Quick Installation Guide

Transcription

Quick Installation Guide
JetNet 5710G
Industrial 8PoE +2G Managed High Power
IEEE802.3at PoE Switch
Quick Installation Guide
V1.1
www.korenix.com
Introduction
JetNet 5710G, the revolutionary Gigabit Managed Industrial PoE Switch, is designed
exclusively for highly critical PoE applications such as real time IP video surveillance with
high resolution quality and the evolving demands of wireless communications such as Wimax
and 802.11 a/b/g/n Access Points. By software configuration or by LLDP auto detection, the
8 10/100 TX PoE injector ports can deliver 15.4W by IEEE 802.3af or 30W by the latest High
Power PoE IEEE 802.3at standard. The total power budget is up to 200W per unit to fulfill
local increasing PoE demands. The two Gigabit Ethernet ports provide high speed uplink
to connect with higher level backbone switches with Korenix MSR
technology. Korenix RSR
TM
TM
network redundancy
can recover the network failure in less than 5 ms. JetNet 5710G
is compliant with the EMC requirements of EN 50121-3-2 railway standard and has -40~70oC
wide operating temperature range to work under vibrating and shock environments in rolling
stock applications.
This document will give you a brief introduction of device installation and powering. For more
detailed instructions, please download user manual from Korenix web site at www.korenix.
com.
Package Checklist
Unpack the box and you will find
JetNet 5710G
Industrial 8PoE +2G Managed High Power
IEEE802.3at PoE Switch
Quick Installation Guide
4JetNet 5710G
4Quick Installation Guide
4CD User Manual
4Wall /Panel Mounting kits with screw x 1 set
V1.0
www.korenix.com
Wall mounting the Unit
JetNet 5710G supports wall-mounting only. There are 6 screw holes on the rear side of the
JetNet 5710G for fixing the mounting plate. Use the screws from the package to lock the
plates as shown in the Figure-A and Figure-B.
Use appropriate screw with
4.2mm nut to lock the device on wall or panel where with good
heat dissipation.
Grounding JetNet 5710G
There is one grounding screw on the right side of JetNet
5710G. Connect the frame grounding of JetNet 5710G
to the grounding surface to ensure safety and prevent
noise for communication interference.
Chassis Earth Ground
Wiring the Power Inputs
1. Insert the positive and negative
wires into the V+ and V- contact
on the terminal block connector.
2. Tighten the wire-clamp screws
to prevent the power wires from
being loosened.
Notes: The recommended working voltage is DC48V (Input range: DC48~ 57V),
maximum system power consumption will be 250 watts with 8 port 30W PD loading.
Wiring the Relay Output (DO)
The relay output contacts are in the
bottom side as shown in Figure-C.
The relay output (DO) is controlled
Relay carry
current 1A/
DC 24V
Extra alarm
power source
by the pre-defined operating rules.
To activate relay output function,
please refer to the User’s Manual for
Alert
Device
Dry Relay Alarm Output
Simulate Diagram
a detailed Relay Output information.
Earth Ground
Note: The relay contact only supports 1A current, DC 24V. It is not recommended to
apply higher voltage and current that exceeds these specifications.
Connecting to Network
1. Connecting the Ethernet Port: Connect the Ethernet port of JetNet 5710G with the
other Ethernet device by Cat-5/Cat-6 UTP or STP cable, and then the LNK/ACT LED will
turn on and start flashing to indicate that the communication is occurred between 2 devices.
Device Management
JetNet 5710G Industrial Managed Switch provides both in-band and out-band configuration
methods. You can configure the switch via the RS232 console with the attached console
cable. Or you can remotely manage the switch via network, using Telnet/SSH or Web/
HTTPS management.
1. Preparation for Console Management: Attach the RS-232 DB9 connector to your PC’s
COM port. Connect the RJ-45 connector to the console port of the JetNet 5710G.
Go to Start -> Program -> Accessories -> Communication -> Hyper Terminal.
Give a name to the new console connection.
Choose the COM name, and select the correct serial settings. The serial port settings of
JetNet 5710G are as below: 9600bps, No parity check, 8 Data bits, 1 stop bit
After connected, you will see the Switch login request. Type the username and password to
login. The default username is “admin”, password is “admin”.
Follow the manual to configure the software features.
2. Preparation for Web Management:
Before you attempt to use the embedded web
interface to manage switch operation, verify
that JetNet 5710G is properly installed on your
network and that every PC on this network
can access the switch via the web browser.
Launch the web browser (Internet Explorer or
Mozilla Firefox) on the PC.
Type http://5710G_IP_Address (The default IP address is 192.168.10.1.), then press Enter.
The login screen will appear next.
Type in the user name and password and click “OK” button. The welcome page of the WebBased management interface will appear shortly. The default user name and password is
admin/admin
At the left column of the web management
interface are listed the software features.
Ring column will list the available settings.
For more detailed instructions, please refer
to the Users’ manual of JetNet 5710G
included in the packing or download it from
the Korenix Web site at www.korenix.com.
Korenix Customer Service
KoreCARE is Korenix Technology’s global service center, where our professional staffs are
ready to answer your questions at any time.
Korenix global service center’s e-mail is [email protected]
Tel:+886-2-89111000
Fax:+886-2-29123328
Business service:[email protected]
Customer service:[email protected]
CPQ000N5710001