 95 O R 5/ L3 3/ L2 1/ L1 A1 2/ T1 02 KM2 A2 01 01 02 14 13 5/ L3 6/ T3 4/ T2 2/ T1 A1 A2 KM1 3/ L2 1/ L1 Us Local Control 41 1SBC101001C0201 Star-Delta Starters Open Type Version in Kit Form Δ L Y Protection by Thermal Overload Relay Star KM2 - Delta KM3 - Line KM1 Mounting A1 15 23 5/ L3 A1 13 3/ L2 1/ L1 5/ L3 1/ L1 3/ L2 R A2 t1+t2 18 16 24 14 6/ T3 4/ T2 2/ T1 A2 O 95 R t1 97 6/ T3 4/ T2 A2 02 02 14 6/ T3 4/ T2 2/ T1 A2 KT KM1 2/ T1 KM3 KM2 A1 01 01 5/ L3 A1 13 3/ L2 1/ L1 Wiring Diagram - Star-Delta Starters 7.5 ... 90 kW - 400 V AC-3 Star-Delta starters with interlock unit V2 U2 W2 V2 Power Circuit U2 KM3 : 5/L3 Us 6/T3 W1 M 3 V1 U1 E2862D W2 4/T2 2/T1 98 96 FR1 W1 M 3 V1 U1 KM3 : 5/L3 Us R O R 95 R 95 O FR1 96 96 96 FR1 I/0 23 23 0 KM1 KM1 I A1 Remote Control 42 1SBC101001C0201 Local Control 13 L E3042D KM1 A1 14 14 A1 02 KM3 Y A2 KM2 A2 A1 02 A1 14 L Us N KM3 : 3/L2 A2 KM1 E3041D Y 14 A1 02 KM3 KM2 KM1 A2 KM2 A2 Us N KM3 : 3/L2 A2 A1 02 KM2 KM1 13 t1+t2 A2 15 t1 01 18 01 16 13 13 t1+t2 KT A2 15 t1 01 18 01 16 KT A1 24 24 24 I Star-Delta Starters Open Type Version in Kit Form Δ L Y Protection by Thermal Overload Relay Star KM2 - Delta KM3 - Line KM1 Mounting A1 15 23 5/ L3 A1 13 3/ L2 1/ L1 5/ L3 21 1/ L1 3/ L2 R A2 t1+t2 18 16 24 14 6/ T3 4/ T2 2/ T1 A2 O 95 R t1 97 22 6/ T3 4/ T2 A2 22 14 6/ T3 4/ T2 2/ T1 A2 KT KM1 2/ T1 KM3 KM2 A1 21 5/ L3 A1 13 3/ L2 1/ L1 Wiring Diagram - Star-Delta Starters 7.5 ... 90 kW - 400 V AC-3 Star-Delta starters without interlock unit V2 U2 W2 V2 Power Circuit U2 V1 U1 W1 M 3 V1 U1 KM3 : 5/L3 Us R R O 95 O R 95 KM3 : 5/L3 Us 6/T3 W1 M 3 E3043D W2 4/T2 2/T1 98 96 FR1 96 96 FR1 96 FR1 I/0 23 23 0 KM1 KM1 Remote Control L KM2 13 13 A2 A1 KM1 A1 14 14 A1 22 KM3 Y KM2 KM1 A2 Us N KM3 : 3/L2 21 18 15 A1 22 KM2 A2 A1 14 14 KM3 t1+t2 A2 21 16 13 13 A2 KM1 t1 L E3045D Y KM2 KM1 E3044D KM3 KT A2 KM2 A2 Us N KM3 : 3/L2 A1 22 KM2 A1 22 KM3 t1+t2 21 18 15 t1 A2 21 16 KT A1 24 24 I 24 I Local Control 43 1SBC101001C0201 Star-Delta Starters Open Type Version in Kit Form Y L Δ Protection by Thermal Overload Relay Line KM1 - Delta KM3 - Star KM2 Mounting 3/ L2 5/ L3 4/ T2 6/ T3 14 13 1/ L1 2/ T1 A2 02 02 A1 01 01 5/ L3 6/ T3 4/ T2 2/ T1 A2 24 14 6/ T3 4/ T2 2/ T1 A2 97 R 95 O R KM2 KM3 A2 t1+t2 18 16 KM1 t1 3/ L2 1/ L1 A1 23 5/ L3 13 3/ L2 A1 15 KT A1 1/ L1 Wiring Diagram - Star-Delta Starters 7.5 ... 37 kW - 400 V AC-3 Star-Delta starters with interlock unit 6/T3 W1 V1 U1 W2 M 3 W1 V1 Power Circuit U1 W2 M 3 V2 U2 KM3 : 5/L3 Us R R O 95 O R 95 KM3 : 5/L3 Us V2 U2 E2863D 4/T2 2/T1 98 96 FR1 96 96 FR1 96 FR1 I/0 23 23 0 KM1 KM1 44 1SBC101001C0201 Y Local Control A1 A2 01 16 01 18 13 A1 02 A1 02 A1 14 KM3 L KM2 A2 KM1 A2 Us N KM3 : 3/L2 A2 14 A1 02 A2 KM2 Y E3048D L A2 A1 02 A1 14 KM3 E3047D Remote Control KM1 t1 KM2 KM1 A2 14 KM2 KM1 Us N KM3 : 3/L2 15 t1+t2 13 t1 01 16 01 18 13 13 t1+t2 KT A2 15 KT A1 24 24 I 24 I L Δ Star-Delta Starters Open Type Version in Kit Form Y Protection by Thermal Overload Relay Line KM1 - Delta KM3 - Star KM2 Mounting 21 22 5/ L3 14 13 3/ L2 6/ T3 1/ L1 4/ T2 2/ T1 A2 A1 5/ L3 21 22 6/ T3 4/ T2 2/ T1 A2 24 14 6/ T3 4/ T2 2/ T1 A2 97 R 95 O R KM2 KM3 A2 t1+t2 18 16 KM1 t1 3/ L2 1/ L1 A1 23 5/ L3 13 3/ L2 A1 15 KT A1 1/ L1 Wiring Diagram - Star-Delta Starters 7.5 ... 