Pacemaker Function and Programming
Transcription
Pacemaker Function and Programming
Pacemakers Basic Interrogation & Programming Steps Jonathan Ho, MD Assistant Clinical Professor D Department t t off Anesthesiology A th i l David Geffen School of Medicine at UCLA Disclosures none Initial steps Tools Menu Educational Materials Demos Select Zephry DR 5826 Pacemaker Initial Interrogation Screen Pacemaker Objectives Identify the atrial and ventricular signals on the programmers display. Illustrate atrial and ventricular sensed or paced p beats/signals on the programmer. Identify devices following interrogation; identify key features such as current pacing mode,, batteryy life,, history, y, thresholds,, etc. Identify programmed pacing rates briefly p g the LRL,, URL etc. explaining Bradytherapy Settings Pacemaker Objectives Demonstrate changing the pacing mode from DDD or VVI etc to an asynchronous (AOO/DOO) mode. Demonstrate how to change h the h rate. D Demonstrate h how to change pulse amplitude. Id tif rate Identify t adaptive d ti feature f t settings. tti Demonstrate how to turn off the rate adaptive feature feature. Demonstrate magnet response behavior of the device. Mode, Sensor, and Magnet Pacing mode Rate Settings Adjusting Pulse Amplitude Pacemaker Objectives Demonstrate how to interrogate underlying rhythm (or the presence/absence of one) using g specific p p programmers. g Briefly identify other advanced featuresspecial algorithms that should be preferably turned off before surgery. Rest rate, hysteresis y Rate Adaptive Features Testing Underlying Rhythm End session and select next device ICDs Basic Interrogation & Programming Steps Initial steps Tools Menu Educational Materials Demos Select Atlas II+ HF V V-365 365 ICD Initial Interrogation Screen ICD Objectives Identify the settings and therapy history for an ICD. Demonstrate how to deactivate the ICD two ways. One Step Option: Touch “Tachytherapy y py is enabled” button on initial screen to bring up option to disable tachy therapy Re-enable using same button. ICD Objectives: deactivate the ICD B Disabling By Di bli d detection: t ti Enter “Parameters” and use the “Tachy” tab to bring up “Zone Zone Configuration Configuration” Touch “Zone Configuration” and change from “3 zones” to “off” zones off Select “Program” and confirm Re-enable using g “Restore Last Settings” g Disabling tachyarrhythmia therapy: py One step p option p Disabling tachyarrhythmia therapy: Disabling detection through tachytherapy settings Disabling tachyarrhythmia therapy: py Zone configuration g to Off Tachy Therapy Disabled Restore VT/VF detection