37 kW - 400 V AC-3 Star-Delta starters without interlock unit 6/T3 W1 V1 U1 W2 M 3 W1 V1 Power Circuit U1 U2 W2 M 3 V2 U2 KM3 : 5/L3 Us R O 95 O R R 95 KM3 : 5/L3 Us V2 E3046D 4/T2 2/T1 98 96 FR1 96 96 FR1 96 FR1 I/0 23 23 0 KM1 KM1 Remote Control Y A1 21 16 KM2 A2 A1 22 KM3 A1 22 A1 14 KM3 L A2 KM1 A2 14 Us N KM3 : 3/L2 A2 15 21 18 13 13 21 16 KM2 KM2 t1 Y E3050D L KM2 KM1 A1 22 KM3 A1 22 A1 14 KM3 t1+t2 E3049D KM1 A2 Us N KM3 : 3/L2 KM2 A2 14 KM2 KM1 t1 A2 21 18 13 13 t1+t2 KT A2 15 KT A1 24 24 I 24 I Local Control 45 1SBC101001C0201 A 9 ... A 16 3-pole Contactors Protected by Thermal Overload Relay Direct-On-Line and Reversing Starters Dimensions (in mm) 133 35 ø 4.5 (M4) 4 60 50 74 35 mm EN/IEC 60715 74 10 E0759D 4.5 4.5 E0101D 44 6 95 A 9, A 12, A 16 + TA 25 DU thermal O/L relay E0760D 14* 1 75 68 4 E2866D 4.5 60 50 35 mm EN/IEC 60715 134 ø 4.5 (M4) 12 5.5 35 59 4.5 A 9, A 12, A 16 + VM 5-1/VE 5-1 interlock unit + BER 16V connection set + TA 25 DU thermal O/L relay 6 95 E2867D 14* 1 75 68 4 95 A 9, A 12, A 16 + BER 16 connection set + TA 25 DU thermal O/L relay * For TA 25 DU 32 only 46 1SBC101001C0201 6 E2869D 1 14* E2868D 4.5 60 50 35 mm EN/IEC 60715 134 Ø 4.5 (M4) 12 5.5 35 44 4.5 E2870D 88 E0110D1 103 A 26 3-pole Contactor Protected by Thermal Overload Relay Direct-On-Line and Reversing Starters Dimensions (in mm) 93.6 147 E0765D ø 4.2 (M4) 80 70 4 35 mm EN/IEC 60715 90 45 10 4.5 4.5 E0117D 9 54 6 109.4 A 26 + TA 25 DU thermal O/L relay E0766D 14* 15.4 93.6 70 35 mm EN/IEC 60715 4 10 E2871D 4.5 45 69 4.5 E0126D 149 ø 4.2 (M4) 6.3 9 80 123 6 E2872D 14* 15.4 109.4 A 26 + VM 5-1/VE 5-1 interlock unit + BER 40V connection set + TA 25 DU thermal O/L relay 93.6 6.3 70 Ø 4.2 (M4) 4 10 54 4.5 109.4 6 E2874D A 26 + BER 40 connection set + TA 25 DU thermal O/L relay 45 15.4 14* E2873D 4.5 E2875D 149 35 mm EN/IEC 60715 9 80 108 * For TA 25 DU 32 only 47 1SBC101001C0201 A 30 and A 40 3-pole Contactors Protected by Thermal Overload Relay Direct-On-Line and Reversing Starters Dimensions (in mm) 108.3 70 90 35 mm EN/IEC 60715 10 4.5 4.5 6 14* 9.7 103.7 A 30, A 40 + TA 25 DU thermal O/L relay 108.3 ø 4.2 (M4) 6 103.7 A 30, A 40 + VM 5-1/VE 5-1 interlock unit + BER 40V connection set + TA 25 DU thermal O/L relay 69 4.5 108.3 6.3 9.7 14* E2878D 4.5 103.7 6 E2879D 155 70 10 4 A 30, A 40 + BER 40 connection set + TA 25 DU thermal O/L relay 80 Ø 4.2 (M4) 35 mm EN/IEC 60715 9 45 54 4.5 E2875D 108 1SBC101001C0201 45 9.7 14* E2876D 4.5 E2877D 155 70 10 4 48 80 6.3 35 mm EN/IEC 60715 9 E0126D 123 * For TA 25 DU 32 only E0772D E0771D 149.5 4 ø 4.2 (M4) 80 45 9 E0117D 54 A 30 and A 40 3-pole Contactors Protected by Thermal Overload Relay Direct-On-Line and Reversing Starters Dimensions (in mm) 108.3 45 70 4 ø 4.2 (M4) 4.5 4.5 6 1.8 112.8 A 30, A 40 + TA 42 DU thermal O/L relay E0117D 10 E0774D E0773D 155.5 90 35 mm EN/IEC 60715 9 80 54 108.3 ø 4.2 (M4) 70 6.3 4 10 6 1.8 45 69 4.5 E2881D E2880D 4.5 E0126D 161 35 mm EN/IEC 60715 9 80 123 112.8 A 30, A 40 + VM 5-1/VE 5-1 interlock unit + BER 40V connection set + TA 42 DU thermal O/L relay 108.3 6.3 70 Ø 4.2 (M4) 4 10 A 30, A 40 + BER 40 connection set + TA 42 DU thermal O/L relay 6 1.8 112.8 45 54 4.5 E2883D E2882D 4.5 E2875D 161 35 mm EN/IEC 60715 9 80 108 49 1SBC101001C0201 Star-Delta Starters Protected by Thermal Overload Relay Δ L Y Star Delta Line Mounting Dimensions (in mm) 100.5 Dim A 12 60 4 Dim C 35 4.5 E2885D ø 4.5 (M4) 4.5 50 35 mm EN/IEC 60715 134.5 138.5 85 75.5 5.5 BEY 16-1 6 95 E2886D 1 Dim A Dim B Dim C 155 132 44 E2887D Dim B 44 BEY 16V-1 + VE 5-1 170 147 59 Star KM2, Delta KM3, Line KM1 mounting type: A9 - A9 - A9, A9 - A12 - A12, A12 - A16 - A16 with or without VE 5-1 interlock unit + BEY 16..-1 connection set + TA 25 DU thermal O/L relay + TE5S electronic Timer Dim A 119.8 Dim B 9 Ø 4.2 (M4) 35 4.5 Dim C 45 BEY 26-1 15.4 6 109.4 Dim A Dim B Dim C 175 152 44 54 BEY 26-1 + VE 5-1 190 167 59 Star KM2, Delta KM3, Line KM1 mounting type: A16 - A26 - A26 with or without VE 5-1 interlock unit + BEY 26-1 connection set + TA 25 DU thermal O/L relay + TE5S electronic timer 50 1SBC101001C0201 80 E2890D 4.5 5.5 70 60 10 50 4 E2889D E2888D 149 108 35 mm EN/IEC 60715 Ø 4.5 (M4) Star-Delta Starters Protected by Thermal Overload Relay Δ L Y Star Delta Line Mounting Dimensions (in mm) Dim A 134.5 E2892D 6 80 BEY 40-1 9.7 14* E2891D 45 Dim A Dim B Dim C 185 162 54 E2893D 4.5 Dim C 103.7 70 155 115 35 mm EN/IEC 60715 10 4 80 Ø 4.2 (M4) 9 70 Dim B 54 BEY 40-1 + VE 5-1 200 177 69 Star KM2, Delta KM3, Line KM1 mounting type: A26 - A30 - A30 with or without VE 5-1 interlock unit + BEY 40-1 connection set + TA 25 DU thermal O/L relay + TE5S electronic timer * For TA 25 DU 32 only. Dim A 134.5 Dim B Ø 4.2 (M4) 9 4 4.5 Dim C 45 6 1.8 112.8 E2895D E2894D BEY 40-1 Dim A Dim B Dim C 185 162 54 54 E2893D 161 115 35 mm EN/IEC 60715 10 BEY 40-1 + VE 5-1 200 177 69 Star KM2, Delta KM3, Line KM1 mounting type: A26 - A40 - A40 with or without VE 5-1 interlock unit + BEY 40-1 connection set + TA 42 DU thermal O/L relay + TE5S electronic timer 51 1SBC101001C0201 Star-Delta Starters Protected by Thermal Overload Relay Δ L Y Star Delta Line Mounting Dimensions (in mm) 231.5 E2897D E2896D 120.5 35 mm EN/IEC 60715 76.5 133.9 Star KM2, Delta KM3, Line KM1 mounting type: A30 - A50 - A50, A40 - A63 - A63 + VE 5-2 interlock unit + BED 50 connection set + TA 75 DU thermal O/L relay + TE5S electronic timer 90 45 24.5 60 10 60 5 E3023D 4.5 100 ø 6.2 (M6) 70 80 ø 4.2 (M4) Star KM2, Delta KM3, Line KM1 mounting type: A30 - A50 - A50, A40 - A63 - A63 Drilling plan 52 1SBC101001C0201 Star-Delta Starters Protected by Thermal Overload Relay Δ L Y Star Delta Line Mounting Dimensions (in mm) 247.5 E2899D E2898D 120.5 35 mm EN/IEC 60715 76.5 133.9 Star KM2, Delta KM3, Line KM1 mounting type: A50 - A75 - A75 + VE 5-2 interlock unit + BED 75 connection set + TA 75 DU thermal O/L relay + TE5S electronic timer 60 25 60 10 60 5 E3024D 90 5 100 ø 6.2 (M6) Star KM2, Delta KM3, Line KM1 mounting type: A50 - A75 - A75 Drilling plan 53 1SBC101001C0201 Δ L Star-Delta Starters Protected by Thermal Overload Relay Y Star Delta Line Mounting Dimensions (in mm) 335 123.5 6.5 272 163 175 300 20 E2900D 6 E3001D 5 141.8 Star KM2, Delta KM3, Line KM1 mounting type: A75 - A95 - A95 without VE5-2 interlock unit + BED 95 connection set + TA 110 DU thermal O/L relay + TE5S electronic timer 345.5 123.5 300 272 175 163 6.5 20 5 141.8 E3003D E3002D 6 Star KM2, Delta KM3, Line KM1 mounting type: A95 - A110 - A110 without VE5-2 interlock unit + BED 110 connection set + TA 110 DU thermal O/L relay + TE5S electronic timer 54 1SBC101001C0201 L Δ Star-Delta Starters Protected by Thermal Overload Relay Y Line Delta Star Mounting Dimensions (in mm) 100.5 Dim A Dim B 12 ø 4.5 (M4) BEY 16-2 6 95 Dim A Dim B Dim C E3005D 1 155 132 44 Dim C 35 60 E3006D 4 44 E3004D 4.5 50 35 mm EN/IEC 60715 134.5 138.5 75.5 85 5.5 4.5 BEY 16V-2 + VE 5-1 170 147 59 Line KM1, Delta KM3, Star KM2 mounting type: A9 - A9 - A9, A12 - A12 - A9, A16 - A16 - A12 with or without VE 5-1 interlock unit + BEY 16..-2 connection set + TA 25 DU thermal O/L relay + TE5S electronic timer Dim A 119.8 Dim B 9 Ø 4.2 (M4) 4.5 45 54 BEY 26-2 15.4 6 109.4 Dim A Dim B Dim C 175 152 44 35 Dim C 4.5 E3009D 50 10 60 70 80 4 E3008D E3007D 149 108 35 mm EN/IEC 60715 Ø 4.5 (M4) BEY 26-2 + VE 5-1 190 167 59 Line KM1, Delta KM3, Star KM2 mounting type: A26 - A26 - A16 with or without VE 5-1 interlock unit + BEY 26-2 connection set + TA 25 DU thermal O/L relay + TE5S electronic timer 55 1SBC101001C0201 L Δ Star-Delta Starters Protected by Thermal Overload Relay Y Line Delta Star Mounting Dimensions (in mm) Dim A 134.5 Ø 4.2 (M4) 70 80 10 4 4.5 BEY 40-2 9.7 6 Dim A Dim B Dim C E3011D 14* E3010D 54 103.7 185 162 54 45 Dim C E3012D 155 115 35 mm EN/IEC 60715 9 Dim C E3012D Dim B BEY 40-2 + VE 5-1 200 177 69 Line KM1, Delta KM3, Star KM2 mounting type: A30 - A30 - A26 with or without VE 5-1 interlock unit + BEY 40-2 connection set + TA 25 DU thermal O/L relay + TE5S electronic timer * TA 25 DU 32 only Dim A 134.5 Dim B 9 161 70 80 115 35 mm EN/IEC 60715 Ø 4.2 (M4) 10 4.5 6 1.8 112.8 BEY 40-2 E3014D E3013D 54 Dim A Dim B Dim C 185 162 54 45 BEY 40-2 + VE 5-1 200 177 69 Line KM1, Delta KM3, Star KM2 mounting type: A40 - A40 - A26 with or without VE 5-1 interlock unit + BEY 40-2 connection set + TA 42 DU thermal O/L relay + TE5S electronic timer 56 1SBC101001C0201 Main Accessories Ordering Details Auxiliary Contact Blocks Positioning Mounting Contacts Type Order code Packing Weight piece kg CA 5-10 CA 5-01 1SBN 010 010 R1010 1SBN 010 010 R1001 10 10 0.014 0.014 on : 1 - SB8099C2 SB7375C2 Front mounting A 9...A 110 CAL 5-11 CA 5-10 Side mounting A 9...A 75 1 1 CAL 5-11 1SBN 010 020 R1011 2 0.050 A 95...A 110 1 1 CAL 18-11 1SFN 010 720 R1011 2 0.050 Electronic Timers for star-delta starters (dwelling time 50 ms) Mounting Timing range Direct Independent 0.8...8 s or 6...60 s SB7558C2 1 { Supply voltage Type Order code 24 a.c. / d.c. 110 ... 120 a.c. 220 ... 240 a.c. 380 ... 440 a.c. TE5S-24 TE5S-120 TE5S-240 TE5S-440 1SBN 020 010 R1001 1SBN 020 010 R1002 1SBN 020 010 R1003 1SBN 020 010 R1004 Packing Weight piece 1 1 1 1 kg 0.080 0.080 0.080 0.080 Interlock Units for two horizontal mounted contactors Feature TE5S For contactor combination: Contacts Type Order code Packing Weight piece A 9...A 40 A 9...A 40 kg - 2 VE 5-1 1SBN 030 110 R1000 1 0.076 Mech. / elec. A 30...A 40 A 50...A 75 A 50...A 110 A 50...A 110 2 VE 5-2 1SBN 030 210 R1000 1 0.146 Mechanical - VM 5-1 1SBN 030 100 R1000 1 0.066 A 9...A 40 A 9...A 40 - SB7282C2 LK.. Terminals for control lead connections Connection Type Order code Right and left on A 45 ... A 75 LK 75-L 1SBN 073 552 R1003 2 0.006 Opposite on A 45 ... A 75 LK 75-F 1SBN 073 552 R1002 2 0.006 Right and left on A 95 ... A 110 LK 110 1SFN 074 352 R1000 2 0.010 1SB5 7282 3F0301 VE 5-1 Packing Weight pieces kg 1 piece LD.. Additional Terminal Blocks For contactors Type Order code A 9 ... A 16 LD 16 1SBN 071 408 R1000 2 0.030 A 26 LD 26 1SBN 072 408 R1000 2 0.040 A 30 ... A 40 LD 40 1SBN 072 808 R1000 1 0.075 A 45 ... A 75 LD 75 1SBN 073 508 R1000 1 0.115 A 95 ... A 110 LD 110 1SFN 074 308 R1000 1 0.150 1SBC5 7282 2F0301 LK 75-F Packing Weight pieces kg 1 piece Note: BEY, BED, BER and BEM connection sets can no longer be used with LD.. additional terminal blocks LW.. Enlargement Pieces For contactors LD 16 bar mm 6.5 15 x 3 Type Order code LW 110 1SFN 074 307 R1000 Packing Weight set kg 1 set 1 0.100 1SFT98000-011C3 A 95, A 110 Dimensions hole Ø mm LW.. For other accessories, see the main catalogue. 57 1SBC101001C0201 Connecting Links, Connection Sets and Mounting Plates For Direct-On-Line and Reversing Starters 1SBC5 8281 3F0301 Ordering Details Connecting links 1SBC5 8276 3F0301 BEA 16/116 BEA 40/450 For contactors For manual motor starter Type Order code Packing Weight piece kg 1 piece A 9, A 12, A 16 A 26 MS 116 MS 116 BEA 16/116 BEA 26/116 1SBN 081 406 R1000 1SBN 082 406 R1000 10 10 0.020 0.024 A 9, A 12, A 16 A 26 MS 325 MS 325 BEA 16/325 BEA 26/325 1SBN 081 406 R1001 1SBN 082 406 R1001 10 10 0.031 0.031 A 30, A 40 A 50 MS 450 MS 450 BEA 40/450 BEA 50/450 1SBN 083 206 R1000 1SBN 083 506 R1000 1 1 0.061 0.062 A 50, A 63, A 75 A 95, A 110 MS 495 MS 495 BEA 75/495 BEA 110/495 1SBN 084 106 R1000 1SBN 084 506 R1000 1 1 0.120 0.124 For manual motor starter Type Order code Packing Weight piece kg 1 piece MS 325 BSA 325 FPTN 472 772 R0001 1 For manual motor starter Type Order code Packing Weight piece kg 1 piece Connection kit I (A) 25 A 0.009 Mounting plates 1SBC5 9080 3F0302 1SBC5 9078 3F0302 For contactors PM 26-13 1 x A 26 MS 116 MS 325 PM 26-13 1SBN 092 406 R1000 2 0.160 2 x A 9 ... A 26 MS 116 MS 325 PM 26-23 1SBN 091 407 R1000 1 0.330 PM 26-23 Connection sets for reversing contactors A2 1 3 5 1 3 5 2 4 6 2 4 6 Description BER 16V, BER 16, BER 40V, BER 40 BEM 75-30 ... BEM 110-30 A1 A2 E0744D A1 BER and BEM connection sets – 1 upstream and 1 downstream insulated, solid copper bars – 3 upstream and 3 downstream insulated, solid copper bars Note: For BER.. connection sets, Rated Insulation Voltage Ui = 690 V. For reversing starters with interlock unit Mounting on 3-pole contactors Interlock unit type Type Order code Packing Weight piece kg 1 piece 2 x A 9 ... A 16 VM / VE 5-1 BER 16V 1SBN 081 411 R1000 1 0.045 2 x A 26 2 x A 30, A 40 VM / VE 5-1 BER 40V 1SBN 082 411 R1000 1 0.085 2 x A 50 ... A 75 VE 5-2 BEM 75-30 1SBN 083 501 R1000 1 0.243 2 x A 95 ... A 110 VE 5-2 BEM 110-30 1SFN 084 301 R1000 1 0.450 Note: The connections provided for the A.. contactors can be used for the AF, AL, AL..Z, TAL, AE and TAE types. For reversing starters without interlock unit E0618D1 BER 16V BEM 75-30 58 1SBC101001C0201 Mounting on 3-pole contactors Type Order code Packing Weight piece kg 1 piece 2 x A 9 ... A 16 BER 16 1SBN 081 411 R1001 1 0.040 BER 40 1SBN 082 411 R1001 1 0.080 2 x A 26 2 x A 30, A 40 Note: The connections provided for the A.. contactors can be used for the AL, AL..Z and TAL types. Connection Sets for Star-Delta Starters Description 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 E3016D A1 A2 BEY 16..-1 BEY 26-1, BEY 40-1 BED 50.., BED 75.., BED 95, BED 110 BEY..-1 and BED connection sets – Insulated solid copper bars. – Insulated solid copper bars and insulated flexible copper wires. – Insulated solid copper bars. These connection sets are designed for Star-Delta starters whose contactors are assembled according to Star Delta Line mounting. They are made up of: – Star contactor: upstream Star point – Star contactor / Delta contactor: downstream connection in parallel – Delta contactor / Line contactor : upstream connection in parallel. BEY 16-1, BED 50-1 and BED 75-1 connection sets are designed for star and delta contactors without mechanical interlocking (contactor mounting joined side by side). For mechanically interlocked star and delta contactors, use BEY 16V-1, BED 50 and BED 75. 1SB500048F0000 BEY 26-1, BEY 40-1, BED 95 and BED 110 are designed for both star and delta contactors with or without interlock unit. Note: For BEY.. connection sets, Rated Insulation Voltage Ui = 690 V. Ordering Details 1SB500060F0000 BEY 16-1 BEY 26-1 For contactor Star Delta Line A9 A9 A 12 A9 A 12 A 16 A9 A 12 A 16 A 16 A 26 A 26 A 26 A 30 A 30 – A 26 A 40 A 40 VE 5-1 A 30 A 50 A 50 A 40 A 63 A 63 A 50 A 75 A 75 A 75 A 95 A 95 A 95 A 110 A 110 Interlock unit type Type Order code – BEY 16-1 1SBN 081 413 R1000 1 0.040 VE 5-1 BEY 16V-1 1SBN 081 413 R1001 1 0.045 BEY 26-1 1SBN 082 413 R1000 1 0.060 BEY 40-1 1SBN 082 813 R1000 1 0.060 – BED 50-1 1SBN 083 503 R1001 1 0.180 – VE 5-1 Packing Weight piece kg VE 5-2 BED 50 1SBN 083 503 R1000 1 0.280 – BED 75-1 1SBN 084 103 R1001 1 0.180 VE 5-2 BED 75 1SBN 084 103 R1000 1 0.250 BED 95 1SFN 084 303 R1000 1 0.400 BED 110 1SFN 084 503 R1000 1 0.500 – VE 5-2 – VE 5-2 Note: The connections provided for the A.. contactors can be used for the AL, AL..Z, AE and TAE types. A2 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 A1 A2 1 3 5 2 4 6 BEY..-2 connection sets Variant for Star-Delta Starters 7.5 kW up to 37 kW - 400 V E3015D A1 BEY 16..-2 BEY 26-2, BEY 40-2 – Insulated solid copper bars. – Insulated solid copper bars and insulated flexible copper wires 1SB500049F0000 These connection sets are designed for Star-Delta starters whose contactors are assembled according to Line Delta Star mounting. They are made up of: – Line contactor / Delta contactor: upstream connection phase-to-phase – Delta contactor / Star contactor: downstream connection in parallel – Star contactor: upstream Star point BEY 16-2 BEY 16-2 connection set is designed for star and delta contactors without mechanical interlocking (contactor mounting joined side by side). For mechanically interlocked star and delta contactors, use BEY 16V-2. BEY 26-2 and BEY 40-2 are designed for both star and delta contactors with or without interlock unit (contactor mounting joined side by side). Note: For BEY.. connection sets, Rated Insulation Voltage Ui = 690 V. 1SB500060F0000 Ordering Details BEY 40-2 For contactor Line Delta Star Interlock unit type Type Order code Packing Weight piece kg A9 A 12 A 16 A9 A 12 A 16 A9 A9 A 12 – BEY 16-2 1SBN 081 413 R2000 1 0.040 VE 5-1 BEY 16V-2 1SBN 081 413 R2001 1 0.045 A 26 A 26 A 16 BEY 26-2 1SBN 082 413 R2000 1 0.060 A 30 A 30 A 26 – A 40 A 40 A 26 VE 5-1 BEY 40-2 1SBN 082 813 R2000 1 0.060 – VE 5-1 Note: The connections provided for the A.. contactors can be used for the AL, AL..Z types. 59 1SBC101001C0201 ABB Entrelec Export Department 10, rue Ampère Z.I. - B.P. 114 F-69685 Chassieu cedex / France Tel. : +33 (0) 4 7222 1722 Fax : +33 (0) 4 7222 1935 1SBC 101 001 C0201 Printed in France (W 06.2006 xx) As part of its on-going product improvement, ABB reserves the right to modify the characteristics or the products described in this document. The information given is not-contractual. For further details please contact the ABB company marketing these products in your country.